WorldWideScience

Sample records for source parameter study

  1. Investigation on Ion Source Parameters

    CERN Document Server

    M. Cheikh Mhamed, S. Essabaa, C. Lau

    The EURISOL multi-mega-watt target station requires dedicated radioactive ion sources. Notably, they must be capable of operating under extremely hard radiations and with a larger fission target producing over 1014 fissions/s. The realisation of next-generation ion sources suitable for such operating conditions needs exhaustive studies and developments. In order to take up such a challenge, a review on radioactive ion sources was achieved and the investigation on ion source parameters was in particular focused on a plasma ion source through a R&D program.

  2. Design parameters and source terms: Volume 3, Source terms

    International Nuclear Information System (INIS)

    1987-10-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report by Stearns Catalytic Corporation (SCC), entitled ''Design Parameters and Source Terms for a Two-Phase Repository in Salt,'' 1985, to the level of the Site Characterization Plan - Conceptual Design Report. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible Salt Repository sites. 11 refs., 9 tabs

  3. Estimation of source parameters of Chamoli Earthquake, India

    Indian Academy of Sciences (India)

    R. Narasimhan, Krishtel eMaging Solutions

    meter studies, in different parts of the world. Singh et al (1979) and Sharma and Wason (1994, 1995) have calculated source parameters for Himalayan and nearby regions. To the best of this authors' knowledge, the source parameter studies using strong motion data have not been carried out in India so far, though similar ...

  4. Design parameters and source terms: Volume 1, Design parameters: Revision 0

    International Nuclear Information System (INIS)

    1987-10-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report by Stearns Catalytic Corporation (SCC), entitled ''Design Parameters and Source Terms for a Two-Phase Repository in Salt,'' 1985, to the level of the Site Characterization Plan - Conceptual Design Report. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible Salt Repository sites

  5. Noise disturbance in open-plan study environments: a field study on noise sources, student tasks and room acoustic parameters.

    Science.gov (United States)

    Braat-Eggen, P Ella; van Heijst, Anne; Hornikx, Maarten; Kohlrausch, Armin

    2017-09-01

    The aim of this study is to gain more insight in the assessment of noise in open-plan study environments and to reveal correlations between noise disturbance experienced by students and the noise sources they perceive, the tasks they perform and the acoustic parameters of the open-plan study environment they work in. Data were collected in five open-plan study environments at universities in the Netherlands. A questionnaire was used to investigate student tasks, perceived sound sources and their perceived disturbance, and sound measurements were performed to determine the room acoustic parameters. This study shows that 38% of the surveyed students are disturbed by background noise in an open-plan study environment. Students are mostly disturbed by speech when performing complex cognitive tasks like studying for an exam, reading and writing. Significant but weak correlations were found between the room acoustic parameters and noise disturbance of students. Practitioner Summary: A field study was conducted to gain more insight in the assessment of noise in open-plan study environments at universities in the Netherlands. More than one third of the students was disturbed by noise. An interaction effect was found for task type, source type and room acoustic parameters.

  6. Design parameters and source terms: Volume 2, Source terms: Revision 0

    International Nuclear Information System (INIS)

    1987-10-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report by Stearns Catalytic Corporation (SCC), entitled ''Design Parameters and Source Terms for a Two-Phase Repository Salt,'' 1985, to the level of the Site Characterization Plan - Conceptual Design Report. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible Salt Repository sites. 2 tabs

  7. Delineation of seismic source zones based on seismicity parameters ...

    Indian Academy of Sciences (India)

    In the present study, an attempt has been made to delineate seismic source zones in the study area (south India) based on the seismicity parameters. Seismicity parameters and the maximum probable earthquake for these source zones were evaluated and were used in the hazard evaluation. The probabilistic evaluation of ...

  8. The primary ion source for construction and optimization of operation parameters

    International Nuclear Information System (INIS)

    Synowiecki, A.; Gazda, E.

    1986-01-01

    The construction of primary ion source for SIMS has been presented. The influence of individual operation parameters on the properties of ion source has been investigated. Optimization of these parameters has allowed to appreciate usefulness of the ion source for SIMS study. 14 refs., 8 figs., 2 tabs. (author)

  9. Global Source Parameters from Regional Spectral Ratios for Yield Transportability Studies

    Science.gov (United States)

    Phillips, W. S.; Fisk, M. D.; Stead, R. J.; Begnaud, M. L.; Rowe, C. A.

    2016-12-01

    We use source parameters such as moment, corner frequency and high frequency rolloff as constraints in amplitude tomography, ensuring that spectra of well-studied earthquakes are recovered using the ensuing attenuation and site term model. We correct explosion data for path and site effects using such models, which allows us to test transportability of yield estimation techniques based on our best source spectral estimates. To develop a background set of source parameters, we applied spectral ratio techniques to envelopes of a global set of regional distance recordings from over 180,000 crustal events. Corner frequencies and moment ratios were determined via inversion using all event pairs within predetermined clusters, shifting to absolute levels using independently determined regional and teleseismic moments. The moment and corner frequency results can be expressed as stress drop, which has considerable scatter, yet shows dramatic regional patterns. We observe high stress in subduction zones along S. America, S. Mexico, the Banda Sea, and associated with the Yakutat Block in Alaska. We also observe high stress at the Himalayan syntaxes, the Pamirs, eastern Iran, the Caspian, the Altai-Sayan, and the central African rift. Low stress is observed along mid ocean spreading centers, the Afar rift, patches of convergence zones such as Nicaragua, the Zagros, Tibet, and the Tien Shan, among others. Mine blasts appear as low stress events due to their low corners and steep rolloffs. Many of these anomalies have been noted by previous studies, and we plan to compare results directly. As mentioned, these results will be used to constrain tomographic imaging, but can also be used in model validation procedures similar to the use of ground truth in location problems, and, perhaps most importantly, figure heavily in quality control of local and regional distance amplitude measurements.

  10. Design parameters and source terms: Volume 2, Source terms: Revision 0

    International Nuclear Information System (INIS)

    1987-09-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report to the level of the Site Characterization Plan---Conceptual Design Report SCP-CDR. The previous study identifies the data needs for the Environmental Assessment effort for seven possible salt repository sites. Volume 2 contains tables of source terms

  11. The Exponent of High-frequency Source Spectral Falloff and Contribution to Source Parameter Estimates

    Science.gov (United States)

    Kiuchi, R.; Mori, J. J.

    2015-12-01

    As a way to understand the characteristics of the earthquake source, studies of source parameters (such as radiated energy and stress drop) and their scaling are important. In order to estimate source parameters reliably, often we must use appropriate source spectrum models and the omega-square model is most frequently used. In this model, the spectrum is flat in lower frequencies and the falloff is proportional to the angular frequency squared. However, Some studies (e.g. Allmann and Shearer, 2009; Yagi et al., 2012) reported that the exponent of the high frequency falloff is other than -2. Therefore, in this study we estimate the source parameters using a spectral model for which the falloff exponent is not fixed. We analyze the mainshock and larger aftershocks of the 2008 Iwate-Miyagi Nairiku earthquake. Firstly, we calculate the P wave and SH wave spectra using empirical Green functions (EGF) to remove the path effect (such as attenuation) and site effect. For the EGF event, we select a smaller earthquake that is highly-correlated with the target event. In order to obtain the stable results, we calculate the spectral ratios using a multitaper spectrum analysis (Prieto et al., 2009). Then we take a geometric mean from multiple stations. Finally, using the obtained spectra ratios, we perform a grid search to determine the high frequency falloffs, as well as corner frequency of both of events. Our results indicate the high frequency falloff exponent is often less than 2.0. We do not observe any regional, focal mechanism, or depth dependencies for the falloff exponent. In addition, our estimated corner frequencies and falloff exponents are consistent between the P wave and SH wave analysis. In our presentation, we show differences in estimated source parameters using a fixed omega-square model and a model allowing variable high-frequency falloff.

  12. Noise disturbance in open-plan study environments : a field study on noise sources, student tasks and room acoustic parameters

    NARCIS (Netherlands)

    Braat-Eggen, P.E.; van Heijst, A.W.M.; Hornikx, M.C.J.; Kohlrausch, A.G.

    2017-01-01

    The aim of this study is to gain more insight in the assessment of noise in open-plan study environments and to reveal correlations between noise disturbance experienced by students and the noise sources they perceive, the tasks they perform and the acoustic parameters of the open-plan study

  13. Kinetic parameters for source driven systems

    International Nuclear Information System (INIS)

    Dulla, S.; Ravetto, P.; Carta, M.; D'Angelo, A.

    2006-01-01

    The definition of the characteristic kinetic parameters of a subcritical source-driven system constitutes an interesting problem in reactor physics with important consequences for practical applications. Consistent and physically meaningful values of the parameters allow to obtain accurate results from kinetic simulation tools and to correctly interpret kinetic experiments. For subcritical systems a preliminary problem arises for the adoption of a suitable weighting function to be used in the projection procedure to derive a point model. The present work illustrates a consistent factorization-projection procedure which leads to the definition of the kinetic parameters in a straightforward manner. The reactivity term is introduced coherently with the generalized perturbation theory applied to the source multiplication factor ks, which is thus given a physical role in the kinetic model. The effective prompt lifetime is introduced on the assumption that a neutron generation can be initiated by both the fission process and the source emission. Results are presented for simplified configurations to fully comprehend the physical features and for a more complicated highly decoupled system treated in transport theory. (authors)

  14. Design parameters and source terms: Volume 1, Design parameters: Revision 0

    International Nuclear Information System (INIS)

    1987-09-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report to the level of the Site Characterization Plan - Conceptual Design Report, SCP-CDR. The previous unpublished SCC Study identified the data needs for the Environmental Assessment effort for seven possible salt repository sites

  15. Design parameters and source terms: Volume 3, Source terms: Revision 0

    International Nuclear Information System (INIS)

    1987-09-01

    The Design Parameters and Source Terms Document was prepared in accordance with DOE request and to provide data for the environmental impact study to be performed in the future for the Deaf Smith County, Texas site for a nuclear waste repository in salt. This document updates a previous unpublished report to the level of the Site Characterization Plan /endash/ Conceptual Design Report, SCP-CDR. The previous unpublished SCC Study identifies the data needs for the Environmental Assessment effort for seven possible salt repository sites

  16. An optical system for controlling ion source parameters

    International Nuclear Information System (INIS)

    Zhang Baifang; Liu Zhenhao; Jiang Yi; Xu Zhengjia

    1999-01-01

    An optical control system used for adjusting the source's parameters of an ion separator is described. There are two slice microcomputers at HV terminal and the ground respectively. These microcomputers communicate each other with the full-duplex mode through two pieces of optical fiber, in which many parameters are time-share transmitted in the form of optical pulse. This system can stabilize the arc current and temperature, adjust and display all parameters and has safe-guard ability. At HV terminal, the optical coupling technique is used for connecting the CPU and the ion source, and at the ground the CPU can communicate with a control microcomputer

  17. Source term modelling parameters for Project-90

    International Nuclear Information System (INIS)

    Shaw, W.; Smith, G.; Worgan, K.; Hodgkinson, D.; Andersson, K.

    1992-04-01

    This document summarises the input parameters for the source term modelling within Project-90. In the first place, the parameters relate to the CALIBRE near-field code which was developed for the Swedish Nuclear Power Inspectorate's (SKI) Project-90 reference repository safety assessment exercise. An attempt has been made to give best estimate values and, where appropriate, a range which is related to variations around base cases. It should be noted that the data sets contain amendments to those considered by KBS-3. In particular, a completely new set of inventory data has been incorporated. The information given here does not constitute a complete set of parameter values for all parts of the CALIBRE code. Rather, it gives the key parameter values which are used in the constituent models within CALIBRE and the associated studies. For example, the inventory data acts as an input to the calculation of the oxidant production rates, which influence the generation of a redox front. The same data is also an initial value data set for the radionuclide migration component of CALIBRE. Similarly, the geometrical parameters of the near-field are common to both sub-models. The principal common parameters are gathered here for ease of reference and avoidance of unnecessary duplication and transcription errors. (au)

  18. Relations between source parameters for large Persian earthquakes

    Directory of Open Access Journals (Sweden)

    Majid Nemati

    2015-11-01

    Full Text Available Empirical relationships for magnitude scales and fault parameters were produced using 436 Iranian intraplate earthquakes of recently regional databases since the continental events represent a large portion of total seismicity of Iran. The relations between different source parameters of the earthquakes were derived using input information which has usefully been provided from the databases after 1900. Suggested equations for magnitude scales relate the body-wave, surface-wave as well as local magnitude scales to scalar moment of the earthquakes. Also, dependence of source parameters as surface and subsurface rupture length and maximum surface displacement on the moment magnitude for some well documented earthquakes was investigated. For meeting this aim, ordinary linear regression procedures were employed for all relations. Our evaluations reveal a fair agreement between obtained relations and equations described in other worldwide and regional works in literature. The M0-mb and M0-MS equations are correlated well to the worldwide relations. Also, both M0-MS and M0-ML relations have a good agreement with regional studies in Taiwan. The equations derived from this study mainly confirm the results of the global investigations about rupture length of historical and instrumental events. However, some relations like MW-MN and MN-ML which are remarkably unlike to available regional works (e.g., American and Canadian were also found.

  19. Further study on source parameters at Quirke Mine, Elliot Lake, Ontario

    International Nuclear Information System (INIS)

    Chen, S.

    1991-01-01

    A further analysis on source parameters for thirty-seven mining-induced seismic events at Quirke Mine, Elliot Lake, Ontario, has been carried out to study the self-similarity assumption in scaling law of seismic spectrum for mining-induced microearthquakes, and to understand the focal mechanism in the mine. Evidence from high P-wave energy in a ratio E p /E s of 5% to 30%, and about 80% of the events with E s /E p L ). For the same total seismic energy, the apparent stress is limited by 80 GN.m and 800 GN.m of seismic moment. The observed stress drop is dependent on the seismic moment, which implies a breakdown in scaling law for events induced by mining. An analysis of peak particle velocity and acceleration presents the evidence for seismic attenuation over the fractured zone above the rock burst area in the mine

  20. Variability of dynamic source parameters inferred from kinematic models of past earthquakes

    KAUST Repository

    Causse, M.

    2013-12-24

    We analyse the scaling and distribution of average dynamic source properties (fracture energy, static, dynamic and apparent stress drops) using 31 kinematic inversion models from 21 crustal earthquakes. Shear-stress histories are computed by solving the elastodynamic equations while imposing the slip velocity of a kinematic source model as a boundary condition on the fault plane. This is achieved using a 3-D finite difference method in which the rupture kinematics are modelled with the staggered-grid-split-node fault representation method of Dalguer & Day. Dynamic parameters are then estimated from the calculated stress-slip curves and averaged over the fault plane. Our results indicate that fracture energy, static, dynamic and apparent stress drops tend to increase with magnitude. The epistemic uncertainty due to uncertainties in kinematic inversions remains small (ϕ ∼ 0.1 in log10 units), showing that kinematic source models provide robust information to analyse the distribution of average dynamic source parameters. The proposed scaling relations may be useful to constrain friction law parameters in spontaneous dynamic rupture calculations for earthquake source studies, and physics-based near-source ground-motion prediction for seismic hazard and risk mitigation.

  1. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  2. Analysis of glottal source parameters in Parkinsonian speech.

    Science.gov (United States)

    Hanratty, Jane; Deegan, Catherine; Walsh, Mary; Kirkpatrick, Barry

    2016-08-01

    Diagnosis and monitoring of Parkinson's disease has a number of challenges as there is no definitive biomarker despite the broad range of symptoms. Research is ongoing to produce objective measures that can either diagnose Parkinson's or act as an objective decision support tool. Recent research on speech based measures have demonstrated promising results. This study aims to investigate the characteristics of the glottal source signal in Parkinsonian speech. An experiment is conducted in which a selection of glottal parameters are tested for their ability to discriminate between healthy and Parkinsonian speech. Results for each glottal parameter are presented for a database of 50 healthy speakers and a database of 16 speakers with Parkinsonian speech symptoms. Receiver operating characteristic (ROC) curves were employed to analyse the results and the area under the ROC curve (AUC) values were used to quantify the performance of each glottal parameter. The results indicate that glottal parameters can be used to discriminate between healthy and Parkinsonian speech, although results varied for each parameter tested. For the task of separating healthy and Parkinsonian speech, 2 out of the 7 glottal parameters tested produced AUC values of over 0.9.

  3. MHODE: a local-homogeneity theory for improved source-parameter estimation of potential fields

    Science.gov (United States)

    Fedi, Maurizio; Florio, Giovanni; Paoletti, Valeria

    2015-08-01

    We describe a multihomogeneity theory for source-parameter estimation of potential fields. Similar to what happens for random source models, where the monofractal scaling-law has been generalized into a multifractal law, we propose to generalize the homogeneity law into a multihomogeneity law. This allows a theoretically correct approach to study real-world potential fields, which are inhomogeneous and so do not show scale invariance, except in the asymptotic regions (very near to or very far from their sources). Since the scaling properties of inhomogeneous fields change with the scale of observation, we show that they may be better studied at a set of scales than at a single scale and that a multihomogeneous model is needed to explain its complex scaling behaviour. In order to perform this task, we first introduce fractional-degree homogeneous fields, to show that: (i) homogeneous potential fields may have fractional or integer degree; (ii) the source-distributions for a fractional-degree are not confined in a bounded region, similarly to some integer-degree models, such as the infinite line mass and (iii) differently from the integer-degree case, the fractional-degree source distributions are no longer uniform density functions. Using this enlarged set of homogeneous fields, real-world anomaly fields are studied at different scales, by a simple search, at any local window W, for the best homogeneous field of either integer or fractional-degree, this yielding a multiscale set of local homogeneity-degrees and depth estimations which we call multihomogeneous model. It is so defined a new technique of source parameter estimation (Multi-HOmogeneity Depth Estimation, MHODE), permitting retrieval of the source parameters of complex sources. We test the method with inhomogeneous fields of finite sources, such as faults or cylinders, and show its effectiveness also in a real-case example. These applications show the usefulness of the new concepts, multihomogeneity and

  4. Laser welding parameters for manufacturing iridium-192 (Ir-192) source

    International Nuclear Information System (INIS)

    Anung Pujiyanto; Moch Subechi; Hotman Lubis; Diandono KY

    2013-01-01

    Number of cervical cancer patients in Indonesia is growing every year. One of cervical cancer treatment was fairly effective use brachytherapy treatment with radioisotope sources of iridium-192. Manufacturing of iridium sources for brachytherapy can be done by incorporating the iridium-192 into stainless steel microcapsules then welding using laser welder which the quality of the welding of iridium source (Ir-192) was determined by the welding parameters such as full power, energy frequency, average power and speed. Based on the result of leakage test using pressure -20 inch Hg and tensile test 2.5 bar showed the welding parameters III and IV did not have leakage and damaged. So that parameters III and IV are recommended to be applied to Ir-192 HDR's source. (author)

  5. Principal parameters of classical multiply charged ion sources

    International Nuclear Information System (INIS)

    Winter, H.; Wolf, B.H.

    1974-01-01

    A review is given of the operational principles of classical multiply charged ion sources (operating sources for intense beams of multiply charged ions using discharge plasmas; MCIS). The fractional rates of creation of multiply charged ions in MCIS plasmas cannot be deduced from the discharge parameters in a simple manner; they depend essentially on three principal parameters, the density and energy distribution of the ionizing electrons, and the confinement time of ions in the ionization space. Simple discharge models were used to find relations between principal parameters, and results of model calculations are compared to actually measured charge state density distributions of extracted ions. Details of processes which determine the energy distribution of ionizing electrons (heating effects), confinement times of ions (instabilities), and some technical aspects of classical MCIS (cathodes, surface processes, conditioning, life time) are discussed

  6. Pseudo-dynamic source modelling with 1-point and 2-point statistics of earthquake source parameters

    KAUST Repository

    Song, S. G.

    2013-12-24

    Ground motion prediction is an essential element in seismic hazard and risk analysis. Empirical ground motion prediction approaches have been widely used in the community, but efficient simulation-based ground motion prediction methods are needed to complement empirical approaches, especially in the regions with limited data constraints. Recently, dynamic rupture modelling has been successfully adopted in physics-based source and ground motion modelling, but it is still computationally demanding and many input parameters are not well constrained by observational data. Pseudo-dynamic source modelling keeps the form of kinematic modelling with its computational efficiency, but also tries to emulate the physics of source process. In this paper, we develop a statistical framework that governs the finite-fault rupture process with 1-point and 2-point statistics of source parameters in order to quantify the variability of finite source models for future scenario events. We test this method by extracting 1-point and 2-point statistics from dynamically derived source models and simulating a number of rupture scenarios, given target 1-point and 2-point statistics. We propose a new rupture model generator for stochastic source modelling with the covariance matrix constructed from target 2-point statistics, that is, auto- and cross-correlations. Our sensitivity analysis of near-source ground motions to 1-point and 2-point statistics of source parameters provides insights into relations between statistical rupture properties and ground motions. We observe that larger standard deviation and stronger correlation produce stronger peak ground motions in general. The proposed new source modelling approach will contribute to understanding the effect of earthquake source on near-source ground motion characteristics in a more quantitative and systematic way.

  7. The Advanced Photon Source list of parameters

    International Nuclear Information System (INIS)

    Bizek, H.M.

    1996-07-01

    The Advanced Photon Source (APS) is a third-generation synchrotron radiation source that stores positrons in a storage ring. The choice of positrons as accelerating particles was motivated by the usual reason: to eliminate the degradation of the beam caused by trapping of positively charged dust particles or ions. The third-generation synchrotron radiation sources are designed to have low beam emittance and many straight sections for insertion devices. The parameter list is comprised of three basic systems: the injection system, the storage ring system, and the experimental facilities system. The components of the injection system are listed according to the causal flow of positrons. Below we briefly list the individual components of the injection system, with the names of people responsible for managing these machines in parentheses: the linac system; electron linac-target-positron linac (Marion White); low energy transport line from linac to the PAR (Michael Borland); positron accumulator ring or PAR (Michael Borland); low energy transport line from PAR to injector synchrotron (Michael Borland); injector synchrotron (Stephen Milton); high energy transport line from injector synchrotron to storage ring (Stephen Milton). The storage ring system, managed by Glenn Decker, uses the Chasman-Green lattice. The APS storage ring, 1104 m in circumference, has 40 periodic sectors. Six are used to house hardware and 34 serve as insertion devices. Another 34 beamlines emit radiation from bending magnets. The experimental facilities system's parameters include parameters for both an undulator and a wiggler

  8. Effects of methods of attenuation correction on source parameter determination

    Science.gov (United States)

    Sonley, Eleanor; Abercrombie, Rachel E.

    We quantify the effects of using different approaches to model individual earthquake spectra. Applying different approaches can introduce significant variability in the calculated source parameters, even when applied to the same data. To compare large and small earthquake source parameters, the results of multiple studies need to be combined to extend the magnitude range, but the variability introduced by the different approaches hampers the outcome. When studies are combined, there is large uncertainty and large scatter and some systematic differences have been neglected. We model individual earthquake spectra from repeating earthquakes (M˜2) at Parkfield, CA, recorded by a borehole network. We focus on the effects of trade-offs between attenuation (Q) and corner frequency in spectral fitting and the effect of the model shape at the corner frequency on radiated energy. The trade-off between attenuation and corner frequency can increase radiated energy by up to 400% and seismic moment by up to 100%.

  9. A parameter study to determine the optimal source neutron energy in boron neutron capture therapy of brain tumours

    Energy Technology Data Exchange (ETDEWEB)

    Nievaart, V A [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Moss, R L [Joint Research Centre of the European Commission, Postbus 2, 1755ZG Petten (Netherlands); Kloosterman, J L [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Hagen, T H J J van der [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands); Dam, H van [Reactor Physics Department, Delft University of Technology, Mekelweg 15, 2629JB Delft (Netherlands)

    2004-09-21

    The values of the parameters used in boron neutron capture therapy (BNCT) to calculate a given dose to human tissue vary with patients due to different physical, biological and/or medical circumstances. Parameters include the tissue dimensions, the {sup 10}B concentration and the relative biological effectiveness (RBE) factors for the different dose components associated with BNCT. Because there is still no worldwide agreement on RBE values, more often than not, average values for these parameters are used. It turns out that the RBE-problem can be circumvented by taking into account all imaginable parameter values. Approaching this quest from another angle: the outcome will also provide the parameters (and values) which influence the optimal source neutron energy. For brain tumours it turns out that the {sup 10}B concentration, the RBE factors for {sup 10}B as well as fast neutrons, together with the dose limit set for healthy tissue, affect the optimal BNCT source neutron energy. By using source neutrons of a few keV together with neutrons of a few eV, it ensures that, under all imaginable circumstances, a maximum of alpha (and lithium) particles can be delivered in the tumour.

  10. Inversion of GPS-measured coseismic displacements for source parameters of Taiwan earthquake

    Science.gov (United States)

    Lin, J. T.; Chang, W. L.; Hung, H. K.; Yu, W. C.

    2016-12-01

    We performed a method of determining earthquake location, focal mechanism, and centroid moment tensor by coseismic surface displacements from daily and high-rate GPS measurements. Unlike commonly used dislocation model where fault geometry is calculated nonlinearly, our method makes a point source approach to evaluate these parameters in a solid and efficient way without a priori fault information and can thus provide constrains to subsequent finite source modeling of fault slip. In this study, we focus on the resolving ability of GPS data for moderate (Mw=6.0 7.0) earthquakes in Taiwan, and four earthquakes were investigated in detail: the March 27 2013 Nantou (Mw=6.0), the June 2 2013 Nantou (Mw=6.3) , the October 31 2013 Ruisui (Mw=6.3), and the March 31 2002 Hualien (ML=6.8) earthquakes. All these events were recorded by the Taiwan continuous GPS network with data sampling rates of 30-second and 1 Hz, where the Mw6.3 Ruisui earthquake was additionally recorded by another local GPS network with a sampling rate of 20 Hz. Our inverted focal mechanisms of all these earthquakes are consistent with the results of GCMT and USGS that evaluates source parameters by dynamic information from seismic waves. We also successfully resolved source parameters of the Mw6.3 Ruisui earthquake within only 10 seconds following the earthquake occurrence, demonstrating the potential of high-rate GPS data on earthquake early warning and real-time determination of earthquake source parameters.

  11. The impacts of source structure on geodetic parameters demonstrated by the radio source 3C371

    Science.gov (United States)

    Xu, Ming H.; Heinkelmann, Robert; Anderson, James M.; Mora-Diaz, Julian; Karbon, Maria; Schuh, Harald; Wang, Guang L.

    2017-07-01

    Closure quantities measured by very-long-baseline interferometry (VLBI) observations are independent of instrumental and propagation instabilities and antenna gain factors, but are sensitive to source structure. A new method is proposed to calculate a structure index based on the median values of closure quantities rather than the brightness distribution of a source. The results are comparable to structure indices based on imaging observations at other epochs and demonstrate the flexibility of deriving structure indices from exactly the same observations as used for geodetic analysis and without imaging analysis. A three-component model for the structure of source 3C371 is developed by model-fitting closure phases. It provides a real case of tracing how the structure effect identified by closure phases in the same observations as the delay observables affects the geodetic analysis, and investigating which geodetic parameters are corrupted to what extent by the structure effect. Using the resulting structure correction based on the three-component model of source 3C371, two solutions, with and without correcting the structure effect, are made. With corrections, the overall rms of this source is reduced by 1 ps, and the impacts of the structure effect introduced by this single source are up to 1.4 mm on station positions and up to 4.4 microarcseconds on Earth orientation parameters. This study is considered as a starting point for handling the source structure effect on geodetic VLBI from geodetic sessions themselves.

  12. A Catalogue of Source Parameters of Moderate and Strong Earthquakes for Turkey and its Surrounding Area (1938-2015)

    Science.gov (United States)

    Kalafat, D.; Toksoz, M. N.

    2015-12-01

    Turkey and Surrounding area, especially North Anatolian Fault Zone (NAFZ), East Anatolian Fault Zone (EAFZ), Western Turkey, cost of the Aegean Sea and Mediterranean Sea regions are seismically very active and undergoing rapid deformation. Earthquakes with M >6.0 do occur every couple of years regularly in this region, Moderate-magnitude seismicity (4.04.0 which were calculated of the fault-source parameters for Turkey and its surrounding area between 1938-2015. The fault source parameters of total over the 1200 earthquakes were calculated. The fault-source parameters of about 56.0 % of the all events were calculated with this study and 44.0 % of the rest were obtained from the other sources. The parameters of the old and incomplete events also were calculated in order to prepare the homogeneous and extended fault- source parameters set in the study. ACKNOWLEDGMENTS This study was supported by the Department of Science Fellowship and Grant programs of TUBITAK (The Scientific and Technological Research Council of Turkey).

  13. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M.; Karam Junior, Dib

    2009-01-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  14. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Erica; Nagatomy, Helio Rissei; Moura, Eduardo S.; Zeituni, Carlos Alberto; Hilario, Katia A. Fonseca; Rostelato, Maria Elisa C.M., E-mail: egauglitz@ipen.b, E-mail: elisaros@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karam Junior, Dib, E-mail: dib.karan@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    This paper presents the survey of parameters for the installation and implementation of a laboratory for radioactive sources production at immobilized resin. These sources are used in nuclear medicine for verification of dose calibrators, as the standard guidelines of the National Commission of Nuclear CNEN-NE-3.05 'Radioprotection and safety requirements for nuclear medicine services.' The radioisotopes used for this purpose are: Co-57, Cs-137 and Ba-133, with activities of 185 MBq, 9.3 MBq and 5.4 MBq, respectively. The parameters for the assembly of the laboratory shall be defined according to guidelines that guide the deployment of radiochemical laboratories and standards of the National Commission of Nuclear Energy. (author)

  15. Determination of Destress Blasting Effectiveness Using Seismic Source Parameters

    Science.gov (United States)

    Wojtecki, Łukasz; Mendecki, Maciej J.; Zuberek, Wacaław M.

    2017-12-01

    Underground mining of coal seams in the Upper Silesian Coal Basin is currently performed under difficult geological and mining conditions. The mining depth, dislocations (faults and folds) and mining remnants are responsible for rockburst hazard in the highest degree. This hazard can be minimized by using active rockburst prevention, where destress blastings play an important role. Destress blastings in coal seams aim to destress the local stress concentrations. These blastings are usually performed from the longwall face to decrease the stress level ahead of the longwall. An accurate estimation of active rockburst prevention effectiveness is important during mining under disadvantageous geological and mining conditions, which affect the risk of rockburst. Seismic source parameters characterize the focus of tremor, which may be useful in estimating the destress blasting effects. Investigated destress blastings were performed in coal seam no. 507 during its longwall mining in one of the coal mines in the Upper Silesian Coal Basin under difficult geological and mining conditions. The seismic source parameters of the provoked tremors were calculated. The presented preliminary investigations enable a rapid estimation of the destress blasting effectiveness using seismic source parameters, but further analysis in other geological and mining conditions with other blasting parameters is required.

  16. High-Resolution Source Parameter and Site Characteristics Using Near-Field Recordings - Decoding the Trade-off Problems Between Site and Source

    Science.gov (United States)

    Chen, X.; Abercrombie, R. E.; Pennington, C.

    2017-12-01

    Recorded seismic waveforms include contributions from earthquake source properties and propagation effects, leading to long-standing trade-off problems between site/path effects and source effects. With near-field recordings, the path effect is relatively small, so the trade-off problem can be simplified to between source and site effects (commonly referred as "kappa value"). This problem is especially significant for small earthquakes where the corner frequencies are within similar ranges of kappa values, so direct spectrum fitting often leads to systematic biases due to corner frequency and magnitude. In response to the significantly increased seismicity rate in Oklahoma, several local networks have been deployed following major earthquakes: the Prague, Pawnee and Fairview earthquakes. Each network provides dense observations within 20 km surrounding the fault zone, recording tens of thousands of aftershocks between M1 to M3. Using near-field recordings in the Prague area, we apply a stacking approach to separate path/site and source effects. The resulting source parameters are consistent with parameters derived from ground motion and spectral ratio methods from other studies; they exhibit spatial coherence within the fault zone for different fault patches. We apply these source parameter constraints in an analysis of kappa values for stations within 20 km of the fault zone. The resulting kappa values show significantly reduced variability compared to those from direct spectral fitting without constraints on the source spectrum; they are not biased by earthquake magnitudes. With these improvements, we plan to apply the stacking analysis to other local arrays to analyze source properties and site characteristics. For selected individual earthquakes, we will also use individual-pair empirical Green's function (EGF) analysis to validate the source parameter estimations.

  17. Analysis of the earthquake data and estimation of source parameters in the Kyungsang basin

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong-Moon; Lee, Jun-Hee [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-04-01

    The purpose of the present study is to determine the response spectrum for the Korean Peninsula and estimate the seismic source parameters and analyze and simulate the ground motion adequately from the seismic characteristics of Korean Peninsula and compare this with the real data. The estimated seismic source parameters such as apparent seismic stress drop is somewhat unstable because the data are insufficient. When the instrumental earthquake data were continuously accumulated in the future, the modification of these parameters may be developed. Although equations presented in this report are derived from the limited data, they can be utilized both in seismology and earthquake engineering. Finally, predictive equations may be given in terms of magnitude and hypocentral distances using these parameters. The estimation of the predictive equation constructed from the simulation is the object of further study. 34 refs., 27 figs., 10 tabs. (Author)

  18. Study on orthorhombic parameters for 3D elastic full waveform inversion

    KAUST Repository

    Oh, Juwon

    2015-08-21

    For a better understanding of the influence of the parameterizations on the multi-parameter full waveform inversion (FWI) for 3D elastic orthorhombic media, we analyze the virtual sources for each cij parameter. Because the virtual sources for cij parameters can be regarded as bases of the virtual sources for other parameterizations, the insights developed here explains many of the scattering phenomena of the different parameters. The resulting radiation patterns provide insights on which parameter set is the best in the multi-parameter FWI for 3D elastic orthorhombic media. In this study, we analyze the virtual source for each cij parameter as a linear combination of several moment tensors. After that, we analyze the strain fields deformed by incident waves as momenta of the virtual source and their influences on sensitivity kernels of each cij parameter.

  19. Study on orthorhombic parameters for 3D elastic full waveform inversion

    KAUST Repository

    Oh, Juwon; Alkhalifah, Tariq Ali

    2015-01-01

    For a better understanding of the influence of the parameterizations on the multi-parameter full waveform inversion (FWI) for 3D elastic orthorhombic media, we analyze the virtual sources for each cij parameter. Because the virtual sources for cij parameters can be regarded as bases of the virtual sources for other parameterizations, the insights developed here explains many of the scattering phenomena of the different parameters. The resulting radiation patterns provide insights on which parameter set is the best in the multi-parameter FWI for 3D elastic orthorhombic media. In this study, we analyze the virtual source for each cij parameter as a linear combination of several moment tensors. After that, we analyze the strain fields deformed by incident waves as momenta of the virtual source and their influences on sensitivity kernels of each cij parameter.

  20. Pseudo-dynamic source modelling with 1-point and 2-point statistics of earthquake source parameters

    KAUST Repository

    Song, S. G.; Dalguer, L. A.; Mai, Paul Martin

    2013-01-01

    statistical framework that governs the finite-fault rupture process with 1-point and 2-point statistics of source parameters in order to quantify the variability of finite source models for future scenario events. We test this method by extracting 1-point

  1. Simultaneous identification of unknown groundwater pollution sources and estimation of aquifer parameters

    Science.gov (United States)

    Datta, Bithin; Chakrabarty, Dibakar; Dhar, Anirban

    2009-09-01

    Pollution source identification is a common problem encountered frequently. In absence of prior information about flow and transport parameters, the performance of source identification models depends on the accuracy in estimation of these parameters. A methodology is developed for simultaneous pollution source identification and parameter estimation in groundwater systems. The groundwater flow and transport simulator is linked to the nonlinear optimization model as an external module. The simulator defines the flow and transport processes, and serves as a binding equality constraint. The Jacobian matrix which determines the search direction in the nonlinear optimization model links the groundwater flow-transport simulator and the optimization method. Performance of the proposed methodology using spatiotemporal hydraulic head values and pollutant concentration measurements is evaluated by solving illustrative problems. Two different decision model formulations are developed. The computational efficiency of these models is compared using two nonlinear optimization algorithms. The proposed methodology addresses some of the computational limitations of using the embedded optimization technique which embeds the discretized flow and transport equations as equality constraints for optimization. Solution results obtained are also found to be better than those obtained using the embedded optimization technique. The performance evaluations reported here demonstrate the potential applicability of the developed methodology for a fairly large aquifer study area with multiple unknown pollution sources.

  2. Research on Matching Method of Power Supply Parameters for Dual Energy Source Electric Vehicles

    Science.gov (United States)

    Jiang, Q.; Luo, M. J.; Zhang, S. K.; Liao, M. W.

    2018-03-01

    A new type of power source is proposed, which is based on the traffic signal matching method of the dual energy source power supply composed of the batteries and the supercapacitors. First, analyzing the power characteristics is required to meet the excellent dynamic characteristics of EV, studying the energy characteristics is required to meet the mileage requirements and researching the physical boundary characteristics is required to meet the physical conditions of the power supply. Secondly, the parameter matching design with the highest energy efficiency is adopted to select the optimal parameter group with the method of matching deviation. Finally, the simulation analysis of the vehicle is carried out in MATLABSimulink, The mileage and energy efficiency of dual energy sources are analyzed in different parameter models, and the rationality of the matching method is verified.

  3. Effect of photon energy spectrum on dosimetric parameters of brachytherapy sources.

    Science.gov (United States)

    Ghorbani, Mahdi; Mehrpouyan, Mohammad; Davenport, David; Ahmadi Moghaddas, Toktam

    2016-06-01

    The aim of this study is to quantify the influence of the photon energy spectrum of brachytherapy sources on task group No. 43 (TG-43) dosimetric parameters. Different photon spectra are used for a specific radionuclide in Monte Carlo simulations of brachytherapy sources. MCNPX code was used to simulate 125I, 103Pd, 169Yb, and 192Ir brachytherapy sources. Air kerma strength per activity, dose rate constant, radial dose function, and two dimensional (2D) anisotropy functions were calculated and isodose curves were plotted for three different photon energy spectra. The references for photon energy spectra were: published papers, Lawrence Berkeley National Laboratory (LBNL), and National Nuclear Data Center (NNDC). The data calculated by these photon energy spectra were compared. Dose rate constant values showed a maximum difference of 24.07% for 103Pd source with different photon energy spectra. Radial dose function values based on different spectra were relatively the same. 2D anisotropy function values showed minor differences in most of distances and angles. There was not any detectable difference between the isodose contours. Dosimetric parameters obtained with different photon spectra were relatively the same, however it is suggested that more accurate and updated photon energy spectra be used in Monte Carlo simulations. This would allow for calculation of reliable dosimetric data for source modeling and calculation in brachytherapy treatment planning systems.

  4. Joint Inversion of Earthquake Source Parameters with local and teleseismic body waves

    Science.gov (United States)

    Chen, W.; Ni, S.; Wang, Z.

    2011-12-01

    In the classical source parameter inversion algorithm of CAP (Cut and Paste method, by Zhao and Helmberger), waveform data at near distances (typically less than 500km) are partitioned into Pnl and surface waves to account for uncertainties in the crustal models and different amplitude weight of body and surface waves. The classical CAP algorithms have proven effective for resolving source parameters (focal mechanisms, depth and moment) for earthquakes well recorded on relatively dense seismic network. However for regions covered with sparse stations, it is challenging to achieve precise source parameters . In this case, a moderate earthquake of ~M6 is usually recorded on only one or two local stations with epicentral distances less than 500 km. Fortunately, an earthquake of ~M6 can be well recorded on global seismic networks. Since the ray paths for teleseismic and local body waves sample different portions of the focal sphere, combination of teleseismic and local body wave data helps constrain source parameters better. Here we present a new CAP mothod (CAPjoint), which emploits both teleseismic body waveforms (P and SH waves) and local waveforms (Pnl, Rayleigh and Love waves) to determine source parameters. For an earthquake in Nevada that is well recorded with dense local network (USArray stations), we compare the results from CAPjoint with those from the traditional CAP method involving only of local waveforms , and explore the efficiency with bootstraping statistics to prove the results derived by CAPjoint are stable and reliable. Even with one local station included in joint inversion, accuracy of source parameters such as moment and strike can be much better improved.

  5. Effects of neutron spectrum and external neutron source on neutron multiplication parameters in accelerator-driven system

    International Nuclear Information System (INIS)

    Shahbunder, Hesham; Pyeon, Cheol Ho; Misawa, Tsuyoshi; Lim, Jae-Yong; Shiroya, Seiji

    2010-01-01

    The neutron multiplication parameters: neutron multiplication M, subcritical multiplication factor k s , external source efficiency φ*, play an important role for numerical assessment and reactor power evaluation of an accelerator-driven system (ADS). Those parameters can be evaluated by using the measured reaction rate distribution in the subcritical system. In this study, the experimental verification of this methodology is performed in various ADS cores; with high-energy (100 MeV) proton-tungsten source in hard and soft neutron spectra cores and 14 MeV D-T neutron source in soft spectrum core. The comparison between measured and calculated multiplication parameters reveals a maximum relative difference in the range of 6.6-13.7% that is attributed to the calculation nuclear libraries uncertainty and accuracy for energies higher than 20 MeV and also dependent on the reaction rate distribution position and count rates. The effects of different core neutron spectra and external neutron sources on the neutron multiplication parameters are discussed.

  6. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Science.gov (United States)

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  7. A probabilistic approach for the estimation of earthquake source parameters from spectral inversion

    Science.gov (United States)

    Supino, M.; Festa, G.; Zollo, A.

    2017-12-01

    The amplitude spectrum of a seismic signal related to an earthquake source carries information about the size of the rupture, moment, stress and energy release. Furthermore, it can be used to characterize the Green's function of the medium crossed by the seismic waves. We describe the earthquake amplitude spectrum assuming a generalized Brune's (1970) source model, and direct P- and S-waves propagating in a layered velocity model, characterized by a frequency-independent Q attenuation factor. The observed displacement spectrum depends indeed on three source parameters, the seismic moment (through the low-frequency spectral level), the corner frequency (that is a proxy of the fault length) and the high-frequency decay parameter. These parameters are strongly correlated each other and with the quality factor Q; a rigorous estimation of the associated uncertainties and parameter resolution is thus needed to obtain reliable estimations.In this work, the uncertainties are characterized adopting a probabilistic approach for the parameter estimation. Assuming an L2-norm based misfit function, we perform a global exploration of the parameter space to find the absolute minimum of the cost function and then we explore the cost-function associated joint a-posteriori probability density function around such a minimum, to extract the correlation matrix of the parameters. The global exploration relies on building a Markov chain in the parameter space and on combining a deterministic minimization with a random exploration of the space (basin-hopping technique). The joint pdf is built from the misfit function using the maximum likelihood principle and assuming a Gaussian-like distribution of the parameters. It is then computed on a grid centered at the global minimum of the cost-function. The numerical integration of the pdf finally provides mean, variance and correlation matrix associated with the set of best-fit parameters describing the model. Synthetic tests are performed to

  8. Model Parameter Variability for Enhanced Anaerobic Bioremediation of DNAPL Source Zones

    Science.gov (United States)

    Mao, X.; Gerhard, J. I.; Barry, D. A.

    2005-12-01

    The objective of the Source Area Bioremediation (SABRE) project, an international collaboration of twelve companies, two government agencies and three research institutions, is to evaluate the performance of enhanced anaerobic bioremediation for the treatment of chlorinated ethene source areas containing dense, non-aqueous phase liquids (DNAPL). This 4-year, 5.7 million dollars research effort focuses on a pilot-scale demonstration of enhanced bioremediation at a trichloroethene (TCE) DNAPL field site in the United Kingdom, and includes a significant program of laboratory and modelling studies. Prior to field implementation, a large-scale, multi-laboratory microcosm study was performed to determine the optimal system properties to support dehalogenation of TCE in site soil and groundwater. This statistically-based suite of experiments measured the influence of key variables (electron donor, nutrient addition, bioaugmentation, TCE concentration and sulphate concentration) in promoting the reductive dechlorination of TCE to ethene. As well, a comprehensive biogeochemical numerical model was developed for simulating the anaerobic dehalogenation of chlorinated ethenes. An appropriate (reduced) version of this model was combined with a parameter estimation method based on fitting of the experimental results. Each of over 150 individual microcosm calibrations involved matching predicted and observed time-varying concentrations of all chlorinated compounds. This study focuses on an analysis of this suite of fitted model parameter values. This includes determining the statistical correlation between parameters typically employed in standard Michaelis-Menten type rate descriptions (e.g., maximum dechlorination rates, half-saturation constants) and the key experimental variables. The analysis provides insight into the degree to which aqueous phase TCE and cis-DCE inhibit dechlorination of less-chlorinated compounds. Overall, this work provides a database of the numerical

  9. Dynamic Source Parameters of the 2008 Wenchuan 8.0, China, Earthquake

    Science.gov (United States)

    Yu, X.; Zhang, W.

    2013-12-01

    On May 12, 2008, a huge earthquake with magnitude Ms 8.0 occurred in the Wenchuan, Sichuan Province of China. This event was the most devastating earthquake in the mainland of China since the Great 1976 M7.8 Tangshan earthquake. It resulted in tremendous losses of life and property. Due to occur in the mountainous area, this great earthquake and the following thousands aftershocks also caused many other geological disasters, such as landslide, mud-rock flow and "quake lakes" which formed by landslide-induced reservoirs. This earthquake occurred along the Longmenshan fault, as the result of motion on a northeast striking reverse fault or thrust fault on the northwestern margin of the Sichuan Basin. The earthquake's epicenter and focal-mechanism are consistent with it having occurred as the result of movement on the Longmenshan fault or a tectonically related fault. The earthquake reflects tectonic stresses resulting from the convergence of crustal material slowly moving from the high Tibetan Plateau, to the west, against strong crust underlying the Sichuan Basin and southeastern China. In this study, the spatial and temporal distribution of the stress on the fault plane of this great earthquake is estimated from the inversion results (Qin & Zhang, 2013) by solving the elastodynamic equations. Then, the dynamic source parameters are determined and the relations between the shear stress and the slip, the shear stress and the slip-rate for all grid positions on the fault are investigated. Finally, the frictional law for the source rupture is inferred from the dynamic source parameters. Based on the obtained dynamic source parameters, we try to rebuild the dynamic rupture process of this event and discuss the characteristics of this great earthquake.

  10. A new method to estimate heat source parameters in gas metal arc welding simulation process

    International Nuclear Information System (INIS)

    Jia, Xiaolei; Xu, Jie; Liu, Zhaoheng; Huang, Shaojie; Fan, Yu; Sun, Zhi

    2014-01-01

    Highlights: •A new method for accurate simulation of heat source parameters was presented. •The partial least-squares regression analysis was recommended in the method. •The welding experiment results verified accuracy of the proposed method. -- Abstract: Heat source parameters were usually recommended by experience in welding simulation process, which induced error in simulation results (e.g. temperature distribution and residual stress). In this paper, a new method was developed to accurately estimate heat source parameters in welding simulation. In order to reduce the simulation complexity, a sensitivity analysis of heat source parameters was carried out. The relationships between heat source parameters and welding pool characteristics (fusion width (W), penetration depth (D) and peak temperature (T p )) were obtained with both the multiple regression analysis (MRA) and the partial least-squares regression analysis (PLSRA). Different regression models were employed in each regression method. Comparisons of both methods were performed. A welding experiment was carried out to verify the method. The results showed that both the MRA and the PLSRA were feasible and accurate for prediction of heat source parameters in welding simulation. However, the PLSRA was recommended for its advantages of requiring less simulation data

  11. Linking source region and ocean wave parameters with the observed primary microseismic noise

    Science.gov (United States)

    Juretzek, C.; Hadziioannou, C.

    2017-12-01

    In previous studies, the contribution of Love waves to the primary microseismic noise field was found to be comparable to those of Rayleigh waves. However, so far only few studies analysed both wave types present in this microseismic noise band, which is known to be generated in shallow water and the theoretical understanding has mainly evolved for Rayleigh waves only. Here, we study the relevance of different source region parameters on the observed primary microseismic noise levels of Love and Rayleigh waves simultaneously. By means of beamforming and correlation of seismic noise amplitudes with ocean wave heights in the period band between 12 and 15 s, we analysed how source areas of both wave types compare with each other around Europe. The generation effectivity in different source regions was compared to ocean wave heights, peak ocean gravity wave propagation direction and bathymetry. Observed Love wave noise amplitudes correlate comparably well with near coastal ocean wave parameters as Rayleigh waves. Some coastal regions serve as especially effective sources for one or the other wave type. These coincide not only with locations of high wave heights but also with complex bathymetry. Further, Rayleigh and Love wave noise amplitudes seem to depend equally on the local ocean wave heights, which is an indication for a coupled variation with swell height during the generation of both wave types. However, the wave-type ratio varies directionally. This observation likely hints towards a spatially varying importance of different source mechanisms or structural influences. Further, the wave-type ratio is modulated depending on peak ocean wave propagation directions which could indicate a variation of different source mechanism strengths but also hints towards an imprint of an effective source radiation pattern. This emphasizes that the inclusion of both wave types may provide more constraints for the understanding of acting generation mechanisms.

  12. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    International Nuclear Information System (INIS)

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  13. Transition to a Source with Modified Physical Parameters by Energy Supply or Using an External Force

    Science.gov (United States)

    Kucherov, A. N.

    2017-11-01

    A study has been made of the possibility for the physical parameters of a source/sink, i.e., for the enthalpy, temperature, total pressure, maximum velocity, and minimum dimension, at a constant radial Mach number to be changed by energy or force action on the gas in a bounded zone. It has been shown that the parameters can be controlled at a subsonic, supersonic, and transonic (sonic in the limit) radial Mach number. In the updated source/sink, all versions of a vortex-source combination can be implemented: into a vacuum, out of a vacuum, into a submerged space, and out of a submerged space, partially or fully.

