WorldWideScience

Sample records for sources ii

  1. RTNS-II [Rotating Target Neutron Source II] operational summary

    International Nuclear Information System (INIS)

    Heikkinen, D.W.

    1988-09-01

    The Rotating Target Neutron Source II facility (RTNS-II) operated for over nine years. Its purpose was to provide high intensities of 14 MeV neutrons for materials studies in the fusion energy program. For the period from 1982-1987, the facility was supported by both the US (Department of Energy) and Japan (Ministry of Education, Culture, and Science). RTNS-II contains two accelerator-based neutron sources which use the T(d,n) 4 He reaction. In this paper, we will summarize the operational history of RTNS-II. Typical operating parameters are given. In addition, a brief description of the experimental program is presented. The current status and future options for the facility are discussed. 7 refs., 5 tabs

  2. Searching for Compact Radio Sources Associated with UCH ii Regions

    Energy Technology Data Exchange (ETDEWEB)

    Masqué, Josep M.; Trinidad, Miguel A.; Rodríguez-Rico, Carlos A. [Departamento de Astronomía, Universidad de Guanajuato, Apdo. Postal 144, 36000 Guanajuato, México (Mexico); Rodríguez, Luis F.; Kurtz, Stan; Loinard, Laurent [Instituto de Radioastronomía y Astrofísica, Universidad Nacional Autónoma de México, Morelia 58089, México (Mexico); Dzib, Sergio A. [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany)

    2017-02-10

    Ultra-compact (UC)H ii regions represent a very early stage of massive star formation. The structure and evolution of these regions are not yet fully understood. Interferometric observations showed in recent years that compact sources of uncertain nature are associated with some UCH ii regions. To examine this, we carried out VLA 1.3 cm observations in the A configuration of selected UCH ii regions in order to report additional cases of compact sources embedded in UCH ii regions. With these observations, we find 13 compact sources that are associated with 9 UCH ii regions. Although we cannot establish an unambiguous nature for the newly detected sources, we assess some of their observational properties. According to the results, we can distinguish between two types of compact sources. One type corresponds to sources that are probably deeply embedded in the dense ionized gas of the UCH ii region. These sources are photoevaporated by the exciting star of the region and will last for 10{sup 4}–10{sup 5} years. They may play a crucial role in the evolution of the UCH ii region as the photoevaporated material could replenish the expanding plasma and might provide a solution to the so-called lifetime problem of these regions. The second type of compact sources is not associated with the densest ionized gas of the region. A few of these sources appear resolved and may be photoevaporating objects such as those of the first type, but with significantly lower mass depletion rates. The remaining sources of this second type appear unresolved, and their properties are varied. We speculate on the similarity between the sources of the second type and those of the Orion population of radio sources.

  3. Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

    International Nuclear Information System (INIS)

    Stohr, J.

    2011-01-01

    The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that LCLS-II only

  4. Linac Coherent Light Source II (LCLS-II) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Stohr, J

    2011-11-16

    The LCLS-II Project is designed to support the DOE Office of Science mission, as described in the 22 April 2010 Mission Need Statement. The scope of the Project was chosen to provide an increase in capabilities and capacity for the facility both at project completion in 2017 and in the subsequent decade. The Project is designed to address all points of the Mission Need Statement (MNS): (1) Expanded spectral reach; (2) Capability to provide x-ray beams with controllable polarization; (3) Capability to provide 'pump' pulses over a vastly extended range of photon energies to a sample, synchronized to LCLS-II x-ray probe pulses with controllable inter-pulse time delay; and (4) Increase of user access through parallel rather than serial x-ray beam use within the constraint of a $300M-$400M Total Project Cost (TPC) range. The LCLS-II Project will construct: (1) A hard x-ray undulator source (2-13 keV); (2) A soft x-ray undulator source (250-2,000 eV); (3) A dedicated, independent electron source for these new undulators, using sectors 10-20 of the SLAC linac; (4) Modifications to existing SLAC facilities for the injector and new shielded enclosures for the undulator sources, beam dumps and x-ray front ends; (5) A new experiment hall capable of accommodating four experiment stations; and (6) Relocation of the two soft x-ray instruments in the existing Near Experiment Hall (NEH) to the new experiment hall (Experiment Hall-II). A key objective of LCLS-II is to maintain near-term international leadership in the study of matter on the fundamental atomic length scale and the associated ultrafast time scales of atomic motion and electronic transformation. Clearly, such studies promise scientific breakthroughs in key areas of societal needs like energy, environment, health and technology, and they are uniquely enabled by forefront X-ray Free Electron Laser (X-FEL) facilities. While the implementation of LCLS-II extends to about 2017, it is important to realize that

  5. Improved selection criteria for H II regions, based on IRAS sources

    Science.gov (United States)

    Yan, Qing-Zeng; Xu, Ye; Walsh, A. J.; Macquart, J. P.; MacLeod, G. C.; Zhang, Bo; Hancock, P. J.; Chen, Xi; Tang, Zheng-Hong

    2018-05-01

    We present new criteria for selecting H II regions from the Infrared Astronomical Satellite (IRAS) Point Source Catalogue (PSC), based on an H II region catalogue derived manually from the all-sky Wide-field Infrared Survey Explorer (WISE). The criteria are used to augment the number of H II region candidates in the Milky Way. The criteria are defined by the linear decision boundary of two samples: IRAS point sources associated with known H II regions, which serve as the H II region sample, and IRAS point sources at high Galactic latitudes, which serve as the non-H II region sample. A machine learning classifier, specifically a support vector machine, is used to determine the decision boundary. We investigate all combinations of four IRAS bands and suggest that the optimal criterion is log(F_{60}/F_{12})≥ ( -0.19 × log(F_{100}/F_{25})+ 1.52), with detections at 60 and 100 {μ}m. This selects 3041 H II region candidates from the IRAS PSC. We find that IRAS H II region candidates show evidence of evolution on the two-colour diagram. Merging the WISE H II catalogue with IRAS H II region candidates, we estimate a lower limit of approximately 10 200 for the number of H II regions in the Milky Way.

  6. Current status for TRR-II Cold Neutron Source

    International Nuclear Information System (INIS)

    Lee, C.H.; Guung, T.C.; Lan, K.C.; Wang, C.H.; Chan, Y.K.; Shieh, D.J.

    2001-01-01

    The Taiwan Research Reactor (TRR) project (TRR-II) is carrying out at Institute of Nuclear Energy Research (INER) from October 1998 to December 2006. The purpose of Cold Neutron Source (CNS) project is to build entire CNS facility to generate cold neutrons within TRR-II reactor. The objective of CNS design is to install CNS facility with a competitive brightness of cold neutron beam to other facilities in the world. Based on the TRR-II CNS project schedule, the conceptual design for TRR-II CNS facility has been completed and the mock-up test facility for full-scale hydrogen loop has been designed. (author)

  7. Research applications of the Livermore RTNS-II neutron sources

    International Nuclear Information System (INIS)

    Davis, J.C.

    1978-01-01

    The Lawrence Livermore Laboratory has completed construction of the Rotating Target Neutron Source-II (RTNS-II) Facility. These sources, built and operated for the Office of Fusion Energy of the Department of Energy, will be operated by LLL as a national facility for the study of materials damage processes induced by 14-MeV neutrons. Design strength of the sources is 4 x 10 13 n/s with a maximum flux of 1 X 10 13 n/cm 2 s. The 400 keV, 150 mA D + accelerators and 5000 rpm titanium--tritide target assemblies were built using experience gained with LLL's RTNS-I neutron source. The RTNS-I source, producing 6 x 10 12 n/s, is currently the most intense 14-MeV source available. RTNS-I has been used for fusion reactor materials studies for the past six years. The experimental program for the new sources will be oriented toward fundamental measurements of high energy neutron-induced effects. The data produced will be used to develop models of damage processes to help guide materials selection for future fusion reactors

  8. BEPC II positron source

    International Nuclear Information System (INIS)

    Pei Guoxi; Sun Yaolin; Liu Jintong; Chi Yunlong; Liu Yucheng; Liu Nianzong

    2006-01-01

    BEPC II-an upgrade project of the Beijing Electron Positron Collider (BEPC) is a factory type of e + e - collider. The fundamental requirements for its injector linac are the beam energy of 1.89 GeV for on-energy injection and a 40 mA positron beam current at the linac end with a low beam emittance of 1.6 μm and a low energy spread of ±0.5% so as to guarantee a higher injection rate (≥50 mA/min) to the storage ring. Since the positron flux is proportional to the primary electron beam power on the target, the authors will increase the electron gun current from 4A to 10A by using a new electron gun system and increase the primary electron energy from 120 MeV to 240 MeV. The positron source itself is an extremely important system for producing more positrons, including a positron converter target chamber, a 12kA flux modulator, the 7m focusing module with DC power supplies and the support. The new positron production linac from the electron gun to the positron source has been installed into the tunnel. In what follows, the authors will emphasize the positron source design, manufacture and tests. (authors)

  9. FRM-II research neutron source commissioned

    International Nuclear Information System (INIS)

    Anon.

    2004-01-01

    On March 2, 2004, the Heinz Maier-Leibnitz research neutron source (FRM-II) generated neutrons for the first time. This marked the most important step on the way to using FRM-II for scientific purposes. On this occasion, this unique research facility in the world was dedicated in a ceremony attended by approximately 1000 representatives of politics, industry, and science. The keynote speaker, Federal Minister of the Interior Otto Schily; Bavarian Minister President Edmund Stoiber; Professor Claus Weyrich (Member of the Executive Board of Siemens AG); Dr. Thomas Goppel (Bavarian State Minister for Science, Research, and Arts); Professor Wolfgang A. Herman (President of the Technical University of Munich); Hannelore Gabor (2nd Mayor of the host municipality of Garching); and Professor Winfried Petry (Scientific Director of FRM-II) underlined the great importance of FRM-II for science, research, medicine, and technology. FRM-II will not only fill the 'neutron gap', but create extremely brilliant working conditions thanks to its considerably higher neutron flux compared to that of its predecessor, the legendary Atomic Egg. After the first conceptual design studies starting in 1980, the ground breaking ceremony in August 1996, and the third partial permit issued at Easter of 2003, a unique tool is now available for modern science and for medical and technical applications. (orig.) [de

  10. Phase II beam lines at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1984-06-01

    The expansion of the National Synchrotron Light Source has been funded by the US Department of Energy. The Phase II program consists of both increased conventional facilities and six new beam lines. In this paper, an overview of the six beam lines which will be constructed during Phase II is presented. For five of the lines special radiation sources are necessary and the designs of four of the devices are complete. The relevant parameters of the insertion devices under construction and development are presented

  11. Ferroelectric plasma sources for NDCX-II and heavy ion drivers

    Energy Technology Data Exchange (ETDEWEB)

    Gilson, E.P., E-mail: egilson@pppl.gov [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Davidson, R.C.; Efthimion, P.C.; Kaganovich, I.D. [Princeton Plasma Physics Laboratory, Princeton University, P.O. Box 451, Princeton, New Jersey, 08543 (United States); Kwan, J.W.; Lidia, S.M.; Ni, P.A.; Roy, P.K.; Seidl, P.A.; Waldron, W.L. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California, 94720 (United States); Barnard, J.J.; Friedman, A. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California, 94550 (United States)

    2014-01-01

    A barium titanate ferroelectric cylindrical plasma source has been developed, tested and delivered for the Neutralized Drift Compression Experiment NDCX-II at Lawrence Berkeley National Laboratory (LBNL). The plasma source design is based on the successful design of the NDCX-I plasma source. A 7 kV pulse applied across the 3.8 mm-thick ceramic cylinder wall produces a large polarization surface charge density that leads to breakdown and plasma formation. The plasma that fills the NDCX-II drift section upstream of the final-focusing solenoid has a plasma number density exceeding 10{sup 10} cm{sup −3} and an electron temperature of several eV. The operating principle of the ferroelectric plasma source are reviewed and a detailed description of the installation plans is presented. The criteria for plasma sources with larger number density will be given, and concepts will be presented for plasma sources for driver applications. Plasma sources for drivers will need to be highly reliable, and operate at several Hz for millions of shots.

  12. Multi-Channel Tunable Source for Atomic Sensors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II SBIR will seek to develop a prototype laser source suitable for atomic interferometry from compact, robust, integrated components. AdvR's design is...

  13. Impedance-Source Networks for Electric Power Conversion Part II

    DEFF Research Database (Denmark)

    Siwakoti, Yam P.; Peng, Fang Zheng; Blaabjerg, Frede

    2015-01-01

    Impedance-source networks cover the entire spectrum of electric power conversion applications (dc-dc, dc-ac, ac-dc, ac-ac) controlled and modulated by different modulation strategies to generate the desired dc or ac voltage and current at the output. A comprehensive review of various impedance......-source-network-based power converters has been covered in a previous paper and main topologies were discussed from an application point of view. Now Part II provides a comprehensive review of the most popular control and modulation strategies for impedance-source network-based power converters/inverters. These methods...

  14. Concepts of UCN sources for the FRM-II

    CERN Document Server

    Trinks, U; Paul, S; Schott, W

    2000-01-01

    Three concepts for sources of ultra-cold neutrons (UCN) for the reactor FRM-II at Garching near Munich are studied: one, Mini-D sub 2 , is a source with 170 cm sup 3 of solid deuterium in the beam tube SR4 and the second one a large solid-deuterium source (volume about 30 dm sup 3), mounted in the beam tube SR5 as an advanced cold source with a number of neutron guides. The third one, Mark 3000, uses superfluid sup 4 He at a cold-neutron guide. A UCN density of up to 7x10 sup 4 cm sup - sup 3 may possibly be achieved in the storage volumes of Mini-D sub 2 yielding more than 10 sup 9 UCN for extraction to an attached experimental setup. The usable UCN flux at the periphery of the large deuterium source is predicted to be 2x10 sup 7 cm sup - sup 2 s sup - sup 1. Mark 3000, finally, is expected to yield a UCN density of about 10 sup 5 cm sup - sup 3.

  15. LEVIS lithium ion source experiments on PBFA-II

    International Nuclear Information System (INIS)

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Lopez, M.; Clark, B.F.; Schroeder, J.; Bailey, J.E.; Filuk, A.B.; Carlson, A.L.

    1992-01-01

    PBFA-II is a pulsed power generator designed to apply up to a 25 MV, 20 ns pulse to a focusing 15 cm-radius Applied-B ion diode for inertial confinement fusion applications. Several different approaches have been pursued to produce a high-purity (> 90%), high-current density (5--10 kA/cm 2 ) singly ionized lithium ion source for acceleration in this diode. In addition to having high source purity, such a source should be active, i.e. the ions should be produced before the power pulse arrives, to provide better electrical coupling from the accelerator to the diode. In the LEVIS (Laser EVaporation Ion Source) process, energy from two lasers impinges on a thin (500 nm) lithium or lithium-bearing film on an insulating substrate. The authors will discuss a new series of LEVIS experiments, with a number of improvements: (1) the laser distribution cone was redesigned, resulting in a more uniform illumination of the 4 cm-tall Li-producing surface; (2) the anode surface is being slow-heated to 120--150 C to help drive off contaminants; and (3) they have expanded the number of source and beam diagnostics

  16. Status of the FRM-II hot neutron source

    International Nuclear Information System (INIS)

    Mueller, C.; Gutsmiedl, E.

    2001-01-01

    The new research reactor FRM-II will be equipped with a hot neutron source. This secondary source will shift a part of the thermal neutron energy spectrum in the D 2 O moderator to energies from 0.1 to 1 eV. The hot neutron source consists of a graphite cylinder (200 mm diameter, 300 mm high), which is heated by gamma radiation up to a maximum temperature of about 2400 C. The graphite cylinder is surrounded by a high-temperature insulation of carbon fiber, to achieve this high temperature. We have accomplished mock-up tests of the carbon fiber in a high temperature furnace, to investigate the insulation properties of the material. The graphite cylinder and the insulation are covered with two vessels made out of Zircaloy 4. The space between the vessels is filled with helium. The hot neutron source is permanent under control by pressure and temperature measurements. The temperature inside the graphite cylinder will be measured by a purpose-built noise thermometer due to the extremely harsh environment conditions (temperature and nuclear radiation). The hot neutron source is designed and manufactured according to the general specification basic safety and to the German nuclear atomic rules (KTA). The source will be installed in year 2001. (orig.)

  17. SOURCE REGIONS OF THE TYPE II RADIO BURST OBSERVED DURING A CME–CME INTERACTION ON 2013 MAY 22

    International Nuclear Information System (INIS)

    Mäkelä, P.; Reiner, M. J.; Akiyama, S.; Gopalswamy, N.; Krupar, V.

    2016-01-01

    We report on our study of radio source regions during the type II radio burst on 2013 May 22 based on direction-finding analysis of the Wind /WAVES and STEREO /WAVES (SWAVES) radio observations at decameter–hectometric wavelengths. The type II emission showed an enhancement that coincided with the interaction of two coronal mass ejections (CMEs) launched in sequence along closely spaced trajectories. The triangulation of the SWAVES source directions posited the ecliptic projections of the radio sources near the line connecting the Sun and the STEREO-A spacecraft. The WAVES and SWAVES source directions revealed shifts in the latitude of the radio source, indicating that the spatial location of the dominant source of the type II emission varies during the CME–CME interaction. The WAVES source directions close to 1 MHz frequencies matched the location of the leading edge of the primary CME seen in the images of the LASCO/C3 coronagraph. This correspondence of spatial locations at both wavelengths confirms that the CME–CME interaction region is the source of the type II enhancement. Comparison of radio and white-light observations also showed that at lower frequencies scattering significantly affects radio wave propagation.

  18. Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX-II)

    International Nuclear Information System (INIS)

    Roy, P.K.; Greenway, W.; Kwan, J.W.; Seidl, P.A.; Waldron, W.

    2011-01-01

    To heat targets to electron-volt temperatures for the study of warm dense matter with intense ion beams, low mass ions, such as lithium, have an energy loss peak (dE/dx) at a suitable kinetic energy. The Heavy Ion Fusion Sciences (HIFS) program at Lawrence Berkeley National Laboratory will carry out warm dense matter experiments using Li + ion beam with energy 1.2-4 MeV in order to achieve uniform heating up to 0.1-1 eV. The accelerator physics design of Neutralized Drift Compression Experiment (NDCX-II) has a pulse length at the ion source of about 0.5 (micro)s. Thus for producing 50 nC of beam charge, the required beam current is about 100 mA. Focusability requires a normalized (edge) emittance ∼2 π-mm-mrad. Here, lithium aluminosilicate ion sources, of β-eucryptite, are being studied within the scope of NDCX-II construction. Several small (0.64 cm diameter) lithium aluminosilicate ion sources, on 70%-80% porous tungsten substrate, were operated in a pulsed mode. The distance between the source surface and the mid-plane of the extraction electrode (1 cm diameter aperture) was 1.48 cm. The source surface temperature was at 1220 C to 1300 C. A 5-6 (micro)s long beam pulsed was recorded by a Faraday cup (+300 V on the collector plate and -300 V on the suppressor ring). Figure 1 shows measured beam current density (J) vs. V 3/2 . A space-charge limited beam density of ∼1 mA/cm 2 was measured at 1275 C temperature, after allowing a conditioning time of about ∼ 12 hours. Maximum emission limited beam current density of (ge) 1.8mA/cm 2 was recorded at 1300 C with 10-kV extractions. Figure 2 shows the lifetime of two typical sources with space-charge limited beam current emission at a lower extraction voltage (1.75 kV) and at temperature of 1265 ± 7 C. These data demonstrate a constant, space-charge limited beam current for 20-50 hours. The lifetime of a source is determined by the loss of lithium from the alumino-silicate material either as ions or as neutral

  19. Confrontation of the Magnetically Arrested Disc Scenario with Observations of FR II Sources

    Energy Technology Data Exchange (ETDEWEB)

    Rusinek, Katarzyna; Sikora, Marek, E-mail: krusinek@camk.edu.pl [Nicolaus Copernicus Astronomical Center, Polish Academy of Sciences, Warsaw (Poland)

    2017-10-12

    The main aim of our work was to check whether powers of jets in FR II radio galaxies (RGs) and quasars (QSOs) can be reproduced by the Magnetically Arrested Disc (MAD) scenario. Assuming that established in the recent numerical simulations of the MAD scenario the (H/R){sup 2} dependence of the jet production efficiency is correct, we demonstrate that in order to reproduce the observed jet powers in FR II sources: (i) accretion discs must be geometrically much thicker than the standard ones; (ii) and/or that the jet production is strongly modulated.

  20. Hydrocyanation of sulfonylimines using potassium hexacyanoferrate(II) as an eco-friendly cyanide source

    International Nuclear Information System (INIS)

    Li, Zheng; Li, Rongzhi; Zheng, Huanhuan; Wen, Fei; Li, Hongbo; Yin, Junjun; Yang, Jingya

    2013-01-01

    An efficient and eco-friendly method for hydrocyanation of sulfonylimines via one-pot two-step procedure using potassium hexacyanoferrate)II) as cyanide source, benzoyl chloride as a promoter, and potassium carbonate as a base is described. This protocol has the features of using nontoxic, nonvolatile and inexpensive cyanide source, high yield, and simple work-up procedure. (author)

  1. Hydrocyanation of sulfonylimines using potassium hexacyanoferrate(II) as an eco-friendly cyanide source

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zheng; Li, Rongzhi; Zheng, Huanhuan; Wen, Fei; Li, Hongbo; Yin, Junjun; Yang, Jingya, E-mail: lizheng@nwnu.edu.cn [Key Laboratory of Eco-Environment-Related Polymer Materials for Ministry of Education, College of Chemistry and Chemical Engineering, Northwest Normal University, Gansu (China)

    2013-11-15

    An efficient and eco-friendly method for hydrocyanation of sulfonylimines via one-pot two-step procedure using potassium hexacyanoferrate)II) as cyanide source, benzoyl chloride as a promoter, and potassium carbonate as a base is described. This protocol has the features of using nontoxic, nonvolatile and inexpensive cyanide source, high yield, and simple work-up procedure. (author)

  2. FRM-II research neutron source commissioned; Eroeffnung der Forschungs-Neutronenquelle Heinz Maier-Leibnitz - FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2004-07-01

    On March 2, 2004, the Heinz Maier-Leibnitz research neutron source (FRM-II) generated neutrons for the first time. This marked the most important step on the way to using FRM-II for scientific purposes. On this occasion, this unique research facility in the world was dedicated in a ceremony attended by approximately 1000 representatives of politics, industry, and science. The keynote speaker, Federal Minister of the Interior Otto Schily; Bavarian Minister President Edmund Stoiber; Professor Claus Weyrich (Member of the Executive Board of Siemens AG); Dr. Thomas Goppel (Bavarian State Minister for Science, Research, and Arts); Professor Wolfgang A. Herman (President of the Technical University of Munich); Hannelore Gabor (2nd Mayor of the host municipality of Garching); and Professor Winfried Petry (Scientific Director of FRM-II) underlined the great importance of FRM-II for science, research, medicine, and technology. FRM-II will not only fill the 'neutron gap', but create extremely brilliant working conditions thanks to its considerably higher neutron flux compared to that of its predecessor, the legendary Atomic Egg. After the first conceptual design studies starting in 1980, the ground breaking ceremony in August 1996, and the third partial permit issued at Easter of 2003, a unique tool is now available for modern science and for medical and technical applications. (orig.) [German] Am 2. Maerz 2004 hat die Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM-II) erstmals Neutronen erzeugt. Damit war der wichtigste Schritt erreicht, der den Weg zur wissenschaftlichen Nutzung des FRM-II einleitet. Aus diesem Anlass wurde unter Teilnahme von rund 1 000 Vertretern aus Politik, Wirtschaft und Wissenschaft diese weltweit einmalige Forschungseinrichtung eroeffnet und ihrer Bestimmung uebergeben. Die Festredner, Bundesinnenminister Otto Schily, der bayerische Ministerpraesident Edmund Stoiber, Professor Claus Weyrich (Mitglied des Vorstands der Siemens AG), Dr

  3. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL

    2008-12-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.

  4. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    International Nuclear Information System (INIS)

    Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.

    2008-01-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies

  5. Getting to the Source: a Survey of Quantitative Data Sources Available to the Everyday Librarian: Part II: Data Sources from Specific Library Applications

    Directory of Open Access Journals (Sweden)

    Lisa Goddard

    2007-03-01

    Full Text Available This is the second part of a two-part article that provides a survey of data sources which are likely to be immediately available to the typical practitioner who wishes to engage in statistical analysis of collections and services within his or her own library. Part I outlines the data elements which can be extracted from web server logs, and discusses web log analysis tools. Part II looks at logs, reports, and data sources from proxy servers, resource vendors, link resolvers, federated search engines, institutional repositories, electronic reference services, and the integrated library system.

  6. LEVIS active anode lithium ion source development on PBFA-II

    International Nuclear Information System (INIS)

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Clark, B.F.; Reyes, C.; Bailey, J.E.; Filuk, A.B.; Desjarlais, M.P.; Johnson, D.J.; Carlson, A.L.; Lake, P.

    1993-01-01

    Experiments are ongoing on the PBFA-II Accelerator (10 MV typical, 50 ns) to optimize an active lithium ion source in a 15-cm focusing Applied-B ion diode using the LEVIS (Laser Evaporation Ion Source) process. Two laser pulses impinge on a thin (500 nm) Li or Li-bearing alloy on an insulating substrate. A Nd:YAG laser beam (1 μm, 8 ns, 0.1--0.2 J/cm 2 ) creates a thin (∼1 mm) Li vapor, which is then ionized by a 30--60 mJ/cm 2 dye laser tuned to the first resonant transition of Li (670.8 nm). In order to achieve a high-purity Li beam on PBFA-II with LEVIS, it has proven necessary to clean the anode surface in some way. The principal technique has been DC-heating of the anode to temperatures of 150--200 C for typically 5 hours, and for as long as 13 hours, prior to machine firing. Use of a LiAg alloy and YAG energy densities of 200 mJ/cm 2 have yielded beams of Li purity greater than 90%. They authors also plan to test a diode configuration that deposits Li in-situ on the anode surface just prior to the machine shot, as an alternative to DC-heating

  7. Sources of long-lived atmospheric VOCs at the rural boreal forest site, SMEAR II

    Science.gov (United States)

    Patokoski, J.; Ruuskanen, T. M.; Kajos, M. K.; Taipale, R.; Rantala, P.; Aalto, J.; Ryyppö, T.; Nieminen, T.; Hakola, H.; Rinne, J.

    2015-12-01

    In this study a long-term volatile organic compound (VOCs) concentration data set, measured at the SMEAR II (Station for Measuring Ecosystem-Atmosphere Relations) boreal forest site in Hyytiälä, Finland during the years 2006-2011, was analyzed in order to identify source areas and profiles of the observed VOCs. VOC mixing ratios were measured using proton transfer reaction mass spectrometry. Four-day HYSPLIT 4 (Hybrid Single Particle Lagrangian Integrated Trajectory) backward trajectories and the Unmix 6.0 receptor model were used for source area and source composition analysis. Two major forest fire events in Russia took place during the measurement period. The effect of these fires was clearly visible in the trajectory analysis, lending confidence to the method employed with this data set. Elevated volume mixing ratios (VMRs) of non-biogenic VOCs related to forest fires, e.g. acetonitrile and aromatic VOCs, were observed. Ten major source areas for long-lived VOCs (methanol, acetonitrile, acetaldehyde, acetone, benzene, and toluene) observed at the SMEAR II site were identified. The main source areas for all the targeted VOCs were western Russia, northern Poland, Kaliningrad, and the Baltic countries. Industrial areas in northern continental Europe were also found to be source areas for certain VOCs. Both trajectory and receptor analysis showed that air masses from northern Fennoscandia were less polluted with respect to both the VOCs studied and other trace gases (CO, SO2 and NOx), compared to areas of eastern and western continental Europe, western Russia, and southern Fennoscandia.

  8. High Fidelity Down-Conversion Source for Secure Communications using On-Demand Single Photons, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this NASA SBIR Phase II effort, AdvR will design and build an efficient, fully integrated, waveguide based, source of spectrally uncorrelated photon pairs that...

  9. THE Low-level Radio Frequency System for the superconducting cavities of National Synchrotron Light Source II

    International Nuclear Information System (INIS)

    Ma, H.; Rose, J.; Holub, B.; Cupolo, J.; Oliva, J.; Sikora, R.; Yeddulla, M.

    2011-01-01

    A digital low-level radio frequency (LLRF) field controller has been developed for the storage ring of The National Synchrotron Light Source-II (NSLS-II). The primary performance goal for the LLRF is to support the required RF operation of the superconducting cavities with a beam current of 500mA and a 0.14 degree or better RF phase stability. The digital field controller is FPGA-based, in a standard format 19-inch/I-U chassis. It has an option of high-level control support with MATLAB running on a local host computer through a USB2.0 port. The field controller has been field tested with the high-power superconducting RF (SRF) at Canadian light Source, and successfully stored a high beam current of 250 mA. The test results show that required specifications for the cavity RF field stability are met. This digital field controller is also currently being used as a development platform for other functional modules in the NSLS-II RF systems.

  10. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  11. Background sources and masks for Mark II detector at PEP

    International Nuclear Information System (INIS)

    Kadyk, J.

    1981-06-01

    The shielding masks currently at use in several of the current experiments at PEP are the result of an early organized effort to understand the sources of particle background expected at PEP, followed by the evolution of the conceptual designs into actual hardware. The degree and kind of background particle loading which could be tolerated was expected to differ significantly among the different experiments, and several designs emerged from the common study. Qualitatively, the types of radiations studied were, Synchrotron Radiation (SR), Beam Gas Bremsstrahlung (BGB), and, to a limited extent others, e.g., Electroproduction (EP). Calculations will be given of predicted occupancies in the pipe counter and other sensitive elements at small radius, since these will be most susceptible to the SR and BGB backgrounds. The calculations presented in this note are specific to the Mark II detector. Some general statements will be made first about the character of each of the various types of backgrounds considered, then some detailed calculations made for application to the Mark II detector

  12. RTNS-II: experience at 14-MeV source strengths between 1 x 1013 and 4 x 1013 n/s

    International Nuclear Information System (INIS)

    Davis, J.C.

    1986-05-01

    The design concepts, operational experience, and modifications of the two RTNS-II (Rotating Target Neutron Source-II) 14 MeV neutron sources are reviewed. The original design called for operation at a peak neutron source strength of 4 x 10 13 n/cm 2 s. The facility was to operate at high plant factor and at an acceptable cost in both dose delivered to operating staff and releases to the environment. The possibilities of higher source strengths are discussed in light of the operating experience to date and of new technologies that may be applied to the problems of high flux generators of this type. Changes in ancillary equipment that would provide more efficient or safe operation are also indicated

  13. Mini-D{sub 2} a source for ultracold neutrons at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Altarev, I.; Hartmann, F.J.; Paul, S.; Schott, W.; Trinks, U.; Gobrecht, K.; Gutsmiedl, E. [Technische Universitaet Muenchen, Garching (Germany); Scheuer, A. [TUEV Rheinland, Koeln (Germany)

    2001-03-01

    The new Munich high-flux reactor FRM-II offers the possibility to install a unique source for ultracold neutrons (UCN), the Mini-D{sub 2} UCN source, with a small volume of solid deuterium at a temperature of 5 K as converter, exposed to the cold neutron flux. This new source, being dedicated for storage experiments, is designed to be much superior to any existing UCN facility. In the pulsed operation mode the Mini-D{sub 2} source is expected to provide UCN densities up to 10{sup 4} n/cm{sup 3}. This density is orders of magnitude larger than that from the best existing source at Institut Laue Langevin (ILL) in Grenoble ({approx}50 n/cm{sup 3} at the exit of the neutron turbine). The large gain factor will enable new precision measurements of elementary properties of the free neutron, especially the electric dipole moment, the lifetime, and the angular correlation coefficients of the decay. These quantities are of fundamental interest in particle physics. Operated in the continuous mode, the UCN source will provide an UCN flux density of up to 5{center_dot}10{sup 5} n/cm{sup 2}s at the exit, to be compared with {approx}3{center_dot}10{sup 4} n/cm{sup 2}s at ILL. This improved UCN-flux offers new possibilities for traditional studies with UCN. (author)

  14. Expansion design for a radioactive sources handling laboratory type II class B

    International Nuclear Information System (INIS)

    Sanchez S, P. S.; Monroy G, F.; Alanis, J.

    2013-10-01

    The Radioactive Wastes Research Laboratory (RWRL) of the Instituto Nacional de Investigaciones Nucleares (Mexico), at the moment has three sections: instrumental analysis, radioactive material processes, counting and a license type II class C, to manipulate radioactive material. This license limits the open sources handling to 300 kBq for radionuclides of very high radio-toxicity as the Ra-226, for what is being projected the license extension to type II class B, to be able to manage until 370 MBq of this radionuclides type, and the Laboratory, since the location where is the RWRL have unused area. This work presents a proposal of the RWRL expansion, taking into account the current laboratory sections, as well as the established specifications by the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The current planes of the RWRL and the expansion proposal of the laboratory are presented. (Author)

  15. Latest experience on insertion devices at the National Synchrotron Light Source-II

    International Nuclear Information System (INIS)

    Tanabe, Toshiya; Cappadoro, Peter; Corwin, Todd

    2016-01-01

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy with the horizontal emittance of the electron beam being 0.9 nm.rad. Nine In-Vacuum Undulators (IVUs) are utilized at the NSLS-II as of February 2016. All IVUs have a unique side window derived from the experience from the CHESS facility in Cornell University. An R and D activity called 'Vacuum Seal Test' was conducted to ensure the viability of aluminum wire seal. Another R and D activity to develop a measurement system for Cryogenic Permanent Magnet Undulator (CPMU) was also performed. Other in-air devices, namely damping wigglers (DWs) and elliptically polarizing undulators (EPUs) utilize extruded aluminum chambers with Non-Evaporable Getter (NEG) coating. The beam-based integral estimates were obtained from the virtual kicks at the upstream and downstream of the undulator that best fit the measured orbit distortion in a model lattice with Tracy. In some cases, there are fairly large discrepancies between magnetic measurement data and observed integrals by the beam. Beam studies were carried out to explain the discrepancies mentioned earlier. The latest experiences on ID development and commissioning are discussed in conjunction with related activities in the world. (author)

  16. The new German neutron source FRM-II

    International Nuclear Information System (INIS)

    Nuding, M.

    2003-01-01

    The 'Technische Universitaet Muenchen' has built a new high-flux research reactor, the 'Forschungsreaktor Muenchen'-II. This new reactor will replace the 'Forschungsreaktor Muenchen' which has been operated very successfully for about 43 years. The 'Forschungsreaktor Muenchen'-II has been developed with first priority for beam-tube experiments, but it will also provide possibilities for irradiation experiments or isotope production. The reactor was designed to obtain a high and spectrally pure thermal neutron flux is available in a large volume outside of the core, where it is accessible for experimental use. In addition to beam-tubes which will end in the thermal neutron field there will be beam-tubes that will provide - with the help of 'spectrum shifters' -cold; hot and fast neutrons. Even through the thermal power of the 'Forschungsreaktor Muenchen'-II was limited to 20 MW an unperturbed maximum thermal neutron flux of about 8 x 10 14 cm -2 s -1 will be reached. Because of its 'compact-core-concept' the 'Forschungsreaktor Muenchen'-II will have the best flux-to-power-ratio worldwide: The fuel element and its highly enriched U 3 Si 2 -Al-fuel were tested during the licensing procedure of the 'Forschungsreaktor Muenchen'-II. Within the scope of this 'hydraulic test' the stability and the vibration behavior of the fuel plates as well as the long-tem behavior of the fuel element were investigated (Authors)

  17. dena grid study II. Integration of renewable energy sources into the German power supply system until 2020; dena - Netzstudie II. Integration erneuerbarer Energien in die deutsche Stromversorgung bis 2020

    Energy Technology Data Exchange (ETDEWEB)

    Agricola, Annegret C.; Seidl, Hannes; Zoch, Immo (comps.)

    2010-12-15

    With its broad system approach, dena Grid Study II describes new ways of developing Germany's integrated grid with regard to the expansion of renewable energy sources and taking not only an economically optimised conventional power generation system but also European power trading into account. Basis for detailed grid planning. Having investigated many different transmission technologies, grid management measures and options for increasing flexibility on both the supply and demand side, the study does much more than simply identify grid expansion requirements, it shows the path towards overall optimisation of the energy supply system. In addition to robustly identifying grid expansion requirements, dena Grid Study II provides a very sound basis for further detailed grid planning and the identification of specific power routes in the German power transmission grid. Increasing grid expansion requirements. dena Grid Study II investigates the expansion of electricity generation from renewable energy sources to 39 percent by 2020. However, this is just an interim goal. By as soon as 2030, the German Federal Government is planning to raise the proportion of renewable electricity generation to 50 percent. This shows that even after 2020, further adaptation of grid infrastructure will still be necessary. Practical action required. If the grid expansion required to integrate renewable energy sources is to be achieved rapidly, there is an urgent need to back up the grid expansion scenarios presented in dena Grid Study II with practical action. (orig.)

  18. Tank waste source term inventory validation. Volume II. Letter report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories.

  19. Tank waste source term inventory validation. Volume II. Letter report

    International Nuclear Information System (INIS)

    1995-04-01

    This document comprises Volume II of the Letter Report entitled Tank Waste Source Term Inventory Validation. This volume contains Appendix C, Radionuclide Tables, and Appendix D, Chemical Analyte Tables. The sample data for selection of 11 radionuclides and 24 chemical analytes were extracted from six separate sample data sets, were arranged in a tabular format and were plotted on scatter plots for all of the 149 single-shell tanks, the 24 double-shell tanks and the four aging waste tanks. The solid and liquid sample data was placed in separate tables and plots. The sample data and plots were compiled from the following data sets: characterization raw sample data, recent core samples, D. Braun data base, Wastren (Van Vleet) data base, TRAC and HTCE inventories

  20. Immobilized Tannin from Sanseviera trifasciata on Carbon as Adsorbent For Iron(II in Polluted Water Source

    Directory of Open Access Journals (Sweden)

    Irfan Hanafi Arif

    2016-03-01

    Full Text Available The organic-agricultural waste resulted from local farmer or community gardening recently paid public attention. The presence and easily grown of “Lidah Mertua” or Sanseviera trifasciata being focused on potency investigation for its prospecting application. It was reported contain some phenolic and also tannin extracted from aqueous solvents. This paper revealed recent investigation applying of its isolated tannin from leave part to modifying of activated carbon. The previous report published that carbon were able to adsorb some toxic heavy metals. However, it has some limitation including lower capacity adsorption. Impregnated or immobilized the tannin-isolated from S. trifasciata leaves was able to modify the carbon functionality, physical appearance, pores size, and it adsorption capacity. Both Langmuir and Freundlich adsorption mechanism model also disclosed the developed adsorbent mechanism of iron(II adsorption on the adsorbent tannin-immobolized on carbon. The real test using community well drilling water source also gave important finding on the concentration of iron(II contained on water source.

  1. RTNS-II operations guidebook

    International Nuclear Information System (INIS)

    Heikkinen, D.W.

    1985-01-01

    This guidebook is intended to provide training criteria, procedures and guidelines for operation of the RTNS-II neutron sources and ancilliary equipment. Use of this document requires full knowledge of the RTNS-II Facility Safety Procedure (FSP) and any Operational Safety Procedures (OSP) in effect. The RTNS-II FSP defines the hazards which may be encountered at RTNS-II and defines the procedures which must be followed in performing any task including operations. The purpose of this document is to provide a central source of detailed information concerning systems and equipment used in operating the RTNS-II neutron sources on a day-to-day basis. All members of the Operations Group are expected to be familiar with its contents. It is also intended to be used in training new members of the Operations Group

  2. The new German neutron source FRM-II

    International Nuclear Information System (INIS)

    Nuding, M.; Axmann, A.; Boening, K.

    2002-01-01

    The construction of a new high-flux research reactor, the FRM-II is finished. This new reactor shall replace the existing FRM, which has been operated very successfully for about 43 years. The report at first presents the main applications of the FRM-II and its core and plant design. After that a description of the tests performed during the licensing procedure is given. At the end some current topics are discussed and an outlook on the time schedule is presented [ru

  3. Nsls-II Boster

    Science.gov (United States)

    Gurov, S. M.; Akimov, A. V.; Akimov, V. E.; Anashin, V. V.; Anchugov, O. V.; Baranov, G. N.; Batrakov, A. M.; Belikov, O. V.; Bekhtenev, E. A.; Blum, E.; Bulatov, A. V.; Burenkov, D. B.; Cheblakov, P. B.; Chernyakin, A. D.; Cheskidov, V. G.; Churkin, I. N.; Davidsavier, M.; Derbenev, A. A.; Erokhin, A. I.; Fliller, R. P.; Fulkerson, M.; Gorchakov, K. M.; Ganetis, G.; Gao, F.; Gurov, D. S.; Hseuh, H.; Hu, Y.; Johanson, M.; Kadyrov, R. A.; Karnaev, S. E.; Karpov, G. V.; Kiselev, V. A.; Kobets, V. V.; Konstantinov, V. M.; Kolmogorov, V. V.; Korepanov, A. A.; Kramer, S.; Krasnov, A. A.; Kremnev, A. A.; Kuper, E. A.; Kuzminykh, V. S.; Levichev, E. B.; Li, Y.; Long, J. De; Makeev, A. V.; Mamkin, V. R.; Medvedko, A. S.; Meshkov, O. I.; Nefedov, N. B.; Neyfeld, V. V.; Okunev, I. N.; Ozaki, S.; Padrazo, D.; Petrov, V. V.; Petrichenkov, M. V.; Philipchenko, A. V.; Polyansky, A. V.; Pureskin, D. N.; Rakhimov, A. R.; Rose, J.; Ruvinskiy, S. I.; Rybitskaya, T. V.; Sazonov, N. V.; Schegolev, L. M.; Semenov, A. M.; Semenov, E. P.; Senkov, D. V.; Serdakov, L. E.; Serednyakov, S. S.; Shaftan, T. V.; Sharma, S.; Shichkov, D. S.; Shiyankov, S. V.; Shvedov, D. A.; Simonov, E. A.; Singh, O.; Sinyatkin, S. V.; Smaluk, V. V.; Sukhanov, A. V.; Tian, Y.; Tsukanova, L. A.; Vakhrushev, R. V.; Vobly, P. D.; Utkin, A. V.; Wang, G.; Wahl, W.; Willeke, F.; Yaminov, K. R.; Yong, H.; Zhuravlev, A.; Zuhoski, P.

    The National Synchrotron Light Source II is a third generation light source, which was constructed at Brookhaven National Laboratory. This project includes a highly-optimized 3 GeV electron storage ring, linac preinjector, and full-energy synchrotron injector. Budker Institute of Nuclear Physics built and delivered the booster for NSLS-II. The commissioning of the booster was successfully completed. This paper reviews fulfilled work by participants.

  4. NuSTAR, XMM-Newton and Suzaku Observations of the Ultraluminous X-Ray Source Holmberg II X-1

    DEFF Research Database (Denmark)

    Walton, D. J.; Middleton, M. J.; Rana, V.

    2015-01-01

    We present the first broadband 0.3-25.0 keV X-ray observations of the bright ultraluminous X-ray source (ULX) Holmberg II X-1, performed by NuSTAR, XMM-Newton, and Suzaku in 2013 September. The NuSTAR data provide the first observations of Holmberg II X-1 above 10 keV and reveal a very steep high...

  5. Top-up operation at Pohang Light Source-II

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, I.; Huang, J. Y.; Kim, M.; Lee, B.-J.; Kim, C.; Choi, J.-Y.; Kim, M.-H.; Lee, H. S.; Moon, D.; Lee, E. H.; Kim, D.-E.; Nam, S. H.; Shin, S. [Pohang Accelerator Laboratory, Pohang, Kyungbuk 790-834 (Korea, Republic of); Cho, Moohyun [Department of Physics, POSTECH, Pohang, Kyungbuk 790-834 (Korea, Republic of)

    2014-05-15

    After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si ) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan.

  6. FLICKERING OF 1.3 cm SOURCES IN SGR B2: TOWARD A SOLUTION TO THE ULTRACOMPACT H II REGION LIFETIME PROBLEM

    Energy Technology Data Exchange (ETDEWEB)

    De Pree, C. G.; Monsrud, A. [Agnes Scott College, 141 East College Avenue, Decatur, GA 30030 (United States); Peters, T. [Institut für Theoretische Physik, Universität Zürich, CH-8057 Zürich (Switzerland); Mac Low, M.-M. [American Museum of Natural History, New York, NY 10024 (United States); Wilner, D. J.; Keto, E. R. [Harvard-Smithsonian CfA, Cambridge, MA 02138 (United States); Goss, W. M. [National Radio Astronomy Observatory, Socorro, NM 87801 (United States); Galván-Madrid, R. [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching (Germany); Klessen, R. S. [Zentrum für Astronomie, Institut für Theoretische Astrophysik, Universität Heidelberg, Albert-Ueberle-Str. 2, D-69120 Heidelberg (Germany)

    2014-02-01

    Accretion flows onto massive stars must transfer mass so quickly that they are themselves gravitationally unstable, forming dense clumps and filaments. These density perturbations interact with young massive stars, emitting ionizing radiation, alternately exposing and confining their H II regions. As a result, the H II regions are predicted to flicker in flux density over periods of decades to centuries rather than increase monotonically in size as predicted by simple Spitzer solutions. We have recently observed the Sgr B2 region at 1.3 cm with the Very Large Array in its three hybrid configurations (DnC, CnB, and BnA) at a resolution of ∼0.''25. These observations were made to compare in detail with matched continuum observations from 1989. At 0.''25 resolution, Sgr B2 contains 41 ultracompact (UC) H II regions, 6 of which are hypercompact. The new observations of Sgr B2 allow comparison of relative peak flux densities for the H II regions in Sgr B2 over a 23 year time baseline (1989-2012) in one of the most source-rich massive star forming regions in the Milky Way. The new 1.3 cm continuum images indicate that four of the 41 UC H II regions exhibit significant changes in their peak flux density, with one source (K3) dropping in peak flux density, and the other three sources (F10.303, F1, and F3) increasing in peak flux density. The results are consistent with statistical predictions from simulations of high mass star formation, suggesting that they offer a solution to the lifetime problem for UC H II regions.

  7. Status of TRR-II cold neutron source

    International Nuclear Information System (INIS)

    Lee, C.H.; Guung, T.C.; Lan, K.C.; Chan, Y.K.; Wang, C.H.; Chen, S.K.

    2001-01-01

    The Taiwan research reactor improvement and the utilization promotion project (TRR-II) with a vertical cold neutron source (CNS) is carrying out at the Institute of Nuclear Energy Research (INER). The CNS with a two-phase thermosiphon loop consists of an annular cylindrical moderator cell, a single moderator transfer tube and a condenser. A cylindrical annulus moderator cell with boiling liquid hydrogen at 1.2 bar and 20.7 K gives an optimum moderation for cold neutrons in the wavelength range between 4 A and 15 A. The moderator cell lies around 400 mm away from the core center. Its perturbed thermal flux is about 1.4 x 10 14 cm -2 s -1 . It is close to the maximum thermal neutron flux area in D 2 O tank to get the maximum possible brightness about 1 x 10 12 n cm -2 s -1 A -1 sterad -1 at 4 A. An experimental study for thermal-hydraulic characteristics of the two-phase thermosiphon loop has been performed on a full-scale mockup loop using a Freon-11 as a working fluid. The objective of the mockup testing is to validate operation and heat removal capacity in CNS hydrogen loop design. Moreover, this loop will be used to demonstrate no onset of flooding and flow oscillations in a single transfer tube under CNS normal and abnormal conditions. The flooding limitation, the liquid level, and the void fraction in the moderator cell as a function of the initial Freon-11 inventory, the heat load, and the moderator cell geometry are also reported. (orig.)

  8. International cooperation at RTNS-II

    International Nuclear Information System (INIS)

    Logan, C.M.

    1984-02-01

    The Rotating Target Neutron Source-II (RTNS-II) facility at LLNL is a unique materials-test facility. It provides the most intense source of 14-MeV neutrons in the world. Dedicated operation in support of the fusion-materials-research community began in early 1979. Three years later, the Japanese Ministry of Education, Science, and Culture (Monbusho) and the US Department of Energy agreed to jointly support the RTNS-II operation and to share in the use of the facility

  9. Thermal flow in detectors of CNA-II with spontaneous fissions source of 238U

    International Nuclear Information System (INIS)

    Mascitti, J. A

    2012-01-01

    The thermal flux in the position of ex-core and in-core CNA-II Nuclear Power Plant (CNA-II) detectors is estimated considering neutron from the 238 U spontaneous fissions as the source, for the reactor cold state (isothermal state with both coolant and moderator at a temperature of 60 o C, a pressure of 35 ata and 15.46 ppm of natural Boron), and 24% inserted control rods (slightly sub-critical). Results are obtained for two different situations: with and without photo-neutrons due to the (γ,n) reaction in D 2 O. It is concluded that the thermal flux is under the detection limit of the boron trifluoride 104-SR or 282-IB detectors (≅10 -1 cm-2.s -1 ). These detectors are located in opposite positions in the inner concrete shielding, having the lowest detection limit among all ex-core detectors. A significant difference is verified in neutron fluxes between both cases, which suggest that photo-neutrons in large heavy water reactors such as CNA-II should not be ignored. The total neutron flux attenuation factor between the inner and outer region of the reactor pressure vessel was estimated to be 7.0 x 10 -7 . It should be mentioned that none of the results here presented has been affected by any correction factor. Each value has a percentage relative error representing the statistical uncertainty due to the probabilistic Monte Carlo method used to obtain it (author)

  10. Market Analysis and Consumer Impacts Source Document. Part II. Review of Motor Vehicle Market and Consumer Expenditures on Motor Vehicle Transportation

    Science.gov (United States)

    1980-12-01

    This source document on motor vehicle market analysis and consumer impacts consists of three parts. Part II consists of studies and review on: motor vehicle sales trends; motor vehicle fleet life and fleet composition; car buying patterns of the busi...

  11. Pius II. a utrakvismus

    OpenAIRE

    Šimek, Milan

    2009-01-01

    Milan Šimek Pius II. a utrakvismus Pius II. and utraquism Based on sources work - out, the thesis aims the description and analysis of the attitude alternation of Enea Sylvio Piccolomini - Pius II to the utraquism. The conclusions stress the postulate that Pius II. did not change that attitude, but just did not succed in quelling the utraquist movement. In the sense of political background that finally led to fatal dissention among both leaders, king Jiří of Poděbrady and pope Pius II.

  12. Site Characterization of the Source Physics Experiment Phase II Location Using Seismic Reflection Data

    Science.gov (United States)

    Sexton, E. A.; Snelson, C. M.; Chipman, V.; Emer, D. F.; White, R. L.; Emmitt, R.; Wright, A. A.; Drellack, S.; Huckins-Gang, H.; Mercadante, J.; Floyd, M.; McGowin, C.; Cothrun, C.; Bonal, N.

    2013-12-01

    An objective of the Source Physics Experiment (SPE) is to identify low-yield nuclear explosions from a regional distance. Low-yield nuclear explosions can often be difficult to discriminate among the clutter of natural and man-made explosive events (e.g., earthquakes and mine blasts). The SPE is broken into three phases. Phase I has provided the first of the physics-based data to test the empirical models that have been used to discriminate nuclear events. The Phase I series of tests were placed within a highly fractured granite body. The evolution of the project has led to development of Phase II, to be placed within the opposite end member of geology, an alluvium environment, thereby increasing the database of waveforms to build upon in the discrimination models. Both the granite and alluvium sites have hosted nearby nuclear tests, which provide comparisons for the chemical test data. Phase III of the SPE is yet to be determined. For Phase II of the experiment, characterization of the location is required to develop the geologic/geophysical models for the execution of the experiment. Criteria for the location are alluvium thickness of approximately 170 m and a water table below 170 m; minimal fracturing would be ideal. A P-wave mini-vibroseis survey was conducted at a potential site in alluvium to map out the subsurface geology. The seismic reflection profile consisted of 168 geophone stations, spaced 5 m apart. The mini-vibe was a 7,000-lb peak-force source, starting 57.5 m off the north end of the profile and ending 57.5 m past the southern-most geophone. The length of the profile was 835 m. The source points were placed every 5 m, equally spaced between geophones to reduce clipping. The vibroseis sweep was from 20 Hz down to 180 Hz over 8 seconds, and four sweeps were stacked at each shot location. The shot gathers show high signal-to-noise ratios with clear first arrivals across the entire spread and the suggestion of some shallow reflectors. The data were

  13. Indigenous instrumentation for mass spectrometry: Part II - development of plasma source mass spectrometers. PD-5-3

    International Nuclear Information System (INIS)

    Nataraju, V.

    2007-01-01

    The growing demands from analytical community, for a precise isotope ratio and ultra trace concentration measurements, has lead to significant improvement in mass spectrometer instrumentation development with respect to sensitivity, detection limits, precision and accuracy. Among the many analytical techniques available, plasma source mass spectrometers like Inductively Coupled Plasma Mass Spectrometry (ICPMS), multi collector (MC) ICPMS and Glow Discharge Mass Spectrometry (GDMS), have matured into reliable tools for the above applications. Where as ICPMS is by far the most successful method for aqueous solutions, GDMS is being applied for bulk and impurity analysis of conducting as well non-conducting solids. VPID, BARC has been developing mass spectrometers for different inorganic applications of DAE users. Over the years expertise has been developed in all the aspects of mass spectrometry instrumentation. Part 1 of this indigenous instrumentation on mass spectrometry gives details of magnetic sector instruments with either EI or TI source for isotopic ratio analysis. The present paper is a continuation of that on plasma source and quadrupole mass spectrometers. This paper covers i) ICP-QMS, ii) MC-ICPMS, iii) GDMS and iv) QMS

  14. One-pot four-component synthesis of 2-aryl-3,3-dihaloacrylonitriles using potassium hexacyanoferrate(II) as environmentally benign cyanide source

    International Nuclear Information System (INIS)

    Zhao, Zhouxing; Li, Zheng

    2011-01-01

    An efficient route to one-pot four-component reactions of aroyl chlorides, potassium hexacyanoferrate(II), triphenylphosphine and carbon tetrahalides to synthesize 2-aryl-3,3-dichloroacrylonitriles and 2-aryl-3,3-dibromoacrylonitriles was described. This protocol has advantages of use of non-toxic cyanide source, high yield and simple work-up procedure. (author)

  15. World War II Homefront.

    Science.gov (United States)

    Garcia, Rachel

    2002-01-01

    Presents an annotated bibliography that provides Web sites focusing on the U.S. homefront during World War II. Covers various topics such as the homefront, Japanese Americans, women during World War II, posters, and African Americans. Includes lesson plan sources and a list of additional resources. (CMK)

  16. Motion of the sources for type II and type IV radio bursts and flare-associated interplanetary disturbances

    Science.gov (United States)

    Sakurai, K.; Chao, J. K.

    1974-01-01

    Shock waves are indirectly observed as the source of type II radio bursts, whereas magnetic bottles are identified as the source of moving metric type IV radio bursts. The difference between the expansion speeds of these waves and bottles is examined during their generation and propagation near the flare regions. It is shown that, although generated in the explosive phase of flares, the bottles behave quite differently from the waves and that the bottles are generally much slower than the waves. It has been suggested that the waves are related to flare-associated interplanetary disturbances which produce SSC geomagnetic storms. These disturbances may, therefore, be identified as interplanetary shock waves. The relationship among magnetic bottles, shock waves near the sun, and flare-associated disturbances in interplanetary space is briefly discussed.

  17. Expansion design for a radioactive sources handling laboratory type II class B; Diseno de ampliacion para un laboratorio de manejo de fuentes radiactivas tipo II clase B

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez S, P. S. [Universidad Mexiquense del Bicentenario, Av. Industria Poniente s/n, Parque Industrial Dona Rosa, 52000 Lerma, Estado de Mexico (Mexico); Monroy G, F.; Alanis, J., E-mail: salvador-21@live.com.mx [ININ, Carretera Mexico-Touca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The Radioactive Wastes Research Laboratory (RWRL) of the Instituto Nacional de Investigaciones Nucleares (Mexico), at the moment has three sections: instrumental analysis, radioactive material processes, counting and a license type II class C, to manipulate radioactive material. This license limits the open sources handling to 300 kBq for radionuclides of very high radio-toxicity as the Ra-226, for what is being projected the license extension to type II class B, to be able to manage until 370 MBq of this radionuclides type, and the Laboratory, since the location where is the RWRL have unused area. This work presents a proposal of the RWRL expansion, taking into account the current laboratory sections, as well as the established specifications by the Comision Nacional de Seguridad Nuclear y Salvaguardias (CNSNS). The current planes of the RWRL and the expansion proposal of the laboratory are presented. (Author)

  18. CHANDRA OBSERVATIONS OF 3C RADIO SOURCES WITH z < 0.3. II. COMPLETING THE SNAPSHOT SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Massaro, F. [SLAC National Laboratory and Kavli Institute for Particle Astrophysics and Cosmology, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Tremblay, G. R. [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching bei Muenchen (Germany); Harris, D. E.; O' Dea, C. P. [Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, MA 02138 (United States); Kharb, P.; Axon, D. [Department of Physics, Rochester Institute of Technology, Carlson Center for Imaging Science 76-3144, 84 Lomb Memorial Dr., Rochester, NY 14623 (United States); Balmaverde, B.; Capetti, A. [INAF-Osservatorio Astrofisico di Torino, Strada Osservatorio 20, I-10025 Pino Torinese (Italy); Baum, S. A. [Carlson Center for Imaging Science 76-3144, 84 Lomb Memorial Dr., Rochester, NY 14623 (United States); Chiaberge, M.; Macchetto, F. D.; Sparks, W. [Space Telescope Science Institute, 3700 San Martine Drive, Baltimore, MD 21218 (United States); Gilli, R. [INAF-Osservatorio Astronomico di Bologna, Via Ranzani 1, I-40127 Bologna (Italy); Giovannini, G. [INAF-Istituto di Radioastronomia di Bologna, Via Gobetti 101, I-40129 Bologna (Italy); Grandi, P.; Torresi, E. [INAF-IASF-Istituto di Astrofisica Spaziale e fisica Cosmica di Bologna, Via P. Gobetti 101, I-40129 Bologna (Italy); Risaliti, G. [INAF-Osservatorio Astronomico di Arcetri, Largo E. Fermi 5, I-50125 Firenze (Italy)

    2012-12-15

    We report on the second round of Chandra observations of the 3C snapshot survey developed to observe the complete sample of 3C radio sources with z < 0.3 for 8 ks each. In the first paper, we illustrated the basic data reduction and analysis procedures performed for the 30 sources of the 3C sample observed during Chandra Cycle 9, while here we present the data for the remaining 27 sources observed during Cycle 12. We measured the X-ray intensity of the nuclei and of any radio hot spots and jet features with associated X-ray emission. X-ray fluxes in three energy bands, i.e., soft, medium, and hard, for all the sources analyzed are also reported. For the stronger nuclei, we also applied the standard spectral analysis, which provides the best-fit values of the X-ray spectral index and absorbing column density. In addition, a detailed analysis of bright X-ray nuclei that could be affected by pile-up has been performed. X-ray emission was detected for all the nuclei of the radio sources in our sample except for 3C 319. Among the current sample, there are two compact steep spectrum radio sources, two broad-line radio galaxies, and one wide angle tail radio galaxy, 3C 89, hosted in a cluster of galaxies clearly visible in our Chandra snapshot observation. In addition, we also detected soft X-ray emission arising from the galaxy cluster surrounding 3C 196.1. Finally, X-ray emission from hot spots has been found in three FR II radio sources and, in the case of 3C 459, we also report the detection of X-ray emission associated with the eastern radio lobe as well as X-ray emission cospatial with radio jets in 3C 29 and 3C 402.

  19. Irradiations at RTNS-II

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Logan, C.M.

    1982-01-01

    The RTNS-II 14-MeV neutron source facility at Lawrence Livermore National Laboratory is described. Average neutron source parameters are outlined. A brief general description of the irradiation program to the present time is given. A short discussion of guidelines for prospective users is also given

  20. A characterization and optimization study of Gamble II as an X-ray bremsstrahlung source

    International Nuclear Information System (INIS)

    Oliphant, W.F.; Boller, J.R.; Brown, D.G.; Cooperstein, G.; Dozier, C.M.; Stephanakis, S.J.

    1982-01-01

    The adverse effects of radiation on solid state devices are strongly spectrum dependent. It is thus essential that the radiation spectrum from flash x-ray sources be available when they are used as facilities for testing electronic components. This paper describes a preliminary study in which previously developed computer codes were used to calculate the radiation spectrum produced by NRL's Gamble II pulsed power generator. To determine how well the calculated spectrum matched the experimental one, doses in CaF 2 -Mn TLD's were computed for the dosimeters placed behind various thicknesses of Cu and Pb filters and compared with the experimentally measured doses. Using a diode model that was consistent with presently understood electron beam behavior, a spectrum was generated which predicted TLD doses to within about 15% of the experimentally measured values

  1. The Status of Kasimov Chinggisids during the Reigns of Vasily II and Ivan III according to Written Sources

    OpenAIRE

    M.A. Nesin

    2017-01-01

    Research objective: To study the issue both of the status of Kasimov Chinggisids as well as of the attitude toward the service Tatars and the Tatars who were allied to Moscow during the reigns of the great Moscow princes Vasily II and Ivan III. Research materials: Published and unpublished sources: books of official orders in the Russian state, chronicles, acts, diplomatic documents, etc. Results and novelty of the research: This work is the first comprehensive study of this topic. The ...

  2. RTNS-II 1984 annual report

    International Nuclear Information System (INIS)

    1984-01-01

    RTNS-II was built to provide a deuterium-tritium neutron source for the study of fusion neutron effects. In the quest to apply fusion to commercial power production, the specific mission of RTNS-II is threefold: to acquire direct engineering data for near-term confinement experiments and for materials that will see moderate neutron dose in future reactor systems; to measure production rates of transmutants and to develop appropriate radiation-resistant instrumentation for fusion systems; and to study the radiation-induced property changes caused by fusion neutrons. RTNS-II comprises two independent sources of 14-MeV neutrons. This is the third annual report summarizing irradiation experiments at RTNS-II. It covers calendar year 1983, and includes reports of all irradiation results, both fusion and non-fusion related. These comprise both secondary (or ''add-on'') and primary irradiations. Each summary article has been submitted by the investigator and has been altered only to meet the style and format requirements of this report

  3. Shielding NSLS-II light source: Importance of geometry for calculating radiation levels from beam losses

    Science.gov (United States)

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.; Wahl, W.

    2016-11-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produces significantly higher neutron component dose to the experimental floor than a lower energy beam injection and ramped operations. Minimizing this dose will require adequate knowledge of where the miss-steered beam can occur and sufficient EM shielding close to the loss point, in order to attenuate the energy of the particles in the EM shower below the neutron production threshold (weaknesses in the design before a high radiation incident occurs. The effort required to adequately define the accelerator geometry for these codes has been greatly reduced with the implementation of the graphical interface of FLAIR to FLUKA. This made the effective shielding process for NSLS-II quite accurate and reliable. The principles used to provide supplemental shielding to the NSLS-II accelerators and the lessons learned from this process are presented.

  4. LCLS-II high power RF system overview and progress

    Energy Technology Data Exchange (ETDEWEB)

    Yeremian, Anahid Dian

    2015-10-07

    A second X-ray free electron laser facility, LCLS-II, will be constructed at SLAC. LCLS-II is based on a 1.3 GHz, 4 GeV, continuous-wave (CW) superconducting linear accelerator, to be installed in the first kilometer of the SLAC tunnel. Multiple types of high power RF (HPRF) sources will be used to power different systems on LCLS-II. The main 1.3 GHz linac will be powered by 280 1.3 GHz, 3.8 kW solid state amplifier (SSA) sources. The normal conducting buncher in the injector will use four more SSAs identical to the linac SSAs but run at 2 kW. Two 185.7 MHz, 60 kW sources will power the photocathode dual-feed RF gun. A third harmonic linac section, included for linearizing the bunch energy spread before the first bunch compressor, will require sixteen 3.9 GHz sources at about 1 kW CW. A description and an update on all the HPRF sources of LCLS-II and their implementation is the subject of this paper.

  5. Loss distribution approach for operational risk capital modelling under Basel II: Combining different data sources for risk estimation

    Directory of Open Access Journals (Sweden)

    Pavel V. Shevchenko

    2013-07-01

    Full Text Available The management of operational risk in the banking industry has undergone significant changes over the last decade due to substantial changes in operational risk environment. Globalization, deregulation, the use of complex financial products and changes in information technology have resulted in exposure to new risks very different from market and credit risks. In response, Basel Committee for banking Supervision has developed a regulatory framework, referred to as Basel II, that introduced operational risk category and corresponding capital requirements. Over the past five years, major banks in most parts of the world have received accreditation under the Basel II Advanced Measurement Approach (AMA by adopting the loss distribution approach (LDA despite there being a number of unresolved methodological challenges in its implementation. Different approaches and methods are still under hot debate. In this paper, we review methods proposed in the literature for combining different data sources (internal data, external data and scenario analysis which is one of the regulatory requirement for AMA.

  6. Wormhole solutions sourced by fluids, II: three-fluid two-charged sources

    Energy Technology Data Exchange (ETDEWEB)

    Azreg-Ainou, Mustapha [Baskent University, Faculty of Engineering, Ankara (Turkey)

    2016-01-15

    Lack of a consistent metric for generating rotating wormholes motivates us to present a new one endowed with interesting physical and geometrical properties. When combined with the generalized method of superposition of fields, which consists in attaching a form of matter to each moving frame, it generates massive and charged (charge without charge) two-fluid-sourced, massive and two-charged three-fluid-sourced, rotating as well as new static wormholes which, otherwise, can hardly be derived by integration. If the lapse function of the static wormhole is bounded from above, no closed timelike curves occur in the rotating counterpart. For positive energy densities dying out faster than 1/r, the angular velocity includes in its expansion a correction term, to the leading one that corresponds to ordinary stars, proportional to ln r/r{sup 4}. Such a term is not present in the corresponding expansion for the Kerr-Newman black hole. Based on this observation and our previous work, the dragging effects of falling neutral objects may constitute a substitute for other known techniques used for testing the nature of the rotating black hole candidates that are harbored in the center of galaxies. We discuss the possibility of generating (n + 1)-fluid-sourced, n-charged, rotating as well as static wormholes. (orig.)

