WorldWideScience

Sample records for source width asw

  1. The effect of interaural-time-difference fluctuations on apparent source width

    DEFF Research Database (Denmark)

    Käsbach, Johannes; May, Tobias; Oskarsdottir, Gudrun

    2014-01-01

    For the perception of spaciousness, the temporal fluctuations of the interaural time differences (ITDs) and interaural level differences (ILDs) provide important binaural cues. One major characteristic of spatial perception is apparent source width (ASW), which describes the perceived width of a ...

  2. Assessing the contribution of binaural cues for apparent source width perception via a functional model

    DEFF Research Database (Denmark)

    Käsbach, Johannes; Hahmann, Manuel; May, Tobias

    2016-01-01

    In echoic conditions, sound sources are not perceived as point sources but appear to be expanded. The expansion in the horizontal dimension is referred to as apparent source width (ASW). To elicit this perception, the auditory system has access to fluctuations of binaural cues, the interaural time...... a statistical representation of ITDs and ILDs based on percentiles integrated over time and frequency. The model’s performance was evaluated against psychoacoustic data obtained with noise, speech and music signals in loudspeakerbased experiments. A robust model prediction of ASW was achieved using a cross...

  3. Automating ASW fusion

    OpenAIRE

    Pabelico, James C.

    2011-01-01

    Approved for public release; distribution is unlimited. This thesis examines ASW eFusion, an anti-submarine warfare (ASW) tactical decision aid (TDA) that utilizes Kalman filtering to improve battlespace awareness by simplifying and automating the track management process involved in anti-submarine warfare (ASW) watchstanding operations. While this program can currently help the ASW commander manage uncertainty and make better tactical decisions, the program has several limitations. Comman...

  4. MSPOT a performance optimisation tool for ASW sonar

    NARCIS (Netherlands)

    Beerens, S.P.; Benders, F.P.A.

    2012-01-01

    Several navies are operating or procuring low-frequency active sonar systems (LFAS) as the primary part of their ASW capability. Since LFAS is a relatively new sensor with a performance strongly depending on environmental conditions, the proper operational sensor settings, such as depth and pulse

  5. Silver Cation Coordination Study to AsW9 Ligand – A Trilacunar Arsenotungstate Compound

    Directory of Open Access Journals (Sweden)

    Berta Lavinia

    2017-06-01

    Full Text Available Objective: The main objective of this research is to find the coordination ratio between AsW9 and Ag+, as a preliminary study for synthesizing a new silver-arsenotungstate complex. Material and method: The ligand:cation molar ratio in complexes was determined by conductometric and potentiometric titrations of AsW9 with silver salts: CH3COOAg, AgNO3. Results: The ratio was obtained from the inflexion points of the curves when molar ratio was plotted versus conductivity, or from the equivalence point when silver added volume was plotted versus pH value. Each graphic shows one point of inflexion corresponding to 1:1.54 ratio of AsW9:Ag+. In the same manner, the equivalent volumes determined by graphical method gave the ratio 1:1.53. The spectral results confirmed that a AsW9:Ag+ complex was formed since the ligand absorption maxima values have been changed from 190 nm to 197 nm in the case of using AgNO3 and 196 nm for CH3COOAg corresponding to the W=Od bond, and from 246.5 nm to 274 nm (AgNO3 and 270 nm (CH3COO-Ag+ for the W-Ob,c-W bond. Conclusions: Silver cation exhibit a preference for AsW9 in a ratio of 3 to 2. This ratio can be associated to a sandwich type arrangement, with two trilacunary Keggin building blocks incorporating 3 metal cations in a tetrahedral geometry.

  6. Aspergillus flavus aswA, a gene homolog of Aspergillus nidulans oefC, regulates sclerotial development and biosynthesis of sclerotium-associated secondary metabolites

    Science.gov (United States)

    Aspergillus flavus aswA (AFLA_085170) is a gene encoding a Zn(II)2Cys6 DNA-binding domain. Partial deletion of aswA yielded strains that made a truncated gene transcript and generated a fungus that produced a greatly increased number of sclerotia. These sclerotia were odd-shaped and non-pigmented (w...

  7. Correlation between Angular Widths of CMEs and Characteristics of Their Source Regions

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, X. H.; Feng, X. S. [State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing 100190 (China); Feng, H. Q. [Institute of Space Physics, Luoyang Normal University, Luoyang, Henan 471934 (China); Li, Z. [Institute of Space Weather, Nanjing University of Information Science and Technology, Nanjing, Jiangsu 210044 (China)

    2017-11-10

    The angular width of a coronal mass ejection (CME) is an important factor in determining whether the corresponding interplanetary CME (ICME) and its preceding shock will reach Earth. However, there have been very few studies of the decisive factors of the CME’s angular width. In this study, we use the three-dimensional (3D) angular width of CMEs obtained from the Graduated Cylindrical Shell model based on observations of Solar Terrestrial Relations Observatory ( STEREO ) to study the relations between the CME’s 3D width and characteristics of the CME’s source region. We find that for the CMEs produced by active regions (ARs), the CME width has some correlations with the AR’s area and flux, but these correlations are not strong. The magnetic flux contained in the CME seems to come from only part of the AR’s total flux. For the CMEs produced by flare regions, the correlations between the CME angular width and the flare region’s area and flux are strong. The magnetic flux within those CMEs seems to come from the whole flare region or even from a larger region than the flare. Our findings show that the CME’s 3D angular width can be generally estimated based on observations of Solar Dynamics Observatory for the CME’s source region instead of the observations from coronagraphs on board the Solar and Heliospheric Observatory and STEREO if the two foot points of the CME stay in the same places with no expansion of the CME in the transverse direction until reaching Earth.

  8. Space Vector Pulse Width Modulation Strategy for Single-Phase Three-Level CIC T-source Inverter

    DEFF Research Database (Denmark)

    Shults, Tatiana E.; Husev, Oleksandr O.; Blaabjerg, Frede

    2016-01-01

    This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance of the inver......This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance...... of the inverter, the strategy was compared the traditional pulse-width modulation. It is shown that the approach proposed has fewer switching states and does not suffer from neutral point misbalance....

  9. United States Coast Guard Antisubmarine Warfare (ASW) in the Maritime Defense Zone (MDZ) - A Strategic Approach

    Science.gov (United States)

    1989-03-01

    RIC ILE COPY AIR WAR COLLGE REEAC R~pCR UNITED STATES COAST GUARD ANTISUBMARINE WARFARE (ASW) IN THE MARITIME DEFENSE ZONE (MDZ) -A STRATEGIC...going to perform in these MDZs. Those tasks identified so far include: port and coastal physical security & preventive safety, mine warfare

  10. Human engineering design considerations for the use of signal color enhancement in ASW displays

    Energy Technology Data Exchange (ETDEWEB)

    Banks, W.W.

    1990-11-01

    The Lawrence Livermore National Laboratory (LLNL) was requested to examine and define man-machine limits as part of the Office of Naval Technology's High Gain Initiative program (HGI). As an initial investigative area, LLNL's Systems and Human Performance effort focused upon color display interfaces and the use of color enhancement techniques to define human and system interface limits in signal detection and discrimination tasks. The knowledgeable and prudent use of color in different types of display is believed to facilitate human visual detection, discrimination and recognition in complex visual tasks. The consideration and understanding of the complex set of interacting variables associated with the prudent use of color is essential to optimize human performance, especially in the ASW community. The designers of advanced display technology and signal processing algorithms may be eventually called upon to present pre-processed information to ASW operators and researchers using the latest color enhancement techniques. These techniques, however, may be limited if one does not understand the complexity and limits of human information processing which reflects the assessed state of knowledge relevant to the use of color in displays. The initial sections of this report discuss various aspects of color presentation and the problems typically encountered, while the last section deals with a specific research proposal required to further our understanding and proper use of color enhancement methods.

  11. Transcriptome of Aspergillus flavus aswA (AFLA_085170) deletion strain related to sclerotial development and production of secondary metabolites

    Science.gov (United States)

    Aspergillus flavus produces many secondary metabolites including aflatoxins. Besides conidia, the fungus uses sclerotia as another type of propagule. We obtained transcriptomes from four growth conditions of the aswA mutant, a strain impaired in sclerotial development and production of sclerotium-sp...

  12. Subjective impression of differences in realism, source width, and orientation between auralizations created from multi-channel anechoic recordings

    DEFF Research Database (Denmark)

    Vigeant, Michelle C.; Wang, Lily M.; Rindel, Jens Holger

    2005-01-01

    in realism and source width. Auralizations were made using three different types of musical instruments: woodwinds (flute), brass (trombone) and strings (violin). Subjects were asked to rate each musical track on a seven-point scale for the degree of realism and source width. An analysis of variance (ANOVA......) was carried out to determine the differences between the number of channels and the effect of instrument. A second test was conducted to assess the degree of difficulty in detecting source orientation (facing the audience or facing the stage wall) depending on the number of channels (one, four or thirteen......) and the amount of absorption in the room. [Work supported by the National Science Foundation.]...

  13. Channel Width Change as a Potential Sediment Source, Minnesota River Basin

    Science.gov (United States)

    Lauer, J. W.; Echterling, C.; Lenhart, C. F.; Rausch, R.; Belmont, P.

    2017-12-01

    Turbidity and suspended sediment are important management considerations along the Minnesota River. The system has experience large and relatively consistent increases in both discharge and channel width over the past century. Here we consider the potential role of channel cross section enlargement as a sediment source. Reach-average channel width was digitized from aerial images dated between 1937 and 2015 along multiple sub-reaches of the Minnesota River and its major tributaries. Many of the sub-reaches include several actively migrating bends. The analysis shows relatively consistent increases in width over time, with average increase rates of 0.4 percent per year. Extrapolation to the river network using a regional relationship for cross-sectional area vs. drainage area indicates that large tributaries and main-stem reaches account for most of the bankfull cross-sectional volume in the basin. Larger tributaries and the main stem thus appear more important for widening related sediment production than small tributaries. On a basin-wide basis, widening could be responsible for a gross supply of more sediment than has been gaged at several main-stem sites, indicating that there may be important sinks for both sand and silt/clay size material distributed throughout the system. Sediment storage is probably largest along the lowest-slope reaches of the main stem. While channel width appears to have adjusted relatively quickly in response to discharge and other hydraulic modifications, net storage of sediment in floodplains probably occurs sufficiently slowly that depth adjustment will lag width adjustment significantly. Detailed analysis of the lower Minnesota River using a river segmenting approach allows for a more detailed assessment of reach-scale processes. Away from channel cutoffs, elongation of the channel at eroding bends is consistent with rates observed on other actively migrating rivers. However, the sinuosity increase has been more than compensated by

  14. Assessing Orchestrated Simulation Through Modeling to Quantify the Benefits of Unmanned-Teaming in a Tactical ASW Scenario

    Science.gov (United States)

    2018-03-01

    be used by the model to create pseudo- random behavior for agents. This process is a critical aspect of the simulation because it allows for the...ORCHESTRATED SIMULATION THROUGH MODELING TO QUANTIFY THE BENEFITS OF UNMANNED–MANNED TEAMING IN A TACTICAL ASW SCENARIO by Preston T. Tilus March...Leave blank) 2. REPORT DATE March 2018 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE ASSESSING ORCHESTRATED SIMULATION

  15. Laser ion source with long pulse width for RHIC-EBIS

    International Nuclear Information System (INIS)

    Kondo, K.; Kanesue, T.; Okamura, M.

    2011-01-01

    The Electron Beam Ion Source (EBIS) at Brookhaven National Laboratory is a new heavy ion-projector for RHIC and NASA Space Radiation Laboratory. Laser Ion Source (LIS) with solenoid can supply many kinds of ion from solid targets and is suitable for long pulse length with low current as ion provider for RHIC-EBIS. In order to understand a plasma behavior for fringe field of solenoid, we measure current, pulse width and total ion charges by a new ion probe. The experimental result indicates that the solenoid confines the laser ablation plasma transversely. Laser ion source needs long pulse length with limited current as primary ion provider for RHIC-EBIS. New ion probe can measure current distribution for the radial positions along z axis. The beam pulse length is not effected by magnetic field strength. However, the currents and charges decay with the distance from the end of solenoid. These results indicate that solenoid field has important role for plasma confinement not longitudinally but transversely and solenoid is able to have long pulse length with sufficient total ion charges. Moreover, the results are useful for a design of the extraction system for RHIC-EBIS.

  16. The width of jets in powerful edge-brightened extragalactic double radio sources

    International Nuclear Information System (INIS)

    Banhatti, D.G.

    1987-01-01

    The widths of primary and secondary jets are derived from a sample of 14 double hotspots in powerful extended extragalactic double radio sources. In the model employed, the primary jet extends from the core to the more compact primary hotspot and the secondary jet emerges from the primary hotspot and dissipates to form the diffuse secondary hotspot. Mean values of hotspot size/jet extent imply that the primary and secondary jets, if free, must be 2 0 and > 27 0 wide, respectively. (author)

  17. Beaming teaching application: recording techniques for spatial xylophone sound rendering

    DEFF Research Database (Denmark)

    Markovic, Milos; Madsen, Esben; Olesen, Søren Krarup

    2012-01-01

    BEAMING is a telepresence research project aiming at providing a multimodal interaction between two or more participants located at distant locations. One of the BEAMING applications allows a distant teacher to give a xylophone playing lecture to the students. Therefore, rendering of the xylophon...... to spatial improvements mainly in terms of the Apparent Source Width (ASW). Rendered examples are subjectively evaluated in listening tests by comparing them with binaural recording....

  18. Interactions of bacteria with diatoms: Influence on natural marine biofilms.

    Digital Repository Service at National Institute of Oceanography (India)

    Khandeparker, L.; DeCosta, P.M.; Anil, A.C.; Sawant, S.S.

    therein). In fact, biofilms are considered a reservoir and source of dissemination for V. cholerae (Shikuma & Hadfield 2010). Nutrient concentrations in the surrounding waters also affect the progression of the biofilm community (Qian et al. 2007... to render diatom monocultures near axenic (Patil & Anil 2005c). The following diluents were used – Aged Sea Water (ASW; unenriched control), ASW+streptomycin (ASW+S), ASW+chloramphenicol (ASW+C), f/2 medium (Guillard and Ryther, 1962) prepared in ASW [f...

  19. Preliminary design of an advanced programmable digital filter network for large passive acoustic ASW systems. [Parallel processor

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, T.; Widdoes, Jr., L. C.; Wood, L.

    1976-09-30

    The design of an extremely high performance programmable digital filter of novel architecture, the LLL Programmable Digital Filter, is described. The digital filter is a high-performance multiprocessor having general purpose applicability and high programmability; it is extremely cost effective either in a uniprocessor or a multiprocessor configuration. The architecture and instruction set of the individual processor was optimized with regard to the multiple processor configuration. The optimal structure of a parallel processing system was determined for addressing the specific Navy application centering on the advanced digital filtering of passive acoustic ASW data of the type obtained from the SOSUS net. 148 figures. (RWR)

  20. Source Array Support for Continuous Monitoring of Fish Population and Behavior by Instantaneous Continental-Shelf-Scale Imaging Using Ocean-Waveguide Acoustics

    National Research Council Canada - National Science Library

    Rynne, Ed; Gillette, David

    2006-01-01

    ...) Multistatic ASW Capability Enhancement Program (MACE) as the source of underwater sounds to support active bi-static sonar capabilities for monitoring fish populations and behaviors during a September/October 2006 sea test off the coast of Maine...

  1. Modeling of dislocation channel width evolution in irradiated metals

    Science.gov (United States)

    Doyle, Peter J.; Benensky, Kelsa M.; Zinkle, Steven J.

    2018-02-01

    Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. Based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopy (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Further, examinations of the effect of the so-called "source-broadening" mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel

  2. Writer identification using directional ink-trace width measurements

    NARCIS (Netherlands)

    Brink, A. A.; Smit, J.; Bulacu, M. L.; Schomaker, L. R. B.

    As suggested by modern paleography, the width of ink traces is a powerful source of information for off-line writer identification, particularly if combined with its direction. Such measurements can be computed using simple, fast and accurate methods based on pixel contours, the combination of which

  3. Correlation of H-mode density barrier width and neutral penetration length

    International Nuclear Information System (INIS)

    Groebner, R.J.

    2002-01-01

    Pedestal studies in DIII-D find a good correlation between the width of the H-mode particle barrier width(ne) and the neutral penetration length. These results are obtained by comparing experimental n e profiles to the predictions of an analytic model for the density profile, obtained from a solution of the particle continuity equations for electrons and deuterium atoms. Initial bench-marking shows that the model is consistent with the fluid neutrals model of the UEDGE code. In its range of validity (edge temperature between 0.02-0.3 keV), the model quantitatively predicts the observed values of width(ne), the observed decrease of width(ne) as the pedestal density n e,ped increases, the observed increase of the gradient of n e with the square of n e,ped , and the observation that L-mode and H-mode profiles with the same n e,ped have very similar widths. In the model, width(ne) depends on the fuelling source and on the plasma transport. Thus, these results provide evidence that the width of the particle barrier depends on both plasma physics and atomic physics. (author)

  4. Does Height to Width Ratio Correlate with Mean Volume in Gastropods?

    Science.gov (United States)

    Barriga, R.; Seixas, G.; Payne, J.

    2012-12-01

    Marine organisms' shell shape and size show important biological information. For example, shape and size can dictate how the organism ranges for food and escapes predation. Due to lack of data and analysis, the evolution of shell size in marine gastropods (snails) remains poorly known. In this study, I attempt to find the relationship between height to width ratio and mean volume. I collected height and width measurements from primary literature sources and calculated volume from these measurements. My results indicate that there was no correlation between height to width ratio and mean volume between 500 to 200 Ma, but there was a correlation between 200 Ma to present where there is a steady increase in both height to width ratio and mean volume. This means that shell shape was not an important factor at the beginning of gastropod evolution but after 200 Ma body size evolution was increasingly driven by the height to width ratio.

  5. Evaluation of various energy windows at different radionuclides for scatter and attenuation correction in nuclear medicine.

    Science.gov (United States)

    Asgari, Afrouz; Ashoor, Mansour; Sohrabpour, Mostafa; Shokrani, Parvaneh; Rezaei, Ali

    2015-05-01

    Improving signal to noise ratio (SNR) and qualified images by the various methods is very important for detecting the abnormalities at the body organs. Scatter and attenuation of photons by the organs lead to errors in radiopharmaceutical estimation as well as degradation of images. The choice of suitable energy window and the radionuclide have a key role in nuclear medicine which appearing the lowest scatter fraction as well as having a nearly constant linear attenuation coefficient as a function of phantom thickness. The energy windows of symmetrical window (SW), asymmetric window (ASW), high window (WH) and low window (WL) using Tc-99m and Sm-153 radionuclide with solid water slab phantom (RW3) and Teflon bone phantoms have been compared, and Matlab software and Monte Carlo N-Particle (MCNP4C) code were modified to simulate these methods and obtaining the amounts of FWHM and full width at tenth maximum (FWTM) using line spread functions (LSFs). The experimental data were obtained from the Orbiter Scintron gamma camera. Based on the results of the simulation as well as experimental work, the performance of WH and ASW display of the results, lowest scatter fraction as well as constant linear attenuation coefficient as a function of phantom thickness. WH and ASW were optimal windows in nuclear medicine imaging for Tc-99m in RW3 phantom and Sm-153 in Teflon bone phantom. Attenuation correction was done for WH and ASW optimal windows and for these radionuclides using filtered back projection algorithm. Results of simulation and experimental show that very good agreement between the set of experimental with simulation as well as theoretical values with simulation data were obtained which was nominally less than 7.07 % for Tc-99m and less than 8.00 % for Sm-153. Corrected counts were not affected by the thickness of scattering material. The Simulated results of Line Spread Function (LSF) for Sm-153 and Tc-99m in phantom based on four windows and TEW method were

  6. Pulse width modulation inverter with battery charger

    Science.gov (United States)

    Slicker, James M.

    1985-01-01

    An inverter is connected between a source of DC power and a three-phase AC induction motor, and a microprocessor-based circuit controls the inverter using pulse width modulation techniques. In the disclosed method of pulse width modulation, both edges of each pulse of a carrier pulse train are equally modulated by a time proportional to sin .theta., where .theta. is the angular displacement of the pulse center at the motor stator frequency from a fixed reference point on the carrier waveform. The carrier waveform frequency is a multiple of the motor stator frequency. The modulated pulse train is then applied to each of the motor phase inputs with respective phase shifts of 120.degree. at the stator frequency. Switching control commands for electronic switches in the inverter are stored in a random access memory (RAM) and the locations of the RAM are successively read out in a cyclic manner, each bit of a given RAM location controlling a respective phase input of the motor. The DC power source preferably comprises rechargeable batteries and all but one of the electronic switches in the inverter can be disabled, the remaining electronic switch being part of a "flyback" DC-DC converter circuit for recharging the battery.

  7. Utility Interfaced Pulse-Width Modulation of Solar Fed Voltage ...

    African Journals Online (AJOL)

    Utility Interfaced Pulse-Width Modulation of Solar Fed Voltage Source Inverter Using Fixed-Band Hysteresis Current Controller Method. ... with the conversion of solar energy into electrical energy; boosting the dc power; inversion of the dc to ac and then synchronization of the inverter output with the utility, and consequently, ...

  8. Modified model of neutron resonance widths distribution. Results of total gamma-widths approximation

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.; Khitrov, V.A.

    2011-01-01

    Functional dependences of probability to observe given Γ n 0 value and algorithms for determination of the most probable magnitudes of the modified model of resonance parameter distributions were used for analysis of the experimental data on the total radiative widths of neutron resonances. As in the case of neutron widths, precise description of the Γ γ spectra requires a superposition of three and more probability distributions for squares of the random normally distributed values with different nonzero average and nonunit dispersion. This result confirms the preliminary conclusion obtained earlier at analysis of Γ n 0 that practically in all 56 tested sets of total gamma widths there are several groups noticeably differing from each other by the structure of their wave functions. In addition, it was determined that radiative widths are much more sensitive than the neutron ones to resonance wave functions structure. Analysis of early obtained neutron reduced widths distribution parameters for 157 resonance sets in the mass region of nuclei 35 ≤ A ≤ 249 was also performed. It was shown that the experimental values of widths can correspond with high probability to superposition of several expected independent distributions with their nonzero mean values and nonunit dispersion

  9. Measured pulse width of sonoluminescence flashes in the form of resonance radiation

    Science.gov (United States)

    Giri, Asis; Arakeri, Vijay H.

    1998-09-01

    Recent studies have shown that the measured flash widths from single and multibubble sonoluminescence are in subnanosecond or even picosecond regime. Here, we provide conclusive evidence for the existence of nanosecond multibubble sonoluminescence. This has become possible by our ability to find a medium from which exclusive sodium D line resonance radiation as a form of sonoluminescence is possible. The measured flash width of this emission is found to be in the range of tens of nanoseconds and is sensitively dependent on experimental parameters. Our finding is important since all the earlier pulse width measurements have been limited to emission with the physical source or species responsible for observed optical radiation not being clearly identified. We propose that the presently observed resonance radiation is from ``soft'' bubble collapse as analyzed by V. Kamath et al. [J. Acoust. Soc. Am. 94, 248 (1993)].

  10. Breast Cancer Symptom Clusters Derived from Social Media and Research Study Data Using Improved K-Medoid Clustering

    Science.gov (United States)

    Ping, Qing; Yang, Christopher C.; Marshall, Sarah A.; Avis, Nancy E.; Ip, Edward H.

    2017-01-01

    Most cancer patients, including patients with breast cancer, experience multiple symptoms simultaneously while receiving active treatment. Some symptoms tend to occur together and may be related, such as hot flashes and night sweats. Co-occurring symptoms may have a multiplicative effect on patients’ functioning, mental health, and quality of life. Symptom clusters in the context of oncology were originally described as groups of three or more related symptoms. Some authors have suggested symptom clusters may have practical applications, such as the formulation of more effective therapeutic interventions that address the combined effects of symptoms rather than treating each symptom separately. Most studies that have sought to identify clusters in breast cancer survivors have relied on traditional research studies. Social media, such as online health-related forums, contain a bevy of user-generated content in the form of threads and posts, and could be used as a data source to identify and characterize symptom clusters among cancer patients. The present study seeks to determine patterns of symptom clusters in breast cancer survivors derived from both social media and research study data using improved K-Medoid clustering. A total of 50,426 publicly available messages were collected from Medhelp.com and 653 questionnaires were collected as part of a research study. The network of symptoms built from social media was sparse compared to that of the research study data, making the social media data easier to partition. The proposed revised K-Medoid clustering helps to improve the clustering performance by re-assigning some of the negative-ASW (average silhouette width) symptoms to other clusters after initial K-Medoid clustering. This retains an overall non-decreasing ASW and avoids the problem of trapping in local optima. The overall ASW, individual ASW, and improved interpretation of the final clustering solution suggest improvement. The clustering results suggest

  11. Breast Cancer Symptom Clusters Derived from Social Media and Research Study Data Using Improved K-Medoid Clustering.

    Science.gov (United States)

    Ping, Qing; Yang, Christopher C; Marshall, Sarah A; Avis, Nancy E; Ip, Edward H

    2016-06-01

    Most cancer patients, including patients with breast cancer, experience multiple symptoms simultaneously while receiving active treatment. Some symptoms tend to occur together and may be related, such as hot flashes and night sweats. Co-occurring symptoms may have a multiplicative effect on patients' functioning, mental health, and quality of life. Symptom clusters in the context of oncology were originally described as groups of three or more related symptoms. Some authors have suggested symptom clusters may have practical applications, such as the formulation of more effective therapeutic interventions that address the combined effects of symptoms rather than treating each symptom separately. Most studies that have sought to identify clusters in breast cancer survivors have relied on traditional research studies. Social media, such as online health-related forums, contain a bevy of user-generated content in the form of threads and posts, and could be used as a data source to identify and characterize symptom clusters among cancer patients. The present study seeks to determine patterns of symptom clusters in breast cancer survivors derived from both social media and research study data using improved K-Medoid clustering. A total of 50,426 publicly available messages were collected from Medhelp.com and 653 questionnaires were collected as part of a research study. The network of symptoms built from social media was sparse compared to that of the research study data, making the social media data easier to partition. The proposed revised K-Medoid clustering helps to improve the clustering performance by re-assigning some of the negative-ASW (average silhouette width) symptoms to other clusters after initial K-Medoid clustering. This retains an overall non-decreasing ASW and avoids the problem of trapping in local optima. The overall ASW, individual ASW, and improved interpretation of the final clustering solution suggest improvement. The clustering results suggest

  12. Width and partial widths of unstable particles in the light of the Nielsen identities

    International Nuclear Information System (INIS)

    Grassi, P.A.; Sirlin, A.; Kniehl, B.A.; Hamburg Univ.

    2001-09-01

    Fundamental properties of unstable particles, including mass, width, and partial widths, are examined on the basis of the Nielsen identities (NI) that describe the gauge dependence of Green functions. In particular, we prove that the pole residues and associated definitions of branching ratios and partial widths are gauge independent to all orders. A simpler, previously discussed definition of branching ratios and partial widths is found to be gauge independent through next-to-next-to-leading order. It is then explained how it may be modified in order to extend the gauge independence to all orders. We also show that the physical scattering amplitude is the most general combination of self-energy, vertex, and box contributions that is gauge independent for arbitrary s, discuss the analytical properties of the NI functions, and exhibit explicitly their one-loop expressions in the Z-γ sector of the Standard Model. (orig.)

  13. Width and partial widths of unstable particles in the light of the Nielsen identities

    International Nuclear Information System (INIS)

    Grassi, Pietro A.; Kniehl, Bernd A.; Sirlin, Alberto

    2002-01-01

    Fundamental properties of unstable particles, including mass, width, and partial widths, are examined on the basis of the Nielsen identities (NI) that describe the gauge dependence of Green functions. In particular, we prove that the pole residues and associated definitions of branching ratios and partial widths are gauge independent to all orders. A simpler, previously discussed definition of branching ratios and partial widths is found to be gauge independent through next-to-next-to-leading order. It is then explained how it may be modified in order to extend the gauge independence to all orders. We also show that the physical scattering amplitude is the most general combination of self-energy, vertex, and box contributions that is gauge independent for arbitrary s, discuss the analytical properties of the NI functions, and exhibit explicitly their one-loop expressions in the Z-γ sector of the standard model

  14. GAP WIDTH STUDY IN LASER BUTT-WELDING

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely related......In this paper the maximum allowable gap width in laser butt-welding is intensively studied. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0.5-2.0 m/min, the laser...... to the welding speed, (2) the larger laser power leads to the bigger maximum allowable gap width and (3) the focal point position has very little influence on the maximum gap width....

  15. A deterministic width function model

    Directory of Open Access Journals (Sweden)

    C. E. Puente

    2003-01-01

    Full Text Available Use of a deterministic fractal-multifractal (FM geometric method to model width functions of natural river networks, as derived distributions of simple multifractal measures via fractal interpolating functions, is reported. It is first demonstrated that the FM procedure may be used to simulate natural width functions, preserving their most relevant features like their overall shape and texture and their observed power-law scaling on their power spectra. It is then shown, via two natural river networks (Racoon and Brushy creeks in the United States, that the FM approach may also be used to closely approximate existing width functions.

  16. Research of narrow pulse width, high repetition rate, high output power fiber lasers for deep space exploration

    Science.gov (United States)

    Tang, Yan-feng; Li, Hong-zuo; Wang, Yan; Hao, Zi-qiang; Xiao, Dong-Ya

    2013-08-01

    As human beings expand the research in unknown areas constantly, the deep space exploration has become a hot research topic all over the world. According to the long distance and large amount of information transmission characteristics of deep space exploration, the space laser communication is the preferred mode because it has the advantages of concentrated energy, good security, and large information capacity and interference immunity. In a variety of laser source, fibre-optical pulse laser has become an important communication source in deep space laser communication system because of its small size, light weight and large power. For fiber lasers, to solve the contradiction between the high repetition rate and the peak value power is an important scientific problem. General Q technology is difficult to obtain a shorter pulse widths, This paper presents a DFB semiconductor laser integrated with Electro-absorption modulator to realize the narrow pulse width, high repetition rate of the seed source, and then using a two-cascaded high gain fiber amplifier as amplification mean, to realize the fibre-optical pulse laser with pulse width 3ns, pulse frequency 200kHz and peak power 1kW. According to the space laser atmospheric transmission window, the wavelength selects for 1.06um. It is adopted that full fibre technology to make seed source and amplification, pumping source and amplification of free-space coupled into fiber-coupled way. It can overcome that fibre lasers are vulnerable to changes in external conditions such as vibration, temperature drift and other factors affect, improving long-term stability. The fiber lasers can be modulated by PPM mode, to realize high rate modulation, because of its peak power, high transmission rate, narrow pulse width, high frequency stability, all technical indexes meet the requirements of the exploration of deep space communication technology.

  17. Band width and multiple-angle valence-state mapping of diamond

    International Nuclear Information System (INIS)

    Jimenez, I.; Terminello, L.J.; Sutherland, D.G.J.

    1997-01-01

    The band width may be considered the single most important parameter characterizing the electronic structure of a solid. The ratio of band width and Coulomb repulsion determines how correlated or delocalized an electron system is. Some of the most interesting solids straddle the boundary between localized and delocalized, e.g. the high-temperature superconductors. The bulk of the band calculations available today is based on local density functional (DF) theory. Even though the Kohn-Sham eigenvalues from that theory do not represent the outcome of a band-mapping experiment, they are remarkably similar to the bands mapped via photoemission. Strictly speaking, one should use an excited state calculation that takes the solid's many-body screening response to the hole created in photoemission into account. Diamond is a useful prototype semiconductor because of its low atomic number and large band width, which has made it a long-time favorite for testing band theory. Yet, the two experimental values of the band width of diamond have error bars of ±1 eV and differ by 3.2 eV. To obtain an accurate valence band width for diamond, the authors use a band-mapping method that collects momentum distributions instead of the usual energy distributions. This method has undergone extensive experimental and theoretical tests in determining the band width of lithium fluoride. An efficient, imaging photoelectron spectrometer is coupled with a state-of-the-art undulator beam line at the Advanced Light Source to allow collection of a large number of data sets. Since it takes only a few seconds to take a picture of the photoelectrons emitted into a 84 degrees cone, the authors can use photon energies as high as 350 eV where the cross section for photoemission from the valence band is already quite low, but the emitted photoelectrons behave free-electron-like. This make its much easier to locate the origin of the inter-band transitions in momentum space

  18. Band width and multiple-angle valence-state mapping of diamond

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, I.; Terminello, L.J.; Sutherland, D.G.J. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    The band width may be considered the single most important parameter characterizing the electronic structure of a solid. The ratio of band width and Coulomb repulsion determines how correlated or delocalized an electron system is. Some of the most interesting solids straddle the boundary between localized and delocalized, e.g. the high-temperature superconductors. The bulk of the band calculations available today is based on local density functional (DF) theory. Even though the Kohn-Sham eigenvalues from that theory do not represent the outcome of a band-mapping experiment, they are remarkably similar to the bands mapped via photoemission. Strictly speaking, one should use an excited state calculation that takes the solid`s many-body screening response to the hole created in photoemission into account. Diamond is a useful prototype semiconductor because of its low atomic number and large band width, which has made it a long-time favorite for testing band theory. Yet, the two experimental values of the band width of diamond have error bars of {+-}1 eV and differ by 3.2 eV. To obtain an accurate valence band width for diamond, the authors use a band-mapping method that collects momentum distributions instead of the usual energy distributions. This method has undergone extensive experimental and theoretical tests in determining the band width of lithium fluoride. An efficient, imaging photoelectron spectrometer is coupled with a state-of-the-art undulator beam line at the Advanced Light Source to allow collection of a large number of data sets. Since it takes only a few seconds to take a picture of the photoelectrons emitted into a 84{degrees} cone, the authors can use photon energies as high as 350 eV where the cross section for photoemission from the valence band is already quite low, but the emitted photoelectrons behave free-electron-like. This make its much easier to locate the origin of the inter-band transitions in momentum space.

  19. Rounded leaf end effect of multileaf collimator on penumbra width and radiation field offset: an analytical and numerical study

    International Nuclear Information System (INIS)

    Zhou, Dong; Zhang, Hui; Ye, Peiqing

    2015-01-01

    Penumbra characteristics play a significant role in dose delivery accuracy for radiation therapy. For treatment planning, penumbra width and radiation field offset strongly influence target dose conformity and organ at risk sparing. In this study, we present an analytical and numerical approach for evaluation of the rounded leaf end effect on penumbra characteristics. Based on the rule of half-value layer, algorithms for leaf position calculation and radiation field offset correction were developed, which were advantageous particularly in dealing with large radius leaf end. Computer simulation was performed based on the Monte Carlo codes of EGSnrc/BEAMnrc, with groups of leaf end radii and source sizes. Data processing technique of curve fitting was employed for deriving penumbra width and radiation field offset. Results showed that penumbra width increased with source size. Penumbra width curves for large radius leaf end were U-shaped. This observation was probably related to the fact that radiation beams penetrated through the proximal and distal leaf sides. In contrast, source size had negligible impact on radiation field offset. Radiation field offsets were found to be constant both for analytical method and numerical simulation. However, the overall resulting values of radiation field offset obtained by analytical method were slightly smaller compared with Monte Carlo simulation. The method we proposed could provide insight into the investigation of rounded leaf end effects on penumbra characteristics. Penumbra width and radiation field offset calibration should be carefully performed to commission multileaf collimator for intensity modulated radiotherapy

  20. The effects of lane width, shoulder width, and road cross-sectional reallocation on drivers' behavioral adaptations.

    Science.gov (United States)

    Mecheri, Sami; Rosey, Florence; Lobjois, Régis

    2017-07-01

    Previous research has shown that lane-width reduction makes drivers operate vehicles closer to the center of the road whereas hard-shoulder widening induces a position farther away from the road's center. The goal of the present driving-simulator study was twofold. First, it was aimed at further investigating the respective effects of lane and shoulder width on in-lane positioning strategies, by examining vehicle distance from the center of the lane. The second aim was to assess the impact on safety of three possible cross-sectional reallocations of the width of the road (i.e., three lane-width reductions with concomitant shoulder widening at a fixed cross-sectional width) as compared to a control road. The results confirmed that lane-width reduction made participants drive closer to the road's center. However, in-lane position was affected differently by lane narrowing, depending on the traffic situation. In the absence of oncoming traffic, lane narrowing gave rise to significant shifts in the car's distance from the lane's center toward the edge line, whereas this distance remained similar across lane widths during traffic periods. When the shoulders were at least 0.50m wide, participants drove farther away from both the road center and the lane center. Road reallocation operations resulted in vehicles positioned farther away from the edge of the road and less swerving behavior, without generating higher driving speeds. Finally, it is argued that road-space reallocation may serve as a good low-cost tool for providing a recovery area for steering errors, without impairing drivers' behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Probabilistic Analysis of Crack Width

    Directory of Open Access Journals (Sweden)

    J. Marková

    2000-01-01

    Full Text Available Probabilistic analysis of crack width of a reinforced concrete element is based on the formulas accepted in Eurocode 2 and European Model Code 90. Obtained values of reliability index b seem to be satisfactory for the reinforced concrete slab that fulfils requirements for the crack width specified in Eurocode 2. However, the reliability of the slab seems to be insufficient when the European Model Code 90 is considered; reliability index is less than recommended value 1.5 for serviceability limit states indicated in Eurocode 1. Analysis of sensitivity factors of basic variables enables to find out variables significantly affecting the total crack width.

  2. A de-noising algorithm based on wavelet threshold-exponential adaptive window width-fitting for ground electrical source airborne transient electromagnetic signal

    Science.gov (United States)

    Ji, Yanju; Li, Dongsheng; Yu, Mingmei; Wang, Yuan; Wu, Qiong; Lin, Jun

    2016-05-01

    The ground electrical source airborne transient electromagnetic system (GREATEM) on an unmanned aircraft enjoys considerable prospecting depth, lateral resolution and detection efficiency, etc. In recent years it has become an important technical means of rapid resources exploration. However, GREATEM data are extremely vulnerable to stationary white noise and non-stationary electromagnetic noise (sferics noise, aircraft engine noise and other human electromagnetic noises). These noises will cause degradation of the imaging quality for data interpretation. Based on the characteristics of the GREATEM data and major noises, we propose a de-noising algorithm utilizing wavelet threshold method and exponential adaptive window width-fitting. Firstly, the white noise is filtered in the measured data using the wavelet threshold method. Then, the data are segmented using data window whose step length is even logarithmic intervals. The data polluted by electromagnetic noise are identified within each window based on the discriminating principle of energy detection, and the attenuation characteristics of the data slope are extracted. Eventually, an exponential fitting algorithm is adopted to fit the attenuation curve of each window, and the data polluted by non-stationary electromagnetic noise are replaced with their fitting results. Thus the non-stationary electromagnetic noise can be effectively removed. The proposed algorithm is verified by the synthetic and real GREATEM signals. The results show that in GREATEM signal, stationary white noise and non-stationary electromagnetic noise can be effectively filtered using the wavelet threshold-exponential adaptive window width-fitting algorithm, which enhances the imaging quality.

  3. Determination of core level line widths in XPS of GeS and GeSe

    International Nuclear Information System (INIS)

    Viljoen, P.E.

    1981-01-01

    Measured X-ray photoelectron spectra are broadened owing to several factors. They can be regarded as the sums of the instrument response functions and the finite source widths. By measuring the response function and deconvoluting the measured peak, the form of the measured peak, the instrument function and the deconvoluted line were determined. The former two seem to have a Gauss and the latter a Lorentz form. The X-ray source is known to have a Lorentz form. A simple method, using the shapes of all these lines, is proposed to determine the line width. Applied to GeS and GeSe lines it gives values that agree quite well with other determinations. Strictly speaking, the method is only applicable to our or other similar spectrometers, but it can be generally applied if the line shapes are known or can be determined [af

  4. Stokes line width

    International Nuclear Information System (INIS)

    Nikiskov, A.I.; Ritus, V.I.

    1993-01-01

    The concept of Stokes line width is introduced for the asymptotic expansions of functions near an essential singularity. Explicit expressions are found for functions (switching functions) that switch on the exponentially small terms for the Dawson integral, Airy function, and the gamma function. A different, more natural representation of a function, not associated with expansion in an asymptotic series, in the form of dominant and recessive terms is obtained by a special division of the contour integral which represents the function into contributions of higher and lower saddle points. This division leads to a narrower, natural Stokes line width and a switching function of an argument that depends on the topology of the lines of steepest descent from the saddle point

  5. Masses, widths, and leptonic widths of the higher upsilon resonances

    International Nuclear Information System (INIS)

    Lovelock, D.M.J.; Horstkotte, J.E.; Klopfenstein, C.

    1985-01-01

    The masses, total widths, and leptonic widths of three triplet s-wave bb-bar states UPSILON(4S), UPSILON(5S), and UPSILON(6S) are determined from measurements of the e + e - annihilation cross section into hadrons for 10.55< W<11.25 GeV. The resonances are identified from potential model results and their properties are obtained with the help of a simplified coupled-channels calculation. We find M(4S) = 10.577 GeV, GAMMA(4S) = 25 MeV, GAMMA/sub e/e(4S) = 0.28 keV; M(5S) = 10.845 GeV, GAMMA(5S) = 110 MeV, GAMMA/sub e/e(5S) = 0.37 keV; M(6S) = 11.02 GeV, GAMMA(6S) = 90 MeV, GAMMA/sub e/e(6S) = 0.16 keV

  6. Tree-ring proxies of larch bud moth defoliation: latewood width and blue intensity are more precise than tree-ring width.

    Science.gov (United States)

    Arbellay, Estelle; Jarvis, Ingrid; Chavardès, Raphaël D; Daniels, Lori D; Stoffel, Markus

    2018-05-19

    Reconstructions of defoliation by larch bud moth (LBM, Zeiraphera diniana Gn.) based on European larch (Larix decidua Mill.) tree rings have unraveled outbreak patterns over exceptional temporal and spatial scales. In this study, we conducted tree-ring analyses on 105 increment cores of European larch from the Valais Alps, Switzerland. The well-documented history of LBM outbreaks in Valais provided a solid baseline for evaluating the LBM defoliation signal in multiple tree-ring parameters. First, we used tree-ring width measurements along with regional records of LBM outbreaks to reconstruct the occurrence of these events at two sites within the Swiss Alps. Second, we measured earlywood width, latewood width and blue intensity, and compared these parameters with tree-ring width to assess the capacity of each proxy to detect LBM defoliation. A total of six LBM outbreaks were reconstructed for the two sites between AD 1850 and 2000. Growth suppression induced by LBM was, on average, highest in latewood width (59%), followed by total ring width (54%), earlywood width (51%) and blue intensity (26%). We show that latewood width and blue intensity can improve the temporal accuracy of LBM outbreak reconstructions, as both proxies systematically detected LBM defoliation in the first year it occurred, as well as the differentiation between defoliation and non-defoliation years. This study introduces blue intensity as a promising new proxy of insect defoliation and encourages its use in conjunction with latewood width.

  7. Narrow-width mechanism of a=5 Ξ-state

    International Nuclear Information System (INIS)

    Kumagai-Fuse, I.; Akaishi, Y.

    1995-04-01

    Narrow-width mechanism of ≡ 5 H is discussed by calculating conversion widths to all its possible decay channels. Since the conversion processes have small reaction Q values, the three- and four- body decays are strongly suppressed owing to small phase volumes available. Decay widths to the two-body channels are significantly reduced by the distortion of emitted-particle waves. This mechanism brings about a narrow width of ≡ 5 H. The total width is estimated to be 0.87 MeV, in which the largest contribution comes from the decay into the Λ 4 H * +Λ channel. (author)

  8. Level width broadening effect

    International Nuclear Information System (INIS)

    Zhang Jingshang

    2003-01-01

    In file-6 for double-differential cross sections, the level width broadening effect should be taken into account properly due to Heisenberg' uncertainty. Besides level width broadening effect, the energy resolution in the measurements is also needed in fitting measurement procedure. In general, the traditional normal Gaussian expansion is employed. However, to do so in this way the energy balance could not be held. For this reason, the deformed Gaussian expansion functions with exponential form for both the single energy point and continuous spectrum are introduced, with which the normalization and energy balance conditions could be held exactly in the analytical form. (author)

  9. Design of a variable width pulse generator feasible for manual or automatic control

    Energy Technology Data Exchange (ETDEWEB)

    Vegas, I., E-mail: ignacio.vegas@pas.ucm.es; Antoranz, P.; Miranda, J.M.; Franco, F.J.

    2017-01-01

    A variable width pulse generator featuring more than 4-V peak amplitude and less than 10-ns FWHM is described. In this design the width of the pulses is controlled by means of the control signal slope. Thus, a variable transition time control circuit (TTCC) is also developed, based on the charge and discharge of a capacitor by means of two tunable current sources. Additionally, it is possible to activate/deactivate the pulses when required, therefore allowing the creation of any desired pulse pattern. Furthermore, the implementation presented here can be electronically controlled. In conclusion, due to its versatility, compactness and low cost it can be used in a wide variety of applications.

  10. Dispersive traveling wave solutions of the Equal-Width and Modified Equal-Width equations via mathematical methods and its applications

    Science.gov (United States)

    Lu, Dianchen; Seadawy, Aly R.; Ali, Asghar

    2018-06-01

    The Equal-Width and Modified Equal-Width equations are used as a model in partial differential equations for the simulation of one-dimensional wave transmission in nonlinear media with dispersion processes. In this article we have employed extend simple equation method and the exp(-varphi(ξ)) expansion method to construct the exact traveling wave solutions of equal width and modified equal width equations. The obtained results are novel and have numerous applications in current areas of research in mathematical physics. It is exposed that our method, with the help of symbolic computation, provides a effective and powerful mathematical tool for solving different kind nonlinear wave problems.

  11. Variation of Ring Width and Wood Density in Two Unmanaged Stands of the Mediterranean Oak Quercus faginea

    Directory of Open Access Journals (Sweden)

    Vicelina B. Sousa

    2018-01-01

    Full Text Available Ring width and wood density variation were studied from pith-to-bark and along the stem in two naturally regenerated stands of Quercus faginea Lam. in Portugal. Ring width was significantly different between sites, in both heartwood and sapwood rings, ranging from 1.83 mm to 2.52 mm and from 0.77 mm to 2.11 mm, respectively. Wood density was significantly different between sites only in the heartwood, i.e., 914 kg m−3 and 1037 kg m−3. Site effects were the main source of variation for ring width and wood density within the heartwood as well as for sapwood ring width, while the between-tree effects explained more the density variation within the sapwood. Wood density showed within-tree uniformity that was not affected by site. The stand characteristics such as basal area and tree age may override the environmental growth conditions. There was also a weak correlation between wood density and ring width components therefore suggesting the possibility of forestry management for both fast tree growth and high wood density.

  12. Study on the E-beam pulse width scaling for a 25-kilojoule KrF amplifier

    International Nuclear Information System (INIS)

    Ramirez, J.J.

    1983-02-01

    The KrF laser is being considered as an ICF driver candidate. Since this laser is not an energy storing system, the output energy of an amplifier is delivered over the entire pulse width of the excitation source. E-beam pumping is preferred for large energy systems. The e-beam pulse width is constrained to a few hundred nanoseconds by laser operation and pulsed power considerations. The target requires pulses of a few nanoseconds. Angular multiplexing of probe beams through the amplifier is a preferred scheme for bridging this difference in timing requirements. Progressively shorter target irradiation times may be obtained by using shorter pulse probe beams and by either increasing the number of angular multiplexed beams or by decreasing the e-beam pulse width. This report documents results of a study on the consequences of following the latter approach

  13. Criteria for setting the width of CCD front end transistor to reach minimum pixel noise

    International Nuclear Information System (INIS)

    Fasoli, L.; Sampietro, M.

    1996-01-01

    The paper gives the criteria to calculate the width of the front end transistor integrated next to the charge sensing electrode of CCD's or, in general, of semiconductor detectors, in order to reach the minimum noise in the readout of the signal charge. The paper, for the first time, accounts for white, series and parallel, and 1/f noise contribution. In addition, it points out two different design criteria depending whether a JFET or a MOSFET is used. The attention given to the JFET is due to a lower 1/f noise component, which makes these transistors more and more appealing as input devices in very high resolution detectors. The paper shows that there is a characteristic width of the FET gate that practically doesn't depend on the noise sources but depends only on the capacitance seen by the charge sensing electrode of the detector, making possible the optimum design of the transistor prior to the knowledge of the real values of the spectral density of the noise sources, which are usually precisely known only at the end of the fabrication process. The paper shows that the pixel noise raises sharply as the transistor gate width departs from its optimum value

  14. Tourniquet pressures: strap width and tensioning system widths.

    Science.gov (United States)

    Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M

    2014-01-01

    Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically

  15. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  16. Half-width at half-maximum, full-width at half-maximum analysis

    Indian Academy of Sciences (India)

    addition to the well-defined parameter full-width at half-maximum (FWHM). The distribution of ... optical side-lobes in the diffraction pattern resulting in steep central maxima [6], reduc- tion of effects of ... and broad central peak. The idea of.

  17. A quantitative analysis of transtensional margin width

    Science.gov (United States)

    Jeanniot, Ludovic; Buiter, Susanne J. H.

    2018-06-01

    Continental rifted margins show variations between a few hundred to almost a thousand kilometres in their conjugated widths from the relatively undisturbed continent to the oceanic crust. Analogue and numerical modelling results suggest that the conjugated width of rifted margins may have a relationship to their obliquity of divergence, with narrower margins occurring for higher obliquity. We here test this prediction by analysing the obliquity and rift width for 26 segments of transtensional conjugate rifted margins in the Atlantic and Indian Oceans. We use the plate reconstruction software GPlates (http://www.gplates.org) for different plate rotation models to estimate the direction and magnitude of rifting from the initial phases of continental rifting until breakup. Our rift width corresponds to the distance between the onshore maximum topography and the last identified continental crust. We find a weak positive correlation between the obliquity of rifting and rift width. Highly oblique margins are narrower than orthogonal margins, as expected from analogue and numerical models. We find no relationships between rift obliquities and rift duration nor the presence or absence of Large Igneous Provinces (LIPs).

  18. Lake Basin Fetch and Maximum Length/Width

    Data.gov (United States)

    Minnesota Department of Natural Resources — Linear features representing the Fetch, Maximum Length and Maximum Width of a lake basin. Fetch, maximum length and average width are calcuated from the lake polygon...

  19. Evaluation of width and width uniformity of near-field electrospinning printed micro and sub-micrometer lines based on optical image processing

    Science.gov (United States)

    Zhao, Libo; Xia, Yong; Hebibul, Rahman; Wang, Jiuhong; Zhou, Xiangyang; Hu, Yingjie; Li, Zhikang; Luo, Guoxi; Zhao, Yulong; Jiang, Zhuangde

    2018-03-01

    This paper presents an experimental study using image processing to investigate width and width uniformity of sub-micrometer polyethylene oxide (PEO) lines fabricated by near-filed electrospinning (NFES) technique. An adaptive thresholding method was developed to determine the optimal gray values to accurately extract profiles of printed lines from original optical images. And it was proved with good feasibility. The mechanism of the proposed thresholding method was believed to take advantage of statistic property and get rid of halo induced errors. Triangular method and relative standard deviation (RSD) were introduced to calculate line width and width uniformity, respectively. Based on these image processing methods, the effects of process parameters including substrate speed (v), applied voltage (U), nozzle-to-collector distance (H), and syringe pump flow rate (Q) on width and width uniformity of printed lines were discussed. The research results are helpful to promote the NFES technique for fabricating high resolution micro and sub-micro lines and also helpful to optical image processing at sub-micro level.

  20. Seawater cultivation of freshwater cyanobacterium Synechocystis sp. PCC 6803 drastically alters amino acid composition and glycogen metabolism

    Directory of Open Access Journals (Sweden)

    Hiroko eIijima

    2015-04-01

    Full Text Available Water use assessment is important for bioproduction using cyanobacteria. For eco-friendly reasons, seawater should preferably be used for cyanobacteria cultivation instead of freshwater. In this study, we demonstrated that the freshwater unicellular cyanobacterium Synechocystis sp. PCC 6803 could be grown in a medium based on seawater. The Synechocystis wild-type strain grew well in an artificial seawater (ASW medium supplemented with nitrogen and phosphorus sources. The addition of HEPES buffer improved cell growth overall, although the growth in ASW medium was inferior to that in the synthetic BG-11 medium. The levels of proteins involved in sugar metabolism changed depending on the culture conditions. The biosynthesis of several amino acids including aspartate, glutamine, glycine, proline, ornithine, and lysine, was highly up-regulated by cultivation in ASW. Two types of natural seawater (NSW were also made available for the cultivation of Synechocystis cells, with supplementation of both nitrogen and phosphorus sources. These results revealed the potential use of seawater for the cultivation of freshwater cyanobacteria, which would help to reduce freshwater consumption during biorefinery using cyanobacteria.

  1. Masses, widths and leptonic widths of the higher upsilon resonances

    International Nuclear Information System (INIS)

    Klopfenstein, C.; Lovelock, D.M.J.; Horstkotte, J.E.

    1985-01-01

    The masses, total widths and leptonic widths of three triplet s-wave bb-bar states Υ(4S), Υ(5S) and Υ(6S) are determined by unfolding the cross section features observed in the hadronic cross section in the √s region betweeen 10.55 to 11.25 GeV. Both the identification of the resonances and the deduction of their properties rely on the validity of potential models' description of heavy quarkonium states which lie close (<0.6 GeV) to the open flavor threshold. The authors find M(4S) = 10.5774 +- 0.0008 GeV, Γ(4S) = 23 +- 2.3 MeV, Γ/sub ee/(4S) = 0.28 +- 0.04 keV; M(5S) = 10.845 +- 0.02 GeV, Γ(5S) = 110 +- 15 MeV, Γ/sub ee/(5S) = 0.37 +- 0.06 keV; M(6S) = 11.02 +- 0.03 GeV, Γ(6S) = 90 +- 20 MeV, Γ/sub ee/(6S) = 0.16 +- 0.04 keV. All errors are statistical only

  2. Effects of Lane Width, Lane Position and Edge Shoulder Width on Driving Behavior in Underground Urban Expressways: A Driving Simulator Study

    Directory of Open Access Journals (Sweden)

    Shuo Liu

    2016-10-01

    Full Text Available This study tested the effects of lane width, lane position and edge shoulder width on driving behavior for a three-lane underground urban expressway. A driving simulator was used with 24 volunteer test subjects. Five lane widths (2.85, 3.00, 3.25, 3.50, and 3.75 m and three shoulder widths (0.50, 0.75, and 1.00 m were studied. Driving speed, lane deviation and subjective perception of driving behavior were collected as performance measures. The results show that lane and shoulder width have significant effects on driving speed. Average driving speed increases from 60.01 km/h in the narrowest lane to 88.05 km/h in the widest lane. While both narrower lanes and shoulders result in reduced speed and lateral lane deviation, the effect of lane width is greater than that of shoulder width. When the lane and shoulder are narrow, drivers in the left or right lane tend to shy away from the tunnel wall, even encroaching into the neighboring middle lane. As the lane or shoulder gets wider, drivers tend to stay in the middle of the lane. An interesting finding is that although few participants acknowledged that lane position had any great bearing on their driving behaviors, the observed driving speed is statistically higher in the left lane than in the other two lanes when the lane width is narrow (in 2.85, 3 and 3.25 m lanes. These findings provided support for amending the current design specifications of urban underground roads, such as the relationship between design speed and lane width, speed limit, and combination form of lanes.

  3. Comparison of Arch Width Changes Following Orthodontic ...

    African Journals Online (AJOL)

    2015-11-21

    Nov 21, 2015 ... Materials and Methods: The study was conducted with pre- and post-treatment digital models from ... or posterior arch width following orthodontic treatment ..... premolar extraction cases show significant arch width increases in ...

  4. Beam-width spreading of vortex beams in free space

    Science.gov (United States)

    Wang, Weiwei; Li, Jinhong; Duan, Meiling

    2018-01-01

    Based on the extended Huygens-Fresnel principle and the definition of second-order moments of the Wigner distribution function, the analytical expression for the beam-width spreading of Gaussian Schell-model (GSM) vortex beams in free space are derived, and used to study the influence of beam parameters on the beam-width spreading of GSM vortex beams. With the increment of the propagation distance, the beam-width spreading of GSM vortex beams will increase; the bigger the topological charge, spatial correlation length, wavelength and waist width are, the smaller the beam-width spreading is.

  5. Heuristic Drift-based Model of the Power Scrape-off width in H-mode Tokamaks

    International Nuclear Information System (INIS)

    Goldston, Robert J.

    2011-01-01

    An heuristic model for the plasma scrape-off width in H-mode plasmas is introduced. Grad B and curv B drifts into the SOL are balanced against sonic parallel flows out of the SOL, to the divertor plates. The overall particle flow pattern posited is a modification for open field lines of Pfirsch-Shlueter flows to include sinks to the divertors. These assumptions result in an estimated SOL width of ∼ 2αρ p /R. They also result in a first-principles calculation of the particle confinement time of H-mode plasmas, qualitatively consistent with experimental observations. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, defined above, with heat from the main plasma. The separatrix temperature is calculated based on a two-point model balancing power input to the SOL with Spitzer-Haerm parallel thermal conduction losses to the divertor. This results in a heuristic closed-form prediction for the power scrape-off width that is in reasonable quantitative agreement both in absolute magnitude and in scaling with recent experimental data from deuterium plasmas. Further work should include full numerical calculations, including all magnetic and electric drifts, as well as more thorough comparison with experimental data.

  6. Spherical bodies of constant width

    OpenAIRE

    Lassak, Marek; Musielak, Michał

    2018-01-01

    The intersection $L$ of two different non-opposite hemispheres $G$ and $H$ of a $d$-dimensional sphere $S^d$ is called a lune. By the thickness of $L$ we mean the distance of the centers of the $(d-1)$-dimensional hemispheres bounding $L$. For a hemisphere $G$ supporting a %spherical convex body $C \\subset S^d$ we define ${\\rm width}_G(C)$ as the thickness of the narrowest lune or lunes of the form $G \\cap H$ containing $C$. If ${\\rm width}_G(C) =w$ for every hemisphere $G$ supporting $C$, we...

  7. Stieltjes-moment-theory technique for calculating resonance width's

    International Nuclear Information System (INIS)

    Hazi, A.U.