  14. Fundamental limits of radio interferometers: calibration and source parameter estimation

    OpenAIRE

    Trott, Cathryn M.; Wayth, Randall B.; Tingay, Steven J.

    2012-01-01

    We use information theory to derive fundamental limits on the capacity to calibrate next-generation radio interferometers, and measure parameters of point sources for instrument calibration, point source subtraction, and data deconvolution. We demonstrate the implications of these fundamental limits, with particular reference to estimation of the 21cm Epoch of Reionization power spectrum with next-generation low-frequency instruments (e.g., the Murchison Widefield Array -- MWA, Precision Arra...

  15. Optimization of virtual source parameters in neutron scattering instrumentation

    International Nuclear Information System (INIS)

    Habicht, K; Skoulatos, M

    2012-01-01

    We report on phase-space optimizations for neutron scattering instruments employing horizontal focussing crystal optics. Defining a figure of merit for a generic virtual source configuration we identify a set of optimum instrumental parameters. In order to assess the quality of the instrumental configuration we combine an evolutionary optimization algorithm with the analytical Popovici description using multidimensional Gaussian distributions. The optimum phase-space element which needs to be delivered to the virtual source by preceding neutron optics may be obtained using the same algorithm which is of general interest in instrument design.

  16. Modeling Volcanic Eruption Parameters by Near-Source Internal Gravity Waves.

    Science.gov (United States)

    Ripepe, M; Barfucci, G; De Angelis, S; Delle Donne, D; Lacanna, G; Marchetti, E

    2016-11-10

    Volcanic explosions release large amounts of hot gas and ash into the atmosphere to form plumes rising several kilometers above eruptive vents, which can pose serious risk on human health and aviation also at several thousands of kilometers from the volcanic source. However the most sophisticate atmospheric models and eruptive plume dynamics require input parameters such as duration of the ejection phase and total mass erupted to constrain the quantity of ash dispersed in the atmosphere and to efficiently evaluate the related hazard. The sudden ejection of this large quantity of ash can perturb the equilibrium of the whole atmosphere triggering oscillations well below the frequencies of acoustic waves, down to much longer periods typical of gravity waves. We show that atmospheric gravity oscillations induced by volcanic eruptions and recorded by pressure sensors can be modeled as a compact source representing the rate of erupted volcanic mass. We demonstrate the feasibility of using gravity waves to derive eruption source parameters such as duration of the injection and total erupted mass with direct application in constraining plume and ash dispersal models.

  17. Relating stick-slip friction experiments to earthquake source parameters

    Science.gov (United States)

    McGarr, Arthur F.

    2012-01-01

    Analytical results for parameters, such as static stress drop, for stick-slip friction experiments, with arbitrary input parameters, can be determined by solving an energy-balance equation. These results can then be related to a given earthquake based on its seismic moment and the maximum slip within its rupture zone, assuming that the rupture process entails the same physics as stick-slip friction. This analysis yields overshoots and ratios of apparent stress to static stress drop of about 0.25. The inferred earthquake source parameters static stress drop, apparent stress, slip rate, and radiated energy are robust inasmuch as they are largely independent of the experimental parameters used in their estimation. Instead, these earthquake parameters depend on C, the ratio of maximum slip to the cube root of the seismic moment. C is controlled by the normal stress applied to the rupture plane and the difference between the static and dynamic coefficients of friction. Estimating yield stress and seismic efficiency using the same procedure is only possible when the actual static and dynamic coefficients of friction are known within the earthquake rupture zone.

  18. Relationship between Dietary Fat Intake, Its Major Food Sources and Assisted Reproduction Parameters.

    Science.gov (United States)

    Kazemi, Ashraf; Ramezanzadeh, Fatemeh; Nasr-Esfahani, Mohammad Hosein

    2014-10-01

    High dietary fat consumption may alter oocyte development and embryonic development. This prospective study was conducted to determine the relation between dietary fat consumption level, its food sources and the assisted reproduction parameters. A prospective study was conducted on 240 infertile women. In assisted reproduction treatment cycle, fat consumption and major food sources over the previous three months were identified. The number of retrieved oocytes, metaphase ΙΙ stage oocytes numbers, fertilization rate, embryo quality and clinical pregnancy rate were also determined. The data were analyzed using multiple regression, binary logistic regression, chi-square and t-test. The p-value of less than 0.05 was considered significant. Total fat intake adjusted for age, body mass index, physical activity and etiology of infertility was positively associated with the number of retrieved oocytes and inversely associated with the high embryo quality rate. An inverse association was observed between sausage and turkey ham intake and the number of retrieved oocytes. Also, oil intake level had an inverse association with good cleavage rate. The results revealed that higher levels of fat consumption tend to increase the number of retrieved oocytes and were adversely related to embryonic development. Among food sources of fat, vegetable oil, sausage and turkey ham intake may adversely affect assisted reproduction parameters.

  19. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  20. Dependence of the source performance on plasma parameters at the BATMAN test facility

    Science.gov (United States)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  1. Dependence of the source performance on plasma parameters at the BATMAN test facility

    International Nuclear Information System (INIS)

    Wimmer, C.; Fantz, U.

    2015-01-01

    The investigation of the dependence of the source performance (high j H − , low j e ) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H − , its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H − density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

  2. Spent fuel assembly source term parameters

    International Nuclear Information System (INIS)

    Barrett, P.R.; Foadian, H.; Rashid, Y.R.; Seager, K.D.; Gianoulakis, S.E.

    1993-01-01

    Containment of cask contents by a transport cask is a function of the cask body, one or more closure lids, and various bolting hardware, and seals associated with the cavity closure and other containment penetrations. In addition, characteristics of cask contents that impede the ability of radionuclides to move from an origin to the external environment also provide containment. In essence, multiple release barriers exist in series in transport casks, and the magnitude of the releasable activity in the cask is considerably lower than the total activity of its contents. A source term approach accounts for the magnitude of the releasable activity available in the cask by assessing the degree of barrier resistance to release provided by material characteristics and inherent barriers that impede the release of radioactive contents. Standardized methodologies for defining the spent-fuel transport packages with specified regulations have recently been developed. An essential part of applying the source term methodology involves characterizing the response of the spent fuel under regulatory conditions of transport. Thermal and structural models of the cask and fuel are analyzed and used to predict fuel rod failure probabilities. Input to these analyses and failure evaluations cover a wide range of geometrical and material properties. An important issue in the development of these models is the sensitivity of the radioactive source term generated during transport to individual parameters such as temperature and fluence level. This paper provides a summary of sensitivity analyses concentrating on the structural response and failure predictions of the spent fuel assemblies

  3. Combination of magnetic parameters: an efficient way to discriminate soil-contamination sources (south France)

    International Nuclear Information System (INIS)

    Lecoanet, H.; Leveque, F.; Ambrosi, J.-P.

    2003-01-01

    Biplots combining magnetic parameters allow identification of different pollutant emission sources. - Biplots combining magnetic parameters allow to identification and differentiation different pollutant emission sources. A major problem in soil pollution is the characterization of the relative contributions of different anthropogenic particles sources. This paper demonstrates the efficiency of magnetic techniques to provide identification and differentiation of contaminating emission sources. About 100 soil samples were collected across a mixed agricultural and industrial area (Crau plain/Berre-Fos basin) in southern France. Nine soil profiles were realized. They are aligned along a transect, from the Mediterranean cost to the north. Measurements of initial magnetic susceptibility (χ) and remanent magnetization (ARM, IRM) have been carried out at room temperature. Several ratios of magnetic parameters were calculated and tested. Bivariate analyses allow to characterize different pollution sources and graphic results suggest three dominant contributions originated from road traffic, airport and steel industry. Moreover, magnetic grain-size discrimination between surface-soil samples and bottom-soil samples is obtained. An increase of hard magnetic components from topsoil towards the bottom of the profiles is evidenced

  4. Volcano deformation source parameters estimated from InSAR: Sensitivities to uncertainties in seismic tomography

    Science.gov (United States)

    Masterlark, Timothy; Donovan, Theodore; Feigl, Kurt L.; Haney, Matt; Thurber, Clifford H.; Tung, Sui

    2016-01-01

    The eruption cycle of a volcano is controlled in part by the upward migration of magma. The characteristics of the magma flux produce a deformation signature at the Earth's surface. Inverse analyses use geodetic data to estimate strategic controlling parameters that describe the position and pressurization of a magma chamber at depth. The specific distribution of material properties controls how observed surface deformation translates to source parameter estimates. Seismic tomography models describe the spatial distributions of material properties that are necessary for accurate models of volcano deformation. This study investigates how uncertainties in seismic tomography models propagate into variations in the estimates of volcano deformation source parameters inverted from geodetic data. We conduct finite element model-based nonlinear inverse analyses of interferometric synthetic aperture radar (InSAR) data for Okmok volcano, Alaska, as an example. We then analyze the estimated parameters and their uncertainties to characterize the magma chamber. Analyses are performed separately for models simulating a pressurized chamber embedded in a homogeneous domain as well as for a domain having a heterogeneous distribution of material properties according to seismic tomography. The estimated depth of the source is sensitive to the distribution of material properties. The estimated depths for the homogeneous and heterogeneous domains are 2666 ± 42 and 3527 ± 56 m below mean sea level, respectively (99% confidence). A Monte Carlo analysis indicates that uncertainties of the seismic tomography cannot account for this discrepancy at the 99% confidence level. Accounting for the spatial distribution of elastic properties according to seismic tomography significantly improves the fit of the deformation model predictions and significantly influences estimates for parameters that describe the location of a pressurized magma chamber.

  5. Influence of source parameters on the growth of metal nanoparticles by sputter-gas-aggregation

    Science.gov (United States)

    Khojasteh, Malak; Kresin, Vitaly V.

    2017-11-01

    We describe the production of size-selected manganese nanoclusters using a magnetron sputtering/aggregation source. Since nanoparticle production is sensitive to a range of overlapping operating parameters (in particular, the sputtering discharge power, the inert gas flow rates, and the aggregation length), we focus on a detailed map of the influence of each parameter on the average nanocluster size. In this way, it is possible to identify the main contribution of each parameter to the physical processes taking place within the source. The discharge power and argon flow supply the metal vapor, and argon also plays a crucial role in the formation of condensation nuclei via three-body collisions. However, the argon flow and the discharge power have a relatively weak effect on the average nanocluster size in the exiting beam. Here the defining role is played by the source residence time, governed by the helium supply (which raises the pressure and density of the gas column inside the source, resulting in more efficient transport of nanoparticles to the exit) and by the aggregation path length.

  6. Study of the kinetics parameters for subcritical media driven by source

    International Nuclear Information System (INIS)

    Lee, S.M.; Maiorino, J.R.

    2009-01-01

    This paper presents a theoretical study of reactor kinetics focusing on the methodology of calculation and the experimental measurements of the so-called kinetic parameters. A comparison between the methodology based on the Dulla's formalism and the classical method is made. The objective is to exhibit the dependence of the parameters on sub criticality level and perturbation. Two different slab type systems were considered: thermal one and fast one, both with homogeneous media. One group diffusion model was used for the fast reactor, and for the thermal system, two group diffusion model, considering, in both case only one precursor's family. For reason of simplicity, several additional assumptions were made for calculation of two group method: no up-scattering, fission reaction occurring only in thermal group, etc. The solutions for subcritical systems were obtained using the expansion method, and for critical systems, the methods presented in classical textbooks of reactor physics were applied. The numerical results presented their dependence on sub criticality level and perturbation. (author)

  7. Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

    Science.gov (United States)

    Zaker, Neda; Zehtabian, Mehdi; Sina, Sedigheh; Koontz, Craig; Meigooni, Ali S

    2016-03-08

    Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elements and materials with complex chemical compositions. The accuracies of the final outcomes of these simulations are very sensitive to the accuracies of the cross-sectional libraries. Several investigators have shown that inaccuracies of some of the cross section files have led to errors in 125I and 103Pd parameters. The purpose of this study is to compare the dosimetric parameters of sample brachytherapy sources, calculated with three different versions of the MCNP code - MCNP4C, MCNP5, and MCNPX. In these simulations for each source type, the source and phantom geometries, as well as the number of the photons, were kept identical, thus eliminating the possible uncertainties. The results of these investigations indicate that for low-energy sources such as 125I and 103Pd there are discrepancies in gL(r) values. Discrepancies up to 21.7% and 28% are observed between MCNP4C and other codes at a distance of 6 cm for 103Pd and 10 cm for 125I from the source, respectively. However, for higher energy sources, the discrepancies in gL(r) values are less than 1.1% for 192Ir and less than 1.2% for 137Cs between the three codes.

  8. Optimization of the parameters of power sources excited by β-radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bulyarskiy, S. V., E-mail: bulyar2954@mail.ru; Lakalin, A. V. [Russian Academy of Sciences, Institute of Nanotechnology of Microelectronics (Russian Federation); Abanin, I. E.; Amelichev, V. V. [Technological Center (Russian Federation); Svetuhin, V. V. [Ulyanovsk State University (Russian Federation)

    2017-01-15

    The experimental results and calculations of the efficiency of the energy conversion of Ni-63 β-radiation sources to electricity using silicon p–i–n diodes are presented. All calculations are performed taking into account the energy distribution of β-electrons. An expression for the converter open-circuit voltage is derived taking into account the distribution of high-energy electrons in the space-charge region of the p–i–n diode. Ways of optimizing the converter parameters by improving the technology of diodes and optimizing the emitter active layer and i-region thicknesses of the semiconductor converter are shown. The distribution of the conversion losses to the source and radiation detector and the losses to high-energy electron entry into the semiconductor is calculated. Experimental values of the conversion efficiency of 0.4–0.7% are in good agreement with the calculated parameters.

  9. Impact of fugitive sources and meteorological parameters on vertical distribution of particulate matter over the industrial agglomeration.

    Science.gov (United States)

    Štrbová, Kristína; Raclavská, Helena; Bílek, Jiří

    2017-12-01

    The aim of the study was to characterize vertical distribution of particulate matter, in an area well known by highest air pollution levels in Europe. A balloon filled with helium with measuring instrumentation was used for vertical observation of air pollution over the fugitive sources in Moravian-Silesian metropolitan area during spring and summer. Synchronously, selected meteorological parameters were recorded together with particulate matter for exploration its relationship with particulate matter. Concentrations of particulate matter in the vertical profile were significantly higher in the spring than in the summer. Significant effect of fugitive sources was observed up to the altitude ∼255 m (∼45 m above ground) in both seasons. The presence of inversion layer was observed at the altitude ∼350 m (120-135 m above ground) at locations with major source traffic load. Both particulate matter concentrations and number of particles for the selected particle sizes decreased with increasing height. Strong correlation of particulate matter with meteorological parameters was not observed. The study represents the first attempt to assess the vertical profile over the fugitive emission sources - old environmental burdens in industrial region. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Estimation and applicability of attenuation characteristics for source parameters and scaling relations in the Garhwal Kumaun Himalaya region, India

    Science.gov (United States)

    Singh, Rakesh; Paul, Ajay; Kumar, Arjun; Kumar, Parveen; Sundriyal, Y. P.

    2018-06-01

    Source parameters of the small to moderate earthquakes are significant for understanding the dynamic rupture process, the scaling relations of the earthquakes and for assessment of seismic hazard potential of a region. In this study, the source parameters were determined for 58 small to moderate size earthquakes (3.0 ≤ Mw ≤ 5.0) occurred during 2007-2015 in the Garhwal-Kumaun region. The estimated shear wave quality factor (Qβ(f)) values for each station at different frequencies have been applied to eliminate any bias in the determination of source parameters. The Qβ(f) values have been estimated by using coda wave normalization method in the frequency range 1.5-16 Hz. A frequency-dependent S wave quality factor relation is obtained as Qβ(f) = (152.9 ± 7) f(0.82±0.005) by fitting a power-law frequency dependence model for the estimated values over the whole study region. The spectral (low-frequency spectral level and corner frequency) and source (static stress drop, seismic moment, apparent stress and radiated energy) parameters are obtained assuming ω-2 source model. The displacement spectra are corrected for estimated frequency-dependent attenuation, site effect using spectral decay parameter "Kappa". The frequency resolution limit was resolved by quantifying the bias in corner frequencies, stress drop and radiated energy estimates due to finite-bandwidth effect. The data of the region shows shallow focused earthquakes with low stress drop. The estimation of Zúñiga parameter (ε) suggests the partial stress drop mechanism in the region. The observed low stress drop and apparent stress can be explained by partial stress drop and low effective stress model. Presence of subsurface fluid at seismogenic depth certainly manipulates the dynamics of the region. However, the limited event selection may strongly bias the scaling relation even after taking as much as possible precaution in considering effects of finite bandwidth, attenuation and site corrections

  11. Methods and problems of determination of paleoearthquake magnitudes from fault source parameters

    International Nuclear Information System (INIS)

    Chang, C. J.; Choi, W. H.; Yeon, K. H.; Park, D. H.; Im, C. B.

    2004-01-01

    It has been debated that some of the Quaternary faults which were discovered near the nuclear power plant site whether are capable or not, SE Korea peninsula, thereby, it was necessary to estimate the maximum earthquake potential from the fault source parameters. In this study, we reviewed and analyzed the methods of evaluation of the maximum earthquake potential and also evaluated the maximum credible earthquake from the fault source parameters to the exclusion for the factor of faulting time. We obtained the paleomagnitude range of M 6.82∼7.21 and mean of M 6.98 from a certain fault with 1.5 m displacement of the Quaternary faults have been surveyed along the coast line of the East Sea. And, we also obtained the mean values of M 5.36, M 7.47 and M 6.46 from the other fault which is the fault surface length of 1.5 km, displacement of 4 m and the rate of seismic moment-release, respectively. We consider that a cause of the different paleomagnitudes is due to including the factors of over- and under-estimation in estimating the earthquake potential, and also may not fully identify the detailed geometry and dynamics of the faults

  12. Parameter optimization in biased decoy-state quantum key distribution with both source errors and statistical fluctuations

    Science.gov (United States)

    Zhu, Jian-Rong; Li, Jian; Zhang, Chun-Mei; Wang, Qin

    2017-10-01

    The decoy-state method has been widely used in commercial quantum key distribution (QKD) systems. In view of the practical decoy-state QKD with both source errors and statistical fluctuations, we propose a universal model of full parameter optimization in biased decoy-state QKD with phase-randomized sources. Besides, we adopt this model to carry out simulations of two widely used sources: weak coherent source (WCS) and heralded single-photon source (HSPS). Results show that full parameter optimization can significantly improve not only the secure transmission distance but also the final key generation rate. And when taking source errors and statistical fluctuations into account, the performance of decoy-state QKD using HSPS suffered less than that of decoy-state QKD using WCS.

  13. An open-source job management framework for parameter-space exploration: OACIS

    Science.gov (United States)

    Murase, Y.; Uchitane, T.; Ito, N.

    2017-11-01

    We present an open-source software framework for parameter-space exporation, named OACIS, which is useful to manage vast amount of simulation jobs and results in a systematic way. Recent development of high-performance computers enabled us to explore parameter spaces comprehensively, however, in such cases, manual management of the workflow is practically impossible. OACIS is developed aiming at reducing the cost of these repetitive tasks when conducting simulations by automating job submissions and data management. In this article, an overview of OACIS as well as a getting started guide are presented.

  14. Comparison of TG‐43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes

    Science.gov (United States)

    Zaker, Neda; Sina, Sedigheh; Koontz, Craig; Meigooni1, Ali S.

    2016-01-01

    Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross‐sectional library for the purpose of simulating different elements and materials with complex chemical compositions. The accuracies of the final outcomes of these simulations are very sensitive to the accuracies of the cross‐sectional libraries. Several investigators have shown that inaccuracies of some of the cross section files have led to errors in  125I and  103Pd parameters. The purpose of this study is to compare the dosimetric parameters of sample brachytherapy sources, calculated with three different versions of the MCNP code — MCNP4C, MCNP5, and MCNPX. In these simulations for each source type, the source and phantom geometries, as well as the number of the photons, were kept identical, thus eliminating the possible uncertainties. The results of these investigations indicate that for low‐energy sources such as  125I and  103Pd there are discrepancies in gL(r) values. Discrepancies up to 21.7% and 28% are observed between MCNP4C and other codes at a distance of 6 cm for  103Pd and 10 cm for  125I from the source, respectively. However, for higher energy sources, the discrepancies in gL(r) values are less than 1.1% for  192Ir and less than 1.2% for  137Cs between the three codes. PACS number(s): 87.56.bg PMID:27074460

  15. Bayesian estimation of source parameters and associated Coulomb failure stress changes for the 2005 Fukuoka (Japan) Earthquake

    Science.gov (United States)

    Dutta, Rishabh; Jónsson, Sigurjón; Wang, Teng; Vasyura-Bathke, Hannes

    2018-04-01

    Several researchers have studied the source parameters of the 2005 Fukuoka (northwestern Kyushu Island, Japan) earthquake (Mw 6.6) using teleseismic, strong motion and geodetic data. However, in all previous studies, errors of the estimated fault solutions have been neglected, making it impossible to assess the reliability of the reported solutions. We use Bayesian inference to estimate the location, geometry and slip parameters of the fault and their uncertainties using Interferometric Synthetic Aperture Radar and Global Positioning System data. The offshore location of the earthquake makes the fault parameter estimation challenging, with geodetic data coverage mostly to the southeast of the earthquake. To constrain the fault parameters, we use a priori constraints on the magnitude of the earthquake and the location of the fault with respect to the aftershock distribution and find that the estimated fault slip ranges from 1.5 to 2.5 m with decreasing probability. The marginal distributions of the source parameters show that the location of the western end of the fault is poorly constrained by the data whereas that of the eastern end, located closer to the shore, is better resolved. We propagate the uncertainties of the fault model and calculate the variability of Coulomb failure stress changes for the nearby Kego fault, located directly below Fukuoka city, showing that the main shock increased stress on the fault and brought it closer to failure.

  16. Impact parameter and source selected correlation functions with a 4π multidetector

    International Nuclear Information System (INIS)

    Gourio, D.; Reposeur, T.; Assenard, M.; Germain, M.; Ardouin, D.; Eudes, P.; Lautridou, P.; Laville, J.L.; Lebrun, C.; Metivier, V.

    1997-01-01

    For the first time in the domain of (light charged) particle interferometry in nuclear physics, a complete study of proton an deuteron correlation functions is presented with both impact parameter and emission source selections. The correlations were determined for the system 129 Xe + nat Sn at 45 and 50 AMeV using the 4π multidetector INDRA at GANIL as an event selector as well as a particle correlator. Very short emission times are found for all the selections indicating possible contributions from a fast and preequilibrium process. (author)

  17. Optimization of the plasma parameters for the high current and uniform large-scale pulse arc ion source of the VEST-NBI system

    International Nuclear Information System (INIS)

    Jung, Bongki; Park, Min; Heo, Sung Ryul; Kim, Tae-Seong; Jeong, Seung Ho; Chang, Doo-Hee; Lee, Kwang Won; In, Sang-Ryul

    2016-01-01

    Highlights: • High power magnetic bucket-type arc plasma source for the VEST NBI system is developed with modifications based on the prototype plasma source for KSTAR. • Plasma parameters in pulse duration are measured to characterize the plasma source. • High plasma density and good uniformity is achieved at the low operating pressure below 1 Pa. • Required ion beam current density is confirmed by analysis of plasma parameters and results of a particle balance model. - Abstract: A large-scale hydrogen arc plasma source was developed at the Korea Atomic Energy Research Institute for a high power pulsed NBI system of VEST which is a compact spherical tokamak at Seoul national university. One of the research target of VEST is to study innovative tokamak operating scenarios. For this purpose, high current density and uniform large-scale pulse plasma source is required to satisfy the target ion beam power efficiently. Therefore, optimizing the plasma parameters of the ion source such as the electron density, temperature, and plasma uniformity is conducted by changing the operating conditions of the plasma source. Furthermore, ion species of the hydrogen plasma source are analyzed using a particle balance model to increase the monatomic fraction which is another essential parameter for increasing the ion beam current density. Conclusively, efficient operating conditions are presented from the results of the optimized plasma parameters and the extractable ion beam current is calculated.

  18. Modal parameter identification based on combining transmissibility functions and blind source separation techniques

    Science.gov (United States)

    Araújo, Iván Gómez; Sánchez, Jesús Antonio García; Andersen, Palle

    2018-05-01

    Transmissibility-based operational modal analysis is a recent and alternative approach used to identify the modal parameters of structures under operational conditions. This approach is advantageous compared with traditional operational modal analysis because it does not make any assumptions about the excitation spectrum (i.e., white noise with a flat spectrum). However, common methodologies do not include a procedure to extract closely spaced modes with low signal-to-noise ratios. This issue is relevant when considering that engineering structures generally have closely spaced modes and that their measured responses present high levels of noise. Therefore, to overcome these problems, a new combined method for modal parameter identification is proposed in this work. The proposed method combines blind source separation (BSS) techniques and transmissibility-based methods. Here, BSS techniques were used to recover source signals, and transmissibility-based methods were applied to estimate modal information from the recovered source signals. To achieve this combination, a new method to define a transmissibility function was proposed. The suggested transmissibility function is based on the relationship between the power spectral density (PSD) of mixed signals and the PSD of signals from a single source. The numerical responses of a truss structure with high levels of added noise and very closely spaced modes were processed using the proposed combined method to evaluate its ability to identify modal parameters in these conditions. Colored and white noise excitations were used for the numerical example. The proposed combined method was also used to evaluate the modal parameters of an experimental test on a structure containing closely spaced modes. The results showed that the proposed combined method is capable of identifying very closely spaced modes in the presence of noise and, thus, may be potentially applied to improve the identification of damping ratios.

  19. Parameter identification for continuous point emission source based on Tikhonov regularization method coupled with particle swarm optimization algorithm.

    Science.gov (United States)

    Ma, Denglong; Tan, Wei; Zhang, Zaoxiao; Hu, Jun

    2017-03-05

    In order to identify the parameters of hazardous gas emission source in atmosphere with less previous information and reliable probability estimation, a hybrid algorithm coupling Tikhonov regularization with particle swarm optimization (PSO) was proposed. When the source location is known, the source strength can be estimated successfully by common Tikhonov regularization method, but it is invalid when the information about both source strength and location is absent. Therefore, a hybrid method combining linear Tikhonov regularization and PSO algorithm was designed. With this method, the nonlinear inverse dispersion model was transformed to a linear form under some assumptions, and the source parameters including source strength and location were identified simultaneously by linear Tikhonov-PSO regularization method. The regularization parameters were selected by L-curve method. The estimation results with different regularization matrixes showed that the confidence interval with high-order regularization matrix is narrower than that with zero-order regularization matrix. But the estimation results of different source parameters are close to each other with different regularization matrixes. A nonlinear Tikhonov-PSO hybrid regularization was also designed with primary nonlinear dispersion model to estimate the source parameters. The comparison results of simulation and experiment case showed that the linear Tikhonov-PSO method with transformed linear inverse model has higher computation efficiency than nonlinear Tikhonov-PSO method. The confidence intervals from linear Tikhonov-PSO are more reasonable than that from nonlinear method. The estimation results from linear Tikhonov-PSO method are similar to that from single PSO algorithm, and a reasonable confidence interval with some probability levels can be additionally given by Tikhonov-PSO method. Therefore, the presented linear Tikhonov-PSO regularization method is a good potential method for hazardous emission

  20. Study of the applicability of Markov chain Monte Carlo methods to the statistical separation of electron sources via the impact parameter for ALICE

    Energy Technology Data Exchange (ETDEWEB)

    Wittner, Manuel [Physikalisches Institut, Universitaet Heidelberg, Heidelberg (Germany); Collaboration: ALICE-Collaboration

    2015-07-01

    One particularly interesting measurement detected by the ALICE set-up at the LHC are electrons from charm and beauty hadron decays. Heavy quarks originate from initial hard scattering processes and thus experience the whole history of a heavy ion collision. Therefore, they are valuable probes to study the mechanisms of energy loss and hadronization in the hot and dense state of matter, that is expected to be formed in a heavy-ion collision at LHC. One important task is the distinction of the different electron sources, for which a method was developed. Hereby, the impact parameter distribution of the measurement data is compared with impact parameter distributions for the individual sources, which are created through Monte Carlo simulations. Afterwards, a maximum likelihood fit is applied. However, creating a posterior distribution of the likelihood according to Bayes' theorem and sampling it with Markov Chain Monte Carlo algorithms provides several advantages, e.g. a mathematically correct estimation of the uncertainties or the usage of prior knowledge. Hence for the first time in this particular problem, a Markov Chain Monte Carlo algorithm, namely the Metropolis algorithm, was implemented and investigated for its applicability in heavy flavor physics. First studies indicate its great usefulness in this field of physics.

  1. Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipment

    International Nuclear Information System (INIS)

    Gauglitz, Erica

    2010-01-01

    This paper presents a survey of parameters for the proper and safe flooring, doors, windows, fume hoods and others, in a radiochemical laboratory. The layout of each item follows guidelines and national standards of the National Commission of Nuclear Energy (CNEN) and the International Atomic Energy Agency (IAEA), aiming to ensure the radiological protection of workers and environment. The adequate items arrangement in the radiochemical laboratory ensures quality and safety in the production of 57 Co 137 Cs and 133 Ba radioactive sealed sources, with activities 185, 9.3 and 5.4 MBq, respectively. These sources are used to verify meter activity equipment and should be available throughout the Nuclear Medicine Center, following the recommendations of CNEN-NN-3.05 standard R equirements for Radiation Protection and Safety Services for Nuclear Medicine , to verify the activity of radiopharmaceuticals that are administered in patients, for diagnosis and therapy. Verification of measuring activity equipment will be used to perform accuracy, reproducibility and linearity tests, which should show results within the limits specified in the standard CNEN-NN-3.05. (author)

  2. The influence of source term release parameters on health effects

    International Nuclear Information System (INIS)

    Jeong, Jong Tae; Ha, Jae Joo

    1998-08-01

    In this study, the influence of source term release parameters on the health effects was examined. This is very useful in identifying the relative importance of release parameters and can be an important factor in developing a strategy for reducing offsite risks. The release parameters investigated in this study are release height, heat content, fuel burnup, release time, release duration, and warning time. The health effects affected by the change of release parameters are early fatalities, cancer fatalities, early injuries, cancer injuries, early fatality risk, population weighted early fatality risk, population weighted cancer fatality risk, effective whole body population dose, population exceeding an early acute red bone marrow dose of 1.5 Sv, and distance at which early fatalities are expected to occur. As release height increases, the values of early health effects such as early fatalities and injuries decrease. However, the release height dose not have significant influences on late health effects. The values of both early and late health effects decrease as heat content increases. The increase fuel burnup, i.e., the increase of core inventories increases the late health effects, however, has small influence on the early health effects. But, the number of early injuries increases as the fuel burnup increases. The effects of release time increase shows very similar influence on both the early and late health effects. As the release time increases to 2 hours, the values of health effects increase and then decrease rapidly. As release duration increases, the values of late health effects increase slightly, however, the values of early health effects decrease. As warning time increases to 2 hours, the values of late health effects decrease and then shows no variation. The number of early injuries decreases rapidly as the warning time increases to 2 hours. However, the number of early fatalities and the early fatality risk increase as the warning time increases

  3. Bayesian Estimation of Source Parameters and Associated Coulomb Failure Stress Changes for the 2005 Fukuoka (Japan) Earthquake

    KAUST Repository

    Dutta, Rishabh

    2017-12-20

    Several researchers have studied the source parameters of the 2005 Fukuoka (northwestern Kyushu Island, Japan) earthquake (MW 6.6) using teleseismic, strong motion and geodetic data. However, in all previous studies, errors of the estimated fault solutions have been neglected, making it impossible to assess the reliability of the reported solutions. We use Bayesian inference to estimate the location, geometry and slip parameters of the fault and their uncertainties using Interferometric Synthetic Aperture Radar (InSAR) and Global Positioning System (GPS) data. The offshore location of the earthquake makes the fault parameter estimation challenging, with geodetic data coverage mostly to the southeast of the earthquake. To constrain the fault parameters, we use a priori constraints on the magnitude of the earthquake and the location of the fault with respect to the aftershock distribution and find that the estimated fault slip ranges from 1.5 m to 2.5 m with decreasing probability. The marginal distributions of the source parameters show that the location of the western end of the fault is poorly constrained by the data whereas that of the eastern end, located closer to the shore, is better resolved. We propagate the uncertainties of the fault model and calculate the variability of Coulomb failure stress changes for the nearby Kego fault, located directly below Fukuoka city, showing that the mainshock increased stress on the fault and brought it closer to failure.

  4. Source Parameters for Moderate Earthquakes in the Zagros Mountains with Implications for the Depth Extent of Seismicity

    Energy Technology Data Exchange (ETDEWEB)

    Adams, A; Brazier, R; Nyblade, A; Rodgers, A; Al-Amri, A

    2009-02-23

    Six earthquakes within the Zagros Mountains with magnitudes between 4.9 and 5.7 have been studied to determine their source parameters. These events were selected for study because they were reported in open catalogs to have lower crustal or upper mantle source depths and because they occurred within an area of the Zagros Mountains where crustal velocity structure has been constrained by previous studies. Moment tensor inversion of regional broadband waveforms have been combined with forward modeling of depth phases on short period teleseismic waveforms to constrain source depths and moment tensors. Our results show that all six events nucleated within the upper crust (<11 km depth) and have thrust mechanisms. This finding supports other studies that call into question the existence of lower crustal or mantle events beneath the Zagros Mountains.

  5. Preliminary Result of Earthquake Source Parameters the Mw 3.4 at 23:22:47 IWST, August 21, 2004, Centre Java, Indonesia Based on MERAMEX Project

    Science.gov (United States)

    Laksono, Y. A.; Brotopuspito, K. S.; Suryanto, W.; Widodo; Wardah, R. A.; Rudianto, I.

    2018-03-01

    In order to study the structure subsurface at Merapi Lawu anomaly (MLA) using forward modelling or full waveform inversion, it needs a good earthquake source parameters. The best result source parameter comes from seismogram with high signal to noise ratio (SNR). Beside that the source must be near the MLA location and the stations that used as parameters must be outside from MLA in order to avoid anomaly. At first the seismograms are processed by software SEISAN v10 using a few stations from MERAMEX project. After we found the hypocentre that match the criterion we fine-tuned the source parameters using more stations. Based on seismogram from 21 stations, it is obtained the source parameters as follows: the event is at August, 21 2004, on 23:22:47 Indonesia western standard time (IWST), epicentre coordinate -7.80°S, 101.34°E, hypocentre 47.3 km, dominant frequency f0 = 3.0 Hz, the earthquake magnitude Mw = 3.4.

  6. Plasma jet source parameter optimisation and experiments on injection into Globus-M spherical tokamak

    International Nuclear Information System (INIS)

    Gusev, V.K.; Petrov, Yu.V.; Sakharov, N.V.; Semenov, A.A.; Voronin, A.V.

    2005-01-01

    Results of theoretical and experimental research on the plasma sources and injection of plasma and gas jet produced by the modified source into tokamak Globus-M are presented. An experimental test stand was developed for investigation of intense plasma jet generation. Optimisation of pulsed coaxial accelerator parameters by means of analytical calculations is performed with the aim of achieving the highest flow velocity at limited coaxial electrode length and discharge current. The optimal parameters of power supply to generate a plasma jet with minimal impurity contamination and maximum flow velocity were determined. A comparison of experimental and calculation results is made. Plasma jet parameters are measured, such as: impurity species content, pressure distribution across the jet, flow velocity, plasma density, etc. Experiments on the interaction of a higher kinetic energy plasma jet with the magnetic field and plasma of the Globus-M tokamak were performed. Experimental results on plasma and gas jet injection into different Globus-M discharge phases are presented and discussed. Results are presented on the investigation of plasma jet injection as the source for discharge breakdown, plasma current startup and initial density rise. (author)

  7. Revision of the dosimetric parameters of the CSM11 LDR Cs-137 source.

    Science.gov (United States)

    Otal, Antonio; Martínez-Fernández, Juan Manuel; Granero, Domingo

    2011-03-01

    The clinical use of brachytherapy sources requires the existence of dosimetric data with enough of quality for the proper application of treatments in clinical practice. It has been found that the published data for the low dose rate CSM11 Cs-137 source lacks of smoothness in some regions because the data are too noisy. The purpose of this study was to calculate the dosimetric data for this source in order to provide quality dosimetric improvement of the existing dosimetric data of Ballester et al . [1]. In order to obtain the dose rate distributions Monte Carlo simulations were done using the GEANT4 code. A spherical phantom 40 cm in radius with the Cs-137 source located at the centre of the phantom was used. The results from Monte Carlo simulations were applied to derive AAPM Task Group 43 dosimetric parameters: anisotropy function, radial dose function, air kerma strength and dose rate constant. The dose rate constant obtained was 1.094 ± 0.002 cGy h -1 U -1 . The new calculated data agrees within experimental uncertainties with the existing data of Ballester et al . but without the statistical noise of that study. The obtained data presently fulfills all the requirements of the TG-43U1 update and thus it can be used in clinical practice.

  8. Source inversion in the full-wave tomography; Full wave tomography ni okeru source inversion

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, T [DIA Consultants Co. Ltd., Tokyo (Japan)

    1997-10-22

    In order to consider effects of characteristics of a vibration source in the full-wave tomography (FWT), a study has been performed on a method to invert vibration source parameters together with V(p)/V(s) distribution. The study has expanded an analysis method which uses as the basic the gradient method invented by Tarantola and the partial space method invented by Sambridge, and conducted numerical experiments. The experiment No. 1 has performed inversion of only the vibration source parameters, and the experiment No. 2 has executed simultaneous inversion of the V(p)/V(s) distribution and the vibration source parameters. The result of the discussions revealed that and effective analytical procedure would be as follows: in order to predict maximum stress, the average vibration source parameters and the property parameters are first inverted simultaneously; in order to estimate each vibration source parameter at a high accuracy, the property parameters are fixed, and each vibration source parameter is inverted individually; and the derived vibration source parameters are fixed, and the property parameters are again inverted from the initial values. 5 figs., 2 tabs.

  9. Modulating Function-Based Method for Parameter and Source Estimation of Partial Differential Equations

    KAUST Repository

    Asiri, Sharefa M.

    2017-01-01

    Partial Differential Equations (PDEs) are commonly used to model complex systems that arise for example in biology, engineering, chemistry, and elsewhere. The parameters (or coefficients) and the source of PDE models are often unknown

  10. Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

    International Nuclear Information System (INIS)

    Xie, Y.H.; Hu, C.D.; Liu, S.; Shong, S.H.; Jiang, C.C.; Liu, Z.M.

    2010-01-01

    Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

  11. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    International Nuclear Information System (INIS)

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  12. Sensitivity of numerical dispersion modeling to explosive source parameters

    International Nuclear Information System (INIS)

    Baskett, R.L.; Cederwall, R.T.

    1991-01-01

    The calculation of downwind concentrations from non-traditional sources, such as explosions, provides unique challenges to dispersion models. The US Department of Energy has assigned the Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory (LLNL) the task of estimating the impact of accidental radiological releases to the atmosphere anywhere in the world. Our experience includes responses to over 25 incidents in the past 16 years, and about 150 exercises a year. Examples of responses to explosive accidents include the 1980 Titan 2 missile fuel explosion near Damascus, Arkansas and the hydrogen gas explosion in the 1986 Chernobyl nuclear power plant accident. Based on judgment and experience, we frequently estimate the source geometry and the amount of toxic material aerosolized as well as its particle size distribution. To expedite our real-time response, we developed some automated algorithms and default assumptions about several potential sources. It is useful to know how well these algorithms perform against real-world measurements and how sensitive our dispersion model is to the potential range of input values. In this paper we present the algorithms we use to simulate explosive events, compare these methods with limited field data measurements, and analyze their sensitivity to input parameters. 14 refs., 7 figs., 2 tabs

  13. Quantifying undesired parallel components in Thévenin-equivalent acoustic source parameters

    DEFF Research Database (Denmark)

    Nørgaard, Kren Rahbek; Neely, Stephen T.; Rasetshwane, Daniel M.

    2018-01-01

    in the source parameters. Such parallel components can result from, e.g., a leak in the ear tip or improperly accounting for evanescent modes, and introduce errors into subsequent measurements of impedance and reflectance. This paper proposes a set of additional error metrics that are capable of detecting...

  14. Simultaneous reconstruction of material and transient source parameters using the invariant imbedding method

    International Nuclear Information System (INIS)

    Corones, J.; Sun, Z.

    1993-01-01

    This paper extends the time domain wave splitting and invariant imbedding method to an inhomogeneous wave equation with a source term: u xx -u tt +A(x)u x =2D(x)i'(t). The direct scattering and inverse source problems of this equation are studied. Operators J ± that map the source function into the scattered waves at the edges of the slab are defined. A system of coupled nonlinear integrodifferential equations for these scattering operator kernels is obtained. The direct scattering problem is to obtain the scattering operator kernels J ± and R + when parameters A and D are given. The inverse problem is to simultaneously reconstruct A(x) and D(x) from the scattering operator kernels R + (0,t), 0≤t≤2 and J - (0,t), 0≤t≤1. Both numerical inversion algorithms and the small time approximate reconstruction method are presented. A Green's function technique is used to derive Green's operator kernel equations for the calculation of the internal field. It provides an alternative effective and fast way to compute the scattering kernels J ± . For constant A and D the Green's operator kernels and source scattering kernels are expressed in closed form. Several numerical examples are given

  15. Earthquake Source Parameters Inferred from T-Wave Observations

    Science.gov (United States)

    Perrot, J.; Dziak, R.; Lau, T. A.; Matsumoto, H.; Goslin, J.

    2004-12-01

    The seismicity of the North Atlantic Ocean has been recorded by two networks of autonomous hydrophones moored within the SOFAR channel on the flanks of the Mid-Atlantic Ridge (MAR). In February 1999, a consortium of U.S. investigators (NSF and NOAA) deployed a 6-element hydrophone array for long-term monitoring of MAR seismicity between 15o-35oN south of the Azores. In May 2002, an international collaboration of French, Portuguese, and U.S. researchers deployed a 6-element hydrophone array north of the Azores Plateau from 40o-50oN. The northern network (referred to as SIRENA) was recovered in September 2003. The low attenuation properties of the SOFAR channel for earthquake T-wave propagation results in a detection threshold reduction from a magnitude completeness level (Mc) of ˜ 4.7 for MAR events recorded by the land-based seismic networks to Mc=3.0 using hydrophone arrays. Detailed focal depth and mechanism information, however, remain elusive due to the complexities of seismo-acoustic propagation paths. Nonetheless, recent analyses (Dziak, 2001; Park and Odom, 2001) indicate fault parameter information is contained within the T-wave signal packet. We investigate this relationship further by comparing an earthquake's T-wave duration and acoustic energy to seismic magnitude (NEIC) and radiation pattern (for events M>5) from the Harvard moment-tensor catalog. First results show earthquake energy is well represented by the acoustic energy of the T-waves, however T-wave codas are significantly influenced by acoustic propagation effects and do not allow a direct determination of the seismic magnitude of the earthquakes. Second, there appears to be a correlation between T-wave acoustic energy, azimuth from earthquake source to the hydrophone, and the radiation pattern of the earthquake's SH waves. These preliminary results indicate there is a relationship between the T-wave observations and earthquake source parameters, allowing for additional insights into T

  16. Optimization of light source parameters in the photodynamic therapy of heterogeneous prostate

    International Nuclear Information System (INIS)

    Li Jun; Altschuler, Martin D; Hahn, Stephen M; Zhu, Timothy C

    2008-01-01

    results from heterogeneous optical data with those obtained from average homogeneous optical properties. The optimized treatment plans are also compared with the reference clinical plan, defined as the plan with sources of equal strength, distributed regularly in space, which delivers a mean value of prescribed fluence at detector locations within the treatment region. The study suggests that comprehensive optimization of source parameters (i.e. strengths, lengths and locations) is feasible, thus allowing acceptable dose coverage in a heterogeneous prostate PDT within the time constraints of the PDT procedure

  17. A Parameter Identification Method for Helicopter Noise Source Identification and Physics-Based Semi-Empirical Modeling

    Science.gov (United States)

    Greenwood, Eric, II; Schmitz, Fredric H.

    2010-01-01

    A new physics-based parameter identification method for rotor harmonic noise sources is developed using an acoustic inverse simulation technique. This new method allows for the identification of individual rotor harmonic noise sources and allows them to be characterized in terms of their individual non-dimensional governing parameters. This new method is applied to both wind tunnel measurements and ground noise measurements of two-bladed rotors. The method is shown to match the parametric trends of main rotor Blade-Vortex Interaction (BVI) noise, allowing accurate estimates of BVI noise to be made for operating conditions based on a small number of measurements taken at different operating conditions.

  18. Rated parameters of the JINR synchrotron radiation source for the electron energy 0.7 GeV

    International Nuclear Information System (INIS)

    Aksenov, V.L.; Belushkin, A.V.; Meshkov, I.N.; Syresin, E.M.; Tyutyunnikov, S.I.

    1998-01-01

    This paper gives the first estimates of the rated parameters of the JINR compact synchrotron radiation (SR) source for the electron energy 0.7 GeV. The realization of the JINR SR source which incorporates superconducting wigglers and an undulator will make it possible to construct few channels for hard X-rays with the energy up to 10 keV. The project for the construction of the SR source is motivated by the purposes of X-ray lithography and micromechanics, the so-called LIGA process. The energy spectrum of SR from the bending magnets in the source covers the energy range from infra-red to ultra-violet. This SR can be used at several stations for investigations in the field of condensed matter physics in the infra-red region, such as studies of impurities in semiconductors, measurements of the superconducting gap, radiometry in the vacuum ultra-violet region

  19. Source and path parameters determination based on data from the digital accelerometer and CALIXTO networks to assess the seismic hazard

    International Nuclear Information System (INIS)

    Radulian, M.; Anghel, M.; Ardeleanu, L.; Bazacliu, O.; Grecu, B.; Popa, M.; Popescu, E.; Rizescu, M.

    2002-01-01

    stress drop are estimated using the best approximation of the spectral ratio theoretical function. From acceleration spectra we obtain in addition the parameters associated with the high-frequency source behavior (maximum frequency and high-frequency spectral decay). An alternative inversion method uses the displacement of the body waves (P and S phases), corrected for instrument response. Seismic moment, source radius, stress drop, seismic energy, apparent stress, final dislocation are obtained for 16 Vrancea earthquakes occurred between 2000 and 2001. The inversion scheme allows also the determination of the seismic moment tensor. The inversion algorithm proposed to retrieve the seismic moment tensor using high-frequency waveforms of local events is applied for a set of small-magnitude crustal events. The structural model is one-dimensional and the limitation to the one-dimensional case can introduce serious distortions of the source parameters taking into consideration the complex tectonic framework of the studied area (Eastern Carpathians foredeep region). Several experimental tests are performed to analyze the sensitivity of the seismic moment tensor solution to the inadequacies of the structure model and earthquake localization. Distortions caused by hypocenter location errors are relatively small and do not change the general character of the principal axes. Other important characteristics of the seismic source, such as directivity and complexity, are considered as well. As shown earlier, the relative deconvolution methods, such as spectral ratio method and empirical Green's function method, are very useful to detect directivity and complexity effects. These effects are revealed when the degree of asymmetry of the waveforms, the azimuthal distribution of the observation sites and the quality of seismograms are sufficiently high. The directivity allows the identification of the real rupture plane among the two nodal planes. The resulted source parameters are

  20. A systematic approach to evaluate parameter consistency in the inlet stream of source separated biowaste composting facilities: A case study in Colombia.

    Science.gov (United States)

    Oviedo-Ocaña, E R; Torres-Lozada, P; Marmolejo-Rebellon, L F; Torres-López, W A; Dominguez, I; Komilis, D; Sánchez, A

    2017-04-01

    Biowaste is commonly the largest fraction of municipal solid waste (MSW) in developing countries. Although composting is an effective method to treat source separated biowaste (SSB), there are certain limitations in terms of operation, partly due to insufficient control to the variability of SSB quality, which affects process kinetics and product quality. This study assesses the variability of the SSB physicochemical quality in a composting facility located in a small town of Colombia, in which SSB collection was performed twice a week. Likewise, the influence of the SSB physicochemical variability on the variability of compost parameters was assessed. Parametric and non-parametric tests (i.e. Student's t-test and the Mann-Whitney test) showed no significant differences in the quality parameters of SSB among collection days, and therefore, it was unnecessary to establish specific operation and maintenance regulations for each collection day. Significant variability was found in eight of the twelve quality parameters analyzed in the inlet stream, with corresponding coefficients of variation (CV) higher than 23%. The CVs for the eight parameters analyzed in the final compost (i.e. pH, moisture, total organic carbon, total nitrogen, C/N ratio, total phosphorus, total potassium and ash) ranged from 9.6% to 49.4%, with significant variations in five of those parameters (CV>20%). The above indicate that variability in the inlet stream can affect the variability of the end-product. Results suggest the need to consider variability of the inlet stream in the performance of composting facilities to achieve a compost of consistent quality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Delineation of seismic source zones based on seismicity parameters ...

    Indian Academy of Sciences (India)

    these source zones were evaluated and were used in the hazard evaluation. ... seismic sources, linear and areal, were considered in the present study to model the seismic sources in the ..... taken as an authentic reference manual for iden-.

  2. Modulating Function-Based Method for Parameter and Source Estimation of Partial Differential Equations

    KAUST Repository

    Asiri, Sharefa M.