  7. Wormhole solutions sourced by fluids, II: three-fluid two-charged sources

    Energy Technology Data Exchange (ETDEWEB)

    Azreg-Aïnou, Mustapha, E-mail: azreg@baskent.edu.tr [Faculty of Engineering, Başkent University, Bağlıca Campus, 06810, Ankara (Turkey)

    2016-01-05

    Lack of a consistent metric for generating rotating wormholes motivates us to present a new one endowed with interesting physical and geometrical properties. When combined with the generalized method of superposition of fields, which consists in attaching a form of matter to each moving frame, it generates massive and charged (charge without charge) two-fluid-sourced, massive and two-charged three-fluid-sourced, rotating as well as new static wormholes which, otherwise, can hardly be derived by integration. If the lapse function of the static wormhole is bounded from above, no closed timelike curves occur in the rotating counterpart. For positive energy densities dying out faster than 1 / r, the angular velocity includes in its expansion a correction term, to the leading one that corresponds to ordinary stars, proportional to lnr/r{sup 4}. Such a term is not present in the corresponding expansion for the Kerr–Newman black hole. Based on this observation and our previous work, the dragging effects of falling neutral objects may constitute a substitute for other known techniques used for testing the nature of the rotating black hole candidates that are harbored in the center of galaxies. We discuss the possibility of generating (n+1)-fluid-sourced, n-charged, rotating as well as static wormholes.

  8. Recent progress at RTNS-II

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Logan, C.M.

    1984-01-01

    The Rotating Target Neutron Source (RTNS-II) facility produces 14-MeV neutrons for materials damage studies. Initial operation for irradiations, which occurred in 1979, began with a neutron source strength of 10 13 n/s utilizing one of the accelerator-based neutron sources. Details are given on improvements which have resulted in both increased neutron production and neutron source strength and improved control and monitoring. 8 references

  9. Probing HeII Reionization at z>3.5 with Resolved HeII Lyman Alpha Forest Spectra

    Science.gov (United States)

    Worseck, Gabor

    2017-08-01

    The advent of GALEX and COS have revolutionized our view of HeII reionization, the final major phase transition of the intergalactic medium. COS spectra of the HeII Lyman alpha forest have confirmed with high confidence the high HeII transmission that signifies the completion of HeII reionization at z 2.7. However, the handful of z>3.5 quasars observed to date show a set of HeII transmission 'spikes' and larger regions with non-zero transmission that suggest HeII reionization was well underway by z=4. This is in striking conflict with predictions from state-of-the-art radiative transfer simulations of a HeII reionization driven by bright quasars. Explaining these measurements may require either faint quasars or more exotic sources of hard photons at z>4, with concomitant implications for HI reionization. However, many of the observed spikes are unresolved in G140L spectra and are significantly impacted by Poisson noise. Current data cannot reliably probe the ionization state of helium at z>3.5.We request 41 orbits to obtain science-grade G130M spectra of the two UV-brightest HeII-transmitting QSOs at z>3.5 to confirm and resolve their HeII transmission spikes as an unequivocal test of early HeII reionization. These spectra are complemented by recently obtained data from 8m telescopes: (1) Echelle spectra of the coeval HI Lya forest to map the underlying density field that modulates the HeII absorption, and (2) Our dedicated survey for foreground QSOs that may source the HeII transmission. Our recent HST programs revealed the only two viable targets to resolve the z>3.5 HeII Lyman alpha forest, and to conclusively solve this riddle.

  10. Infrared study of seven possible compact H II regions

    International Nuclear Information System (INIS)

    Sibille, F.; Lunel, M.; Bergeat, J.

    1976-01-01

    We report observations of seven possible compact H II regions in the infrared with the hydrogen spectrum in order to derive extinction and emission measures. The emission measure is compared with available radio data. For two sources, agreement is found between radio and infrared data. Infrared excess is found in four sources, its origin is discussed. Two sources cannot be interpreted as compact H II regions. (orig.) [de

  11. Open Source Software: critical review of scientific literature and other sources

    OpenAIRE

    Querol del Amo, Marc

    2007-01-01

    This thesis presents the results of a survey of Open Source Licensing literature. It aims to assist the reader in choosing the best license for his/her business. For this reason, the content of this thesis can be divided into: (i) an open source licensing overview, (ii) the explication of the main features of the most popular open source licenses, (iii) the consequences of using one or another and (iv) the critical or controversial issues related to Open Source Licensing. Furthermore, at the ...

  12. NSLS-II commissioning and operation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, G., E-mail: gwang@bnl.gov; Shaftan, T.; Bassi, G.; Bengtsson, J.; Blednykh, A.; Blum, E.; Cheng, W.; Choi, J.; Davidsaver, M.; Doom, L.; Fliller, R.; Ganetis, G.; Guo, W.; Hidaka, Y.; Kramer, S.; Li, Y.; Podobedov, B.; Qian, K.; Rose, J.; Seletskiy, S. [Brookhaven National Laboratory, Upton, NY 11973 (United States); and others

    2016-07-27

    The National Synchrotron Light Source II at Brookhaven National Lab is a third-generation synchrotron radiation facility that has been commissioned in 2014. The facility is based on a 3 GeV electron storage ring, which will circulate 500 mA of beam current at 1 nm rad horizontal emittance. The storage ring is 792 meters in circumference and will accommodate more than 60 beamlines in the final built-out. The beamline sources range from insertion-devices located in straight sections, bending magnets or three-pole-wigglers configured in multiple branches. The NSLS-II storage ring commissioning was successfully completed in July 2014 and the facility delivered the first user light on October 23, 2014. Currently the storage ring reached 300 mA beam current and achieved 1 nm rad of horizontal emittance with 3 sets of Damping Wigglers. At this point six NSLS-II project beamlines are routinely taking photons with beam current at 150 mA. This paper reviews the NSLS-II accelerator design and commissioning experience.

  13. The SRP-II as a Rich Source of Data on the Psychopathic Personality

    Science.gov (United States)

    Lester, Whitney S.; Salekin, Randall T.; Sellbom, Martin

    2013-01-01

    This study examined the factor structure, external correlates, and predictive utility of the Self-Report Psychopathy scale (SRP-II; Hare, Harpur, & Hemphill, 1989). Despite a revision of the SRP-II to address, among other criticisms, a lack of items reflecting antisocial behavior, we hypothesized that the SRP-II would have a conceptually coherent…

  14. Anoxic and Oxic Oxidation of Rocks Containing Fe(II)Mg-Silicates and Fe(II)-Monosulfides as Source of Fe(III)-Minerals and Hydrogen. Geobiotropy.

    Science.gov (United States)

    Bassez, Marie-Paule

    2017-12-01

    In this article, anoxic and oxic hydrolyses of rocks containing Fe (II) Mg-silicates and Fe (II)-monosulfides are analyzed at 25 °C and 250-350 °C. A table of the products is drawn. It is shown that magnetite and hydrogen can be produced during low-temperature (25 °C) anoxic hydrolysis/oxidation of ferrous silicates and during high-temperature (250 °C) anoxic hydrolysis/oxidation of ferrous monosulfides. The high-T (350 °C) anoxic hydrolysis of ferrous silicates leads mainly to ferric oxides/hydroxides such as the hydroxide ferric trihydroxide, the oxide hydroxide goethite/lepidocrocite and the oxide hematite, and to Fe(III)-phyllosilicates. Magnetite is not a primary product. While the low-T (25 °C) anoxic hydrolysis of ferrous monosulfides leads to pyrite. Thermodynamic functions are calculated for elementary reactions of hydrolysis and carbonation of olivine and pyroxene and E-pH diagrams are analyzed. It is shown that the hydrolysis of the iron endmember is endothermic and can proceed within the exothermic hydrolysis of the magnesium endmember and also within the exothermic reactions of carbonations. The distinction between three products of the iron hydrolysis, magnetite, goethite and hematite is determined with E-pH diagrams. The hydrolysis/oxidation of the sulfides mackinawite/troilite/pyrrhotite is highly endothermic but can proceed within the heat produced by the exothermic hydrolyses and carbonations of ferromagnesian silicates and also by other sources such as magma, hydrothermal sources, impacts. These theoretical results are confirmed by the products observed in several related laboratory experiments. The case of radiolyzed water is studied. It is shown that magnetite and ferric oxides/hydroxides such as ferric trihydroxide, goethite/lepidocrocite and hematite are formed in oxic hydrolysis of ferromagnesian silicates at 25 °C and 350 °C. Oxic oxidation of ferrous monosulfides at 25 °C leads mainly to pyrite and ferric oxides/hydroxides such as

  15. Gas discharge ion source. II. Duopigatron

    International Nuclear Information System (INIS)

    Bacon, F.M.; Bickes, R.W. Jr.; O'Hagan, J.B.

    1978-01-01

    Ion source performance characteristics consisting of total ion current, ion energy distribution, mass distribution, and ion current density distribution have been measured for several models of a duopigatron. Variations on the duopigatron design involved plasma expansion cup material and dimensions, secondary cathode material, and interelectrode spacings. Of the designs tested, the one with a copper and molybdenum secondary cathode, and a mild steel plasma expansion cup proved to give the best results. The ion current density distribution was peaked at the center of the plasma expansion cup and fell off to 80% of the peak value at the cup wall for a cup 15.2 mm deep. A total ion current of 180 mA consisting of 60%-70% atomic ions was produced with an arc current of 20 A and source pressure of 9.3 Pa. More shallow cups produced a larger beam current and a more sharply peaked ion current density distribution. Typical ion energy distributions were bellshaped curves with a peak 10-20 V below anode potential and with ion energies extending 30-40 V on either side of the peak

  16. Dust in H II regions

    International Nuclear Information System (INIS)

    Isobe, S.

    1977-01-01

    Several pieces of evidence indicate that H II regions may contain dust: 1) the continuum light scattered by dust grains (O'Dell and Hubbard, 1965), 2) thermal radiation from dust grains at infrared wavelengths (Ney and Allen, 1969), 3) the abnormal helium abundance in some H II regions (Peimbert and Costero, 1969), etc. Although observations of the scattered continuum suggest that the H II region cores may be dust-free, dust grains and gas must be well mixed in view of the infrared observations. This difficulty may be solved by introducing globules with sizes approximately 0.001 pc. These globules and the molecular clouds adjacent to H II regions are the main sources supplying dust to H II regions. (Auth.)

  17. NSLS-II Radio Frequency Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rose J.; Gao F.; Goel, A.; Holub, B.; Kulpin, J.; Marques, C.; Yeddulla, M.

    2015-05-03

    The National Synchrotron Light Source II is a 3 GeV X-ray user facility commissioned in 2014. The NSLS-II RF system consists of the master oscillator, digital low level RF controllers, linac, booster and storage ring RF sub-systems, as well as a supporting cryogenic system. Here we will report on RF commissioning and early operation experience of the system.

  18. NEWLY IDENTIFIED EXTENDED GREEN OBJECTS (EGOs) FROM THE SPITZER GLIMPSE II SURVEY. II. MOLECULAR CLOUD ENVIRONMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Chen Xi; Gan Conggui; Shen Zhiqiang [Key Laboratory for Research in Galaxies and Cosmology, Shanghai Astronomical Observatory, Chinese Academy of Sciences, Shanghai 200030 (China); Ellingsen, Simon P.; Titmarsh, Anita [School of Mathematics and Physics, University of Tasmania, Hobart, Tasmania (Australia); He Jinhua, E-mail: chenxi@shao.ac.cn [Key Laboratory for the Structure and Evolution of Celestial Objects, Yunnan Astronomical Observatory/National Astronomical Observatory, Chinese Academy of Sciences, P.O. Box 110, Kunming 650011, Yunnan Province (China)

    2013-06-01

    We have undertaken a survey of molecular lines in the 3 mm band toward 57 young stellar objects using the Australia Telescope National Facility Mopra 22 m radio telescope. The target sources were young stellar objects with active outflows (extended green objects (EGOs)) newly identified from the GLIMPSE II survey. We observe a high detection rate (50%) of broad line wing emission in the HNC and CS thermal lines, which combined with the high detection rate of class I methanol masers toward these sources (reported in Paper I) further demonstrates that the GLIMPSE II EGOs are associated with outflows. The physical and kinematic characteristics derived from the 3 mm molecular lines for these newly identified EGOs are consistent with these sources being massive young stellar objects with ongoing outflow activity and rapid accretion. These findings support our previous investigations of the mid-infrared properties of these sources and their association with other star formation tracers (e.g., infrared dark clouds, methanol masers and millimeter dust sources) presented in Paper I. The high detection rate (64%) of the hot core tracer CH{sub 3}CN reveals that the majority of these new EGOs have evolved to the hot molecular core stage. Comparison of the observed molecular column densities with predictions from hot core chemistry models reveals that the newly identified EGOs from the GLIMPSE II survey are members of the youngest hot core population, with an evolutionary time scale of the order of 10{sup 3} yr.

  19. LEVIS ion source and beam characterization on PBFA-II

    International Nuclear Information System (INIS)

    Renk, T.J.; Tisone, G.C.; Adams, R.G.; Bailey, J.E.; Filuk, A.B.; Johnson, D.J.; Pointon, T.D.

    1993-01-01

    We report on the continuing development of the LEVIS (Laser Evaporation Ion Source) lithium active ion source for the 15-cm radial focussing ion diode on PBFA-11. We found previously that DC-heating of the anode surface to 150 degrees C maximum for 5 hours resulted in a pure lithium beam. This paper discusses the characterization of LEVIS source uniformity by Faraday cup arrays and multiple lines of sight for visible light spectroscopy. These diagnostics give some evidence of nonuniformity in both A-K gap electric fields and ion current density. Despite this, however, the measured focal spot size appears smaller than with a passive LiF source operated in the same magnetic field topology. Experiments using a curved anode for vertical beam focussing show reduced ion beam turn-on delay by 5 ns by altering the magnetic field topology as well as anode curvature. Another 3--5 ns reduction was achieved by switching from a passive LiF to the active LEVIS source

  20. From chemolithoautotrophs to electrolithoautotrophs: CO2 fixation by Fe(II)-oxidizing bacteria coupled with direct uptake of electrons from solid electron sources.

    Science.gov (United States)

    Ishii, Takumi; Kawaichi, Satoshi; Nakagawa, Hirotaka; Hashimoto, Kazuhito; Nakamura, Ryuhei

    2015-01-01

    At deep-sea vent systems, hydrothermal emissions rich in reductive chemicals replace solar energy as fuels to support microbial carbon assimilation. Until recently, all the microbial components at vent systems have been assumed to be fostered by the primary production of chemolithoautotrophs; however, both the laboratory and on-site studies demonstrated electrical current generation at vent systems and have suggested that a portion of microbial carbon assimilation is stimulated by the direct uptake of electrons from electrically conductive minerals. Here we show that chemolithoautotrophic Fe(II)-oxidizing bacterium, Acidithiobacillus ferrooxidans, switches the electron source for carbon assimilation from diffusible Fe(2+) ions to an electrode under the condition that electrical current is the only source of energy and electrons. Site-specific marking of a cytochrome aa3 complex (aa3 complex) and a cytochrome bc1 complex (bc1 complex) in viable cells demonstrated that the electrons taken directly from an electrode are used for O2 reduction via a down-hill pathway, which generates proton motive force that is used for pushing the electrons to NAD(+) through a bc1 complex. Activation of carbon dioxide fixation by a direct electron uptake was also confirmed by the clear potential dependency of cell growth. These results reveal a previously unknown bioenergetic versatility of Fe(II)-oxidizing bacteria to use solid electron sources and will help with understanding carbon assimilation of microbial components living in electronically conductive chimney habitats.

  1. The new Munich neutron source

    International Nuclear Information System (INIS)

    Herrmann, W.A.

    1998-01-01

    The Munich FRM II neutron source currently under construction is to replace the FRM I research reactor in Munich, also known as 'atomic egg'. The project is executed by the Free State of Bavaria as a construction project of the Munich Technical University and managed by the University. As main contractor for the construction project, Siemens AG is also co-applicant in the licensing procedure under the Atomic Energy Act for the construction phase. The project is carried out to build a modern high flux neutron source required for a broad range of applications in research and technology mainly with thermal and cold neutrons. The 'neutron gap' existing in Germany is to be closed with the FRM II. As a national research installation, the FRM II is available to all interested scientists from a variety of disciplines. (orig.) [de

  2. RTNS-II fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Tuckerman, D.B.; Davis, J.C.; Massoletti, D.J.; Short, D.W.

    1986-01-01

    The Rotating Target Neutron Source (RTNS-II) facility provides an intense source of 14-MeV neutrons for the fusion energy programs of Japan and the United States. Each of the two identical accelerator-based neutron sources is capable of providing source strengths in excess of 3 x 10 13 n/s using deuteron beam currents up to 150 mA. The present status of the facility, as well as the various upgrade options, will be described in detail

  3. Outer heliospheric radio emissions. II - Foreshock source models

    Science.gov (United States)

    Cairns, Iver H.; Kurth, William S.; Gurnett, Donald A.

    1992-01-01

    Observations of LF radio emissions in the range 2-3 kHz by the Voyager spacecraft during the intervals 1983-1987 and 1989 to the present while at heliocentric distances greater than 11 AU are reported. New analyses of the wave data are presented, and the characteristics of the radiation are reviewed and discussed. Two classes of events are distinguished: transient events with varying starting frequencies that drift upward in frequency and a relatively continuous component that remains near 2 kHz. Evidence for multiple transient sources and for extension of the 2-kHz component above the 2.4-kHz interference signal is presented. The transient emissions are interpreted in terms of radiation generated at multiples of the plasma frequency when solar wind density enhancements enter one or more regions of a foreshock sunward of the inner heliospheric shock. Solar wind density enhancements by factors of 4-10 are observed. Propagation effects, the number of radiation sources, and the time variability, frequency drift, and varying starting frequencies of the transient events are discussed in terms of foreshock sources.

  4. Finding joy in social work. II: Intrapersonal sources.

    Science.gov (United States)

    Pooler, David Kenneth; Wolfer, Terry; Freeman, Miriam

    2014-07-01

    Despite the social work profession's strengths orientation, research on its workforce tends to focus on problems (for example, depression, problem drinking, compassion fatigue, burnout). In contrast, this study explored ways in which social workers find joy in their work. The authors used an appreciative inquiry approach, semistructured interviews (N = 26), and a collaborative grounded theory method of analysis. Participants identified interpersonal (making connections and making a difference) and intrapersonal (making meaning and making a life) sources of joy and reflected significant personal initiative in the process of finding joy. The authors present findings regarding these intrapersonal sources of joy.

  5. The Water Maser in II Zw 96: Scientific Justification

    Energy Technology Data Exchange (ETDEWEB)

    Wiggins, Brandon Kerry [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-06

    We propose a VLBI search to image and locate the water emission in II Zw 96. We propose 3 sites within II Zw 96 for VLBI followup (see the proposed target listing below). We request 2.5 hours of on-source integration time with the VLBA per source. The array will achieve ~ 65µJy sensitivity in K band in this time which will be sufficient to detect luminous water maser features.

  6. Some neutronic calculations for KENS-II

    International Nuclear Information System (INIS)

    Kiyanagi, Y.; Arai, M.; Watanabe, N.

    1989-01-01

    Proton energies of the intense spallation neutron sources currently in operation or designed are in the range Ep ≤ 1.1 GeV. Optimization studies of the target station have so far been performed for these proton energies. The KENS-II project has been included in the Japanese Hadron Facility Project where the proton accelerator, a so-called First Ring is shared with Meson Arena for nuclear physics and μSR experiments. The possible highest proton energy for this accelerator is 2 GeV, which is the highest among the world's spallation neutron sources. The authors, therefore, performed some neutronic calculations with 2 GeV protons in order to have a good knowledge of the neutronic characteristics and the optimal parameters of the target station for KENS-II. The fraction of slow neutron intensity versus the proton energy becomes 0.8 for 2 GeV compared to that for 0.8 GeV, and this is higher than 0.67 calculated for source neutrons. The uranium target has a higher neutron productivity, 1.5 times that of the tungsten target, even for 2 GeV protons. The target radius and the moderator axial position have definite optimal values for 2 GeV protons in spite of the broader distribution of the source neutrons in target, and these are essentially similar to the results for 0.8 GeV protons. The broad distribution with a little increase in the maximum luminosity of source neutrons for 2 GeV protons could make it easier to remove the heat load from the target than the case for the same beam-power with lower energy and higher proton current. Therefore, they could conclude that the 2 GeV protons for KENS-II do not have significant difficulties in producing slow neutrons, and that non-fissile material has higher advantages to produce neutrons for higher proton energies. Detailed neutronic calculations are now under way to design a neutron target station for KENS-II. 5 refs., 10 figs

  7. RTNS-II: present status

    International Nuclear Information System (INIS)

    Heikkinen, D.W.; Logan, C.M.

    1980-10-01

    The present status of the RTNS-II facility is described and typical operating parameters are given. A brief discussion is given of the methods used in production of the TiT 2 targets as well as their performance and tritium handling at RTNS-II. The various types of non-interactive beam diagnostics presently in use at the neutron sources are outlined. The on-line computer system which provides a time history of an irradiation and records target performance is described. Examples are listed of several representative experimental programs which have been carried out thus far at RTNS-II. These include both active and passive experiments. Finally, several of the major improvements to the facility made since the beginning of the experimental program are given

  8. Calculation of spatial distribution of the EURACOS II converter source

    International Nuclear Information System (INIS)

    Santo, A.C.F. de

    1985-01-01

    It is obtained the neutron spatial flux from the EURACOS (Enriched Uranium Converter Source) device, adjusted to experimental measures. The EURACOS device is a converter source which is constituted a circle plate of highly enriched uranium (90%). The converter provides an intense source of fast neutrons which has the energetic spectrum near to the fission spectrum. (M.C.K.) [pt

  9. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    International Nuclear Information System (INIS)

    Muswema, J.L.; Ekoko, G.B.; Lukanda, V.M.; Lobo, J.K.-K.; Darko, E.O.; Boafo, E.K.

    2015-01-01

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  10. Source term derivation and radiological safety analysis for the TRICO II research reactor in Kinshasa

    Energy Technology Data Exchange (ETDEWEB)

    Muswema, J.L., E-mail: jeremie.muswem@unikin.ac.cd [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Ekoko, G.B. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Lukanda, V.M. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Democratic Republic of the Congo' s General Atomic Energy Commission, P.O. Box AE1 (Congo, The Democratic Republic of the); Lobo, J.K.-K. [Faculty of Science, University of Kinshasa, P.O. Box 190, KIN XI (Congo, The Democratic Republic of the); Darko, E.O. [Radiation Protection Institute, Ghana Atomic Energy Commission, P.O. Box LG 80, Legon, Accra (Ghana); Boafo, E.K. [University of Ontario Institute of Technology, 2000 Simcoe St. North, Oshawa, ONL1 H7K4 (Canada)

    2015-01-15

    Highlights: • Atmospheric dispersion modeling for two credible accidents of the TRIGA Mark II research reactor in Kinshasa (TRICO II) was performed. • Radiological safety analysis after the postulated initiating events (PIE) was also carried out. • The Karlsruhe KORIGEN and the HotSpot Health Physics codes were used to achieve the objectives of this study. • All the values of effective dose obtained following the accident scenarios were below the regulatory limits for reactor staff members and the public, respectively. - Abstract: The source term from the 1 MW TRIGA Mark II research reactor core of the Democratic Republic of the Congo was derived in this study. An atmospheric dispersion modeling followed by radiation dose calculation were performed based on two possible postulated accident scenarios. This derivation was made from an inventory of peak radioisotope activities released in the core by using the Karlsruhe version of isotope generation code KORIGEN. The atmospheric dispersion modeling was performed with HotSpot code, and its application yielded to radiation dose profile around the site using meteorological parameters specific to the area under study. The two accident scenarios were picked from possible accident analyses for TRIGA and TRIGA-fueled reactors, involving the case of destruction of the fuel element with highest activity release and a plane crash on the reactor building as the worst case scenario. Deterministic effects of these scenarios are used to update the Safety Analysis Report (SAR) of the reactor, and for its current version, these scenarios are not yet incorporated. Site-specific meteorological conditions were collected from two meteorological stations: one installed within the Atomic Energy Commission and another at the National Meteorological Agency (METTELSAT), which is not far from the site. Results show that in both accident scenarios, radiation doses remain within the limits, far below the recommended maximum effective

  11. A Green Bank Telescope Survey of Large Galactic H II Regions

    Science.gov (United States)

    Anderson, L. D.; Armentrout, W. P.; Luisi, Matteo; Bania, T. M.; Balser, Dana S.; Wenger, Trey V.

    2018-02-01

    As part of our ongoing H II Region Discovery Survey (HRDS), we report the Green Bank Telescope detection of 148 new angularly large Galactic H II regions in radio recombination line (RRL) emission. Our targets are located at a declination of δ > -45^\\circ , which corresponds to 266^\\circ > {\\ell }> -20^\\circ at b=0^\\circ . All sources were selected from the Wide-field Infrared Survey Explorer Catalog of Galactic H II Regions, and have infrared angular diameters ≥slant 260\\prime\\prime . The Galactic distribution of these “large” H II regions is similar to that of the previously known sample of Galactic H II regions. The large H II region RRL line width and peak line intensity distributions are skewed toward lower values, compared with that of previous HRDS surveys. We discover seven sources with extremely narrow RRLs 100 {pc}, making them some of the physically largest known H II regions in the Galaxy. This survey completes the HRDS H II region census in the Northern sky, where we have discovered 887 H II regions and more than doubled the size of the previously known census of Galactic H II regions.

  12. H2O sources in regions of star formation

    International Nuclear Information System (INIS)

    Lo, K.Y.; Burke, B.F.; Haschick, A.D.

    1975-01-01

    Regions and objects believed to be in early stages of stellar formation have been searched for H 2 O 22-GHz line emission with the Haystack 120-foot (37 m) telescope. The objects include radio condensations, infrared objects in H ii regions, and Herbig-Haro objects. Nine new H 2 O sources were detected in the vicinity of such objects, including the Sharpless H ii regions S152, S235, S255, S269, G45.1+0.1, G45.5+0.1, AFCRL infrared object No. 809--2992, and Herbig-Haro objects 1 and 9. The new H 2 O sources detected in H ii regions are associated, but not coincident, with the the radio condensations. Water vapor line emission was detected in approx.25 percent of the regions searched. The association of H 2 O sources with regions of star formation is taken to be real. The spatial relationship of H 2 O sources to infrared objects, radio condensations, class I OH sources, and molecular clouds are discussed. The suggestion is made that an H 2 O source may be excited by a highly obscured star of extreme youth

  13. Calibration of the Accuscan II In Vivo System for I-125 Thyroid Counting

    Energy Technology Data Exchange (ETDEWEB)

    Ovard R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-125 thyroid counting. The source used for the calibration was a DOE manufactured Am-241/Eu-152 source contained in a 22 ml vial BEA Am-241/Eu-152 RMC II-1 with energies from 26 keV to 344 keV. The center of the detector housing was positioned 64 inches from the vault floor. This position places the approximate center line of the detector housing at the center line of the source in the phantom thyroid tube. The energy and efficiency calibration were performed using an RMC II phantom (Appendix J). Performance testing was conducted using source BEA Am-241/Eu-152 RMC II-1 and Validation testing was performed using an I-125 source in a 30 ml vial (I-125 BEA Thyroid 002) and an ANSI N44.3 phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibration including performance verification and validation counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-125 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  14. Using a source-receptor approach to characterise VOC behaviour in a French urban area influenced by industrial emissions. Part II: source contribution assessment using the Chemical Mass Balance (CMB) model.

    Science.gov (United States)

    Badol, Caroline; Locoge, Nadine; Galloo, Jean-Claude

    2008-01-25

    In Part I of this study (Badol C, Locoge N, Leonardis T, Gallo JC. Using a source-receptor approach to characterise VOC behaviour in a French urban area influenced by industrial emissions, Part I: Study area description, data set acquisition and qualitative data analysis of the data set. Sci Total Environ 2007; submitted as companion manuscript.) the study area, acquisition of the one-year data set and qualitative analysis of the data set have been described. In Part II a source profile has been established for each activity present in the study area: 6 profiles (urban heating, solvent use, natural gas leakage, biogenic emissions, gasoline evaporation and vehicle exhaust) have been extracted from literature to characterise urban sources, 7 industrial profiles have been established via canister sampling around industrial plants (hydrocarbon cracking, oil refinery, hydrocarbon storage, lubricant storage, lubricant refinery, surface treatment and metallurgy). The CMB model is briefly described and its implementation is discussed through the selection of source profiles and fitting species. Main results of CMB modellings for the Dunkerque area are presented. (1) The daily evolution of source contributions for the urban wind sector shows that the vehicle exhaust source contribution varies between 40 and 55% and its relative increase at traffic rush hours is hardly perceptible. (2) The relative contribution of vehicle exhaust varies from 55% in winter down to 30% in summer. This decrease is due to the increase of the relative contribution of hydrocarbon storage source reaching up to 20% in summer. (3) The evolution of source contributions with wind directions has confirmed that in urban wind sectors the contribution of vehicle exhaust dominate with around 45-55%. For the other wind sectors that include some industrial plants, the contribution of industrial sources is around 60% and could reach 80% for the sector 280-310 degrees , which corresponds to the most dense

  15. Confined discharge plasma sources for Z-pinch experiments

    International Nuclear Information System (INIS)

    Hinshelwood, D.D.; Goodrich, P.J.; Mehlman, G.; Scherrer, V.E.; Stephanakis, S.J.; Young, F.C.

    1989-01-01

    The authors report their investigation Z-pinch implosions on the NRL Gamble II generator using metallic sources of sodium and aluminum, and non-metallic source of sodium (NaF), magnesium (MgF 2 ), and aluminum (Al 2 0 3 ). For 1 MA driving currents, peak Κ-shell radiated powers of about 100 GW and energies of about 1.5 kj have been obtained with both pure aluminum and NaF implosions. The aluminum results are comparable to those in previous Gamble II experiments with aluminum wire arrays. Confined discharge sources have been used to generate tens of GW in the Na Heα pump line and flourescence of the neon has been observed. The effects of nozzle shape and size, chamber diameter, amount of fuse material, and confined discharge current have been investigated in Gamble II implosion experiments. These studies indicate that confined discharge sources are capable of supplying significantly more material than required for implosions at the 1 MA level, so that this technique could be extended to higher current generators

  16. The Bologna complete sample of nearby radio sources. II. Phase referenced observations of faint nuclear sources

    Science.gov (United States)

    Liuzzo, E.; Giovannini, G.; Giroletti, M.; Taylor, G. B.

    2009-10-01

    Aims: To study statistical properties of different classes of sources, it is necessary to observe a sample that is free of selection effects. To do this, we initiated a project to observe a complete sample of radio galaxies selected from the B2 Catalogue of Radio Sources and the Third Cambridge Revised Catalogue (3CR), with no selection constraint on the nuclear properties. We named this sample “the Bologna Complete Sample” (BCS). Methods: We present new VLBI observations at 5 and 1.6 GHz for 33 sources drawn from a sample not biased toward orientation. By combining these data with those in the literature, information on the parsec-scale morphology is available for a total of 76 of 94 radio sources with a range in radio power and kiloparsec-scale morphologies. Results: The fraction of two-sided sources at milliarcsecond resolution is high (30%), compared to the fraction found in VLBI surveys selected at centimeter wavelengths, as expected from the predictions of unified models. The parsec-scale jets are generally found to be straight and to line up with the kiloparsec-scale jets. A few peculiar sources are discussed in detail. Tables 1-4 are only available in electronic form at http://www.aanda.org

  17. RAiSE II: resolved spectral evolution in radio AGN

    Science.gov (United States)

    Turner, Ross J.; Rogers, Jonathan G.; Shabala, Stanislav S.; Krause, Martin G. H.

    2018-01-01

    The active galactic nuclei (AGN) lobe radio luminosities modelled in hydrodynamical simulations and most analytical models do not address the redistribution of the electron energies due to adiabatic expansion, synchrotron radiation and inverse-Compton scattering of cosmic microwave background photons. We present a synchrotron emissivity model for resolved sources that includes a full treatment of the loss mechanisms spatially across the lobe, and apply it to a dynamical radio source model with known pressure and volume expansion rates. The bulk flow and dispersion of discrete electron packets is represented by tracer fields in hydrodynamical simulations; we show that the mixing of different aged electrons strongly affects the spectrum at each point of the radio map in high-powered Fanaroff & Riley type II (FR-II) sources. The inclusion of this mixing leads to a factor of a few discrepancy between the spectral age measured using impulsive injection models (e.g. JP model) and the dynamical age. The observable properties of radio sources are predicted to be strongly frequency dependent: FR-II lobes are expected to appear more elongated at higher frequencies, while jetted FR-I sources appear less extended. The emerging FR0 class of radio sources, comprising gigahertz peaked and compact steep spectrum sources, can potentially be explained by a population of low-powered FR-Is. The extended emission from such sources is shown to be undetectable for objects within a few orders of magnitude of the survey detection limit and to not contribute to the curvature of the radio spectral energy distribution.

  18. Radiative parameters for some transitions in Cu(II) and Ag(II) spectrum

    International Nuclear Information System (INIS)

    Biemont, E.; Blagoev, K.; Campos, J.; Mayo, R.; Malcheva, G.; Ortiz, M.; Quinet, P.

    2005-01-01

    Radiative parameters for transitions depopulating the levels belonging to the 3d 8 4s 2 configuration of Cu(II) and 4d 9 6s and 4d 9 5d configurations of Ag(II) have been obtained both theoretically and experimentally. On the experimental side, a laser-produced plasma was used as a source of Cu(II) and Ag(II) spectra. The light emitted by the plasma was focused on the input slit of a grating monochromator coupled with a time-resolved optical multichannel analyzer system. Spectral response calibration of the experimental system was made using a deuterium lamp in the wavelength range extending from 200 to 400-bar nm, and a standard tungsten lamp in the range from 350 to 600-bar nm. The transition probabilities were obtained using measured branching fractions and available radiative lifetimes of the corresponding states. On the theoretical side, a relativistic Hartree-Fock (HFR) approach, including core-polarization effects, has been used for the calculations. A reasonable agreement theory-experiment has been observed

  19. Next-generation mid-infrared sources

    Science.gov (United States)

    Jung, D.; Bank, S.; Lee, M. L.; Wasserman, D.

    2017-12-01

    The mid-infrared (mid-IR) is a wavelength range with a variety of technologically vital applications in molecular sensing, security and defense, energy conservation, and potentially in free-space communication. The recent development and rapid commercialization of new coherent mid-infrared sources have spurred significant interest in the development of mid-infrared optical systems for the above applications. However, optical systems designers still do not have the extensive optical infrastructure available to them that exists at shorter wavelengths (for instance, in the visible and near-IR/telecom wavelengths). Even in the field of optoelectronic sources, which has largely driven the growing interest in the mid-infrared, the inherent limitations of state-of-the-art sources and the gaps in spectral coverage offer opportunities for the development of new classes of lasers, light emitting diodes and emitters for a range of potential applications. In this topical review, we will first present an overview of the current state-of-the-art mid-IR sources, in particular thermal emitters, which have long been utilized, and the relatively new quantum- and interband-cascade lasers, as well as the applications served by these sources. Subsequently, we will discuss potential mid-infrared applications and wavelength ranges which are poorly served by the current stable of mid-IR sources, with an emphasis on understanding the fundamental limitations of the current source technology. The bulk of the manuscript will then explore both past and recent developments in mid-infrared source technology, including narrow bandgap quantum well lasers, type-I and type-II quantum dot materials, type-II superlattices, highly mismatched alloys, lead-salts and transition-metal-doped II-VI materials. We will discuss both the advantages and limitations of each of the above material systems, as well as the potential new applications which they might serve. All in all, this topical review does not aim

  20. Plasma opening switch development for the Particle Beam Fusion Accelerator II (PBFA II)

    International Nuclear Information System (INIS)

    Stinnett, R.W.; McDaniel, D.H.; Rochau, G.E.

    1987-01-01

    The authors conducted plasma opening switch (POS) experiments on Sandia National Laboratories' new Particle Beam Fusin Accelerator II (PBFA II) (12 MV, 100 TW, 50 ns), on the Supermite accelerator (2 MV, 2 TW, 50 ns) and on the Naval Research Laboratory's Gamble II accelerator (1.8 MV, 1.6 TW, 70 ns). The POS systems on the PBFA II and Supermite accelerators use a newly developed flashboard plasma source to provide the plasma necessary to conduct the large (> 1 MA) currents produced byu these accelerators. In the Supermite experiments, the plasma opening switch conducted currents up to 1 MA before opening in less than 10 ns into an electron beam load. These experiments achieved significant voltage gain relative to the voltage across a matched load. In experiments on Gamble II, power gains of up to 1.7 were achieved using a POS in a strongly coaxial geometry (r/sub outer//r/sub inner/ = 2) with a large magnetic field at the cathode. The POS system on PBFA II is unique because of its size and voltage. This POS system is designed to conduct over 6 MA before opening. In present experiments it has conducted currents of 4-5 MA for over 50 ns

  1. 4C radio sources in clusters of galaxies

    International Nuclear Information System (INIS)

    McHardy, I.M.

    1979-01-01

    Observations of a complete sample of 4C and 4CT radio sources in Abell clusters with the Cambridge One-Mile telescope are analysed. It is concluded that radio sources are strongly concentrated towards the cluster centres and are equally likely to be found in clusters of any richness. The probability of a galaxy of a given absolute magnitude producing a source above a given luminosity does not depend on cluster membership. 4C and 4CT radio sources in clusters, selected at 178 MHz, occur preferentially in Bautz-Morgan (BM) class 1 clusters, whereas those selected at 1.4 GHz do not. The most powerful radio source in the cluster is almost always associated with the optically brightest galaxy. The average spectrum of 4C sources in the range 408 to 1407 MHz is steeper in BM class 1 than in other classes. Spectra also steepen with cluster richness. the morphology of 4C sources in clusters depends strongly on BM class and, in particular, radio-trail sources occur only in BM classes II, II-III and III. (author)

  2. Effect of temperature on the optical and structural properties of hexadecylamine capped ZnS nanoparticles using Zinc(II) N-ethyl-N-phenyldithiocarbamate as single source precursor

    Energy Technology Data Exchange (ETDEWEB)

    Onwudiwe, Damian C., E-mail: dconwudiwe@webmail.co.za [Chemical Resource Beneficiation, North-West University, Private Bag X6001, Potchefstroom 2520 (South Africa); Strydom, Christien [Chemical Resource Beneficiation, North-West University, Private Bag X6001, Potchefstroom 2520 (South Africa); Oluwafemi, Oluwatobi S., E-mail: oluwafemi.oluwatobi@gmail.com [Department of Chemistry and Chemical Technology, Walter Sisulu University, Mthatha Campus, Private Bag X1, Mthatha (South Africa); Songca, Sandile P. [Faculty of Science, Engineering and Technology, Walter Sisulu University, P.O. Box 19712, Tecoma, East London (South Africa)

    2012-12-15

    Graphical abstract: Display Omitted Highlights: ► HDA-capped ZnS nanoparticles were synthesized via thermolysis of a single source precursor. ► Zinc(II) N-ethyl-N-phenyldithiocarbamate was used as the single source precursor. ► The growth temperature was varied to study the optical properties of the nanocrystals. ► Change in growth temperature affects the structural properties of the ZnS nanoparticles. ► Hexagonal wurtzite phase was obtained at lower temperatures while cubic sphalerite phase was obtained at higher growth temperatures. -- Abstract: Reported in this work is the synthesis of HDA (hexadecylamine)-capped ZnS nanoparticles by a single source route using Zinc(II) N-ethyl-N-phenyldithiocarbamate as a precursor. By varying the growth temperature, the temporal evolution of the optical properties and morphology of the nanocrystals were investigated. The as-synthesized nanoparticles were characterized using UV–vis absorption and photoluminescence (PL) spectroscopy, transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD). All the particles exhibited quantum confinement in their optical properties with band edge emission at the early stage of the reaction. The XRD showed transition from hexagonal wurtzite phase to cubic sphalerite phase as the growth temperature increases. The TEM image showed that the particles are small and spherical in shape while the HRTEM image confirmed the crystalline nature of the material.

  3. SEISRISK II; a computer program for seismic hazard estimation

    Science.gov (United States)

    Bender, Bernice; Perkins, D.M.

    1982-01-01

    The computer program SEISRISK II calculates probabilistic ground motion values for use in seismic hazard mapping. SEISRISK II employs a model that allows earthquakes to occur as points within source zones and as finite-length ruptures along faults. It assumes that earthquake occurrences have a Poisson distribution, that occurrence rates remain constant during the time period considered, that ground motion resulting from an earthquake is a known function of magnitude and distance, that seismically homogeneous source zones are defined, that fault locations are known, that fault rupture lengths depend on magnitude, and that earthquake rates as a function of magnitude are specified for each source. SEISRISK II calculates for each site on a grid of sites the level of ground motion that has a specified probability of being exceeded during a given time period. The program was designed to process a large (essentially unlimited) number of sites and sources efficiently and has been used to produce regional and national maps of seismic hazard.}t is a substantial revision of an earlier program SEISRISK I, which has never been documented. SEISRISK II runs considerably [aster and gives more accurate results than the earlier program and in addition includes rupture length and acceleration variability which were not contained in the original version. We describe the model and how it is implemented in the computer program and provide a flowchart and listing of the code.

  4. Safety analysis of a pool Genesis II irradiator

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de A.

    2011-01-01

    The Genesis II Irradiator manufactured by GRAT * STAR Inc. (USA) is a category III gamma irradiator in which the sealed source is contained in a water filled storage pool and is shielded permanently, i.e. the material has to move down to the source. Even though the pool is 5.6 m deep, what would happen if the water level lowered? There are a series of safety devices that will avoid this situation and calculations show that the water level has to be very low in order to deliver a significant dose; moreover, only in case a person remains at the border of the pool for a long time this would be risky. In conclusion, it is practically impossible for someone to be exposed to radiation from a Genesis II Irradiator source. (author)

  5. An evolutionary link between Seyfert I and II galaxies

    International Nuclear Information System (INIS)

    Penston, M.V.; Perez, E.

    1984-01-01

    First spectra from the newly sited Isaac Newton Telescope show NGC 4151 and 3C 390.3 to have taken on a classification very close to Seyfert II. It is proposed that Seyfert II galaxies are Seyfert Is in which the continuum source is temporarily off. (author)

  6. FRM-II: status of construction, licensing fuel tests

    International Nuclear Information System (INIS)

    Axmann, A.; Boening, K.; Nuding, M.; Didier, H.J.

    2001-01-01

    The research reactor FRM-II of the Technische Universitaet Muenchen is now ready for the nuclear start-up, but still waiting for the operational license. The high-flux neutron-source FRM-II (8 x 10 14 n/(s cm 2 ) is a unique tool for solid state physics and materials research by neutron scattering, positron annihilation experiments and activation analysis, as well as for fundamental physics, isotope production, silicone doping, cancer therapy by irradiation with fission neutrons and for tomography with fast and thermal neutrons. Reactor built in facilities as a hot source, a cold source, an uranium loaded converter plate producing an intense beam of fission neutrons, allow to expand the range of usable neutron energies far beyond the thermal spectrum. In addition, a source providing an intense beam of fission products is planned to be constructed by the Ludwig-Maximilians-Universitaet Muenchen and a source of ultra cold neutrons is planned by the Physics Department of the Technische Universitaet Muenchen. The reactor is already prepared for both of these facilities. (author)

  7. The alkaline aluminium/hydrogen peroxide power source in the Hugin II unmanned underwater vehicle

    Science.gov (United States)

    Hasvold, Øistein; Johansen, Kjell Håvard; Mollestad, Ole; Forseth, Sissel; Størkersen, Nils

    In 1993, The Norwegian Defence Research Establishment (FFI) demonstrated AUV-Demo, an unmanned (untethered) underwater vehicle (UUV), powered by a magnesium/dissolved oxygen seawater battery (SWB). This technology showed that an underwater range of at least 1000 nautical miles at a speed of 4 knots was possible, but also that the maximum hotel load this battery system could support was very limited. Most applications for UUV technology need more power over a shorter period of time. Seabed mapping using a multibeam echo sounder mounted on an UUV was identified as a viable application and the Hugin project was started in 1995 in cooperation with Norwegian industry. For this application, an endurance of 36 h at 4 knots was required. Development of the UUV hull and electronics system resulted in the UUV Hugin I. It carries a Ni/Cd battery of 3 kW h, allowing up to 6 h under-water endurance. In parallel, we developed a battery based on a combination of alkaline Al/air and SWB technology, using a circulating alkaline electrolyte, aluminium anodes and maintaining the oxidant concentration in the electrolyte by continuously adding hydrogen peroxide (HP) to the electrolyte. This concept resulted in a safe battery, working at ambient pressure (balanced) and with sufficient power and energy density to allow the UUV Hugin II to make a number of successive dives, each of up to 36 h duration and with only 1 h deck time between dives for HP refill and electrolyte exchange. After 100 h, an exchange of anodes takes place. The power source consists of a four-cell Al/HP battery, a DC/DC converter delivering 600 W at 30 V, circulation and dosing pumps and a battery control unit. Hugin II is now in routine use by the Norwegian Underwater Intervention AS (NUI) which operates the UUV for high-precision seabed mapping down to a water depth of 600 m.

  8. Assessment of dynamic energy conversion systems for radioisotope heat sources

    International Nuclear Information System (INIS)

    Thayer, G.R.; Mangeng, C.A.

    1985-06-01

    The use of dynamic conversion systems to convert the heat generated in a 7500 W(t) 90 Sr radioisotopic heat source to electricity is examined. The systems studies were Stirling; Brayton Cycle; three organic Rankines (ORCs) (Barber-Nichols/ORMAT, Sundstrand, and TRW); and an organic Rankine plus thermoelectrics. The systems were ranked for a North Warning System mission using a Los Alamos Multiattribute Decision Theory code. Three different heat source designs were used: case I with a beginning of life (BOL) source temperature of 640 C, case II with a BOL source temperature of 745 0 C, and case III with a BOL source temperature of 945 0 C. The Stirling engine system was the top-ranked system of cases I and II, closely followed by the ORC systems in case I and ORC plus thermoelectrics in case II. The Brayton cycle system was top-ranked for case III, with the Stirling engine system a close second. The use of 238 Pu in heat source sizes of 7500 W(t) was examined and found to be questionable because of cost and material availability and because of additional requirements for analysis of safeguards and critical mass

  9. 318-MHz variability of complete samples of extragalactic radio sources. II

    International Nuclear Information System (INIS)

    Dennison, B.; Broderick, J.J.; Ledden, J.E.; O'Dell, S.L.; Condon, J.J.

    1981-01-01

    We report the remainder of two- and three-epoch 318-MHz observations of extragalactic sources in samples complete to 3 Jy at 1400 MHz and 1 Jy at 5000 MHz. From analysis of this low-frequency variability survey, we find that steep-spectrum (α> or =0.5) sources do not appear to vary, but about 40% of all flat-spectrum (α<0.5) sources exhibit low-frequency variability exceeding 8% over approx.5 yr. Among the flat-spectrum sources, those with inverted spectra show the largest fractional variations. We also find that the incidence of low-frequency variability is strongly correlated with the determination that a source is an optically violent variable. These statistical properties are consistent with models invoking relativistic beaming of radio and optical emission

  10. High resolution far-infrared observations of the evolved H II region M16

    International Nuclear Information System (INIS)

    McBreen, B.; Fazio, G.G.; Jaffe, D.T.

    1982-01-01

    M16 is an evolved, extremely density bounded H II region, which now consists only of a series of ionization fronts at molecular cloud boundaries. The source of ionization is the OB star cluster (NGC 6611) which is about 5 x 10 6 years old. We used the CFA/UA 102 cm balloon-borne telescope to map this region and detected three far-infrared (far-IR) sources embedded in an extended ridge of emission. Source I is an unresolved far-IR source embedded in a molecular cloud near a sharp ionization front. An H 2 O maser is associated with this source, but no radio continuum emission has been observed. The other two far-IR sources (II and III) are associated with ionized gas-molecular cloud interfaces, with the far-IR radiation arising from dust at the boundary heated by the OB cluster. Source II is located at the southern prominent neutral intrusion with its associated bright rims and dark ''elephant trunk'' globules that delineate the current progress of the ionization front into the neutral material, and Source III arises at the interface of the northern molecular cloud fragment

  11. Star Formation and Young Population of the H II Complex Sh2-294

    Science.gov (United States)

    Samal, M. R.; Pandey, A. K.; Ojha, D. K.; Chauhan, N.; Jose, J.; Pandey, B.

    2012-08-01

    The Sh2-294 H II region ionized by a single B0V star features several infrared excess sources, a photodissociation region, and also a group of reddened stars at its border. The star formation scenario in this region seems to be quite complex. In this paper, we present follow-up results of Sh2-294 H II region at 3.6, 4.5, 5.8, and 8.0 μm observed with the Spitzer Space Telescope Infrared Array Camera (IRAC), coupled with H2 (2.12 μm) observation, to characterize the young population of the region and to understand its star formation history. We identified 36 young stellar object (YSO, Class I, Class II, and Class I/II) candidates using IRAC color-color diagrams. It is found that Class I sources are preferentially located at the outskirts of the H II region and associated with enhanced H2 emission; none of them are located near the central cluster. Combining the optical to mid-infrared (MIR) photometry of the YSO candidates and using the spectral energy distribution fitting models, we constrained stellar parameters and the evolutionary status of 33 YSO candidates. Most of them are interpreted by the model as low-mass (<4 M ⊙) YSOs; however, we also detected a massive YSO (~9 M ⊙) of Class I nature, embedded in a cloud of visual extinction of ~24 mag. Present analysis suggests that the Class I sources are indeed a younger population of the region relative to Class II sources (age ~ 4.5 × 106 yr). We suggest that the majority of the Class I sources, including the massive YSOs, are second-generation stars of the region whose formation is possibly induced by the expansion of the H II region powered by a ~4 × 106 yr B0 main-sequence star.

  12. STAR FORMATION AND YOUNG POPULATION OF THE H II COMPLEX Sh2-294

    International Nuclear Information System (INIS)

    Samal, M. R.; Pandey, A. K.; Chauhan, N.; Jose, J.; Ojha, D. K.; Pandey, B.

    2012-01-01

    The Sh2-294 H II region ionized by a single B0V star features several infrared excess sources, a photodissociation region, and also a group of reddened stars at its border. The star formation scenario in this region seems to be quite complex. In this paper, we present follow-up results of Sh2-294 H II region at 3.6, 4.5, 5.8, and 8.0 μm observed with the Spitzer Space Telescope Infrared Array Camera (IRAC), coupled with H 2 (2.12 μm) observation, to characterize the young population of the region and to understand its star formation history. We identified 36 young stellar object (YSO, Class I, Class II, and Class I/II) candidates using IRAC color-color diagrams. It is found that Class I sources are preferentially located at the outskirts of the H II region and associated with enhanced H 2 emission; none of them are located near the central cluster. Combining the optical to mid-infrared (MIR) photometry of the YSO candidates and using the spectral energy distribution fitting models, we constrained stellar parameters and the evolutionary status of 33 YSO candidates. Most of them are interpreted by the model as low-mass ( ☉ ) YSOs; however, we also detected a massive YSO (∼9 M ☉ ) of Class I nature, embedded in a cloud of visual extinction of ∼24 mag. Present analysis suggests that the Class I sources are indeed a younger population of the region relative to Class II sources (age ∼ 4.5 × 10 6 yr). We suggest that the majority of the Class I sources, including the massive YSOs, are second-generation stars of the region whose formation is possibly induced by the expansion of the H II region powered by a ∼4 × 10 6 yr B0 main-sequence star.

  13. 10.-14. II on Puhta Rõõmu alaliiduna tuntud...

    Index Scriptorium Estoniae

    2004-01-01

    Lõkerdus- ja tegevuskunstikollektiiv Naeruorgesster ehk Laffing ahkestra - dirigent Erki Kannus, lõkerdajad Ivika Kivi, Piret Räni, Merle Kannus, Maris Mändel, Marge Monko, Aino Sepp, Annika Kaljurand, Anya Ronacher - esines 11. II Stockholmis Moderna Museeti taasavamispidustuste raames, 12. II osaleti tegevuskunstiprogrammis "Source Live 2004". Aprillis oodatakse kollektiivi Varssavisse Zacheta galerii näitusele "Poisid ja tüdrukud" (16. II-4. IV), kus esitatakse Piret Räni ja Anu Vahtra videot "Punk.Fem.Collection"

  14. Studying the highly bent spectra of FR II-type radio galaxies with the KDA EXT model

    Science.gov (United States)

    Kuligowska, Elżbieta

    2018-04-01

    Context. The Kaiser, Dennett-Thorpe & Alexander (KDA, 1997, MNRAS, 292, 723) EXT model, that is, the extension of the KDA model of Fanaroff & Riley (FR) II-type source evolution, is applied and confronted with the observational data for selected FR II-type radio sources with significantly aged radio spectra. Aim. A sample of FR II-type radio galaxies with radio spectra strongly bent at their highest frequencies is used for testing the usefulness of the KDA EXT model. Methods: The dynamical evolution of FR II-type sources predicted with the KDA EXT model is briefly presented and discussed. The results are then compared to the ones obtained with the classical KDA approach, assuming the source's continuous injection and self-similarity. Results: The results and corresponding diagrams obtained for the eight sample sources indicate that the KDA EXT model predicts the observed radio spectra significantly better than the best spectral fit provided by the original KDA model.

  15. NSLS-II Digital RF Controller Logic and Applications

    Energy Technology Data Exchange (ETDEWEB)

    Holub, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gao, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Kulpin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Marques, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Oliva, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rose, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Towne, N. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    The National Synchrotron Light Source II (NSLS-II) accelerator consists of the Storage Ring, the Booster Ring and Linac along with their associated cavities. Given the number, types and variety of functions of these cavities, we sought to limit the logic development effort by reuse of parameterized code on one hardware platform. Currently there are six controllers installed in the NSLS-II system. There are two in the Storage ring, two in the Booster ring, one in the Linac and one in the Master Oscillator Distribution system.

  16. Performance Characterization of LCLS-II Superconducting Radiofrequency Cryomodules

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, RuthAnn [Michigan State Univ., East Lansing, MI (United States)

    2017-11-10

    This paper will describe the LCLS (Linac Coherent Light Source)-II, Fermilab’s role in the development of LCLS-II, and my contributions as a Lee Teng intern. LCLS-II is a second generation x-ray free electron laser being constructed at SLAC National Accelerator Laboratory. Fermilab is responsible for the design, construction, and testing of several 1.3 GHz cryomodules to be used in LCLS-II. These cryomodules are currently being tested at Fermilab. Some software was written to analyze the data from the cryomodule tests. This software assesses the performance of the cryomodules by looking at data on the cavity voltage, cavity gradient, dark current, and radiation.

  17. AN IN-DEPTH VIEW OF THE MID-INFRARED PROPERTIES OF POINT SOURCES AND THE DIFFUSE ISM IN THE SMC GIANT H II REGION, N66

    International Nuclear Information System (INIS)

    Whelan, David G.; Johnson, Kelsey E.; Indebetouw, Rémy; Lebouteiller, Vianney; Galliano, Frédéric; Peeters, Els; Bernard-Salas, Jeronimo; Brandl, Bernhard R.

    2013-01-01

    The focus of this work is to study mid-infrared point sources and the diffuse interstellar medium (ISM) in the low-metallicity (∼0.2 Z ☉ ) giant H II region N66 in order to determine properties that may shed light on star formation in these conditions. Using the Spitzer Space Telescope's Infrared Spectrograph, we study polycyclic aromatic hydrocarbon (PAH), dust continuum, silicate, and ionic line emission from 14 targeted infrared point sources as well as spectra of the diffuse ISM that is representative of both the photodissociation regions (PDRs) and the H II regions. Among the point source spectra, we spectroscopically confirm that the brightest mid-infrared point source is a massive embedded young stellar object, we detect silicates in emission associated with two young stellar clusters, and we see spectral features of a known B[e] star that are commonly associated with Herbig Be stars. In the diffuse ISM, we provide additional evidence that the very small grain population is being photodestroyed in the hard radiation field. The 11.3 μm PAH complex emission exhibits an unexplained centroid shift in both the point source and ISM spectra that should be investigated at higher signal-to-noise and resolution. Unlike studies of other regions, the 6.2 μm and 7.7 μm band fluxes are decoupled; the data points cover a large range of I 7.7 /I 11.3 PAH ratio values within a narrow band of I 6.2 /I 11.3 ratio values. Furthermore, there is a spread in PAH ionization, being more neutral in the dense PDR where the radiation field is relatively soft, but ionized in the diffuse ISM/PDR. By contrast, the PAH size distribution appears to be independent of local ionization state. Important to unresolved studies of extragalactic low-metallicity star-forming regions, we find that emission from the infrared-bright point sources accounts for only 20%-35% of the PAH emission from the entire region. These results make a comparative data set to other star-forming regions with

  18. Developments in Polarization and Energy Control of APPLE-II Undulators at Diamond Light Source

    Science.gov (United States)

    Longhi, E. C.; Bencok, P.; Dobrynin, A.; Rial, E. C. M.; Rose, A.; Steadman, P.; Thompson, C.; Thomson, A.; Wang, H.

    2013-03-01

    A pair of 2m long APPLE-II type undulators have been built for the I10 BLADE beamline at Diamond Light Source. These 48mm period devices have gap as well as four moveable phase axes which provide the possibility to produce the full range of elliptical polarizations as well as linear polarization tilted through a full 180deg. The mechanical layout chosen has a 'master and slave' arrangement of the phase axes on the top and bottom. This arrangement allows the use of symmetries to provide operational ease for both changing energy using only the master phase while keeping fixed linear horizontal or circular polarization, as well as changing linear polarization angle while keeping fixed energy [1]. The design allows very fast motion of the master phase arrays, without sacrifice of accuracy, allowing the possibility of mechanical polarization switching at 1Hz for dichroism experiments. We present the mechanical design features of these devices, as well as the results of magnetic measurements and shimming from before installation. Finally, we present the results of characterization of these devices by the beamline, including polarimetry, which has been done on the various modes of motion to control energy and polarization. These modes of operation have been available to users since 2011.

  19. Developments in Polarization and Energy Control of APPLE-II Undulators at Diamond Light Source

    International Nuclear Information System (INIS)

    Longhi, E C; Bencok, P; Dobrynin, A; Rial, E C M; Rose, A; Steadman, P; Thompson, C; Thomson, A; Wang, H

    2013-01-01

    A pair of 2m long APPLE-II type undulators have been built for the I10 BLADE beamline at Diamond Light Source. These 48mm period devices have gap as well as four moveable phase axes which provide the possibility to produce the full range of elliptical polarizations as well as linear polarization tilted through a full 180deg. The mechanical layout chosen has a 'master and slave' arrangement of the phase axes on the top and bottom. This arrangement allows the use of symmetries to provide operational ease for both changing energy using only the master phase while keeping fixed linear horizontal or circular polarization, as well as changing linear polarization angle while keeping fixed energy [1]. The design allows very fast motion of the master phase arrays, without sacrifice of accuracy, allowing the possibility of mechanical polarization switching at 1Hz for dichroism experiments. We present the mechanical design features of these devices, as well as the results of magnetic measurements and shimming from before installation. Finally, we present the results of characterization of these devices by the beamline, including polarimetry, which has been done on the various modes of motion to control energy and polarization. These modes of operation have been available to users since 2011.

  20. 238Pu sources for cardiac pacemakers. II. Control

    International Nuclear Information System (INIS)

    Pottier, R.; Merigot, S.

    1976-01-01

    The method and the apparatus used for thermal (power) and radioactive control of radioisotopic sources for pacemakers are briefly described. The cybernetic system is also presented, which assumes almost automatically the monitoring of control, mechanical and electronic works, data processing, the measurements and computations, and the works related to quality control [fr

  1. Time-dependent, Bianchi II, rotating universe

    International Nuclear Information System (INIS)

    Reboucas, M.J.

    1981-01-01

    An exact cosmological solution of Einstein's equations which has time-dependent rotation is presented. The t-constant sections are of Bianchi type II. The source of this geometry is a fluid which has not been thermalized. (Author) [pt

  2. THE GREEN BANK TELESCOPE H II REGION DISCOVERY SURVEY. III. KINEMATIC DISTANCES

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, L. D. [Department of Physics, West Virginia University, Morgantown, WV 26506 (United States); Bania, T. M. [Institute for Astrophysical Research, Department of Astronomy, Boston University, 725 Commonwealth Avenue, Boston, MA 02215 (United States); Balser, Dana S. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903-2475 (United States); Rood, Robert T., E-mail: Loren.Anderson@mail.wvu.edu [Astronomy Department, University of Virginia, P.O. Box 3818, Charlottesville, VA 22903-0818 (United States)

    2012-07-20

    Using the H I emission/absorption method, we resolve the kinematic distance ambiguity and derive distances for 149 of 182 (82%) H II regions discovered by the Green Bank Telescope H II Region Discovery Survey (GBT HRDS). The HRDS is an X-band (9 GHz, 3 cm) GBT survey of 448 previously unknown H II regions in radio recombination line and radio continuum emission. Here, we focus on HRDS sources from 67 Degree-Sign {>=} l {>=} 18 Degree-Sign , where kinematic distances are more reliable. The 25 HRDS sources in this zone that have negative recombination line velocities are unambiguously beyond the orbit of the Sun, up to 20 kpc distant. They are the most distant H II regions yet discovered. We find that 61% of HRDS sources are located at the far distance, 31% at the tangent-point distance, and only 7% at the near distance. 'Bubble' H II regions are not preferentially located at the near distance (as was assumed previously) but average 10 kpc from the Sun. The HRDS nebulae, when combined with a large sample of H II regions with previously known distances, show evidence of spiral structure in two circular arc segments of mean Galactocentric radii of 4.25 and 6.0 kpc. We perform a thorough uncertainty analysis to analyze the effect of using different rotation curves, streaming motions, and a change to the solar circular rotation speed. The median distance uncertainty for our sample of H II regions is only 0.5 kpc, or 5%. This is significantly less than the median difference between the near and far kinematic distances, 6 kpc. The basic Galactic structure results are unchanged after considering these sources of uncertainty.

  3. Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II ...

    Indian Academy of Sciences (India)

    Unknown

    Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II) Schiff base complexes derived from o-phenylenediamine and acetoacetanilide. N RAMAN*, Y PITCHAIKANI RAJA and A KULANDAISAMY. Department of Chemistry, VHNSN College, Virudhunagar 626 001, India e-mail: ra_man@123india.com.

  4. Biologically active new Fe(II, Co(II, Ni(II, Cu(II, Zn(II and Cd(II complexes of N-(2-thienylmethylenemethanamine

    Directory of Open Access Journals (Sweden)

    C. SPÎNU

    2008-04-01

    Full Text Available Iron(II, cobalt(II, nickel (II, copper (II, zinc(II and cadmium(II complexes of the type ML2Cl2, where M is a metal and L is the Schiff base N-(2-thienylmethylenemethanamine (TNAM formed by the condensation of 2-thiophenecarboxaldehyde and methylamine, were prepared and characterized by elemental analysis as well as magnetic and spectroscopic measurements. The elemental analyses suggest the stoichiometry to be 1:2 (metal:ligand. Magnetic susceptibility data coupled with electronic, ESR and Mössbauer spectra suggest a distorted octahedral structure for the Fe(II, Co(II and Ni(II complexes, a square-planar geometry for the Cu(II compound and a tetrahedral geometry for the Zn(II and Cd(II complexes. The infrared and NMR spectra of the complexes agree with co-ordination to the central metal atom through nitrogen and sulphur atoms. Conductance measurements suggest the non-electrolytic nature of the complexes, except for the Cu(II, Zn(II and Cd(II complexes, which are 1:2 electrolytes. The Schiff base and its metal chelates were screened for their biological activity against Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa and the metal chelates were found to possess better antibacterial activity than that of the uncomplexed Schiff base.

  5. An assessment of dynamic energy conversion systems for terrestrial radioisotope heat sources

    International Nuclear Information System (INIS)

    Thayer, G.R.

    1985-01-01

    The use of dynamic conversion systems to convert to electricity the heat generated in a 7500 W(t) 90 Sr radioisotopic heat source is examined. Brayton Cycle, three Organic Rankine systems (Barber-Nichols/ORMAT, Sundstrand, and TRW concepts), Organic Rankine plus thermoelectrics, and Stirling Engine systems were studied. The systems were ranked for a North Warning System mission using a Los Alamos Multi-Attribute Decision Theory code. Three different heat source designs were used: Case I with a beginning of life (BOL) source temperature of 640 0 C, Case II with a BOL source temperature of 745 0 C, and Case III with a BOL source temperature of 945 0 C. The Stirling Engine system was the top-ranked system for Cases I and II, closely followed by the ORC systems in Case I and ORC and thermoelectrics in Case II. The Brayton-Cycle system was top-ranked for Case III, with the Stirling Engine system a close second

  6. PIP-II Injector Test: Challenges and Status

    Energy Technology Data Exchange (ETDEWEB)

    Derwent, P. F. [Fermilab; Carneiro, J. P. [Fermilab; Edelen, J. [Fermilab; Lebedev, V. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Shemyakin, A. [Fermilab; Steimel, J. [Fermilab

    2016-10-04

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H- superconducting RF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the Injector Test warm front end, including results of the beam commissioning through the installed components, and progress with SRF cryomodules and other systems.