    1978-12-01

    A recently developed method for calculating the widths of atomic and molecular resonances is reviewed. The method is based on the golden-rule definition of the resonance width, GAMMA(E). The method uses only square-integrable, L 2 , basis functions to describe both the resonant and the non-resonant parts of the scattering wave function. It employs Stieltjes-moment-theory techniques to extract a continuous approximation for the width discrete representation of the background continuum. Its implementation requires only existing atomic and molecular structure codes. Many-electron effects, such as correlation and polarization, are easily incorporated into the calculation of the width via configuration interaction techniques. Once the width, GAMMA(E), has been determined, the energy shift can be computed by a straightforward evaluation of the required principal-value integral. The main disadvantage of the method is that it provides only the total width of a resonance which decays into more than one channel in a multichannel problem. A review of the various aspects of the theory is given first, and then representative results that have been obtained with this method for several atomic and molecular resonances are discussed. 28 references, 3 figures, 4 tables

  8. The decay width of stringy hadrons

    Science.gov (United States)

    Sonnenschein, Jacob; Weissman, Dorin

    2018-02-01

    In this paper we further develop a string model of hadrons by computing their strong decay widths and comparing them to experiment. The main decay mechanism is that of a string splitting into two strings. The corresponding total decay width behaves as Γ = π/2 ATL where T and L are the tension and length of the string and A is a dimensionless universal constant. We show that this result holds for a bosonic string not only in the critical dimension. The partial width of a given decay mode is given by Γi / Γ =Φi exp ⁡ (- 2 πCmsep2 / T) where Φi is a phase space factor, msep is the mass of the "quark" and "antiquark" created at the splitting point, and C is a dimensionless coefficient close to unity. Based on the spectra of hadrons we observe that their (modified) Regge trajectories are characterized by a negative intercept. This implies a repulsive Casimir force that gives the string a "zero point length". We fit the theoretical decay width to experimental data for mesons on the trajectories of ρ, ω, π, η, K*, ϕ, D, and Ds*, and of the baryons N, Δ, Λ, and Σ. We examine both the linearity in L and the exponential suppression factor. The linearity was found to agree with the data well for mesons but less for baryons. The extracted coefficient for mesons A = 0.095 ± 0.015 is indeed quite universal. The exponential suppression was applied to both strong and radiative decays. We discuss the relation with string fragmentation and jet formation. We extract the quark-diquark structure of baryons from their decays. A stringy mechanism for Zweig suppressed decays of quarkonia is proposed and is shown to reproduce the decay width of ϒ states. The dependence of the width on spin and flavor symmetry is discussed. We further apply this model to the decays of glueballs and exotic hadrons.

  9. Step width alters iliotibial band strain during running.

    Science.gov (United States)

    Meardon, Stacey A; Campbell, Samuel; Derrick, Timothy R

    2012-11-01

    This study assessed the effect of step width during running on factors related to iliotibial band (ITB) syndrome. Three-dimensional (3D) kinematics and kinetics were recorded from 15 healthy recreational runners during overground running under various step width conditions (preferred and at least +/- 5% of their leg length). Strain and strain rate were estimated from a musculoskeletal model of the lower extremity. Greater ITB strain and strain rate were found in the narrower step width condition (p running, especially in persons whose running style is characterized by a narrow step width, may be beneficial in the treatment and prevention of running-related ITB syndrome.

  10. Palindromic widths of nilpotent and wreath products

    Indian Academy of Sciences (India)

    Palindromic width; commutator width; wreath products; nilpotent product. 2000 Mathematics ... An algorithm of the computation of the commutator length in free non-abelian .... It is clear that A(1)B = A × B is the direct sum. Let us list some ...

  11. Width lines of non hydrogenoid ions

    International Nuclear Information System (INIS)

    Bertuccelli, D.; Bertuccelli, G.; Di Rocco, H.O.

    1990-01-01

    An extensive theoretical and experimental work was carried out on the ns-np and np-nd line widths (w) of noble gases after ionization (n=n 0 +1, were n 0 is the principal quantum number of the fundamental configuration). A high current 'pinch' discharge was used as source. Electron density and temperature were estimated to be N e =2.65x10 16 cm -3 and T=1.45x10 4 K respectively. Calculations were based on a semi-empirical approximation and the matrix elements (or transition probabilities) were evaluated in different approximation. Comparing our measurements with those of other authors, a systematic tendency, with a dependence on atomic number Z and ionization energy of the higher level L, was established. Finally, it has been established that for N e >10 17 cm -3 , w ∝ N e γ , where γ=5/6. (Author). 8 refs., 1 fig., 1 tab

  12. An Heuristic Drift-Based Model of the Power Scrape-Off Width in H-Mode Tokamaks

    International Nuclear Information System (INIS)

    Goldston, Robert J.

    2011-01-01

    An heuristic model for the plasma scrape-off width in H-mode plasmas is introduced. Grad B and curv B drifts into the SOL are balanced against sonic parallel flows out of the SOL, to the divertor plates. The overall mass flow pattern posited is a modification for open field lines of Pfirsch-Shlueter flows to include sinks to the divertors. These assumptions result in an estimated SOL width of 2αρ p /R. They also result in a first-principles calculation of the particle confinement time of H-mode plasmas, qualitatively consistent with experimental observations. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, defined above, with heat from the main plasma. The separatrix temperature is calculated based on a two-point model balancing power input to the SOL with Spitzer-Haerm parallel thermal conduction losses to the divertor. This results in an heuristic closed-form prediction for the power scrape-off width that is in remarkable quantitative agreement both in absolute magnitude and in scaling with recent experimental data. Further work should include full numerical calculations, including all magnetic and electric drifts, as well as more thorough comparison with experimental data.

  13. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    , resulting in the natural balance of input current. For maintaining the normalized volt-sec average unchanged, the alternative phase opposition disposition (APOD) modulation scheme with typical gating signal mapping technique from voltage source inverter (VSI) to CSI can be assumed to control the five......This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches......-level buck-boost CSIs. Next by observing the hidden current charging path during inductive charging interval under APOD modulation, it is noted that the buck-boost five-level CSI can then be further modified with lesser active component without degrading output performance. To verify the theoretical findings...

  14. Global synchronization of parallel processors using clock pulse width modulation

    Science.gov (United States)

    Chen, Dong; Ellavsky, Matthew R.; Franke, Ross L.; Gara, Alan; Gooding, Thomas M.; Haring, Rudolf A.; Jeanson, Mark J.; Kopcsay, Gerard V.; Liebsch, Thomas A.; Littrell, Daniel; Ohmacht, Martin; Reed, Don D.; Schenck, Brandon E.; Swetz, Richard A.

    2013-04-02

    A circuit generates a global clock signal with a pulse width modification to synchronize processors in a parallel computing system. The circuit may include a hardware module and a clock splitter. The hardware module may generate a clock signal and performs a pulse width modification on the clock signal. The pulse width modification changes a pulse width within a clock period in the clock signal. The clock splitter may distribute the pulse width modified clock signal to a plurality of processors in the parallel computing system.

  15. Nightside studies of coherent HF Radar spectral width behaviour

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    2002-09-01

    Full Text Available A previous case study found a relationship between high spectral width measured by the CUTLASS Finland HF radar and elevated electron temperatures observed by the EISCAT and ESR incoherent scatter radars in the post-midnight sector of magnetic local time. This paper expands that work by briefly re-examining that interval and looking in depth at two further case studies. In all three cases a region of high HF spectral width (>200 ms-1 exists poleward of a region of low HF spectral width (<200 ms-1. Each case, however, occurs under quite different geomagnetic conditions. The original case study occurred during an interval with no observed electrojet activity, the second study during a transition from quiet to active conditions with a clear band of ion frictional heating indicating the location of the flow reversal boundary, and the third during an isolated sub-storm. These case studies indicate that the relationship between elevated electron temperature and high HF radar spectral width appears on closed field lines after 03:00 magnetic local time (MLT on the nightside. It is not clear whether the same relationship would hold on open field lines, since our analysis of this relationship is restricted in latitude. We find two important properties of high spectral width data on the nightside. Firstly the high spectral width values occur on both open and closed field lines, and secondly that the power spectra which exhibit high widths are both single-peak and multiple-peak. In general the regions of high spectral width (>200 ms-1 have more multiple-peak spectra than the regions of low spectral widths whilst still maintaining a majority of single-peak spectra. We also find that the region of ion frictional heating is collocated with many multiple-peak HF spectra. Several mechanisms for the generation of high spectral width have been proposed which would produce multiple-peak spectra, these are discussed in relation to the data presented here. Since the

  16. Nightside studies of coherent HF Radar spectral width behaviour

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    Full Text Available A previous case study found a relationship between high spectral width measured by the CUTLASS Finland HF radar and elevated electron temperatures observed by the EISCAT and ESR incoherent scatter radars in the post-midnight sector of magnetic local time. This paper expands that work by briefly re-examining that interval and looking in depth at two further case studies. In all three cases a region of high HF spectral width (>200 ms-1 exists poleward of a region of low HF spectral width (<200 ms-1. Each case, however, occurs under quite different geomagnetic conditions. The original case study occurred during an interval with no observed electrojet activity, the second study during a transition from quiet to active conditions with a clear band of ion frictional heating indicating the location of the flow reversal boundary, and the third during an isolated sub-storm. These case studies indicate that the relationship between elevated electron temperature and high HF radar spectral width appears on closed field lines after 03:00 magnetic local time (MLT on the nightside. It is not clear whether the same relationship would hold on open field lines, since our analysis of this relationship is restricted in latitude. We find two important properties of high spectral width data on the nightside. Firstly the high spectral width values occur on both open and closed field lines, and secondly that the power spectra which exhibit high widths are both single-peak and multiple-peak. In general the regions of high spectral width (>200 ms-1 have more multiple-peak spectra than the regions of low spectral widths whilst still maintaining a majority of single-peak spectra. We also find that the region of ion frictional heating is collocated with many multiple-peak HF spectra. Several mechanisms for the generation of high spectral width have been proposed which would produce multiple-peak spectra, these are discussed in relation to

  17. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Arnsfelt

    2006-01-01

    We obtain a characterization of ACC0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  18. Measured, calculated and predicted Stark widths of the singly ionized C, N, O, F, Ne, Si, P, S, Cl and Ar spectral lines

    Directory of Open Access Journals (Sweden)

    Djeniže S.

    2000-01-01

    Full Text Available In order to find reliable Stark width data, needed in plasma spectroscopy comparision between the existing measured, calculated and predicted Stark width values was performed for ten singly ionized emitters: C, N, O, F, Ne Si, P, S, Cl and Ar in the lower lying 3s - 3p, 3p - 3d and 4s - 4p transitions. These emitters are present in many cosmic light sources. On the basis of the agreement between mentioned values 17 spectral lines from six singly ionized spectra have been recommended, for the first time, for plasma spectroscopy as spectral lines with reliable Stark width data. Critical analysis of the existing Stark width data is also given.

  19. Line Width Recovery after Vectorization of Engineering Drawings

    Directory of Open Access Journals (Sweden)

    Gramblička Matúš

    2016-12-01

    Full Text Available Vectorization is the conversion process of a raster image representation into a vector representation. The contemporary commercial vectorization software applications do not provide sufficiently high quality outputs for such images as do mechanical engineering drawings. Line width preservation is one of the problems. There are applications which need to know the line width after vectorization because this line attribute carries the important semantic information for the next 3D model generation. This article describes the algorithm that is able to recover line width of individual lines in the vectorized engineering drawings. Two approaches are proposed, one examines the line width at three points, whereas the second uses a variable number of points depending on the line length. The algorithm is tested on real mechanical engineering drawings.

  20. Characterizing graphs of maximum matching width at most 2

    DEFF Research Database (Denmark)

    Jeong, Jisu; Ok, Seongmin; Suh, Geewon

    2017-01-01

    The maximum matching width is a width-parameter that is de ned on a branch-decomposition over the vertex set of a graph. The size of a maximum matching in the bipartite graph is used as a cut-function. In this paper, we characterize the graphs of maximum matching width at most 2 using the minor o...

  1. Effect of step width manipulation on tibial stress during running.

    Science.gov (United States)

    Meardon, Stacey A; Derrick, Timothy R

    2014-08-22

    Narrow step width has been linked to variables associated with tibial stress fracture. The purpose of this study was to evaluate the effect of step width on bone stresses using a standardized model of the tibia. 15 runners ran at their preferred 5k running velocity in three running conditions, preferred step width (PSW) and PSW±5% of leg length. 10 successful trials of force and 3-D motion data were collected. A combination of inverse dynamics, musculoskeletal modeling and beam theory was used to estimate stresses applied to the tibia using subject-specific anthropometrics and motion data. The tibia was modeled as a hollow ellipse. Multivariate analysis revealed that tibial stresses at the distal 1/3 of the tibia differed with step width manipulation (p=0.002). Compression on the posterior and medial aspect of the tibia was inversely related to step width such that as step width increased, compression on the surface of tibia decreased (linear trend p=0.036 and 0.003). Similarly, tension on the anterior surface of the tibia decreased as step width increased (linear trend p=0.029). Widening step width linearly reduced shear stress at all 4 sites (pstresses experienced by the tibia during running were influenced by step width when using a standardized model of the tibia. Wider step widths were generally associated with reduced loading of the tibia and may benefit runners at risk of or experiencing stress injury at the tibia, especially if they present with a crossover running style. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Analytical estimation of emission zone mean position and width in organic light-emitting diodes from emission pattern image-source interference fringes

    International Nuclear Information System (INIS)

    Epstein, Ariel; Tessler, Nir; Einziger, Pinchas D.; Roberts, Matthew

    2014-01-01

    We present an analytical method for evaluating the first and second moments of the effective exciton spatial distribution in organic light-emitting diodes (OLED) from measured emission patterns. Specifically, the suggested algorithm estimates the emission zone mean position and width, respectively, from two distinct features of the pattern produced by interference between the emission sources and their images (induced by the reflective cathode): the angles in which interference extrema are observed, and the prominence of interference fringes. The relations between these parameters are derived rigorously for a general OLED structure, indicating that extrema angles are related to the mean position of the radiating excitons via Bragg's condition, and the spatial broadening is related to the attenuation of the image-source interference prominence due to an averaging effect. The method is applied successfully both on simulated emission patterns and on experimental data, exhibiting a very good agreement with the results obtained by numerical techniques. We investigate the method performance in detail, showing that it is capable of producing accurate estimations for a wide range of source-cathode separation distances, provided that the measured spectral interval is large enough; guidelines for achieving reliable evaluations are deduced from these results as well. As opposed to numerical fitting tools employed to perform similar tasks to date, our approximate method explicitly utilizes physical intuition and requires far less computational effort (no fitting is involved). Hence, applications that do not require highly resolved estimations, e.g., preliminary design and production-line verification, can benefit substantially from the analytical algorithm, when applicable. This introduces a novel set of efficient tools for OLED engineering, highly important in the view of the crucial role the exciton distribution plays in determining the device performance.

  3. Analytical estimation of emission zone mean position and width in organic light-emitting diodes from emission pattern image-source interference fringes

    Energy Technology Data Exchange (ETDEWEB)

    Epstein, Ariel, E-mail: ariel.epstein@utoronto.ca; Tessler, Nir, E-mail: nir@ee.technion.ac.il; Einziger, Pinchas D. [Department of Electrical Engineering, Technion-Israel Institute of Technology, Haifa 32000 (Israel); Roberts, Matthew, E-mail: mroberts@cdtltd.co.uk [Cambridge Display Technology Ltd, Building 2020, Cambourne Business Park, Cambourne, Cambridgeshire CB23 6DW (United Kingdom)

    2014-06-14

    We present an analytical method for evaluating the first and second moments of the effective exciton spatial distribution in organic light-emitting diodes (OLED) from measured emission patterns. Specifically, the suggested algorithm estimates the emission zone mean position and width, respectively, from two distinct features of the pattern produced by interference between the emission sources and their images (induced by the reflective cathode): the angles in which interference extrema are observed, and the prominence of interference fringes. The relations between these parameters are derived rigorously for a general OLED structure, indicating that extrema angles are related to the mean position of the radiating excitons via Bragg's condition, and the spatial broadening is related to the attenuation of the image-source interference prominence due to an averaging effect. The method is applied successfully both on simulated emission patterns and on experimental data, exhibiting a very good agreement with the results obtained by numerical techniques. We investigate the method performance in detail, showing that it is capable of producing accurate estimations for a wide range of source-cathode separation distances, provided that the measured spectral interval is large enough; guidelines for achieving reliable evaluations are deduced from these results as well. As opposed to numerical fitting tools employed to perform similar tasks to date, our approximate method explicitly utilizes physical intuition and requires far less computational effort (no fitting is involved). Hence, applications that do not require highly resolved estimations, e.g., preliminary design and production-line verification, can benefit substantially from the analytical algorithm, when applicable. This introduces a novel set of efficient tools for OLED engineering, highly important in the view of the crucial role the exciton distribution plays in determining the device performance.

  4. The significance of biometric parameters in determining anterior teeth width

    Directory of Open Access Journals (Sweden)

    Strajnić Ljiljana

    2013-01-01

    Full Text Available Background/Aim. An important element of prosthetic treatment of edentulous patients is selecting the size of anterior artificial teeth that will restore the natural harmony of one’s dentolabial structure as well as the whole face. The main objective of this study was to determine the correlation between the inner canthal distance (ICD and interalar width (IAW on one side and the width of both central incisors (CIW, the width of central and lateral incisors (CLIW, the width of anterior teeth (ATW, the width between the canine cusps (CCW, which may be useful in clinical practice. Methods. A total of 89 subjects comprising 23 male and 66 female were studied. Their age ranged from 19 to 34 years with the mean of 25 years. Only the subjects with the preserved natural dentition were included in the sample. All facial and intraoral tooth measurements were made with a Boley Gauge (Buffalo Dental Manufacturing Co., Brooklyn NY, USA having a resolution of 0.1mm. Results. A moderate correlation was established between the interalar width and combined width of anterior teeth and canine cusp width (r = 0.439, r = 0.374. A low correlation was established between the inner canthal distance and the width of anterior teeth and canine cusp width (r = 0.335, r = 0.303. The differences between the two genders were highly significant for all the parameters (p < 0.01. The measured facial distances and width of anterior teeth were higher in men than in women. Conclusion. The results of this study suggest that the examined interalar width and inner canthal distance cannot be considered reliable guidelines in the selection of artificial upper anterior teeth. However, they may be used as a useful additional factor combined with other methods for objective tooth selection. The final decision should be made while working on dentures fitting models with the patient’s consent.

  5. VizieR Online Data Catalog: Blazars equivalent widths and radio luminosity (Landt+, 2004)

    Science.gov (United States)

    Landt, H.; Padovani, P.; Perlman, E. S.; Giommi, P.

    2004-07-01

    Blazars are currently separated into BL Lacertae objects (BL Lacs) and flat spectrum radio quasars based on the strength of their emission lines. This is performed rather arbitrarily by defining a diagonal line in the Ca H&K break value-equivalent width plane, following Marcha et al. (1996MNRAS.281..425M). We readdress this problem and put the classification scheme for blazars on firm physical grounds. We study ~100 blazars and radio galaxies from the Deep X-ray Radio Blazar Survey (DXRBS, Cat. and ) and 2-Jy radio survey and find a significant bimodality for the narrow emission line [OIII]{lambda}5007. This suggests the presence of two physically distinct classes of radio-loud active galactic nuclei (AGN). We show that all radio-loud AGN, blazars and radio galaxies, can be effectively separated into weak- and strong-lined sources using the [OIII]{lambda}5007-[OII]{lambda}3727 equivalent width plane. This plane allows one to disentangle orientation effects from intrinsic variations in radio-loud AGN. Based on DXRBS, the strongly beamed sources of the new class of weak-lined radio-loud AGN are made up of BL Lacs at the ~75 per cent level, whereas those of the strong-lined radio-loud AGN include mostly (~97 per cent) quasars. (4 data files).

  6. The decay width of stringy hadrons

    Directory of Open Access Journals (Sweden)

    Jacob Sonnenschein

    2018-02-01

    We fit the theoretical decay width to experimental data for mesons on the trajectories of ρ, ω, π, η, K⁎, ϕ, D, and Ds⁎, and of the baryons N, Δ, Λ, and Σ. We examine both the linearity in L and the exponential suppression factor. The linearity was found to agree with the data well for mesons but less for baryons. The extracted coefficient for mesons A=0.095±0.015 is indeed quite universal. The exponential suppression was applied to both strong and radiative decays. We discuss the relation with string fragmentation and jet formation. We extract the quark–diquark structure of baryons from their decays. A stringy mechanism for Zweig suppressed decays of quarkonia is proposed and is shown to reproduce the decay width of ϒ states. The dependence of the width on spin and flavor symmetry is discussed. We further apply this model to the decays of glueballs and exotic hadrons.

  7. Intraflow width variations in Martian and terrestrial lava flows

    Science.gov (United States)

    Peitersen, Matthew N.; Crown, David A.

    1997-03-01

    Flow morphology is used to interpret emplacement processes for lava flows on Earth and Mars. Accurate measurements of flow geometry are essential, particularly for planetary flows where neither compositional sampling nor direct observations of active flows may be possible. Width behavior may indicate a flow's response to topography, its emplacement regime, and its physical properties. Variations in width with downflow distance from the vent may therefore provide critical clues to flow emplacement processes. Flow width is also one of the few characteristics that can be readily measured from planetary mission data with accuracy. Recent analyses of individual flows at two terrestrial and four Martian sites show that widths within an individual flow vary by up to an order of magnitude. Width is generally thought to be correlated to topography; however, recent studies show that this relationship is neither straightforward nor easily quantifiable.

  8. Crack widths in concrete with fibers and main reinforcement

    DEFF Research Database (Denmark)

    Christensen, Frede; Ulfkjær, Jens Peder; Brincker, Rune

    2015-01-01

    The main object of the research work presented in this paper is to establish design tools for concrete structures where main reinforcement is combined with addition of short discrete steel fibers. The work is concerned with calculating and measuring crack widths in structural elements subjected...... to bending load. Thus, the aim of the work is to enable engineers to calculate crack widths for flexural concrete members and analyze how different combinations of amounts of fibers and amounts of main reinforcement can meet a given maximum crack width requirement. A mathematical model including...... the ductility of the fiber reinforced concrete (FRC) is set up and experimental work is conducted in order to verify the crack width model. The ductility of the FRC is taken into account by using the stress crack width relation. The constitutive model for the FRC is based on the idea that the initial part...

  9. Bounding the Higgs boson width through interferometry.

    Science.gov (United States)

    Dixon, Lance J; Li, Ye

    2013-09-13

    We study the change in the diphoton-invariant-mass distribution for Higgs boson decays to two photons, due to interference between the Higgs resonance in gluon fusion and the continuum background amplitude for gg→γγ. Previously, the apparent Higgs mass was found to shift by around 100 MeV in the standard model in the leading-order approximation, which may potentially be experimentally observable. We compute the next-to-leading-order QCD corrections to the apparent mass shift, which reduce it by about 40%. The apparent mass shift may provide a way to measure, or at least bound, the Higgs boson width at the Large Hadron Collider through "interferometry." We investigate how the shift depends on the Higgs width, in a model that maintains constant Higgs boson signal yields. At Higgs widths above 30 MeV, the mass shift is over 200 MeV and increases with the square root of the width. The apparent mass shift could be measured by comparing with the ZZ* channel, where the shift is much smaller. It might be possible to measure the shift more accurately by exploiting its strong dependence on the Higgs transverse momentum.

  10. Investigation of channel width-dependent threshold voltage variation in a-InGaZnO thin-film transistors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Kuan-Hsien; Chou, Wu-Ching [Department of Electrophysics, National Chiao Tung University, Hsinchu, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Advanced Optoelectronics Technology Center, National Cheng Kung University, Taiwan (China); Wu, Ming-Siou; Hung, Yi-Syuan; Sze, Simon M. [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, Taiwan (China); Hung, Pei-Hua; Chu, Ann-Kuo [Department of Photonics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Hsieh, Tien-Yu [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Yeh, Bo-Liang [Advanced Display Technology Research Center, AU Optronics, No. 1, Li-Hsin Rd. 2, Hsinchu Science Park, Hsinchu 30078, Taiwan (China)

    2014-03-31

    This Letter investigates abnormal channel width-dependent threshold voltage variation in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Unlike drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, the wider the channel, the larger the threshold voltage observed. Because of the surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider channel devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast IV measurement is utilized to demonstrate the self-heating induced anomalous channel width-dependent threshold voltage variation.

  11. Meson widths from string worldsheet instantons

    International Nuclear Information System (INIS)

    Faulkner, Thomas; Liu, Hong

    2009-01-01

    We show that open strings living on a D-brane which lies outside an AdS black hole can tunnel into the black hole through worldsheet instantons. These instantons have a simple interpretation in terms of thermal quarks in the dual Yang-Mills (YM) theory. As an application we calculate the width of a meson in a strongly coupled quark-gluon plasma which is described holographically as a massless mode on a D7 brane in AdS 5 xS 5 . While the width of the meson is zero to all orders in the 1/√(λ) expansion with λ the 't Hooft coupling, it receives non-perturbative contributions in 1/√(λ) from worldsheet instantons. We find that the width increases quadratically with momentum at large momentum and comment on potential phenomenological implications of this enhancement for heavy ion collisions. We also comment on how this non-perturbative effect has important consequences for the phase structure of the YM theory obtained in the classical gravity limit

  12. Gap Width Study and Fixture Design in Laser Butt-Welding

    DEFF Research Database (Denmark)

    Gong, Hui; Olsen, Flemming Ove

    .5-2.0 m/min, the laser power : 2 and 2.6 kW and the focal point position : 0 and -1.2 mm. Quality of all the butt welds are destructively tested according to ISO 13919-1.Influences of the variable process parameters to the maximum allowable gap width are observed as (1) the maximum gap width is inversely......This paper discusses some practical consideration for design of a mechanical fixture, which enables to accurately measure the width of a gap between two stainless steel workpieces and to steadfastly clamp the workpieces for butt-welding with a high power CO2 laser.With such a fixture, a series...... of butt-welding experiment is successfully carried out in order to find the maximum allowable gap width in laser butt-welding. The gap width study (GWS) is performed on the material of SST of W1.4401 (AISI 316) under various welding conditions, which are the gap width : 0.00-0.50 mm, the welding speed : 0...

  13. Effects of ultra-thin Si-fin body widths upon SOI PMOS FinFETs

    Science.gov (United States)

    Liaw, Yue-Gie; Chen, Chii-Wen; Liao, Wen-Shiang; Wang, Mu-Chun; Zou, Xuecheng

    2018-05-01

    Nano-node tri-gate FinFET devices have been developed after integrating a 14 Å nitrided gate oxide upon the silicon-on-insulator (SOI) wafers established on an advanced CMOS logic platform. These vertical double gate (FinFET) devices with ultra-thin silicon fin (Si-fin) widths ranging from 27 nm to 17 nm and gate length down to 30 nm have been successfully developed with a 193 nm scanner lithography tool. Combining the cobalt fully silicidation and the CESL strain technology beneficial for PMOS FinFETs was incorporated into this work. Detailed analyses of Id-Vg characteristics, threshold voltage (Vt), and drain-induced barrier lowering (DIBL) illustrate that the thinnest 17 nm Si-fin width FinFET exhibits the best gate controllability due to its better suppression of short channel effect (SCE). However, higher source/drain resistance (RSD), channel mobility degradation due to dry etch steps, or “current crowding effect” will slightly limit its transconductance (Gm) and drive current.

  14. Stream Width Dynamics in a Small Headwater Catchment

    Science.gov (United States)

    Barefoot, E. A.; Pavelsky, T.; Allen, G. H.; Zimmer, M. A.; McGlynn, B. L.

    2016-12-01

    Changing streamflow conditions cause small, ephemeral and intermittent stream networks to expand and contract, while simultaneously driving widening and narrowing of streams. The resulting dynamic surface area of ephemeral streams impacts critical hydrological and biogeochemical processes, including air-water gas exchange, solute transport, and sediment transport. Despite the importance of these dynamics, to our knowledge there exists no complete study of how stream widths vary throughout an entire catchment in response to changing streamflow conditions. Here we present the first characterization of how variable hydrologic conditions impact the distribution of stream widths in a 48 ha headwater catchment in the Stony Creek Research Watershed, NC, USA. We surveyed stream widths longitudinally every 5 m on 12 occasions over a range of stream discharge from 7 L/s to 128 L/s at the catchment outlet. We hypothesize that the shape and location of the stream width distribution are driven by the action of two interrelated mechanisms, network extension and at-a-station widening, both of which increase with discharge. We observe that during very low flow conditions, network extension more significantly influences distribution location, and during high flow conditions stream widening is the dominant driver. During moderate flows, we observe an approximately 1 cm rightward shift in the distribution peak with every additional 10 L/s of increased discharge, which we attribute to a greater impact of at-a-station widening on distribution location. Aside from this small shift, the qualitative location and shape of the stream width distribution are largely invariant with changing streamflow. We suggest that the basic characteristics of stream width distributions constitute an equilibrium between the two described mechanisms across variable hydrologic conditions.

  15. Relationship between SEP Peak intensity and CME Acceleration, Speed and Width

    Science.gov (United States)

    Xie, H.; St Cyr, O. C.; Makela, P. A.; Gopalswamy, N.

    2017-12-01

    We study the large solar energetic particle (SEP) events that were detected by GOES in the >10 MeV energy channel during December 2006 to January 2016. Data used in this study includes the Solar Electron Proton Telescope (SEPT) and High Energy Telescopes (HET) on STEREO A and B, the Electron, Proton, and Alpha Monitor (EPAM) on ACE, and the Energetic and Relativistic Nuclei and Electron instrument (ERNE) on SOHO. By choosing the smallest connection angles between SEP solar locations and magnetic foot-points of each spacecraft, we divide SEP events as SOHO SEPs or STEREO SEPs. We then compute the SEP peak intensity I0 at the center of the Gausssian using the Gausssian expression from Richardson et al. (2014) and study the relationship between SEP electron and proton peak intensity and CME acceleration, speed and width. By using I0 derived from multi-spacecraft observations we found that the correlations between SEP peak intensity and CME acceleration and speed improved. We also found that this correlation can be further improved by taking into account the effects of CME width and its solar source latitude. The implication for the SEP forecast of our obtained results will be discussed.

  16. Theoretical aspects of the electronical devices operating due to interaction between annular electron beams and the azimuthal surface waves

    Energy Technology Data Exchange (ETDEWEB)

    Girka, V O; Girka, I O [Kharkiv State Univ. (Ukraine)

    1997-12-31

    The physical basis is discussed of electronic devices whose operation is based on the beam or dissipative instability of the azimuthal surface waves (ASW). The ASW are electromagnetic surface waves with extraordinary polarization (with field components E{sub r}, E{sub {phi}}, H{sub z}), propagating across the axial external steady magnetic field in the cylindrical metal waveguide with cold plasma filling. The ASW fields are described by Maxwell equations. To solve the problem, the authors used the Fourier method and numerical simulation of the equations obtained. The ASW excitation was examined under conditions of beam and dissipative instabilities due to the electron beam motion. The correction to ASW eigenfrequencies caused by the waveguide chamber noncircularity was also studied. ASW delaying leads to a negative frequency correction. The ASW energy can be emitted from the narrow slot in the metallic chamber of the waveguide. The optimum wavenumber range was found where the increment values are much greater than those of the ASW decrement caused by their energy radiation. (author). 2 figs., 3 refs.

  17. A two-level voltage source inverter with differentially sinusoidal pulse width modulation used in the interconnection system of a wind turbine generator

    Directory of Open Access Journals (Sweden)

    Alexandros C. Charalampidis

    2014-10-01

    Full Text Available This study analyses an interconnection system based on differentially sinusoidal pulse width modulation, used for the interconnection to the grid of a variable speed wind turbine. The modulation technique used provides specific advantages in comparison with the commonly used sinusoidal pulse width modulation (SPWM technique, such as lower DC bus voltage requirements, smaller switching losses for the same switching frequency as well as less higher harmonic content in the voltage waveforms produced. The respective control system is also described in detail. Thus this study provides a guide enabling the design of any interconnection system based on this modulation technique.

  18. Widths of the atomic K-N7 levels

    International Nuclear Information System (INIS)

    Campbell, J.L.; Papp, Tibor

    2001-01-01

    Atomic level widths obtained from experimental measurements are collected in Table I, along with the corresponding theoretical widths derived from the Evaluated Atomic Data Library (EADL) of Lawrence Livermore National Laboratory; these EADL values are based upon the Dirac-Hartree-Slater version of the independent-particle model. In a minority of cases, many-body theory predictions are also provided. A brief discussion of the manner in which the experimental widths were deduced from spectroscopic data is included. The bulk of the data are for elements in the solid state, but a few data for gases and simple compounds are included. For the K, L2, L3, and M5 levels, where Coster-Kronig contributions do not contribute or contribute only to a small extent to the overall widths, the EADL predictions appear satisfactory for elements in the solid state. For other levels, where Coster-Kronig and super-Coster-Kronig transitions have large probabilities within the independent-particle model, this model is not satisfactory. Table II provides a complete set of recommended elemental values based upon consideration of the available experimental data

  19. Pulse Width Affects Scalp Sensation of Transcranial Magnetic Stimulation.

    Science.gov (United States)

    Peterchev, Angel V; Luber, Bruce; Westin, Gregory G; Lisanby, Sarah H

    Scalp sensation and pain comprise the most common side effect of transcranial magnetic stimulation (TMS), which can reduce tolerability and complicate experimental blinding. We explored whether changing the width of single TMS pulses affects the quality and tolerability of the resultant somatic sensation. Using a controllable pulse parameter TMS device with a figure-8 coil, single monophasic magnetic pulses inducing electric field with initial phase width of 30, 60, and 120 µs were delivered in 23 healthy volunteers. Resting motor threshold of the right first dorsal interosseus was determined for each pulse width, as reported previously. Subsequently, pulses were delivered over the left dorsolateral prefrontal cortex at each of the three pulse widths at two amplitudes (100% and 120% of the pulse-width-specific motor threshold), with 20 repetitions per condition delivered in random order. After each pulse, subjects rated 0-to-10 visual analog scales for Discomfort, Sharpness, and Strength of the sensation. Briefer TMS pulses with amplitude normalized to the motor threshold were perceived as slightly more uncomfortable than longer pulses (with an average 0.89 point increase on the Discomfort scale for pulse width of 30 µs compared to 120 µs). The sensation of the briefer pulses was felt to be substantially sharper (2.95 points increase for 30 µs compared to 120 µs pulse width), but not stronger than longer pulses. As expected, higher amplitude pulses increased the perceived discomfort and strength, and, to a lesser degree the perceived sharpness. Our findings contradict a previously published hypothesis that briefer TMS pulses are more tolerable. We discovered that the opposite is true, which merits further study as a means of enhancing tolerability in the context of repetitive TMS. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Temperature dependence of giant dipole resonance width

    International Nuclear Information System (INIS)

    Vdovin, A.I.; Storozhenko, A.N.

    2005-01-01

    The quasiparticle-phonon nuclear model extended to finite temperature within the framework of the thermo field dynamics is applied to calculate a temperature dependence of the spreading width Γ d own of a giant dipole resonance. Numerical calculations are made for 12S n and 208 Pb nuclei. It is found that the width Γ d own increases with T. The reason of this effect is discussed as well as a relation of the present approach to other ones existing in the literature

  1. Crack width monitoring of concrete structures based on smart film

    International Nuclear Information System (INIS)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-01-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge. (paper)

  2. Crack width monitoring of concrete structures based on smart film

    Science.gov (United States)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-04-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge.

  3. Morphodynamics structures induced by variations of the channel width

    Science.gov (United States)

    Duro, Gonzalo; Crosato, Alessandra; Tassi, Pablo

    2014-05-01

    In alluvial channels, forcing effects, such as a longitudinally varying width, can induce the formation of steady bars (Olesen, 1984). The type of bars that form, such as alternate, central or multiple, will mainly depend on the local flow width-to-depth ratio and on upstream conditions (Struiksma et al., 1985). The effects on bar formation of varying the channel width received attention only recently and investigations, based on flume experiments and mathematical modelling, are mostly restricted to small longitudinal sinusoidal variations of the channel width (e.g. Repetto et al., 2002; Wu and Yeh, 2005, Zolezzi et al., 2012; Frascati and Lanzoni, 2013). In this work, we analyze the variations in equilibrium bed topography in a longitudinal width-varying channel with characteristic scales of the Waal River (The Netherlands) using two different 2D depth-averaged morphodynamic models, one based on the Delft3D code and one on Telemac-Mascaret system. In particular, we explore the effects of changing the wavelength of sinusoidal width variations in a straight channel, focusing on the effects of the spatial lag between bar formation and forcing that is observed in numerical models and laboratory experiments (e.g. Crosato et al, 2011). We extend the investigations to finite width variations in which longitudinal changes of the width-to-depth ratio are such that they may affect the type of bars that become unstable (alternate, central or multiple bars). Numerical results are qualitatively validated with field observations and the resulting morphodynamic pattern is compared with the physics-based predictor of river bar modes by Crosato and Mosselman (2009). The numerical models are finally used to analyse the experimental conditions of Wu and Yeh (2005). The study should be seen as merely exploratory. The aim is to investigate possible approaches for future research aiming at assessing the effects of artificial river widening and narrowing to control bar formation in

  4. Helium isotope data from the Goldfield epithermal system, Nevada: Evidence for volatile input from a primitive mantle source during ore formation

    Science.gov (United States)

    Hofstra, A. H.; Manning, A. H.

    2013-12-01

    Goldfield is the largest high sulfidation epithermal gold mining district in the United States with over 130 t of gold production and 23 sq. km. of argillic alteration (with alunite, pyrophyllite, or kaolinite). It formed at 20.0×0.5 Ma in an andesite to rhyolite volcanic field in the ancestral Cascades continental magmatic arc. Previous stable isotope studies of quartz, alunite, and sulfide minerals suggest that the gold ores formed in a magmatic vapor plume derived from a subjacent porphyry intrusion, which displaced and mixed with meteoric groundwater at shallow levels. The isotopic compositions of He, Ne, and Ar trapped in fluid inclusions in hydrothermal minerals (Cu-sulfides and sulfosalts, pyrite, quartz) were measured to further constrain volatile source and migration processes. Gases were released by thermal decrepitation at 300°C and analyzed using a high resolution static sector mass spectrometer. The isotopic compositions of Ne and Ar are typical of air-saturated water (ASW), indicating that the samples contain little nucleogenic Ne or radiogenic Ar derived from underlying old crustal sources. In contrast, He/Ne and He/Ar ratios are much greater than ASW, indicating that a component of He was produced in the subsurface. The wide range of He R/Ra values, 0.4 to 20, suggests that He was derived from both crustal and mantle sources. 4He/40Ar* and 4He/21Ne* systematics are characteristic of magma degassing. The highest R/Ra values (15-20) are well above those previously reported for modern volcanic rocks and geothermal fluids in subduction-related arcs. Such R/Ra values indicate a primitive mantle source, perhaps below the subducting slab. We hypothesize that the discharge of metal-laden fluids from the subjacent porphyry intrusion was influenced by the input of hot volatiles from mafic mantle-derived magmas. This scenario implies a magma column that remained open to the flux of volatiles over a considerable depth range, from the mantle to the shallow

  5. Effective spectrum width of the synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V. G., E-mail: bagrov@phys.tsu.ru [Department of Physics, Tomsk State University, Tomsk (Russian Federation); Institute of High Current Electronics, SB RAS, Tomsk (Russian Federation); Gitman, D. M., E-mail: gitman@if.usp.br [Department of Physics, Tomsk State University, Tomsk (Russian Federation); Institute of Physics, University of São Paulo, São Paulo (Brazil); P.N.Lebedev Physical Institute, Moscow (Russian Federation); Levin, A. D., E-mail: alevin@if.usp.br [Institute of Physics, University of São Paulo, São Paulo (Brazil); Loginov, A. S.; Saprykin, A. D. [Department of Physics, Tomsk State University, Tomsk (Russian Federation)

    2015-11-25

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory.

  6. Effective spectrum width of the synchrotron radiation

    International Nuclear Information System (INIS)

    Bagrov, V. G.; Gitman, D. M.; Levin, A. D.; Loginov, A. S.; Saprykin, A. D.

    2015-01-01

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory

  7. Effective spectrum width of the synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); SB RAS, Institute of High Current Electronics, Tomsk (Russian Federation); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); P.N. Lebedev Physical Institute, Moscow (Russian Federation); Levin, A.D. [University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); Loginov, A.S.; Saprykin, A.D. [Tomsk State University, Department of Physics, Tomsk (Russian Federation)

    2015-11-15

    For an exact quantitative description of spectral properties of synchrotron radiation (SR), the concept of effective width of the spectrum is introduced. In the most interesting case, which corresponds to the ultrarelativistic limit of SR, the effective width of the spectrum is calculated for the polarization components, and new physically important quantitative information on the structure of spectral distributions is obtained. For the first time, the spectral distribution for the circular polarization component of the SR for the upper half-space is obtained within classical theory. (orig.)

  8. Suppression of high-frequency perturbations in pulse-width modulation

    DEFF Research Database (Denmark)

    2008-01-01

    A method suppresses high-frequency perturbations in a pulse-width modulated signal. The pulse-width modulation may superpose a carrier signal onto an input signal having a predetermined modulation frequency. The carrier signals may be phase-shifted. The resulting modulated signals may...

  9. Losses analysis of soft magnetic ring core under sinusoidal pulse width modulation (SPWM) and space vector pulse width modulation (SVPWM) excitations

    Science.gov (United States)

    Gao, Hezhe; Li, Yongjian; Wang, Shanming; Zhu, Jianguo; Yang, Qingxin; Zhang, Changgeng; Li, Jingsong

    2018-05-01

    Practical core losses in electrical machines differ significantly from those experimental results using the standardized measurement method, i.e. Epstein Frame method. In order to obtain a better approximation of the losses in an electrical machine, a simulation method considering sinusoidal pulse width modulation (SPWM) and space vector pulse width modulation (SVPWM) waveforms is proposed. The influence of the pulse width modulation (PWM) parameters on the harmonic components in SPWM and SVPWM is discussed by fast Fourier transform (FFT). Three-level SPWM and SVPWM are analyzed and compared both by simulation and experiment. The core losses of several ring samples magnetized by SPWM, SVPWM and sinusoidal alternating current (AC) are obtained. In addition, the temperature rise of the samples under SPWM, sinusoidal excitation are analyzed and compared.

  10. Hydration of ammonia, methylamine, and methanol in amorphous solid water

    Science.gov (United States)

    Souda, Ryutaro

    2016-02-01

    Interactions of polar protic molecules with amorphous solid water (ASW) have been investigated using temperature-programmed desorption and time-of-flight secondary ion mass spectrometry. The ammonia and methylamine are incorporated into the interior of porous ASW films. They are caged by water molecules and are released during water crystallization. In contrast, the methanol-water interaction is not influenced by pores of ASW. The methanol additives tend to survive water crystallization and are released during ASW film evaporation. The hydration of n-hexane in ASW is influenced significantly by methanol additives because n-hexane is accommodated in a methanol-induced hydration shell.

  11. Influence of electrical sheet width on dynamic magnetic properties

    CERN Document Server

    Chevalier, T; Cornut, B

    2000-01-01

    Effects of the width of electrical steel sheets on dynamic magnetic properties are investigated by solving diffusion equation on the cross-section of the sheet. Linear and non-linear cases are studied, and are compared with measurement on Epstein frame. For the first one an analytical solution is found, while for the second, a 2D finite element simulation is achieved. The influence of width is highlighted for a width thickness ratio lower than 10. It is shown that the behaviour modification in such cases is conditioned by the excitation signal waveform, amplitude and also frequency.

  12. Design Options for Thermal Shutdown Circuitry with Hysteresis Width Independent on the Activation Temperature

    Directory of Open Access Journals (Sweden)

    PLESA, C.-S.

    2017-02-01

    Full Text Available This paper presents several design options for implementing a thermal shutdown circuit with hysteretic characteristic, which has two special features: a programmable activation temperature (the upper trip point of the characteristic and a hysteresis width largely insensitive to the actual value of the activation temperature and to variations of the supply voltage. A fairly straightforward architecture is employed, with the hysteresis implemented by a current source enabled by the output of the circuit. Four possible designs are considered for this current source: VBE/R, modified-VBE/R, Widlar and a peaking current source tailored for this circuit. First, a detailed analytical analysis of the circuit implemented with these current sources is performed; it indicates the one best suited for this application and provides key sizing equations. Next, the chosen current source is employed to design the thermal shutdown protection of an integrated Low-Dropout Voltage Regulator (LDO for automotive applications. Simulation results and measurements performed on the silicon implementation fully validate the design. Moreover, they compare favorably with the performance of similar circuits reported recently.

  13. Fast and Robust Nanocellulose Width Estimation Using Turbidimetry.

    Science.gov (United States)

    Shimizu, Michiko; Saito, Tsuguyuki; Nishiyama, Yoshiharu; Iwamoto, Shinichiro; Yano, Hiroyuki; Isogai, Akira; Endo, Takashi

    2016-10-01

    The dimensions of nanocelluloses are important factors in controlling their material properties. The present study reports a fast and robust method for estimating the widths of individual nanocellulose particles based on the turbidities of their water dispersions. Seven types of nanocellulose, including short and rigid cellulose nanocrystals and long and flexible cellulose nanofibers, are prepared via different processes. Their widths are calculated from the respective turbidity plots of their water dispersions, based on the theory of light scattering by thin and long particles. The turbidity-derived widths of the seven nanocelluloses range from 2 to 10 nm, and show good correlations with the thicknesses of nanocellulose particles spread on flat mica surfaces determined using atomic force microscopy. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. High Intensity Source Laboratory (HISL)

    International Nuclear Information System (INIS)

    1992-01-01

    The High Intensity Source Laboratory (HISL) is a laboratory facility operated for the US Department of Energy (DOE) by EG ampersand G, Energy Measurements (EG ampersand G/EM). This document is intended as an overview -- primarily for external users -- of the general purposes and capabilities of HISL; numerous technical details are beyond its scope. Moreover, systems at HISL are added, deleted, and modified to suit current needs, and upgraded with continuing development. Consequently, interested parties are invited to contact the HISL manager for detailed, current, technical, and administrative information. The HISL develops and operates pulsed radiation sources with energies, intensities, and pulse widths appropriate for several applications. Principal among these are development, characterization, and calibration of various high-bandwidth radiation detectors and diagnostic systems. Hardness/vulnerability of electronic or other sensitive components to radiation is also tested. In this connection, source development generally focuses on attending (1) the highest possible intensities with (2) reasonably short pulse widths and (3) comprehensive output characterization

  15. Heuristic drift-based model of the power scrape-off width in low-gas-puff H-mode tokamaks

    International Nuclear Information System (INIS)

    Goldston, R.J.

    2012-01-01

    A heuristic model for the plasma scrape-off width in low-gas-puff tokamak H-mode plasmas is introduced. Grad B and curv B drifts into the scrape-off layer (SOL) are balanced against near-sonic parallel flows out of the SOL, to the divertor plates. The overall particle flow pattern posited is a modification for open field lines of Pfirsch–Schlüter flows to include order-unity sinks to the divertors. These assumptions result in an estimated SOL width of ∼2aρ p /R. They also result in a first-principles calculation of the particle confinement time of H-mode plasmas, qualitatively consistent with experimental observations. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, derived above, with heat from the main plasma. The separatrix temperature is calculated based on a two-point model balancing power input to the SOL with Spitzer–Härm parallel thermal conduction losses to the divertor. This results in a heuristic closed-form prediction for the power scrape-off width that is in reasonable quantitative agreement both in absolute magnitude and in scaling with recent experimental data. Further work should include full numerical calculations, including all magnetic and electric drifts, as well as more thorough comparison with experimental data.

  16. A Comparison Study of Sinusoidal PWM and Space Vector PWM Techniques for Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Ömer Türksoy

    2017-06-01

    Full Text Available In this paper, the methods used to control voltage source inverters which have been intensively investigated in recent years are compared. Although the most efficient result is obtained with the least number of switching elements in the inverter topologies, the method used in the switching is at least as effective as the topology. Besides, the selected switching method to control the inverter will play an effective role in suppressing harmonic components while producing the ideal output voltage. There are many derivatives of pulse width modulation techniques that are commonly used to control voltage source inverters. Some of widespread methods are sinusoidal pulse width modulation and space vector pulse width modulation techniques. These modulation techniques used for generating variable frequency and amplitude output voltage in voltage source inverters, have been simulated by using MATLAB/SIMULINK. And, the total harmonic distortions of the output voltages are compared. As a result of simulation studies, sinusoidal pulse width modulation has been found to have more total harmonic distortion in output voltages of voltage source inverters in the simulation. Space vector pulse width modulation has been shown to produce a more efficient output voltage with less total harmonic distortion.

  17. Conventional power sources for colliders

    International Nuclear Information System (INIS)

    Allen, M.A.

    1987-07-01

    At SLAC we are developing high peak-power klystrons to explore the limits of use of conventional power sources in future linear colliders. In an experimental tube we have achieved 150 MW at 1 μsec pulse width at 2856 MHz. In production tubes for SLAC Linear Collider (SLC) we routinely achieve 67 MW at 3.5 μsec pulse width and 180 pps. Over 200 of the klystrons are in routine operation in SLC. An experimental klystron at 8.568 GHz is presently under construction with a design objective of 30 MW at 1 μsec. A program is starting on the relativistic klystron whose performance will be analyzed in the exploration of the limits of klystrons at very short pulse widths

  18. Voltage control on TEG-inverter system with pulse width modulation

    International Nuclear Information System (INIS)

    Kimura, N.; Kinoshita, H.; Matsuura, K.

    1984-01-01

    An ocean thermoelectric generating system can be expected to supply cheap electric power in future. And it can be used as base power supply or isolated power source in developing areas. The authors propose to apply forced-commutation inverter to thermoelectric energy conversion system and construct an electric power station which can be operated without any other synchronous generator (S-G) and can control ac system as stable as S-G. This paper shows that inverters can control voltage constant, though within a range of 10% load change, by using pulse width modulation (PWM). It also describes the design of the voltage control system covering from 50% to 100% load with combination of PWM and output voltage tap changing of TEG

  19. Correlations for reduced-width amplitudes in 49V

    International Nuclear Information System (INIS)

    Chou, B.H.; Mitchell, G.E.; Bilpuch, E.G.; Westerfeldt, C.R.

    1980-01-01

    Measurement of the relative sign of inelastic proton-channel amplitudes permits the determination of amplitude correlations. Data were obtained for 45 5/2 + resonances in 49 V. Although the reduced widths in each channel followed a Porter-Thomas distribution, large amplitude correlations were observed. The results are compared with the reduced-width--amplitude distribution of Krieger and Porter. This is the first direct test of the Krieger-Porter distribution

  20. Modified model of neutron resonances widths distributions. Results of reduced neutron widths approximation for mass region 35 ≤ A ≤ 249

    International Nuclear Information System (INIS)

    Sukhovoj, A.M.; Khitrov, V.A.

    2011-01-01

    The distributions of the reduced neutron widths of s-, p- and d-resonances of nuclei of any type from nuclear mass region 35 ≤ A ≤ 249 were approximated with maximal precision by the model which presents experimental data set as a superposition of a maximum of four independent neutron amplitudes. Under the assumption that each of these amplitudes has the Gauss distribution with the unique maximum there were determined the most probable values of contribution of each amplitude in summary width distribution, their most probable mean values and dispersions. Comparison of the obtained χ 2 values with value χ 2 at description of the experimental data by one distribution of neutron amplitudes with best fitted parameters shows that all widths from more than 157 analyzed data sets can have different types of wave functions

  1. Correlations between topography and intraflow width behavior in Martian and terrestrial lava flows

    Science.gov (United States)

    Peitersen, Matthew N.; Crown, David A.

    2000-02-01

    Local correlations between topography and width behavior within lava flows at Puu Oo, Mount Etna, Glass Mountain, Cerro Bayo, Alba Patera, Tyrrhena Patera, Elysium Mons, and Olympus Mons were investigated. For each flow, width and slope data were both referenced via downflow distance as a sequence of points; the data were then divided into collections of adjacent three-point features and two-point segments. Four discrete types of analyses were conducted: (1) Three-point analysis examined positional correlations between width and slope features, (2) two-point analysis did the same for flow segments, (3) mean slope analysis included segment slope comparisons, and (4) sudden width behavior analysis measured abruptness of width changes. The distribution of types of correlations compared to random combinations of features and segments does not suggest a significant correlation between flow widths and local underlying slopes and indicates that for these flows at least, other factors have more influence on changes in width than changes in underlying topography. Mean slopes underlying narrowing, widening, and constant flow width segments were calculated. An inverse correlation between slope and width was found only at Mount Etna, where slopes underlying narrowing segments were greater than those underlying widening in 62% of the examined flows. For the majority of flows at Mount Etna, Puu Oo, and Olympus Mons, slopes were actually greatest under constant width segments; this may imply a topographically dependent resistance to width changes. The rate of change of width was also examined. Sudden width changes are relatively common at Puu Oo, Mount Etna, Elysium Mons, and Tyrrhena Patera and relatively rare at Glass Mountain, Cerro Bayo, Olympus Mons, and Alba Patera. After correction for mapping scale, Puu Oo, Mount Etna, Olympus Mons, and Alba Patera appear to fall on the same trend; Glass Mount exhibits unusually small amounts of sudden width behavior, and Tyrrhena Patera

  2. CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENETRATION LENGTH

    International Nuclear Information System (INIS)

    GROEBNER, R.J.; MAHDAVI, M.A.; LEONARD, A.W.; OSBORNE, T.H.; WOLF, N.S.; PORTER, G.D.; STANGEBY, P.C.; BROOKS, N.H.; COLCHIN, R.J.; HEIDBRINK, W.W.; LUCE, T.C.; MCKEE, G.R.; OWEN, L.W.; WANG, G.; WHYTE, D.G.

    2002-01-01

    OAK A271 CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENETRATION LENGTH. Pedestal studies in DIII-D find a good correlation between the width of the H-mode density barrier and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides the dominant control for the size of the H-mode transport barrier

  3. CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENTRATION LENGTH

    International Nuclear Information System (INIS)

    GROEBNER, R.J.; MAHDAVI, M.A.; LEONARD, A.W.; OSBORNE, T.H.; WOLF, N.S.; PORTER, G.D.; STANGEBY, P.C.; BROOKS, N.H.; COLCHIN, R.J.; HEIDBRINK, W.W.; LUCE, T.C.; MCKEE, G.R.; OWEN, L.W.; WANG, G.; WHYTE, D.G.

    2002-01-01

    OAK A271 CORRELATION OF H-MODE BARRIER WIDTH AND NEUTRAL PENTRATION LENGTH. Pedestal studies in DIII-D find a good correlation between the width of the region of steep gradient in the H-mode density and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides a dominant control for the size of the H-mode transport barrier

  4. First Metatarsal Head and Medial Eminence Widths with and Without Hallux Valgus.

    Science.gov (United States)

    Lenz, Robin C; Nagesh, Darshan; Park, Hannah K; Grady, John

    2016-09-02

    Resection of the medial eminence in hallux valgus surgery is common. True hypertrophy of the medial eminence in hallux valgus is debated. No studies have compared metatarsal head width in patients with hallux valgus and control patients. We reviewed 43 radiographs with hallux valgus and 27 without hallux valgus. We measured medial eminence width, first metatarsal head width, and first metatarsal shaft width in patients with and without radiographic hallux valgus. Medial eminence width was 1.12 mm larger in patients with hallux valgus (P hallux valgus (P hallux valgus. However, frontal plane rotation of the first metatarsal likely accounts for this difference.

  5. Modelling the widths of fission observables in GEF

    Directory of Open Access Journals (Sweden)

    Schmidt K.-H.

    2013-03-01

    Full Text Available The widths of the mass distributions of the different fission channels are traced back to the probability distributions of the corresponding quantum oscillators that are coupled to the heat bath, which is formed by the intrinsic degrees of freedom of the fissioning system under the influence of pairing correlations and shell effects. Following conclusion from stochastic calculations of Adeev and Pashkevich, an early freezing due to dynamical effects is assumed. It is shown that the mass width of the fission channels in low-energy fission is strongly influenced by the zero-point motion of the corresponding quantum oscillator. The observed variation of the mass widths of the asymmetric fission channels with excitation energy is attributed to the energy-dependent properties of the heat bath and not to the population of excited states of the corresponding quantum oscillator.

  6. Line width of Josephson flux flow oscillators

    DEFF Research Database (Denmark)

    Koshelets, V.P.; Dmitriev, P.N.; Sobolev, A.S.

    2002-01-01

    to be proven before one initiates real FFO applications. To achieve this goal a comprehensive set of line width measurements of the FFO operating in different regimes has been performed. FFOs with tapered shape have been successfully implemented in order to avoid the superfine resonant structure with voltage...... spacing of about 20 nV and extremely low differential resistance, recently observed in the IVC of the standard rectangular geometry. The obtained results have been compared with existing theories and FFO models in order to understand and possibly eliminate excess noise in the FFO. The intrinsic line width...

  7. Pulse-width discriminators

    International Nuclear Information System (INIS)

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  8. 75 FR 5575 - Taking and Importing Marine Mammals; Navy Training Activities Conducted in the Gulf of Alaska

    Science.gov (United States)

    2010-02-03

    ... and Education Division, Office of Protected Resources, National Marine Fisheries Service, 1315 East... sources will be utilized during Anti-submarine Warfare (ASW) Tracking and Torpedo Exercises, Extended Echo.... Michael Payne, Chief, Division of Permits, Conservation, and Education, Director, Office of Protected...

  9. Constant Width Planar Computation Characterizes ACC0

    DEFF Research Database (Denmark)

    Hansen, K.A.

    2004-01-01

    We obtain a characterization of ACC 0 in terms of a natural class of constant width circuits, namely in terms of constant width polynomial size planar circuits. This is shown via a characterization of the class of acyclic digraphs which can be embedded on a cylinder surface in such a way that all...

  10. Analysis Of The Effect Of Flow Channel Width On The Performance Of PEMFC

    Directory of Open Access Journals (Sweden)

    Elif Eker

    2013-08-01

    Full Text Available In this work, it was analysed the effect of different channel width on performance of PEM fuel cell. Current density were measured on the single cells of parallel flow fields that has 25 cm² active layer, using three different kinds of channel width. The cell width and the channel height remain constant.The results show that increasing the channel width while the cell width remains constant decreases the current density.

  11. Requirements to gap widths and clamping for CO2 laser butt welding

    DEFF Research Database (Denmark)

    Gong, Hui; Juhl, Thomas Winther

    1999-01-01

    In the experimental study of fixturing and gap width requirements a clamping device for laser butt welding of steel sheets has been developed and tested. It has fulfilled the work and made the gap width experiments possible.It has shown that the maximum allowable gap width to some extent...... is inversely related to the welding speed. Also larger laser power leads to bigger allowable gap widths. The focal point position, though, has little influence on the maximum allowable gap width.During analysis X-ray photos show no interior porosity in the weld seam. Other methods have been applied to measure...... responses from variations in welding parameters.The table below lists the results of the study, showing the maximum allowable gap widths and some corresponding welding parameters.Maximum allowable Gap Width; Welding Speed; Laser Power:0.10 mm2 m/min2, 2.6 kW0.15 mm1 m/min2 kW0.20 mm1 m/min2.6 kW0.30 mm0.5 m...

  12. Analysis of the width correlation in 54Fe(nγ)55Fe reaction

    International Nuclear Information System (INIS)

    Knat'ko, V.A.; Shimanovich, E.A.

    1982-01-01

    To find out structural effects manifesting themselves in the form of correlation between widths of different channels of γ decay of levels and violation of Porter-Thomas distribution, calculated are partial widths of levels for 20 high-energy γ transitions in the 54 Fe(nγ) 55 Fe reaction. Calculations are carried out for widths in relation to γ transitions on 8 low p levels of 55 Fe, for 100 sets of partial γ widths (20 widths in a set). Results of analysis of theoretical values of partial γ widths of s resonances are presented in the form of the table. Results, obtained, show that consideration of contributions into γ decay of one-particle-vibrational configurations improve the accordance with experimental data, in comparison with calculations according to the model of valent capture. It is concluded that properties of γ widths of 55 Fe resonances, calculated in studied model, agree satisfactorily with properties of experimental γ widths [ru

  13. Method for Assessment of Changes in the Width of Cracks in Cement Composites with Use of Computer Image Processing and Analysis

    Science.gov (United States)

    Tomczak, Kamil; Jakubowski, Jacek; Fiołek, Przemysław

    2017-06-01

    Crack width measurement is an important element of research on the progress of self-healing cement composites. Due to the nature of this research, the method of measuring the width of cracks and their changes over time must meet specific requirements. The article presents a novel method of measuring crack width based on images from a scanner with an optical resolution of 6400 dpi, subject to initial image processing in the ImageJ development environment and further processing and analysis of results. After registering a series of images of the cracks at different times using SIFT conversion (Scale-Invariant Feature Transform), a dense network of line segments is created in all images, intersecting the cracks perpendicular to the local axes. Along these line segments, brightness profiles are extracted, which are the basis for determination of crack width. The distribution and rotation of the line of intersection in a regular layout, automation of transformations, management of images and profiles of brightness, and data analysis to determine the width of cracks and their changes over time are made automatically by own code in the ImageJ and VBA environment. The article describes the method, tests on its properties, sources of measurement uncertainty. It also presents an example of application of the method in research on autogenous self-healing of concrete, specifically the ability to reduce a sample crack width and its full closure within 28 days of the self-healing process.