    2017-10-08

    Partial Differential Equations (PDEs) are commonly used to model complex systems that arise for example in biology, engineering, chemistry, and elsewhere. The parameters (or coefficients) and the source of PDE models are often unknown and are estimated from available measurements. Despite its importance, solving the estimation problem is mathematically and numerically challenging and especially when the measurements are corrupted by noise, which is often the case. Various methods have been proposed to solve estimation problems in PDEs which can be classified into optimization methods and recursive methods. The optimization methods are usually heavy computationally, especially when the number of unknowns is large. In addition, they are sensitive to the initial guess and stop condition, and they suffer from the lack of robustness to noise. Recursive methods, such as observer-based approaches, are limited by their dependence on some structural properties such as observability and identifiability which might be lost when approximating the PDE numerically. Moreover, most of these methods provide asymptotic estimates which might not be useful for control applications for example. An alternative non-asymptotic approach with less computational burden has been proposed in engineering fields based on the so-called modulating functions. In this dissertation, we propose to mathematically and numerically analyze the modulating functions based approaches. We also propose to extend these approaches to different situations. The contributions of this thesis are as follows. (i) Provide a mathematical analysis of the modulating function-based method (MFBM) which includes: its well-posedness, statistical properties, and estimation errors. (ii) Provide a numerical analysis of the MFBM through some estimation problems, and study the sensitivity of the method to the modulating functions\\' parameters. (iii) Propose an effective algorithm for selecting the method\\'s design parameters

  3. Comparative studies of energy sources in gynecologic laparoscopy.

    Science.gov (United States)

    Law, Kenneth S K; Lyons, Stephen D

    2013-01-01

    Energy sources incorporating "vessel sealing" capabilities are being increasingly used in gynecologic laparoscopic surgery although conventional monopolar and bipolar electrosurgery remain popular. The preference for one device over another is based on a combination of factors, including the surgeon's subjective experience, availability, and cost. Although comparative clinical studies and meta-analyses of laparoscopic energy sources have reported small but statistically significant differences in volumes of blood loss, the clinical significance of such small volumes is questionable. The overall usefulness of the various energy sources available will depend on a number of factors including vessel burst pressure and seal time, lateral thermal spread, and smoke production. Animal studies and laboratory-based trials are useful in providing a controlled environment to investigate such parameters. At present, there is insufficient evidence to support the use of one energy source over another. Copyright © 2013 AAGL. All rights reserved.

  4. Profiles of plasma parameters and density of negative hydrogen ions by laser detachment measurements in RF-driven ion sources

    International Nuclear Information System (INIS)

    Christ-Koch, Sina

    2007-01-01

    This work shows the application of the Laserdetachment method for spatially resolved measurements of negative Hydrogen/Deuterium ion density. It was applied on a high power low pressure RF-driven ion source. The Laser detachment method is based on the measurement of electron currents on a positively biased Langmuir probe before and during/after a laser pulse. The density ratio of negative ions to electrons can be derived from the ratio of currents to the probe. The absolute density of negative ions can be obtained when the electron density is measured with the standard Langmuir probe setup. Measurements with the Langmuir probe additionally yield information about the floating and plasma potential, the electron temperature and the density of positive ions. The Laser detachment setup had to be adapted to the special conditions of the RF-driven source. In particular the existence of RF fields (1 MHz), high source potential (-20 kV), magnetic fields (∝ 7 mT) and caesium inside the source had to be considered. The density of negative ions could be identified in the range of n(H - )=1.10 17 1/m 3 , which is in the same order of magnitude as the electron density. Only the application of the Laser detachment method with the Langmuir probe measurements will yield spatially resolved plasma parameters and H- density profiles. The influence of diverse external parameters, such as pressure, RF-power, magnetic fields on the plasma parameters and their profiles were studied and explained. Hence, the measurements lead to a detailed understanding of the processes inside the source. (orig.)

  5. Determination of discharge parameters via OES at the Linac4 H− ion source

    International Nuclear Information System (INIS)

    Briefi, S.; Fink, D.; Mattei, S.; Lettry, J.; Fantz, U.

    2016-01-01

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T e ≈ 1.2 eV, n e ≈ 1 × 10 19 m −3 , and n H /n H 2 ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients

  6. Fitting and benchmarking of Monte Carlo output parameters for iridium-192 high dose rate brachytherapy source

    International Nuclear Information System (INIS)

    Acquah, F.G.

    2011-01-01

    Brachytherapy, the use of radioactive sources for the treatment of tumours is an important tool in radiation oncology. Accurate calculations of dose delivered to malignant and normal tissues are the main responsibility of the Medical Physics staff. With the use of Treatment Planning System (TPS) computers now becoming a standard practice in the Radiation Oncology Departments, Independent calculations to certify the results of these commercial TPSs are important part of a good quality management system for brachytherapy implants. There are inherent errors in the dose distributions produced by these TPSs due to its failure to account for heterogeneity in the calculation algorithms and Monte Carlo (MC) method seems to be the panacea for these corrections. In this study, a fit functional form using MC output parameters was performed to reduce dose calculation uncertainty using the Matlab software curve fitting applications. This includes the modification of the AAPM TG-43 parameters to accommodate the new developments for a rapid brachytherapy dose rate calculation. Analytical computations were performed to hybridize the anisotropy function, F(r,θ) and radial dose function, g(r) into a single new function f(r,θ) for the Nucletron microSelectron High Dose Rate 'new or v2' (mHDRv2) 192 Ir brachytherapy source. In order to minimize computation time and to improve the accuracy of manual calculations, the dosimetry function f(r,θ) used fewer parameters and formulas for the fit. Using MC outputs as the standard, the percentage errors for the fits were calculated and used to evaluate the average and maximum uncertainties. Dose rate deviation between the MC data and fit were also quantified as errors(E), which showed minimal values. These results showed that the dosimetry parameters from this study as compared to those of MC outputs parameters were in good agreement and better than the results obtained from literature. The work confirms a lot of promise in building robust

  7. Solving seismological problems using SGRAPH program: I-source parameters and hypocentral location

    International Nuclear Information System (INIS)

    Abdelwahed, Mohamed F.

    2012-01-01

    SGRAPH program is considered one of the seismological programs that maintain seismic data. SGRAPH is considered unique for being able to read a wide range of data formats and manipulate complementary tools in different seismological subjects in a stand-alone Windows-based application. SGRAPH efficiently performs the basic waveform analysis and solves advanced seismological problems. The graphical user interface (GUI) utilities and the Windows facilities such as, dialog boxes, menus, and toolbars simplified the user interaction with data. SGRAPH supported the common data formats like, SAC, SEED, GSE, ASCII, and Nanometrics Y-format, and others. It provides the facilities to solve many seismological problems with the built-in inversion and modeling tools. In this paper, I discuss some of the inversion tools built-in SGRAPH related to source parameters and hypocentral location estimation. Firstly, a description of the SGRAPH program is given discussing some of its features. Secondly, the inversion tools are applied to some selected events of the Dahshour earthquakes as an example of estimating the spectral and source parameters of local earthquakes. In addition, the hypocentral location of these events are estimated using the Hypoinverse 2000 program operated by SGRAPH.

  8. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.; Yazvitsky, N. Yu.

    2004-05-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.

  9. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.; Yazvitsky, N.Yu.

    2004-01-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics

  10. American College of Radiology-American Brachytherapy Society practice parameter for electronically generated low-energy radiation sources.

    Science.gov (United States)

    Devlin, Phillip M; Gaspar, Laurie E; Buzurovic, Ivan; Demanes, D Jeffrey; Kasper, Michael E; Nag, Subir; Ouhib, Zoubir; Petit, Joshua H; Rosenthal, Seth A; Small, William; Wallner, Paul E; Hartford, Alan C

    This collaborative practice parameter technical standard has been created between the American College of Radiology and American Brachytherapy Society to guide the usage of electronically generated low energy radiation sources (ELSs). It refers to the use of electronic X-ray sources with peak voltages up to 120 kVp to deliver therapeutic radiation therapy. The parameter provides a guideline for utilizing ELS, including patient selection and consent, treatment planning, and delivery processes. The parameter reviews the published clinical data with regard to ELS results in skin, breast, and other cancers. This technical standard recommends appropriate qualifications of the involved personnel. The parameter reviews the technical issues relating to equipment specifications as well as patient and personnel safety. Regarding suggestions for educational programs with regard to this parameter,it is suggested that the training level for clinicians be equivalent to that for other radiation therapies. It also suggests that ELS must be done using the same standards of quality and safety as those in place for other forms of radiation therapy. Copyright © 2017 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. LIGHT SOURCE: A simulation study of Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Tang, Chuan-Xiang; Li, Ren-Kai; Huang, Wen-Hui; Chen, Huai-Bi; Du, Ying-Chao; Du, Qiang; Du, Tai-Bin; He, Xiao-Zhong; Hua, Jian-Fei; Lin, Yu-Zhen; Qian, Hou-Jun; Shi, Jia-Ru; Xiang, Dao; Yan, Li-Xin; Yu, Pei-Cheng

    2009-06-01

    Thomson scattering X-ray sources are compact and affordable facilities that produce short duration, high brightness X-ray pulses enabling new experimental capacities in ultra-fast science studies, and also medical and industrial applications. Such a facility has been built at the Accelerator Laboratory of Tsinghua University, and upgrade is in progress. In this paper, we present a proposed layout of the upgrade with design parameters by simulation, aiming at high X-ray pulses flux and brightness, and also enabling advanced dynamics studies and applications of the electron beam. Design and construction status of main subsystems are also presented.

  12. SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Reynoso, F [UT MD Anderson Cancer Center, Houston, TX (United States); Washington University School of Medicine, St. Louis, MO (United States); Munro, J [Source Production & Equipment Co., Inc., St. Rose, LA (United States); Cho, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

  13. Dose distribution and dosimetry parameters calculation of MED3633 Palladium-103 source in water phantom using MCNP

    International Nuclear Information System (INIS)

    Mowlavi, A. A.; Binesh, A.; Moslehitabar, H.

    2006-01-01

    Palladium-103 ( 103 Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103 Pd source is presented in this work. Materials and Methods: The dose distribution around the 10 3Pd Model MED3633 located in the center of 30*30*30 m 3 water phantom cube was calculated using MCNP code by the Monte Carlo method. The percentage depth dose variation along the different axis parallel and perpendicular to the source was also calculated. Then, the isodose curves for 100%, 75%, 50% and 25% percentage depth dose and dosimetry parameters of TG-43 protocol were determined. Results: The results show that the Monte Carlo Method could calculate dose deposition in high gradient region, near the source, accurately. The isodose curves and dosimetric characteristics obtained for MED3633 103 Pd source are in good agreement with published results. Conclusion: The isodose curves of the MED3633 103 Pd source have been derived form dose calculation by MCNP code. The calculated dosimetry parameters for the source agree quite well with their Monte Carlo calculated and experimental measurement values

  14. Model parameter estimations from residual gravity anomalies due to simple-shaped sources using Differential Evolution Algorithm

    Science.gov (United States)

    Ekinci, Yunus Levent; Balkaya, Çağlayan; Göktürkler, Gökhan; Turan, Seçil

    2016-06-01

    An efficient approach to estimate model parameters from residual gravity data based on differential evolution (DE), a stochastic vector-based metaheuristic algorithm, has been presented. We have showed the applicability and effectiveness of this algorithm on both synthetic and field anomalies. According to our knowledge, this is a first attempt of applying DE for the parameter estimations of residual gravity anomalies due to isolated causative sources embedded in the subsurface. The model parameters dealt with here are the amplitude coefficient (A), the depth and exact origin of causative source (zo and xo, respectively) and the shape factors (q and ƞ). The error energy maps generated for some parameter pairs have successfully revealed the nature of the parameter estimation problem under consideration. Noise-free and noisy synthetic single gravity anomalies have been evaluated with success via DE/best/1/bin, which is a widely used strategy in DE. Additionally some complicated gravity anomalies caused by multiple source bodies have been considered, and the results obtained have showed the efficiency of the algorithm. Then using the strategy applied in synthetic examples some field anomalies observed for various mineral explorations such as a chromite deposit (Camaguey district, Cuba), a manganese deposit (Nagpur, India) and a base metal sulphide deposit (Quebec, Canada) have been considered to estimate the model parameters of the ore bodies. Applications have exhibited that the obtained results such as the depths and shapes of the ore bodies are quite consistent with those published in the literature. Uncertainty in the solutions obtained from DE algorithm has been also investigated by Metropolis-Hastings (M-H) sampling algorithm based on simulated annealing without cooling schedule. Based on the resulting histogram reconstructions of both synthetic and field data examples the algorithm has provided reliable parameter estimations being within the sampling limits of

  15. Calculation of shielding parameters

    International Nuclear Information System (INIS)

    Montoya Z, J.

    1994-01-01

    With the propose of reduce the hazard to radiation, exist three basic factors: a) time, the time to exposition to working person inside to area, from exist determined speed the doses, is proportional of the time permanence; b) distance, the reduce to doses is inverse square of the distance to exposition point; c) building, consist to interpose between source and exposition point to material. The main aspect development to the analysis of parameters distance and building. The analysis consist to development of the mathematical implicit, in the model of source radioactive, beginning with the geometry to source, distance to exposition source, and configuration building. In the final part was realize one comparative studied to calculus of parameters to blinding, employs two codes CPBGAM and MICROSHIELD, the first made as part to work thesis. The point source its a good approximation to any one real source, but in the majority of the time to propose analysis the spatial distribution of the source must realized in explicit way. The buildings calculus in volumetry's source can be approximate begin's of plan as source adaptations. It's important to have present that not only the building exist the exposition to the radiation, and the parameters time and distance plays an important paper too. (Author)

  16. A Sensitivity Study for an Evaluation of Input Parameters Effect on a Preliminary Probabilistic Tsunami Hazard Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Hyun-Me; Kim, Min Kyu; Choi, In-Kil [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Sheen, Dong-Hoon [Chonnam National University, Gwangju (Korea, Republic of)

    2014-10-15

    The tsunami hazard analysis has been based on the seismic hazard analysis. The seismic hazard analysis has been performed by using the deterministic method and the probabilistic method. To consider the uncertainties in hazard analysis, the probabilistic method has been regarded as attractive approach. The various parameters and their weight are considered by using the logic tree approach in the probabilistic method. The uncertainties of parameters should be suggested by analyzing the sensitivity because the various parameters are used in the hazard analysis. To apply the probabilistic tsunami hazard analysis, the preliminary study for the Ulchin NPP site had been performed. The information on the fault sources which was published by the Atomic Energy Society of Japan (AESJ) had been used in the preliminary study. The tsunami propagation was simulated by using the TSUNAMI{sub 1}.0 which was developed by Japan Nuclear Energy Safety Organization (JNES). The wave parameters have been estimated from the result of tsunami simulation. In this study, the sensitivity analysis for the fault sources which were selected in the previous studies has been performed. To analyze the effect of the parameters, the sensitivity analysis for the E3 fault source which was published by AESJ was performed. The effect of the recurrence interval, the potential maximum magnitude, and the beta were suggested by the sensitivity analysis results. Level of annual exceedance probability has been affected by the recurrence interval.. Wave heights have been influenced by the potential maximum magnitude and the beta. In the future, the sensitivity analysis for the all fault sources in the western part of Japan which were published AESJ would be performed.

  17. Comparison of parameters affecting GNP-loaded choroidal melanoma dosimetry; Monte Carlo study

    Science.gov (United States)

    Sharabiani, Marjan; Asadi, Somayeh; Barghi, Amir Rahnamai; Vaezzadeh, Mehdi

    2018-04-01

    The current study reports the results of tumor dosimetry in the presence of gold nanoparticles (GNPs) with different sizes and concentrations. Due to limited number of works carried out on the brachytherapy of choroidal melanoma in combination with GNPs, this study was performed to determine the optimum size and concentration for GNPs which contributes the highest dose deposition in tumor region, using two phantom test cases namely water phantom and a full Monte Carlo model of human eye. Both water and human eye phantoms were simulated with MCNP5 code. Tumor dosimetry was performed for a typical point photon source with an energy of 0.38 MeV as a high energy source and 103Pd brachytherapy source with an average energy of 0.021 MeV as a low energy source in water phantom and eye phantom respectively. Such a dosimetry was done for different sizes and concentrations of GNPs. For all of the diameters, increase in concentration of GNPs resulted in an increase in dose deposited in the region of interest. In a certain concentration, GNPs with larger diameters contributed more dose to the tumor region, which was more pronounced using eye phantom. 100 nm was reported as the optimum size in order to achieve the highest energy deposition within the target. This work investigated the optimum parameters affecting macroscopic dose enhancement in GNP-aided brachytherapy of choroidal melanoma. The current work also had implications on using low energy photon sources in the presence of GNPs to acquire the highest dose enhancement. This study is conducted through four different sizes and concentrations of GNPs. Considering the sensitivity of human eye tissue, in order to report the precise optimum parameters affecting radiosensitivity, a comprehensive study on a wide range of sizes and concentrations are required.

  18. Study and characterization of a phosphorous ion source and development of a emittancemeter suited to multi-beam ion sources

    International Nuclear Information System (INIS)

    Hoang Gia Tuong.

    1982-12-01

    The ionization process which is used is the electronic bombardment. Phosphorus choice for the source experimentation is motivated by its principal destination: ionic implantation. Heavy ion applications are also quoted. Operating conditions allowing good results to be obtained are determined after a study of different parameters such as the electron current, the neutron pressure and the extraction voltage: the ion current obtained is of the order of mA. The source emittance, representing the quality of the ionic beam, is measured by a method suited to multibeam sources [fr

  19. Comparison of earthquake source parameters and interseismic plate coupling variations in global subduction zones (Invited)

    Science.gov (United States)

    Bilek, S. L.; Moyer, P. A.; Stankova-Pursley, J.

    2010-12-01

    Geodetically determined interseismic coupling variations have been found in subduction zones worldwide. These coupling variations have been linked to heterogeneities in interplate fault frictional conditions. These connections to fault friction imply that observed coupling variations are also important in influencing details in earthquake rupture behavior. Because of the wealth of newly available geodetic models along many subduction zones, it is now possible to examine detailed variations in coupling and compare to seismicity characteristics. Here we use a large catalog of earthquake source time functions and slip models for moderate to large magnitude earthquakes to explore these connections, comparing earthquake source parameters with available models of geodetic coupling along segments of the Japan, Kurile, Kamchatka, Peru, Chile, and Alaska subduction zones. In addition, we use published geodetic results along the Costa Rica margin to compare with source parameters of small magnitude earthquakes recorded with an onshore-offshore network of seismometers. For the moderate to large magnitude earthquakes, preliminary results suggest a complex relationship between earthquake parameters and estimates of strongly and weakly coupled segments of the plate interface. For example, along the Kamchatka subduction zone, these earthquakes occur primarily along the transition between strong and weak coupling, with significant heterogeneity in the pattern of moment scaled duration with respect to the coupling estimates. The longest scaled duration event in this catalog occurred in a region of strong coupling. Earthquakes along the transition between strong and weakly coupled exhibited the most complexity in the source time functions. Use of small magnitude (0.5 earthquake spectra, with higher corner frequencies and higher mean apparent stress for earthquakes that occur in along the Osa Peninsula relative to the Nicoya Peninsula, mimicking the along-strike variations in

  20. Reducing fluxes of faecal indicator compliance parameters to bathing waters from diffuse agricultural sources: The Brighouse Bay study, Scotland

    International Nuclear Information System (INIS)

    Kay, D.; Aitken, M.; Crowther, J.; Dickson, I.; Edwards, A.C.; Francis, C.; Hopkins, M.; Jeffrey, W.; Kay, C.; McDonald, A.T.; McDonald, D.; Stapleton, C.M.; Watkins, J.; Wilkinson, J.; Wyer, M.D.

    2007-01-01

    The European Water Framework Directive requires the integrated management of point and diffuse pollution to achieve 'good' water quality in 'protected areas'. These include bathing waters, which are regulated using faecal indicator organisms as compliance parameters. Thus, for the first time, European regulators are faced with the control of faecal indicator fluxes from agricultural sources where these impact on bathing water compliance locations. Concurrently, reforms to the European Union (EU) Common Agricultural Policy offer scope for supporting on-farm measures producing environmental benefits through the new 'single farm payments' and the concept of 'cross-compliance'. This paper reports the first UK study involving remedial measures, principally stream bank fencing, designed to reduce faecal indicator fluxes at the catchment scale. Considerable reduction in faecal indicator flux was observed, but this was insufficient to ensure bathing water compliance with either Directive 76/160/EEC standards or new health-evidence-based criteria proposed by WHO and the European Commission. - Diffuse microbiological pollution from farming activities can be reduced by protected riparian zones

  1. The SSI TOOLBOX Source Term Model SOSIM - Screening for important radionuclides and parameter sensitivity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Avila Moreno, R.; Barrdahl, R.; Haegg, C.

    1995-05-01

    The main objective of the present study was to carry out a screening and a sensitivity analysis of the SSI TOOLBOX source term model SOSIM. This model is a part of the SSI TOOLBOX for radiological impact assessment of the Swedish disposal concept for high-level waste KBS-3. The outputs of interest for this purpose were: the total released fraction, the time of total release, the time and value of maximum release rate, the dose rates after direct releases of the biosphere. The source term equations were derived and simple equations and methods were proposed for calculation of these. A literature survey has been performed in order to determine a characteristic variation range and a nominal value for each model parameter. In order to reduce the model uncertainties the authors recommend a change in the initial boundary condition for solution of the diffusion equation for highly soluble nuclides. 13 refs.

  2. Study of hot electrons in a ECR ion source

    International Nuclear Information System (INIS)

    Barue, C.

    1992-12-01

    The perfecting of diagnosis connected with hot electrons of plasma, and then the behaviour of measured parameters of plasma according to parameters of source working are the purpose of this thesis. The experimental results obtained give new information on hot electrons of an ECR ion source. This thesis is divided in 4 parts: the first part presents an ECR source and the experimental configuration (ECRIS physics, minimafios GHz, diagnosis used); the second part, the diagnosis (computer code of cyclotron emission and calibration); the third part gives experimental results in continuous regime (emission cyclotron diagnosis, bremsstrahlung); the fourth part, experimental results in pulsed regime (emission cyclotron diagnosis, diamagnetism) calibration)

  3. Determination of a PWR key neutron parameters uncertainties and conformity studies applications

    International Nuclear Information System (INIS)

    Bernard, D.

    2002-01-01

    The aim of this thesis was to evaluate uncertainties of key neutron parameters of slab reactors. Uncertainties sources have many origins, technologic origin for parameters of fabrication and physical origin for nuclear data. First, each contribution of uncertainties is calculated and finally, a factor of uncertainties is associated to key slab parameter like reactivity, isotherm reactivity coefficient, control rod efficiency, power form factor before irradiation and lifetime. This factors of uncertainties were computed by Generalized Perturbations Theory in case of step 0 and by directs calculations in case of irradiation problems. One of neutronic conformity applications was about fabrication and nuclear data targets precision adjustments. Statistic (uncertainties) and deterministic (deviations) approaches were studied. Then neutronics key slab parameters uncertainties were reduced and so nuclear performances were optimised. (author)

  4. Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo method

    International Nuclear Information System (INIS)

    Oliveira, Tiago Batista de

    2016-01-01

    Expectations of the World Health Organization for the year 2030 are that the number of cancer deaths is approximately 13.2 million, reflecting the high proportion of this disease in global health issue. With respect to prostate cancer, according to the National Cancer Institute, the number of cases diagnosed worldwide in 2012 was approximately 1.1 million, while in Brazil the data demonstrated the incidence of 68,000 new cases. The treatment of cancer can be performed with surgery (prostatectomy) or radiation therapy. Among radiotherapy, we can highlight the brachytherapy technique, which consists in the introduction of small radioactive sources (seeds) within the prostate, which is delivered a high dose value in the treatment volume and low dose in the surrounding tissues. In Brazil, the medical profession estimates a demand of approximately 8000 seeds / month, and the unit cost of each seed at least US $ 26.00. The AAPM protocol TG-43 recommend the dose-rate constant, radial dose function and anisotropy function for dosimetric analysis LDR brachytherapy seeds. In this work, Monte Carlo simulations were performed in order to assess the dosimetric parameters of the OncoSeed-6711, manufactured by Oncura-GEHealthcare, and a seed developed by Radiation Technology Center, using the MCNP5 code. A 6711 seed, an IPEN seed and the 30 x 30 x 30cm 3 phantom filled with water were modeled to simulate the dose distribution. The 6711 seed parameters were compared with literature, and the results presented relative error less than 0.1% for Λ. In comparison with the 6711 seed, the IPEN model seed dosimetric parameters were similar, account the statistical uncertainty. (author)

  5. Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Okuda, S.; Nishioka, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2013-09-14

    Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H{sup −} extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases.

  6. Effect of basic physical parameters to control plasma meniscus and beam halo formation in negative ion sources

    International Nuclear Information System (INIS)

    Miyamoto, K.; Okuda, S.; Nishioka, S.; Hatayama, A.

    2013-01-01

    Our previous study shows that the curvature of the plasma meniscus causes the beam halo in the negative ion sources: the negative ions extracted from the periphery of the meniscus are over-focused in the extractor due to the electrostatic lens effect, and consequently become the beam halo. In this article, the detail physics of the plasma meniscus and beam halo formation is investigated with two-dimensional particle-in-cell simulation. It is shown that the basic physical parameters such as the H − extraction voltage and the effective electron confinement time significantly affect the formation of the plasma meniscus and the resultant beam halo since the penetration of electric field for negative ion extraction depends on these physical parameters. Especially, the electron confinement time depends on the characteristic time of electron escape along the magnetic field as well as the characteristic time of electron diffusion across the magnetic field. The plasma meniscus penetrates deeply into the source plasma region when the effective electron confinement time is short. In this case, the curvature of the plasma meniscus becomes large, and consequently the fraction of the beam halo increases

  7. ATLAS parameter study

    International Nuclear Information System (INIS)

    Adler, R.J.

    1994-01-01

    The purpose of this study is to make an independent assessment on the parameters chosen for the ATLAS capacitor bank at LANL. The contractor will perform a study of the basic pulsed power parameters of the ATLAS device with baseline functional parameters of >25 MA implosion current and <2.5 microsecond current risetime. Nominal circuit parameters held fixed will be the 14 nH from the vacuum interface to the load, and the nominal load impedances of 1 milliohm for slow loads and 10 milliohms for fast loads. Single Ended designs, as opposed to bipolar designs, will be studied in detail. The ATLAS pulsed power design problem is about inductance. The reason that a 36 MJ bank is required is that such a bank has enough individual capacitors so that the parallel inductance is acceptably low. Since about half the inductance is in the bank, and the inductance and time constant of the submodules is fixed, the variation of output with a given parameter will generally be a weak one. In general, the dl/dt calculation demonstrates that for the real system inductances, 700 kV is the optimum voltage for the bank to drive X-ray loads. The optimum is broad, and there is little reduction in performance at voltages as low as 450 kV. The direct drive velocity analysis also shows that the optimum velocity is between 480 and 800 kV for a variety of assumptions, and that there is less than a 10% variation in velocity over this range. Voltages in the 120 kV--600 kV range are desirable for driving heavy liners. A compromise optimum operating point might be 480 kV, at which all X-ray operation scenarios are within 10% of their velocity optimum, and heavy liners can be configured to be near optimum if small enough. Based on very preliminary studies the author believes that the choice of a single operating voltage point (say, 480 kV) is unnecessary, and that a bank engineered for dual operation at 480 and 240 kV will be the best solution to the ATLAS problem

  8. Evaluation of Microbiological and Physicochemical Parameters of Alternative Source of Drinking Water: A Case Study of Nzhelele River, South Africa.

    Science.gov (United States)

    Edokpayi, Joshua N; Odiyo, John O; Popoola, Elizabeth O; Msagati, Titus A M

    2018-01-01

    Access to clean and safe drinking water is still a problem in developing countries and more pronounced in rural areas. Due to erratic supply of potable, rural dwellers often seek for an alternative source of water to meet their basic water needs. The objective of this study is to monitor the microbiological and physicochemical water quality parameters of Nzhelele River which is a major alternative source of drinking water to villages along its course in Limpopo province of South Africa. Membrane filtration method was employed in evaluating the levels of E. coli and Enterococci in the river water from January-June, 2014. Specialized multimeter was used to measure the pH, electrical conductivity and turbidity of the river water. Ion Chromatograph was used to measure major anions such as fluoride, chloride, nitrate and sulphate in the water. High levels of E. coli (1 x 10 2 - 8 x 10 4 cfu/100 mL) and enterococci (1 x 10 2 - 5.7 x 10 3 cfu/100 mL) were found in the river water and exceeded their permissible limits of 0 cfu/100 mL for drinking water. Turbidity values ranged from 1.12-739.9 NTU. The pH, electrical conductivity, chloride, fluoride, nitrate and sulphate levels were below their permissible limits for drinking water. The river water is contaminated with faecal organisms and is unfit for drinking purposes. However, the levels of the major anions accessed were within the permissible limits of drinking water.

  9. An experimental study of symmetric and asymmetric peak-fitting parameters for alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Martin Sanchez, A.; Vera Tome, F.; Caceres Marzal, D.; Bland, C.J.

    1994-01-01

    A pulse-height spectrum of alpha-particle emissions at discrete energies can be fitted by the peak-shape functions generated by combining asymmetric truncated exponential functions with a symmetric Gaussian distribution. These functions have been applied successfully by several workers. A correlation was previously found between the variance of the symmetric Gaussian portion of the fitting function, and the parameter characterising the principal exponential tailing function. The results of a more detailed experimental study are reported, which involve varying the angle and the distance between the source and the detector. This analysis shows that the parameters of the symmetric and asymmetric parts of the fitted functions seem to depend on either the detector or the source. These parameters are influenced by the energy loss suffered by the alpha-particles as well as by the efficiency of charge collection in the solid-state detector. (orig.)

  10. Brachytherapy dosimetry parameters calculated for a 131Cs source

    International Nuclear Information System (INIS)

    Rivard, Mark J.

    2007-01-01

    A comprehensive analysis of the IsoRay Medical model CS-1 Rev2 131 Cs brachytherapy source was performed. Dose distributions were simulated using Monte Carlo methods (MCNP5) in liquid water, Solid TM , and Virtual Water TM spherical phantoms. From these results, the in-water brachytherapy dosimetry parameters have been determined, and were compared with those of Murphy et al. [Med. Phys. 31, 1529-1538 (2004)] using measurements and simulations. Our results suggest that calculations obtained using erroneous cross-section libraries should be discarded as recommended by the 2004 AAPM TG-43U1 report. Our MC Λ value of 1.046±0.019 cGy h -1 U -1 is within 1.3% of that measured by Chen et al. [Med. Phys. 32, 3279-3285 (2005)] using TLDs and the calculated results of Wittman and Fisher [Med. Phys. 34, 49-54 (2007)] using MCNP5. Using the discretized energy approach of Rivard [Appl. Radiat. Isot. 55, 775-782 (2001)] to ascertain the impact of individual 131 Cs photons on radial dose function and anisotropy functions, there was virtual equivalence of results for 29.461≤E γ ≤34.419 keV and for a mono-energetic 30.384 keV photon source. Comparisons of radial dose function and 2D anisotropy function data are also included, and an analysis of material composition and cross-section libraries was performed

  11. Overview of the relations earthquake source parameters and the specification of strong ground motion for design purposes

    International Nuclear Information System (INIS)

    Bernreuter, D.L.

    1977-08-01

    One of the most important steps in the seismic design process is the specification of the appropriate ground motion to be input into the design analysis. From the point-of-view of engineering design analysis, the important parameters are peak ground acceleration, spectral shape and peak spectral levels. In a few cases, ground displacement is a useful parameter. The earthquake is usually specified by giving its magnitude and either the epicentral distance or the distance of the closest point on the causitive fault to the site. Typically, the appropriate ground motion parameters are obtained using the specified magnitude and distance in equations obtained from regression analysis among the appropriate variables. Two major difficulties with such an approach are: magnitude is not the best parameter to use to define the strength of an earthquake, and little near-field data is available to establish the appropriate form for the attenuation of the ground motion with distance, source size and strength. These difficulties are important for designing a critical facility; i.e., one for which a very low risk of exceeding the design ground motion is required. Examples of such structures are nuclear power plants, schools and hospitals. for such facilities, a better understanding of the relation between the ground motion and the important earthquake source parameters could be very useful for several reasons

  12. Opinions on Drug Interaction Sources in Anticancer Treatments and Parameters for an Oncology-Specific Database by Pharmacy Practitioners in Asia

    Directory of Open Access Journals (Sweden)

    2010-01-01

    Full Text Available Cancer patients undergoing chemotherapy are particularly susceptible to drug-drug interactions (DDIs. Practitioners should keep themselves updated with the most current DDI information, particularly involving new anticancer drugs (ACDs. Databases can be useful to obtain up-to-date DDI information in a timely and efficient manner. Our objective was to investigate the DDI information sources of pharmacy practitioners in Asia and their views on the usefulness of an oncology-specific database for ACD interactions. A qualitative, cross-sectional survey was done to collect information on the respondents' practice characteristics, sources of DDI information and parameters useful in an ACD interaction database. Response rate was 49%. Electronic databases (70%, drug interaction textbooks (69% and drug compendia (64% were most commonly used. Majority (93% indicated that a database catering towards ACD interactions was useful. Essential parameters that should be included in the database were the mechanism and severity of the detected interaction, and the presence of a management plan (98% each. This study has improved our understanding on the usefulness of various DDI information sources for ACD interactions among pharmacy practitioners in Asia. An oncology-specific DDI database targeting ACD interactions is definitely attractive for clinical practice.

  13. Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

    International Nuclear Information System (INIS)

    Moura, Eduardo Santana de

    2011-01-01

    The use of brachytherapy technique with iodine-125 seeds to prostate cancer treatment has been used for decades with good clinical outcomes. To aim the Brazilian population necessities, IPEN-CNEN/SP developed the iodine-125 seed prototype with national technology. The objectives of this work are the development and the study of dosimetric procedures associates with the experimental acquisition of the useful parameters for the iodine-125 dosimetric characterization and to evaluate if the developed procedures, in this work, have the basic conditions to determinate the dosimetric analysis, that are fundamental for clinical procedures. The dosimeters selected for the analysis are the TLD-100 (LiF:Mg,Ti), initially these dosimeters were submitted for two selection steps to choose the dosimeters more reproducible for the dosimetric analysis. The two steps were the selection by the mass of the dosimeters and the reproducibility after four irradiation series in a Cobalt-60 irradiator (CTR-IPEN). Afterwards these steps, the dosimeters were irradiated in linear accelerator with 6 MV energy (Service of Radiotherapy - Hospital Israelita Albert Einstein) to yield the individual calibration factors to each dosimeter. After, the dosimeters were used to the irradiations with iodine-125 seed, 6711 model, (GE-Healthcare). The irradiations and others analysis with iodine-125 seeds yield the useful values for the determination of the parameters suggested by the AAPM (American Association of Physicists in Medicine): constant of dose rate, geometry function, dose radial function and anisotropy function. The results showed good agreement with the values published by the literature, for the same iodine- 125 model, this fact confirms that the realized parameters will be able to be used for the IPEN-CNEN iodine-125 seeds dosimetry and quality control. (author)

  14. A study of calculation methodology and experimental measurements of the kinetic parameters for source driven subcritical systems

    International Nuclear Information System (INIS)

    Lee, Seung Min

    2009-01-01

    This work presents a theoretical study of reactor kinetics focusing on the methodology of calculation and the experimental measurements of the so-called kinetic parameters. A comparison between the methodology based on the Dulla's formalism and the classical method is made. The objective is to exhibit the dependence of the parameters on subcriticality level and perturbation. Two different slab type systems were considered: thermal one and fast one, both with homogeneous media. One group diffusion model was used for the fast reactor, and for the thermal system, two groups diffusion model, considering, in both case, only one precursor's family. The solutions were obtained using the expansion method. Also, descriptions of the main experimental methods of measurements of the kinetic parameters are presented in order to put a question about the compatibility of these methods in subcritical region. (author)

  15. Determination of discharge parameters via OES at the Linac4 H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Briefi, S., E-mail: stefan.briefi@physik.uni-augsburg.de [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Fink, D.; Mattei, S.; Lettry, J. [Linac4 Ion Source Team, CERN-ABP, 1211 Geneva 23 (Switzerland); Fantz, U. [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany)

    2016-02-15

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T{sub e} ≈ 1.2 eV, n{sub e} ≈ 1 × 10{sup 19} m{sup −3}, and n{sub H}/n{sub H{sub 2}} ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients.

  16. Computation of rectangular source integral by rational parameter polynomial method

    International Nuclear Information System (INIS)

    Prabha, Hem

    2001-01-01

    Hubbell et al. (J. Res. Nat Bureau Standards 64C, (1960) 121) have obtained a series expansion for the calculation of the radiation field generated by a plane isotropic rectangular source (plaque), in which leading term is the integral H(a,b). In this paper another integral I(a,b), which is related with the integral H(a,b) has been solved by the rational parameter polynomial method. From I(a,b), we compute H(a,b). Using this method the integral I(a,b) is expressed in the form of a polynomial of a rational parameter. Generally, a function f (x) is expressed in terms of x. In this method this is expressed in terms of x/(1+x). In this way, the accuracy of the expression is good over a wide range of x as compared to the earlier approach. The results for I(a,b) and H(a,b) are given for a sixth degree polynomial and are found to be in good agreement with the results obtained by numerically integrating the integral. Accuracy could be increased either by increasing the degree of the polynomial or by dividing the range of integration. The results of H(a,b) and I(a,b) are given for values of b and a up to 2.0 and 20.0, respectively

  17. Design parameters for a small storage ring optimized as an x-ray lithography source

    International Nuclear Information System (INIS)

    Grobman, W.D.

    1983-01-01

    This paper examines the design parameters for a ''compact storage ring'' which is matched well to x-ray lithographic requirements, but is as small as possible. This calculation uses a model of a lithographic system which obtains its input parameters from a technology of mask, resist and beam line based on the IBM program at the Brookhaven National Laboratory vacuum ultraviolet electron storage ring. Based on this lithographic system, we model exposure throughput as a function of storage ring parameters to understand which storage ring designs provide adequate but not excessive soft x-ray flux in the lithographically important region. Our scan of storage ring sources will cover a wide range of energies and magnetic fields, to permit consideration of superconducting as well as more standard strong- or weak-focusing designs. Furthermore, we will show that the results of the calculations presented here can be scaled in a simple way to cover a wide range of x-ray lithography system assumptions

  18. Empirical Scaling Relations of Source Parameters For The Earthquake Swarm 2000 At Novy Kostel (vogtland/nw-bohemia)

    Science.gov (United States)

    Heuer, B.; Plenefisch, T.; Seidl, D.; Klinge, K.

    Investigations on the interdependence of different source parameters are an impor- tant task to get more insight into the mechanics and dynamics of earthquake rup- ture, to model source processes and to make predictions for ground motion at the surface. The interdependencies, providing so-called scaling relations, have often been investigated for large earthquakes. However, they are not commonly determined for micro-earthquakes and swarm-earthquakes, especially for those of the Vogtland/NW- Bohemia region. For the most recent swarm in the Vogtland/NW-Bohemia, which took place between August and December 2000 near Novy Kostel (Czech Republic), we systematically determine the most important source parameters such as energy E0, seismic moment M0, local magnitude ML, fault length L, corner frequency fc and rise time r and build their interdependencies. The swarm of 2000 is well suited for such investigations since it covers a large magnitude interval (1.5 ML 3.7) and there are also observations in the near-field at several stations. In the present paper we mostly concentrate on two near-field stations with hypocentral distances between 11 and 13 km, namely WERN (Wernitzgrün) and SBG (Schönberg). Our data processing includes restitution to true ground displacement and rotation into the ray-based prin- cipal co-ordinate system, which we determine by the covariance matrix of the P- and S-displacement, respectively. Data preparation, determination of the distinct source parameters as well as statistical interpretation of the results will be exemplary pre- sented. The results will be discussed with respect to temporal variations in the swarm activity (the swarm consists of eight distinct sub-episodes) and already existing focal mechanisms.

  19. Integrated source-risk model for radon: A definition study

    International Nuclear Information System (INIS)

    Laheij, G.M.H.; Aldenkamp, F.J.; Stoop, P.

    1993-10-01

    The purpose of a source-risk model is to support policy making on radon mitigation by comparing effects of various policy options and to enable optimization of counter measures applied to different parts of the source-risk chain. There are several advantages developing and using a source-risk model: risk calculations are standardized; the effects of measures applied to different parts of the source-risk chain can be better compared because interactions are included; and sensitivity analyses can be used to determine the most important parameters within the total source-risk chain. After an inventory of processes and sources to be included in the source-risk chain, the models presently available in the Netherlands are investigated. The models were screened for completeness, validation and operational status. The investigation made clear that, by choosing for each part of the source-risk chain the most convenient model, a source-risk chain model for radon may be realized. However, the calculation of dose out of the radon concentrations and the status of the validation of most models should be improved. Calculations with the proposed source-risk model will give estimations with a large uncertainty at the moment. For further development of the source-risk model an interaction between the source-risk model and experimental research is recommended. Organisational forms of the source-risk model are discussed. A source-risk model in which only simple models are included is also recommended. The other models are operated and administrated by the model owners. The model owners execute their models for a combination of input parameters. The output of the models is stored in a database which will be used for calculations with the source-risk model. 5 figs., 15 tabs., 7 appendices, 14 refs

  20. Prediction of broadband ground-motion time histories: Hybrid low/high-frequency method with correlated random source parameters

    Science.gov (United States)

    Liu, P.; Archuleta, R.J.; Hartzell, S.H.

    2006-01-01

    We present a new method for calculating broadband time histories of ground motion based on a hybrid low-frequency/high-frequency approach with correlated source parameters. Using a finite-difference method we calculate low- frequency synthetics (structure. We also compute broadband synthetics in a 1D velocity model using a frequency-wavenumber method. The low frequencies from the 3D calculation are combined with the high frequencies from the 1D calculation by using matched filtering at a crossover frequency of 1 Hz. The source description, common to both the 1D and 3D synthetics, is based on correlated random distributions for the slip amplitude, rupture velocity, and rise time on the fault. This source description allows for the specification of source parameters independent of any a priori inversion results. In our broadband modeling we include correlation between slip amplitude, rupture velocity, and rise time, as suggested by dynamic fault modeling. The method of using correlated random source parameters is flexible and can be easily modified to adjust to our changing understanding of earthquake ruptures. A realistic attenuation model is common to both the 3D and 1D calculations that form the low- and high-frequency components of the broadband synthetics. The value of Q is a function of the local shear-wave velocity. To produce more accurate high-frequency amplitudes and durations, the 1D synthetics are corrected with a randomized, frequency-dependent radiation pattern. The 1D synthetics are further corrected for local site and nonlinear soil effects by using a 1D nonlinear propagation code and generic velocity structure appropriate for the site’s National Earthquake Hazards Reduction Program (NEHRP) site classification. The entire procedure is validated by comparison with the 1994 Northridge, California, strong ground motion data set. The bias and error found here for response spectral acceleration are similar to the best results that have been published by

  1. Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

    Science.gov (United States)

    Koshti, Ajay M.

    2014-01-01

    Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

  2. Langmuir probe studies on a RF ion source for NBI

    International Nuclear Information System (INIS)

    McNeely, P.; Heineman, B.; Kraus, W.; Riedl, R.; Speth, E.; Vollmer, O.

    2001-01-01

    IPP Garching has been developing a RF ion source for H - production. In order to improve the data quality a new scanning probe system with passive RF compensation has been installed on the Type VI ion source on the BATMAN test stand. Using this probe, measurements have been carried out to study changes to the plasma parameters (electron density, electron temperature, and plasma potential) due to variation in the source operating conditions. The data were collected at a source pressure of 0.5 Pa and with 60±5 kW applied RF power. Presented are some of the results of these measurements, focusing on the effect of: argon seeding, addition of Cs to the source, and the newly added Faraday screen. The electron density behaves in a fashion that agrees with the theory of ambipolar diffusion. Typically there is little change to the average electron energy observed regardless of which effect is considered. The plasma potential shows the most significant changes with external source conditions, both in value for all cases and shape when the Faraday screen was added

  3. Studying the noise parameters of thin-film silicon resistors

    International Nuclear Information System (INIS)

    Belogurov, S.V.; Gostilo, V.V.; Yurov, A.S.

    1986-01-01

    The results of studies on spectral density and energy noise equivalent of thin-film resistors on the base of amorphous silicon and KIM and KVM commercial high-ohmic resistors are presented. Dependence of the active part of impedance on frequency is shown to be the main source of redundant noise in resistors. Dependence of spectral density of noise voltage of current noises of silicon resistors on applied voltage is described by the formula S T =B V 2 /f 1.6 with the values B=(1.4-1.7)x10 -12 Hz 0.6 . As to noise parameters the silicon resistor is superior to commercial resistors

  4. Source parameters of the M 6.5 Skyros Island (North Aegean Sea earthquake of July 26, 2001

    Directory of Open Access Journals (Sweden)

    A. Kiratzi

    2002-06-01

    Full Text Available Teleseismic body wave modelling, time domain moment tensor inversion of regional waveforms and spectral analysis of the far-field P-wave pulses are used to derive the source parameters of the July 26, 2001 Skyros earthquake (M 6.5. Its epicentre is located south of the Sporades Islands in the North Aegean Sea (Greece. Previous focal mechanism solutions indicate motion on strike-slip faults. The time domain moment tensor inversion is applied for the first time to the regional waveforms of the recently established broadband network in Greece. Its application gave results which are highly consistent with teleseismic waveform modelling. The results of this study, in combination with the distribution of aftershocks, indicate left-lateral strike slip motion on a NW-SE striking fault with parameters: fault plane (strike = 151°, dip = 83°, rake = 7° and auxiliary plane (strike = 60°, dip = 84°, rake = 173°, depth 12 km and M 0 = 5.98e18 N m. Moreover, the time domain moment tensor inversion technique yielded a pure double couple source with negligible CLVD. The spectral analysis of the far-field P-wave pulses resulted in a fault length L ~ 32 km, stress drop ~ 9 bars and average displacement u ~ 30 cm.These values are in very good agreement with those estimated from empirical scaling relations applicable to the Aegean area.

  5. SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

    International Nuclear Information System (INIS)

    Simiele, S; Palmer, B; DeWerd, L

    2016-01-01

    Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent"® electronic brachytherapy source (Axxent"® source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent"® source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent"® source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent"® source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent"® source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft Inc. (a subsidiary of i

  6. The Slip Behavior and Source Parameters for Spontaneous Slip Events on Rough Faults Subjected to Slow Tectonic Loading

    Science.gov (United States)

    Tal, Yuval; Hager, Bradford H.

    2018-02-01

    We study the response to slow tectonic loading of rough faults governed by velocity weakening rate and state friction, using a 2-D plane strain model. Our numerical approach accounts for all stages in the seismic cycle, and in each simulation we model a sequence of two earthquakes or more. We focus on the global behavior of the faults and find that as the roughness amplitude, br, increases and the minimum wavelength of roughness decreases, there is a transition from seismic slip to aseismic slip, in which the load on the fault is released by more slip events but with lower slip rate, lower seismic moment per unit length, M0,1d, and lower average static stress drop on the fault, Δτt. Even larger decreases with roughness are observed when these source parameters are estimated only for the dynamic stage of the rupture. For br ≤ 0.002, the source parameters M0,1d and Δτt decrease mutually and the relationship between Δτt and the average fault strain is similar to that of a smooth fault. For faults with larger values of br that are completely ruptured during the slip events, the average fault strain generally decreases more rapidly with roughness than Δτt.

  7. Identification of Evidence for Key Parameters in Decision-Analytic Models of Cost Effectiveness: A Description of Sources and a Recommended Minimum Search Requirement.

    Science.gov (United States)

    Paisley, Suzy

    2016-06-01

    This paper proposes recommendations for a minimum level of searching for data for key parameters in decision-analytic models of cost effectiveness and describes sources of evidence relevant to each parameter type. Key parameters are defined as treatment effects, adverse effects, costs, resource use, health state utility values (HSUVs) and baseline risk of events. The recommended minimum requirement for treatment effects is comprehensive searching according to available methodological guidance. For other parameter types, the minimum is the searching of one bibliographic database plus, where appropriate, specialist sources and non-research-based and non-standard format sources. The recommendations draw on the search methods literature and on existing analyses of how evidence is used to support decision-analytic models. They take account of the range of research and non-research-based sources of evidence used in cost-effectiveness models and of the need for efficient searching. Consideration is given to what constitutes best evidence for the different parameter types in terms of design and scientific quality and to making transparent the judgments that underpin the selection of evidence from the options available. Methodological issues are discussed, including the differences between decision-analytic models of cost effectiveness and systematic reviews when searching and selecting evidence and comprehensive versus sufficient searching. Areas are highlighted where further methodological research is required.

  8. Application of Time-series Model to Predict Groundwater Quality Parameters for Agriculture: (Plain Mehran Case Study)

    Science.gov (United States)

    Mehrdad Mirsanjari, Mir; Mohammadyari, Fatemeh

    2018-03-01

    Underground water is regarded as considerable water source which is mainly available in arid and semi arid with deficient surface water source. Forecasting of hydrological variables are suitable tools in water resources management. On the other hand, time series concepts is considered efficient means in forecasting process of water management. In this study the data including qualitative parameters (electrical conductivity and sodium adsorption ratio) of 17 underground water wells in Mehran Plain has been used to model the trend of parameters change over time. Using determined model, the qualitative parameters of groundwater is predicted for the next seven years. Data from 2003 to 2016 has been collected and were fitted by AR, MA, ARMA, ARIMA and SARIMA models. Afterward, the best model is determined using information criterion or Akaike (AIC) and correlation coefficient. After modeling parameters, the map of agricultural land use in 2016 and 2023 were generated and the changes between these years were studied. Based on the results, the average of predicted SAR (Sodium Adsorption Rate) in all wells in the year 2023 will increase compared to 2016. EC (Electrical Conductivity) average in the ninth and fifteenth holes and decreases in other wells will be increased. The results indicate that the quality of groundwater for Agriculture Plain Mehran will decline in seven years.

  9. Studies of electron cyclotron resonance ion source plasma physics

    International Nuclear Information System (INIS)

    Tarvainen, O.