  7. Advanced neutron instrumentation at FRM-II

    International Nuclear Information System (INIS)

    Petry, Winfried

    2003-01-01

    The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these instruments are unique, others are expected to be the best of their kind, all instruments are based on innovative techniques. (author)

  8. RF H-minus ion source development in China spallation neutron source

    Science.gov (United States)

    Chen, W.; Ouyang, H.; Xiao, Y.; Liu, S.; Lü, Y.; Cao, X.; Huang, T.; Xue, K.

    2017-08-01

    China Spallation Neutron Source (CSNS) phase-I project currently uses a Penning surface plasma H- ion source, which has a life time of several weeks with occasional sparks between high voltage electrodes. To extend the life time of the ion source and prepare for the CSNS phase-II, we are trying to develop a RF negative hydrogen ion source with external antenna. The configuration of the source is similar to the DESY external antenna ion source and SNS ion source. However several changes are made to improve the stability and the life time. Firstly, Si3N4 ceramic with high thermal shock resistance, and high thermal conductivity is used for plasma chamber, which can endure an average power of 2000W. Secondly, the water-cooled antenna is brazed on the chamber to improve the energy efficiency. Thirdly, cesium is injected directly to the plasma chamber if necessary, to simplify the design of the converter and the extraction. Area of stainless steel exposed to plasma is minimized to reduce the sputtering and degassing. Instead Mo, Ta, and Pt coated materials are used to face the plasma, which makes the self-cleaning of the source possible.

  9. Complexes of cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and dioxouranium(II) with thiophene-2-aldehydethiosemicarbazone

    International Nuclear Information System (INIS)

    Singh, Balwan; Misra, Harihar

    1986-01-01

    Metal complexes of thiosemicarbazides have been known for their pharmacological applications. Significant antitubercular, fungicidal and antiviral activities have been reported for thiosemicarbazides and their derivatives. The present study describes the systhesis and characterisation of complexes of Co II , Cu II , Zn II ,Cd II and UO II with thiosemicarbazone obtained by condensing thiophene-2-aldehyde with thiosemicarbazide. 17 refs., 2 tables. (author)

  10. Calibration of the Accuscan II In Vivo System for I-131 Thyroid Counting

    Energy Technology Data Exchange (ETDEWEB)

    Orval R. Perry; David L. Georgeson

    2011-07-01

    This report describes the March 2011 calibration of the Accuscan II HpGe In Vivo system for I-131 thyroid counting. The source used for the calibration was an Analytics mixed gamma source 82834-121 distributed in an epoxy matrix in a Wheaton Liquid Scintillation Vial with energies from 88.0 keV to 1836.1 keV. The center of the detectors was position 64-feet from the vault floor. This position places the approximate center line of the detectors at the center line of the source in the thyroid tube. The calibration was performed using an RMC II phantom (Appendix J). Validation testing was performed using a Ba-133 source and an ANSI N44.3 Phantom (Appendix I). This report includes an overview introduction and records for the energy/FWHM and efficiency calibrations including verification counting. The Accuscan II system was successfully calibrated for counting the thyroid for I-131 and verified in accordance with ANSI/HPS N13.30-1996 criteria.

  11. SPITZER VIEW OF YOUNG MASSIVE STARS IN THE LARGE MAGELLANIC CLOUD H II COMPLEXES. II. N 159

    International Nuclear Information System (INIS)

    Chen, C.-H. Rosie; Indebetouw, Remy; Chu, You-Hua; Gruendl, Robert A.; Seale, Jonathan P.; Testor, Gerard; Heitsch, Fabian; Meixner, Margaret; Sewilo, Marta

    2010-01-01

    The H II complex N 159 in the Large Magellanic Cloud is used to study massive star formation in different environments, as it contains three giant molecular clouds (GMCs) that have similar sizes and masses but exhibit different intensities of star formation. We identify candidate massive young stellar objects (YSOs) using infrared photometry, and model their spectral energy distributions to constrain mass and evolutionary state. Good fits are obtained for less evolved Type I, I/II, and II sources. Our analysis suggests that there are massive embedded YSOs in N 159B, a maser source, and several ultracompact H II regions. Massive O-type YSOs are found in GMCs N 159-E and N 159-W, which are associated with ionized gas, i.e., where massive stars formed a few Myr ago. The third GMC, N 159-S, has neither O-type YSOs nor evidence of previous massive star formation. This correlation between current and antecedent formation of massive stars suggests that energy feedback is relevant. We present evidence that N 159-W is forming YSOs spontaneously, while collapse in N 159-E may be triggered. Finally, we compare star formation rates determined from YSO counts with those from integrated Hα and 24 μm luminosities and expected from gas surface densities. Detailed dissection of extragalactic GMCs like the one presented here is key to revealing the physics underlying commonly used star formation scaling laws.

  12. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  13. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    International Nuclear Information System (INIS)

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  14. Some observational aspects of compact galactic X-ray sources

    International Nuclear Information System (INIS)

    Heise, J.

    1982-01-01

    This thesis contains the following observations of compact galactic X-ray sources: i) the X-ray experiments onboard the Astronomical Netherlands Satellite ANS, ii) a rocket-borne ultra soft X-ray experiment and iii) the Objective Grating Spectrometer onboard the EINSTEIN observatory. In Chapter I the various types of compact galactic X-ray sources are reviewed and put into the perspective of earlier and following observations. In Chapter II the author presents some of the observations of high luminosity X-ray sources, made with ANS, including the detection of soft X-rays from the compact X-ray binary Hercules X-1 and the ''return to the high state'' of the black hole candidate Cygnus X-1. Chapter III deals with transient X-ray phenomena. Results on low luminosity galactic X-ray sources are collected in Chapter IV. (Auth.)

  15. Mn(II), Zn(II) and VO(II) Schiff

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 113; Issue 3. Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II) Schiff base complexes derived from o-phenylenediamine and acetoacetanilide. N Raman Y Pitchaikani Raja A Kulandaisamy. Inorganic Volume 113 Issue 3 June 2001 pp 183-189 ...

  16. 37 GHz METHANOL MASERS : HORSEMEN OF THE APOCALYPSE FOR THE CLASS II METHANOL MASER PHASE?

    International Nuclear Information System (INIS)

    Ellingsen, S. P.; Breen, S. L.; Sobolev, A. M.; Voronkov, M. A.; Caswell, J. L.; Lo, N.

    2011-01-01

    We report the results of a search for class II methanol masers at 37.7, 38.3, and 38.5 GHz toward a sample of 70 high-mass star formation regions. We primarily searched toward regions known to show emission either from the 107 GHz class II methanol maser transition, or from the 6.035 GHz excited OH transition. We detected maser emission from 13 sources in the 37.7 GHz transition, eight of these being new detections. We detected maser emission from three sources in the 38 GHz transitions, one of which is a new detection. We find that 37.7 GHz methanol masers are only associated with the most luminous 6.7 and 12.2 GHz methanol maser sources, which in turn are hypothesized to be the oldest class II methanol sources. We suggest that the 37.7 GHz methanol masers are associated with a brief evolutionary phase (of 1000-4000 years) prior to the cessation of class II methanol maser activity in the associated high-mass star formation region.

  17. THE EXTENDED He IIλ4686-EMITTING REGION IN IZw 18 UNVEILED: CLUES FOR PECULIAR IONIZING SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Kehrig, C.; Vílchez, J. M.; Pérez-Montero, E.; Iglesias-Páramo, J.; Bayo, F. M. [Instituto de Astrofísica de Andalucía (CSIC), Glorieta de la Astronomía s/n, E-18008 Granada (Spain); Brinchmann, J. [Leiden Observatory, Leiden University, P.O. Box 9513, NL-2300 RA Leiden (Netherlands); Kunth, D.; Durret, F. [Institut d’Astrophysique de Paris, UMR 7095, CNRS and UPMC, 98 bis Bd Arago, F-75014 Paris (France)

    2015-03-10

    New integral field spectroscopy has been obtained for IZw 18, the nearby lowest-metallicity galaxy considered to be our best local analog of systems forming at high redshift (z). Here we report the spatially resolved spectral map of the nebular He ii λ4686 emission in IZw 18, from which we derived for the first time its total He ii-ionizing flux. Nebular He ii emission implies the existence of a hard radiation field. He ii-emitters are observed to be more frequent among high-z galaxies than for local objects. Therefore, investigating the He ii-ionizing source(s) in IZw 18 may reveal the ionization processes at high z. He ii emission in star-forming galaxies has been suggested to be mainly associated with Wolf–Rayet stars (WRs), but WRs cannot satisfactorily explain the He ii-ionization at all times, particularly at the lowest metallicities. Shocks from supernova remnants, or X-ray binaries, have been proposed as additional potential sources of He ii-ionizing photons. Our data indicate that conventional He ii-ionizing sources (WRs, shocks, X-ray binaries) are not sufficient to explain the observed nebular He iiλ4686 emission in IZw 18. We find that the He ii-ionizing radiation expected from models for either low-metallicity super-massive O stars or rotating metal-free stars could account for the He ii-ionization budget measured, while only the latter models could explain the highest values of He iiλ4686/Hβ observed. The presence of such peculiar stars in IZw 18 is suggestive and further investigation in this regard is needed. This letter highlights that some of the clues of the early universe can be found here in our cosmic backyard.

  18. FIRST 'WINGED' AND X-SHAPED RADIO SOURCE CANDIDATES. II. NEW REDSHIFTS

    International Nuclear Information System (INIS)

    Cheung, C. C.; Healey, Stephen E.; Landt, Hermine; Jordan, Andres; Verdoes Kleijn, Gijs

    2009-01-01

    We report optical spectroscopic observations of X-shaped radio sources with the Hobby-Eberly Telescope and Multiple-Mirror Telescope, focused on the sample of candidates from the FIRST survey presented in a previous paper. A total of 27 redshifts were successfully obtained, 21 of which are new, including a newly identified candidate source of this type which is presented here. With these observations, the sample of candidates from the previous paper is over 50% spectroscopically identified. Two new broad emission-lined X-shaped radio sources are revealed, while no emission lines were detected in about one-third of the observed sources; a detailed study of the line properties is deferred to a future paper. Finally, to explore their relation to the Fanaroff-Riley division, the radio luminosities and host galaxy absolute magnitudes of a spectroscopically identified sample of 50 X-shaped radio galaxies are calculated to determine their placement in the Owen-Ledlow plane.

  19. Transient analysis of the new Cold Source at the FRM-II

    International Nuclear Information System (INIS)

    Gutsmiedl, E.; Posselt, H.; Scheuer, A.

    2003-01-01

    The new Cold Source (CNS) at the FRM-II research reactor is completely installed. This paper reports on the results of the transient analysis in the design status for this facility for producing cold neutrons for neutron experiments, the implementation of the results in the design of the mechanical components, the measurements at the cold tests and the comparison with the data of the transient analysis. The important load cases are fixed in the system description and the design data sheet of the CNS. A transient analysis was done with the computer program ESATAN, the nodal configuration was identical with the planned system of the CNS and the boundary conditions were chosen so, that conservative results can be expected. The following transients of the load cases in the piping system behind the inpile part 1) normal storage of D 2 at the hydride storage vessel 2) breakdown of cooling system of the CNS and transfer of D 2 to the buffer tank 3) rapid charge of D 2 to the buffer tank with break of the insulation vacuum and flooding of Neon 4) reloading of the D 2 from the buffer tank to the D 2 hydride storage vessel were calculated. Additionally the temperature distribution for these transients in the connecting flanges of the systems to the inpile part were analysed. The temperature distributions in the flange region were take into account for the strength calculation of the flange construction. The chosen construction shows allowable values and a leak tight flange connection for the load cases. The piping system was designed to the lowest expected temperatures. The load cases in the moderator tank were take into account in the stress analysis and the fatigue analysis of the vacuum vessel and the moderator vessel. The results shows allowable stresses. The results shows that a transient analysis is necessary and helpful for good design of the CNS. (author)

  20. Structural properties of MHC class II ligands, implications for the prediction of MHC class II epitopes.

    Directory of Open Access Journals (Sweden)

    Kasper Winther Jørgensen

    2010-12-01

    Full Text Available Major Histocompatibility class II (MHC-II molecules sample peptides from the extracellular space allowing the immune system to detect the presence of foreign microbes from this compartment. Prediction of MHC class II ligands is complicated by the open binding cleft of the MHC class II molecule, allowing binding of peptides extending out of the binding groove. Furthermore, only a few HLA-DR alleles have been characterized with a sufficient number of peptides (100-200 peptides per allele to derive accurate description of their binding motif. Little work has been performed characterizing structural properties of MHC class II ligands. Here, we perform one such large-scale analysis. A large set of SYFPEITHI MHC class II ligands covering more than 20 different HLA-DR molecules was analyzed in terms of their secondary structure and surface exposure characteristics in the context of the native structure of the corresponding source protein. We demonstrated that MHC class II ligands are significantly more exposed and have significantly more coil content than other peptides in the same protein with similar predicted binding affinity. We next exploited this observation to derive an improved prediction method for MHC class II ligands by integrating prediction of MHC- peptide binding with prediction of surface exposure and protein secondary structure. This combined prediction method was shown to significantly outperform the state-of-the-art MHC class II peptide binding prediction method when used to identify MHC class II ligands. We also tried to integrate N- and O-glycosylation in our prediction methods but this additional information was found not to improve prediction performance. In summary, these findings strongly suggest that local structural properties influence antigen processing and/or the accessibility of peptides to the MHC class II molecule.

  1. Adsorption of Pb(II), Cu(II), Cd(II), Zn(II), Ni(II), Fe(II), and As(V) on bacterially produced metal sulfides.

    Science.gov (United States)

    Jong, Tony; Parry, David L

    2004-07-01

    The adsorption of Pb(II), Cu(II), Cd(II), Zn(II), Ni(II), Fe(II) and As(V) onto bacterially produced metal sulfide (BPMS) material was investigated using a batch equilibrium method. It was found that the sulfide material had adsorptive properties comparable with those of other adsorbents with respect to the specific uptake of a range of metals and, the levels to which dissolved metal concentrations in solution can be reduced. The percentage of adsorption increased with increasing pH and adsorbent dose, but decreased with increasing initial dissolved metal concentration. The pH of the solution was the most important parameter controlling adsorption of Cd(II), Cu(II), Fe(II), Ni(II), Pb(II), Zn(II), and As(V) by BPMS. The adsorption data were successfully modeled using the Langmuir adsorption isotherm. Desorption experiments showed that the reversibility of adsorption was low, suggesting high-affinity adsorption governed by chemisorption. The mechanism of adsorption for the divalent metals was thought to be the formation of strong, inner-sphere complexes involving surface hydroxyl groups. However, the mechanism for the adsorption of As(V) by BPMS appears to be distinct from that of surface hydroxyl exchange. These results have important implications to the management of metal sulfide sludge produced by bacterial sulfate reduction.

  2. The EBR-II Probabilistic Risk Assessment: Results and insights

    International Nuclear Information System (INIS)

    Hill, D.J.; Ragland, W.A.; Roglans, J.

    1993-01-01

    This paper summarizes the results from the recently completed EBR-II Probabilistic Risk Assessment (PRA) and provides an analysis of the source of risk of the operation of EBR-II from both internal and external initiating events. The EBR-II PRA explicitly accounts for the role of reactivity feedbacks in reducing fuel damage. The results show that the expected core damage frequency from internal initiating events at EBR-II is very low, 1. 6 10 -6 yr -1 , even with a wide definition of core damage (essentially that of exceeding Technical Specification limits). The probability of damage, primarily due to liquid metal fires, from externally initiated events (excluding earthquake) is 3.6 10 -6 yr -1 . overall these results are considerably better than results for other research reactors and the nuclear industry in general and stem from three main sources: low likelihood of loss of coolant due to low system pressure and top entry double, vessels; low likelihood of loss of decay heat removal due to reliance on passive means; and low likelihood of power/flow mismatch due to both passive feedbacks and reliability of rod scram capability

  3. Synthesis and spectroscopic studies of biologically active tetraazamacrocyclic complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II

    Directory of Open Access Journals (Sweden)

    Monika Tyagi

    2014-01-01

    Full Text Available Complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II were synthesized with the macrocyclic ligand, i.e., 2,3,9,10-tetraketo-1,4,8,11-tetraazacycoletradecane. The ligand was prepared by the [2 + 2] condensation of diethyloxalate and 1,3-diamino propane and characterized by elemental analysis, mass, IR and 1H NMR spectral studies. All the complexes were characterized by elemental analysis, molar conductance, magnetic susceptibility measurements, IR, electronic and electron paramagnetic resonance spectral studies. The molar conductance measurements of Mn(II, Co(II and Ni(II complexes in DMF correspond to non electrolyte nature, whereas Pd(II and Pt(II complexes are 1:2 electrolyte. On the basis of spectral studies an octahedral geometry has been assigned for Mn(II, Co(II and Ni(II complexes, whereas square planar geometry assigned for Pd(II and Pt(II. In vitro the ligand and its metal complexes were evaluated against plant pathogenic fungi (Fusarium odum, Aspergillus niger and Rhizoctonia bataticola and some compounds found to be more active as commercially available fungicide like Chlorothalonil.

  4. Flare-induced MHD disturbances in the corona--Moreton waves and type II shocks

    International Nuclear Information System (INIS)

    Uchida, Y.

    1972-01-01

    The propagation in the corona of the magnetohydrodynamic (MHD) disturbance possibly emitted at the explosive stage in the initial phase of a flare is considered. The behavior of the MHD fast-mode wavefront, whose source is located at the flare, is calculated by using eiconal-characteristic method in the High Altitude Observatory (HAO) realistic models of coronal magnetic field and density for the days of some particular flare events. It is shown as the result that the peculiar behavior of Moreton' s surface wave and the peculiar appearance in the shape and position of the type II burst sources can be consistently understood by considering the refraction, focussing, and fermation of shocks of MHD fast-mode disturbance in the actual distribution of Alfven velocity in the corona. Based on some comparison of the positions of low-Alfven-velocity regions in the corona with observed positions of type II burst sources, it is proposed that the type II burst sources may be identified with such low-Alfven-velocity regions ''illuminated'' by thus enhanced shocks. (U.S.)

  5. LCLS-II Cryomodules Production at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Arkan, Tug [Fermilab; Grimm, Chuck [Fermilab; Kaluzny, Joshua [Fermilab; Orlov, Yuriy [Fermilab; Peterson, Thomas [Fermilab; Premo, Ken [Fermilab

    2017-05-01

    LCLS-II is an upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac will consist of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab (JLab) will assemble in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW operation. Fermilab and JLab will each assemble and test a prototype 1.3 GHz cryomodule to assess the results of the CW modifications, in advance of 16 and 17 production 1.3 GHz cryomodules, respectively. Fermilab is solely responsible for the 3.9 GHz cryomodules. After the prototype cryomodule tests are complete and lessons learned incorporated, both laboratories will increase their cryomodule production rates to meet the challenging LCLS-II project requirement of approximately one cryomodule per month per laboratory. This paper presents the Fermilab Cryomodule Assembly Facility (CAF) infrastructure for LCLS-II cryomodule production, the Fermilab prototype 1.3 GHz CW cryomodule (pCM) assembly and readiness for production assembly.

  6. Source rock

    Directory of Open Access Journals (Sweden)

    Abubakr F. Makky

    2014-03-01

    Full Text Available West Beni Suef Concession is located at the western part of Beni Suef Basin which is a relatively under-explored basin and lies about 150 km south of Cairo. The major goal of this study is to evaluate the source rock by using different techniques as Rock-Eval pyrolysis, Vitrinite reflectance (%Ro, and well log data of some Cretaceous sequences including Abu Roash (E, F and G members, Kharita and Betty formations. The BasinMod 1D program is used in this study to construct the burial history and calculate the levels of thermal maturity of the Fayoum-1X well based on calibration of measured %Ro and Tmax against calculated %Ro model. The calculated Total Organic Carbon (TOC content from well log data compared with the measured TOC from the Rock-Eval pyrolysis in Fayoum-1X well is shown to match against the shale source rock but gives high values against the limestone source rock. For that, a new model is derived from well log data to calculate accurately the TOC content against the limestone source rock in the study area. The organic matter existing in Abu Roash (F member is fair to excellent and capable of generating a significant amount of hydrocarbons (oil prone produced from (mixed type I/II kerogen. The generation potential of kerogen in Abu Roash (E and G members and Betty formations is ranging from poor to fair, and generating hydrocarbons of oil and gas prone (mixed type II/III kerogen. Eventually, kerogen (type III of Kharita Formation has poor to very good generation potential and mainly produces gas. Thermal maturation of the measured %Ro, calculated %Ro model, Tmax and Production index (PI indicates that Abu Roash (F member exciting in the onset of oil generation, whereas Abu Roash (E and G members, Kharita and Betty formations entered the peak of oil generation.

  7. RTNS-II irradiations and operations

    International Nuclear Information System (INIS)

    Logan, C.M.; Heikkinen, D.W.

    1982-01-01

    The objectives of this work are operation of RTNS-II (a 14-MeV neutron source facility), machine development, and support of the experimental program that utilizes this facility. Experimenter services include dosimetry handling, scheduling, coordination, and reporting. RTNS-II is dedicated to materials research for the fusion power program. Its primary use is to aid in the development of models of high-energy neutron effects. Such models are needed in interpreting and projecting to the fusion environment engineering data obtained in other neutron spectra. Irradiations were performed for a total of twenty-nine different experimenters during this quarter. A JOEL 200 CX TEM and other post-irradiation test equipment have been installed

  8. Pressurized helium II-cooled magnet test facility

    International Nuclear Information System (INIS)

    Warren, R.P.; Lambertson, G.R.; Gilbert, W.S.; Meuser, R.B.; Caspi, S.; Schafer, R.V.

    1980-06-01

    A facility for testing superconducting magnets in a pressurized bath of helium II has been constructed and operated. The cryostat accepts magnets up to 0.32 m diameter and 1.32 m length with current to 3000 A. In initial tests, the volume of helium II surrounding the superconducting magnet was 90 liters. Minimum temperature reached was 1.7 K at which point the pumping system was throttled to maintain steady temperature. Helium II reservoir temperatures were easily controlled as long as the temperature upstream of the JT valve remained above T lambda; at lower temperatures control became difficult. Positive control of the temperature difference between the liquid and cold sink by means of an internal heat source appears necessary to avoid this problem. The epoxy-sealed vessel closures, with which we have had considerable experience with normal helium vacuum, also worked well in the helium II/vacuum environment

  9. IRAS IDENTIFICATION OF PRE-MAIN-SEQUENCE STARS IN THE CHAMELEON-II ASSOCIATION

    NARCIS (Netherlands)

    PRUSTI, T; WHITTET, DCB; ASSENDORP, R; WESSELIUS, PR

    We report the results of a search for new pre-main sequence candidates in the Chamaeleon II dark cloud based on three IRAS catalogues (the Point Source Catalog, the Serendipitous Survey Catalog and the Faint Source Survey). A total of 30 sources were selected. Twelve of these display IRAS colours

  10. NSLS-II booster timing system

    International Nuclear Information System (INIS)

    Cheblakov, P.; Karnaev, S.; De Long, J.

    2012-01-01

    NSLS-II light source includes the main storage ring with beam lines and injection part consisting of 200 MeV linac, a full-energy 3 GeV booster synchrotron and two transport lines. The booster timing system is a part of NSLS-II timing system which uses hardware from MicroResearch Finland: Event Generator (EVG) and Event Receivers (EVRs). The booster timing is based on the events coming from NSLS-II EVG: 'Pre-Injection', 'Injection', 'Pre-Extraction', 'Extraction'. These events are referenced to the selected RF bucket of the storage ring and correspond to the first RF bucket of the booster. EVRs provide triggers both for the injection and the extraction pulse devices. EVRs also provide the timing of booster cycle operation and generation of events for cycle-to-cycle updates of pulsed and ramping parameters, and synchronization of the booster beam instrumentation devices. This paper describes the final design of the booster timing system. The timing system functional diagrams and block diagram are presented. (authors)

  11. Test of GERDA Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Gusev, Konstantin [Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard; Wagner, Victoria [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    The GERDA experiment searches for the lepton number violating neutrinoless double beta decay (0νββ) of {sup 76}Ge. The experiment uses HPGe detectors enriched in {sup 76}Ge as source and detection material. In GERDA Phase I five BEGe detectors were operated successfully. These detectors are distinguished for improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. In Phase II additional 25 BEGe detectors will be installed. New electronics and radio-pure low-mass holders were specially designed for Phase II. Prior to the installation in GERDA all BEGe detectors are tested in their final assembly in the LNGS underground laboratory. This talk presents the mechanics and performance of the GERDA Phase II detector assembly.

  12. Radio weak lensing shear measurement in the visibility domain - II. Source extraction

    Science.gov (United States)

    Rivi, M.; Miller, L.

    2018-05-01

    This paper extends the method introduced in Rivi et al. (2016b) to measure galaxy ellipticities in the visibility domain for radio weak lensing surveys. In that paper, we focused on the development and testing of the method for the simple case of individual galaxies located at the phase centre, and proposed to extend it to the realistic case of many sources in the field of view by isolating visibilities of each source with a faceting technique. In this second paper, we present a detailed algorithm for source extraction in the visibility domain and show its effectiveness as a function of the source number density by running simulations of SKA1-MID observations in the band 950-1150 MHz and comparing original and measured values of galaxies' ellipticities. Shear measurements from a realistic population of 104 galaxies randomly located in a field of view of 1 \\deg ^2 (i.e. the source density expected for the current radio weak lensing survey proposal with SKA1) are also performed. At SNR ≥ 10, the multiplicative bias is only a factor 1.5 worse than what found when analysing individual sources, and is still comparable to the bias values reported for similar measurement methods at optical wavelengths. The additive bias is unchanged from the case of individual sources, but it is significantly larger than typically found in optical surveys. This bias depends on the shape of the uv coverage and we suggest that a uv-plane weighting scheme to produce a more isotropic shape could reduce and control additive bias.

  13. Expansion design for a Laboratory of Radioactive Sources Handling type II, class B

    International Nuclear Information System (INIS)

    Sanchez S, P. S.

    2014-01-01

    This work presents the expansion design of the Radioactive Wastes Research Laboratory (RWRL) installation authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico) as type II class C, to manage 40 different radionuclides, approximately. The RWRL has 4 areas at the present time: a laboratory of instrumental analysis, one of radioactive material processes, other of counting and a chemical reagents stock, which is not integrated to the operation license of the RWRL. With the purpose of expanding the operation license of the RWRL to an installation type II class B, to manage until 370 MBq of high radio toxicity radionuclides, is presented in this work an expansion proposal of the RWRL. The expansion proposal is based in: (1) the Mexican Nuclear Standard NOM-027-Nucl-1996 for installations type II class B, (2) the current distribution of water, light, electricity, extraction, gas, air and vacuum services of RWRL, and (3) the available areas inside the building that the RWRL occupies. The proposal contemplates the creation of additional new areas for RWRL: 3 laboratories, 2 dressing rooms, 2 bathrooms and 2 warehouses, one for radioactive materials and another for reagents chemical radiologically inactive. Architectural, electric, hydraulic, extraction and gas planes corresponding to the expansion of RWRL were realized. Inside the proposal the budget required to carry out the mentioned expansion is also presented. (Author)

  14. Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

    International Nuclear Information System (INIS)

    Joo, Youngdo; Yu, Inha; Park, Insoo; Chun, Myunghwan; Lee, Byung-Joon; Hwang, Ilmoon; Ha, Taekyun; Shin, Seunghwan; Sohn, Younguk

    2014-01-01

    After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out

  15. The Data Release of the Sloan Digital Sky Survey-II Supernova Survey

    DEFF Research Database (Denmark)

    Sako, Masao; Bassett, Bruce; C. Becker, Andrew

    2014-01-01

    This paper describes the data release of the Sloan Digital Sky Survey-II (SDSS-II) Supernova Survey conducted between 2005 and 2007. Light curves, spectra, classifications, and ancillary data are presented for 10,258 variable and transient sources discovered through repeat ugriz imaging of SDSS S...

  16. Thermodynamics II essentials

    CERN Document Server

    REA, The Editors of

    2013-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Thermodynamics II includes review of thermodynamic relations, power and refrigeration cycles, mixtures and solutions, chemical reactions, chemical equilibrium, and flow through nozzl

  17. Electronics II essentials

    CERN Document Server

    REA, The Editors of

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Electronics II covers operational amplifiers, feedback and frequency compensation of OP amps, multivibrators, logic gates and families, Boolean algebra, registers, counters, arithmet

  18. Statistics II essentials

    CERN Document Server

    Milewski, Emil G

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Statistics II discusses sampling theory, statistical inference, independent and dependent variables, correlation theory, experimental design, count data, chi-square test, and time se

  19. Effect of Cu(II), Cd(II) and Zn(II) on Pb(II) biosorption by algae Gelidium-derived materials.

    Science.gov (United States)

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2008-06-15

    Biosorption of Pb(II), Cu(II), Cd(II) and Zn(II) from binary metal solutions onto the algae Gelidium sesquipedale, an algal industrial waste and a waste-based composite material was investigated at pH 5.3, in a batch system. Binary Pb(II)/Cu(II), Pb(II)/Cd(II) and Pb(II)/Zn(II) solutions have been tested. For the same equilibrium concentrations of both metal ions (1 mmol l(-1)), approximately 66, 85 and 86% of the total uptake capacity of the biosorbents is taken by lead ions in the systems Pb(II)/Cu(II), Pb(II)/Cd(II) and Pb(II)/Zn(II), respectively. Two-metal results were fitted to a discrete and a continuous model, showing the inhibition of the primary metal biosorption by the co-cation. The model parameters suggest that Cd(II) and Zn(II) have the same decreasing effect on the Pb(II) uptake capacity. The uptake of Pb(II) was highly sensitive to the presence of Cu(II). From the discrete model it was possible to obtain the Langmuir affinity constant for Pb(II) biosorption. The presence of the co-cations decreases the apparent affinity of Pb(II). The experimental results were successfully fitted by the continuous model, at different pH values, for each biosorbent. The following sequence for the equilibrium affinity constants was found: Pb>Cu>Cd approximately Zn.

  20. Observations of the Galaxy NGC 3077 in the Narrow-Band [S II] and Hα Filters

    Directory of Open Access Journals (Sweden)

    Andjelić M.

    2011-09-01

    Full Text Available We present observations of the H I tidal arm near a dwarf galaxy NGC 3077 (member of the M81 galaxy group in the narrow-band [S II] and Hα filters. Observations were carried out in 2011 March with the 2 m RCC telescope at the NAO Rozhen, Bulgaria. Our search for possible supernova remnant candidates (identified as sources with enhanced [S II] emission relative to their Hα emission in this region yielded no sources of this kind. Nevertheless, we found a number of objects with significant Hα emission that probably represent uncatalogued, low brightness H II regions.

  1. Multisource inverse-geometry CT. Part II. X-ray source design and prototype

    Energy Technology Data Exchange (ETDEWEB)

    Neculaes, V. Bogdan, E-mail: neculaes@ge.com; Caiafa, Antonio; Cao, Yang; De Man, Bruno; Edic, Peter M.; Frutschy, Kristopher; Gunturi, Satish; Inzinna, Lou; Reynolds, Joseph; Vermilyea, Mark; Wagner, David; Zhang, Xi; Zou, Yun [GE Global Research, Niskayuna, New York 12309 (United States); Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Lounsberry, Brian [Healthcare Science Technology, GE Healthcare, West Milwaukee, Wisconsin 53219 (United States)

    2016-08-15

    Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent

  2. Peripheral Codes in ASTRA for the TJ-II; Programas Perifericos de ASTRA para el TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Bruna, D.; Reynolds, J. M.; Cappa, A.; Martinell, J.; Garcia, J.; Gutierrez-Tapia, C.

    2010-05-01

    The study of data from the TJ-II device is often done with transport calculations based on the ASTRA transport system. However, complicated independent codes are used to obtain fundamental ingredients in these calculations, such as the particle and/or energy sources. These codes are accessible from ASTRA through the procedures explained in this report. (Author) 37 refs.

  3. Latest experiences and future plans on NSLS-II insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, T.; Hidaka, Y.; Kitegi, C.; Hidas, D.; Musardo, M.; Harder, D. A.; Rank, J.; Cappadoro, P.; Fernandes, H.; Corwin, T. [Energy Sciences Directorate, Brookhaven National Laboratory, Upton, NY 11973, U.S.A (United States)

    2016-07-27

    National Synchrotron Light Source-II (NSLS-II) is the latest storage ring of 3 GeV energy at the Brookhaven National Laboratory (BNL). The horizontal emittance of the electron beam with the currently installed six damping wigglers is 0.9 nm.rad, which could be further reduced to 0.5 nm.rad with more insertion devices (IDs). With only one RF cavity the beam current is restricted to 200 mA. Five hundred mA operation is envisaged for next year with an addition of the second cavity. Six (plus two branches) beamlines have been commissioned in the initial phase of the project. In July 2015, three NIH funded beamlines called “Advanced Beamlines for Biological Investigations with X-rays” (ABBIX) will be added for operation. This paper describes the experiences of ID development, installation, and commissioning for the NSLS-II project as well as our future plans to improve the performance of the facility in terms of source development.

  4. A CLUSTER OF COMPACT RADIO SOURCES IN W40

    International Nuclear Information System (INIS)

    RodrIguez, Luis F.; Rodney, Steven A.; Reipurth, Bo

    2010-01-01

    We present deep 3.6 cm radio continuum observations of the H II region W40 obtained using the Very Large Array (VLA) in its A and B configurations. We detect a total of 20 compact radio sources in a region of 4' x 4', with 11 of them concentrated in a band with 30'' of extent. We also present JHK photometry of the W40 cluster taken with the QUIRC instrument on the University of Hawaii 2.2 m telescope. These data reveal that 15 of the 20 VLA sources have infrared counterparts, and 10 show radio variability with periods less than 20 days. Based on these combined radio and IR data, we propose that eight of the radio sources are candidate ultracompact H II regions, seven are likely to be young stellar objects, and two may be shocked interstellar gas.

  5. A High Reliability Frequency Stabilized Semiconductor Laser Source, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, high reliability MOPA sources are needed for high performance LIDARs in NASA for, wind speed measurement, surface topography and earth...

  6. PEP-II prototype klystron

    International Nuclear Information System (INIS)

    Fowkes, W.R.; Caryotakis, G.; Lee, T.G.; Pearson, C.; Wright, E.L.

    1993-04-01

    A 540-kW continuous-wave (cw) klystron operating at 476 MHz was developed for use as a power source for testing PEP-II rf accelerating cavities and rf windows. It also serves as a prototype for a 1.2 MW cw klystron presently being developed as a potential rf source for asymmetric colliding ring use. The design incorporates the concepts and many of the parts used in the original 353 MHz PEP klystron developed sixteen years ago. The superior computer simulation codes available today result in improved performance with the cavity frequencies, drift lengths, and output circuit optimized for the higher frequency.The design and operating results of this tube are described with particular emphasis on the factors which affect efficiency and stability

  7. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  8. SELF-CONSISTENT EVOLUTION OF GAS AND COSMIC RAYS IN CYGNUS A AND SIMILAR FR II CLASSICAL DOUBLE RADIO SOURCES

    International Nuclear Information System (INIS)

    Mathews, William G.; Guo Fulai

    2010-01-01

    In Cygnus A and other classical FR II double radio sources, powerful opposing jets from the cores of halo-centered galaxies drive out into the surrounding cluster gas, forming hotspots of shocked and compressed cluster gas at the jet extremities. The moving hotspots are sandwiched between two shocks. An inner-facing shock receives momentum and cosmic rays from the jet and creates additional cosmic rays that form a radio lobe elongated along the jet axis. An outer-facing bow shock moves directly into the undisturbed group or cluster gas, creating a cocoon of shocked gas enclosing the radio lobe. We describe computations that follow the self-consistent dynamical evolution of the shocked cluster gas and the relativistic synchrotron-emitting gas inside the lobes. Relativistic and non-relativistic components exchange momentum by interacting with small magnetic fields having dynamically negligible energy densities. The evolution of Cygnus A is governed almost entirely by cosmic ray energy flowing from the hotspots. Mass flowing into hotspots from the jets is assumed to be small, greatly reducing the mass of gas flowing back along the jet, common in previous calculations, that would disrupt the spatial segregation of synchrotron-loss ages observed inside FR II radio lobes. We compute the evolution of the cocoon when the velocity and cosmic ray luminosity of the hotspots are constant and when they vary with time. If cosmic rays mix with cluster gas in hotspots before flowing into the radio lobe, the thermal gas is heated to mildly relativistic temperatures, producing an unobserved pressure inside the lobe.

  9. Physicochemical properties of 3,4,5-trimethoxybenzoates of Mn(II, Co(II, Ni(II and Zn(II

    Directory of Open Access Journals (Sweden)

    W. FERENC

    2005-09-01

    Full Text Available The complexes of Mn(II, Co(II, Ni(II, Cu(II and Zn(II with 3,4,5-trimethoxybenzoic acid anion of the formula: M(C10H11O52·nH2O, where n = 6 for Ni(II, n = 1 for Mn(II, Co(II, Cu(II, and n = 0 for Zn, have been synthesized and characterized by elemental analysis, IR spectroscopy, X–ray diffraction measurements, thermogravimetry and magnetic studies. They are crystalline compounds characterized by various symmetry. They decompose in various ways when heated in air to 1273 K. At first, they dehydrate in one step and form anhydrous salts. The final products of decomposition are oxides of the respective metals (Mn2O3, Co3O4, NiO, CuO, ZnO. The solubilities of the analysed complexes in water at 293 K are in the orders of 10-2 – 10-4 mol dm-3. The magnetic susceptibilities of the Mn(II, Co(II, Ni(II and Cu(II complexes were measured over the range of 76–303 K and the magnetic moments were calculated. The results show that the 3,4,5-trimethoxybenzoates of Mn(II, Co(II and Ni(II are high-spin complexes but that of Cu(II forms a dimer [Cu2(C10H11O54(H2O2]. The carboxylate groups bind as monodentate or bidentate chelating or bridging ligands.

  10. Water vapor emission from H II regions and infrared stars

    International Nuclear Information System (INIS)

    Cato, B.T.; Ronnang, B.O.; Rydbeck, O.E.H.; Lewin, P.T.; Yngvesson, K.S.; Cardiasmenos, A.G.; Shanley, J.F.

    1976-01-01

    The spatial structure of water vapor microwave line emission has been investigated with moderate angular resolution in several well-known H II regions. New H 2 O sources have been with infrared (1R) sources. One of these sources, IRC: 20411, has been investigated at optical wavelengths. It is found to be of spectral class M3-M5 and by indirect evidence the luminosity class is preliminarily determined to Ib. The distance is estimated to be approx.2 kpc, and the star must be in front of the dust complex which obscures W28 A2. In NGC 7538 new high-velocity features have been discovered. Two new weak water vapor masers, G30.1: 0.7 and G32.8: 0.3, have been detected in a search among eight class II OH/IR sources. H 2 O emission coinciding with the low-velocity OH features of VY Canis Majoris has also been detected. A search for local thermodynamic equilibrium (LTE) water-vapor line emission in molecular clouds associated with H II regions is also reported. No line was detected with the utilized sensitivity. The physical implications of this are discussed and an upper limit of the H 2 O column density has been estimated. Gaussian analysis of the strong, narrow feature in the spectrum of ON 1 indicates a possible presence of two hyperfine components, viz., F→F'=7→6 and 6→5

  11. Neutral beam source commercialization study. Final report

    International Nuclear Information System (INIS)

    King, H.J.

    1980-06-01

    The basic tasks of this Phase II project were to: generate a set of design drawings suitable for quantity production of sources of this design; fabricate a functional neutral beam source incorporating as many of the proposed design changes as proved feasible; and document the procedures and findings developed during the contract. These tasks have been accomplished and represent a demonstrated milestone in the industrialization of this complete device

  12. Small Galactic H II regions. II. The molecular clouds and star formation

    International Nuclear Information System (INIS)

    Hunter, D.A.; Thronson, H.A. Jr.; Wilton, C.

    1990-01-01

    CO maps of molecular clouds associated with 11 small Galactic H II regions are presented and compared with IR images obtained by IRAS. The molecular masses of the clouds are computed and compared with the masses of the stellar content. The mapped clouds have masses of 1000-60,000 solar and are typical of the more numerous, smaller Galactic molecular clouds. All of the clouds have recently made massive OB stars, and many have complex spatial and kinematic structures. The coincidence of IRAS sources and CO peaks suggests that many of the clouds have sites of star formation other than the optically visible H II region. Star-formation efficiencies are uncertain, with values for the clouds ranging from 0.02 to 0.6 with an average value of 0.2. There is no trend of the upper stellar mass limit with Galactic radius and with molecular cloud mass. 53 refs

  13. Synthesis and spectral studies of manganese(II), cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and mercury(II) complexes of 4-oxo-4H-1-benzopyran-3-carboxaldehyde hydrazone derivatives

    International Nuclear Information System (INIS)

    Nawar, N.; Khattab, M.A.; Bekheit, M.M.; El-Kaddah, A.H.

    1996-01-01

    A few complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) with 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-chlorobenzylhydrazone) (BCBH) and 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-methylbenzylhydrazone) (BMBH) have been synthesised and characterized by elemental analysis, molar conductivities, magnetic measurements and infrared (IR) and visible spectral studies. The IR spectra show that BCBH and BMBH behave as bidentate ligands either in the keto or enol form. (author). 24 refs., 2 tabs

  14. Synthesis, Characterization, and Biological Activity of Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II Complexes of N-Thiophenoyl-N′-Phenylthiocarbohydrazide

    Directory of Open Access Journals (Sweden)

    M. Yadav

    2013-01-01

    Full Text Available Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II complex of N-thiophenoyl -N′-phenylthiocarbohydrazide (H2 TPTH have been synthesized and characterized by elemental analysis, magnetic susceptibility measurements, infrared, NMR, electronic, and ESR spectral studies. The complexes were found to have compositions [Mn(H TPTH2], [Co(TPTH (H2O2], [Ni(TPTH (H2O2], [Cu(TPTH], [Zn(H TPTH], [Cd(H TPTH2], and [Fe(H TPTH2(EtOH]. The magnetic and electronic spectral studies suggest square planar geometry for [Cu(TPTH], tetrahedral geometry for [Zn(TPTH] and [Cd(H TPTH2], and octahedral geometry for rest of the complexes. The infrared spectral studies of the 1 : 1 deprotonated complexes suggest bonding through enolic oxygen, thiolato sulfur, and both the hydrazinic nitrogens. Thus, H2TPTH acts as a binegative tetradentate ligand. H2 TPTH and its metal complexes have been screened against several bacteria and fungi.

  15. Nature of the Diffuse Source and Its Central Point-like Source in SNR 0509–67.5

    Energy Technology Data Exchange (ETDEWEB)

    Litke, Katrina C.; Chu, You-Hua; Holmes, Abigail; Santucci, Robert; Blindauer, Terrence; Gruendl, Robert A.; Ricker, Paul M. [Astronomy Department, University of Illinois, 1002 W. Green Street, Urbana, IL 61801 (United States); Li, Chuan-Jui [Academia Sinica Institute of Astronomy and Astrophysics, P.O. Box 23-141, Taipei 10617, Taiwan, R.O.C. (China); Pan, Kuo-Chuan [Departement Physik, Universität Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Weisz, Daniel R., E-mail: kclitke@email.arizona.edu [Department of Astronomy, University of California, 501 Cambell Hall #3411, Berkeley, CA 94720-3411 (United States)

    2017-03-10

    We examine a diffuse emission region near the center of SNR 0509−67.5 to determine its nature. Within this diffuse region we observe a point-like source that is bright in the near-IR, but is not visible in the B and V bands. We consider an emission line observed at 6766 Å and the possibilities that it is Ly α , H α , and [O ii] λ 3727. We examine the spectral energy distribution (SED) of the source, comprised of Hubble Space Telescope B , V , I , J , and H bands in addition to Spitzer /IRAC 3.6, 4.5, 5.8, and 8 μ m bands. The peak of the SED is consistent with a background galaxy at z ≈ 0.8 ± 0.2 and a possible Balmer jump places the galaxy at z ≈ 0.9 ± 0.3. These SED considerations support the emission line’s identification as [O ii] λ 3727. We conclude that the diffuse source in SNR 0509−67.5 is a background galaxy at z ≈ 0.82. Furthermore, we identify the point-like source superposed near the center of the galaxy as its central bulge. Finally, we find no evidence for a surviving companion star, indicating a double-degenerate origin for SNR 0509−67.5.

  16. Nature of the Diffuse Source and Its Central Point-like Source in SNR 0509–67.5

    International Nuclear Information System (INIS)

    Litke, Katrina C.; Chu, You-Hua; Holmes, Abigail; Santucci, Robert; Blindauer, Terrence; Gruendl, Robert A.; Ricker, Paul M.; Li, Chuan-Jui; Pan, Kuo-Chuan; Weisz, Daniel R.

    2017-01-01

    We examine a diffuse emission region near the center of SNR 0509−67.5 to determine its nature. Within this diffuse region we observe a point-like source that is bright in the near-IR, but is not visible in the B and V bands. We consider an emission line observed at 6766 Å and the possibilities that it is Ly α , H α , and [O ii] λ 3727. We examine the spectral energy distribution (SED) of the source, comprised of Hubble Space Telescope B , V , I , J , and H bands in addition to Spitzer /IRAC 3.6, 4.5, 5.8, and 8 μ m bands. The peak of the SED is consistent with a background galaxy at z ≈ 0.8 ± 0.2 and a possible Balmer jump places the galaxy at z ≈ 0.9 ± 0.3. These SED considerations support the emission line’s identification as [O ii] λ 3727. We conclude that the diffuse source in SNR 0509−67.5 is a background galaxy at z ≈ 0.82. Furthermore, we identify the point-like source superposed near the center of the galaxy as its central bulge. Finally, we find no evidence for a surviving companion star, indicating a double-degenerate origin for SNR 0509−67.5.

  17. The design and characteristics of direct current glow discharge atomic emission source operated with plain and hollow cathodes

    International Nuclear Information System (INIS)

    Qayyum, A.; Mahmood, M.I.

    2008-01-01

    A compact direct current glow discharge atomic emission source has been designed and constructed for analytical applications. This atomic emission source works very efficiently at a low-input electrical power. The design has some features that make it distinct from that of the conventional Grimm glow discharge source. The peculiar cathode design offered greater flexibility on size and shape of the sample. As a result the source can be easily adopted to operate in Plain or Hollow Cathode configuration. I-V and spectroscopic characteristics of the source were compared while operating it with plain and hollow copper cathodes. It was observed that with hollow cathode, the source can be operated at a less input power and generates greater Cu I and Cu II line intensities. Also, the intensity of Cu II line rise faster than Cu I line with argon pressure for both cathodes. But the influence of pressure on Cu II lines was more significant when the source is operated with hollow cathode

  18. Possible use of tannin resins belonging to the luztan family in the Cd (II) sorption of watery sources

    International Nuclear Information System (INIS)

    Melchor, K.; Lima, L.; Luzardo, F. M.; Vargas, L. M.; Santana, J. L.; E.mail: keniamr@ctn.isctn.edu.cu

    2003-01-01

    There are studied the optimum sorption conditions of the Cd (II) in five different natural sorbent variants obtained from the tannin immobilization and re-immobilization in the vegetal bark of the species Ecualiptus saligna and Pinus caribea for being used to remove this metal from waste water. It was determined the sorption balance time of the Cd (II) in every sorbent, as well as, the corresponding sorption isotherms. The breakdown curves were obtained under dynamic conditions for the absorbents, that experienced a higher sorption for the Cd (II), from these curves, it was obtained the dynamic sorption capacity of them for the Cd (II)

  19. Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II binary complexes of l-methionine in 1,2-propanediol-water mixtures

    Directory of Open Access Journals (Sweden)

    M. Padma Latha

    2007-04-01

    Full Text Available Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-methionine in 0.0-60 % v/v 1,2-propanediol-water mixtures maintaining an ionic strength of 0.16 M at 303 K has been studied pH metrically. The active forms of ligand are LH2+, LH and L-. The predominant species detected are ML, MLH, ML2, ML2H, ML2H2 and MLOH. Models containing different numbers of species were refined by using the computer program MINIQUAD 75. The best-fit chemical models were arrived at based on statistical parameters. The trend in variation of complex stability constants with change in the dielectric constant of the medium is explained on the basis of electrostatic and non-electrostatic forces.

  20. Personalisatie in academische bibliotheeksystemen. - II: MyLibrary voorbij

    NARCIS (Netherlands)

    Hunsucker, R.L.

    2005-01-01

    Personalisation in academic library systems - II: Beyond MyLibrary The academic libraries' attempt to 'personalise' tracking down and accessing relevant literature and information sources developed into an undeniably meagre performance. So wrote R.L. Hunsucker in the first part of his contribution

  1. AMINO AND MERCAPTO-SILICA HYBRID FOR Cd(II ADSORPTION IN AQUEOUS SOLUTION

    Directory of Open Access Journals (Sweden)

    Buhani Buhani

    2010-06-01

    Full Text Available Modification of silica gel with 3-aminopropyltrimethoxysilane and 3-mercaptopropyltrimethoxysilane through sol-gel technique producing amino-silica hybrid (HAS and mercapto-silica hybrid (HMS, respectively, has been carried out using tetraethylorthosilicate (TEOS as silica source. The adsorbents were characterized using infrared spectroscopy (IR, and X-ray energy dispersion spectroscopy (EDX. Adsorption of Cd(II individually as well as its binary mixture with Ni(II, Cu(II, and Zn(II in solution was performed in a batch system. Adsorption capacities of Cd(II ion on adsorbent of silica gel (SG, HAS, and HMS are 86.7, 256.4 and 319.5 μmol/g with the adsorption energies are 24.60, 22.61 and 23.15 kJ/mol, respectively. Selectivity coefficient (α of Cd(II ion toward combination of Cd(II/Ni(II, Cd(II/Cu(II, and Cd(II/Zn(II ions on HAS adsorbent is relatively smaller than those on HMS adsorbent which has α > 1.   Keywords: adsorption, amino-silica hybrid, mercapto-silica

  2. Resveratrol: A novel type of topoisomerase II inhibitor.

    Science.gov (United States)

    Lee, Joyce H; Wendorff, Timothy J; Berger, James M

    2017-12-22

    Resveratrol, a polyphenol found in various plant sources, has gained attention as a possible agent responsible for the purported health benefits of certain foods, such as red wine. Despite annual multi-million dollar market sales as a nutriceutical, there is little consensus about the physiological roles of resveratrol. One suggested molecular target of resveratrol is eukaryotic topoisomerase II (topo II), an enzyme essential for chromosome segregation and DNA supercoiling homeostasis. Interestingly, resveratrol is chemically similar to ICRF-187, a clinically approved chemotherapeutic that stabilizes an ATP-dependent dimerization interface in topo II to block enzyme activity. Based on this similarity, we hypothesized that resveratrol may antagonize topo II by a similar mechanism. Using a variety of biochemical assays, we find that resveratrol indeed acts through the ICRF-187 binding locus, but that it inhibits topo II by preventing ATPase domain dimerization rather than stabilizing it. This work presents the first comprehensive analysis of the biochemical effects of both ICRF-187 and resveratrol on the human isoforms of topo II, and reveals a new mode for the allosteric regulation of topo II through modulation of ATPase status. Natural polyphenols related to resveratrol that have been shown to impact topo II function may operate in a similar manner. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  3. 10C survey of radio sources at 15.7 GHz - II. First results

    Science.gov (United States)

    AMI Consortium; Davies, Mathhew L.; Franzen, Thomas M. O.; Waldram, Elizabeth M.; Grainge, Keith J. B.; Hobson, Michael P.; Hurley-Walker, Natasha; Lasenby, Anthony; Olamaie, Malak; Pooley, Guy G.; Riley, Julia M.; Rodríguez-Gonzálvez, Carmen; Saunders, Richard D. E.; Scaife, Anna M. M.; Schammel, Michel P.; Scott, Paul F.; Shimwell, Timothy W.; Titterington, David J.; Zwart, Jonathan T. L.

    2011-08-01

    In a previous paper (Paper I), the observational, mapping and source-extraction techniques used for the Tenth Cambridge (10C) Survey of Radio Sources were described. Here, the first results from the survey, carried out using the Arcminute Microkelvin Imager Large Array (LA) at an observing frequency of 15.7 GHz, are presented. The survey fields cover an area of ≈27 deg2 to a flux-density completeness of 1 mJy. Results for some deeper areas, covering ≈12 deg2, wholly contained within the total areas and complete to 0.5 mJy, are also presented. The completeness for both areas is estimated to be at least 93 per cent. The 10C survey is the deepest radio survey of any significant extent (≳0.2 deg2) above 1.4 GHz. The 10C source catalogue contains 1897 entries and is available online. The source catalogue has been combined with that of the Ninth Cambridge Survey to calculate the 15.7-GHz source counts. A broken power law is found to provide a good parametrization of the differential count between 0.5 mJy and 1 Jy. The measured source count has been compared with that predicted by de Zotti et al. - the model is found to display good agreement with the data at the highest flux densities. However, over the entire flux-density range of the measured count (0.5 mJy to 1 Jy), the model is found to underpredict the integrated count by ≈30 per cent. Entries from the source catalogue have been matched with those contained in the catalogues of the NRAO VLA Sky Survey and the Faint Images of the Radio Sky at Twenty-cm survey (both of which have observing frequencies of 1.4 GHz). This matching provides evidence for a shift in the typical 1.4-GHz spectral index to 15.7-GHz spectral index of the 15.7-GHz-selected source population with decreasing flux density towards sub-mJy levels - the spectra tend to become less steep. Automated methods for detecting extended sources, developed in Paper I, have been applied to the data; ≈5 per cent of the sources are found to be extended

  4. Insulin-like growth factor II messenger ribonucleic acids are synthesized in the choroid plexus of the rat brain

    International Nuclear Information System (INIS)

    Hynes, M.A.; Brooks, P.J.; Van Wyk, J.J.; Lund, P.K.

    1988-01-01

    Previous studies demonstrating the presence of immunoreactive insulin-like growth factors (IGFs) and their receptors in the brain suggest a role of the IGFs in the central nervous system. IGF-II has been implicated as the predominant IGF in brain of mature animals based on studies of immunoreactive peptide and of IGF-II mRNAs. To obtain information about the sites of synthesis of IGF-II in adult rat brain, a 32 P-labeled 31 base long synthetic oligodeoxyribonucleotide complementary in sequence to trailer peptide coding sequences in rat IGF-II mRNA (IGF-II 31 mer) was hybridized with coronal sections of fixed rat brain. The IGF-II 31 mer showed specific hybridization with the choroid plexus throughout rat brain, whereas in other brain regions, structures or cells, hybridization was not discernibly above background. These findings suggest that the choroid plexus is a primary site of synthesis of IGF-II, a probable source of IGF-II in cerebrospinal fluid, and a potential source of IGF-II for actions on target cells within the adult rat brain

  5. Far-infrared observations of M17: The interaction of an H II region with a molecular cloud

    International Nuclear Information System (INIS)

    Gatley, I.; Becklin, E.E.; Sellgren, K.; Werner, M.W.

    1979-01-01

    The central 15' of the M17 H II region--molecular cloud complex has been mapped with 1' resolution simultaneously at 30, 50, and 100 μm. The data suggest that the bulk of the luminosity radiated in the far-infrared is supplied by the exciting stars of the H II region; the far-infrared radiation is thermal emission from dust grains located chiefly outside the ionized gas. Large-scale systematic gradients in both the temperature and the column density of the dust are seen across the source. The appearance of the source in the far-infrared reflects the markedly nonuniform distribution of matter around the exciting stars; the H II region is bounded by the molecular cloud to the southwest. The core of the molecular cloud is heated primarily by infrared radiation from dust within and adjacent to the H II region; no evidence is seen for substantial luminosity sources embedded within the molecular cloud

  6. “Materials for the Dictionary of the Old Russian Language in the Written Records” by I.I. Sreznevskiy As the Source of Diachronic Research of the Substantive Word-Formation

    Directory of Open Access Journals (Sweden)

    Anastasiya Yuryevna Vekolova

    2015-12-01

    Full Text Available The article presents the results of the historical research in historical aspect on word-formation based on «Materials for the dictionary of the old Russian language in the written records» by I.I. Sreznevskiy that is characterized as the most important source of lexicographical material for the diachronic research. The dictionary is the only completed lexicographical source that reflects the language in the XI-XVII cent. It includes samples of the old Slavic and the old Russian written monuments, thus demonstrating lexis from the variety of sources. Its entries represent data on lexical, in particular word building system of the Old Russian language. The significance of the «Materials for the dictionary of the old Russian language in the written records» by I.I. Sreznevskiy for the diachronic research of the substantive wordformation is proved with the system of the old Russian substantive derivatives with evaluative suffixes that was allocated in the research. Productive modification formants are revealed, their morphological characteristics are considered. Special attention is concentrated on the analysis of the suffixal frequency. On the basis of the dictionary data connotation of affixes is characterized, options of suffixes are given. It is noted that these morphemes have a positive or negative assessment. The compiler of this dictionary pays attention to the connotation. The suggested indication of the word allows defining the boundaries of suffixes. Examples of the derivatives with evaluative affixes in context are given. It is emphasized that the presence of the usage helps to systematic comprehension of the material.

  7. Language identification using excitation source features

    CERN Document Server

    Rao, K Sreenivasa

    2015-01-01

    This book discusses the contribution of excitation source information in discriminating language. The authors focus on the excitation source component of speech for enhancement of language identification (LID) performance. Language specific features are extracted using two different modes: (i) Implicit processing of linear prediction (LP) residual and (ii) Explicit parameterization of linear prediction residual. The book discusses how in implicit processing approach, excitation source features are derived from LP residual, Hilbert envelope (magnitude) of LP residual and Phase of LP residual; and in explicit parameterization approach, LP residual signal is processed in spectral domain to extract the relevant language specific features. The authors further extract source features from these modes, which are combined for enhancing the performance of LID systems. The proposed excitation source features are also investigated for LID in background noisy environments. Each chapter of this book provides the motivatio...

  8. HERMES II experimenters' manual (revised)

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The HERMES II is a high-intensity laboratory photon source for gamma-ray radiation effects experiments as well as a high-energy pulsed electron beam generator for a variety of potential applications. The purpose of this manual is to serve as a basic source of information for prospective users of HERMES. Included is a brief discussion of the design and operation of the accelerator system as well as a summary of environmental data for x-ray operation and output characteristics for electron beam modes. The manual also contains a description of the HERMES experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  9. Transport phenomena II essentials

    CERN Document Server

    REA, The Editors of

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Transport Phenomena II covers forced convention, temperature distribution, free convection, diffusitivity and the mechanism of mass transfer, convective mass transfer, concentration

  10. Heat transfer II essentials

    CERN Document Server

    REA, The Editors of

    1988-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Heat Transfer II reviews correlations for forced convection, free convection, heat exchangers, radiation heat transfer, and boiling and condensation.

  11. Algebra & trigonometry II essentials

    CERN Document Server

    REA, Editors of

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Algebra & Trigonometry II includes logarithms, sequences and series, permutations, combinations and probability, vectors, matrices, determinants and systems of equations, mathematica

  12. Numerical analysis II essentials

    CERN Document Server

    REA, The Editors of; Staff of Research Education Association

    1989-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Numerical Analysis II covers simultaneous linear systems and matrix methods, differential equations, Fourier transformations, partial differential equations, and Monte Carlo methods.

  13. cobalt (ii), nickel (ii)

    African Journals Online (AJOL)

    DR. AMINU

    Department of Chemistry Bayero University, P. M. B. 3011, Kano, Nigeria. E-mail: hnuhu2000@yahoo.com. ABSTRACT. The manganese (II), cobalt (II), nickel (II) and .... water and common organic solvents, but are readily soluble in acetone. The molar conductance measurement [Table 3] of the complex compounds in.

  14. New spectroscopic results in Xe II, Xe III, and Xe IV

    OpenAIRE

    Reyna Almandos, Jorge Guillermo; Gallardo, Mario; Garavaglia, Mario J.

    1982-01-01

    New results obtained in spontaneous xenon spectrum employing a conventional pulsed gaseous laser tube as light source, are presented in this work. A total of 626 spectral lines has been ionically assigned as follows: 50 to Xe II spectrum, 103 to Xe III spectrum, arid 222 to Xe IV spectrum. 30 Lines previously assigned to Xe II were reassigned as belonging to Xe III, 94 lines were assigned with some doubts to Xe II-III spectrum and 84 lines to Xe Ill-IV spectrum. Also there were clas...

  15. Status of the Warm Front End of PIP-II Injector Test

    Energy Technology Data Exchange (ETDEWEB)

    Shemyakin, Alexander [Fermilab; Alvarez, Matthew [Fermilab; Andrews, Richard [Fermilab; Baffes, Curtis [Fermilab; Carneiro, Jean-Paul [Fermilab; Chen, Alex [Fermilab; Derwent, Paul [Fermilab; Edelen, Jonathan [Fermilab; Frolov, Daniil [Fermilab; Hanna, Bruce [Fermilab; Prost, Lionel [Fermilab; Saewert, Gregory [Fermilab; Saini, Arun [Fermilab; Scarpine, Victor [Fermilab; Sista, V. Lalitha [Fermilab; Steimel, Jim [Fermilab; Sun, Ding [Fermilab; Warner, Arden [Fermilab

    2017-05-01

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H⁻ SRF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10 mA DC, 30 keV H⁻ ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the warm front end.

  16. Target station design for a 1 MW pulsed spallation neutron source

    International Nuclear Information System (INIS)

    Russell, G.J.; Baker, G.D.; Brewton, R.J.

    1993-01-01

    Target stations are vital components of the 1 MW, next generation spallation neutron source proposed for LANSCE. By and large, target stations design determines the overall performance of the facility. Many traditional concepts will probably have to be rethought, and many new concepts will have to be put forward to meet the 1 MW challenge. This article gives a brief overview of the proposed neutron spallation source from the target station viewpoint, as well as the general philosophy adopted for the design of the LANSCE-II target stations. Some of the saliant concepts and features envisioned for LANSCE-II are briefly described

  17. Manufacturing of neutral beam sources at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Baird, E.D.; Duffy, T.J.; Harter, G.A.; Holland, E.D.; Kloos, W.A.; Pastrone, J.A.

    1979-01-01

    Over 50 neutral beam sources (NBS) of the joint Lawrence Berkeley Laboratory (LBL)/Lawrence Livermore Laboratory (LLL) design have been manufactured, since 1973, in the LLL Neutral Beam Source Facility. These sources have been used to provide start-up and sustaining neutral beams for LLL mirror fusion experiments, including 2XIIB, TMX, and Beta II. Experimental prototype 20-kV and 80-kV NBS have also been designed, built, and tested for the Mirror Fusion Test Facility (MFTF)

  18. Safety and environmental aspects of HYLIFE-II

    International Nuclear Information System (INIS)

    Dolan, T.J.; Longhurst, G.R.

    1990-01-01

    The HYLIFE-II inertial confinement fusion reactor uses a Flibe spray for blast chamber protection and tritium breeding. HYLIFE-II is passively safe, having no large sources of energy available to disperse radioactive materials. The dominant activation product is 18 F (half-life 110 minutes). Only a small fraction ( -5 ) of the Flibe activation products would be mobilized. The offsite dose from a severe accident involving simultaneous failure of the blast chamber and containment building would be < 0.2 mSv (20 mrem), and N-stamp requirements could be avoided in the blast chamber and coolant systems. The required tritium removal efficiencies are quantified. 10 refs., 1 fig

  19. Configuration of electro-optic fire source detection system

    Science.gov (United States)

    Fabian, Ram Z.; Steiner, Zeev; Hofman, Nir

    2007-04-01

    The recent fighting activities in various parts of the world have highlighted the need for accurate fire source detection on one hand and fast "sensor to shooter cycle" capabilities on the other. Both needs can be met by the SPOTLITE system which dramatically enhances the capability to rapidly engage hostile fire source with a minimum of casualties to friendly force and to innocent bystanders. Modular system design enable to meet each customer specific requirements and enable excellent future growth and upgrade potential. The design and built of a fire source detection system is governed by sets of requirements issued by the operators. This can be translated into the following design criteria: I) Long range, fast and accurate fire source detection capability. II) Different threat detection and classification capability. III) Threat investigation capability. IV) Fire source data distribution capability (Location, direction, video image, voice). V) Men portability. ) In order to meet these design criteria, an optimized concept was presented and exercised for the SPOTLITE system. Three major modular components were defined: I) Electro Optical Unit -Including FLIR camera, CCD camera, Laser Range Finder and Marker II) Electronic Unit -including system computer and electronic. III) Controller Station Unit - Including the HMI of the system. This article discusses the system's components definition and optimization processes, and also show how SPOTLITE designers successfully managed to introduce excellent solutions for other system parameters.

  20. Data structures II essentials

    CERN Document Server

    Smolarski, Dennis C

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Data Structures II includes sets, trees, advanced sorting, elementary graph theory, hashing, memory management and garbage collection, and appendices on recursion vs. iteration, alge

  1. The relationship between Class I and Class II methanol masers at high angular resolution

    Science.gov (United States)

    McCarthy, T. P.; Ellingsen, S. P.; Voronkov, M. A.; Cimò, G.

    2018-06-01

    We have used the Australia Telescope Compact Array (ATCA) to make the first high-resolution observations of a large sample of class I methanol masers in the 95-GHz (80-71A+) transition. The target sources consist of a statistically complete sample of 6.7-GHz class II methanol masers with an associated 95-GHz class I methanol maser, enabling a detailed study of the relationship between the two methanol maser classes at arcsecond angular resolution. These sources have been previously observed at high resolution in the 36- and 44-GHz transitions, allowing comparison between all three class I maser transitions. In total, 172 95-GHz maser components were detected across the 32 target sources. We find that at high resolution, when considering matched maser components, a 3:1 flux density ratio is observed between the 95- and 44-GHz components, consistent with a number of previous lower angular resolution studies. The 95-GHz maser components appear to be preferentially located closer to the driving sources and this may indicate that this transition is more strongly inverted nearby to background continuum sources. We do not observe an elevated association rate between 95-GHz maser emission and more evolved sources, as indicated by the presence of 12.2-GHz class II masers. We find that in the majority of cases where both class I and class II methanol emission is observed, some component of the class I emission is associated with a likely outflow candidate.