  14. Space Vector Pulse Width Modulation of a Multi-Level Diode ...

    African Journals Online (AJOL)

    Space Vector Pulse Width Modulation of a Multi-Level Diode Clamped ... of MATLAB /SIMULINK modeling of the space vector pulse-width modulation and the ... two adjacent active vectors in determining the switching process of the multilevel ...

  15. Attentional Focus and Grip Width Influences on Bench Press Resistance Training.

    Science.gov (United States)

    Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, JuanCarlos; Andersen, Lars L

    2018-04-01

    This study evaluated the influence of different attentional foci for varied grip widths in the bench press. Eighteen resistance-trained men were familiarized with the procedure and performed a one-repetition maximum (1RM) test during Session 1. In Session 2, they used three different standardized grip widths (100%, 150%, and 200% of biacromial width distance) in random order at 50% of 1RM while also engaged in three different attention focus conditions (external focus on the bench press, internal focus on pectoralis major muscles, and internal focus on triceps brachii muscles). Surface electromyography (EMG) signals were recorded from the triceps brachii and pectoralis major, and peak EMG of the filtered signals were normalized to maximum EMG of each muscle. Both grip width and focus influenced the muscle activity level, but there were no significant interactions between these variables. Exploratory analyses suggested that an internal focus may slightly (4%-6%) increase pectoralis major activity at wider grip widths and triceps brachii activity at narrower grip widths, but this should be confirmed or rejected in a study with a larger sample size or through a meta-analysis of research to date.

  16. Analysis on Longitudinal Dose according to Change of Field Width

    International Nuclear Information System (INIS)

    Jung, Won Seok; Shin, Ryung Mi; Oh, Byung Cheon; Jo, Jun Young; Kim, Gi Chul; Choi, Tae Gu; Back, Jong Geal

    2011-01-01

    To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  17. Optimal inverter logic gate using 10-nm double gate-all-around (DGAA transistor with asymmetric channel width

    Directory of Open Access Journals (Sweden)

    Myunghwan Ryu

    2016-01-01

    Full Text Available We investigate the electrical characteristics of a double-gate-all-around (DGAA transistor with an asymmetric channel width using three-dimensional device simulation. The DGAA structure creates a silicon nanotube field-effect transistor (NTFET with a core-shell gate architecture, which can solve the problem of loss of gate controllability of the channel and provides improved short-channel behavior. The channel width asymmetry is analyzed on both sides of the terminals of the transistors, i.e., source and drain. In addition, we consider both n-type and p-type DGAA FETs, which are essential to forming a unit logic cell, the inverter. Simulation results reveal that, according to the carrier types, the location of the asymmetry has a different effect on the electrical properties of the devices. Thus, we propose the N/P DGAA FET structure with an asymmetric channel width to form the optimal inverter. Various electrical metrics are analyzed to investigate the benefits of the optimal inverter structure over the conventional inverter structure. Simulation results show that 27% delay and 15% leakage power improvement are enabled in the optimum structure.

  18. Modeling speed and width parameters of vehicle tires for prediction of the reduction in vehicle noise pollution

    Directory of Open Access Journals (Sweden)

    Amir Esmael Forouhid

    2016-06-01

    Full Text Available Introduction: Safe driving requires the ability of the driver to receive the messages and complying with them. The most significant consequences of noise pollution are on the human auditory system. Disorders in the auditory system can have harmful side effects for human health. By reducing this kind of pollution in large cities, the quality of life, which is one of the biggest goals of the governments, can be considerably increased. Hence, in the present research, some parameters of vehicle tires were examined as a source of noise pollution, and the results can be taken into consideration in noise pollution reduction. Material and Method: Several vehicles with different tire width were selected for measuring sound level. The sound levels were measured for moving vehicles with the use of the Statistical Pass By Method (SPB, ISO 11819-1. Following sound level measurements for moving vehicles and by considering tire width, mathematical model of noise level was predicted on the basis of the obtained information and by usage of SPSS program and considering vehicle tire parameters. Result: The result of this study showed that the vehicle speed and tire width can affect different sound levels emitted by moving tire on road surface. The average speed of vehicles can play an important role in the noise pollution. By increasing speed, rotation of the the tires on the asphalt is increased, as it is a known factors for noise pollution. Moreover, changing the speed of vehicles is accompanied with abnormal sounds of vehicle engine. According to regression model analysis, the obtained value of R2 for the model is 0.8367 which represents the coefficient of determination. Conclusion: The results suggest the main role of the vehicle speed and tire width in increasing the noise reaches to the drivers and consequent noise pollution, which demonstrates the necessity for noise control measures. According to the obtained model, it is understood that changes in noise

  19. Research on Heat Source Model and Weld Profile for Fiber Laser Welding of A304 Stainless Steel Thin Sheet

    Directory of Open Access Journals (Sweden)

    Peizhi Li

    2018-01-01

    Full Text Available A heat source model is the key issue for laser welding simulation. The Gaussian heat source model is not suitable to match the actual laser weld profile accurately. Furthermore, fiber lasers are widely recognized to result in good-quality laser beam output, a narrower weld zone, less distortion, and high process efficiency, compared with other types of lasers (such as CO2, Nd : YAG, and diode lasers. At present, there are few heat source models for fiber laser welding. Most of researchers evaluate the weld profile only by the bead width and depth of penetration, which is not suitable for the laser keyhole welding nail-like profile. This paper reports an experimental study and FEA simulation of fiber laser butt welding on 1 mm thick A304 stainless steel. A new heat source model (cylindrical and cylindrical is established to match the actual weld profile using Marc and Fortran software. Four bead geometry parameters (penetration depth, bead width, waist width, and depth of the waist are used to compare between the experimental and simulation results. The results show that the heat source model of cylindrical and cylindrical can match the actual shape of the fiber laser welding feasibly. The error range of the penetration depth, bead width, waist width, and depth of the waist between experimental and simulation results is about 4.1 ± 1.6%, 2.9 ± 2.0%, 13.6 ± 7.4/%, and 18.3 ± 8.0%, respectively. In addition, it is found that the depth of penetration is more sensitive to laser power rather than bead width, waist width, and depth of the waist. Welding speed has a similar influence on the depth of penetration, weld width, waist width, and depth of the waist.

  20. Neonatal line width in deciduous incisors from Neolithic, mediaeval and modern skeletal samples from north-central Poland.

    Science.gov (United States)

    Kurek, Marta; Żądzińska, Elżbieta; Sitek, Aneta; Borowska-Strugińska, Beata; Rosset, Iwona; Lorkiewicz, Wiesław

    2016-01-01

    The neonatal line is usually the first accentuated incremental line visible on the enamel. The prenatal environment significantly contributes to the width of the neonatal line, influencing the pace of reaching post-delivery homeostasis by the newborn's organism. Studies of the enamel of the earliest developing deciduous teeth can provide an insight into the prenatal development and the perinatal conditions of children of past human populations, thus being an additional source contributing to consideration of the influence of prenatal and perinatal factors modifying growth processes. The aim of this study was to examine whether the neonatal line, reflecting the conditions of the prenatal and perinatal environment, differed between the Neolithic, the mediaeval and the modern populations from the Kujawy region in north-central Poland. The material consisted of longitudinally ground sections of 57 human deciduous incisors obtained from children aged 1.0-7.5 years representing three archaeological series from Brześć Kujawski site. All teeth were sectioned in the labio-linqual plane using a diamond blade (Buechler IsoMet 1000). Final specimens were observed with the microscope Delta Optical Evolution 300 at 10× and 40× magnifications. For each tooth, linear measurements of the neonatal line width were performed on its labial surface at the three levels from the cemento-enamel junction. No significant difference was found in the mean neonatal line width depending on the tooth type and archaeological site, although the thickest neonatal line characterised children from the Neolithic series. In all analysed series, the neonatal line width was diversified depending on the child's age at death. The value of Spearman's rank correlation coefficient calculated for the correlation between the child's age at death and the neonatal line width was statistically significant. A clear increase in the width of the neonatal line was thus observed along with a decrease in the child

  1. Modified vegetation indices for Ganoderma disease detection in oil palm from field spectroradiometer data

    Science.gov (United States)

    Shafri, Helmi Z. M.; Anuar, M. Izzuddin; Saripan, M. Iqbal

    2009-10-01

    High resolution field spectroradiometers are important for spectral analysis and mobile inspection of vegetation disease. The biggest challenges in using this technology for automated vegetation disease detection are in spectral signatures pre-processing, band selection and generating reflectance indices to improve the ability of hyperspectral data for early detection of disease. In this paper, new indices for oil palm Ganoderma disease detection were generated using band ratio and different band combination techniques. Unsupervised clustering method was used to cluster the values of each class resultant from each index. The wellness of band combinations was assessed by using Optimum Index Factor (OIF) while cluster validation was executed using Average Silhouette Width (ASW). 11 modified reflectance indices were generated in this study and the indices were ranked according to the values of their ASW. These modified indices were also compared to several existing and new indices. The results showed that the combination of spectral values at 610.5nm and 738nm was the best for clustering the three classes of infection levels in the determination of the best spectral index for early detection of Ganoderma disease.

  2. Analysis of reduced widths and size

    International Nuclear Information System (INIS)

    Sharma, H.C.; Ram Raj; Nath, N.

    1977-01-01

    Recent data on S-wave neutron reduced widths for a large number of nuclei have been analysed nucleus-wise and the calculations for the degree of freedom of the associated (chi) 2 -distribution have been made using the Porter and Thomas procedure. It is noted that a number of nuclei can be fitted by a (chi) 2 -distribution with degree of freedom one, while there are few which are identified to follow a (chi) 2 -distribution with degree of freedom two and even more than two. The present analysis thus contradicts the usual presumption according to which the degree of freedom is taken to be always unity. An analytical attempt has also been made to ascertain the suitability of the data on reduced widths to be used for the analysis. These considerations are likely to modify the neutron cross-section evaluations. (author)

  3. Dependence of effective spectrum width of synchrotron radiation on particle energy

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Institute of High Current Electronics, Tomsk (Russian Federation); University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); P.N. Lebedev Physical Institute, Moscow (Russian Federation); Levin, A.D. [University of Sao Paulo, Institute of Physics, Sao Paulo (Brazil); Loginov, A.S.; Saprykin, A.D. [Tomsk State University, Department of Physics, Tomsk (Russian Federation)

    2017-05-15

    In the classical theory of synchrotron radiation, for the exact quantitative characterization of spectral properties, the concept of effective spectral width is introduced. In the first part of our work, published in EJPC 75 (2015), the effective spectral width as a function of the energy E of the radiating particle was obtained only in the ultra-relativistic approximation. In this article, which can be considered as a natural continuation of this work, a complete investigation is presented of the dependence of the effective width of the synchrotron radiation spectrum on energy for any values of E and for all the polarization components of the radiation. Numerical calculations were carried out for an effective width not exceeding 100 harmonics. (orig.)

  4. Turbulent transport regimes and the SOL heat flux width

    Science.gov (United States)

    Myra, J. R.; D'Ippolito, D. A.; Russell, D. A.

    2014-10-01

    Understanding the responsible mechanisms and resulting scaling of the scrape-off layer (SOL) heat flux width is important for predicting viable operating regimes in future tokamaks, and for seeking possible mitigation schemes. Simulation and theory results using reduced edge/SOL turbulence models have produced SOL widths and scalings in reasonable accord with experiments in many cases. In this work, we attempt to qualitatively and conceptually understand various regimes of edge/SOL turbulence and the role of turbulent transport in establishing the SOL heat flux width. Relevant considerations include the type and spectral characteristics of underlying instabilities, the location of the gradient drive relative to the SOL, the nonlinear saturation mechanism, and the parallel heat transport regime. Recent SOLT turbulence code results are employed to understand the roles of these considerations and to develop analytical scalings. We find a heat flux width scaling with major radius R that is generally positive, consistent with older results reviewed in. The possible relationship of turbulence mechanisms to the heuristic drift mechanism is considered, together with implications for future experiments. Work supported by US DOE grant DE-FG02-97ER54392.

  5. Comparison of the equivalent width, the autocorrelation width, and the variance as figures of merit for XPS narrow scans

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Bhupinder [Department of Chemistry and Biochemistry, C-100 BNSN, Brigham Young University, Provo, UT 84602 (United States); Velázquez, Daniel; Terry, Jeff [Department of Physics, Illinois Institute of Technology, Chicago, IL 60616 (United States); Linford, Matthew R., E-mail: mrlinford@chem.byu.edu [Department of Chemistry and Biochemistry, C-100 BNSN, Brigham Young University, Provo, UT 84602 (United States)

    2014-12-15

    Highlights: • We apply the equivalent and autocorrelation widths and variance to XPS narrow scans. • This approach is complementary to traditional peak fitting methods. • It is bias free and responsive to subtle chemical changes in spectra. • It has the potential for machine interpretation of spectra and quality control. • It has the potential for analysis of complex spectra and tracking charging/artifacts. - Abstract: X-ray photoelectron spectroscopy (XPS) is widely used in surface and materials laboratories around the world. It is a near surface technique, providing detailed chemical information about samples in the form of survey and narrow scans. To extract the maximum amount of information about materials it is often necessary to peak fit XPS narrow scans. And while indispensable to XPS data analysis, even experienced practitioners can struggle with their peak fitting. In our previous publication, we introduced the equivalent width (EW{sub XPS}) as both a possible machine automated method, one that requires less expert judgment for characterizing XPS narrow scans, and as an approach that may be well suited for the analysis of complex spectra. The EW{sub XPS} figure of merit was applied to four different data sets. However, as previously noted, other width functions are also regularly employed for analyzing functions. Here we evaluate two other width functions for XPS narrow scan analysis: the autocorrelation width (AW{sub XPS}) and the variance (σ{sub XPS}{sup 2}). These widths were applied to the same four sets of spectra studied before: (a) four C 1s narrow scans of ozone-treated carbon nanotubes (CNTs) (EW{sub XPS}: ∼2.11–2.16 eV, AW{sub XPS}: ∼3.9–4.1 eV, σ{sub XPS}{sup 2}: ∼5.0–5.2 eV, and a modified form of σ{sub XPS}{sup 2}, denoted σ{sub XPS}{sup 2*}: ∼6.3–6.8 eV), (b) silicon wafers with different oxide thicknesses (EW{sub XPS}: ∼1.5–2.9 eV, AW{sub XPS}: ∼2.28–4.9, and σ{sub XPS}{sup 2}: ∼0.7–4.9 eV), (iii

  6. The effect of scattering interference term on the practical width

    International Nuclear Information System (INIS)

    Martins do Amaral, C.; Martinez, A.S.

    2001-01-01

    The practical width Γ p has an important application in the characterization of the resonance type for the calculation of neutron average cross sections. Previous treatments ignore the interference term χζ,x for the Doppler broadening function in the practical width calculation. In the present paper, a rational approximation for the χζ,x function is derived, using a modified asymptotic Pade method. A new approximation for Γ p is obtained. The results which are presented here provide evidence that the practical width as a function of temperature varies considerably with the inclusion of the interference term χζ,x

  7. Capacitor charging FET switcher with controller to adjust pulse width

    Science.gov (United States)

    Mihalka, Alex M.

    1986-01-01

    A switching power supply includes an FET full bridge, a controller to drive the FETs, a programmable controller to dynamically control final output current by adjusting pulse width, and a variety of protective systems, including an overcurrent latch for current control. Power MOSFETS are switched at a variable frequency from 20-50 kHz to charge a capacitor load from 0 to 6 kV. A ferrite transformer steps up the DC input. The transformer primary is a full bridge configuration with the FET switches and the secondary is fed into a high voltage full wave rectifier whose output is connected directly to the energy storage capacitor. The peak current is held constant by varying the pulse width using predetermined timing resistors and counting pulses. The pulse width is increased as the capacitor charges to maintain peak current. A digital ripple counter counts pulses, and after the desired number is reached, an up-counter is clocked. The up-counter output is decoded to choose among different resistors used to discharge a timing capacitor, thereby determining the pulse width. A current latch shuts down the supply on overcurrent due to either excessive pulse width causing transformer saturation or a major bridge fault, i.e., FET or transformer failure, or failure of the drive circuitry.

  8. A microelectrostatic repulsive-torque rotation actuator with two-width fingers

    International Nuclear Information System (INIS)

    Fan, Chao; He, Siyuan

    2015-01-01

    A microelectrostatic repulsive-torque rotation actuator with two-width fingers is presented. The actuator consists of finger-shaped electrodes and is made of two thin film layers, i.e. one movable layer and one fixed layer. There are two types of finger electrodes, namely constant-width and two-width fingers. The two-width finger has a narrow lower segment and a wide top segment. The constant-width finger has only the narrow lower segment. Each rotation finger has its corresponding aligned and unaligned fixed fingers. The electrostatic repulsive torque is generated and acts on the rotation fingers to rotate them up and away from the substrate. As a result, rotation is not limited by the gap between the movable and fixed layers and the ‘pull-in’ instability is avoided. Thus a large out-of-plane rotation and high operational stability can be achieved. The actuator is suitable for two-layer surface micromachining. The model of the actuator is developed. Prototypes are fabricated and tested. The experimental tests show that the actuator achieved a mechanical rotation of 7.65° at a driving voltage of 150 V. The settling time for a mechanical rotation of 5° is 5.7 ms. (paper)

  9. Quantum numbers and decay widths of the psi (3684)

    International Nuclear Information System (INIS)

    Luth, V.; Boyarski, A.M.; Lynch, H.L.; Breidenbach, M.; Bulos, F.; Feldman, G.J.; Fryberger, D.; Hanson, G.; Hartill, D.L.; Jean-Marie, B.; Larsen, R.R.; Luke, D.; Morehouse, C.C.; Paterson, J.M.; Perl, M.L.; Pun, T.P.; Rapidis, P.; Richter, B.; Schwitters, R.F.; Tanenbaum, W.; Vannucci, F.; Abrams, G.S.; Chinowsky, W.; Friedberg, C.E.; Goldhaber, G.; Kadyk, J.A.; Litke, A.M.; Lulu, B.A.; Pierre, F.M.; Sadoulet, B.; Trilling, G.H.; Whitaker, J.S.; Winkelmann, F.C.; Wiss, J.E.

    1975-01-01

    Cross sections for e + e - →hadrons, e + e - , and μ + μ - near 3684 MeV are presented. The psi(3684) resonance is established as having the assignment J/sup PC/=1 -- . The mass is 3684+-5 MeV. The partial width for decay to electrons is GAMMA/sube/=2.1+-0.3 keV and the total width is GAMMA=228+-56 keV

  10. Correlation of H-mode barrier width and neutral penetration length

    International Nuclear Information System (INIS)

    Groebner, R.J.; Mahdavi, M.A.; Leonard, A.W.

    2003-01-01

    Pedestal studies in DIII-D find a good correlation between the width of the H-mode density barrier and the neutral penetration length. These results are obtained by comparing experimental density profiles to the predictions of an analytic model for the profile, obtained from the particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40-500 eV), the analytic model quantitatively predicts the observed decrease of the width as the pedestal density increases, the observed strong increase of the gradient of the density as the pedestal density increases and the observation that L-mode and H-mode profiles with the same pedestal density have very similar shapes. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fueling provides the dominant control for the size of the H-mode transport barrier. (author)

  11. Effects of injection nozzle exit width on rotating detonation engine

    Science.gov (United States)

    Sun, Jian; Zhou, Jin; Liu, Shijie; Lin, Zhiyong; Cai, Jianhua

    2017-11-01

    A series of numerical simulations of RDE modeling real injection nozzles with different exit widths are performed in this paper. The effects of nozzle exit width on chamber inlet state, plenum flowfield and detonation propagation are analyzed. The results are compared with that using an ideal injection model. Although the ideal injection model is a good approximation method to model RDE inlet, the two-dimensional effects of real nozzles are ignored in the ideal injection model so that some complicated phenomena such as the reflected waves caused by the nozzle walls and the reversed flow into the nozzles can not be modeled accurately. Additionally, the ideal injection model overpredicts the block ratio. In all the cases that stabilize at one-wave mode, the block ratio increases as the nozzle exit width gets smaller. The dual-wave mode case also has a relatively high block ratio. A pressure oscillation in the plenum with the same main frequency with the rotating detonation wave is observed. A parameter σ is applied to describe the non-uniformity in the plenum. σ increases as the nozzle exit width gets larger. Under some condition, the heat release on the interface of fresh premixed gas layer and detonation products can be strong enough to induce a new detonation wave. A spontaneous mode-transition process is observed for the smallest exit width case. Due to the detonation products existing in the premixed gas layer before the detonation wave, the detonation wave will propagate through reactants and products alternately, and therefore its strength will vary with time, especially near the chamber inlet. This tendency gets weaker as the injection nozzle exit width increases.

  12. SM Higgs decay branching ratios and total Higgs width

    CERN Multimedia

    Daniel Denegri

    2001-01-01

    Upper: Higgs decay ratios as a function of Higgs mass. The largest branching ratio is not necessarily the most usefull one. The most usefull ones are gamma gamma bbar ZZ and WW as in those modes latter signal to background ratios can be achieved. Lower: Total Higgs decay width versus Higgs mass. At low masses the natural width is extremely small, thus observability depends on instrumental resolution primarily.

  13. Quercus macrocarpa annual, early- and latewood widths as hydroclimatic proxies, southeastern Saskatchewan, Canada

    International Nuclear Information System (INIS)

    Vanstone, Jessica R; Sauchyn, David J

    2010-01-01

    Fluctuations in size of annual ring-widths of Quercus species suggest that environmental factors influence the size and density of vessels within the ring, either by acting as a limiting factor for growth or through fine tuning of the wood structure to environmental factors. The purpose of this study is to assess the potential of Q. macrocarpa to provide multiple dendroclimatic proxies for the Canadian Prairies, by investigating growth responses of annual, early- and latewood widths to regional climate variability. Results indicate that ring width chronologies, from southeastern Saskatchewan capture regional signals related to moisture and drought conditions. Correlations suggest that late-wood widths are more representative of annual ring-widths, than are early-wood widths, and are the best proxy of seasonal fluctuations in climate. Thus regression models that include latewood widths were able to account for more variance in the Palmer Drought Severity Index (PDSI) than when annual ring-widths are used as the only proxy. This study demonstrates that Q. macrocarpa can provide multiple dendroclimatic proxies for investigating large scale climatic fluctuations at annual and sub-annual time scales. It is novel in terms of sub-annual analysis of tree-rings in a region that previously lacked dendrochronological research.

  14. Drift-based Model for Power Scrape-off Width in Low-Gas-Puff H-mode Plasmas: Theory and Implications

    Energy Technology Data Exchange (ETDEWEB)

    Goldston, R., E-mail: rgoldston@pppl.gov [Princeton Plasma Physics Laboratory, Princeton (United States)

    2012-09-15

    Full text: A heuristic model for the plasma scrape-off width in low-gas-puff tokamak H-mode plasmas is introduced. {nabla}B and curvature drifts into the scrape-off layer (SOL) are balanced against near-sonic parallel flows out of the SOL, to the divertor plates. These assumptions result in an estimated SOL width of order the poloidal gyroradius. It is next assumed that anomalous perpendicular electron thermal diffusivity is the dominant source of heat flux across the separatrix, investing the SOL width, derived above, with heat from the main plasma. The separatrix temperature is then calculated based on a two-point model balancing power input to the SOL with Spitzer-Hiarm parallel thermal conduction losses to the divertor. This results in a heuristic closed-form prediction for the power scrape-off width that is in quantitative agreement both in absolute magnitude and in scaling with recent experimental data. The applicability of the Spitzer-Harm model to this regime can be questioned at the lowest densities, where the presence of a sheath can raise the divertor target electron temperature. A more general two-point model including a finite ratio of divertor target to upstream electron temperature shows only a 5% effect on the SOL width with target temperature f{sub T} = 75% of upstream, so this effect is likely negligible in experimentally relevant regimes. To achieve the near-sonic flows measured experimentally, and assumed in this model, sets requirements on the ratio of upstream to total SOL particle sources relative to the square-root of the ratio of target to upstream temperature. As a result very high recycling regimes may allow significantly wider power fluxes. The Pfisch-Schluter model for equilibrium flows has been modified to allow near-sonic flows, appropriate for gradient scale lengths of order the poloidal gyroradius. This results in a new quadrupole flow pattern that amplifies the usual P-S flows at the outer midplane, while reducing them at the inner

  15. Investigation on a Novel Discontinuous Pulse-Width Modulation Algorithm for Single-phase Voltage Source Rectifier

    DEFF Research Database (Denmark)

    Qu, Hao; Yang, Xijun; Guo, Yougui

    2014-01-01

    Single-phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). Single-phase VSC...

  16. Practical algorithms for linear boolean-width

    NARCIS (Netherlands)

    ten Brinke, C.B.; van Houten, F.J.P.; Bodlaender, H.L.

    2015-01-01

    In this paper, we give a number of new exact algorithms and heuristics to compute linear boolean decompositions, and experimentally evaluate these algorithms. The experimental evaluation shows that significant improvements can be made with respect to running time without increasing the width of the

  17. Practical algorithms for linear Boolean-width

    NARCIS (Netherlands)

    ten Brinke, C.B.; van Houten, F.J.P.; Bodlaender, H.L.

    2015-01-01

    In this paper, we give a number of new exact algorithms and heuristics to compute linear boolean decompositions, and experimentally evaluate these algorithms. The experimental evaluation shows that significant improvements can be made with respect to running time without increasing the width of the

  18. Stream water responses to timber harvest: Riparian buffer width effectiveness

    Science.gov (United States)

    Barton D. Clinton

    2011-01-01

    Vegetated riparian buffers are critical for protecting aquatic and terrestrial processes and habitats in southern Appalachian ecosystems. In this case study, we examined the effect of riparian buffer width on stream water quality following upland forest management activities in four headwater catchments. Three riparian buffer widths were delineated prior to cutting; 0m...

  19. Attention demanding tasks during treadmill walking reduce step width variability in young adults

    Directory of Open Access Journals (Sweden)

    Troy Karen L

    2005-08-01

    Full Text Available Abstract Background The variability of step time and step width is associated with falls by older adults. Further, step time is significantly influenced when performing attention demanding tasks while walking. Without exception, step time variability has been reported to increase in normal and pathologically aging older adults. Because of the role of step width in managing frontal plane dynamic stability, documenting the influence of attention-demanding tasks on step width variability may provide insight to events that can disturb dynamic stability during locomotion and increase fall risk. Preliminary evidence suggests performance of an attention demanding task significantly decreases step width variability of young adults walking on a treadmill. The purpose of the present study was to confirm or refute this finding by characterizing the extent and direction of the effects of a widely used attention demanding task (Stroop test on the step width variability of young adults walking on a motorized treadmill. Methods Fifteen healthy young adults walked on a motorized treadmill at a self-selected velocity for 10 minutes under two conditions; without performing an attention demanding task and while performing the Stroop test. Step width of continuous and consecutive steps during the collection was derived from the data recorded using a motion capture system. Step width variability was computed as the standard deviation of all recorded steps. Results Step width decreased four percent during performance of the Stroop test but the effect was not significant (p = 0.10. In contrast, the 16 percent decrease in step width variability during the Stroop test condition was significant (p = 0.029. Conclusion The results support those of our previous work in which a different attention demanding task also decreased step width variability of young subjects while walking on a treadmill. The decreased step width variability observed while performing an attention

  20. Analysis and Minimization of Output Current Ripple for Discontinuous Pulse-Width Modulation Techniques in Three-Phase Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2016-05-01

    Full Text Available This paper gives the complete analysis of the output current ripple in three-phase voltage source inverters considering the different discontinuous pulse-width modulation (DPWM strategies. In particular, peak-to-peak current ripple amplitude is analytically evaluated over the fundamental period and compared among the most used DPWMs, including positive and negative clamped (DPWM+ and DPWM−, and the four possible combinations between them, usually named as DPWM0, DPWM1, DPWM2, and DPWM3. The maximum and the average values of peak-to-peak current ripple are estimated, and a simple method to correlate the ripple envelope with the ripple rms is proposed and verified. Furthermore, all the results obtained by DPWMs are compared to the centered pulse-width modulation (CPWM, equivalent to the space vector modulation to identify the optimal pulse-width modulation (PWM strategy as a function of the modulation index, taking into account the different average switching frequency. In this way, the PWM technique providing for the minimum output current ripple is identified over the whole modulation range. The analytical developments and the main results are experimentally verified by current ripple measurements with a three-phase PWM inverter prototype supplying an induction motor load.

  1. Exotic meson decay widths using lattice QCD

    International Nuclear Information System (INIS)

    Cook, M. S.; Fiebig, H. R.

    2006-01-01

    A decay width calculation for a hybrid exotic meson h, with J PC =1 -+ , is presented for the channel h→πa 1 . This quenched lattice QCD simulation employs Luescher's finite box method. Operators coupling to the h and πa 1 states are used at various levels of smearing and fuzzing, and at four quark masses. Eigenvalues of the corresponding correlation matrices yield energy spectra that determine scattering phase shifts for a discrete set of relative πa 1 momenta. Although the phase shift data is sparse, fits to a Breit-Wigner model are attempted, resulting in a decay width of about 60 MeV when averaged over two lattice sizes having a lattice spacing of 0.07 fm

  2. Width of electromagnetic wave instability spectrum in tungsten plate

    International Nuclear Information System (INIS)

    Rinkevich, A.B.

    1995-01-01

    Based on the study of high-frequency signal modulation and spectrum analysis of the envelope a measurement of spectrum width for electromagnetic wave instability was carried out under conditions of current pulse action on tungsten plate in magnetic field. The existence of amplitude-frequency wave modulation was revealed. The width of current disturbance spectrum in a specimen was evaluated. Current disturbances are shown to cause the instability of electromagnetic wave. 11 refs.; 6 figs

  3. Estimating the Spectral Width of a Narrowband Optical Signal

    DEFF Research Database (Denmark)

    Lading, Lars; Skov Jensen, A.

    1980-01-01

    Methods for estimating the spectral width of a narrowband optical signal are investigated. Spectral analysis and Fourier spectroscopy are compared. Optimum and close-to-optimum estimators are developed under the constraint of having only one photodetector.......Methods for estimating the spectral width of a narrowband optical signal are investigated. Spectral analysis and Fourier spectroscopy are compared. Optimum and close-to-optimum estimators are developed under the constraint of having only one photodetector....

  4. Operational experience with the BNL magnetron H- source

    International Nuclear Information System (INIS)

    Witkover, R.L.

    1983-01-01

    A magnetron H - source with a grooved cathode has been in operation at the BNL Linac for over 18 months. The source has run at 5 pps with a 600 μsec pulse width for periods as long as 5 months. Its development and performance will be discussed

  5. Comparison of tibiofemoral joint space width measurements from standing CT and fixed flexion radiography.

    Science.gov (United States)

    Segal, Neil A; Frick, Eric; Duryea, Jeffrey; Nevitt, Michael C; Niu, Jingbo; Torner, James C; Felson, David T; Anderson, Donald D

    2017-07-01

    The objective of this project was to determine the relationship between medial tibiofemoral joint space width measured on fixed-flexion radiographs and the three-dimensional joint space width distribution on low-dose, standing CT (SCT) imaging. At the 84-month visit of the Multicenter Osteoarthritis Study, 20 participants were recruited. A commercial SCT scanner for the foot and ankle was modified to image knees while standing. Medial tibiofemoral joint space width was assessed on radiographs at fixed locations from 15% to 30% of compartment width using validated software and on SCT by mapping the distances between three-dimensional subchondral bone surfaces. Individual joint space width values from radiographs were compared with three-dimensional joint space width values from corresponding sagittal plane locations using paired t-tests and correlation coefficients. For the four medial-most tibiofemoral locations, radiographic joint space width values exceeded the minimal joint space width on SCT by a mean of 2.0 mm and were approximately equal to the 61st percentile value of the joint space width distribution at each respective sagittal-plane location. Correlation coefficients at these locations were 0.91-0.97 and the offsets between joint space width values from radiographs and SCT measurements were consistent. There were greater offsets and variability in the offsets between modalities closer to the tibial spine. Joint space width measurements on fixed-flexion radiographs are highly correlated with three-dimensional joint space width from SCT. In addition to avoiding bony overlap obscuring the joint, a limitation of radiographs, the current study supports a role for SCT in the evaluation of tibiofemoral OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1388-1395, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Statistical analysis of s-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Pandita Anita; Agrawal, H.M.

    1992-01-01

    The fluctuations of the s-wave neutron reduced widths for many nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the s-wave neutron reduced widths of nuclei follow single channel Porter Thomas distribution (x 2 -distribution with degree of freedom ν = 1) for most of the cases. However there are apparent deviations from ν = 1 and possible explanation and significance of this deviation is given. These considerations are likely to modify the evaluation of neutron cross section. (author)

  7. Alluvial cover controlling the width, slope and sinuosity of bedrock channels

    Science.gov (United States)

    Turowski, Jens Martin

    2018-02-01

    Bedrock channel slope and width are important parameters for setting bedload transport capacity and for stream-profile inversion to obtain tectonics information. Channel width and slope development are closely related to the problem of bedrock channel sinuosity. It is therefore likely that observations on bedrock channel meandering yields insights into the development of channel width and slope. Active meandering occurs when the bedrock channel walls are eroded, which also drives channel widening. Further, for a given drop in elevation, the more sinuous a channel is, the lower is its channel bed slope in comparison to a straight channel. It can thus be expected that studies of bedrock channel meandering give insights into width and slope adjustment and vice versa. The mechanisms by which bedrock channels actively meander have been debated since the beginning of modern geomorphic research in the 19th century, but a final consensus has not been reached. It has long been argued that whether a bedrock channel meanders actively or not is determined by the availability of sediment relative to transport capacity, a notion that has also been demonstrated in laboratory experiments. Here, this idea is taken up by postulating that the rate of change of both width and sinuosity over time is dependent on bed cover only. Based on the physics of erosion by bedload impacts, a scaling argument is developed to link bedrock channel width, slope and sinuosity to sediment supply, discharge and erodibility. This simple model built on sediment-flux-driven bedrock erosion concepts yields the observed scaling relationships of channel width and slope with discharge and erosion rate. Further, it explains why sinuosity evolves to a steady-state value and predicts the observed relations between sinuosity, erodibility and storm frequency, as has been observed for meandering bedrock rivers on Pacific Arc islands.

  8. Alluvial cover controlling the width, slope and sinuosity of bedrock channels

    Directory of Open Access Journals (Sweden)

    J. M. Turowski

    2018-02-01

    Full Text Available Bedrock channel slope and width are important parameters for setting bedload transport capacity and for stream-profile inversion to obtain tectonics information. Channel width and slope development are closely related to the problem of bedrock channel sinuosity. It is therefore likely that observations on bedrock channel meandering yields insights into the development of channel width and slope. Active meandering occurs when the bedrock channel walls are eroded, which also drives channel widening. Further, for a given drop in elevation, the more sinuous a channel is, the lower is its channel bed slope in comparison to a straight channel. It can thus be expected that studies of bedrock channel meandering give insights into width and slope adjustment and vice versa. The mechanisms by which bedrock channels actively meander have been debated since the beginning of modern geomorphic research in the 19th century, but a final consensus has not been reached. It has long been argued that whether a bedrock channel meanders actively or not is determined by the availability of sediment relative to transport capacity, a notion that has also been demonstrated in laboratory experiments. Here, this idea is taken up by postulating that the rate of change of both width and sinuosity over time is dependent on bed cover only. Based on the physics of erosion by bedload impacts, a scaling argument is developed to link bedrock channel width, slope and sinuosity to sediment supply, discharge and erodibility. This simple model built on sediment-flux-driven bedrock erosion concepts yields the observed scaling relationships of channel width and slope with discharge and erosion rate. Further, it explains why sinuosity evolves to a steady-state value and predicts the observed relations between sinuosity, erodibility and storm frequency, as has been observed for meandering bedrock rivers on Pacific Arc islands.

  9. Form factors and radiation widths of the giant multipole resonances

    International Nuclear Information System (INIS)

    Denisov, V.Yu.

    1990-01-01

    Simple analytic relations for the form factors of inelastic electron scattering in the Born approximation and radiation widths of the isovector and isoscalar giant multipole resonances are derived. The dynamic relationship between the volume and surface density vibrations were taken into account in this calculation. The form factors in the Born approximation were found to be in satisfactory agreement with experimental data in the region of small transferred momenta. The radiation widths of isoscalar multipole resonances increase when the number of nucleons increase as A 1/3 , and for isovector resonances this dependence has the form f(A)A 1/3 , where f(A) is a slowly increasing function of A. Radiation widths well fit the experimental data

  10. Development and Performance Evaluation of Light Shelves Using Width-Adjustable Reflectors

    Directory of Open Access Journals (Sweden)

    Heangwoo Lee

    2018-01-01

    Full Text Available In recent years, there has been an increase in the consumption of energy for lighting purposes, which has led to an increase in the number of studies being conducted on this subject. Most studies have focused on light shelves, which are daylighting systems used for reducing the lighting energy required for the interiors of buildings. However, the existing light shelves cannot actively deal with external environmental factors, which often lead to an infringement of the right to light during the night when the performance of the light shelf deteriorates. Therefore, in this study, we propose a light shelf with a width-adjustable reflector and verify its validity using a testbed. The reflector of the proposed light shelf system is modularized so that the length can be adjusted in stages. The optimum width of the light shelf is calculated in terms of the energy reduction and uniformity ratio improvement, and the obtained optimum width is varied depending on the season. We find that the width-adjustable reflector can save 20% and 21.6% more lighting energy than light shelves with fixed reflector widths of 0.3 m and 0.6 m, respectively.

  11. The Width of High Burnup Structure in LWR UO2 Fuel

    International Nuclear Information System (INIS)

    Koo, Yang-Hyun; Lee, Byung-Ho; Oh, Jae-Yong; Sohn, Dong-Seong

    2007-01-01

    The measured data available in the open literature on the width of high burnup structure (HBS) in LWR UO 2 fuel were analyzed in terms of pellet average burnup, enrichment, and grain size. Dependence of the HBS width on pellet average burnup was shown to be divided into three regions; while the HBS width is governed by accumulation of fission damage (i.e., burnup) for burnup below 60 GWd/tU, it seems to be restricted to some limiting value of around 1.5 mm for burnup above 75 GWd/tU due to high temperature which might have caused extensive annealing of irradiation damage. As for intermediate burnup between 60 and 75 GWd/tU, although temperature would not have been so high as to induce extensive annealing, the microstructural damage could have been partly annealed, resulting in the reduction of the HBS width. It was found that both enrichment and grain size also affects the HBS width. However, as long as the pellet average burnup is lower than about 75 GWd/tU, the effect does not appear to be significant for the enrichment and grain size that are typically used in current LWR fuel. (authors)

  12. Enhanced Synaptic Transmission at the Squid Giant Synapse by Artificial Seawater Based on Physically Modified Saline

    Directory of Open Access Journals (Sweden)

    Soonwook eChoi

    2014-02-01

    Full Text Available Superfusion of the squid giant synapse with artificial seawater (ASW based on isotonic saline containing oxygen nanobubbles (RNS60 ASW generates an enhancement of synaptic transmission. This was determined by examining the postsynaptic response to single and repetitive presynaptic spike activation, spontaneous transmitter release, and presynaptic voltage clamp studies. In the presence of RNS60 ASW single presynaptic stimulation elicited larger postsynaptic potentials (PSP and more robust recovery from high frequency stimulation than in control ASW. Analysis of postsynaptic noise revealed an increase in spontaneous transmitter release with modified noise kinetics in RNS60 ASW. Presynaptic voltage clamp demonstrated an increased EPSP, without an increase in presynaptic ICa⁺⁺ amplitude during RNS60 ASW superfusion. Synaptic release enhancement reached stable maxima within 5 to 10 minutes of RNS60 ASW superfusion and was maintained for the entire recording time, up to one hour. Electronmicroscopic morphometry indicated a decrease in synaptic vesicle density and the number at active zones with an increase in the number of clathrin-coated vesicles and large endosome-like vesicles near junctional sites. Block of mitochondrial ATP synthesis by presynaptic injection of oligomycin reduced spontaneous release and prevented the synaptic noise increase seen in RNS60 ASW. After ATP block the number of vesicles at the active zone and clathrin-coated vesicles was reduced, with an increase in large vesicles. The possibility that RNS60 ASW acts by increasing mitochondrial ATP synthesis was tested by direct determination of ATP levels in both presynaptic and postsynaptic structures. This was implemented using luciferin/luciferase photon emission, which demonstrated a marked increase in ATP synthesis following RNS60 administration. It is concluded that RNS60 positively modulates synaptic transmission by up-regulating ATP synthesis, thus leading to synaptic

  13. Enhanced synaptic transmission at the squid giant synapse by artificial seawater based on physically modified saline

    Science.gov (United States)

    Choi, Soonwook; Yu, Eunah; Rabello, Guilherme; Merlo, Suelen; Zemmar, Ajmal; Walton, Kerry D.; Moreno, Herman; Moreira, Jorge E.; Sugimori, Mutsuyuki; Llinás, Rodolfo R.

    2014-01-01

    Superfusion of the squid giant synapse with artificial seawater (ASW) based on isotonic saline containing oxygen nanobubbles (RNS60 ASW) generates an enhancement of synaptic transmission. This was determined by examining the postsynaptic response to single and repetitive presynaptic spike activation, spontaneous transmitter release, and presynaptic voltage clamp studies. In the presence of RNS60 ASW single presynaptic stimulation elicited larger postsynaptic potentials (PSP) and more robust recovery from high frequency stimulation than in control ASW. Analysis of postsynaptic noise revealed an increase in spontaneous transmitter release with modified noise kinetics in RNS60 ASW. Presynaptic voltage clamp demonstrated an increased EPSP, without an increase in presynaptic ICa++ amplitude during RNS60 ASW superfusion. Synaptic release enhancement reached stable maxima within 5–10 min of RNS60 ASW superfusion and was maintained for the entire recording time, up to 1 h. Electronmicroscopic morphometry indicated a decrease in synaptic vesicle density and the number at active zones with an increase in the number of clathrin-coated vesicles (CCV) and large endosome-like vesicles near junctional sites. Block of mitochondrial ATP synthesis by presynaptic injection of oligomycin reduced spontaneous release and prevented the synaptic noise increase seen in RNS60 ASW. After ATP block the number of vesicles at the active zone and CCV was reduced, with an increase in large vesicles. The possibility that RNS60 ASW acts by increasing mitochondrial ATP synthesis was tested by direct determination of ATP levels in both presynaptic and postsynaptic structures. This was implemented using luciferin/luciferase photon emission, which demonstrated a marked increase in ATP synthesis following RNS60 administration. It is concluded that RNS60 positively modulates synaptic transmission by up-regulating ATP synthesis, thus leading to synaptic transmission enhancement. PMID:24575037

  14. Spectral line profile analysis for evaluation of Gaussian and Lorentzian widths and collisional broadening coefficient

    International Nuclear Information System (INIS)

    Nakhate, S.G.; Ahmad, S.A.; Pushpa; Rao, M.; Saksena, G.D.

    1991-01-01

    Deconvolution of atomic line profiles, recorded on PC interfaced recording Fabry-Perot spectrometer, into its Lorentzian and Gaussian component has been carried out. Effect of various parameters of hollow cathode discharge lamp (light source) such as discharge current, bath temperature and gas pressure on Lorentzian and Gaussian width has been studied. The value of the self-broadening coefficient for neon-neon atomic interaction for the transition 2p 5 4P-2P 5 3s (λ=3472.571 A) has been determined. (author). 15 refs., 6 figs., 4 tabs

  15. Statistical distribution of partial widths in the microscopic theory of nuclear reactions

    International Nuclear Information System (INIS)

    Bunakov, V.E.; Ogloblin, S.G.

    1978-01-01

    Using the microscopic theory of nuclear reaction the distribution function of neutron reduced partial widths is obtained. It is shown that the distribution of reduced partial widths of a radiative transition is of the same form. The distribution obtained differs from the Porter-Thomas law for neutron widths only in the presence of intermediate structures. It is noteworthy that the presence of an intermediate structure leads to a greater dispersion

  16. Radiative width of molecular-cluster states

    International Nuclear Information System (INIS)

    Alhassid, Y.; Gai, M.; Bertsch, G.F.

    1982-01-01

    Molecular states are characterized by enhanced electromagnetic deexcitations of many different multipolarities. The expected enhancement of E1, E2, and E3 transitions is examined by deriving molecular sum rules for radiative deexcitation widths and via a dimensionality approach. The enhancement of the E1 transitions is the most striking

  17. Numerical simulation of distorted crystal Darwin width

    International Nuclear Information System (INIS)

    Wang Li; Xu Zhongmin; Wang Naxiu

    2012-01-01

    A new numerical simulation method according to distorted crystal optical theory was used to predict the direct-cooling crystal monochromator optical properties(crystal Darwin width) in this study. The finite element analysis software was used to calculate the deformed displacements of DCM crystal and to get the local reciprocal lattice vector of distorted crystal. The broadening of direct-cooling crystal Darwin width in meridional direction was estimated at 4.12 μrad. The result agrees well with the experimental data of 5 μrad, while it was 3.89 μrad by traditional calculation method of root mean square (RMS) of the slope error in the center line of footprint. The new method provides important theoretical support for designing and processing of monochromator crystal for synchrotron radiation beamline. (authors)

  18. Calculation of excited vector meson electron widths using QCD sum rules

    International Nuclear Information System (INIS)

    Geshkenbein, B.V.

    1984-01-01

    The sum rules are suggested which allow one to calculate the electron widths of excited vector mesons of the PSI, UPSILON, rho meson family assuming the values of their masses to be known. The calculated values of the electron widths agree with experiment

  19. Real-time line-width measurements: a new feature for reticle inspection systems

    Science.gov (United States)

    Eran, Yair; Greenberg, Gad; Joseph, Amnon; Lustig, Cornel; Mizrahi, Eyal

    1997-07-01

    The significance of line width control in mask production has become greater with the lessening of defect size. There are two conventional methods used for controlling line widths dimensions which employed in the manufacturing of masks for sub micron devices. These two methods are the critical dimensions (CD) measurement and the detection of edge defects. Achieving reliable and accurate control of line width errors is one of the most challenging tasks in mask production. Neither of the two methods cited above (namely CD measurement and the detection of edge defects) guarantees the detection of line width errors with good sensitivity over the whole mask area. This stems from the fact that CD measurement provides only statistical data on the mask features whereas applying edge defect detection method checks defects on each edge by itself, and does not supply information on the combined result of error detection on two adjacent edges. For example, a combination of a small edge defect together with a CD non- uniformity which are both within the allowed tolerance, may yield a significant line width error, which will not be detected using the conventional methods (see figure 1). A new approach for the detection of line width errors which overcomes this difficulty is presented. Based on this approach, a new sensitive line width error detector was developed and added to Orbot's RT-8000 die-to-database reticle inspection system. This innovative detector operates continuously during the mask inspection process and scans (inspects) the entire area of the reticle for line width errors. The detection is based on a comparison of measured line width that are taken on both the design database and the scanned image of the reticle. In section 2, the motivation for developing this new detector is presented. The section covers an analysis of various defect types, which are difficult to detect using conventional edge detection methods or, alternatively, CD measurements. In section 3

  20. Statistical analysis of P-wave neutron reduced widths

    International Nuclear Information System (INIS)

    Joshi, G.C.; Agrawal, H.M.

    2000-01-01

    The fluctuations of the p-wave neutron reduced widths for fifty one nuclei have been analyzed with emphasis on recent measurements by a statistical procedure which is based on the method of maximum likelihood. It is shown that the p-wave neutron reduced widths of even-even nuclei fallow single channel Porter Thomas distribution (χ 2 -distribution with degree of freedom ν=1) for most of the cases where there are no intermediate structure. It is emphasized that the distribution in nuclei other than even-even may differ from a χ 2 -distribution with one degree of freedom. Possible explanation and significance of this deviation from ν=1 is given. (author)

  1. The ρ radiative decay width: A measurement at 200 GeV

    International Nuclear Information System (INIS)

    Capraro, L.; Levy, P.; Querrou, M.; Hecke, B. van; Verbeken, M.; Amendolia, S.R.; Batignani, G.; Bedeschi, A.; Bellamy, E.H.; Bertolucci, E.; Bosisio, L.; Bottigli, U.; Bradaschia, C.; Fidecaro, F.; Foa, L.; Focardi, E.; Giannetti, P.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Ristori, L.; Scribano, A.; Stefanini, A.; Tonelli, G.; Beck, G.A.; Bologna, G.; D'Ettorre Piazzoli, B.; Mannocchi, G.; Picchi, P.; Istituto Nazionale di Fisica Nucleare, Frascati; Budinich, M.; Liello, F.; Paver, N.; Rolandi, L.; Green, M.G.; March, P.V.; Landon, M.P.J.; Strong, J.A.; Tenchini, R.

    1987-01-01

    The ρ - radiative decay width has been measured by studying the production of ρ - via the Primakoff effect by 200 GeV incident π - on Cu and Pb targets. This width was obtained by fitting the measured dσ/dt for ρ production with the theoretical coherent differential cross section including both the electromagnetic and strong contributions. The measured radiative width value is 81±4±4 keV: it is consistent with the ratio Γ(ρ → πγ)/Γ(ω → πγ) ∝ 1/9 as expected from the vector dominance and the quark model. (orig.)

  2. Determination of the Ds0(2317) width with the PANDA detector

    International Nuclear Information System (INIS)

    Mertens, Marius Christian

    2012-01-01

    The D s0 *(2317) meson which was discovered at BaBar in 2003 has the interesting properties of a surprisingly narrow width and a mass just below the DK threshold. Different theoretical models try to explain the nature of its properties. A precise knowledge of the width is an important criterion to evaluate these models. However, only an upper limit of 3.8 MeV is known so far. A suitable method to determine the width of particles which are significantly narrower than the experimental mass resolution is to measure the production cross section as a function of the center of mass energy. The shape of this excitation function allows to deduce the width. At PANDA, the measurement of the production cross section will be possible in antiproton-proton collisions. The PANDA experiment at the future FAIR facility is designed to combine precisely adjustable beam momenta and high luminosities which make it an excellent tool for this kind of measurement. In the following we will describe the experimental procedure to carry out this measurement with the PANDA detector in order to achieve a resolution in the order of 0.1 MeV for the width of the D s0 *(2317).

  3. The effects of grip width on sticking region in bench press.

    Science.gov (United States)

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  4. On the maximal diphoton width

    CERN Document Server

    Salvio, Alberto; Strumia, Alessandro; Urbano, Alfredo

    2016-01-01

    Motivated by the 750 GeV diphoton excess found at LHC, we compute the maximal width into $\\gamma\\gamma$ that a neutral scalar can acquire through a loop of charged fermions or scalars as function of the maximal scale at which the theory holds, taking into account vacuum (meta)stability bounds. We show how an extra gauge symmetry can qualitatively weaken such bounds, and explore collider probes and connections with Dark Matter.

  5. Maxillary arch width and buccal corridor changes with Damon and conventional brackets: A retrospective analysis.

    Science.gov (United States)

    Shook, Corey; Kim, Sohyon Michelle; Burnheimer, John

    2016-07-01

    To evaluate the effect of Damon self-ligating and conventional bracket systems on buccal corridor widths and areas. A retrospective sample of consecutively treated patients using either conventional (CG, n  =  45) or Damon self-ligating (SL, n  =  39) brackets was analyzed to determine any differences in buccal corridor widths and areas both within and between groups. Pretreatment and posttreatment frontal photographs were transferred to Photoshop CC, standardized using intercanthal width, and linear and area measurements were performed with tools in Photoshop CC. Ratios were then calculated for statistical analysis. Relationships between arch widths and buccal corridors were also examined. There were no significant differences in the posttreatment intercanine or intermolar widths either within or between the CG and SL groups. There were no significant differences in any buccal corridor width or area measurement either within or between the CG and SL groups. There were strong correlations with the intercanine width and the corresponding buccal corridor smile width measurements. There was an inverse correlation with the buccal corridor area in relation to the canine and the total smile width. It is likely that posttreatment increases in arch width can be seen in patients treated with either a conventional bracket system or the Damon system. It is highly unlikely that there is any significant difference in buccal corridor width or area in patients treated with the Damon self-ligating system or a conventional bracket system.

  6. Optimum filters with time width constraints for liquid argon total-absorption detectors

    International Nuclear Information System (INIS)

    Gatti, E.; Radeka, V.

    1977-10-01

    Optimum filter responses are found for triangular current input pulses occurring in liquid argon ionization chambers used as total absorption detectors. The filters considered are subject to the following constraints: finite width of the output pulse having a prescribed ratio to the width of the triangular input current pulse and zero area of a bipolar antisymmetrical pulse or of a three lobe pulse, as required for high event rates. The feasibility of pulse shaping giving an output equal to, or shorter than, the input one is demonstrated. It is shown that the signal-to-noise ratio remains constant for the chamber interelectrode gap which gives an input pulse width (i.e., electron drift time) greater than one third of the required output pulse width

  7. Turbulent transport regimes and the scrape-off layer heat flux width

    Science.gov (United States)

    Myra, J. R.; D'Ippolito, D. A.; Russell, D. A.

    2015-04-01

    Understanding the responsible mechanisms and resulting scaling of the scrape-off layer (SOL) heat flux width is important for predicting viable operating regimes in future tokamaks and for seeking possible mitigation schemes. In this paper, we present a qualitative and conceptual framework for understanding various regimes of edge/SOL turbulence and the role of turbulent transport as the mechanism for establishing the SOL heat flux width. Relevant considerations include the type and spectral characteristics of underlying instabilities, the location of the gradient drive relative to the SOL, the nonlinear saturation mechanism, and the parallel heat transport regime. We find a heat flux width scaling with major radius R that is generally positive, consistent with the previous findings [Connor et al., Nucl. Fusion 39, 169 (1999)]. The possible relationship of turbulence mechanisms to the neoclassical orbit width or heuristic drift mechanism in core energy confinement regimes known as low (L) mode and high (H) mode is considered, together with implications for the future experiments.

  8. Turbulent transport regimes and the scrape-off layer heat flux width

    International Nuclear Information System (INIS)

    Myra, J. R.; D'Ippolito, D. A.; Russell, D. A.

    2015-01-01

    Understanding the responsible mechanisms and resulting scaling of the scrape-off layer (SOL) heat flux width is important for predicting viable operating regimes in future tokamaks and for seeking possible mitigation schemes. In this paper, we present a qualitative and conceptual framework for understanding various regimes of edge/SOL turbulence and the role of turbulent transport as the mechanism for establishing the SOL heat flux width. Relevant considerations include the type and spectral characteristics of underlying instabilities, the location of the gradient drive relative to the SOL, the nonlinear saturation mechanism, and the parallel heat transport regime. We find a heat flux width scaling with major radius R that is generally positive, consistent with the previous findings [Connor et al., Nucl. Fusion 39, 169 (1999)]. The possible relationship of turbulence mechanisms to the neoclassical orbit width or heuristic drift mechanism in core energy confinement regimes known as low (L) mode and high (H) mode is considered, together with implications for the future experiments

  9. The width of the giant dipole resonance at finite temperature

    International Nuclear Information System (INIS)

    Mau, N.V.

    1992-01-01

    A method is proposed to evaluate the effect of the change of the Fermi sea on the width of the giant dipole resonance at finite temperature. In a schematic model it is found that, indeed, in 208 Pb the width increases very sharply up to about T=4 MeV but shows a much weaker variation for higher temperature. (author) 26 refs., 7 figs., 2 tabs

  10. Relationship between width and length ratios of upper anterior teeth in young Chilean population.

    Directory of Open Access Journals (Sweden)

    Jorge Troncoso-Pazos

    2017-08-01

    Full Text Available Introduction: Knowledge about the size and proportion of upper anterior teeth allows dental rehabilitation taking into consideration the local parameters of a population. The aim of this research is to determine the width, length and the relationship between width and length of central incisor, lateral incisor and canine teeth in both sexes in young Chilean population. Methodology: A cross-sectional study was performed. Study subjects included 187 dentistry students from two Chilean cities (mean age 21.35±2.7 years, 52.9% men. The teeth width and height were measured and the width/height ratio was calculated. Differences in measurements according to sex was analyzed (p<0.05; STATA v.10.0. Results: The width and height of the teeth were statistically and proportionally larger in men (p<0.05. The width/height ratio of lateral and canine incisors was significantly higher in women (p<0.05. Conclusion: In a sample of young Chileans, upper anterior teeth were longer and wider in men. However, the width/height ratio of teeth was found to be significantly higher in women.

  11. The optimum choice of gate width for neutron coincidence counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S., E-mail: crofts@ornl.gov [Safeguards and Security Technology (SST), Global Nuclear Security Technology Divisions, PO Box 2008, Building 5700, MS-6166, Oak Ridge, TN 37831-6166 (United States); Henzlova, D.; Favalli, A.; Hauck, D.K.; Santi, P.A. [Safeguards Science and Technology Group (NEN-1), Nuclear Engineering and Nonproliferation Division, MS-E540, Los Alamos, NM 87545 (United States)

    2014-11-11

    In the measurement field of international nuclear safeguards, passive neutron coincidence counting is used to quantify the spontaneous fission rate of certain special nuclear materials. The shift register autocorrelation analysis method is the most commonly used approach. However, the Feynman-Y technique, which is more commonly applied in reactor noise analysis, provides an alternative means to extract the correlation information from a pulse train. In this work we consider how to select the optimum gate width for each of these two time-correlation analysis techniques. The optimum is considered to be that which gives the lowest fractional precision on the net doublets rate. Our theoretical approach is approximate but is instructional in terms of revealing the key functional dependence. We show that in both cases the same performance figure of merit applies so that common design criteria apply to the neutron detector head. Our prediction is that near optimal results, suitable for most practical applications, can be obtained from both techniques using a common gate width setting. The estimated precision is also comparable in the two cases. The theoretical expressions are tested experimentally using {sup 252}Cf spontaneous fission sources measured in two thermal well counters representative of the type in common use by international inspectorates. Fast accidental sampling was the favored method of acquiring the Feynman-Y data. Our experimental study confirmed the basic functional dependences predicted although experimental results when available are preferred. With an appropriate gate setting Feynman-Y analysis provides an alternative to shift register analysis for safeguards applications which is opening up new avenues of data collection and data reduction to explore.

  12. Analytical model for double split ring resonators with arbitrary ring width

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Jensen, Thomas; Krozer, Viktor

    2008-01-01

    For the first time, the analytical model for a double split ring resonator with unequal width rings is developed. The proposed models for the resonators with equal and unequal widths are based on an impedance matrix representation and provide the prediction of performance in a wide frequency range...