    2005-01-01

    This thesis consists of an introduction to the plasma physics of electron cyclotron resonance ion sources (ECRIS) and a review of the results obtained by the author and co-workers including discussion of related work by others. The thesis begins with a theoretical discussion dealing with plasma physics relevant for the production of highly charged ions in ECR ion source plasmas. This is followed by an overview of different techniques, such as gas mixing and double frequency heating, that can be used to improve the performance of this type of ion source. The experimental part of the work consists of studies related to ECRIS plasma physics. The effect of the gas mixing technique on the production efficiency of different ion beams was studied with both gaseous and solid materials. It was observed that gas mixing improves the confinement of the heavier element while the confinement of the lighter element is reduced. When the effect of gas mixing on MIVOC-plasmas was studied with several mixing gases it was observed that applying this technique can reduce the inevitable carbon contamination by a significant factor. In order to understand the different plasma processes taking place in ECRIS plasmas, a series of plasma potential and emittance measurements was carried out. An instrument, which can be used to measure the plasma potential in a single measurement without disturbing the plasma, was developed for this work. Studying the plasma potential of ECR ion sources is important not only because it helps to understand different plasma processes, but also because the information can be used as an input parameter for beam transport simulations and ion source extraction design. The experiments performed have revealed clear dependencies of the plasma potential on certain source parameters such as the amount of carbon contamination accumulated on the walls of the plasma chamber during a MIVOC-run. It was also observed that gas mixing affects not only the production efficiency

  10. GBIS (Geodetic Bayesian Inversion Software): Rapid Inversion of InSAR and GNSS Data to Estimate Surface Deformation Source Parameters and Uncertainties

    Science.gov (United States)

    Bagnardi, M.; Hooper, A. J.

    2017-12-01

    Inversions of geodetic observational data, such as Interferometric Synthetic Aperture Radar (InSAR) and Global Navigation Satellite System (GNSS) measurements, are often performed to obtain information about the source of surface displacements. Inverse problem theory has been applied to study magmatic processes, the earthquake cycle, and other phenomena that cause deformation of the Earth's interior and of its surface. Together with increasing improvements in data resolution, both spatial and temporal, new satellite missions (e.g., European Commission's Sentinel-1 satellites) are providing the unprecedented opportunity to access space-geodetic data within hours from their acquisition. To truly take advantage of these opportunities we must become able to interpret geodetic data in a rapid and robust manner. Here we present the open-source Geodetic Bayesian Inversion Software (GBIS; available for download at http://comet.nerc.ac.uk/gbis). GBIS is written in Matlab and offers a series of user-friendly and interactive pre- and post-processing tools. For example, an interactive function has been developed to estimate the characteristics of noise in InSAR data by calculating the experimental semi-variogram. The inversion software uses a Markov-chain Monte Carlo algorithm, incorporating the Metropolis-Hastings algorithm with adaptive step size, to efficiently sample the posterior probability distribution of the different source parameters. The probabilistic Bayesian approach allows the user to retrieve estimates of the optimal (best-fitting) deformation source parameters together with the associated uncertainties produced by errors in the data (and by scaling, errors in the model). The current version of GBIS (V1.0) includes fast analytical forward models for magmatic sources of different geometry (e.g., point source, finite spherical source, prolate spheroid source, penny-shaped sill-like source, and dipping-dike with uniform opening) and for dipping faults with uniform

  11. Estimation of Source and Attenuation Parameters from Ground Motion Observations for Induced Seismicity in Alberta

    Science.gov (United States)

    Novakovic, M.; Atkinson, G. M.

    2015-12-01

    We use a generalized inversion to solve for site response, regional source and attenuation parameters, in order to define a region-specific ground-motion prediction equation (GMPE) from ground motion observations in Alberta, following the method of Atkinson et al. (2015 BSSA). The database is compiled from over 200 small to moderate seismic events (M 1 to 4.2) recorded at ~50 regional stations (distances from 30 to 500 km), over the last few years; almost all of the events have been identified as being induced by oil and gas activity. We remove magnitude scaling and geometric spreading functions from observed ground motions and invert for stress parameter, regional attenuation and site amplification. Resolving these parameters allows for the derivation of a regionally-calibrated GMPE that can be used to accurately predict amplitudes across the region in real time, which is useful for ground-motion-based alerting systems and traffic light protocols. The derived GMPE has further applications for the evaluation of hazards from induced seismicity.

  12. Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbakhsh, Sina, E-mail: sinajahanbakhsh@gmail.com; Satir, Mert; Celik, Murat [Department of Mechanical Engineering, Bogazici University, Istanbul 34342 (Turkey)

    2016-02-15

    Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

  13. A Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2012-03-01

    Full Text Available Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM, this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the water phantom is different from that of different tissues. The purpose of this study is to investigate the effects of the phantom materials on the TG-43 dosimetery parameters of the Cs-137 brachytherapy source using MCNP4C Monte Carlo code. Materials and Methods In this research, the Cs-137 (Model Selectron brachytherapy source was simulated in different phantoms (bone, soft tissue, muscle, fat, and the inhomogeneous phantoms of water/bone of volume 27000 cm3 using MCNP4C Monte Carlo code. *F8 tally was used to obtain the dose in a fine cubical lattice. Then the TG-43 dosimetry parameters of the brachytherapy source were obtained in water phantom and compared with those of different phantoms. Results The percentage difference between the radial dose function g(r of bone and the g(r of water phantom, at a distance of 10 cm from the source center is 20%, while such differences are 1.7%, 1.6% and 1.1% for soft tissue, muscle, and fat, respectively. The largest difference of the dose rate constant of phantoms with those of water is 4.52% for the bone phantom, while the differences for soft tissue, muscle, and fat are 1.18%, 1.27%, and 0.18%, respectively. The 2D anisotropy function of the Cs-137 source for different tissues is identical to that of water. Conclusion The results of the simulations have shown that dose calculation in water phantom would introduce errors in the dose calculation around brachytherapy sources. Therefore, it is suggested that the correction factors of different tissues be applied after dose calculation in water phantoms, in order to

  14. Mixed Waste Management Facility (MWMF) Old Burial Ground (OBG) source control technology and inventory study

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G.P.; Rehder, T.E.; Kanzleiter, J.P.

    1996-10-02

    This report has been developed to support information needs for wastes buried in the Burial Ground Complex. Information discussed is presented in a total of four individual attachments. The general focus of this report is to collect information on estimated source inventories, leaching studies, source control technologies, and to provide information on modeling parameters and associated data deficiencies.

  15. Mixed Waste Management Facility (MWMF) Old Burial Ground (OBG) source control technology and inventory study

    International Nuclear Information System (INIS)

    Flach, G.P.; Rehder, T.E.; Kanzleiter, J.P.

    1996-01-01

    This report has been developed to support information needs for wastes buried in the Burial Ground Complex. Information discussed is presented in a total of four individual attachments. The general focus of this report is to collect information on estimated source inventories, leaching studies, source control technologies, and to provide information on modeling parameters and associated data deficiencies

  16. Dosimetric characterization of two radium sources for retrospective dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Karlsson, M. [Division of Radiological Sciences, Department of Medical and Health Sciences, Linköping University, Linköping SE 581 85 (Sweden); Lundell, M. [Department of Medical Physics and Oncology, Karolinska University Hospital and Karolinska Institute, Stockholm SE 171 76 (Sweden); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Tedgren, Å. Carlsson [Division of Radiological Sciences, Department of Medical and Health Sciences, Linköping University, Linköping SE 581 85, Sweden and Swedish Radiation Safety Authority, Stockholm SE 171 16 (Sweden)

    2015-05-15

    Purpose: During the first part of the 20th century, {sup 226}Ra was the most used radionuclide for brachytherapy. Retrospective accurate dosimetry, coupled with patient follow up, is important for advancing knowledge on long-term radiation effects. The purpose of this work was to dosimetrically characterize two {sup 226}Ra sources, commonly used in Sweden during the first half of the 20th century, for retrospective dose–effect studies. Methods: An 8 mg {sup 226}Ra tube and a 10 mg {sup 226}Ra needle, used at Radiumhemmet (Karolinska University Hospital, Stockholm, Sweden), from 1925 to the 1960s, were modeled in two independent Monte Carlo (MC) radiation transport codes: GEANT4 and MCNP5. Absorbed dose and collision kerma around the two sources were obtained, from which the TG-43 parameters were derived for the secular equilibrium state. Furthermore, results from this dosimetric formalism were compared with results from a MC simulation with a superficial mould constituted by five needles inside a glass casing, placed over a water phantom, trying to mimic a typical clinical setup. Calculated absorbed doses using the TG-43 formalism were also compared with previously reported measurements and calculations based on the Sievert integral. Finally, the dose rate at large distances from a {sup 226}Ra point-like-source placed in the center of 1 m radius water sphere was calculated with GEANT4. Results: TG-43 parameters [including g{sub L}(r), F(r, θ), Λ, and s{sub K}] have been uploaded in spreadsheets as additional material, and the fitting parameters of a mathematical curve that provides the dose rate between 10 and 60 cm from the source have been provided. Results from TG-43 formalism are consistent within the treatment volume with those of a MC simulation of a typical clinical scenario. Comparisons with reported measurements made with thermoluminescent dosimeters show differences up to 13% along the transverse axis of the radium needle. It has been estimated that

  17. Study for a 6 GeV undulator based synchrotron radiation source

    International Nuclear Information System (INIS)

    Vignola, G.; Barton, M.; Blumberg, R.; Galayda, J.; Krinsky, S.; Luccio, A.; Pellegrini, C.; van Steenbergen, A.; Wang, J.

    1985-01-01

    A partial study for a 6 GeV undulator based synchrotron radiation source for production of high brightness undulator radiation, in the A region, is presented. The basic lattice adopted for the storage ring is a hybrid FODO Chasman-Green lattice, making use of gradient in the dipoles. We discuss also the e beam current limits and the injection parameters

  18. The Source and Impact of Specific Parameters that Enhance Well-Being in Daily Life.

    Science.gov (United States)

    Stewart, William C; Reynolds, Kelly E; Jones, Lydia J; Stewart, Jeanette A; Nelson, Lindsay A

    2016-08-01

    The purpose of this study was to review four parameters (forgiveness, gratitude, hope and empathy) frequently noted when evaluating well-being. We reviewed clinical studies from 1966 to present. We included 63 articles. All four of the parameters were shown to generally improve an individual's well-being. These parameters demonstrated a positive influence within more specific societal issues including improvement in social relationships, delinquent behavior and physical health. These parameters were generally derived from training and religion. This study suggests that these parameters may improve either one of general well-being, pro-social and positive relational behavior and demonstrate positive health effects.

  19. Development and validation of an open source quantification tool for DSC-MRI studies.

    Science.gov (United States)

    Gordaliza, P M; Mateos-Pérez, J M; Montesinos, P; Guzmán-de-Villoria, J A; Desco, M; Vaquero, J J

    2015-03-01

    This work presents the development of an open source tool for the quantification of dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion studies. The development of this tool is motivated by the lack of open source tools implemented on open platforms to allow external developers to implement their own quantification methods easily and without the need of paying for a development license. This quantification tool was developed as a plugin for the ImageJ image analysis platform using the Java programming language. A modular approach was used in the implementation of the components, in such a way that the addition of new methods can be done without breaking any of the existing functionalities. For the validation process, images from seven patients with brain tumors were acquired and quantified with the presented tool and with a widely used clinical software package. The resulting perfusion parameters were then compared. Perfusion parameters and the corresponding parametric images were obtained. When no gamma-fitting is used, an excellent agreement with the tool used as a gold-standard was obtained (R(2)>0.8 and values are within 95% CI limits in Bland-Altman plots). An open source tool that performs quantification of perfusion studies using magnetic resonance imaging has been developed and validated using a clinical software package. It works as an ImageJ plugin and the source code has been published with an open source license. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Earthquake source parameters along the Hellenic subduction zone and numerical simulations of historical tsunamis in the Eastern Mediterranean

    Science.gov (United States)

    Yolsal-Çevikbilen, Seda; Taymaz, Tuncay

    2012-04-01

    We studied source mechanism parameters and slip distributions of earthquakes with Mw ≥ 5.0 occurred during 2000-2008 along the Hellenic subduction zone by using teleseismic P- and SH-waveform inversion methods. In addition, the major and well-known earthquake-induced Eastern Mediterranean tsunamis (e.g., 365, 1222, 1303, 1481, 1494, 1822 and 1948) were numerically simulated and several hypothetical tsunami scenarios were proposed to demonstrate the characteristics of tsunami waves, propagations and effects of coastal topography. The analogy of current plate boundaries, earthquake source mechanisms, various earthquake moment tensor catalogues and several empirical self-similarity equations, valid for global or local scales, were used to assume conceivable source parameters which constitute the initial and boundary conditions in simulations. Teleseismic inversion results showed that earthquakes along the Hellenic subduction zone can be classified into three major categories: [1] focal mechanisms of the earthquakes exhibiting E-W extension within the overriding Aegean plate; [2] earthquakes related to the African-Aegean convergence; and [3] focal mechanisms of earthquakes lying within the subducting African plate. Normal faulting mechanisms with left-lateral strike slip components were observed at the eastern part of the Hellenic subduction zone, and we suggest that they were probably concerned with the overriding Aegean plate. However, earthquakes involved in the convergence between the Aegean and the Eastern Mediterranean lithospheres indicated thrust faulting mechanisms with strike slip components, and they had shallow focal depths (h < 45 km). Deeper earthquakes mainly occurred in the subducting African plate, and they presented dominantly strike slip faulting mechanisms. Slip distributions on fault planes showed both complex and simple rupture propagations with respect to the variation of source mechanism and faulting geometry. We calculated low stress drop

  1. Studying Effect of Water Quality Parameters on Coagulation Efficiency by Moringa Oleifera Seeds

    Directory of Open Access Journals (Sweden)

    Mehdi Parvini

    2015-04-01

    Full Text Available The purpose of this study is to investigate the performance and efficiency of Moringa seeds from different sources on turbidity. A protein analysis test was done for each source; then two different methods of extraction were compared to examine the coagulation activity for the Moringa's active ingredient. The results of sodium chloride (NaCI extraction in comparison to distilled water extraction of the Moringa olifera seeds showed that the salt solution extraction technique was more efficient than the distilled water for extracting the active coagulant ingredient.  The above mentioned findings were used to examine the effects of other parameters such as pH, calcium and magnesium hardness, bicarbonate-alkalinity, and salinity independently on turbidity removal with an optimum dosage of 1% NaCI extract of dry shelled Moringa seeds. The obtained results showed that the water quality parameters had no significant effect on the coagulation potential of the NaCI extract of the shelled Moringa seeds and was almost amenable to a wide range of water environment condition.

  2. SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Simiele, S; Palmer, B; DeWerd, L [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI (United States)

    2016-06-15

    Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent{sup ®} electronic brachytherapy source (Axxent{sup ®} source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent{sup ®} source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent{sup ®} source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent{sup ®} source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent{sup ®} source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft

  3. Information on Hydrologic Conceptual Models, Parameters, Uncertainty Analysis, and Data Sources for Dose Assessments at Decommissioning Sites

    International Nuclear Information System (INIS)

    Meyer, Philip D.; Gee, Glendon W.; Nicholson, Thomas J.

    1999-01-01

    This report addresses issues related to the analysis of uncertainty in dose assessments conducted as part of decommissioning analyses. The analysis is limited to the hydrologic aspects of the exposure pathway involving infiltration of water at the ground surface, leaching of contaminants, and transport of contaminants through the groundwater to a point of exposure. The basic conceptual models and mathematical implementations of three dose assessment codes are outlined along with the site-specific conditions under which the codes may provide inaccurate, potentially nonconservative results. In addition, the hydrologic parameters of the codes are identified and compared. A methodology for parameter uncertainty assessment is outlined that considers the potential data limitations and modeling needs of decommissioning analyses. This methodology uses generic parameter distributions based on national or regional databases, sensitivity analysis, probabilistic modeling, and Bayesian updating to incorporate site-specific information. Data sources for best-estimate parameter values and parameter uncertainty information are also reviewed. A follow-on report will illustrate the uncertainty assessment methodology using decommissioning test cases

  4. Information on Hydrologic Conceptual Models, Parameters, Uncertainty Analysis, and Data Sources for Dose Assessments at Decommissioning Sites

    International Nuclear Information System (INIS)

    Meyer D, Philip; Gee W, Glendon

    2000-01-01

    This report addresses issues related to the analysis of uncertainty in dose assessments conducted as part of decommissioning analyses. The analysis is limited to the hydrologic aspects of the exposure pathway involving infiltration of water at the ground surface, leaching of contaminants, and transport of contaminants through the groundwater to a point of exposure. The basic conceptual models and mathematical implementations of three dose assessment codes are outlined along with the site-specific conditions under which the codes may provide inaccurate, potentially nonconservative results. In addition, the hydrologic parameters of the codes are identified and compared. A methodology for parameter uncertainty assessment is outlined that considers the potential data limitations and modeling needs of decommissioning analyses. This methodology uses generic parameter distributions based on national or regional databases, sensitivity analysis, probabilistic modeling, and Bayesian updating to incorporate site-specific information. Data sources for best-estimate parameter values and parameter uncertainty information are also reviewed. A follow-on report will illustrate the uncertainty assessment methodology using decommissioning test cases

  5. The role of remediation, natural alkalinity sources and physical stream parameters in stream recovery.

    Science.gov (United States)

    Kruse, Natalie A; DeRose, Lisa; Korenowsky, Rebekah; Bowman, Jennifer R; Lopez, Dina; Johnson, Kelly; Rankin, Edward

    2013-10-15

    Acid mine drainage (AMD) negatively impacts not only stream chemistry, but also aquatic biology. The ultimate goal of AMD treatment is restoration of the biological community, but that goal is rarely explicit in treatment system design. Hewett Fork in Raccoon Creek Watershed, Ohio, has been impacted by historic coal mining and has been treated with a calcium oxide doser in the headwaters of the watershed since 2004. All of the acidic inputs are isolated to a 1.5 km stretch of stream in the headwaters of the Hewett Fork watershed. The macroinvertebrate and fish communities have begun to recover and it is possible to distinguish three zones downstream of the doser: an impaired zone, a transition zone and a recovered zone. Alkalinity from both the doser and natural sources and physical stream parameters play a role in stream restoration. In Hewett Fork, natural alkaline additions downstream are higher than those from the doser. Both, alkaline additions and stream velocity drive sediment and metal deposition. Metal deposition occurs in several patterns; aluminum tends to deposit in regions of low stream velocity, while iron tends to deposit once sufficient alkalinity is added to the system downstream of mining inputs. The majority of metal deposition occurs upstream of the recovered zone. Both the physical stream parameters and natural alkalinity sources influence biological recovery in treated AMD streams and should be considered in remediation plans. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Source term and behavioural parameters for a postulated HIFAR loss-of-coolant accident

    International Nuclear Information System (INIS)

    May, F.G.

    1987-01-01

    The fraction of the fission product inventory which might be released into the atmosphere of the HIFAR reactor containment building (RCB) during a postulated loss-of-coolant accident (LOCA) has been evaluated as a function of time, for each classification of airborne radioactivity. This appraisal will be used as the source term for a computer program, which uses realistic attenuation of the fission product aerosol in a single compartment model with a defined leakrate to predict possible radioactive releases into the environment in a hypothetical bounding case reactor accident which is rather more severe in all major aspects than any single LOCA. Also given are the parameters governing the attenuation of the aerosol and vapours in the atmosphere of the RCB so that their behaviour may be accurately modelled. The source terms for several other types of accident involving the meltdown of fuel elements have also been considered but in less detail than the LOCA case. In some of the cases, the fission products are released directly to atmosphere, so there is no attenuation of the release by deposition within the RCB

  7. Kinetic Parameters during Bis-GMA and TEGDMA Monomer Polymerization by ATR-FTIR: The Influence of Photoinitiator and Light Curing Source

    Directory of Open Access Journals (Sweden)

    Aline B. Denis

    2016-01-01

    Full Text Available This study aimed to analyze the kinetic parameters of two monomers using attenuated total reflectance Fourier transform infrared (ATR-FTIR: 2,2-bis-[4-(2-hydroxy-3-methacryloxypropyl-1-oxy-phenyl] propane (Bis-GMA and triethylene glycol dimethacrylate (TEGDMA. The following were calculated to evaluate the kinetic parameters: maximum conversion rate (Rpmax, time at the maximum polymerization rate (tmax, conversion at Rpmax, and total conversion recorded at the maximum conversion point after 300 s. Camphorquinone (CQ and phenyl propanedione (PPD were used in this study as photoinitiators, whereas N,N-dimethyl-p-toluidine (DMPT amine was used as a coinitiator. LED apparatus and halogen lamp were used in turn to evaluate the effect that light source had on the monomer kinetics. The mass concentration ratio for the three resin preparations was 0.7 : 0.3 for Bis-GMA and TEGDMA: R1 (CQ + DMPT, R2 (PPD + DMPT, and R3 (PPD + CQ + DMPT. The PPD association with the CQ photoinitiator altered the polymerization kinetics compared to a resin containing only the CQ photoinitiator. The light sources exhibited no significant differences for tmax of R1 and R3. Resins containing only the PPD initiator exhibited a higher tmax than those containing only CQ. However, the Rpmax decreased for resins containing the PPD photoinitiator.

  8. Study on a negative hydrogen ion source with hot cathode arc discharge.

    Science.gov (United States)

    Lin, S H; Fang, X; Zhang, H J; Qian, C; Ma, B H; Wang, H; Li, X X; Zhang, X Z; Sun, L T; Zhang, Z M; Yuan, P; Zhao, H W

    2014-02-01

    A negative hydrogen (H(-)) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H(-) beam with ɛ N, RMS = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I(e(-))/I(H(-)) were experimentally studied. The discussion on the result, and opinions to improve the source were given.

  9. Source study of the Jan Mayen transform fault strike-slip earthquakes

    Science.gov (United States)

    Rodríguez-Pérez, Q.; Ottemöller, L.

    2014-07-01

    Seismic source parameters of oceanic transform zone earthquakes have been relatively poorly studied. Previous studies showed that this type of earthquakes has unique characteristics such as not only the relatively common occurrence of slow events with weak seismic radiation at high frequencies but also the occurrence of some events that have high apparent stress indicating strong high frequency radiation. We studied 5 strike-slip earthquakes in the Jan Mayen fracture zone with magnitudes in the range of 5.9 centroid time delay compared to other oceanic transform fault earthquakes.

  10. Incorporating Nuisance Parameters in Likelihoods for Multisource Spectra

    CERN Document Server

    Conway, J.S.

    2011-01-01

    We describe here the general mathematical approach to constructing likelihoods for fitting observed spectra in one or more dimensions with multiple sources, including the effects of systematic uncertainties represented as nuisance parameters, when the likelihood is to be maximized with respect to these parameters. We consider three types of nuisance parameters: simple multiplicative factors, source spectra "morphing" parameters, and parameters representing statistical uncertainties in the predicted source spectra.

  11. A study about ions sources for solids and gases

    International Nuclear Information System (INIS)

    Perez Z, E.

    1975-01-01

    Description of the different ways of obtaining ions and the causes which limits their production is covered among the various possible combinations of parameters involved in any source in order to obtain the maximum current of ions, the following were selected: filament current against: focusing voltage and accelerating voltage, establishing also a ions current relationship between detectors. In the first pair of parameters, the increase of the accelerating voltage produced the increase of the ionization current and similarly in the second and third pair of parameters the increase of the filament current and pression respectively produced the same effect. During the separation between the discharge camera and lens it was observed that to each variation in the extraction voltage corresponded an equal variation in the focusing voltage. Finally a relationship was established in the ions current between grating and detector in order to determine the more appropriate distance between the camera and the focusing lens. The increase of the ionization current when the accelerating voltage, the magnetic field and the gas pressure are increased is interpreted as a physical fact; the efficiency of a source is considered. (author)

  12. Parameter uncertainty in simulations of extreme precipitation and attribution studies.

    Science.gov (United States)

    Timmermans, B.; Collins, W. D.; O'Brien, T. A.; Risser, M. D.

    2017-12-01

    The attribution of extreme weather events, such as heavy rainfall, to anthropogenic influence involves the analysis of their probability in simulations of climate. The climate models used however, such as the Community Atmosphere Model (CAM), employ approximate physics that gives rise to "parameter uncertainty"—uncertainty about the most accurate or optimal values of numerical parameters within the model. In particular, approximate parameterisations for convective processes are well known to be influential in the simulation of precipitation extremes. Towards examining the impact of this source of uncertainty on attribution studies, we investigate the importance of components—through their associated tuning parameters—of parameterisations relating to deep and shallow convection, and cloud and aerosol microphysics in CAM. We hypothesise that as numerical resolution is increased the change in proportion of variance induced by perturbed parameters associated with the respective components is consistent with the decreasing applicability of the underlying hydrostatic assumptions. For example, that the relative influence of deep convection should diminish as resolution approaches that where convection can be resolved numerically ( 10 km). We quantify the relationship between the relative proportion of variance induced and numerical resolution by conducting computer experiments that examine precipitation extremes over the contiguous U.S. In order to mitigate the enormous computational burden of running ensembles of long climate simulations, we use variable-resolution CAM and employ both extreme value theory and surrogate modelling techniques ("emulators"). We discuss the implications of the relationship between parameterised convective processes and resolution both in the context of attribution studies and progression towards models that fully resolve convection.

  13. Source parameter inversion for wave energy focusing to a target inclusion embedded in a three-dimensional heterogeneous halfspace

    KAUST Repository

    Karve, Pranav M.

    2016-12-28

    We discuss a methodology for computing the optimal spatio-temporal characteristics of surface wave sources necessary for delivering wave energy to a targeted subsurface formation. The wave stimulation is applied to the target formation to enhance the mobility of particles trapped in its pore space. We formulate the associated wave propagation problem for three-dimensional, heterogeneous, semi-infinite, elastic media. We use hybrid perfectly matched layers at the truncation boundaries of the computational domain to mimic the semi-infiniteness of the physical domain of interest. To recover the source parameters, we define an inverse source problem using the mathematical framework of constrained optimization and resolve it by employing a reduced-space approach. We report the results of our numerical experiments attesting to the methodology\\'s ability to specify the spatio-temporal description of sources that maximize wave energy delivery. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Evaluation of nitrogen sources (15 N) on three wheat varieties in an andisol and an ultisol in the IX Region. II: Isotopic parameters and fertilizer use efficiency

    International Nuclear Information System (INIS)

    Pino N, Ines; Buneder B, Mirta; Peyrelongue C, Amelia

    1996-01-01

    A field study was carried out in order to evaluate different N fertilizers sources in three wheat varieties considering an Andisol and an Ultisol soils, in the IX Region of the country. The dilution isotopic techniques was used, with AS, 10% at rates of 20 kg ha -1 of N. The isotopic parameters such as N in the plant derived from the nitrogen sources, the N in the plant derived from the soil, the fertilizer use efficiencies and the agronomic evaluation between them were determined. The Nddfu (%) was associated to the varieties and to the soils. In the Ultisol, Dalcahue variety had a better behaviour with SS and, in the Andisol, Laurel variety showed an special affinity with U. In three varieties, the higher % of N derived from the sources it was in the grain, showing Dalcahue variety a better translocation.The fertilizer use efficiency (FUE) and the physiological efficiency, determined according the isotopic parameters, were higher than the values determined according the conventional methodology. (author)

  15. Evaluation of nitrogen sources (15 N) on three wheat varieties in an andisol and an ultisol, in the IX region. 2. Isotopic parameters and fertilizer use efficiency

    International Nuclear Information System (INIS)

    Pino N, Ines; Peyrelongue C, A.; Buneder B, Mirta

    1997-01-01

    Full text: A field study was carried out in order to evaluate different N fertilizers sources un three wheat varieties, considering an Andisol and Ultisol soils, in the IX Region of the country. The dilution isotopic techniques was used, with As, 10% at rates of 20 kg ha -1 of N. The isotopic parameters such as N in the plant derived from the nitrogen sources, the N in the plant derived from the soil, the fertilizer use efficiencies and the agronomic evaluation between them were determined. The Nddfu (%) was associated to the varieties and to the soils. In the Ultisol, Dalcahue variety had a better behaviour with SS and, in the Andisol, Laurel variety showed an special affinity with U. In the three varieties, the higher % of N derived from the sources it was in the grain, showing Dalcahue variety a better translocation. The fertilizer use efficiency (FUE) and the physiological efficiency, determined according the isotopic parameters, were higher than the values determined according the conventional methodology

  16. Pion source parameters in heavy ion collisions

    International Nuclear Information System (INIS)

    Crowe, K.M.; Bistirlich, J.A.; Bossingham, R.R.

    1984-12-01

    Following the early work of Goldhaber, Lee, and Pais, many experiments have used the momentum correlations between identical bosons to determine the space-time extent of the pion source for various reactions between elementary hadrons. This technique, known as intensity interferometry, has recently been applied to nuclear collisions at both intermediate and very high energies. Here we report on measurements of the radius and lifetime of the pion source in the reactions 1.8 A GeV 40 Ar + KCl → 2π/sup +-/ + X, 1.8 A GeV 20 Na + NaF → 2π - + X, and 1.71 A GeV 56 Fe + Fe → 2π - + X. 11 references

  17. Ground Motion Prediction for Great Interplate Earthquakes in Kanto Basin Considering Variation of Source Parameters

    Science.gov (United States)

    Sekiguchi, H.; Yoshimi, M.; Horikawa, H.

    2011-12-01

    Broadband ground motions are estimated in the Kanto sedimentary basin which holds Tokyo metropolitan area inside for anticipated great interplate earthquakes along surrounding plate boundaries. Possible scenarios of great earthquakes along Sagami trough are modeled combining characteristic properties of the source area and adequate variation in source parameters in order to evaluate possible ground motion variation due to next Kanto earthquake. South to the rupture area of the 2011 Tohoku earthquake along the Japan trench, we consider possible M8 earthquake. The ground motions are computed with a four-step hybrid technique. We first calculate low-frequency ground motions at the engineering basement. We then calculate higher-frequency ground motions at the same position, and combine the lower- and higher-frequency motions using a matched filter. We finally calculate ground motions at the surface by computing the response of the alluvium-diluvium layers to the combined motions at the engineering basement.

  18. Optimization of operating parameters of ground source heat pump system for space heating and cooling by Taguchi method and utility concept

    International Nuclear Information System (INIS)

    Sivasakthivel, T.; Murugesan, K.; Thomas, H.R.

    2014-01-01

    Highlights: • Ground Source Heat Pump (GSHP) technology is suitable for both heating and cooling. • Important parameters that affect the GSHP performance has been listed. • Parameters of GSHP system has been optimized for heating and cooling mode. • Taguchi technique and utility concept are developed for GSHP optimization. - Abstract: Use of ground source energy for space heating applications through Ground Source Heat pump (GSHP) has been established as an efficient thermodynamic process. The electricity input to the GSHP can be reduced by increasing the COP of the system. However, the COP of a GSHP system will be different for heating and cooling mode operations. Hence in order to reduce the electricity input to the GSHP, an optimum value of COP has to be determined when GSHP is operated in both heating and cooling modes. In the present research, a methodology is proposed to optimize the operating parameters of a GSHP system which will operate on both heating and cooling modes. Condenser inlet temperature, condenser outlet temperature, dryness fraction at evaporator inlet and evaporator outlet temperature are considered as the influencing parameters of the heat pump. Optimization of these parameters for only heating or only cooling mode operation is achieved by employing Taguchi method for three level variations of the above parameters using an L 9 (3 4 ) orthogonal array. Higher the better concept has been used to get a higher COP. A computer program in FORTAN has been developed to carry out the computations and the results have been analyzed for the optimum conditions using Signal-to-Noise (SN) ratio and Analysis Of Variance (ANOVA) method. Based on this analysis, the maximum COP for only heating and only cooling operation are obtained as 4.25 and 3.32 respectively. By making use of the utility concept both the higher values of COP obtained for heating and cooling modes are optimized to get a single optimum COP for heating and cooling modes. A single

  19. Internal positron source production with a cyclotron and vacancy study in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Kawasuso, Atsuo; Masuno, Shin-ichi; Okada, Sohei [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Hasegawa, Masayuki; Suezawa, Masashi

    1997-03-01

    In order to detect thermal vacancies in Si, in situ positron annihilation measurement has been performed using an internal source method. An increase (decrease) in S-parameter (W-parameter) was observed above 1200degC. It was explained in terms of the formation of thermal vacancies. (author)

  20. Investigation of the Effects of Tissue Inhomogeneities on the Dosimetric Parameters of a Cs-137 Brachytherapy Source using the MCNP4C Code

    Directory of Open Access Journals (Sweden)

    Mehdi Zehtabian

    2010-09-01

    Full Text Available Introduction: Brachytherapy is the use of small encapsulated radioactive sources in close vicinity of tumors. Various methods are used to obtain the dose distribution around brachytherapy sources. TG-43 is a dosimetry protocol proposed by the AAPM for determining dose distributions around brachytherapy sources. The goal of this study is to update this protocol for presence of bone and air inhomogenities.  Material and Methods: To update the dose rate constant parameter of the TG-43 formalism, the MCNP4C simulations were performed in phantoms composed of water-bone and water-air combinations. The values of dose at different distances from the source in both homogeneous and inhomogeneous phantoms were estimated in spherical tally cells of 0.5 mm radius using the F6 tally. Results: The percentages of dose reductions in presence of air and bone inhomogenities for the Cs-137 source were found to be 4% and 10%, respectively. Therefore, the updated dose rate constant (Λ will also decrease by the same percentages.   Discussion and Conclusion: It can be easily concluded that such dose variations are more noticeable when using lower energy sources such as Pd-103 or I-125.

  1. A review of the nutritional content and technological parameters of indigenous sources of meat in South America.

    Science.gov (United States)

    Saadoun, A; Cabrera, M C

    2008-11-01

    Meat yields, proximate compositions, fatty acids compositions and technological parameters are reviewed for species which might be further developed as indigenous sources of meat in South America. These include the alpaca (Lama pacos), capybara (Hydrochoerus hydrochaeris), guanaco (Lama guanicoe), llama (Lama glama), nutria (Myocastor coypus), collared peccary (Tayassu tajacu), greater rhea (Rhea americana), lesser rhea (Rhea pennata), yacare (Caiman crocodilus yacare), tegu lizard (Tupinambis merianae) and green iguana (Iguana iguana).

  2. Reconstruction of Chernobyl source parameters using gamma dose rate measurements in town Pripjat

    Directory of Open Access Journals (Sweden)

    M. M. Talerko

    2010-06-01

    Full Text Available With the help of mathematical modeling of atmospheric transport the calculations of accidental release dispersion from the Chernobyl NPP to town Pripjat during period from 26 till 29 April 1986 have been carried out. Data of gamma rate measurements which was made in 31 points of the town were used. Based on the solution of atmospheric transport inverse problem the reconstruction of Chernobyl source parameters has been made including release intensity and effective source height. The input of main dose-forming radionuclides into the exposure dose during the first 40 hours after the accident (the period of population residence in the town before the evacuation has been estimated. According to the calculations the 131I deposition density averaged over the town territory was about 5.2 × 104 kBq/m2 (on 29.04.86. Minimum and maximum 131I deposition values were 2.8 × 104 kBq/m2 (western part, distance to the unit is 4.5 km and 1.2 × 105 kBq/m2 (north-eastern part of town, 2 km from the unit accordingly. For the moment of the evacuation dated April 27, deposition values were about 90 percent of these values.

  3. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    International Nuclear Information System (INIS)

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  4. Characterizing parameters of Jatropha curcas cell cultures for microgravity studies

    Science.gov (United States)

    Vendrame, Wagner A.; Pinares, Ania

    2013-06-01

    Jatropha (Jatropha curcas) is a tropical perennial species identified as a potential biofuel crop. The oil is of excellent quality and it has been successfully tested as biodiesel and in jet fuel mixes. However, studies on breeding and genetic improvement of jatropha are limited. Space offers a unique environment for experiments aiming at the assessment of mutations and differential gene expression of crops and in vitro cultures of plants are convenient for studies of genetic variation as affected by microgravity. However, before microgravity studies can be successfully performed, pre-flight experiments are necessary to characterize plant material and validate flight hardware environmental conditions. Such preliminary studies set the ground for subsequent spaceflight experiments. The objectives of this study were to compare the in vitro growth of cultures from three explant sources (cotyledon, leaf, and stem sections) of three jatropha accessions (Brazil, India, and Tanzania) outside and inside the petriGAP, a modified group activation pack (GAP) flight hardware to fit petri dishes. In vitro jatropha cell cultures were established in petri dishes containing a modified MS medium and maintained in a plant growth chamber at 25 ± 2 °C in the dark. Parameters evaluated were surface area of the explant tissue (A), fresh weight (FW), and dry weight (DW) for a period of 12 weeks. Growth was observed for cultures from all accessions at week 12, including subsequent plantlet regeneration. For all accessions differences in A, FW and DW were observed for inside vs. outside the PetriGAPs. Growth parameters were affected by accession (genotype), explant type, and environment. The type of explant influenced the type of cell growth and subsequent plantlet regeneration capacity. However, overall cell growth showed no abnormalities. The present study demonstrated that jatropha in vitro cell cultures are suitable for growth inside PetriGAPs for a period of 12 weeks. The parameters

  5. Basic Testing of the DUCHAMP Source Finder

    Science.gov (United States)

    Westmeier, T.; Popping, A.; Serra, P.

    2012-01-01

    This paper presents and discusses the results of basic source finding tests in three dimensions (using spectroscopic data cubes) with DUCHAMP, the standard source finder for the Australian Square Kilometre Array Pathfinder. For this purpose, we generated different sets of unresolved and extended Hi model sources. These models were then fed into DUCHAMP, using a range of different parameters and methods provided by the software. The main aim of the tests was to study the performance of DUCHAMP on sources with different parameters and morphologies and assess the accuracy of DUCHAMP's source parametrisation. Overall, we find DUCHAMP to be a powerful source finder capable of reliably detecting sources down to low signal-to-noise ratios and accurately measuring their position and velocity. In the presence of noise in the data, DUCHAMP's measurements of basic source parameters, such as spectral line width and integrated flux, are affected by systematic errors. These errors are a consequence of the effect of noise on the specific algorithms used by DUCHAMP for measuring source parameters in combination with the fact that the software only takes into account pixels above a given flux threshold and hence misses part of the flux. In scientific applications of DUCHAMP these systematic errors would have to be corrected for. Alternatively, DUCHAMP could be used as a source finder only, and source parametrisation could be done in a second step using more sophisticated parametrisation algorithms.

  6. Performance analysis and experimental study of heat-source tower solution regeneration

    International Nuclear Information System (INIS)

    Liang, Caihua; Wen, Xiantai; Liu, Chengxing; Zhang, Xiaosong

    2014-01-01

    Highlights: • Theoretical analysis is performed on the characteristics of heat-source tower. • Experimental study is performed on various rules of the solution regeneration rate. • The characteristics of solution regeneration vary widely with different demands. • Results are useful for optimizing the process of solution regeneration. - Abstract: By analyzing similarities and difference between the solution regeneration of a heat-source tower and desiccant solution regeneration, this paper points out that solution regeneration of a heat-source tower has the characteristics of small demands and that a regeneration rate is susceptible to outdoor ambient environments. A theoretical analysis is performed on the characteristics of a heat-source tower solution in different outdoor environments and different regeneration modes, and an experimental study is performed on variation rules of the solution regeneration rate of a cross-flow heat-source tower under different inlet parameters and operating parameters. The experimental results show that: in the operating regeneration mode, as the air volume was increased from 123 m 3 h −1 to 550 m 3 h −1 , the system heat transfer amount increased from 0.42 kW to 0.78 kW, and the regeneration rate increased from 0.03 g s −1 to 0.19 g s −1 . Increasing the solution flow may increase the system heat transfer amount; however, the regeneration rate decreased to a certain extent. In the regeneration mode when the system is idle, as the air volume was increased from 136 m 3 h −1 to 541 m 3 h −1 , the regeneration rate increased from 0.03 g s −1 to 0.1 g s −1 . The regeneration rate almost remained unchanged around 0.07 g s −1 as the solution flow is increased. In the regeneration mode with auxiliary heat when the system is idle, increasing the air volume and increasing the solution flow required more auxiliary heat, thereby improving the solution regeneration rate. As the auxiliary heat was increased from 0.33 k

  7. Relation between sources of particulate air pollution and biological effect parameters in samples from four European cities: An exploratory study

    Energy Technology Data Exchange (ETDEWEB)

    Steerenberg, P.A.; van Amelsvoort, L.; Lovik, M.; Hetland, R.B.; Alberg, T.; Halatek, T.; Bloemen, H.J.T.; Rydzynski, K.; Swaen, G.; Schwarze, P.; Dybing, E.; Cassee, F.R. [National Institute of Public Health & Environment, Bilthoven (Netherlands). Centre for Environmental Health Research

    2006-05-15

    Given that there are widely different prevalence rates of respiratory allergies and asthma between the countries of Europe and that exposure to ambient particulate matter (PM) is substantial in urban environments throughout Europe, an EU project entitled 'Respiratory Allergy and Inflammation Due to Ambient Particles' (RAIAP) was set up. The project focused on the role of physical and chemical composition of PM on release of cytokines of cells in vitro, on respiratory inflammation in vivo, and on adjuvant potency in allergy animal models. Coarse (2.5 - 10 {mu}m) and fine (0.15 - 2.5 {mu}m) particles were collected during the spring, summer and winter in Rome ( I), Oslo (N), Lodz (PL), and Amsterdam (NL). Markers within the same model were often well correlated. Markers of inflammation in the in vitro and in vivo models also showed a high degree of correlation. In contrast, correlation between parameters in the different allergy models and between allergy and inflammation markers was generally poor. This suggests that various bioassays are needed to assess the potential hazard of PM. The present study also showed that by clustering chemical constituents of PM based on the overall response pattern in the bioassays, five distinct groups could be identified. The clusters of traffic, industrial combustion and/or incinerators, and combustion of black and brown coal/wood smoke were associated primarily with adjuvant activity for respiratory allergy, whereas clusters of crustal of material and sea spray are predominantly associated with measures for inflammation and acute toxicity. The present study has shown that biological effect of PM can be linked to one or more PM emission sources and that this linkage requires a wide range of bioassays.

  8. A summary of the sources of input parameter values for the Waste Isolation Pilot Plant final porosity surface calculations

    International Nuclear Information System (INIS)

    Butcher, B.M.

    1997-08-01

    A summary of the input parameter values used in final predictions of closure and waste densification in the Waste Isolation Pilot Plant disposal room is presented, along with supporting references. These predictions are referred to as the final porosity surface data and will be used for WIPP performance calculations supporting the Compliance Certification Application to be submitted to the U.S. Environmental Protection Agency. The report includes tables and list all of the input parameter values, references citing their source, and in some cases references to more complete descriptions of considerations leading to the selection of values

  9. A summary of the sources of input parameter values for the Waste Isolation Pilot Plant final porosity surface calculations

    Energy Technology Data Exchange (ETDEWEB)

    Butcher, B.M.

    1997-08-01

    A summary of the input parameter values used in final predictions of closure and waste densification in the Waste Isolation Pilot Plant disposal room is presented, along with supporting references. These predictions are referred to as the final porosity surface data and will be used for WIPP performance calculations supporting the Compliance Certification Application to be submitted to the U.S. Environmental Protection Agency. The report includes tables and list all of the input parameter values, references citing their source, and in some cases references to more complete descriptions of considerations leading to the selection of values.

  10. A study on regularization parameter choice in near-field acoustical holography

    DEFF Research Database (Denmark)

    Gomes, Jesper; Hansen, Per Christian

    2008-01-01

    a regularization parameter. These parameter choice methods (PCMs) are attractive, since they require no a priori knowledge about the noise. However, there seems to be no clear understanding of when one PCM is better than the other. This paper presents comparisons of three PCMs: GCV, L-curve and Normalized......), and the Equivalent Source Method (ESM). All combinations of the PCMs and the NAH methods are investigated using simulated measurements with different types of noise added to the input. Finally, the comparisons are carried out for a practical experiment. This aim of this work is to create a better understanding...... of which mechanisms that affect the performance of the different PCMs....

  11. Climate Change Studies over Bangalore using Multi-source Remote Sensing Data and GIS

    Science.gov (United States)

    B, S.; Gouda, K. C.; Laxmikantha, B. P.; Bhat, N.

    2014-12-01

    Urbanization is a form of metropolitan growth that is a response to often bewildering sets of economic, social, and political forces and to the physical geography of an area. Some of the causes of the sprawl include - population growth, economy, patterns of infrastructure initiatives like the construction of roads and the provision of infrastructure using public money encouraging development. The direct implication of such urban sprawl is the change in land use and land cover of the region. In this study the long term climate data from multiple sources like NCEP reanalysis, IMD observations and various satellite derived products from MAIRS, IMD, ERSL and TRMM are considered and analyzed using the developed algorithms for the better understanding of the variability in the climate parameters over Bangalore. These products are further mathematically analyzed to arrive at desired results by extracting land surface temperature (LST), Potential evapo-transmission (PET), Rainfall, Humidity etc. Various satellites products are derived from NASA (National Aeronautics Space Agency), Indian meteorological satellites and global satellites are helpful in massive study of urban issues at global and regional scale. Climate change analysis is well studied by using either single source data such as Temperature or Rainfall from IMD (Indian Meteorological Department) or combined data products available as in case of MAIRS (Monsoon Asia Integrated Regional Scale) program to get rainfall at regional scale. Finally all the above said parameters are normalized and analyzed with the help of various open source available software's for pre and post processing our requirements to obtain desired results. A sample of analysis i.e. the Inter annual variability of annual averaged Temperature over Bangalore is presented in figure 1, which clearly shows the rising trend of the temperature (0.06oC/year). Also the Land use and land cover (LULC) analysis over Bangalore, Day light hours from

  12. Influence of ion source configuration and its operation parameters on the target sputtering and implantation process.

    Science.gov (United States)

    Shalnov, K V; Kukhta, V R; Uemura, K; Ito, Y

    2012-06-01

    In the work, investigation of the features and operation regimes of sputter enhanced ion-plasma source are presented. The source is based on the target sputtering with the dense plasma formed in the crossed electric and magnetic fields. It allows operation with noble or reactive gases at low pressure discharge regimes, and, the resulting ion beam is the mixture of ions from the working gas and sputtering target. Any conductive material, such as metals, alloys, or compounds, can be used as the sputtering target. Effectiveness of target sputtering process with the plasma was investigated dependently on the gun geometry, plasma parameters, and the target bias voltage. With the applied accelerating voltage from 0 to 20 kV, the source can be operated in regimes of thin film deposition, ion-beam mixing, and ion implantation. Multi-component ion beam implantation was applied to α-Fe, which leads to the surface hardness increasing from 2 GPa in the initial condition up to 3.5 GPa in case of combined N(2)-C implantation. Projected range of the implanted elements is up to 20 nm with the implantation energy 20 keV that was obtained with XPS depth profiling.

  13. Numerical study of cesium effects on negative ion production in volume sources

    Energy Technology Data Exchange (ETDEWEB)

    Fukumasa, Osamu; Niitani, Eiji [Yamaguchi Univ., Ube (Japan). Faculty of Engineering

    1997-02-01

    Effects of cesium vapor injection of H{sup -} production in a tandem negative ion source are studied numerically as a function of plasma parameters. Model calculation is done by solving a set of particle balance equations in a steady-state hydrogen discharge plasmas. Here, the results which focus on gas pressure and electron temperature dependences of H{sup -} volume production are presented and discussed. With including H{sup -} surface production processes caused by both H atoms and positive hydrogen ions, enhancement of H{sup -} production and pressure dependence of H{sup -} production observed experimentally are well reproduced in the model. To enhance H{sup -} production, however, so-called electron cooling is not so effective if plasma parameters are initially optimized with the use of magnetic filter. (author)

  14. Study on Identification of Material Model Parameters from Compact Tension Test on Concrete Specimens

    Science.gov (United States)

    Hokes, Filip; Kral, Petr; Husek, Martin; Kala, Jiri

    2017-10-01

    Identification of a concrete material model parameters using optimization is based on a calculation of a difference between experimentally measured and numerically obtained data. Measure of the difference can be formulated via root mean squared error that is often used for determination of accuracy of a mathematical model in the field of meteorology or demography. The quality of the identified parameters is, however, determined not only by right choice of an objective function but also by the source experimental data. One of the possible way is to use load-displacement curves from three-point bending tests that were performed on concrete specimens. This option shows the significance of modulus of elasticity, tensile strength and specific fracture energy. Another possible option is to use experimental data from compact tension test. It is clear that the response in the second type of test is also dependent on the above mentioned material parameters. The question is whether the parameters identified within three-point bending test and within compact tension test will reach the same values. The presented article brings the numerical study of inverse identification of material model parameters from experimental data measured during compact tension tests. The article also presents utilization of the modified sensitivity analysis that calculates the sensitivity of the material model parameters for different parts of loading curve. The main goal of the article is to describe the process of inverse identification of parameters for plasticity-based material model of concrete and prepare data for future comparison with identified values of the material model parameters from different type of fracture tests.

  15. EVALUATING SOIL EROSION PARAMETER ESTIMATES FROM DIFFERENT DATA SOURCES

    Science.gov (United States)

    Topographic factors and soil loss estimates that were derived from thee data sources (STATSGO, 30-m DEM, and 3-arc second DEM) were compared. Slope magnitudes derived from the three data sources were consistently different. Slopes from the DEMs tended to provide a flattened sur...

  16. Linac Coherent Light Source (LCLS) Design Study Report

    Energy Technology Data Exchange (ETDEWEB)

    Cornacchia, Massimo

    1998-12-04

    The Stanford Linear Accelerator Center, in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. Starting in FY 1998, the first two-thirds of the SLAC linac will be used for injection into the B factory. This leaves the last one-third free for acceleration to 15 GeV. The LCLS takes advantage of this opportunity, opening the way for the next generation of synchrotron light sources with largely proven technology and cost effective methods. This proposal is consistent with the recommendations of the Report of the Basic Energy Sciences Advisory Committee (Synchrotron Radiation Light Source Working Group, October 18-19, 1997). The report recognizes that ''fourth-generation x-ray sources...will in all likelihood be based on the free electron laser concepts. If successful, this technology could yield improvements in brightness by many orders of magnitude.'' This Design Study, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac. Although this design is based on a consistent and feasible set of parameters, some components require more research and development to guarantee the performance. Given appropriate funding, this R and D phase can be completed in 2 years.