  2. Renewable energy sources. European Commission papers

    International Nuclear Information System (INIS)

    1997-05-01

    The ''Directive on the Promotion of Electricity from Renewable Sources of Energy in the Internal Electricity Market'' was adopted in September 2001. Its purpose is to promote an increase in the contribution of renewable energy sources to electricity production in the internal market for electricity and to create a basis for a future Community framework. Energie-Cites provides in this document a summary of its opinion on the Green Paper and on Alterner II and gives a proposal for an Action Plan concerning the White Paper. (A.L.B.)

  3. Geochemical characteristics of Lower Jurassic source rocks in the Zhongkouzi Basin

    Science.gov (United States)

    Niu, Haiqing; Han, Xiaofeng; Wei, Jianshe; Zhang, Huiyuan; Wang, Baowen

    2018-01-01

    Zhongkouzi basin is formed in Mesozoic and Cenozoic and developed on the Hercynian folded belt, the degree of exploration for oil and gas is relatively low hitherto. In order to find out the geochemical characteristics of the source rocks and the potentials for hydrocarbon generation. The research result shows that by analysis the geochemical characteristics of outcrop samples and new core samples in Longfengshan Group, Longfengshan Group are most developed intervals of favorable source rocks. They are formed in depression period of the basin when the sedimentary environments is salt water lacustrine and the water is keeping stable; The organic matter abundance is middle-higher, the main kerogen type is II1-II2 and few samples act as III type, The organic matter maturity is low maturity to medium maturity. The organic matter maturity of the source rock from eastern part of the basin is higher than in the western region. The source rock of Longfengshan Group are in the hydrocarbon generation threshold. The great mass of source rocks are matured and in the peak stage of oil generation.

  4. Cr(III,Mn(II,Fe(III,Co(II,Ni(II,Cu(II and Zn(II Complexes with Diisobutyldithiocarbamato Ligand

    Directory of Open Access Journals (Sweden)

    Mohammad Tarique

    2011-01-01

    Full Text Available The synthesis of sulphur and nitrogen containing dithiocarbamato ligand derived from diisobutylamine as well as its coordination compounds with 3d series transition metals is presented. These synthesized compounds were characterized on the basis of elemental analysis, conductometric measurements and IR spectral studies. The analytical data showed the stoichiometry 1:2 and 1:3 for the compounds of the types ML2 {M=Mn(II, Co(II, Ni(II, Cu(II and Zn(II} and M'L3{M'=Cr(III and Fe(III} respectively. The conductometric measurements proved the non-electrolytic behaviour of all the compounds. The bidentate nature of dithiocarbamato moiety was confirmed on the basis of IR spectral data.

  5. Operational Experience from LCLS-II Cryomodule Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Renzhuo [Fermilab; Hansen, Benjamin [Fermilab; White, Michael [Fermilab; Hurd, Joseph [Fermilab; Atassi, Omar Al [Fermilab; Bossert, Richard [Fermilab; Pei, Liujin [Fermilab; Klebaner, Arkadiy [Fermilab; Makara, Jerry [Fermilab; Theilacker, Jay [Fermilab; Kaluzny, Joshua [Fermilab; Wu, Genfa [Fermilab; Harms, Elvin [Fermilab

    2017-07-01

    This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.

  6. Operational experience from LCLS-II cryomodule testing

    Science.gov (United States)

    Wang, R.; Hansen, B.; White, M.; Hurd, J.; Atassi, O. Al; Bossert, R.; Pei, L.; Klebaner, A.; Makara, J.; Theilacker, J.; Kaluzny, J.; Wu, G.; Harms, E.

    2017-12-01

    This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.

  7. IIS--Integrated Interactome System: a web-based platform for the annotation, analysis and visualization of protein-metabolite-gene-drug interactions by integrating a variety of data sources and tools.

    Science.gov (United States)

    Carazzolle, Marcelo Falsarella; de Carvalho, Lucas Miguel; Slepicka, Hugo Henrique; Vidal, Ramon Oliveira; Pereira, Gonçalo Amarante Guimarães; Kobarg, Jörg; Meirelles, Gabriela Vaz

    2014-01-01

    High-throughput screening of physical, genetic and chemical-genetic interactions brings important perspectives in the Systems Biology field, as the analysis of these interactions provides new insights into protein/gene function, cellular metabolic variations and the validation of therapeutic targets and drug design. However, such analysis depends on a pipeline connecting different tools that can automatically integrate data from diverse sources and result in a more comprehensive dataset that can be properly interpreted. We describe here the Integrated Interactome System (IIS), an integrative platform with a web-based interface for the annotation, analysis and visualization of the interaction profiles of proteins/genes, metabolites and drugs of interest. IIS works in four connected modules: (i) Submission module, which receives raw data derived from Sanger sequencing (e.g. two-hybrid system); (ii) Search module, which enables the user to search for the processed reads to be assembled into contigs/singlets, or for lists of proteins/genes, metabolites and drugs of interest, and add them to the project; (iii) Annotation module, which assigns annotations from several databases for the contigs/singlets or lists of proteins/genes, generating tables with automatic annotation that can be manually curated; and (iv) Interactome module, which maps the contigs/singlets or the uploaded lists to entries in our integrated database, building networks that gather novel identified interactions, protein and metabolite expression/concentration levels, subcellular localization and computed topological metrics, GO biological processes and KEGG pathways enrichment. This module generates a XGMML file that can be imported into Cytoscape or be visualized directly on the web. We have developed IIS by the integration of diverse databases following the need of appropriate tools for a systematic analysis of physical, genetic and chemical-genetic interactions. IIS was validated with yeast two

  8. The rotation measures of radio sources and their interpretation

    International Nuclear Information System (INIS)

    Vallee, J.P.; Kronberg, P.P.

    1975-01-01

    Rotation measures of 251 discrete radio sources have been determined after incorporating new polarization data at short wavelenghts. These have been applied to a 'slab' model-fitting technique to determine the most likely spiral arm magnetic field structure. The best agreement is obtained for a longitudinal spiral arm magnetic field, directed toward (lII approximately 90 0 , bII approximately 0 0 ), but perturbed by an anomaly towards the North Galactic Spur. (orig.) [de

  9. Geochemical characteristics of Holocene laminated sapropel (unit II) and underlying lacustrine unit III in the Black Sea

    Science.gov (United States)

    Dean, Walter E.; Arthur, Michael A.

    2011-01-01

    eg 1 of the 1988 R/V Knorr expeditions to the Black Sea recovered 90 gravity and box cores. The longest recovery by gravity cores was about 3 meters, with an average of about 2.5 meters, recovering all of the Holocene and upper Pleistocene sections in the Black Sea. During the latest Pleistocene glaciation, sea level dropped below the 35-meters-deep Bosporus outlet sill of the Black Sea. Therefore throughout most of its history the Black Sea was a lake, and most of its sediments are lacustrine. The oldest sediments recovered (older than 8,000 calendar years) consist of massive to coarsely banded lacustrine calcareous clay designated as lithologic Unit III, generally containing less than 1 percent organic carbon (OC). The base of overlying Unit II marks the first incursion of Mediterranean seawater into the Black Sea, and the onset of bottom-water anoxia about 7,900 calendar years. Unit II contains as much as 15 percent OC in cores from the deepest part of the Black Sea (2,200 meters). The calcium carbonate (CaCO3) remains of the coccolith Emiliania huxleyi form the distinctive white laminae of overlying Unit I. The composition of Unit III and Unit II sediments are quite different, reflecting different terrigenous clastic sources and increased contributions from hydrogenous and biogenic components in anoxic Unit II sapropel. In Unit II, positive covariance between OC and three trace elements commonly concentrated in OC-rich sediments where sulfate reduction has occurred (molybdenum, nickel, and vanadium) and a nutrient (phosphorus) suggest a large marine source for these elements although nickel and vanadium also have a large terrigenous clastic source. The marine sources may be biogenic or hydrogenous. A large biogenic source is also suggested for copper and cobalt. Because abundant pyrite forms in the water column and sediments of the Black Sea, we expected to find a large hydrogenous iron component, but a strong covariance of iron with aluminum suggests that the

  10. General-purpose heat source development. Phase II: conceptual designs

    International Nuclear Information System (INIS)

    Snow, E.C.; Zocher, R.W.; Grinberg, I.M.; Hulbert, L.E.

    1978-11-01

    Basic geometric module shapes and fuel arrays were studied to determine how well they could be expected to meet the General Purpose Heat Source (GPHS) design requirements. Seven conceptual designs were selected, detailed drawings produced, and these seven concepts analyzed. Three of these design concepts were selected as GPHS Trial Designs to be reanalyzed in more detail and tested. The geometric studies leading to the selection of the seven conceptual designs, the analyses of these designs, and the selection of the three trial designs are discussed

  11. Computer augumented modelling studies of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid in 1,2-propanediol–water mixtures

    Directory of Open Access Journals (Sweden)

    MAHESWARA RAO VEGI

    2008-12-01

    Full Text Available Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid was studied at 303 K in 0–60 vol. % 1,2-propanediol–water mixtures, whereby the ionic strength was maintained at 0.16 mol dm-3. The active forms of the ligand are LH3+, LH2 and LH–. The predominant detected species were ML, ML2, MLH, ML2H and ML2H2. The trend of the variation in the stability constants with changing dielectric constant of the medium is explained based on the cation stabilizing nature of the co-solvents, specific solvent–water interactions, charge dispersion and specific interactions of the co-solvent with the solute. The effect of systematic errors in the concentrations of the substances on the stability constants is in the order alkali > > acid > ligand > metal. The bioavailability and transportation of metals are explained based on distribution diagrams and stability constants.

  12. Synthesis and characterization of heterobimetallic complexes of the type [Cu(pn2][MCl4] where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II, and Hg(II

    Directory of Open Access Journals (Sweden)

    Seema Yadav

    2016-11-01

    Full Text Available A series of new bimetallic transition metal complexes of the type [Cu(pn2] [MCl4] have been synthesized (where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II and Hg(II, pn = 1,3-diaminopropane and characterized by elemental analysis, molar conductance, TGA, IR and electronic spectra. All the compounds are 1:1 electrolyte in DMF. The Cu(II ion is square-planar while metal ions in the anionic moiety acquire their usual tetrahedral arrangement. On the basis of these studies it is concluded that anionic moiety is electrically stabilized by its cationic counterpart.

  13. NSLS-II Preliminary Design Report

    International Nuclear Information System (INIS)

    Dierker, S.

    2007-01-01

    Following the CD0 approval of the National Synchrotron Light Source II (NSLS-II) during August 2005, Brookhaven National Laboratory prepared a conceptual design for a worldclass user facility for scientific research using synchrotron radiation. DOE SC review of the preliminary baseline in December 2006 led to the subsequent CD1 approval (approval of alternative selection and cost range). This report is the documentation of the preliminary design work for the NSLS-II facility. The preliminary design of the Accelerator Systems (Part 1) was developed mostly based of the Conceptual Design Report, except for the Booster design, which was changed from in-storage-ring tunnel configuration to in external- tunnel configuration. The design of beamlines (Part 2) is based on designs developed by engineering firms in accordance with the specification provided by the Project. The conventional facility design (Part 3) is the Title 1 preliminary design by the AE firm that met the NSLS-II requirements. Last and very important, Part 4 documents the ES and H design and considerations related to this preliminary design. The NSLS-II performance goals are motivated by the recognition that major advances in many important technology problems will require scientific breakthroughs in developing new materials with advanced properties. Achieving this will require the development of new tools that will enable the characterization of the atomic and electronic structure, chemical composition, and magnetic properties of materials, at nanoscale resolution. These tools must be nondestructive, to image and characterize buried structures and interfaces, and they must operate in a wide range of temperatures and harsh environments. The NSLS-II facility will provide ultra high brightness and flux and exceptional beam stability. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the

  14. NSLS-II Preliminary Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Dierker, S.

    2007-11-01

    Following the CD0 approval of the National Synchrotron Light Source II (NSLS-II) during August 2005, Brookhaven National Laboratory prepared a conceptual design for a worldclass user facility for scientific research using synchrotron radiation. DOE SC review of the preliminary baseline in December 2006 led to the subsequent CD1 approval (approval of alternative selection and cost range). This report is the documentation of the preliminary design work for the NSLS-II facility. The preliminary design of the Accelerator Systems (Part 1) was developed mostly based of the Conceptual Design Report, except for the Booster design, which was changed from in-storage-ring tunnel configuration to in external- tunnel configuration. The design of beamlines (Part 2) is based on designs developed by engineering firms in accordance with the specification provided by the Project. The conventional facility design (Part 3) is the Title 1 preliminary design by the AE firm that met the NSLS-II requirements. Last and very important, Part 4 documents the ES&H design and considerations related to this preliminary design. The NSLS-II performance goals are motivated by the recognition that major advances in many important technology problems will require scientific breakthroughs in developing new materials with advanced properties. Achieving this will require the development of new tools that will enable the characterization of the atomic and electronic structure, chemical composition, and magnetic properties of materials, at nanoscale resolution. These tools must be nondestructive, to image and characterize buried structures and interfaces, and they must operate in a wide range of temperatures and harsh environments. The NSLS-II facility will provide ultra high brightness and flux and exceptional beam stability. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the facility

  15. Shape analysis of pulsed second sound in He II

    International Nuclear Information System (INIS)

    Worthington, T.; Yan, J.; Trefny, J.U.

    1976-01-01

    Second sound in He II has been observed using a heat pulse method. At temperatures where well-developed second sound is observed, the entire pulse shape can be understood if heat sources and geometrical effects are properly taken into account. 4 figures

  16. Industrialization of the nitrogen-doping preparation for SRF cavities for LCLS-II

    Science.gov (United States)

    Gonnella, D.; Aderhold, S.; Burrill, A.; Daly, E.; Davis, K.; Grassellino, A.; Grimm, C.; Khabiboulline, T.; Marhauser, F.; Melnychuk, O.; Palczewski, A.; Posen, S.; Ross, M.; Sergatskov, D.; Sukhanov, A.; Trenikhina, Y.; Wilson, K. M.

    2018-03-01

    The Linac Coherent Light Source II (LCLS-II) is a new state-of-the-art coherent X-ray source being constructed at SLAC National Accelerator Laboratory. It employs 280 superconducting radio frequency (SRF) cavities in order operate in continuous wave (CW) mode. To reduce the overall cryogenic cost of such a large accelerator, nitrogen-doping of the SRF cavities is being used. Nitrogen-doping has consistently been shown to increase the efficiency of SRF cavities operating in the 2.0 K regime and at medium fields (15-20 MV/m) in vertical cavity tests and horizontal cryomodule tests. While nitrogen-doping's efficacy for improvement of cavity performance was demonstrated at three independent labs, Fermilab, Jefferson Lab, and Cornell University, transfer of the technology to industry for LCLS-II production was not without challenges. Here we present results from the beginning of LCLS-II cavity production. We discuss qualification of the cavity vendors and the first cavities from each vendor. Finally, we demonstrate that nitrogen-doping has been successfully transferred to SRF cavity vendors, resulting in consistent production of cavities with better cryogenic efficiency than has ever been achieved for a large-scale accelerator.

  17. Saudis trust and confidence in information sources about chemical ...

    African Journals Online (AJOL)

    AJL

    To communicate information on chemical pollution health risks effectively, policy makers must know .... opinions, and perception of environmental health risks,. (ii) know their .... information on health risks from multiple sources. Similarly when ...

  18. Computer science II essentials

    CERN Document Server

    Raus, Randall

    2012-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Computer Science II includes organization of a computer, memory and input/output, coding, data structures, and program development. Also included is an overview of the most commonly

  19. A kinetic and ESR investigation of iron(II) oxalate oxidation by hydrogen peroxide and dioxygen as a source of hydroxyl radicals

    DEFF Research Database (Denmark)

    Park, J S; Wood, P M; Davies, Michael Jonathan

    1997-01-01

    The reaction of Fe(II) oxalate with hydrogen peroxide and dioxygen was studied for oxalate concentrations up to 20 mM and pH 2-5, under which conditions mono- and bis-oxalate complexes (Fe[II](ox) and Fe[II](ox)2[2-]) and uncomplexed Fe2+ must be considered. The reaction of Fe(II) oxalate...... with hydrogen peroxide (Fe2+ + H2O2 --> Fe3+ + .OH + OH-) was monitored in continuous flow by ESR with t-butanol as a radical trap. The reaction is much faster than for uncomplexed Fe2+ and a rate constant, k = 1 x 10(4) M(-1) s(-1) is deduced for Fe(II)(ox). The reaction of Fe(II) oxalate with dioxygen...... by oxalate. Further ESR studies with DMPO as spin trap reveal that reaction of Fe(II) oxalate with hydrogen peroxide can also lead to formation of the carboxylate radical anion (CO2-), an assignment confirmed by photolysis of Fe(II) oxalate in the presence of DMPO....

  20. The EBR-II Probabilistic Risk Assessment: lessons learned regarding passive safety

    International Nuclear Information System (INIS)

    Hill, D.J.; Ragland, W.A.; Roglans, J.

    1998-01-01

    This paper summarizes the results from the EBR-II Probabilistic Risk Assessment (PRA) and provides an analysis of the source of risk of the operation of EBR-II from both internal and external initiating events. The EBR-II PRA explicitly accounts for the role of reactivity feedbacks in reducing fuel damage. The results show that the expected core damage frequency from internal initiating events at EBR-II is very low, 1.6 10 -6 yr -1 , even with a wide definition of core damage (essentially that of exceeding Technical Specification limits). The annual frequency of damage, primarily due to liquid metal fires, from externally initiated events (excluding earthquakes) is 3.6 10 -6 yr -1 and the contribution of seismic events is 1.7 10 -5 yr -1 . Overall these results are considerably better than results for other research reactors and the nuclear industry in general and stem from three main sources: low likelihood of loss of coolant due to low system pressure and top entry double vessels; low likelihood of loss of decay heat removal due to reliance on passive means; and low likelihood of power/flow mismatch due to both passive feedbacks and reliability of rod scram capability

  1. The EBR-II Probabilistic Risk Assessment: lessons learned regarding passive safety

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D J; Ragland, W A; Roglans, J

    1998-11-01

    This paper summarizes the results from the EBR-II Probabilistic Risk Assessment (PRA) and provides an analysis of the source of risk of the operation of EBR-II from both internal and external initiating events. The EBR-II PRA explicitly accounts for the role of reactivity feedbacks in reducing fuel damage. The results show that the expected core damage frequency from internal initiating events at EBR-II is very low, 1.6 10{sup -6} yr{sup -1}, even with a wide definition of core damage (essentially that of exceeding Technical Specification limits). The annual frequency of damage, primarily due to liquid metal fires, from externally initiated events (excluding earthquakes) is 3.6 10{sup -6} yr{sup -1} and the contribution of seismic events is 1.7 10{sup -5} yr{sup -1}. Overall these results are considerably better than results for other research reactors and the nuclear industry in general and stem from three main sources: low likelihood of loss of coolant due to low system pressure and top entry double vessels; low likelihood of loss of decay heat removal due to reliance on passive means; and low likelihood of power/flow mismatch due to both passive feedbacks and reliability of rod scram capability.

  2. The EBR-II probabilistic risk assessment lessons learned regarding passive safety

    International Nuclear Information System (INIS)

    Hill, D.J.; Ragland, W.A.; Roglans, J.

    1994-01-01

    This paper summarizes the results from the recently completed EBR-II Probabilistic Risk Assessment (PRA) and provides an analysis of the source of risk of the operation of EBR-II from both internal and external initiating events. The EBR-II PRA explicitly accounts for the role of reactivity feedbacks in reducing fuel damage. The results show that the expected core damage frequency from internal initiating events at EBR-II is very low, 1.6 10 -6 yr -1 , even with a wide definition of core damage (essentially that of exceeding Technical Specification limits). The annual frequency of damage, primarily due to liquid metal fires, from externally initiated events (excluding earthquakes) is 3.6 10 -6 yr -1 and the contribution of seismic events is 1.7 10 -5 yr -1 . Overall these results are considerably better than results for other research reactors and the nuclear industry in general and stem from three main sources: low likelihood of loss of coolant due to low system pressure and top entry double vessels; low likelihood of loss of decay heat removal due to reliance on passive means; and low likelihood of power/flow mismatch due to both passive feedbacks and reliability of rod scram capability

  3. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  4. Synthesis and structural characterization of nickel(II), cobalt(II), Zinc(II), manganese(II), cadmium(II) and uranium(VI) complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazone

    International Nuclear Information System (INIS)

    Patel, P.S.; Patel, M.M.; Ray, R.M.

    1993-01-01

    A few metal complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazones (OAOATS)/(OAPATS) with Ni(II), Co(II), Zn(II), Mn(II), Hg(II), Cd(II) and UO 2 (II) have been prepared and characterized by elemental analyses, conductivity, differential scanning calorimetry study, thermogravimetric analyses and infrared and electronic spectral measurements in conjunction with magnetic susceptibility measurements at room temperature. They have also been tested for their antimicrobial activities. (author). 24 refs., 2 tabs

  5. Fiber Coupled Pulse Shaper for Sub-Nanosecond Pulse Lidar, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II effort will develop an all-diode laser and fiber optic based, single frequency, sub-nanosecond pulsed laser source...

  6. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    International Nuclear Information System (INIS)

    Xue Yongjie; Hou Haobo; Zhu Shujing

    2009-01-01

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO 3 . In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH 50 (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems

  7. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yongjie [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China); Wuhan Kaidi Electric Power Environmental Protection Co. Ltd., Hubei, Wuhan (China)], E-mail: xueyj@mail.whut.edu.cn; Hou Haobo; Zhu Shujing [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China)

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO{sub 3}. In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH{sub 50} (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  8. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag.

    Science.gov (United States)

    Xue, Yongjie; Hou, Haobo; Zhu, Shujing

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01M NaNO(3). In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84mM in the single element system and 0.21mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH(50) (the pH at which 50% adsorption occurs) was found to follow the sequence Zn>Cu>Pb>Cd in single-element systems, but Pb>Cu>Zn>Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  9. The influence of Fe(II) competition on the sorption and migration of Ni(II) in MX-80 bentonite

    International Nuclear Information System (INIS)

    Pfingsten, Wilfried; Bradbury, Mike; Baeyens, Bart

    2011-01-01

    two competing sorbates and their respective concentrations. At background Fe(II) concentrations of 5.3 x 10 -5 M, and a Ni(II) EQBM level of 10 -7 M, the Ni(II) breakthrough time was ∼15 times earlier than in the absence of competition. At such Fe(II) concentrations the Ni(II) breakthrough curves at all source concentrations less than 3.5 x 10 -5 M (fixed by the NiCO 3,S solubility limit) are the same i.e. Ni(II) exhibits linear (low) sorption. Competitive sorption effects can have significant influences on the transport of radionuclides through compacted bentonite i.e. reduce the migration rates. Since, for the case considered here, the Fe(II) concentration in the near field of a high-level radioactive waste repository may change in time and space, the transport of bivalent transition metal radionuclides can only be properly modelled using a multi-species reactive transport code which includes a sorption model.

  10. Preparation of Schiff s base complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II) and their spectroscopic, magnetic, thermal, and antifungal studies

    International Nuclear Information System (INIS)

    Parekh, H.M.; Patel, M.N.

    2006-01-01

    The potassium salt of salicylidene-DL-alanine (KHL), bis(benzylidene)ethylenediamine (A 1 ), thiophene-o-carboxaldene-p-toluidine (A 2 ), and its metal complexes of the formula [(M II (L)(A)(H 2 O)] (M=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II); A = A 1 or A 2 ) are prepared. They are characterized by elemental analysis, magnetic susceptibility measurements, thermogravimetric analysis, and infrared and electronic spectral studies. The electronic spectral and magnetic moment data suggest an octahedral geometry for the complexes. All of these complexes, metal nitrates, fungicides (bavistin and emcarb), and ligands are screened for their antifungal activity against Aspergillus niger, Fusarium oxysporum, and Aspergillus flavus using a plate poison technique. The complexes show higher activity than those of the free ligands, metal nitrate, and the control (DMSO) and moderate activity against bavistin and emcarb [ru

  11. Wavelengths, energy levels and hyperfine structure of Mn II and Sc II.

    Science.gov (United States)

    Nave, Gillian; Pickering, Juliet C.; Townley-Smith, Keeley I. M.; Hala, .

    2015-08-01

    For many decades, the Atomic Spectroscopy Groups at the National Institute of Standards and Technology (NIST) and Imperial College London (ICL) have measured atomic data of astronomical interest. Our spectrometers include Fourier transform (FT) spectrometers at NIST and ICL covering the region 1350 Å to 5.5 μm and a 10.7-m grating spectrometer at NIST covering wavelengths from 300 - 5000 Å. Sources for these spectra include high-current continuous and pulsed hollow cathode (HCL) lamps, Penning discharges, and sliding spark discharges. Recent work has focused on the measurement and analysis of wavelengths, energy levels, and hyperfine structure (HFS) constants for iron-group elements. The analysis of FT spectra of Cr I, Mn I, and Mn II is being led by ICL and is described in a companion poster [1]. Current work being led by NIST includes the analysis of HFS in Mn II, analysis of Mn II in the vacuum ultraviolet, and a comprehensive analysis of Sc II.Comprehensive HFS constants for Mn II are needed for the interpretation of stellar spectra and incorrect abundances may be obtained when HFS is omitted. Holt et al. [2] have measured HFS constants for 59 levels of Mn II using laser spectroscopy. We used FT spectra of Mn/Ni and Mn/Cu HCLs covering wavelength ranges from 1350 Å to 5.4 μm to confirm 26 of the A constants of Holt et al. and obtain values for roughly 40 additional levels. We aim to obtain HFS constants for the majority of lines showing significant HFS that are observed in chemically-peculiar stars.Spectra of Sc HCLs have been recorded from 1800 - 6700 Å using a vacuum ultraviolet FT spectrometer at NIST. Additional measurements to cover wavelengths above 6700 Å and below 1800 Å are in progress. The spectra are being analyzed by NIST and Alighar Muslim University, India in order to derive improved wavelengths, energy levels, and hyperfine structure parameters.This work was partially supported by NASA, the STFC and PPARC (UK), the Royal Society of the UK

  12. The faint radio source population at 15.7 GHz - II. Multi-wavelength properties

    Science.gov (United States)

    Whittam, I. H.; Riley, J. M.; Green, D. A.; Jarvis, M. J.; Vaccari, M.

    2015-11-01

    A complete, flux density limited sample of 96 faint (>0.5 mJy) radio sources is selected from the 10C survey at 15.7 GHz in the Lockman Hole. We have matched this sample to a range of multi-wavelength catalogues, including Spitzer Extragalactic Representative Volume Survey, Spitzer Wide-area Infrared Extragalactic survey, United Kingdom Infrared Telescope Infrared Deep Sky Survey and optical data; multi-wavelength counterparts are found for 80 of the 96 sources and spectroscopic redshifts are available for 24 sources. Photometric redshifts are estimated for the sources with multi-wavelength data available; the median redshift of the sample is 0.91 with an interquartile range of 0.84. Radio-to-optical ratios show that at least 94 per cent of the sample are radio loud, indicating that the 10C sample is dominated by radio galaxies. This is in contrast to samples selected at lower frequencies, where radio-quiet AGN and star-forming galaxies are present in significant numbers at these flux density levels. All six radio-quiet sources have rising radio spectra, suggesting that they are dominated by AGN emission. These results confirm the conclusions of Paper I that the faint, flat-spectrum sources which are found to dominate the 10C sample below ˜1 mJy are the cores of radio galaxies. The properties of the 10C sample are compared to the Square Kilometre Array Design Studies Simulated Skies; a population of low-redshift star-forming galaxies predicted by the simulation is not found in the observed sample.

  13. Design and Fabrication of the Lithium Beam Ion Injector for NDCX-II

    International Nuclear Information System (INIS)

    Takakuwa, J.

    2011-01-01

    A 130 keV injector is developed for the NDCX-II facility. It consists of a 10.9 cm diameter lithium doped alumina-silicate ion source heated to ∼1300 C and 3 electrodes. Other components include a segmented Rogowski coil for current and beam position monitoring, a gate valve, pumping ports, a focusing solenoid, a steering coil and space for inspection and maintenance access. Significant design challenges including managing the 3-4 kW of power dissipation from the source heater, temperature uniformity across the emitter surface, quick access for frequent ion source replacement, mechanical alignment with tight tolerance, and structural stabilization of the cantilevered 27-inch OD graded HV ceramic column. The injector fabrication is scheduled to complete by May 2011, and assembly and installation is scheduled to complete by the beginning of July. The Neutralized Drift Compression eXperiment (NDCX-II) is for the study of high energy density physics and inertial fusion energy research utilizing a lithium ion (Li+) beam with a current of 93 mA and a pulse length of 500 ns (compressed to 1 ns at the target). The injector is one of the most complicated sections of the NDCX-II accelerator demanding significant design and fabrication resources. It needs to accommodate a relatively large ion source (10.9 cm), a high heat load (3-4 kW) and specific beam optics developed from the physics model. Some specific design challenges are noted in this paper.

  14. Cu(II) AND Zn(II)

    African Journals Online (AJOL)

    Preferred Customer

    SYNTHESIS OF 2,2-DIMETHYL-4-PHENYL-[1,3]-DIOXOLANE USING ZEOLITE. ENCAPSULATED Co(II), Cu(II) AND Zn(II) COMPLEXES. B.P. Nethravathi1, K. Rama Krishna Reddy2 and K.N. Mahendra1*. 1Department of Chemistry, Bangalore University, Bangalore-560001, India. 2Department of Chemistry, Government ...

  15. Narrow Wavelength, Frequency Modulated Source at 1.5 Wavelength, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Ultrastable, narrow linewidth, tunable, high reliability sources at 1.5 or 2mm are needed for high performance LIDARs for several NASA applications, including wind...

  16. Deep UV Semiconductor Sources for Advanced Planetary Science Instruments, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal addresses the need for miniature, narrow-linewidth, deep UV optical sources that operate at very low ambient temperatures for use in advanced in situ...

  17. Spectroscopic and thermal degradation behavior of Mg(II, Ca(II, Ba(II and Sr(II complexes with paracetamol drug

    Directory of Open Access Journals (Sweden)

    Moamen S. Refat

    2017-05-01

    Full Text Available Complexes of Mg(II, Ca(II, Ba(II and Sr(II with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical data, the stoichiometry of the complexes reacts with Mg(II, Ca(II, Ba(II and Sr(II by molar ratios (2:1 (paracetamol:metal ion. The thermal behavior (TG/DTG of the complexes was studied. The ligand and their metal complexes were screened against both of antibacterial and fungicidal activities.

  18. ON COMPUTING UPPER LIMITS TO SOURCE INTENSITIES

    International Nuclear Information System (INIS)

    Kashyap, Vinay L.; Siemiginowska, Aneta; Van Dyk, David A.; Xu Jin; Connors, Alanna; Freeman, Peter E.; Zezas, Andreas

    2010-01-01

    A common problem in astrophysics is determining how bright a source could be and still not be detected in an observation. Despite the simplicity with which the problem can be stated, the solution involves complicated statistical issues that require careful analysis. In contrast to the more familiar confidence bound, this concept has never been formally analyzed, leading to a great variety of often ad hoc solutions. Here we formulate and describe the problem in a self-consistent manner. Detection significance is usually defined by the acceptable proportion of false positives (background fluctuations that are claimed as detections, or Type I error), and we invoke the complementary concept of false negatives (real sources that go undetected, or Type II error), based on the statistical power of a test, to compute an upper limit to the detectable source intensity. To determine the minimum intensity that a source must have for it to be detected, we first define a detection threshold and then compute the probabilities of detecting sources of various intensities at the given threshold. The intensity that corresponds to the specified Type II error probability defines that minimum intensity and is identified as the upper limit. Thus, an upper limit is a characteristic of the detection procedure rather than the strength of any particular source. It should not be confused with confidence intervals or other estimates of source intensity. This is particularly important given the large number of catalogs that are being generated from increasingly sensitive surveys. We discuss, with examples, the differences between these upper limits and confidence bounds. Both measures are useful quantities that should be reported in order to extract the most science from catalogs, though they answer different statistical questions: an upper bound describes an inference range on the source intensity, while an upper limit calibrates the detection process. We provide a recipe for computing upper

  19. TANAMI: Tracking Active Galactic Nuclei with Austral Milliarcsecond Interferometry. II. Additional sources

    Science.gov (United States)

    Müller, C.; Kadler, M.; Ojha, R.; Schulz, R.; Trüstedt, J.; Edwards, P. G.; Ros, E.; Carpenter, B.; Angioni, R.; Blanchard, J.; Böck, M.; Burd, P. R.; Dörr, M.; Dutka, M. S.; Eberl, T.; Gulyaev, S.; Hase, H.; Horiuchi, S.; Katz, U.; Krauß, F.; Lovell, J. E. J.; Natusch, T.; Nesci, R.; Phillips, C.; Plötz, C.; Pursimo, T.; Quick, J. F. H.; Stevens, J.; Thompson, D. J.; Tingay, S. J.; Tzioumis, A. K.; Weston, S.; Wilms, J.; Zensus, J. A.

    2018-02-01

    Context. TANAMI is a multiwavelength program monitoring active galactic nuclei (AGN) south of - 30° declination including high-resolution very long baseline interferometry (VLBI) imaging, radio, optical/UV, X-ray, and γ-ray studies. We have previously published first-epoch8.4 GHz VLBI images of the parsec-scale structure of the initial sample. In this paper, we present images of 39 additional sources. The full sample comprises most of the radio- and γ-ray brightest AGN in the southern quarter of the sky, overlapping with the region from which high-energy (> 100 TeV) neutrino events have been found. Aims: We characterize the parsec-scale radio properties of the jets and compare them with the quasi-simultaneous Fermi/LAT γ-ray data. Furthermore, we study the jet properties of sources which are in positional coincidence with high-energy neutrino events compared to the full sample. We test the positional agreement of high-energy neutrino events with various AGN samples. Methods: TANAMI VLBI observations at 8.4 GHz are made with southern hemisphere radio telescopes located in Australia, Antarctica, Chile, New Zealand, and South Africa. Results: Our observations yield the first images of many jets below - 30° declination at milliarcsecond resolution. We find that γ-ray loud TANAMI sources tend to be more compact on parsec-scales and have higher core brightness temperatures than γ-ray faint jets, indicating higher Doppler factors. No significant structural difference is found between sources in positional coincidence with high-energy neutrino events and other TANAMI jets. The 22 γ-ray brightest AGN in the TANAMI sky show only a weak positional agreement with high-energy neutrinos demonstrating that the > 100 TeV IceCube signal is not simply dominated by a small number of the γ-ray brightest blazars. Instead, a larger number of sources have to contribute to the signal with each individual source having only a small Poisson probability for producing an event in

  20. Low Complexity Bayesian Single Channel Source Separation

    DEFF Research Database (Denmark)

    Beierholm, Thomas; Pedersen, Brian Dam; Winther, Ole

    2004-01-01

    can be estimated quite precisely using ML-II, but the estimation is quite sensitive to the accuracy of the priors as opposed to the source separation quality for known mixing coefficients, which is quite insensitive to the accuracy of the priors. Finally, we discuss how to improve our approach while...

  1. High resolution far-infrared survey of A section of the galactic plane. I. The nature of the sources

    International Nuclear Information System (INIS)

    Jaffe, D.T.; Stier, M.T.; Fazio, G.G.

    1982-01-01

    We have surveyed a 7.5 deg 2 portion of the galactic plane between l/sup II/ = 10 0 and l/sup II/ = 16 0 at 70 μm with a 1' beam. We present far-infrared, radio continuum, and 12 CO and 13 CO line observations of the 42 far-infrared sources in the survey region. The sources range in luminosity from 4 x 10 3 to 3 x 10 6 L/sub sun/. Most are associated with 12 CO peaks. More than half of the sources have associated H 2 O maser emission. Half have associated radio continuum emission at a limit of 100 mJy. Eight sources have radio emission at weaker levels. In a number of cases, the far-infrared source is smaller than its associated radio source. This difference can be explained in the context of the ''blister'' picture of H II regions. One group of sources emits many fewer Lyman continuum photons than expected, given the far-infrared luminosities. We examine a number of possible reasons for this and conclude that the most reasonable explanation is that clusters of early type stars rather than single stars excite the far-infrared sources. We examine the energetics in the molecular clouds surrounding the infrared sources and conclude that the sources could supply the energy to explain the observed temperature structure and velocity field in the molecular gas

  2. Solar photocatalytic removal of Cu(II), Ni(II), Zn(II) and Pb(II): Speciation modeling of metal-citric acid complexes

    International Nuclear Information System (INIS)

    Kabra, Kavita; Chaudhary, Rubina; Sawhney, R.L.

    2008-01-01

    The present study is targeted on solar photocatalytic removal of metal ions from wastewater. Photoreductive deposition and dark adsorption of metal ions Cu(II), Ni(II), Pb(II) and Zn(II), using solar energy irradiated TiO 2 , has been investigated. Citric acid has been used as a hole scavenger. Modeling of metal species has been performed and speciation is used as a tool for discussing the photodeposition trends. Ninety-seven percent reductive deposition was obtained for copper. The deposition values of other metals were significantly low [nickel (36.4%), zinc (22.2%) and lead (41.4%)], indicating that the photocatalytic treatment process, using solar energy, was more suitable for wastewater containing Cu(II) ions. In absence of citric acid, the decreasing order deposition was Cu(II) > Ni(II) > Pb(II) > Zn(II), which proves the theoretical thermodynamic predictions about the metals

  3. Cd(II), Cu(II)

    African Journals Online (AJOL)

    user

    Depending on the way goethite was pretreated with oxalic acid, affinity for Cd(II) varied ...... Effects and mechanisms of oxalate on Cd(II) adsorption on goethite at different ... precipitation, surfactant mediation, hydrothermal and micro-emulsion.

  4. Simultaneous Femtosecond X-ray Spectroscopy and Diffraction of Photosystem II at Room Temperature

    Science.gov (United States)

    Kern, Jan; Alonso-Mori, Roberto; Tran, Rosalie; Hattne, Johan; Gildea, Richard J.; Echols, Nathaniel; Glöckner, Carina; Hellmich, Julia; Laksmono, Hartawan; Sierra, Raymond G.; Lassalle-Kaiser, Benedikt; Koroidov, Sergey; Lampe, Alyssa; Han, Guangye; Gul, Sheraz; DiFiore, Dörte; Milathianaki, Despina; Fry, Alan R.; Miahnahri, Alan; Schafer, Donald W.; Messerschmidt, Marc; Seibert, M. Marvin; Koglin, Jason E.; Sokaras, Dimosthenis; Weng, Tsu-Chien; Sellberg, Jonas; Latimer, Matthew J.; Grosse-Kunstleve, Ralf W.; Zwart, Petrus H.; White, William E.; Glatzel, Pieter; Adams, Paul D.; Bogan, Michael J.; Williams, Garth J.; Boutet, Sébastien; Messinger, Johannes; Zouni, Athina; Sauter, Nicholas K.; Yachandra, Vittal K.; Bergmann, Uwe; Yano, Junko

    2013-01-01

    Intense femtosecond X-ray pulses produced at the Linac Coherent Light Source (LCLS) were used for simultaneous X-ray diffraction (XRD) and X-ray emission spectroscopy (XES) of microcrystals of Photosystem II (PS II) at room temperature. This method probes the overall protein structure and the electronic structure of the Mn4CaO5 cluster in the oxygen-evolving complex of PS II. XRD data are presented from both the dark state (S1) and the first illuminated state (S2) of PS II. Our simultaneous XRD/XES study shows that the PS II crystals are intact during our measurements at the LCLS, not only with respect to the structure of PS II, but also with regard to the electronic structure of the highly radiation sensitive Mn4CaO5 cluster, opening new directions for future dynamics studies. PMID:23413188

  5. Open-access MIMIC-II database for intensive care research.

    Science.gov (United States)

    Lee, Joon; Scott, Daniel J; Villarroel, Mauricio; Clifford, Gari D; Saeed, Mohammed; Mark, Roger G

    2011-01-01

    The critical state of intensive care unit (ICU) patients demands close monitoring, and as a result a large volume of multi-parameter data is collected continuously. This represents a unique opportunity for researchers interested in clinical data mining. We sought to foster a more transparent and efficient intensive care research community by building a publicly available ICU database, namely Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II). The data harnessed in MIMIC-II were collected from the ICUs of Beth Israel Deaconess Medical Center from 2001 to 2008 and represent 26,870 adult hospital admissions (version 2.6). MIMIC-II consists of two major components: clinical data and physiological waveforms. The clinical data, which include patient demographics, intravenous medication drip rates, and laboratory test results, were organized into a relational database. The physiological waveforms, including 125 Hz signals recorded at bedside and corresponding vital signs, were stored in an open-source format. MIMIC-II data were also deidentified in order to remove protected health information. Any interested researcher can gain access to MIMIC-II free of charge after signing a data use agreement and completing human subjects training. MIMIC-II can support a wide variety of research studies, ranging from the development of clinical decision support algorithms to retrospective clinical studies. We anticipate that MIMIC-II will be an invaluable resource for intensive care research by stimulating fair comparisons among different studies.

  6. Sequestration of Cu(II), Ni(II), and Co(II) by ethyleneimine immobilized on silica

    International Nuclear Information System (INIS)

    Arakaki, Luiza N.H.; Alves, Ana Paula M.; Silva Filho, Edson C. da; Fonseca, Maria G.; Oliveira, Severino F.; Espinola, Jose Geraldo P.; Airoldi, Claudio

    2007-01-01

    Thermodynamic data on interaction of Cu(II), Ni(II), and Co(II) with silica modified with ethyleneimine are obtained by calorimetric titration. The amount of ethyleneimine anchored on silica surface was estimated to be 0.70 mmol g -1 . The enthalpies of binding Ni(II), Cu(II) and Co(II), are -3.59 ± 0.001, -4.88 ± 0.001, and -7.75 ± 0.003 kJ mol -1 , respectively

  7. International Seminar on Advanced Pulsed Neutron Sources PANS-II. Invited talks

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.

    1994-01-01

    A conceptual design of creating intense pulsed neutron sources based on high-current accelerators and pulsed reactors for neutron scattering experiments is considered. The progress in high-efficiency moderator developments is shown. Results of diffraction studied are presented

  8. Effective source approach to self-force calculations

    International Nuclear Information System (INIS)

    Vega, Ian; Wardell, Barry; Diener, Peter

    2011-01-01

    Numerical evaluation of the self-force on a point particle is made difficult by the use of delta functions as sources. Recent methods for self-force calculations avoid delta functions altogether, using instead a finite and extended 'effective source' for a point particle. We provide a review of the general principles underlying this strategy, using the specific example of a scalar point charge moving in a black hole spacetime. We also report on two new developments: (i) the construction and evaluation of an effective source for a scalar charge moving along a generic orbit of an arbitrary spacetime, and (ii) the successful implementation of hyperboloidal slicing that significantly improves on previous treatments of boundary conditions used for effective-source-based self-force calculations. Finally, we identify some of the key issues related to the effective source approach that will need to be addressed by future work.

  9. A CATALOG OF LOW-MASS STAR-FORMING CORES OBSERVED WITH SHARC-II AT 350 μ m

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, Akshaya; Arce, Héctor G. [Department of Astronomy, Yale University, P.O. Box 208101, New Haven, CT 06520 (United States); Dunham, Michael M.; Bourke, Tyler L. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS 78, Cambridge, MA 02138 (United States); II, Neal J. Evans [Department of Astronomy, The University of Texas at Austin, 2515 Speedway, Stop C1400, Austin, TX 78712-1205 (United States); Merello, Manuel [Istituto di Astrofisica e Planetologia Spaziali-INAF, Via Fosso del Cavaliere 100, I-00133 Roma (Italy); Wu, Jingwen, E-mail: mdunham@cfa.harvard.edu [National Astronomical Observatories, Chinese Academy of Sciences, 20A Datun Road, Chaoyang District, Beijing 100012 (China)

    2016-08-01

    We present a catalog of low-mass dense cores observed with the SHARC-II instrument at 350 μ m. Our observations have an effective angular resolution of 10″, approximately 2.5 times higher than observations at the same wavelength obtained with the Herschel Space Observatory , albeit with lower sensitivity, especially to extended emission. The catalog includes 81 maps covering a total of 164 detected sources. For each detected source, we tabulate basic source properties including position, peak intensity, flux density in fixed apertures, and radius. We examine the uncertainties in the pointing model applied to all SHARC-II data and conservatively find that the model corrections are good to within ∼3″, approximately 1/3 of the SHARC-II beam. We examine the differences between two array scan modes and find that the instrument calibration, beam size, and beam shape are similar between the two modes. We also show that the same flux densities are measured when sources are observed in the two different modes, indicating that there are no systematic effects introduced into our catalog by utilizing two different scan patterns during the course of taking observations. We find a detection rate of 95% for protostellar cores but only 45% for starless cores, and demonstrate the existence of a SHARC-II detection bias against all but the most massive and compact starless cores. Finally, we discuss the improvements in protostellar classification enabled by these 350  μ m observations.

  10. Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Celal [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Gundogdu, Ali [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Bulut, Volkan Numan [Department of Chemistry, Giresun Faculty of Art and Science, Karadeniz Technical University, 28049 Giresun (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: soylak@erciyes.edu.tr; Elci, Latif [Department of Chemistry, Faculty of Art and Science, Pamukkale University, 20020 Denizli (Turkey); Sentuerk, Hasan Basri [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Tuefekci, Mehmet [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-07-19

    A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L{sup -1} HNO{sub 3} in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 {mu}g L{sup -1}. The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

  11. Peripheral Codes in ASTRA for the TJ-II

    International Nuclear Information System (INIS)

    Lopez-Bruna, D.; Reynolds, J. M.; Cappa, A.; Martinell, J.; Garcia, J.; Gutierrez-Tapia, C.

    2010-01-01

    The study of data from the TJ-II device is often done with transport calculations based on the ASTRA transport system. However, complicated independent codes are used to obtain fundamental ingredients in these calculations, such as the particle and/or energy sources. These codes are accessible from ASTRA through the procedures explained in this report. (Author) 37 refs.

  12. Low-level radioactive waste source terms for the 1992 integrated data base

    International Nuclear Information System (INIS)

    Loghry, S.L.; Kibbey, A.H.; Godbee, H.W.; Icenhour, A.S.; DePaoli, S.M.

    1995-01-01

    This technical manual presents updated generic source terms (i.e., unitized amounts and radionuclide compositions) which have been developed for use in the Integrated Data Base (IDB) Program of the U.S. Department of Energy (DOE). These source terms were used in the IDB annual report, Integrated Data Base for 1992: Spent Fuel and Radioactive Waste Inventories, Projections, and Characteristics, DOE/RW-0006, Rev. 8, October 1992. They are useful as a basis for projecting future amounts (volume and radioactivity) of low-level radioactive waste (LLW) shipped for disposal at commercial burial grounds or sent for storage at DOE solid-waste sites. Commercial fuel cycle LLW categories include boiling-water reactor, pressurized-water reactor, fuel fabrication, and uranium hexafluoride (UF 6 ) conversion. Commercial nonfuel cycle LLW includes institutional/industrial (I/I) waste. The LLW from DOE operations is category as uranium/thorium fission product, induced activity, tritium, alpha, and open-quotes otherclose quotes. Fuel cycle commercial LLW source terms are normalized on the basis of net electrical output [MW(e)-year], except for UF 6 conversion, which is normalized on the basis of heavy metal requirement [metric tons of initial heavy metal ]. The nonfuel cycle commercial LLW source term is normalized on the basis of volume (cubic meters) and radioactivity (curies) for each subclass within the I/I category. The DOE LLW is normalized in a manner similar to that for commercial I/I waste. The revised source terms are based on the best available historical data through 1992

  13. Analysis of carbon transport in the EBR-II and FFTF primary sodium systems

    International Nuclear Information System (INIS)

    Snyder, R.B.; Natesan, K.; Kassner, T.F.

    1976-01-01

    An analysis of the carburization-decarburization behavior of austenitic stainless steels in the primary heat-transport systems of the EBR-II and FFTF has been made that is based upon a kinetic model for the diffusion process and the surface area of steel in contact with flowing sodium at various temperatures in the two systems. The analysis was performed for operating conditions that result in sodium outlet temperatures of 474 and 566 0 C in the FFTF and 470 0 C in the EBR-II. If there was no external source of carbon to the system, i.e., other than the carbon initially present in the steel and the sodium, the dynamic-equilibrium carbon concentrations calculated for the FFTF primary sodium were approximately 0.025 and approximately 0.065 ppm for the 474 and 566 0 C outlet temperatures, respectively, and approximately 0.018 ppm for the EBR-II primary system. The analysis indicated that a carbon-source rate of approximately 250 g/y would be required to increase the carbon concentration of the EBR-II sodium to the measured range of approximately 0.16--0.19 ppm. An evaluation of possible carbon sources and the amount of carbonaceous material introduced into the reactor cover gas and sodium suggests that the magnitude of the calculated contamination rate is reasonable. For a 566 0 C outlet temperature, carbonaceous material would have to be introduced into the FFTF primary system at a rate approximately 4--6 times higher than in EBR-II to achieve the same carbon concentration in the sodium in the two systems. Since contamination rates of approximately 1500 g/y are unlikely, high-temperature fuel cladding in the FFTF should exhibit decarburization similar to that observed in laboratory loop systems, in contrast to the minimal compositional changes that result after exposure of Type 316 stainless steel to EBR-II sodium at temperatures between approximately 625 and 650 0 C

  14. 40 CFR 74.47 - Transfer of allowances from the replacement of thermal energy-combustion sources.

    Science.gov (United States)

    2010-07-01

    ... replacement of thermal energy-combustion sources. 74.47 Section 74.47 Protection of Environment ENVIRONMENTAL...—combustion sources. (a) Thermal energy plan—(1) General provisions. The designated representative of an opt... quarter the replacement unit(s) will replace thermal energy of the opt-in source; (ii) The name...

  15. Characterization of radioactive orphan sources by gamma spectrometry

    International Nuclear Information System (INIS)

    Cruz W, H.

    2013-01-01

    The sealed radioactive sources are widely applicable in industry. They must have a permanent control and must be registered with the Technical Office of the National Authority (OTAN). However, at times it has identified the presence of abandoned sealed sources unknown to the owner. These sources are called 'orphan sources'. Of course these sources represent a high potential risk because accidents can trigger dire consequences depending on your activity and chemical form in which it presents the radioisotope. This paper describes the process and the actions taken to characterize two orphan radioactive sources from the smelter a Aceros Arequipa. For characterization we used a gamma spectrometry system using a detector NaI(Tl) 3″ x 3″ with a multichannel analyzer Nucleus PCA-II. The radioisotope identified was cesium - 137 ( 137 Cs) in both cases. Fortunately, the sources maintained their integrity would otherwise have generated significant pollution considering the chemical form of the radioisotope and easy dispersion. (author)

  16. 21-cm signature of the first sources in the Universe: prospects of detection with SKA

    Science.gov (United States)

    Ghara, Raghunath; Choudhury, T. Roy; Datta, Kanan K.

    2016-07-01

    Currently several low-frequency experiments are being planned to study the nature of the first stars using the redshifted 21-cm signal from the cosmic dawn and Epoch of Reionization. Using a one-dimensional radiative transfer code, we model the 21-cm signal pattern around the early sources for different source models, I.e. the metal-free Population III (PopIII) stars, primordial galaxies consisting of Population II (PopII) stars, mini-QSOs and high-mass X-ray binaries (HMXBs). We investigate the detectability of these sources by comparing the 21-cm visibility signal with the system noise appropriate for a telescope like the SKA1-low. Upon integrating the visibility around a typical source over all baselines and over a frequency interval of 16 MHz, we find that it will be possible to make a ˜9σ detection of the isolated sources like PopII galaxies, mini-QSOs and HMXBs at z ˜ 15 with the SKA1-low in 1000 h. The exact value of the signal-to-noise ratio (SNR) will depend on the source properties, in particular on the mass and age of the source and the escape fraction of ionizing photons. The predicted SNR decreases with increasing redshift. We provide simple scaling laws to estimate the SNR for different values of the parameters which characterize the source and the surrounding medium. We also argue that it will be possible to achieve an SNR ˜9 even in the presence of the astrophysical foregrounds by subtracting out the frequency-independent component of the observed signal. These calculations will be useful in planning 21-cm observations to detect the first sources.

  17. Heat transport properties of pressurized and saturated He II in the vicinity of T/sub λ

    International Nuclear Information System (INIS)

    Fouaidy, M.; Francois, M.X.

    1988-01-01

    A quantitative experimental analysis of He II confined to a channel has been performed for the heat flux densities and bulk temperatures for which the transitions of He II to He I, He II to vapor, and He II to He I to vapor could occur in the neighborhood of the heating source or in the channel itself. Temperature measurements of the heater and the He I and He II channel flow were used in a thermohydrodynamic model of the heat flow. Emphasis was given to the $lambda transition and thus to the case where a He I layer separated the heater from the He II channel. The dynamics of the vaporized He I and He II bubbles and their role in heat transfer are analyzed

  18. Angiotensin II stimulates superoxide production by nitric oxide synthase in thick ascending limbs.

    Science.gov (United States)

    Gonzalez-Vicente, Agustin; Saikumar, Jagannath H; Massey, Katherine J; Hong, Nancy J; Dominici, Fernando P; Carretero, Oscar A; Garvin, Jeffrey L

    2016-02-01

    Angiotensin II (Ang II) causes nitric oxide synthase (NOS) to become a source of superoxide (O2 (-)) via a protein kinase C (PKC)-dependent process in endothelial cells. Ang II stimulates both NO and O2 (-) production in thick ascending limbs. We hypothesized that Ang II causes O2 (-) production by NOS in thick ascending limbs via a PKC-dependent mechanism. NO production was measured in isolated rat thick ascending limbs using DAF-FM, whereas O2 (-) was measured in thick ascending limb suspensions using the lucigenin assay. Consistent stimulation of NO was observed with 1 nmol/L Ang II (P thick ascending limbs via a PKC- and NADPH oxidase-dependent process; and (2) the effect of Ang II is not due to limited substrate. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  19. THE HST/ACS COMA CLUSTER SURVEY. II. DATA DESCRIPTION AND SOURCE CATALOGS

    International Nuclear Information System (INIS)

    Hammer, Derek; Verdoes Kleijn, Gijs; Den Brok, Mark; Peletier, Reynier F.; Hoyos, Carlos; Balcells, Marc; Aguerri, Alfonso L.; Ferguson, Henry C.; Goudfrooij, Paul; Carter, David; Guzman, Rafael; Smith, Russell J.; Lucey, John R.; Graham, Alister W.; Trentham, Neil; Peng, Eric; Puzia, Thomas H.; Jogee, Shardha; Batcheldor, Dan; Bridges, Terry J.

    2010-01-01

    The Coma cluster, Abell 1656, was the target of an HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in early 2007, the partially completed survey still covers ∼50% of the core high-density region in Coma. Observations were performed for 25 fields that extend over a wide range of cluster-centric radii (∼1.75 Mpc or 1 0 ) with a total coverage area of 274 arcmin 2 . The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the southwest region of the cluster. In this paper, we present reprocessed images and SEXTRACTOR source catalogs for our survey fields, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SEXTRACTOR Kron magnitudes based only on the measured source flux and its half-light radius. We have performed photometry for ∼73,000 unique objects; approximately one-half of our detections are brighter than the 10σ point-source detection limit at F814W = 25.8 mag (AB). The slight majority of objects (60%) are unresolved or only marginally resolved by ACS. We estimate that Coma members are 5%-10% of all source detections, which consist of a large population of unresolved compact sources (primarily globular clusters but also ultra-compact dwarf galaxies) and a wide variety of extended galaxies from a cD galaxy to dwarf low surface brightness galaxies. The red sequence of Coma member galaxies has a color-magnitude relation with a constant slope and dispersion over 9 mag (-21 F814W < -13). The initial data release for the HST-ACS Coma Treasury program was made available to the public in 2008 August. The images and catalogs described

  20. Average [O II] nebular emission associated with Mg II absorbers: dependence on Fe II absorption

    Science.gov (United States)

    Joshi, Ravi; Srianand, Raghunathan; Petitjean, Patrick; Noterdaeme, Pasquier

    2018-05-01

    We investigate the effect of Fe II equivalent width (W2600) and fibre size on the average luminosity of [O II] λλ3727, 3729 nebular emission associated with Mg II absorbers (at 0.55 ≤ z ≤ 1.3) in the composite spectra of quasars obtained with 3 and 2 arcsec fibres in the Sloan Digital Sky Survey. We confirm the presence of strong correlations between [O II] luminosity (L_{[O II]}) and equivalent width (W2796) and redshift of Mg II absorbers. However, we show L_{[O II]} and average luminosity surface density suffer from fibre size effects. More importantly, for a given fibre size, the average L_{[O II]} strongly depends on the equivalent width of Fe II absorption lines and found to be higher for Mg II absorbers with R ≡W2600/W2796 ≥ 0.5. In fact, we show the observed strong correlations of L_{[O II]} with W2796 and z of Mg II absorbers are mainly driven by such systems. Direct [O II] detections also confirm the link between L_{[O II]} and R. Therefore, one has to pay attention to the fibre losses and dependence of redshift evolution of Mg II absorbers on W2600 before using them as a luminosity unbiased probe of global star formation rate density. We show that the [O II] nebular emission detected in the stacked spectrum is not dominated by few direct detections (i.e. detections ≥3σ significant level). On an average, the systems with R ≥ 0.5 and W2796 ≥ 2 Å are more reddened, showing colour excess E(B - V) ˜ 0.02, with respect to the systems with R < 0.5 and most likely trace the high H I column density systems.

  1. Cost reduction and safety design features of ABWR-II. Annex 5

    International Nuclear Information System (INIS)

    Koh, F.; Moriya, K.; Anegawa, T.

    2002-01-01

    The ABWR-II, which is aimed to be the next generation reactor following the latest BWR: Advanced Boiling Reactor (ABWR), is now under development jointly by the Japanese BWR utilities, General Electric Company, Hitachi Limited, and Toshiba Corporation. The key objectives of ABWR-II development include improvement in economics and further sophistication in safety for commercialization in the late 2010's and after. This paper summarizes the current status of ABWR-II development focusing on economics and safety. Plant power rating, fuel size, CRD rationalization and outage period are discussed from a cost reduction perspective. In terms of safety, the features such as diversification in emergency power sources and passive system application against severe accidents are being introduced. (author)

  2. LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Daly, Edward F. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); McGee, Michael W. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2018-04-01

    The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCM and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.

  3. Status of the LCLS-II undulators

    Energy Technology Data Exchange (ETDEWEB)

    Wallén, E., E-mail: ejwallen@lbl.gov; Arbelaez, D.; Brown, A.; Dougherty, J.; Corlett, J.; DeMello, A.; Hanzel, K.; Jung, J.-Y.; Leitner, M.; Madur, A.; McCombs, K.; Marks, S.; Munson, D.; Plate, D.; Pucci, J.; Ray, K.; Schlueter, R.; Mateo, E. San [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); D’Ewart, M.; Rowen, M. [SLAC National Accelerator Laboratory 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2016-07-27

    The new free electron laser facility Linear Coherent Light Source II (LCLS-II) under construction at SLAC National Accelerator Laboratory will use planar variable gap undulators of hybrid type for the production of free electron laser (FEL) radiation. The LCLS-II will include two FELs with two separate rows of undulators to generate soft and hard x-rays. The soft x-rays will be produced by undulators with 39 mm period length (SXR) and the hard x-rays will be produced by undulators with 26 mm period length (HXR). Both the SXR and the HXR undulators are 3.4 m long and they use a common support structure and frame. In total 21 SXR and 32 HXR undulators will be produced by Lawrence Berkeley National Laboratory in collaboration with SLAC National Accelerator Laboratory. A full-scale prototype with 32 mm period length, called HXU, has been assembled at Lawrence Berkeley National Laboratory (LBNL). The present status of the design, prototyping, and pre-series production of the SXR and HXR undulators are presented in this paper together with the first results from measurements on the full scale HXU prototype.

  4. Dietary Sources of High Sodium Intake in Turkey: SALTURK II

    Directory of Open Access Journals (Sweden)

    Yunus Erdem

    2017-08-01

    Full Text Available Previous research has shown daily salt intakes in Turkey to be far above the recommended limits. Knowing the sources of dietary salt could form a basis for preventive strategies aimed towards salt reduction. This study aimed to investigate dietary sources of salt in Turkey. A sub-group (n = 657 was selected from the PatenT2 study population, which represented the urban and rural areas of 4 major cities (Ankara, Istanbul, Izmir, and Konya. A questionnaire inquiring about sociodemographic characteristics, medical histories, detailed histories of diet, and salt consumption was completed. Participants were asked to collect a 24-h urine sample and to record their food intake (dietary recall on the same day. Of 925 participants selected, 657 (71% provided accurate 24-h urine collections, based on creatinine excretion data. The mean daily 24-h urinary sodium excretion was 252.0 ± 92.2 mmol/day, equal to daily salt intake of 14.8 ± 5.4 g. Of the 657 participants with accurate 24-h urine collections, 464 (70% provided fully completed dietary recalls. Among these 464 participants, there was a significant difference between the 24-h urinary sodium excretion-based salt intake estimation (14.5 ± 5.1 g/day and the dietary recall-based salt intake estimation (12.0 ± 7.0 g/day (p < 0.001. On the other hand, a positive correlation was obtained between the dietary recall-based daily salt intake and 24-h urinary sodium excretion-based daily salt intake (r = 0.277, p < 0.001. Bread was the main source of salt (34% followed by salt added during cooking and preparing food before serving (30%, salt from various processed foods (21%, and salt added at the table during food consumption (11%. Conclusively, this study confirmed a very high salt intake of the adult population in four major cities in Turkey. The present findings support the emerging salt reduction strategy in Turkey by promoting lower salt content in baked bread, and less salt use in habitual food

  5. Structural information on the coordination compounds formed by manganese(II), cobalt(II), nickel(II), zinc(II), cadmium(II) and mercury(II) thiocyanates with 4-cyanopyridine N-oxide from their magnetic moments, electronic and infrared spectra

    Science.gov (United States)

    Ahuja, I. S.; Yadava, C. L.; Singh, Raghuvir

    1982-05-01

    Coordination compounds formed by the interaction of 4-cyanopyridine. N-oxide (4-CPO), a potentially bidentate ligand, with manganese(II), cobalt(II), nickel(II), zinc(II), cadmium(II) and rnercury(II) thiocyanates have been prepared and characterized from their elemental analyses, magnetic susceptibilities, electronic and infrared spectral studies down to 200 cm -1 in the solid state. The compounds isolated are: Mn(4-CPO) 2(NCS) 2, Co(4-CPO) 2(NCS) 2,Ni(4-CPO) 2(NCS) 2,Zn(4-CPO) 2(NCS) 2, Cd(4-CPO)(NCS) 2 and Hg(4-CPO) 2(SCN) 2. It is shown that 4-CPO acts as a terminal N-oxide oxygen bonded monodentate ligand in all the metal(II) thiocyanate complexes studied. Tentative stereochemistries of the complexes in the solid state are discussed. The ligand field parameters 10 Dq, B, β and λ calculated for the manganese(II), cobalt(II) and nickel(II) complexes are consistent with their proposed stereochemistries.

  6. Macrocyclic receptor showing extremely high Sr(II)/Ca(II) and Pb(II)/Ca(II) selectivities with potential application in chelation treatment of metal intoxication.

    Science.gov (United States)

    Ferreirós-Martínez, Raquel; Esteban-Gómez, David; Tóth, Éva; de Blas, Andrés; Platas-Iglesias, Carlos; Rodríguez-Blas, Teresa

    2011-04-18

    Herein we report a detailed investigation of the complexation properties of the macrocyclic decadentate receptor N,N'-Bis[(6-carboxy-2-pyridil)methyl]-4,13-diaza-18-crown-6 (H(2)bp18c6) toward different divalent metal ions [Zn(II), Cd(II), Pb(II), Sr(II), and Ca(II)] in aqueous solution. We have found that this ligand is especially suited for the complexation of large metal ions such as Sr(II) and Pb(II), which results in very high Pb(II)/Ca(II) and Pb(II)/Zn(II) selectivities (in fact, higher than those found for ligands widely used for the treatment of lead poisoning such as ethylenediaminetetraacetic acid (edta)), as well as in the highest Sr(II)/Ca(II) selectivity reported so far. These results have been rationalized on the basis of the structure of the complexes. X-ray crystal diffraction, (1)H and (13)C NMR spectroscopy, as well as theoretical calculations at the density functional theory (B3LYP) level have been performed. Our results indicate that for large metal ions such as Pb(II) and Sr(II) the most stable conformation is Δ(δλδ)(δλδ), while for Ca(II) our calculations predict the Δ(λδλ)(λδλ) form being the most stable one. The selectivity that bp18c6(2-) shows for Sr(II) over Ca(II) can be attributed to a better fit between the large Sr(II) ions and the relatively large crown fragment of the ligand. The X-ray crystal structure of the Pb(II) complex shows that the Δ(δλδ)(δλδ) conformation observed in solution is also maintained in the solid state. The Pb(II) ion is endocyclically coordinated, being directly bound to the 10 donor atoms of the ligand. The bond distances to the donor atoms of the pendant arms (2.55-2.60 Å) are substantially shorter than those between the metal ion and the donor atoms of the crown moiety (2.92-3.04 Å). This is a typical situation observed for the so-called hemidirected compounds, in which the Pb(II) lone pair is stereochemically active. The X-ray structures of the Zn(II) and Cd(II) complexes show that

  7. Pioneering SESAME light source officially opened

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    Allan, Jordan, 16 May 2017. The SESAME light source was today officially opened by His Majesty King Abdullah II. An intergovernmental organization, SESAME is the first regional laboratory for the Middle East and neighbouring regions The laboratory’s official opening ushers in a new era of research covering fields ranging from medicine and biology, through materials science, physics and chemistry to healthcare, the environment, agriculture and archaeology.