  13. Thermal conductivity engineering in width-modulated silicon nanowires and thermoelectric efficiency enhancement

    Science.gov (United States)

    Zianni, Xanthippi

    2018-03-01

    Width-modulated nanowires have been proposed as efficient thermoelectric materials. Here, the electron and phonon transport properties and the thermoelectric efficiency are discussed for dimensions above the quantum confinement regime. The thermal conductivity decreases dramatically in the presence of thin constrictions due to their ballistic thermal resistance. It shows a scaling behavior upon the width-modulation rate that allows for thermal conductivity engineering. The electron conductivity also decreases due to enhanced boundary scattering by the constrictions. The effect of boundary scattering is weaker for electrons than for phonons and the overall thermoelectric efficiency is enhanced. A ZT enhancement by a factor of 20-30 is predicted for width-modulated nanowires compared to bulk silicon. Our findings indicate that width-modulated nanostructures are promising for developing silicon nanostructures with high thermoelectric efficiency.

  14. Simple discretization method for autoionization widths. III. Molecules

    International Nuclear Information System (INIS)

    Macas, A.; Martn, F.; Riera, A.; Yanez, M.

    1987-01-01

    We apply a new method to calculate widths of two-electron Feshbach resonances, which was described in detail and applied to atomic systems in preceding articles (this issue), to molecular and quasimolecular autoionizing states. For simplicity in the programming effort, we restrict our calculations to the small-R region where one-centered expansions are sufficiently accurate to describe the wave functions. As test cases, positions and widths for the H 2 , He 2 /sup 2+/, HeH + , and LiHe/sup 3+/ resonances of lowest energy are computed for R<0.6 a.u. The advantage of using block-diagonalization techniques to define diabatic resonant states instead of generalizing the Feshbach formalism is pointed out

  15. Generation of ozone by Ns-width pulsed power

    International Nuclear Information System (INIS)

    Shimomura, Naoyuki; Wakimoto, Masaya; Shinke, Yosuke; Nagata, Masayoshi; Namihira, Takao; Akiyama, Hidenori

    2002-01-01

    The demand of ozone will be increasing for wholesome and environment-conscious sterilizations. The generation of ozone using the pulsed power discharge will apply electron accelerations around the head of streamer discharge principally. The breakdown in reactor often limits the efficient generation. Therefore, the pulse shape should be controlled for dimension of the reactor. It is clear that a pulse shortening is one of effective approaches. Pulsed power voltage with ns-width applies for ozone generation. The effects, on concentration and efficiency of generation, of pulse shape, repetition rate of pulse, flow rate of oxygen gas, and dimension and configuration of reactor, are discussed. The dimension and configuration of the reactor are optimized for the pulse width

  16. Comparison of the large muscle group widths of the pelvic limb in seven breeds of dogs.

    Science.gov (United States)

    Sabanci, Seyyid Said; Ocal, Mehmet Kamil

    2018-05-14

    Orthopaedic diseases are common in the pelvic limbs of dogs, and reference values for large muscle groups of the pelvic limb may aid in diagnosis such diseases. As such, the objective of this study was to compare the large muscle groups of the pelvic limb in seven breeds of dogs. A total of 126 dogs from different breeds were included, and the widths of the quadriceps, hamstring and gastrocnemius muscles were measured from images of the lateral radiographies. The width of the quadriceps was not different between the breeds, but the widths of the hamstring and gastrocnemius muscles were significantly different between the breeds. The widest hamstring and gastrocnemius muscles were seen in the Rottweilers and the Boxers, respectively. The narrowest hamstring and gastrocnemius muscles were seen in the Belgian Malinois and the Golden retrievers, respectively. All ratios between the measured muscles differed significantly between the breeds. Doberman pinschers and Belgian Malinois had the highest ratio of gastrocnemius width:hamstring width. Doberman pinschers had also the highest ratio of quadriceps width:hamstring width. German shepherds had the highest ratio of gastrocnemius width:quadriceps width. The lowest ratios of quadriceps width:hamstring width were determined in the German shepherds. The ratios of the muscle widths may be used as reference values to assess muscular atrophy or hypertrophy in cases of bilateral or unilateral orthopaedic diseases of the pelvic limbs. Further studies are required to determine the widths and ratios of the large muscle groups of the pelvic limbs in other dog breeds. © 2018 Blackwell Verlag GmbH.

  17. Study on conditional probability of surface rupture: effect of fault dip and width of seismogenic layer

    Science.gov (United States)

    Inoue, N.

    2017-12-01

    The conditional probability of surface ruptures is affected by various factors, such as shallow material properties, process of earthquakes, ground motions and so on. Toda (2013) pointed out difference of the conditional probability of strike and reverse fault by considering the fault dip and width of seismogenic layer. This study evaluated conditional probability of surface rupture based on following procedures. Fault geometry was determined from the randomly generated magnitude based on The Headquarters for Earthquake Research Promotion (2017) method. If the defined fault plane was not saturated in the assumed width of the seismogenic layer, the fault plane depth was randomly provided within the seismogenic layer. The logistic analysis was performed to two data sets: surface displacement calculated by dislocation methods (Wang et al., 2003) from the defined source fault, the depth of top of the defined source fault. The estimated conditional probability from surface displacement indicated higher probability of reverse faults than that of strike faults, and this result coincides to previous similar studies (i.e. Kagawa et al., 2004; Kataoka and Kusakabe, 2005). On the contrary, the probability estimated from the depth of the source fault indicated higher probability of thrust faults than that of strike and reverse faults, and this trend is similar to the conditional probability of PFDHA results (Youngs et al., 2003; Moss and Ross, 2011). The probability of combined simulated results of thrust and reverse also shows low probability. The worldwide compiled reverse fault data include low fault dip angle earthquake. On the other hand, in the case of Japanese reverse fault, there is possibility that the conditional probability of reverse faults with less low dip angle earthquake shows low probability and indicates similar probability of strike fault (i.e. Takao et al., 2013). In the future, numerical simulation by considering failure condition of surface by the source

  18. 75 FR 64507 - Taking and Importing Marine Mammals; Military Training Activities Conducted Within the Gulf of...

    Science.gov (United States)

    2010-10-19

    ... shallow and deep water. However, instead of using an explosive AN/SSQ-110A as an impulsive source for the... sensor and processing systems. In concept, the simplest active sonars emit omni-directional pulses... ASW acoustic processing and sonobuoy types that are deployed in pairs. The EER/IEER system's active...

  19. Factors determining variations in otolith microincrement width of demersal juvenile Baltic cod Gadus morhua

    DEFF Research Database (Denmark)

    Hüssy, Karin; Mosegaard, Henrik; Hinrichsen, H.H.

    2003-01-01

    by comparison with laboratory-reared individuals, and to investigate the factors determining variation in these increments. The different increment-width patterns were identified with a method based on the widths of consecutive increments. Otolith increment widths of juvenile cod were found to be highly...

  20. Modeling wildland fire containment with uncertain flame length and fireline width

    Science.gov (United States)

    Romain Mees; David Strauss; Richard Chase

    1993-01-01

    We describe a mathematical model for the probability that a fireline succeeds in containing a fire. The probability increases as the fireline width increases, and also as the fire's flame length decreases. More interestingly, uncertainties in width and flame length affect the computed containment probabilities, and can thus indirectly affect the optimum allocation...

  1. Strain localization band width evolution by electronic speckle pattern interferometry strain rate measurement

    Energy Technology Data Exchange (ETDEWEB)

    Guelorget, Bruno [Institut Charles Delaunay-LASMIS, Universite de technologie de Troyes, FRE CNRS 2848, 12 rue Marie Curie, B.P. 2060, 10010 Troyes Cedex (France)], E-mail: bruno.guelorget@utt.fr; Francois, Manuel; Montay, Guillaume [Institut Charles Delaunay-LASMIS, Universite de technologie de Troyes, FRE CNRS 2848, 12 rue Marie Curie, B.P. 2060, 10010 Troyes Cedex (France)

    2009-04-15

    In this paper, electronic speckle pattern interferometry strain rate measurements are used to quantify the width of the strain localization band, which occurs when a sheet specimen is submitted to tension. It is shown that the width of this band decreases with increasing strain. Just before fracture, this measured width is about five times wider than the shear band and the initial sheet thickness.

  2. Narrow widths of old and new resonances

    International Nuclear Information System (INIS)

    Pasupathy, J.

    1977-01-01

    A quantitative measure of the suppression factors involved in the pionic decays of mesons phi(1019) and f'(1514) as compared to their kaonic psi(3100) and psi(3700) decays are explained using the two different approaches, viz., the phenomenological S matrix approach and the field theoretical approach. The importance of the O-Z-I rule is brought out. The partial width GAMMA(phi → 3π) has been calculated using the dual model for the scattering kappa kappa(bar) → rhoπ. The effective coupling psi rho π is evaluated. The partial widths for psi → e + e - and psi → hadrons is calculated on a field theoretical approach. In conclusion, it appears that there are no serious objections to interpreting psi and psi' as cc - states. Most of their properties can be understood in a qualitative and in semi-quantitative way. (A.K.)

  3. Evaluation of arch width variations among different skeletal patterns in South Indian population.

    Science.gov (United States)

    Prasad, Mandava; Kannampallil, Senny Thomas; Talapaneni, Ashok Kumar; George, Suja Ani; Shetty, Sharath Kumar

    2013-01-01

    Anterior cranial base can be taken as a reference line (SN) to determine the steepness of mandibular plane. Subjects with high mandibular plane angle tend to have a long face and one with low MP-SN angle has a shorter face. This study was done to investigate if dental arch widths correlated with vertical facial types and if there are any differences in arch widths between untreated male and female adults in South Indian population. Lateral cephalogram and dental casts were obtained from 180 untreated South Indian adults (90 males and 90 females) above 18 year old with no cross bite, minimal crowding and spacing. The angle between the anterior cranial base and the mandibular plane was measured on lateral cephalogram of each patient. Dental casts were used to obtain comprehensive dental measurements including maxillary and mandibular inter canine, inter premolar and inter molar widths, as well as amount of crowding or spacing. The results showed that male arch widths were significantly larger than those of females (P population. The results obtained in our study when compared with studies done in other population groups showed that there is difference in inter arch widths according to ethnicity and race. It was concluded that the dental arch width is associated with gender, race and vertical facial morphology. Thus using individualized arch wires according to each patient's pre treatment arch form and width is suggested during orthodontic treatment.

  4. Scale orientated analysis of river width changes due to extreme flood hazards

    Directory of Open Access Journals (Sweden)

    G. Krapesch

    2011-08-01

    Full Text Available This paper analyses the morphological effects of extreme floods (recurrence interval >100 years and examines which parameters best describe the width changes due to erosion based on 5 affected alpine gravel bed rivers in Austria. The research was based on vertical aerial photos of the rivers before and after extreme floods, hydrodynamic numerical models and cross sectional measurements supported by LiDAR data of the rivers. Average width ratios (width after/before the flood were calculated and correlated with different hydraulic parameters (specific stream power, shear stress, flow area, specific discharge. Depending on the geomorphological boundary conditions of the different rivers, a mean width ratio between 1.12 (Lech River and 3.45 (Trisanna River was determined on the reach scale. The specific stream power (SSP best predicted the mean width ratios of the rivers especially on the reach scale and sub reach scale. On the local scale more parameters have to be considered to define the "minimum morphological spatial demand of rivers", which is a crucial parameter for addressing and managing flood hazards and should be used in hazard zone plans and spatial planning.

  5. E-plane Beam Width Reconfigurable Dipole Antenna with Tunable Parasitic Strip

    DEFF Research Database (Denmark)

    Zhang, Jin; Zhang, Shuai; Pedersen, Gert F.

    2018-01-01

    A 3-dB E-plane beam width (EPBW) reconfig- urable dipole antenna is proposed in this paper. By introducing a tunable C-shape strip, the EPBW of the dipole antenna can switch in three different modes: narrow, middle and wide. Three pairs of PIN diodes are used for controlling. The beam width tuning...

  6. Effects of Door Width and Human Body Size on Walking Speed

    Directory of Open Access Journals (Sweden)

    Jetthumrong Siwalee

    2016-01-01

    Full Text Available Door width is one of the important factors to concern in layout or facilities design because it affects directly to traffic speed and overall traffic time simultaneously. Nowadays, common assessment method is computer simulation which is still not realistic due to the unchanged speed of model while walking through a door. This research aims to study an effect of door width to individual walking speed. Sixty subjects participated in the experiment and performed task by walking through the door that is set the width as 40, 50, 60, 70, 80, 90 and 100 centimetres. The optical motion capture system was used to determine walking speed. The results showed that Fitts’ law was applied to the participants with high weight. Door width below 70 centimetres significantly affected to changing speed at 0-0.5 m. before the door. Additionally, human size also affected changing speed. The factors include shoulder breadth, weight and interaction between shoulder breadth and weight were found to be significant. These factors explained 54.2% of changing speed.

  7. Long-term summer sunshine/moisture stress reconstruction from tree-ring widths from Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    S. Poljanšek

    2013-01-01

    Full Text Available We present the first summer sunshine reconstruction from tree-ring data for the western part of the Balkan Peninsula. Summer sunshine is tightly connected with moisture stress in trees, because the moisture stress and therefore the width of annual tree-rings is under the influence of the direct and interactive effects of sunshine duration (temperature, precipitation, cloud cover and evapotranspiration. The reconstruction is based on a calibrated z-scored mean chronology, calculated from tree-ring width measurements from 7 representative black pine (Pinus nigra Arnold sites in Bosnia and Herzegovina (BiH. A combined regression and scaling approach was used for the reconstruction of the summer sunshine. We found a significant negative correlation (r = −0.54, p < 0.0001 with mean June–July sunshine hours from Osijek meteorological station (Croatia. The developed model was used for reconstruction of summer sunshine for the time period 1660–2010. We identified extreme summer events and compared them to available documentary historical sources of drought, volcanic eruptions and other reconstructions from the broader region. All extreme summers with low sunshine hours (1712, 1810, 1815, 1843, 1899 and 1966 are connected with volcanic eruptions.

  8. Optical track width measurements below 100 nm using artificial neural networks

    Science.gov (United States)

    Smith, R. J.; See, C. W.; Somekh, M. G.; Yacoot, A.; Choi, E.

    2005-12-01

    This paper discusses the feasibility of using artificial neural networks (ANNs), together with a high precision scanning optical profiler, to measure very fine track widths that are considerably below the conventional diffraction limit of a conventional optical microscope. The ANN is trained using optical profiles obtained from tracks of known widths, the network is then assessed by applying it to test profiles. The optical profiler is an ultra-stable common path scanning interferometer, which provides extremely precise surface measurements. Preliminary results, obtained with a 0.3 NA objective lens and a laser wavelength of 633 nm, show that the system is capable of measuring a 50 nm track width, with a standard deviation less than 4 nm.

  9. Characterizing the width of amphibian movements during postbreeding migration.

    Science.gov (United States)

    Coster, Stephanie S; Veysey Powell, Jessica S; Babbitt, Kimberly J

    2014-06-01

    Habitat linkages can help maintain connectivity of animal populations in developed landscapes. However, the lack of empirical data on the width of lateral movements (i.e., the zigzagging of individuals as they move from one point to point another) makes determining the width of such linkages challenging. We used radiotracking data from wood frogs (Lithobates sylvaticus) and spotted salamanders (Ambystoma maculatum) in a managed forest in Maine (U.S.A.) to characterize movement patterns of populations and thus inform planning for the width of wildlife corridors. For each individual, we calculated the polar coordinates of all locations, estimated the vector sum of the polar coordinates, and measured the distance from each location to the vector sum. By fitting a Gaussian distribution over a histogram of these distances, we created a population-level probability density function and estimated the 50th and 95th percentiles to determine the width of lateral movement as individuals progressed from the pond to upland habitat. For spotted salamanders 50% of lateral movements were ≤13 m wide and 95% of movements were ≤39 m wide. For wood frogs, 50% of lateral movements were ≤17 m wide and 95% of movements were ≤ 51 m wide. For both species, those individuals that traveled the farthest from the pond also displayed the greatest lateral movement. Our results serve as a foundation for spatially explicit conservation planning for pond-breeding amphibians in areas undergoing development. Our technique can also be applied to movement data from other taxa to aid in designing habitat linkages. © 2014 Society for Conservation Biology.

  10. An inter-hemispheric, statistical study of nightside spectral width distributions from coherent HF scatter radars

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    2002-12-01

    Full Text Available A statistical investigation of the Doppler spectral width parameter routinely observed by HF coherent radars has been conducted between the Northern and Southern Hemispheres for the nightside ionosphere. Data from the SuperDARN radars at Thykkvibær, Iceland and Syowa East, Antarctica have been employed for this purpose. Both radars frequently observe regions of high (>200 ms-1 spectral width polewards of low (<200 ms-1 spectral width. Three years of data from both radars have been analysed both for the spectral width and line of sight velocity. The pointing direction of these two radars is such that the flow reversal boundary may be estimated from the velocity data, and therefore, we have an estimate of the open/closed field line boundary location for comparison with the high spectral widths. Five key observations regarding the behaviour of the spectral width on the nightside have been made. These are (i the two radars observe similar characteristics on a statistical basis; (ii a latitudinal dependence related to magnetic local time is found in both hemispheres; (iii a seasonal dependence of the spectral width is observed by both radars, which shows a marked absence of latitudinal dependence during the summer months; (iv in general, the Syowa East spectral width tends to be larger than that from Iceland East, and (v the highest spectral widths seem to appear on both open and closed field lines. Points (i and (ii indicate that the cause of high spectral width is magnetospheric in origin. Point (iii suggests that either the propagation of the HF radio waves to regions of high spectral width or the generating mechanism(s for high spectral width is affected by solar illumination or other seasonal effects. Point (iv suggests that the radar beams from each of the radars are subject either to different instrumental or propagation effects, or different geophysical conditions due to their locations, although we suggest that this result is more likely to

  11. Level and width statistics for a decaying chaotic system

    International Nuclear Information System (INIS)

    Mizutori, S.; Zelevinsky, V.G.

    1993-01-01

    The random matrix ensemble of discretized effective non-hermitian hamiltonians is used for studying local correlations and fluctuations of energies and widths in a quantum system where intrinsic levels are coupled to the continuum via a common decay channel. With the use of analytical estimates and numerical simulations, generic properties of statistical observables are obtained for the regimes of weak and strong continuum coupling as well as for the transitional region. Typical signals of the transition (width collectivization, disappearance of level repulsion at small spacings and violation of uniformity along the energy axis) are discussed quantitatively. (orig.)

  12. Plume rise from multiple sources

    International Nuclear Information System (INIS)

    Briggs, G.A.

    1975-01-01

    A simple enhancement factor for plume rise from multiple sources is proposed and tested against plume-rise observations. For bent-over buoyant plumes, this results in the recommendation that multiple-source rise be calculated as [(N + S)/(1 + S)]/sup 1/3/ times the single-source rise, Δh 1 , where N is the number of sources and S = 6 (total width of source configuration/N/sup 1/3/ Δh 1 )/sup 3/2/. For calm conditions a crude but simple method is suggested for predicting the height of plume merger and subsequent behavior which is based on the geometry and velocity variations of a single buoyant plume. Finally, it is suggested that large clusters of buoyant sources might occasionally give rise to concentrated vortices either within the source configuration or just downwind of it

  13. A diffusive model for halo width growth during vertical displacement events

    International Nuclear Information System (INIS)

    Eidietis, N.W.; Humphreys, D.A.

    2011-01-01

    The electromagnetic loads produced by halo currents during vertical displacement events (VDEs) impose stringent requirements on the strength of ITER in-vessel components. A predictive understanding of halo current evolution is essential for ensuring the robust design of these components. A significant factor determining that evolution is the plasma resistance, which is a function of three quantities: the resistivities of the core and halo regions, and the halo region width. A diffusive model of halo width growth during VDEs has been developed, which provides one part of a physics basis for predictive halo current simulations. The diffusive model was motivated by DIII-D observations that VDEs with cold post-thermal quench plasma and a current decay time much faster than the vertical motion (type I VDE) possess much wider halo region widths than warmer plasma VDEs, where the current decay is much slower than the vertical motion (type II). A 2D finite element code is used to model the diffusion of toroidal halo current during selected type I and type II DIII-D VDEs. The model assumes a core plasma region within the last closed flux surface (LCFS) diffusing current into a halo plasma filling the vessel outside the LCFS. LCFS motion and plasma temperature are prescribed from experimental observations. The halo width evolution produced by this model compares favourably with experimental measurements of type I and type II toroidal halo current width evolution.

  14. A rapid technique for estimating the depth and width of a two-dimensional plate from self-potential data

    International Nuclear Information System (INIS)

    Mehanee, Salah; Smith, Paul D; Essa, Khalid S

    2011-01-01

    Rapid techniques for self-potential (SP) data interpretation are of prime importance in engineering and exploration geophysics. Parameters (e.g. depth, width) estimation of the ore bodies has also been of paramount concern in mineral prospecting. In many cases, it is useful to assume that the SP anomaly is due to an ore body of simple geometric shape and to use the data to determine its parameters. In light of this, we describe a rapid approach to determine the depth and horizontal width of a two-dimensional plate from the SP anomaly. The rationale behind the scheme proposed in this paper is that, unlike the two- (2D) and three-dimensional (3D) SP rigorous source current inversions, it does not demand a priori information about the subsurface resistivity distribution nor high computational resources. We apply the second-order moving average operator on the SP anomaly to remove the unwanted (regional) effect, represented by up to a third-order polynomial, using filters of successive window lengths. By defining a function F at a fixed window length (s) in terms of the filtered anomaly computed at two points symmetrically distributed about the origin point of the causative body, the depth (z) corresponding to each half-width (w) is estimated by solving a nonlinear equation in the form ξ(s, w, z) = 0. The estimated depths are then plotted against their corresponding half-widths on a graph representing a continuous curve for this window length. This procedure is then repeated for each available window length. The depth and half-width solution of the buried structure is read at the common intersection of these various curves. The improvement of this method over the published first-order moving average technique for SP data is demonstrated on a synthetic data set. It is then verified on noisy synthetic data, complicated structures and successfully applied to three field examples for mineral exploration and we have found that the estimated depth is in good agreement with

  15. Influence of MLC leaf width on biologically adapted IMRT plans

    Energy Technology Data Exchange (ETDEWEB)

    Roedal, Jan; Soevik, Aaste; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway)), E-mail: jan.rodal@radiumhospitalet.no

    2010-10-15

    Introduction. High resolution beam delivery may be required for optimal biology-guided adaptive therapy. In this work, we have studied the influence of multi leaf collimator (MLC) leaf widths on the treatment outcome following adapted IMRT of a hypoxic tumour. Material and methods. Dynamic contrast enhanced MR images of a dog with a spontaneous tumour in the nasal region were used to create a tentative hypoxia map following a previously published procedure. The hypoxia map was used as a basis for generating compartmental gross tumour volumes, which were utilised as planning structures in biologically adapted IMRT. Three different MLCs were employed in inverse treatment planning, with leaf widths of 2.5 mm, 5 mm and 10 mm. The number of treatment beams and the degree of step-and-shoot beam modulation were varied. By optimising the tumour control probability (TCP) function, optimal compartmental doses were derived and used as target doses in the inverse planning. Resulting IMRT dose distributions and dose volume histograms (DVHs) were exported and analysed, giving estimates of TCP and compartmental equivalent uniform doses (EUDs). The impact of patient setup accuracy was simulated. Results. The MLC with the smallest leaf width (2.5 mm) consistently gave the highest TCPs and compartmental EUDs, assuming no setup error. The difference between this MLC and the 5 mm MLC was rather small, while the MLC with 10 mm leaf width gave considerably lower TCPs. When including random and systematic setup errors, errors larger than 5 mm gave only small differences between the MLC types. For setup errors larger than 7 mm no differences were found between non-uniform and uniform dose distributions. Conclusions. Biologically adapted radiotherapy may require MLCs with leaf widths smaller than 10 mm. However, for a high probability of cure it is crucial that accurate patient setup is ensured.

  16. Adsorbed Organic Material and Its Control on Wettability

    DEFF Research Database (Denmark)

    Matthiesen, Jesper; Hassenkam, Tue; Bovet, Nicolas Emile

    2017-01-01

    salinity. Here we quantified the response of sandstone core plug material in its preserved state (i.e., after storage in kerosene) and after the same core plug material was treated with ethanol and ozone to remove adsorbed organic compounds. We used the chemical force microscopy (CFM) mode of atomic force...... surfaces in artificial seawater (ASW; 35,600 ppm) and in ASW diluted to ∼1,500 ppm (ASW-low). Both before and after the ethanol/ozone treatment, and for both the alkane and the carboxylate functionalized tips, the adhesion was lower in ASW diluted to ∼1,500 ppm than in ASW. For both alkane and carboxylate...... ethanol/ozone treatment, to be a result of the loss of the organic material that was originally adsorbed on these surfaces, which adds to the charge density and thereby to the salinity dependent EDL force. Investigating the same area on the same pore surface, before and after removal of the organic...

  17. The nose shape as a predictor of maxillary central and lateral incisor width.

    Science.gov (United States)

    Sülün, Tonguç; Ergin, Ugur; Tuncer, Necat

    2005-09-01

    One of the primary aspects of complete denture prosthodontics is determining the correct proportion for the maxillary central incisor width to the lateral incisor width. It has been suggested that the anatomy of the patient's nose is a reliable guide for deciding this ratio. The aim of this study was to test the hypothesis about the relationship between the shape of the nose and the proportion of the central incisor width (CIW) to the lateral incisor width (LIW). The CIW and LIW from a total of 138 subjects (73 males, 65 females) were measured intraorally. The interalar width (IAW) and the width of the root of the nose (WRN) were measured on standard photographs of the subjects. Spearman's rho test was used to analyze the correlation between the proportions of the CIW to the LIW and the IAW to the WRN. The Mann-Whitney Utest was applied to test for any possible gender differences. The IAW, the WRN, and the nose angle (NA) were statistically significantly wider in male subjects than in female subjects. The correlation between IAW/WRN, NA, and CIW/LIW was statistically significant only in female subjects. In the general population, the only statistically significant relationship was between CIW/LIW on the left side and IAW/WRN. Within the results of the IAW, WRN, and NA measurements, we suggest that males have wider, more triangular-shaped noses than females. The proportion of IAW to WRN seems to be a reliable guide for deciding the proportion of the maxillary central incisor width to the lateral incisor.

  18. Shunt PWM advanced var compensators based on voltage source inverters for Facts applications

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Pedro G; Misaka, Isamu; Watanabe, Edson H [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1994-12-31

    Increased attention has been given to improving power system operation. This paper presents modeling, analysis and design of reactive shunt power compensators based on PWM-Voltage Source Inverters (Pulse Width Modulation -Voltage Source Inverters). (Pulse Width Modulation - Voltage Source Inverters). The control algorithm is based on new concepts of instantaneous active and reactive power theory. The objective is to show that with a small capacitor in the side of a 3-phase PWM-VSI it is possible to synthesize a variable reactive (capacitive or inductive) device. Design procedures and experimental results are presented. The feasibility of this method was verified by digital simulations and measurements on a small scale model. (author) 9 refs., 12 figs.

  19. Estimates for the widths of weighted Sobolev classes

    International Nuclear Information System (INIS)

    Vasil'eva, Anastasia A

    2010-01-01

    Estimates for the Kolmogorov widths in the L q,v -metric of weighted Sobolev classes as well as for the approximation numbers of the corresponding embedding operators are found. Bibliography: 33 titles.

  20. The role of coral-associated bacterial communities in Australian Subtropical White Syndrome of Turbinaria mesenterina.

    Science.gov (United States)

    Godwin, Scott; Bent, Elizabeth; Borneman, James; Pereg, Lily

    2012-01-01

    Australian Subtropical White Syndrome (ASWS) is an infectious, temperature dependent disease of the subtropical coral Turbinaria mesenterina involving a hitherto unknown transmissible causative agent. This report describes significant changes in the coral associated bacterial community as the disease progresses from the apparently healthy tissue of ASWS affected coral colonies, to areas of the colony affected by ASWS lesions, to the dead coral skeleton exposed by ASWS. In an effort to better understand the potential roles of bacteria in the formation of disease lesions, the effect of antibacterials on the rate of lesion progression was tested, and both culture based and culture independent techniques were used to investigate the bacterial communities associated with colonies of T. mesenterina. Culture-independent analysis was performed using the Oligonucleotide Fingerprinting of Ribosomal Genes (OFRG) technique, which allowed a library of 8094 cloned bacterial 16S ribosomal genes to be analysed. Interestingly, the bacterial communities associated with both healthy and disease affected corals were very diverse and ASWS associated communities were not characterized by a single dominant organism. Treatment with antibacterials had a significant effect on the rate of progress of disease lesions (p = 0.006), suggesting that bacteria may play direct roles as the causative agents of ASWS. A number of potential aetiological agents of ASWS were identified in both the culture-based and culture-independent studies. In the culture-independent study an Alphaproteobacterium closely related to Roseovarius crassostreae, the apparent aetiological agent of juvenile oyster disease, was found to be significantly associated with disease lesions. In the culture-based study Vibrio harveyi was consistently associated with ASWS affected coral colonies and was not isolated from any healthy colonies. The differing results of the culture based and culture-independent studies highlight the

  1. The role of coral-associated bacterial communities in Australian Subtropical White Syndrome of Turbinaria mesenterina.

    Directory of Open Access Journals (Sweden)

    Scott Godwin

    Full Text Available Australian Subtropical White Syndrome (ASWS is an infectious, temperature dependent disease of the subtropical coral Turbinaria mesenterina involving a hitherto unknown transmissible causative agent. This report describes significant changes in the coral associated bacterial community as the disease progresses from the apparently healthy tissue of ASWS affected coral colonies, to areas of the colony affected by ASWS lesions, to the dead coral skeleton exposed by ASWS. In an effort to better understand the potential roles of bacteria in the formation of disease lesions, the effect of antibacterials on the rate of lesion progression was tested, and both culture based and culture independent techniques were used to investigate the bacterial communities associated with colonies of T. mesenterina. Culture-independent analysis was performed using the Oligonucleotide Fingerprinting of Ribosomal Genes (OFRG technique, which allowed a library of 8094 cloned bacterial 16S ribosomal genes to be analysed. Interestingly, the bacterial communities associated with both healthy and disease affected corals were very diverse and ASWS associated communities were not characterized by a single dominant organism. Treatment with antibacterials had a significant effect on the rate of progress of disease lesions (p = 0.006, suggesting that bacteria may play direct roles as the causative agents of ASWS. A number of potential aetiological agents of ASWS were identified in both the culture-based and culture-independent studies. In the culture-independent study an Alphaproteobacterium closely related to Roseovarius crassostreae, the apparent aetiological agent of juvenile oyster disease, was found to be significantly associated with disease lesions. In the culture-based study Vibrio harveyi was consistently associated with ASWS affected coral colonies and was not isolated from any healthy colonies. The differing results of the culture based and culture-independent studies

  2. The temperature dependence of the width of the giant-dipole resonance

    International Nuclear Information System (INIS)

    Ormand, W.E.; Bortignon, P.F.; Broglia, R.A.

    1996-01-01

    The giant-dipole resonance (GDR) in 120 Sn and 208 Pb is studied as a function of excitation energy, angular momentum, and intrinsic width within the context of the adiabatic model. Theoretical evaluations of the full-width-at-half-maximum (FWHM) for the GDR strength function are compared with recent experimental data and are found to be in good agreement. (orig.)

  3. Stark width regularities within spectral series of the lithium isoelectronic sequence

    Science.gov (United States)

    Tapalaga, Irinel; Trklja, Nora; Dojčinović, Ivan P.; Purić, Jagoš

    2018-03-01

    Stark width regularities within spectral series of the lithium isoelectronic sequence have been studied in an approach that includes both neutrals and ions. The influence of environmental conditions and certain atomic parameters on the Stark widths of spectral lines has been investigated. This study gives a simple model for the calculation of Stark broadening data for spectral lines within the lithium isoelectronic sequence. The proposed model requires fewer parameters than any other model. The obtained relations were used for predictions of Stark widths for transitions that have not yet been measured or calculated. In the framework of the present research, three algorithms for fast data processing have been made and they enable quality control and provide verification of the theoretically calculated results.

  4. Determination by transfer reaction of alpha widths in fluorine for astrophysical interest

    International Nuclear Information System (INIS)

    Oliveira Santos, F. de

    1995-04-01

    The nucleosynthesis of fluorine is not known. Several astrophysical models predict the alpha radiative capture onto N 15 as the main fluorine production reaction. In the expression of the reaction rate, one parameter is missing: the alpha width of the resonance on the E = 4.377 MeV level in fluorine. A direct measurement is excluded due to the very low cross-section expected. We have determined this alpha width using a transfer reaction followed by analyses with FR-DWBA (Finite Range Distorted Wave Born Approximation) in a simple cluster alpha model. This experiment was carried out with a Li 7 beam with E = 28 MeV onto a N 15 gas target. The 16 first levels were studied. Spectroscopic factors were extracted for most of them. Alpha widths for unbound levels were determined. Many alpha width were compared with known values from direct reaction and the differences lie within the uncertainty range (factor 2). The alpha width for the E = 4.377 MeV level was determined (Γ α = 1.5*10 -15 MeV), its value is about 60 times weaker than the used value. The influence of our new rate was studied in AGB (Asymptotic Giant Branch) stars during thermal pulses. In this model the alteration is sensitive. (author)

  5. A fast integrated discriminator with continuously variable width

    International Nuclear Information System (INIS)

    Borghesi, A.; Goggi, G.; Nardo, R.

    1976-01-01

    A simple dc-coupled discriminator with fast switching characteristics has been realized. Both input threshold and output width are continuously variable; the ECL design allows high speed and high density with ample fanout. (Auth.)

  6. Stochastic Mixed-Effects Parameters Bertalanffy Process, with Applications to Tree Crown Width Modeling

    Directory of Open Access Journals (Sweden)

    Petras Rupšys

    2015-01-01

    Full Text Available A stochastic modeling approach based on the Bertalanffy law gained interest due to its ability to produce more accurate results than the deterministic approaches. We examine tree crown width dynamic with the Bertalanffy type stochastic differential equation (SDE and mixed-effects parameters. In this study, we demonstrate how this simple model can be used to calculate predictions of crown width. We propose a parameter estimation method and computational guidelines. The primary goal of the study was to estimate the parameters by considering discrete sampling of the diameter at breast height and crown width and by using maximum likelihood procedure. Performance statistics for the crown width equation include statistical indexes and analysis of residuals. We use data provided by the Lithuanian National Forest Inventory from Scots pine trees to illustrate issues of our modeling technique. Comparison of the predicted crown width values of mixed-effects parameters model with those obtained using fixed-effects parameters model demonstrates the predictive power of the stochastic differential equations model with mixed-effects parameters. All results were implemented in a symbolic algebra system MAPLE.

  7. Effects of excitation spectral width on decay profile of weakly confined excitons

    International Nuclear Information System (INIS)

    Kojima, O.; Isu, T.; Ishi-Hayase, J.; Kanno, A.; Katouf, R.; Sasaki, M.; Tsuchiya, M.

    2008-01-01

    We report the effect due to a simultaneous excitation of several exciton states on the radiative decay profiles on the basis of the nonlocal response of weakly confined excitons in GaAs thin films. In the case of excitation of single exciton state, the transient grating signal has two decay components. The fast decay component comes from nonlocal response, and the long-lived component is attributed to free exciton decay. With an increase of excitation spectral width, the nonlocal component becomes small in comparison with the long-lived component, and disappears under irradiation of a femtosecond-pulse laser with broader spectral width. The transient grating spectra clearly indicates the contribution of the weakly confined excitons to the signal, and the exciton line width hardly changes by excitation spectral width. From these results, we concluded that the change of decay profile is attributed not to the many-body effect but to the effect of simultaneous excitation of several exciton states

  8. The CME Flare Arcade and the Width of the CME in the Outer Corona

    Science.gov (United States)

    Moore, Ron; Falconer, David; Sterling, Alphonse

    2008-01-01

    Moore, Sterling, & Suess (2007, ApJ, 668, 1221) present evidence that (1) a CME is typically a magnetic bubble, a low-beta gplasmoid with legs h having roughly the 3D shape of a light bulb, and (2) in the outer corona the CME plasmoid is in lateral pressure equilibrium with the ambient magnetic field. They present three CMEs observed by SOHO/LASCO, each from a very different source located near the limb. One of these CMEs came from a compact ejective eruption from a small part of a sunspot active region, another came from a large quiet-region filament eruption, and the third CME, an extremely large and fast one, was produced in tandem with an X20 flare arcade that was centered on a huge delta sunspot. Each of these CMEs had more or less the classic lightbulb silhouette and attained a constant heliocentric angular width in the outer corona. This indicates that the CME plasmoid attained lateral magnetic pressure balance with the ambient radial magnetic field in the outer corona. This lateral pressure balance, together with the standard scenario for CME production by the eruption of a sheared-core magnetic arcade, yields the following simple estimate of the strength B(sub Flare) of the magnetic field in the flare arcade produced together with the CME: B(sub Flare) 1.4(theta CME/theta Flare)sup 2 G, where theta (sub CME) is the heliocentric angular width of the CME plasmoid in the outer corona and theta (sub Flare) is the heliocentric angular width of the full-grown flare arcade. Conversely, theta (sub CME) approximately equal to (R(sub Sun)sup -1(phi(sub Flare)/1.4)sup 1/2 radians, where Flare is the magnetic flux covered by the full-grown flare arcade. In addition to presenting the three CMEs of Moore, Sterling, & Suess (2007) and their agreement with this relation between CME and Flare, we present a further empirical test of this relation. For CMEs that erupt from active regions, the co-produced flare arcade seldom if ever covers the entire active region: if AR is

  9. Stark widths regularities within spectral series of sodium isoelectronic sequence

    Science.gov (United States)

    Trklja, Nora; Tapalaga, Irinel; Dojčinović, Ivan P.; Purić, Jagoš

    2018-02-01

    Stark widths within spectral series of sodium isoelectronic sequence have been studied. This is a unique approach that includes both neutrals and ions. Two levels of problem are considered: if the required atomic parameters are known, Stark widths can be calculated by some of the known methods (in present paper modified semiempirical formula has been used), but if there is a lack of parameters, regularities enable determination of Stark broadening data. In the framework of regularity research, Stark broadening dependence on environmental conditions and certain atomic parameters has been investigated. The aim of this work is to give a simple model, with minimum of required parameters, which can be used for calculation of Stark broadening data for any chosen transitions within sodium like emitters. Obtained relations were used for predictions of Stark widths for transitions that have not been measured or calculated yet. This system enables fast data processing by using of proposed theoretical model and it provides quality control and verification of obtained results.

  10. Interface width effect on the classical Rayleigh-Taylor instability in the weakly nonlinear regime

    International Nuclear Information System (INIS)

    Wang, L. F.; Ye, W. H.; Li, Y. J.

    2010-01-01

    In this paper, the interface width effects (i.e., the density gradient effects or the density transition layer effects) on the Rayleigh-Taylor instability (RTI) in the weakly nonlinear (WN) regime are investigated by numerical simulation (NS). It is found that the interface width effects dramatically influence the linear growth rate in the linear growth regime and the mode coupling process in the WN growth regime. First, the interface width effects decrease the linear growth rate of the RTI, particularly for the short perturbation wavelengths. Second, the interface width effects suppress (reduce) the third-order feedback to the fundamental mode, which induces the nonlinear saturation amplitude (NSA) to exceed the classical prediction, 0.1λ. The wider the density transition layer is, the larger the NSA is. The NSA in our NS can reach a half of its perturbation wavelength. Finally, the interface width effects suppress the generation and the growth of the second and the third harmonics. The ability to suppress the harmonics' growth increases with the interface width but decreases with the perturbation wavelength. On the whole, in the WN regime, the interface width effects stabilize the RTI, except for an enhancement of the NSA, which is expected to improve the understanding of the formation mechanism for the astrophysical jets, and for the jetlike long spikes in the high energy density physics.

  11. Variable Width Riparian Model Enhances Landscape and Watershed Condition

    Science.gov (United States)

    Abood, S. A.; Spencer, L.

    2017-12-01

    Riparian areas are ecotones that represent about 1% of USFS administered landscape and contribute to numerous valuable ecosystem functions such as wildlife habitat, stream water quality and flows, bank stability and protection against erosion, and values related to diversity, aesthetics and recreation. Riparian zones capture the transitional area between terrestrial and aquatic ecosystems with specific vegetation and soil characteristics which provide critical values/functions and are very responsive to changes in land management activities and uses. Two staff areas at the US Forest Service have coordinated on a two phase project to support the National Forests in their planning revision efforts and to address rangeland riparian business needs at the Forest Plan and Allotment Management Plan levels. The first part of the project will include a national fine scale (USGS HUC-12 digits watersheds) inventory of riparian areas on National Forest Service lands in western United States with riparian land cover, utilizing GIS capabilities and open source geospatial data. The second part of the project will include the application of riparian land cover change and assessment based on selected indicators to assess and monitor riparian areas on annual/5-year cycle basis.This approach recognizes the dynamic and transitional nature of riparian areas by accounting for hydrologic, geomorphic and vegetation data as inputs into the delineation process. The results suggest that incorporating functional variable width riparian mapping within watershed management planning can improve riparian protection and restoration. The application of Riparian Buffer Delineation Model (RBDM) approach can provide the agency Watershed Condition Framework (WCF) with observed riparian area condition on an annual basis and on multiple scales. The use of this model to map moderate to low gradient systems of sufficient width in conjunction with an understanding of the influence of distinctive landscape

  12. Design and Simulation of Control Technique for Permanent Magnet Synchronous Motor Using Space Vector Pulse Width Modulation

    Science.gov (United States)

    Khan, Mansoor; Yong, Wang; Mustafa, Ehtasham

    2017-07-01

    After the rapid advancement in the field of power electronics devices and drives for last few decades, there are different kinds of Pulse Width Modulation techniques which have been brought to the market. The applications ranging from industrial appliances to military equipment including the home appliances. The vey common application for the PWM is three phase voltage source inverter, which is used to convert DC to AC in the homes to supply the power to the house in case electricity failure, usually named as Un-interrupted Power Supply. In this paper Space Vector Pulse Width Modulation techniques is discussed and analysed under the control technique named as Field Oriented Control. The working and implementation of this technique has been studied by implementing on the three phase bridge inverter. The technique is used to control the Permanente Magnet Synchronous Motor. The drive system is successfully implemented in MATLAB/Simulink using the mathematical equation and algorithm to achieve the satisfactory results. PI type of controller is used to tuned ers of the motothe parametr i.e. torque and current.

  13. Thermal Width for Heavy Quarkonium in the Static Limit

    International Nuclear Information System (INIS)

    Shi Chao-Yi; Zhu Jia-Qing; Ma Zhi-Lei; Li Yun-De

    2015-01-01

    The thermal widths for heavy quarkonia are calculated for both Coulomb gauge (CG) and Feynman gauge (FG), and the comparisons between these results with the hard thermal loop (HTL) approximation ones are illustrated. The dissociation temperatures of heavy quarkonia in thermal medium are also discussed for CG, FG and HTL cases. It is shown that the thermal widths, derived from the HTL approximation and used in many research studies, cause some errors in the practical calculations at the temperature range accessible in the present experiment, and the problem of gauge dependence cannot be avoided when the complete self energy is used in the derivation of potential. (paper)

  14. Assessing developmental toxicity of caffeine and sweeteners in medaka (Oryzias latipes)

    OpenAIRE

    Lee, Wenjau; Wang, Yun-Chi

    2015-01-01

    The use of artificial sweeteners (ASWs) has increased and become more widespread, and consequently ASWs have appeared in aquatic environments around the world. However, their safety to the health of humans and wildlife remains inconclusive. In this study, using medaka embryos (Oryzias latipes), we investigated developmental toxicity of aspartame (ASP) and saccharin (SAC). Since ASWs are often consumed with caffeine (CAF) and CAF with sucrose (SUC), we tested biological activities of these fou...

  15. Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width.

    Science.gov (United States)

    De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher

    2015-12-01

    Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width . We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates , which have bounded hierarchy width-regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers.

  16. Quark-mixing renormalization effects on the W-boson partial decay widths

    International Nuclear Information System (INIS)

    Almasy, A.A.; Kniehl, B.A.; Sirlin, A.

    2008-10-01

    We briefly review existing proposals for the renormalization of the Cabibbo- Kobayashi-Maskawa matrix and study their numerical effects on the W-boson partial decay widths. The differences between the decay widths predicted by the various renormalization schemes are generally negligible, while their deviations from the MS results are very small, except for W + → u anti b and W + →c anti b, where they reach approximately 4%. (orig.)

  17. Impact of Spectral Notch Width on Neurophysiological Plasticity and Clinical Effectiveness of the Tailor-Made Notched Music Training.

    Directory of Open Access Journals (Sweden)

    Robert Wunderlich

    Full Text Available Tinnitus, the ringing in the ears that is unrelated to any external source, causes a significant loss in quality of life, involving sleep disturbance and depression for 1 to 3% of the general population. While in the first place tinnitus may be triggered by damage to the inner ear cells, the neural generators of subjective tinnitus are located in central regions of the nervous system. A loss of lateral inhibition, tonotopical reorganization and a gain-increase in response to the sensory deprivation result in hypersensitivity and hyperactivity in certain regions of the auditory cortex. In the tailor-made notched music training (TMNMT patients listen to music from which the frequency spectrum of the tinnitus has been removed. This evokes strong lateral inhibition from neurons tuned to adjacent frequencies onto the neurons involved in the tinnitus percept. A reduction of tinnitus loudness and tinnitus-related neural activity was achieved with TMNMT in previous studies. As the effect of lateral inhibition depends on the bandwidth of the notch, in the current study we altered the notch width to find the most effective notch width for TMNMT. We compared 1-octave notch width with ½-octave and ¼-octave. Participants chose their favorite music for the training that included three month of two hours daily listening. The outcome was measured by means of standardized questionnaires and magnetoencephalography. We found a general reduction of tinnitus distress in all administered tinnitus questionnaires after the training. Additionally, tinnitus-related neural activity was reduced after the training. Nevertheless, notch width did not have an influence on the behavioral or neural effects of TMNMT. This could be due to a non-linear resolution of lateral inhibition in high frequencies.

  18. Temperature dependence of the in situ widths of a rotating condensate in one dimensional optical potential

    International Nuclear Information System (INIS)

    Hassan, Ahmed S.; Soliman, Shemi S.M.

    2016-01-01

    In this paper, a conventional method of quantum statistical mechanics is used to study the temperature dependence of the in situ widths of a rotating condensate bosons in 1D optical potential. We trace the experimentally accessible parameters for which the temperature dependence of the in situ widths becomes perceivable. The calculated results showed that the temperature dependence of the in situ widths is completely different from that of a rotating condensate or trapped bosons in the optical lattice separately. The z-width shows distinct behavior from x- and y-widths due to the rotation effect. The obtained results provide useful qualitative theoretical results for future Bose Einstein condensation experiments in such traps. - Highlights: • The temperature dependence of the in situ widths of a rotating condensate boson in 1D optical potential is investigated. • We trace the experimentally accessible parameters for which the in situ widths become perceivable. • The above mentioned parameters exhibit a characteristic rotation rate and optical potential depth dependence. • Characteristic dependence of the effective widths on temperature is investigated. • Our results provide useful qualitatively and quantitative theoretical results for experiments in various traps.

  19. Scaling of divertor heat flux profile widths in DIII-D

    International Nuclear Information System (INIS)

    Lasnier, C.J.; Makowski, M.A.; Boedo, J.A.; Allen, S.L.; Brooks, N.H.; Hill, D.N.; Leonard, A.W.; Watkins, J.G.; West, W.P.

    2011-01-01

    New scalings of the dependence of divertor heat flux peak and profile width, important parameters for the design of future large tokamaks, have been obtained from recent DIII-D experiments. We find the peak heat flux depends linearly on input power, decreases linearly with increasing density, and increases linearly with plasma current. The profile width has a weak dependence on input power, is independent of density up to the onset of detachment, and is inversely proportional to the plasma current. We compare these results with previously published scalings, and present mathematical expressions incorporating these results.

  20. Solar harvesting by a heterostructured cell with built-in variable width quantum wells

    Science.gov (United States)

    Brooks, W.; Wang, H.; Mil'shtein, S.

    2018-02-01

    We propose cascaded heterostructured p-i-n solar cells, where inside of the i-region is a set of Quantum Wells (QWs) with variable thicknesses to enhance absorption of different photonic energies and provide quick relaxation for high energy carriers. Our p-i-n heterostructure carries top p-type and bottom n-type 11.3 Å thick AlAs layers, which are doped by acceptors and donor densities up to 1019/cm3. The intrinsic region is divided into 10 segments where each segment carries ten QWs of the same width and the width of the QWs in each subsequent segment gradually increases. The top segment consists of 10 QWs with widths of 56.5Å, followed by a segment with 10 wider QWs with widths of 84.75Å, followed by increasing QW widths until the last segment has 10 QWs with widths of 565Å, bringing the total number of QWs to 100. The QW wall height is controlled by alternating AlAs and GaAs layers, where the AlAs layers are all 11.3Å thick, throughout the entire intrinsic region. Configuration of variable width QWs prescribes sets of energy levels which are suitable for absorption of a wide range of photon energies and will dissipate high electron-hole energies rapidly, reducing the heat load on the solar cell. We expect that the heating of the solar cell will be reduced by 8-11%, enhancing efficiency. The efficiency of the designed solar cell is 43.71%, the Fill Factor is 0.86, the density of short circuit current (ISC) will not exceed 338 A/m2 and the open circuit voltage (VOC) is 1.51V.

  1. Joint space width in dysplasia of the hip

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig; Søballe, K

    2005-01-01

    In a longitudinal case-control study, we followed 81 subjects with dysplasia of the hip and 136 control subjects without dysplasia for ten years assessing radiological evidence of degeneration of the hip at admission and follow-up. There were no cases of subluxation in the group with dysplasia....... Neither subjects with dysplasia nor controls had radiological signs of ongoing degenerative disease at admission. The primary radiological discriminator of degeneration of the hip was a change in the minimum joint space width over time. There were no significant differences between these with dysplasia...... and controls in regard to age, body mass index or occupational exposure to daily repeated lifting at admission.We found no significant differences in the reduction of the joint space width at follow-up between subjects with dysplasia and the control subjects nor in self-reported pain in the hip...

  2. Fleet Assistance and Support Team (FAST) Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The FAST team was established by PMA-264 for introduction of multistatic ASW systems into the Fleet.FAST provides Air ASW mission planning, tactics/tactical sensor...

  3. Differences in the H-mode pedestal width of temperature and density

    International Nuclear Information System (INIS)

    Schneider, P A; Wolfrum, E; Günter, S; Kurzan, B; Lackner, K; Zohm, H; Groebner, R J; Osborne, T H; Ferron, J R; Snyder, P B; Beurskens, M N A; Dunne, M G

    2012-01-01

    A pedestal database was built using data from type-I ELMy H-modes of ASDEX Upgrade, DIII-D and JET. ELM synchronized pedestal data were analysed with the two-line method. The two-line method is a bilinear fit which shows better reproducibility of pedestal parameters than a modified hyperbolic tangent fit. This was tested with simulated and experimental data. The influence of the equilibrium reconstruction on pedestal parameters was investigated with sophisticated reconstructions from CLISTE and EFIT including edge kinetic profiles. No systematic deviation between the codes could be observed. The flux coordinate system is influenced by machine size, poloidal field and plasma shape. This will change the representation of the width in different coordinates, in particular, the two normalized coordinates Ψ N and r/a show a very different dependence on the plasma shape. The scalings derived for the pedestal width, Δ, of all machines suggest a different scaling for the electron temperature and the electron density. Both cases show similar dependence with machine size, poloidal magnetic field and pedestal electron temperature and density. The influence of ion temperature and toroidal magnetic field is different on each of Δ T e and Δ n e . In dimensionless form the density pedestal width in Ψ N scales with ρ 0.6 i* , the temperature pedestal width with β p,ped 0.5 . Both widths also show a strong correlation with the plasma shape. The shape dependence originates from the coordinate transformation and is not visible in real space. The presented scalings predict that in ITER the temperature pedestal will be appreciably wider than the density pedestal. (paper)

  4. Influence of diffuse goiter on tracheal width

    International Nuclear Information System (INIS)

    Baik, Sung Mo; Shon, Hyung Sun; Kim, Choon Yul; Bahk, Yong Whee

    1980-01-01

    The radioisotopic scanning of the thyroid gland is well established method of demonstrating morphology of the thyroid gland and is used to measure the size, area and weight of thyroid gland. The purpose of this investigation is to observe the various effects of goiter to the regional trachea. Both radioisotopic scanning and roentgenogram were taken at the same time to evaluate size, area and weight of the thyroid glands, as well as to measure the width of soft tissue structure of the neck and the regional trachea in normal and goitrous patients. The clinical materials consisted of normal thyroid group for control (46 cases), diffuse simple goiter group (76 cases) and Graves' disease group (59 cases). The results were as follows; 1. The goiter causes some narrowing of the regional trachea to various degree which is not necessarily reflective of the size of goiter. 2. The goiter may increase the width of retrotracheal soft tissue space. 3. The lateral roentgenogram of the neck appear very useful in estimating the thyroid gland three dimensionally and the effect of goiter to the regional trachea

  5. Partial widths of boson resonances in the quark-gluon model of strong interactions

    International Nuclear Information System (INIS)

    Kaidalov, A.B.; Volkovitsky, P.E.

    1981-01-01

    The quark-gluon model of strong interactions based on the topological expansion and the string model ib used for the calculation of the partial widths of boson resonances in the channels with two pseudoscalar mesons. The partial widths of mesons with arbitrary spins lying on the vector and tensor Regge trajectories are expressed in terms of the only rho-meson width. The violation of SU(3) symmetry increases with the growth of the spin of the resonance. The theoretical predictions are in a good agreement with experimental data [ru

  6. Domain wall width of lithium niobate poled during growth

    CERN Document Server

    Brooks, R; Hole, D E; Callejo, D; Bermudez, V; Diéguez, E

    2003-01-01

    Good quality crystals of periodically poled lithium niobate can be generated directly during growth. However, the temperature gradients at the zone boundaries define the width of the regions where the polarity is reversed. Hence, the region influenced the domain transition may be a significant fraction of the overall poling period for material poled during growth. Evidence for the scale of this feature is reported both by chemical etching and by the less common method of ion beam luminescence and the 'domain wall' width approximately 1 mu m for these analyses. The influence of the reversal region may differ for alternative techniques but the relevance to device design for second harmonic generation is noted.

  7. Ionospheric propagation effects on spectral widths measured by SuperDARN HF radars

    Directory of Open Access Journals (Sweden)

    X. Vallières

    2004-06-01

    Full Text Available SuperDARN HF radars provide a global survey of the large-scale convection transversely to the Earth's magnetic field in the high-latitude ionosphere. In addition to the mean plasma velocity, this network also provides measurements of spectral widths which are related to the level of turbulence of the sounded plasma. There is an increasing interest in using spectral widths in geophysical studies, since they are used to monitor the footprints of several magnetospheric regions. In the present paper, we show the effect of radio wave propagation through a typical turbulent ionosphere on spectral widths measured by SuperDARN radars. This effect has already been evidenced experimentally in a previous paper. Here, we model the effects of meso-scale structures on a radar wave front and study their impact on a typical measurement. Numerical simulations reproduce the effect evidenced experimentally and show the role of meso-scale structures (1-10km in the systematic bias that affects spectral width values. As in experimental data, this effect is shown to be increasing with decreasing radar frequency.

  8. Ionospheric propagation effects on spectral widths measured by SuperDARN HF radars

    Directory of Open Access Journals (Sweden)

    X. Vallières

    2004-06-01

    Full Text Available SuperDARN HF radars provide a global survey of the large-scale convection transversely to the Earth's magnetic field in the high-latitude ionosphere. In addition to the mean plasma velocity, this network also provides measurements of spectral widths which are related to the level of turbulence of the sounded plasma. There is an increasing interest in using spectral widths in geophysical studies, since they are used to monitor the footprints of several magnetospheric regions. In the present paper, we show the effect of radio wave propagation through a typical turbulent ionosphere on spectral widths measured by SuperDARN radars. This effect has already been evidenced experimentally in a previous paper. Here, we model the effects of meso-scale structures on a radar wave front and study their impact on a typical measurement. Numerical simulations reproduce the effect evidenced experimentally and show the role of meso-scale structures (1-10km in the systematic bias that affects spectral width values. As in experimental data, this effect is shown to be increasing with decreasing radar frequency.

  9. Influence of Gate Dielectrics, Electrodes and Channel Width on OFET Characteristics

    International Nuclear Information System (INIS)

    Liyana, V P; Stephania, A M; Shiju, K; Predeep, P

    2015-01-01

    Organic Field Effect Transistors (OFET) possess wide applications in large area electronics owing to their attractive features like easy fabrication process, light weight, flexibility, cost effectiveness etc. But instability, high operational voltages and low carrier mobility act as inhibitors to commercialization of OFETs and various approaches were tried on a regular basis so as to make it viable. In this work, Poly 3-hexylthiophene-2,5diyl (P3HT) based OFETs with bottom-contact top-gate configuration using Poly vinyl alcohol (PVA) and Poly (methyl methacrylate) (PMMA) as gate dielectrics, aluminium and copper as source-drain electrodes are investigated. An effort is made to compare the effect of these dielectric materials and electrodes on the performance of OFET. Also, an attempt has been made to optimize the channel width of the device. These devices are characterised with mobility (μ), threshold voltage (V T ), on-off ratio (I on /I off ) and their comparative analysis is reported. (paper)

  10. Influence of Gate Dielectrics, Electrodes and Channel Width on OFET Characteristics

    Science.gov (United States)

    Liyana, V. P.; Stephania, A. M.; Shiju, K.; Predeep, P.

    2015-06-01

    Organic Field Effect Transistors (OFET) possess wide applications in large area electronics owing to their attractive features like easy fabrication process, light weight, flexibility, cost effectiveness etc. But instability, high operational voltages and low carrier mobility act as inhibitors to commercialization of OFETs and various approaches were tried on a regular basis so as to make it viable. In this work, Poly 3-hexylthiophene-2,5diyl (P3HT) based OFETs with bottom-contact top-gate configuration using Poly vinyl alcohol (PVA) and Poly (methyl methacrylate) (PMMA) as gate dielectrics, aluminium and copper as source-drain electrodes are investigated. An effort is made to compare the effect of these dielectric materials and electrodes on the performance of OFET. Also, an attempt has been made to optimize the channel width of the device. These devices are characterised with mobility (μ), threshold voltage (VT), on-off ratio (Ion/Ioff) and their comparative analysis is reported.

  11. Electrodynamics of finite width guideway maglev systems in an integral equation formulation

    Energy Technology Data Exchange (ETDEWEB)

    Urankar, L [Siemens A.G., Erlangen (Germany, F.R.). Forschungslaboratorium

    1979-01-01

    A completely general, system-independent integral equation for the eddy current density is used to study the electrodynamics of finite guideway repulsive magleydsymaglev systems. For the first time a comparison of the transverse force measurements on a large-scale prototype vehicle (EET) with the theory is presented. The lateral displacement of the excitation magnet produces destabilizing transverse forces. The finite width of the guideway reduces the lift and increases the specific losses. The consequence is that for a given magnet width an adequate guideway overhang beyond the magnet width must be provided, so as not to suffer loss in the lift due to transverse edge effects and keep the lateral destabilizing force small.

  12. Predictors of the peak width for networks with exponential links

    Science.gov (United States)

    Troutman, B.M.; Karlinger, M.R.