  17. Role of perisynaptic parameters in neurotransmitter homeostasis - computational study of a general synapse

    Science.gov (United States)

    Pendyam, Sandeep; Mohan, Ashwin; Kalivas, Peter W.; Nair, Satish S.

    2015-01-01

    Extracellular neurotransmitter concentrations vary over a wide range depending on the type of neurotransmitter and location in the brain. Neurotransmitter homeostasis near a synapse is achieved by a balance of several mechanisms including vesicular release from the presynapse, diffusion, uptake by transporters, non-synaptic production, and regulation of release by autoreceptors. These mechanisms are also affected by the glia surrounding the synapse. However, the role of these mechanisms in achieving neurotransmitter homeostasis is not well understood. A biophysical modeling framework was proposed to reverse engineer glial configurations and parameters related to homeostasis for synapses that support a range of neurotransmitter gradients. Model experiments reveal that synapses with extracellular neurotransmitter concentrations in the micromolar range require non-synaptic neurotransmitter sources and tight synaptic isolation by extracellular glial formations. The model was used to identify the role of perisynaptic parameters on neurotransmitter homeostasis, and to propose glial configurations that could support different levels of extracellular neurotransmitter concentrations. Ranking the parameters based on their effect on neurotransmitter homeostasis, non-synaptic sources were found to be the most important followed by transporter concentration and diffusion coefficient. PMID:22460547

  18. Qualitative Parameters of Practice during University Studies

    Science.gov (United States)

    Stasiunaitiene, Egle; Norkute, Odeta

    2011-01-01

    In this article, relevance of practice during university studies is highlighted, as well as the main stages of its organisation, qualitative parameters, as well as criteria and indicators that validate them are defined. Discussion on the idea that taking into consideration qualitative parameters of organising practice as a component of studies…

  19. Alternative definitions of kinetic parameters for accelerator driven systems

    International Nuclear Information System (INIS)

    Talamo, Alberto; Gohar, Yousry; Dulla, Sandra; Ravetto, Piero

    2012-01-01

    Highlights: ► New definition of kinetic parameters for accelerator driven systems. ► Difference between effective and average delayed neutron fraction. ► Difference between effective and average prompt neutron lifetime. ► Effect of the neutron source (Cf, D–D, D–T) on k src . ► Effect of the (n, xn) reactions and source energy-angle distribution on k src . - Abstract: This study introduces a new formulation of kinetic parameters for accelerator driven systems and it is structured into two parts. The first part is dedicated to the classic definition of the kinetic parameters and compares different calculation methodologies. The second part considers a new definition of the kinetic parameters for subcritical assemblies, with particular emphasis on the delayed neutron fraction and the prompt neutron lifetime. This new definition takes into account neutrons from the external neutron source and (n, xn) reactions, which increase the fraction of prompt neutrons. The developed theoretical framework has been applied by Monte Carlo and deterministic calculations to the YALINA Thermal subcritical assembly located in Belarus. This facility can be driven by californium, deuterium–deuterium (D–D), or deuterium–tritium (D–T) external neutron sources. For the D–T neutron source, (n, xn) reactions must be taken into account in order to produce accurate results because the average energy of D–T source neutrons is 14.1 MeV, a value which is much higher than the threshold energy of the (n, 2n) cross section of uranium isotopes.

  20. Experimental study on the impedance of linear discharge R.F. ion sources - modifications on the 'MOAK' type source; Etude experimentale de l'impedance des sources d'ions H. F. a decharge lineaire - modifications au modele de source du types 'MOAK'

    Energy Technology Data Exchange (ETDEWEB)

    Fremiot, Ch [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-15

    A method of measuring the ion R.F. source impedance is described, and the influence of the working parameters on that impedance is studied. The origin of some working anomalies is deduced with a new coupling method. The gas flow is decreased by modifying the geometry of the discharge vessel. (author) [French] On decrit une methode de mesure de l'impedance d'une source d'ions H.F. et on etudie l'influence des parametres de fonctionnement sur cette Impedance. On en deduit l'origine de quelques anomalies de fonctionnement ainsi qu'une nouvelle methode de couplage. On reduit le debit gazeux en modifiant la geometrie de l'ampoule. (auteur)

  1. The effect of wind and eruption source parameter variations on tephra fallout hazard assessment: an example from Vesuvio (Italy)

    Science.gov (United States)

    Macedonio, Giovanni; Costa, Antonio; Scollo, Simona; Neri, Augusto

    2015-04-01

    Uncertainty in the tephra fallout hazard assessment may depend on different meteorological datasets and eruptive source parameters used in the modelling. We present a statistical study to analyze this uncertainty in the case of a sub-Plinian eruption of Vesuvius of VEI = 4, column height of 18 km and total erupted mass of 5 × 1011 kg. The hazard assessment for tephra fallout is performed using the advection-diffusion model Hazmap. Firstly, we analyze statistically different meteorological datasets: i) from the daily atmospheric soundings of the stations located in Brindisi (Italy) between 1962 and 1976 and between 1996 and 2012, and in Pratica di Mare (Rome, Italy) between 1996 and 2012; ii) from numerical weather prediction models of the National Oceanic and Atmospheric Administration and of the European Centre for Medium-Range Weather Forecasts. Furthermore, we modify the total mass, the total grain-size distribution, the eruption column height, and the diffusion coefficient. Then, we quantify the impact that different datasets and model input parameters have on the probability maps. Results shows that the parameter that mostly affects the tephra fallout probability maps, keeping constant the total mass, is the particle terminal settling velocity, which is a function of the total grain-size distribution, particle density and shape. Differently, the evaluation of the hazard assessment weakly depends on the use of different meteorological datasets, column height and diffusion coefficient.

  2. Computational model of Amersham I-125 source model 6711 and Prosper Pd-103 source model MED3633 using MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Menezes, Artur F.; Reis Junior, Juraci P.; Silva, Ademir X., E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Rosa, Luiz A.R. da, E-mail: lrosa@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Facure, Alessandro [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Cardoso, Simone C., E-mail: Simone@if.ufrj.b [Universidade Federal do Rio de Janeiro (IF/UFRJ), RJ (Brazil). Inst. de Fisica. Dept. de Fisica Nuclear

    2011-07-01

    Brachytherapy is used in cancer treatment at shorter distances through the use of small encapsulated source of ionizing radiation. In such treatment, a radiation source is positioned directly into or near the target volume to be treated. In this study the Monte Carlo based MCNP code was used to model and simulate the I-125 Amersham Health source model 6711 and the Pd-103 Prospera source model MED3633 in order to obtain the dosimetric parameter dose rate constant ({Lambda}) . The sources geometries were modeled and implemented in MCNPX code. The dose rate constant is an important parameter prostate LDR brachytherapy's treatments planning. This study was based on American Association of Physicists in Medicine (AAPM) recommendations which were produced by its Task Group 43. The results obtained were 0.941 and 0.65 for the dose rate constants of I-125 and Pd-103 sources, respectively. They present good agreement with the literature values based on different Monte Carlo codes. (author)

  3. Studies on the preparation of 103Pd inner core of seed sources for brachytherapy applications

    International Nuclear Information System (INIS)

    Saha, Sujata; Manolkar, R.B.; Vimalnath, K.V.; Dash, A.; Venkatesh, Meera

    2007-01-01

    103 Pd seed sources are used widely world over for brachytherapy applications. 103 Pd available in-house was used to study its deposition on silver wire using electro-deposition and electroless deposition techniques with an aim to developing the inner core preparation of sealed radiation sources for treatment of prostate and ocular melanoma. Various parameters such as radioactive concentration of the feed solution, current density, time, temperature and pH of the solution were optimized to achieve maximum 103 Pd deposition on Ag wire. In electroless technique, the deposited amount of Pd was found to be nearly triple compared to electro-deposition in two hours time period. Both the methods gave nonleachable and well adherent sources. (author)

  4. Optimization Design and Simulation of a Multi-Source Energy Harvester Based on Solar and Radioisotope Energy Sources

    Directory of Open Access Journals (Sweden)

    Hao Li

    2016-12-01

    Full Text Available A novel multi-source energy harvester based on solar and radioisotope energy sources is designed and simulated in this work. We established the calculation formulas for the short-circuit current and open-circuit voltage, and then studied and analyzed the optimization thickness of the semiconductor, doping concentration, and junction depth with simulation of the transport process of β particles in a semiconductor material using the Monte Carlo simulation program MCNP (version 5, Radiation Safety Information Computational Center, Oak Ridge, TN, USA. In order to improve the efficiency of converting solar light energy into electric power, we adopted PC1D (version 5.9, University of New South Wales, Sydney, Australia to optimize the parameters, and selected the best parameters for converting both the radioisotope energy and solar energy into electricity. The results concluded that the best parameters for the multi-source energy harvester are as follows: Na is 1 × 1019 cm−3, Nd is 3.8 × 1016 cm−3, a PN junction depth of 0.5 μm (using the 147Pm radioisotope source, and so on. Under these parameters, the proposed harvester can achieve a conversion efficiency of 5.05% for the 147Pm radioisotope source (with the activity of 9.25 × 108 Bq and 20.8% for solar light radiation (AM1.5. Such a design and parameters are valuable for some unique micro-power fields, such as applications in space, isolated terrestrial applications, and smart dust in battlefields.

  5. Source Parameter Inversion for Recent Great Earthquakes from a Decade-long Observation of Global Gravity Fields

    Science.gov (United States)

    Han, Shin-Chan; Riva, Ricccardo; Sauber, Jeanne; Okal, Emile

    2013-01-01

    We quantify gravity changes after great earthquakes present within the 10 year long time series of monthly Gravity Recovery and Climate Experiment (GRACE) gravity fields. Using spherical harmonic normal-mode formulation, the respective source parameters of moment tensor and double-couple were estimated. For the 2004 Sumatra-Andaman earthquake, the gravity data indicate a composite moment of 1.2x10(exp 23)Nm with a dip of 10deg, in agreement with the estimate obtained at ultralong seismic periods. For the 2010 Maule earthquake, the GRACE solutions range from 2.0 to 2.7x10(exp 22)Nm for dips of 12deg-24deg and centroid depths within the lower crust. For the 2011 Tohoku-Oki earthquake, the estimated scalar moments range from 4.1 to 6.1x10(exp 22)Nm, with dips of 9deg-19deg and centroid depths within the lower crust. For the 2012 Indian Ocean strike-slip earthquakes, the gravity data delineate a composite moment of 1.9x10(exp 22)Nm regardless of the centroid depth, comparing favorably with the total moment of the main ruptures and aftershocks. The smallest event we successfully analyzed with GRACE was the 2007 Bengkulu earthquake with M(sub 0) approx. 5.0x10(exp 21)Nm. We found that the gravity data constrain the focal mechanism with the centroid only within the upper and lower crustal layers for thrust events. Deeper sources (i.e., in the upper mantle) could not reproduce the gravity observation as the larger rigidity and bulk modulus at mantle depths inhibit the interior from changing its volume, thus reducing the negative gravity component. Focal mechanisms and seismic moments obtained in this study represent the behavior of the sources on temporal and spatial scales exceeding the seismic and geodetic spectrum.

  6. Parameters estimation for X-ray sources: positions

    International Nuclear Information System (INIS)

    Avni, Y.

    1977-01-01

    It is shown that the sizes of the positional error boxes for x-ray sources can be determined by using an estimation method which we have previously formulated generally and applied in spectral analyses. It is explained how this method can be used by scanning x-ray telescopes, by rotating modulation collimators, and by HEAO-A (author)

  7. An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Feng Jinchao; Qin Chenghu; Jia Kebin; Han Dong; Liu Kai; Zhu Shouping; Yang Xin; Tian Jie [Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190 (China); College of Electronic Information and Control Engineering, Beijing University of Technology, Beijing 100124 (China); Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190 (China); Medical Image Processing Group, Institute of Automation, Chinese Academy of Sciences, P. O. Box 2728, Beijing 100190 (China) and School of Life Sciences and Technology, Xidian University, Xi' an 710071 (China)

    2011-11-15

    rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

  8. Pulsar timing residuals due to individual non-evolving gravitational wave sources

    International Nuclear Information System (INIS)

    Tong Ming-Lei; Zhao Cheng-Shi; Yan Bao-Rong; Yang Ting-Gao; Gao Yu-Ping

    2014-01-01

    The pulsar timing residuals induced by gravitational waves from non-evolving single binary sources are affected by many parameters related to the relative positions of the pulsar and the gravitational wave sources. We will analyze the various effects due to different parameters. The standard deviations of the timing residuals will be calculated with a variable parameter fixing a set of other parameters. The orbits of the binary sources will be generally assumed to be elliptical. The influences of different eccentricities on the pulsar timing residuals will also be studied in detail. We find that the effects of the related parameters are quite different, and some of them display certain regularities

  9. Experimental study and simulation of the extraction conditions of a multicharged ion beam from an electron cyclotron resonance source

    International Nuclear Information System (INIS)

    Mandin, J.

    1996-01-01

    This thesis concerns the beam extraction studies of ECR Ion Sources for the SPIRAL project at GANIL (France). The optical properties (i.e. the emittances) of the radioactive ion beam production source is a crucial point in this project. We performed emittance measurements with a very high transport efficiency and developed a computer code for simulating the extraction and transport conditions. This simulation takes into account all the parameters acting on the extraction process: the characteristics of the ions and electrons emitted by the plasma, their space and energy distributions, the space charge, the magnetic filed of the source and the accelerating electric field. We explained the evolution of the emittances for two different types of ECR Ion Source. The simulation-experiment comparison showed us that the magnetic field and the intrinsic energy of the ions seem to be the most important parameters for explaining the overall emittance behaviour of the ECRIS. We precise their values and comment them. (author)

  10. Determining the parameters of Weibull function to estimate the wind power potential in conditions of limited source meteorological data

    Science.gov (United States)

    Fetisova, Yu. A.; Ermolenko, B. V.; Ermolenko, G. V.; Kiseleva, S. V.

    2017-04-01

    We studied the information basis for the assessment of wind power potential on the territory of Russia. We described the methodology to determine the parameters of the Weibull function, which reflects the density of distribution of probabilities of wind flow speeds at a defined basic height above the surface of the earth using the available data on the average speed at this height and its repetition by gradations. The application of the least square method for determining these parameters, unlike the use of graphical methods, allows performing a statistical assessment of the results of approximation of empirical histograms by the Weibull formula. On the basis of the computer-aided analysis of the statistical data, it was shown that, at a fixed point where the wind speed changes at different heights, the range of parameter variation of the Weibull distribution curve is relatively small, the sensitivity of the function to parameter changes is quite low, and the influence of changes on the shape of speed distribution curves is negligible. Taking this into consideration, we proposed and mathematically verified the methodology of determining the speed parameters of the Weibull function at other heights using the parameter computations for this function at a basic height, which is known or defined by the average speed of wind flow, or the roughness coefficient of the geological substrate. We gave examples of practical application of the suggested methodology in the development of the Atlas of Renewable Energy Resources in Russia in conditions of deficiency of source meteorological data. The proposed methodology, to some extent, may solve the problem related to the lack of information on the vertical profile of repeatability of the wind flow speeds in the presence of a wide assortment of wind turbines with different ranges of wind-wheel axis heights and various performance characteristics in the global market; as a result, this methodology can become a powerful tool for

  11. A radio and optical study of Molonglo radio sources

    Science.gov (United States)

    Ishwara-Chandra, C. H.; Saikia, D. J.; McCarthy, P. J.; van Breugel, W. J. M.

    2001-05-01

    We present multi-wavelength radio observations with the Very Large Array, and narrow- and broad-band optical observations with the 2.5-m telescope at the Las Campanas Observatory, of a well-defined sample of high-luminosity Fanaroff-Riley class II radio galaxies and quasars, selected from the Molonglo Reference Catalogue 1-Jy sample. These observations were carried out as part of a programme to investigate the effects of orientation and environment on some of the observed properties of these sources. We examine the dependence of the Liu-Pooley relationship, which shows that radio lobes with flatter radio spectra are less depolarized, on size, identification and redshift, and show that it is significantly stronger for smaller sources, with the strength of the relationship being similar for both radio galaxies and quasars. In addition to Doppler effects, there appear to be intrinsic differences between the lobes on opposite sides. We discuss the asymmetry in brightness and location of the hotspots, and present estimates of the ages and velocities from matched-resolution observations in the L and C bands. Narrow- and broad-band optical images of some of these sources were made to study their environments and correlate with the symmetry parameters. An extended emission-line region is seen in a quasar, and in four of the objects possible companion galaxies are seen close to the radio axis.

  12. Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.

    Science.gov (United States)

    Chansangpetch, Sunee; Nguyen, Anwell; Mora, Marta; Badr, Mai; He, Mingguang; Porco, Travis C; Lin, Shan C

    2018-03-01

    To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771-0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95-3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04-3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12-1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (-0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably.

  13. Feeding at a high pitch: Source parameters of narrow band,high-frequency clicks from echolocating off-shore hourglassdolphins and coastal Hector's dolphins

    DEFF Research Database (Denmark)

    Kyhn, Line Anker; Tougaard, Jakob; Jensen, Frants Havmand

    2009-01-01

    Toothed whales depend on echolocation for orientation and prey localization, and source parameters of echolocation clicks from free-ranging animals therefore convey valuable information about the acoustic physiology and behavioral ecology of the recorded species. Recordings of wild hourglass (Lag...

  14. Parâmetros sanguíneos de vacas leiteiras suplementadas com diferentes fontes de gordura Blood parameters of dairy cows supplemented with different fat sources

    Directory of Open Access Journals (Sweden)

    José Esler de Freitas Júnior

    2010-04-01

    Full Text Available O objetivo deste trabalho foi avaliar a utilização de diferentes fontes de gordura nas rações de vacas em lactação e seus efeitos sobre o consumo de matéria seca e as concentrações dos parâmetros sangüíneos. Foram utilizadas 12 vacas da raça Holandês, agrupadas em três quadrados latinos balanceados 4x4 e alimentadas com as seguintes rações: 1 controle; 2 óleo de soja refinado; 3 grão de soja in natura; e 4 sais de cálcio de ácidos graxos (Megalac-E. As concentrações de colesterol total, colesterol, lipoproteína de baixa densidade (LDL e colesterol de alta densidade (HDL foram maiores (PThis study was carried out to evaluate the use of different fat sources in dairy cows rations and its effects on dry matter intake, milk yield and composition, and blood parameter. Twelve Holstein cows were allocated in three balanced latin square 4x4, and fed with the following rations: 1 Control, with 2.5%; 2 Refined soybean oil; 3 Whole soybean; and 4, Calcium salts of fatty acids (Megalac-E. The concentrations of total cholesterol and lipoprotein low density (LDL were higher (P<0.05 for cows that received rations with fat sources, which also causes increased (P<0.05 e concentration of high density lipoprotein (HDL. The concentrations of urea and blood urea nitrogen were similar among the rations, except for the diet containing calcium salts of fatty acids, which showed lower (P<0.05. The dry matter intake was lower (P<0.05 in cows that received calcium salts in the rations. The animals that received a diet containing whole soybeans as a source of fat had lower (P<0.05 yield milk when compared to other rations used. The use of fat sources in dairy cows rations influenced the blood parameters, especially for parameters related to lipidogram.

  15. PRELIMINARY STUDY OF HEMATOLOGICAL PARAMETERS IN HERZEGOVINIAN DONKEY

    Directory of Open Access Journals (Sweden)

    Dunja Rukavina

    2016-02-01

    Full Text Available Herzegovinian donkey is a very important animal resource of Bosnia and Herzegovina. There have been no works attempted at determining the normal values of hematological parameters of Herzegovinian donkey. For this reason, the objective of the present study was to investigate some hematological parameters in Herzegovinian donkey. The research was performed on 30 apparently healthy donkeys (18 female and 12 male of ages from 1 to 20 years. Blood samples (3 ml were obtained by jugular vein puncture (vena jugularis externa in vacuum tubes with EDTA. The mean value of hematocrit was 29.19 %, hemoglobin concentration 10.6 g/dl, mean corpuscular hemoglobin concentration 36.33 g/dl, white blood cells 9.33 x109/L, granulocytes (109/L 5.45 x109/L, granulocytes (% 59.47%, lymphocyte/monocyte (109/L 3.89 x109/L, lymphocyte/monocyte (% 40.53% and platelet cells 148.97 x109/L. Parameters were determined using an automated analyzer IDEXX QBC VET AutoRead. Data were analyzed by SPSS V 15. All hematological parameters (except platelet cells were consistent with the recommended reference ranges for donkeys, and the values found in literature so far. Platelet cells values were much lower than in the literature for the other donkey breeds and the recommended reference ranges for donkeys. The slight differences found between our results and those reported in the previous works confirm the need for further studies to investigate the reference values of hematological parameters of Herzegovinian donkey. This work is a contribution to the study of hematological parameters of Herzegovinian donkey, and we expect these data to be applied to the further studies.

  16. Experimental determination of chosen document elements parameters from raster graphics sources

    Directory of Open Access Journals (Sweden)

    Jiří Rybička

    2010-01-01

    Full Text Available Visual appearance of documents and their formal quality is considered to be as important as the content quality. Formal and typographical quality of documents can be evaluated by an automated system that processes raster images of documents. A document is described by a formal model that treats a page as an object and also as a set of elements, whereas page elements include text and graphic object. All elements are described by their parameters depending on elements’ type. For future evaluation, mainly text objects are important. This paper describes the experimental determination of chosen document elements parameters from raster images. Techniques for image processing are used, where an image is represented as a matrix of dots and parameter values are extracted. Algorithms for parameter extraction from raster images were designed and were aimed mainly at typographical parameters like indentation, alignment, font size or spacing. Algorithms were tested on a set of 100 images of paragraphs or pages and provide very good results. Extracted parameters can be directly used for typographical quality evaluation.

  17. DAQ system for low density plasma parameters measurement

    International Nuclear Information System (INIS)

    Joshi, Rashmi S.; Gupta, Suryakant B.

    2015-01-01

    In various cases where low density plasmas (number density ranges from 1E4 to 1E6 cm -3 ) exist for example, basic plasma studies or LEO space environment measurement of plasma parameters becomes very critical. Conventional tip (cylindrical) Langmuir probes often result into unstable measurements in such lower density plasma. Due to larger surface area, a spherical Langmuir probe is used to measure such lower plasma densities. Applying a sweep voltage signal to the probe and measuring current values corresponding to these voltages gives V-I characteristics of plasma which can be plotted on a digital storage oscilloscope. This plot is analyzed for calculating various plasma parameters. The aim of this paper is to measure plasma parameters using a spherical Langmuir probe and indigenously developed DAQ system. DAQ system consists of Keithley source-meter and a host system connected by a GPIB interface. An online plasma parameter diagnostic system is developed for measuring plasma properties for non-thermal plasma in vacuum. An algorithm is developed using LabVIEW platform. V-I characteristics of plasma are plotted with respect to different filament current values and different locations of Langmuir probe with reference to plasma source. V-I characteristics is also plotted for forward and reverse voltage sweep generated programmatically from the source meter. (author)

  18. Thermal-hydraulic studies of the Advanced Neutron Source cold source

    International Nuclear Information System (INIS)

    Williams, P.T.; Lucas, A.T.

    1995-08-01

    The Advanced Neutron Source (ANS), in its conceptual design phase at Oak Ridge National Laboratory, was to be a user-oriented neutron research facility producing the most intense steady-state flux of thermal and cold neutrons in the world. Among its many scientific applications, the production of cold neutrons was a significant research mission for the ANS. The cold neutrons come from two independent cold sources positioned near the reactor core. Contained by an aluminum alloy vessel, each cold source is a 410-mm-diam sphere of liquid deuterium that functions both as a neutron moderator and a cryogenic coolant. With nuclear heating of the containment vessel and internal baffling, steady-state operation requires close control of the liquid deuterium flow near the vessel's inner surface. Preliminary thermal-hydraulic analyses supporting the cold source design were performed with heat conduction simulations of the vessel walls and multidimensional computational fluid dynamics simulations of the liquid deuterium flow and heat transfer. This report presents the starting phase of a challenging program and describes the cold source conceptual design, the thermal-hydraulic feasibility studies of the containment vessel, and the future computational and experimental studies that were planned to verify the final design

  19. Techno-economic study of hydrogen production by high temperature electrolysis and coupling with different thermal energy sources

    International Nuclear Information System (INIS)

    Rivera-Tinoco, R.

    2009-03-01

    This work focuses on the techno-economic study of massive hydrogen production by the High Temperature Electrolysis (HTE) process and also deals with the possibility of producing the steam needed in the process by using different thermal energy sources. Among several sources, those retained in this study are the biomass and domestic waste incineration units, as well as two nuclear reactors (European Pressurised water Reactor - EPR and Sodium Fast Reactor - SFR). Firstly, the technical evaluation of the steam production by each of these sources was carried out. Then, the design and modelling of the equipments composing the process, specially the electrolysers (Solid Oxides Electrolysis Cells), are presented. Finally, the hydrogen production cost for each energy sources coupled with the HTE process is calculated. Moreover, several sensibility studies were performed in order to determine the process key parameter and to evaluate the influence of the unit size effect, the electric energy cost, maintenance, the cells current density, their investment cost and their lifespan on the hydrogen production cost. Our results show that the thermal energy cost is much more influent on the hydrogen production cost than the steam temperature at the outlet stream of the thermal source. It seems also that the key parameters for this process are the electric energy cost and the c ells lifespan. The first one contributes for more than 70% of the hydrogen production cost. From several cell lifespan values, it seems that a 3 year value, rather than 1 year, could lead to a hydrogen production cost reduced on 34%. However, longer lifespan values going from 5 to 10 years would only lead to a 8% reduction on the hydrogen production cost. (author)

  20. A novel low cost pulse excitation source to study trap spectroscopy of persistent luminescent materials

    Science.gov (United States)

    Chandrasekhar, Ngangbam; Singh, Nungleppam Monorajan; Gartia, R. K.

    2018-04-01

    Luminescent techniques require one or the other source of excitations which may vary from high cost X-rays, γ-rays, β-rays etc. to low cost LED. Persistent luminescent materials or Glow-in-the-Dark phosphors are the optical harvesters which store the optical energy from day light illuminating a whole night. They are so sensitive that they can be excited even with the low light of firefly. Therefore, instead of using a high cost excitation source authors have developed a low cost functioning of excitation source controlling short pulses of LED to excite persistent phosphors with the aid of ExpEYES Junior (Hardware/software framework developed by IUAC, New Delhi). Using this, the authors have excited the sample under investigation upto 10 ms. Trap spectroscopy of the pre-excited sample with LED is studied using Thermoluminescence (TL) technique. In this communication, development of the excitation source is discussed and demonstrate the its usefulness in the study of trap spectroscopy of commercially available CaS:Eu2+, Sm3+. Trapping parameters are also evaluated using Computerized Glow Curve Deconvolution (CGCD) technique.

  1. SU-E-T-212: Comparison of TG-43 Dosimetric Parameters of Low and High Energy Brachytherapy Sources Obtained by MCNP Code Versions of 4C, X and 5

    Energy Technology Data Exchange (ETDEWEB)

    Zehtabian, M; Zaker, N; Sina, S [Shiraz University, Shiraz, Fars (Iran, Islamic Republic of); Meigooni, A Soleimani [Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States)

    2015-06-15

    Purpose: Different versions of MCNP code are widely used for dosimetry purposes. The purpose of this study is to compare different versions of the MCNP codes in dosimetric evaluation of different brachytherapy sources. Methods: The TG-43 parameters such as dose rate constant, radial dose function, and anisotropy function of different brachytherapy sources, i.e. Pd-103, I-125, Ir-192, and Cs-137 were calculated in water phantom. The results obtained by three versions of Monte Carlo codes (MCNP4C, MCNPX, MCNP5) were compared for low and high energy brachytherapy sources. Then the cross section library of MCNP4C code was changed to ENDF/B-VI release 8 which is used in MCNP5 and MCNPX codes. Finally, the TG-43 parameters obtained using the MCNP4C-revised code, were compared with other codes. Results: The results of these investigations indicate that for high energy sources, the differences in TG-43 parameters between the codes are less than 1% for Ir-192 and less than 0.5% for Cs-137. However for low energy sources like I-125 and Pd-103, large discrepancies are observed in the g(r) values obtained by MCNP4C and the two other codes. The differences between g(r) values calculated using MCNP4C and MCNP5 at the distance of 6cm were found to be about 17% and 28% for I-125 and Pd-103 respectively. The results obtained with MCNP4C-revised and MCNPX were similar. However, the maximum difference between the results obtained with the MCNP5 and MCNP4C-revised codes was 2% at 6cm. Conclusion: The results indicate that using MCNP4C code for dosimetry of low energy brachytherapy sources can cause large errors in the results. Therefore it is recommended not to use this code for low energy sources, unless its cross section library is changed. Since the results obtained with MCNP4C-revised and MCNPX were similar, it is concluded that the difference between MCNP4C and MCNPX is their cross section libraries.

  2. Relation between aerosol sources and meteorological parameters for inhalable atmospheric particles in Sao Paulo City, Brazil

    Science.gov (United States)

    Andrade, Fatima; Orsini, Celso; Maenhaut, Willy

    Stacked filter units were used to collect atmospheric particles in separate coarse and fine fractions at the Sao Paulo University Campus during the winter of 1989. The samples were analysed by particle-induced X-ray emission (PIXE) and the data were subjected to an absolute principal component analysis (APCA). Five sources were identified for the fine particles: industrial emissions, which accounted for 13% of the fine mass; emissions from residual oil and diesel, explaining 41%; resuspended soil dust, with 28%; and emissions of Cu and of Mg, together with 18%. For the coarse particles, four sources were identified: soil dust, accounting for 59% of the coarse mass; industrial emissions, with 19%; oil burning, with 8%; and sea salt aerosol, with 14% of the coarse mass. A data set with various meteorological parameters was also subjected to APCA, and a correlation analysis was performed between the meteorological "absolute principal component scores" (APCS) and the APCS from the fine and coarse particle data sets. The soil dust sources for the fine and coarse aerosol were highly correlated with each other and were anticorrelated with the sea breeze component. The industrial components in the fine and coarse size fractions were also highly positively correlated. Furthermore, the industrial component was related with the northeasterly wind direction and, to a lesser extent, with the sea breeze component.

  3. A Bayesian approach for evaluation of the effect of water quality model parameter uncertainty on TMDLs: A case study of Miyun Reservoir

    International Nuclear Information System (INIS)

    Liang, Shidong; Jia, Haifeng; Xu, Changqing; Xu, Te; Melching, Charles

    2016-01-01

    Facing increasingly serious water pollution, the Chinese government is changing the environmental management strategy from solely pollutant concentration control to a Total Maximum Daily Load (TMDL) program, and water quality models are increasingly being applied to determine the allowable pollutant load in the TMDL. Despite the frequent use of models, few studies have focused on how parameter uncertainty in water quality models affect the allowable pollutant loads in the TMDL program, particularly for complicated and high-dimension water quality models. Uncertainty analysis for such models is limited by time-consuming simulation and high-dimensionality and nonlinearity in parameter spaces. In this study, an allowable pollutant load calculation platform was established using the Environmental Fluid Dynamics Code (EFDC), which is a widely applied hydrodynamic-water quality model. A Bayesian approach, i.e. the DiffeRential Evolution Adaptive Metropolis (DREAM) algorithm, which is a high-efficiency, multi-chain Markov Chain Monte Carlo (MCMC) method, was applied to assess the effects of parameter uncertainty on the water quality model simulations and its influence on the allowable pollutant load calculation in the TMDL program. Miyun Reservoir, which is the most important surface drinking water source for Beijing, suffers from eutrophication and was selected as a case study. The relations between pollutant loads and water quality indicators are obtained through a graphical method in the simulation platform. Ranges of allowable pollutant loads were obtained according to the results of parameter uncertainty analysis, i.e. Total Organic Carbon (TOC): 581.5–1030.6 t·yr"−"1; Total Phosphorus (TP): 23.3–31.0 t·yr"−"1; and Total Nitrogen (TN): 480–1918.0 t·yr"−"1. The wide ranges of allowable pollutant loads reveal the importance of parameter uncertainty analysis in a TMDL program for allowable pollutant load calculation and margin of safety (MOS

  4. Research on Relationship Between Parameters Correlation of Acoustic Emission and Rock Failure

    Directory of Open Access Journals (Sweden)

    Duan Dong

    2014-12-01

    Full Text Available Analyzes that granite AE signal parameters under uniaxial loading by that way of Pearson linear correlation, research that correlation of characterization parameters within that separate group with various characteristics, and analyzes that relationship between each parameter and destruction. This study shows that: impact, events and ringing are mainly used to describe the damage degree of rock, amplitude characteristics, time characteristics and frequency characteristics are mainly used for acoustic emission source properties, and energy characteristics can not only be used to describe the damage degree of rock, but also be used to analyze the acoustic emission source. That ringing counts are highly interrelated with energy, intensity, duration, RMS and ASL have high correlation, a high correlation is in the three parameters of the energy characteristics, and there is a higher correlation between the two parameters of the timing characteristics. The correlation between the parameters of frequency is very low, and the acoustic emission parameters can't be replaced for each other in analysis, which need separate analysis. Characteristics of ringing and energy can be a very good description of failure, but failure precursors can't be quantized. However, the amplitude, RMS, ASL, can quantify characterization of that precursor of failure, such as the effective voltage value 0.7 V as the precursor of destruction, the emergence of amplitude exceeding 95 dB as that destructive precursor. The relationship between the timing characteristics and damage is not obvious, so you can't use those parameters analysis that fracture of rocks. But those parameters can be used to describe AE source characteristics. The peak frequency, inverse frequency and the center frequency can't reflect AE source characteristics, and that average frequency and initial frequency can reflect AE source characteristics.

  5. [Age as source of variation in various parameters of 'delta sleep'].

    Science.gov (United States)

    Vergara, J M; Serrano, M; Brualla, J; Sáenz de Cabezón, A; López, J

    1997-12-01

    The clinic usefulness of a diagnostic test is in relationship to the precision with which measures the studied phenomenon. The lack of precision involve the reliability upon causing confounded results of the normal and diseased populations. Since the sleep varies in function of the age, to find sleep parameters that fit better to the changes that the aging produces in the sleep. Spectral analysis through the Fast Fourier Transformation of the ambulatory EEG of 28 healthy subjects. Maximum value of power (maximum depth) in a frequency of ended in a point of the sleep goes losing in a way specifies and systematical with the age. The variance accounted by this parameter is of the 87%, what, being tried to a phenomenon so variable as the sleep, supposes a interesting starting point to be applied to some pathologies in those which is presumed that the slow sleep (to which is attributed a paper in the cerebral restoration) is decreased.

  6. Intrabeam scattering studies at the Swiss light source

    CERN Document Server

    Antoniou, F; Aiba, M; Boege, M; Milas, N; Streun, A; Demma, T

    2012-01-01

    The target parameters of modern ultra-low emittance rings are entering into a regime where Intra-beam Scattering (IBS) becomes important and, in the case of linear collider damping rings, even a limitation for the delivered emittances. The Swiss Light Source (SLS) storage ring, as it has achieved a vertical geometrical emittance of around 1 pm at 2.4 GeV [1], and it has the ability to run at even lower energies, and the availability of emittance monitoring diagnostics, is an ideal testbed for IBS studies. Simulations using the classical IBS theories and tracking codes are undertaken in order to explore the possibilities and limitations for IBS measurements at the SLS. In this respect, comparison between the theories and codes is first discussed. The dependence of the output emittances, taking into account the effect of IBS, with respect to energy, bunch charge and zero current vertical and longitudinal emittance is also studied, in order to define the regimes where the IBS effect can be significant. First mea...

  7. Radiation studies in the antiproton source

    International Nuclear Information System (INIS)

    Church, M.

    1990-01-01

    Experiment E760 has a lead glass (Pb-G) calorimeter situated in the antiproton source tunnel in the accumulator ring at location A50. This location is exposed to radiation from several sources during antiproton stacking operations. A series of radiation studies has been performed over the last two years to determine the sources of this radiation and as a result, some shielding has been installed in the antiproton source in order to protect the lead glass from radiation damage

  8. Novel maturity parameters for mature to over-mature source rocks and oils based on the distribution of phenanthrene series compounds

    Directory of Open Access Journals (Sweden)

    Zixiang Wang

    2016-03-01

    Two additional novel and an optimized maturation parameters based on the distribution of phenanthrene series compounds are proposed and their relationships to EasyRo% (x are established: log(MPs/P = 0.19x + 0.08 (0.9% < EasyRo% < 2.1%; log(MPs/P = 0.64x − 0.86 (2.1% < EasyRo% < 3.4%; log(DMPs/TMPs = 0.71x − 0.55 (0.9% < EasyRo% < 3.4%; log(MTR = 0.84x − 0.75 (0.9% < EasyRo% < 3.4%. These significant positive correlations are strong argument for using log(MPs/P, log(DMPs/TMPs and log(MTR as maturity parameters, especially for mature to over-mature source rocks.

  9. Statistical study of interplanetary condition effect on geomagnetic storms: 2. Variations of parameters

    Science.gov (United States)

    Yermolaev, Yu. I.; Lodkina, I. G.; Nikolaeva, N. S.; Yermolaev, M. Yu.

    2011-02-01

    We investigate the behavior of mean values of the solar wind’s and interplanetary magnetic field’s (IMF) parameters and their absolute and relative variations during the magnetic storms generated by various types of the solar wind. In this paper, which is a continuation of paper [1], we, on the basis of the OMNI data archive for the period of 1976-2000, have analyzed 798 geomagnetic storms with D st ≤ -50 nT and their interplanetary sources: corotating interaction regions CIR, compression regions Sheath before the interplanetary CMEs; magnetic clouds MC; “Pistons” Ejecta, and an uncertain type of a source. For the analysis the double superposed epoch analysis method was used, in which the instants of the magnetic storm onset and the minimum of the D st index were taken as reference times. It is shown that the set of interplanetary sources of magnetic storms can be sub-divided into two basic groups according to their slowly and fast varying characteristics: (1) ICME (MC and Ejecta) and (2) CIR and Sheath. The mean values, the absolute and relative variations in MC and Ejecta for all parameters appeared to be either mean or lower than the mean value (the mean values of the electric field E y and of the B z component of IMF are higher in absolute value), while in CIR and Sheath they are higher than the mean value. High values of the relative density variation sN/ are observed in MC. At the same time, the high values for relative variations of the velocity, B z component, and IMF magnitude are observed in Sheath and CIR. No noticeable distinctions in the relationships between considered parameters for moderate and strong magnetic storms were observed.

  10. Influence of the low-frequency source parameters on the plasma characteristics in a dual frequency capacitively coupled plasma reactor: Two dimensional simulations

    Institute of Scientific and Technical Information of China (English)

    Xiang Xu; Hao Ge; Shuai Wang; Zhongling Dai; Younian Wang; Aimin Zhu

    2009-01-01

    A two-dimensional (2D) fluid model is presented to study the discharge of argon in a dual frequency capacitively coupled plasma (CCP) reactor. We are interested in the influence of low-frequency (LF) source parameters such as applied voltage amplitudes and low frequencies on the plasma characteristics. In this paper, the high frequency is set to 60 MHz with voltage 50 V. The simulations were carried out for low frequencies of 1, 2 and 6 MHz with LF voltage 100 V, and for LF voltages of 60, 90 and 120 V with low frequency 2 MHz. The results of 2D distributions of electric field and ion density, the ion flux impinging on the substrate and the ion energy on the powered electrode are shown. As the low frequency increases, two sources become from uncoupling to coupling, When two sources are uncoupling, the increase in LF has little impact on the plasma characteristics, but when two sources are coupling, the increase in LF decreases the uniformities of ion density and ion flux noticeably. It is also found that with the increase in LF voltage, the uniformities in the radial direction of ion density distribution and ion flux at the powered electrode decreases significantly, and the energy of ions bombarding on the powered electrode increases significantly.

  11. Blind Source Parameters for Performance Evaluation of Despeckling Filters

    Directory of Open Access Journals (Sweden)

    Nagashettappa Biradar

    2016-01-01

    Full Text Available The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI, and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink embedded with Stein’s unbiased risk estimation (SURE. The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  12. Blind Source Parameters for Performance Evaluation of Despeckling Filters.

    Science.gov (United States)

    Biradar, Nagashettappa; Dewal, M L; Rohit, ManojKumar; Gowre, Sanjaykumar; Gundge, Yogesh

    2016-01-01

    The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI), and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink) embedded with Stein's unbiased risk estimation (SURE). The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  13. Histomorphometric Parameters of the Growth Plate and Trabecular Bone in Wild-Type and Trefoil Factor Family 3 (Tff3)-Deficient Mice Analyzed by Free and Open-Source Image Processing Software.

    Science.gov (United States)

    Bijelić, Nikola; Belovari, Tatjana; Stolnik, Dunja; Lovrić, Ivana; Baus Lončar, Mirela

    2017-08-01

    Trefoil factor family 3 (Tff3) peptide is present during intrauterine endochondral ossification in mice, and its deficiency affects cancellous bone quality in secondary ossification centers of mouse tibiae. The aim of this study was to quantitatively analyze parameters describing the growth plate and primary ossification centers in tibiae of 1-month-old wild-type and Tff3 knock-out mice (n=5 per genotype) by using free and open-source software. Digital photographs of the growth plates and trabecular bone were processed by open-source computer programs GIMP and FIJI. Histomorphometric parameters were calculated using measurements made with FIJI. Tff3 knock-out mice had significantly smaller trabecular number and significantly larger trabecular separation. Trabecular bone volume, trabecular bone surface, and trabecular thickness showed no significant difference between the two groups. Although such histomorphological differences were found in the cancellous bone structure, no significant differences were found in the epiphyseal plate histomorphology. Tff3 peptide probably has an effect on the formation and quality of the cancellous bone in the primary ossification centers, but not through disrupting the epiphyseal plate morphology. This work emphasizes the benefits of using free and open-source programs for morphological studies in life sciences.

  14. History of water quality parameters - a study on the Sinos River/Brazil.

    Science.gov (United States)

    Konzen, G B; Figueiredo, J A S; Quevedo, D M

    2015-05-01

    Water is increasingly becoming a valuable resource, constituting one of the central themes of environmental, economic and social discussions. The Sinos River, located in southern Brazil, is the main river from the Sinos River Basin, representing a source of drinking water supply for a highly populated region. Considering its size and importance, it becomes necessary to conduct a study to follow up the water quality of this river, which is considered by some experts as one of the most polluted rivers in Brazil. As for this study, its great importance lies in the historical analysis of indicators. In this sense, we sought to develop aspects related to the management of water resources by performing a historical analysis of the Water Quality Index (WQI) of the Sinos River, using statistical methods. With regard to the methodological procedures, it should be pointed out that this study performs a time analysis of monitoring data on parameters related to a punctual measurement that is variable in time, using statistical tools. The data used refer to analyses of the water quality of the Sinos River (WQI) from the State Environmental Protection Agency Henrique Luiz Roessler (Fundação Estadual de Proteção Ambiental Henrique Luiz Roessler, FEPAM) covering the period between 2000 and 2008, as well as to a theoretical analysis focusing on the management of water resources. The study of WQI and its parameters by statistical analysis has shown to be effective, ensuring its effectiveness as a tool for the management of water resources. The descriptive analysis of the WQI and its parameters showed that the water quality of the Sinos River is concerning low, which reaffirms that it is one of the most polluted rivers in Brazil. It should be highlighted that there was an overall difficulty in obtaining data with the appropriate periodicity, as well as a long complete series, which limited the conduction of statistical studies such as the present one.

  15. Is correction necessary when clinically determining quantitative cerebral perfusion parameters from multi-slice dynamic susceptibility contrast MR studies?

    International Nuclear Information System (INIS)

    Salluzzi, M; Frayne, R; Smith, M R

    2006-01-01

    Several groups have modified the standard singular value decomposition (SVD) algorithm to produce delay-insensitive cerebral blood flow (CBF) estimates from dynamic susceptibility contrast (DSC) perfusion studies. However, new dependences of CBF estimates on bolus arrival times and slice position in multi-slice studies have been recently recognized. These conflicting findings can be reconciled by accounting for several experimental and algorithmic factors. Using simulation and clinical studies, the non-simultaneous measurement of arterial and tissue concentration curves (relative slice position) in a multi-slice study is shown to affect time-related perfusion parameters, e.g. arterial-tissue-delay measurements. However, the current clinical impact of relative slice position on amplitude-related perfusion parameters, e.g. CBF, can be expected to be small unless any of the following conditions are present individually or in combination: (a) high concentration curve signal-to-noise ratios, (b) small tissue mean transit times, (c) narrow arterial input functions or (d) low temporal resolution of the DSC image sequence. Recent improvements in magnetic resonance (MR) technology can easily be expected to lead to scenarios where these effects become increasingly important sources of inaccuracy for all perfusion parameter estimates. We show that using Fourier interpolated (high temporal resolution) residue functions reduces the systematic error of the perfusion parameters obtained from multi-slice studies

  16. Categorization of radiation sources

    International Nuclear Information System (INIS)

    Antonova, M.

    2000-01-01

    Through one-parameter (factor) analysis it is proved a hypothesis that the value of a radiation source (RS) activity of an application correlates with the category (the rank) given to it by the IAEA categorization although it is based on other parameters of the RS applications (practices like devices with radiation sources in industry, science, medicine and agriculture). The principles of the new IAEA categorization, taking into account the potential harm the sources may cause and the necessary regulatory control, are described. (author)

  17. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Simiele, S; Micka, J; Culberson, W; DeWerd, L [University of WI-Madison/ADCL, Madison, WI (United States)

    2014-06-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

  18. Computation of probabilistic hazard maps and source parameter estimation for volcanic ash transport and dispersion

    Energy Technology Data Exchange (ETDEWEB)

    Madankan, R. [Department of Mechanical and Aerospace Engineering, University at Buffalo (United States); Pouget, S. [Department of Geology, University at Buffalo (United States); Singla, P., E-mail: psingla@buffalo.edu [Department of Mechanical and Aerospace Engineering, University at Buffalo (United States); Bursik, M. [Department of Geology, University at Buffalo (United States); Dehn, J. [Geophysical Institute, University of Alaska, Fairbanks (United States); Jones, M. [Center for Computational Research, University at Buffalo (United States); Patra, A. [Department of Mechanical and Aerospace Engineering, University at Buffalo (United States); Pavolonis, M. [NOAA-NESDIS, Center for Satellite Applications and Research (United States); Pitman, E.B. [Department of Mathematics, University at Buffalo (United States); Singh, T. [Department of Mechanical and Aerospace Engineering, University at Buffalo (United States); Webley, P. [Geophysical Institute, University of Alaska, Fairbanks (United States)

    2014-08-15

    Volcanic ash advisory centers are charged with forecasting the movement of volcanic ash plumes, for aviation, health and safety preparation. Deterministic mathematical equations model the advection and dispersion of these plumes. However initial plume conditions – height, profile of particle location, volcanic vent parameters – are known only approximately at best, and other features of the governing system such as the windfield are stochastic. These uncertainties make forecasting plume motion difficult. As a result of these uncertainties, ash advisories based on a deterministic approach tend to be conservative, and many times over/under estimate the extent of a plume. This paper presents an end-to-end framework for generating a probabilistic approach to ash plume forecasting. This framework uses an ensemble of solutions, guided by Conjugate Unscented Transform (CUT) method for evaluating expectation integrals. This ensemble is used to construct a polynomial chaos expansion that can be sampled cheaply, to provide a probabilistic model forecast. The CUT method is then combined with a minimum variance condition, to provide a full posterior pdf of the uncertain source parameters, based on observed satellite imagery. The April 2010 eruption of the Eyjafjallajökull volcano in Iceland is employed as a test example. The puff advection/dispersion model is used to hindcast the motion of the ash plume through time, concentrating on the period 14–16 April 2010. Variability in the height and particle loading of that eruption is introduced through a volcano column model called bent. Output uncertainty due to the assumed uncertain input parameter probability distributions, and a probabilistic spatial-temporal estimate of ash presence are computed.

  19. NetMOD Version 2.0 Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Bion J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-08-01

    NetMOD ( Net work M onitoring for O ptimal D etection) is a Java-based software package for conducting simulation of seismic, hydroacoustic and infrasonic networks. Network simulations have long been used to study network resilience to station outages and to determine where additional stations are needed to reduce monitoring thresholds. NetMOD makes use of geophysical models to determine the source characteristics, signal attenuation along the path between the source and station, and the performance and noise properties of the station. These geophysical models are combined to simulate the relative amplitudes of signal and noise that are observed at each of the stations. From these signal-to-noise ratios (SNR), the probability of detection can be computed given a detection threshold. This document describes the parameters that are used to configure the NetMOD tool and the input and output parameters that make up the simulation definitions.

  20. Numerical Procedure to Forecast the Tsunami Parameters from a Database of Pre-Simulated Seismic Unit Sources

    Science.gov (United States)

    Jiménez, César; Carbonel, Carlos; Rojas, Joel

    2018-04-01

    We have implemented a numerical procedure to forecast the parameters of a tsunami, such as the arrival time of the front of the first wave and the maximum wave height in real and virtual tidal stations along the Peruvian coast, with this purpose a database of pre-computed synthetic tsunami waveforms (or Green functions) was obtained from numerical simulation of seismic unit sources (dimension: 50 × 50 km2) for subduction zones from southern Chile to northern Mexico. A bathymetry resolution of 30 arc-sec (approximately 927 m) was used. The resulting tsunami waveform is obtained from the superposition of synthetic waveforms corresponding to several seismic unit sources contained within the tsunami source geometry. The numerical procedure was applied to the Chilean tsunami of April 1, 2014. The results show a very good correlation for stations with wave amplitude greater than 1 m, in the case of the Arica tide station an error (from the maximum height of the observed and simulated waveform) of 3.5% was obtained, for Callao station the error was 12% and the largest error was in Chimbote with 53.5%, however, due to the low amplitude of the Chimbote wave (<1 m), the overestimated error, in this case, is not important for evacuation purposes. The aim of the present research is tsunami early warning, where speed is required rather than accuracy, so the results should be taken as preliminary.