  8. Optimizing the injection straight of PEP II asymmetric B Factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.; Ronan, M.

    1992-04-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  9. Optimizing the injection straight of PEP II asymmetric B factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.

    1992-01-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  10. Solid Phase Extraction of Trace Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) Ions in Beverages on Functionalized Polymer Microspheres Prior to Flame Atomic Absorption Spectrometric Determinations.

    Science.gov (United States)

    Berber, Hale; Alpdogan, Güzin

    2017-01-01

    In this study, poly(glycidyl methacrylate-methyl methacrylate-divinylbenzene) was synthesized in the form of microspheres, and then functionalized by 2-aminobenzothiazole ligand. The sorption properties of these functionalized microspheres were investigated for separation, preconcentration and determination of Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) ions using flame atomic absorption spectrometry. The optimum pH values for quantitative sorption were 2 - 4, 5 - 8, 6 - 8, 4 - 6, 2 - 6 and 2 - 3 for Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II), respectively, and also the highest sorption capacity of the functionalized microspheres was found to be for Cu(II) with the value of 1.87 mmol g -1 . The detection limits (3σ; N = 6) obtained for the studied metals in the optimal conditions were observed in the range of 0.26 - 2.20 μg L -1 . The proposed method was successfully applied to different beverage samples for the determination of Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) ions, with the relative standard deviation of <3.7%.

  11. 139 the impact of the national fadama ii development project

    African Journals Online (AJOL)

    OLUWOLE AKINNAGBE

    Key words: Impact, National Fadama II Facility, Poverty Alleviation, Agricultural ... production but enhance the income of the ... of employment has the higher incidence of ... This widening gap between ... each group (i.e. those earning ... Source: Field Survey data, 2007 .... increased as evidence has shown that the level.

  12. Turbulence in extended synchrotron radio sources. I. Polarization of turbulent sources. II. Power-spectral analysis

    International Nuclear Information System (INIS)

    Eilek, J.A.

    1989-01-01

    Recent theories of magnetohydrodynamic turbulence are used to construct microphysical turbulence models, with emphasis on models of anisotropic turbulence. These models have been applied to the determination of the emergent polarization from a resolved uniform source. It is found that depolarization alone is not a unique measure of the turbulence, and that the turblence will also affect the total-intensity distributions. Fluctuations in the intensity image can thus be employed to measure turbulence strength. In the second part, it is demonstrated that a power-spectral analysis of the total and polarized intensity images can be used to obtain the power spectra of the synchrotron emission. 81 refs

  13. Study of X-ray and gamma ray sources observed by the SIGNE (Prognoz 6 Satellite) experiment in the regions of the galactic center and anticenter

    International Nuclear Information System (INIS)

    Violes, F.

    1981-12-01

    Characteristics of the SIGNE II MP 6 experiment are reported and procedures to obtain the fluxes detected from all the sources are described. We next present deconvolution method used to isolate the galactic center sources. In the last chapter we present and discuss the photon spectra of the sources observed by the SIGNE II MP 6 experiment [fr

  14. On the Nature of Orion Source I

    Science.gov (United States)

    Báez-Rubio, A.; Jiménez-Serra, I.; Martín-Pintado, J.; Zhang, Q.; Curiel, S.

    2018-01-01

    The Kleinmann–Low nebula in Orion, the closest region of massive star formation, harbors Source I, whose nature is under debate. Knowledge of this source may have profound implications for our understanding of the energetics of the hot core in Orion KL since it might be the main heating source in the region. The spectral energy distribution of this source in the radio is characterized by a positive spectral index close to 2, which is consistent with (i) thermal bremsstrahlung emission of ionized hydrogen gas produced by a central massive protostar, or (ii) photospheric bremsstrahlung emission produced by electrons when deflected by the interaction with neutral and molecular hydrogen like Mira-like variable stars. If ionized hydrogen gas were responsible for the observed continuum emission, its modeling would predict detectable emission from hydrogen radio recombination lines (RRLs). However, our SMA observations were obtained with a high enough sensitivity to rule out that the radio continuum emission arises from a dense hypercompact H II region because the H26α line would have been detected, in contrast with our observations. To explain the observational constraints, we investigate further the nature of the radio continuum emission from source I. We have compared available radio continuum data with the predictions from our upgraded non-LTE 3D radiative transfer model, MOdel for REcombination LInes, to show that radio continuum fluxes and sizes can only be reproduced by assuming both dust and bremsstrahlung emission from neutral gas. The dust emission contribution is significant at ν ≥ 43 GHz. In addition, our RRL peak intensity predictions for the ionized metals case are consistent with the nondetection of Na and K RRLs at millimeter and submillimeter wavelengths.

  15. Shielding NSLS-II light source: Importance of geometry for calculating radiation levels from beam losses [Shielding Synchrotron Light Sources: Importance of geometry for calculating radiation levels from beam losses

    International Nuclear Information System (INIS)

    Kramer, S. L.; Ghosh, V. J.; Breitfeller, M.; Wahl, W.

    2016-01-01

    Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produces significantly higher neutron component dose to the experimental floor than a lower energy beam injection and ramped operations. Minimizing this dose will require adequate knowledge of where the miss-steered beam can occur and sufficient EM shielding close to the loss point, in order to attenuate the energy of the particles in the EM shower below the neutron production threshold (<10 MeV), which will spread the incident energy on the bulk shield walls and thereby the dose penetrating the shield walls. Designing supplemental shielding near the loss point using the analytic shielding model is shown to be inadequate because of its lack of geometry specification for the EM shower process. To predict the dose rates outside the tunnel requires detailed description of the geometry and materials that the beam losses will encounter inside the tunnel. Modern radiation shielding Monte-Carlo codes, like FLUKA, can handle this geometric description of the radiation transport process in sufficient detail, allowing accurate predictions of the dose rates expected and the ability to show weaknesses in the design before a high radiation incident occurs. The effort required to adequately define the accelerator geometry for these codes has been greatly reduced with the implementation of the graphical interface of FLAIR to FLUKA. This made the effective shielding process for NSLS-II quite accurate and reliable. Lastly, the principles used to provide

  16. Observations of Radical Precursors during TexAQS II: Findings and Implications

    Science.gov (United States)

    Olaguer, E. P.; Lefer, B. L.; Rappenglueck, B.; Pinto, J. P.

    2009-12-01

    The Texas Environmental Research Consortium (TERC) sponsored and helped organize significant components of the Second Texas Air Quality Study (TexAQS II). Some of the TERC-sponsored experiments, most notably those associated with the TexAQS II Radical and Aerosol Measurement Project (TRAMP) sited on top of the Moody Tower at the University of Houston, found evidence for the importance of short-lived radical sources such as formaldehyde (HCHO) and nitrous acid (HONO) in increasing ozone productivity. During TRAMP, daytime HCHO pulses as large as 32 ppb were observed and attributed to industrial activities upwind in the Houston Ship Channel (HSC), and HCHO peaks as large as 52 ppb were detected by in-situ surface monitors in the HSC. In addition, an instrumented Piper Aztec aircraft observed plumes of apparent primary formaldehyde in flares from petrochemical facilities in the HSC. In one such combustion plume, depleted of ozone by large NOx emissions, the Piper Aztec measured an HCHO-to-CO ratio three times that of mobile sources. HCHO from uncounted primary sources or ozonolysis of underestimated olefin emissions could significantly increase ozone productivity in Houston beyond previous expectations. Simulations with the CAMx model show that additional emissions of HCHO from industrial flares can increase peak ozone in Houston by up to 30 ppb, depending on conditions in the planetary boundary layer. Other findings from TexAQS II include significant concentrations of HONO throughout the day, well in excess of current air quality model predictions, with large nocturnal vertical gradients indicating a surface or near-surface source of HONO, and large concentrations of night-time radicals (~30 ppt HO2). Additional HONO sources could increase daytime ozone by more than 10 ppb. Improving the representation of primary and secondary HCHO and HONO in air quality models could enhance the effectiveness of simulated control strategies, and thus make ozone attainment

  17. Process simulations for the LCLS-II cryogenic systems

    Science.gov (United States)

    Ravindranath, V.; Bai, H.; Heloin, V.; Fauve, E.; Pflueckhahn, D.; Peterson, T.; Arenius, D.; Bevins, M.; Scanlon, C.; Than, R.; Hays, G.; Ross, M.

    2017-12-01

    Linac Coherent Light Source II (LCLS-II), a 4 GeV continuous-wave (CW) superconducting electron linear accelerator, is to be constructed in the existing two mile Linac facility at the SLAC National Accelerator Laboratory. The first light from the new facility is scheduled to be in 2020. The LCLS-II Linac consists of thirty-five 1.3 GHz and two 3.9 GHz superconducting cryomodules. The Linac cryomodules require cryogenic cooling for the super-conducting niobium cavities at 2.0 K, low temperature thermal intercept at 5.5-7.5 K, and a thermal shield at 35-55 K. The equivalent 4.5 K refrigeration capacity needed for the Linac operations range from a minimum of 11 kW to a maximum of 24 kW. Two cryogenic plants with 18 kW of equivalent 4.5 K refrigeration capacity will be used for supporting the Linac cryogenic cooling requirements. The cryogenic plants are based on the Jefferson Lab’s CHL-II cryogenic plant design which uses the “Floating Pressure” design to support a wide variation in the cooling load. In this paper, the cryogenic process for the integrated LCLS-II cryogenic system and the process simulation for a 4.5 K cryoplant in combination with a 2 K cold compressor box, and the Linac cryomodules are described.

  18. Helium cryosystem for the X-ray laser LCLS-II; Heliumkryosystem fuer den Roentgenlaser LCLS-II

    Energy Technology Data Exchange (ETDEWEB)

    Pflueckhahn, Dirk; Fauve, Eric; Heloin, Vincent; Ravindranath, Viswanath; Ross, Marc [SLAC National Accelerator Laboratory, Menlo Park, CA (United States)

    2017-07-01

    The Linac Coherent Light Source-II project represents the expansion of the LCLS free-electron laser, which has been successfully operated at the SLAC National Accelerator Laboratory since 2009. In collaboration with several national institutes, 37 cryomodules with superconducting accelerator cavities will be installed in a 700 m long section of the existing tunnel. The use of superconducting accelerator technology will enable particle energy of up to 4 GeV in CW (continuous wave) operation. Two identical cryogenic systems with an equivalent output of 18 kW each at 4.5 K are described below. The plants supply the linear accelerator with helium at several temperature levels. Superfluid helium II provides the cooling necessary to maintain superconductivity in the cavities. The operating temperature of the 1.3 GHz cavities has been set at 2 K. Two further helium circuits are used for shield cooling at approx. 35 K and cooling of heat loads at 5 K level. The purely dynamic compression of the cold helium vapour is a technical feature of the systems described here. In a five-stage chain of cold compressors of 32 mbar at the cavities, it is absolutely compressed to the suction pressure of the circulation compressors at approx. 1 bar. [German] Das Linac Coherent Light Source-II Projekt stellt die Erweiterung des seit 2009 erfolgreich betriebenen Freie- Elektronen-Lasers LCLS am SLAC National Accelerator Laboratory dar. In Kollaboration mit mehreren nationalen Instituten werden in einem 700 m langen Teilstueck des bereits bestehenden Tunnels 37 Kryomodule mit supraleitenden Beschleunigerkavitaeten installiert. Der Einsatz von supraleitender Beschleunigertechnologie wird eine Teilchenenergie von bis zu 4 GeV im CW (continous wave) Betrieb ermoeglichen. Zwei identische Kryoanlagen mit einer aequivalenten Leistung von je 18 kW bei 4,5 K werden im Folgenden beschrieben. Die Anlagen versorgen den Linearbeschleuniger mit Helium auf mehreren Temperaturniveaus. Superfluides Helium

  19. Electroforming copper targets for RTNS-II

    International Nuclear Information System (INIS)

    Kelley, W.K.; Dini, J.W.; Logan, C.M.

    1981-01-01

    Copper targets used in RTNS II, which is the world's most intense 14-MeV neutron source, contain water cooling channels for temperature control. There are two methods for fabricating these targets: (1) diffusion bonding a copper panel containing photoetched channels to another copper panel, and (2) an electroforming technique which involves filling the photoetched channels with wax, plating thick copper to seal over the channels and then removing the wax. Development of this latter process and results obtained with it are described

  20. A Portable Source of Lattice-Trapped and Ultracold Strontium (PLUS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate the portable source of lattice-trapped, ultracold strontium (PLUS) designed during Phase I. The device uses simplified and robust...

  1. Characterization of selenium in ambient aerosols and primary emission sources.

    Science.gov (United States)

    De Santiago, Arlette; Longo, Amelia F; Ingall, Ellery D; Diaz, Julia M; King, Laura E; Lai, Barry; Weber, Rodney J; Russell, Armistead G; Oakes, Michelle

    2014-08-19

    Atmospheric selenium (Se) in aerosols was investigated using X-ray absorption near-edge structure (XANES) spectroscopy and X-ray fluorescence (XRF) microscopy. These techniques were used to determine the oxidation state and elemental associations of Se in common primary emission sources and ambient aerosols collected from the greater Atlanta area. In the majority of ambient aerosol and primary emission source samples, the spectroscopic patterns as well as the absence of elemental correlations suggest Se is in an elemental, organic, or oxide form. XRF microscopy revealed numerous Se-rich particles, or hotspots, accounting on average for ∼16% of the total Se in ambient aerosols. Hotspots contained primarily Se(0)/Se(-II). However, larger, bulk spectroscopic characterizations revealed Se(IV) as the dominant oxidation state in ambient aerosol, followed by Se(0)/Se(-II) and Se(VI). Se(IV) was the only observed oxidation state in gasoline, diesel, and coal fly ash, while biomass burning contained a combination of Se(0)/Se(-II) and Se(IV). Although the majority of Se in aerosols was in the most toxic form, the Se concentration is well below the California Environmental Protection Agency chronic exposure limit (∼20000 ng/m(3)).

  2. Commissioning of NSLS-II

    Energy Technology Data Exchange (ETDEWEB)

    Willeke, F.

    2015-05-03

    NSLS-II, the new 3rd generation light source at BNL was designed for a brightness of 1022 photons s-1mm-2mrad-2 (0.1%BW)-1. It was constructed between 2009 and 2014. The storage ring was commissioned in April 2014 which was followed by insertion device and beamline commissioning in the fall of 2014. All ambitious design parameters of the facility have already been achieved except for commissioning the full beam intensity of 500mA which requires more RF installation. This paper reports on the results of commissioning.

  3. Physical chemistry II essentials

    CERN Document Server

    REA, The Editors of

    1992-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Physical Chemistry II includes reaction mechanisms, theoretical approaches to chemical kinetics, gravitational work, electrical and magnetic work, surface work, kinetic theory, collisional and transport properties of gases, statistical mechanics, matter and waves, quantum mechanics, and rotations and vibrations of atoms and molecules.

  4. Optimization study for Pb(II) and COD sequestration by consortium of sulphate-reducing bacteria

    Science.gov (United States)

    Verma, Anamika; Bishnoi, Narsi R.; Gupta, Asha

    2017-09-01

    In this study, initial minimum inhibitory concentration (MIC) of Pb(II) ions was analysed to check optimum concentration of Pb(II) ions at which the growth of sulphate-reducing consortium (SRC) was found to be maximum. 80 ppm of Pb(II) ions was investigated as minimum inhibitory concentration for SRC. Influence of electron donors such as lactose, sucrose, glucose and sodium lactate was examined to investigate best carbon source for growth and activity of sulphate-reducing bacteria. Sodium lactate was found to be the prime carbon source for SRC. Later optimization of various parameters was executed using Box-Behnken design model of response surface methodology to explore the effectiveness of three independent operating variables, namely, pH (5.0-9.0), temperature (32-42 °C) and time (5.0-9.0 days), on dependent variables, i.e. protein content, precipitation of Pb(II) ions, and removal of COD by SRC biomass. Maximum removal of COD and Pb(II) was observed to be 91 and 98 %, respectively, at pH 7.0 and temperature 37 °C and incubation time 7 days. According to response surface analysis and analysis of variance, the experimental data were perfectly fitted to the quadratic model, and the interactive influence of pH, temperature and time on Pb(II) and COD removal was highly significant. A high regression coefficient between the variables and response ( r 2 = 0.9974) corroborate eminent evaluation of experimental data by second-order polynomial regression model. SEM and Fourier transform infrared analysis was performed to investigate morphology of PbS precipitates, sorption mechanism and involved functional groups in metal-free and metal-loaded biomass of SRC for Pb(II) binding.

  5. Feasibility of non-linear simulation for Field II using an angular spectrum approach

    DEFF Research Database (Denmark)

    Du, Yigang; Jensen, Jørgen Arendt

    2008-01-01

    this procedure is to find the accuracy of the approach for linear propagation, where the result can be validated using Field II simulations. The ASA calculations are carried out by 3D fast Fourier transform using Matlab, where lambda=2 is chosen as the spatial sampling rate to reduce aliasing errors. Zero......-padding is applied to enlarge the source plane to a (4N - 1) times (4N - 1) matrix to overcome artifacts in terms of the circular convolution. The source plane covering an area of 9 times 9 mm2 with N = 61 samples along both side, is 0.05 mm away from a 5 MHz planar piston transducer, which is simulated by Field II....... To determine the accuracy, different sampling intervals and zero-paddings are compared and the errors are calculated with Field II as a reference. It can be seen that zero-padding with 4N - 1 and lambda=2 sampling can both reduce the errors from 25.7% to 12.9% for the near-field and from 18.1% to 5...

  6. The History of MIS-Y: U.S. Strategic Interrogation During World War II

    National Research Council Canada - National Science Library

    Kleinman, Steven M

    2002-01-01

    As World War II unfolded, the strategic interrogation programs established by the British, German, and American forces evolved into robust collection entities that proved to be a unique source of critical intelligence...

  7. Synthesis, characterization and thermal studies of nickel (II), copper (II), zinc (II) and cadmium (II) complexes with some mixed ligands

    International Nuclear Information System (INIS)

    Mitra, Samiran; Kundu, Parimal; Singh, Rajkumar Bhubon

    1998-01-01

    Dichloro-(DCA) and trichloroacetate(TCA) -cyclic ligand morpholine (Morph)/thiomorpholine (Tmorph)/methylmorpholine (Mmorph)/dimethyl-piperazine (DMP) complexes of nickel (II), copper (II), zinc (II) and cadmium (II) with the compositions [Ni(tmorph) 2 (DCA) 2 ], [Ni(tmorph) 2 (TCA) 2 ].2H 2 O, [Cu(DMP) 2 (TCA) 2 ],[ML 2 X 2 ].nH 2 O where M=Zn II or Cd II , L=Morph, DMP or tmorph and X=DCA or TCA and n=O except in case of [Cd (Morph) 2 (TCA) 2 ] where n=1 have been synthesised. Some intermediate complexes have been isolated by temperature arrest technique (pyrolysis) and characterised. Configurational and conformational changes have been studied by elemental analyses, IR and electronic spectra, magnetic moment data (in the case of Ni(II) and Cu(II) complexes) and thermal analysis. E a * , ΔH, and ΔS for the decomposition reaction of these complexes are evaluated and the stability of the complexes with respect to activation energy has also been compared. The linear correlation has been found between E a * and ΔS for the decomposition of the complexes. (author)

  8. A two-point diagnostic for the H II galaxy Hubble diagram

    Science.gov (United States)

    Leaf, Kyle; Melia, Fulvio

    2018-03-01

    A previous analysis of starburst-dominated H II galaxies and H II regions has demonstrated a statistically significant preference for the Friedmann-Robertson-Walker cosmology with zero active mass, known as the Rh = ct universe, over Λcold dark matter (ΛCDM) and its related dark-matter parametrizations. In this paper, we employ a two-point diagnostic with these data to present a complementary statistical comparison of Rh = ct with Planck ΛCDM. Our two-point diagnostic compares, in a pairwise fashion, the difference between the distance modulus measured at two redshifts with that predicted by each cosmology. Our results support the conclusion drawn by a previous comparative analysis demonstrating that Rh = ct is statistically preferred over Planck ΛCDM. But we also find that the reported errors in the H II measurements may not be purely Gaussian, perhaps due to a partial contamination by non-Gaussian systematic effects. The use of H II galaxies and H II regions as standard candles may be improved even further with a better handling of the systematics in these sources.

  9. μC/OS-II the real-time kennel and its new progress

    International Nuclear Information System (INIS)

    Shao Beibei

    2003-01-01

    A lot of effort has been made to spread the application of RTOS in embedded system development in China. RTOS, μC/OS and μC/OS-II, with its opened source code, is well known in embedded systems. Learning RTOS, Using RTOS, becomes more and more popular. The Book of 'Micro C/OS-II The Real-Time Kennel Second Edition' was published in 2002. Here some new progress of the RTOS, especially the safety certifications, the reliability of software is introduced. (authors)

  10. Competition from Cu(II), Zn(II) and Cd(II) in Pb(II) binding to Suwannee River Fulvic Acid

    NARCIS (Netherlands)

    Chakraborty, P.; Chakrabarti, C.L.

    2008-01-01

    This is a study of trace metal competition in the complexation of Pb(II) by well-characterized humic substances, namely Suwannee River Fulvic Acid (SRFA) in model solutions. It was found that Cu(II) seems to compete with Pb(II) for strong binding sites of SRFA when present at the same concentration

  11. Three Bright X-ray Sources in NGC 1313

    Science.gov (United States)

    Colbert, E.; Petre, R.; Schlegel, E.

    1992-12-01

    Three bright X-ray sources were detected in a recent (April/May 1991) ROSAT PSPC observation of the nearby (D ~ 4.5 Mpc) face--on barred spiral galaxy NGC 1313. Two of the sources were at positions coincident with X-ray sources detected by Fabbiano & Trinchieri (ApJ 315, 1987) in a previous (Jan 1980) Einstein IPC observation. The position of the brightest Einstein source is near the center of NGC 1313, and the second Einstein source is ~ 7' south of the ``nuclear'' source, in the outskirts of the spiral arms. A third bright X-ray source was detected in the ROSAT observation ~ 7' southwest of the ``nuclear'' source. We present X-ray spectra and X-ray images for the three bright sources found in the ROSAT observation of NGC 1313, and compare with previous Einstein results. Spectral analysis of these sources require them to have very large soft X-ray luminosities ( ~ 10(40) erg s(-1) ) when compared with typical X-ray sources in our Galaxy. Feasible explanations for the X-ray emission are presented. The third X-ray source is positively identified with the recently discovered (Ryder et. al., ApJ 1992) peculiar type-II supernova 1978K.

  12. Synthesis, investigation and spectroscopic characterization of piroxicam ternary complexes of Fe(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with glycine and DL-phenylalanine

    Science.gov (United States)

    Mohamed, Gehad G.; El-Gamel, Nadia E. A.

    2004-11-01

    The ternary piroxicam (Pir; 4-hydroxy-2-methyl- N-(2-pyridyl)-2H-1,2-benzothiazine-3-carboxamide 1,1-dioxide) complexes of Fe(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with various amino acids (AA) such as glycine (Gly) or DL-phenylalanine (PhA) were prepared and characterized by elemental analyses, molar conductance, IR, UV-Vis, magnetic moment, diffuse reflectance and X-ray powder diffraction. The UV-Vis spectra of Pir and the effect of metal chelation on the different interligand transitions are discussed in detailed manner. IR and UV-Vis spectra confirm that Pir behaves as a neutral bidentate ligand coordinated to the metal ions via the pyridine- N and carbonyl group of the amide moiety. Gly molecule acted as a uninegatively monodentate ligand and coordinate to the metal ions through its carboxylic group, in addition PhA acted as a uninegatively bidentate ligand and coordinate to the metal ions through its carboxylic and amino groups. All the chelates have octahedral geometrical structures while Cu(II)- and Zn(II)-ternary chelates with PhA have square planar geometrical structures. The molar conductance data reveal that most of these chelates are non electrolytes, while Fe(III)-Pir-Gly, Co(II)-, Ni(II)-, Cu(II)- and Zn(II)-Pir-PhA cheletes were 1:1 electrolytes. X-ray powder diffraction is used as a new tool to estimate the crystallinity of chelates as well as to elucidate their geometrical structures.

  13. Ultrahigh-energy Cosmic Rays from Fanaroff Riley class II radio galaxies

    Science.gov (United States)

    Rachen, Joerg; Biermann, Peter L.

    1992-08-01

    The hot spots of very powerful radio galaxies (Fanaroff Riley class II) are argued to be the sources of the ultrahigh energy component in Cosmic Rays. We present calculations of Cosmic Ray transport in an evolving universe, taking the losses against the microwave background properly into account. As input we use the models for the cosmological radio source evolution derived by radioastronomers (mainly Peacock 1985). The model we adopt for the acceleration in the radio hot spots has been introduced by Biermann and Strittmatter (1987), and Meisenheimer et al. (1989) and is based on first order Fermi theory of particle acceleration at shocks (see, e.g., Drury 1983). As an unknown the actual proportion of energy density in protons enters, which together with structural uncertainties in the hot spots should introduce no more than one order of magnitude in uncertainty: We easily reproduce the observed spectra of high energy cosmic rays. It follows that scattering of charged energetic particles in intergalactic space must be sufficiently small in order to obtain contributions from sources as far away as even the nearest Fanaroff Riley class II radio galaxies. This implies a strong constraint on the turbulent magnetic field in intergalactic space.

  14. Coordination compounds of cobalt(II), nickel(II), copper(II), and zinc(II) with pantothenic acid

    Energy Technology Data Exchange (ETDEWEB)

    Shabilalov, A.A.; Yunuskhodzhaev, A.N.; Khodzhaev, O.F.; Azizov, M.A.

    1986-11-01

    The compounds Ni(PANA - H)/sub 2/ x 4H/sub 2/O (PANA stands for pantothenic acid, and - H indicates a deprotonated ligand), Cu(PANA - H)/sub 2/ x 2H/sub 2/O, Zn(PANA - H)/sub 2/ x H/sub 2/O, Co(PANA - H)Cl x H/sub 2/O, and Ni(PANA - H)Cl x 3H/sub 2/O have been synthesized on the basis of pantothenic acid and Co(II), Ni(II), Cu(II), and Zn(II) salts in aqueous media. The compounds have been identified by elemental and x-ray diffraction analysis. Some physicochemical properties (solubility, melting point, molar conductivity) of the compounds obtained have been studied. The structure of the compounds isolated has been established on the basis of an analysis of their IR, ESR, and electronic spectra, as well as derivatograms.

  15. Heat flow in a He II filled fin

    International Nuclear Information System (INIS)

    Warren, R.P.

    1984-01-01

    This chapter demonstrates the influence of diameter, length, Kapitza conductance and temperature on the heat carrying capacity of an externally cooled, circular He II filled channel with zero net mass flow and of negligible wall thermal resistance. Topics considered include the internal convection mechanism and the heat transfer model (boundary conditions, solution procedure). The large apparent thermal conductivity of He-II is explained by the two fluid model as an internal convection in which there is a counter flow of the normal and superfluids with no net mass flow. A separate bath is considered in which an He-IIp (pressurized superfluid helium) filled fin is immersed which extends from the heated reservoir. A single heat sink can serve multiple heat sources

  16. What Are “X-shaped” Radio Sources Telling Us? II. Properties of a Sample of 87

    Science.gov (United States)

    Saripalli, Lakshmi; Roberts, David H.

    2018-01-01

    In an earlier paper, we presented Jansky Very Large Array multi-frequency, multi-array continuum imaging of a unique sample of low-axial ratio radio galaxies. In this paper, the second in the series, we examine the images to learn the phenomenology of how the off-axis emission relates to the main radio source. Inversion-symmetric offset emission appears to be bimodal and to originate from one of two strategic locations: outer ends of radio lobes (outer-deviation) or from inner ends (inner-deviation). The latter sources are almost always associated with edge-brightened sources. With S- and Z-shaped sources being a subset of outer-deviation sources, this class lends itself naturally to explanations involving black hole axis precession. Our data allow us to present a plausible model for the more enigmatic inner-deviation sources with impressive wings; as for outer-deviation sources these too require black hole axis shifts, although they also require plasma backflows into relic channels. Evolution in morphology over time relates the variety in structures in inner-deviation sources including XRGs. With features such as non-collinearities, central inner-S “spine,” corresponding lobe emission peaks, double and protruding hotspots not uncommon, black hole axis precession, drifts, or flips could be active in a significant fraction of radio sources with prominent off-axis emission. At least 4% of radio galaxies appear to undergo black hole axis rotation. Quasars offer a key signature for recognizing rotating axes. With a rich haul of sources that have likely undergone axis rotation, our work shows the usefulness of low-axial ratio sources in pursuing searches for binary supermassive black holes.

  17. Spectroscopic and thermal degradation behavior of Mg(II), Ca(II), Ba(II) and Sr(II) complexes with paracetamol drug

    OpenAIRE

    Moamen S. Refat; Gehad G. Mohamed; Mohamed Y. El-Sayed; Hamada M.A. Killa; Hammad Fetooh

    2017-01-01

    Complexes of Mg(II), Ca(II), Ba(II) and Sr(II) with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical dat...

  18. The HST/ACS Coma Cluster Survey. II. Data Description and Source Catalogs

    Science.gov (United States)

    Hammer, Derek; Kleijn, Gijs Verdoes; Hoyos, Carlos; Den Brok, Mark; Balcells, Marc; Ferguson, Henry C.; Goudfrooij, Paul; Carter, David; Guzman, Rafael; Peletier, Reynier F.; hide

    2010-01-01

    The Coma cluster, Abell 1656, was the target of a HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in early 2007, the partially-completed survey still covers approximately 50% of the core high density region in Coma. Observations were performed for twenty-five fields with a total coverage area of 274 aremin(sup 2), and extend over a wide range of cluster-centric radii (approximately 1.75 Mpe or 1 deg). The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the south-west region of the cluster. In this paper we present SEXTRACTOR source catalogs generated from the processed images, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SEXTRACTOR Kron magnitudes based only on the measured source flux and its half-light radius. We have performed photometry for 76,000 objects that consist of roughly equal numbers of extended galaxies and unresolved objects. Approximately two-thirds of all detections are brighter than F814W=26.5 mag (AB), which corresponds to the 10sigma, point-source detection limit. We estimate that Coma members are 5-10% of the source detections, including a large population of compact objects (primarily GCs, but also cEs and UCDs), and a wide variety of extended galaxies from cD galaxies to dwarf low surface brightness galaxies. The initial data release for the HST-ACS Coma Treasury program was made available to the public in August 2008. The images and catalogs described in this study relate to our second data release.

  19. China's Propaganda in the United States during World War II.

    Science.gov (United States)

    Tsang, Kuo-jen

    Drawing data from a variety of sources, a study was undertaken to place China's propaganda activities in the United States during World War II into a historical perspective. Results showed that China's propaganda efforts consisted of official and unofficial activities and activities directed toward overseas Chinese. The official activities were…

  20. Optimization of simultaneous electrochemical determination of Cd(II), Pb(II), Cu(II) and Hg(II) at carbon nanotube-modified graphite electrodes.

    Science.gov (United States)

    Pikna, L'ubomír; Heželová, Mária; Kováčová, Zuzana

    2015-01-01

    The health of the environment is worsening every day. Monitoring of potentially toxic elements and remediation of environmental pollution are necessary. Therefore, the research and development of simple, inexpensive, portable and effective sensors is important. Electrochemistry is a useful component of the field of environment monitoring. The present study focuses on evaluating and comparing three types of electrodes (PIGE, PIGE/MWCNT/HNO3 and PIGE/MWCNT/EDTA/HNO3) employed for the simultaneous electrochemical determination of four potentially toxic elements: Cd(II), Pb(II), Cu(II) and Hg(II). Cyclic voltammograms were measured in an acetate buffer. The LOD, LOQ, the standard and relative precisions of the method and a prediction intervals were calculated (according to the technical procedure DIN 32 645) for the three electrodes and for each measured element. The LOD for PIGE/CNT/HNO3 (the electrode with narrowest calculated prediction intervals) was 2.98 × 10(-7) mol L(-1) for Cd(II), 4.83 × 10(-7) mol L(-1) for Pb(II), 3.81 × 10(-7) mol L(-1) for Cu(II), 6.79 × 10(-7) mol L(-1) for Hg(II). One of the benefits of this study was the determination of the amount of Hg(II) in the mixture of other elements.

  1. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II), Co(II), Ni(II), Cu(II), and Zn(II)] metals

    OpenAIRE

    Nahid Nishat; Ashraf Malik

    2016-01-01

    A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II), Co(II), Ni(II), Cu(II) and Zn(II). All the polymeric compounds were characterized by (FT-IR) spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA) and antibacterial activities. Polymer complexes of Mn(II), Co(II) and Ni(II) show octahedral geometry, wh...

  2. FEASIBILITY STUDY II OF A MUON BASED NEUTRINO SOURCE.

    Energy Technology Data Exchange (ETDEWEB)

    GALLARDO,J.C.; OZAKI,S.; PALMER,R.B.; ZISMAN,M.

    2001-06-30

    The concept of using a muon storage ring to provide a well characterized beam of muon and electron neutrinos (a Neutrino Factory) has been under study for a number of years now at various laboratories throughout the world. The physics program of a Neutrino Factoryis focused on the relatively unexplored neutrino sector. In conjunction with a detector located a suitable distance from the neutrino source, the facility would make valuable contributions to the study of neutrino masses and lepton mixing. A Neutrino Factory is expected to improve the measurement accuracy of sin{sup 2}(2{theta}{sub 23}) and {Delta}m{sup 2}{sub 32} and provide measurements of sin{sup 2}(2{theta}{sub 13}) and the sign of {Delta}m{sup 2}{sub 32}. It may also be able to measure CP violation in the lepton sector.

  3. Extraction studies of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II) using N, N', N, N' -Bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2-pyridylmethyl)) -ethylenediamine as a novel ligand

    International Nuclear Information System (INIS)

    Laus, R.; Anjos, A.D.; Naves, A.

    2008-01-01

    In the present study, the use of N,N',N,N'-bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2- pyridylmethyl))-ethylenediamine (H2L) as ligand was evaluated in the liquid-liquid (water- chloroform) extraction of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II). Experiments were carried out to determine the pH for maximum extraction for each metal ion by ligand, maximum extraction capacity, extraction kinetics and extraction selectivity. The results revealed that the extraction of metal ions is dependent on the pH: maximum extraction maximum was obtained in the pH range of 4.5 - 6.0 for Cu(II) and 8.0 - 9.0 for Zn(II). Cd(II) and Mn(II) were best extracted at pH 9.0 and Ni(II) at 10.0. The ligand H2L was effective for the extraction of Cd(II), Cu(II) and Zn(II) (extraction efficient, %E equal 100%), whereas %E of 76% and 23.5% were observed for Mn(II) and Ni(II), respectively. The ligand presented high selectivity for the extraction of Cu(II) at pH 4.0. (author)

  4. Preparation and Spectral Properties of Mixed-Ligand Complexes of VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II with Dimethylglyoxime and N-acetylglycine

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2010-01-01

    Full Text Available A number of mixed-ligand complexes of the general formula [M(D(G] where D=dimethylglyoximato monoanion, G=N-acetylglycinato and M=VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II were prepared. Each complex was characterized by elemental analysis, determination of metal, infrared spectra, electronic spectra, (1H and 13C NMR spectra, conductivity and magnetic moments. All these complexes were not soluble in some of the organic solvent but highly soluble in dimethylformamide. The conductivity data showed the non-electrolytic nature of the complexes. The electronic spectra exhibited absorption bands in the visible region caused by the d-d electronic transition such as VO(IV, Ni(II and Pd(II. The IR and (1H, 13C NMR spectra which have indicate that the dimethylglyoxime was coordinated with the metal ions through the N and O atoms of the oxime group and N-acetylglycine was coordinated with metal ions through the N atom and terminal carboxyl oxygen atom.

  5. Optical and mechanical design of the extended x-ray absorption fine structure (EXAFS) beam-line at Indus-II synchrotron source

    International Nuclear Information System (INIS)

    Das, N.C.; Jha, S.N.; Bhattacharyya, D.; Sinha, A.K.; Mishra, V.K.; Verma, Vishnu; Ghosh, A.K.

    2002-11-01

    An extended x-ray absorption fine structure (EXAFS) beam line for x-ray absorption studies using energy dispersive geometry and position sensitive detector is being designed for the INDUS-II Synchrotron source. The beam line would be used for doing x-ray absorption experiments involving measurements of fme structures above the absorption edge of different species of atoms in a material The results of the above experiments would lead to the determination of different important structural parameters of materials viz.. inter-atomic distance. co-ordination number, degree of disorder and radial distribution function etc. The optical design of the beam line has been completed based on the working principle that a single crystal bent in the shape of an ellipse by a crystal bender would act as a dispersing as well as focusing element. The mechanical design of the beam line including the crystal bender has also been completed and discussed here. Calculations have been done to detennine the temperature profile on the different components of the beam line under exposure to synchrotron radiation and proper cooling channels have been designed to bring down the heat load on the components. (author)

  6. Synthesis and characterization of polychelates of Cu(II), Ni(II), Co(II), Mn(II), Zn(II), oxovanadium(IV) and dioxouranium(VI) with 2,4-dihydroxybenzaldehyde-urea-formaldehyde polymer

    International Nuclear Information System (INIS)

    Patel, G.C.; Pancholi, H.B.; Patel, M.M.

    1991-01-01

    Polychelates of Cu(II), Ni(II), Co(II), Mn(II), Zn(II), oxovandium(IV) and dioxouranium(VI) with 2,4-dihydroxybenzaldehyde (2,4-DB)-urea(U)-formaldehyde(F) polymer (2,4-DBUF) have been prepared. Elemental analyses of the polychelates indicate a metal:ligand ratio of 1:2. The structures of the polychelates have been assigned on the basis of their elemental analyses, IR, reflectance spectra, magnetic moment, thermal data and their electrical conductivity behaviour. (author). 1 tab., 18 refs

  7. Ni (II) and Cu(II) complexes of

    African Journals Online (AJOL)

    ADOWIE PERE

    ABSTRACT: The objective of this study is to investigate the antimicrobial activity of novel. Schiff base metal complexes. The resistance of micro-organisms to classical antimicrobial compounds poses a challenge to effective management and treatment of some diseases. In line with this, copper (II), nickel (II) and cobalt (II) ...

  8. Sodium source development for pulsed power driven, photopumped NA/NE x-ray laser experiments

    International Nuclear Information System (INIS)

    Burkhalter, P.G.; Cooperstein, G.; Mosher, D.; Ottinger, P.F.; Scherrer, V.E.; Stephanakis, S.J.; Young, F.C.; Hinshelwood, D.D.; Mehlman, G.; Welch, B.L.; Jones, W.D.

    1988-01-01

    A sodium plasma source is being developed for a resonant photopumping x-ray laser scheme in which the 11A 1s 2 - 1s2rho 1 P 1 line in heliumlike Na X is used to pump the Ne IX n=4 singlet level. In their experiment the NRL Gamble II generator is used to produce two z-pinch plasmas in a side-by-side geometry. The sodium plasma is produced on axis and conducts the full 1 MA machine current. A fraction of this current returns through a neon gas puff located 5 cm from the sodium. This separation is determined by the need to prevent the plasmas from mixing and the need to have each plasma's azimuthal magnetic field as symmetric as possible. A minimum separation is desirable to increase coupling efficiency. To improve the pump source, a more confined source of pure sodium involving a coaxial plasma gun is being developed. They are currently studying both the operation of this source on a test stand and implosions of the resulting plasma on Gamble II. In initial experiments aluminum is substituted for sodium. Test stand diagnostics include photodiodes, witness plates, and current monitors designed to investigate the early motion of the annular plasma. Results from test stand and Gamble II experiments with both aluminum and sodium, as well as sodium handling techniques, are presented

  9. Synthesis and characterization of chromium(III), manganese(II), iron(III), cobalt(II), nickel(II), copper(II), cadmium(II) and dioxouranium(VI) complexes of 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone

    International Nuclear Information System (INIS)

    Abu El-Reash, G.M.; Ibrahim, M.M.; Kenawy; El-Ayaan, Usama; Khattab, M.A.

    1994-01-01

    A few complexes of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and dioxouranium(VI) with 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone have been synthesised and characterized on the basis of elemental analysis, IR, electronic NMR, and magnetic moment data. An octahedral structure is proposed for the Cr(III), Fe(III), Co(II) and Ni(H 3 PBT) 2 Cl 2 .2H 2 O complexes; a tetrahedral structure for the Mn(II) and Ni 2 (PBT)OAc.H 2 0 complexes and a square planar structure for the Cu(II) complexes. The antimicrobial and antifungal activities of H 3 PBT and of its metal(II) complexes are investigated. The results reveal that H 3 PBT exhibits greater antimicrobial activities than its complexes. (author). 34 refs., 4 figs., 2 tabs

  10. Source apportionment of ambient volatile organic compounds in the Pearl River Delta, China: Part II

    Science.gov (United States)

    Liu, Ying; Shao, Min; Lu, Sihua; Chang, Chih-Chung; Wang, Jia-Lin; Fu, Linlin

    The chemical mass balance receptor model was applied to the source apportionment of 58 hydrocarbons measured at seven sites in a field campaign that examined regional air quality in the Pearl River Delta (PRD) region in the fall of 2004. A total of 12 volatile organic compound (VOC) emission sources were considered, including gasoline- and diesel-powered vehicle exhausts, headspace vapors of gasoline and diesel fuel, vehicle evaporative emissions, liquid petroleum gas (LPG) leakage, paint vapors, asphalt emissions from paved roads, biomass combustion, coal combustion, the chemical industry, and petroleum refineries. Vehicle exhaust was the largest source of VOCs, contributing to >50% of ambient VOCs at the three urban sites (Guangzhou, Foshan, and Zhongshan). LPG leakage played an important role, representing 8-16% of emissions at most sites in the PRD. Solvent usage was the biggest emitter of VOCs at Dongguan, an industrial site, contributing 33% of ambient VOCs. Similarly, at Xinken, a non-urban site, the evaporation of solvents and coatings was the largest emission source, accounting for 31% of emissions, probably because it was downwind of Dongguan. Local biomass combustion was a noticeable source of VOCs at Xinken; although its contribution was estimated at 14.3%, biomass combustion was the third largest VOC source at this site.

  11. Copper (II)

    African Journals Online (AJOL)

    CLEMENT O BEWAJI

    Valine (2 - amino - 3 – methylbutanoic acid), is a chemical compound containing .... Stability constant (Kf). Gibb's free energy. ) (. 1. −. ∆. Mol. JG. [CuL2(H2O)2] ... synthesis and characterization of Co(ii), Ni(ii), Cu (II), and Zn(ii) complexes with ...

  12. Synthesis and Spectral Investigations of Manganese(II, Cobalt(II, Nickel(II, Copper(II and Zinc(II Complexes of New Polydentate Ligands Containing a 1,8-Naphthyridine Moiety

    Directory of Open Access Journals (Sweden)

    Sunkari Jyothi

    2006-12-01

    Full Text Available 2-(o-Hydroxyphenyl-1,8-naphthyridine (HN, 2-(4-hydroxy-6-methylpyran-2-one-3-yl-1,8-naphthyridine (HMPN and 2-(benzimidazol-2-yl-1,8-naphthyridine(BN react with acetates of Mn(II, Co(II, Ni(II, Cu(II and Zn(II to yield metal ioncomplexes of definite composition. These compounds were characterized by elementalanalyses, molar conductivity, magnetic susceptibility measurements, thermal studies, IR,UV-visible, NMR and mass spectral investigations. The complexes are found to have theformulae [M(HN2(H2O2], [M(HMPN2(H2O2] and [M(BN2(OAc2], respectively.

  13. Characteristics of AKR sources: A statistical description

    International Nuclear Information System (INIS)

    Hilgers, A.; Roux, A.; Lundin, R.

    1991-01-01

    A description of plasma properties within the sources of the Auroral Kilometric Radiation (AKR) is given. It is based on data collected during ∼ 50 AKR source crossings in the altitude range between 4,000 and 9,000 km by the Swedish spacecraft Viking. The following results are obtained; (i) the frequency of the lowest frequency peak of the AKR f peak is found to be very close to f ce , the electron gyrofrequency ((f peak -f ce )/f ce ≤ 0.08), on the average, (ii) the lower cutoff frequency f LC is on the average at f ce ((f LC -f ce )/f ce ≅ 0), (iii) in the sources the density is typically less than 1.5 cm -3 , which is of the order of the density of hot electrons and (iv) the source is located within an acceleration region, as evidenced by electrons accelerated above and ions accelerated below

  14. Dependence of proton beam polarization on ion source transition configurations; Determination de la polarisation du faisceau de protons pour les quatre configurations des transitions de la source d`ions

    Energy Technology Data Exchange (ETDEWEB)

    Arvieux, J.; Ausset, P.; Ball, J.; Beauvais, P.Y.; Bedfer, Y.; Chamouard, P.A.; Fontaine, J.M.; Kunne, R.; Lagniel, J.M.; Sans, J.L. [Laboratoire National Saturne - Centre d`Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France); Allgower, Ch.; Kasprzyk, T.E.; Spinka, H.M. [ANL-HEP, Argonne (United States); Bystricky, J.; Lehar, F.; Lesquen, A. de [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Demiere, Ph.; Rapin, D.; Teglia, A. [Geneva Univ. (Switzerland). Dept. de Physique Nucleaire et Corpusculaire; Janout, Z. [Czech Technical Univ., Prague (Czech Republic). Faculty of Civil Engineering; Kalinnikov, V.A.; Khachaturov, B.A.; Popov, A.A. [Laboratory of Nuclear Problems, JINR, Moscow (Russian Federation); Prokofiev, A.N.; Vikhrov, V.V.; Zhdanov, A.A. [Nuclear Physics Inst., St. Petersburg (Russian Federation)

    1997-12-31

    Considerable anomalies were observed in recorded pp elastic scattering spin dependent data at several proton beam energies at SATURNE II. These results suggested that the discrepancies are related to the polarized ion source. In order to understand the observed effects, the proton beam polarizations for each ion source state were determined separately. Convenient procedures, allowing to determine the beam polarization from a beam-line polarimeter are presented. Two distinct experiments are necessary for this purpose. In the first one the LEFT-RIGHT instrumental asymmetry of the beam polarimeter arms is determined. In the second one this correction factor is applied to asymmetries measured with the beam from the polarized ion source in different polarization states. Both experiments determined the scattering asymmetries for all four polarized source states as functions of different source parameters. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp elastic scattering analyzing power is at its maximum. Results show that the so called `unpolarized states` of the source are polarized, whereas the absolute values of the beam polarizations in `polarized states` are equal. It was observed that the hexapole lens of the ion source provides some beam polarization in the absence of any transition. The beam polarization as function of the hexapole current, of the transition efficiencies and of the rotation solenoid current has been studied. It is also shown, how one way obtain a strictly unpolarized beam using the polarized source only. The results obtained with the SATURNE II ion source HYPERION may be also valid for other accelerators and sources. (authors) 10 refs.

  15. Indian Summer Monsoon dynamics during Termination II and MIS 5e

    Science.gov (United States)

    Magiera, Matthias; Erhardt, Andrea M.; Hartland, Adam; Kwiecien, Ola; Cheng, Hai; Immenhauser, Adrian; Turchyn, Alexandra; Breitenbach, Sebastian F. M.

    2017-04-01

    The interpretation of speleothem oxygen isotope ratios (δ18O) as proxy for Indian Summer Monsoon (ISM) dynamics is ambiguous, due to multiple influencing factors. Here we combine δ18O and calcium isotope δ44Ca analyses with elemental data to delineate regional shifts in moisture source, local rainfall amount, and changes in ISM intensity and length during Termination II and MIS 5e. Oxygen isotope ratios reflect a mixed signal of moisture source dynamics and rainfall amount; δ44Ca and Mg/Ca ratios are interpreted as proxies for local effective moisture and prior calcite precipitation (PCP) in the epikarst. The age of stalagmite MAW-3 from Mawmluh Cave, NE India, is constraint by six U-series dates. 108 samples, obtained at 0.4 mm resolution from the 70 mm long speleothem sample, have been analysed for δ18O, δ44Ca and Mg/Ca. Oxygen isotope ratios were measured on a ThermoFisher Scientific MAT 253 at Ruhr-University Bochum. Elemental ratios were measured on a quadrupole ICP-MS at Waikato University. Calcium isotope ratios were analyzed on a ThermoFisher Scientific Triton at University of Cambridge. MAW-3 grew from 136 kyrs BP to 96 kyrs BP, covering Termination II and MIS 5e. Oxygen isotope values are high (ca. +0.91 ‰) during Termination II, reach a minimum during MIS 5e (-3.5 ‰), and rise again to -0.2 ‰ at the end of MIS 5e. Calcium isotope ratios range from -0.32 ‰ to -0.70 ‰ and show a positive correlation (R2= 0.7) with δ18O. High δ18O values during Termination II reflect reduced atmospheric circulation and/or a proximal moisture source (Bay of Bengal), implying lowered ISM intensity. A positive correlation of δ18O with δ44Ca suggests concurrent changes of moisture source location and local rainfall amount, with a proximal moisture source and reduced effective rainfall during periods of weak ISM. Elevated Mg/Ca ratios at such intervals corroborate PCP occurrence, which reflects dry conditions. The beginning of MIS 5e (ca. 132 kyrs BP) is

  16. GALAXY CLUSTERS IN THE IRAC DARK FIELD. II. MID-INFRARED SOURCES

    International Nuclear Information System (INIS)

    Krick, J. E.; Surace, J. A.; Yan, L.; Thompson, D.; Ashby, M. L. N.; Hora, J. L.; Gorjian, V.

    2009-01-01

    We present infrared (IR) luminosities, star formation rates (SFR), colors, morphologies, locations, and active galactic nuclei (AGNs) properties of 24 μm detected sources in photometrically detected high-redshift clusters in order to understand the impact of environment on star formation (SF) and AGN evolution in cluster galaxies. We use three newly identified z = 1 clusters selected from the IRAC dark field; the deepest ever mid-IR survey with accompanying, 14 band multiwavelength data including deep Hubble Space Telescope imaging and deep wide-area Spitzer MIPS 24 μm imaging. We find 90 cluster members with MIPS detections within two virial radii of the cluster centers, of which 17 appear to have spectral energy distributions dominated by AGNs and the rest dominated by SF. We find that 43% of the star-forming sample have IR luminosities L IR > 10 11 L sun (luminous IR galaxies). The majority of sources (81%) are spirals or irregulars. A large fraction (at least 25%) show obvious signs of interactions. The MIPS-detected member galaxies have varied spatial distributions as compared to the MIPS-undetected members with one of the three clusters showing SF galaxies being preferentially located on the cluster outskirts, while the other two clusters show no such trend. Both the AGN fraction and the summed SFR of cluster galaxies increase from redshift zero to one, at a rate that is a few times faster in clusters than over the same redshift range in the field. Cluster environment does have an effect on the evolution of both AGN fraction and SFR from redshift one to the present, but does not affect the IR luminosities or morphologies of the MIPS sample. SF happens in the same way regardless of environment making MIPS sources look the same in the cluster and field, however the cluster environment does encourage a more rapid evolution with time as compared to the field.

  17. NSLS-II injector commissioning and initial operation

    Energy Technology Data Exchange (ETDEWEB)

    Bacha, B.; Blum, E.; Bassi, B.; Bengtsson, J.; Blednykh, A.; Buda, S.; Cheng, W.; Choi, J.; Cuppolo, J.; D Alsace, R.; Davidsaver, M.; DeLong, J.; Doom, L.; Durfee, d.; fliller, R.; Fulkerson, M.; Ganetis, G.; Gao, F.; Gardner, C.; Guo, W.; Heese, R.; Hidaka, Y.; Hu, Y.; Johanson, M.; Kosciuk, B.; Kowalski, S.; Dramer, S.; Krinsky, S.; Li, Y.; Louie, W.; Maggipinto, M.; Marino, P.; Mead, J.; Oliva, G.; Padrazo, D.; Pedersen, K.; Podobedov, B.; Rainer, R.; Rose, J.; Santana, M.; Seletskiy, S.; Shaftan, T.; Singh, O.; Singh, P.; Smalyuk, V.; Smith, R.; Summers, T.; Tagger, J.; Tian, Y.; Wahl, W.; Wang, G.; Weiner, G.; Willeke, F.; Yang, L.; Yang, X.; Zeitler, E.; Zitvogel, E.; Zuhoski, P.

    2015-05-03

    The injector for the National Synchrotron Light Source II (NSLS-II) storage ring consists of a 3 GeV booster synchrotron and a 200 MeV S-band linac. The linac was designed to produce either a single bunch with a charge of 0.5 nC of electrons or a train of bunches up to 300 ns long containing a total charge of 15 nC. The booster was designed to accelerate up to 15 nC each cycle in a train of bunches up to 300 ns long. Linac commissioning was completed in April 2012. Booster commissioning was started in November 2013 and completed in March 2014. All of the significant design goals were satisfied including beam emittance, energy spread, and transport efficiency. While the maximum booster charge accelerated was only 10 nC, this has proven to be more than sufficient for storage ring commissioning and operation. The injector has operated reliably during storage ring operation since then. Results will be presented showing measurements of linac and booster operating parameters achieved during commissioning and initial operation. Operating experience and reliability during the first year of NSLS-II operation will be discussed.

  18. User's manual for the NEFTRAN II computer code

    International Nuclear Information System (INIS)

    Olague, N.E.; Campbell, J.E.; Leigh, C.D.; Longsine, D.E.

    1991-02-01

    This document describes the NEFTRAN II (NEtwork Flow and TRANsport in Time-Dependent Velocity Fields) computer code and is intended to provide the reader with sufficient information to use the code. NEFTRAN II was developed as part of a performance assessment methodology for storage of high-level nuclear waste in unsaturated, welded tuff. NEFTRAN II is a successor to the NEFTRAN and NWFT/DVM computer codes and contains several new capabilities. These capabilities include: (1) the ability to input pore velocities directly to the transport model and bypass the network fluid flow model, (2) the ability to transport radionuclides in time-dependent velocity fields, (3) the ability to account for the effect of time-dependent saturation changes on the retardation factor, and (4) the ability to account for time-dependent flow rates through the source regime. In addition to these changes, the input to NEFTRAN II has been modified to be more convenient for the user. This document is divided into four main sections consisting of (1) a description of all the models contained in the code, (2) a description of the program and subprograms in the code, (3) a data input guide and (4) verification and sample problems. Although NEFTRAN II is the fourth generation code, this document is a complete description of the code and reference to past user's manuals should not be necessary. 19 refs., 33 figs., 25 tabs

  19. Coordination behavior of tetraaza [N4] ligand towards Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes: Synthesis, spectroscopic characterization and anticancer activity

    Science.gov (United States)

    El-Boraey, Hanaa A.

    2012-11-01

    Novel eight Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes with [N4] ligand (L) i.e. 2-amino-N-{2-[(2-aminobenzoyl)amino]ethyl}benzamide have been synthesized and structurally characterized by elemental analysis, spectral, thermal (TG/DTG), magnetic, and molar conductivity measurements. On the basis of IR, mass, electronic and EPR spectral studies an octahedral geometry has been proposed for Co(II), Ni(II) complexes and Cu(II) chloride complex, square-pyramidal for Cu(I) bromide complex. For Cu(II) nitrate complex (6), Pd(II) complex (8) square planar geometry was proposed. The EPR data of Cu(II) complexes in powdered form indicate dx2-y2 ground state of Cu(II) ion. The antitumor activity of the synthesized ligand and some selected metal complexes has been studied. The palladium(II) complex (8) was found to display cytotoxicity (IC50 = 25.6 and 41 μM) against human breast cancer cell line MCF-7 and human hepatocarcinoma HEPG2 cell line.

  20. A design concept of target-moderator-reflector assemblies for KENS-II

    International Nuclear Information System (INIS)

    Watanabe, N.

    1991-01-01

    A design concept of KENS-II target-moderator-reflector assemblies is described. One of the assemblies is dedicated to the cold neutron source, and the other, to the thermal and epithermal neutron source. A flux-trap type moderator-configuration was adopted with a vertical proton-beam injection scheme. All moderators for the cold neutron source are coupled liquid hydrogen moderators with premoderators. A new scheme of proton beam delivery is proposed. The new system can provide several times higher total performance than a reference system based on a traditional single assembly with all decoupled moderators in a wing geometry and with a horizontal proton-beam injection scheme. (author)

  1. The epoch of cosmic heating by early sources of X-rays

    Science.gov (United States)

    Eide, Marius B.; Graziani, Luca; Ciardi, Benedetta; Feng, Yu; Kakiichi, Koki; Di Matteo, Tiziana

    2018-05-01

    Observations of the 21 cm line from neutral hydrogen indicate that an epoch of heating (EoH) might have preceded the later epoch of reionization. Here we study the effects on the ionization state and the thermal history of the intergalactic medium (IGM) during the EoH induced by different assumptions on ionizing sources in the high-redshift Universe: (i) stars; (ii) X-ray binaries (XRBs); (iii) thermal bremsstrahlung of the hot interstellar medium (ISM); and (iv) accreting nuclear black holes (BHs). To this aim, we post-process outputs from the (100 h-1 comoving Mpc)3 hydrodynamical simulation MassiveBlack-II with the cosmological 3D radiative transfer code CRASH, which follows the propagation of ultraviolet and X-ray photons, computing the thermal and ionization state of hydrogen and helium through the EoH. We find that stars determine the fully ionized morphology of the IGM, while the spectrally hard XRBs pave way for efficient subsequent heating and ionization by the spectrally softer ISM. With the seeding prescription in MassiveBlack-II, BHs do not contribute significantly to either ionization or heating. With only stars, most of the IGM remains in a cold state (with a median T = 11 K at z = 10), however, the presence of more energetic sources raises the temperature of regions around the brightest and more clustered sources above that of the cosmic microwave background, opening the possibility to observing the 21 cm signal in emission.

  2. Modeling Type II-P/II-L Supernovae Interacting with Recent Episodic Mass Ejections from Their Presupernova Stars with MESA and SNEC

    Science.gov (United States)

    Das, Sanskriti; Ray, Alak

    2017-12-01

    We show how dense, compact, discrete shells of circumstellar gas immediately outside of red supergiants affect the optical light curves of Type II-P/II-L supernovae (SNe), using the example of SN 2013ej. Earlier efforts in the literature had used an artificial circumstellar medium (CSM) stitched to the surface of an evolved star that had not gone through a phase of late-stage heavy mass loss, which, in essence, is the original source of the CSM. In contrast, we allow enhanced mass-loss rate from the modeled star during the 16O and 28Si burning stages and construct the CSM from the resulting mass-loss history in a self-consistent way. Once such evolved pre-SN stars are exploded, we find that the models with early interaction between the shock and the dense CSM reproduce light curves far better than those without that mass loss and, hence, having no nearby dense CSM. The required explosion energy for the progenitors with a dense CSM is reduced by almost a factor of two compared to those without the CSM. Our model, with a more realistic CSM profile and presupernova and explosion parameters, fits observed data much better throughout the rise, plateau, and radioactive tail phases as compared to previous studies. This points to an intermediate class of supernovae between Type II-P/II-L and Type II-n SNe with the characteristics of simultaneous UV and optical peak, slow decline after peak, and a longer plateau.

  3. 40 CFR 63.100 - Applicability and designation of source.

    Science.gov (United States)

    2010-07-01

    ... Manufacturing Industry § 63.100 Applicability and designation of source. (a) This subpart provides applicability...), or accepted engineering practices. If the total annual HAP emissions for the plant site are annually... system will be replaced; (ii) A barrier fluid system will be installed; (iii) A new barrier fluid will be...

  4. Sediment sources and their Distribution in Chwaka Bay, Zanzibar ...

    African Journals Online (AJOL)

    This work establishes sediment sources, character and their distribution in Chwaka Bay using (i) stable isotopes compositions of organic carbon (OC) and nitrogen, (ii) contents of OC, nitrogen and CaCO3, (iii) C/N ratios, (iv) distribution of sediment mean grain size and sorting, and (v) thickness of unconsolidated sediments.

  5. Particle beam source development

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Electron beam research directed toward providing improved in-diode pinched beam sources and establishing the efficiency and feasibility for superposition of many beams progressed in three major areas. Focusing stability has been improved from large effective aspect ratio (radius/gap of emitting surface) diodes. Substantial progress toward establishing the feasibility of combining beams guided along ionized current-carrying channels has been made. Two beams have been transported and overlayed on a target. Theoretical and experimental measurements on channel formation have resulted in specifications for the capacitor bank channel initiation system for a 12-beam combination experiment on Proto II. An additional area of beam research has been the development of a small pulsed X-ray source to yield high quality flash X-radiography of pellets. A source yielding approximately 100-μm resolution of objects has been demonstrated and work continues to improve the convenience and reliability of this source. The effort to extend the capability of higher power conventional pulse power generators to accelerate ions (rather than electrons), and assess the feasibility of this technology variation for target experiments and reactors has progressed. Progress toward development of a multistage accelerator for ions with pulse power technology centered on development of a new laboratory facility and design and procurement of hardware for a five-stage test apparatus for the Pulslac concept

  6. Single-channel source separation using non-negative matrix factorization

    DEFF Research Database (Denmark)

    Schmidt, Mikkel Nørgaard

    -determined and its solution relies on making appropriate assumptions concerning the sources. This dissertation is concerned with model-based probabilistic single-channel source separation based on non-negative matrix factorization, and consists of two parts: i) three introductory chapters and ii) five published...... papers. The first part introduces the single-channel source separation problem as well as non-negative matrix factorization and provides a comprehensive review of existing approaches, applications, and practical algorithms. This serves to provide context for the second part, the published papers......, in which a number of methods for single-channel source separation based on non-negative matrix factorization are presented. In the papers, the methods are applied to separating audio signals such as speech and musical instruments and separating different types of tissue in chemical shift imaging....

  7. The Source Inversion Validation (SIV) Initiative: A Collaborative Study on Uncertainty Quantification in Earthquake Source Inversions

    Science.gov (United States)

    Mai, P. M.; Schorlemmer, D.; Page, M.

    2012-04-01

    Earthquake source inversions image the spatio-temporal rupture evolution on one or more fault planes using seismic and/or geodetic data. Such studies are critically important for earthquake seismology in general, and for advancing seismic hazard analysis in particular, as they reveal earthquake source complexity and help (i) to investigate earthquake mechanics; (ii) to develop spontaneous dynamic rupture models; (iii) to build models for generating rupture realizations for ground-motion simulations. In applications (i - iii), the underlying finite-fault source models are regarded as "data" (input information), but their uncertainties are essentially unknown. After all, source models are obtained from solving an inherently ill-posed inverse problem to which many a priori assumptions and uncertain observations are applied. The Source Inversion Validation (SIV) project is a collaborative effort to better understand the variability between rupture models for a single earthquake (as manifested in the finite-source rupture model database) and to develop robust uncertainty quantification for earthquake source inversions. The SIV project highlights the need to develop a long-standing and rigorous testing platform to examine the current state-of-the-art in earthquake source inversion, and to develop and test novel source inversion approaches. We will review the current status of the SIV project, and report the findings and conclusions of the recent workshops. We will briefly discuss several source-inversion methods, how they treat uncertainties in data, and assess the posterior model uncertainty. Case studies include initial forward-modeling tests on Green's function calculations, and inversion results for synthetic data from spontaneous dynamic crack-like strike-slip earthquake on steeply dipping fault, embedded in a layered crustal velocity-density structure.

  8. Getting to the Source: a Survey of Quantitative Data Sources Available to the Everyday Librarian: Part 1: Web Server Log Analysis

    Directory of Open Access Journals (Sweden)

    Lisa Goddard

    2007-03-01

    Full Text Available This is the first part of a two‐part article that provides a survey of data sources which are likely to be immediately available to the typical practitioner who wishes to engage instatistical analysis of collections and services within his or her own library. Part I outlines the data elements which can be extracted from web server logs, and discusses web log analysis tools. Part II looks at logs, reports, and data sources from proxy servers, resource vendors, link resolvers, federated search engines, institutional repositories, electronic reference services, and the integrated library system.

  9. Study of the GERDA Phase II background spectrum

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevzik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-09-01

    The Gerda experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy, searches for the neutrinoless double beta (0νββ) decay of 76Ge. Gerda Phase II is aiming to reach a sensitivity for the 0νββ half life of 1026 yr in ˜ 3 years of physics data taking with 100 kg·yr of exposure and a background index of ˜ 10-3 cts/(keV·kg·yr). After 6 months of acquisition a first data release with 10.8 kg·yr of exposure is performed, showing that the design background is achieved. In this work a study of the Phase II background spectrum, the main spectral structures and the background sources will be presented and discussed.

  10. Characterization of cloned cells from an immortalized fetal pulmonary type II cell line

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, R.F.; Waide, J.J.; Lechner, J.F.

    1995-12-01

    A cultured cell line that maintained expression of pulmonary type II cell markers of differentiation would be advantageous to generate a large number of homogenous cells in which to study the biochemical functions of type II cells. Type II epithelial cells are the source of pulmonary surfactant and a cell of origin for pulmonary adenomas. Last year our laboratory reported the induction of expression of two phenotypic markers of pulmonary type II cells (alkaline phosphatase activity and surfactant lipid synthesis) in cultured fetal rat lung epithelial (FRLE) cells, a spontaneously immortalized cell line of fetal rat lung type II cell origin. Subsequently, the induction of the ability to synthesize surfactant lipid became difficult to repeat. We hypothesized that the cell line was heterogenuous and some cells were more like type II cells than others. The purpose of this study was to test this hypothesis and to obtain a cultured cell line with type II cell phenotypic markers by cloning several FRLE cells and characterizing them for phenotypic markers of type II cells (alkaline phosphatase activity and presence of surfactant lipids). Thirty cloned cell lines were analyzed for induced alkaline phosphatase activity (on x-axis) and for percent of phospholipids that were disaturated (i.e., surfactant).