    1989-01-01

    We investigate optimal predictors of the peak (S) and distance to peak (T) of the width function of drainage networks under the assumption that the networks are topologically random with independent and exponentially distributed link lengths. Analytical results are derived using the fact that, under these assumptions, the width function is a homogeneous Markov birth-death process. In particular, exact expressions are derived for the asymptotic conditional expectations of S and T given network magnitude N and given mainstream length H. In addition, a simulation study is performed to examine various predictors of S and T, including N, H, and basin morphometric properties; non-asymptotic conditional expectations and variances are estimated. The best single predictor of S is N, of T is H, and of the scaled peak (S divided by the area under the width function) is H. Finally, expressions tested on a set of drainage basins from the state of Wyoming perform reasonably well in predicting S and T despite probable violations of the original assumptions. ?? 1989 Springer-Verlag.

  13. Ridge Width Correlations between Inked Prints and Powdered Latent Fingerprints.

    Science.gov (United States)

    De Alcaraz-Fossoul, Josep; Barrot-Feixat, Carme; Zapico, Sara C; Mancenido, Michelle; Broatch, Jennifer; Roberts, Katherine A; Carreras-Marin, Clara; Tasker, Jack

    2017-10-03

    A methodology to estimate the time of latent fingerprint deposition would be of great value to law enforcement and courts. It has been observed that ridge topography changes as latent prints age, including the widths of ridges that could be measured as a function of time. Crime suspects are commonly identified using fingerprint databases that contain reference inked tenprints (flat and rolled impressions). These can be of interest in aging studies as they provide baseline information relating to the original (nonaged) ridges' widths. In practice, the age of latent fingerprints could be estimated following a comparison process between the evidentiary aged print and the corresponding reference inked print. The present article explores possible correlations between inked and fresh latent fingerprints deposited on different substrates and visualized with TiO 2 . The results indicate that the ridge width of flat inked prints is most similar to fresh latent fingerprints , and these should be used as the comparison standard for future aging studies. © 2017 American Academy of Forensic Sciences.

  14. Ultrasound-Guided Laryngeal Air Column Width Difference as a New Predictor for Postextubation Stridor in Children.

    Science.gov (United States)

    El Amrousy, Doaa; Elkashlan, Mohamed; Elshmaa, Nagat; Ragab, Ahmed

    2018-03-01

    To assess the efficacy of ultrasound-guided laryngeal air column width difference in predicting postextubation stridor in children. Prospective observational study. Single, tertiary care pediatric hospital. This study was carried out at PICU and surgical ICU, Tanta University Hospital on 400 ventilated children between January 2015 and May 2017. Patients who received mechanical ventilation and met criteria for a weaning trial were included. Laryngeal ultrasound and cuff leak test. Ultrasound-guided laryngeal air column width and cuff leak test were measured before extubation. Laryngeal air column width is the width of air between the vocal cords seen by laryngeal ultrasonography. Laryngeal air column width difference is the width difference of air column passed through vocal cords with the balloon cuff inflated and deflated. Three-hundred fifty six patients (89%) had no postextubation stridor, whereas 44 patients (11%) developed postextubation stridor. Postextubation stridor was associated with younger age, less weight, female gender, prolonged duration of intubation, and ICU stay (p column width difference and cuff leak test showed significant decrease (p column width difference at cutoff point of less than 0.8 mm gave a sensitivity of 93%, specificity of 86%, and accuracy of 91%, whereas cuff leak test at less than 11% yielded a sensitivity of (61%), specificity of (53%), and accuracy of (59%) for predicting postextubation stridor. Laryngeal air column width difference measurement may serve as a simple reliable noninvasive method for predicting postextubation stridor in children.

  15. Ultrafast electron diffraction using an ultracold source

    Directory of Open Access Journals (Sweden)

    M. W. van Mourik

    2014-05-01

    Full Text Available The study of structural dynamics of complex macromolecular crystals using electrons requires bunches of sufficient coherence and charge. We present diffraction patterns from graphite, obtained with bunches from an ultracold electron source, based on femtosecond near-threshold photoionization of a laser-cooled atomic gas. By varying the photoionization wavelength, we change the effective source temperature from 300 K to 10 K, resulting in a concomitant change in the width of the diffraction peaks, which is consistent with independently measured source parameters. This constitutes a direct measurement of the beam coherence of this ultracold source and confirms its suitability for protein crystal diffraction.

  16. Changes in step-width during dual-task walking predicts falls.

    Science.gov (United States)

    Nordin, E; Moe-Nilssen, R; Ramnemark, A; Lundin-Olsson, L

    2010-05-01

    The aim was to evaluate whether gait pattern changes between single- and dual-task conditions were associated with risk of falling in older people. Dual-task cost (DTC) of 230 community living, physically independent people, 75 years or older, was determined with an electronic walkway. Participants were followed up each month for 1 year to record falls. Mean and variability measures of gait characteristics for 5 dual-task conditions were compared to single-task walking for each participant. Almost half (48%) of the participants fell at least once during follow-up. Risk of falling increased in individuals where DTC for performing a subtraction task demonstrated change in mean step-width compared to single-task walking. Risk of falling decreased in individuals where DTC for carrying a cup and saucer demonstrated change compared to single-task walking in mean step-width, mean step-time, and step-length variability. Degree of change in gait characteristics related to a change in risk of falling differed between measures. Prognostic guidance for fall risk was found for the above DTCs in mean step-width with a negative likelihood ratio of 0.5 and a positive likelihood ratio of 2.3, respectively. Findings suggest that changes in step-width, step-time, and step-length with dual tasking may be related to future risk of falling. Depending on the nature of the second task, DTC may indicate either an increased risk of falling, or a protective strategy to avoid falling. Copyright 2010. Published by Elsevier B.V.

  17. A Direct Measurement of the $W$ Decay Width

    Energy Technology Data Exchange (ETDEWEB)

    Vine, Troy [Univ. of College, London (United Kingdom)

    2008-08-01

    A direct measurement of the W boson total decay width is presented in proton-antiproton collisions at √s = 1.96 TeV using data collected by the CDF II detector. The measurement is made by fitting a simulated signal to the tail of the transverse mass distribution in the electron and muon decay channels. An integrated luminosity of 350 pb-1 is used, collected between February 2002 and August 2004. Combining the results from the separate decay channels gives the decay width as 2.038 ± 0.072 GeV in agreement with the theoretical prediction of 2.093 ± 0.002 GeV. A system is presented for the management of detector calibrations using a relational database schema. A description of the implementation and monitoring of a procedure to provide general users with a simple interface to the complete set of calibrations is also given.

  18. Ground state energy and width of 7He from 8Li proton knockout

    International Nuclear Information System (INIS)

    Denby, D. H.; DeYoung, P. A.; Hall, C. C.; Baumann, T.; Bazin, D.; Spyrou, A.; Breitbach, E.; Howes, R.; Brown, J.; Frank, N.; Gade, A.; Mosby, S. M.; Peters, W. A.; Thoennessen, M.; Hinnefeld, J.; Hoffman, C. R.; Jenson, R. A.; Luther, B.; Olson, C. W.; Schiller, A.

    2008-01-01

    The ground state energy and width of 7 He has been measured with the Modular Neutron Array (MoNA) and superconducting dipole Sweeper magnet experimental setup at the National Superconducting Cyclotron Laboratory. 7 He was produced by proton knockout from a secondary 8 Li beam. The measured decay energy spectrum is compared to simulations based on Breit-Wigner line shape with an energy-dependent width for the resonant state. The energy of the ground state is found to be 400(10) keV with a full-width at half-maximum of 125( -15 +40 ) keV

  19. Bit rate and pulse width dependence of four-wave mixing of short optical pulses in semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Diez, S.; Mecozzi, A.; Mørk, Jesper

    1999-01-01

    We investigate the saturation properties of four-wave mixing of short optical pulses in a semiconductor optical amplifier. By varying the gain of the optical amplifier, we find a strong dependence of both conversion efficiency and signal-to-background ratio on pulse width and bit rate....... In particular, the signal-to-background ratio can be optimized for a specific amplifier gain. This behavior, which is coherently described in experiment and theory, is attributed to the dynamics of the amplified spontaneous emission, which is the main source of noise in a semiconductor optical amplifier....

  20. Histogram bin width selection for time-dependent Poisson processes

    International Nuclear Information System (INIS)

    Koyama, Shinsuke; Shinomoto, Shigeru

    2004-01-01

    In constructing a time histogram of the event sequences derived from a nonstationary point process, we wish to determine the bin width such that the mean squared error of the histogram from the underlying rate of occurrence is minimized. We find that the optimal bin widths obtained for a doubly stochastic Poisson process and a sinusoidally regulated Poisson process exhibit different scaling relations with respect to the number of sequences, time scale and amplitude of rate modulation, but both diverge under similar parametric conditions. This implies that under these conditions, no determination of the time-dependent rate can be made. We also apply the kernel method to these point processes, and find that the optimal kernels do not exhibit any critical phenomena, unlike the time histogram method

  1. Histogram bin width selection for time-dependent Poisson processes

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Shinsuke; Shinomoto, Shigeru [Department of Physics, Graduate School of Science, Kyoto University, Sakyo-ku, Kyoto 606-8502 (Japan)

    2004-07-23

    In constructing a time histogram of the event sequences derived from a nonstationary point process, we wish to determine the bin width such that the mean squared error of the histogram from the underlying rate of occurrence is minimized. We find that the optimal bin widths obtained for a doubly stochastic Poisson process and a sinusoidally regulated Poisson process exhibit different scaling relations with respect to the number of sequences, time scale and amplitude of rate modulation, but both diverge under similar parametric conditions. This implies that under these conditions, no determination of the time-dependent rate can be made. We also apply the kernel method to these point processes, and find that the optimal kernels do not exhibit any critical phenomena, unlike the time histogram method.

  2. The effect of buffer zone width on biodiversity

    DEFF Research Database (Denmark)

    Navntoft, Søren; Sigsgaard, Lene; Kristensen, Kristian Morten

    2012-01-01

    Field margin management for conservation purposes is a way to protect both functional biodiversity and biodiversity per se without considerable economical loss as field margins are less productive. However, the effect of width of the buffer zone on achievable biodiversity gains has received littl...

  3. Joint space width in dysplasia of the hip

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig; Søballe, K

    2005-01-01

    . Neither subjects with dysplasia nor controls had radiological signs of ongoing degenerative disease at admission. The primary radiological discriminator of degeneration of the hip was a change in the minimum joint space width over time. There were no significant differences between these with dysplasia...

  4. Antecedents of primary and secondary acute social withdrawal

    Directory of Open Access Journals (Sweden)

    Iryna Frankova

    2017-11-01

    Full Text Available Background. The phenomenon of acute social withdrawal (ASW is becoming more common and widespread nowadays and can be characterized by complete solitude/alienation from society for 6 months or longer. Previous studies of the ASW included patients with mental disorders and were focused on the psychopathological features of secondary ASW caused by depression, social phobia, or bulimia. Aim. To increase the effectiveness of acute social withdrawal differential diagnostics by determining the etiopathogenetic factors of its development and psychopathological features to improve further management of this condition. Materials and methods. At the Department of Psychosomatic Medicine and Psychotherapy of Bogomolets National Medical University 70 patients with ASW were examined: the first experimental group (EG1 - patients with mental disorders and ASW (n = 42, and the second (EG2 - a mentally healthy contingent with primary ASW (n = 28. Healthy people without ASW (n=56, control group, CG as well were examined. The following methods were used: Buss Durkee Hostility Inventory, Victim Behavior Questionnaire, Toronto Alexithymia Scale (TAS-26, Leongard-Schmishek Accentuated Personality Trait Questionnaire, Life Event Questionnaire (LEQ, Chaban Quality of Life Scale. Results. Comparing EG and CG regarding significance, there were determined several differences. The level of alexithymia in the EG was significantly higher than in the CG (p<0.005. The quality of life in the EG was significantly lower than in the CG (p<0.005.  According to the Leongard-Schmishek test in EG accentuated personality traits such cyclothymia, hyperthymia, dysthymia, anxiety (p<0.005, pedantic (p<0.05, demonstrativeness (p <0.1 were significantly higher than in the CG. According to the Buss-Durkee Hostility Inventory, such indicators as resentment (p<0.005, irritability (p<0.05, suspicion (p<0.05 and, as a consequence, an index of aggression (IA, (p<0.05 were significantly higher

  5. Neutron fluctuation analysis in a subcritical multiplying system with a stochastically pulsed poisson source

    International Nuclear Information System (INIS)

    Kostic, Lj.

    2003-01-01

    The influence of the stochastically pulsed Poisson source to the statistical properties of the subcritical multiplying system is analyzed in the paper. It is shown a strong dependence on the pulse period and pulse width of the source (author)

  6. Advanced Satellite Workstation - An integrated workstation environment for operational support of satellite system planning and analysis

    Science.gov (United States)

    Hamilton, Marvin J.; Sutton, Stewart A.

    A prototype integrated environment, the Advanced Satellite Workstation (ASW), which was developed and delivered for evaluation and operator feedback in an operational satellite control center, is described. The current ASW hardware consists of a Sun Workstation and Macintosh II Workstation connected via an ethernet Network Hardware and Software, Laser Disk System, Optical Storage System, and Telemetry Data File Interface. The central objective of ASW is to provide an intelligent decision support and training environment for operator/analysis of complex systems such as satellites. Compared to the many recent workstation implementations that incorporate graphical telemetry displays and expert systems, ASW provides a considerably broader look at intelligent, integrated environments for decision support, based on the premise that the central features of such an environment are intelligent data access and integrated toolsets.

  7. Constraints on dephasing widths and shifts in three-level quantum systems

    International Nuclear Information System (INIS)

    Berman, P.R.; O'Connell, Ross C.

    2005-01-01

    It is shown that the density matrix equations for a three-level quantum system interacting with external radiation fields can lead to negative populations if arbitrary dephasing rates and shifts are included in these equations. To guarantee non-negative populations, the equations themselves impose certain restrictions on the dephasing widths and shifts. The constraints on the widths are shown to be identical to those that can be derived from a model of Markovian dephasing events, independent of any atom-field interaction

  8. Sub-0.1 μm optical track width measurement

    Science.gov (United States)

    Smith, Richard J.; See, Chung W.; Somekh, Mike G.; Yacoot, Andrew

    2005-08-01

    In this paper, we will describe a technique that combines a common path scanning optical interferometer with artificial neural networks (ANN), to perform track width measurements that are significantly beyond the capability of conventional optical systems. Artificial neural networks have been used for many different applications. In the present case, ANNs are trained using profiles of known samples obtained from the scanning interferometer. They are then applied to tracks that have not previously been exposed to the networks. This paper will discuss the impacts of various ANN configurations, and the processing of the input signal on the training of the network. The profiles of the samples, which are used as the inputs to the ANNs, are obtained with a common path scanning optical interferometer. It provides extremely repeatable measurements, with very high signal to noise ratio, both are essential for the working of the ANNs. The characteristics of the system will be described. A number of samples with line widths ranging from 60nm-3μm have been measured to test the system. The system can measure line widths down to 60nm with a standard deviation of 3nm using optical wavelength of 633nm and a system numerical aperture of 0.3. These results will be presented in detail along with a discussion of the potential of this technique.

  9. Measurement of joint space width and erosion size

    NARCIS (Netherlands)

    Sharp, JI; van der Heijde, D; Angwin, J; Duryea, J; Moens, HJB; Jacobs, JWG; Maillefert, JF; Strand, CV

    2005-01-01

    Measurement of radiographic abnormalities in metric units has been reported by several investigators during the last 15 years. Measurement of joint space in large joints has been employed in a few trials to evaluate therapy in osteoarthritis. Measurement of joint space width in small joints has been

  10. Normal width of the anterior commissure of true vocal cord in Korea adults measured by helical CT

    International Nuclear Information System (INIS)

    Lim, Woo Young; Lim, Dong Hoon; Moon, Jang Il; Ko, Yong Seok; Byeon, Joo Nam; Oh, Jae Hee

    1998-01-01

    To evaluate the mean width of anterior commissure of true vocal cord in Korean adults by measuring its dimension on spiral CT scans. We reviewed the CT scans of 53 Korean adults(age range, 23-73years; mean age 39.2 years;M:F=3D41:12) without laryngeal disorders. Soiral CT scanning was performed around the anterior commissure with 1mm slice thickness and table incrementation for 15 seconds. The anteroposterior width of the anterior commissure was measured on CT scan where the true vocal cord and arytenoid, cricoid and thyroid cartilages were all present. We determined the mean width of the anterior commissure and whether there was a relationship between age and the width of the anterior commissure. The width of the anterior commissure was between 0.9mm and 2.3mm;mean width was 1.60±0.38mm(mean±SD). Using two SDs above the mean would have defined 2.36mm as the upper limit of normal width. Statistically, no significant correlation existed between the age and the width of the anterior commissure(p>0.05). An awareuess of the normal width range of the anterior commissure in Korean adults evaluated by spiral CT enhances the possibility of early detection of invasion of the anterior commissure by glottic cancer.=20

  11. Measurement of the mass and width of the W boson

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Anagnostou, G.; Anderson, K.J.; Asai, S.; Axen, D.; Bailey, I.; Barberio, E.; Barillari, T.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brown, Robert M.; Burckhart, H.J.; Campana, S.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herten, G.; Heuer, R.D.; Hill, J.C.; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krasznahorkay, A.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Meyer, Niels T.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rossi, A.M.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schorner-Sadenius, T.; Schroder, Matthias; Schumacher, M.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2006-01-01

    The mass and width of the W boson are measured using e+e- -> W+W- events from the data sample collected by the OPAL experiment at LEP at centre-of-mass energies between 170 GeV and 209 GeV. The mass (mw) and width (gw) are determined using direct reconstruction of the kinematics of W+W- -> qqbarlv and W+W- -> qqbarqqbar events. When combined with previous OPAL measurements using W+W- -> lvlv events and the dependence on mw of the WW production cross-section at threshold, the results are determined to be mw = 80.415 +- 0.042 +- 0.030 +- 0.009 GeV gw = 1.996 +- 0.096 +- 0.102 +- 0.003 GeV where the first error is statistical, the second systematic and the third due to uncertainties in the value of the LEP beam energy. By measuring mw with several different jet algorithms in the qqbarqqbar channel, a limit is also obtained on possible final-state interactions due to colour reconnection effects in W+W- -> qqbarqqbar events. The consistency of the results for the W mass and width with those inferred from other ele...

  12. Clinical Utility of Red Cell Distribution Width in Alcoholic and Non-alcoholic Liver Cirrhosis

    OpenAIRE

    Milić, Sandra; Mikolašević, Ivana; Radić, Mladen; Hauser, Goran; Štimac, Davor

    2011-01-01

    Red blood cell distribution width (RDW) is a measure of the variation of red blood cell width that is reported as a part of standard complete blood count. Red blood cell distribution width results are often used together with mean corpuscular volume (MCV) results to figure out mixed anemia. The aim of our study was to compare the values of RDW in alcoholic and non-alcoholic liver cirrhosis and to determine if RDW follows the severity of disease according to Child-Pugh score. We re...

  13. Antisubmarine Warfare (ASW) Lexicon

    Science.gov (United States)

    1990-01-01

    Communications Satellite CRT Cathode Ray Tube COMNAVSURFLANT Commander, CS Combat System; Computer Subsystem Naval Surface Force, U.S. Atlantic Fleet CSA Close...Sideband Low-Frequency Acoustic Vernier Analyzer LSD Large Screen Display LC Launch Control LSI Low Ship Impact 24 LSNSR Line-of-Bearing Sensor NCA

  14. Precision measurement of the mass and width of the W boson at CDF

    International Nuclear Information System (INIS)

    Malik, Sarah Alam

    2009-01-01

    A precision measurement of the mass and width of the W boson is presented. The W bosons are produced in proton antiproton collisions occurring at a centre of mass energy of 1.96 TeV at the Tevatron accelerator. The data used for the analyses is collected by the Collider Detector at Fermilab (CDF) and corresponds to an average integrated luminosity of 350 pb -1 for the W width analysis for the electron and muon channels and an average integrated luminosity of 2350 pb -1 for the W mass analysis. The mass and width of the W boson is extracted by fitting to the transverse mass distribution, with the peak of the distribution being most sensitive to the mass and the tail of the distribution sensitive to the width. The W width measurement in the electron and muon channels is combined to give a final result of 2032 ± 73 MeV. The systematic uncertainty on the W mass from the recoil of the W boson against the initial state gluon radiation is discussed. A systematic study of the recoil in Z → e + e - events where one electron is reconstructed in the central calorimeter and the other in the plug calorimeter and its effect on the W mass is presented for the first time in this thesis.

  15. Radio-frequency characteristic variation of interdigital capacitor having multilayer graphene of various widths

    Science.gov (United States)

    Lee, Hee-Jo; Hong, Young-Pyo

    2018-03-01

    In this paper, a radio-frequency circuit model of an interdigital capacitor (IDC) with a multilayer graphene (MLG) width variation is proposed. The circuit model with three sample configurations, i.e., a bare IDC, IDC-MLG with a width of 5 μm, and IDC-MLG with a width of 20 μm, is constructed via a fitted method based on the measured samples. The simulated results of the circuit model are validated through the RF characteristics, e.g., the capacitance and the self-resonance frequency, of the measured samples. From the circuit model, all samples show not only a similar capacitance behavior but also an identical self-resonance frequency of 10 GHz. Moreover, the R, L, and C values of MLG with a 5 μm width (MLG with a 20 μm width) alone are approximately 0.8 kΩ (0.5 kΩ), 0.5 nH (0.9 nH), and 0.3 pF (0.1 pF), respectively. As a result, we find that the simulated results are in good agreement with RF characteristics of the measured samples. In the future, we expect that the proposed circuit model of an IDC with MLG will offer assistance with performance predictions of diverse IDC-based 2D material applications, such as biosensors and gas sensors, as well as supercapacitors.

  16. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  17. Resolving single bubble sonoluminescence flask width

    OpenAIRE

    Arakeri, Vijay H

    1998-01-01

    Single bubble sonoluminescence (SBSL), first studied and observed by Gaitan et al., is the of light emission from a single gas bubble trapped at the pressure maximum of a resonant sound field in a liquid medium, generally water. One of the most striking aspects of SBSL was the estimated optical flash width being less than 50 picoseconds (ps)3; this upper estimate was based on the relative response of a SBSL flash in comparison to a 34 ps laser pulse using a microchannel platephotomultiplier ...

  18. Simple method for calculating island widths

    International Nuclear Information System (INIS)

    Cary, J.R.; Hanson, J.D.; Carreras, B.A.; Lynch, V.E.

    1989-01-01

    A simple method for calculating magnetic island widths has been developed. This method uses only information obtained from integrating along the closed field line at the island center. Thus, this method is computationally less intensive than the usual method of producing surfaces of section of sufficient detail to locate and resolve the island separatrix. This method has been implemented numerically and used to analyze the buss work islands of ATF. In this case the method proves to be accurate to at least within 30%. 7 refs

  19. Influence of Fracture Width on Sealability in High-Strength and Ultra-Low-Permeability Concrete in Seawater

    Directory of Open Access Journals (Sweden)

    Katsuhiko Kaneko

    2013-06-01

    Full Text Available For cementitious composites and materials, the sealing of fractures can occur in water by the precipitation of calcium compounds. In this study, the sealing behavior in a macro-fractured high-strength and ultra-low-permeability concrete (HSULPC specimen was investigated in simulated seawater using micro-focus X-ray computed tomography (CT. In particular, the influence of fracture width (0.10 and 0.25 mm on fracture sealing was investigated. Precipitation occurred mainly at the outermost parts of the fractured surface of the specimen for both fracture widths. While significant sealing was observed for the fracture width of 0.10 mm, sealing was not attained for the fracture width of 0.25 mm within the observation period (49 days. Examination of the sealed regions on the macro-fracture was performed using a three-dimensional image registration technique and applying image subtraction between the CT images of the HSULPC specimen before and after maintaining the specimen in simulated seawater. The temporal change of the sealing deposits for the fracture width of 0.10 mm was much larger than that for the fracture width of 0.25 mm. Therefore, it is concluded that the sealability of the fracture in the HSULPC is affected by the fracture width.

  20. Influence of Fracture Width on Sealability in High-Strength and Ultra-Low-Permeability Concrete in Seawater.

    Science.gov (United States)

    Fukuda, Daisuke; Nara, Yoshitaka; Hayashi, Daisuke; Ogawa, Hideo; Kaneko, Katsuhiko

    2013-06-25

    For cementitious composites and materials, the sealing of fractures can occur in water by the precipitation of calcium compounds. In this study, the sealing behavior in a macro-fractured high-strength and ultra-low-permeability concrete (HSULPC) specimen was investigated in simulated seawater using micro-focus X-ray computed tomography (CT). In particular, the influence of fracture width (0.10 and 0.25 mm) on fracture sealing was investigated. Precipitation occurred mainly at the outermost parts of the fractured surface of the specimen for both fracture widths. While significant sealing was observed for the fracture width of 0.10 mm, sealing was not attained for the fracture width of 0.25 mm within the observation period (49 days). Examination of the sealed regions on the macro-fracture was performed using a three-dimensional image registration technique and applying image subtraction between the CT images of the HSULPC specimen before and after maintaining the specimen in simulated seawater. The temporal change of the sealing deposits for the fracture width of 0.10 mm was much larger than that for the fracture width of 0.25 mm. Therefore, it is concluded that the sealability of the fracture in the HSULPC is affected by the fracture width.

  1. Clinical Utility of Ultrasound Measurements of Plantar Fascia Width and Cross-Sectional AreaA Novel Technique.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Rector, Michael

    2017-09-01

    We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability. Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements from one sonogram measured once and the mean of three measurements from three sonograms each measured once. Ultrasound measurements of PF width and CSA showed a mean of 18.6 ± 2.0 mm and 69.20 ± 13.6 mm 2 respectively. Intra-reliability within both raters showed an ICC > 0.84 for width and ICC > 0.92 for CSA as well as a SEM% and LOA% < 10% for both width and CSA. Inter-rater reliability showed an ICC of 0.82 for width and 0.87 for CSA as well as a SEM% and LOA% < 10% for width and a SEM% < 10% and LOA% < 20% for CSA. Relative and absolute reliability within and between raters were higher when using the mean of three sonographs compared to one sonograph. Using this novel technique, PF CSA and width may be determined reliably using measurements from one sonogram or the mean of three sonograms. Measurement of PF CSA and width in addition to already established thickness and echogenicity measurements provides additional information on structural properties of the PF for clinicians and researchers in healthy

  2. Anomalous electrical resistivity and Hall constant of Anderson lattice with finite f-band width

    International Nuclear Information System (INIS)

    Panwar, Sunil; Singh, Ishwar

    2002-01-01

    We study here an extension of the periodic Anderson model by considering finite f-band width. A variational method is used to study the temperature dependence of electronic transport properties of Anderson lattice for different values of the f-band width. The electrical resistivity ρ(T) and Hall constant R H (T) calculated show qualitatively the features experimentally observed in heavy fermion materials. We find that as f-band width increases, the low temperature peak in ρ(T) disappears, while the low-temperature peak in R H (T) becomes sharper. (author)

  3. Anti-Inflammatory Effects of Angelica sinensis (Oliv. Diels Water Extract on RAW 264.7 Induced with Lipopolysaccharide

    Directory of Open Access Journals (Sweden)

    Young-Jin Kim

    2018-05-01

    Full Text Available The dry root of Angelica sinensis (Oliv. Diels, also known as “female ginseng”, is a popular herbal drug amongst women, used to treat a variety of health issues and cardiovascular diseases. The aim of this study is to evaluate the detailed molecular mechanism for anti-inflammatory effects of Angelica sinensis root water extract (ASW. The anti-inflammatory effect of ASW on lipopolysaccharide (LPS-induced RAW 264.7 mouse macrophages was evaluated by the tetrazolium-based colorimetric assay (MTT, Griess reagent assay, multiplex cytokine assay, real time reverse transcription polymerase chain reaction (RT-PCR, and Fluo-4 calcium assay. ASW restored cell viability in RAW 264.7 at concentrations of up to 200 µg/mL. ASW showed notable anti-inflammatory effects. ASW exhibited IC50 = 954.3, 387.3, 191.7, 317.8, 1267.0, 347.0, 110.1, 573.6, 1171.0, 732.6, 980.8, 125.0, and 257.0 µg/mL for interleukin (IL-6, tumor necrosis factor (TNF-α, monocyte chemotactic activating factor (MCP-1, regulated on activation, normal T cell expressed and secreted (RANTES, granulocyte colony-stimulating factor (G-CSF, granulocyte macrophage colony-stimulating factor (GM-CSF, vascular endothelial growth factor (VEGF, lipopolysaccharide-induced CXC chemokine (LIX, macrophage inflammatory protein (MIP-1α, MIP-1β, MIP-2, IL-10, and intracellular calcium, respectively. Additionally, ASW inhibited the LPS-induced production of nitric oxide and the LPS-induced mRNA expression of CHOP (GADD153, Janus kinase 2 (JAK2, signal transducers and activators of transcription 1 (STAT1, first apoptosis signal receptor (FAS, and c-Fos, NOS2, and PTGS2 (COX2 in RAW 264.7 significantly (p < 0.05. Data suggest that ASW exerts an anti-inflammatory effect on LPS-induced RAW 264.7 via NO-bursting/calcium-mediated JAK-STAT pathway.

  4. Hydromorphodynamic effects of the width ratio and local tributary widening on discordant confluences

    Science.gov (United States)

    Guillén-Ludeña, S.; Franca, M. J.; Alegria, F.; Schleiss, A. J.; Cardoso, A. H.

    2017-09-01

    River training works performed in the last couple of centuries constrained the natural dynamics of channel networks in locations that include the confluences between tributaries and main channels. As a result, the dynamics of these confluences are currently characterized by homogeneous flow depths, flow velocities, and morphologic conditions, which are associated with impoverished ecosystems. The widening of river reaches is seen as a useful measure for river restoration, as it enhances the heterogeneity in flow depths, flow velocities, sediment transport, and bed substrates. The purpose of this study is to analyze the effects of local widening of the tributary mouth as well as the effects of the ratio between the width of the tributary and that of the main channel on the flow dynamics and bed morphology of river confluences. For that purpose, 12 experiments were conducted in a 70° laboratory confluence. In these experiments, three unit-discharge ratios were tested (qr = 0.37, 0.50, and 0.77) with two width ratios and two tributary configurations. The unit-discharge ratio is defined as the unit discharge in the tributary divided by that of the main channel, measured upstream of the confluence. The width ratio, which is defined as the width of the tributary divided by that of the main channel, was modified by changing the width of the main channel from 0.50 to 1.00 m (corresponding to Br = 0.30 and 0.15 respectively). The tributary configurations consisted of (i) a straight reach with a constant width (the so-called reference configuration) and (ii) a straight reach with a local widening at the downstream end (the so-called widened configuration). During the experiments, a uniform sediment mixture was continuously supplied to both channels. This experimental setup is novel among existing experimental studies on confluence dynamics, as it addresses new confluence configurations and includes a continuous sediment supply to both channels. The experiments were run

  5. Variation of martensite lath width and precipitate size during creep deformation in a 10Cr-Mo steel

    International Nuclear Information System (INIS)

    Kim, S. H.; Song, B. Z.; Lu, W. S.

    2001-01-01

    The relationship between creep deformation and microstructural changes in martensitic 10Cr-MoW steel has been studied. Transmission electron microscopy and image analyser were used to determine the variation of precipitates and martensite lath width size during creep deformation and aging. As precipitates are coarsened during creep deformation, dislocations become easy to move and the recovery proceeds rapidly. This leads to the growth of lath width. The average size of precipitates was linearly increased with creep time. On the other hand the growth rate of lath width is constant until tertiary creep, but the growth of lath width is accelerated during tertiary creep. It has been concluded that the growth behavior of lath width are consistent with creep deformation. Because the growth of lath width is controlled by the coarsening of precipitates it is important to form more stable precipitates in creep condition for improvement of creep properties of martensitie steel. Microstructure of martensitic steel is thermally very stable, so the size of precipitates and martensite lath width are hardly changed during aging

  6. A New Selective Harmonic Elimination Pulse- Width and Amplitude Modulation (SHEPWAM) for Drive Applications

    DEFF Research Database (Denmark)

    Ghoreishy, Hoda; Varjani, Ali Yazdian; Mohamadian, Mustafa

    2013-01-01

    Compared to the conventional selective harmonic elimination-pulse width modulation (SHE-PWM), the selective harmonic elimination-pulse width and amplitude modulation (SHE-PWAM) control strategy results in significant improvements in the performance of CHB inverters. This fact is due to considerin...

  7. On the relationship between finger width, velocity, and fluxes in thermohaline convection

    Science.gov (United States)

    Sreenivas, K. R.; Singh, O. P.; Srinivasan, J.

    2009-02-01

    Double-diffusive finger convection occurs in many natural processes. The theories for double-diffusive phenomena that exist at present consider systems with linear stratification in temperature and salinity. The double-diffusive systems with step change in salinity and temperature are, however, not amenable to simple stability analysis. Hence factors that control the width of the finger, velocity, and fluxes in systems that have step change in temperature and salinity have not been understood so far. In this paper we provide new physical insight regarding factors that influence finger convection in two-layer double-diffusive system through two-dimensional numerical simulations. Simulations have been carried out for density stability ratios (Rρ) from 1.5 to 10. For each density stability ratio, the thermal Rayleigh number (RaT) has been systematically varied from 7×103 to 7×108. Results from these simulations show how finger width, velocity, and flux ratios in finger convection are interrelated and the influence of governing parameters such as density stability ratio and the thermal Rayleigh number. The width of the incipient fingers at the time of onset of instability has been shown to vary as RaT-1/3. Velocity in the finger varies as RaT1/3/Rρ. Results from simulation agree with the scale analysis presented in the paper. Our results demonstrate that wide fingers have lower velocities and flux ratios compared to those in narrow fingers. This result contradicts present notions about the relation between finger width and flux ratio. A counterflow heat-exchanger analogy is used in understanding the dependence of flux ratio on finger width and velocity.

  8. Impact of Increased Football Field Width on Player High-Speed Collision Rate.

    Science.gov (United States)

    Joseph, Jacob R; Khalsa, Siri S; Smith, Brandon W; Park, Paul

    2017-07-01

    High-acceleration head impact is a known risk for mild traumatic brain injury (mTBI) based on studies using helmet accelerometry. In football, offensive and defensive players are at higher risk of mTBI due to increased speed of play. Other collision sport studies suggest that increased playing surface size may contribute to reductions in high-speed collisions. We hypothesized that wider football fields lead to a decreased rate of high-speed collisions. Computer football game simulation was developed using MATLAB. Four wide receivers were matched against 7 defensive players. Each offensive player was randomized to one of 5 typical routes on each play. The ball was thrown 3 seconds into play; ball flight time was 2 seconds. Defensive players were delayed 0.5 second before reacting to ball release. A high-speed collision was defined as the receiver converging with a defensive player within 0.5 second of catching the ball. The simulation counted high-speed collisions for 1 team/season (65 plays/game for 16 games/season = 1040 plays/season) averaged during 10 seasons, and was validated against existing data using standard field width (53.3 yards). Field width was increased in 1-yard intervals up to 58.3 yards. Using standard field width, 188 ± 4 high-speed collisions were seen per team per season (18% of plays). When field width increased by 3 yards, high-speed collision rate decreased to 135 ± 3 per team per season (28% decrease; P football field width can lead to substantial decline in high-speed collisions, with potential for reducing instances of mTBI in football players. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Bulimia nervosa: mood changes do have an impact on body width estimation.

    Science.gov (United States)

    Kulbartz-Klatt, Y J; Florin, I; Pook, M

    1999-09-01

    This study was designed to investigate the impact of mood changes on body width estimation in women with bulimia nervosa. A pre-post controlled experimental design was chosen. Mood changes were induced in 40 women with bulimia nervosa, 20 women with panic disorder and 40 women with no diagnosis of a psychological disorder. A combination of autobiographical memory method and music induction method was used to induce positive and negative mood, respectively. Before and after mood induction a video distorting technique was used for body width estimation. Induction of negative mood increased and induction of positive mood decreased the body width estimations of women with bulimia. Patients with panic disorder and 'healthy' controls did not show these changes after mood induction. The findings suggest that change in mood state rather than the more habitual mood quality are relevant for bulimic women's body perception.

  10. Changes in soft tissue nasal widths associated with rapid maxillary expansion in prepubertal and postpubertal subjects.

    Science.gov (United States)

    Johnson, Bret M; McNamara, James A; Bandeen, Roger L; Baccetti, Tiziano

    2010-11-01

    To evaluate changes in the soft tissue width of the nose induced by rapid maxillary expansion (RME). Data on greater alar cartilage (GAC) and alar base (AB) widths were compared with a normative sample within the same age range. This prospective study consisted of an RME sample of 79 patients treated with an RME protocol. Mean age at the start of RME treatment was 13.5 years; average duration of treatment was 6.7 months. Patients were grouped into prepubertal and postpubertal groups based on their cervical vertebral maturation (CVM) stage. AB and GAC widths were determined at three separate time points. The normative sample consisted of 437 orthodontically untreated whites, aged 10-16 years. A repeated measures analysis of variance (ANOVA) was used to determine group differences. In addition, independent sample t-tests were used to compare posttreatment nasal width values vs the untreated normative sample. Increases in AB and GAC widths of the nose in the RME sample were less than 1.5 mm. No significant differences were noted in width changes between the prepubertal and postpubertal subgroups. Comparisons of T3 values showed that on average nasal width increases were greater in the RME group than in untreated norms by 1.7 mm for the GAC measure (statistically significant), and by less than 1 mm for the AB measure. RME has no significant clinical effects on the widths of the apical base and the greater alar cartilage of the nose; no differences were observed between the two maturational subgroups.

  11. In-medium ϕ meson width extracted from proton-nucleus collisions

    Directory of Open Access Journals (Sweden)

    Roca L.

    2012-12-01

    Full Text Available The inclusive production of ϕ mesons at small angles in proton collisions with C, Cu, Ag, and Au targets has been measured at an incident energy of 2.83 GeV at the ANKE-COSY facility. The ϕ mesons were registered via the ϕ → K+K− decay. The momentum dependence of the nuclear transparency ratio, the in-medium ϕ width, and the differential cross section for ϕ production have been determined in the momentum region pϕ = 0.6 − 1.6 GeV/c. Comparison with different model calculations suggests a significant broadening of the in-medium ϕ width for normal nuclear density with evidence for a momentum dependence.

  12. The effect of the negative binomial distribution on the line-width of the micromaser cavity field

    International Nuclear Information System (INIS)

    Kremid, A. M.

    2009-01-01

    The influence of negative binomial distribution (NBD) on the line-width of the negative binomial distribution (NBD) on the line-width of the micromaser is considered. The threshold of the micromaser is shifted towards higher values of the pumping parameter q. Moreover the line-width exhibits sharp dips 'resonances' when the cavity temperature reduces to a very low value. These dips are very clear evidence for the occurrence of the so-called trapping states regime in the micromaser. This statistics prevents the appearance of these trapping states, namely by increasing the negative binomial parameter q these dips wash out and the line-width becomes more broadening. For small values of the parameter q the line-width at large values of q randomly oscillates around its transition line. As q becomes large this oscillatory behavior occurs at rarely values of q. (author)

  13. Effects of walking speed on the step-by-step control of step width.

    Science.gov (United States)

    Stimpson, Katy H; Heitkamp, Lauren N; Horne, Joscelyn S; Dean, Jesse C

    2018-02-08

    Young, healthy adults walking at typical preferred speeds use step-by-step adjustments of step width to appropriately redirect their center of mass motion and ensure mediolateral stability. However, it is presently unclear whether this control strategy is retained when walking at the slower speeds preferred by many clinical populations. We investigated whether the typical stabilization strategy is influenced by walking speed. Twelve young, neurologically intact participants walked on a treadmill at a range of prescribed speeds (0.2-1.2 m/s). The mediolateral stabilization strategy was quantified as the proportion of step width variance predicted by the mechanical state of the pelvis throughout a step (calculated as R 2 magnitude from a multiple linear regression). Our ability to accurately predict the upcoming step width increased over the course of a step. The strength of the relationship between step width and pelvis mechanics at the start of a step was reduced at slower speeds. However, these speed-dependent differences largely disappeared by the end of a step, other than at the slowest walking speed (0.2 m/s). These results suggest that mechanics-dependent adjustments in step width are a consistent component of healthy gait across speeds and contexts. However, slower walking speeds may ease this control by allowing mediolateral repositioning of the swing leg to occur later in a step, thus encouraging slower walking among clinical populations with limited sensorimotor control. Published by Elsevier Ltd.

  14. Laser ion source with solenoid field

    Science.gov (United States)

    Kanesue, Takeshi; Fuwa, Yasuhiro; Kondo, Kotaro; Okamura, Masahiro

    2014-11-01

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 1011, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  15. Direct measurement of the total decay width of the top quark.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2013-11-15

    We present a measurement of the total decay width of the top quark using events with top-antitop quark pair candidates reconstructed in the final state with one charged lepton and four or more hadronic jets. We use the full Tevatron run II data set of sqrt[s]=1.96  TeV proton-antiproton collisions recorded by the CDF II detector. The top quark mass and the mass of the hadronically decaying W boson are reconstructed for each event and compared with distributions derived from simulated signal and background samples to extract the top quark width (Γtop) and the energy scale of the calorimeter jets with in situ calibration. For a top quark mass Mtop=172.5  GeV/c2, we find 1.10<Γtop<4.05  GeV at 68% confidence level, which is in agreement with the standard model expectation of 1.3 GeV and is the most precise direct measurement of the top quark width to date.

  16. RF sources for recent linear accelerator projects

    International Nuclear Information System (INIS)

    Terrien, J.C.; Faillon, G.; Guidee, P.

    1992-01-01

    We present the state of the art of high power klystrons at Thomson Tubes Electroniques, along with the main technological limitations for peak power and pulse width. Then we describe the work that is under way to upgrade performance and some of the alternative RF sources that have been developed. (Author) 3 refs., 4 figs., 2 tabs

  17. Balance (perceived and actual) and preferred stance width during pregnancy.

    Science.gov (United States)

    Jang, John; Hsiao, Katherine T; Hsiao-Wecksler, Elizabeth T

    2008-05-01

    Pregnant women often remark that their balance degrades during pregnancy; however, it appears that no studies have documented the gravida's perception of her balance nor measured direction-specific changes in balance throughout pregnancy or after delivery. Thirty women, fifteen pregnant and fifteen non-pregnant controls, were tested monthly and through 6-month postpartum. For each session, perceived degradation in sense of balance, laboratory-based balance measures, stance width, and the number of falls since the previous session were recorded. Laboratory-based balance measures, quantified by direction-specific measures of postural sway, were computed from ten 30s quiet-standing trials on a stationary force platform. Repeated-measures analysis of variance, paired t-tests, and Pearson correlations were use to examine group and time effects. For the pregnant group, perceived balance degradation and stance width were highly correlated (r = 0.94). Both increased during pregnancy (P r > 0.72) and also decreased significantly between the third trimester and postpartum (P pregnancy, but increased after delivery. Contrary to recent work suggesting fall rates of 25%, only 13% of our subjects (n = 2) fell during pregnancy. Perceived degradation in balance during pregnancy was strongly related to increasing postural sway instability in the anterior-posterior direction. Lateral stability was maintained during pregnancy and likely accomplished by increasing stance width.

  18. Finite-width effects in unstable-particle production at hadron colliders

    Energy Technology Data Exchange (ETDEWEB)

    Falgari, P. [Utrecht Univ. (Netherlands). Inst. for Theoretical Physics; Utrecht Univ. (Netherlands). Spinoza Inst.; Papanastasiou, A.S. [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Signer, A. [Paul Scherrer Institut, Villigen (Switzerland); Zuerich Univ. (Switzerland). Inst. for Theoretical Physics

    2013-03-15

    We present a general formalism for the calculation of finite-width contributions to the differential production cross sections of unstable particles at hadron colliders. In this formalism, which employs an effective-theory description of unstable-particle production and decay, the matrix element computation is organized as a gauge-invariant expansion in powers of {Gamma}{sub X}/m{sub X}, with {Gamma}{sub X} and m{sub X} the width and mass of the unstable particle. This framework allows for a systematic inclusion of off-shell and non-factorizable effects whilst at the same time keeping the computational effort minimal compared to a full calculation in the complex-mass scheme. As a proof-of-concept example, we give results for an NLO calculation of top-antitop production in the q anti q partonic channel. As already found in a similar calculation of single-top production, the finite-width effects are small for the total cross section, as expected from the naive counting {proportional_to}{Gamma}{sub t}/m{sub t}{proportional_to}1%. However, they can be sizeable, in excess of 10%, close to edges of certain kinematical distributions. The dependence of the results on the mass renormalization scheme, and its implication for a precise extraction of the top-quark mass, is also discussed.

  19. Finite-width effects in unstable-particle production at hadron colliders

    International Nuclear Information System (INIS)

    Falgari, P.; Signer, A.; Zuerich Univ.

    2013-03-01

    We present a general formalism for the calculation of finite-width contributions to the differential production cross sections of unstable particles at hadron colliders. In this formalism, which employs an effective-theory description of unstable-particle production and decay, the matrix element computation is organized as a gauge-invariant expansion in powers of Γ X /m X , with Γ X and m X the width and mass of the unstable particle. This framework allows for a systematic inclusion of off-shell and non-factorizable effects whilst at the same time keeping the computational effort minimal compared to a full calculation in the complex-mass scheme. As a proof-of-concept example, we give results for an NLO calculation of top-antitop production in the q anti q partonic channel. As already found in a similar calculation of single-top production, the finite-width effects are small for the total cross section, as expected from the naive counting ∝Γ t /m t ∝1%. However, they can be sizeable, in excess of 10%, close to edges of certain kinematical distributions. The dependence of the results on the mass renormalization scheme, and its implication for a precise extraction of the top-quark mass, is also discussed.

  20. How does floodplain width affect floodplain river ecology? A preliminary exploration using simulations

    Science.gov (United States)

    Power, Mary E.; Parker, Gary; Dietrich, William E.; Sun, Adrian

    1995-09-01

    Hydraulic food chain models allow us to explore the linkages of river discharge regimes and river-floodplain morphology to the structure and dynamics of modeled food webs. Physical conditions (e.g. depth, width, velocity) that vary with river discharge affect the performance (birth, growth, feeding, movement, or death rates) of organisms or trophic groups. Their performances in turn affect their impacts on food webs and ecosystems in channel and floodplain habitats. Here we explore the impact of floodplain width (modeled as 1 ×, 10× and 40× the channel width) on a food web with two energy sources (detritus and vegetation), invertebrates that consume these, a size structured fish population which consumes invertebrates and in which larger fish cannibalize small fish, and birds which feed on large fish. Hydraulic linkages to trophic dynamics are assumed to be mediated in three ways: birds feed efficiently only in shallow water; plant carrying capacity varies non-linearly with water velocity, and mobile and drifting organisms are diluted and concentrated with spillover of river discharge to the floodplain, and its reconfinement to the channel. Aspects of this model are based on field observations of Junk and Bailey from the Amazon, of Sparks from the Mississippi, and on our observations of the Fly River in Papua New Guinea. The model produced several counter-intuitive results. Biomass of invertebrates and fish increased with floodplain width, but much more rapidly from 1 × to 10 × floodplains than from 10 × to 40 × floodplains. For birds, maximum biomass occurred on the 10× floodplain. Initially high bird biomass on the 40 × floodplain declined to extinction over time, because although favorable fishing conditions (shallow water) were most prolonged on the widest floodplain, this advantage was more than offset by the greater dilution of prey after spillover. Bird predation on large fish sometimes increased their biomass, by reducing cannibalism and thereby

  1. Anomalous width variation of rarefactive ion acoustic solitary waves in the context of auroral plasmas

    Directory of Open Access Journals (Sweden)

    S. S. Ghosh

    2004-01-01

    Full Text Available The presence of dynamic, large amplitude solitary waves in the auroral regions of space is well known. Since their velocities are of the order of the ion acoustic speed, they may well be considered as being generated from the nonlinear evolution of ion acoustic waves. However, they do not show the expected width-amplitude correlation for K-dV solitons. Recent POLAR observations have actually revealed that the low altitude rarefactive ion acoustic solitary waves are associated with an increase in the width with increasing amplitude. This indicates that a weakly nonlinear theory is not appropriate to describe the solitary structures in the auroral regions. In the present work, a fully nonlinear analysis based on Sagdeev pseudopotential technique has been adopted for both parallel and oblique propagation of rarefactive solitary waves in a two electron temperature multi-ion plasma. The large amplitude solutions have consistently shown an increase in the width with increasing amplitude. The width-amplitude variation profile of obliquely propagating rarefactive solitary waves in a magnetized plasma have been compared with the recent POLAR observations. The width-amplitude variation pattern is found to fit well with the analytical results. It indicates that a fully nonlinear theory of ion acoustic solitary waves may well explain the observed anomalous width variations of large amplitude structures in the auroral region.

  2. Clinically insubstantial cognitive side effects of bitemporal electroconvulsive therapy at 0.5 msec pulse width.

    Science.gov (United States)

    Warnell, Ronald L; Swartz, Conrad M; Thomson, Alice

    2011-11-01

    We measured cognitive side effects from bitemporal electroconvulsive therapy (ECT) using stimuli of 0.5 msec pulse width 900 milliamperes (mA). Mini-Mental State Exam (MMSE) and 21-item Hamilton Rating Scale for Depression (HRSD-21) were rated within 36 hours before and 36 hours after a series of 6 bitemporal ECT sessions on 15 patients age ≥45. MMSE remained high after ECT (pre-ECT mean 29, standard deviation [SD] 1.60, post-ECT mean 28.53, SD 1.36) with no significant change. The mean HRSD-21 fell from 27.5 to 16.3. Post-ECT MMSE was significantly and markedly higher than in previous studies of bitemporal ECT; all had used ECT stimuli of pulse width at least 1 msec. With stimuli of 0.5 msec pulse width and 900 mA, 6 bitemporal ECTs did not decrease MMSE score. This result leaves no opportunity for further decrease in basic cognitive side effects, and complements published reports of stronger physiological effects with stimuli of 0.5 msec pulse width and 900 mA. ECT stimuli of 0.5 msec pulse width and 900 mA are more desirable than wider pulse widths. Six bitemporal ECT sessions using these stimuli generally will not have more cognitive side effects than treatments with other placements, allowing maintenance of full efficacy with clinically insubstantial side effects.

  3. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Science.gov (United States)

    2010-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... (10.16 cm) or less, the declaration of net quantity shall be expressed in terms of width and length in...

  4. Nano-scaled graphene platelets with a high length-to-width aspect ratio

    Science.gov (United States)

    Zhamu, Aruna; Guo, Jiusheng; Jang, Bor Z.

    2010-09-07

    This invention provides a nano-scaled graphene platelet (NGP) having a thickness no greater than 100 nm and a length-to-width ratio no less than 3 (preferably greater than 10). The NGP with a high length-to-width ratio can be prepared by using a method comprising (a) intercalating a carbon fiber or graphite fiber with an intercalate to form an intercalated fiber; (b) exfoliating the intercalated fiber to obtain an exfoliated fiber comprising graphene sheets or flakes; and (c) separating the graphene sheets or flakes to obtain nano-scaled graphene platelets. The invention also provides a nanocomposite material comprising an NGP with a high length-to-width ratio. Such a nanocomposite can become electrically conductive with a small weight fraction of NGPs. Conductive composites are particularly useful for shielding of sensitive electronic equipment against electromagnetic interference (EMI) or radio frequency interference (RFI), and for electrostatic charge dissipation.

  5. Influence of lip closure on alveolar cleft width in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Schmelzle Rainer

    2011-01-01

    Full Text Available Abstract Background The influence of surgery on growth and stability after treatment in patients with cleft lip and palate are topics still under discussion. The aim of the present study was to investigate the influence of early lip closure on the width of the alveolar cleft using dental casts. Methods A total of 44 clefts were investigated using plaster casts, 30 unilateral and 7 bilateral clefts. All infants received a passive molding plate a few days after birth. The age at the time of closure of the lip was 2.1 month in average (range 1-6 months. Plaster casts were obtained at the following stages: shortly after birth, prior to lip closure, prior to soft palate closure. We determined the width of the alveolar cleft before lip closure and prior to soft palate closure measuring the alveolar cleft width from the most lateral point of the premaxilla/anterior segment to the most medial point of the smaller segment. Results After lip closure 15 clefts presented with a width of 0 mm, meaning that the mucosa of the segments was almost touching one another. 19 clefts showed a width of up to 2 mm and 10 clefts were still over 2 mm wide. This means a reduction of 0% in 5 clefts, of 1-50% in 6 clefts, of 51-99% in 19 clefts, and of 100% in 14 clefts. Conclusions Early lip closure reduces alveolar cleft width. In most cases our aim of a remaining cleft width of 2 mm or less can be achieved. These are promising conditions for primary alveolar bone grafting to restore the dental bony arch.

  6. Natural widths of atomic K and L levels, Kα X-ray lines and several KLL Auger lines

    International Nuclear Information System (INIS)

    Krause, M.O.; Oliver, J.H.

    1979-01-01

    Semi-empirical values of the natural widths of K, L 1 , L 2 , and L 3 levels, Kα 1 and Kα 2 x-ray lines, and KL 1 L 1 , KL 1 L 2 and KL 2 L 3 Auger lines for the elements 10 1 ,L 2 , L 3 ) is obtained from the relation GAMMA/sub i/=GAMMA/sub R/,i/ω/sub i/, using the theoretical radiative rate GAMMA/sub R/,i from Scofield's relativistic, relaxed Hartree-Fock calculation and the fluorescence yield ω/sub i/ from Krause's evaluation. X-ray and Auger lines widths are calculated as the sums of pertinent level widths. This tabulation of natural level and line widths is internally consistent, and is compatible with all relevant experimental and theoretical information. Present semi-empirical widths, especially those of Kα 1 and Kα 2 x-rays, are compared with measured widths. Uncertainties of semi-empirical values are estimated

  7. Impact of MLC leaf width on the quality of the dose distribution in partial breast irradiation

    International Nuclear Information System (INIS)

    Height, Felicity J.; Kron, Tomas; Willis, David; Chua, Boon H.

    2012-01-01

    Partial-breast irradiation (PBI) aims to limit the target volume for radiotherapy in women with early breast cancer after partial mastectomy to the region at highest risk of local recurrence, the tumor bed. Multileaf collimators are used to achieve conformal radiation beam portals required for PBI. Narrower leaf widths are generally assumed to allow more conformal shaping of beam portals around irregularly shaped target volumes. The aim was to compare 5-mm and 10-mm leaf widths for patients previously treated using PBI and assess subsequent planning target volume (PTV) coverage and organ at risk (OAR) doses for 16 patients. Several plans (5-mm leaf width or 10-mm leaf width) were generated for each patient using the original treated plan as the basis for attempts at further optimization. Alternating between different leaf widths found no significant difference in terms of overall PTV coverage and OAR doses between treatment plans. Optimization of the original treated plan allowed a small decrease in ipsilateral breast dose, which was offset by a lower PTV minimum. No significant dosimetric difference was found to support an advantage of 5-mm over 10-mm leaf width in this setting.

  8. The cryogenic source of slow monochromatic positrons

    International Nuclear Information System (INIS)

    Meshkov, I.N.; Pavlov, V.N.; Sidorin, A.O.; Yakovenko, S.L.

    2008-01-01

    The cryogenic source of slow monochromatic positrons based on the 22 Na isotope has been designed and constructed at JINR. Positrons emitted from radioactive source 22 Na have a very broad energy spectrum up to 0.5 MeV. To generate monochromatic beam of slow positrons the solid neon is used as a moderator. The solid neon allows forming slow positron beam of the energy of 1.2 eV at the spectrum width of 1 eV. The efficiency of moderation is 1 % of total positron flux

  9. Comparative Study of Modulation Techniques for Two-Level Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Barry W. Williams

    2016-06-01

    Full Text Available A detailed comparative study of modulation techniques for single and three phase dc-ac inverters is presented.  Sinusoidal Pulse Width Modulation, Triplen Sinusoidal Pulse Width Modulation, Space Vector Modulation, Selective Harmonic Elimination and Wavelet Modulation are assessed and compared in terms of maximum fundamental output, harmonic performance, switching losses and operational mode.  The presented modulation techniques are applied to single and three phase voltage source inverters and are simulated using SIMULINK.  The simulation results clarify the inverter performance achieved using the different modulations techniques.

  10. Comparison of H-mode barrier width with a model of neutral penetration length

    International Nuclear Information System (INIS)

    Groebner, R.J.; Mahdavi, M.A.; Leonard, A.W.; Osborne, T.H.; Brooks, N.S.; Wolf, N.S.; Porter, G.D.; Stangeby, P.C.; Colchin, R.J.; Owen, L.W.

    2004-01-01

    Pedestal studies in DIII-D find that the width of the region of steep gradient in the H-mode density is comparable with the neutral penetration length, as computed from a simple analytic model. This model has analytic solutions for the edge plasma and neutral density profiles, which are obtained from the coupled particle continuity equations for electrons and deuterium atoms. In its range of validity (edge temperature between 40 and 500 eV), the analytic model quantitatively predicts the observed decrease in the width as the pedestal density increases and the observed strong increase in the gradient of the density as the pedestal density increases. The model successfully predicts that L-mode and H-mode profiles with the same pedestal density have gradients that differ by less than a factor of 2. The width of the density barrier, measured from the edge of the electron temperature barrier, is the lower limit for the observed width of the temperature barrier. These results support the hypothesis that particle fuelling is an important part of the physics that determines the structure of the H-mode transport barrier. (author)

  11. New microfocus bremsstrahlung source based on betatron B-18 for high-resolution radiography and tomography

    Science.gov (United States)

    Rychkov, M. M.; Kaplin, V. V.; Malikov, E. L.; Smolyanskiy, V. A.; Stepanov, I. B.; Lutsenko, A. S.; Gentsel'man, V.; Vas'kovskiy, I. K.

    2018-01-01

    New microfocus source of hard bremsstrahlung (photon energy > 1 MeV), based on the betatron B-18 with a narrow Ta target inside, for high-resolution radiography and tomography is presented. The first studies of the source demonstrate its possibilities for practical applications to detect the microdefects in products made from heavy materials and to control gaps in joints of parts of composite structures of engineering facilities. The radiography method was used to investigate a compound object consisting of four vertically arranged steel bars between which surfaces were exposed gaps of 10 μm in width. The radiographic image of the object, obtained with a magnification of 2.4, illustrates the good sensitivity of detecting the gaps between adjacent bars, due to the small width of the linear focus of the bremsstrahlung source.

  12. The SOL width and the MHD interchange instability in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Kerner, W [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Pogutse, O [Kurchatov institute, Moscow (Russian Federation)

    1994-07-01

    Instabilities in the SOL plasma can strongly influence the SOL plasma behaviour and in particular the SOL width. The SOL stability analysis shows that there exists a critical ratio of the thermal energy and the magnetic energy. If the SOL beta is greater than this critical value, the magnetic field cannot prevent the plasma displacement and a strong MHD instability in the SOL occurs. In the opposite case only slower resistive instabilities can develop. A theoretical investigation of the SOL plasma stability is presented for JET single-null and double-null divertor configurations. The dependence of the stability threshold on the SOL beta and on the sheath resistance is established. Applying a simple mixing length argument gives the scaling of the SOL width. 5 refs., 2 figs.