  1. Dietary vitamin E dosage and source affects meat quality parameters in light weight lambs.

    Science.gov (United States)

    Leal, Leonel N; Beltrán, José A; Alonso, Verónica; Bello, José M; den Hartog, Leo A; Hendriks, Wouter H; Martín-Tereso, Javier

    2018-03-01

    Supra-nutritional vitamin E supplementation is a commonly used approach to delay lipid oxidation and colour deterioration in lamb and beef meat marketed under modified atmosphere packaging. However, these applications lack a precise calibration of dose for the desired effect and, in addition, limited information is available regarding the use of natural vitamin E for this purpose. Three hundred and sixty Rasa Aragonesa lambs were fed diets supplemented with all-rac-α-tocopheryl acetate (250, 500, 1000 and 2000 mg kg -1 compound feed), RRR-α-tocopheryl acetate (125, 250, 500 and 1000 mg kg -1 compound feed) and a basal diet without vitamin E supplementation for 14 days before slaughter at 25.8 ± 1.67 kg body weight. Vitamin E supplementation had no effect (P > 0.05) on average daily weight gain, feed intake and feed efficiency. Display time had larger effects on lipid oxidation, colour stability, myoglobin forms and meat discolouration parameters compared to vitamin E supplementation. However, vitamin E source and dosage significantly extended meat shelf-life as indicated by lipid oxidation, redness, hue angle, metmyoglobin formation, deoxymyoglobin formation, A 580-630 and I SO2 . The quantification of these effects demonstrated that the biological activity value of 1.36 used to distinguish both vitamin E sources is not appropriate for meat quality enhancing properties. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  2. Magnetic properties as tracers for source-to-sink dispersal of sediments: A case study in the Taiwan Strait

    Science.gov (United States)

    Horng, Chorng-Shern; Huh, Chih-An

    2011-09-01

    Different lithologies between Taiwan and southeastern China lead to diverse mineralogical composition for weathering products derived from the two shores of the Taiwan Strait. Pyrrhotite and magnetite are respectively the dominant magnetic minerals associated with fluvial sediments from western Taiwan and southeastern China. While magnetite commonly co-exists with pyrrhotite in sediments sourced from Taiwan, pyrrhotite has not been found in sediments sourced from mainland China. Associated with such a distinction are vast differences in magnetic properties, including magnetic susceptibility (χ), SIRM, HIRM and the S-ratio, which can be used to study the provenances of sediments in the Taiwan Strait and adjoining marginal seas. Based on any two of these parameters, the magnetic characteristics of much of the Taiwan Strait sediment can be explained using a two-endmember mixing model. Source-to-sink dispersal of sediments in the Taiwan Strait can then be traced from the distribution of these parameters. The results not only corroborate an earlier study based on radionuclides and particle size distribution ( Huh et al., 2011) but reveal more diagnostic details. Besides spatial distribution based on a large number (216) of surface sediments, we also analyzed temporal variation of magnetic properties in six well-dated cores collected at key sites along the sediment source-to-sink pathways. From profiles of these parameters in cores from the middle of the northern Taiwan Strait, it is calculated that sediment supply from Taiwan has increased substantially in the past five decades, which may very well be related to accelerated land use and increased frequency of intense rainfalls in Taiwan during the same period. The approach described in this work may be extended to other source-to-sink systems around the world and through time, especially the mountainous islands fringing the Pacific and Indian Oceans in southeastern Asia. As with Taiwan, these islands have high

  3. Preliminary studies of Brazilian wood using different radioisotopic sources

    International Nuclear Information System (INIS)

    Carvalho, Gilberto; Silva, Leonardo Gondim de Andrade e

    2013-01-01

    Due to availability and particular features, wood was one of the first materials used by mankind with a wide variety of applications. It can be used as raw material for paper and cellulose manufacturing; in industries such as chemical, naval, furniture, sports goods, toys, and musical instrument; in building construction and in the distribution of electric energy. Wood has been widely researched; therefore, wood researchers know that several aspects such as temperature, latitude, longitude, altitude, sunlight, soil, and rainfall index interfere with the growth of trees. This behavior explains why average physical-chemical properties are important when wood is studied. The majority of researchers consider density to be the most important wood property because of its straight relationship with the physical and mechanical properties of wood. There are three types of wood density: basic, apparent and green. The apparent density was used here at 12% of moisture content. In this study, four different types of wood were used: 'freijo', 'jequetiba', 'muiracatiara' and 'ipe'. For wood density determination by non-conventional method, Am-241, Ba-133 and Cs-137 radioisotopic sources; a NaI scintillation detector and a counter were used. The results demonstrated this technique to be quick and accurate. By considering the nuclear parameters obtained as half value layers and linear absorption coefficients, Cs-137 radioisotopic source demonstrated to be the best option to be used for inspection of the physical integrity of electric wooden poles and live trees for future works. (author)

  4. Recent negative ion source developments

    International Nuclear Information System (INIS)

    Alton, G.D.

    1978-01-01

    This report describes recent results obtained from studies associated with the development of negative ion sources which utilize sputtering in a diffuse cesium plasma as a means of ion beam generation. Data are presented which relate negative ion yield and important operational parameters such as cesium oven temperature and sputter probe voltage from each of the following sources: (1) A source based in principle according to the University of Aarhus design and (2) an axial geometry source. The important design aspects of the sources are given--along with a list of the negative ion intensities observed to date. Also a qualitative description and interpretation of the negative ion generation mechanism in sources which utilize sputtering in the presence of cesium is given

  5. Key parameters analysis of hybrid HEMP simulator

    International Nuclear Information System (INIS)

    Mao Congguang; Zhou Hui

    2009-01-01

    According to the new standards on the high-altitude electromagnetic pulse (HEMP) developed by International Electrotechnical Commission (IEC), the target parameter requirements of the key structure of the hybrid HEMP simulator are decomposed. Firstly, the influences of the different excitation sources and biconical structures to the key parameters of the radiated electric field wave shape are investigated and analyzed. Then based on the influence curves the target parameter requirements of the pulse generator are proposed. Finally the appropriate parameters of the biconical structure and the excitation sources are chosen, and the computational result of the electric field in free space is presented. The results are of great value for the design of the hybrid HEMP simulator. (authors)

  6. Source and LINAC3 studies

    CERN Document Server

    Bellodi, G

    2017-01-01

    In the framework of the LHC Ion Injector Upgrade pro-gramme (LIU), several activities have been carried out in2016 to improve the ion source and Linac3 performance,with the goal to increase the beam current routinely deliv-ered to LEIR. The extraction region of the GTS-LHC ionsource was upgraded with enlarged vacuum chamber aper-tures and the addition of an einzel lens, yielding highertransmission through the rest of the machine. Also, a seriesof experiments have been performed to study the effects ofdouble frequency mixing on the afterglow performance ofthe source after installation of a Travelling Wave Tube Am-plifier (TWTA) as secondary microwave source at variablefrequency. Measurements have been carried out at a dedi-cated oven test stand for better understanding of the ionsource performance. Finally, several MD sessions werededicated to the study and characterization of the strippingfoils, after evidence of degradation in time was discoveredin the 2015 run.

  7. Study of the 137Cs Stabilizer Source

    Directory of Open Access Journals (Sweden)

    GAO Yan;WANG Yan-ling;XU Zhi-jian;XU Liang;REN Chun-xia;TAN Xiao-ming;CUI Hong-qi

    2014-02-01

    Full Text Available The attenuation laws of the Cesium -137 γ-ray penetrating the ceramic core、stainless steel and tungsten steel were studied. The radioactivity of the 137Cs stabilizer source was determined through the surface dose rate of 137Cs stabilizer sources. In addition, the adsorption properties of the ceramic core were studied to improve the stability of the output rate, and established a production line. The application results showed that the output rate of ray source was accurate and was of a good consistency. At present, the source had been used in logging lithology, and achieved the realization of domestic product.

  8. A new software for deformation source optimization, the Bayesian Earthquake Analysis Tool (BEAT)

    Science.gov (United States)

    Vasyura-Bathke, H.; Dutta, R.; Jonsson, S.; Mai, P. M.

    2017-12-01

    Modern studies of crustal deformation and the related source estimation, including magmatic and tectonic sources, increasingly use non-linear optimization strategies to estimate geometric and/or kinematic source parameters and often consider both jointly, geodetic and seismic data. Bayesian inference is increasingly being used for estimating posterior distributions of deformation source model parameters, given measured/estimated/assumed data and model uncertainties. For instance, some studies consider uncertainties of a layered medium and propagate these into source parameter uncertainties, while others use informative priors to reduce the model parameter space. In addition, innovative sampling algorithms have been developed to efficiently explore the high-dimensional parameter spaces. Compared to earlier studies, these improvements have resulted in overall more robust source model parameter estimates that include uncertainties. However, the computational burden of these methods is high and estimation codes are rarely made available along with the published results. Even if the codes are accessible, it is usually challenging to assemble them into a single optimization framework as they are typically coded in different programing languages. Therefore, further progress and future applications of these methods/codes are hampered, while reproducibility and validation of results has become essentially impossible. In the spirit of providing open-access and modular codes to facilitate progress and reproducible research in deformation source estimations, we undertook the effort of developing BEAT, a python package that comprises all the above-mentioned features in one single programing environment. The package builds on the pyrocko seismological toolbox (www.pyrocko.org), and uses the pymc3 module for Bayesian statistical model fitting. BEAT is an open-source package (https://github.com/hvasbath/beat), and we encourage and solicit contributions to the project. Here, we

  9. Profiles of plasma parameters and density of negative hydrogen ions by laser detachment measurements in RF-driven ion sources; Profile der Plasmaparameter und Dichte negativer Wasserstoffionen mittels Laserdetachmentmessungen in HF-angeregten Ionenquellen

    Energy Technology Data Exchange (ETDEWEB)

    Christ-Koch, Sina

    2007-12-20

    This work shows the application of the Laserdetachment method for spatially resolved measurements of negative Hydrogen/Deuterium ion density. It was applied on a high power low pressure RF-driven ion source. The Laser detachment method is based on the measurement of electron currents on a positively biased Langmuir probe before and during/after a laser pulse. The density ratio of negative ions to electrons can be derived from the ratio of currents to the probe. The absolute density of negative ions can be obtained when the electron density is measured with the standard Langmuir probe setup. Measurements with the Langmuir probe additionally yield information about the floating and plasma potential, the electron temperature and the density of positive ions. The Laser detachment setup had to be adapted to the special conditions of the RF-driven source. In particular the existence of RF fields (1 MHz), high source potential (-20 kV), magnetic fields ({proportional_to} 7 mT) and caesium inside the source had to be considered. The density of negative ions could be identified in the range of n(H{sup -})=1.10{sup 17} 1/m{sup 3}, which is in the same order of magnitude as the electron density. Only the application of the Laser detachment method with the Langmuir probe measurements will yield spatially resolved plasma parameters and H- density profiles. The influence of diverse external parameters, such as pressure, RF-power, magnetic fields on the plasma parameters and their profiles were studied and explained. Hence, the measurements lead to a detailed understanding of the processes inside the source. (orig.)

  10. Industrial ion sources broadbeam gridless ion source technology

    CERN Document Server

    Zhurin, Viacheslav V

    2012-01-01

    Due to the large number of uses of ion sources in academia and industry, those who utilize these sources need up to date and coherent information to keep themselves abreast of developments and options, and to chose ideal solutions for quality and cost-effectiveness. This book, written by an author with a strong industrial background and excellent standing, is the comprehensive guide users and developers of ion sources have been waiting for. Providing a thorough refresher on the physics involved, this resource systematically covers the source types, components, and the operational parameters.

  11. A Comparative Study of Distribution System Parameter Estimation Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yannan; Williams, Tess L.; Gourisetti, Sri Nikhil Gup

    2016-07-17

    In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

  12. Reassessment of source parameters for three major earthquakes in the East African rift system from historical seismograms and bulletins

    OpenAIRE

    Ayele, A.; Kulhánek, O.

    2000-01-01

    Source parameters for three majo earthquakes in the East African rift are re-computed from historical seismograms and bulletins. The main shock and the largest foreshock of the August 25, 1906 earthquake sequence in the main Ethiopian rift are re-located on the eastern shoulder of the rift segment.The magnitude of the main shock is estimated to be 6.5 (Mw) from spectral analysis. The December 13, 1910 earthquake in the Rukwa rift (Western Tanzania) indicated a significant strike-slip componen...

  13. Statistical studies of powerful extragalactic radio sources

    Energy Technology Data Exchange (ETDEWEB)

    Macklin, J T

    1981-01-01

    This dissertation is mainly about the use of efficient statistical tests to study the properties of powerful extragalactic radio sources. Most of the analysis is based on subsets of a sample of 166 bright (3CR) sources selected at 178 MHz. The first chapter is introductory and it is followed by three on the misalignment and symmetry of double radio sources. The properties of nuclear components in extragalactic sources are discussed in the next chapter, using statistical tests which make efficient use of upper limits, often the only available information on the flux density from the nuclear component. Multifrequency observations of four 3CR sources are presented in the next chapter. The penultimate chapter is about the analysis of correlations involving more than two variables. The Spearman partial rank correlation coefficient is shown to be the most powerful test available which is based on non-parametric statistics. It is therefore used to study the dependences of the properties of sources on their size at constant redshift, and the results are interpreted in terms of source evolution. Correlations of source properties with luminosity and redshift are then examined.

  14. Laboratory stand for examination of the operational thermal parameters of polyvalent system for heating, cooling and domestic hot water supply using renewable energy sources

    International Nuclear Information System (INIS)

    Zlateva, Merima

    2014-01-01

    The report presents the structure of an universal laboratory stand for determine the operating parameters of a polyvalent system for utilization of renewable energy sources. The system is a combination of three modules using different technologies for renewable sources – solar energy, atmospheric air and biomass, incorporated in a common heat accumulator. The structural scheme permits the possibility to use the stand in different operating modes, to demonstrate the feasibility of using any one of the renewable energy sources both individually and in various combinations. The author express gratitude to the partners of the companies Robert Bosch Bulgaria Ltd, Ahi Carrier Bulgaria and Eratermtotal, with whose generous support is build the stand. Key words: Renewable energy sources (RES), Heating with RES, Biomass, Air to Water Heat pumps

  15. Effective parameters and neutrography dispersion in the RP-10 reactor: Preliminary study

    International Nuclear Information System (INIS)

    Lopez, Alcides; Ticona, Santiago

    2014-01-01

    This paper presents a breakthrough in the study of the most important effective parameters, alternative to the standards, of the neutrography acquisition system, considering an irradiation point source and an effective register distance, as well as the dispersive effect that some kind of materials can produce when free neutrons impact them. It was observed that they do not only depend on the shape and distance from the object to the photographic screen or the neutron beam divergence, but also on the constitution of these materials. Hydrogenated materials as well as micro and nano structured solids are capable to produce significant neutron scattering. The study is developed through the analysis of images obtained by neutrography using the neutron beam of the RP-10 nuclear reactor. False color applications to the intensity of the neutron flux which gives a color contrast and simulation of 3D images intensities have helped to interpret the obtained information. (authors).

  16. Research on point source simulating the γ-ray detection efficiencies of stander source

    International Nuclear Information System (INIS)

    Tian Zining; Jia Mingyan; Shen Maoquan; Yang Xiaoyan; Cheng Zhiwei

    2010-01-01

    For φ 75 mm x 25 mm sample, the full energy peak efficiencies on different heights of sample radius were obtained using the point sources, and the function parameters about the full energy peak efficiencies of point sources based on radius was fixed. The 59.54 keV γ-ray, 661.66 keV γ-ray, 1173.2 keV γ-ray, 1332.5 keV γ-ray detection efficiencies on different height of samples were obtained, based on the full energy peak efficiencies of point sources and its height, and the function parameters about the full energy peak efficiencies of surface sources based on sample height was fixed. The detection efficiency of (75 mm x 25 mm calibration source can be obtained by integrality, the detection efficiencies simulated by point sources are consistent with the results of stander source in 10%. Therefore, the calibration method of stander source can be substituted by the point source simulation method, and it tis feasible when there is no stander source.) (authors)

  17. Study of the Release Process of Open Source Software: Case Study

    OpenAIRE

    Eide, Tor Erik

    2007-01-01

    This report presents the results of a case study focusing on the release process of open source projects initiated with commercial motives. The purpose of the study is to gain an increased understanding of the release process, how a community can be attracted to the project, and how the interaction with the community evolves in commercial open source initiatives. Data has been gathered from four distinct sources to form the basis of this thesis. A thorough review of the open source literatu...

  18. Characterization of DBD plasma source for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kuchenbecker, M; Vioel, W [University of Applied Sciences and Arts, Faculty of Natural Sciences and Technology, Von-Ossietzky-Str. 99, 37085 Goettingen (Germany); Bibinov, N; Awakowicz, P [Institute for Electrical Engineering and Plasma Technology, Ruhr-Universitaet Bochum, Universitaetstr. 150, 44780 Bochum (Germany); Kaemlimg, A; Wandke, D, E-mail: m.kuchenbecker@web.d, E-mail: Nikita.Bibinov@rub.d, E-mail: awakowicz@aept-ruhr-uni-bochum.d, E-mail: vioel@hawk-hhg.d [CINOGY GmbH, Max-Naeder-Str. 15, 37114 Duderstadt (Germany)

    2009-02-21

    The dielectric barrier discharge (DBD) plasma source for biomedical application is characterized using optical emission spectroscopy, plasma-chemical simulation and voltage-current measurements. This plasma source possesses only one electrode covered by ceramic. Human body or some other object with enough high electric capacitance or connected to ground can serve as the opposite electrode. DBD consists of a number of microdischarge channels distributed in the gas gap between the electrodes and on the surface of the dielectric. To characterize the plasma conditions in the DBD source, an aluminium plate is used as an opposite electrode. Electric parameters, the diameter of microdischarge channel and plasma parameters (electron distribution function and electron density) are determined. The gas temperature is measured in the microdischarge channel and calculated in afterglow phase. The heating of the opposite electrode is studied using probe measurement. The gas and plasma parameters in the microdischarge channel are studied at varied distances between electrodes. According to an energy balance study, the input microdischarge electric energy dissipates mainly in heating of electrodes (about 90%) and partially (about 10%) in the production of chemical active species (atoms and metastable molecules).

  19. Parameter-space metric of semicoherent searches for continuous gravitational waves

    International Nuclear Information System (INIS)

    Pletsch, Holger J.

    2010-01-01

    Continuous gravitational-wave (CW) signals such as emitted by spinning neutron stars are an important target class for current detectors. However, the enormous computational demand prohibits fully coherent broadband all-sky searches for prior unknown CW sources over wide ranges of parameter space and for yearlong observation times. More efficient hierarchical ''semicoherent'' search strategies divide the data into segments much shorter than one year, which are analyzed coherently; then detection statistics from different segments are combined incoherently. To optimally perform the incoherent combination, understanding of the underlying parameter-space structure is requisite. This problem is addressed here by using new coordinates on the parameter space, which yield the first analytical parameter-space metric for the incoherent combination step. This semicoherent metric applies to broadband all-sky surveys (also embedding directed searches at fixed sky position) for isolated CW sources. Furthermore, the additional metric resolution attained through the combination of segments is studied. From the search parameters (sky position, frequency, and frequency derivatives), solely the metric resolution in the frequency derivatives is found to significantly increase with the number of segments.

  20. Study of the influence of the silica source on the synthesis of the zeolite precursor MCM-22

    International Nuclear Information System (INIS)

    Barbosa, A.S.; Santos, E.R.F. dos; Leite, R.C.N.; Rodrigues, M.G.F.

    2012-01-01

    Zeolite MCM-22 precursors were synthesized under hydrothermal conditions in systems with hexamethyleneimine HMI as bulking agent (driver). Synthesis parameter, such as sources of silica (aerosil® and quartz) was modified to investigate the effects on the morphology and crystallization in precursor MCM-22 zeolite. The products were characterized by X-Ray Diffraction (XRD), Energy Dispersive Spectroscopy (EDX) and Scanning Electron Microscopy (SEM). According to, the X-ray diffraction showed the same characteristic peaks of zeolite MCM-22. It was found that the parameter in this work of synthesis, silica source, affects the hydrothermal synthesis of zeolite MCM-22 precursor. This can be evidenced by the different morphologies found using the different sources of silica. (author)

  1. Study and analysis of drift chamber parameters

    International Nuclear Information System (INIS)

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  2. Is drinking water from 'improved sources' really safe? A case study in the Logone valley (Chad-Cameroon).

    Science.gov (United States)

    Sorlini, S; Palazzini, D; Mbawala, A; Ngassoum, M B; Collivignarelli, M C

    2013-12-01

    Within a cooperation project coordinated by the Association for Rural Cooperation in Africa and Latin America (ACRA) Foundation, water supplies were sampled across the villages of the Logone valley (Chad-Cameroon) mostly from boreholes, open wells, rivers and lakes as well as from some piped water. Microbiological analyses and sanitary inspections were carried out at each source. The microbiological quality was determined by analysis of indicators of faecal contamination, Escherichia coli, Enterococci and Salmonellae, using the membrane filtration method. Sanitary inspections were done using WHO query forms. The assessment confirmed that there are several parameters of health concern in the studied area; bacteria of faecal origins are the most significant. Furthermore, this study demonstrated that Joint Monitoring Programme (JMP) classification and E. coli measurement are not sufficient to state water safety. In fact, in the studied area, JMP defined 'improved sources' may provide unsafe water depending on their structure and sources without E. coli may have Enterococci and Salmonellae. Sanitary inspections also revealed high health risks for some boreholes. In other cases, sources with low sanitary risk and no E. coli were contaminated by Enterococci and Salmonellae. Better management and protection of the sources, hygiene improvement and domestic water treatment before consumption are possible solutions to reduce health risks in the Logone valley.

  3. Uncertainty analysis of flexible rotors considering fuzzy parameters and fuzzy-random parameters

    Directory of Open Access Journals (Sweden)

    Fabian Andres Lara-Molina

    Full Text Available Abstract The components of flexible rotors are subjected to uncertainties. The main sources of uncertainties include the variation of mechanical properties. This contribution aims at analyzing the dynamics of flexible rotors under uncertain parameters modeled as fuzzy and fuzzy random variables. The uncertainty analysis encompasses the modeling of uncertain parameters and the numerical simulation of the corresponding flexible rotor model by using an approach based on fuzzy dynamic analysis. The numerical simulation is accomplished by mapping the fuzzy parameters of the deterministic flexible rotor model. Thereby, the flexible rotor is modeled by using both the Fuzzy Finite Element Method and the Fuzzy Stochastic Finite Element Method. Numerical simulations illustrate the methodology conveyed in terms of orbits and frequency response functions subject to uncertain parameters.

  4. Radiotracer and Sealed Source Applications in Sediment Transport Studies

    International Nuclear Information System (INIS)

    2014-01-01

    The investigation of sediment transport in seas and rivers is crucial for civil engineering and littoral protection and management. Coastlines and seabeds are dynamic regions, with sediments undergoing periods of erosion, transport, sedimentation and consolidation. The main causes for erosion in beaches include storms and human actions such as the construction of seawalls, jetties and the dredging of stream mouths. Each of these human actions disrupts the natural flow of sand. Current policies and practices are accelerating the beach erosion process. However, there are viable options available to mitigate this damage and to provide for sustainable coastlines. Radioactive methods can help in investigating sediment dynamics, providing important parameters for better designing, maintaining and optimizing civil engineering structures. Radioisotopes as tracers and sealed sources have been useful and often irreplaceable tools for sediment transport studies. The training course material is based on lecture notes and practical works delivered by many experts in IAEA supported activities. Lectures and case studies were reviewed by a number of specialists in this field

  5. Tuned sources of submillimetre radiation

    International Nuclear Information System (INIS)

    Berezhnyj, V.L.

    1981-01-01

    The main present directions of development of sources of frequency coherent tuned radiation of electromagnetic waves in the submillimeter range: nonlinear mixing of different frequencies; semiconductor lasers; molecular lasers with optical pumping; relativistic electron beams in a magnetic field as submillimeter radiation sources; submillimeter radiation sources on the basis of SHF classical electrovacuum devices - are considered. The designs of generator systems and their specifications are presented. The main parameters of electromagnetic radiation of different sources, such as: power, stability, frequency, tuning range - are presented. The methods of improving sources and electromagnetic radiation parameters are proposed. The examples of possible applications of submillimeter radiation in different spheres of science and technology are given [ru

  6. Open-Source Data and the Study of Homicide.

    Science.gov (United States)

    Parkin, William S; Gruenewald, Jeff

    2015-07-20

    To date, no discussion has taken place in the social sciences as to the appropriateness of using open-source data to augment, or replace, official data sources in homicide research. The purpose of this article is to examine whether open-source data have the potential to be used as a valid and reliable data source in testing theory and studying homicide. Official and open-source homicide data were collected as a case study in a single jurisdiction over a 1-year period. The data sets were compared to determine whether open-sources could recreate the population of homicides and variable responses collected in official data. Open-source data were able to replicate the population of homicides identified in the official data. Also, for every variable measured, the open-sources captured as much, or more, of the information presented in the official data. Also, variables not available in official data, but potentially useful for testing theory, were identified in open-sources. The results of the case study show that open-source data are potentially as effective as official data in identifying individual- and situational-level characteristics, provide access to variables not found in official homicide data, and offer geographic data that can be used to link macro-level characteristics to homicide events. © The Author(s) 2015.

  7. A comparative study of noise in supercontinuum light sources for ultra-high resolution optical coherence tomography

    DEFF Research Database (Denmark)

    Maria J., Sanjuan-Ferrer,; Bravo Gonzalo, Ivan; Bondu, Magalie

    2017-01-01

    Supercontinuum (SC) light is a well-established technology, which finds applications in several domains ranging from chemistry to material science and imaging systems [1-2]. More specifically, its ultra-wide optical bandwidth and high average power make it an ideal tool for Optical Coherence...... Tomography (OCT). Over the last 5 years, numerous examples have demonstrated its high potential [3-4] in this context. However, SC light sources present pulse-to-pulse intensity variation that can limit the performance of any OCT system [5] by degrading their signal to noise ratio (SNR). To this goal, we...... have studied and compared the noise of several SC light sources and evaluated how their noise properties affect the performance of Ultra-High Resolution OCT (UHR-OCT) at 1300 nm. We have measured several SC light sources with different parameters (pulse length, energy, seed repetition rate, etc.). We...

  8. Preliminary studies of Brazilian wood using different radioisotopic sources

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Gilberto; Silva, Leonardo Gondim de Andrade e, E-mail: gcarval@ipen.br, E-mail: ftgasilva@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Due to availability and particular features, wood was one of the first materials used by mankind with a wide variety of applications. It can be used as raw material for paper and cellulose manufacturing; in industries such as chemical, naval, furniture, sports goods, toys, and musical instrument; in building construction and in the distribution of electric energy. Wood has been widely researched; therefore, wood researchers know that several aspects such as temperature, latitude, longitude, altitude, sunlight, soil, and rainfall index interfere with the growth of trees. This behavior explains why average physical-chemical properties are important when wood is studied. The majority of researchers consider density to be the most important wood property because of its straight relationship with the physical and mechanical properties of wood. There are three types of wood density: basic, apparent and green. The apparent density was used here at 12% of moisture content. In this study, four different types of wood were used: 'freijo', 'jequetiba', 'muiracatiara' and 'ipe'. For wood density determination by non-conventional method, Am-241, Ba-133 and Cs-137 radioisotopic sources; a NaI scintillation detector and a counter were used. The results demonstrated this technique to be quick and accurate. By considering the nuclear parameters obtained as half value layers and linear absorption coefficients, Cs-137 radioisotopic source demonstrated to be the best option to be used for inspection of the physical integrity of electric wooden poles and live trees for future works. (author)

  9. Studies on the Extraction Region of the Type VI RF Driven H- Ion Source

    Science.gov (United States)

    McNeely, P.; Bandyopadhyay, M.; Franzen, P.; Heinemann, B.; Hu, C.; Kraus, W.; Riedl, R.; Speth, E.; Wilhelm, R.

    2002-11-01

    IPP Garching has spent several years developing a RF driven H- ion source intended to be an alternative to the current ITER (International Thermonuclear Experimental Reactor) reference design ion source. A RF driven source offers a number of advantages to ITER in terms of reduced costs and maintenance requirements. Although the RF driven ion source has shown itself to be competitive with a standard arc filament ion source for positive ions many questions still remain on the physics behind the production of the H- ion beam extracted from the source. With the improvements that have been implemented to the BATMAN (Bavarian Test Machine for Negative Ions) facility over the last two years it is now possible to study both the extracted ion beam and the plasma in the vicinity of the extraction grid in greater detail. This paper will show the effect of changing the extraction and acceleration voltage on both the current and shape of the beam as measured on the calorimeter some 1.5 m downstream from the source. The extraction voltage required to operate in the plasma limit is 3 kV. The perveance optimum for the extraction system was determined to be 2.2 x 10-6 A/V3/2 and occurs at 2.7 kV extraction voltage. The horizontal and vertical beam half widths vary as a function of the extracted ion current and the horizontal half width is generally smaller than the vertical. The effect of reducing the co-extracted electron current via plasma grid biasing on the H- current extractable and the beam profile from the source is shown. It is possible in the case of a silver contaminated plasma to reduce the co-extracted electron current to 20% of the initial value by applying a bias of 12 V. In the case where argon is present in the plasma, biasing is observed to have minimal effect on the beam half width but in a pure hydrogen plasma the beam half width increases as the bias voltage increases. New Langmuir probe studies that have been carried out parallel to the plasma grid (in the

  10. Rural environment study for water from different sources in cluster of villages in Mehsana district of Gujarat.

    Science.gov (United States)

    Khatri, Nitasha; Tyagi, Sanjiv; Rawtani, Deepak

    2017-12-07

    Water pollution and water scarcity are major environmental issues in rural and urban areas. They lead to decline in the quality of water, especially drinking water. Proper qualitative assessment of water is thus necessary to ensure that the water consumed is potable. This study aims to analyze the physicochemical parameters in different sources of water in rural areas and assess the quality of water through a classification system based on BIS and CPCB standards. The classification method has defined water quality in six categories, viz., A, B, C, D, E, and F depending on the levels of physicochemical parameters in the water samples. The proposed classification system was applied to nine villages in Kadi Taluka, Mehsana district of Gujarat. The water samples were collected from borewells, lakes, Narmada Canal, and sewerage systems and were analyzed as per APHA and IS methods. It was observed that most of the physicochemical parameters of Narmada Canal and borewell water fell under class A, thus making them most suitable for drinking. Further, a health camp conducted at Karannagar village, Mehsana revealed no incidents of any waterborne diseases. However, there were certain incidents of kidney stones and joint pain in few villages due to high levels of TDS. Toxic metal analysis in all the water sources revealed low to undetectable concentration of toxic metals such as lead, arsenic, mercury, and cadmium in all the water sources. It is also recommended that the regular treatment of the Narmada Canal water be continued to maintain its excellent quality.

  11. The source parameters of 2013 Mw6.6 Lushan earthquake constrained with the restored local clipped seismic waveforms

    Science.gov (United States)

    Hao, J.; Zhang, J. H.; Yao, Z. X.

    2017-12-01

    We developed a method to restore the clipped seismic waveforms near epicenter using projection onto convex sets method (Zhang et al, 2016). This method was applied to rescue the local clipped waveforms of 2013 Mw 6.6 Lushan earthquake. We restored 88 out of 93 clipped waveforms of 38 broadband seismic stations of China Earthquake Networks (CEN). The epicenter distance of the nearest station to the epicenter that we can faithfully restore is only about 32 km. In order to investigate if the source parameters of earthquake could be determined exactly with the restored data, restored waveforms are utilized to get the mechanism of Lushan earthquake. We apply the generalized reflection-transmission coefficient matrix method to calculate the synthetic seismic records and simulated annealing method in inversion (Yao and Harkrider, 1983; Hao et al., 2012). We select 5 stations of CEN with the epicenter distance about 200km whose records aren't clipped and three-component velocity records are used. The result shows the strike, dip and rake angles of Lushan earthquake are 200o, 51o and 87o respectively, hereinafter "standard result". Then the clipped and restored seismic waveforms are applied respectively. The strike, dip and rake angles of clipped seismic waveforms are 184o, 53o and 72o respectively. The largest misfit of angle is 16o. In contrast, the strike, dip and rake angles of restored seismic waveforms are 198o, 51o and 87o respectively. It is very close to the "standard result". We also study the rupture history of Lushan earthquake constrained with the restored local broadband and teleseismic waves based on finite fault method (Hao et al., 2013). The result consists with that constrained with the strong motion and teleseismic waves (Hao et al., 2013), especially the location of the patch with larger slip. In real-time seismology, determining the source parameters as soon as possible is important. This method will help us to determine the mechanism of earthquake

  12. Parameter estimation method that directly compares gravitational wave observations to numerical relativity

    Science.gov (United States)

    Lange, J.; O'Shaughnessy, R.; Boyle, M.; Calderón Bustillo, J.; Campanelli, M.; Chu, T.; Clark, J. A.; Demos, N.; Fong, H.; Healy, J.; Hemberger, D. A.; Hinder, I.; Jani, K.; Khamesra, B.; Kidder, L. E.; Kumar, P.; Laguna, P.; Lousto, C. O.; Lovelace, G.; Ossokine, S.; Pfeiffer, H.; Scheel, M. A.; Shoemaker, D. M.; Szilagyi, B.; Teukolsky, S.; Zlochower, Y.

    2017-11-01

    We present and assess a Bayesian method to interpret gravitational wave signals from binary black holes. Our method directly compares gravitational wave data to numerical relativity (NR) simulations. In this study, we present a detailed investigation of the systematic and statistical parameter estimation errors of this method. This procedure bypasses approximations used in semianalytical models for compact binary coalescence. In this work, we use the full posterior parameter distribution for only generic nonprecessing binaries, drawing inferences away from the set of NR simulations used, via interpolation of a single scalar quantity (the marginalized log likelihood, ln L ) evaluated by comparing data to nonprecessing binary black hole simulations. We also compare the data to generic simulations, and discuss the effectiveness of this procedure for generic sources. We specifically assess the impact of higher order modes, repeating our interpretation with both l ≤2 as well as l ≤3 harmonic modes. Using the l ≤3 higher modes, we gain more information from the signal and can better constrain the parameters of the gravitational wave signal. We assess and quantify several sources of systematic error that our procedure could introduce, including simulation resolution and duration; most are negligible. We show through examples that our method can recover the parameters for equal mass, zero spin, GW150914-like, and unequal mass, precessing spin sources. Our study of this new parameter estimation method demonstrates that we can quantify and understand the systematic and statistical error. This method allows us to use higher order modes from numerical relativity simulations to better constrain the black hole binary parameters.

  13. Optimal portfolio selection between different kinds of Renewable energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Zakerinia, MohammadSaleh; Piltan, Mehdi; Ghaderi, Farid

    2010-09-15

    In this paper, selection of the optimal energy supply system in an industrial unit is taken into consideration. This study takes environmental, economical and social parameters into consideration in modeling along with technical factors. Several alternatives which include renewable energy sources, micro-CHP systems and conventional system has been compared by means of an integrated model of linear programming and three multi-criteria approaches (AHP, TOPSIS and ELECTRE III). New parameters like availability of sources, fuels' price volatility, besides traditional factors are considered in different scenarios. Results show with environmental preferences, renewable sources and micro-CHP are good alternatives for conventional systems.

  14. Study of excitation energy dependence of nuclear level density parameter

    International Nuclear Information System (INIS)

    Mohanto, G.; Nayak, B.K.; Saxena, A.

    2016-01-01

    In the present study, we have populated CN by fusion reaction and excitation energy of the intermediate nuclei is determined after first chance α-emission to investigate excitation energy dependence of the NLD parameter. Evaporated neutron spectra were measured following alpha evaporation for obtaining NLD parameter for the reaction 11 B + 197 Au, populating CN 208 Po. This CN after evaporating an α-particle populates intermediate nucleus 204 Pb. The 204 Pb has magic number of Z=82. Our aim is to study the excitation energy dependence of NLD parameter for closed shell nuclei

  15. Structural studies of the lipid membranes at the Siberia-2 synchrotron radiation source

    International Nuclear Information System (INIS)

    Kiselev, M. A.; Ermakova, E. V.; Ryabova, N. Yu.; Nayda, O. V.; Zabelin, A. V.; Pogorely, D. K.; Korneev, V. N.; Balagurov, A. M.

    2010-01-01

    Lipid membranes are a subject of contemporary interdisciplinary studies at the junction of biology, biophysics, pharmacology, and bionanotechnology. The results of the structural studies of several types of lipid membranes by the lamellar and lateral diffraction of X-ray synchrotron radiation are presented. The experiments were performed at the Mediana and DICSI stations of the Siberia-2 synchrotron radiation source at the Russian Research Center Kurchatov Institute. The data obtained are compared with the results of studying lipid membranes at the small-angle scattering beamlines D22 and D24 at LURE (France) and at the A2 beamline at DESY (Germany). The parameters of the DICSI station are shown to meet the basic requirements for the structural study of lipid systems, which are of fundamental and applied interest.

  16. Source parameters of the Bay of Bengal earthquake of 21 May 2014 and related seismotectonics of 85°E and 90°E ridges

    Science.gov (United States)

    Prakash, Rajesh; Prajapati, Sanjay Kumar; Srivastava, Hari Narain

    2018-01-01

    Source parameters of the Bay of Bengal earthquake of 21 May 2014 have been studied using full waveform inversion. Its source mechanism thus determined the orientation of the strike slip faulting as NW-SE/NE-SW. The occurrence of past earthquakes along the NE-SW nodal plane suggested its preference as the main fault which could result from the transmission of stresses from the Indian plate boundary. High stress drop of this earthquake (216 bar) is attributed to its location in the intraplate region, strike slip faulting and focus in the colder upper mantle. Comparison of the stress drop of deeper focus Hindukush earthquakes with that of the Bay of Bengal earthquake showed a smaller felt radius due to fractured lithosphere in the Himalayas vis-a-vis more efficient propagation of seismic waves in the peninsular region from the source region of this recent earthquake. The seismological evidence presented for the 85°E and 90°E ridges shows the predominance of strike slip faulting with thrusting on both the ridges. Integrating their source mechanism with that of the May 2014 earthquake, it could be inferred that the Bay of Bengal region (excluding Andaman Sumatra subduction zone) is characterised predominantly by strike slip faulting in the region north of latitude 20°N and strike slip with thrusting in the remaining portion.

  17. Effect of dietary protein sources on production performance, egg quality, and plasma parameters of laying hens

    Directory of Open Access Journals (Sweden)

    Xiaocui Wang

    2017-03-01

    Full Text Available Objective This study was conducted to evaluate the effects of dietary protein sources (soybean meal, SBM; low-gossypol cottonseed meal, LCSM; double-zero rapeseed meal, DRM on laying performance, egg quality, and plasma parameters of laying hens. Methods A total of 432 32-wk-old laying hens were randomly divided into 6 treatments with 6 replicates of 12 birds each. The birds were fed diets containing SBM, LCSM100, or DRM100 individually or in combination with an equal amount of crude protein (CP (LCSM50, DRM50, and LCSM50-DRM50. The experimental diets, which were isocaloric (metabolizable energy, 11.11 MJ/kg and isonitrogenous (CP, 16.5%, had similar digestible amino acid profile. The feeding trial lasted 12 weeks. Results The daily egg mass was decreased in the LCSM100 and LCSM50-DRM50 groups (p0.05 and showed increased yolk color at the end of the trial (p0.05. Conclusion Together, our results suggest that the LCSM100 or DRM100 diets may produce the adverse effects on laying performance and egg quality after feeding for 8 more weeks. The 100.0 g/kg LCSM diet or the148.7 g/kg DRM diet has no adverse effects on laying performance and egg quality.

  18. Modeling the Influence of Process Parameters and Additional Heat Sources on Residual Stresses in Laser Cladding

    Science.gov (United States)

    Brückner, F.; Lepski, D.; Beyer, E.

    2007-09-01

    In laser cladding thermal contraction of the initially liquid coating during cooling causes residual stresses and possibly cracks. Preweld or postweld heating using inductors can reduce the thermal strain difference between coating and substrate and thus reduce the resulting stress. The aim of this work is to better understand the influence of various thermometallurgical and mechanical phenomena on stress evolution and to optimize the induction-assisted laser cladding process to get crack-free coatings of hard materials at high feed rates. First, an analytical one-dimensional model is used to visualize the most important features of stress evolution for a Stellite coating on a steel substrate. For more accurate studies, laser cladding is simulated including the powder-beam interaction, the powder catchment by the melt pool, and the self-consistent calculation of temperature field and bead shape. A three-dimensional finite element model and the required equivalent heat sources are derived from the results and used for the transient thermomechanical analysis, taking into account phase transformations and the elastic-plastic material behavior with strain hardening. Results are presented for the influence of process parameters such as feed rate, heat input, and inductor size on the residual stresses at a single bead of Stellite coatings on steel.

  19. Thermal neutron source study

    International Nuclear Information System (INIS)

    Holden, T.M.

    1983-05-01

    The value of intense neutron beams for condensed matter research is discussed with emphasis on the complementary nature of steady state and pulsed neutron sources. A large body of information on neutron sources, both existing and planned, is then summarized under four major headings: fission reactors, electron accelerators with heavy metal targets, pulsed spallation sources and 'steady state' spallation sources. Although the cost of a spallation source is expected to exceed that of a fission reactor of the same flux by a factor of two, there are significant advantages for a spallation device such as the proposed Electronuclear Materials Test Facility (EMTF)

  20. GLOBAL OPTIMIZATION METHODS FOR GRAVITATIONAL LENS SYSTEMS WITH REGULARIZED SOURCES

    International Nuclear Information System (INIS)

    Rogers, Adam; Fiege, Jason D.

    2012-01-01

    Several approaches exist to model gravitational lens systems. In this study, we apply global optimization methods to find the optimal set of lens parameters using a genetic algorithm. We treat the full optimization procedure as a two-step process: an analytical description of the source plane intensity distribution is used to find an initial approximation to the optimal lens parameters; the second stage of the optimization uses a pixelated source plane with the semilinear method to determine an optimal source. Regularization is handled by means of an iterative method and the generalized cross validation (GCV) and unbiased predictive risk estimator (UPRE) functions that are commonly used in standard image deconvolution problems. This approach simultaneously estimates the optimal regularization parameter and the number of degrees of freedom in the source. Using the GCV and UPRE functions, we are able to justify an estimation of the number of source degrees of freedom found in previous work. We test our approach by applying our code to a subset of the lens systems included in the SLACS survey.

  1. Studies on the coupling transformer to improve the performance of microwave ion source.

    Science.gov (United States)

    Misra, Anuraag; Pandit, V S

    2014-06-01

    A 2.45 GHz microwave ion source has been developed and installed at the Variable Energy Cyclotron Centre to produce high intensity proton beam. It is operational and has already produced more than 12 mA of proton beam with just 350 W of microwave power. In order to optimize the coupling of microwave power to the plasma, a maximally flat matching transformer has been used. In this paper, we first describe an analytical method to design the matching transformer and then present the results of rigorous simulation performed using ANSYS HFSS code to understand the effect of different parameters on the transformed impedance and reflection and transmission coefficients. Based on the simulation results, we have chosen two different coupling transformers which are double ridged waveguides with ridge widths of 24 mm and 48 mm. We have fabricated these transformers and performed experiments to study the influence of these transformers on the coupling of microwave to plasma and extracted beam current from the ion source.

  2. Relationships between moment magnitude and fault parameters: theoretical and semi-empirical relationships

    Science.gov (United States)

    Wang, Haiyun; Tao, Xiaxin

    2003-12-01

    Fault parameters are important in earthquake hazard analysis. In this paper, theoretical relationships between moment magnitude and fault parameters including subsurface rupture length, downdip rupture width, rupture area, and average slip over the fault surface are deduced based on seismological theory. These theoretical relationships are further simplified by applying similarity conditions and an unique form is established. Then, combining the simplified theoretical relationships between moment magnitude and fault parameters with seismic source data selected in this study, a practical semi-empirical relationship is established. The seismic source data selected is also to used to derive empirical relationships between moment magnitude and fault parameters by the ordinary least square regression method. Comparisons between semi-empirical relationships and empirical relationships show that the former depict distribution trends of data better than the latter. It is also observed that downdip rupture widths of strike slip faults are saturated when moment magnitude is more than 7.0, but downdip rupture widths of dip slip faults are not saturated in the moment magnitude ranges of this study.

  3. Modeling the contribution of point sources and non-point sources to Thachin River water pollution.

    Science.gov (United States)

    Schaffner, Monika; Bader, Hans-Peter; Scheidegger, Ruth

    2009-08-15

    Major rivers in developing and emerging countries suffer increasingly of severe degradation of water quality. The current study uses a mathematical Material Flow Analysis (MMFA) as a complementary approach to address the degradation of river water quality due to nutrient pollution in the Thachin River Basin in Central Thailand. This paper gives an overview of the origins and flow paths of the various point- and non-point pollution sources in the Thachin River Basin (in terms of nitrogen and phosphorus) and quantifies their relative importance within the system. The key parameters influencing the main nutrient flows are determined and possible mitigation measures discussed. The results show that aquaculture (as a point source) and rice farming (as a non-point source) are the key nutrient sources in the Thachin River Basin. Other point sources such as pig farms, households and industries, which were previously cited as the most relevant pollution sources in terms of organic pollution, play less significant roles in comparison. This order of importance shifts when considering the model results for the provincial level. Crosschecks with secondary data and field studies confirm the plausibility of our simulations. Specific nutrient loads for the pollution sources are derived; these can be used for a first broad quantification of nutrient pollution in comparable river basins. Based on an identification of the sensitive model parameters, possible mitigation scenarios are determined and their potential to reduce the nutrient load evaluated. A comparison of simulated nutrient loads with measured nutrient concentrations shows that nutrient retention in the river system may be significant. Sedimentation in the slow flowing surface water network as well as nitrogen emission to the air from the warm oxygen deficient waters are certainly partly responsible, but also wetlands along the river banks could play an important role as nutrient sinks.

  4. Study of electroweak parameters at LEP

    International Nuclear Information System (INIS)

    Blum, W.

    1991-10-01

    The measurement of the line shape and asymmetry parameters of the Z 0 in its leptonic and hadronic decays are reviewed. Progress is reported about a considerable increase in measurement accuracy. Several tests of the Standard Model confirm it to better than one per cent. New values for the effective mixing parameter are derived from the line shape parameters averaged over the four LEP experiments. The corresponding limits on the top mass are presented. (orig.)

  5. Studies on the production and quality assurance of miniature {sup 125}I radioactive sources suitable for treatment of ocular and prostate cancers

    Energy Technology Data Exchange (ETDEWEB)

    Saxena, S.K. [Therapeutic and Reference Sources Section, Radiopharmaceuticals Division, RLG, BARC, Mumbai-400 085 (India)]. E-mail: snr1991@yahoo.co.in; Shanta, A. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India); Rajurkar, Nilima S. [Department of Chemistry, University of Pune (India); Majali, M.A. [Therapeutic and Reference Sources Section, Radiopharmaceuticals Division, RLG, BARC, Mumbai-400 085 (India)

    2006-04-15

    {sup 125}I sources were prepared by adsorption of {sup 125}I on palladium-coated silver wires. The effect of reducing agent on percentage adsorption of {sup 125}I was studied and the amount of adsorbed activity on source core was studied by repeated adsorption cycles. The activity per source in the sources produced from the same batch varied with coefficient of variation (i.e. the ratio of standard deviation to mean multiplied by 100) less than 10%. The unencapsulated source exhibited low leachability (< 0.01%). The laser parameters were optimized to obtain quality welds with negligible leak rate. The sources were laser-encapsulated in titanium capsules of 0.8 mm (OD)x4.5 mm (l). The release of radioactivity from encapsulated sources in an immersion test at 50 {sup o}C for 5 h was <5 nCi (185 Bq). The surface contamination on the sealed capsules was found to be<0.05 nCi or 1.85 Bq per source. The sources were used in the treatment of a child having retinoblastoma.

  6. Astrophysical parameters of ten poorly studied open star clusters

    International Nuclear Information System (INIS)

    Tadross, Ashraf Latif; El-Bendary, Reda; Osman, Anas; Ismail, Nader; Bakry, Abdel Aziz

    2012-01-01

    We present the fundamental parameters of ten open star clusters, nominated from Kronberger et al. who presented some newly discovered stellar groups on the basis of the Two Micron All Sky Survey photometry and Digitized Sky Survey visual images. Star counts and photometric parameters (radius, membership, distance, color excess, age, luminosity function, mass function, total mass, and dynamical relaxation time) have been determined for these ten clusters for the first time. In order to calibrate our procedures, the main parameters (distance, age, and color excess) have been re-estimated for another five clusters, which are also studied by Kronberger et al. (research papers)

  7. Spillover effects in epidemiology: parameters, study designs and methodological considerations

    Science.gov (United States)

    Benjamin-Chung, Jade; Arnold, Benjamin F; Berger, David; Luby, Stephen P; Miguel, Edward; Colford Jr, John M; Hubbard, Alan E

    2018-01-01

    Abstract Many public health interventions provide benefits that extend beyond their direct recipients and impact people in close physical or social proximity who did not directly receive the intervention themselves. A classic example of this phenomenon is the herd protection provided by many vaccines. If these ‘spillover effects’ (i.e. ‘herd effects’) are present in the same direction as the effects on the intended recipients, studies that only estimate direct effects on recipients will likely underestimate the full public health benefits of the intervention. Causal inference assumptions for spillover parameters have been articulated in the vaccine literature, but many studies measuring spillovers of other types of public health interventions have not drawn upon that literature. In conjunction with a systematic review we conducted of spillovers of public health interventions delivered in low- and middle-income countries, we classified the most widely used spillover parameters reported in the empirical literature into a standard notation. General classes of spillover parameters include: cluster-level spillovers; spillovers conditional on treatment or outcome density, distance or the number of treated social network links; and vaccine efficacy parameters related to spillovers. We draw on high quality empirical examples to illustrate each of these parameters. We describe study designs to estimate spillovers and assumptions required to make causal inferences about spillovers. We aim to advance and encourage methods for spillover estimation and reporting by standardizing spillover parameter nomenclature and articulating the causal inference assumptions required to estimate spillovers. PMID:29106568

  8. Studies and modeling of cold neutron sources

    International Nuclear Information System (INIS)

    Campioni, G.