  11. Removal of nickel(II and palladium(II from surface waters

    Directory of Open Access Journals (Sweden)

    V. Sharifzade

    2013-04-01

    Full Text Available A new sorbent was prepared using alumina and 5-Br-PADAP, and its adsorption ability for the removal of Ni(II and Pd(II from different waters was investigated. The procedure is based on retention of the analytes on the alumina load with 5-Br-PADAP at pH ~ 6. The separation/preconcentration conditions for the quantitative recoveries were investigated. The limit of detections (LOD based on three times the standard deviations of the blank, were 0.187 and 0.253 ng mL-1 for Ni(II and Pd(II, respectively. Obtained sorption capacities for 1 g sorbent were 6.0 mg Ni(II and 11.0 mg Pd(II. The linearity was maintained in the concentration range of 0.625 to 6.0 ng mL-1 for Ni(II and 0.416 to 7.0 ng mL-1 for Pd(II in the original solution. Eight replicate determinations of a mixture containing 2.0 µg mL-1 each of the elements in the final solution gave relative standard deviation of ±0.82 and ±1.12% for Ni(II and Pd(II, respectively. The proposed method was successfully applied to the determination trace amounts of Ni(II and Pd(II in the surface water samples.DOI: http://dx.doi.org/10.4314/bcse.v27i1.2

  12. Synthesis, spectral and thermal studies of pyridyl adducts of Zn(II) and Cd(II) dithiocarbamates, and their use as single source precursors for ZnS and CdS nanoparticles

    OpenAIRE

    Onwudiwe, Damian C.; Strydom, Christien A.; Jordaan, Anine; Oluwafemi, Oluwatobi S.; Hosten, Eric

    2014-01-01

    The synthesis, spectroscopic characterisation, and thermal studies of pyridyl adducts of Zn(II) and Cd(II) complexes of N-ethyl-N-phenyl dithiocarbamate, represented as [ZnL2py] and [CdL2py2], are reported. Single-crystal X-ray structural analysis of the Zn compound showed that it is five-coordinate with four sulphurs from dithiocarbamate and one nitrogen from pyridine in a distorted square pyramidal geometry. The thermogravimetric studies indicate that the zinc and cadmium compou...

  13. Evaluation of the computerized procedures Manual II (COPMA II)

    International Nuclear Information System (INIS)

    Converse, S.A.

    1995-11-01

    The purpose of this study was to evaluate the effects of a computerized procedure system, the Computerized Procedure Manual II (COPMA-II), on the performance and mental workload of licensed reactor operators. To evaluate COPMA-II, eight teams of two operators were trained to operate a scaled pressurized water reactor facility (SPWRF) with traditional paper procedures and with COPMA-II. Following training, each team operated the SPWRF under normal operating conditions with both paper procedures and COPMA-II. The teams then performed one of two accident scenarios with paper procedures, but performed the remaining accident scenario with COPMA-II. Performance measures and subjective estimates of mental workload were recorded for each performance trial. The most important finding of the study was that the operators committed only half as many errors during the accident scenarios with COPMA-II as they committed with paper procedures. However, time to initiate a procedure was fastest for paper procedures for accident scenario trials. For performance under normal operating conditions, there was no difference in time to initiate or to complete a procedure, or in the number of errors committed with paper procedures and with COPMA-II. There were no consistent differences in the mental workload ratings operators recorded for trials with paper procedures and COPMA-II

  14. Magic gamma rays, extra-atmospheric source

    International Nuclear Information System (INIS)

    Bolufer, P.

    2010-01-01

    Without the atmospheric layer, the cosmos radiation would kill every living, our planet would be like the moon. The cosmic gamma ray to collide with gases in land cover, as it is disintegrated. They are harmless, they form a cone of light that points to the cosmic source comes from. On April 25, 2009 was born on the island of Palma Magic II and Magic I the best observer of atmospheric gamma rays of low intensity. (Author)

  15. Efficiency of Chitosan for the Removal of Pb (II, Fe (II and Cu (II Ions from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Soheil Sobhanardakani

    2014-09-01

    Full Text Available Background: Heavy metals have been recognized as harmful environmental pollutant known to produce highly toxic effects on different organs and systems of both humans and animals. The aim of this paper is to evaluate the adsorption potential of chitosan for the removal of Pb(II, Fe(II and Cu(II ions from aqueous solutions. Methods: This study was conducted in laboratory scale. In this paper chitosan has been used as an adsorbent for the removal of Pb(II, Fe(II and Cu(II from aqueous solution. In batch tests, the effects of parameters like pH solution (1.0-8.0, initial metal concentrations (100-1000 mgL-1, contact time (5.0-150 min and adsorbent dose (1.0-7.0 g on the adsorption process were studied. Results: The results showed that the adsorption of Pb(II, Fe(II and Cu(II ions on chitosan strongly depends on pH. The experimental isothermal data were analyzed using the Langmuir and Freundlich equations and it was found that the removal process followed the Langmuir isotherm and maximum adsorption capacity for the adsorption of Pb(II, Fe(II and Cu(II ions by the chitosan were 55.5mg g−1, 71.4 mg g−1 and 59 mg g−1, respectively, under equilibrium conditions at 25±1 ºC. The adsorption process was found to be well described by the pseudo-second-order rate model. Conclusion: The obtained results showed that chitosan is a readily, available, economic adsorbent and was found suitable for removing Pb(II, Fe(II and Cu(II ions from aqueous solution.

  16. Spectrophotometric determination of cobalt(II), nickel(II) and copper (II) with 1-(2 pyridylazo)-2-naphthol in micellar medium

    International Nuclear Information System (INIS)

    Shar, G.A.; Soomro, G.A.

    2004-01-01

    Spectrophotometric determination of cobalt(II), nickel(II) and copper(II) is carried out with 1-(2 pyridylazo)-2-naphthol as a complexing reagent in aqueous phase using non-ionic surfactant Tween 80. Beer's law is obeyed for Co(II), Ni(II) and Cu(II) over the range 0.5 - 4.0, 0.5 - 4.0 and 0.5 - 3.0 ngmL/sup -1/ with detection limit (2 σ) of 6.7, 3.2 and 3.9 ngmL/sup -1/. The max molar absorption, molar absorptivity, Sandell's sensitivity of Co(II), Ni(II) and Cu(II) are 580 nm, 570 nm and 555 nm; max (104 mol/sup -1/ cm /sup -1/) is 0.87, 1.8 and 1.6 and 6.8, 3.3 and 3.9 ng cm-2 respectively. The pH at which complex is formed for Co(II), Ni(II) and Cu(II) is 5, 5.5 and 6.5 respectively. The critical micelle concentration (CMC) of Tween 80 is 5%. The present method is compared with that of atomic absorption spectroscopy and no significant difference is noted between the two methods at 95% confidence level. The method has been applied to the determination of Co(II), Ni(II) and Cu(II) in industrial waste water and pharmaceutical samples. (author)

  17. A Framework for the Systematic Collection of Open Source Intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Pouchard, Line Catherine [ORNL; Trien, Joseph P [ORNL; Dobson, Jonathan D [ORNL

    2009-01-01

    Following legislative directions, the Intelligence Community has been mandated to make greater use of Open Source Intelligence (OSINT). Efforts are underway to increase the use of OSINT but there are many obstacles. One of these obstacles is the lack of tools helping to manage the volume of available data and ascertain its credibility. We propose a unique system for selecting, collecting and storing Open Source data from the Web and the Open Source Center. Some data management tasks are automated, document source is retained, and metadata containing geographical coordinates are added to the documents. Analysts are thus empowered to search, view, store, and analyze Web data within a single tool. We present ORCAT I and ORCAT II, two implementations of the system.

  18. Probing jets from young embedded sources

    Science.gov (United States)

    Nisini, Brunella

    2017-08-01

    Jets are intimately related to the process of star formation and disc accretion. Our present knowledge of this key ingredient in protostars mostly relies on observations of optical jets from T Tauri stars, where the original circumstellar envelope has been already cleared out. However, to understand how jets are originally formed and how their properties evolve with time, detailed observations of young accreting protostars, i.e. the class 0/I sources, are mandatory. The study of class0/I jets will be revolutionised by JWST, able to penetrate protostars dusty envelopes with unprecedented sensitivity and resolution. However, complementary information on parameters inferred from lines in different excitation regimes, for at least a representative sample of a few bright sources, is essential for a correct interpretation of the JWST results. Here we propose to observe four prototype bright jets from class0/I sources with the WFC3 in narrow band filters in order to acquire high angular resolution images in the [OI]6300A, [FeII]1.25 and [FeII]1.64um lines. These images will be used to: 1) provide accurate extinction maps of the jets that will be an important archival reference for any future observation on these jets. 2) measure key parameters as the mass flux, the iron abundance and the jet collimation on the hot gas component of the jets. These information will provide an invaluable reference frame for a comparison with similar parameters measured by JWST in a different gas regime. In addition, these observations will allow us to confront the properties of class 0/I jets with those of the more evolved T Tauri stars.

  19. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II, Co(II, Ni(II, Cu(II, and Zn(II] metals

    Directory of Open Access Journals (Sweden)

    Nahid Nishat

    2016-09-01

    Full Text Available A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II, Co(II, Ni(II, Cu(II and Zn(II. All the polymeric compounds were characterized by (FT-IR spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA and antibacterial activities. Polymer complexes of Mn(II, Co(II and Ni(II show octahedral geometry, while polymer complexes of Cu(II and Zn(II show square planar and tetrahedral geometry, respectively. The TGA revealed that all the polymer metal complexes are more thermally stable than their parental ligand. In addition, biodegradable studies of all the polymeric compounds were also carried out through ASTM-D-5338-93 standards of biodegradable polymers by CO2 evolution method which says that coordination decreases biodegradability. The antibacterial activity was screened with the agar well diffusion method against some selected microorganisms. Among all the complexes, the antibacterial activity of the Cu(II polymer–metal complex showed the highest zone of inhibition because of its higher stability constant.

  20. Removal of Ni (II), Co (II) and Pb (II) ions from aqueous media using ...

    African Journals Online (AJOL)

    Removal of Ni (II), Co (II) and Pb (II) ions from aqueous media using Starch ... The results showed that 0.025 % loaded SSMNPs gave the optimal sorption ... constants (Lagergren and Pseudo-2nd-order) for Ni2+ and Co2+ adsorption were ... Langmuir correlation coefficients showed a better fit for the adsorption isotherms.

  1. Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) by hydrolyzed acrylamide-grafted PET films.

    Science.gov (United States)

    Rahman, Nazia; Sato, Nobuhiro; Sugiyama, Masaaki; Hidaka, Yoshiki; Okabe, Hirotaka; Hara, Kazuhiro

    2014-01-01

    Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) using hydrolyzed acrylamide (AAm)-grafted polyethylene terephthalate (PET) films was examined to explore the potential reuse of waste PET materials. Selective recovery of Hg(II) from a mixture of soft acids with similar structure, such as Hg(II) and Pb(II), is important to allow the reuse of recovered Hg(II). An adsorbent for selective Hg(II) adsorption was prepared by γ-ray-induced grafting of AAm onto PET films followed by partial hydrolysis through KOH treatment. The adsorption capacity of the AAm-grafted PET films for Hg(II) ions increased from 15 to 70 mg/g after partial hydrolysis because of the reduction of hydrogen bonding between -CONH2 groups and the corresponding improved access of metal ions to the amide groups. The prepared adsorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The absorbent film showed high selectivity for the adsorption of Hg(II) over Pb(II) throughout the entire initial metal concentration range (100-500 mg/L) and pH range (2.2-5.6) studied. The high selectivity is attributed to the ability of Hg(II) ions to form covalent bonds with the amide groups. The calculated selectivity coefficient for the adsorbent binding Hg(II) over Pb(II) was 19.2 at pH 4.5 with an initial metal concentration of 100 mg/L. Selective Hg(II) adsorption equilibrium data followed the Langmuir model and kinetic data were well fitted by a pseudo-second-order equation. The adsorbed Hg(II) and Pb(II) ions were effectively desorbed from the adsorbent film by acid treatment, and the regenerated film showed no marked loss of adsorption capacity upon reuse for selective Hg(II) adsorption.

  2. The Status of Kasimov Chinggisids during the Reigns of Vasily II and Ivan III according to Written Sources

    Directory of Open Access Journals (Sweden)

    M.A. Nesin

    2017-06-01

    Full Text Available Research objective: To study the issue both of the status of Kasimov Chinggisids as well as of the attitude toward the service Tatars and the Tatars who were allied to Moscow during the reigns of the great Moscow princes Vasily II and Ivan III. Research materials: Published and unpublished sources: books of official orders in the Russian state, chronicles, acts, diplomatic documents, etc. Results and novelty of the research: This work is the first comprehensive study of this topic. The author comes to the conclusion that Kasimov’s rulers during this period were considered servitors, vassals in relation to the Moscow principality. This was facilitated by the demesnial position of Kasimov, which was considered part of the grand prince’s domain rather than a sovereign splinter of the Golden Horde. Kasimov Chinggisids did not have a large military force in order to create an independent khanate in the steppe capable of competing, for example, with Kazan, and they relied on the strong Moscow principality performing military service for it, receiving money for proper maintenance and obeying the grand prince’s orders. At the same time, Ivan III even considered the possibility of replacing Daniyar in Kasimov with another serving prince during his lifetime. In addition, the author shows how much the attitude towards the service Tatars and the Tatar detachments, who were allied to Moscow, differed in different Russian lands.

  3. New Mn(II, Ni(II, Cd(II, Pb(II complexes with 2-methylbenzimidazole and other ligands. Synthesis, spectroscopic characterization, crystal structure, magnetic susceptibility and biological activity studies

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2016-11-01

    Full Text Available Synthesis and characterization of Mn(II, Ni(II, Cd(II and Pb(II mixed ligand complexes of 2-methylbenzimidazole with other ligands have been reported. The structure of the ligands and their complexes was investigated using elemental analysis, IR, UV–Vis, (1H, 13C NMR spectroscopy, molar conductivity and magnetic susceptibility measurements. In all the studies of complexes, the 2-methylbenzimidazole behaves as a neutral monodentate ligand which is coordinated with the metal ions through the N atom. While benzotriazole behaves as a neutral bidentate ligand which is coordinated with the Ni(II ion through the two N atoms. Moreover, the N-acetylglycine behaves as a bidentate ligand which is coordinated with the Mn(II, Ni(II and Pb(II ions through the N atom and the terminal carboxyl oxygen atom. The magnetic and spectral data indicate the tetrahedral geometry for Mn(II complex, irregular tetrahedral geometry for Pb(II complex and octahedral geometry for Ni(II complex. The X-ray single crystal diffraction method was used to confirm a centrosymmetric dinuclear Cd(II complex as each two metal ions are linked by a pair of thiocyanate N = S bridge. Two 2-methylbenzimidazole N-atom donors and one terminal thiocyanate N atom complete a highly distorted square pyramid geometry around the Cd atom. Besides, different cell types were used to determine the inhibitory effect of Mn(II, Ni(II, Cd(II and Pb(II complexes on cell growth using MTT assay. Cd(II complex showed cytotoxic effect on various types of cancer cell lines with different EC50 values.

  4. Accelerator Physics Challenges for the NSLS-II Project

    Energy Technology Data Exchange (ETDEWEB)

    Krinsky,S.

    2009-05-04

    The NSLS-II is an ultra-bright synchrotron light source based upon a 3-GeV storage ring with a 30-cell (15 super-period) double-bend-achromat lattice with damping wigglers used to lower the emittance below 1 nm. In this paper, we discuss the accelerator physics challenges for the design including: optimization of dynamic aperture; estimation of Touschek lifetime; achievement of required orbit stability; and analysis of ring impedance and collective effects.

  5. Radio Follow-up on All Unassociated Gamma-Ray Sources from the Third Fermi Large Area Telescope Source Catalog

    Energy Technology Data Exchange (ETDEWEB)

    Schinzel, Frank K. [National Radio Astronomy Observatory, P.O. Box O, Socorro, NM 87801 (United States); Petrov, Leonid [Astrogeo Center, Falls Church, VA 22043 (United States); Taylor, Gregory B. [Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM 87131 (United States); Edwards, Philip G., E-mail: fschinze@nrao.edu [CSIRO Astronomy and Space Science, P.O. Box 76, Epping, 1710 NSW (Australia)

    2017-04-01

    The third Fermi Large Area Telescope γ -ray source catalog (3FGL) contains over 1000 objects for which there is no known counterpart at other wavelengths. The physical origin of the γ -ray emission from those objects is unknown. Such objects are commonly referred to as unassociated and mostly do not exhibit significant γ -ray flux variability. We performed a survey of all unassociated γ -ray sources found in 3FGL using the Australia Telescope Compact Array and Very Large Array in the range 4.0–10.0 GHz. We found 2097 radio candidates for association with γ -ray sources. The follow-up with very long baseline interferometry for a subset of those candidates yielded 142 new associations with active galactic nuclei that are γ -ray sources, provided alternative associations for seven objects, and improved positions for another 144 known associations to the milliarcsecond level of accuracy. In addition, for 245 unassociated γ -ray sources we did not find a single compact radio source above 2 mJy within 3 σ of their γ -ray localization. A significant fraction of these empty fields, 39%, are located away from the Galactic plane. We also found 36 extended radio sources that are candidates for association with a corresponding γ -ray object, 19 of which are most likely supernova remnants or H ii regions, whereas 17 could be radio galaxies.

  6. MONSTIR II: A 32-channel, multispectral, time-resolved optical tomography system for neonatal brain imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Robert J., E-mail: robert.cooper@ucl.ac.uk; Magee, Elliott; Everdell, Nick; Magazov, Salavat; Varela, Marta; Airantzis, Dimitrios; Gibson, Adam P.; Hebden, Jeremy C. [Biomedical Optics Research Laboratory, Department of Medical Physics and Bioengineering, University College London, London WC1E 6BT (United Kingdom)

    2014-05-15

    We detail the design, construction and performance of the second generation UCL time-resolved optical tomography system, known as MONSTIR II. Intended primarily for the study of the newborn brain, the system employs 32 source fibres that sequentially transmit picosecond pulses of light at any four wavelengths between 650 and 900 nm. The 32 detector channels each contain an independent photo-multiplier tube and temporally correlated photon-counting electronics that allow the photon transit time between each source and each detector position to be measured with high temporal resolution. The system's response time, temporal stability, cross-talk, and spectral characteristics are reported. The efficacy of MONSTIR II is demonstrated by performing multi-spectral imaging of a simple phantom.

  7. Design and simulation of ion optics for ion sources for production of singly charged ions

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.

    2004-05-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments.

  8. Design and simulation of ion optics for ion sources for production of singly charged ions

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.

    2004-01-01

    During the last 2 years different types of the singly charged ion sources were developed for FLNR (JINR) new projects such as Dubna radioactive ion beams, (Phase I and Phase II), the production of the tritium ion beam and the MASHA mass separator. The ion optics simulations for 2.45 GHz electron cyclotron resonance source, rf source, and the plasma ion source were performed. In this article the design and simulation results of the optics of new ion sources are presented. The results of simulation are compared with measurements obtained during the experiments

  9. Chelation of Cu(II, Zn(II, and Fe(II by Tannin Constituents of Selected Edible Nuts

    Directory of Open Access Journals (Sweden)

    Magdalena Karamać

    2009-12-01

    Full Text Available The tannin fractions isolated from hazelnuts, walnuts and almonds were characterised by colorimetric assays and by an SE-HPLC technique. The complexation of Cu(II and Zn(II was determined by the reaction with tetramethylmurexide, whereas for Fe(II, ferrozine was employed. The walnut tannins exhibited a significantly weaker reaction with the vanillin/HCl reagent than hazelnut and almond tannins, but the protein precipitation capacity of the walnut fraction was high. The SE-HPLC chromatogram of the tannin fraction from hazelnuts revealed the presence of oligomers with higher molecular weights compared to that of almonds. Copper ions were most effectively chelated by the constituents of the tannin fractions of hazelnuts, walnuts and almonds. At a 0.2 mg/assay addition level, the walnut tannins complexed almost 100% Cu(II. The Fe(II complexation capacities of the tannin fractions of walnuts and hazelnuts were weaker in comparison to that of the almond tannin fraction, which at a 2.5 mg/assay addition level, bound Fe(II by ~90%. The capacity to chelate Zn(II was quite varied for the different nut tannin fractions: almond tannins bound as much as 84% Zn(II, whereas the value for walnut tannins was only 8.7%; and for hazelnut tannins, no Zn(II chelation took place at the levels tested.

  10. Stability constants of glutarate complexes of copper(II), zinc(II), cobalt(II) and uranyl(II) by paper electrophoresis

    International Nuclear Information System (INIS)

    Singh, R.K.P.; Yadava, J.R.; Yadava, K.L.

    1981-01-01

    Stability constants of Copper(II), Zinc(II), Cobalt(II) and Uranyl(II) glutarates have been determined by paper electrophoresis. Glutaric acid (0.005 mol dmsup(-3)) was added to the background electrolyte : 0.1 mol dmsup(-3) HClO 4 . The proportions of (CH 2 ) 3 COOH COO - and (CH 2 ) 3 C 2 O 4 2- were varied by changing the pH of the electrolyte. These anions yielded the complexes Cu(CH 2 ) 3 C 2 O 4 , [Zn(CH 2 ) 3 COOH COO] + [Co(CH 2 ) 3 COOH COO] + and UO 2 (CH 2 ) 3 C 2 O 4 whose stability constants are found to be 10sup(3.9), 10sup(2.9), 10sup(2.7) and 10sup(13.5) respectively. (author)

  11. Intravital Imaging Reveals Angiotensin II-Induced Transcytosis of Albumin by Podocytes.

    Science.gov (United States)

    Schießl, Ina Maria; Hammer, Anna; Kattler, Veronika; Gess, Bernhard; Theilig, Franziska; Witzgall, Ralph; Castrop, Hayo

    2016-03-01

    Albuminuria is a hallmark of kidney disease of various etiologies and usually caused by deterioration of glomerular filtration barrier integrity. We recently showed that angiotensin II (Ang II) acutely increases albumin filtration in the healthy kidney. Here, we used intravital microscopy to assess the effects of Ang II on podocyte function in rats. Acute infusion of 30, 60, or 80 ng/kg per minute Ang II enhanced the endocytosis of albumin by activation of the type 1 Ang II receptor and resulted in an average (±SEM) of 3.7±2.2, 72.3±18.6 (Palbumin-containing vesicles per glomerulus, respectively, compared with none at baseline or 10 ng/kg per minute Ang II. Immunostaining of Ang II-infused kidneys confirmed the presence of albumin-containing vesicles, which colocalized with megalin, in podocin-positive cells. Furthermore, podocyte endocytosis of albumin was markedly reduced in the presence of gentamicin, a competitive inhibitor of megalin-dependent endocytosis. Ang II infusion increased the concentration of albumin in the subpodocyte space, a potential source for endocytic protein uptake, and gentamicin further increased this concentration. Some endocytic vesicles were acidified and colocalized with LysoTracker. Most vesicles migrated from the capillary to the apical aspect of the podocyte and were eventually released into the urinary space. This transcytosis accounted for approximately 10% of total albumin filtration. In summary, the transcellular transport of proteins across the podocyte constitutes a new pathway of glomerular protein filtration. Ang II enhances the endocytosis and transcytosis of plasma albumin by podocytes, which may eventually impair podocyte function. Copyright © 2016 by the American Society of Nephrology.

  12. Multiband Study of Radio Sources of the RCR Catalogue with Virtual Observatory Tools

    Directory of Open Access Journals (Sweden)

    Zhelenkova O. P.

    2012-09-01

    Full Text Available We present early results of our multiband study of the RATAN Cold Revised (RCR catalogue obtained from seven cycles of the “Cold” survey carried with the RATAN-600 radio telescope at 7.6 cm in 1980-1999, at the declination of the SS 433 source. We used the 2MASS and LAS UKIDSS infrared surveys, the DSS-II and SDSS DR7 optical surveys, as well as the USNO-B1 and GSC-II catalogues, the VLSS, TXS, NVSS, FIRST and GB6 radio surveys to accumulate information about the sources. For radio sources that have no detectable optical candidate in optical or infrared catalogues, we additionally looked through images in several bands from the SDSS, LAS UKIDSS, DPOSS, 2MASS surveys and also used co-added frames in different bands. We reliably identified 76% of radio sources of the RCR catalogue. We used the ALADIN and SAOImage DS9 scripting capabilities, interoperability services of ALADIN and TOPCAT, and also other Virtual Observatory (VO tools and resources, such as CASJobs, NED, Vizier, and WSA, for effective data access, visualization and analysis. Without VO tools it would have been problematic to perform our study.

  13. Pb(II), Cd(II) and Zn(II) adsorption on low grade manganese ore ...

    African Journals Online (AJOL)

    Low grade manganese ore (LMO) of Orissa containing 58.37% SiO2, 25.05% MnO2, 8.8% Al2O3, and 5.03% Fe2O3 as the main constituents was taken to study its adsorption behaviour for Pb(II), Cd(II) and Zn(II) from aqueous solutions. The XRD studies showed the crystalline phases to be quartz, ß-MnO2, d-MnO2 and ...

  14. The research reactor BER II at the Helmholtz-Center Berlin

    Energy Technology Data Exchange (ETDEWEB)

    Krohn, Herbert [Helmholtz-Zentrum Berlin (HZB), Berlin (Germany)

    2012-10-15

    For basic and application-oriented research assignments the Helmholtz-Center Berlin (Helmholtz Zentrum Berlin - HZB) runs a research reactor that operates as a source of neutron beams for a wide range of scientific investigations. At the end of the 1980{sup th} the BER II was completed renewed and fitted with new experimental facilities. The BER II is a light water cooled and moderated swimming pool type reactor to be operated at 10 MW thermal power. Six neutron guides deliver cold neutrons from the cold moderator cell to a neutron guide hall adjacent to the experiment hall. With its 24 experimental stations, experimenters at HZB have practically all neutron scattering or neutron radiography techniques at their disposal. (orig.)

  15. The research reactor BER II at the Helmholtz-Center Berlin

    International Nuclear Information System (INIS)

    Krohn, Herbert

    2012-01-01

    For basic and application-oriented research assignments the Helmholtz-Center Berlin (Helmholtz Zentrum Berlin - HZB) runs a research reactor that operates as a source of neutron beams for a wide range of scientific investigations. At the end of the 1980 th the BER II was completed renewed and fitted with new experimental facilities. The BER II is a light water cooled and moderated swimming pool type reactor to be operated at 10 MW thermal power. Six neutron guides deliver cold neutrons from the cold moderator cell to a neutron guide hall adjacent to the experiment hall. With its 24 experimental stations, experimenters at HZB have practically all neutron scattering or neutron radiography techniques at their disposal. (orig.)

  16. The Spider Venom Peptide Lycosin-II Has Potent Antimicrobial Activity against Clinically Isolated Bacteria

    Directory of Open Access Journals (Sweden)

    Yongjun Wang

    2016-04-01

    Full Text Available Antimicrobial peptides have been accepted as excellent candidates for developing novel antibiotics against drug-resistant bacteria. Recent studies indicate that spider venoms are the source for the identification of novel antimicrobial peptides. In the present study, we isolated and characterized an antibacterial peptide named lycosin-II from the venom of the spider Lycosa singoriensis. It contains 21 amino acid residue lacking cysteine residues and forms a typical linear amphipathic and cationic α-helical conformation. Lycosin-II displays potent bacteriostatic effect on the tested drug-resistant bacterial strains isolated from hospital patients, including multidrug-resistant A. baumannii, which has presented a huge challenge for the infection therapy. The inhibitory ability of lycosin-II might derive from its binding to cell membrane, because Mg2+ could compete with the binding sites to reduce the bacteriostatic potency of lycosin-II. Our data suggest that lycosin-II might be a lead in the development of novel antibiotics for curing drug-resistant bacterial infections.

  17. Characterizing the Performance of the Princeton Advanced Test Stand Ion Source

    Science.gov (United States)

    Stepanov, A.; Gilson, E. P.; Grisham, L.; Kaganovich, I.; Davidson, R. C.

    2012-10-01

    The Princeton Advanced Test Stand (PATS) is a compact experimental facility for studying the physics of intense beam-plasma interactions relevant to the Neutralized Drift Compression Experiment - II (NDCX-II). The PATS facility consists of a multicusp RF ion source mounted on a 2 m-long vacuum chamber with numerous ports for diagnostic access. Ar+ beams are extracted from the source plasma with three-electrode (accel-decel) extraction optics. The RF power and extraction voltage (30 - 100 kV) are pulsed to produce 100 μsec duration beams at 0.5 Hz with excellent shot-to-shot repeatability. Diagnostics include Faraday cups, a double-slit emittance scanner, and scintillator imaging. This work reports measurements of beam parameters for a range of beam energies (30 - 50 keV) and currents to characterize the behavior of the ion source and extraction optics. Emittance scanner data is used to calculate the beam trace-space distribution and corresponding transverse emittance. If the plasma density is changing during a beam pulse, time-resolved emittance scanner data has been taken to study the corresponding evolution of the beam trace-space distribution.

  18. The spectrum of singly ionized oxygen, O II

    International Nuclear Information System (INIS)

    Wenaker, I.

    1990-01-01

    The spectrum of singly ionized oxygen, O II, emitted by a spark-generated, electrodeless discharge light source, has been investigated in the wavelength range 2100-11700 A. About 740 lines, 359 of which have not been reported earlier, were measured. As a result the energies of about 50 new levels have been determined, and the O II term system now presented includes 254 levels. The quartet system is firmly connected to the doublet system by 56 identified intersystem lines. The ionization limits have been determined by applying the polarization formula to the 4f, 5f, 5g and 6g levels. The experimentally determined value for the lowest limit, 2s 2 2p 2 3 P 0 , is 283270.9±0.5 cm -1 above the 2s 2 2p 3 4 S 3/2 ground state. (orig.)

  19. Crystal Structure of Rat Carnitine Palmitoyltransferase II (CPT-II)

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao,Y.; Jogl, G.; Esser, V.; Tong, L.

    2006-01-01

    Carnitine palmitoyltransferase II (CPT-II) has a crucial role in the {beta}-oxidation of long-chain fatty acids in mitochondria. We report here the crystal structure of rat CPT-II at 1.9 Angstroms resolution. The overall structure shares strong similarity to those of short- and medium-chain carnitine acyltransferases, although detailed structural differences in the active site region have a significant impact on the substrate selectivity of CPT-II. Three aliphatic chains, possibly from a detergent that is used for the crystallization, were found in the structure. Two of them are located in the carnitine and CoA binding sites, respectively. The third aliphatic chain may mimic the long-chain acyl group in the substrate of CPT-II. The binding site for this aliphatic chain does not exist in the short- and medium-chain carnitine acyltransferases, due to conformational differences among the enzymes. A unique insert in CPT-II is positioned on the surface of the enzyme, with a highly hydrophobic surface. It is likely that this surface patch mediates the association of CPT-II with the inner membrane of the mitochondria.

  20. Multi-metals column adsorption of lead(II), cadmium(II) and manganese(II) onto natural bentonite clay.

    Science.gov (United States)

    Alexander, Jock Asanja; Surajudeen, Abdulsalam; Aliyu, El-Nafaty Usman; Omeiza, Aroke Umar; Zaini, Muhammad Abbas Ahmad

    2017-10-01

    The present work was aimed at evaluating the multi-metals column adsorption of lead(II), cadmium(II) and manganese(II) ions onto natural bentonite. The bentonite clay adsorbent was characterized for physical and chemical properties using X-ray diffraction, X-ray fluorescence, Brunauer-Emmett-Teller surface area and cation exchange capacity. The column performance was evaluated using adsorbent bed height of 5.0 cm, with varying influent concentrations (10 mg/L and 50 mg/L) and flow rates (1.4 mL/min and 2.4 mL/min). The result shows that the breakthrough time for all metal ions ranged from 50 to 480 minutes. The maximum adsorption capacity was obtained at initial concentration of 10 mg/L and flow rate of 1.4 mL/min, with 2.22 mg/g of lead(II), 1.71 mg/g of cadmium(II) and 0.37 mg/g of manganese(II). The order of metal ions removal by natural bentonite is lead(II) > cadmium(II) > manganese(II). The sorption performance and the dynamic behaviour of the column were predicted using Adams-Bohart, Thomas, and Yoon-Nelson models. The linear regression analysis demonstrated that the Thomas and Yoon-Nelson models fitted well with the column adsorption data for all metal ions. The natural bentonite was effective for the treatment of wastewater laden with multi-metals, and the process parameters obtained from this work can be used at the industrial scale.

  1. Merotelic kinetochore attachment in oocyte meiosis II causes sister chromatids segregation errors in aged mice.

    Science.gov (United States)

    Cheng, Jin-Mei; Li, Jian; Tang, Ji-Xin; Hao, Xiao-Xia; Wang, Zhi-Peng; Sun, Tie-Cheng; Wang, Xiu-Xia; Zhang, Yan; Chen, Su-Ren; Liu, Yi-Xun

    2017-08-03

    Mammalian oocyte chromosomes undergo 2 meiotic divisions to generate haploid gametes. The frequency of chromosome segregation errors during meiosis I increase with age. However, little attention has been paid to the question of how aging affects sister chromatid segregation during oocyte meiosis II. More importantly, how aneuploid metaphase II (MII) oocytes from aged mice evade the spindle assembly checkpoint (SAC) mechanism to complete later meiosis II to form aneuploid embryos remains unknown. Here, we report that MII oocytes from naturally aged mice exhibited substantial errors in chromosome arrangement and configuration compared with young MII oocytes. Interestingly, these errors in aged oocytes had no impact on anaphase II onset and completion as well as 2-cell formation after parthenogenetic activation. Further study found that merotelic kinetochore attachment occurred more frequently and could stabilize the kinetochore-microtubule interaction to ensure SAC inactivation and anaphase II onset in aged MII oocytes. This orientation could persist largely during anaphase II in aged oocytes, leading to severe chromosome lagging and trailing as well as delay of anaphase II completion. Therefore, merotelic kinetochore attachment in oocyte meiosis II exacerbates age-related genetic instability and is a key source of age-dependent embryo aneuploidy and dysplasia.

  2. Antibacterial Co(II, Ni(II, Cu(II and Zn(II complexes with biacetyl-derived Schiff bases

    Directory of Open Access Journals (Sweden)

    MUHAMMAD IMRAN

    2010-08-01

    Full Text Available The condensation reactions of biacetyl with ortho-hydroxyaniline and 2-aminobenzoic acid to form bidendate NO donor Schiff bases were studied. The prepared Schiff base ligands were further utilized for the formation of metal chelates having the general formula [ML2(H2O2] where M = Co(II, Ni(II, Cu(II and Zn(II and L = HL1 and HL2. These new compounds were characterized by conductance measurements, magnetic susceptibility measurements, elemental analysis, and IR, 1H-NMR, 13C-NMR and electronic spectroscopy. Both Schiff base ligands were found to have a mono-anionic bidentate nature and octahedral geometry was assigned to all metal complexes. All the complexes contained coordinated water which was lost at 141–160 °C. These compounds were also screened for their in vitro antibacterial activity against four bacterial species, namely: Escherichia coli, Staphylococcus aureus, Salmonella typhi and Bacillus subtilis. The metal complexes were found to have greater antibacterial activity than the uncomplexed Schiff base ligands.

  3. Compact continuum radio sources in the Orion Nebula

    International Nuclear Information System (INIS)

    Garay, G.; Moran, J.M.; Reid, M.J.; European Southern Observatory, Garching, West Germany)

    1987-01-01

    The Orion Nebula was observed with the VLA in order to search for radio emission from compact H II regions indicative of embedded OB stars or from winds associated with pre-main sequence, low-mass stars. Fourteen of the 21 detected radio sources are within 30 arcsec of Omega 1 Orionis C; 13 of these objects are probably neutral condensations surrounded by ionized envelopes that are excited by the star. If the temperature of the ionized envelopes is 10,000 K and their electron densities decrease as the square of the distance from the core center, then a typical neutral condensation has a radius of 10 to the 15th cm and a peak electron density of 400,000/cu cm. Seven sources are in or near the Orion molecular cloud. Four of the sources have optical counterparts. Two are highly variable radio sources associated with X-ray sources, and two have radio spectra indicative of thermal emission. Two of the three optically invisible sources have radio emission likely to arise in a dense ionized envelope surrounding and excited by an early B-type star. 46 references

  4. THE SPECTRUM AND TERM ANALYSIS OF V II

    International Nuclear Information System (INIS)

    Thorne, A. P.; Pickering, J. C.; Semeniuk, J. I.

    2013-01-01

    The spectrum and extended term analysis of V II are presented. Fourier transform spectrometry was used to record high resolution spectra of singly ionized vanadium in the region 1492-5800 Å (67020-17260 cm –1 ) with vanadium-neon and vanadium-argon hollow cathode lamps as sources. The wavenumber uncertainty for the center of gravity of the strongest lines is typically 0.002 cm –1 , an improvement of an order of magnitude over previous measurements. Most of the lines exhibit partly resolved hyperfine structure. The V II energy levels in the 1985 compilation of Sugar and Corliss have been confirmed and revised, with the exception of the high-lying 4f levels and eight of the lower levels. Thirty-nine of the additional eighty-five high levels published by Iglesias et al. have also been confirmed and revised, and three of their missing levels have been found. The energy uncertainty of the revised levels has been reduced by about an order of magnitude. In total, 176 even levels and 233 odd levels are presented. Wavenumbers and classifications are given for 1242 V II lines

  5. SEPARATION OF Fe (III, Cr(III, Cu(II, Ni(II, Co(II, AND Pb(II METAL IONS USING POLY(EUGENYL OXYACETIC ACID AS AN ION CARRIER BY A LIQUID MEMBRANE TRANSPORT METHOD

    Directory of Open Access Journals (Sweden)

    La Harimu

    2010-06-01

    Full Text Available Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II  metal ions had been separated using poly(eugenyl oxyacetic acid as an ion carrier by bulk liquid membrane transport method. The effect of pH, polyeugenyl oxyacetic acid ion carrier concentration, nitric acid concentration in the stripping solution, transport time, and metal concentration were optimized. The result showed that the optimum condition for transport of metal ions was at pH 4 for ion Fe(III and at pH 5 for Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions. The carrier volumes were optimum with concentration of 1 x 10-3 M at 7.5 mL for Cr(III, Cu (II,  Ni(II, Co(II ions and at 8.5 mL for Fe(III and Pb(II ions. The concentration of HNO3 in stripping phase was optimum at 2 M for Fe(III and Cu(II ions, 1 M for Cr(III, Ni(II and Co(II ions, and 0.5 M for Pb(II ion. The optimum transport times were 36 h for Fe(III and Co(II ions, and 48 h for Cr(III, Cu (II, Ni(II, and Pb(II ions. The concentration of metal ions accurately transported were 2.5 x 10-4 M for Fe(III and Cr(III ions, and 1 M for Cu (II, Ni(II, Co(II, and Pb(II ions. Compared to other metal ions the transport of Fe(III was the highest with selectivity order of Fe(III > Cr(III > Pb(II > Cu(II > Ni(II > Co(II. At optimum condition, Fe(III ion was transported through the membrane at 46.46%.   Keywords: poly(eugenyl oxyacetic acid, transport, liquid membrane, Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions

  6. Synthesis and Characterization of Multimetallic Fe(II) and Mn(II ...

    African Journals Online (AJOL)

    Iron(II) and Manganese(II) complexes of the resulting ligand were obtained from its reactions with Fe(II) and Mn(II) salts in absolute methanol for the metal to ligand ratio 2:3. These complexes were characterized by Solubility, Conductivity, IR and UV-VIS spectrometry, elemental analysis and mass spectrometry. Keywords: ...

  7. (II) complexes

    African Journals Online (AJOL)

    activities of Schiff base tin (II) complexes. Neelofar1 ... Conclusion: All synthesized Schiff bases and their Tin (II) complexes showed high antimicrobial and ...... Singh HL. Synthesis and characterization of tin (II) complexes of fluorinated Schiff bases derived from amino acids. Spectrochim Acta Part A: Molec Biomolec.

  8. Complete Element Abundances of Nine Stars in the r-process Galaxy Reticulum II

    Science.gov (United States)

    Ji, Alexander P.; Frebel, Anna; Simon, Joshua D.; Chiti, Anirudh

    2016-10-01

    We present chemical abundances derived from high-resolution Magellan/Magellan Inamori Kyocera Echelle spectra of the nine brightest known red giant members of the ultra-faint dwarf galaxy Reticulum II (Ret II). These stars span the full metallicity range of Ret II (-3.5 contaminated known r-process pattern. The abundances of lighter elements up to the iron peak are otherwise similar to abundances of stars in the halo and in other ultra-faint dwarf galaxies. However, the scatter in abundance ratios is large enough to suggest that inhomogeneous metal mixing is required to explain the chemical evolution of this galaxy. The presence of low amounts of neutron-capture elements in other ultra-faint dwarf galaxies may imply the existence of additional r-process sites besides the source of r-process elements in Ret II. Galaxies like Ret II may be the original birth sites of r-process enhanced stars now found in the halo. This paper includes data gathered with the 6.5 m Magellan Telescopes located at Las Campanas Observatory, Chile.

  9. Fe (III), Co(II), Ni(II), Cu(II) and Zn(II) complexes of schiff bases based-on glycine and phenylalanine: Synthesis, magnetic/thermal properties and antimicrobial activity

    Science.gov (United States)

    Sevgi, Fatih; Bagkesici, Ugur; Kursunlu, Ahmed Nuri; Guler, Ersin

    2018-02-01

    Zinc (II), copper (II), nickel (II), cobalt (II) and iron (III) complexes of Schiff bases (LG, LP) derived from 2-hydroxynaphthaldehyde with glycine and phenylalanine were reported and characterized by 1H NMR, 13C NMR, elemental analyses, melting point, FT-IR, magnetic susceptibility and thermal analyses (TGA). TGA data show that iron and cobalt include to the coordinated water and metal:ligand ratio is 1:2 while the complex stoichiometry for Ni (II), Cu (II) and Zn (II) complexes is 1:1. As expected, Ni (II) and Zn (II) complexes are diamagnetic; Cu (II), Co (II) and Fe (III) complexes are paramagnetic character due to a strong ligand of LG and LP. The LG, LP and their metal complexes were screened for their antimicrobial activities against five Gram-positive (Staphylococcus aureus, Methicillin resistant Staphylococcus aureus (MRSA), Bacillus cereus, Streptococcus mutans and Enterococcus faecalis) and three Gram-negative (Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa) and one fungi (Candida albicans) by using broth microdilution techniques. The activity data show that ligands and their metal complexes exhibited moderate to good activity against Gram-positive bacteria and fungi.

  10. Status of the FRM-II project

    International Nuclear Information System (INIS)

    Boening, K.

    1994-01-01

    The new research reactor FRM-II at Garching near Munich is planned to become a high performance source of slow neutrons in Germany. Its design concept provides for a very compact reactor core cooled by light water and placed within a heavy water moderator tank, where a high thermal neutron flux will be obtained at only 20 MW power. - This paper begins with an overview over some of the essential design features and some more recent design modifications. It then reports on the status of the project, the most important event being a positive decision which the Bavarian State Government has made in January 1993 and which represented a green light for the project to enter the next project phase. Consequently, two official requests have been made by the Technical University of Munich, one for the nuclear licensing of the facility and the other for the so called 'Raumordnungsverfahren'. In this context the final version of the FRM-II safety report has been submitted to the nuclear licensing authority. (author)

  11. DNA damage by the cobalt (II) and zinc (II) complexes of ...

    African Journals Online (AJOL)

    Using the single cell gel electrophoresis method, the tetraazamacrocycle Zn(II) complex (Zn(II)-L) and the tetraazamacrocycle Co(II) complex (Co(II)-L) were investigated focusing on their DNA damage to Tetrahymena thermophila. When the cells were treated with the 0.05, 0.25 and 0.50 mg/ml Zn(II)-L, the tail length ...

  12. Syntheses and spectroscopic properties of mercury(II) and nickel(II ...

    African Journals Online (AJOL)

    Mercury(II) complex, [Hg2(BPTU-2H)Cl2] and nickel(II) complex, [Ni(BPTU-H)2] were prepared by reacting Bis(N-phenylthiourea), BPTU, with mercury(II) chloride and nickel(II) acetate respectively. The complexes were characterized by IR, diffuse reflectance, 1H NMR spectra and elemental analysis. BPTU acts as ...

  13. Solar Type II Radio Bursts and IP Type II Events

    Science.gov (United States)

    Cane, H. V.; Erickson, W. C.

    2005-01-01

    We have examined radio data from the WAVES experiment on the Wind spacecraft in conjunction with ground-based data in order to investigate the relationship between the shocks responsible for metric type II radio bursts and the shocks in front of coronal mass ejections (CMEs). The bow shocks of fast, large CMEs are strong interplanetary (IP) shocks, and the associated radio emissions often consist of single broad bands starting below approx. 4 MHz; such emissions were previously called IP type II events. In contrast, metric type II bursts are usually narrowbanded and display two harmonically related bands. In addition to displaying complete dynamic spectra for a number of events, we also analyze the 135 WAVES 1 - 14 MHz slow-drift time periods in 2001-2003. We find that most of the periods contain multiple phenomena, which we divide into three groups: metric type II extensions, IP type II events, and blobs and bands. About half of the WAVES listings include probable extensions of metric type II radio bursts, but in more than half of these events, there were also other slow-drift features. In the 3 yr study period, there were 31 IP type II events; these were associated with the very fastest CMEs. The most common form of activity in the WAVES events, blobs and bands in the frequency range between 1 and 8 MHz, fall below an envelope consistent with the early signatures of an IP type II event. However, most of this activity lasts only a few tens of minutes, whereas IP type II events last for many hours. In this study we find many examples in the radio data of two shock-like phenomena with different characteristics that occur simultaneously in the metric and decametric/hectometric bands, and no clear example of a metric type II burst that extends continuously down in frequency to become an IP type II event. The simplest interpretation is that metric type II bursts, unlike IP type II events, are not caused by shocks driven in front of CMEs.

  14. Rotation in [C II]-emitting gas in two galaxies at a redshift of 6.8

    Science.gov (United States)

    Smit, Renske; Bouwens, Rychard J.; Carniani, Stefano; Oesch, Pascal A.; Labbé, Ivo; Illingworth, Garth D.; van der Werf, Paul; Bradley, Larry D.; Gonzalez, Valentino; Hodge, Jacqueline A.; Holwerda, Benne W.; Maiolino, Roberto; Zheng, Wei

    2018-01-01

    The earliest galaxies are thought to have emerged during the first billion years of cosmic history, initiating the ionization of the neutral hydrogen that pervaded the Universe at this time. Studying this ‘epoch of reionization’ involves looking for the spectral signatures of ancient galaxies that are, owing to the expansion of the Universe, now very distant from Earth and therefore exhibit large redshifts. However, finding these spectral fingerprints is challenging. One spectral characteristic of ancient and distant galaxies is strong hydrogen-emission lines (known as Lyman-α lines), but the neutral intergalactic medium that was present early in the epoch of reionization scatters such Lyman-α photons. Another potential spectral identifier is the line at wavelength 157.4 micrometres of the singly ionized state of carbon (the [C II] λ = 157.74 μm line), which signifies cooling gas and is expected to have been bright in the early Universe. However, so far Lyman-α-emitting galaxies from the epoch of reionization have demonstrated much fainter [C II] luminosities than would be expected from local scaling relations, and searches for the [C II] line in sources without Lyman-α emission but with photometric redshifts greater than 6 (corresponding to the first billion years of the Universe) have been unsuccessful. Here we identify [C II] λ = 157.74 μm emission from two sources that we selected as high-redshift candidates on the basis of near-infrared photometry; we confirm that these sources are two galaxies at redshifts of z = 6.8540 ± 0.0003 and z = 6.8076 ± 0.0002. Notably, the luminosity of the [C II] line from these galaxies is higher than that found previously in star-forming galaxies with redshifts greater than 6.5. The luminous and extended [C II] lines reveal clear velocity gradients that, if interpreted as rotation, would indicate that these galaxies have similar dynamic properties to the turbulent yet rotation

  15. Evolutionary behaviour of AGN: Investigations on BL Lac objects and Seyfert II galaxies

    Science.gov (United States)

    Beckmann, V.

    2000-12-01

    The evolution and nature of AGN is still one of the enigmatic questions in astrophysics. While large and complete Quasar samples are available, special classes of AGN, like BL Lac objects and Seyfert II galaxies, are still rare objects. In this work I present two new AGN samples. The first one is the HRX-BL Lac survey, resulting in a sample of X-ray selected BL Lac objects. This sample results from 223 BL Lac candidates based on a correlation of X-ray sources with radio sources. The identification of this sample is 98% complete. 77 objects have been identified as BL Lac objects and form the HRX-BL Lac complete sample, the largest homogeneous sample of BL Lac objects existing today. For this sample, redshifts are now known for 62 objects (81 %). In total I present 101 BL Lac objects in the enlarged HRX-BL Lac survey, for which redshift information is available for 84 objects. During the HRX-BL Lac survey I found several objects of special interest. 1ES 1517+656 turned out to be the brightest known BL Lac object in the universe. 1ES 0927+500 could be the first BL Lac object with a line detected in the X-ray region. RX J1211+2242 is probably the the counterpart of the up to now unidentified gamma-ray source 3EG J1212+2304. Additionally I present seven candidates for ultra high frequency peaked BL Lac objects. RX J1054+3855 and RX J1153+3517 are rare high redshift X-ray bright QSO or accreting binary systems with huge magnetic fields. For the BL Lac objects I suggest an unified scenario in which giant elliptical galaxies, formed by merging events of spiral galaxies at z > 2, start as powerful, radio dominated BL Lacs. As the jet gets less powerful, the BL Lacs start to get more X-ray dominated, showing less total luminosities (for z definition to objects with a calcium break up to 40%, but do not support for the HBL the idea of allowing emission lines in the spectra of BL Lac galaxies. A way to find high redshift BL Lac objects might be the identification of faint X

  16. Synthesis and characterization of iron(III), manganese(II), cobalt(II), nickel(II), copper(II) and zinc(II) complexes of salicylidene-N-anilinoacetohydrazone (H2L1) and 2-hydroxy-1-naphthylidene-N-anilinoacetohydrazone (H2L2).

    Science.gov (United States)

    AbouEl-Enein, S A; El-Saied, F A; Kasher, T I; El-Wardany, A H

    2007-07-01

    Salicylidene-N-anilinoacetohydrazone (H(2)L(1)) and 2-hydroxy-1-naphthylidene-N-anilinoacetohydrazone (H(2)L(2)) and their iron(III), manganese(II), cobalt(II), nickel(II), copper(II) and zinc(II) complexes have been synthesized and characterized by IR, electronic spectra, molar conductivities, magnetic susceptibilities and ESR. Mononuclear complexes are formed with molar ratios of 1:1, 1:2 and 1:3 (M:L). The IR studies reveal various modes of chelation. The electronic absorption spectra and magnetic susceptibility measurements show that the iron(III), nickel(II) and cobalt(II) complexes of H(2)L(1) have octahedral geometry. While the cobalt(II) complexes of H(2)L(2) were separated as tetrahedral structure. The copper(II) complexes have square planar stereochemistry. The ESR parameters of the copper(II) complexes at room temperature were calculated. The g values for copper(II) complexes proved that the Cu-O and Cu-N bonds are of high covalency.

  17. Community shift of biofilms developed in a full-scale drinking water distribution system switching from different water sources.

    Science.gov (United States)

    Li, Weiying; Wang, Feng; Zhang, Junpeng; Qiao, Yu; Xu, Chen; Liu, Yao; Qian, Lin; Li, Wenming; Dong, Bingzhi

    2016-02-15

    The bacterial community of biofilms in drinking water distribution systems (DWDS) with various water sources has been rarely reported. In this research, biofilms were sampled at three points (A, B, and C) during the river water source phase (phase I), the interim period (phase II) and the reservoir water source phase (phase III), and the biofilm community was determined using the 454-pyrosequencing method. Results showed that microbial diversity declined in phase II but increased in phase III. The primary phylum was Proteobacteria during three phases, while the dominant class at points A and B was Betaproteobacteria (>49%) during all phases, but that changed to Holophagae in phase II (62.7%) and Actinobacteria in phase III (35.6%) for point C, which was closely related to its water quality. More remarkable community shift was found at the genus level. In addition, analysis results showed that water quality could significantly affect microbial diversity together, while the nutrient composition (e.g. C/N ration) of the water environment might determine the microbial community. Furthermore, Mycobacterium spp. and Pseudomonas spp. were detected in the biofilm, which should give rise to attention. This study revealed that water source switching produced substantial impact on the biofilm community. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. CHANDRA ACIS SURVEY OF X-RAY POINT SOURCES IN NEARBY GALAXIES. II. X-RAY LUMINOSITY FUNCTIONS AND ULTRALUMINOUS X-RAY SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Song; Qiu, Yanli; Liu, Jifeng [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Bregman, Joel N., E-mail: songw@bao.ac.cn, E-mail: jfliu@bao.ac.cn [University of Michigan, Ann Arbor, MI 48109 (United States)

    2016-09-20

    Based on the recently completed Chandra /ACIS survey of X-ray point sources in nearby galaxies, we study the X-ray luminosity functions (XLFs) for X-ray point sources in different types of galaxies and the statistical properties of ultraluminous X-ray sources (ULXs). Uniform procedures are developed to compute the detection threshold, to estimate the foreground/background contamination, and to calculate the XLFs for individual galaxies and groups of galaxies, resulting in an XLF library of 343 galaxies of different types. With the large number of surveyed galaxies, we have studied the XLFs and ULX properties across different host galaxy types, and confirm with good statistics that the XLF slope flattens from lenticular ( α ∼ 1.50 ± 0.07) to elliptical (∼1.21 ± 0.02), to spirals (∼0.80 ± 0.02), to peculiars (∼0.55 ± 0.30), and to irregulars (∼0.26 ± 0.10). The XLF break dividing the neutron star and black hole binaries is also confirmed, albeit at quite different break luminosities for different types of galaxies. A radial dependency is found for ellipticals, with a flatter XLF slope for sources located between D {sub 25} and 2 D {sub 25}, suggesting the XLF slopes in the outer region of early-type galaxies are dominated by low-mass X-ray binaries in globular clusters. This study shows that the ULX rate in early-type galaxies is 0.24 ± 0.05 ULXs per surveyed galaxy, on a 5 σ confidence level. The XLF for ULXs in late-type galaxies extends smoothly until it drops abruptly around 4 × 10{sup 40} erg s{sup −1}, and this break may suggest a mild boundary between the stellar black hole population possibly including 30 M {sub ⊙} black holes with super-Eddington radiation and intermediate mass black holes.

  19. Pecan nutshell as biosorbent to remove Cu(II), Mn(II) and Pb(II) from aqueous solutions.

    Science.gov (United States)

    Vaghetti, Julio C P; Lima, Eder C; Royer, Betina; da Cunha, Bruna M; Cardoso, Natali F; Brasil, Jorge L; Dias, Silvio L P

    2009-02-15

    In the present study we reported for the first time the feasibility of pecan nutshell (PNS, Carya illinoensis) as an alternative biosorbent to remove Cu(II), Mn(II) and Pb(II) metallic ions from aqueous solutions. The ability of PNS to remove the metallic ions was investigated by using batch biosorption procedure. The effects such as, pH, biosorbent dosage on the adsorption capacities of PNS were studied. Four kinetic models were tested, being the adsorption kinetics better fitted to fractionary-order kinetic model. Besides that, the kinetic data were also fitted to intra-particle diffusion model, presenting three linear regions, indicating that the kinetics of adsorption should follow multiple sorption rates. The equilibrium data were fitted to Langmuir, Freundlich, Sips and Redlich-Peterson isotherm models. Taking into account a statistical error function, the data were best fitted to Sips isotherm model. The maximum biosorption capacities of PNS were 1.35, 1.78 and 0.946mmolg(-1) for Cu(II), Mn(II) and Pb(II), respectively.

  20. Physico - chemical investigation on Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO2+2 and VO+2 ions-O-(-N-3,5-dichloro-α-pyridone imino)

    International Nuclear Information System (INIS)

    Mathur, Praveen; Trivedi, Pradeep; Mehta, R.K.

    1983-01-01

    Studies on the interaction of newly synthesised ligand, O-(N-3, 5-dichloro-α-pyridone imino) benzene sulphonic acid (H 2 PB) with Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO 2 +2 and VO +2 have been carried out potentiometrically. Many physico-chemical studies on thermodynamics, elemental analysis, molecular weight, magnetic moment, conductance, electronic and IR spectra have also been made on the solid chelates and their adducts. The dissociation constants of H 2 PB and stabilities of its bivalent chelates have been evaluated potentiometrically at 25deg, 35deg and 45degC in aqueous medium (0.01M, 0.05M and 0.1M NaClO 4 ) by Bjerrum's method. The stability sequence is in agreement with the Irving-William's rule. (author)

  1. Performance enhancement of Ge-on-Insulator tunneling FETs with source junctions formed by low-energy BF2 ion implantation

    Science.gov (United States)

    Katoh, Takumi; Matsumura, Ryo; Takaguchi, Ryotaro; Takenaka, Mitsuru; Takagi, Shinichi

    2018-04-01

    To clarify the process of formation of source regions of high-performance Ge n-channel tunneling field-effect transistors (TFETs), p+-n junctions formed by low-energy ion implantation (I/I) of BF2 atoms are characterized. Here, the formation of p+-n junctions with steep B profiles and low junction leakage is a key issue. The steepness of 5.7 nm/dec in profiles of B implanted into Ge is obtained for BF2 I/I at 3 keV with a dose of 4 × 1014 cm-2. Ge-on-insulator (GOI) n-TFETs with the source tunnel junctions formed by low-energy B and BF2 I/I are fabricated on GOI substrates and the device operation is confirmed. Although the performance at room temperature is significantly degraded by the source junction leakage current, an I on/I off ratio of 105 and the minimum sub-threshold swing (S.S.) of 130 mV/dec are obtained at 10 K. It is found that GOI n-TFETs with steeper B profiles formed by BF2 I/I have led to higher on current and a lower sub-threshold slope, demonstrating the effectiveness of steep B profiles in enhancing the GOI TFET performance.

  2. Unsaturated b-ketoesters and their Ni(II, Cu(II and Zn(II complexes

    Directory of Open Access Journals (Sweden)

    MUHAMMED BASHEER UMMATHUR

    2009-03-01

    Full Text Available A new series of b-ketoesters in which the keto group is attached to the olefinic linkage were synthesized by the reaction of methyl acetoacetate and aromatic aldehydes under specified conditions. The existence of these compounds predominantly in the intramolecularly hydrogen bonded enol form was well demonstrated from their IR, 1H-NMR and mass spectral data. Details on the formation of their [ML2] complexes with Ni(II, Cu(II and Zn(II and the nature of the bonding are discussed on the basis of analytical and spectral data.

  3. Room temperature femtosecond X-ray diffraction of photosystem II microcrystals

    Science.gov (United States)

    Kern, Jan; Alonso-Mori, Roberto; Hellmich, Julia; Tran, Rosalie; Hattne, Johan; Laksmono, Hartawan; Glöckner, Carina; Echols, Nathaniel; Sierra, Raymond G.; Sellberg, Jonas; Lassalle-Kaiser, Benedikt; Gildea, Richard J.; Glatzel, Pieter; Grosse-Kunstleve, Ralf W.; Latimer, Matthew J.; McQueen, Trevor A.; DiFiore, Dörte; Fry, Alan R.; Messerschmidt, Marc; Miahnahri, Alan; Schafer, Donald W.; Seibert, M. Marvin; Sokaras, Dimosthenis; Weng, Tsu-Chien; Zwart, Petrus H.; White, William E.; Adams, Paul D.; Bogan, Michael J.; Boutet, Sébastien; Williams, Garth J.; Messinger, Johannes; Sauter, Nicholas K.; Zouni, Athina; Bergmann, Uwe; Yano, Junko; Yachandra, Vittal K.

    2012-01-01

    Most of the dioxygen on earth is generated by the oxidation of water by photosystem II (PS II) using light from the sun. This light-driven, four-photon reaction is catalyzed by the Mn4CaO5 cluster located at the lumenal side of PS II. Various X-ray studies have been carried out at cryogenic temperatures to understand the intermediate steps involved in the water oxidation mechanism. However, the necessity for collecting data at room temperature, especially for studying the transient steps during the O–O bond formation, requires the development of new methodologies. In this paper we report room temperature X-ray diffraction data of PS II microcrystals obtained using ultrashort (< 50 fs) 9 keV X-ray pulses from a hard X-ray free electron laser, namely the Linac Coherent Light Source. The results presented here demonstrate that the ”probe before destroy” approach using an X-ray free electron laser works even for the highly-sensitive Mn4CaO5 cluster in PS II at room temperature. We show that these data are comparable to those obtained in synchrotron radiation studies as seen by the similarities in the overall structure of the helices, the protein subunits and the location of the various cofactors. This work is, therefore, an important step toward future studies for resolving the structure of the Mn4CaO5 cluster without any damage at room temperature, and of the reaction intermediates of PS II during O–O bond formation. PMID:22665786

  4. Synthesis, spectral, thermal and antimicrobial studies on cobalt(II), nickel(II), copper(II), zinc(II) and palladium(II) complexes containing thiosemicarbazone ligand

    Science.gov (United States)

    El-Sawaf, Ayman K.; El-Essawy, Farag; Nassar, Amal A.; El-Samanody, El-Sayed A.

    2018-04-01

    The coordination characteristic of new N4-morpholinyl isatin-3-thiosemicarbazone (HL) towards Co(II), Ni(II), Cu(II), Zn(II) and Pd(II) has been studies. The structures of the complexes were described by elemental analyses, molar conductivity, magnetic, thermal and spectral (IR, UV-Vis, 1H and 13C NMR and ESR) studies. On the basis of analytical and spectral studies the ligand behaves as monobasic tridentate ONS donor forming two five membered rings towards cobalt, copper and palladium and afforded complexes of the kind [M(L)X], (Mdbnd Co, Cu or Pd; Xdbnd Cl, Br or OAc). Whereas the ligand bound to NiCl2 as neutral tridentate ONS donor and with ZnCl2 as neutral bidentate NS donor. The newly synthesized thiosemicarbazone ligand and some of its complexes were examined for antimicrobial activity against 2 gram negative bacterial strains (Escherichia coli Pseudomonas and aeruginosa), 2 gram positive bacterial strains (Streptococcus pneumoniae and Staphylococcus aureus)} and two Pathogenic fungi (Aspergillus fumigatus and Candida albicans). All metal complexes possess higher antimicrobial activity comparing with the free thiosemicarbazone ligand. The high potent activities of the complexes may arise from the coordination and chelation, which tends to make metal complexes act as more controlling and potent antimicrobial agents, thus hindering the growing of the microorganisms. The antimicrobial results also show that copper bromide complex is better antimicrobial agent as compared to the Schiff base and its metal complexes.

  5. Towards adiabatic waveforms for inspiral into Kerr black holes. II. Dynamical sources and generic orbits

    International Nuclear Information System (INIS)

    Sundararajan, Pranesh A.; Hughes, Scott A.; Khanna, Gaurav; Drasco, Steve

    2008-01-01

    This is the second in a series of papers whose aim is to generate adiabatic gravitational waveforms from the inspiral of stellar-mass compact objects into massive black holes. In earlier work, we presented an accurate (2+1)D finite-difference time-domain code to solve the Teukolsky equation, which evolves curvature perturbations near rotating (Kerr) black holes. The key new ingredient there was a simple but accurate model of the singular source term based on a discrete representation of the Dirac-delta function and its derivatives. Our earlier work was intended as a proof of concept, using simple circular, equatorial geodesic orbits as a test bed. Such a source is effectively static, in that the smaller body remains at the same coordinate radius and orbital inclination over an orbit. (It of course moves through axial angle, but we separate that degree of freedom from the problem. Our numerical grid has only radial, polar, and time coordinates.) We now extend the time-domain code so that it can accommodate dynamic sources that move on a variety of physically interesting world lines. We validate the code with extensive comparison to frequency-domain waveforms for cases in which the source moves along generic (inclined and eccentric) bound geodesic orbits. We also demonstrate the ability of the time-domain code to accommodate sources moving on interesting nongeodesic worldlines. We do this by computing the waveform produced by a test mass following a kludged inspiral trajectory, made of bound geodesic segments driven toward merger by an approximate radiation loss formula.

  6. Equilibrium and kinetic studies of Pb(II, Cd(II and Zn(II sorption by Lagenaria vulgaris shell

    Directory of Open Access Journals (Sweden)

    Mitić-Stojanović Dragana-Linda

    2012-01-01

    Full Text Available The sorption of lead, cadmium and zinc ions from aqueous solution by Lagenaria vulgaris shell biosorbent (LVB in batch system was investigated. The effect of relevant parameters such as contact time, biosorbent dosage and initial metal ions concentration was evaluated. The Pb(II, Cd(II and Zn(II sorption equilibrium (when 98% of initial metal ions were sorbed was attained within 15, 20 and 25 min, respectively. The pseudo first, pseudo-second order, Chrastil’s and intra-particle diffusion models were used to describe the kinetic data. The experimental data fitted the pseudo-second order kinetic model and intra-particle diffusion model. Removal efficiency of lead(II, cadmium(II and zinc(II ions rapidly increased with increasing biosorbent dose from 0.5 to 8.0 g dm-3. Optimal biosorbent dose was set to 4.0 g dm-3. An increase in the initial metal concentration increases the sorption capacity. The sorption data of investigated metal ions are fitted to Langmuir, Freundlich and Temkin isotherm models. Langmuir model best fitted the equilibrium data (r2 > 0.99. Maximal sorption capacities of LVB for Pb(II, Cd(II and Zn(II at 25.0±0.5°C were 0.130, 0.103 and 0.098 mM g-1, respectively. The desorption experiments showed that the LVB could be reused for six cycles with a minimum loss of the initial sorption capacity.