  13. THE MECHANISM OF SURFACE DIFFUSION OF H AND D ATOMS ON AMORPHOUS SOLID WATER: EXISTENCE OF VARIOUS POTENTIAL SITES

    Energy Technology Data Exchange (ETDEWEB)

    Hama, Tetsuya; Kuwahata, Kazuaki; Watanabe, Naoki; Kouchi, Akira; Chigai, Takeshi [Institute of Low Temperature Science, Hokkaido University, Sapporo, Hokkaido 060-0819 (Japan); Kimura, Yuki [Department of Earth and Planetary Materials Science, Tohoku University, Sendai 980-8578 (Japan); Pirronello, Valerio, E-mail: hama@lowtem.hokudai.ac.jp [Dipartimento di Fisica e Astronomia, Universita' di Catania, I-95125 Catania, Sicily (Italy)

    2012-10-01

    To understand elementary processes leading to H{sub 2} formation, and the hydrogenation and deuteration reactions of adsorbed species on dust grains in dense clouds, we experimentally investigated the diffusion of atomic hydrogen and deuterium on amorphous solid water (ASW) at temperatures of 8-15 K. The present study extended our previous study for selective detections of H and D atoms, and of H{sub 2} (J = 0 and 1) and D{sub 2} (J = 0 and 1) molecules adsorbed on ASW using both photo-stimulated desorption and resonance-enhanced multiphoton ionization, to investigate potential sites on ASW for diffusion, recombination dynamics, and the diffusion mechanism of H and D atoms. Our results demonstrate that the ASW surface contains various potential sites that can be categorized into at least three groups: very shallow, middle-, and deep-potential sites, with diffusion activation energies of {<=}18, 22 (23 meV for D atoms), and {>=}30 meV, respectively. The present study pictured the outline of H{sub 2} formation on cosmic ice dust at low temperatures: H atoms landing on the dust will diffuse rapidly at the abundant shallow and middle sites on ASW, and finally become trapped at deep sites. The H atoms that arrive next recombine with such trapped H atoms to yield H{sub 2} molecules. The small isotopic difference between the diffusion of H and D atoms on ASW indicates that the diffusion mechanism can be explained by thermal hopping, at least at middle-potential sites.

  14. Mammography: Correlation of pectoral muscle width and the length in the mediolateral oblique view of the breast

    International Nuclear Information System (INIS)

    Spuur, K.; Poulos, A.; Currie, G.; Rickard, M.

    2010-01-01

    Purpose: To investigate the relationship between the width and length of the pectoral muscle in the mediolateral oblique mammogram of the breast. Method: Mammograms reviewed for this study were performed on women undergoing routine mammographic screening with BreastScreen NSW South West, Australia. The study included a total of 2800 randomly selected mediolateral oblique mammograms from examinations taken between July 2004 and September 2006. Measurements of the width and length of the pectoral muscle were recorded. Results: No statistically significant difference was demonstrated between the mean values for right and left width (p = 0.5293) or length (p = 0.2079). Matched pair analysis demonstrated a statistically significant difference width, (p = 0.0069) and length, (p = 0.0369). No relationship could be demonstrated between the width and length of the pectoral muscle, (p = 0.0701). Conclusion: The inability to determine a relationship between the width and length of the pectoral muscle suggests that these criteria should be assessed independently of each other. This new understanding of the presentation of the pectoral muscle will enable clinically relevant redevelopment of current image evaluation systems to include statistically supported mean performance values. Further research is needed to explore the relationship of width and length to other key image evaluation criteria used in mammography image quality evaluation.

  15. Electrical system for pulse-width modulated control of a power inverter using phase-shifted carrier signals and related operating methods

    Science.gov (United States)

    Welchko, Brian A [Torrance, CA

    2012-02-14

    Systems and methods are provided for pulse-width modulated control of power inverter using phase-shifted carrier signals. An electrical system comprises an energy source and a motor. The motor has a first set of windings and a second set of windings, which are electrically isolated from each other. An inverter module is coupled between the energy source and the motor and comprises a first set of phase legs coupled to the first set of windings and a second set of phase legs coupled to the second set of windings. A controller is coupled to the inverter module and is configured to achieve a desired power flow between the energy source and the motor by modulating the first set of phase legs using a first carrier signal and modulating the second set of phase legs using a second carrier signal. The second carrier signal is phase-shifted relative to the first carrier signal.

  16. Account of proton channels coupling in optical-shell description of partial proton widths of isobaric analog resonances

    International Nuclear Information System (INIS)

    Guba, V.G.; Urin, M.G.

    1983-01-01

    Quantitative analysis of partial proton width of isobaric analog resonances (IAR) for magic and near-magic (by neutrons) nuclei (at proton scattering on sup(207, 208Pb, 140 Ce, 138 Ba, 90 Zr) is conducted. Optical-shell model of nuclear reactions has been used. Quantitative interpretation of width is suggested on the base of numerical solution of integral equations for effective Coulomb field with account relation of 0 + -configurations proton-neutron hole both with continuum and with multiparticle configurations. Accountancy of relation of proton channels results in systematic 1.3-2.0 fold decrease of calculated values of widths. It permits to coordinate experimental and calculated values of width at reasonable values of parameters of optical potential. The results of calculation of reduced width are stable to variation of parameters of the model

  17. A ns-pulsed high-current electron beam source

    International Nuclear Information System (INIS)

    Guan, Gexin; Li, Youzhi; Pan, Yuli

    1988-01-01

    The behaviour of a pulse electron beam source which is composed of a gun and pulse system depends on not only the time characteristics of the gun and the pulser, but also their combination. This point become apparent if effects of the electron tansit-time between electrodes are studied. A ferrite transmission line (FTL) pulser is used as a grid driver in this source. It has advantages of providing fast risetime, large peak power output and good loading characteristics. It is these advantages of the pulser that compensates the absence of some technological conditions of manufacturing gun and makes the source better. Our testing showed that the cooperation of both the gun and the pulser produced peak currents in the range of 1 to 9 amps with widths of 2 to 2.5 ns (FWHM) at cathode-to-anode potential of 60 to 82 kv, while the grid drives are about in the range of 1 to 3 kv. In addition, the results of the testing instructed that effects of electron transit-time cannot be ignored when the pulses with widths of several nanoseconds are used as a grid drive. Based on the results, electron transit-time effects on the design of the gun and the beam performances are briefly descussed in this paper. (author)

  18. Investigation into Variations of Welding Residual Stresses and Redistribution Behaviors for Different Repair Welding Widths

    International Nuclear Information System (INIS)

    Park, Chiyong; Lee, Hweesueng; Huh, Namsu

    2014-01-01

    In this study, we investigated the variations in welding residual stresses in dissimilar metal butt weld due to width of repair welding and re-distribution behaviors resulting from similar metal welding (SMW) and mechanical loading. To this end, detailed two-dimensional axi-symmetric finite element (FE) analyses were performed considering five different repair welding widths. Based on the FE results, we first evaluated the welding residual stress distributions in repair welding. We then investigated the re-distribution behaviors of the residual stresses due to SMW and mechanical loads. It is revealed that large tensile welding residual stresses take place in the inner surface and that its distribution is affected, provided repair welding width is larger than certain value. The welding residual stresses resulting from repair welding are remarkably reduced due to SMW and mechanical loading, regardless of the width of the repair welding

  19. Width dependent transition of quantized spin-wave modes in Ni80Fe20 square nanorings

    Science.gov (United States)

    Banerjee, Chandrima; Saha, Susmita; Barman, Saswati; Rousseau, Olivier; Otani, YoshiChika; Barman, Anjan

    2014-10-01

    We investigated optically induced ultrafast magnetization dynamics in square shaped Ni80Fe20 nanorings with varying ring width. Rich spin-wave spectra are observed whose frequencies showed a strong dependence on the ring width. Micromagnetic simulations showed different types of spin-wave modes, which are quantized upto very high quantization number. In the case of widest ring, the spin-wave mode spectrum shows quantized modes along the applied field direction, which is similar to the mode spectrum of an antidot array. As the ring width decreases, additional quantization in the azimuthal direction appears causing mixed modes. In the narrowest ring, the spin-waves exhibit quantization solely in azimuthal direction. The different quantization is attributed to the variation in the internal field distribution for different ring width as obtained from micromagnetic analysis and supported by magnetic force microscopy.

  20. Analysis of statistical distributions of partial γ-widths of 98Mo neutron 3 2-resonances

    International Nuclear Information System (INIS)

    Knat'ko, V.A.; Rudak, Eh.A.; Shimanovich, E.A.

    1978-01-01

    Width distributions for E1 γ-transitions from the 98 Mo neutron 3/2 resonances to the 99 Mo low-lying levels with 1/2 + , 3/2 2 and 5/2 + spins are desribed. Considered are sets of widths corresponding to γ-transitions to the levels with 3/2 spin and positioned in the energy range from 12 to 5268 eV. On the basis of the results obtained a conclusion has been drawn that the width distribution of γ-transitions to the 3/2 + level differs from the Porter-Thomas distribution

  1. Confirmation of Maslow’s Hypothesis of Synergy: Developing an Acceptance of Selfishness at the Workplace Scale

    Directory of Open Access Journals (Sweden)

    Jiro Takaki

    2016-04-01

    Full Text Available This study aimed to develop a new Acceptance of Selfishness at the Workplace Scale (ASWS and to confirm Maslow’s hypothesis of synergy: if both a sense of contribution and acceptance of selfishness at the workplace are high, workers are psychologically healthy. In a cross-sectional study with employees of three Japanese companies, 656 workers answered a self-administered questionnaire on paper completely (response rate = 66.8%. Each questionnaire was submitted to us in a sealed envelope and analyzed. The ASWS indicated high internal consistency (Cronbach’s alpha = 0.86. Significant (p < 0.001 positive moderate correlations between ASWS scores and job control scores support the ASWS’s convergent and discriminant validity. Significant (p < 0.001 associations of ASWS scores with psychological distress and work engagement supported the ASWS’s criterion validity. In short, ASWS was a psychometrically satisfactory measure. Significant (p < 0.05 interactions between a sense of contribution and acceptance of selfishness at the workplace in linear regression models showed that when those two factors are low, psychological distress becomes high. However, when a sense of contribution and acceptance of selfishness are high, work engagement also becomes high. Thus, Maslow’s hypothesis of synergy was confirmed.

  2. Stark shifts and widths of a hydrogen atom in Debye plasmas

    International Nuclear Information System (INIS)

    Yu, A.C.H.; Ho, Y.K.

    2005-01-01

    A computational scheme has been developed and used to investigate the influence of the plasma environments on modified atomic autoionization for isolated atoms/ions by using the complex coordinate rotation method which is proved to be a very simple and powerful tool to analyze the position and the width of a resonance. The Debye screening potential is employed to describe the effects of the plasma environments. Stark shifts and widths on the ground state of hydrogen are reported for field strength up to F=0.12 a.u. Slater-type basis wave functions are used to describe the system and angular-momentum states up to L=11 are included when the external electric field is turned on. Converged results are obtained by using different maximum angular-momentum states. The modified autoionization for various Debye lengths ranging from infinite to a small value of 0.86 are reported. It has been observed that for a given temperature and under the influence of a given external electric field, the resonance energy and the autoionization width increase for increasing electron density in the plasma. A discussion on the physical implication of our results is made

  3. Thorium s-wave neutron widths from 21 to 2006 eV

    International Nuclear Information System (INIS)

    Olsen, D.K.; Ingle, R.W.; Portney, J.L.

    1981-01-01

    A 232 Th total cross section measurement in the resolved resonance region has been requested with a 2% accuracy in order to obtain resonance parameters with a 5% accuracy. These data are required for both fast and light-water breeder reactor studies. Inspection of the prior 232 Th differential data base shows several problems: the thermal cross sections seem inconsistent; the measured capture widths have large uncertanties; the two rather complete sets of measured neutron widths are systematically discrepant; and the differential data appear to give Cd capture ratios and shielded-capture resonance integrals smaller than those required by integral measurements. In order to improve the differential data base we have measured neutron transmission spectra through eight samples of 232 Th. Resonance parameters have been obtained from these data using the computer code S10B. Fits to these data up to 440 eV, which concentrated on the capture widths, have been previously reported. The results of extending these fits to 2.0 keV are reported and discussed in terms of the s-wave strength function and the dilute-capture resonance integral

  4. Nanosecond pulse-width electron diode based on dielectric wall accelerator technology

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Quantang, E-mail: zhaoquantang@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Z.M.; Yuan, P.; Cao, S.C.; Shen, X.K.; Jing, Y. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Yu, C.S. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Li, Z.P.; Liu, M.; Xiao, R.Q. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Zong, Y.; Wang, Y.R. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao, H.W. [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2013-11-21

    An electron diode using a short section of dielectric wall accelerator (DWA) has been under development at the Institute of Modern Physics (IMP), Chinese Academy of Sciences. Tests have been carried out with spark gap switches triggered by lasers. The stack voltage efficiency of a four-layer of Blumleins reached about 60–70% with gas filled spark gap switching. The generated pulse voltage of peak amplitude of 23 kV and pulse width of 5 ns is used to extract and accelerate an electron beam of 320 mA, measured by a fast current transformer. A nanosecond pulse width electron diode was achieved successfully. Furthermore, the principle of a DWA is well proven and the development details and discussions are presented in this article. -- Highlights: •The key technology of DWA, including switches and pulse forming lines were studied. •The SiC PCSS obtained from Shanghai Institute were tested. •Two layers ZIP lines (new structure) and four layers Blumlein lines were studied with laser triggered spark gap switches. •A nanosecond pulse-width electron diode based on DWA technologies is achieved and studied experimentally. •The principle of DWA is also proved by the diode.

  5. Pulse-Width-Modulating Driver for Brushless dc Motor

    Science.gov (United States)

    Salomon, Phil M.

    1991-01-01

    High-current pulse-width-modulating driver for brushless dc motor features optical coupling of timing signals from low-current control circuitry to high-current motor-driving circuitry. Provides high electrical isolation of motor-power supply, helping to prevent fast, high-current motor-driving pulses from being coupled through power supplies into control circuitry, where they interfere with low-current control signals.

  6. Laser ion source with solenoid field

    International Nuclear Information System (INIS)

    Kanesue, Takeshi; Okamura, Masahiro; Fuwa, Yasuhiro; Kondo, Kotaro

    2014-01-01

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 10 11 , which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator

  7. Laser ion source with solenoid field

    Energy Technology Data Exchange (ETDEWEB)

    Kanesue, Takeshi, E-mail: tkanesue@bnl.gov; Okamura, Masahiro [Collider-Accelerator Department, Brookhaven National Laboratory, Upton, New York 11973 (United States); Fuwa, Yasuhiro [Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-7501 (Japan); RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Kondo, Kotaro [Research Laboratory for Nuclear Reactors, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro, Tokyo 152-8550 (Japan)

    2014-11-10

    Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. The laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 10{sup 11}, which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

  8. The Super-Radiant Mechanism and the Widths of Compound Nuclear States

    International Nuclear Information System (INIS)

    Auerbach, N

    2012-01-01

    In the introduction I will present the theory of the super-radiant mechanism as applied to various phenomena. I will then discuss the statistics of resonance widths in a many-body Fermi system with open decay channels. Depending on the strength of the coupling to the continuum such systems show deviations from the standard Porter-Thomas distribution. The deviations result from the process of increasing interaction of the intrinsic states through the common decay channels. In the limit of very strong coupling this leads to super-radiance. The results I will present are important for the understanding of recent experimental data concerning the width distribution of compound neutron resonances in nuclei.

  9. Description of width and spectra of two relativistic fermions bound states

    International Nuclear Information System (INIS)

    Sidorov, A.V.; Skachkov, N.B.

    1979-01-01

    The formalism for relativistic description of two particles with spin 1/2 is constructed. Used is the two-particle three-dimensional equation, obtained by quasipotential approach. Quasipotential equation in the relativistic configurational space with OBEP potential is reduced to the system of partial equations which is the analog of nonrelativistic Hamada-Jonston system. WKB approach is used to calculate mass spectra and leptonic width of mesons in quark model. The results of the study can be applied to the calculation of mass spectra and widths of electromagnetic decays of systems of e + e - , μ + μ - , c anti c, b anti b, N anti N type

  10. No-insulation multi-width winding technique for high temperature superconducting magnet.

    Science.gov (United States)

    Hahn, Seungyong; Kim, Youngjae; Keun Park, Dong; Kim, Kwangmin; Voccio, John P; Bascuñán, Juan; Iwasa, Yukikazu

    2013-10-21

    We present a No-Insulation ( NI ) Multi-Width ( MW ) winding technique for an HTS (high temperature superconductor) magnet consisting of double-pancake (DP) coils. The NI enables an HTS magnet self-protecting and the MW minimizes the detrimental anisotropy in current-carrying capacity of HTS tape by assigning tapes of multiple widths to DP coils within a stack, widest tape to the top and bottom sections and the narrowest in the midplane section. This paper presents fabrication and test results of an NI-MW HTS magnet and demonstrates the unique features of the NI-MW technique: self-protecting and enhanced field performance, unattainable with the conventional technique.

  11. Statistical characteristics of Doppler spectral width as observed by the conjugate SuperDARN radars

    Directory of Open Access Journals (Sweden)

    K. Hosokawa

    Full Text Available We performed a statistical analysis of the occurrence distribution of Doppler spectral width around the day-side high-latitude ionosphere using data from the conjugate radar pair composed of the CUTLASS Iceland-East radar in the Northern Hemisphere and the SENSU Syowa-East radar in the Southern Hemisphere. Three types of spectral width distribution were identified: (1 an exponential-like distribution in the lower magnetic latitudes (below 72°, (2 a Gaussian-like distribution around a few degrees magnetic latitude, centered on 78°, and (3 another type of distribution in the higher magnetic latitudes (above 80°. The first two are considered to represent the geophysical regimes such as the LLBL and the cusp, respectively, because they are similar to the spectral width distributions within the LLBL and the cusp, as classified by Baker et al. (1995. The distribution found above 80° magnetic latitude has been clarified for the first time in this study. This distribution has similarities to the exponential-like distribution in the lower latitude part, although clear differences also exist in their characteristics. These three spectral width distributions are commonly identified in conjugate hemispheres. The latitudinal transition from one distribution to another exhibits basically the same trend between two hemispheres. There is, however, an interhemispheric difference in the form of the distribution around the cusp latitudes, such that spectral width values obtained from Syowa-East are larger than those from Iceland-East. On the basis of the spectral width characteristics, the average locations of the cusp and the open/closed field line boundary are estimated statistically.

    Key words. Ionosphere (ionosphere-magnetosphere inter-actions; plasma convection – Magnetospheric physics (magnetopause, cusp, and boundary layers

  12. Tire inspection machine presenting an X-ray image of the entire width of the tire

    International Nuclear Information System (INIS)

    1975-01-01

    An X-ray machine for production line inspection of tires places each tire in turn with one sector of the tire inside of a U-shaped arrangement of three fluorescent screens so that one screen faces the tread and the other two face the sides of the tire. An X-ray source inside the bead circle of the tire produces X-ray shadow pictures on the screens, which are separately viewed by a video camera, with an image of the picture on each screen transferred to a third of the target of a storage tube, so that a composite image of the entire width of the tire sector can be displayed on a picture tube. The tire is rotated step-wise for display of still pictures of every sector of the tire. (Auth.)

  13. Body sway at sea for two visual tasks and three stance widths.

    Science.gov (United States)

    Stoffregen, Thomas A; Villard, Sebastien; Yu, Yawen

    2009-12-01

    On land, body sway is influenced by stance width (the distance between the feet) and by visual tasks engaged in during stance. While wider stance can be used to stabilize the body against ship motion and crewmembers are obliged to carry out many visual tasks while standing, the influence of these factors on the kinematics of body sway has not been studied at sea. Crewmembers of the RN Atlantis stood on a force plate from which we obtained data on the positional variability of the center of pressure (COP). The sea state was 2 on the Beaufort scale. We varied stance width (5 cm, 17 cm, and 30 cm) and the nature of the visual tasks. In the Inspection task, participants viewed a plain piece of white paper, while in the Search task they counted the number of target letters that appeared in a block of text. Search task performance was similar to reports from terrestrial studies. Variability of the COP position was reduced during the Search task relative to the Inspection task. Variability was also reduced during wide stance relative to narrow stance. The influence of stance width was greater than has been observed in terrestrial studies. These results suggest that two factors that influence postural sway on land (variations in stance width and in the nature of visual tasks) also influence sway at sea. We conclude that--in mild sea states--the influence of these factors is not suppressed by ship motion.

  14. Damping width of giant dipole resonances of cold and hot nuclei: A macroscopic model

    International Nuclear Information System (INIS)

    Mughabghab, S.F.; Sonzogni, A.A.

    2002-01-01

    A phenomenological macroscopic model of the giant dipole resonance (GDR) damping width of cold and hot nuclei with ground-state spherical and near-spherical shapes is developed. The model is based on a generalized Fermi liquid model which takes into account the nuclear surface dynamics. The temperature dependence of the GDR damping width is accounted for in terms of surface and volume components. Parameter-free expressions for the damping width and the effective deformation are obtained. The model is validated with GDR measurements of the following nuclides: 39,40 K, 42 Ca, 45 Sc, 59,63 Cu, 109-120 Sn, 147 Eu, 194 Hg, and 208 Pb, and is compared with the predictions of other models

  15. Design of etch holes to compensate spring width loss for reliable resonant frequencies

    International Nuclear Information System (INIS)

    Jang, Yun-Ho; Kim, Jong-Wan; Kim, Yong-Kweon; Kim, Jung-Mu

    2012-01-01

    A pattern width loss during the fabrication of lateral silicon resonators degrades resonant frequency reliability since such a width loss causes the significant deviation of spring stiffness. Here we present a design guide for etch holes to obtain reliable resonant frequencies by controlling etch holes geometries. The new function of an etch hole is to generate the comparable amount of the width loss between springs and etch holes, in turn to minimize the effect of the spring width loss on resonant frequency shift and deviation. An analytic expression reveals that a compensation factor (CF), defined by the circumference (C u ) of a unit etch hole divided by its silicon area (A u ), is a key parameter for reliable frequencies. The protrusive etch holes were proposed and compared with square etch holes to demonstrate the frequency reliability according to CF values and etch hole shapes. The normalized resonant frequency shift and deviation of the protrusive etch hole (−13.0% ± 6.9%) were significantly improved compared to those of a square etch hole with a small CF value (−42.8% ± 14.8%). The proposed design guide based on the CF value and protrusive shapes can be used to achieve reliable resonant frequencies for high performance silicon resonators. (technical note)

  16. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  17. Surface and bulk crystallization of amorphous solid water films: Confirmation of “top-down” crystallization

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Chunqing; Smith, R. Scott; Kay, Bruce D.

    2016-10-01

    The crystallization kinetics of nanoscale amorphous solid water (ASW) films are investigated using temperature-programmed desorption (TPD) and reflection absorption infrared spectroscopy (RAIRS). TPD measurements are used to probe surface crystallization and RAIRS measurements are used to probe bulk crystallization. Isothermal TPD results show that surface crystallization is independent of the film thickness (from 100 to 1000 ML). Conversely, the RAIRS measurements show that the bulk crystallization time increases linearly with increasing film thickness. These results suggest that nucleation and crystallization begin at the ASW/vacuum interface and then the crystallization growth front propagates linearly into the bulk. This mechanism was confirmed by selective placement of an isotopic layer (5% D2O in H2O) at various positions in an ASW (H2O) film. In this case, the closer the isotopic layer was to the vacuum interface, the earlier the isotopic layer crystallized. These experiments provide direct evidence to confirm that ASW crystallization in vacuum proceeds by a “top-down” crystallization mechanism.

  18. Evaluation of Maxillary Interpremolar, Molar Width by DRNA Indices and Arch Dimension, Arch Form in Maratha Population

    Directory of Open Access Journals (Sweden)

    Nitin Dungarwal

    2013-01-01

    Conclusion: Significant correlation was found between the sum of maxillary incisors and interpremolar width but not with the intermolar width while sum of mandibular incisors showed significant correlation with the interpremolar and intermolar arch width. There is no single arch form unique to any of the ethnic groups. A new formula is proposed to determine the premolar and molar index.

  19. Relationship between red cell distribution width and early renal injury in patients with gestational diabetes mellitus.

    Science.gov (United States)

    Cheng, Dong; Zhao, Jiangtao; Jian, Liguo; Ding, Tongbin; Liu, Shichao

    2016-09-01

    Previous studies found that red cell distribution width was related to adverse cardiovascular events. However, few studies reported the relationship between red cell distribution width and early-stage renal injury in pregnant women with gestational diabetes mellitus. Using a cross-sectional design, 334 pregnant women with gestational diabetes mellitus were enrolled according to the criterion of inclusion and exclusion. Demographic and clinical examination data were collected. Depended on the urine albumin, study population were divided into case group (n = 118) and control group (n = 216). Compared with control group, the case group tend to be higher red cell distribution width level (13.6 ± 0.9 vs.12.5 ± 0.6, p gestational diabetes mellitus patients. The elevated red cell distribution width level might be a predictor of early-stage renal injury in pregnant women with gestational diabetes mellitus. As an easy and routine examination index, red cell distribution width may provide better clinical guidance when combined with other important indices.

  20. Source independence and the EPR paradox

    International Nuclear Information System (INIS)

    Mould, R.A.

    1989-01-01

    It is shown that the lines of action between the photon pairs resulting from a positronium decay are not necessarily in line with the original positronium atom. It is also shown why this 'source-independent' effect is not normally observed, although it is observable in principle. Moreover our initial concerns and some conclusions as they bear on the theory of measurement in quantum mechanics are discussed. Source-independence is shown to give a satisfactory response to a special form of the Einstein-Podolsky-Rosen paradox involving pairs of position measurements. It also leads to a nonlocal relationship between position measurements that depends on the width of the position detectors

  1. Single event effects in pulse width modulation controllers

    International Nuclear Information System (INIS)

    Penzin, S.H.; Crain, W.R.; Crawford, K.B.; Hansel, S.J.; Kirshman, J.F.; Koga, R.

    1996-01-01

    SEE testing was performed on pulse width modulation (PWM) controllers which are commonly used in switching mode power supply systems. The devices are designed using both Set-Reset (SR) flip-flops and Toggle (T) flip-flops which are vulnerable to single event upset (SEU) in a radiation environment. Depending on the implementation of the different devices the effect can be significant in spaceflight hardware

  2. Occlusal Classification in Relation to Original Cleft Width in Patients With Unilateral Cleft Lip and Palate.

    Science.gov (United States)

    Huang, Andrew H; Patel, Kamlesh B; Maschhoff, Clayton W; Huebener, Donald V; Skolnick, Gary B; Naidoo, Sybill D; Woo, Albert S

    2015-09-01

    To determine a correlation between the width of the cleft palate measured at the time of lip adhesion, definitive lip repair, and palatoplasty and the subsequent occlusal classification of patients born with unilateral cleft lip and palate. Retrospective, observational study. Referral, urban, children's hospital Participants : Dental models and records of 270 patients were analyzed. None. Angle occlusion classification. The mean age at which occlusal classification was determined was 11 ± 0.3 years. Of the children studies, 84 were diagnosed with Class I or II occlusion, 67 were diagnosed with Class III occlusion, and 119 were lost to follow up or transferred care. Mean cleft widths were significantly larger in subjects with Class III occlusion for all measures at time of lip adhesion and definitive lip repair (P cleft widths were significantly greater at the alveolus (P = .025) but not at the midportion of the hard palate (P = .35) or posterior hard palate (P = .10). Cleft widths from the lip through to the posterior hard palate are generally greater in children who are diagnosed with Class III occlusion later in life. Notably, the alveolar cleft width is significantly greater at each time point for patients who went on to develop Class III occlusion. There were no significant differences in cleft widths between patients diagnosed later with Class I and Class II occlusions.

  3. Swath width study. A simulation assessment of costs and benefits of a sensor system for agricultural application

    Science.gov (United States)

    1979-01-01

    Satellites provide an excellent platform from which to observe crops on the scale and frequency required to provide accurate crop production estimates on a worldwide basis. Multispectral imaging sensors aboard these platforms are capable of providing data from which to derive acreage and production estimates. The issue of sensor swath width was examined. The quantitative trade trade necessary to resolve the combined issue of sensor swath width, number of platforms, and their orbits was generated and are included. Problems with different swath width sensors were analyzed and an assessment of system trade-offs of swath width versus number of satellites was made for achieving Global Crop Production Forecasting.

  4. Finite Orbit Width Features in the CQL3D Code

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Y. V.; Harvey, R., E-mail: petrov@compxco.com [CompX, Del Mar (United States)

    2012-09-15

    Full text: The CQL3D Fokker-Planck equation solver is being upgraded to allow for the Finite-Orbit- Width (FOW) capabilities, which will provide an accurate description for a neoclassical transport, losses to the walls, and transfer of particles, momentum, and heat to the scrape-off layer. Two different options are discussed for implementing the FOW capabilities. In one option, the Fokker-Planck equation is solved for the distribution function of orbits centered around given flux surface; in the other, the equation is solved for the local distribution function at the outer-most point of flux surface at the midplane. Both options use a fast lookup table that allows characterization of orbits without actually tracing them. The lookup table, in effect, performs mapping from the Constants-Of-Motion space onto the (R{sub o}, u{sub o}, {theta}{sub o}) computational space on the midplane. The FOW modifications have been implemented for the formations of neutral beam source, RF quasilinear diffusion operator, particle diagnostics and collisional operator, and internal boundary conditions are being refined. Initial test runs show that in general, the FOW modifications result in a broader profiles of power absorption and RF-driven current, and accurate description of the loss cone. (author)

  5. Glomerular epithelial foot processes in normal man and rats. Distribution of true width and its intra- and inter-individual variation.

    Science.gov (United States)

    Gundersen, H J; Seefeldt, T; Osterby, R

    1980-01-01

    The width of individual glomerular epithelial foot processes appears very different on electron micrographs. A method for obtainining distributions of the true width of foot processes from that of their apparent width on electron micrographs has been developed based on geometric probability theory pertaining to a specific geometric model. Analyses of foot process width in humans and rats show a remarkable interindividual invariance implying rigid control and therefore great biological significance of foot process width or a derivative thereof. The very low inter-individual variation of the true width, shown in the present paper, makes it possible to demonstrate slight changes in rather small groups of patients or experimental animals.

  6. The new fabrication method of standard surface sources

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yasushi E-mail: yss.sato@aist.go.jp; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2004-04-01

    We developed a new fabrication method for standard surface sources by using an inkjet printer with inks in which a radioactive material is mixed to print on a sheet of paper. Three printed test patterns have been prepared: (1) 100 mmx100 mm uniformity-test patterns, (2) positional-resolution test patterns with different widths and intervals of straight lines, and (3) logarithmic intensity test patterns with different radioactive intensities. The results revealed that the fabricated standard surface sources had high uniformity, high positional resolution, arbitrary shapes and a broad intensity range.

  7. Emission-line widths and stellar-wind flows in T Tauri stars

    International Nuclear Information System (INIS)

    Sa, C.; Lago, M.T.V.T.

    1986-01-01

    Spectra are reported of T Tauri stars taken with the IPCS on the Isaac Newton Telescope at the Observatorio del Roque de los Muchachos at a dispersion of l7 A mm -1 . These were taken in order to determine emission-line widths and hence flow velocities in the winds of these stars following the successful modelling of the wind from RU Lupi using such data. Line widths in RW Aur suggest a similar pattern to the wind flow as in RU Lupi with velocities rising in the inner chromosphere of the star and then entering a 'ballistic' zone. The wind from DFTau is also similar but velocities are generally much lower and the lines sharper. (author)

  8. Vision-based weld pool boundary extraction and width measurement during keyhole fiber laser welding

    Science.gov (United States)

    Luo, Masiyang; Shin, Yung C.

    2015-01-01

    In keyhole fiber laser welding processes, the weld pool behavior is essential to determining welding quality. To better observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. This work presents a weld pool edge detection technique based on an off axial green illumination laser and a coaxial image capturing system that consists of a CMOS camera and optic filters. According to the difference of image quality, a complete developed edge detection algorithm is proposed based on the local maximum gradient of greyness searching approach and linear interpolation. The extracted weld pool geometry and the width are validated by the actual welding width measurement and predictions by a numerical multi-phase model.

  9. Design of a 'two-ion-source' charge breeder with a dual frequency ECR ion source

    International Nuclear Information System (INIS)

    Naik, D.; Naik, V.; Chakrabarti, A.; Dechoudhury, S.; Nayak, S.K.; Pandey, H.K.; Nakagawa, T.

    2005-01-01

    A charge breeder, 'two-ion-source' has been designed which consists of a surface ionisation source followed by an ECR ion source working in two-frequency mode. In this system low charge state ion beam (1+)of radioactive atoms are obtained from the first ion source close to the target chamber and landed into the ECR where those are captured and become high charged state after undergoing a multi ionisation process. This beam dynamics design has been done to optimise the maximum possible transfer of 1 + beam from the first ion source into the ECR, its full capture within the ECR zone and design of an efficient dual frequency ECR. The results shows that 1 + beam of 100 nA and 1μA (A=100) are successfully transmitted and it's beam size at the centre of ECR zone are 12 mm and 21 mm respectively, which are very less than 65 mm width ECR zone of dual frequency ECR heating at 14 GHz and 10 GHz. (author)

  10. Explicit and implicit processes in behavioural adaptation to road width.

    Science.gov (United States)

    Lewis-Evans, Ben; Charlton, Samuel G

    2006-05-01

    The finding that drivers may react to safety interventions in a way that is contrary to what was intended is the phenomenon of behavioural adaptation. This phenomenon has been demonstrated across various safety interventions and has serious implications for road safety programs the world over. The present research used a driving simulator to assess behavioural adaptation in drivers' speed and lateral displacement in response to manipulations of road width. Of interest was whether behavioural adaptation would occur and whether we could determine whether it was the result of explicit, conscious decisions or implicit perceptual processes. The results supported an implicit, zero perceived risk model of behavioural adaptation with reduced speeds on a narrowed road accompanied by increased ratings of risk and a marked inability of the participants to identify that any change in road width had occurred.

  11. Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams

    International Nuclear Information System (INIS)

    Khan, Inamullah; François, Raoul; Castel, Arnaud

    2014-01-01

    This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the beam were drawn and steel reinforcement was recovered from the beam to observe the corrosion pattern and to measure the loss of mass of steel reinforcement. Maximum steel cross-section loss of the main reinforcement and average steel cross-section loss between stirrups were plotted against the crack width. The experimental results were compared with existing models proposed by Rodriguez et al., Vidal et al. and Zhang et al. Time prediction models for a given opening threshold are also compared to experimental results. Steel cross-section loss for stirrups was also measured and was plotted against the crack width. It was observed that steel cross-section loss in the stirrups had no relationship with the crack width of longitudinal corrosion cracks. -- Highlights: •Relationship between crack and corrosion of reinforcement was investigated. •Corrosion results of natural process and then corresponds to in-situ conditions. •Comparison with time predicting model is provided. •Prediction of load-bearing capacity from crack pattern was studied

  12. Assessment of age based on the pulp cavity width of the maxillary central incisors

    Directory of Open Access Journals (Sweden)

    Uday Ginjupally

    2014-01-01

    Full Text Available Aims and Objectives: The aim of this study was to estimate the age of the patients belonging to the age group of 15 - 55 years, attending the Department of Oral Medicine and Radiology, St. Joseph Dental College and Hospital, Eluru, based on the radiographic evaluation of the pulp cavity width of the maxillary central incisors. Materials and Methods: The study group comprised of 120 subjects. Intraoral periapical radiographs of the maxillary central incisors were taken for all subjects, using the conventional paralleling angle technique and the pulp cavity width was measured at the cervical and middle third using a digital vernier caliper. The data obtained was subjected to correlation and regression analysis. Results: A negative linear relationship was obtained between the age and pulp cavity width (cervical third, r = -0.459 and middle third, r = -0.704. Cubic regression analysis was done and the regression formulae were obtained. A mean difference of 0.1 years was obtained between the estimated age and real age, indicating the reliability of the derived formula. Conclusion: It can be concluded that the width of the pulp cavity of maxillary central incisors are reliable for estimation of age.

  13. Diagnostic capability of optic nerve head rim width and retinal nerve fiber thickness in open-angle glaucoma.

    Science.gov (United States)

    Di Staso, Silvio; Agnifili, Luca; Di Staso, Federico; Climastone, Hilary; Ciancaglini, Marco; Scuderi, Gian Luca

    2018-03-01

    This study was performed to test the diagnostic capability of the minimum rim width compared to peripapillary retinal nerve fiber layer thickness in patients with glaucoma. A case control, observer masked study, was conducted. Minimum rim width and retinal nerve fiber layer thickness were assessed using the patient-specific axis traced between fovea-to-Bruch's membrane opening center axis. For both minimum rim width and retinal nerve fiber layer thickness, the regionalization in six sectors (nasal, superior-nasal, superior-temporal, temporal, inferior-temporal, and inferior-nasal) was analyzed. Eyes with at least one sector with value below the 5% or 1% normative limit of the optical coherence tomography normative database were classified as glaucomatous. The area under the receiver operator characteristic curve, the accuracy, sensitivity, specificity, and predictive positive and negative values were calculated for both minimum rim width and retinal nerve fiber layer thickness. A total of 118 eyes of 118 Caucasian subjects (80 eyes with open-angle glaucoma and 38 control eyes) were enrolled in the study. Accuracy, sensitivity, and specificity were 79.7%, 77.5%, and 84.2%, respectively, for minimum rim width and 84.7%, 82.5%, and 89.5% for retinal nerve fiber layer thickness. The positive predictive values were 0.91% and 0.94% for minimum rim width and retinal nerve fiber layer thickness, respectively, whereas the negative predictive values were 0.64% and 0.70%. The area under the receiver operator characteristic curve was 0.892 for minimum rim width and 0.938 for retinal nerve fiber layer thickness. Our results indicated that the sector analysis based on Bruch's membrane opening and fovea to disk alignment is able to detect glaucomatous defects, and that Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness showed equivalent diagnostic ability.

  14. Guidelines for Integrating Helicopter Assets into Emergency Planning

    Science.gov (United States)

    1991-07-01

    maximum. 35 TABLE 2 HELIPORT INFORMATION SOURCES Professional-and/or industry associations Airborne Law Enforcement Association ( ALEA ) 8060 Balboa Boulevard...Department of Transportation/ Federal Aviation Adminisration ATTN: Hugh Lyon (ASW-611C) Fort Worth, TX 76193-0611 81-624-5600 FAA Northwest Mountain ...indication of wind speed and direction. in areas with swirling or varying winds, such as near buildings or in mountainous areas, two or more wind

  15. Geometric methods for estimating representative sidewalk widths applied to Vienna's streetscape surfaces database

    Science.gov (United States)

    Brezina, Tadej; Graser, Anita; Leth, Ulrich

    2017-04-01

    Space, and in particular public space for movement and leisure, is a valuable and scarce resource, especially in today's growing urban centres. The distribution and absolute amount of urban space—especially the provision of sufficient pedestrian areas, such as sidewalks—is considered crucial for shaping living and mobility options as well as transport choices. Ubiquitous urban data collection and today's IT capabilities offer new possibilities for providing a relation-preserving overview and for keeping track of infrastructure changes. This paper presents three novel methods for estimating representative sidewalk widths and applies them to the official Viennese streetscape surface database. The first two methods use individual pedestrian area polygons and their geometrical representations of minimum circumscribing and maximum inscribing circles to derive a representative width of these individual surfaces. The third method utilizes aggregated pedestrian areas within the buffered street axis and results in a representative width for the corresponding road axis segment. Results are displayed as city-wide means in a 500 by 500 m grid and spatial autocorrelation based on Moran's I is studied. We also compare the results between methods as well as to previous research, existing databases and guideline requirements on sidewalk widths. Finally, we discuss possible applications of these methods for monitoring and regression analysis and suggest future methodological improvements for increased accuracy.

  16. Influence of Connector Width on the Stress Distribution of Posterior Bridges under Loading

    Directory of Open Access Journals (Sweden)

    A. Azary

    2011-06-01

    Full Text Available Objective: In all ceramic fixed partial dentures the connector area is a common fracture location. The survival time of three-unit fixed partial dentures may be improved by altering the connector design in regions of maximum tension. The purpose of this study was to determine the effect of buccolingual increase of the connector width on the stress distribution in posterior fixed partial dentures made of IPS Empress 2. To simulate the anatomical condition, we used three-dimensional finite element analysis to generate.Materials and Methods: Three models of three-unit bridges replacing the first molar were prepared. The buccolingual connector width varied from 3.0 to 5.0 mm. Bridges were vertically loaded with 600 N at one point on the central fossa of the pontic, at 12 points along the cusp-fossa contact (50 N each, or at eight points along the cusp-marginal ridge contact (75 N each. Alternatively, a load of 225 N was applied at a 45º angle from the lingual side.Results: Stress concentrations were observed within or near the connectors. The von Mises stress decreased by increasing connector width, regardless of whether the loading was applied vertically or at an angle.Conclusion: Within the limitations of this study, we conclude that increasing the connector width decreases the failure probability when a vertical or angled load is applied.

  17. Charge plasma based source/drain engineered Schottky Barrier MOSFET: Ambipolar suppression and improvement of the RF performance

    Science.gov (United States)

    Kale, Sumit; Kondekar, Pravin N.

    2018-01-01

    This paper reports a novel device structure for charge plasma based Schottky Barrier (SB) MOSFET on ultrathin SOI to suppress the ambipolar leakage current and improvement of the radio frequency (RF) performance. In the proposed device, we employ dual material for the source and drain formation. Therefore, source/drain is divided into two parts as main source/drain and source/drain extension. Erbium silicide (ErSi1.7) is used as main source/drain material and Hafnium metal is used as source/drain extension material. The source extension induces the electron plasma in the ultrathin SOI body resulting reduction of SB width at the source side. Similarly, drain extension also induces the electron plasma at the drain side. This significantly increases the SB width due to increased depletion at the drain end. As a result, the ambipolar leakage current can be suppressed. In addition, drain extension also reduces the parasitic capacitances of the proposed device to improve the RF performance. The optimization of length and work function of metal used in the drain extension is performed to achieve improvement in device performance. Moreover, the proposed device makes fabrication simpler, requires low thermal budget and free from random dopant fluctuations.

  18. Meson widths and form factor at intermediate momentum transfer in nonperturbative QCD

    International Nuclear Information System (INIS)

    Ioffe, B.L.; Smilga, A.V.

    1982-01-01

    A general method is proposed for the QCD based calculations of form factors at intermediate momentum transfer Q 2 and of the partial widths of the low-lying meson resonances. The basic idea is to use the QCD sum rules for the vertex functions. With this method the pion electromagnetic form factor along with electromagnetic form factors of rho- and A 1 mesons and transition form factors γπ → A 1 at 0.5 2 2 are calculated. The widths rho+2π and A 1 → rhoπ are also determined. +.he results are in a good agreement with experiment

  19. 78 FR 73009 - Takes of Marine Mammals Incidental to Specified Activities; U.S. Navy Training and Testing...

    Science.gov (United States)

    2013-12-04

    .... Synthetic Aperture Sonars SAS1 MF SAS systems. (SAS): Sonars in which SAS2 HF SAS systems. active acoustic... sails are not dedicated ASW events and involve multiple warfare areas. Non-Impulsive ASW for Composite... Grenades. anti-swimmer grenades to defend against hostile divers (e.g., Visit, Board, Search, and Seizure...

  20. 32 CFR 1656.12 - Job reassignment.

    Science.gov (United States)

    2010-07-01

    ... ethical beliefs or convictions as to participation in a war that led to his classification as a... Order to Perform Alternative Service under § 1656.15; (4) The ASW's employer ceases to operate an approved program or activity; (5) The ASW's employer fails to comply with terms and conditions of these...

  1. Initial study of divertor particle and heat flux width scaling in lower-single-null configuration on EAST

    International Nuclear Information System (INIS)

    Wang Liang; Xu Guosheng; Guo Houyang; Gan Kaifu; Gong Xianzu; Hu Liqun

    2013-01-01

    The dependence of divertor particle and power deposition widths on plasma current (I_p) for lower hybrid current driven (LHCD) L- and H-mode plasmas was initially studied in the Experimental Advanced Superconducting Tokamak (EAST) under a lower single null (LSN) divertor configuration. And the profile widths were obtained from the divertor triple Langmuir probe array and an infra-red (IR) camera. It is shown that the deposition widths of divertor particle and heat flux profiles both display a strong negative dependence on increasing plasma current, in L-mode, ELM-free H-mode and ELMy H-mode scenarios. The experimental results show good agreement with the heuristic SOL width model proposed by Goldston. (author)

  2. Dependence of residual displacements on the width and depth of compliant fault zones: a 3D study

    Science.gov (United States)

    Kang, J.; Duan, B.

    2011-12-01

    Compliant fault zones have been detected along active faults by seismic investigations (trapped waves and travel time analysis) and InSAR observations. However, the width and depth extent of compliant fault zones are still under debate in the community. Numerical models of dynamic rupture build a bridge between theories and the geological and geophysical observations. Theoretical 2D plane-strain studies of elastic and inelastic response of compliant fault zones to nearby earthquake have been conducted by Duan [2010] and Duan et al [2010]. In this study, we further extend the experiments to 3D with a focus on elastic response. We are specifically interested in how residual displacements depend on the structure and properties of complaint fault zones, in particular on the width and depth extent. We conduct numerical experiments on various types of fault-zone models, including fault zones with a constant width along depth, with decreasing widths along depth, and with Hanning taper profiles of velocity reduction. . Our preliminary results suggest 1) the width of anomalous horizontal residual displacement is only indicative of the width of a fault zone near the surface, and 2) the vertical residual displacement contains information of the depth extent of compliant fault zones.

  3. Nuclear structure effects on alpha reduced widths

    International Nuclear Information System (INIS)

    Toth, K.S.; Ellis-Akovali, Y.A.; Kim, H.J.; McConnell, J.W.

    1987-01-01

    A review of α widths for s-wave transitions is presented together with a discussion of the following topics: (1) a new determination of the 218 Ra half-life and its relation to reflection asymmetry in nuclei near N = 130, (2) a measurement of the 194 Pb α-decay rate and the influence of the Z = 82 gap on neutron-deficient Pb nuclei, and (3) an up-date of α-decay-rate systematics for isotopes in the rare earth and medium-weight mass regions. 16 refs., 6 figs

  4. Pulse-width modulated DC-DC power converters

    CERN Document Server

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  5. Linear intra-bone geometry dependencies of the radius: Radius length determination by maximum distal width

    International Nuclear Information System (INIS)

    Baumbach, S.F.; Krusche-Mandl, I.; Huf, W.; Mall, G.; Fialka, C.

    2012-01-01

    Purpose: The aim of the study was to investigate possible linear intra-bone geometry dependencies by determining the relation between the maximum radius length and maximum distal width in two independent populations and test for possible gender or age effects. A strong correlation can help develop more representative fracture models and osteosynthetic devices as well as aid gender and height estimation in anthropologic/forensic cases. Methods: First, maximum radius length and distal width of 100 consecutive patients, aged 20–70 years, were digitally measured on standard lower arm radiographs by two independent investigators. Second, the same measurements were performed ex vivo on a second cohort, 135 isolated, formalin fixed radii. Standard descriptive statistics as well as correlations were calculated and possible gender age influences tested for both populations separately. Results: The radiographic dataset resulted in a correlation of radius length and width of r = 0.753 (adj. R 2 = 0.563, p 2 = 0.592) and side no influence on the correlation. Radius length–width correlation for the isolated radii was r = 0.621 (adj. R 2 = 0.381, p 2 = 0.598). Conclusion: A relatively strong radius length–distal width correlation was found in two different populations, indicating that linear body proportions might not only apply to body height and axial length measurements of long bones but also to proportional dependency of bone shapes in general.

  6. Using Curved Crystals to Study Terrace-Width Distributions.

    Science.gov (United States)

    Einstein, Theodore L.

    Recent experiments on curved crystals of noble and late transition metals (Ortega and Juurlink groups) have renewed interest in terrace width distributions (TWD) for vicinal surfaces. Thus, it is timely to discuss refinements of TWD analysis that are absent from the standard reviews. Rather than by Gaussians, TWDs are better described by the generalized Wigner surmise, with a power-law rise and a Gaussian decay, thereby including effects evident for weak step repulsion: skewness and peak shifts down from the mean spacing. Curved crystals allow analysis of several mean spacings with the same substrate, so that one can check the scaling with the mean width. This is important since such scaling confirms well-established theory. Failure to scale also can provide significant insights. Complicating factors can include step touching (local double-height steps), oscillatory step interactions mediated by metallic (but not topological) surface states, short-range corrections to the inverse-square step repulsion, and accounting for the offset between adjacent layers of almost all surfaces. We discuss how to deal with these issues. For in-plane misoriented steps there are formulas to describe the stiffness but not yet the strength of the elastic interstep repulsion. Supported in part by NSF-CHE 13-05892.

  7. Decay-out from low-lying superdeformed bands in Pb isotopes: Tunneling widths in a two-level mixing model

    International Nuclear Information System (INIS)

    Wilson, A.N.; Davidson, P.M.

    2004-01-01

    A recently developed two-level mixing model of superdeformed decay is applied to evaluate the tunneling width between the superdeformed and normally deformed potential wells in 192 Pb and 194 Pb. Estimates are made of level densities and γ decay widths for levels in the normally deformed well, which are required for evaluation of the model. Experimental quasicontinuum results are used to suggest a spin-dependent reduction of the energy gap in the level spectrum, resulting in approximately constant level densities and decay widths in the normal well over the decay-out region for each isotope. However, it transpires that the model's prediction of the tunneling width is nearly independent of the normally deformed state widths for both isotopes. This observation is used to extract potential barrier heights for the two nuclei that depend mainly on experimentally determined values

  8. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  9. Spectral characteristics of light sources for S-cone stimulation.

    Science.gov (United States)

    Schlegelmilch, F; Nolte, R; Schellhorn, K; Husar, P; Henning, G; Tornow, R P

    2002-11-01

    Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.

  10. 78 FR 7049 - Takes of Marine Mammals Incidental to Specified Activities; U.S. Navy Training and Testing...

    Science.gov (United States)

    2013-01-31

    ... ship is by radar. Electromagnetic measurements of off- board electromagnetic signatures are also... detection of swimmers and other objects for the purposes of port security. Synthetic Aperture Sonars (SAS...-Impulsive ASW for Composite Anti-Submarine ASW 2,3,4; HF1; 5 Training Unit Warfare MF1,2,3,4,5,12. Exercise...

  11. Sadhana | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    The proposed ASw-GSA is also compared to original GSA, particle swarm optimization (PSO),genetic algorithm (GA), bat-inspired algorithm (BA) and grey wolf optimizer (GWO). The statistical analysis results show that ASw-GSA performs significantly better than GA and BA and as well as PSO,the original GSA and GWO.12 ...

  12. Conversion width of Σ-hyperon in nuclear matter

    International Nuclear Information System (INIS)

    Filimonov, V.A.

    1983-01-01

    Width G of ΣN→ΛN conversion for Σ - hyperon in nuclear matter on the base of one-boson exchange model is calculated. Essential compensation of contributions of diffe-- rent mesons to amplitude of the conversiop is shown to take place. As a result G decreases approximately twice as compaped with the value from exchange only by π-meson. Without accout of Pauli principle it is obtained G=15-25 MeV

  13. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT.

    Science.gov (United States)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-03-01

    The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used

  14. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

    International Nuclear Information System (INIS)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-01-01

    Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same

  15. Width/Length Ratio in Maxillary Anterior Teeth. Comparative Study of Esthetic Preferences among Professionals and Laypersons.

    Science.gov (United States)

    Álvarez-Álvarez, Lorena; Orozco-Varo, Ana; Arroyo-Cruz, Gema; Jiménez-Castellanos, Emilio

    2017-05-17

    Many studies have examined the esthetic preferences of professionals in the maxillary anterior region; however, only a few have taken into account the ratios that are more frequent within the population or other ratios suggested in the literature as ideal. Previous studies also failed to compare them with the esthetic preferences of the lay population with regards to the smile. The purpose of this study is to highlight the differences when perceiving the esthetics of smiles between general dentists and laypersons, and linking them with the width/length of the maxillary anterior teeth. Photographs of the full face of a female subject were modified with Photoshop CS regarding the length/width relationships of the 6 maxillary anterior teeth. The three modifications made were: (a) 80% length/width, (b) 85%, length/width, and (c) 85% length/width in central incisors, 80% length/width in lateral incisors and canines. Three sequences of photograph pairs were created with different ratios and presented in PowerPoint to a sample of 100 general dentists and 100 laypersons. The ratio considered as the most esthetic by the majority of the judges was 85% for central incisors and 80% for lateral incisors and canines, with a statistically significant difference (p esthetic preferences of the studied populations either due to gender or professional experience of the dentists (p > 0.01). According to the results obtained in this study, professionals and laypersons considered a width/length ratio of 85% for maxillary central incisors and 80% for lateral incisors and canines as the most esthetic for maxillary anterior teeth. These results do not support findings from other studies previously published with similar ratios in central incisors, lateral incisors, and canines. Today clinicians practice in a treatment environment where not only function and utility but also esthetics is demanded in almost every procedure. Restoring/maintaining function is considered essential in any

  16. Markov chain Monte Carlo linkage analysis: effect of bin width on the probability of linkage.

    Science.gov (United States)

    Slager, S L; Juo, S H; Durner, M; Hodge, S E

    2001-01-01

    We analyzed part of the Genetic Analysis Workshop (GAW) 12 simulated data using Monte Carlo Markov chain (MCMC) methods that are implemented in the computer program Loki. The MCMC method reports the "probability of linkage" (PL) across the chromosomal regions of interest. The point of maximum PL can then be taken as a "location estimate" for the location of the quantitative trait locus (QTL). However, Loki does not provide a formal statistical test of linkage. In this paper, we explore how the bin width used in the calculations affects the max PL and the location estimate. We analyzed age at onset (AO) and quantitative trait number 5, Q5, from 26 replicates of the general simulated data in one region where we knew a major gene, MG5, is located. For each trait, we found the max PL and the corresponding location estimate, using four different bin widths. We found that bin width, as expected, does affect the max PL and the location estimate, and we recommend that users of Loki explore how their results vary with different bin widths.

  17. Effect of temperature and ridge-width on the lasing characteristics of InAs/InP quantum-dash lasers: A thermal analysis view

    Science.gov (United States)

    Alkhazraji, E.; Khan, M. T. A.; Ragheb, A. M.; Fathallah, H.; Qureshi, K. K.; Alshebeili, S.; Khan, M. Z. M.

    2018-01-01

    We investigate the thermal characteristics of multi-stack chirped barrier thickness InAs/InGaAlAs/InP quantum-dash-in-a-well lasers of different ridge widths 2, 3, 4 and 15 μm. The effect of varying this geometrical parameter on the extracted thermal resistance and characteristic temperature, and their stability with temperature are examined. The results show an inverse relation of ridge-width with junction temperature with 2 μm device exhibiting the largest junction temperature buildup owing to an associated high thermal resistance of ∼45 °C/W. Under the light of this thermal analysis, lasing behavior of different ridge-width quantum-dash (Qdash) lasers with injection currents and operating temperatures, is investigated. Thermionic carrier escape and phonon-assisted tunneling are found to be the dominant carrier transport mechanisms resulting in wide thermal spread of carriers across the available transition states of the chirped active region. An emission coverage of ∼75 nm and 3 dB bandwidth of ∼55 nm is exhibited by the 2 μm device, thus possibly exploiting the inhomogeneous optical transitions to the fullest. Furthermore, successful external modulation of a single Qdash Fabry-Perot laser mode via injection locking is demonstrated with eye diagrams at bit rates of 2-12 Gbit/s incorporating various modulation schemes. These devices are being considered as potential light sources for future high-speed wavelength-division multiplexed optical communication systems.

  18. Effects of interventions on normalizing step width during self-paced dual-belt treadmill walking with virtual reality, a randomised controlled trial.

    Science.gov (United States)

    Oude Lansink, I L B; van Kouwenhove, L; Dijkstra, P U; Postema, K; Hijmans, J M

    2017-10-01

    Step width is increased during dual-belt treadmill walking, in self-paced mode with virtual reality. Generally a familiarization period is thought to be necessary to normalize step width. The aim of this randomised study was to analyze the effects of two interventions on step width, to reduce the familiarization period. We used the GRAIL (Gait Real-time Analysis Interactive Lab), a dual-belt treadmill with virtual reality in the self-paced mode. Thirty healthy young adults were randomly allocated to three groups and asked to walk at their preferred speed for 5min. In the first session, the control-group received no intervention, the 'walk-on-the-line'-group was instructed to walk on a line, projected on the between-belt gap of the treadmill and the feedback-group received feedback about their current step width and were asked to reduce it. Interventions started after 1min and lasted 1min. During the second session, 7-10days later, no interventions were given. Linear mixed modeling showed that interventions did not have an effect on step width after the intervention period in session 1. Initial step width (second 30s) of session 1 was larger than initial step width of session 2. Step width normalized after 2min and variation in step width stabilized after 1min. Interventions do not reduce step width after intervention period. A 2-min familiarization period is sufficient to normalize and stabilize step width, in healthy young adults, regardless of interventions. A standardized intervention to normalize step width is not necessary. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung

    2007-01-01

    By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well

  20. Effect of heating scheme on SOL width in DIII-D and EAST

    Directory of Open Access Journals (Sweden)

    L. Wang

    2017-08-01

    Full Text Available Joint DIII-D/EAST experiments in the radio-frequency (RF heated H-mode scheme with comparison to that of neutral beam (NB heated H-mode scheme were carried out on DIII-D and EAST under similar conditions to examine the effect of heating scheme on scrape-off layer (SOL width in H-mode plasmas for application to ITER. A dimensionally similar plasma equilibrium was used to match the EAST shape parameters. The divertor heat flux and SOL widths were measured with infra-red camera in DIII-D, while with divertor Langmuir probe array in EAST. It has been demonstrated on both DIII-D and EAST that RF-heated plasma has a broader SOL than NB-heated plasma when the edge electrons are effectively heated in low plasma current and low density regime with low edge collisionality. Detailed edge and pedestal profile analysis on DIII-D suggests that the low edge collisionality and ion orbit loss effect may account for the observed broadening. The joint experiment in DIII-D has also demonstrated the strong inverse dependence of SOL width on the plasma current in electron cyclotron heated (ECH H-mode plasmas.

  1. Photon acceleration-based radiation sources

    International Nuclear Information System (INIS)

    Hoffman, J. R.; Muggli, P.; Katsouleas, T.; Mori, W. B.; Joshi, C.

    1999-01-01

    The acceleration and deceleration of photons in a plasma provides the means for a series of new radiation sources. Previous work on a DC to AC Radiation Converter (DARC source) has shown variable acceleration of photons having zero frequency (i.e., an electrostatic field) to between 6 and 100 GHz (1-3). These sources all had poor guiding characteristics resulting in poor power coupling from the source to the load. Continuing research has identified a novel way to integrate the DARC source into a waveguide. The so called ''pin structure'' uses stainless steel pins inserted through the narrow side of an X band waveguide to form the electrostatic field pattern (k≠0, ω=0). The pins are spaced such that the absorption band resulting from this additional periodic structure is outside of the X band range (8-12 GHz), in which the normal waveguide characteristics are left unchanged. The power of this X band source is predicted theoretically to scale quadratically with the pin bias voltage as -800 W/(kV) 2 and have a pulse width of -1 ns. Cold tests and experimental results are presented. Applications for a high power, short pulse radiation source extends to the areas of landmine detection, improved radar resolution, and experimental investigations of molecular systems

  2. Chromospheric scaling laws, width-luminosity correlations, and the Wilson-Bappu effect

    International Nuclear Information System (INIS)

    Ayres, T.R.