    2004-11-01

    With the purpose of updating knowledge in the fields of cold neutron sources, the work of this thesis has been run according to the 3 following axes. First, the gathering of specific information forming the materials of this work. This set of knowledge covers the following fields: cold neutron, cross-sections for the different cold moderators, flux slowing down, different measurements of the cold flux and finally, issues in the thermal analysis of the problem. Secondly, the study and development of suitable computation tools. After an analysis of the problem, several tools have been planed, implemented and tested in the 3-dimensional radiation transport code Tripoli-4. In particular, a module of uncoupling, integrated in the official version of Tripoli-4, can perform Monte-Carlo parametric studies with a spare factor of Cpu time fetching 50 times. A module of coupling, simulating neutron guides, has also been developed and implemented in the Monte-Carlo code McStas. Thirdly, achieving a complete study for the validation of the installed calculation chain. These studies focus on 3 cold sources currently functioning: SP1 from Orphee reactor and 2 other sources (SFH and SFV) from the HFR at the Laue Langevin Institute. These studies give examples of problems and methods for the design of future cold sources

  9. Lattice Study for the Taiwan Photon Source

    CERN Document Server

    Kuo, Chin-Cheng; Chen Chien Te; Luo, Gwo-Huei; Tsai, Hung-Jen; Wang, Min-Huey

    2005-01-01

    The feasibility study for the new 3.0~3.3 GeV Taiwan synchrotron light source, dubbed Taiwan Photon Source, was initiated in July, 2004. The goal is to construct a high performance light source with extremely bright X-ray in complementary to the existing 1.5 GeV light source in Taiwan. The ring circumference is 518.4 m and a 24-cell DBA lattice structure is chosen. The natural emittance with distributed dispersion is less than 2 nm-rad. A large booster ring of 499.2 m sharing the storage ring tunnel will be adopted.

  10. Geotechnical parameters for three deep ocean study areas

    International Nuclear Information System (INIS)

    Nicholson, D.P.

    1989-01-01

    This chapter summarizes the results of geotechnical measurements made on cores taken at the three deep ocean sites that have been studied in detail as part of the international programme assessing the feasibility of deep ocean disposal of heat-generating radioactive waste. The capabilities of existing sampling methods and the adequacy of the available data for providing the geotechnical parameters needed to evaluate the technical feasibility of deep ocean disposal are discussed. It is concluded that, while it has not been possible to obtain core samples of sufficient quality and depth to provide all the parameters needed for the assessment, no fundamental differences between the sediments at the study areas and those found on land or in shallow water have been identified. (author)

  11. Reactor parameters for European economic, safety and environmental studies

    International Nuclear Information System (INIS)

    Hancox, R.; Cooke, P.I.H.; Spears, W.R.

    1990-01-01

    Parameter sets for five 1200 MW e tokamak reactors were developed for the European Study Group on the Environmental, Safety-related and Economic Potential of Fusion Power, showing today's perception of the range of reactors likely to be available as a result of the Commission's fusion programme. On the basis of the cost of generating electricity, relative to a fission reactor, a reference set was chosen and endorsed by the Group for further studies including that on the environmental impact of fusion power. Key physics and technology parameters for the reference reactor are compared with values used in the ITER design, and with those from American studies. (author)

  12. Neutron source strength associated with FTR fuel

    International Nuclear Information System (INIS)

    Boroughs, G.L.; Bunch, W.L.; Johnson, D.L.

    1975-01-01

    The study presented shows the important effect of shelf life on the neutron source strength anticipated from fuel irradiated in the FTR. The neutron source strength will be enhanced appreciably by extended shelf lives. High neutron source strengths will also be associated with reprocessed LWR plutonium, which is expected to contain a greater abundance of the higher isotopes. The branching ratio and cross section of 241 Am is an important parameter that needs to be defined more precisely to establish calculated values with greater precision

  13. Study of Second Phase Particles and Fe content in Zr Alloys Using the Advanced Photon Source at Argonne

    Energy Technology Data Exchange (ETDEWEB)

    Arthur T. Motta

    2001-11-07

    We have conducted a study of second phase particles and matrix alloying element concentrations in zirconium alloys using synchrotron radiation from the Advanced Photon Source (APS) at Argonne National Laboratory. The high flux of synchrotron radiation delivered at the 2BM beamline compared to conventional x-ray generators, enables the detection of very small precipitate volume fractions. We detected the standard C14 hcp Zr(Cr,Fe)2 precipitates, (the stable second phase in Zircaloy-4) in the bulk material at a cumulative annealing parameter as low as 10-20 h, and we followed the kinetics of precipitation and growth as a function of the cumulative annealing parameter (CAP) in the range 10-22 (quench) to 10-16 h. In addition, the unique combination of spatial resolution and elemental sensitivity of the 2ID-D/E microbeam line at the Advanced Photon Source at Argonne (APS) allows study of the alloying element concentrations at ppm levels in an area as small as 0.2 mm. We used x-ray fluorescence induced by this sub-micron x-ray beam to determine the concentration of these alloying elements in the matrix as a function of alloy type and thermal history. We discuss these results and the potential of synchrotron radiation-based techniques for studying zirconium alloys.

  14. Study of Second Phase Particles and Fe content in Zr Alloys Using the Advanced Photon Source at Argonne

    International Nuclear Information System (INIS)

    Motta, Arthur T.

    2001-01-01

    We have conducted a study of second phase particles and matrix alloying element concentrations in zirconium alloys using synchrotron radiation from the Advanced Photon Source (APS) at Argonne National Laboratory. The high flux of synchrotron radiation delivered at the 2BM beamline compared to conventional x-ray generators, enables the detection of very small precipitate volume fractions. We detected the standard C14 hcp Zr(Cr,Fe)2 precipitates, (the stable second phase in Zircaloy-4) in the bulk material at a cumulative annealing parameter as low as 10-20 h, and we followed the kinetics of precipitation and growth as a function of the cumulative annealing parameter (CAP) in the range 10-22 (quench) to 10-16 h. In addition, the unique combination of spatial resolution and elemental sensitivity of the 2ID-D/E microbeam line at the Advanced Photon Source at Argonne (APS) allows study of the alloying element concentrations at ppm levels in an area as small as 0.2 mm. We used x-ray fluorescence induced by this sub-micron x-ray beam to determine the concentration of these alloying elements in the matrix as a function of alloy type and thermal history. We discuss these results and the potential of synchrotron radiation-based techniques for studying zirconium alloys

  15. 42 CFR 456.244 - Data sources for studies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Data sources for studies. 456.244 Section 456.244 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES...: Medical Care Evaluation Studies § 456.244 Data sources for studies. Data that the committee uses to...

  16. 42 CFR 456.144 - Data sources for studies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Data sources for studies. 456.144 Section 456.144 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Care Evaluation Studies § 456.144 Data sources for studies. Data that the committee uses to perform...

  17. Asymmetric Joint Source-Channel Coding for Correlated Sources with Blind HMM Estimation at the Receiver

    Directory of Open Access Journals (Sweden)

    Ser Javier Del

    2005-01-01

    Full Text Available We consider the case of two correlated sources, and . The correlation between them has memory, and it is modelled by a hidden Markov chain. The paper studies the problem of reliable communication of the information sent by the source over an additive white Gaussian noise (AWGN channel when the output of the other source is available as side information at the receiver. We assume that the receiver has no a priori knowledge of the correlation statistics between the sources. In particular, we propose the use of a turbo code for joint source-channel coding of the source . The joint decoder uses an iterative scheme where the unknown parameters of the correlation model are estimated jointly within the decoding process. It is shown that reliable communication is possible at signal-to-noise ratios close to the theoretical limits set by the combination of Shannon and Slepian-Wolf theorems.

  18. Comparative study of surrogate models for groundwater contamination source identification at DNAPL-contaminated sites

    Science.gov (United States)

    Hou, Zeyu; Lu, Wenxi

    2018-05-01

    Knowledge of groundwater contamination sources is critical for effectively protecting groundwater resources, estimating risks, mitigating disaster, and designing remediation strategies. Many methods for groundwater contamination source identification (GCSI) have been developed in recent years, including the simulation-optimization technique. This study proposes utilizing a support vector regression (SVR) model and a kernel extreme learning machine (KELM) model to enrich the content of the surrogate model. The surrogate model was itself key in replacing the simulation model, reducing the huge computational burden of iterations in the simulation-optimization technique to solve GCSI problems, especially in GCSI problems of aquifers contaminated by dense nonaqueous phase liquids (DNAPLs). A comparative study between the Kriging, SVR, and KELM models is reported. Additionally, there is analysis of the influence of parameter optimization and the structure of the training sample dataset on the approximation accuracy of the surrogate model. It was found that the KELM model was the most accurate surrogate model, and its performance was significantly improved after parameter optimization. The approximation accuracy of the surrogate model to the simulation model did not always improve with increasing numbers of training samples. Using the appropriate number of training samples was critical for improving the performance of the surrogate model and avoiding unnecessary computational workload. It was concluded that the KELM model developed in this work could reasonably predict system responses in given operation conditions. Replacing the simulation model with a KELM model considerably reduced the computational burden of the simulation-optimization process and also maintained high computation accuracy.

  19. Acquisition system of tandem injector parameters

    International Nuclear Information System (INIS)

    Decourt, M.

    1986-01-01

    The system centralizes all the parameters belonging to the accelerator injector. The acquisition center system reinforces an original device made of cameras and video receivers. Besides giving access to all the parameters of the ion source, the new system allows, in the ''OSCILLO'' mode, to visualize in real time any channel on the oscilloscope [fr

  20. Studying Air Quality Dynamics using A Linear Genetic Programming Approach over Remotely Sensed Atmospheric Parameters: case study (Cairo, Egypt)

    Science.gov (United States)

    El-Askary, H. M.; Sheta, W.; Prasad, A. K.; Ali, H.; Abdel rahman, M.; El-Desouki, A.; Kafatos, M.

    2011-12-01

    For the past nine years starting from 2000, Cairo and the Delta region have been going through seriously high air pollution episodes that take place from October till November, locally known as the "Black Cloud". These temperature inversion episodes are attributed to Cairo's topography, complex climate systems, in addition to its economic growth and industrial activity and the long range transport from Europe. Carbon monoxide, ozone, methane, and water vapor are four major parameters that give an indication to the levels of pollution due to their interactions in the atmosphere. Carbon monoxide is especially an excellent tracer for pollution sources and pathways in the troposphere. The Nile Delta is known to be the most populous region of Egypt with major agricultural and industrial activities. The region suffers from intense episodes of natural and anthropogenic pollution especially during Spring (MAM), Summer (JJA), Fall (SON), and Winter (DJF) seasons. Previous studies found that the summer season shows long range transport of pollutants from Europe which is widely accepted. Recent studies attribute the local biomass burning in open fields to be the major culprit behind increased levels of pollution over major cities of the Delta region (such as Cairo) especially during the Fall season. Such episodes result in dense fog and haze which is locally known as "Black Cloud". We have analyzed multiple satellite datasets such as MODIS higher resolution daily aerosol parameters, vertical profiles from AIRS (meteorological and other parameters), HYSPLIT and GOCART models, and ground collected data (AOD, PM10, SO2 and NO2) to study the cause of Fall-time pollution over the Delta region. In this research we analysed aerosol, water vapor and cloud properties, over Cairo and the Greater Delta region starting from March 1st 2000 till May 31st 2010. The parameters involved in this analysis include nine parameters noted as P0 to P8 namely: Angstrom Exponent Land Mean, Atmospheric

  1. SPOTting Model Parameters Using a Ready-Made Python Package.

    Directory of Open Access Journals (Sweden)

    Tobias Houska

    Full Text Available The choice for specific parameter estimation methods is often more dependent on its availability than its performance. We developed SPOTPY (Statistical Parameter Optimization Tool, an open source python package containing a comprehensive set of methods typically used to calibrate, analyze and optimize parameters for a wide range of ecological models. SPOTPY currently contains eight widely used algorithms, 11 objective functions, and can sample from eight parameter distributions. SPOTPY has a model-independent structure and can be run in parallel from the workstation to large computation clusters using the Message Passing Interface (MPI. We tested SPOTPY in five different case studies to parameterize the Rosenbrock, Griewank and Ackley functions, a one-dimensional physically based soil moisture routine, where we searched for parameters of the van Genuchten-Mualem function and a calibration of a biogeochemistry model with different objective functions. The case studies reveal that the implemented SPOTPY methods can be used for any model with just a minimal amount of code for maximal power of parameter optimization. They further show the benefit of having one package at hand that includes number of well performing parameter search methods, since not every case study can be solved sufficiently with every algorithm or every objective function.

  2. Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

    International Nuclear Information System (INIS)

    Sina, S.; Faghihi, R.; Meigooni, A. S.; Mehdizadeh, S.; Zehtabian, M.; Mosleh-Shirazi, M. A.

    2009-01-01

    The dose rate distribution delivered by a low dose rate 137 Cs pellet source, a spherical source used within the source trains Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet source and the AAPM TG-43 parameters were computed. A spherical phantom with dimensions large enough (60 cm) was used to provide full scattering conditions. In order to score dose at different distances from the source centre, this sphere was divided into a set of 600 concentric spherical shells of 0.05 cm thickness. The calculations were performed up to a distance of 10 cm from the source centre. To calculate the effect of the applicator and dummy pellets on dose rate constant and radial dose function, a single pellet source was simulated inside the vaginal applicator, and spherical tally cells with radius of 0.05 cm were used in the simulations. The F6 tally was used to score the absolute dose rate at a given point in the phantom. Results: The dose rate constant for a single active pellet was found to be 1.102±0.007 cGyh -1 U -1 , and the dose rate constant for an active pellet inside the applicator was 1.095±0.009 cGyh -1 U -l . The tabulated data and 5th order polynomial fit coefficients for the radial dose function along with the dose rate constant are provided for both cases. The effect of applicator and dummy pellets on anisotropy function of the source was also investigated. Conclusion: The error resulting from ignoring the applicator was reduced using the data of a single pellet. The results indicate that F(r, θ) decreases towards the applicator.

  3. Program for parameter studies of steam generators

    International Nuclear Information System (INIS)

    Mathisen, R.P.

    1982-11-01

    R2-GEN is a computer code for stationary thermal parameter studies of steam generators. The geometry and data are valid for Ringhals-2 generators. Subroutines and relevant calculations are included. The program is based on a heterogeneous flow model and some applications on tubes with varying contamination are presented. (G.B.)

  4. Study of pipe-whip parameters in pipelines

    International Nuclear Information System (INIS)

    Guerreiro, J.N.C.; Loula, A.F.D.; Galeao, A.C.N.R.

    1980-01-01

    The problem of the high energy pipe-whip, assuming an elastic-plastic behavior for the tube material and taking in account the internal pressure, is studied. The constraints are simulated as bilinear springs and viscous dampers. A general research, based on the finite element method was developed to analyse the phenomenon. The influence of the following parameters: gap, damping coefficient, stiffness, constraints positioning and internal pressure of the tube is studied. (Author) [pt

  5. The study of LED light source illumination conditions for ideal algae cultivation

    Science.gov (United States)

    Tsai, Chun-Chin; Huang, Chien-Fu; Chen, Cin-Fu; Yue, Cheng-Feng

    2017-02-01

    Utilizing LED light source modules with 3 different RGB colors, the illumination effect of different wavelengths had been investigated on the growth curve of the same kind of micro algae. It was found that the best micro algae culturing status came out with long wavelength light such as red light (650 670 nm). Based on the same condition for a period of 3 weeks , the grown micro algae population density ratio represented by Optical Density (O.D.) ratio is 1?0.4?0.7 corresponding to growth with Red, Green, Blue light sources, respectively. Mixing 3 types and 2 types of LEDs with different parameters, the grown micro algae population densities were compared in terms of O.D. Interestingly enough, different light sources resulted in significant discoloration on micro algae growth, appearing yellow, brown, green, etc. Our experiments results showed such discoloration effect is reversible. Based on the same lighting condition, micro algae growth can be also affected by incubator size, nutrition supply, and temperature variation. In recent years, micro algae related technologies have been international wise a hot topic of energy and environmental protection for research and development institutes, and big energy companies among those developed countries. There will be an economically prosperous future. From this study of LED lighting to ideal algae cultivation, it was found that such built system would be capable of optimizing artificial cultivation system, leading to economic benefits for its continuous development. Since global warming causing weather change, accompanying with reducing energy sources and agriculture growth shortage are all threatening human being survival.

  6. Optimal Laser Phototherapy Parameters for Pain Relief.

    Science.gov (United States)

    Kate, Rohit J; Rubatt, Sarah; Enwemeka, Chukuka S; Huddleston, Wendy E

    2018-03-27

    Studies on laser phototherapy for pain relief have used parameters that vary widely and have reported varying outcomes. The purpose of this study was to determine the optimal parameter ranges of laser phototherapy for pain relief by analyzing data aggregated from existing primary literature. Original studies were gathered from available sources and were screened to meet the pre-established inclusion criteria. The included articles were then subjected to meta-analysis using Cohen's d statistic for determining treatment effect size. From these studies, ranges of the reported parameters that always resulted into large effect sizes were determined. These optimal ranges were evaluated for their accuracy using leave-one-article-out cross-validation procedure. A total of 96 articles met the inclusion criteria for meta-analysis and yielded 232 effect sizes. The average effect size was highly significant: d = +1.36 (confidence interval [95% CI] = 1.04-1.68). Among all the parameters, total energy was found to have the greatest effect on pain relief and had the most prominent optimal ranges of 120-162 and 15.36-20.16 J, which always resulted in large effect sizes. The cross-validation accuracy of the optimal ranges for total energy was 68.57% (95% CI = 53.19-83.97). Fewer and less-prominent optimal ranges were obtained for the energy density and duration parameters. None of the remaining parameters was found to be independently related to pain relief outcomes. The findings of meta-analysis indicate that laser phototherapy is highly effective for pain relief. Based on the analysis of parameters, total energy can be optimized to yield the largest effect on pain relief.

  7. A numerical study of non-linear crack tip parameters

    Directory of Open Access Journals (Sweden)

    F.V. Antunes

    2015-07-01

    Full Text Available Crack closure concept has been widely used to explain different issues of fatigue crack propagation. However, different authors have questioned the relevance of crack closure and have proposed alternative concepts. The main objective here is to check the effectiveness of crack closure concept by linking the contact of crack flanks with non-linear crack tip parameters. Accordingly, 3D-FE numerical models with and without contact were developed for a wide range of loading scenarios and the crack tip parameters usually linked to fatigue crack growth, namely range of cyclic plastic strain, crack tip opening displacement, size of reversed plastic zone and total plastic dissipation per cycle, were investigated. It was demonstrated that: i LEFM concepts are applicable to the problem under study; ii the crack closure phenomenon has a great influence on crack tip parameters decreasing their values; iii the Keff concept is able to explain the variations of crack tip parameters produced by the contact of crack flanks; iv the analysis of remote compliance is the best numerical parameter to quantify the crack opening level; v without contact there is no effect of stress ratio on crack tip parameters. Therefore it is proved that the crack closure concept is valid.

  8. The TRIUMF compact DC H-/D- ion source

    International Nuclear Information System (INIS)

    Jayamanna, K.; McDonald, M.; Yuan, D.H.; Schmor, P.W.

    1990-06-01

    A compact dc H - /D - ion source using multicusp magnetic plasma confinement, has been experimentally studied and optimized on the TRIUMF ion source test stand. The plasma parameters have been obtained with rapid computer controlled Langmuir probe scans. The extraction electrode configuration, originally tailored to the TR30 cyclotron requirements, has been further developed. With a 12 mm diameter extraction hole this source now provides 9 mA within a normalized emittance of 0.44 π mm-mrad and can be easily modified for lower currents of smaller emittance (1 mA H - current with normalized emittance 0.12π.mm-mrad or 7 mA H - current with normalized emittance 0.34π.mm-mrad). The source has proven to have low maintenance, high reliability and long filament lifetime. This paper emphasizes basic plasma parameters which determine the efficiency of H - /D - production. Some experimental results obtained from several versions of the extraction system are also described. (Author) 6 refs., 8 figs

  9. The reaction between iodine and silver under severe PWR accident conditions. An experimental parameter study

    Energy Technology Data Exchange (ETDEWEB)

    Funke, F; Greger, G U; Bleier, A; Hellmann, S; Morell, W [Siemens AG, Power Generation Group, Erlangen (Germany)

    1996-12-01

    An extensive experimental parameter study was performed on the kinetics in the reaction system I{sub 2}/Ag and I{sup -}/Ag in a laboratory-scale apparatus.Starting with I{sub 2} or I{sup -} solutions and silver powder suspensions, the decrease of soluted I{sub 2} or I{sup -}, respectively, due to fixation on the silver particles, was monitored as function of time using the radioactive tracer I-131. The measured data were analyzed using a model of first order kinetics with respect to the iodine concentration. However, the analysis using first order kinetics had to be performed separately in an early, fast reaction phase and in a late, slow reaction phase. The reason for this unexpected behaviour was not identified. Thus, rate constant, two for each test, were deduced from 14 I{sub 2}/Ag main tests and from 36 I{sup -}/Ag tests. No dependencies of the rate constants were found on the parameters temperature, initial iodine concentration, presence of boric acid, type of silver educt, and pretreatment of the silver educt prior to the tests. However, the stirring of the reaction solution generally enhanced the kinetics highlighting the importance of mass transfer. The I{sup -}/Ag reaction proceeded only if there was no inertization of the reaction solution by sparging with nitrogen. The temperature-independent rate constant for the early, fast I{sub 2}/Ag reaction phase is 2E-5 m/s. However, a smaller rate constant of 6E-6 m/s is recommended for use in source term calculations with IMPAIR, which already contains a first order model. Analogously, the temperature-independent I{sup -}/Ag reaction rate constant is 8E-6 m/s in an early, fast reaction phase. For use in source term calculations, a smaller rate constant of 2E-6 m/s is recommended. The lower bound of the I{sup -}/Ag rate constant was 3E-8 m/s which could be used in very conservative source term calculations. (author) 20 figs., 6 tabs., 15 refs.

  10. Effects of Source RDP Models and Near-source Propagation: Implication for Seismic Yield Estimation

    Science.gov (United States)

    Saikia, C. K.; Helmberger, D. V.; Stead, R. J.; Woods, B. B.

    - It has proven difficult to uniquely untangle the source and propagation effects on the observed seismic data from underground nuclear explosions, even when large quantities of near-source, broadband data are available for analysis. This leads to uncertainties in our ability to quantify the nuclear seismic source function and, consequently the accuracy of seismic yield estimates for underground explosions. Extensive deterministic modeling analyses of the seismic data recorded from underground explosions at a variety of test sites have been conducted over the years and the results of these studies suggest that variations in the seismic source characteristics between test sites may be contributing to the observed differences in the magnitude/yield relations applicable at those sites. This contributes to our uncertainty in the determination of seismic yield estimates for explosions at previously uncalibrated test sites. In this paper we review issues involving the relationship of Nevada Test Site (NTS) source scaling laws to those at other sites. The Joint Verification Experiment (JVE) indicates that a magnitude (mb) bias (δmb) exists between the Semipalatinsk test site (STS) in the former Soviet Union (FSU) and the Nevada test site (NTS) in the United States. Generally this δmb is attributed to differential attenuation in the upper-mantle beneath the two test sites. This assumption results in rather large estimates of yield for large mb tunnel shots at Novaya Zemlya. A re-examination of the US testing experiments suggests that this δmb bias can partly be explained by anomalous NTS (Pahute) source characteristics. This interpretation is based on the modeling of US events at a number of test sites. Using a modified Haskell source description, we investigated the influence of the source Reduced Displacement Potential (RDP) parameters ψ ∞ , K and B by fitting short- and long-period data simultaneously, including the near-field body and surface waves. In general

  11. Effects of Supplemental Chromium Source and Concentration on Growth, Carcass Characteristics, and Serum Lipid Parameters of Broilers Reared Under Normal Conditions.

    Science.gov (United States)

    Zheng, Cancai; Huang, Yanling; Xiao, Fang; Lin, Xi; Lloyd, Karen

    2016-02-01

    An experiment was conducted to investigate the effects of dietary chromium (Cr) source and concentration on growth performance, carcass traits, and some serum lipid parameters of broilers under normal rearing conditions for 42 days. A total of 252 1-day-old Cobb 500 commercial female broilers were randomly allotted by body weight (BW) to one of six replicate cages (six broilers per cage) for each of seven treatments in a completely randomized design involved in a 2 × 3 factorial arrangement of treatments with three Cr sources (Cr propionate (CrPro), Cr picolinate (CrPic), Cr chloride (CrCl3)) and two concentrations of added Cr (0.4 and 2.0 mg of Cr/kg) plus a Cr-unsupplemented control diet. The results showed that dietary Cr supplementation tended to increase the breast muscle percentage compared with the Cr-unsupplemented control group (P = 0.0784), while Cr from CrPic tended to have higher breast muscle percentage compared with Cr from CrCl3 (P = 0.0881). Chromium from CrPic also tended to increase the breast intramuscular fat (IMF) compared with Cr from CrCl3 (P = 0.0648). In addition, supplementation of 0.4 mg/kg Cr tended to decrease low-density lipoprotein cholesterol (LDL-C) (P = 0.0614). Compared with the control group, broilers fed Cr-supplemented diets had higher triglyceride (TG) (P = 0.0129) regardless of Cr source and Cr concentration. Chromium from CrPro and CrPic had lower total cholesterol (TC) compared with Cr from CrCl3 (P = 0.0220). These results indicate that dietary supplementation of Cr has effects on carcass characteristics and serum lipid parameters of broilers under normal rearing conditions, while supplementation of organic Cr can improve carcass characteristics and reduce the cholesterol content in serum.

  12. Source Estimation by Full Wave Form Inversion

    Energy Technology Data Exchange (ETDEWEB)

    Sjögreen, Björn [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Center for Applied Scientific Computing; Petersson, N. Anders [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Center for Applied Scientific Computing

    2013-08-07

    Given time-dependent ground motion recordings at a number of receiver stations, we solve the inverse problem for estimating the parameters of the seismic source. The source is modeled as a point moment tensor source, characterized by its location, moment tensor components, the start time, and frequency parameter (rise time) of its source time function. In total, there are 11 unknown parameters. We use a non-linear conjugate gradient algorithm to minimize the full waveform misfit between observed and computed ground motions at the receiver stations. An important underlying assumption of the minimization problem is that the wave propagation is accurately described by the elastic wave equation in a heterogeneous isotropic material. We use a fourth order accurate finite difference method, developed in [12], to evolve the waves forwards in time. The adjoint wave equation corresponding to the discretized elastic wave equation is used to compute the gradient of the misfit, which is needed by the non-linear conjugated minimization algorithm. A new source point moment source discretization is derived that guarantees that the Hessian of the misfit is a continuous function of the source location. An efficient approach for calculating the Hessian is also presented. We show how the Hessian can be used to scale the problem to improve the convergence of the non-linear conjugated gradient algorithm. Numerical experiments are presented for estimating the source parameters from synthetic data in a layer over half-space problem (LOH.1), illustrating rapid convergence of the proposed approach.

  13. Noise study of all-normal dispersion supercontinuum sources for potential application in optical coherence tomography

    DEFF Research Database (Denmark)

    Bravo Gonzalo, Ivan; Engelsholm, Rasmus Dybbro; Bang, Ole

    2017-01-01

    bandwidths, such sources are characterized by large intensity fluctuations, limiting their performance for applications in imaging such as optical coherence tomography (OCT). An approach to eliminate the influence of noise sensitive effects is to use a so-called all-normal dispersion (ANDi) fiber, in which...... the dispersion is normal for all the wavelengths of interest. Pumping these types of fibers with short enough femtosecond pulses allows to suppress stimulated Raman scattering (SRS), which is known to be as noisy process as modulation instability (MI), and coherent SC is generated through self-phase modulation...... (SPM) and optical wave breaking (OWB). In this study, we show the importance of the pump laser and fiber parameters in the design of low-noise ANDi based SC sources, for application in OCT. We numerically investigate the pulse-to-pulse fluctuations of the SC, calculating the relative intensity noise...

  14. Calculation of source terms for NUREG-1150

    International Nuclear Information System (INIS)

    Breeding, R.J.; Williams, D.C.; Murfin, W.B.; Amos, C.N.; Helton, J.C.

    1987-10-01

    The source terms estimated for NUREG-1150 are generally based on the Source Term Code Package (STCP), but the actual source term calculations used in computing risk are performed by much smaller codes which are specific to each plant. This was done because the method of estimating the uncertainty in risk for NUREG-1150 requires hundreds of source term calculations for each accident sequence. This is clearly impossible with a large, detailed code like the STCP. The small plant-specific codes are based on simple algorithms and utilize adjustable parameters. The values of the parameters appearing in these codes are derived from the available STCP results. To determine the uncertainty in the estimation of the source terms, these parameters were varied as specified by an expert review group. This method was used to account for the uncertainties in the STCP results and the uncertainties in phenomena not considered by the STCP

  15. Delivery parameters, neonatal parameters and incidence of urinary incontinence six months postpartum: a cohort study.

    Science.gov (United States)

    Wesnes, Stian Langeland; Hannestad, Yngvild; Rortveit, Guri

    2017-10-01

    Contradictory results have been reported regarding most delivery parameters as risk factors for urinary incontinence. We investigated the association between the incidence of urinary incontinence six months postpartum and single obstetric risk factors as well as combinations of risk factors. This study was based on the Norwegian Mother and Child Cohort Study, conducted by the Norwegian Institute of Public Health during 1998-2008. This substudy was based on 7561 primiparous women who were continent before and during pregnancy. Data were obtained from questionnaires answered at weeks 15 and 30 of pregnancy and six months postpartum. Data were linked to the Medical Birth Registry of Norway. Single and combined delivery- and neonatal parameters were analyzed by logistic regression analyses. Birthweight was associated with significantly higher risk of urinary incontinence six months postpartum [3541-4180 g: odds ratio (OR) 1.4, 95% confidence interval (CI) 1.2-1.6; >4180 g: OR 1.6, 95% CI 1.2-2.0]. Fetal presentation, obstetric anal sphincter injuries, episiotomy and epidural analgesia were not significantly associated with increased risk of urinary incontinence. The following combinations of risk factors among women delivering by spontaneous vaginal delivery increased the risk of urinary incontinence six months postpartum; birthweight ≥3540 g and ≥36 cm head circumference; birthweight ≥3540 g and forceps, birthweight ≥3540 g and episiotomy; and ≥36 cm head circumference and episiotomy. Some combinations of delivery parameters and neonatal parameters seem to act together and may increase the risk of incidence of urinary incontinence six months postpartum in a synergetic way. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  16. Exergy analysis and parameter study on a novel auto-cascade Rankine cycle

    International Nuclear Information System (INIS)

    Bao, Junjiang; Zhao, Li

    2012-01-01

    A novel auto-cascade Rankine cycle (ARC) is proposed to reduce thermodynamics irreversibility and improve energy utilization. Like the Kalina cycle, the working fluid for the ARC is zeotropic mixture, which can improve the system efficiency due to the temperature slip that zeotropic mixtures exhibit during phase change. Unlike the Kalina cycle, two expanders are included in the ARC rather than a expander and a throttling valve in the Kalina cycle, which means more work can be obtained. Using the exhaust gas as the heat source and water as the heat sink, a program is written by Matlab 2010a to carry out exergy analysis and parameter study on the ARC. Results show that the R245fa mass fraction in the primary circuit exists an optimum value with respect to the minimum total cycle irreversibility. The largest exergy loss occurs in evaporator, followed by the superheater, condenser, regenerator and IHE (Internal heat exchanger). As the R245fa mass fraction increases, the exergy losses of different components vary diversely. With the evaporation pressure rises, the total cycle irreversibility decreases and work output increases. Separator temperature has a greater influence on the system performance than superheating temperature. Compared with ORC (organic Rankine cycle) and Kalina cycle in the literature, the ARC has proven to be thermodynamically better. -- Highlights: ► We have proposed a novel auto-cascade Rankine cycle (ARC) system. ► The zeotropic mixture Isopentane/R245fa is employed in this system. ► Exergy analysis and parameter study on the ARC are presented. ► Compared with ORC and Kalina cycle in the literature, the ARC has proven to be thermodynamically better.

  17. Stochastic Parameter Development for PORFLOW Simulations of the Hanford AX Tank Farm

    International Nuclear Information System (INIS)

    Ho, C.K.; Baca, R.G.; Conrad, S.H.; Smith, G.A.; Shyr, L.; Wheeler, T.A.

    1999-01-01

    Parameters have been identified that can be modeled stochastically using PORFLOW and Latin Hypercube Sampling (LHS). These parameters include hydrologic and transport properties in the vadose and saturated zones, as well as source-term parameters and infiltration rates. A number of resources were used to define the parameter distributions, primarily those provided in the Retrieval Performance Evaluation Report (Jacobs, 1998). A linear rank regression was performed on the vadose-zone hydrologic parameters given in Khaleel and Freeman (1995) to determine if correlations existed between pairs of parameters. No strong correlations were found among the vadose-zone hydrologic parameters, and it was recommended that these parameters be sampled independently until future data or analyses reveal a strong correlation or functional relationship between parameters. Other distributions for source-term parameters, infiltration rates, and saturated-zone parameters that are required to stochastically analyze the performance of the AX Tank Farm using LHS/PORFLOW were adapted from distributions and values reported in Jacobs (1998) and other literature sources. Discussions pertaining to the geologic conceptualization, vadose-zone modeling, and saturated-zone modeling of the AX Tank Farm are also presented

  18. Residual waters treatment by heterogeneous photocatalysis: a study of experimental parameters applied to the photoelectrocatalysis

    Directory of Open Access Journals (Sweden)

    Henrique de Santana

    2006-02-01

    Full Text Available In this paper, the use of electrochemically-assisted heterogeneous photo-catalysis will be discussed. Several operational parameters will also be discussed, in order to achieve optimum efficiency of this photo-degradation system, such as: the influence of variables as support electrolyte, applied potential, dye initial concentration, pH and choice of a UV source on dye degradation.

  19. An experimental study on effect of process parameters in deep ...

    African Journals Online (AJOL)

    The effects of various deep drawing process parameters were determined by experimental study with the use of Taguchi fractional factorial design and analysis of variance for AA6111 Aluminum alloy. The optimum process parameters were determined based on their influence on the thickness variation at different regions ...

  20. Comparison between commercial and open-source SCADA packages-A case study

    International Nuclear Information System (INIS)

    Barana, O.; Barbato, P.; Breda, M.; Capobianco, R.; Luchetta, A.; Molon, F.; Moressa, M.; Simionato, P.; Taliercio, C.; Zampiva, E.

    2010-01-01

    SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma) is a new experimental device under development at Consorzio RFX aimed at providing a full-scale ion source prototype for MITICA (Megavolt ITer Injector and Concept Advance), the experiment devoted at supplying a full-scale prototype of the ITER Heating Neutral Beam Injector (HNB). Both experimental devices will be hosted in a new facility known as PRIMA (Padova Research on Injectors Megavolt Accelerated). The correct operation of SPIDER and MITICA will be guaranteed by process automation and plant monitoring that will be implemented using suitable controllers (cycle time greater than 10 ms) in conjunction with appropriate SCADA (Supervisory Control And Data Acquisition) software. This paper presents the tests performed at Consorzio RFX to evaluate commercial and open-source SCADA packages and prepare a technical base for the selection of the SCADA system for SPIDER. Two commercial solutions and two open-source solutions (EPICS and TANGO) were investigated. The typical test-bed was represented by a SCADA system exchanging data with a PLC (Programmable Logic Controller). The case study consisted of: (a) the development of a minimal panel provided with fields for setting parameters and of a trend window; (b) the set-up of two kinds of communication, a direct connection between the SCADA and the PLC and an indirect one by means of an OPC (Object Linking and Embedding for Process Control) server. The communication performance was evaluated measuring the network traffic with a fixed number of data variables exchanged and different polling cycle times. The conclusions show that the final choice of a SCADA package for SPIDER will be between one commercial SCADA and EPICS. This choice will not depend uniquely on the results of the tests, but will be also dictated by the early schedule of the SPIDER operations.

  1. Photon statistics characterization of a single-photon source

    International Nuclear Information System (INIS)

    Alleaume, R; Treussart, F; Courty, J-M; Roch, J-F

    2004-01-01

    In a recent experiment, we reported the time-domain intensity noise measurement of a single-photon source relying on single-molecule fluorescence control. In this paper, we present data processing starting from photocount timestamps. The theoretical analytical expression of the time-dependent Mandel parameter Q(T) of an intermittent single-photon source is derived from ON↔OFF dynamics. Finally, source intensity noise analysis, using the Mandel parameter, is quantitatively compared with the usual approach relying on the time autocorrelation function, both methods yielding the same molecular dynamical parameters

  2. Parameters of atmospheric radioactivity in Bulgaria

    International Nuclear Information System (INIS)

    Yaneva, B.; Todorov, P.; Georgieva, D.

    2006-01-01

    Bulgaria is a country which is located on the Balkan Peninsula, at the Eastern part of Europe. There are a lot of polluting sources, which can affect the environmental parameters and human health. One of these parameters is a radioactivity. It can be as a result from natural and anthropological sources. One of the most important sources of radiological influence to the environment and its components is from atmosphere. Anthropological sources of atmospheric pollution are Nuclear power plants, different kinds of industrial plants, and so on. The systematic control on these parameters is made by the Ministry of environment and water in Bulgaria. The atmospheric radioactivity research is based on collecting of many samples and its examine. The collecting of these aerosol samples on different kind of filters is automatic and it is put into practice by fixed stations located in some of the main towns in Bulgaria - Sofia, Varna, Burgas, Vratza and Montana. The required amount of air for each sample is 1000m 3 . These samples are analyzed by gamma-spectrometry analysis for determination of specifies activity of natural and anthropological radionuclides in them. Monitoring data for the atmospheric radioactivity can be characterized by concentrations of Cs-137, Be-7. The results show that concentrations of Cs-137 are 3 and the concentrations for Be-7 vary from 0.7 to 15.7 mBq/m 3 . Other important radionuclides are Sr-90, Uranium and Ra-226

  3. a Baseline Study of Physico-Chemical Parameters and Trace Metals in Waters of Manakudy, South-West Coast of India

    Science.gov (United States)

    Subramanian, M.; Muthumanikkam, J.

    2013-05-01

    The transport of trace metals from the land to ocean has a number of different routes and efficiencies. The sources of toxic elements into the rivers to be debouched into the sea through estuaries are either weathered naturally from the soils and rocks or introduced anthropogenically from point or non-point sources, in labile form or in particulate form. However, recent studies indicate that the transport of trace elements to the aquatic environment is much more complex than what has been thought. The chemistry and ecology of an estuarine system are entirely different from the fluvial as well as the marine system. Estuarine environment is characterized by a constantly changing mixture of salt and freshwater. In the present study area Manakudy estuary is situated about 8 kilometres north west of Kanyakumari (Latitude N 08 05 21.8 and Longitude E 077 29 03.7). To gain a better understanding of the geochemical behavior of physico-chemical parameters and trace elements in the estuary and to examine variations in associated chemical changes, 20 water samples were collected throughout the Manakudy estuary, a minor river in south-western India. These samples, collected in typical dry season during 2012, were analyzed for physico-chemical parameters, dissolved major and trace elements. Our results show that dissolved Na, Mg, Ca and Cl behave conservatively along the salinity gradient. The concentration of nutrients is normal and they are due to the higher organic activity in soils as well as faster rates of chemical weathering reaction in the source region. The concentration of major ions is due to tidal influence and it increases with salinity and the nutrients do behave non-conservatively due to biogenic removal. The conservative behaviour of the trace metals with salinity has been strongly affected by the introduction of these metals by external sources. Even though the trace metals in the contaminated water have been removed and incorporated in sediments due to

  4. Ultrafast electron diffraction using an ultracold source

    Directory of Open Access Journals (Sweden)

    M. W. van Mourik

    2014-05-01

    Full Text Available The study of structural dynamics of complex macromolecular crystals using electrons requires bunches of sufficient coherence and charge. We present diffraction patterns from graphite, obtained with bunches from an ultracold electron source, based on femtosecond near-threshold photoionization of a laser-cooled atomic gas. By varying the photoionization wavelength, we change the effective source temperature from 300 K to 10 K, resulting in a concomitant change in the width of the diffraction peaks, which is consistent with independently measured source parameters. This constitutes a direct measurement of the beam coherence of this ultracold source and confirms its suitability for protein crystal diffraction.

  5. Study on performance of a simultaneous spectrometer of ICP emission source for the determination of the major elements in rocks

    International Nuclear Information System (INIS)

    Vieira, M.D.

    1987-01-01

    The optimization of operational parameters of a simultaneous spectrometer coupled to an ICP excitation source in order to establish an analytical method for the simultaneous determination of the major elements in rocks is studied. The mutual spectral interferences, calibration curves for the acid and saline matrix and the internal standard method with ytrium are analyzed. (M.J.C.) [pt

  6. The superconducting x-ray lithography source program at Brookhaven

    Energy Technology Data Exchange (ETDEWEB)

    Williams, G. P.; Heese, R. N.; Vignola, G.; Murphy, J. B.; Godel, J. B.; Hsieh, H.; Galayda, J.; Seifert, A.; Knotek, M. L.

    1989-07-01

    A compact electron storage ring with superconducting dipole magnets, is being developed at the National Synchrotron Light Source at Brookhaven. The parameters of the source have been optimized for its future use as an x-ray source for lithography. This first ring is a prototype which will be used to study the operating characteristics of machines of this type with particular attention being paid to low-energy injection and long beam lifetime.

  7. Parameter studies for a two-component fusion experiment

    International Nuclear Information System (INIS)

    Towner, H.H.

    1975-01-01

    The sensitivity of the energy multiplication of a two-component fusion experiment is examined relative to the following parameters: energy confinement time (tau/sub E/), particle confinement time (tau/sub p/), effective Z of the plasma (Z/sub eff/), injection rate (j/sub I/) and injection energy (E/sub I/). The Energy Research and Development Administration recently approved funding for such a fusion device (the Toroidal Fusion Test Reactor or TFTR) which will be built at the Princeton Plasma Physics Laboratory. Hence, such a parameter study seems both timely and necessary. This work also serves as an independent check on the design values proposed for the TFTR to enable it to achieve energy breakeven (F = 1). Using the nominal TFTR design parameters and a self-consistent ion-electron power balance, the maximum F-value is found to be approximately 1.2 which occurs at an injection energy of approximately 210 KeV. The injector operation, i.e. its current and energy capability are shown to be a very critical factor in the TFTR performance. However, if the injectors meet the design objectives, there appears to be sufficient latitude in the other parameters to offer reasonable assurance that energy breakeven can be achieved. (U.S.)

  8. Analysis of Selected Physicochemical Parameters of Soils Used for ...

    African Journals Online (AJOL)

    Correlation analysis was also employed to examine the relationship between the various parameters in the soil samples. The soil studied can be considered as good sources of essential nutrients and this information will help farmers to solve the problems related to soil nutrients, amount of which fertilizers to be used to ...

  9. Parameter study on infilled steel frames with discretely connected precast concrete panels

    NARCIS (Netherlands)

    Teeuwen, P.A.; Kleinman, C.S.; Snijder, H.H.; Hofmeyer, H.; Chan, S.L.

    2009-01-01

    This paper presents a parameter study on infilled steel frames with discretely connected precast concrete infill panels having window openings. In this study, finite element simulations were carried out to study the infilled frame performance by varying several parameters. A recently developed

  10. Radio frequency glow discharge source with integrated voltage and current probes used for evaluation of discharge parameters

    International Nuclear Information System (INIS)

    Wilken, L.; Hoffmann, V.; Wetzig, K.

    2006-01-01

    A radio frequency (rf) Grimm-type glow discharge source for the chemical analysis of solid samples, with integrated voltage and current probes, was developed. All elements of a plasma equivalent circuit are determined from the measured current-voltage characteristics. The procedure is based on the independent evaluation of the ion current and electron current region. The physical meaning of the parameters is investigated by comparisons with measurements from dc glow discharges. We found that the reduced rf current of the powered electrode is comparable to the reduced current in dc discharges. A formula is developed that corrects the reduced current due to gas heating. The sheath thickness at the powered rf electrode is evaluated and is between 75 and 1100 μm. The voltage of the bulk plasma is in the range 2-15 V, and the resistance is between 30 and 400 Ω. The bulk plasma consumes about 3% of the total power, and the reduced voltage is comparable to the reduced electrical field in the positive column of direct current discharges. The sheath voltage at the grounded electrode is in the range 25-100 V, the capacities are between 10 and 400 pF, and the resistances are in the range 100 Ω-5000 Ω. We also found invariants for the evaluated sheath parameters

  11. Performance improvement of optical semiconductor sources

    International Nuclear Information System (INIS)

    El Tokhy, M.E.M.E

    2009-01-01

    This thesis has been concerned with a detailed study of nano-technology quantum sources. From these sources, quantum cascaded laser (QCLs) and quantum dot lasers (QDs), are studied theoretically. Block diagram models based on VisSim environment in junction with mathematical models are developed to analyze these kinds of optical sources. The mathematical model is derived to express explicitly the performance of the device, while a block diagram model is implemented which implicitly describe the same device. By using these mathematical models, new expressions are obtained. Accurate and efficient modeling of these sources is being increasingly important in the design and optimization of optical integrated circuits and circuit component. In the case of QCLs, the diagram is used to calculate its characteristics such as potential voltage, output optical power, current, threshold current density, slope efficiency, differential efficiency, and optical gain of these devices. Furthermore, the effect of each parameter of the QCLs, such as number of periods; N p , operating temperature; T, waveguide losses; α w , mirror losses; α m , on its performance are discussed in details. To demonstrate these effects further, the changes in three dimensional are plotted. In another mean, improving the lasing properties of the QCLs through both block diagram and mathematical models is the main scope in this thesis. In order to enhance the performance of the underlined device, mathematical model parameters are tuned to obtain the optimum behavior. Additionally, it is important to model and analyze the effects of these physical parameters on the performance of QCLs. These parameters play the central role in specifying the optical characteristics of the considered laser source. Proposed relation that linked emitted power with QCLs parameters is deduced. Moreover, it is important to have a large amount of radiated power, where increasing the amount of radiated power represents the main

  12. Linac Coherent Light Source (LCLS) design study report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 {angstrom}. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues.

  13. Linac Coherent Light Source (LCLS) design study report

    International Nuclear Information System (INIS)

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 angstrom. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues

  14. Study of non-metallic inclusion sources in steel

    International Nuclear Information System (INIS)

    Khons, Ya.; Mrazek, L.

    1976-01-01

    A study of potential inclusion sources was carried out at the Tvinec steel plant using an unified labelling procedure for different sources. A lanthanum oxide labelling method has been used for refractories with the subsequent La determination in steel by the neutron activation analysis. Samarium and cerium oxides and the 141 Ce radionuclide have been used in conjunction with the testing. The following sources of exogenous inclusions have been studied: 1)Refractory material comprising fireclay and corundum for steel-teeming trough in open-heart furnaces; 2) Fireclay bottom-pouring refractories; 3) Steel-teeming laddle lining; 4) Heat-insulating and exothermic compounds for steel ingots; 5) Vacuum treatment plant lining; 6) Open-hearth and electric arc furnace slag. The major oxide inclusion source in steel was found to be represented by the furnace slag, since it forms about 40 p.c. of all oxide inclusions. The contributions of the remaining sources did not exceede 5 p.c. each

  15. Exploratory Study for Continuous-time Parameter Estimation of Ankle Dynamics

    Science.gov (United States)

    Kukreja, Sunil L.; Boyle, Richard D.

    2014-01-01

    Recently, a parallel pathway model to describe ankle dynamics was proposed. This model provides a relationship between ankle angle and net ankle torque as the sum of a linear and nonlinear contribution. A technique to identify parameters of this model in discrete-time has been developed. However, these parameters are a nonlinear combination of the continuous-time physiology, making insight into the underlying physiology impossible. The stable and accurate estimation of continuous-time parameters is critical for accurate disease modeling, clinical diagnosis, robotic control strategies, development of optimal exercise protocols for longterm space exploration, sports medicine, etc. This paper explores the development of a system identification technique to estimate the continuous-time parameters of ankle dynamics. The effectiveness of this approach is assessed via simulation of a continuous-time model of ankle dynamics with typical parameters found in clinical studies. The results show that although this technique improves estimates, it does not provide robust estimates of continuous-time parameters of ankle dynamics. Due to this we conclude that alternative modeling strategies and more advanced estimation techniques be considered for future work.

  16. Dynamic Parameter Identification of Subject-Specific Body Segment Parameters Using Robotics Formalism: Case Study Head Complex.

    Science.gov (United States)

    Díaz-Rodríguez, Miguel; Valera, Angel; Page, Alvaro; Besa, Antonio; Mata, Vicente

    2016-05-01

    Accurate knowledge of body segment inertia parameters (BSIP) improves the assessment of dynamic analysis based on biomechanical models, which is of paramount importance in fields such as sport activities or impact crash test. Early approaches for BSIP identification rely on the experiments conducted on cadavers or through imaging techniques conducted on living subjects. Recent approaches for BSIP identification rely on inverse dynamic modeling. However, most of the approaches are focused on the entire body, and verification of BSIP for dynamic analysis for distal segment or chain of segments, which has proven to be of significant importance in impact test studies, is rarely established. Previous studies have suggested that BSIP should be obtained by using subject-specific identification techniques. To this end, our paper develops a novel approach for estimating subject-specific BSIP based on static and dynamics identification models (SIM, DIM). We test the validity of SIM and DIM by comparing the results using parameters obtained from a regression model proposed by De Leva (1996, "Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230). Both SIM and DIM are developed considering robotics formalism. First, the static model allows the mass and center of gravity (COG) to be estimated. Second, the results from the static model are included in the dynamics equation allowing us to estimate the moment of inertia (MOI). As a case study, we applied the approach to evaluate the dynamics modeling of the head complex. Findings provide some insight into the validity not only of the proposed method but also of the application proposed by De Leva (1996, "Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230) for dynamic modeling of body segments.