  7. The TRUPACT-II Matrix Depleton Program

    International Nuclear Information System (INIS)

    Connolly, M.J.; Djordjevic, S.M.; Loehr, C.A.; Smith, M.C.; Banjac, V.; Lyon, W.F.

    1995-01-01

    Contact-handled transuranic (CH-TRU) wastes will be shipped and disposed at the Waste Isolation Pilot Plant (WIPP) repository in the Transuranic Package Transporter-II (TRUPACT-II) shipping package. A primary transportation requirement for the TRUPACT-II is that the concentration of potentially flammable gases (i.e., hydrogen and methane) must not exceed 5 percent by volume in the package or the payload during a 60-day shipping period. Decomposition of waste materials by radiation, or radiolysis, is the predominant mechanism of gas generation during transport. The gas generation potential of a target waste material is characterized by a G-value, which is the number of molecules of gas generated per 100 eV of ionizing radiation absorbed by the target material. To demonstrate compliance with the flammable gas concentration requirement, theoretical worst-case calculations were performed to establish allowable wattage (decay heat) limits for waste containers. The calculations were based on the G-value for the waste material with the highest potential for flammable gas generation. The calculations also made no allowances for decreases of the G-value over time due to matrix depletion phenomena that have been observed by many experimenters. Matrix depletion occurs over time when an alpha-generating source particle alters the target material (by evaporation, reaction, or decomposition) into a material of lower gas generating potential. The net effect of these alterations is represented by the ''effective G-value.''

  8. Recovery of Cd(II), Co(II) and Ni(II) from Chloride Medium by Solvent Extraction Using CYANEX 923 and CYANEX 272 I

    International Nuclear Information System (INIS)

    Ahmed, M.; El Dessouky, S.I.; El-Nadi, Y.A.; Daoud, J.A.; Saad, E.A.

    2008-01-01

    The paper aims to study the extraction and separation of Cd(II), Co(II) and Ni(II) from their mixtures in hydrochloric acid medium with CYANEX 923 in kerosene. Preliminary investigations showed that only Cd(II) is extracted with CYANEX 923 while Co(II) and Ni(II) are not extracted. Different parameters affecting the extraction of Cd(II) with CYANEX 923 such as hydrochloric acid, hydrogen ion, extractant and metal concentrations, temperature investigations were also investigated. The stoichiometry of the extracted metal species investigated was found to be HCdCl 3 . 2 CYANEX 923. The stripping of the extracted Cd(II) species is obtained with 0.1 M HCl solution. Co(II) was found to be extracted with CYANEX 272 at ph 5.8 leaving Ni(II) in the solution. A developed process for the sequential of Cd(II), Co(II) and Ni(II) from their mixture in hydrochloric acid medium is proposed

  9. Brain source localization using a fourth-order deflation scheme

    Science.gov (United States)

    Albera, Laurent; Ferréol, Anne; Cosandier-Rimélé, Delphine; Merlet, Isabel; Wendling, Fabrice

    2008-01-01

    A high resolution method for solving potentially ill-posed inverse problems is proposed. This method named FO-D-MUSIC allows for localization of brain current sources with unconstrained orientations from surface electro- or magnetoencephalographic data using spherical or realistic head geometries. The FO-D-MUSIC method is based on i) the separability of the data transfer matrix as a function of location and orientation parameters, ii) the Fourth Order (FO) virtual array theory, and iii) the deflation concept extended to FO statistics accounting for the presence of potentially but not completely statistically dependent sources. Computer results display the superiority of the FO-D-MUSIC approach in different situations (very closed sources, small number of electrodes, additive Gaussian noise with unknown spatial covariance, …) compared to classical algorithms. PMID:18269984

  10. Kinetic modeling of particle dynamics in H− negative ion sources (invited)

    International Nuclear Information System (INIS)

    Hatayama, A.; Shibata, T.; Nishioka, S.; Ohta, M.; Yasumoto, M.; Nishida, K.; Yamamoto, T.; Miyamoto, K.; Fukano, A.; Mizuno, T.

    2014-01-01

    Progress in the kinetic modeling of particle dynamics in H − negative ion source plasmas and their comparisons with experiments are reviewed, and discussed with some new results. Main focus is placed on the following two topics, which are important for the research and development of large negative ion sources and high power H − ion beams: (i) Effects of non-equilibrium features of EEDF (electron energy distribution function) on H − production, and (ii) extraction physics of H − ions and beam optics

  11. The type II collagen fragments Helix-II and CTX-II reveal different enzymatic pathways of human cartilage collagen degradation

    DEFF Research Database (Denmark)

    Charni-Ben Tabassi, N; Desmarais, S; Jensen, Anne-Christine Bay

    2008-01-01

    human recombinant cathepsins (Cats) and matrix-metalloproteases (MMPs). Next, we analyzed the spontaneous release of Helix-II and CTX-II from cartilage sections of patients with knee OA who were immediately deep frozen after joint replacement to preserve endogenous enzyme activity until assay. Cartilage....... Cat D was unable to digest intact cartilage. MMPs-1, -3, -7, -9, and -13 efficiently released CTX-II, but only small amount of Helix-II. Neither CTX-II nor Helix-II alone was able to reflect accurately the collagenolytic activity of Cats and MMPs as reflected by the release of hydroxyproline. In OA...

  12. Reproducing a Prospective Clinical Study as a Computational Retrospective Study in MIMIC-II.

    Science.gov (United States)

    Kury, Fabrício S P; Huser, Vojtech; Cimino, James J

    2015-01-01

    In this paper we sought to reproduce, as a computational retrospective study in an EHR database (MIMIC-II), a recent large prospective clinical study: the 2013 publication, by the Japanese Association for Acute Medicine (JAAM), about disseminated intravascular coagulation, in the journal Critical Care (PMID: 23787004). We designed in SQL and Java a set of electronic phenotypes that reproduced the study's data sampling, and used R to perform the same statistical inference procedures. All produced source code is available online at https://github.com/fabkury/paamia2015. Our program identified 2,257 eligible patients in MIMIC-II, and the results remarkably agreed with the prospective study. A minority of the needed data elements was not found in MIMIC-II, and statistically significant inferences were possible in the majority of the cases.

  13. Operation experience of the UE44 fixed gap APPLE II at SLS

    International Nuclear Information System (INIS)

    Schmidt, T; Calvi, M; Schmitt, T; Strocov, V N; Zimoch, D

    2013-01-01

    All soft x-ray beamlines at the Swiss Light Source (SLS) are served with variable polarization from APPLE II [1] type and electromagnetic undulators. Three APPLE II type undulators are used: a twin and a single standard APPLE II (UE56 and UE54) and a fixed gap APPLE II (UE44) which follows the adjustable-phase undulator approach by R. Carr [2], [3]. The demand to rotate the linear polarization vector from 0 – 180° required all four magnet arrays to be shiftable. This opened the possibility to also vary the energy by a suitable shift of the magnet arrays with a simplified support structure lacking in any gap drive system [4], [5]. The current photon beam quality in linear and circular mode and the pros and cons of the operation of the UE44 will be discussed, namely the underestimated influence of gradients in the complex field distribution. As a consequence the spectra are degraded, but can be recovered by use of distributed coils or by a simple change in the operation mode.

  14. Thermal, spectral, magnetic and biological studies of thiosemicarbazones complexes with metal ions: Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO2(VI)

    International Nuclear Information System (INIS)

    Mashaly, M.M.; Seleem, H.S.; El-Behairy, M.A.; Habib, H.A.

    2004-01-01

    Thiosemicarbazones ligands, isatin-3-thiosemicarbazone(HIT) and N-acetylisatin-3-thiosemicarbazone (HAIT), which have tridentate ONN coordinating sites were prepared. The complexes of both ligands with Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO 2 (VI) ions were isolated. The ligands and their metal complexes were characterized by elemental analysis, IR, UV-Vis and mass spectra, also by conductance, magnetic moment and TG-DSC measurements. All the transition metal complexes have octahedral configurations, except Cu-complexes which have planar geometry and the UO 2 (VI) complexes which have coordination number 8 and may acquire the distorted dodecahedral geometry. Thermal studies explored the possibility of obtaining new complexes. Inversion from octahedral to square-planar configuration occurred upon heating the parent Ni-HIAT complex to form the corresponding pyrolytic product. The antifungal activity against the tested organisms showed that some metal complexes enhanced the activity with respect to the parent ligands. (author)

  15. Competitive adsorption of Pb(II), Cu(II), and Zn(II) ions onto hydroxyapatite-biochar nanocomposite in aqueous solutions

    Science.gov (United States)

    Wang, Yu-Ying; Liu, Yu-Xue; Lu, Hao-Hao; Yang, Rui-Qin; Yang, Sheng-Mao

    2018-05-01

    A hydroxyapatite-biochar nanocomposite (HAP-BC) was successfully fabricated and its physicochemical properties characterized. The analyses showed that HAP nanoparticles were successfully loaded on the biochar surface. The adsorption of Pb(II), Cu(II), and Zn(II) by HAP-BC was systematically studied in single and ternary metal systems. The results demonstrated that pH affects the adsorption of heavy metals onto HAP-BC. Regarding the adsorption kinetics, the pseudo-second-order model showed the best fit for all three heavy metal ions on HAP-BC. In both single and ternary metal ion systems, the adsorption isotherm of Pb(II) by HAP-BC followed Langmuir model, while those of Cu(II) and Zn(II) fitted well with Freundlich model. The maximum adsorption capacity for each tested metal by HAP-BC was higher than that of pristine rice straw biochar (especially for Pb(II)) or those of other reported adsorbents. Therefore, HAP-BC could explore as a new material for future application in heavy metal removal.

  16. Biosorption characteristics of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions by Chara sp. and Cladophora sp.

    Science.gov (United States)

    Elmaci, Ayşe; Yonar, Taner; Ozengin, Nihan

    2007-09-01

    The aim of this research was to expose individual removals of copper, chromium, nickel, and lead from aqueous solutions via biosorption using nonliving algae species, Chara sp. and Cladophora sp. Optimum pH values for biosorption of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions were determined to be 6, 7, 7, and 3 for Cladophora sp. and 5, 3, 5, and 4 for Chara sp. respectively. Maximum adsorption capacities of Chara sp. [10.54 for chromium (III) and 61.72 for lead (II)] and Cladophora sp. [6.59 for chromium (III) and 16.75 and 23.25 for lead (II)] for chromium (III) and lead (II) are similar. On the other hand, copper (II) and nickel (II) biosorption capacity of Cladophora sp. [14.28 for copper (II) and 16.75 for nickel (II)] is greater than Chara sp. [6.506 for copper (II) and 11.76 for nickel (II)]. Significantly high correlation coefficients indicated for the Langmuir adsorption isotherm models can be used to describe the equilibrium behavior of copper, chromium, nickel, and lead adsorption onto Cladophora sp. and Chara sp.

  17. Governance of Open Source Software Foundations: Who Holds the Power?

    Directory of Open Access Journals (Sweden)

    Ludovico Prattico

    2012-12-01

    Full Text Available The research reported in this article attempts to discover who holds the power in open source software foundations through the analysis of governance documents. Artificial neural network analysis is used to analyse the content of the bylaws of six open source foundations (Apache, Eclipse, GNOME, Plone, Python, and SPI for the purpose of identifying power structures. Results of the research suggest that: i the actions of an open source software foundation are centered around one of three groups: Members, Chairman/President/Executive Director, and Board of Directors; ii in only one of the six foundations is the Board of Directors responsible for both the community and the product; and iii artificial neural network analysis of the content of bylaws provides unbiased insights of the power structure of open source software foundations. These results may prove useful to those who contribute to open source foundations and use their products and services.

  18. DNA damage by the cobalt (II) and zinc (II) complexes of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-03

    Sep 3, 2008 ... distributed in grade 3. The results indicated that Co(II)-L induced a relatively high level of DNA damage in comparison with the level of damage induced by Zn(II)-L. Key words: Tetraazamacrocycle Zn(II) complex, tetraazamacrocycle Co(II) complex, Tetrahymena thermophila, DNA damage, the comet assay.

  19. Determination of delayed neutrons source in the frequency domain based on in-pile oscillation measurements

    International Nuclear Information System (INIS)

    Yedvab, Y.; Reiss, I.; Bettan, M.; Harari, R.; Grober, A.; Ettedgui, H.; Caspi, E. N.

    2006-01-01

    A method for determining delayed neutrons source in the frequency domain based on measuring power oscillations in a non-critical reactor is presented. This method is unique in the sense that the delayed neutrons source is derived from the dynamic behavior of the reactor, which serves as the measurement system. An algorithm for analyzing power oscillation measurements was formulated, which avoids the need for a multi-parameter non-linear fit process used by other methods. Using this algorithm results of two sets of measurements performed in IRR-I and IRR-II (Israeli Research Reactors I and II) are presented. The agreement between measured values from both reactors and calculated values based on Keepin (and JENDL-3.3) group parameters is very good. (authors)

  20. Neutron stars as X-ray burst sources. II. Burst energy histograms and why they burst

    International Nuclear Information System (INIS)

    Baan, W.A.

    1979-01-01

    In this work we explore some of the implications of a model for X-ray burst sources where bursts are caused by Kruskal-Schwarzschild instabilities at the magnetopause of an accreting and rotating neutron star. A number of simplifying assumptions are made in order to test the model using observed burst-energy histograms for the rapid burster MXB 1730--335. The predicted histograms have a correct general shape, but it appears that other effects are important as well, and that mode competition, for instance, may suppress the histograms at high burst energies. An explanation is ventured for the enhancement in the histogram at the highest burst energies, which produces the bimodal shape in high accretion rate histograms. Quantitative criteria are given for deciding when accreting neutron stars are steady sources or burst sources, and these criteria are tested using the X-ray pulsars

  1. Identification of fecal contamination sources in water using host-associated markers.

    Science.gov (United States)

    Krentz, Corinne A; Prystajecky, Natalie; Isaac-Renton, Judith

    2013-03-01

    In British Columbia, Canada, drinking water is tested for total coliforms and Escherichia coli, but there is currently no routine follow-up testing to investigate fecal contamination sources in samples that test positive for indicator bacteria. Reliable microbial source tracking (MST) tools to rapidly test water samples for multiple fecal contamination markers simultaneously are currently lacking. The objectives of this study were (i) to develop a qualitative MST tool to identify fecal contamination from different host groups, and (ii) to evaluate the MST tool using water samples with evidence of fecal contamination. Singleplex and multiplex polymerase chain reaction (PCR) were used to test (i) water from polluted sites and (ii) raw and drinking water samples for presence of bacterial genetic markers associated with feces from humans, cattle, seagulls, pigs, chickens, and geese. The multiplex MST assay correctly identified suspected contamination sources in contaminated waterways, demonstrating that this test may have utility for heavily contaminated sites. Most raw and drinking water samples analyzed using singleplex PCR contained at least one host-associated marker. Singleplex PCR was capable of detecting host-associated markers in small sample volumes and is therefore a promising tool to further analyze water samples submitted for routine testing and provide information useful for water quality management.

  2. Synthesis and characterization of nickel(II), cobalt(II), copper(II), manganese(II), zinc(II), zirconium(IV), dioxouranium(VI) and dioxomolybdenum(VI) complexes of a new Schiff base derived from salicylaldehyde and 5-methylpyrazole-3-carbohydrazide

    International Nuclear Information System (INIS)

    Syamal, A.; Maurya, M.R.

    1986-01-01

    Synthesis of a new Schiff base derived from salicylaldehyde and 5-methylpyrazole-3-carbohydrazide, and its coordination compounds with nickel(II), cobalt(II), copper(II), manganese(II), zinc(II), zirconium(IV), dioxouranium(VI) and dioxomolybdenum(VI) are described. The ligand and the complexes have been characterized on the basis of analytical, conductance, molecular weight, i.r., electronic and n.m.r. spectra and magnetic susceptibility measurements. The stoichiometries of the complexes are represented as NiL . 3H 2 O, CoL . 2H 2 O, CuL, MnL . 2H 2 O, ZnL . H 2 O, Zr(OH) 2 (LH) 2 , Zr(OH) 2 L . 2MeOH, UO 2 L . MeOH and MoO 2 L . MeOH (where LH 2 =Schiff base). The copper(II) complex shows a subnormal magnetic moment due to antiferromagnetic exchange interaction while the nickel(II), cobalt(II) and manganese(II) complexes show normal magnetic moments at room temperature. The i.r. and n.m.r. spectral studies show that the Schiff base behaves as a dibasic and tridentate ligand coordinating through the deprotonated phenolic oxygen, enolic oxygen and azomethine nitrogen. (orig.)

  3. Levels of Cd (II, Mn (II, Pb (II, Cu (II, and Zn (II in Common Buzzard (Buteo buteo from Sicily (Italy by Derivative Stripping Potentiometry

    Directory of Open Access Journals (Sweden)

    P. Licata

    2010-01-01

    Full Text Available The purpose of this study was to determine the concentrations of heavy metals (Cd, Pb, Cu, Mn, and Zn in different organs (liver, kidney, muscle, lung, skin, and feathers of buzzards (Buteo buteo, utilized as a “biological indicator” for environmental contamination, from different areas of Sicily and to investigate the relationships between birds sex, age, and weight and metal levels in these samples. All samples of common buzzards were collected at the “Recovery Center of Wild Fauna” of Palermo, through the Zooprophilactic Institute. Potentiometric stripping analysis (PSA was used to determine the content of Cd(II, Cu(II, Mn(II, Pb(II, and Zn(II in bird tissues. For toxic metals, the highest levels of Pb were in liver and those of Cd in lung; Zn levels were higher than Cu and Mn in all tissues analyzed. The concentrations in liver, lung, kidney, and muscle could be considered as an indicative of chronic exposure to metals while the presence of metals in skin could be consequential to storing and elimination processes. The found concentrations of metals in the studied matrices required a highly sensitive method for their determination and a simple sample preparation procedure, and the proposed method was well suited for this purpose.

  4. Complexes cobalt(II, zinc(II and copper(II with some newly synthesized benzimidazole derivatives and their antibacterial activity

    Directory of Open Access Journals (Sweden)

    S. O. PODUNAVAC-KUZMANOVIC

    1999-05-01

    Full Text Available The preparation and properties of some complexes of cobalt(II, zinc(II and copper(II with several newly synthesized benzimidazole derivatives (L are reported. The complexes, of the general formula [MCl2L2] (M=Co(II, Zn(II and [CuCl2L(H2O], have a tetrahedral structure. The complexes were characterized by elemental analysis, molar conductivity, magnetic susceptibility measurements, IR and absorption electronic spectra. The antibacterial activitiy of the benzimidazoles and their complexes was evaluated against Erwinia carotovora subsp. carotovora and Erwinia amylovora. The complexes were found to be more toxic than the ligands.

  5. Quantification of severe accident source terms of a Westinghouse 3-loop plant

    International Nuclear Information System (INIS)

    Lee Min; Ko, Y.-C.

    2008-01-01

    Integrated severe accident analysis codes are used to quantify the source terms of the representative sequences identified in PSA study. The characteristics of these source terms depend on the detail design of the plant and the accident scenario. A historical perspective of radioactive source term is provided. The grouping of radionuclides in different source terms or source term quantification tools based on TID-14844, NUREG-1465, and WASH-1400 is compared. The radionuclides release phenomena and models adopted in the integrated severe accident analysis codes of STCP and MAAP4 are described. In the present study, the severe accident source terms for risk quantification of Maanshan Nuclear Power Plant of Taiwan Power Company are quantified using MAAP 4.0.4 code. A methodology is developed to quantify the source terms of each source term category (STC) identified in the Level II PSA analysis of the plant. The characteristics of source terms obtained are compared with other source terms. The plant analyzed employs a Westinghouse designed 3-loop pressurized water reactor (PWR) with large dry containment

  6. Micellar effect on metal-ligand complexes of Co(II, Ni(II, Cu(II and Zn(II with citric acid

    Directory of Open Access Journals (Sweden)

    Nageswara Rao Gollapalli

    2009-12-01

    Full Text Available Chemical speciation of citric acid complexes of Co(II, Ni(II, Cu(II and Zn(II was investigated pH-metrically in 0.0-2.5% anionic, cationic and neutral micellar media. The primary alkalimetric data were pruned with SCPHD program. The existence of different binary species was established from modeling studies using the computer program MINIQUAD75. Alkalimetric titrations were carried out in different relative concentrations (M:L:X = 1:2:5, 1:3:5, 1:5:3 of metal (M to citric acid. The selection of best chemical models was based on statistical parameters and residual analysis. The species detected were MLH, ML2, ML2H and ML2H2. The trend in variation of stability constants with change in mole fraction of the medium is explained on the basis of electrostatic and non-electrostatic forces. Distributions of the species with pH at different compositions of micellar media are also presented.

  7. Expansion design for a Laboratory of Radioactive Sources Handling type II, class B; Diseno de ampliacion para un Laboratorio de Manejo de Fuentes Radiactivas tipo II, clase B

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez S, P. S.

    2014-07-01

    This work presents the expansion design of the Radioactive Wastes Research Laboratory (RWRL) installation authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico) as type II class C, to manage 40 different radionuclides, approximately. The RWRL has 4 areas at the present time: a laboratory of instrumental analysis, one of radioactive material processes, other of counting and a chemical reagents stock, which is not integrated to the operation license of the RWRL. With the purpose of expanding the operation license of the RWRL to an installation type II class B, to manage until 370 MBq of high radio toxicity radionuclides, is presented in this work an expansion proposal of the RWRL. The expansion proposal is based in: (1) the Mexican Nuclear Standard NOM-027-Nucl-1996 for installations type II class B, (2) the current distribution of water, light, electricity, extraction, gas, air and vacuum services of RWRL, and (3) the available areas inside the building that the RWRL occupies. The proposal contemplates the creation of additional new areas for RWRL: 3 laboratories, 2 dressing rooms, 2 bathrooms and 2 warehouses, one for radioactive materials and another for reagents chemical radiologically inactive. Architectural, electric, hydraulic, extraction and gas planes corresponding to the expansion of RWRL were realized. Inside the proposal the budget required to carry out the mentioned expansion is also presented. (Author)

  8. Investigation of the polarization state of dual APPLE-II undulators

    International Nuclear Information System (INIS)

    Hand, Matthew; Wang, Hongchang; Dhesi, Sarnjeet S.; Sawhney, Kawal

    2016-01-01

    Complete polarization analysis of the photon beam produced by a dual APPLE-II undulator configuration using a multilayer-based soft X-ray polarimeter is given. The use of an APPLE II undulator is extremely important for providing a high-brilliance X-ray beam with the capability to switch between various photon beam polarization states. A high-precision soft X-ray polarimeter has been used to systematically investigate the polarization characteristics of the two helical APPLE II undulators installed on beamline I06 at Diamond Light Source. A simple data acquisition and processing procedure has been developed to determine the Stokes polarization parameters for light polarized at arbitrary linear angles emitted from a single undulator, and for circularly polarized light emitted from both undulators in conjunction with a single-period undulator phasing unit. The purity of linear polarization is found to deteriorate as the polarization angle moves away from the horizontal and vertical modes. Importantly, a negative correlation between the degree of circular polarization and the photon flux has been found when the phasing unit is used

  9. Investigation of the polarization state of dual APPLE-II undulators

    Energy Technology Data Exchange (ETDEWEB)

    Hand, Matthew; Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Dhesi, Sarnjeet S.; Sawhney, Kawal [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, OX11 0DE (United Kingdom)

    2016-01-01

    Complete polarization analysis of the photon beam produced by a dual APPLE-II undulator configuration using a multilayer-based soft X-ray polarimeter is given. The use of an APPLE II undulator is extremely important for providing a high-brilliance X-ray beam with the capability to switch between various photon beam polarization states. A high-precision soft X-ray polarimeter has been used to systematically investigate the polarization characteristics of the two helical APPLE II undulators installed on beamline I06 at Diamond Light Source. A simple data acquisition and processing procedure has been developed to determine the Stokes polarization parameters for light polarized at arbitrary linear angles emitted from a single undulator, and for circularly polarized light emitted from both undulators in conjunction with a single-period undulator phasing unit. The purity of linear polarization is found to deteriorate as the polarization angle moves away from the horizontal and vertical modes. Importantly, a negative correlation between the degree of circular polarization and the photon flux has been found when the phasing unit is used.

  10. Complexes of Cu(II), Ni(II), Co(II), oxovanadium(IV) and dioxouranium(VI) with N,N'-ethylenebis (2-hydroxy-4-methylpropiophenoneimine)

    International Nuclear Information System (INIS)

    Patel, M.M.; Patel, M.R.; Patel, M.N.; Patel, R.P.

    1982-01-01

    Complexes of Cu(II), Ni(II), Co(II), oxovanadium(IV) and dioxouranium(VI) with the schiff base, N,N'-ethylenebis(2-hydroxy-4-methylpropiophenoneimine)(4-MeOHPEN), have been synthesised and characterised on the basis of elemental analyses, conductivity, magnetic moment, electronic and infrared spectral data. Square-planar structures are suggested for Cu(II), Ni(II) and Co(II) complexes while a distorted square-pyramidal structure is suggested for the oxovanadium(IV) complex. (author)

  11. Elaboration of a Highly Porous RuII,II Analogue of HKUST-1.

    Science.gov (United States)

    Zhang, Wenhua; Freitag, Kerstin; Wannapaiboon, Suttipong; Schneider, Christian; Epp, Konstantin; Kieslich, Gregor; Fischer, Roland A

    2016-12-19

    When the dinuclear Ru II,II precursor [Ru 2 (OOCCH 3 ) 4 ] is employed under redox-inert conditions, a Ru II,II analogue of HKUST-1 was successfully prepared and characterized as a phase-pure microcrystalline powder. X-ray absorption near-edge spectroscopy confirms the oxidation state of the Ru centers of the paddle-wheel nodes in the framework. The porosity of 1371 m 2 /mmol of Ru II,II -HKUST-1 exceeds that of the parent compound HKUST1 (1049 m 2 / mmol).

  12. Dynamic adsorption of mixtures of Rhodamine B, Pb (II), Cu (II) and Zn(II) ions on composites chitosan-silica-polyethylene glycol membrane

    Science.gov (United States)

    Mahatmanti, F. W.; Rengga, W. D. P.; Kusumastuti, E.; Nuryono

    2018-04-01

    The adsorption of a solution mixture of Rhodamine B, Pb (II), Cu (II) and Zn(II) was studied using dynamic methods employing chitosan-silica-polyethylene glycol (Ch/Si/P) composite membrane as an adsorptive membrane. The composite Ch/Si/P membrane was prepared by mixing a chitosan-based membrane with silica isolated from rice husk ash (ASP) and polyethylene glycol (PEG) as a plasticizer. The resultant composite membrane was a stronger and more flexible membrane than the original chitosan-based membrane as indicated by the maximum percentage of elongation (20.5 %) and minimum Young’s Modulus (80.5 MPa). The composite membrane also showed increased mechanical and hydrophilic properties compared to the chitosan membranes. The membrane was used as adsorption membrane for Pb (II), Cu (II), Cd (II) ions and Rhodamine B dyes in a dynamic system where the permeation and selectivity were determined. The permeation of the components was observed to be in the following order: Rhodamine B > Cd (II) > Pb (II) > Cu (II) whereas the selectivity was shown to decrease the order of Cu (II) > Pb (II) > Cd (II) > Rhodamine B.

  13. Perception and acceptance of technological risk sources. Vol. 2

    International Nuclear Information System (INIS)

    Renn, O.

    1981-01-01

    Volume II presents a comparative investigation of risk perception and acceptance. It contains the evaluations of the two experiments in social psychology and the analysis of two intensive enquiries concerning risk perception with a view to 12 different risk sources. The data of the two enquiries were acquired from a total of 200 interview partners in two cities in North-Rhine Westphalia. (orig./HP) [de

  14. The Integration of Renewable Energy Sources into Electric Power Distribution Systems, Vol. II Utility Case Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Zaininger, H.W.

    1994-01-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: the local solar insolation and/or wind characteristics, renewable energy source penetration level, whether battery or other energy storage systems are applied, and local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kW-scale applications may be connected to three+phase secondaries, and larger hundred-kW and y-scale applications, such as MW-scale windfarms, or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. In any case, the installation of small, distributed renewable energy sources is expected to have a significant impact on local utility distribution primary and secondary system economics. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications. The

  15. Depositional environments and oil potential of Jurassic/Cretaceous source rocks within the Seychelles microcontinent

    Energy Technology Data Exchange (ETDEWEB)

    Plummer, P.S.; Joseph, P.R.; Samson, P.J. [Seychelles National Oil Co., Mahe (Seychelles)

    1998-12-31

    The Seychelles microcontinent became isolated between the Somali, Mascarene and Arabian basins of the Indian Ocean as a result of the Mesozoic fragmentation of Gondwana. Major rifting events occurred during the Triassic-Middle Jurassic and Late Cretaceous (Cenomanian-Santonian and Maastrichtian) during which shaly source rock facies accumulated in principally marginal marine/deltaic environments. Between these times, post-rift passive margin deposition within restricted to open marine environments produced shaly source rocks during late Middle Jurasic-Early Cretaceous, Campanian-Maastrichtian and Paleocene times. Recent geochemical analysis of cuttings from the Seagull Shoals-1 well has identified an oil-prone liptinitic (Type II) coaly shale within early Middle Jurassic abandoned deltaic deposits. This coaly source rock is regionally developed, having also been identified in the Majunja and Morondava basins of Madagascar. Oil-prone Type II organic matter has also been identified in the Owen Bank A-1 well within restricted marine shales of late Middle Jurassic age. These shales are part of a thick post-rift source rock sequence that extends into the Early Cretaceous and is in part correlative with the proven Late Jurassic Uarandab Shale of Somalia. Analysis of Campanian marine shales from Reith Bank-1 well identified significant dilution of total organic carbon content in composite, compared to picked, well cuttings samples. This finding supports a published inference that these post-rift shales have source rock potential. (author)

  16. Serum insulin-like growth factor II (IGF-II) in chronic heart failure

    International Nuclear Information System (INIS)

    Tong Lijun; Chen Donghai; Ji Naijun; Fan Bifu; Wang Chengyao; Mei Yibin; Li Fuyuan; Kao Yan

    2004-01-01

    Objective: To investigate the clinical significance of changes of serum insulin-like growth factor II (IGF-II) levels in patients with chronic heart failure. Methods: Serum IGF-II levels were measured with RIA in 132 cases of chronic heart failure and 45 controls. Results: Serum IGF-II levels were significantly higher in patients with chronic heart failure than those in the controls (t=0.033, P<0.001). IGF-II levels were highest in grade IV CHF patients (vs grade II t=3.963, P<0.01; vs grade III, t=3.578, P<0.01). In the twelve patients died in hospital, the serum IGF-II levels were significantly higher than those patients recovered (t=7.141, P<0.01). Conclusion: Serum IGF-II levels were increased in CHF patients and were highest in the most severe cases. (authors)

  17. Present and Past Impact of Glacially Sourced Dust on Iron Fertilization of the Southern Ocean

    Science.gov (United States)

    Shoenfelt, E. M.; Winckler, G.; Kaplan, M. R.; Sambrotto, R.; Bostick, B. C.

    2016-12-01

    An increase in iron-containing dust flux and a more efficient biological pump in the Southern Ocean have been associated with the CO2 drawdown and global cooling of the Last Glacial Maximum (LGM). While iron (Fe) mineralogy is known to affect Fe bioavailability through its impact on Fe solubility, there are limited studies investigating the importance of Fe mineralogy in dust fluxes to the Southern Ocean, and no previous studies investigating interactions between eukaryotic phytoplankton and particulate-phase Fe in natural dusts applicable to Southern Ocean environments. Since physically weathered bedrock becomes less soluble as it becomes weathered and oxidized, we hypothesized that glacially sourced dusts would contain more Fe(II)-rich primary minerals and would be more bioavailable than dusts from areas not impacted by glaciers. We used a series of natural dusts from Patagonia as the sole Fe source in incubation experiments with the model diatom Phaeodactylum tricornutum, and evaluated Fe bioavailability using culture growth rates, cell density, and variable fluorescence. Monod curves were also used to evaluate the efficiency of the different particulates as sources of nutrient Fe. Using these Monod curves fit to growth rates plotted against particulate Fe concentrations, we observed that 1) Fe(II)-rich primary silicates were significantly more effective as an Fe source to diatoms than Fe(III)-rich oxides, that 2) Fe(II) content itself was responsible for the difference in Fe bioavailability/efficiency of the Fe nutrient source, and that 3) surface interactions with the particulates were important. In an effort to explore the possibility that Fe mineralogy impacted Fe bioavailability in past oceans, we will present our hypotheses regarding productivity and Fe mineralogy/bioavailability through the last glacial cycle.

  18. [C II] 158 μm EMISSION AS A STAR FORMATION TRACER

    Energy Technology Data Exchange (ETDEWEB)

    Herrera-Camus, R.; Bolatto, A. D.; Wolfire, M. G. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Smith, J. D. [Department of Physics and Astronomy, University of Toledo, 2801 West Bancroft Street, Toledo, OH 43606 (United States); Croxall, K. V. [Department of Astronomy, The Ohio State University, 4051 McPherson Laboratory, 140 West 18th Avenue, Columbus, OH 43210 (United States); Kennicutt, R. C.; Boquien, M. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Calzetti, D. [Department of Astronomy, University of Massachusetts, Amherst, MA 01003 (United States); Helou, G. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Walter, F.; Meidt, S. E. [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Leroy, A. K. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Draine, B. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Brandl, B. R. [Leiden Observatory, Leiden University, P.O. Box 9513, 2300-RA Leiden (Netherlands); Armus, L. [Spitzer Science Center, California Institute of Technology, MC 314-6, Pasadena, CA 91125 (United States); Sandstrom, K. M. [Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Dale, D. A. [Department of Physics and Astronomy, University of Wyoming, Laramie, WY 82071 (United States); Aniano, G. [Institut d' Astrophysique Spatiale, CNRS (UMR8617) Université Paris-Sud 11, Batiment 121, Orsay (France); Hunt, L. K. [INAF-Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125 Firenze (Italy); Galametz, M. [European Southern Observatory, Karl Schwarzschild Strasse 2, D-85748 Garching (Germany); and others

    2015-02-10

    The [C II] 157.74 μm transition is the dominant coolant of the neutral interstellar gas, and has great potential as a star formation rate (SFR) tracer. Using the Herschel KINGFISH sample of 46 nearby galaxies, we investigate the relation of [C II] surface brightness and luminosity with SFR. We conclude that [C II] can be used for measurements of SFR on both global and kiloparsec scales in normal star-forming galaxies in the absence of strong active galactic nuclei (AGNs). The uncertainty of the Σ{sub [C} {sub II]} – Σ{sub SFR} calibration is ±0.21 dex. The main source of scatter in the correlation is associated with regions that exhibit warm IR colors, and we provide an adjustment based on IR color that reduces the scatter. We show that the color-adjusted Σ{sub [C} {sub II]} – Σ{sub SFR} correlation is valid over almost five orders of magnitude in Σ{sub SFR}, holding for both normal star-forming galaxies and non-AGN luminous infrared galaxies. Using [C II] luminosity instead of surface brightness to estimate SFR suffers from worse systematics, frequently underpredicting SFR in luminous infrared galaxies even after IR color adjustment (although this depends on the SFR measure employed). We suspect that surface brightness relations are better behaved than the luminosity relations because the former are more closely related to the local far-UV field strength, most likely the main parameter controlling the efficiency of the conversion of far-UV radiation into gas heating. A simple model based on Starburst99 population-synthesis code to connect SFR to [C II] finds that heating efficiencies are 1%-3% in normal galaxies.

  19. Recent validation tests of the Edelweiss II detector holders

    International Nuclear Information System (INIS)

    Schwamm, F.; Chapellier, M.; Herve, S.; Karolak, M.; Navick, X.-F.

    2006-01-01

    A very good understanding of noise sources is highly important for the sensitivity of a dark matter search experiment. One of these noise contributions in the Edelweiss experiment could be the microphonics and temperature variations caused by vibrations of the cryostat. Recent studies complement an earlier work in describing the effect of the Edelweiss II detector holders on the amplitude of the vibrations seen by the detector. The results of these studies will be presented in this article

  20. Source term model evaluations for the low-level waste facility performance assessment

    Energy Technology Data Exchange (ETDEWEB)

    Yim, M.S.; Su, S.I. [North Carolina State Univ., Raleigh, NC (United States)

    1995-12-31

    The estimation of release of radionuclides from various waste forms to the bottom boundary of the waste disposal facility (source term) is one of the most important aspects of LLW facility performance assessment. In this work, several currently used source term models are comparatively evaluated for the release of carbon-14 based on a test case problem. The models compared include PRESTO-EPA-CPG, IMPACTS, DUST and NEFTRAN-II. Major differences in assumptions and approaches between the models are described and key parameters are identified through sensitivity analysis. The source term results from different models are compared and other concerns or suggestions are discussed.

  1. The European Dioxin Emission Inventory. Stage II. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Quass, U.; Fermann, M.; Broeker, G.

    2001-07-01

    For Stage II of the European Dioxin Project the following objectives were set: - Amendment of existing emission data collected for most relevant emission sources in order to reduce uncertainties of emission estimates. Collecting first emission data from countries not yet performing dioxin emission measurement programs. Extending the inventory of dioxin emissions to ambient air produced in Stage I by a complementary study on emissions to land and water. Extending the regional scope of data collection to countries in Central Europe. The report of Stage II of the European Dioxin Project is presented in 3 Volumes. Volume 1 contains an overview on the background and approach of different activities carried out and on the results obtained. These results are put into a broader view regarding the dioxin reduction measures in Europe leading to conclusions and recommendation for future work. Volume 2 of the report contains a detailed presentation of the sub-projects carried out. The chapters of Volume 2 are structured in a similar manner and start with a short summary in order to allow for a fast cross-reading. In the case of the desk-top studies an overview of the main results or statements is given. Regarding emission measurements details on the experimental set-up and the facilities being investigated are presented. Volume 3 contains a re-evaluation of the dioxin emission inventory presented for the most relevant sources types in the Stage I report. New data gathered from the projects of Stage II as well as from independent activities in the European countries are considered for a revision of the 1995 emission estimates. Additionally, based on current trends and activities the PCDD/F emissions for the years 2000 and 2005 are estimated. Finally, an attempt is made to evaluate the PCDD/F emission reduction rates which might be possible to achieve by the year 2005 compared to 1985. (orig.)

  2. First Detections of the [N II] 122 micron Line at High Redshift: Demonstrating the Utility of the Line for Studying Galaxies in the Early Universe

    Science.gov (United States)

    Ferkinhoff, Carl; Brisbin, Drew; Nikola, Thomas; Parshley, Stephen C.; Stacey, Gordon J.; Phillips, Thomas G.; Falgarone, Edith; Benford, Dominic J.; Staguhn, Johannes G.; Tucker, Carol E.

    2011-01-01

    We report the first detections of the [N II] 122 micron line from a high-redshift galaxy. The line was strongly (>6(sigma)) detected from SMMJ02399-0136, and H1413 + 117 (the Cloverleaf QSO) using the Redshift (zeta) and Early Universe Spectrometer on the Caltech Submillimeter Observatory. The lines from both sources are quite bright with line to far-infrared (FIR) continuum luminosity ratios that are approx.7.0 x 10(exp -4) (Cloverleaf) and 2.1 x 10(exo -3) (SMMJ02399). With ratios 2-10 times larger than the average value for nearby galaxies, neither source exhibits the line to continuum deficits seen in nearby sources. The line strengths also indicate large ionized gas fractions, approx.8%-17% of the molecUlar gas mass. The [O III]/[N II] line ratio is very sensitive to the effective temperature of ionizing stars and the ionization parameter for emission arising in the narrow-line region (NLR) of an active galactic nucleus (AGN). Using Our previous detection of the [O III] 88 micron line, the [O III]/[N II]line ratio for SMMJ02399-0136 indicates that the dominant source of the line emission is either stellar H II regions ionized by O9.5 stars, or the NLR of the AGN with ionization parameter log(U) = -3.3 to -4.0. A composite system, where 30%-50% of the FIR lines arise in the NLR also matches the data. The Cloverleaf is best modeled by a superposition of approx.200 M82-like starbursts accounting for all of the FIR emission and 43% of the [N II]line. The remainder may come from the NLR. This war!< demonstrates the utility of the [N II] and [O III] lines in constraining properties of the ionized medium.

  3. Operating limits for subassembly deformation in EBR-II

    International Nuclear Information System (INIS)

    Bottcher, J.H.

    1977-01-01

    The deformation of a subassembly in response to the core environment is frequently the life limiting factor for that component in an LMFBR. Deformation can occur as diametral and axial growth or bowing of the subassembly. Such deformation has caused several handling problems in both the core and the storage basket of EBR-II and may also have contributed to reactivity anomalies during reactor operation. These problems generally affect plant availability but the reactivity anomalies could lead to a potential safety hazard. Because of these effects the deformation mechanisms must be understood and modeled. Diametral and axial growth of subassembly ducts in EBR-II is due to swelling and creep and is a function of temperature, neutron fluence and stress. The source of stress in a duct is the hydraulic pressure difference across the wall. By coupling the calculated subassembly growth rate to the available clearance in the core or storage basket a limiting neutron fluence, or exposure, can be established

  4. The spectrum of singly ionized yttrium, Y II

    International Nuclear Information System (INIS)

    Nilsson, A.E.; Johansson, S.; Kurucz, R.L.

    1991-01-01

    Hollow-cathode spectra of yttrium have been registered in the wavelength region 1000-48800 A. Resonant charge transfer reactions in the light source favour the excitation of Y II, where 174 new levels have been established by means of 1284 newly classified lines. Altogether we report 1521 lines between 235 levels in Y II. The ground complex (4d+5s) 2 is now completely known and a number of Rydberg series have been extended. The new levels belong to the 4dnl (nl=7s, 8s, 9s, 6p, 7p, 4d, 5d, 6d, 7d, 8d, 4f, 5f, 6f, 7f, 5g) and 5snl (nl=7s, 8s, 6p, 6d, 4f, 5f) configurations. Eigenvector compositions, based on paramagnetic calculations including configuration interaction, are given for all levels. The ionization limit has been determined to 98590 ± 5 cm -1 . (orig.)

  5. Coronal mass ejections, type II radio bursts, and solar energetic particle events in the SOHO era

    Directory of Open Access Journals (Sweden)

    N. Gopalswamy

    2008-10-01

    Full Text Available Using the extensive and uniform data on coronal mass ejections (CMEs, solar energetic particle (SEP events, and type II radio bursts during the SOHO era, we discuss how the CME properties such as speed, width and solar-source longitude decide whether CMEs are associated with type II radio bursts and SEP events. We discuss why some radio-quiet CMEs are associated with small SEP events while some radio-loud CMEs are not associated with SEP events. We conclude that either some fast and wide CMEs do not drive shocks or they drive weak shocks that do not produce significant levels of particle acceleration. We also infer that the Alfvén speed in the corona and near-Sun interplanetary medium ranges from <200 km/s to ~1600 km/s. Radio-quiet fast and wide CMEs are also poor SEP producers and the association rate of type II bursts and SEP events steadily increases with CME speed and width (i.e. energy. If we consider western hemispheric CMEs, the SEP association rate increases linearly from ~30% for 800 km/s CMEs to 100% for ≥1800 km/s. Essentially all type II bursts in the decametre-hectometric (DH wavelength range are associated with SEP events once the source location on the Sun is taken into account. This is a significant result for space weather applications, because if a CME originating from the western hemisphere is accompanied by a DH type II burst, there is a high probability that it will produce an SEP event.

  6. A Tool for Predicting Regulatory Approval After Phase II Testing of New Oncology Compounds.

    Science.gov (United States)

    DiMasi, J A; Hermann, J C; Twyman, K; Kondru, R K; Stergiopoulos, S; Getz, K A; Rackoff, W

    2015-11-01

    We developed an algorithm (ANDI) for predicting regulatory marketing approval for new cancer drugs after phase II testing has been conducted, with the objective of providing a tool to improve drug portfolio decision-making. We examined 98 oncology drugs from the top 50 pharmaceutical companies (2006 sales) that first entered clinical development from 1999 to 2007, had been taken to at least phase II development, and had a known final outcome (research abandonment or regulatory marketing approval). Data on safety, efficacy, operational, market, and company characteristics were obtained from public sources. Logistic regression and machine-learning methods were used to provide an unbiased approach to assess overall predictability and to identify the most important individual predictors. We found that a simple four-factor model (activity, number of patients in the pivotal phase II trial, phase II duration, and a prevalence-related measure) had high sensitivity and specificity for predicting regulatory marketing approval. © 2015 American Society for Clinical Pharmacology and Therapeutics.

  7. Tuning the DARHT Axis-II linear induction accelerator focusing

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A. [Los Alamos National Laboratory

    2012-04-24

    Flash radiography of large hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories, and the Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos produces flash radiographs of large hydrodynamic experiments. Two linear induction accelerators (LIAs) make the bremsstrahlung radiographic source spots for orthogonal views of each test. The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. The 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by kicking them out of a longer pulse that has a 1.6-{mu}s flattop. The Axis-II injector, LIA, kicker, and downstream transport (DST) to the bremsstrahlung converter are described. Adjusting the magnetic focusing and steering elements to optimize the electron-beam transport through an LIA is often called 'tuning.' As in all high-current LIAs, the focusing field is designed to be as close to that of the ideal continuous solenoid as physically possible. In ideal continuous solenoidal transport a smoothly varying beam size can easily be found for which radial forces balance, and the beam is said to be 'matched' to the focusing field. A 'mismatched' beam exhibits unwanted oscillations in size, which are a source of free energy that contributes to emittance growth. This is undesirable, because in the absence of beam-target effects, the radiographic spot size is proportional to the emittance. Tuning the Axis-II LIA is done in two steps. First, the solenoidal focusing elements are set to values designed to provide a matched beam with little or no envelope oscillations, and little or no beam-breakup (BBU) instability growth. Then, steering elements are adjusted to minimize the motion of the centroid of a well-centered beam at the LIA exit. This article only describes the design of the tune for the focusing solenoids. The DARHT Axis-II LIA was required to be re-tuned after installing an

  8. Exclusive radiation therapy of endometrial carcinoma using HDR Co-60 and Cf-252 sources

    International Nuclear Information System (INIS)

    Inciura, A.; Janulionis, E.; Atkocius, V.

    2000-01-01

    Although the main treatment of endometrial cancer is surgery, the gross spread of carcinoma in pelvis, elderly age of the patients and serious therapeutical diseases do not allow to operate 20% of the patients. For these patients only radical treatment decision is the combined radiation therapy. However, using various modalities of combined radiotherapy, the treatment results are not satisfying: only 52% of patients survive 5 years. There was implemented a new method of combined radiotherapy, using a three-channel applicator with two-positional locating of HDR Co-60 radioactive sources (group I). A new method of brachytherapy for endometrial carcinoma using a HDR Cf 252 sources (group II) was implemented too. For group I the medium total dose of the point A was 77.6 Gy, point I - 69.6 Gy. point 2 - 84.2 Gy, point B - 52.6 Gy, For group II the medium total dose the points A, 3 and 4 was 50 iGy. For group I 1 year overaII survival rate was 85%, 3 year - 73%. The 3 year survival rate for stage I was 79%, for stage II - 89%, for stage III - 33%. 3 year survival for highly virulent tumours - 56% and for low virulent (adenocarcinoma) - 82% was statistically different. The loss of tumour differentiation correlated with the worse prognosis: 3 year survival for G1 and G2 tumours was 92%, for G3 - 45%. Low hemoglobin level was also associated with low survival rate: 2 year survival for Hb≥120g/l was 85% and Hb<120g/l - 23%. 1 year survival rate was 87%, 3 year - 66%, 5 year - 58% for group II, treated with Cf-252. Radiation complications occurred for 13.8% of the patients for group I and 6.2% for group II. Good survival rates and a small number of complications sufficiently proofed treatment method. (author)

  9. Ni(II, Pd(II and Pt(II complexes with ligand containing thiosemicarbazone and semicarbazone moiety: synthesis, characterization and biological investigation

    Directory of Open Access Journals (Sweden)

    SULEKH CHANDRA

    2008-07-01

    Full Text Available The synthesis of nickel(II, palladium(II and platinum(II complexes with thiosemicarbazone and semicarbazone of p-tolualdehyde are reported. All the new compounds were characterized by elemental analysis, molar conductance measurements, magnetic susceptibility measurements, mass, 1H-NMR, IR and electronic spectral studies. Based on the molar conductance measurements in DMSO, the complexes may be formulated as [Ni(L2Cl2] and [M(L2]Cl2 (where M = Pd(II and Pt(II due to their non-electrolytic and 1:2 electrolytic nature, respectively. The spectral data are consistent with an octahedral geometry around Ni(II and a square planar geometry for Pd(II and Pt(II, in which the ligands act as bidentate chelating agents, coordinated through the nitrogen and sulphur/oxygen atoms. The ligands and their metal complexes were screened in vitro against fungal species Alternaria alternata, Aspergillus niger and Fusarium odum, using the food poison technique.

  10. Anti-inflammatory drugs interacting with Zn(II), Cd(II) and Pt(II) metal ions.

    Science.gov (United States)

    Dendrinou-Samara, C; Tsotsou, G; Ekateriniadou, L V; Kortsaris, A H; Raptopoulou, C P; Terzis, A; Kyriakidis, D A; Kessissoglou, D P

    1998-09-01

    Complexes of Zn(II), Cd(II) and Pt(II) metal ions with the anti-inflammatory drugs, 1-methyl-5-(p-toluoyl)-1H-pyrrole-2-acetic acid (Tolmetin), alpha-methyl-4-(2-methylpropyl)benzeneacetic acid (Ibuprofen), 6-methoxy-alpha-methylnaphthalene-2-acetic acid (Naproxen) and 1-(4-chlorobenzoyl)-5-methoxy-2-methyl-1H-indole-3-acetic acid (indomethacin) have been synthesized and characterized. In the structurally characterized Cd(naproxen)2 complex the anti-inflammatory drugs acts as bidentate chelate ligand coordinatively bound to metal ions through the deprotonated carboxylate group. Crystal data for 1: [C32H26O8Cd], orthorhombic, space group P22(1)2(1), a = 5.693(2) (A), b = 8.760(3) (A), c = 30.74(1) (A), V = 1533(1) A3, Z = 2. Antibacterial and growth inhibitory activity is higher than that of the parent ligands or the platinum(II) diamine compounds.

  11. Conditions Database for the Belle II Experiment

    Science.gov (United States)

    Wood, L.; Elsethagen, T.; Schram, M.; Stephan, E.

    2017-10-01

    The Belle II experiment at KEK is preparing for first collisions in 2017. Processing the large amounts of data that will be produced will require conditions data to be readily available to systems worldwide in a fast and efficient manner that is straightforward for both the user and maintainer. The Belle II conditions database was designed with a straightforward goal: make it as easily maintainable as possible. To this end, HEP-specific software tools were avoided as much as possible and industry standard tools used instead. HTTP REST services were selected as the application interface, which provide a high-level interface to users through the use of standard libraries such as curl. The application interface itself is written in Java and runs in an embedded Payara-Micro Java EE application server. Scalability at the application interface is provided by use of Hazelcast, an open source In-Memory Data Grid (IMDG) providing distributed in-memory computing and supporting the creation and clustering of new application interface instances as demand increases. The IMDG provides fast and efficient access to conditions data via in-memory caching.

  12. Glucose 6P binds and activates HlyIIR to repress Bacillus cereus haemolysin hlyII gene expression.

    Directory of Open Access Journals (Sweden)

    Elisabeth Guillemet

    Full Text Available Bacillus cereus is a Gram-positive spore-forming bacterium causing food poisoning and serious opportunistic infections. These infections are characterized by bacterial accumulation despite the recruitment of phagocytic cells. We have previously shown that B. cereus Haemolysin II (HlyII induces macrophage cell death by apoptosis. In this work, we investigated the regulation of the hlyII gene. We show that HlyIIR, the negative regulator of hlyII expression in B. cereus, is especially active during the early bacterial growth phase. We demonstrate that glucose 6P directly binds to HlyIIR and enhances its activity at a post-transcriptional level. Glucose 6P activates HlyIIR, increasing its capacity to bind to its DNA-box located upstream of the hlyII gene, inhibiting its expression. Thus, hlyII expression is modulated by the availability of glucose. As HlyII induces haemocyte and macrophage death, two cell types that play a role in the sequestration of nutrients upon infection, HlyII may induce host cell death to allow the bacteria to gain access to carbon sources that are essential components for bacterial growth.

  13. Social Set Visualizer (SoSeVi) II

    DEFF Research Database (Denmark)

    Flesch, Benjamin; Vatrapu, Ravi

    2016-01-01

    This paper reports the second iteration of the Social Set Visualizer (SoSeVi), a set theoretical visual analytics dashboard of big social data. In order to further demonstrate its usefulness in large-scale visual analytics tasks of individual and collective behavior of actors in social networks......, the current iteration of the Social Set Visualizer (SoSeVi) in version II builds on recent advancements in visualizing set intersections. The development of the SoSeVi dashboard involved cutting-edge open source visual analytics libraries (D3.js) and creation of new visualizations such as of actor mobility...

  14. Influence of meat source, pH and production time on zinc protoporphyrin IX formation as natural colouring agent in nitrite-free dry fermented sausages.

    Science.gov (United States)

    De Maere, Hannelore; Chollet, Sylvie; De Brabanter, Jos; Michiels, Chris; Paelinck, Hubert; Fraeye, Ilse

    2018-01-01

    Nitrite is commonly used in meat products due to its plural technological advantages. However, it is controversial because of its detrimental side effects on health. Within the context of nitrite reduction, zinc protoporphyrin IX (Zn(II)PPIX) formation in meat products as natural red colouring agent has been suggested. This investigation presents the evaluation of naturally occurring pigments, namely Zn(II)PPIX, protoporphyrin IX (PPIX) and heme in nitrite-free dry fermented sausages in function of time, meat source (pork, horsemeat and a combination of both meat sources) and pH condition. In function of time, Zn(II)PPIX and PPIX were formed and heme content decreased. Higher pH conditions promoted Zn(II)PPIX and PPIX formation, whereas the influence of pH on heme was less clear. The use of horsemeat also promoted Zn(II)PPIX formation. Moreover, even similar amounts were formed when it was combined with pork. Product redness, however, could not be related to Zn(II)PPIX formation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Synthesis, spectroscopic and antimicrobial properties of Co(II), Ni (II ...

    African Journals Online (AJOL)

    The objective of this study is to investigate the antimicrobial activity of novel Schiff base metal complexes. The resistance of micro-organisms to classical antimicrobial compounds poses a challenge to effective management and treatment of some diseases. In line with this, copper (II), nickel (II) and cobalt (II) complexes of ...

  16. Ion source and injection line for high intensity medical cyclotron

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  17. Development of a user-friendly interface version of the Salmonella source-attribution model

    DEFF Research Database (Denmark)

    Hald, Tine; Lund, Jan

    of travel and outbreak-related cases, also per country and subtype, ii) food-animal prevalence data per country and subtype, including the number of units tested and the number of positive units, and iii) data on the production and trade of the different food-animal sources in the EU Member States. The EFSA...... cases by subtype including data on the number of travel, domestic, unknown travel history and outbreak-related cases, also per subtype, ii) food-animal prevalence data per subtype, including the number of units tested and the number of positive units, and iii) data on the amount of the included animal...... for example in future mandates dealing with similar questions. The objective of the work described in this report was, therefore, to develop a flexible and user-friendly interface for attributing human cases of food-borne pathogens to the responsible food-animal reservoirs and/or food sources. The interface...

  18. The History and Evolution of Young and Distant Radio Sources

    Science.gov (United States)

    Collier, Jordan

    convex spectrum is generally thought to be caused by Synchrotron Self Absorption (SSA), an internal process in which the same population of electrons is responsible for the synchrotron emission and self-absorption. However, recent studies have shown that the convex spectrum may be caused by Free-Free Absorption (FFA), an external process in which an inhomogeneous screen absorbs the synchrotron emission. The majority of GPS and CSS samples consist of Jy-level and therefore, high-luminosity sources. VLBI images show that GPS and CSS sources typically have double-lobed, edge-brightened morphologies on mas scales, appearing as scaled down versions of Fanaroff-Riley Class II (FR II) galaxies. Recently, two low-luminosity GPS sources were found to have jet-brightened morphologies, which appeared as scaled down versions of Fanaroff-Riley Class I (FR I) galaxies. From this, it was proposed that there exists a morphology-luminosity break analogous to the FR I/II break and that low-luminosity GPS and CSS sources are the compact counterparts of FR I galaxies. However, this hypothesis remains unconfirmed, since very few samples of low-luminosity GPS and CSS sources exist. We conclude that, despite being historically favoured, single inhomogeneous SSA is not the dominant form of absorption amongst a large fraction of GPS and CSS sources. We find that FFA provides a good model for the majority of the spectra with observable turnovers, suggesting an inhomogeneous and clumpy ambient medium. Furthermore, we conclude that the majority of our GPS and CSS sources are young and evolving and may undergo recurrent activity over small time scales. We conclude that a very small fraction of GPS and CSS sources consists of frustrated, dying or restarted radio galaxies. (Abstract shortened by ProQuest.).

  19. Extraction magnetically insulated diode studies on Gamble II

    International Nuclear Information System (INIS)

    Neri, J.M.; Boller, J.R.; Ottinger, P.F.; Stephanakis, S.J.; Greenly, J.

    1993-01-01

    An extraction Magnetically Insulated Diode (MID) with anode and cathode magnetic field coils has been tested on the NRL Gamble II accelerator. The purpose of the experiments is to develop an annular, intense ion beam source for testing ion beam transport physics related to light ion inertial confinement fusion. Initial experiments have been performed with surface flashover ion sources. The experimental challenge has been to obtain a tuning of the 4 magnetic field coils that results in a minimum turn-on time of the ion source and acceptable coupling to the accelerator. Results from several different geometries of magnetic field will be presented. The principal diode diagnostics are the total diode current, net ion current, and corrected diode voltage. Calculations of the magnetic field strength and geometry are performed with the ATHETA code. An active anode ion source is also under development. The initial portion of the accelerator pulse is diverted with a plasma opening switch (POS) and passed through a thin foil that will become the ion source. The foil is swiftly heated by the current pulse and gas is desorbed or diffused from the foil into the anode-cathode gap. The gas is then broken down by the current pulse, forming a dense plasma source on the anode surface. Two different foils are being used. A thin aluminum foil will work with desorbed gases, and provide a beam that is predominately protons. A hydrogen loaded titanium foil, with a paladium overcoating, will use diffused hydrogen, and produce a high purity proton beam. The net result of the POS and active anode plasma source should be much faster ion turn-on time, and better coupling of the ion source to the accelerator. Preliminary results with the active anode sources will be presented

  20. A Parallel Controls Software Approach for PEP II: AIDA and Matlab Middle Layer

    International Nuclear Information System (INIS)

    Wittmer, W.; Colocho, W.; White, G.

    2007-01-01

    The controls software in use at PEP II (Stanford Control Program - SCP) had originally been developed in the eighties. It is very successful in routine operation but due to its internal structure it is difficult and time consuming to extend its functionality. This is problematic during machine development and when solving operational issues. Routinely, data has to be exported from the system, analyzed offline, and calculated settings have to be reimported. Since this is a manual process, it is time consuming and error-prone. Setting up automated processes, as is done for MIA (Model Independent Analysis), is also time consuming and specific to each application. Recently, there has been a trend at light sources to use MATLAB as the platform to control accelerators using a 'MATLAB Middle Layer' (MML), and so called channel access (CA) programs to communicate with the low level control system (LLCS). This has proven very successful, especially during machine development time and trouble shooting. A special CA code, named AIDA (Accelerator Independent Data Access), was developed to handle the communication between MATLAB, modern software frameworks, and the SCP. The MML had to be adapted for implementation at PEP II. Colliders differ significantly in their designs compared to light sources, which poses a challenge. PEP II is the first collider at which this implementation is being done. We will report on this effort, which is still ongoing

  1. [Evaluation of serum PIVKA-II by Lumipulse PrestoII assay].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Kani, Satomi; Goto, Takaaki; Takasaka, Yoshimitsu; Matsuura, Kentaro; Sugauchi, Fuminaka; Moriyama, Kazushige; Murakami, Hiroshi; Kitajima, Sachiko; Mizokami, Masashi

    2009-03-01

    Measurements of serum concentrations of Des-gamma-carboxy Prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, in Lumipulsef assay, it was reported that antibodies against alkaline phosphatase (ALP) derived from anti bleeding sheets led false high values of PIVKA-II in the patients with HCC resection. To improve the previous issue, newly developed Lumipulse PrestoII assay was examined. (1) The assay was reliable and positively correlated with the previous assays (Lumipulse f and Picolumi, R = 0.997 and 0.994 (n=115), respectively). (2) Eleven cases, which had false high values of PIVKA-II by the Lumipulsef assay, were examined by the PrestoII assay with excess of inactive ALP. The false high values of 10 cases were improved, but only one was still high. False reactivity of this case was stronger than other cases, more effective adsorption was required. (3) Comparing the absorbent activity of inactive ALP among 6 different kinds, we found inactive ALP with much higher adsorbent activity. When this inactive ALP was applied to assay, false high values of PIVKA-II were improved in all 11 cases. In conclusion, the PrestoII assay, which applies the inactive ALP with high activity, is reliable and useful for clinical screening.

  2. Elemental Composition of Mars Return Samples Using X-Ray Fluorescence Imaging at the National Synchrotron Light Source II

    Science.gov (United States)

    Thieme, J.; Hurowitz, J. A.; Schoonen, M. A.; Fogelqvist, E.; Gregerson, J.; Farley, K. A.; Sherman, S.; Hill, J.

    2018-04-01

    NSLS-II at BNL provides a unique and critical capability to perform assessments of the elemental composition and the chemical state of Mars returned samples using synchrotron radiation X-ray fluorescence imaging and X-ray absorption spectroscopy.

  3. (II) COMPLEX COMPOUND

    African Journals Online (AJOL)

    user

    electrochemical sensors, as well as in various chromatographic ... were carried out using Jenway pH meter Model 3320 and a conductivity ... Figure 1: the proposed molecular structure of the copper (II) Schiff base complex. M = Cu (II) or Mn (II).

  4. On-demand generation of background-free single photons from a solid-state source

    Science.gov (United States)

    Schweickert, Lucas; Jöns, Klaus D.; Zeuner, Katharina D.; Covre da Silva, Saimon Filipe; Huang, Huiying; Lettner, Thomas; Reindl, Marcus; Zichi, Julien; Trotta, Rinaldo; Rastelli, Armando; Zwiller, Val

    2018-02-01

    True on-demand high-repetition-rate single-photon sources are highly sought after for quantum information processing applications. However, any coherently driven two-level quantum system suffers from a finite re-excitation probability under pulsed excitation, causing undesirable multi-photon emission. Here, we present a solid-state source of on-demand single photons yielding a raw second-order coherence of g(2 )(0 )=(7.5 ±1.6 )×10-5 without any background subtraction or data processing. To this date, this is the lowest value of g(2 )(0 ) reported for any single-photon source even compared to the previously reported best background subtracted values. We achieve this result on GaAs/AlGaAs quantum dots embedded in a low-Q planar cavity by employing (i) a two-photon excitation process and (ii) a filtering and detection setup featuring two superconducting single-photon detectors with ultralow dark-count rates of (0.0056 ±0.0007 ) s-1 and (0.017 ±0.001 ) s-1, respectively. Re-excitation processes are dramatically suppressed by (i), while (ii) removes false coincidences resulting in a negligibly low noise floor.

  5. IGF-II receptors and IGF-II-stimulated glucose transport in human fat cells

    International Nuclear Information System (INIS)

    Sinha, M.K.; Buchanan, C.; Raineri-Maldonado, C.; Khazanie, P.; Atkinson, S.; DiMarchi, R.; Caro, J.F.

    1990-01-01

    Insulin-like growth factor II (IGF-II) receptors have been described in rat but not in human adipocytes. In both species, IGF-II has been reported to stimulate glucose transport by interacting with the insulin receptor. In this study, we have unequivocally demonstrated the presence of IGF-II receptors in human adipocytes. 125I-labeled IGF-II specifically binds to intact adipocytes, membranes, and lectin-purified detergent solubilized extracts. Through the use of 0.5 mM disuccinimidyl suberate, 125I-IGF-II is cross-linked to a 260-kDa protein that is identified as the IGF-II receptor by displacement experiments with unlabeled IGF-II, IGF-I, and insulin and either by immunoprecipitation or by Western blot analysis with mannose 6-phosphate receptor antibodies. The concentrations of IGF-II required for half-maximal and maximal stimulation of glucose transport in human adipocytes are 35 and 100 times more than that of insulin. The possibility of IGF-II stimulating glucose transport by interacting predominantly with the insulin receptor is suggested by the following: (1) the concentration of IGF-II that inhibits half of insulin binding is only 20 times more than that of insulin; (2) the lack of an additive effect of IGF-II and insulin for maximal stimulation of glucose transport; (3) the ability of monoclonal insulin receptor antibodies to decrease glucose transport stimulated by submaximal concentrations of both IGF-II and insulin; and (4) the ability of IGF-II to stimulate insulin receptor autophosphorylation albeit at a reduced potency when compared with insulin

  6. Emodin (1,3,8-trihydroxy-6-methylanthraquinone): a spectrophotometric reagent for the determination of beryllium(II), magnesium(II) and calcium(II)

    International Nuclear Information System (INIS)

    Pal, T.; Jana, N.R.

    1993-01-01

    The individual determination of Be II , Mg II or Ca II by conventional spectrophotometry and simultaneous determination of Mg II and Ca II in mixtures by first-derivative spectrophotometry are possible at trace levels, using emodin (1,3,8-trihydroxy-6-methylanthraquinone) as spectrophotometric reagent. Interference from other metal species, application of these methods to rock samples and statistical analysis of the results are discussed. (author)

  7. RF Feedback Analysis for 4 cavities per klystron in PEP-II

    International Nuclear Information System (INIS)

    Corredoura, P.; Tighe, R.