    1979-01-01

    Simple scaling laws are developed to explain the thickness and mean electron density of late-type stellar chromospheres in an effort to understand why the emission cores of effectively thick resonance lines such as Ca II H and K broaden with increasing stellar luminosity (the Wilson-Bappu effect). It is shown that stellar chromospheres become thicker in mass column density as stellar gravity g decreases and that the mean chromospheric electric density n/sub e/ decreases if the chromospheric heating dF/dm is constant with height and if the total heating F/sup tot/ is independent of g. It is also shown that chromospheres becomes thicker and the mean electron density becomes larger than the total chromospheric heating increases. The predicted behavior of the K 1 minimum separation and full width at half-maximum of the Ca II emission core (W 0 ) based on the derived scaling laws agree quantitatively with the observed correlations of these widths with fundamental stellar parameters, particularly surface gravity. In addition, the predicted behavior of the K 2 peak separation and base emission width with increasing chromospheric heating is consistent with the behavior of the Ca II emission core shapes in solar plages. The analytical arguments suggest that the Wilson-Bappu effect is largely a consequence of hydrostatic equilibrium rather than chromospheric dynamics

  3. An OCD perspective of line edge and line width roughness metrology

    Science.gov (United States)

    Bonam, Ravi; Muthinti, Raja; Breton, Mary; Liu, Chi-Chun; Sieg, Stuart; Seshadri, Indira; Saulnier, Nicole; Shearer, Jeffrey; Patlolla, Raghuveer; Huang, Huai

    2017-03-01

    Metrology of nanoscale patterns poses multiple challenges that range from measurement noise, metrology errors, probe size etc. Optical Metrology has gained a lot of significance in the semiconductor industry due to its fast turn around and reliable accuracy, particularly to monitor in-line process variations. Apart from monitoring critical dimension, thickness of films, there are multiple parameters that can be extracted from Optical Metrology models3. Sidewall angles, material compositions etc., can also be modeled to acceptable accuracy. Line edge and Line Width roughness are much sought of metrology following critical dimension and its uniformity, although there has not been much development in them with optical metrology. Scanning Electron Microscopy is still used as a standard metrology technique for assessment of Line Edge and Line Width roughness. In this work we present an assessment of Optical Metrology and its ability to model roughness from a set of structures with intentional jogs to simulate both Line edge and Line width roughness at multiple amplitudes and frequencies. We also present multiple models to represent roughness and extract relevant parameters from Optical metrology. Another critical aspect of optical metrology setup is correlation of measurement to a complementary technique to calibrate models. In this work, we also present comparison of roughness parameters extracted and measured with variation of image processing conditions on a commercially available CD-SEM tool.

  4. The influence of sulcus width on simulated electric fields induced by transcranial magnetic stimulation

    Science.gov (United States)

    Janssen, A. M.; Rampersad, S. M.; Lucka, F.; Lanfer, B.; Lew, S.; Aydin, Ü.; Wolters, C. H.; Stegeman, D. F.; Oostendorp, T. F.

    2013-07-01

    Volume conduction models can help in acquiring knowledge about the distribution of the electric field induced by transcranial magnetic stimulation. One aspect of a detailed model is an accurate description of the cortical surface geometry. Since its estimation is difficult, it is important to know how accurate the geometry has to be represented. Previous studies only looked at the differences caused by neglecting the complete boundary between cerebrospinal fluid (CSF) and grey matter (Thielscher et al 2011 NeuroImage 54 234-43, Bijsterbosch et al 2012 Med. Biol. Eng. Comput. 50 671-81), or by resizing the whole brain (Wagner et al 2008 Exp. Brain Res. 186 539-50). However, due to the high conductive properties of the CSF, it can be expected that alterations in sulcus width can already have a significant effect on the distribution of the electric field. To answer this question, the sulcus width of a highly realistic head model, based on T1-, T2- and diffusion-weighted magnetic resonance images, was altered systematically. This study shows that alterations in the sulcus width do not cause large differences in the majority of the electric field values. However, considerable overestimation of sulcus width produces an overestimation of the calculated field strength, also at locations distant from the target location.

  5. PIC simulations of the trapped electron filamentation instability in finite-width electron plasma waves

    Science.gov (United States)

    Winjum, B. J.; Banks, J. W.; Berger, R. L.; Cohen, B. I.; Chapman, T.; Hittinger, J. A. F.; Rozmus, W.; Strozzi, D. J.; Brunner, S.

    2012-10-01

    We present results on the kinetic filamentation of finite-width nonlinear electron plasma waves (EPW). Using 2D simulations with the PIC code BEPS, we excite a traveling EPW with a Gaussian transverse profile and a wavenumber k0λDe= 1/3. The transverse wavenumber spectrum broadens during transverse EPW localization for small width (but sufficiently large amplitude) waves, while the spectrum narrows to a dominant k as the initial EPW width increases to the plane-wave limit. For large EPW widths, filaments can grow and destroy the wave coherence before transverse localization destroys the wave; the filaments in turn evolve individually as self-focusing EPWs. Additionally, a transverse electric field develops that affects trapped electrons, and a beam-like distribution of untrapped electrons develops between filaments and on the sides of a localizing EPW. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344 and funded by the Laboratory Research and Development Program at LLNL under project tracking code 12-ERD-061. Supported also under Grants DE-FG52-09NA29552 and NSF-Phy-0904039. Simulations were performed on UCLA's Hoffman2 and NERSC's Hopper.

  6. Surface-enhanced Raman scattering on gold nanorod pairs with interconnection bars of different widths

    KAUST Repository

    Yue, Weisheng

    2012-08-01

    We demonstrate that surface-enhanced Raman scattering (SERS) enhancement could be tuned by adjusting the width of a connection bar at the bottom of a gold nanorod pair. Arrays of gold nanorod pairs with interconnection bars of different widths at the bottom of the interspace were fabricated by electron-beam lithography and used for the SERS study. Rhodamine 6G (R6G) was used as the probe molecule for the SERS. In addition to the large SERS enhancement observed in the nanostructured substrates, the SERS enhancement increases as the width of the connection bar increases. This result provides an important method for tuning SERS enhancement. Numerical simulations of electromagnetic properties on the nanostructures were performed with CST Microwave Studio, and the results correspond well with the experimental observations. © 2012 Elsevier B.V. All rights reserved.

  7. Angular beam width of a slit-diffracted wave with noncollinear group and phase velocities

    International Nuclear Information System (INIS)

    Lock, Edwin H

    2012-01-01

    Taking magnetostatic surface wave diffraction as an example, this paper theoretically investigates the 2D diffraction pattern arising in the far-field region of a ferrite slab in the case of a plane wave with noncollinear group and phase velocities incident on a wide, arbitrarily oriented slit in an opaque screen. A universal analytical formula for the angular width of a diffracted beam is derived, which is valid for magnetostatic and other types of waves in anisotropic media and structures (including metamaterials) in 2D geometries. It is shown that the angular width of a diffracted beam in an anisotropic medium can not only take values greater or less than λ 0 /D (where λ 0 is the incident wavelength, and D is the slit width), but can also be zero under certain conditions. (methodological notes)

  8. Laser cutting of various materials: Kerf width size analysis and life cycle assessment of cutting process

    Science.gov (United States)

    Yilbas, Bekir Sami; Shaukat, Mian Mobeen; Ashraf, Farhan

    2017-08-01

    Laser cutting of various materials including Ti-6Al-4V alloy, steel 304, Inconel 625, and alumina is carried out to assess the kerf width size variation along the cut section. The life cycle assessment is carried out to determine the environmental impact of the laser cutting in terms of the material waste during the cutting process. The kerf width size is formulated and predicted using the lump parameter analysis and it is measured from the experiments. The influence of laser output power and laser cutting speed on the kerf width size variation is analyzed using the analytical tools including scanning electron and optical microscopes. In the experiments, high pressure nitrogen assisting gas is used to prevent oxidation reactions in the cutting section. It is found that the kerf width size predicted from the lump parameter analysis agrees well with the experimental data. The kerf width size variation increases with increasing laser output power. However, this behavior reverses with increasing laser cutting speed. The life cycle assessment reveals that material selection for laser cutting is critical for the environmental protection point of view. Inconel 625 contributes the most to the environmental damages; however, recycling of the waste of the laser cutting reduces this contribution.

  9. A program PULSYN01 for wide-band simulation of source radiation from a finite earthquake source/fault

    International Nuclear Information System (INIS)

    Gusev, A.A.

    2001-12-01

    The purpose of the program PULSYN01 is to apply a realistic wideband source-side input for calculation of earthquake ground motion. The source is represented as a grid of point subsources, and their seismic moment rate time functions are generated considering each of them as realizations (sample functions) of a non-stationary random process. The model is intended for use at receiver-to fault distances from far field to as small as 10-20% of the fault width. Combined with an adequate Green's function synthesizer, PULSUNT01 can be used for assessment of possible ground motion and seismic hazard in many ways, including scenario event simulation, parametric studies, and eventually stochastic hazard calculations

  10. Duoplasmatron source modifications for 3He+ operation

    Science.gov (United States)

    Schmidt, C. W.; Popovic, M.

    1998-02-01

    A duoplasmatron ion source is used to produce 25 mA of 3He+ with a pulse width of ˜80 ms at 360 Hz for acceleration to 10.5 MeV. At this energy, 3He striking water or carbon targets can produce short lived isotopes of 11C, 13N, 15O, and 18F for medical positron emission tomography (PET). A duoplasmatron ion source was chosen originally since it is capable of a sufficient singly charged helium beam with an acceptable gas consumption. Stable long-term operation of the source required a change in the filament material to molybdenum, and a careful understanding of the oxide filament conditioning, operation and geometry. Other improvements, particularly in the electronics, were helpful to increasing the reliability. The source has operated for many months at ˜2.5% duty factor without significant problems and with good stability. We report here the effort that was done to make this source understandable and reliable.

  11. Duoplasmatron source modifications for 3He+ Operation

    International Nuclear Information System (INIS)

    Schmidt, C.W.; Popovic, M.

    1997-11-01

    A duoplasmatron ion source is used to produce 25 mA of 3 He+ with a pulse width of ∼80 ms at 360 Hz for acceleration to 10.5 MeV. At this energy, 3 He striking water or carbon targets can produce short lived isotopes of 11 C, 13 N, 15 O and 18 F for medical positron emission tomography (PET). A duoplasmatron ion source was chosen originally since it is capable of a sufficient singly-charged helium beam with an acceptable gas consumption. Stable long-term operation of the source required a change in the filament material to molybdenum, and a careful understanding of the oxide filament conditioning, operation and geometry. Other improvements, particularly in the electronics, were helpful to increasing the reliability. The source has operated for many months at ∼2.5% duty factor without significant problems and with good stability. We report here the effort that was done to make this source understandable and reliable

  12. Duoplasmatron source modifications for 3He+ operation

    International Nuclear Information System (INIS)

    Schmidt, C.W.; Popovic, M.

    1998-01-01

    A duoplasmatron ion source is used to produce 25 mA of 3 He + with a pulse width of ∼80ms at 360 Hz for acceleration to 10.5 MeV. At this energy, 3 He striking water or carbon targets can produce short lived isotopes of 11 C, 13 N, 15 O, and 18 F for medical positron emission tomography (PET). A duoplasmatron ion source was chosen originally since it is capable of a sufficient singly charged helium beam with an acceptable gas consumption. Stable long-term operation of the source required a change in the filament material to molybdenum, and a careful understanding of the oxide filament conditioning, operation and geometry. Other improvements, particularly in the electronics, were helpful to increasing the reliability. The source has operated for many months at ∼2.5% duty factor without significant problems and with good stability. We report here the effort that was done to make this source understandable and reliable

  13. Ion orbit loss and pedestal width of H-mode tokamak plasmas in limiter geometry

    International Nuclear Information System (INIS)

    Xiao Xiaotao; Liu Lei; Zhang Xiaodong; Wang Shaojie

    2011-01-01

    A simple analytical model is proposed to analyze the effects of ion orbit loss on the edge radial electric field in a tokamak with limiter configuration. The analytically predicted edge radial electric field is consistent with the H-mode experiments, including the width, the magnitude, and the well-like shape. This model provides an explanation to the H-mode pedestal structure. Scaling of the pedestal width based on this model is proposed.

  14. Pole mass, width, and propagators of unstable fermions

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Sirlin, A.

    2008-01-01

    The concepts of pole mass and width are extended to unstable fermions in the general framework of parity-nonconserving gauge theories, such as the Standard Model. In contrast with the conventional on-shell definitions, these concepts are gauge independent and avoid severe unphysical singularities, properties of great importance since most fundamental fermions in nature are unstable particles. General expressions for the unrenormalized and renormalized dressed propagators of unstable fermions and their field-renormalization constants are presented. (orig.)

  15. Λ(1520) → Λγ Radiative-Decay Width

    International Nuclear Information System (INIS)

    Vavilov, D.V.; Antipov, Yu.M.; Artamonov, A.V.; Batarin, V.A.; Victorov, V.A.; Golovkin, S.V.; Gorin, Yu.P.; Eroshin, O.V.; Kozhevnikov, A.P.; Konstantinov, A.S.; Kubarovsky, V.P.; Kurshetsov, V.F.; Landsberg, L.G.; Leontiev, V.M.; Molchanov, V.V.; Mukhin, V.A.; Patalakha, D.I.; Petrenko, S.V.; Petrukhin, A.I.; Kolganov, V.Z.

    2005-01-01

    The radiative decay Λ(1520) → Λγ was recorded in the exclusive reaction p + N → Λ(1520)K + + N at the SPHINX facility. The branching ratio for this decay and the corresponding partial width were found to be, respectively, Br[Λ(1520) → Λγ] = (1.02 ± 0.21) x 10 -2 and Γ[Λ(1520) → Λγ] = 159 ± 35 keV (the quoted errors are purely statistical, the systematic errors being within 15%)

  16. Partial Widths of Nonmesonic Weak Decays of Lambda-Hypernuclei

    CERN Document Server

    Kuzmin, V A

    2002-01-01

    It is shown that the phenomenological matrix elements completely describing \\Lambda N \\to NN weak interaction in the 1p-shell nuclei can be obtained from the partial widths of nonmesonic decays of ^{10}_{\\Lambda}Be and ^{10}_{\\Lambda}B hypernuclei. It is shown that the uncertainties related to the description of nuclear structure are not essential for this task.

  17. Statistical analysis of partial reduced width distributions

    International Nuclear Information System (INIS)

    Tran Quoc Thuong.

    1973-01-01

    The aim of this study was to develop rigorous methods for analysing experimental event distributions according to a law in chi 2 and to check if the number of degrees of freedom ν is compatible with the value 1 for the reduced neutron width distribution. Two statistical methods were used (the maximum-likelihood method and the method of moments); it was shown, in a few particular cases, that ν is compatible with 1. The difference between ν and 1, if it exists, should not exceed 3%. These results confirm the validity of the compound nucleus model [fr

  18. A fluid model for the edge pressure pedestal height and width in tokamaks based on the transport constraint of particle, energy, and momentum balance

    Energy Technology Data Exchange (ETDEWEB)

    Stacey, W. M., E-mail: weston.stacey@nre.gatech.edu [Georgia Institute of Technology, Atlanta, Georgia 30332 (United States)

    2016-06-15

    A fluid model for the tokamak edge pressure profile required by the conservation of particles, momentum and energy in the presence of specified heating and fueling sources and electromagnetic and geometric parameters has been developed. Kinetics effects of ion orbit loss are incorporated into the model. The use of this model as a “transport” constraint together with a “Peeling-Ballooning (P-B)” instability constraint to achieve a prediction of edge pressure pedestal heights and widths in future tokamaks is discussed.

  19. Estimations of Atmospheric Conditions for Input to the Radar Performance Surface

    Science.gov (United States)

    2007-12-01

    distribution is unlimited 12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) This study addresses the support of non- acoustic ASW operations by...BLANK v ABSTRACT This study addresses the support of non- acoustic ASW operations by timely atmospheric and ocean surface descriptions on features...24 Figure 12. Infrared Radiation Pyrometers , model KT15.82, Wintronics 2007

  20. Regression methods to investigate the relationship between facial measurements and widths of the maxillary anterior teeth.

    Science.gov (United States)

    Isa, Zakiah Mohd; Tawfiq, Omar Farouq; Noor, Norliza Mohd; Shamsudheen, Mohd Iqbal; Rijal, Omar Mohd

    2010-03-01

    In rehabilitating edentulous patients, selecting appropriately sized teeth in the absence of preextraction records is problematic. The purpose of this study was to investigate the relationships between some facial dimensions and widths of the maxillary anterior teeth to potentially provide a guide for tooth selection. Sixty full dentate Malaysian adults (18-36 years) representing 2 ethnic groups (Malay and Chinese), with well aligned maxillary anterior teeth and minimal attrition, participated in this study. Standardized digital images of the face, viewed frontally, were recorded. Using image analyzing software, the images were used to determine the interpupillary distance (IPD), inner canthal distance (ICD), and interalar width (IA). Widths of the 6 maxillary anterior teeth were measured directly from casts of the subjects using digital calipers. Regression analyses were conducted to measure the strength of the associations between the variables (alpha=.10). The means (standard deviations) of IPD, IA, and ICD of the subjects were 62.28 (2.47), 39.36 (3.12), and 34.36 (2.15) mm, respectively. The mesiodistal diameters of the maxillary central incisors, lateral incisors, and canines were 8.54 (0.50), 7.09 (0.48), and 7.94 (0.40) mm, respectively. The width of the central incisors was highly correlated to the IPD (r=0.99), while the widths of the lateral incisors and canines were highly correlated to a combination of IPD and IA (r=0.99 and 0.94, respectively). Using regression methods, the widths of the anterior teeth within the population tested may be predicted by a combination of the facial dimensions studied. (c) 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  1. Is glans penis width a risk factor for complications after hypospadias repair?

    Science.gov (United States)

    Faasse, M A; Johnson, E K; Bowen, D K; Lindgren, B W; Maizels, M; Marcus, C R; Jovanovic, B D; Yerkes, E B

    2016-08-01

    Recent studies have suggested that a smaller glans penis size may be associated with a higher likelihood of complications after hypospadias repair. Accurate identification of risk factors other than the well-understood variable of meatal location would allow development of better prognostic models and individualized risk stratification. To test the hypothesis that a smaller width of the glans penis predicts adverse outcomes after hypospadias surgery. Prospectively recorded clinical data were reviewed from a single-institution registry of primary hypospadias repairs performed between 2011 and 2014. Follow-up records were examined for occurrence of complications. Urethroplasty complications were defined to include meatal stenosis, dehiscence, urethrocutaneous fistula, urethral stricture, and/or urethral diverticulum. The subset of meatal stenosis and dehiscence were regarded as glanular complications. Regression analyses were performed to determine association between glans width and occurrence of complications. Because pre-operative androgen stimulation is known to increase glans penis size, separate subgroup analyses were included of patients with and without pre-operative use of testosterone cream. A total of 159 patients met criteria for inclusion in the study cohort: 140 patients underwent a single-stage repair, while 19 patients had a two-stage repair. The median glans penis width was 15 mm (range 10-22). Eighty-four patients (53%) received testosterone cream pre-operatively and had a significantly wider glans penis than the 75 patients who did not (median 15.5 vs 14 mm; P penis width was not a risk factor for complications after hypospadias repair. This finding differs from the results of other recent studies and encourages further research into the value of measuring penile parameters in patients undergoing hypospadias repair. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  2. Pulsed gas feed to the ion source

    International Nuclear Information System (INIS)

    Tanaka, Shigeru; Shibata, Takemasa

    1976-11-01

    Hydrogen gas feed to the ion source of a neutral beam injector for the JFT-2 tokamak has been pulsed by a set of gas reservoir, solenoid valve and variable leak. During the pulse width the flow rate is constant except for its initial overshoot. After detailed study of the temporal behaviour, the solenoid valve and variable leak were replaced with a piezo-electric valve, resulting in improvement of the rise and decay. (auth.)

  3. Colorimetry and efficiency of white LEDs: Spectral width dependence

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Elaine; Edwards, Paul R.; Martin, Robert W. [Department of Physics, SUPA, Strathclyde University, Glasgow (United Kingdom)

    2012-03-15

    The potential colour rendering capability and efficiency of white LEDs constructed by a combination of individual red, green and blue (RGB) LEDs are analysed. The conventional measurement of colour rendering quality, the colour rendering index (CRI), is used as well as a recently proposed colour quality scale (CQS), designed to overcome some of the limitations of CRI when narrow-band emitters are being studied. The colour rendering performance is maximised by variation of the peak emission wavelength and relative intensity of the component LEDs, with the constraint that the spectral widths follow those measured in actual devices. The highest CRI achieved is 89.5, corresponding to a CQS value of 79, colour temperature of 3800 K and a luminous efficacy of radiation (LER) of 365 lm/W. By allowing the spectral width of the green LED to vary the CRI can be raised to 90.9, giving values of 82.5 and 370 lm/W for the CQS and LER, respectively. The significance of these values are discussed in terms of optimising the possible performance of RGB LEDs. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Production of extra quarks decaying to dark matter beyond the narrow width approximation at the LHC

    Science.gov (United States)

    Moretti, Stefano; O'Brien, Dermot; Panizzi, Luca; Prager, Hugo

    2017-08-01

    This paper explores the effects of finite width in processes of pair production of an extra heavy quark with charge 2 /3 (top partner) and its subsequent decay into a bosonic dark matter (DM) candidate—either scalar or vector—and SM up-type quarks at the Large Hadron Collider (LHC). This dynamics has been ignored so far in standard experimental searches of heavy quarks decaying to DM and we assess herein the regions of validity of current approaches, based on the assumption that the extra quarks have a narrow width. Further, we discuss the configurations of masses, widths and couplings where the latter breaks down.

  5. space vector pulse width modulation of a multi-level diode clamped

    African Journals Online (AJOL)

    ES Obe

    step by step development of MATLAB /SIMULINK modeling of the space vector ..... Pulse Width Mod. of Multi-Level Diode Clamped Converter 119 powergui. Discrete, .... Load. Figure 22: Block diagram of the three level DCC design. 3 LEVEL ...

  6. A New Technique for SET Pulse Width Measurement in Chains of Inverters Using Pulsed Laser Irradiation

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Fel, N.; Gaillardin, M.; Baggio, J.; Girard, S.; Flament, O.; Paillet, P.; McMorrow, D.; Melinger, J. S.; Kobayashi, D.; Hirose, K.; Saito, H.; Pouget, V.; Essely, F.; Schwank, J. R.; Flores, R. S.; Dodd, P. E.; Shaneyfelt, M. R.

    2009-01-01

    A new technique is developed to measure precisely and accurately the width of propagating voltage transients induced by irradiation of inverter chains. The technique is based on measurement of the supply current in a detection inverter, and permits a direct determination of the transient width with a 50 GHz bandwidth. (authors)

  7. Width dependent transition of quantized spin-wave modes in Ni{sub 80}Fe{sub 20} square nanorings

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Chandrima; Saha, Susmita; Barman, Saswati; Barman, Anjan, E-mail: abarman@bose.res.in [Thematic Unit of Excellence on Nanodevice Technology, Department of Condensed Matter Physics and Material Sciences, S. N. Bose National Centre for Basic Sciences, Block JD, Sector III, Salt Lake, Kolkata 700098 (India); Rousseau, Olivier [CEMS-RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Otani, YoshiChika [CEMS-RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581 (Japan)

    2014-10-28

    We investigated optically induced ultrafast magnetization dynamics in square shaped Ni{sub 80}Fe{sub 20} nanorings with varying ring width. Rich spin-wave spectra are observed whose frequencies showed a strong dependence on the ring width. Micromagnetic simulations showed different types of spin-wave modes, which are quantized upto very high quantization number. In the case of widest ring, the spin-wave mode spectrum shows quantized modes along the applied field direction, which is similar to the mode spectrum of an antidot array. As the ring width decreases, additional quantization in the azimuthal direction appears causing mixed modes. In the narrowest ring, the spin-waves exhibit quantization solely in azimuthal direction. The different quantization is attributed to the variation in the internal field distribution for different ring width as obtained from micromagnetic analysis and supported by magnetic force microscopy.

  8. Porous Alumina Films with Width-Controllable Alumina Stripes

    Directory of Open Access Journals (Sweden)

    Huang Shi-Ming

    2010-01-01

    Full Text Available Abstract Porous alumina films had been fabricated by anodizing from aluminum films after an electropolishing procedure. Alumina stripes without pores can be distinguished on the surface of the porous alumina films. The width of the alumina stripes increases proportionally with the anodizing voltage. And the pores tend to be initiated close to the alumina stripes. These phenomena can be ascribed to the electric field distribution in the alumina barrier layer caused by the geometric structure of the aluminum surface.

  9. Porous Alumina Films with Width-Controllable Alumina Stripes

    Science.gov (United States)

    2010-01-01

    Porous alumina films had been fabricated by anodizing from aluminum films after an electropolishing procedure. Alumina stripes without pores can be distinguished on the surface of the porous alumina films. The width of the alumina stripes increases proportionally with the anodizing voltage. And the pores tend to be initiated close to the alumina stripes. These phenomena can be ascribed to the electric field distribution in the alumina barrier layer caused by the geometric structure of the aluminum surface. PMID:21170406

  10. SWITCH MODE PULSE WIDTH MODULATED DC-DC CONVERTER WITH MULTIPLE POWER TRANSFORMERS

    DEFF Research Database (Denmark)

    2009-01-01

    A switch mode pulse width modulated DC-DC power converter comprises at least one first electronic circuit on a input side (1) and a second electronic circuit on a output side (2). The input side (1) and the output side (2) are coupled via at least two power transformers (T1, T2). Each power...... transformer (T1, T2) comprises a first winding (T1a, T2a) arranged in a input side converter stage (3, 4) on the input side (1) and a second winding (T1 b, T2b) arranged in a output side converter stage (5) on the output side (2), and each of the windings (T1a, T1 b, T2a, T2b) has a first end and a second end....... The first electronic circuit comprises terminals (AO, A1) for connecting a source or a load, at least one energy storage inductor (L) coupled in series with at least one of the first windings (T1a, T2a) of the power transformers (T1, T2), and for each power transformer (T1, T2), an arrangement of switches...

  11. Mode-field half-widths of Gaussian approximation for the fundamental mode of two kinds of optical waveguides

    International Nuclear Information System (INIS)

    Lian-Huang, Li; Fu-Yuan, Guo

    2009-01-01

    This paper analyzes the characteristic of matching efficiency between the fundamental mode of two kinds of optical waveguides and its Gaussian approximate field. Then, it presents a new method where the mode-field half-width of Gaussian approximation for the fundamental mode should be defined according to the maximal matching efficiency method. The relationship between the mode-field half-width of the Gaussian approximate field obtained from the maximal matching efficiency and normalized frequency is studied; furthermore, two formulas of mode-field half-widths as a function of normalized frequency are proposed

  12. Comparison of results using second-order moments with and without width correction to solve the advection equation

    International Nuclear Information System (INIS)

    Pepper, D.W.; Long, P.E.

    1978-01-01

    The method of moments is used with and without a a width-correction technique to solve the advection of a passive scalar. The method of moments is free of numerical dispersion but suffers from numerical diffusion (damping). In order to assess the effect of the width-correction procedure on reducing numerical diffusion, both versions are used to advect a passive scalar in straight-line and rotational wind fields. Although the width-correction procedure reduces numerical diffusion under some circumstances, the unmodified version of the second-moment procedure is better suited as a general method

  13. The influence of sulcus width on simulated electric fields induced by transcranial magnetic stimulation

    International Nuclear Information System (INIS)

    Janssen, A M; Rampersad, S M; Stegeman, D F; Oostendorp, T F; Lucka, F; Lanfer, B; Aydin, Ü; Wolters, C H; Lew, S

    2013-01-01

    Volume conduction models can help in acquiring knowledge about the distribution of the electric field induced by transcranial magnetic stimulation. One aspect of a detailed model is an accurate description of the cortical surface geometry. Since its estimation is difficult, it is important to know how accurate the geometry has to be represented. Previous studies only looked at the differences caused by neglecting the complete boundary between cerebrospinal fluid (CSF) and grey matter (Thielscher et al 2011 NeuroImage 54 234–43, Bijsterbosch et al 2012 Med. Biol. Eng. Comput. 50 671–81), or by resizing the whole brain (Wagner et al 2008 Exp. Brain Res. 186 539–50). However, due to the high conductive properties of the CSF, it can be expected that alterations in sulcus width can already have a significant effect on the distribution of the electric field. To answer this question, the sulcus width of a highly realistic head model, based on T1-, T2- and diffusion-weighted magnetic resonance images, was altered systematically. This study shows that alterations in the sulcus width do not cause large differences in the majority of the electric field values. However, considerable overestimation of sulcus width produces an overestimation of the calculated field strength, also at locations distant from the target location. (paper)

  14. Non-LTE equivalent widths for Si II, III and IV

    International Nuclear Information System (INIS)

    Becker, S.R.; Butler, K.

    1990-01-01

    Equivalent widths for a set of Si II, III and IV lines reliable for the determination of temperatures in the B star parameter range are given. They are calculated on a fine grid of LTE line blanketed model atmospheres and lie in the wavelength region from 4070 A to 5070 A

  15. Measurement of the mass and the width of the W boson at LEP

    CERN Document Server

    Achard, P; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Anderhub, H; Andreev, V P; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Baldew, S V; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, G J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, M; Braccini, S; Branson, J G; Brochu, F; Burger, J D; Burger, W J; Button, A J; Cai, X D; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A; Casaus, J; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Chamizo-Llatas, M; Chang, Y H; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, L; Cindolo, F; Clare, I; Clare, R; Coignet, G; Colino, N; Costantini, S; de la Cruz, B; Cucciarelli, S; van Dalen, J A; De Asmundis, R; Deglon, P; Debreczeni, J; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Van Dierendonck, D N; Dionisi, C; Dittmar, M; Doria, A; Dova, M T; Duchesneau, D; Duda, M; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Extermann, P; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Forconi, G; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gentile, S; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hou, S R; Jin, B N; Jindal, P; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kaur, M; Kienzle-Focacci, M N; Kim, J K; Kirkby, Jasper; Kittel, E W; Klimentov, A; König, A C; Kopal, M; Koutsenko, V F; Kraber, M; Krämer, R W; Krüger, A; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Le Goff, J M; Leiste, R; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Luci, C; Luminari, L; Lustermann, W; Ma, W G; Malgeri, L; Malinin, A; Maña, C; Mans, J; Martin, J P; Marzano, F; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Moulik, T; Muanza, G S; Muijs, A J M; Musy, M; Nagy, S; Nandakumar, R; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Pal, I; Palomares, C; Paolucci, P; Paramatti, R; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, F; Pedace, M; Pensotti, S; Perret-Gallix, D; Piccolo, D; Pierella, F; Pieri, M; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Pothier, J; Prokofev, D; Prokofiev, D O; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P; Rembeczki, S; Ren, D; Rescigno, M; Reucroft, S; Riemann, S; Riles, K; Roe, B P; Romero, L; Rosca, A; Rosemann, C; Rosenbleck, C; Rosier-Lees, S; Roth, S; Rubio, J A; Ruggiero, G; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Schäfer, C; Shchegelskii, V; Schopper, Herwig Franz; Schotanus, D J; Sciacca, C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A; Son, D; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Swomi, W; Szillási, Z; Tang, X W; Tarjan, P; Tauscher, L; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Ulbricht, J; Valente, E; Van de Walle, R T; Vásquez, R; Vesztergombi, G; Vetlitskii, I; Viertel, G; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Wadhwa, M; Wang, Q; Wang, X L; Wang, Z M; Weber, A; Weber, M; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Yeh, S C; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zimmermann, B; Zöller, M

    2006-01-01

    The mass and the total decay width of the W boson are measured with the L3 detector at the LEP e+e- collider using W-boson pairs produced in 0.7/fb of data collected at centre-of-mass energies between 161 and 209GeV. Combining semi-leptonic and fully-hadronic final states, the mass and the width of the W boson are determined to be mW = 80.270 +/- 0.046 +/- 0.031 GeV and GW = 2.18 +/- 0.11 +/- 0.09 GeV, where the first uncertainty is statistical and the second systematic.

  16. Is Canyon Width a Diagnostic Indicator of the Discharge of Megafloods on Earth and Mars?

    Science.gov (United States)

    Lapotre, M. G.; Lamb, M. P.

    2013-12-01

    On Earth, large floods have carved steep-walled and amphitheater-headed canyons from the Pleistocene (e.g. Box Canyon, ID) through the Holocene (e.g. Asbyrgi Canyon, Iceland), to historic times (e.g. Canyon Lake Gorge, TX). The geologic record on Mars suggests that similar floods have carved canyons by waterfall retreat about 3.5 billion years ago, when the red planet was wetter and possibly warmer. We currently lack robust paleo-hydraulic tools to reconstruct the discharge of ancient floods, especially on Mars where sediment sizes are obscured from observation. To address this issue, we hypothesize that the width of canyon escarpment is controlled by the hydraulics of the canyon-carving flood due to focusing of the flood into the canyon head. We compiled field data from multiple canyons and floods on Earth and Mars and show that there is a correlation between estimated flood discharge and canyon headwall width. To explore what sets this relationship, we identified five important parameters using dimensional analysis: the Froude number, the ratio of backwater length to canyon length, the ratio of backwater length to flood width, the ratio of canyon width to flood width, and the topographic slope upstream of the canyon. We used the hydraulic numerical modeling suite ANUGA to simulate overland flow over different canyon geometries and flood parameters to systematically explore the relative bed shear stresses along the canyon rim as a metric for flow focusing. Results show that canyons that exceed a certain length, scaling with the hydraulic backwater length, have shear stresses at their heads that are significantly higher than near the canyon mouth. Shear stresses along the rim of the canyon sidewalls are limited, in comparison to stresses along the canyon head, when the flood width is of the order of the backwater length. Flow focusing only occurs for subcritical flow. Together, these results suggest that canyons may only grow from a perturbation that is large

  17. Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

    International Nuclear Information System (INIS)

    Korenev, V. V.; Savelyev, A. V.; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V.

    2012-01-01

    Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum’s width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

  18. Influence of inhomogeneous broadening and deliberately introduced disorder on the width of the lasing spectrum of a quantum dot laser

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, V. V.; Savelyev, A. V., E-mail: savelev@mail.ioffe.ru; Zhukov, A. E.; Omelchenko, A. V.; Maximov, M. V. [Russian Academy of Sciences, Nanotechnology Research and Education Center, St. Petersburg Academic University (Russian Federation)

    2012-05-15

    Analytical expressions for the shape and width of the lasing spectra of a quantum-dot (QD) laser in the case of a small (in comparison with the spectrum width) homogeneous broadening of the QD energy levels have been obtained. It is shown that the dependence of the lasing spectrum width on the output power at room temperature is determined by two dimensionless parameters: the width of QD distribution over the optical-transition energy, normalized to temperature, and the ratio of the optical loss to the maximum gain. The optimal dimensions of the laser active region have been found to obtain a specified width of the emission spectrum at a minimum pump current. The possibility of using multilayer structures with QDs to increase the lasing spectrum's width has been analyzed. It is shown that the use of several arrays of QDs with deliberately variable optical-transition energies leads to broadening of the lasing spectra; some numerical estimates are presented.

  19. Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements

    International Nuclear Information System (INIS)

    Scott, Alison J. D.; Nahum, Alan E.; Fenwick, John D.

    2009-01-01

    The accuracy with which Monte Carlo models of photon beams generated by linear accelerators (linacs) can describe small-field dose distributions depends on the modeled width of the electron beam profile incident on the linac target. It is known that the electron focal spot width affects penumbra and cross-field profiles; here, the authors explore the extent to which source occlusion reduces linac output for smaller fields and larger spot sizes. A BEAMnrc Monte Carlo linac model has been used to investigate the variation in penumbra widths and small-field output factors with electron spot size. A formalism is developed separating head scatter factors into source occlusion and flattening filter factors. Differences between head scatter factors defined in terms of in-air energy fluence, collision kerma, and terma are explored using Monte Carlo calculations. Estimates of changes in kerma-based source occlusion and flattening filter factors with field size and focal spot width are obtained by calculating doses deposited in a narrow 2 mm wide virtual ''milliphantom'' geometry. The impact of focal spot size on phantom scatter is also explored. Modeled electron spot sizes of 0.4-0.7 mm FWHM generate acceptable matches to measured penumbra widths. However the 0.5 cm field output factor is quite sensitive to electron spot width, the measured output only being matched by calculations for a 0.7 mm spot width. Because the spectra of the unscattered primary (Ψ Π ) and head-scattered (Ψ Σ ) photon energy fluences differ, miniphantom-based collision kerma measurements do not scale precisely with total in-air energy fluence Ψ=(Ψ Π +Ψ Σ ) but with (Ψ Π +1.2Ψ Σ ). For most field sizes, on-axis collision kerma is independent of the focal spot size; but for a 0.5 cm field size and 1.0 mm spot width, it is reduced by around 7% mostly due to source occlusion. The phantom scatter factor of the 0.5 cm field also shows some spot size dependence, decreasing by 6% (relative) as

  20. Kinetic Simulations of the Self-Focusing and Dissipation of Finite-Width Electron Plasma Waves

    Energy Technology Data Exchange (ETDEWEB)

    Winjum, B. J. [Univ. of California, Los Angeles, CA (United States); Berger, R. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chapman, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Banks, J. W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Brunner, S. [Federal Inst. of Technology, Lausanne (Switzerland)

    2013-09-01

    Two-dimensional simulations, both Vlasov and particle-in-cell, are presented that show the evolution of the field and electron distribution of finite-width, nonlinear electron plasma waves. The intrinsically intertwined effects of self-focusing and dissipation of field energy caused by electron trapping are studied in simulated systems that are hundreds of wavelengths long in the transverse direction but only one wavelength long and periodic in the propagation direction. From various initial wave states, both the width at focus Δm relative to the initial width Δ0 and the maximum field amplitude at focus are shown to be a function of the growth rate of the transverse modulational instability γTPMI divided by the loss rate of field energy νE to electrons escaping the trapping region. With dissipation included, an amplitude threshold for self-focusing γTPMIE~1 is found that supports the analysis of Rose [Phys. Plasmas 12, 012318 (2005)].

  1. Analysis of bus width and delay on a fully digital signum nonlinearity chaotic oscillator

    KAUST Repository

    Mansingka, Abhinav S.; Radwan, Ahmed G.; Salama, Khaled N.; Zidan, Mohammed A.

    2012-01-01

    This paper introduces the first fully digital implementation of a 3rd order ODE-based chaotic oscillator with signum nonlinearity. A threshold bus width of 12-bits for reliable chaotic behavior is observed, below which the system output becomes periodic. Beyond this threshold, the maximum Lyapunov exponent (MLE) is shown to improve up to a peak value at 16-bits and subsequently decrease with increasing bus width. The MLE is also shown to gradually increase with number of introduced internal delay cycles until a peak value at 14 cycles, after which the system loses chaotic properties. Introduced external delay cycles are shown to rotate the attractors in 3-D phase space. Bus width and delay elements can be independently modulated to optimize the system to suit specifications. The experimental results of the system show low area and high performance on a Xilinx Virtex 4 FPGA with throughput of 13.35 Gbits/s for a 32-bit implementation.

  2. Analysis of bus width and delay on a fully digital signum nonlinearity chaotic oscillator

    KAUST Repository

    Mansingka, Abhinav S.

    2012-07-29

    This paper introduces the first fully digital implementation of a 3rd order ODE-based chaotic oscillator with signum nonlinearity. A threshold bus width of 12-bits for reliable chaotic behavior is observed, below which the system output becomes periodic. Beyond this threshold, the maximum Lyapunov exponent (MLE) is shown to improve up to a peak value at 16-bits and subsequently decrease with increasing bus width. The MLE is also shown to gradually increase with number of introduced internal delay cycles until a peak value at 14 cycles, after which the system loses chaotic properties. Introduced external delay cycles are shown to rotate the attractors in 3-D phase space. Bus width and delay elements can be independently modulated to optimize the system to suit specifications. The experimental results of the system show low area and high performance on a Xilinx Virtex 4 FPGA with throughput of 13.35 Gbits/s for a 32-bit implementation.

  3. Effect of Pulse Width on Microstructure and Hardness of FeSiB Coatings by Laser Cladding

    Directory of Open Access Journals (Sweden)

    GONG Yu-bing

    2018-03-01

    Full Text Available High-density coating with FeSiB amorphous ribbons as cladding materials on the surface of mild steel was fabricated by laser cladding. The effect of different pulse widths on formability, microstructure and microhardness of the coatings was analyzed by optical microscope(OM, X-ray diffractometer (XRD, scanning electron microscope (SEM and microhardness tester. The results show that with the increase of the pulse width, the coating dilute rate rises; the tendency of crack increases and the crack originates from surface to the interface; the degree of crystallization increases and crystallization phases are α-Fe, Fe2B and Fe3Si, fusion zone width increases and the trend of columnar crystals along the epitaxial growth becomes bigger and bigger; the microhardness firstly increases and then decreases. When pulse width is 3.2ms, the structure of the coating is compact, no hole defects, the interface exhibits a good metallurgical combination and the dilute rate is low about 23.2%. Average microhardness of the coating reaches 1192HV, which is about 10 times as much as the substrate.

  4. Single-mode pulsed dye laser pumped by using a diode-pumped Nd:YAG laser with a long pulse width

    International Nuclear Information System (INIS)

    Yi, Jong Hoon; Kim, Jin Tae; Moon, Hee Jong; Rho, Si Pyo; Han, Jae Min; Rhee, Yong Joo; Lee, Jong Min

    1999-01-01

    The lasing characteristics of a single-mode dye laser pumped by using a diode-pumped solid-state laser (DPSSL) with a high repetition rate is described. A 45-mm-long Nd:YAG rod was pumped by three CW diode arrays and it was acousto-optically Q-switched. A KTP crystal was used for intracavity frequency doubling. The pulse width of the laser ranged from 90 ns to 200 ns, depending on the diode current and the Q-switching frequency. The single-mode dye laser had a grazing incidence configuration. The pulse width of the dye laser was reduced to about 1/8 of the pumping laser pulse width. The effects of the DPSSL Q-switching frequency, the driving current, and the cavity loss on the dye laser pulse width were investigated by using a simple plane-parallel cavity. From the measured pulse width of the dye laser as a function of the reflectivity of the dye laser output coupler, we found that the cavity loss due to the frequency selection elements and the output coupler should be less than 70 % in order to avoid a drastically reduced pulse width

  5. Simulations of Liners and Test Objects for a New Atlas Advanced Radiography Source

    International Nuclear Information System (INIS)

    Morgan, D. V.; Iversen, S.; Hilko, R. A.

    2002-01-01

    The Advanced Radiographic Source (ARS) will improve the data significantly due to its smaller source width. Because of the enhanced ARS output, larger source-to-object distances are a reality. The harder ARS source will allow radiography of thick high-Z targets. The five different spectral simulations resulted in similar imaging detector weighted transmission. This work used a limited set of test objects and imaging detectors. Other test objects and imaging detectors could possibly change the MVp-sensitivity result. The effect of material motion blur must be considered for the ARS due to the expected smaller X-ray source size. This study supports the original 1.5-MVp value

  6. Mixed Non-Uniform Width / Evanescent Mode Ceramic Resonator Waveguide Filter With Wide Spurious Free Bandwidth

    OpenAIRE

    Afridi, S; Sandhu, M; Hunter, I

    2016-01-01

    This paper presents a method to improve the spurious performance of integrated ceramic waveguide filters. Nonuniform width ceramic waveguide resonator and evanescent mode ceramic resonators are employed together to the resonant frequencies of higher order modes. The proposed designs give 75% improvement in stop band response when compared to uniform width ceramic waveguide filter. Simulated results of two six pole chebyshev filters are presented here with improved stop band performance.

  7. Investigations of Orchestra Auralizations Using the Multi-Channel Multi-Source Auralization Technique

    DEFF Research Database (Denmark)

    Vigeant, Michelle; Wang, Lily M.; Rindel, Jens Holger

    2008-01-01

    a multi-channel multi-source auralization technique, involving individual five-channel anechoic recordings of each instrumental part of two symphonies. In the first study, these auralizations were subjectively compared to orchestra auralizations made using (a) a single omni-directional source, (b......) a surface source, and (c) single-channel multi-source method. Results show that the multi-source auralizations were rated to be more realistic than the surface source ones and to have larger source width than the single omni-directional source auralizations. No significant differences were found between......Room acoustics computer modeling is a tool for generating impulse responses and auralizations from modeled spaces. The auralizations are commonly made from a single-channel anechoic recording of solo instruments. For this investigation, auralizations of an entire orchestra were created using...

  8. Effect of Pulse Width on Oxygen-fed Ozonizer

    Science.gov (United States)

    Okada, Sho; Wang, Douyan; Namihira, Takao; Katsuki, Sunao; Akiyama, Hidenori

    Though general ozonizers based on silent discharge (barrier discharge) have been used to supply ozone at many industrial situations, there is still some problem, such as improvements of ozone yield. In this work, ozone was generated by pulsed discharge in order to improve the characteristics of ozone generation. It is known that a pulse width gives strong effect to the improvement of energy efficiency in exhaust gas processing. In this paper, the effect of pulse duration on ozone generation by pulsed discharge in oxygen would be reported.

  9. Storage capacity for fissile material as a function of facility shape (room length-to-width ratio)

    International Nuclear Information System (INIS)

    Altschuler, S.J.

    1975-01-01

    The results of a previous study for applying surface density methods to square room of varying size are shown to be conservative for rectangular rooms as well. The surface density required to produce criticality has been calculated as a function of the facility length-to-width ratio for a variety of room widths and unit sizes, shapes, and fissile material compositions. For a length to width ratio greater than or equal to 6, the critical surface density is essentially constant. This allows further economies since more fissile material can be stored at a given subcritical value of k/ sub eff/(0.90) in a rectangular vault of given usable area than in a square one. (U.S.)

  10. Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system

    International Nuclear Information System (INIS)

    Burmeister, Jay; McDermott, Patrick N.; Bossenberger, Todd; Ben-Josef, Edgar; Levin, Kenneth; Forman, Jeffrey D.

    2004-01-01

    This study investigates the influence of multileaf collimator (MLC) leaf width on intensity modulated radiation therapy (IMRT) plans delivered via the segmented multileaf collimator (SMLC) technique. IMRT plans were calculated using the Corvus treatment planning system for three brain, three prostate, and three pancreas cases using leaf widths of 0.5 and 1 cm. Resulting differences in plan quality and complexity are presented here. Plans calculated using a 1 cm leaf width were chosen over the 0.5 cm leaf width plans in seven out of nine cases based on clinical judgment. Conversely, optimization results revealed a superior objective function result for the 0.5 cm leaf width plans in seven out of the nine comparisons. The 1 cm leaf width objective function result was superior only for very large target volumes, indicating that expanding the solution space for plan optimization by using narrower leaves may result in a decreased probability of finding the global minimum. In the remaining cases, we can conclude that we are often not utilizing the objective function as proficiently as possible to meet our clinical goals. There was often no apparent clinically significant difference between the two plans, and in such cases the issue becomes one of plan complexity. A comparison of plan complexity revealed that the average 1 cm leaf width plan required roughly 60% fewer segments and over 40% fewer monitor units than required by 0.5 cm leaf width plans. This allows a significant decrease in whole body dose and total treatment time. For very complex IMRT plans, the treatment delivery time may affect the biologically effective dose. A clinically significant improvement in plan quality from using narrower leaves was evident only in cases with very small target volumes or those with concavities that are small with respect to the MLC leaf width. For the remaining cases investigated in this study, there was no clinical advantage to reducing the MLC leaf width from 1 to 0.5 cm. In

  11. Atmospheric influence on Arctic marginal ice zone position and width in the Atlantic sector, February-April 1979-2010

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Courtenay [University of Utah, Salt Lake City, UT (United States)

    2012-12-15

    Arctic marginal ice zone (MIZ) widths in the Atlantic sector were measured during the months of maximum sea ice extent (February-April) for years 1979-2010 using a novel method based on objective curves through idealized sea ice concentration fields that satisfied Laplace's equation. Over the record, the Labrador Sea MIZ (MIZ{sub L}) had an average width of 122 km and narrowed by 28 % while moving 254 km poleward, the Greenland Sea MIZ (MIZ{sub G}) had an average width of 98 km and narrowed by 43 % while moving 158 km west toward the Greenland coast, and the Barents Sea MIZ (MIZ{sub B}) had an average width of 136 km and moved 259 km east toward the Eurasian coast without a trend in width. Trends in MIZ position and width were consistent with a warming Arctic and decreasing sea ice concentrations over the record. Beyond the trends, NAO-like atmospheric patterns influenced interannual variability in MIZ position and width: MIZ{sub L} widened and moved southeast under anomalously strong northerly flow conducive to advection of sea ice into the Labrador Sea, MIZ{sub G} widened and moved northeast under anomalously weak northerly flow conducive to diminishing the westward component of sea ice drift, and MIZ{sub B} widened and moved poleward at the expense of pack ice under anomalously strong southwesterly flow conducive to enhancing oceanic heat flux into the Barents Sea. In addition, meridional flow anomalies associated with the NAO per se moved MIZ{sub B} east and west by modulating sea ice concentration over the Barents Sea. (orig.)

  12. Performance is not Related to Perception of Target Width in Fitts’ Law

    Directory of Open Access Journals (Sweden)

    Vanhooser Jake

    2011-12-01

    Full Text Available We report a new experiment in a series of studies in which research participants perform a Fitts’ Law repetitive task, and then are required to judge the width of the target that was utilized. The first two experiments previously reported showed no relation between perception and performance. However in those two experiments subjects were never provided with feedback on their performance. In the current study, we provided participants with their performance score. Providing their performance score did not produce a relation between target width perception and performance. We posit that sports studies that have shown this relation are the results of intimate knowledge of what it means to perform well. Our inexperienced Fitts’ Law participants lacked such an understanding.

  13. Tissue effects of Ho:YAG laser with varying fluences and pulse widths

    Science.gov (United States)

    Vari, Sandor G.; van der Veen, Maurits J.; Pergadia, Vani R.; Shi, Wei-Qiang; Duffy, J. T.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1994-02-01

    We investigated the effect of varying fluence and pulse width on the ablation rate and consequent thermal damage of the Ho:YAG (2.130 micrometers ) laser. The rate of ablation on fresh bovine knee joint tissues, fibrous cartilage, hyaline cartilage, and bone in saline was determined after varying the fluence (160 - 640 J/cm2) and pulse width (150, 250, 450 microsecond(s) ec, FWHM) at a repetition rate of 2 Hz. A 400/440 micrometers fiber was used. The ablation rate increased linearly with the fluence. In fibrocartilage, different pulse durations generated significant changes in the ablation rates, but showed minor effects on hyaline cartilage and bone. The heat of ablation for all three tissue types decreased after lengthening the pulse.

  14. A measurement of the e+e- decay width of the Z0

    International Nuclear Information System (INIS)

    Yamartino, J.M.

    1994-02-01

    This thesis presents a measurement of the partial decay width of the Z 0 to e + e - using data recorded by the SLD at the SLAC Linear Collider during the 1992 run. Based on 354 nb -1 of data, the decay width, Γ ee is measured to be 82.4 ± 3.6/3.7 ± 0.8 MeV where the first error is statistical and the second is systematic. By combining this measurement of Γ ee with the SLD measurement of A LR , the magnitude of the effective vector and axial-vector coupling constants of the electron, anti g v e and anti g a e , are determined to be 0.024 ± 0.011 and 0.498 ± 0.011 respectively

  15. Super-radiance and the widths of neutron resonances in the compound nucleus

    International Nuclear Information System (INIS)

    Auerbach, N

    2012-01-01

    In the 1950s the possibility of forming a 'super-radiant' (SR) state in a gas of atoms confined to a volume of a size smaller than the wave length of radiation was suggested by Dicke. During the years this mechanism was applied to many phenomena in many different fields. Here it is used in the discussion of the statistics of resonance widths in a many-body system with open decay channels. Depending on the strength of the coupling to the continuum such systems show deviations from the Porter-Thomas distribution. In the limit of very strong coupling this leads to super-radiance. The results presented are important for the understanding of recent experimental data concerning the widths distribution of neutron resonances in nuclei.

  16. Short-Pulse-Width Repetitively Q-Switched ~2.7-μm Er:Y2O3 Ceramic Laser

    Directory of Open Access Journals (Sweden)

    Xiaojing Ren

    2017-11-01

    Full Text Available A short-pulse-width repetitively Q-switched 2.7-μm Er:Y2O3 ceramic laser is demonstrated using a specially designed mechanical switch, a metal plate carved with slits of both slit-width and duty-cycle optimized. With a 20% transmission output coupler, stable pulse trains with durations (full-width at half-maximum, FWHM of 27–38 ns were generated with a repetition rate within the range of 0.26–4 kHz. The peak power at a 0.26 kHz repetition rate was ~3 kW.

  17. Poincaré plot width, morning urine norepinephrine levels, and autonomic imbalance in children with obstructive sleep apnea.

    Science.gov (United States)

    Chaidas, Konstantinos; Tsaoussoglou, Marina; Theodorou, Emmanouel; Lianou, Loukia; Chrousos, George; Kaditis, Athanasios G

    2014-08-01

    Obstructive sleep apnea (OSA) in childhood is accompanied by sympathetic overflow unopposed by the parasympathetic tone. Complex methods like power spectral analysis of heart rate variability have been applied to study this imbalance. In this report, width of Poincaré scattergram of the R-R interval (parasympathetic tone) and morning urine norepinephrine concentration (sympathetic activity) were used to assess autonomic imbalance. Poincaré plot was obtained from the electrocardiographic channel of nocturnal polysomnography and its width was measured, and norepinephrine-to-creatinine concentration ratio was calculated in morning urine specimen. Twenty children with obstructive sleep apnea and moderate-to-severe nocturnal hypoxemia (oxygen saturation of hemoglobin [SpO(2)] nadir plot width (318.7 ± 139.3 ms) and higher ln-transformed urine norepinephrine-to-creatinine ratio (4.5 ± 0.6) than control subjects (484.2 ± 104.4 ms and 3.8 ± 0.4, respectively; P plot width (P = 0.02). Subjects with obstructive sleep apnea and moderate-to-severe nocturnal hypoxemia have enhanced sympathetic activity and reduced parasympathetic drive. Poincaré plot width and urine norepinephrine levels are simple measures of autonomic imbalance in pediatric obstructive sleep apnea. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Impacts of yttrium substitution on FMR line-width and magnetic properties of nickel spinel ferrites

    Energy Technology Data Exchange (ETDEWEB)

    Ishaque, M., E-mail: ishaqdgk1@gmail.com [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); Khan, Muhammad Azhar, E-mail: azhar.khan@iub.edu.pk [Department of Physics, The Islamia University of Bahawalpur, Bahawalpur 63100 (Pakistan); Ali, Irshad; Khan, Hasan M. [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); Iqbal, M. Asif [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); College of E & ME, National University of Science and Technology, Islamabad (Pakistan); Islam, M.U. [Department of Physics, Bahauddin Zakariya University, Multan 60800 (Pakistan); Warsi, Muhammad Farooq [Department of Chemistry, The Islamia University of Bahawalpur, Bahawalpur 63100 (Pakistan)

    2015-05-15

    The influence of yttrium (Y) substitution on ferromagnetic resonance (FMR), initial permeability, and magnetic properties of NiFe{sub 2}O{sub 4} ferrites were investigated. It was observed that the FMR line-width decreases with yttrium contents for the substitution level 0≤×≤0.06. Beyond this, the FMR line-width increases with yttrium contents. The nominal composition NiY{sub 0.12}Fe{sub 1.88}O{sub 4} exhibited the smallest FMR line-width ~282 Oe. A significant change in FMR position of nickel–yttrium (Ni–Y) ferrites was observed and it found to exist between 4150 and 4600 Oe. The saturation magnetization was observed to decrease with the increase of yttrium contents and this was referred to the redistribution of cations on octahedral. The coercivity increased from 15 Oe to 59 Oe by increasing the yttrium concentration. The initial permeability decreased from 110 to 35 at 1 MHz by the incorporation of yttrium and this was attributed to the smaller grains which may obstruct the domain wall movement and impede the domain wall motion. The magnetic loss factors of substituted samples exhibit decreasing behavior in the frequency range 1 kHz to 10 MHz. The smaller FMR line-width and reduced magnetic loss factor of the investigated samples suggest the possible use of these materials in high frequency applications. - Highlights: • Influence of Y{sup 3+} substitution on the properties of nickel ferrites is investigated. • Very small FMR line-width (282 Oe) is exhibited by these substituted ferrites. • Fourfold increase in coercivity was observed for NiY{sub 0.24}Fe{sub 1.76}O{sub 4} ferrites.

  19. Progressive changes in arch width from primary to early mixed dentition period: a longitudinal study.

    Science.gov (United States)

    Sangwan, S; Chawla, H S; Goyal, A; Gauba, K; Mohanty, U

    2011-01-01

    The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier calliper. After 3 years follow-up, the impressions were recorded again and dental casts were prepared. Intercanine and intermolar widths were measured again at this stage and were compared with the baseline data using the paired t-test and the chi square test. There is a significant increase in the intercanine (3.93 + 1.70 mm) and intermolar width (1.49 + 1.77 mm) during the transition period from primary to early mixed dentition in both the arches and both the sexes. The gender-wise comparison showed a greater increase in males than in females, but this was not statistically significant. A thorough knowledge of growth changes during various stages of the mixed dentition period are important for a pediatric dentist to make an accurate diagnosis and treatment planning during preventive and interceptive orthodontics.

  20. Widths of atomic 4s and 4p vacancy states, Z between 46 and 50

    Science.gov (United States)

    Chen, M. H.; Crasemann, B.; Yin, L. I.; Tsang, T.; Adler, I.

    1976-01-01

    X-ray photoelectron and Auger spectra involving N sub 1, N sub 2, and N sub 3 vacancy states of Pd, Ag, Cd, In, and Sn were measured and compared with results of free-atom calculations. As previously observed in Cu and Zn Auger spectra that involve 3d-band electrons, free-atom characteristics are found, with regard to widths and structure, in the Ag and Cd M sub 4-N sub 4,5 N sub 4,5 and M sub 5-N sub 4,5 N sub 4,5 Auger spectra that arise from transitions of 4d-band electrons. Theoretical N sub 1 widths computed with calculated free-atom Auger energies agree well with measurements. Theory, however, predicts wider N sub 2 than N sub 3 vacancy states (as observed for Xe), while the measured N sub 2 and N sub 3 widths are nearly equal to each other and to the average of the calculated N sub 2 and N sub 3 widths. The calculations are made difficult by the exceedingly short lifetime of some 4 p vacancies and by the extreme sensitivity of super-Coster-Kronig rates, which dominate the deexcitation to the transition energy and to the fine details of the atomic potential.

  1. Multifractal diffusion entropy analysis: Optimal bin width of probability histograms

    Science.gov (United States)

    Jizba, Petr; Korbel, Jan

    2014-11-01

    In the framework of Multifractal Diffusion Entropy Analysis we propose a method for choosing an optimal bin-width in histograms generated from underlying probability distributions of interest. The method presented uses techniques of Rényi’s entropy and the mean squared error analysis to discuss the conditions under which the error in the multifractal spectrum estimation is minimal. We illustrate the utility of our approach by focusing on a scaling behavior of financial time series. In particular, we analyze the S&P500 stock index as sampled at a daily rate in the time period 1950-2013. In order to demonstrate a strength of the method proposed we compare the multifractal δ-spectrum for various bin-widths and show the robustness of the method, especially for large values of q. For such values, other methods in use, e.g., those based on moment estimation, tend to fail for heavy-tailed data or data with long correlations. Connection between the δ-spectrum and Rényi’s q parameter is also discussed and elucidated on a simple example of multiscale time series.