    1994-06-01

    Lattice changes in the PEP-II high energy ring have made the concept of driving four cavities with a single klystron an attractive option. This paper examines the topology from a RF feedback point of view. Sources of error are identified and their magnitudes are estimated. The effect on the performance of the longitudinal impedance reducing feedback loops is calculated using control theory and Mathematica

  8. Synthesis and studies on Cu(II), Co(II), Ni(II) complexes of Knoevenagel β-diketone ligands

    Science.gov (United States)

    Sumathi, S.; Tharmaraj, P.; Sheela, C. D.; Anitha, C.

    2012-11-01

    Transition metal complexes of various acetylacetone based ligands of the type ML [where M = Cu(II), Ni(II), Co(II); L = 3-(aryl)-pentane-2,4-dione] have been synthesized. The structural features have been derived from their elemental analysis, magnetic susceptibility, molar conductance, IR, UV-Vis, 1H NMR, Mass and ESR spectral studies. Conductivity measurements reveal that all the complexes are non-electrolytic in nature. Spectroscopic and other analytical data of the complexes suggest octahedral geometry for other metal(II) complexes. The redox behavior of the copper(II) complexes have been studied by cyclic voltammetry. The free ligands and their metal complexes have been screened for their in vitro biological activities against the bacteria Pseudomonas aeruginosa, Escherichia coli and Staphylococcus aureus as well as the fungus Candida albicans by well diffusion method. The zone of inhibition value indicates that the most of the metal(II) complexes are found to possess increased activities compared to those of the free ligands. All synthesized compounds may serve as potential photoactive materials as indicated from their characteristic fluorescence properties. The second harmonic generation (SHG) efficiency of the ligands (L1-L3) was found to be considerable effect than that of urea and KDP (potassium dihydrogen phosphate).

  9. Simulations Of Transverse Stacking In The NSLS-II Booster

    International Nuclear Information System (INIS)

    Fliller, R. III; Shaftan, T.

    2011-01-01

    The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The linac needs to deliver 15 nC in 80 - 150 bunches to the booster every minute to achieve current stability goals in the storage ring. This is a very stringent requirement that has not been demonstrated at an operating light source. We have developed a scheme to transversely stack two bunch trains in the NSLS-II booster in order to alleviate the charge requirements on the linac. This scheme has been outlined previously. In this paper we show particle tracking simulations of the tracking scheme. We show simulations of the booster ramp with a stacked beam for a variety of lattice errors and injected beam parameters. In all cases the performance of the proposed stacking method is sufficient to reduce the required charge from the linac. For this reason the injection system of the NSLS-II booster is being designed to include this feature. The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The injectors must provide 7.5nC in bunch trains 80-150 bunches long every minute for top off operation of the storage ring. Top off then requires that the linac deliver 15nC of charge once losses in the injector chain are taken into consideration. This is a very stringent requirement that has not been demonstrated at an operating light source. For this reason we have developed a method to transversely stack two bunch trains in the booster while maintaining the charge transport efficiency. This stacking scheme has been discussed previously. In this paper we show the simulations of the booster ramp with a single bunch train in the booster. Then we give a brief overview of the stacking scheme. Following, we show the results of stacking two bunch trains in the booster with varying beam emittances and train separations. The behavior of the beam through the ramp is examined showing that it is possible to stack two bunch trains in the booster.

  10. NBS SURF 11: A small versatile synchrotron light source

    International Nuclear Information System (INIS)

    Rakowsky, G.

    1981-01-01

    Synchrotron radiation sources do not have to be large multi-megadollar installations. SURF II is based on a compact electron storage ring with a radius of only 0.84 m, an operating energy of 250 MeV, and useful light output down to 5 nm. Small beam size, high brightness and wide-angle light ports give SURF II unique capabilities. Presently five beamlines are instrumented and operational, supporting experiments in atomic and molecular physics, surface science and materials studies, as well as providing optical calibration services. Nearing completion is a large facility for calibrating optical instruments, especially those intended for space flight. The capability of determining the absolute light flux emitted by SURF II has recently been improved and is now operational. The technique employs ultralinear silicon photodiodes to detect and count individual electrons in the stored beam. Other user conveniences include close access to the machine, flexible scheduling and close interaction with the operations staff. The machine's simplicity contributes to reliability and a high ratio of beamtime to downtime

  11. Bis(tripyrazol-1-ylmethanenickel(II tetracyanidonickelate(II dihydrate

    Directory of Open Access Journals (Sweden)

    Sean Parkin

    2009-12-01

    Full Text Available The title complex, [Ni(C10H10N62][Ni(CN4]·2H2O, contains an octahedral nickel(II cation and a square-planar nickel(II anion. Both the cation and the anion reside on a crystallographic center of inversion. The NiII center in the cation is coordinated by six pyrazol-1-yl rings of two chelating tripyrazol-1-ylmethane [HC(pz3] ligands, with Ni—N distances that range between 2.0647 (19 and 2.0828 (19 Å. The NiII center in the anion is coordinated by four cyanide ligands, with Ni—C distances in the range 1.869 (2–1.869 (3 Å. The [Ni(CN4]2− anions are linked by inversion-related water molecules into extended chains that run parallel to the a axis.

  12. Characterization of the pulse plasma source

    International Nuclear Information System (INIS)

    Milosavljevic, V; Karkari, S K; Ellingboe, A R

    2007-01-01

    Characterization of the pulse plasma source through the determination of the local thermodynamic equilibrium (LTE) threshold is described. The maximum electron density measured at the peak in discharge current is determined by the width of the He II Paschen alpha spectral line, and the electron temperature is determined from the ratios of the relative intensities of spectral lines emitted from successive ionized stages of atoms. The electron density and temperature maximum values are measured to be 1.3 x 10 17 cm -3 and 19 000 K, respectively. These are typical characteristics for low-pressure, pulsed plasma sources for input energy of 15.8 J at 130 Pa pressure in helium-argon mixture. The use of LTE-based analysis of the emission spectra is justified by measurement of the local plasma electron density at four positions in the discharge tube using a floating hairpin resonance probe. The hairpin resonance probe data are collected during the creation and decay phases of the pulse. From the spatio-temporal profile of the plasma density a 60 μs time-window during which LTE exists throughout the entire plasma source is determined

  13. Synthesis, characterization and antibacterial activity of some novel symmetrical n/sup 3/, n/sup 3/-bis(disubstituted)isophthalyl-bis(thioureas) and their Cu(II) and Ni(II) complexes

    International Nuclear Information System (INIS)

    Jamil, M.; Zubair, M.; Rasool, N.; Bukhari, I.H.; Farid, M.A.; Altaf, A.A.

    2013-01-01

    A series of some novel N/sup 3/,N/sup 3/-bis(disubstituted) isophthalyl-bis(thioureas) compounds with general formula (C/sub 6/H/sub 4/(CONHCSNHR)/sub 2/), where R = 4-C/sub 6/H/sub 4/COOH(L/sub 1/), 3-NO/sub 2/C/sub 6/H/sub 4/(L/sub 2/), 2-NO/sub 2/C/sub 6/H/sub 4/(L/sub 3/), 4-CH/sub 3/C/sub 6/H/sub 4/(L/sub 4/), 2-CH/sub 3/C/sub 6/H/sub 4/(L/sub 5/), 3-CH/sub 3/C/sub 6/H/sub 4/(L/sub 6/) and their Cu(II) and Ni(II) complexes have been synthesized. (L/sub 1/-L/sub 6/) have been prepared in good to excellent yields by reaction of isophthaloyl isothiocyanate with primary amines using dry acetone as solvent. The stoichiometric reaction between the metal (II) ion and synthesized ligands in molar ratio of M : L (1 : 1) resulted in the formation of the metal complexes of type (ML)2 (where M = Cu(II) and Ni(II). These compounds (L/sub 1/-L/sub 6/) and their metal (II) complexes have been characterized by elemental analyses, Infrared spectroscopy, /sup 1/H-NMR spectroscopy, magnetic moments, and electronic spectral measurements. These compounds (L/sub 1/-L/sub 6/) and their metal (II) complexes were also screened for their antibacterial activity against bacterial species, Bacillus subtilis, Staphylococcus aureus, Escherichia coli, Shigella sonnei, Salmonella typhi and Pseudomonas aeroginosa. Some compounds showed potential activity against a number of bacterial strains. The results of these studies also show the metal (II) complexes to be having stronger antibacterial activityl against one or more species as compared to the uncomplexed ligands. It was concluded that these compounds may be the potential source of active antibacterial agents. (author)

  14. Kilowatt isotope power system. Phase II plan. Volume I. Phase II program plan

    International Nuclear Information System (INIS)

    1978-01-01

    The development of a Kilowatt Isotope Power System (KIPS) was begun in 1975 for the purpose of satisfying the power requirements of satellites in the 1980's. The KIPS is a 238 PuO 2 -fueled organic Rankine cycle turbine power system to provide a design output of 500 to 2000 W. Phase II of the overall 3-phase KIPS program is described. This volume presents a program plan for qualifying the organic Rankine power system for flight test in 1982. The program plan calls for the design and fabrication of the proposed flight power system; conducting a development and a qualification program including both environmental and endurance testing, using an electrical and a radioisotope heat source; planning for flight test and spacecraft integration; and continuing ground demonstration system testing to act as a flight system breadboard and to accumulate life data

  15. Synthesis and properties of complexes of copper(II), nickel(II), cobalt(II) and uranyl ions with 3-(p-tolylsulphonamido)rhodamine

    International Nuclear Information System (INIS)

    El-Bindary, A.A.; El-Sonbati, A.Z.

    2000-01-01

    Metal complexes of copper(II), nickel(II), cobalt(II) and uranyl ions with 3-(p-tolylsulphonamido)rhodamine (HL) have been prepared and characterized by chemical and thermal analyses, molar conductivity , magnetic susceptibility measurements, and infrared, electronic and EPR spectra. The visible and EPR spectra indicated that the Cu(II) complex has a tetragonal geometry. From EPR spectrum of the Cu(II) complex,various parameters were calculated. The crystal field parameters of Ni(II) complex were calculated and were found to agree fairly well with the values reported for known square pyramidal complexes. The infrared spectral studies showed a monobasic bidentate behaviour with the oxygen and nitrogen donor system. Thermal stabilities of the complexes are also reported. (author)

  16. Adsorption study of cadmium (II) and lead (II) on radish peels

    International Nuclear Information System (INIS)

    Anwar, J.; Shafique, U.; Salman, M.; Zaman, W.; Memoona, M.

    2009-01-01

    The removal efficiency of heavy metals like Cd(II) and Pb(II) from aqueous solutions by adsorption on Raphanus sativus (Radish peels) has been studied. The effects of time, pH, concentration of adsorbent and agitation speed on adsorption have been evaluated. It is found that radish peels powder has high removal efficiency for both the metals. Batch adsorption study has shown that Cd(II) and Pb(II) has been removed up to 88% and 86% respectively. Adsorption equilibriums for both metals have been described by the Langmuir isotherm. The maximum amount of heavy metals (Q ) adsorbed at max equilibrium were 7.5 and 1.23 mg/g for Cd(II) and Pb(II) respectively as evaluated by Langmuir isotherm. It is concluded that waste materials like radish peels can be used for removal of heavy metals from aqueous streams. (author)

  17. Development and performance test of a new high power RF window in S-band PLS-II LINAC

    Science.gov (United States)

    Hwang, Woon-Ha; Joo, Young-Do; Kim, Seung-Hwan; Choi, Jae-Young; Noh, Sung-Ju; Ryu, Ji-Wan; Cho, Young-Ki

    2017-12-01

    A prototype of RF window was developed in collaboration with the Pohang Accelerator Laboratory (PAL) and domestic companies. High power performance tests of the single RF window were conducted at PAL to verify the operational characteristics for its application in the Pohang Light Source-II (PLS-II) linear accelerator (Linac). The tests were performed in the in-situ facility consisting of a modulator, klystron, waveguide network, vacuum system, cooling system, and RF analyzing equipment. The test results with Stanford linear accelerator energy doubler (SLED) have shown no breakdown up to 75 MW peak power with 4.5 μs RF pulse width at a repetition rate of 10 Hz. The test results with the current operation level of PLS-II Linac confirm that the RF window well satisfies the criteria for PLS-II Linac operation.

  18. Cytotoxicity and inhibitory properties against topoisomerase II of doxorubicin and its formamidine derivatives.

    Science.gov (United States)

    Kik, Krzysztof; Studzian, Kazimierz; Wasowska-Łukawska, Małgorzata; Oszczapowicz, Irena; Szmigiero, Leszek

    2009-01-01

    This work was undertaken to compare cytotoxicity, DNA damaging properties and effect on DNA cleavage by topoisomerase II of the anthracycline drug doxorubicin (DOX) and its two derivatives with a formamidino group containing a cyclic amine moiety such as morpholine (DOXM) or hexamethyleneimine (DOXH). The tetrazolium dye colorimetric assay was used to determine the cytotoxic activity of anthracyclines toward L1210 leukemia cells. DNA damage was measured by alkaline elution technique. The effect of anthracyclines on DNA cleavage was studied in a cell-free system containing supercoiled pBR322 DNA and purified human topoisomerase II. The cytotoxicity data and the results of studies on the mechanism of DNA break formation by anthracyclines at the cellular level and in the cell-free system showed that the presence of the formamidino group in the doxorubicin molecule reduced its ability to stimulate DNA cleavage by DNA topoisomerase II. DNA topoisomerase II is not a primary cellular target for DOXM or DOXH. An advantageous feature of formamidinoanthracyclines is their mechanism of cytotoxic action which is not related to the inhibition of DNA topoisomerase II. Therefore this class of anthracyclines seems to be a good source for selection of an anticancer drug directed toward cancer cells with the developed multidrug resistance attributed to the presence of altered DNA topoisomerase II.

  19. Studying the Interstellar Medium of H II/BCD Galaxies Using IFU Spectroscopy

    Directory of Open Access Journals (Sweden)

    Patricio Lagos

    2013-01-01

    Full Text Available We review the results from our studies, and previous published work, on the spatially resolved physical properties of a sample of H ii/BCD galaxies, as obtained mainly from integral-field unit spectroscopy with Gemini/GMOS and VLT/VIMOS. We confirm that, within observational uncertainties, our sample galaxies show nearly spatially constant chemical abundances similar to other low-mass starburst galaxies. They also show He ii  λ4686 emission with the properties being suggestive of a mix of excitation sources and with Wolf-Rayet stars being excluded as the primary ones. Finally, in this contribution, we include a list of all H ii/BCD galaxies studied thus far with integral-field unit spectroscopy.

  20. DUMAND-II (Deep Underwater Muon and Neutrino Detector) PROGRESS Report

    OpenAIRE

    Young, Kenneth K.

    1994-01-01

    The DUMAND-II detector will search for astronomical sources of high energy neutrinos. Successful deployment of the basic infrastructure, including the shore cable, the underwater junction box, and an environmental module was accomplished in December, 1993. One optical module string was also deployed and operated, logging data for about 10 hours. The underwater cable was connected to the shore station where we were able to successfully exercise system controls and log further environmental dat...

  1. Transverse feedback systems for the PEP-II B-factory

    International Nuclear Information System (INIS)

    Corlett, J.N.; Barry, W.; Byrd, J.M.; Lambertson, G.; Johnson, J.; Fahmie, M.

    1995-10-01

    Growth rates of coherent beam oscillations are faster than the natural damping mechanisms for the parameters of the PEP-II B-factory storage rings at nominal currents, even with damping of cavity higher order modes (HOM's). With 165 8 bunches separated by 4.2 ns, and a large current of up to 3A (2.14 A nominal in the low energy ring), many coupled-bunch modes are excited by the resistive wall impedance and cavity higher order mode impedance. Fastest growth times of transverse rigid-bunch modes of approximately 300 ps are expected, two orders of magnitude faster than the radiation damping time. We will provide broadband, bunch-by-bunch feedback to suppress this coherent motion of the beam. Experience gained with a prototype system, installed and successfully operating at the LBNL Advanced Light Source (ALS), has been used extensively in developing the design of the PEP-II systems

  2. Ionizing nightglow: sources, intensity, and spatial distribution

    International Nuclear Information System (INIS)

    Young, J.M.; Troy, B.E. Jr.; Johnson, C.Y.; Holmes, J.C.

    1975-01-01

    Photometers carried aboard an Aerobee rocket mapped the ultraviolet night sky at White Sands, New Mexico. Maps for five 300 A passbands in the wavelength range 170 to 1400 A reveal spatial radiation patterns unique to each spectral subregion. The major ultraviolet features seen in these maps are ascribed to a variety of sources: 1) solar Lyman α (1216 A) and Lyman β (1026 A), resonantly scattered by geocoronal hydrogen; 2) solar HeII (304 A) resonantly scattered by ionized helium in the Earth's plasmasphere; 3) solar HeI (584 A) resonantly scattered by neutral helium in the interstellar wind and Doppler shifted so that it penetrates the Earth's helium blanket; and 4) starlight in the 912 to 1400 A band, primarily from early-type stars in the Orion region. Not explained are the presence of small, but measurable, albedo signals observed near the peak of flight. Intensities vary from several kilorayleighs for Lyman α to a few rayleighs for HeII. (auth)

  3. New complexes of Co(II, Ni(II, Cu(II with Schiff base N,N’-bis-(3-methoxy-saliciliden-3,3’-dimethylbenzidine

    Directory of Open Access Journals (Sweden)

    Alan Ionela

    2013-01-01

    Full Text Available The new N,N’-bis-(3-methoxy-saliciliden-3,3’-dimetilbenzidine (H2L Schiff base and complexes with Co(II, Ni(II and Cu(II of type [M(HLCl(H2O] (M=Co(II, Cu(II [M2L(H2O4]X2 (M=Co(II, X=ClO4 and M=Cu(II, X=NO3 and [M2L(CH3COO2] (M=Co(II, Ni(II, Cu(II were synthesised. The ligand and complexes were characterized by elemental analysis, conductibility measurements, magnetic moments at room temperature, IR, NMR, UV-VIS-NIR, EPR spectra and thermogravimetric analysis. A molar ratio of 1:1 or 1:2 between ligand and metal was determined from the elemental analysis. Except for perchlorate complex that behave as electrolyte, the rest of complexes are non-electrolytes. The spectral data suggest a tetrahedral, pseudo-tetrahedral or square-planar stereochemistry respectively, data confirmed by magnetic behaviour of complexes. The antimicrobial tests indicate a fungicide effect both for ligand and complexes.

  4. Laser power meters as an X-ray power diagnostic for LCLS-II.

    Science.gov (United States)

    Heimann, Philip; Moeller, Stefan; Carbajo, Sergio; Song, Sanghoon; Dakovski, Georgi; Nordlund, Dennis; Fritz, David

    2018-01-01

    For the LCLS-II X-ray instruments, laser power meters are being developed as compact X-ray power diagnostics to operate at soft and tender X-ray photon energies. These diagnostics can be installed at various locations along an X-ray free-electron laser (FEL) beamline in order to monitor the transmission of X-ray optics along the beam path. In addition, the power meters will be used to determine the absolute X-ray power at the endstations. Here, thermopile power meters, which measure average power, and have been chosen primarily for their compatibility with the high repetition rates at LCLS-II, are evaluated. A number of characteristics in the soft X-ray range are presented including linearity, calibrations conducted with a photodiode and a gas monitor detector as well as ultra-high-vacuum compatibility tests using residual gas analysis. The application of these power meters for LCLS-II and other X-ray FEL sources is discussed.

  5. A SUBSTELLAR COMMON PROPER-MOTION COMPANION TO THE PLEIAD H II 1348

    International Nuclear Information System (INIS)

    Geißler, Kerstin; Metchev, Stanimir A.; Pham, Alfonse; Larkin, James E.; McElwain, Michael; Hillenbrand, Lynne A.

    2012-01-01

    We announce the identification of a proper-motion companion to the star H II 1348, a K5 V member of the Pleiades open cluster. The existence of a faint point source 1.''1 away from H II 1348 was previously known from adaptive optics imaging by Bouvier et al. However, because of a high likelihood of background star contamination and in the absence of follow-up astrometry, Bouvier et al. tentatively concluded that the candidate companion was not physically associated with H II 1348. We establish the proper-motion association of the pair from adaptive optics imaging with the Palomar 5 m telescope. Adaptive optics spectroscopy with the integral field spectrograph OSIRIS on the Keck 10 m telescope reveals that the companion has a spectral type of M8 ± 1. According to substellar evolution models, the M8 spectral type resides within the substellar mass regime at the age of the Pleiades. The primary itself is a known double-lined spectroscopic binary, which makes the resolved companion, H II 1348B, the least massive and widest component of this hierarchical triple system and the first substellar companion to a stellar primary in the Pleiades.

  6. Modeling geochemical datasets for source apportionment: Comparison of least square regression and inversion approaches.

    Digital Repository Service at National Institute of Oceanography (India)

    Tripathy, G.R.; Das, Anirban.

    used methods, the Least Square Regression (LSR) and Inverse Modeling (IM), to determine the contributions of (i) solutes from different sources to global river water, and (ii) various rocks to a glacial till. The purpose of this exercise is to compare...

  7. and copper(II)

    Indian Academy of Sciences (India)

    Unknown

    (II) and copper(II)–zinc(II) complexes. SUBODH KUMAR1, R N PATEL1*, P V KHADIKAR1 and. K B PANDEYA2. 1 Department of Chemistry, APS University, Rewa 486 003, India. 2 CSJM University, Kanpur 208 016, India e-mail: (R N Patel) ...

  8. Space-time structure of neutron and X-ray sources in a plasma focus

    International Nuclear Information System (INIS)

    Bostick, W.H.; Nardi, V.; Prior, W.

    1977-01-01

    Systematic measurements with paraffin collimators of the neutron emission intensity have been completed on a plasma focus with a 15-20 kV capacitor bank (hollow centre electrode; discharge period T approximately 8 μs; D 2 filling at 4-8 torr). The space resolution was 1 cm or better. These data indicate that at least 70% of the total neutron yield originates within hot-plasma regions where electron beams and high-energy D beams (approximately > 0.1-1 MeV) are produced. The neutron source is composed of several (approximately > 1-10) space-localized sources of different intensity, each with a duration approximately less than 5 ns (FWHM). Localized neutron sources and hard (approximately > 100 keV) X-ray sources have the same time multiplicity and are usually distributed in two groups over a time interval 40-400 ns long. By the mode of operation used by the authors one group of localized sources (Burst II) is observed 200-400 ns after the other group (Burst I) and its space distribution is broader than for Burst I. The maximum intensity of a localized source of neutrons in Burst I is much higher than the maximum intensity in Burst II. Secondary reactions T(D,n) 4 He (from the tritium produced only by primary reactions in the same discharge; no tritium was used in filling the discharge chamber) are observed in a time coincidence with the strongest D-D neutron pulse of Burst I. The neutron signal from a localized source with high intensity has a relatively long tail of small amplitude (area tail approximately less than 0.2 X area peak). This tail can be generated by the D-D reactions of the unconfined part of an ion beam in the cold plasma. Complete elimination of scattered neutrons on the detector was achieved in these measurements. (author)

  9. Determination of Lead(II), Cadmium(II) and Copper(II) in Waste-Water and Soil Extracts on Mercury Film Screen-Printed Carbon Electrodes Sensor

    International Nuclear Information System (INIS)

    Mohd Fairulnizal Md Noh; Tothill, I.E.

    2011-01-01

    A sensor incorporating a three electrodes configuration have been fabricated using low cost screen-printing technology. These electrodes couples with Square Wave Stripping Voltammetry (SWSV) has provided a convenient screening tool for on-site detection of trace levels of Pb(II), Cd(II) and Cu(II). Modification of the graphite carbon surface based on in situ deposition of mercury film has been carried out. By appropriate choice of supporting medium and optimized parameters setting such as amount of mercury used the deposition potential, deposition time, frequency and scan rate, well resolved and reproducible response for Pb(II), Cd(II) and Cu(II) were obtained. The performance characteristics of the developed mercury film screen printed carbon electrode (MFSPCE) for 120 s deposition time showed that the linear range for Cd(II), Pb(II) and Cu(II) were 10 to 200 μg L -1 . The detection limit recorded for Cd(II), Pb(II) and Cu(II) were 2, 1 and 5 μg L -1 with relative standard deviation (RSD) of 6.5 %, 6.9 % and 7.5 %, respectively. Successful applications of the sensing device to waste-water and extracted soil samples were demonstrated. (author)

  10. Spectral energy distribution analysis of class I and class II FU Orionis stars

    Energy Technology Data Exchange (ETDEWEB)

    Gramajo, Luciana V.; Gómez, Mercedes [Observatorio Astronómico, Universidad Nacional de Córdoba, Argentina, Laprida 854, 5000 Córdoba (Argentina); Rodón, Javier A., E-mail: luciana@oac.uncor.edu, E-mail: mercedes@oac.uncor.edu, E-mail: jrodon@eso.org [European Southern Observatory, Alonso de Córdova 3107, Vitacura, Casilla 19001, Santiago 19 (Chile)

    2014-06-01

    FU Orionis stars (FUors) are eruptive pre-main sequence objects thought to represent quasi-periodic or recurring stages of enhanced accretion during the low-mass star-forming process. We characterize the sample of known and candidate FUors in a homogeneous and consistent way, deriving stellar and circumstellar parameters for each object. We emphasize the analysis in those parameters that are supposed to vary during the FUor stage. We modeled the spectral energy distributions of 24 of the 26 currently known FUors, using the radiative transfer code of Whitney et al. We compare our models with those obtained by Robitaille et al. for Taurus class II and I sources in quiescence periods by calculating the cumulative distribution of the different parameters. FUors have more massive disks: we find that ∼80% of the disks in FUors are more massive than any Taurus class II and I sources in the sample. Median values for the disk mass accretion rates are ∼10{sup –7} M {sub ☉} yr{sup –1} versus ∼10{sup –5} M {sub ☉} yr{sup –1} for standard young stellar objects (YSOs) and FUors, respectively. While the distributions of envelope mass accretion rates for class I FUors and standard class I objects are similar, FUors, on average, have higher envelope mass accretion rates than standard class II and class I sources. Most FUors (∼70%) have envelope mass accretion rates above 10{sup –7} M {sub ☉} yr{sup –1}. In contrast, 60% of the classical YSO sample has an accretion rate below this value. Our results support the current scenario in which changes experimented by the circumstellar disk explain the observed properties of these stars. However, the increase in the disk mass accretion rate is smaller than theoretically predicted, although in good agreement with previous determinations.

  11. Nuclear-Recoil Energy Scale in CDMS II Silicon Dark-Matter Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Agnese, R.; et al.

    2018-03-07

    The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.

  12. Wormhole solutions sourced by fluids, I: Two-fluid charged sources

    Energy Technology Data Exchange (ETDEWEB)

    Azreg-Ainou, Mustapha [Baskent University, Faculty of Engineering, Ankara (Turkey)

    2016-01-15

    We briefly discuss some of the known and new properties of rotating geometries that are relevant to this work. We generalize the analytical method of superposition of fields, known for generating nonrotating solutions, and apply it to construct massless and massive rotating physical wormholes sourced by a source-free electromagnetic field and an exotic fluid both anisotropic. Their stress-energy tensors are presented in compact and general forms. For the massive rotating wormholes there exists a mass-charge constraint yielding almost no more dragging effects than ordinary stars. There are conical spirals through the throat along which no local negative energy densities are noticed for these rotating wormholes. This conclusion extends to nonrotating massive type I wormholes derived previously by the author, which seem to be the first kind of nonrotating wormholes with this property. Based on the classification made in Azreg-Ainou (J Cosmol Astropart Phys 07:037, arXiv:1412.828 [gr-qc], 2015): ''Type I wormholes have their radial pressure dying out faster, as one moves away from the throat, than any other component of the stress-energy and thus violate the least the local energy conditions. In type II (resp. III) the radial and transverse pressures are asymptotically proportional and die out faster (resp. slower) than the energy density''. (orig.)

  13. Kinetic and spectroscopic investigation of CoII, NiII, and N-oxalylglycine inhibition of the FeII/α-ketoglutarate dioxygenase, TauD

    International Nuclear Information System (INIS)

    Kalliri, Efthalia; Grzyska, Piotr K.; Hausinger, Robert P.

    2005-01-01

    Co II , Ni II , and N-oxalylglycine (NOG) are well-known inhibitors of Fe II /α-ketoglutarate (αKG)-dependent hydroxylases, but few studies describe their kinetics and no spectroscopic investigations have been reported. Using taurine/αKG dioxygenase (TauD) as a paradigm for this enzyme family, time-dependent inhibition assays showed that Co II and Ni II follow slow-binding inhibition kinetics. Whereas Ni II -substituted TauD was non-chromophoric, spectroscopic studies of the Co II -substituted enzyme revealed a six-coordinate site (protein alone or with αKG) that became five-coordinate upon taurine addition. The Co II spectrum was not perturbed by a series of anions or oxidants, suggesting the Co II is inaccessible and could be used to stabilize the protein. NOG competed weakly (K i ∼ 290 μM) with αKG for binding to TauD, with the increased electron density of NOG yielding electronic transitions for NOG-Fe II -TauD and taurine-NOG-Fe II -TauD at 380 nm (ε 38 90-105 M -1 cm -1 ). The spectra of the NOG-bound TauD species did not change significantly upon oxygen exposure, arguing against the formation of an oxygen-bound state mimicking an early intermediate in catalysis

  14. ASPHERICITY, INTERACTION, AND DUST IN THE TYPE II-P/II-L SUPERNOVA 2013EJ IN MESSIER 74

    Energy Technology Data Exchange (ETDEWEB)

    Mauerhan, Jon C.; Graham, Melissa L.; Filippenko, Alexei V.; Shivvers, Isaac [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States); Van Dyk, Schuyler D. [Infrared Processing and Analysis Center, California Institute of Technology, 1200 E. California Boulevard, Pasadena, CA 91125 (United States); Johansson, Joel [Department of Particle Physics and Astrophysics, Weizmann Institute of Science, 234 Herzl St., Rehovot (Israel); Hu, Maokai; Wang, Lifan [Department of Physics, Texas A and M University, College Station, TX 77843 (United States); Fox, Ori D., E-mail: mauerhan@astro.berkeley.edu [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2017-01-10

    SN 2013ej is a well-studied core-collapse supernova (SN) that stemmed from a directly identified red supergiant (RSG) progenitor in galaxy M74. The source exhibits signs of substantial geometric asphericity, X-rays from persistent interaction with circumstellar material (CSM), thermal emission from warm dust, and a light curve that appears intermediate between supernovae of Types II-P and II-L. The proximity of this source motivates a close inspection of these physical characteristics and their potential interconnection. We present multiepoch spectropolarimetry of SN 2013ej during the first 107 days and deep optical spectroscopy and ultraviolet through infrared photometry past ∼800 days. SN 2013ej exhibits the strongest and most persistent continuum and line polarization ever observed for a SN of its class during the recombination phase. Modeling indicates that the data are consistent with an oblate ellipsoidal photosphere, viewed nearly edge-on and probably augmented by optical scattering from circumstellar dust. We suggest that interaction with an equatorial distribution of CSM, perhaps the result of binary evolution, is responsible for generating the photospheric asphericity. Relatedly, our late-time optical imaging and spectroscopy show that asymmetric CSM interaction is ongoing, and the morphology of broad H α emission from shock-excited ejecta provides additional evidence that the geometry of the interaction region is ellipsoidal. Alternatively, a prolate ellipsoidal geometry from an intrinsically bipolar explosion is also a plausible interpretation of the data but would probably require a ballistic jet of radioactive material capable of penetrating the hydrogen envelope early in the recombination phase. Finally, our latest space-based optical imaging confirms that the late interaction-powered light curve dropped below the stellar progenitor level, confirming the RSG star’s association with the explosion.

  15. II-VI semiconductor compounds

    CERN Document Server

    1993-01-01

    For condensed matter physicists and electronic engineers, this volume deals with aspects of II-VI semiconductor compounds. Areas covered include devices and applications of II-VI compounds; Co-based II-IV semi-magnetic semiconductors; and electronic structure of strained II-VI superlattices.

  16. Development of a Single Detector Ring Micro Crystal Element Scanner: QuickPET II

    Directory of Open Access Journals (Sweden)

    Robert S. Miyaoka

    2005-04-01

    Full Text Available This article describes a single ring version of the micro crystal element scanner (MiCES and investigation of its spatial resolution imaging characteristics for mouse positron emission tomography (PET imaging. This single ring version of the MiCES system, referred to as QuickPET II, consists of 18 MiCE detector modules mounted as a single ring in a vertical gantry. The system has a 5.76-cm transverse field of view and a 1.98-cm axial field of view. In addition to the scanner and data acquisition system, we have developed an iterative reconstruction that includes a model of the system's detector response function. Evaluation images of line sources and mice have been acquired. Using filtered backprojection, the resolution for a reconstructed line source has been measured at 1.2 mm full width at half maximum. F-18-2-fluoro-2-deoxyglucose mouse PET images are provided. The result shows that QuickPET II has the imaging characteristics to support high-resolution, static mouse PET studies using 18-F labeled compounds.

  17. The klystron: A microwave source of surprising range and endurance

    International Nuclear Information System (INIS)

    Caryotakis, G.

    1998-04-01

    This year marks the 60th anniversary of the birth of the klystron at Stanford University. The tube was the first practical source of microwaves and its invention initiated a search for increasingly more powerful sources, which continues to this day. This paper reviews the scientific uses of the klystron and outlines its operating principles. The history of the device is traced, from its scientific beginnings, to its role in World War II and the Cold War, and to its current resurgence as the key component in a major accelerator project. Finally, the paper describes the development of a modular klystron, which may someday power future accelerators at millimeter wavelengths

  18. Syntheses, structures, and properties of imidazolate-bridged Cu(II)-Cu(II) and Cu(II)-Zn(II) dinuclear complexes of a single macrocyclic ligand with two hydroxyethyl pendants.

    Science.gov (United States)

    Li, Dongfeng; Li, Shuan; Yang, Dexi; Yu, Jiuhong; Huang, Jin; Li, Yizhi; Tang, Wenxia

    2003-09-22

    The imidazolate-bridged homodinuclear Cu(II)-Cu(II) complex, [(CuimCu)L]ClO(4).0.5H(2)O (1), and heterodinuclear Cu(II)-Zn(II) complex, [(CuimZnL(-)(2H))(CuimZnL(-)(H))](ClO(4))(3) (2), of a single macrocyclic ligand with two hydroxyethyl pendants, L (L = 3,6,9,16,19,22-hexaaza-6,19-bis(2-hydroxyethyl)tricyclo[22,2,2,2(11,14)]triaconta-1,11,13,24,27,29-hexaene), have been synthesized as possible models for copper-zinc superoxide dismutase (Cu(2),Zn(2)-SOD). Their crystal structures analyzed by X-ray diffraction methods have shown that the structures of the two complexes are markedly different. Complex 1 crystallizes in the orthorhombic system, containing an imidazolate-bridged dicopper(II) [Cu-im-Cu](3+) core, in which the two copper(II) ions are pentacoordinated by virtue of an N4O environment with a Cu.Cu distance of 5.999(2) A, adopting the geometry of distorted trigonal bipyramid and tetragonal pyramid, respectively. Complex 2 crystallizes in the triclinic system, containing two similar Cu-im-Zn cores in the asymmetric unit, in which both the Cu(II) and Zn(II) ions are pentacoordinated in a distorted trigonal bipyramid geometry, with the Cu.Zn distance of 5.950(1)/5.939(1) A, respectively. Interestingly, the macrocyclic ligand with two arms possesses a chairlike (anti) conformation in complex 1, but a boatlike (syn) conformation in complex 2. Magnetic measurements and ESR spectroscopy of complex 1 have revealed the presence of an antiferromagnetic exchange interaction between the two Cu(II) ions. The ESR spectrum of the Cu(II)-Zn(II) heterodinuclear complex 2 displayed a typical signal for mononuclear trigonal bipyramidal Cu(II) complexes. From pH-dependent ESR and electronic spectroscopic studies, the imidazolate bridges in the two complexes have been found to be stable over broad pH ranges. The cyclic voltammograms of the two complexes have been investigated. Both of the two complexes can catalyze the dismutation of superoxide and show rather high activity.

  19. Syntheses of polystyrene supported chelating resin containing the Schiff base derived from salicylaldehyde and triethylene tetramine and its copper(II), nickel(II), cobalt(II), iron(III), zinc(II), cadmium(II), molybdenum(VI), zirconium(IV) and uranium(VI) complexes

    International Nuclear Information System (INIS)

    Syamal, A.; Singh, M.M.

    1998-01-01

    A new polymer-anchored chelating ligand has been synthesized by the reaction of chloromethylated polystyrene (containing 0.94 mmol of Cl per gram of resin and 1% cross-linked with divinylbenzene) and the Schiff base derived from salicylaldehyde and triethylenetetramine. A new series of polystyrene supported, Cu(II), Ni(II), Co(II), Fe(III), Zn(II), Cd(II), Zr(IV), dioxomolybdenum (VI) and dioxouranium (VI) complexes of the formulae PS-LCu, PS-LNi, PS-LCo, PS-LFeCl.DMF, PS-LZn, PS-LCd, PS-LZr(OH) 2 . DMF, PS L MoO 2 and PS-LUO 2 (where PS-LH 2 = polymer-anchored Schiff base and DMF dimethyl-formamide) have been synthesized and characterised by elemental analysis, infrared, electronic spectra and magnetic susceptibility measurements. The complexes PS-LCu, PS-LNi and PS-LCo have square planar structure, PS-LFeCl.DMF, PS-LMoO 2 and PS-LUO 2 have octahedral structure, PS L Zn and PS-LCd are tetrahedral and PS-LZr(OH) 2 .DMF is pentagonal bipyramidal. The polymer-anchored Cu(II), Co(II) and Fe(III) complexes are paramagnetic while Ni(II), Zn(II), Cd(II), Zr(IV), dioxomolybdenum(VI) and dioxouranium(VI) complexes are diamagnetic. The negative shift of the v (C=N) (azomethine) and the positive shift of v (C--O)(phenolic) are indicative of ONNO donor behaviour of the polymer-anchored Schiff base. (author)

  20. DNA binding and biological activity of mixed ligand complexes of Cu(II, Ni(II and Co(II with quinolones and N donor ligand

    Directory of Open Access Journals (Sweden)

    S.M M Akram

    2015-10-01

    Full Text Available  AbstractMixed ligand complexes of  Cu(II, Ni(II and Co(II have been synthesized by using levofloxacin and bipyridyl and characterized using spectral and analytical techniques. The binding behavior of the Ni(II and Cu(II complexes with herring sperm DNA(Hs-DNA were determined using electronic absorption titration, viscometric measurements and cyclic voltammetry measurements. The binding constant calculated  for Cu(II and Ni(II complexes are 2.0 x 104 and 4.0 x 104 M-1 respectively. Detailed analysis reveals that these metal complexes interact with DNA through intercalative binding mode. The nuclease activity of  Cu(II and Ni(II complexes with ct-DNA was carried out using agarose gel electrophoresis technique. The antioxidant activities for the synthesized complexes have been tested and the antibacterial activity for Ni(II complex was also checked.Key words: Intercalation, hypochromism, red shift and  peak potential.

  1. Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX)

    International Nuclear Information System (INIS)

    Roy, Prabir K.; Greenway, Wayne G.; Kwan, Joe W.; Seidl, Peter A.; Waldron, William L.; Wu, James K.

    2010-01-01

    We report results on lithium alumino-silicate ion source development in preparation for warm-dense-matter heating experiments on the new Neutralized Drift Compression Experiment (NDCX-II). The practical limit to the current density for a lithium alumino-silicate source is determined by the maximum operating temperature that the ion source can withstand before running into problems of heat transfer, melting of the alumino-silicate material, and emission lifetime. Using small prototype emitters, at a temperature of ∼1275 C, a space-charge-limited Li + beam current density of J ∼1 mA/cm 2 was obtained. The lifetime of the ion source was ∼50 hours while pulsing at a rate of 0.033 Hz with a pulse duration of 5-6 (micro) s.

  2. WASTES II: Waste System Transportation and Economic Simulation. Version II. User's guide

    International Nuclear Information System (INIS)

    Shay, M.R.; Buxbaum, M.E.

    1986-02-01

    The WASTES II model was developed to provide detailed analyses beyond the capabilities of other available models. WASTES uses discrete event simulation techniques to model the generation of commercial spent nuclear fuel, the buildup of spent fuel inventories within the system, and the transportation requirements for the movement of radioactive waste throughout the system. The model is written in FORTRAN 77 as an extension to the SLAM commercial simulation language package. In addition to the pool storage and dry storage located at the reactors, the WASTES model provides a choice of up to ten other storage facilities of four different types. The simulation performed by WASTES may be controlled by a combination of source- and/or destination-controlled transfers that are requested by the code user. The user supplies shipping cask characteristics for truck or rail shipment casks. As part of the facility description, the user specifies which casks the facility can use. Shipments within the system can be user specified to occur optimally, or proximally. Optimized shipping can be used when exactly two destination facilities of the same facility type are open for receipt of fuel. Optimized shipping selects source/destination pairs so that the total shipping distance or total shipping costs in a given year are minimized when both facilities are fully utilized. Proximity shipping sequentially fills the closest facility to the source according to the shipment priorities without regard for the total annual shipments. This results in sub-optimal routing of waste material but can be used to approximate an optimal shipping strategy when more than two facilities of the same type are available to receive waste. WASTES is currently able to analyze each of the commercial spent fuel logistics scenarios specified in the 1985 DOE Mission Plan

  3. Mixed ligand complexes of alkaline earth metals: Part XII. Mg(II, Ca(II, Sr(II and Ba(II complexes with 5-chlorosalicylaldehyde and salicylaldehyde or hydroxyaromatic ketones

    Directory of Open Access Journals (Sweden)

    MITHLESH AGRAWAL

    2002-04-01

    Full Text Available The reactions of alkaline earth metal chlorides with 5-chlorosalicylaldehyde and salicylaldehyde, 2-hydroxyacetophenone or 2-hydroxypropiophenone have been carried out in 1 : 1 : 1 mole ratio and the mixed ligand complexes of the type MLL’(H2O2 (where M = Mg(II, Ca(II, Sr(II and Ba(II, HL = 5-chlorosalicylaldehyde and HL’ = salicylaldehyde, 2-hydroxyacetophenone or 2-hydroxypropiophenone have been isolated. These complexes were characterized by TLC, conductance measurements, IR and 1H-NMR spectra.

  4. Radio recombination lines from H II regions

    International Nuclear Information System (INIS)

    Silverglate, P.R.

    1978-01-01

    Radio recombination lines have been observed from forty-six H II regions. The Arecibo 1000-foot radio telescope was used to provide high sensitivity and high angular resolution at 1400 MHz (gain approx. 7.7 0 K/Jy, HPBW = 3:2) and 2372 MHZ (gain approx. 6.3 0 K/Jy, HPBW = 2'). Observations were made at 1400 MHz in the frequency switching mode, and at 2372 MHz in the total power mode. Gaussians were fit to be observed lines to derive velocities, line widths, and line temperatures. From the velocities kinematic distances were derived. For eleven sources H I absorption measurements were also made. The absorption spectra enabled the kinematic distance ambiguity to be resolved for some sources. The absorption spectra themselves were found to have extremely sharp, non-gaussian edges. One explanation for these is a model where the interstellar medium contains many H I cloudlets with T/sub s/less than or equal to 100 0 K and turbulent velocities less than or equal to 3 km/s. The H I absorption spectrum is then a superposition of many narrow gaussian profiles. It was also found from a comparison of H I absorption velocities with radio recombination line velocities that peculiar motions exist in the interstellar medium with velocities of up to 10 km/s. Using the measured line temperatures and continuum temperatures, estimates were desired of emission measures, electron temperatures, and electron densities, using a non-LTE analysis. Non-LTE effects were important only for the hottest and densest H II regions. The non-LTE calculations were checked through a comparison derivation of electron temperatures using hydrogen beta lines

  5. Strengthening control over radioactive sources in authorized use and regaining control over orphan sources. National strategies

    International Nuclear Information System (INIS)

    2004-02-01

    The objective of this report is to provide practical guidance to States on the development of a national strategy for improving control over radioactive sources, particularly dangerous sources (Categories 1-3). Part of this process involves the determination of the magnitude of the potential problem with orphan and vulnerable sources and indeed, whether or not a national strategy is needed. The ultimate objective is that States will use this report to develop and then implement a plan of action that will result in all significant sources being managed in a safe and secure manner. This report attempts to provide both the background knowledge and the methodology necessary for an individual or small team of responsible persons to develop a national strategy for improving control over all radioactive sources, but especially orphan and vulnerable sources. The background knowledge given in Chapter 3 is an update of the information on practices that was given in IAEA-TECDOC-804, which focused on spent radioactive sources. After some introductory material, this report provides both the factual information and the general steps needed to develop and implement a national strategy. Part I contains background information for those who are not already familiar with the subject including the need for national strategies, the generic causes of loss of control of sources, with specific examples and the common applications of radioactive sources. Part II details the actual process for the development and implementation of a national strategy, which includes assessing the problem by first gathering specific and national information, determining the nature and magnitude of the problem, developing the national strategy by evaluating, and prioritizing possible solutions, implementing the strategy subsequent to a high level decision; and evaluating the effectiveness of the plan and making changes as a result until the desired objective is achieved. Searches for sources will be part of

  6. Multiband counterparts of two eclipsing ultraluminous X-ray sources in M 51

    Science.gov (United States)

    Urquhart, R.; Soria, R.; Johnston, H. M.; Pakull, M. W.; Motch, C.; Schwope, A.; Miller-Jones, J. C. A.; Anderson, G. E.

    2018-04-01

    We present the discovery and interpretation of ionized nebulae around two ultraluminous X-ray sources in M 51; both sources share the rare property of showing X-ray eclipses by their companion stars and are therefore prime targets for follow-up studies. Using archival Hubble Space Telescope images, we found an elongated, 100-pc-long emission-line structure associated with one X-ray source (CXOM51 J132940.0+471237; ULX-1 for simplicity), and a more circular, ionized nebula at the location of the second source (CXOM51 J132939.5+471244; ULX-2 for simplicity). We observed both nebulae with the Large Binocular Telescope's Multi-Object Double Spectrograph. From our analysis of the optical spectra, we argue that the gas in the ULX-1 bubble is shock-ionized, consistent with the effect of a jet with a kinetic power of ≈2 × 1039 erg s-1. Additional X-ray photoionization may also be present, to explain the strength of high-ionization lines such as He II λ4686 and [Ne V] λ3426. On the other hand, the emission lines from the ULX-2 bubble are typical for photoionization by normal O stars suggesting that the nebula is actually an H II region not physically related to the ULX but is simply a chance alignment. From archival Very Large Array data, we also detect spatially extended, steep-spectrum radio emission at the location of the ULX-1 bubble (consistent with its jet origin), but no radio counterpart for ULX-2 (consistent with the lack of shock-ionized gas around that source).

  7. Wind bubbles within H ii regions around slowly moving stars

    Science.gov (United States)

    Mackey, Jonathan; Gvaramadze, Vasilii V.; Mohamed, Shazrene; Langer, Norbert

    2015-01-01

    Interstellar bubbles around O stars are driven by a combination of the star's wind and ionizing radiation output. The wind contribution is uncertain because the boundary between the wind and interstellar medium is difficult to observe. Mid-infrared observations (e.g., of the H ii region RCW 120) show arcs of dust emission around O stars, contained well within the H ii region bubble. These arcs could indicate the edge of an asymmetric stellar wind bubble, distorted by density gradients and/or stellar motion. We present two-dimensional, radiation-hydrodynamics simulations investigating the evolution of wind bubbles and H ii regions around massive stars moving through a dense (nH = 3000 cm-3), uniform medium with velocities ranging from 4 to 16 km s-1. The H ii region morphology is strongly affected by stellar motion, as expected, but the wind bubble is also very aspherical from birth, even for the lowest space velocity considered. Wind bubbles do not fill their H ii regions (we find filling factors of 10-20 per cent), at least for a main sequence star with mass M⋆ ~ 30 M⊙. Furthermore, even for supersonic velocities the wind bow shock does not significantly trap the ionization front. X-ray emission from the wind bubble is soft, faint, and comes mainly from the turbulent mixing layer between the wind bubble and the H ii region. The wind bubble radiates <1 per cent of its energy in X-rays; it loses most of its energy by turbulent mixing with cooler photoionized gas. Comparison of the simulations with the H ii region RCW 120 shows that its dynamical age is ≲0.4 Myr and that stellar motion ≲4 km s-1 is allowed, implying that the ionizing source is unlikely to be a runaway star but more likely formed in situ. The region's youth, and apparent isolation from other O or B stars, makes it very interesting for studies of massive star formation and of initial mass functions. Movies are available in electronic form at http://www.aanda.org

  8. Neutrinoless double beta decay in type I+II seesaw models

    Energy Technology Data Exchange (ETDEWEB)

    Borah, Debasish [Department of Physics, Tezpur University,Tezpur-784028 (India); Dasgupta, Arnab [Institute of Physics, Sachivalaya Marg,Bhubaneshwar-751005 (India)

    2015-11-30

    We study neutrinoless double beta decay in left-right symmetric extension of the standard model with type I and type II seesaw origin of neutrino masses. Due to the enhanced gauge symmetry as well as extended scalar sector, there are several new physics sources of neutrinoless double beta decay in this model. Ignoring the left-right gauge boson mixing and heavy-light neutrino mixing, we first compute the contributions to neutrinoless double beta decay for type I and type II dominant seesaw separately and compare with the standard light neutrino contributions. We then repeat the exercise by considering the presence of both type I and type II seesaw, having non-negligible contributions to light neutrino masses and show the difference in results from individual seesaw cases. Assuming the new gauge bosons and scalars to be around a TeV, we constrain different parameters of the model including both heavy and light neutrino masses from the requirement of keeping the new physics contribution to neutrinoless double beta decay amplitude below the upper limit set by the GERDA experiment and also satisfying bounds from lepton flavor violation, cosmology and colliders.

  9. Intrafibrillar Mineral May be Absent in Dentinogenesis Imperfecta Type II (DI-II)

    Energy Technology Data Exchange (ETDEWEB)

    Pople, John A

    2001-03-29

    High-resolution synchrotron radiation computed tomography (SRCT) and small angle x-ray scattering (SAXS) were performed on normal and dentinogenesis imperfecta type II (DI-II) teeth. Three normal and three DI-II human third molars were used in this study. The normal molars were unerupted and had intact enamel; donors were female and ranged in age from 18-21y. The DI-II specimens, which were also unerupted with intact enamel, came from a single female donor age 20y. SRCT showed that the mineral concentration was 33% lower on average in the DI-II dentin with respect to normal dentin. The SAXS spectra from normal dentin exhibited low-angle diffraction peaks at harmonics of 67.6 nm, consistent with nucleation and growth of the apatite phase within gaps in the collagen fibrils (intrafibrillar mineralization). In contrast, the low-angle peaks were almost nonexistent in the DI-II dentin. Crystallite thickness was independent of location in both DI-II and normal dentin, although the crystallites were significantly thicker in DI-II dentin (6.8 nm (s.d. = 0.5) vs 5.1 nm (s.d. = 0.6)). The shape factor of the crystallites, as determined by SAXS, showed a continuous progression in normal dentin from roughly one-dimensional (needle-like) near the pulp to two-dimensional (plate-like) near the dentin-enamel junction. The crystallites in DI-II dentin, on the other hand, remained needle-like throughout. The above observations are consistent with an absence of intrafibrillar mineral in DI-II dentin.

  10. Adsorption of Cu(II), Hg(II), and Ni(II) ions by modified natural wool chelating fibers

    International Nuclear Information System (INIS)

    Monier, M.; Ayad, D.M.; Sarhan, A.A.

    2010-01-01

    The graft copolymerization of ethyl acrylate (EA) onto natural wool fibers initiated by potassium persulphate and Mohr's salt redox initiator system in limited aqueous medium was carried out in heterogeneous media. Ester groups of the grafted copolymers were partially converted into hydrazide function groups followed by hydrazone formation through reaction with isatin. Also the application of the modified fibers for metal ion uptake was studied using Cu(II), Hg(II) and Ni(II). The modified chelating fibers were characterized using FTIR spectroscopy, SEM and X-ray diffraction.

  11. Fractional distillation as a strategy for reducing the genotoxic potential of SRC-II coal liquids: a status report

    Energy Technology Data Exchange (ETDEWEB)

    Pelroy, R.A.; Wilson, B.W.

    1981-09-01

    This report presents results of studies on the effects of fractional distillation on the genotoxic potential of Solvent Refined Coal (SRC-II) liquids. SRC-II source materials and distilled liquids were provided by Pittsburg and Midway Coal Mining Co. Fractional distillations were conducted on products from the P-99 process development unit operating under conditions approximating those anticipated at the SRC-II demonstration facility. Distillation cuts were subjected to chemical fractionation, in vitro bioassay and initial chemical analysis. Findings are discussed as they relate to the temperature at which various distillate cuts were produced. This document is the first of two status reports scheduled for 1981 describing these studies.

  12. ACToR Chemical Structure processing using Open Source ChemInformatics Libraries (FutureToxII)

    Science.gov (United States)

    ACToR (Aggregated Computational Toxicology Resource) is a centralized database repository developed by the National Center for Computational Toxicology (NCCT) at the U.S. Environmental Protection Agency (EPA). Free and open source tools were used to compile toxicity data from ove...

  13. Newton's second law, radiation reaction and type II Einstein-Maxwell fields

    International Nuclear Information System (INIS)

    Newman, Ezra T

    2011-01-01

    Considering perturbations of the Reissner-Nordstroem metric while keeping the perturbations in the class of type II Einstein-Maxwell metrics, we perform a spherical harmonic expansion of all the variables up to the quadrupole term. This leads to rather surprising results. Referring to the source of the metric as a type II particle (analogous to referring to a Schwarzschild-Reissner-Nordstroem or Kerr-Newman particle), we see immediately that the Bondi momentum of the particle takes the classical form of mass times velocity plus an electromagnetic radiation reaction term, while the Bondi mass loss equation becomes the classical gravitational and electromagnetic (electric and magnetic) dipole and quadrupole radiation. The Bondi momentum loss equation turns into Newton's second law of motion containing the Abraham-Lorentz-Dirac radiation reaction force plus a momentum recoil (rocket) force, while the reality condition on the Bondi mass aspect yields the conservation of angular momentum. Two things must be pointed out: (1) these results, (equations of motion, etc) take place, not in the spacetime of the type II metric but in an auxiliary space referred to as H-space, whose physical meaning is rather obscure and (2) this analysis of the type II field equations is a very special case of a similar analysis of the general asymptotically flat Einstein-Maxwell equations. Although the final results are similar (though not the same), the analysis uses different equations (specifically, the type II field equations) and is vastly simpler than the general case. Without a great deal of the technical structures needed in the general case, one can see rather easily where the basic results reside in the type II field equations. (paper)

  14. Cd(II and Pb(II complexes of the polyether ionophorous antibiotic salinomycin

    Directory of Open Access Journals (Sweden)

    Tanabe Makoto

    2011-09-01

    Full Text Available Abstract Background The natural polyether ionophorous antibiotics are used for the treatment of coccidiosis in poultry and ruminants. They are effective agents against infections caused by Gram-positive microorganisms. On the other hand, it was found that some of these compounds selectively bind lead(II ions in in vivo experiments, despite so far no Pb(II-containing compounds of defined composition have been isolated and characterized. To assess the potential of polyether ionophores as possible antidotes in the agriculture, a detailed study on their in vitro complexation with toxic metal ions is required. In the present paper we report for the first time the preparation and the structure elucidation of salinomycin complexes with ions of cadmium(II and lead(II. Results New metal(II complexes of the polyether ionophorous antibiotic salinomycin with Cd(II and Pb(II ions were prepared and structurally characterized by IR, FAB-MS and NMR techniques. The spectroscopic information and elemental analysis data reveal that sodium salinomycin (SalNa undergoes a reaction with heavy metal(II ions to form [Cd(Sal2(H2O2] (1 and [Pb(Sal(NO3] (2, respectively. Abstraction of sodium ions from the cavity of the antibiotic is occurring during the complexation reaction. Salinomycin coordinates with cadmium(II ions as a bidentate monoanionic ligand through the deprotonated carboxylic moiety and one of the hydroxyl groups to yield 1. Two salinomycin anions occupy the equatorial plane of the Cd(II center, while two water molecules take the axial positions of the inner coordination sphere of the metal(II cation. Complex 2 consists of monoanionic salinomycin acting in polydentate coordination mode in a molar ratio of 1: 1 to the metal ion with one nitrate ion for charge compensation. Conclusion The formation of the salinomycin heavy metal(II complexes indicates a possible antidote activity of the ligand in case of chronic/acute intoxications likely to occur in the stock

  15. Cd(II) and Pb(II) complexes of the polyether ionophorous antibiotic salinomycin

    Science.gov (United States)

    2011-01-01

    Background The natural polyether ionophorous antibiotics are used for the treatment of coccidiosis in poultry and ruminants. They are effective agents against infections caused by Gram-positive microorganisms. On the other hand, it was found that some of these compounds selectively bind lead(II) ions in in vivo experiments, despite so far no Pb(II)-containing compounds of defined composition have been isolated and characterized. To assess the potential of polyether ionophores as possible antidotes in the agriculture, a detailed study on their in vitro complexation with toxic metal ions is required. In the present paper we report for the first time the preparation and the structure elucidation of salinomycin complexes with ions of cadmium(II) and lead(II). Results New metal(II) complexes of the polyether ionophorous antibiotic salinomycin with Cd(II) and Pb(II) ions were prepared and structurally characterized by IR, FAB-MS and NMR techniques. The spectroscopic information and elemental analysis data reveal that sodium salinomycin (SalNa) undergoes a reaction with heavy metal(II) ions to form [Cd(Sal)2(H2O)2] (1) and [Pb(Sal)(NO3)] (2), respectively. Abstraction of sodium ions from the cavity of the antibiotic is occurring during the complexation reaction. Salinomycin coordinates with cadmium(II) ions as a bidentate monoanionic ligand through the deprotonated carboxylic moiety and one of the hydroxyl groups to yield 1. Two salinomycin anions occupy the equatorial plane of the Cd(II) center, while two water molecules take the axial positions of the inner coordination sphere of the metal(II) cation. Complex 2 consists of monoanionic salinomycin acting in polydentate coordination mode in a molar ratio of 1: 1 to the metal ion with one nitrate ion for charge compensation. Conclusion The formation of the salinomycin heavy metal(II) complexes indicates a possible antidote activity of the ligand in case of chronic/acute intoxications likely to occur in the stock farming

  16. Synthesis and characterization of zinc(II), cadmium(II) and mercury(II) complexes with bis(bidentate) Schiff bases

    International Nuclear Information System (INIS)

    Das, Mrinal Kanti; Ghosh, Shyamali

    1998-01-01

    A few Zn(II), Cd(II) and Hg(II) complexes of the bis(bidentate) Schiff bases derived from p-phenylenediamine and salicylaldehyde (H 2 Salpphen), and o-phenylenediamine and o-vanillin (H 2 Vanophen), of the type MCl 2 .H 2 L(H 2 L = H 2 Salpphen or H 2 Vanophen) have been synthesised. The complexes have been characterized by elemental analysis, infrared, 1 H and 13 C NMR and mass spectra. (author)

  17. Synthesis, characterization and biological studies of 2-(4-nitro phenylaminocarbonyl)benzoic acid and its complexes with Cr(III), Co(II), Ni(II), Cu(II) and Zn(II)

    International Nuclear Information System (INIS)

    Aqeel Ashraf, M.; Jamil Maah, M.; Yusuf, I.

    2012-01-01

    Cr(III), Co(II), Ni(II), Cu(II) and Zn(II) salts of 2-(4-nitro phenylaminocarbonyl)benzoic acid were characterized by physical, analytical and spectroscopic studies and checked for their in-vitro antimicrobial activity against three bacterial strains, Mycobacterium smegmatis (Gram +ve), Escherichia coli (Gram -ve), Pseudomonas aeuroginosa (Gram -ve) and three fungal strains, Nigrospora oryzae, Aspergillus niger and Candida albicans. The antimicrobial activities of the metal complexes - were found to be greater than those of 2-(4-nitro phenylaminocarbonyl)benzoic acid alone.

  18. Adsorption of aqueous Zn(II) species on synthetic zeolites

    International Nuclear Information System (INIS)

    Badillo-Almaraz, Veronica; Trocellier, Patrick; Davila-Rangel, Ignacio

    2003-01-01

    To supply a good quality drinkable water tends to become a strategic task in both developed and under development countries in the world due to the number of potential contamination sources. One of the major problems is derived from the presence of heavy toxic metals like zinc or lead resulting from industrial activities. Zeolites are known as very efficient mineral substrates for fixing aqueous ionic species through their wide range of channels present in the crystalline structure and due to their strong surface reactivity. MicroPIXE coupled with microRBS (3.05 MeV 4 He + ions) have been used to quantify the incorporation of zinc within two commercial zeolites containing alkali elements (zeolite X and clinoptilolite) in the concentration range of: 0.0002-0.05 M at neutral pH. At the beginning of the interaction between zeolite and Zn(II) solution, the adsorption process exhibits a direct proportionality between the content of zinc fixed on the mineral substrate and the aqueous concentration up to 0.01 M. Beyond this point a saturation effect seems to occur, indicating the strong decrease of available adsorption sites. Sodium or potassium ions are probably exchanged with Zn(II) ions during this process. The compared behaviour of the two zeolites is then discussed in terms of kinetic effects based on ionic radius values. A co-adsorption test carried on with a 50-50% Zn(II) 0.001 M-Pb(II) 0.001 M solution shows that lead does not occupy the same sites as zinc because the content of zinc fixed on the zeolite sample exactly corresponds to the result obtained with a pure 0.001 M Zn(II) solution. All these data clearly showed that zeolite surface reactivity is greatly influenced by the mineral cage-like structure and particularly the presence of pockets, spaces and channels

  19. THE Fe II EMISSION IN ACTIVE GALACTIC NUCLEI: EXCITATION MECHANISMS AND LOCATION OF THE EMITTING REGION

    International Nuclear Information System (INIS)

    Marinello, M.; Rodríguez-Ardila, A.; Garcia-Rissmann, A.; Sigut, T. A. A.; Pradhan, A. K.

    2016-01-01

    We present a study of Fe ii emission in the near-infrared region (NIR) for 25 active galactic nuclei (AGNs) to obtain information about the excitation mechanisms that power it and the location where it is formed. We employ an NIR Fe ii template derived in the literature and find that it successfully reproduces the observed Fe ii spectrum. The Fe ii bump at 9200 Å detected in all objects studied confirms that Lyα fluorescence is always present in AGNs. The correlation found between the flux of the 9200 Å bump, the 1 μm lines, and the optical Fe ii implies that Lyα fluorescence plays an important role in Fe ii production. We determined that at least 18% of the optical Fe ii is due to this process, while collisional excitation dominates the production of the observed Fe ii. The line profiles of Fe ii λ10502, O i λ11287, Ca ii λ8664, and Paβ were compared to gather information about the most likely location where they are emitted. We found that Fe ii, O i and Ca ii have similar widths and are, on average, 30% narrower than Paβ. Assuming that the clouds emitting the lines are virialized, we show that the Fe ii is emitted in a region twice as far from the central source than Paβ. The distance, though, strongly varies: from 8.5 light-days for NGC 4051 to 198.2 light-days for Mrk 509. Our results reinforce the importance of the Fe ii in the NIR to constrain critical parameters that drive its physics and the underlying AGN kinematics, as well as more accurate models aimed at reproducing this complex emission

  20. THE Fe II EMISSION IN ACTIVE GALACTIC NUCLEI: EXCITATION MECHANISMS AND LOCATION OF THE EMITTING REGION

    Energy Technology Data Exchange (ETDEWEB)

    Marinello, M. [Universidade Federal de Itajubá, Rua Doutor Pereira Cabral 1303, 37500-903, Itajubá, MG (Brazil); Rodríguez-Ardila, A.; Garcia-Rissmann, A. [Laboratório Nacional de Astrofísica, Rua Estados Unidos 154, Itajubá, MG, 37504-364 (Brazil); Sigut, T. A. A. [The University of Western Ontario, London, ON N6A 3K7 (Canada); Pradhan, A. K., E-mail: murilo.marinello@gmail.com [McPherson Laboratory, The Ohio State University, 140 W. 18th Ave., Columbus, OH 43210-1173 (United States)

    2016-04-01

    We present a study of Fe ii emission in the near-infrared region (NIR) for 25 active galactic nuclei (AGNs) to obtain information about the excitation mechanisms that power it and the location where it is formed. We employ an NIR Fe ii template derived in the literature and find that it successfully reproduces the observed Fe ii spectrum. The Fe ii bump at 9200 Å detected in all objects studied confirms that Lyα fluorescence is always present in AGNs. The correlation found between the flux of the 9200 Å bump, the 1 μm lines, and the optical Fe ii implies that Lyα fluorescence plays an important role in Fe ii production. We determined that at least 18% of the optical Fe ii is due to this process, while collisional excitation dominates the production of the observed Fe ii. The line profiles of Fe ii λ10502, O i λ11287, Ca ii λ8664, and Paβ were compared to gather information about the most likely location where they are emitted. We found that Fe ii, O i and Ca ii have similar widths and are, on average, 30% narrower than Paβ. Assuming that the clouds emitting the lines are virialized, we show that the Fe ii is emitted in a region twice as far from the central source than Paβ. The distance, though, strongly varies: from 8.5 light-days for NGC 4051 to 198.2 light-days for Mrk 509. Our results reinforce the importance of the Fe ii in the NIR to constrain critical parameters that drive its physics and the underlying AGN kinematics, as well as more accurate models aimed at reproducing this complex emission.