  2. Measuring river from the cloud - River width algorithm development on Google Earth Engine

    Science.gov (United States)

    Yang, X.; Pavelsky, T.; Allen, G. H.; Donchyts, G.

    2017-12-01

    Rivers are some of the most dynamic features of the terrestrial land surface. They help distribute freshwater, nutrients, sediment, and they are also responsible for some of the greatest natural hazards. Despite their importance, our understanding of river behavior is limited at the global scale, in part because we do not have a river observational dataset that spans both time and space. Remote sensing data represent a rich, largely untapped resource for observing river dynamics. In particular, publicly accessible archives of satellite optical imagery, which date back to the 1970s, can be used to study the planview morphodynamics of rivers at the global scale. Here we present an image processing algorithm developed using the Google Earth Engine cloud-based platform, that can automatically extracts river centerlines and widths from Landsat 5, 7, and 8 scenes at 30 m resolution. Our algorithm makes use of the latest monthly global surface water history dataset and an existing Global River Width from Landsat (GRWL) dataset to efficiently extract river masks from each Landsat scene. Then a combination of distance transform and skeletonization techniques are used to extract river centerlines. Finally, our algorithm calculates wetted river width at each centerline pixel perpendicular to its local centerline direction. We validated this algorithm using in situ data estimated from 16 USGS gauge stations (N=1781). We find that 92% of the width differences are within 60 m (i.e. the minimum length of 2 Landsat pixels). Leveraging Earth Engine's infrastructure of collocated data and processing power, our goal is to use this algorithm to reconstruct the morphodynamic history of rivers globally by processing over 100,000 Landsat 5 scenes, covering from 1984 to 2013.

  3. Metal vapor vacuum arc ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.; Dickinson, M.R.; Galvin, J.E.; Godechot, X.; MacGill, R.A.

    1990-06-01

    We have developed a family of metal vapor vacuum are (MEVVA) high current metal ion sources. The sources were initially developed for the production of high current beams of metal ions for heavy ion synchrotron injection for basic nuclear physics research; more recently they have also been used for metal ion implantation. A number of different embodiments of the source have been developed for these specific applications. Presently the sources operate in a pulsed mode, with pulse width of order 1 ms and repetition rate up to 100 pps. Beam extraction voltage is up to 100 kV, and since the ions produced in the vacuum arc plasma are in general multiply ionized the ion energy is up to several hundred keV. Beam current is up to several Amperes peak and around 10 mA time averaged delivered onto target. Nearly all of the solid metals of the Periodic Table have been use to produce beam. A number of novel features have been incorporated into the sources, including multiple cathodes and the ability to switch between up to 18 separate cathode materials simply and quickly, and a broad beam source version as well as miniature versions. here we review the source designs and their performance. 45 refs., 7 figs

  4. A physics-based algorithm for the estimation of bearing spall width using vibrations

    Science.gov (United States)

    Kogan, G.; Klein, R.; Bortman, J.

    2018-05-01

    Evaluation of the damage severity in a mechanical system is required for the assessment of its remaining useful life. In rotating machines, bearings are crucial components. Hence, the estimation of the size of spalls in bearings is important for prognostics of the remaining useful life. Recently, this topic has been extensively studied and many of the methods used for the estimation of spall size are based on the analysis of vibrations. A new tool is proposed in the current study for the estimation of the spall width on the outer ring raceway of a rolling element bearing. The understanding and analysis of the dynamics of the rolling element-spall interaction enabled the development of a generic and autonomous algorithm. The algorithm is generic in the sense that it does not require any human interference to make adjustments for each case. All of the algorithm's parameters are defined by analytical expressions describing the dynamics of the system. The required conditions, such as sampling rate, spall width and depth, defining the feasible region of such algorithms, are analyzed in the paper. The algorithm performance was demonstrated with experimental data for different spall widths.

  5. Studies on the Extraction Region of the Type VI RF Driven H- Ion Source

    Science.gov (United States)

    McNeely, P.; Bandyopadhyay, M.; Franzen, P.; Heinemann, B.; Hu, C.; Kraus, W.; Riedl, R.; Speth, E.; Wilhelm, R.

    2002-11-01

    IPP Garching has spent several years developing a RF driven H- ion source intended to be an alternative to the current ITER (International Thermonuclear Experimental Reactor) reference design ion source. A RF driven source offers a number of advantages to ITER in terms of reduced costs and maintenance requirements. Although the RF driven ion source has shown itself to be competitive with a standard arc filament ion source for positive ions many questions still remain on the physics behind the production of the H- ion beam extracted from the source. With the improvements that have been implemented to the BATMAN (Bavarian Test Machine for Negative Ions) facility over the last two years it is now possible to study both the extracted ion beam and the plasma in the vicinity of the extraction grid in greater detail. This paper will show the effect of changing the extraction and acceleration voltage on both the current and shape of the beam as measured on the calorimeter some 1.5 m downstream from the source. The extraction voltage required to operate in the plasma limit is 3 kV. The perveance optimum for the extraction system was determined to be 2.2 x 10-6 A/V3/2 and occurs at 2.7 kV extraction voltage. The horizontal and vertical beam half widths vary as a function of the extracted ion current and the horizontal half width is generally smaller than the vertical. The effect of reducing the co-extracted electron current via plasma grid biasing on the H- current extractable and the beam profile from the source is shown. It is possible in the case of a silver contaminated plasma to reduce the co-extracted electron current to 20% of the initial value by applying a bias of 12 V. In the case where argon is present in the plasma, biasing is observed to have minimal effect on the beam half width but in a pure hydrogen plasma the beam half width increases as the bias voltage increases. New Langmuir probe studies that have been carried out parallel to the plasma grid (in the

  6. Higgs boson width from off-shell production and decay to ZZ

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    Constraints on the total Higgs boson width, Gamma_H, are presented using off-shell production and decay to ZZ in the 4l and 2l2nu final states. The analysis is based on data collected in 2012 by the CMS experiment at the LHC, corresponding to an integrated luminosity of L = 19.7/fb at a centre-of-mass energy of 8 TeV. The combined analysis of the 4l and 2l2nu events at high mass with the 4l measurement of the Higgs boson peak at 125.6 GeV leads to an upper limit on the Higgs boson width of Gamma_H < 4.2 x Gamma_H(SM) at the 95% confidence level, assuming Gamma_H(SM) = 4.15 MeV. This result considerably improves over previous experimental constraints from direct measurements at the Higgs resonance peak.

  7. Band Width of Acoustic Resonance Frequency Relatively Natural Frequency of Fuel Rod Vibration

    Energy Technology Data Exchange (ETDEWEB)

    Proskuryakov, Konstantin Nicolaevich; Moukhine, V.S.; Novikov, K.S.; Galivets, E.Yu. [MPEI - TU, 14, Krasnokazarmennaya str., Moscow, 111250 (Russian Federation)

    2009-06-15

    In flow induced vibrations the fluid flow is the energy source that causes vibration. Acoustic resonance in piping may lead to severe problems due to over-stressing of components or significant losses of efficiency. Steady oscillatory flow in NPP primary loop can be induced by the pulsating flow introduced by reactor circulating pump or may be set up by self-excitation. Dynamic forces generated by the turbulent flow of coolant in reactor cores cause fuel rods (FR) and fuel assembly (FA) to vibrate. Flow-induced FR and FA vibrations can generally be broken into three groups: large amplitude 'resonance type' vibrations, which can cause immediate rod failure or severe damage to the rod and its support structure, middle amplitude 'within bandwidth of resonance frequency type' vibrations responsible for more gradual wear and fatigue at the contact surface between the fuel cladding and rod support and small amplitude vibrations, 'out of bandwidth of resonance frequency type' responsible for permissible wear and fatigue at the contact surface between the fuel cladding and rod support. Ultimately, these vibration types can result in a cladding breach, and therefore must be accounted for in the thermal hydraulic design of FR and FA and reactor internals. In paper the technique of definition of quality factor (Q) of acoustic contour of the coolant is presented. The value of Q defines a range of frequencies of acoustic fluctuations of the coolant within which the resonance of oscillations of the structure and the coolant is realized. Method of evaluation of so called band width (BW) of acoustic resonance frequency is worked out and presented in the paper. BW characterises the range of the frequency of coolant pressure oscillations within which the frequency of coolant pressure oscillations matches the fuel assembly's natural frequency of vibration (its resonance frequency). Paper show the way of detuning acoustic resonance from natural

  8. Experimental demonstration of line-width modulation in plasmonic lithography using a solid immersion lens-based active nano-gap control

    International Nuclear Information System (INIS)

    Lee, Won-Sup; Kim, Taeseob; Choi, Guk-Jong; Lim, Geon; Joe, Hang-Eun; Gang, Myeong-Gu; Min, Byung-Kwon; Park, No-Cheol; Moon, Hyungbae; Kim, Do-Hyung; Park, Young-Pil

    2015-01-01

    Plasmonic lithography has been used in nanofabrication because of its utility beyond the diffraction limit. The resolution of plasmonic lithography depends on the nano-gap between the nanoaperture and the photoresist surface—changing the gap distance can modulate the line-width of the pattern. In this letter, we demonstrate solid-immersion lens based active non-contact plasmonic lithography, applying a range of gap conditions to modulate the line-width of the pattern. Using a solid-immersion lens-based near-field control system, the nano-gap between the exit surface of the nanoaperture and the media can be actively modulated and maintained to within a few nanometers. The line-widths of the recorded patterns using 15- and 5-nm gaps were 47 and 19.5 nm, respectively, which matched closely the calculated full-width at half-maximum. From these results, we conclude that changing the nano-gap within a solid-immersion lens-based plasmonic head results in varying line-width patterns

  9. Study of finite-orbit-width effect on neoclassical transport in tokamak core region

    International Nuclear Information System (INIS)

    Satake, Shinsuke; Okamoto, Masao

    2004-01-01

    Neoclassical transport simulation using the δf Monte-Carlo method is carried out to investigate the finite-orbit-width (FOW) effect on the transport near the magnetic axis. The time evolution of the radial electric field to maintain the ambipolarity of the flux is calculated simultaneously. It is found that, in the near-axis region, the ion heat flux decreases from the value predicted by the standard neoclassical theory both in the banana and plateau regimes. Though the radial transport shows a strong dependence on the FOW effect, the ambipolar electric field profile at the steady state is similar to that calculated in the small-orbit-width limit approximation. (author)

  10. Elimination of threshold singularities in the relation between on-shell and pole widths

    International Nuclear Information System (INIS)

    Kniehl, Bernd A.; Palisoc, Caesar P.; Sirlin, Alberto

    2002-01-01

    In a previous communication by two of us [B. A. Kniehl and A. Sirlin, Phys. Rev. Lett. 81, 1373 (1998)], the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the standard model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m H =2√(ξ V )m V (V=W,Z), in the R ξ gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked

  11. Elimination of threshold singularities in the relation between on-shell and pole widths

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Palisoc, C.P.; Sirlin, A.

    2002-05-01

    In a previous communication by two of us, Phys. Rev. Lett. 81, 1373 (1998), the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the Standard Model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m H =2√(ξ V )m V (V=W,Z), in the R ξ gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked. (orig.)

  12. Wavelength dependence of the Brillouin spectral width of boron doped germanosilicate optical fibers.

    Science.gov (United States)

    Law, Pi-Cheng; Dragic, Peter D

    2010-08-30

    Boron co-doped germanosilicate fibers are investigated via the Brillouin light scattering technique using two wavelengths, 1534 nm and 1064 nm. Several fibers are investigated, including four drawn from the same preform but at different draw temperatures. The Stokes' shifts and the Brillouin spectral widths are found to increase with increasing fiber draw temperature. A frequency-squared law has adequately described the wavelength dependence of the Brillouin spectral width of conventional Ge-doped fibers. However, it is found that unlike conventional Ge-doped fibers these fibers do not follow the frequency-squared law. This is explained through a frequency-dependent dynamic viscosity that modifies this law.

  13. Elimination of Threshold Singularities in the Relation Between On-Shell and Pole Widths

    CERN Document Server

    Kniehl, Bernd A; Sirlin, A; Kniehl, Bernd A.; Palisoc, Caesar P.; Sirlin, Alberto

    2002-01-01

    In a previous communication by two of us, Phys. Rev. Lett. 81, 1373 (1998), the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the Standard Model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m_H = 2 root{xi_V} m_V (V = W,Z), in the R_xi gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked.

  14. Male facial width is associated with death by contact violence : Narrow-faced males are more likely to die from contact violence

    NARCIS (Netherlands)

    Stirrat, Michael; Stulp, Gert; Pollet, Thomas V.

    Male facial width-to-height ratio (bizygomatic width scaled for face height) is a testosterone-linked trait predictive of reactive aggression, exploitative behavior, cheating, deception, and dominance. We tested whether facial width was systematically related to cause of death in a forensic sample.

  15. Male facial width is associated with death by contact violence: narrow-faced males are more likely to die from contact violence

    NARCIS (Netherlands)

    Stirrat, M.; Stulp, G.; Pollet, T.V.

    2012-01-01

    Male facial width-to-height ratio (bizygomatic width scaled for face height) is a testosterone-linked trait predictive of reactive aggression, exploitative behavior, cheating, deception, and dominance. We tested whether facial width was systematically related to cause of death in a forensic sample.

  16. Downstream flow top width prediction in a river system | Choudhury ...

    African Journals Online (AJOL)

    ANFIS, ARIMA and Hybrid Multiple Inflows Muskingum models (HMIM) were applied to simulate and forecast downstream discharge and flow top widths in a river system. The ANFIS model works on a set of linguistic rules while the ARIMA model uses a set of past values to predict the next value in a time series. The HMIM ...

  17. Performance of an attention-demanding task during treadmill walking shifts the noise qualities of step-to-step variation in step width.

    Science.gov (United States)

    Grabiner, Mark D; Marone, Jane R; Wyatt, Marilynn; Sessoms, Pinata; Kaufman, Kenton R

    2018-06-01

    The fractal scaling evident in the step-to-step fluctuations of stepping-related time series reflects, to some degree, neuromotor noise. The primary purpose of this study was to determine the extent to which the fractal scaling of step width, step width and step width variability are affected by performance of an attention-demanding task. We hypothesized that the attention-demanding task would shift the structure of the step width time series toward white, uncorrelated noise. Subjects performed two 10-min treadmill walking trials, a control trial of undisturbed walking and a trial during which they performed a mental arithmetic/texting task. Motion capture data was converted to step width time series, the fractal scaling of which were determined from their power spectra. Fractal scaling decreased by 22% during the texting condition (p Step width and step width variability increased 19% and five percent, respectively (p step width fractal scaling. The change of the fractal scaling of step width is consistent with increased cognitive demand and suggests a transition in the characteristics of the signal noise. This may reflect an important advance toward the understanding of the manner in which neuromotor noise contributes to some types of falls. However, further investigation of the repeatability of the results, the sensitivity of the results to progressive increases in cognitive load imposed by attention-demanding tasks, and the extent to which the results can be generalized to the gait of older adults seems warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Optimal time-domain technique for pulse width modulation in power electronics

    Directory of Open Access Journals (Sweden)

    I. Mayergoyz

    2018-05-01

    Full Text Available Optimal time-domain technique for pulse width modulation is presented. It is based on exact and explicit analytical solutions for inverter circuits, obtained for any sequence of input voltage rectangular pulses. Two optimal criteria are discussed and illustrated by numerical examples.

  19. Boundary plasma heat flux width measurements for poloidal magnetic fields above 1 Tesla in the Alcator C-Mod tokamak

    Science.gov (United States)

    Brunner, Dan; Labombard, Brian; Kuang, Adam; Terry, Jim; Alcator C-Mod Team

    2017-10-01

    The boundary heat flux width, along with the total power flowing into the boundary, sets the power exhaust challenge for tokamaks. A multi-machine boundary heat flux width database found that the heat flux width in H-modes scaled inversely with poloidal magnetic field (Bp) and was independent of machine size. The maximum Bp in the database was 0.8 T, whereas the ITER 15 MA, Q =10 scenario will be 1.2 T. New measurements of the boundary heat flux width in Alcator C-Mod extend the international database to plasmas with Bp up to 1.3 T. C-Mod was the only experiment able to operate at ITER-level Bp. These new measurements are from over 300 plasma shots in L-, I-, and EDA H-modes spanning essentially the whole operating space in C-Mod. We find that the inverse-Bp dependence of the heat flux width in H-modes continues to ITER-level Bp, further reinforcing the empirical projection of 500 μm heat flux width for ITER. We find 50% scatter around the inverse-Bp scaling and are searching for the `hidden variables' causing this scatter. Supported by USDoE award DE-FC02-99ER54512.

  20. Assessment of alveolar bone height and width using 64-MDCT examination for dental implants

    International Nuclear Information System (INIS)

    Sekiya, Kotaro; Kaneda, Takashi; Sekiya, Keiko; Mori, Shintaro; Sakayanagi, Masashi

    2011-01-01

    There have been many reports showing the usefulness of CT examinations for preoperative dental implant treatment, and some reports on clinical statistics using CT examinations. However, there have been few reports on alveolar bone height and width of over 1,000 Japanese cases. The purpose of this study was to evaluate alveolar bone height and width of 4,123 sites in 1,056 Japanese cases using preoperative CT examinations. The subjects consisted of 4,123 regions in 1,056 cases (370 males and 686 females, mean age 56.1 years old, range 15-87) of preoperative CT examinations conducted from January 2008 to March 2009. The CT examinations were performed using the Aquilion TM 64 (Toshiba Medical Systems Corporation) as the multi detector row CT (MDCT) unit, and ZIOSTATION (ZIOSOFT) as the workstation. The CT images were displayed on the workstation, and the alveolar bone height and width were measured to one decimal place (rounded off to two decimal places). The average alveolar bone height was 14.8 mm (SD±3.8) in the upper anterior area, 11.2 mm (SD±5.5) in the upper premolar area, 6.8 mm (SD±5.4) in the upper molar area, 19.5 mm (SD±5.4) in the lower anterior area, 14.2 mm (SD±3.9) in the lower premolar area, and 13.4 mm (SD±3.4) in the lower molar area. The average alveolar bone width was 4.3 mm (SD±1.9) in the anterior area, 5.7 mm (SD±2.3) in the upper premolar area, 7.9 mm (SD±3.1) in the upper molar area, 4.8 mm (SD±2.1) in the lower anterior area, 5.9 mm (SD±2.2) in the lower premolar area, and 6.9 mm (SD±2.5) in the lower molar area. Our results using preoperative CT examinations indicated that many of the Japanese cases had insufficient alveolar bone height and width for dental implants. (author)

  1. Phase transitions of amorphous solid acetone in confined geometry investigated by reflection absorption infrared spectroscopy.

    Science.gov (United States)

    Shin, Sunghwan; Kang, Hani; Kim, Jun Soo; Kang, Heon

    2014-11-26

    We investigated the phase transformations of amorphous solid acetone under confined geometry by preparing acetone films trapped in amorphous solid water (ASW) or CCl4. Reflection absorption infrared spectroscopy (RAIRS) and temperature-programmed desorption (TPD) were used to monitor the phase changes of the acetone sample with increasing temperature. An acetone film trapped in ASW shows an abrupt change in the RAIRS features of the acetone vibrational bands during heating from 80 to 100 K, which indicates the transformation of amorphous solid acetone to a molecularly aligned crystalline phase. Further heating of the sample to 140 K produces an isotropic solid phase, and eventually a fluid phase near 157 K, at which the acetone sample is probably trapped in a pressurized, superheated condition inside the ASW matrix. Inside a CCl4 matrix, amorphous solid acetone crystallizes into a different, isotropic structure at ca. 90 K. We propose that the molecularly aligned crystalline phase formed in ASW is created by heterogeneous nucleation at the acetone-water interface, with resultant crystal growth, whereas the isotropic crystalline phase in CCl4 is formed by homogeneous crystal growth starting from the bulk region of the acetone sample.

  2. Effect of second harmonic in pulse-width-modulation-based DAC for feedback of digital fluxgate magnetometer

    Science.gov (United States)

    Belyayev, Serhiy; Ivchenko, Nickolay

    2018-04-01

    Digital fluxgate magnetometers employ processing of the measured pickup signal to produce the value of the compensation current. Using pulse-width modulation with filtering for digital to analog conversion is a convenient approach, but it can introduce an intrinsic source of nonlinearity, which we discuss in this design note. A code shift of one least significant bit changes the second harmonic content of the pulse train, which feeds into the pick-up signal chain despite the heavy filtering. This effect produces a code-dependent nonlinearity. This nonlinearity can be overcome by the specific design of the timing of the pulse train signal. The second harmonic is suppressed if the first and third quarters of the excitation period pulse train are repeated in the second and fourth quarters. We demonstrate this principle on a digital magnetometer, achieving a magnetometer noise level corresponding to that of the sensor itself.

  3. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film

    International Nuclear Information System (INIS)

    Vikram, S.

    1999-01-01

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation

  4. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film.

    Energy Technology Data Exchange (ETDEWEB)

    Vikram, S.

    1999-01-20

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation.

  5. Adjustable focus laser sheet module for generating constant maximum width sheets for use in optical flow diagnostics

    International Nuclear Information System (INIS)

    Hult, J; Mayer, S

    2011-01-01

    A general design of a laser light sheet module with adjustable focus is presented, where the maximum sheet width is preserved over a fixed region. In contrast, conventional focusing designs are associated with a variation in maximum sheet width with focal position. A four lens design is proposed here, where the first three lenses are employed for focusing, and the last for sheet expansion. A maximum sheet width of 1100 µm was maintained over a 50 mm long distance, for focal distances ranging from 75 to 500 mm, when a 532 nm laser beam with a beam quality factor M 2 = 29 was used for illumination

  6. Progressive changes in arch width from primary to early mixed dentition period: A longitudinal study

    OpenAIRE

    S Sangwan; H S Chawla; A Goyal; K Gauba; U Mohanty

    2011-01-01

    Objective: The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. Materials and Methods: A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier ...

  7. Search for Invisibly Decaying Higgs Bosons with Large Decay Width Using the OPAL Detector at LEP

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Anagnostu, G.; Anderson, K.J.; Asai, S.; Axen, D.; Bailey, I.; Barberio, E.; Bailari, T.; Barlow, R.J.; Batly, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brown, Robert M.; Burckhart, H.J.; Campana, S.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, D.G.; Ciocca, C.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Gagnon, P.; Gary, John William; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harel, A.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Herten, G.; Heuer, R.D.; Hill, J.C.; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanzaki, J.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kramer, T.; Krasznahorkay, A., Jr.; Krieger, P.; von Krogh, J.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, A.; Ludwig, J.; Mader, W.; Marcellini, S.; Martin, A.J.; Mashimo, T.; Mattig, Peter; McKenna, J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Meyer, N.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pilcher, J.E.; Pinfold, J.; Plane, D.E.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rossi, A.M.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schorner-Sadenius, T.; Schroder, M.; Schumacher, M.; Seuster, R.; Shears, T.G.; shen, B.C.; sherwood, P.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Stahl, A.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2007-01-01

    This paper describes a topological search for an invisibly decaying Higgs boson,H, produced via the Bjorken process (e+e- -> HZ). The analysis is based on data recorded using the OPAL detector at LEP at centre-of-mass energies from 183 to 209 GeV corresponding to a total integrated luminosity of 629pb-1. In the analysis only hadronic decays of the Z boson are considered. A scan over Higgs boson masses from 1 to 120 GeV and decay widths from 1 to 3000 GeV revealed no indication for a signal in the data. From a likelihood ratio of expected signal and Standard Model background we determine upper limits on cross-section times branching ratio to an invisible final state. For moderate Higgs boson decay widths, these range from about 0.07pb Mh = 60GeV) to 0.57pb (Mh = 114GeV). For decay widths above 200GeV the upper limits are of the order of 0.15pb. The results can be interpreted in general scenarios predicting a large invisible decay width of the Higgs boson. As an example we interpret the results in the so-called...

  8. Relationship between width of greater trochanters and width of iliac wings in tronchanteric bursitis.

    Science.gov (United States)

    Viradia, Neal K; Berger, Alex A; Dahners, Laurence E

    2011-09-01

    Trochanteric bursitis is a common disorder that is characterized by inflammation of the bursa, superficial to the greater trochanter of the femur, leading to pain in the lateral hip, and often occurs because of acute trauma or repetitive friction involving the iliotibial band, the greater trochanter, and the bursa. In the study reported here, we hypothesized that the increased incidence of bursitis may be the result of the increased prominence of the trochanter in relation to the wings of the iliac crest. Distances between the outermost edges of trochanters and iliac wings were measured in 202 patients from the University of North Carolina Health Care System-101 without a known diagnosis and 101 with a clinical diagnosis of trochanteric bursitis. To determine significance, t tests for nonpaired data were used. Mean (SD) difference between trochanter and iliac wing widths was 28 (20) mm in the group diagnosed with trochanteric bursitis and 17 (18) mm in the control group. The difference between the groups in this regard was significant (Pbursitis group and 1.05 (.06) in the control group. The difference between these groups was significant (Pbursitis.

  9. Evaluation of Ashwagandha in alcohol withdrawal syndrome

    Directory of Open Access Journals (Sweden)

    Ruby B

    2012-10-01

    Full Text Available Objective: To evaluate the effect of Ashwagandha (ASW in attenuation of alcohol withdrawal in ethanol withdrawal mice model. Methods: Alcohol dependence was induced in mice by the oral, once-daily administration of 10% v/v ethanol (2 g/kg for one week. Once the animals were withdrawn from alcohol, the efficacy of ASW (200mg/kg and 500mg/kg in comparison with diazepam (1 mg/kg in the attenuation of withdrawal was studied using, pentylenetetrazole (PTZ kindling test for seizure threshold, forced swim test (FST for depression and locomotor activity (LCA in open field test (OFT. 6 hours after the last ethanol administration, seizure threshold was measured in all the groups by administering the convulsant drug, PTZ with a subconvulsive dose of 30 mg/kg i.p. In FST, mice were forced to swim and the total duration of immobility (seconds was measured during the last 4 min of a single 6-min test session. In OFT, number of crossings of the lines marked on the floor was recorded for a period of 5 min. Results: Compared to ethanol group, ASW (500 mg/Kg has suppressed the PTZ kindling seizures in ethanol withdrawal animals [0% convulsion], FST has shown decreased immobility time and OFT has exhibited increase in the number of line crossing activity by mice which may be the consequence of anxiolytic activity of ASW similar to that of diazepam. Conclusions: The present study provides satisfactory evidence to use ASW as a safe and reliable alternative to diazepam in alcohol withdrawal conditions.

  10. Relationship Between Crack Growth Resistance KR Curve and Specimen Width for 2060 - T8E30 Lithium Aluminum Alloy

    Directory of Open Access Journals (Sweden)

    Tong Di Hua

    2016-01-01

    Full Text Available KR crack growth resistance curve can be used to predict crack propagation behavior, estimate the crack component bearing capacity after the crack, so KR curve research occupies very important position in the fracture mechanics. Based on crack growth resistance KR test curve of 2060 - T8E30 lithium aluminum alloy under the same thickness for different width, studies have shown that under the same thickness, the influence of the width on the resistance curve of crack propagation can be neglected. Empirical equation of resistance curve of crack extension of the smaller width specimen is given. Extending the fitting equation to that of larger width, it can be found that it is highly coincided with the experimental results.

  11. Progressive changes in arch width from primary to early mixed dentition period: A longitudinal study

    Directory of Open Access Journals (Sweden)

    S Sangwan

    2011-01-01

    Full Text Available Objective: The present study was conducted to evaluate, on a longitudinal basis, the changes in intercanine and intermolar widths form the primary to the early mixed dentition periods. Materials and Methods: A total of 38 children aged 4-5 years, with normal occlusion without any proximal caries or any dental anomalies, were selected. The impressions were recorded and casts were prepared. Intercanine and intermolar widths were measured on these dental casts with the help of a digital vernier calliper. After 3 years follow-up, the impressions were recorded again and dental casts were prepared. Intercanine and intermolar widths were measured again at this stage and were compared with the baseline data using the paired t-test and the chi square test. Results: There is a significant increase in the intercanine (3.93 + 1.70 mm and intermolar width (1.49 + 1.77 mm during the transition period from primary to early mixed dentition in both the arches and both the sexes. The gender-wise comparison showed a greater increase in males than in females, but this was not statistically significant. Conclusion: A thorough knowledge of growth changes during various stages of the mixed dentition period are important for a pediatric dentist to make an accurate diagnosis and treatment planning during preventive and interceptive orthodontics.

  12. Diffusion and Clustering of Carbon Dioxide on Non-porous Amorphous Solid Water

    Energy Technology Data Exchange (ETDEWEB)

    He, Jiao; Emtiaz, Shahnewaj M.; Vidali, Gianfranco, E-mail: jhe08@syr.edu, E-mail: gvidali@syr.edu [Physics Department, Syracuse University, Syracuse, NY 13244 (United States)

    2017-03-01

    Observations by ISO and Spitzer toward young stellar objects showed that CO{sub 2} segregates in the icy mantles covering dust grains. Thermal processing of the ice mixture was proposed as being responsible for the segregation. Although several laboratories studied thermally induced segregation, a satisfying quantification is still missing. We propose that the diffusion of CO{sub 2} along pores inside water ice is the key to quantify segregation. We combined Temperature Programmed Desorption and Reflection Absorption InfraRed Spectroscopy to study how CO{sub 2} molecules interact on a non-porous amorphous solid water (np-ASW) surface. We found that CO{sub 2} diffuses significantly on an np-ASW surface above 65 K and clusters are formed at well below one monolayer. A simple rate equation simulation finds that the diffusion energy barrier of CO{sub 2} on np-ASW is 2150 ± 50 K, assuming a diffusion pre-exponential factor of 10{sup 12} s{sup −1}. This energy should also apply to the diffusion of CO{sub 2} on the wall of pores. The binding energy of CO{sub 2} from CO{sub 2} clusters and CO{sub 2} from H{sub 2}O ice has been found to be 2415 ± 20 K and 2250 ± 20 K, respectively, assuming the same prefactor for desorption. CO{sub 2}–CO{sub 2} interaction is stronger than CO{sub 2}–H{sub 2}O interaction, in agreement with the experimental finding that CO{sub 2} does not wet the np-ASW surface. For comparison, we carried out similar experiments with CO on np-ASW, and found that the CO–CO interaction is always weaker than CO–H{sub 2}O. As a result, CO wets the np-ASW surface. This study should be of help to uncover the thermal history of CO{sub 2} on the icy mantles of dust grains.

  13. On the channel width-dependence of the thermal conductivity in ultra-narrow graphene nanoribbons

    Energy Technology Data Exchange (ETDEWEB)

    Karamitaheri, Hossein [Department of Electrical Engineering, University of Kashan, Kashan 87317-53153 (Iran, Islamic Republic of); Neophytou, Neophytos, E-mail: N.Neophytou@warwick.ac.uk [School of Engineering, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2016-08-08

    The thermal conductivity of low-dimensional materials and graphene nanoribbons, in particular, is limited by the strength of line-edge-roughness scattering. One way to characterize the roughness strength is the dependency of the thermal conductivity on the channel's width in the form W{sup β}. Although in the case of electronic transport, this dependency is very well studied, resulting in W{sup 6} for nanowires and quantum wells and W{sup 4} for nanoribbons, in the case of phonon transport it is not yet clear what this dependence is. In this work, using lattice dynamics and Non-Equilibrium Green's Function simulations, we examine the width dependence of the thermal conductivity of ultra-narrow graphene nanoribbons under the influence of line edge-roughness. We show that the exponent β is in fact not a single well-defined number, but it is different for different parts of the phonon spectrum depending on whether phonon transport is ballistic, diffusive, or localized. The exponent β takes values β < 1 for semi-ballistic phonon transport, values β ≫ 1 for sub-diffusive or localized phonons, and β = 1 only in the case where the transport is diffusive. The overall W{sup β} dependence of the thermal conductivity is determined by the width-dependence of the dominant phonon modes (usually the acoustic ones). We show that due to the long phonon mean-free-paths, the width-dependence of thermal conductivity becomes a channel length dependent property, because the channel length determines whether transport is ballistic, diffusive, or localized.

  14. The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts

    International Nuclear Information System (INIS)

    Van Kesteren, Z; Janssen, T M; Damen, E; Van Vliet-Vroegindeweij, C

    2012-01-01

    To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10 mm leaf width MLCs, with and without interdigitating leafs, and a 5 mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10 mm leaf width MLC with and without leaf interdigitation. When comparing the 10 mm leaf width MLC with the 5 mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V 95% was reduced by 0.02 using the thin MLC. The V 65% of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V 95% was equivalent for the 10 and 5 mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5 mm generates better treatment plans although the clinical relevance remains to be proven

  15. The dosimetric impact of leaf interdigitation and leaf width on VMAT treatment planning in Pinnacle: comparing Pareto fronts.

    Science.gov (United States)

    van Kesteren, Z; Janssen, T M; Damen, E; van Vliet-Vroegindeweij, C

    2012-05-21

    To evaluate in an objective way the effect of leaf interdigitation and leaf width on volumetric modulated arc therapy plans in Pinnacle. Three multileaf collimators (MLCs) were modeled: two 10 mm leaf width MLCs, with and without interdigitating leafs, and a 5 mm leaf width MLC with interdigitating leafs. Three rectum patients and three prostate patients were used for the planning study. In order to compare treatment techniques in an objective way, a Pareto front comparison was carried out. 200 plans were generated in an automated way, per patient per MLC model, resulting in a total of 3600 plans. From these plans, Pareto-optimal plans were selected which were evaluated for various dosimetric variables. The capability of leaf interdigitation showed little dosimetric impact on the treatment plans, when comparing the 10 mm leaf width MLC with and without leaf interdigitation. When comparing the 10 mm leaf width MLC with the 5 mm leaf width MLC, both with interdigitating leafs, improvement in plan quality was observed. For both patient groups, the integral dose was reduced by 0.6 J for the thin MLC. For the prostate patients, the mean dose to the anal sphincter was reduced by 1.8 Gy and the conformity of the V(95%) was reduced by 0.02 using the thin MLC. The V(65%) of the rectum was reduced by 0.1% and the dose homogeneity with 1.5%. For rectum patients, the mean dose to the bowel was reduced by 1.4 Gy and the mean dose to the bladder with 0.8 Gy for the thin MLC. The conformity of the V(95%) was equivalent for the 10 and 5 mm leaf width MLCs for the rectum patients. We have objectively compared three types of MLCs in a planning study for prostate and rectum patients by analyzing Pareto-optimal plans which were generated in an automated way. Interdigitation of MLC leafs does not generate better plans using the SmartArc algorithm in Pinnacle. Changing the MLC leaf width from 10 to 5 mm generates better treatment plans although the clinical relevance remains

  16. Interference in the gg→h→γγ On-Shell Rate and the Higgs Boson Total Width.

    Science.gov (United States)

    Campbell, John; Carena, Marcela; Harnik, Roni; Liu, Zhen

    2017-11-03

    We consider interference between the Higgs signal and QCD background in gg→h→γγ and its effect on the on-shell Higgs rate. The existence of sizable strong phases leads to destructive interference of about 2% of the on-shell cross section in the standard model. This effect can be enhanced by beyond the standard model physics. In particular, since it scales differently from the usual rates, the presence of interference allows indirect limits to be placed on the Higgs width in a novel way, using on-shell rate measurements. Our study motivates further QCD calculations to reduce uncertainties. We discuss possible width-sensitive observables, both using total and differential rates and find that the HL-LHC can potentially indirectly constrain widths of order tens of MeV.

  17. Temperature dependence of spreading width of giant dipole resonance

    International Nuclear Information System (INIS)

    Storozhenko, A.N.; Vdovin, A.I.; Ventura, A.; Blokhin, A.I.

    2002-01-01

    The Quasiparticle-Phonon Nuclear Model extended to finite temperature within the framework of Thermo Field Dynamics is applied to calculate a temperature dependence of the spreading width Γ ↓ of a giant dipole resonance. Numerical calculations are made for 120 Sn and 208 Pb nuclei. It is found that Γ ↓ increases with T. The reason of this effect is discussed as well as a relation of the present approach to other ones, existing in the literature

  18. Radiographic reference limits for cardiac width in peregrine falcons (Falco peregrinus)

    NARCIS (Netherlands)

    Lumeij, J.T.; Shaik, S.; Ali, M.

    2011-01-01

    Abstract Journal of the American Veterinary Medical Association June 1, 2011, Vol. 238, No. 11, Pages 1459-1463 doi: 10.2460/javma.238.11.1459 Radiographic reference limits for cardiac width in peregrine falcons (Falco peregrinus) Johannes T. Lumeij, DVM, PhD; Muneer A. S. Shaik, BVSc, AH; Mohammed

  19. Measuring ventricular width on cranial computed tomography. Feasibility of dose reduction in a custom-made adult phantom

    Energy Technology Data Exchange (ETDEWEB)

    Daubner, D.; Cerhova, J.; Linn, J. [Dresden Univ. (Germany). Dept. of Neuroradiology; Spieth, S. [Dresden Univ. (Germany). Dept. of Radiology; Kirchhof, K. [Chemnitz Hospital (Germany). Dept. of Diagnostic and Interventional Radiology and Neuradiology

    2016-01-15

    To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80 kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140 kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5 mm from the reference values. A maximum score of 4 could be achieved. The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140 kV, the dose can be reduced by 76 % for LightSpeed Ultra and by 80 % for Somatom Sensation provided that a margin of error of 37.5 % (score = 2.5) for correct width measurement of the carrots is accepted. Lowering the radiation dose by up to 48 % for LightSpeed Ultra and by 52 % for Somatom Sensation, compared to the standard protocol (120 kV and 400 mA) still allowed reliable measurements of ventricular widths in this model.

  20. Measuring ventricular width on cranial computed tomography. Feasibility of dose reduction in a custom-made adult phantom

    International Nuclear Information System (INIS)

    Daubner, D.; Cerhova, J.; Linn, J.; Spieth, S.; Kirchhof, K.

    2016-01-01

    To estimate feasible dose reduction to reliably measure ventricular width in adults with hydrocephalus in follow-up cranial computed tomography (CCT) using a custom-made phantom. A gelatine-filled adult calvarium with embedded central fibers of two carrots representing the lateral ventricles was used as a phantom. The phantom was scanned 11 times with two CT scanners (LightSpeed Ultra, GE and Somatom Sensation, Siemens), using tube currents of 380/400, 350, 300, 250, 200, 150 and 100 mA, and tube voltages of 140, 120, 100 and 80 kV. The width of the carrots was measured at four sites in consensus decision of two principle investigators blinded to the scan parameters. Values measured at 380/400 mA and 140 kV served as a reference for the width of the ventricles. Measurements received 1 point if they did not differ more than 0.5 mm from the reference values. A maximum score of 4 could be achieved. The relationship between the correct width measurement of the carrots (lateral ventricles) and the radiation dose can be described by a quadratic regression function. Pixel noise increases and accuracy of measurements decreases with a lower radiation dose. Starting from a tube current of 380/400 mA and a tube voltage of 140 kV, the dose can be reduced by 76 % for LightSpeed Ultra and by 80 % for Somatom Sensation provided that a margin of error of 37.5 % (score = 2.5) for correct width measurement of the carrots is accepted. Lowering the radiation dose by up to 48 % for LightSpeed Ultra and by 52 % for Somatom Sensation, compared to the standard protocol (120 kV and 400 mA) still allowed reliable measurements of ventricular widths in this model.

  1. Progress towards modeling tokamak boundary plasma turbulence and understanding its role in setting divertor heat flux widths

    Science.gov (United States)

    Chen, Bin

    2017-10-01

    QCMs (quasi-coherent modes) are well characterized in the edge of Alcator C-Mod, when operating in the Enhanced Dα (EDA) H-mode, a promising alternative regime for ELM (edge localized modes) suppressed operation. To improve the understanding of the physics behind the QCMs, three typical C-Mod EDA H-Mode discharges are simulated by BOUT + + using a six-field two-fluid model (based on the Braginskii equations). The simulated characteristics of the frequency versus wave number spectra of the modes is in reasonable agreement with phase contrast imaging data. The key simulation results are: 1) Linear spectrum analysis and the nonlinear phase relationship indicate the dominance of resistive-ballooning modes and drift-Alfven wave instabilities; 2) QCMs originate inside the separatrix; (3) magnetic flutter causes the mode spreading into the SOL; 4) the boundary electric field Er changes the turbulent characteristics of the QCMs and controls edge transport and the divertor heat flux width; 5) the magnitude of the divertor heat flux depends on the physics models, such as sources and sinks, sheath boundary conditions, and parallel heat flux limiting coefficient. The BOUT + + simulations have also been performed for inter-ELM periods of DIII-D and EAST discharges, and similar quasi-coherent modes have been found. The parallel electron heat fluxes projected onto the target from these BOUT + + simulations follow the experimental heat flux width scaling, in particular the inverse dependence of the width on the poloidal magnetic field with an outlier. Further turbulence statistics analysis shows that the blobs are generated near the pedestal peak gradient region inside the separatrix and contribute to the transport of the particle and heat in the SOL region. To understand the Goldston heuristic drift-based model, results will also be presented from self-consistent transport simulations with the electric and magnetic drifts in BOUT + + and with the sheath potential included in the

  2. Femtosecond Laser--Pumped Source of Entangled Photons for Quantum Cryptography Applications

    International Nuclear Information System (INIS)

    Pan, D.; Donaldson, W.; Sobolewski, R.

    2007-01-01

    We present an experimental setup for generation of entangled-photon pairs via spontaneous parametric down-conversion, based on the femtosecond-pulsed laser. Our entangled-photon source utilizes a 76-MHz-repetition-rate, 100-fs-pulse-width, mode-locked, ultrafast femtosecond laser, which can produce, on average, more photon pairs than a cw laser of an equal pump power. The resulting entangled pairs are counted by a pair of high-quantum-efficiency, single-photon, silicon avalanche photodiodes. Our apparatus s intended as an efficient source/receiver system for the quantum communications and quantum cryptography applications

  3. The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images

    International Nuclear Information System (INIS)

    Roh, Yang Gyun; Jang, Hyun Seon; Kim, Byung Ock; Kim, Jin Soo

    2006-01-01

    To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1. The statistical analyses were carried out using SPSS 12.0.1. When the maxillary central incisors remained, the mean labial alveolar bone width were 6.81±1.41 mm, 6.46±1.33 mm, and 7.91±1.33 mm. When the maxillary central incisors were missed the mean width were 5.42±2.20 mm, 6.23±2.29 mm, and 7.89±2.13 mm. The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to masal cavity revealed statistically significant difference (P<0.05)

  4. The Effect of Crack Width on Chloride-Induced Corrosion of Steel in Concrete

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2017-01-01

    Full Text Available When subjected to loading or thermal shrinkage, reinforced concrete structures usually behave in a cracking state, which raises the risk of bar corrosion from the working environment. The influence of cover cracking on chloride-induced corrosion was experimentally investigated through a 654-day laboratory test on cracked reinforced concrete specimens exposed to chloride solution. The concrete specimens have a dimension of 100 mm × 100 mm × 400 mm and a single prefabricated crack at the midspan. When the percentage concentration of chloride ion (0.6%, 1.2%, 2.1%, 3.0%, and 6.0% and crack width (uncracked, 0.2, 0.3, 0.4, and 0.5 mm are taken as variables, the experimental results showed that the corrosion rates for cracked specimens increased with increasing percentage concentration of chloride and increasing crack width. This study also showed the interrelationship between crack width and percentage concentration of chloride on the corrosion rate. In addition, an empirical model, incorporating the influence of the cover cracking and chloride concentration, was developed to predict the corrosion rate. This model allows the prediction of the maximum allowable wcr based on the given percentage concentration of chloride in the exposure condition.

  5. A correction for emittance-measurement errors caused by finite slit and collector widths

    International Nuclear Information System (INIS)

    Connolly, R.C.

    1992-01-01

    One method of measuring the transverse phase-space distribution of a particle beam is to intercept the beam with a slit and measure the angular distribution of the beam passing through the slit using a parallel-strip collector. Together the finite widths of the slit and each collector strip form an acceptance window in phase space whose size and orientation are determined by the slit width, the strip width, and the slit-collector distance. If a beam is measured using a detector with a finite-size phase-space window, the measured distribution is different from the true distribution. The calculated emittance is larger than the true emittance, and the error depends both on the dimensions of the detector and on the Courant-Snyder parameters of the beam. Specifically, the error gets larger as the beam drifts farther from a waist. This can be important for measurements made on high-brightness beams, since power density considerations require that the beam be intercepted far from a waist. In this paper we calculate the measurement error and we show how the calculated emittance and Courant-Snyder parameters can be corrected for the effects of finite sizes of slit and collector. (Author) 5 figs., 3 refs

  6. Width design for gobs and isolated coal pillars based on overall burst-instability prevention in coal mines

    Directory of Open Access Journals (Sweden)

    Junfei Zhang

    2016-08-01

    Full Text Available An investigation was conducted on the overall burst-instability of isolated coal pillars by means of the possibility index diagnosis method (PIDM. First, the abutment pressure calculation model of the gob in side direction was established to derive the abutment pressure distribution curve of the isolated coal pillar. Second, the overall burst-instability ratio of the isolated coal pillars was defined. Finally, the PIDM was utilized to judge the possibility of overall burst-instability and recoverability of isolated coal pillars. The results show that an overall burst-instability may occur due to a large gob width or a small pillar width. If the width of the isolated coal pillar is not large enough, the shallow coal seam will be damaged at first, and then the high abutment pressure will be transferred to the deep coal seam, which may cause an overall burst-instability accident. This approach can be adopted to design widths of gobs and isolated coal pillars and to evaluate whether an existing isolated coal pillar is recoverable in skip-mining mines.

  7. Self-absorption and self-scattering in emitter source of alpha particles

    International Nuclear Information System (INIS)

    Terini, R.A.

    1990-01-01

    This paper describes preliminary results on spectrometric analysis and activity measurements of alpha-emitting sources prepared by evaporation on mylar. The measurements were made with a Si surface barrier detector. By the analysis of the angular distribuition of the alpha particles emitted, it was possible to observe that the width of the spectrum low energy tail increases with the emission angle θ, due to the energy degradation in the source material, which affects the measured particles energy. The source activity was also measured from detection solid angles of approx. 10 -1 and aprox. 10 -3 Sr, as a function of θ. The absolute activity of the alpha source was determined and a discussion is present on the ideal conditions necessary for such measurements. (author) [pt

  8. Calculation of decay widths of pp{mu}{sub {nu}}{sub ,J}{sup *} ion in non-adiabatic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gheisari, R. [Persian Gulf Univ., Physics Dept., Bushehr (Iran, Islamic Republic of)

    2009-06-15

    We calculate decay widths of the metastable pp{mu}{sub {nu}}{sub ,J}{sup *} molecular ion in non-adiabatic approach. The muonic molecular ion can be formed in collision of the excited p{mu}(2s) atoms with H{sub 2}. Then, the decay of the pp{mu}{sub {nu}}{sub ,J}{sup *} system opens a path for the muon from p{mu}(2s) to p{mu}(1s). We employ trial wave function which includes non-adiabatic terms to calculate some radiationless decay widths. The present results of the widths do not agree well with those given in our previous work, however they are more close to recent data of other researchers. (author)

  9. Manipulating the retrieved width of stored light pulses

    International Nuclear Information System (INIS)

    Chen Yongfan; Wang Shihhao; Wang Changyi; Yu, Ite A.

    2005-01-01

    We have systematically studied the method proposed by Patnaik et al. [Phys. Rev. A 69, 035803 (2004)] that manipulates the retrieval of stored light pulses. The measured probe pulse width of the retrieval is inversely proportional to the intensity of the reading field. We also show that the method does not introduce any phase shift or jump into the retrieved pulses. Our study demonstrates that the distortion at the output of the light storage can be corrected by manipulating the retrieval process and the phase information of the stored pulses can remain intact during the process

  10. Development of negative heavy ion sources for plasma potential measurement

    International Nuclear Information System (INIS)

    Sasao, M.; Okabe, Y.; Fujisawa, A.; Iguchi, H.; Fujita, J.; Yamaoka, H.; Wada, M.

    1991-10-01

    A plasma sputter negative ion source was studied for its applicability to the potential measurement of a fusion plasma. Both the beam current density and the beam energy spread are key issues. Energy spectra of a self extracted Au - beam from the source were measured under the condition of a constant work function of the production surface. The full width of half maximum (FWHM) increases from 3 eV to 9 eV monotonically as the target voltage increases from 50 V to 300 V, independently from the target surface work function of 2.2 - 3 eV. (author)

  11. Is biologic width of anterior and posterior teeth similar?

    Directory of Open Access Journals (Sweden)

    Amir Alireza Rasouli Ghahroudi

    2014-09-01

    Full Text Available The biologic width (BW includes attached epithelial cells and connective tissue attachment complex being very important in the periodontal health during prosthetic treatments as invading this zone can cause bone resorption and gingival recession. The present study investigated biologic width values in the normal periodontium in anterior and posterior teeth. 30 patients that referred from restorative department to periodontics department of Tehran University of medical sciences who need crown lengthening procedure on their teeth with no history of orthodontic, prosthodontic and periodontal treatment were randomly enrolled in this cross-sectional trial. Sulcus depths (SD as well as the distance between free gingival margin and the bone crest (FB of anterior and posterior teeth were measured by UNC-15 probe and compared. periodontium thickness was also assessed. The data were subjected to Student t test. Mean BW in the 43 anterior and 47 posterior teeth was measured and not significantly different (1.4651±0.39 mm vs. 1.6312±0.49 mm was observed; however, BW was significantly more in the teeth with thick periodontium compared to those with thin periodontium (1.703±0.5 vs. 1.408±0.35; P=0.002. BW not only is different in individuals but also could be dissimilar in different teeth and should be calculated independently prior to restorative treatments.

  12. Probing the critical behavior in the evolution of GDR width at very low temperatures in A∼100 mass region

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Balaram; Mondal, Debasish; Pandit, Deepak; Mukhopadhyay, S.; Pal, Surajit [Variable Energy Cyclotron Centre, 1/AF-Bidhannagar, Kolkata 700064 (India); Bhattacharya, Srijit [Department of Physics, Barasat Govt. College, Barasat, N 24 Pgs, Kolkata 700124 (India); De, A. [Department of Physics, Raniganj Girls' College, Raniganj 713358 (India); Banerjee, K. [Variable Energy Cyclotron Centre, 1/AF-Bidhannagar, Kolkata 700064 (India); Dinh Dang, N. [Theoretical Nuclear Physics Laboratory, RIKEN Nishina Center for Accelerator-Based Science, RIKEN, 2-1 Hirosawa, Wako city, Saitama 351-0198 (Japan); Quang Hung, N. [School of Engineering, Tan Tao University, Tan Tao University Avenue, Tan Duc Ecity, Duc Hoa, Long An Province (Viet Nam); Banerjee, S.R., E-mail: srb@vecc.gov.in [Variable Energy Cyclotron Centre, 1/AF-Bidhannagar, Kolkata 700064 (India)

    2014-04-04

    The influence of giant dipole resonance (GDR) induced quadrupole moment on GDR width at low temperatures is investigated experimentally by measuring GDR width systematically in the unexplored temperature range T=0.8–1.5 MeV, for the first time, in A∼100 mass region. The measured GDR widths, using alpha induced fusion reaction, for {sup 97}Tc confirm that the GDR width remains constant at the ground state value up to a critical temperature and increases sharply thereafter with increase in T. The data have been compared with the adiabatic Thermal Shape Fluctuation Model (TSFM), phenomenological Critical Temperature Fluctuation Model (CTFM) and microscopic Phonon Damping Model (PDM). Interestingly, CTFM and PDM give similar results and agree with the data, whereas the TSFM differs significantly even after incorporating the shell effects.

  13. Probing the critical behavior in the evolution of GDR width at very low temperatures in A∼100 mass region

    International Nuclear Information System (INIS)

    Dey, Balaram; Mondal, Debasish; Pandit, Deepak; Mukhopadhyay, S.; Pal, Surajit; Bhattacharya, Srijit; De, A.; Banerjee, K.; Dinh Dang, N.; Quang Hung, N.; Banerjee, S.R.

    2014-01-01

    The influence of giant dipole resonance (GDR) induced quadrupole moment on GDR width at low temperatures is investigated experimentally by measuring GDR width systematically in the unexplored temperature range T=0.8–1.5 MeV, for the first time, in A∼100 mass region. The measured GDR widths, using alpha induced fusion reaction, for 97 Tc confirm that the GDR width remains constant at the ground state value up to a critical temperature and increases sharply thereafter with increase in T. The data have been compared with the adiabatic Thermal Shape Fluctuation Model (TSFM), phenomenological Critical Temperature Fluctuation Model (CTFM) and microscopic Phonon Damping Model (PDM). Interestingly, CTFM and PDM give similar results and agree with the data, whereas the TSFM differs significantly even after incorporating the shell effects.

  14. Gaussian width bounds with applications to arithmetic progressions in random settings

    NARCIS (Netherlands)

    J. Briët (Jop); S. Gopi (Sivakanth)

    2017-01-01

    textabstractMotivated by two problems on arithmetic progressions (APs)—concerning large deviations for AP counts in random sets and random differences in Szemer´edi’s theorem— we prove upper bounds on the Gaussian width of the image of the n-dimensional Boolean hypercube under a mapping ψ : Rn →

  15. Study of the spectral width of intermode beats and optical spectrum of an actively mode-locked three-mirror semiconductor laser

    International Nuclear Information System (INIS)

    Zakharyash, Valerii F; Kashirsky, Aleksandr V; Klementyev, Vasilii M; Kuznetsov, Sergei A; Pivtsov, V S

    2005-01-01

    Various oscillation regimes of an actively mode-locked semiconductor laser are studied experimentally. Two types of regimes are found in which the minimal spectral width (∼3.5 kHz) of intermode beats is achieved. The width of the optical spectrum of modes is studied as a function of their locking and the feedback coefficients. The maximum width of the spectrum is ∼3.7 THz. (control of laser radiation parameters)

  16. P-wave pulse analysis to retrieve source and propagation effects in the case of Vrancea earthquakes

    International Nuclear Information System (INIS)

    Popescu, E.; Popa, M.; Placinta, A.; Grecu, B.; Radulian, M.

    2004-01-01

    Seismic source parameters and attenuation structure properties are obtained from the first P-wave pulse analysis and empirical Green's function deconvolution. The P pulse characteristics are combined effects of source and path properties. To reproduce the real source and structure parameters it is crucial to apply a method able to distinguish between the different factors affecting the observed seismograms. For example the empirical Green's function deconvolution method (Hartzell, 1978) allows the retrieval of the apparent source time function or source spectrum corrected for path, site and instrumental effects. The apparent source duration is given by the width of the deconvoluted source pulse and is directly related to the source dimension. Once the source time function established, next we can extract the parameters related to path effects. The difference between the pulse recorded at a given station and the source pulse obtained by deconvolution is a measure of the attenuation along the path from focus to the station. On the other hand, the pulse width variations with azimuth depend critically on the fault plane orientation and source directivity. In favourable circumstances (high signal/noise ratio, high resolution and station coverage), the method of analysis proposed in this paper allows the constraint of the rupture plane among the two nodal planes characterizing the fault plane solution, even for small events. P-wave pulse analysis was applied for 25 Vrancea earthquakes recorded between 1999 and 2003 by the Romanian local network to determine source parameters and attenuation properties. Our results outline high-stress drop seismic energy release with relatively simple rupture process for the considered events and strong lateral variation of attenuation of seismic waves across Carpathians Arc. (authors)

  17. The optimal on-source region size for detections with counting-type telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Klepser, Stefan

    2017-01-15

    The on-source region is typically a circular area with radius θ in which the signal is expected to appear with the shape of the instrument point spread function (PSF). This paper addresses the question of what is the θ that maximises the probability of detection for a given PSF width and background event density. In the high count number limit and assuming a Gaussian PSF profile, the optimum is found to be at ζ{sup 2}{sub ∞}∼2.51 times the squared PSF width σ{sup 2}{sub PSF39}. While this number is shown to be a good choice in many cases, a dynamic formula for cases of lower count numbers, which favour larger on-source regions, is given. The recipe to get to this parametrisation can also be applied to cases with a non-Gaussian PSF. This result can standardise and simplify analysis procedures, reduce trials and eliminate the need for experience-based ad hoc cut definitions or expensive case-by-case Monte Carlo simulations.

  18. The optimal on-source region size for detections with counting-type telescopes

    International Nuclear Information System (INIS)

    Klepser, Stefan

    2017-01-01

    The on-source region is typically a circular area with radius θ in which the signal is expected to appear with the shape of the instrument point spread function (PSF). This paper addresses the question of what is the θ that maximises the probability of detection for a given PSF width and background event density. In the high count number limit and assuming a Gaussian PSF profile, the optimum is found to be at ζ"2_∞∼2.51 times the squared PSF width σ"2_P_S_F_3_9. While this number is shown to be a good choice in many cases, a dynamic formula for cases of lower count numbers, which favour larger on-source regions, is given. The recipe to get to this parametrisation can also be applied to cases with a non-Gaussian PSF. This result can standardise and simplify analysis procedures, reduce trials and eliminate the need for experience-based ad hoc cut definitions or expensive case-by-case Monte Carlo simulations.

  19. Direct measurement of the W boson width

    Energy Technology Data Exchange (ETDEWEB)

    Abazov, V.M.; /Dubna, JINR; Abbott, B.; /Oklahoma U.; Abolins, M.; /Michigan State U.; Acharya, B.S.; /Tata Inst.; Adams, M.; /Illinois U., Chicago; Adams, T.; /Florida State U.; Aguilo, E.; /Alberta U. /Simon Fraser U. /McGill U.; Ahsan, M.; /Kansas State U.; Alexeev, G.D.; /Dubna, JINR; Alkhazov, G.; /St. Petersburg, INP; Alton, A.; /Michigan U. /Northeastern U.

    2009-09-01

    We present a direct measurement of the width of the W boson using the shape of the transverse mass distribution of W {yields} e{nu} candidates selected in 1 fb{sup -1} of data collected with the D0 detector at the Fermilab Tevatron collider in p{bar p} collisions at {radical}s = 1.96 TeV. We use the same methods and data sample that were used for our recently published W boson mass measurement, except for the modeling of the recoil, which is done with a new method based on a recoil library. Our result, 2.028 {+-} 0.072 GeV, is in agreement with the predictions of the standard model and is the most precise direct measurement result from a single experiment to date.

  20. Compound refractive lenses for novel X-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Piestrup, M.A. E-mail: melpie@adelphitech.com; Beguiristain, H.R.; Gary, C.K.; Cremer, J.T.; Pantell, R.H.; Tatchyn, R

    2001-01-01

    We have measured the intensity profile of X-rays focused by a linear array of closely spaced spherical lenses fabricated using Mylar (C{sub 5}H{sub 4}O{sub 2}). We have experimentally demonstrated that we can achieve two-dimensional focusing for photon energies between 7 and 9 keV with imaging distances of less than 1 m. For example, using 8-keV X-rays we have achieved full-width-at-half-maximum (FWHM) linewidths down to 27.5 {mu}m at a distance of only 62 cm from the lens. The effective aperture of the lens was measured to be about 390 {mu}m with 38% transmission at 9 keV. A synchrotron source having source-size dimensions of 0.44x1.7 mm{sup 2} was utilized for the experimental work. Such lenses are seen as useful for focusing and increasing the intensity of novel X-ray sources that are directional and have small source size ({sigma}<1 mm)