  17. Measurement of the Acoustic Nonlinearity Parameter for Biological Media.

    Science.gov (United States)

    Cobb, Wesley Nelson

    In vitro measurements of the acoustic nonlinearity parameter are presented for several biological media. With these measurements it is possible to predict the distortion of a finite amplitude wave in biological tissues of current diagnostic and research interest. The measurement method is based on the finite amplitude distortion of a sine wave that is emmitted by a piston source. The growth of the second harmonic component of this wave is measured by a piston receiver which is coaxial with and has the same size as the source. The experimental measurements and theory are compared in order to determine the nonlinearity parameter. The density, sound speed, and attenuation for the medium are determined in order to make this comparison. The theory developed for this study accounts for the influence of both diffraction and attenuation on the experimental measurements. The effects of dispersion, tissue inhomogeneity and gas bubbles within the excised tissues are studied. To test the measurement method, experimental results are compared with established values for the nonlinearity parameter of distilled water, ethylene glycol and glycerol. The agreement between these values suggests that the measurement uncertainty is (+OR-) 5% for liquids and (+OR-) 10% for solid tissues. Measurements are presented for dog blood and bovine serum albumen as a function of concentration. The nonlinearity parameters for liver, kidney and spleen are reported for both human and canine tissues. The values for the fresh tissues displayed little variation (6.8 to 7.8). Measurements for fixed, normal and cirrhotic tissues indicated that the nonlinearity parameter does not depend strongly on pathology. However, the values for fixed tissues were somewhat higher than those of the fresh tissues.

  18. Electron capture detector based on a non-radioactive electron source: operating parameters vs. analytical performance

    Directory of Open Access Journals (Sweden)

    E. Bunert

    2017-12-01

    Full Text Available Gas chromatographs with electron capture detectors are widely used for the analysis of electron affine substances such as pesticides or chlorofluorocarbons. With detection limits in the low pptv range, electron capture detectors are the most sensitive detectors available for such compounds. Based on their operating principle, they require free electrons at atmospheric pressure, which are usually generated by a β− decay. However, the use of radioactive materials leads to regulatory restrictions regarding purchase, operation, and disposal. Here, we present a novel electron capture detector based on a non-radioactive electron source that shows similar detection limits compared to radioactive detectors but that is not subject to these limitations and offers further advantages such as adjustable electron densities and energies. In this work we show first experimental results using 1,1,2-trichloroethane and sevoflurane, and investigate the effect of several operating parameters on the analytical performance of this new non-radioactive electron capture detector (ECD.

  19. Monitoring of conditions inside gas aggregation cluster source during production of Ti/TiOx nanoparticles

    Science.gov (United States)

    Kousal, J.; Kolpaková, A.; Shelemin, A.; Kudrna, P.; Tichý, M.; Kylián, O.; Hanuš, J.; Choukourov, A.; Biederman, H.

    2017-10-01

    Gas aggregation sources are nowadays rather widely used in the research community for producing nanoparticles. However, the direct diagnostics of conditions inside the source are relatively scarce. In this work, we focused on monitoring the plasma parameters and the composition of the gas during the production of the TiOx nanoparticles. We studied the role of oxygen in the aggregation process and the influence of the presence of the particles on the plasma. The construction of the source allowed us to make a 2D map of the plasma parameters inside the source.

  20. Experimental investigations on the influence of the photocathode laser pulse parameters on the electron bunch quality in an RF-photoelectron source

    Energy Technology Data Exchange (ETDEWEB)

    Haenel, Marc

    2010-07-15

    Free Electron Lasers based on the SASE principle like the European XFEL require electron bunches having peak currents of several kiloamperes as well as very low transverse emittance. While high peak currents can be generated using longitudinal bunch compression techniques, the transverse emittance must have values as low as 1mmmrad already at the source. The development of electron sources fulfilling these demanding specifications is the goal of the Photo Injector Test Facility (PITZ) in DESY, Zeuthen site. The key component of a photoinjector is the electron gun cavity where the electrons bunches are generated and immediately accelerated. The extraction of the electrons is based on the photoelectric effect of the cathode which requires a laser system having special capabilities. In the first part of the thesis, measurements are presented which were performed to investigate whether the laser and the laser transport system fulfill these requirements. The second part of the thesis is dedicated to simulations as well as experimental studies on the impact of the temporal and spatial parameters of the laser pulses on the electron bunch quality. This influence is possible because the response time of the Cs{sub 2}Te photocathode is short compared to the laser pulse duration. Based on these investigations, suggestions for improvements are given and tolerances for the laser pulse properties are defined. (orig.)

  1. Experimental investigations on the influence of the photocathode laser pulse parameters on the electron bunch quality in an RF-photoelectron source

    International Nuclear Information System (INIS)

    Haenel, Marc

    2010-06-01

    Free Electron Lasers based on the SASE principle like the European XFEL require electron bunches having peak currents of several kiloamperes as well as very low transverse emittance. While high peak currents can be generated using longitudinal bunch compression techniques, the transverse emittance must have values as low as 1mmmrad already at the source. The development of electron sources fulfilling these demanding specifications is the goal of the Photo Injector Test Facility (PITZ) in DESY, Zeuthen site. The key component of a photoinjector is the electron gun cavity where the electrons bunches are generated and immediately accelerated. The extraction of the electrons is based on the photoelectric effect of the cathode which requires a laser system having special capabilities. In the first part of the thesis, measurements are presented which were performed to investigate whether the laser and the laser transport system fulfill these requirements. The second part of the thesis is dedicated to simulations as well as experimental studies on the impact of the temporal and spatial parameters of the laser pulses on the electron bunch quality. This influence is possible because the response time of the Cs 2 Te photocathode is short compared to the laser pulse duration. Based on these investigations, suggestions for improvements are given and tolerances for the laser pulse properties are defined. (orig.)

  2. Study and Optimization of Design Parameters in Water Loop Heat Pump Systems for Office Buildings in the Iberian Peninsula

    Directory of Open Access Journals (Sweden)

    Francisco Javier Fernández

    2017-11-01

    Full Text Available Water loop heat pump (WLHP air conditioning systems use heat pumps connected to a common water circuit to fulfill the energy demands of different thermal zones in a building. In this study, the energy consumption was analyzed for the air conditioning of an office building in the typical climate of four important cities of the Iberian Peninsula. The energy consumption of one water loop heat pump system was compared with a conventional water system. Two design parameters, the range in the control temperatures and the water loop thermal storage size, were tested. Energy redistribution is an important advantage of the WLHP system, but significant savings came from high efficiency parameters in the heat pumps and minor air flow rates in the cooling tower. The low thermal level in the water loop makes this technology appropriate to combine with renewable sources. Using natural gas as the thermal energy source, a mean decrease in CO2 emissions of 8.1% was reached. Simulations showed that the installation of big thermal storage tanks generated small energy savings. Besides, the total annual consumption in buildings with high internal loads can be reduced by keeping the water loop as cool as possible.

  3. Trading Time with Space - Development of subduction zone parameter database for a maximum magnitude correlation assessment

    Science.gov (United States)

    Schaefer, Andreas; Wenzel, Friedemann

    2017-04-01

    Subduction zones are generally the sources of the earthquakes with the highest magnitudes. Not only in Japan or Chile, but also in Pakistan, the Solomon Islands or for the Lesser Antilles, subduction zones pose a significant hazard for the people. To understand the behavior of subduction zones, especially to identify their capabilities to produce maximum magnitude earthquakes, various physical models have been developed leading to a large number of various datasets, e.g. from geodesy, geomagnetics, structural geology, etc. There have been various studies to utilize this data for the compilation of a subduction zone parameters database, but mostly concentrating on only the major zones. Here, we compile the largest dataset of subduction zone parameters both in parameter diversity but also in the number of considered subduction zones. In total, more than 70 individual sources have been assessed and the aforementioned parametric data have been combined with seismological data and many more sources have been compiled leading to more than 60 individual parameters. Not all parameters have been resolved for each zone, since the data completeness depends on the data availability and quality for each source. In addition, the 3D down-dip geometry of a majority of the subduction zones has been resolved using historical earthquake hypocenter data and centroid moment tensors where available and additionally compared and verified with results from previous studies. With such a database, a statistical study has been undertaken to identify not only correlations between those parameters to estimate a parametric driven way to identify potentials for maximum possible magnitudes, but also to identify similarities between the sources themselves. This identification of similarities leads to a classification system for subduction zones. Here, it could be expected if two sources share enough common characteristics, other characteristics of interest may be similar as well. This concept

  4. Multi-parameter full waveform inversion using Poisson

    KAUST Repository

    Oh, Juwon

    2016-07-21

    In multi-parameter full waveform inversion (FWI), the success of recovering each parameter is dependent on characteristics of the partial derivative wavefields (or virtual sources), which differ according to parameterisation. Elastic FWIs based on the two conventional parameterisations (one uses Lame constants and density; the other employs P- and S-wave velocities and density) have low resolution of gradients for P-wave velocities (or ). Limitations occur because the virtual sources for P-wave velocity or (one of the Lame constants) are related only to P-P diffracted waves, and generate isotropic explosions, which reduce the spatial resolution of the FWI for these parameters. To increase the spatial resolution, we propose a new parameterisation using P-wave velocity, Poisson\\'s ratio, and density for frequency-domain multi-parameter FWI for isotropic elastic media. By introducing Poisson\\'s ratio instead of S-wave velocity, the virtual source for the P-wave velocity generates P-S and S-S diffracted waves as well as P-P diffracted waves in the partial derivative wavefields for the P-wave velocity. Numerical examples of the cross-triangle-square (CTS) model indicate that the new parameterisation provides highly resolved descent directions for the P-wave velocity. Numerical examples of noise-free and noisy data synthesised for the elastic Marmousi-II model support the fact that the new parameterisation is more robust for noise than the two conventional parameterisations.

  5. A study of physics of sub-critical multiplicative systems driven by sources and the utilization of deterministic codes in calculation of this systems

    International Nuclear Information System (INIS)

    Antunes, Alberi

    2008-01-01

    This work presents the Physics of Source Driven Systems (ADS). It shows some statics and K i netics parameters of the reactor Physics and when it is sub critical, that are important in evaluation and definition of these systems. The objective is to demonstrate that there are differences in parameters when the reactor is critical. Moreover, the work shows the differences observed in the parameters for different calculation models. Two calculation methodologies are shown In this dissertation: Gandini and Salvatores and Dulla, and some parameters are calculated. The ANISN deterministic transport code is used in calculation in order to compare these parameters. In a subcritical configuration of IPEN-MB-01 Reactor driven by an external source some parameters are calculated. The conclusions about calculation realized are presented in end of work. (author)

  6. Recommendation of ruthenium source for sludge batch flowsheet studies

    Energy Technology Data Exchange (ETDEWEB)

    Woodham, W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-13

    Included herein is a preliminary analysis of previously-generated data from sludge batches 7a, 7b, 8, and 9 sludge simulant and real-waste testing, performed to recommend a form of ruthenium for future sludge batch simulant testing under the nitric-formic flowsheet. Focus is given to reactions present in the Sludge Receipt and Adjustment Tank cycle, given that this cycle historically produces the most changes in chemical composition during Chemical Process Cell processing. Data is presented and analyzed for several runs performed under the nitric-formic flowsheet, with consideration given to effects on the production of hydrogen gas, nitrous oxide gas, consumption of formate, conversion of nitrite to nitrate, and the removal and recovery of mercury during processing. Additionally, a brief discussion is given to the effect of ruthenium source selection under the nitric-glycolic flowsheet. An analysis of data generated from scaled demonstration testing, sludge batch 9 qualification testing, and antifoam degradation testing under the nitric-glycolic flowsheet is presented. Experimental parameters of interest under the nitric-glycolic flowsheet include N2O production, glycolate destruction, conversion of glycolate to formate and oxalate, and the conversion of nitrite to nitrate. To date, the number of real-waste experiments that have been performed under the nitric-glycolic flowsheet is insufficient to provide a complete understanding of the effects of ruthenium source selection in simulant experiments with regard to fidelity to real-waste testing. Therefore, a determination of comparability between the two ruthenium sources as employed under the nitric-glycolic flowsheet is made based on available data in order to inform ruthenium source selection for future testing under the nitric-glycolic flowsheet.

  7. Oyster Creek cycle 10 nodal model parameter optimization study using PSMS

    International Nuclear Information System (INIS)

    Dougher, J.D.

    1987-01-01

    The power shape monitoring system (PSMS) is an on-line core monitoring system that uses a three-dimensional nodal code (NODE-B) to perform nodal power calculations and compute thermal margins. The PSMS contains a parameter optimization function that improves the ability of NODE-B to accurately monitor core power distributions. This functions iterates on the model normalization parameters (albedos and mixing factors) to obtain the best agreement between predicted and measured traversing in-core probe (TIP) reading on a statepoint-by-statepoint basis. Following several statepoint optimization runs, an average set of optimized normalization parameters can be determined and can be implemented into the current or subsequent cycle core model for on-line core monitoring. A statistical analysis of 19 high-power steady-state state-points throughout Oyster Creek cycle 10 operation has shown a consistently poor virgin model performance. The normalization parameters used in the cycle 10 NODE-B model were based on a cycle 8 study, which evaluated only Exxon fuel types. The introduction of General Electric (GE) fuel into cycle 10 (172 assemblies) was a significant fuel/core design change that could have altered the optimum set of normalization parameters. Based on the need to evaluate a potential change in the model normalization parameters for cycle 11 and in an attempt to account for the poor cycle 10 model performance, a parameter optimization study was performed

  8. Added-value joint source modelling of seismic and geodetic data

    Science.gov (United States)

    Sudhaus, Henriette; Heimann, Sebastian; Walter, Thomas R.; Krueger, Frank

    2013-04-01

    In tectonically active regions earthquake source studies strongly support the analysis of the current faulting processes as they reveal the location and geometry of active faults, the average slip released or more. For source modelling of shallow, moderate to large earthquakes often a combination of geodetic (GPS, InSAR) and seismic data is used. A truly joint use of these data, however, usually takes place only on a higher modelling level, where some of the first-order characteristics (time, centroid location, fault orientation, moment) have been fixed already. These required basis model parameters have to be given, assumed or inferred in a previous, separate and highly non-linear modelling step using one of the these data sets alone. We present a new earthquake rupture model implementation that realizes a fully combined data integration of surface displacement measurements and seismic data in a non-linear optimization of simple but extended planar ruptures. The model implementation allows for fast forward calculations of full seismograms and surface deformation and therefore enables us to use Monte Carlo global search algorithms. Furthermore, we benefit from the complementary character of seismic and geodetic data, e. g. the high definition of the source location from geodetic data and the sensitivity of the resolution of the seismic data on moment releases at larger depth. These increased constraints from the combined dataset make optimizations efficient, even for larger model parameter spaces and with a very limited amount of a priori assumption on the source. A vital part of our approach is rigorous data weighting based on the empirically estimated data errors. We construct full data error variance-covariance matrices for geodetic data to account for correlated data noise and also weight the seismic data based on their signal-to-noise ratio. The estimation of the data errors and the fast forward modelling opens the door for Bayesian inferences of the source

  9. Source parameters of the swarm earthquakes in West Bohemia/Vogtland

    Czech Academy of Sciences Publication Activity Database

    Michálek, Jan; Fischer, Tomáš

    2013-01-01

    Roč. 195, č. 2 (2013), s. 1196-1210 ISSN 0956-540X Institutional support: RVO:67985530 Keywords : Fourier analysis * earthquake source observations * seismic ity and tectonics Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 2.724, year: 2013

  10. PM10 source apportionment study in Pleasant Valley, Nevada

    International Nuclear Information System (INIS)

    Egami, R.T.; Chow, J.C.; Watson, J.G.; DeLong, T.

    1990-01-01

    A source apportionment study was conducted between March 18 and April 4, 1988, at Pleasant Valley, Nevada, to evaluate air pollutant concentrations to which community residents were exposed and the source contributions to those pollutants. Daily PM 10 samples were taken for chemical speciation of 40 trace elements, ions, and organic and elemental carbon. This paper reports that the objectives of this case study are: to determine the emissions source composition of the potential upwind source, a geothermal plant; to measure the ambient particulate concentration and its chemical characteristics in Pleasant Valley; and to estimate the contributions of different emissions sources to PM 10 . The study found that: particulate emissions from the geothermal cooling-tower plume consisted primarily of sulfate, ammonia, chloride, and trace elements; no significant quantities of toxic inorganic species were found in the ambient air; ambient PM 10 concentrations in Pleasant Valley were within Federal standards; and source contribution to PM 10 were approximately 60% geological material; 20% motor vehicle exhaust; and 10% cooling-tower plume

  11. Ultraviolet germicidal efficacy as a function of pulsed radiation parameters studied by spore film dosimetry.

    Science.gov (United States)

    Bauer, Stefan; Holtschmidt, Hans; Ott, Günter

    2018-01-01

    Disinfection by pulsed ultraviolet (UV) radiation is a commonly used method, e.g. in industry or medicine and can be carried out either with lasers or broadband UV radiation sources. Detrimental effects to biological materials depending on parameters such as pulse duration τ or pulse repetition frequency f p are well-understood for pulsed coherent UV radiation, however, relatively little is known for its incoherent variant. Therefore, within this work, it is the first time that disinfection rates of pulsed and continuous (cw) incoherent UV radiation studied by means of spore film dosimetry are presented, compared with each other, and in a second step further investigated regarding two pulse parameters. After analyzing the dynamic range of the Bacillus subtilis spore films with variable cw radiant exposures H=5-100Jm -2 a validation of the Bunsen-Roscoe law revealed its restricted applicability and a 28% enhanced detrimental effect of pulsed compared to cw incoherent UV radiation. A radiant exposure H=50Jm -2 and an irradiance E=0.5Wm -2 were found to be suitable parameters for an analysis of the disinfection rate as a function of τ=0.5-10ms and f p =25-500Hz unveiling that shorter pulses and lower frequencies inactivate more spores. Finally, the number of applied pulses as well as the experiment time were considered with regard to spore film disinfection. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Study on characteristics of valves for pulsed gas feed into a cyclotron multicharged ion source

    International Nuclear Information System (INIS)

    Bogomolov, S.L.; Efremov, A.A.; Koval'chuk, I.M.; Kutner, V.B.; Pasyuk, A.S.

    1984-01-01

    Different valves (with rotating drum, piezoelectric and electromagnetic) for pulsed gas feed into cyclotron multicharged ion arc source are described. It is shown that piezoelectric and electromagnetic valves provide a possibility of regulating in a wide range the gas flow pulse parameters

  13. Parameter determination in a groundwater field polluted by radioactive pollutant

    International Nuclear Information System (INIS)

    Sidauruk, P.; Barokah A; Syafalni; Wibagiyo

    1998-01-01

    The determination of source location and the corresponding parameters in a contaminated groundwater is very important. To be able to predict the distribution of radioactive contaminant in a contaminated field, the knowledge about the source location and the corresponding parameters is a necessity. The model developed in this paper is based on the fact that the relation between the logarithm of the concentration of the radio active contaminant with the squared coordinate is linear. The contaminant transport parameters as well as the a straight line. In other words, the parameters and the source location are determined in a such way that the linear correlation coefficient between the logarithm of the concentration of the radio active contaminant with the squared coordinate is optimized. The developed model is tested with a synthetic data with a satisfactory results. The synthetic data is generated such that can represent the real field. The synthetic data are generated because the real field data is not available. (authors)

  14. Experimental study of electromagnetic radiation from a faster-than-light vacuum macroscopic source

    Energy Technology Data Exchange (ETDEWEB)

    Bessarab, A.V. [Russian Federal Nuclear Center-All-Russia Scientific Research Institute of Experimental Physics, Sarov, Nizhni Novgorod region, 607188 (Russian Federation); Martynenko, S.P. [Russian Federal Nuclear Center-All-Russia Scientific Research Institute of Experimental Physics, Sarov, Nizhni Novgorod region, 607188 (Russian Federation); Prudkoi, N.A. [Russian Federal Nuclear Center-All-Russia Scientific Research Institute of Experimental Physics, Sarov, Nizhni Novgorod region, 607188 (Russian Federation); Soldatov, A.V. [Russian Federal Nuclear Center-All-Russia Scientific Research Institute of Experimental Physics, Sarov, Nizhni Novgorod region, 607188 (Russian Federation)]. E-mail: soldatov@vniief.ru; Terekhin, V.A. [Russian Federal Nuclear Center-All-Russia Scientific Research Institute of Experimental Physics, Sarov, Nizhni Novgorod region, 607188 (Russian Federation)

    2006-08-15

    The effect which manifests itself in the form of directed electromagnetic pulses (EMP) initiated by an X-ray incident obliquely upon a conducting surface has been confirmed and investigated experimentally in detail. A planar accelerating diode comprising a metallic cathode and grid anode was initiated with an oblique short soft-X-ray pulse from a point laser-plasma source. Then a source of directed EMP-a current of accelerated photoelectrons-was formed whose boundary ran along the anode external surface with a faster-than-light velocity. The plasma was formed when short-pulse ({approx}0.3ns) laser radiation from ISKRA-5 facility was focused on a plane Au target. The amplitude-in-time and spatial characteristics of radiation emitted by the faster-than-light source have been measured. Parameters of the accelerated electron current have been measured too.

  15. POPULATION SYNTHESIS OF HOT SUBDWARFS: A PARAMETER STUDY

    International Nuclear Information System (INIS)

    Clausen, Drew; Wade, Richard A.; Kopparapu, Ravi Kumar; O'Shaughnessy, Richard

    2012-01-01

    Binaries that contain a hot subdwarf (sdB) star and a main-sequence companion may have interacted in the past. This binary population has historically helped determine our understanding of binary stellar evolution. We have computed a grid of binary population synthesis models using different assumptions about the minimum core mass for helium ignition, the envelope binding energy, the common-envelope ejection efficiency, the amount of mass and angular momentum lost during stable mass transfer, and the criteria for stable mass transfer on the red giant branch and in the Hertzsprung gap. These parameters separately and together can significantly change the entire predicted population of sdBs. Nonetheless, several different parameter sets can reproduce the observed subpopulation of sdB + white dwarf and sdB + M dwarf binaries, which has been used to constrain these parameters in previous studies. The period distribution of sdB + early F dwarf binaries offers a better test of different mass transfer scenarios for stars that fill their Roche lobes on the red giant branch.

  16. Source and ground-motion parameters of the 2011 Lorca earthquake; Parametros de la fuente y del movimiento del suelo del terremoto de Lorca de 2011

    Energy Technology Data Exchange (ETDEWEB)

    Alguacil de la Blanca, G.; Vidal Sanchez, F.; Stich, D.; Mancilla Perez, F. L.; Lopez Comino, J. A.; Morales Soto, J.; Navarro Bernal, M.

    2012-07-01

    113 events of the Lorca seismic series has been relocated by using Double difference algorithm and data from both temporary and permanent seismic networks. Relocations yield shallow hypo central distribution of aftershocks with a {approx}5 km long, NE-SW trending, placed SW of the mainshock, suggesting a SW propagating rupture along the Alhama de Murcia fault. Similar oblique reverse faulting mechanism has been obtained for three largest events. Source parameters of these three earthquakes have been estimated. Horizontal ground motion was estimated at 11 city points whose local structure was known by SPAC experiments. A set of ground motion parameters (PGA, PGV, AI, CAV, SI, SA and SV) here calculated, have higher values at these points respect to the ones at LOR station. All parameter values are also above the expected values for Euro -Mediterranean earthquakes with local intensity VIII (EMS). Nevertheless, SD values are unusually short and less than the reference ones. Higher values of the response spectra of acceleration and velocity are given for periods of less than 0.7 s, with maximum spectral acceleration at 0.15 s and velocity at 0.5 s. The elastic input energy spectrum is well connected to the shake destructiveness in each place. Equivalent velocity > 60 cm/s is found in almost all sites and > 100 cm/s (for periods 0.3 to 0.6 s) in someone. Factors such as proximity, and focal mechanism and ground response characteristics explain the high ground motion parameter values obtained in Lorca sites and show the great influence of the source and site conditions on the characteristics of strong ground motion in the vicinity of the rupture. (Author) 68 refs.

  17. Prospects of renewable energy sources in India: Prioritization of alternative sources in terms of Energy Index

    International Nuclear Information System (INIS)

    Jha, Shibani K.; Puppala, Harish

    2017-01-01

    The growing energy demand in progressing civilization governs the exploitation of various renewable sources over the conventional sources. Wind, Solar, Hydro, Biomass, and waste & Bagasse are the various available renewable sources in India. A reliable nonconventional geothermal source is also available in India but it is restricted to direct heat applications. This study archives the status of renewable alternatives in India. The techno economic factors and environmental aspects associated with each of these alternatives are discussed. This study focusses on prioritizing the renewable sources based on a parameter introduced as Energy Index. This index is evaluated using cumulative scores obtained for each of the alternatives. The cumulative score is obtained by evaluating each alternative over a range of eleven environmental and techno economic criteria following Fuzzy Analytical Hierarchy Process. The eleven criteria's considered in the study are Carbon dioxide emissions (CO 2 ), Sulphur dioxide emissions (SO 2 ), Nitrogen oxide emissions (NO x ), Land requirement, Current energy cost, Potential future energy cost, Turnkey investment, Capacity factor, Energy efficiency, Design period and Water consumption. It is concluded from the study that the geothermal source is the most preferable alternative with highest Energy Index. Hydro, Wind, Biomass and Solar sources are subsequently preferred alternatives. - Highlights: • FAH process is used to obtain cumulative score for each renewable alternative. • Cumulative score is normalized by highest score of ideal source. • Energy Index shows how best a renewable alternative is. • Priority order is obtained for alternatives based on Energy Index. • Geothermal is most preferable source followed by Hydro, Wind, Biomass and Solar.

  18. Cost-effectiveness modeling for neuropathic pain treatments: investigating the relative importance of parameters using an open-source model.

    Science.gov (United States)

    Hirst, Matthew; Bending, Matthew W; Baio, Gianluca; Yesufu-Udechuku, Amina; Dunlop, William C N

    2018-06-08

    The study objective was to develop an open-source replicate of a cost-effectiveness model developed by National Institute for Health and Care (NICE) in order to explore uncertainties in health economic modeling of novel pharmacological neuropathic pain treatments. The NICE model, consisting of a decision tree with branches for discrete levels of pain relief and adverse event (AE) severities, was replicated using R and used to compare a hypothetical neuropathic pain drug to pregabalin. Model parameters were sourced from NICE's clinical guidelines and associated with probability distributions to account for underlying uncertainty. A simulation-based scenario analysis was conducted to assess how uncertainty in efficacy and AEs affected the net monetary benefit (NMB) for the hypothetical treatment at a cost-effectiveness threshold of £20,000 per QALY. Relative to pregabalin, an increase in efficacy was associated with greater NMB than an improvement in tolerability. A greater NMB was observed when efficacy was marginally higher than that of pregabalin while maintaining the same level of AEs than when efficacy was equivalent to pregabalin but with a more substantial reduction in AEs. In the latter scenario, the NMB was only positive at a low cost-effectiveness threshold. The replicate model shares the limitations described in the NICE guidelines. There is a lack of support in scientific literature for the assumption that increased efficacy is associated with a greater reduction in tolerability. The replicate model also included a single comparator, unlike the NICE model. Pain relief is a stronger driver of NMB than tolerability at a cost-effectiveness threshold of £20,000 per QALY. Health technology assessment decisions which are influenced by NICE's model may reward efficacy gains even if they are associated with more severe AEs. This contrasts with recommendations from clinical guidelines for neuropathic pain which place more equal weighting on improvements in

  19. Assessing FPAR Source and Parameter Optimization Scheme in Application of a Diagnostic Carbon Flux Model

    Energy Technology Data Exchange (ETDEWEB)

    Turner, D P; Ritts, W D; Wharton, S; Thomas, C; Monson, R; Black, T A

    2009-02-26

    The combination of satellite remote sensing and carbon cycle models provides an opportunity for regional to global scale monitoring of terrestrial gross primary production, ecosystem respiration, and net ecosystem production. FPAR (the fraction of photosynthetically active radiation absorbed by the plant canopy) is a critical input to diagnostic models, however little is known about the relative effectiveness of FPAR products from different satellite sensors nor about the sensitivity of flux estimates to different parameterization approaches. In this study, we used multiyear observations of carbon flux at four eddy covariance flux tower sites within the conifer biome to evaluate these factors. FPAR products from the MODIS and SeaWiFS sensors, and the effects of single site vs. cross-site parameter optimization were tested with the CFLUX model. The SeaWiFs FPAR product showed greater dynamic range across sites and resulted in slightly reduced flux estimation errors relative to the MODIS product when using cross-site optimization. With site-specific parameter optimization, the flux model was effective in capturing seasonal and interannual variation in the carbon fluxes at these sites. The cross-site prediction errors were lower when using parameters from a cross-site optimization compared to parameter sets from optimization at single sites. These results support the practice of multisite optimization within a biome for parameterization of diagnostic carbon flux models.

  20. Boundary Layer Fluid Flow in a Channel with Heat Source, Soret ...

    African Journals Online (AJOL)

    The boundary layer fluid flow in a channel with heat source, soret effects and slip condition was studied. The governing equations were solved using perturbation technique. The effects of different parameters such Prandtl number Pr , Hartmann number M, Schmidt number Sc, suction parameter ƒÜ , soret number Sr and the ...

  1. Desert plains classification based on Geomorphometrical parameters (Case study: Aghda, Yazd)

    Science.gov (United States)

    Tazeh, mahdi; Kalantari, Saeideh

    2013-04-01

    This research focuses on plains. There are several tremendous methods and classification which presented for plain classification. One of The natural resource based classification which is mostly using in Iran, classified plains into three types, Erosional Pediment, Denudation Pediment Aggradational Piedmont. The qualitative and quantitative factors to differentiate them from each other are also used appropriately. In this study effective Geomorphometrical parameters in differentiate landforms were applied for plain. Geomorphometrical parameters are calculable and can be extracted using mathematical equations and the corresponding relations on digital elevation model. Geomorphometrical parameters used in this study included Percent of Slope, Plan Curvature, Profile Curvature, Minimum Curvature, the Maximum Curvature, Cross sectional Curvature, Longitudinal Curvature and Gaussian Curvature. The results indicated that the most important affecting Geomorphometrical parameters for plain and desert classifications includes: Percent of Slope, Minimum Curvature, Profile Curvature, and Longitudinal Curvature. Key Words: Plain, Geomorphometry, Classification, Biophysical, Yazd Khezarabad.

  2. Studies and modeling of cold neutron sources; Etude et modelisation des sources froides de neutron

    Energy Technology Data Exchange (ETDEWEB)

    Campioni, G

    2004-11-15

    With the purpose of updating knowledge in the fields of cold neutron sources, the work of this thesis has been run according to the 3 following axes. First, the gathering of specific information forming the materials of this work. This set of knowledge covers the following fields: cold neutron, cross-sections for the different cold moderators, flux slowing down, different measurements of the cold flux and finally, issues in the thermal analysis of the problem. Secondly, the study and development of suitable computation tools. After an analysis of the problem, several tools have been planed, implemented and tested in the 3-dimensional radiation transport code Tripoli-4. In particular, a module of uncoupling, integrated in the official version of Tripoli-4, can perform Monte-Carlo parametric studies with a spare factor of Cpu time fetching 50 times. A module of coupling, simulating neutron guides, has also been developed and implemented in the Monte-Carlo code McStas. Thirdly, achieving a complete study for the validation of the installed calculation chain. These studies focus on 3 cold sources currently functioning: SP1 from Orphee reactor and 2 other sources (SFH and SFV) from the HFR at the Laue Langevin Institute. These studies give examples of problems and methods for the design of future cold sources.

  3. GLOBAL SOURCING: A THEORETICAL STUDY ON TURKEY

    Directory of Open Access Journals (Sweden)

    Aytac GOKMEN

    2010-07-01

    Full Text Available Global sourcing is to source from the global market for goods and services across national boundaries in order to take advantage of the global efficiencies in the delivery of a product or service. Such efficiencies are consists of low cost skilled labor, low cost raw materials and other economic factors like tax breaks and deductions as well as low trade tariffs. When we assess the case regarding to Turkey, global sourcing is an effective device for some firms. The domestic firms in Turkey at various industries are inclined to global source finished or intermediate goods from the world markets, finish the production process in Turkey and export. Eventually, on the one hand the export volume of Turkey increases, but on the other hand the import of a considerable volume of finished or intermediate goods bring about a negative trade balance and loss of jobs in Turkey. Therefore, the objective of this study is to assess the concept of global sourcing transactions on Turkey resting on comprehensive publications.

  4. Nuclear Criticality Technology and Safety Project parameter study database

    International Nuclear Information System (INIS)

    Toffer, H.; Erickson, D.G.; Samuel, T.J.; Pearson, J.S.

    1993-03-01

    A computerized, knowledge-screened, comprehensive database of the nuclear criticality safety documentation has been assembled as part of the Nuclear Criticality Technology and Safety (NCTS) Project. The database is focused on nuclear criticality parameter studies. The database has been computerized using dBASE III Plus and can be used on a personal computer or a workstation. More than 1300 documents have been reviewed by nuclear criticality specialists over the last 5 years to produce over 800 database entries. Nuclear criticality specialists will be able to access the database and retrieve information about topical parameter studies, authors, and chronology. The database places the accumulated knowledge in the nuclear criticality area over the last 50 years at the fingertips of a criticality analyst

  5. Production of multicharged radioactive ion beams for spiral: studies and realization of the first target-ion source system

    International Nuclear Information System (INIS)

    Maunoury, L.

    1998-01-01

    In the framework of the SPIRAL project, which concerns the production and the acceleration of a multicharged radioactive ions beam, the following part has been studied: production and ionization of the radioactive ions beam. A first target-source (nanogan II), devoted exclusively to the production of multicharged radioactive ions gas type beams, has been studied and tested. The diffusion efficiency has been deduced from the diffusion equations (Fick laws). This efficiency is governed by the following parameters: the temperature, the grains size of the target, the Arrhenius parameters and the radioactive period. Another study concerning the production targets is presented. It deals with the temperature distribution allowing an utilization of more than one month at a temperature of 2400 K. Another development (SPIRAL II) is devoted to the production of high neutron content radioactive atoms created by the uranium fission, from fast neutrons. The neutrons beam is produced by the ''stripping break-up'' of a deutons beam in a converter. (A.L.B.)

  6. Source parameters estimation of 2003 Bam earthquake Mw 6.5 ...

    Indian Academy of Sciences (India)

    to optimize the fit to observed elastic response spectra. .... Sources of uncertainty in engineering safety prob- .... be created and passed to their children. Without an operator of this type, some possibly important regions of the search space may never be explored. ..... mization, and machine learning (Reading, MA: Addison-.

  7. Studying Regional Wave Source Time Functions Using the Empirical Green's Function Method: Application to Central Asia

    Science.gov (United States)

    Xie, J.; Schaff, D. P.; Chen, Y.; Schult, F.

    2013-12-01

    Reliably estimated source time functions (STFs) from high-frequency regional waveforms, such as Lg, Pn and Pg, provide important input for seismic source studies, explosion detection and discrimination, and minimization of parameter trade-off in attenuation studies. We have searched for candidate pairs of larger and small earthquakes in and around China that share the same focal mechanism but significantly differ in magnitudes, so that the empirical Green's function (EGF) method can be applied to study the STFs of the larger events. We conducted about a million deconvolutions using waveforms from 925 earthquakes, and screened the deconvolved traces to exclude those that are from event pairs that involved different mechanisms. Only 2,700 traces passed this screening and could be further analyzed using the EGF method. We have developed a series of codes for speeding up the final EGF analysis by implementing automations and user-graphic interface procedures. The codes have been fully tested with a subset of screened data and we are currently applying them to all the screened data. We will present a large number of deconvolved STFs retrieved using various phases (Lg, Pn, Sn and Pg and coda) with information on any directivities, any possible dependence of pulse durations on the wave types, on scaling relations for the pulse durations and event sizes, and on the estimated source static stress drops.

  8. Magnetic characteristics of industrial dust from different sources of emission: A case study of Poland

    Science.gov (United States)

    Szuszkiewicz, Marcin; Magiera, Tadeusz; Kapička, Aleš; Petrovský, Eduard; Grison, Hanna; Gołuchowska, Beata

    2015-05-01

    Dust emission and deposition in topsoil have negative effect on individual components of the ecosystem. In addition to routine geochemical analyses, magnetic measurements may provide useful complementary information related to the type, concentration and grain-size distribution of the technogenic magnetic particles (TMPs) and thus the degree of contamination of the environment. The aim of this contribution is to use magnetic parameters in distinguishing dust from a wide range of sources of air pollution (power industry, cement, coke, ceramic industries and biomass combustion). We measured magnetic susceptibility, hysteresis parameters and thermomagnetic curves. Our results suggest that predominant component in tested samples is magnetite, only dust from coking plant and the combustion of lignite contained also maghemite and/or hematite. Mixture of sizes, ranging from fine single-domain to coarse multi-domain grains, was detected. Our results indicate that industrial dusts from various sources of emissions have different specific magnetic properties and magnetic measurements may provide very helpful information.

  9. Study on bulk shielding for a spallation neutron source facility in the high-intensity proton accelerator project

    CERN Document Server

    Maekawa, F; Takada, H; Teshigawara, M; Watanabe, N

    2002-01-01

    Under the JAERI-KEK High-Intensity Proton Accelerator Project, a spallation neutron source driven by a 3 GeV-1 MW proton beam is planed to be constructed in a main part of the Materials and Life Science Facility. This report describes results of a study on bulk shielding performance of a biological shield for the spallation neutron source by means of a Monte Carlo calculation method, that is important in terms of radiation safety and cost reduction. A shielding configuration was determined as a reference case by considering preliminary studies and interaction with other components, then shielding thickness that was required to achieve a target dose rate of 1 mu Sv/h was derived. Effects of calculation conditions such as shielding materials and dimensions on the shielding performance was investigated by changing those parameters. By taking all the results and design margins into account, a shielding configuration that was identified as the most appropriate was finally determined as follows. An iron shield regi...

  10. A System for Extracting Study Design Parameters from Nutritional Genomics Abstracts

    Directory of Open Access Journals (Sweden)

    Kelly Cassidy

    2013-06-01

    Full Text Available The extraction of study design parameters from biomedical journal articles is an important problem in natural language processing (NLP. Such parameters define the characteristics of a study, such as the duration, the number of subjects, and their profile. Here we present a system for extracting study design parameters from sentences in article abstracts. This system will be used as a component of a larger system for creating nutrigenomics networks from articles in the nutritional genomics domain. The algorithms presented consist of manually designed rules expressed either as regular expressions or in terms of sentence parse structure. A number of filters and NLP tools are also utilized within a pipelined algorithmic framework. Using this novel approach, our system performs extraction at a finer level of granularity than comparable systems, while generating results that surpass the current state of the art.

  11. A New Method for Determining Optimal Regularization Parameter in Near-Field Acoustic Holography

    Directory of Open Access Journals (Sweden)

    Yue Xiao

    2018-01-01

    Full Text Available Tikhonov regularization method is effective in stabilizing reconstruction process of the near-field acoustic holography (NAH based on the equivalent source method (ESM, and the selection of the optimal regularization parameter is a key problem that determines the regularization effect. In this work, a new method for determining the optimal regularization parameter is proposed. The transfer matrix relating the source strengths of the equivalent sources to the measured pressures on the hologram surface is augmented by adding a fictitious point source with zero strength. The minimization of the norm of this fictitious point source strength is as the criterion for choosing the optimal regularization parameter since the reconstructed value should tend to zero. The original inverse problem in calculating the source strengths is converted into a univariate optimization problem which is solved by a one-dimensional search technique. Two numerical simulations with a point driven simply supported plate and a pulsating sphere are investigated to validate the performance of the proposed method by comparison with the L-curve method. The results demonstrate that the proposed method can determine the regularization parameter correctly and effectively for the reconstruction in NAH.

  12. Sustainability in Open Source Software Commons: Lessons Learned from an Empirical Study of SourceForge Projects

    Directory of Open Access Journals (Sweden)

    Charles M. Schweik

    2013-01-01

    Full Text Available In this article, we summarize a five-year US National Science Foundation funded study designed to investigate the factors that lead some open source projects to ongoing collaborative success while many others become abandoned. Our primary interest was to conduct a study that was closely representative of the population of open source software projects in the world, rather than focus on the more-often studied, high-profile successful cases. After building a large database of projects (n=174,333 and implementing a major survey of open source developers (n=1403, we were able to conduct statistical analyses to investigate over forty theoretically-based testable hypotheses. Our data firmly support what we call the conventional theory of open source software, showing that projects start small, and, in successful cases, grow slightly larger in terms of team size. We describe the “virtuous circle” supporting conventional wisdom of open source collaboration that comes out of this analysis, and we discuss two other interesting findings related to developer motivations and how team members find each other. Each of these findings is related to the sustainability of these projects.

  13. The Source Inversion Validation (SIV) Initiative: A Collaborative Study on Uncertainty Quantification in Earthquake Source Inversions

    Science.gov (United States)

    Mai, P. M.; Schorlemmer, D.; Page, M.

    2012-04-01

    Earthquake source inversions image the spatio-temporal rupture evolution on one or more fault planes using seismic and/or geodetic data. Such studies are critically important for earthquake seismology in general, and for advancing seismic hazard analysis in particular, as they reveal earthquake source complexity and help (i) to investigate earthquake mechanics; (ii) to develop spontaneous dynamic rupture models; (iii) to build models for generating rupture realizations for ground-motion simulations. In applications (i - iii), the underlying finite-fault source models are regarded as "data" (input information), but their uncertainties are essentially unknown. After all, source models are obtained from solving an inherently ill-posed inverse problem to which many a priori assumptions and uncertain observations are applied. The Source Inversion Validation (SIV) project is a collaborative effort to better understand the variability between rupture models for a single earthquake (as manifested in the finite-source rupture model database) and to develop robust uncertainty quantification for earthquake source inversions. The SIV project highlights the need to develop a long-standing and rigorous testing platform to examine the current state-of-the-art in earthquake source inversion, and to develop and test novel source inversion approaches. We will review the current status of the SIV project, and report the findings and conclusions of the recent workshops. We will briefly discuss several source-inversion methods, how they treat uncertainties in data, and assess the posterior model uncertainty. Case studies include initial forward-modeling tests on Green's function calculations, and inversion results for synthetic data from spontaneous dynamic crack-like strike-slip earthquake on steeply dipping fault, embedded in a layered crustal velocity-density structure.

  14. Experimental Study of the Performance of Air Source Heat Pump Systems Assisted by Low-Temperature Solar-Heated Water

    Directory of Open Access Journals (Sweden)

    Jinshun Wu

    2013-01-01

    Full Text Available Due to the low temperatures, the heating efficiency of air source heat pump systems during the winter is very low. To address this problem, a low-temperature solar hot water system was added to a basic air source heat pump system. Several parameters were tested and analyzed. The heat collection efficiency of the solar collector was analyzed under low-temperature conditions. The factors that affect the performance of the heat pumps, such as the fluid temperature, pressure, and energy savings, were analyzed for cases where the solar energy auxiliary heat pump and the air source heat pump are used independently. The optimal heating temperature and the changes in the fluid temperature were determined. The influence of the compression ratio and the coefficient of performance (COP were investigated theoretically. The results revealed the parameters that are important to the performance of the system. Several measures for improving the COP of the heat pump units are provided for other applications and future research.

  15. Efficient source for the production of ultradense deuterium D(-1) for laser-induced fusion (ICF)

    International Nuclear Information System (INIS)

    Andersson, Patrik U.; Loenn, Benny; Holmlid, Leif

    2011-01-01

    A novel source which simplifies the study of ultradense deuterium D(-1) is now described. This means one step further toward deuterium fusion energy production. The source uses internal gas feed and D(-1) can now be studied without time-of-flight spectral overlap from the related dense phase D(1). The main aim here is to understand the material production parameters, and thus a relatively weak laser with focused intensity ≤10 12 W cm -2 is employed for analyzing the D(-1) material. The properties of the D(-1) material at the source are studied as a function of laser focus position outside the emitter, deuterium gas feed, laser pulse repetition frequency and laser power, and temperature of the source. These parameters influence the D(-1) cluster size, the ionization mode, and the laser fragmentation patterns.

  16. Efficient source for the production of ultradense deuterium D(-1) for laser-induced fusion (ICF)

    Science.gov (United States)

    Andersson, Patrik U.; Lönn, Benny; Holmlid, Leif

    2011-01-01

    A novel source which simplifies the study of ultradense deuterium D(-1) is now described. This means one step further toward deuterium fusion energy production. The source uses internal gas feed and D(-1) can now be studied without time-of-flight spectral overlap from the related dense phase D(1). The main aim here is to understand the material production parameters, and thus a relatively weak laser with focused intensity ≤1012 W cm-2 is employed for analyzing the D(-1) material. The properties of the D(-1) material at the source are studied as a function of laser focus position outside the emitter, deuterium gas feed, laser pulse repetition frequency and laser power, and temperature of the source. These parameters influence the D(-1) cluster size, the ionization mode, and the laser fragmentation patterns.

  17. Sealed source and device removal and consolidation feasibility study

    International Nuclear Information System (INIS)

    Ward, J.E.; Carter, J.G.; Meyers, R.L.

    1993-02-01

    The purpose of this study is to assess the feasibility of removing Greater-Than-Class C (GTCC) sealed sources from their containment device and consolidating them for transport to a storage or disposal facility. A sealed source is a sealed capsule containing a radioactive material that is placed in a device providing radioactive containment. It is used in the medical, industrial, research, and food-processing communities for calibrating, measuring, gauging, controlling processes, and testing. This feasibility study addresses the key operational, safety, regulatory, and financial requirements of the removal/consolidation process. This report discusses the process to receive, handle, repackage, and ship these sources to an interim or dedicated storage facility until a final disposal repository can be built and become operational (∼ c. 2010). The study identifies operational and facility requirements to perform this work. Hanford, other DOE facilities, and private hot-cell facilities were evaluated to determine which facilities could perform this work. The personnel needed, design and engineering, facility preparation, process waste disposal requirements, and regulatory compliance were evaluated to determine the cost to perform this work. Cost requirements for items that will have to meet future changing regulatory requirements for transportation, transportation container design and engineering, and disposal were not included in this study. The cost associated with in-process consolidation of the sealed sources reported in this study may have not been modified for inflation and were based on 1992 dollars. This study shows that sealed source consolidation is possible with minimal personnel exposure, and would reduce the risk of radioactive releases to the environment. An initial pilot-scale operation could evaluate the possible methods to reduce the cost and consolidate sources

  18. Efficient Bayesian experimental design for contaminant source identification

    Science.gov (United States)

    Zhang, Jiangjiang; Zeng, Lingzao; Chen, Cheng; Chen, Dingjiang; Wu, Laosheng

    2015-01-01

    In this study, an efficient full Bayesian approach is developed for the optimal sampling well location design and source parameters identification of groundwater contaminants. An information measure, i.e., the relative entropy, is employed to quantify the information gain from concentration measurements in identifying unknown parameters. In this approach, the sampling locations that give the maximum expected relative entropy are selected as the optimal design. After the sampling locations are determined, a Bayesian approach based on Markov Chain Monte Carlo (MCMC) is used to estimate unknown parameters. In both the design and estimation, the contaminant transport equation is required to be solved many times to evaluate the likelihood. To reduce the computational burden, an interpolation method based on the adaptive sparse grid is utilized to construct a surrogate for the contaminant transport equation. The approximated likelihood can be evaluated directly from the surrogate, which greatly accelerates the design and estimation process. The accuracy and efficiency of our approach are demonstrated through numerical case studies. It is shown that the methods can be used to assist in both single sampling location and monitoring network design for contaminant source identifications in groundwater.

  19. Advanced Neutron Source Cross Section Libraries (ANSL-V): ENDF/B-V based multigroup cross-section libraries for advanced neutron source (ANS) reactor studies

    International Nuclear Information System (INIS)

    Ford, W.E. III; Arwood, J.W.; Greene, N.M.; Moses, D.L.; Petrie, L.M.; Primm, R.T. III; Slater, C.O.; Westfall, R.M.; Wright, R.Q.

    1990-09-01

    Pseudo-problem-independent, multigroup cross-section libraries were generated to support Advanced Neutron Source (ANS) Reactor design studies. The ANS is a proposed reactor which would be fueled with highly enriched uranium and cooled with heavy water. The libraries, designated ANSL-V (Advanced Neutron Source Cross Section Libraries based on ENDF/B-V), are data bases in AMPX master format for subsequent generation of problem-dependent cross-sections for use with codes such as KENO, ANISN, XSDRNPM, VENTURE, DOT, DORT, TORT, and MORSE. Included in ANSL-V are 99-group and 39-group neutron, 39-neutron-group 44-gamma-ray-group secondary gamma-ray production (SGRP), 44-group gamma-ray interaction (GRI), and coupled, 39-neutron group 44-gamma-ray group (CNG) cross-section libraries. The neutron and SGRP libraries were generated primarily from ENDF/B-V data; the GRI library was generated from DLC-99/HUGO data, which is recognized as the ENDF/B-V photon interaction data. Modules from the AMPX and NJOY systems were used to process the multigroup data. Validity of selected data from the fine- and broad-group neutron libraries was satisfactorily tested in performance parameter calculations

  20. Using Indirect Turbulence Measurements for Real-Time Parameter Estimation in Turbulent Air

    Science.gov (United States)

    Martos, Borja; Morelli, Eugene A.

    2012-01-01

    The use of indirect turbulence measurements for real-time estimation of parameters in a linear longitudinal dynamics model in atmospheric turbulence was studied. It is shown that measuring the atmospheric turbulence makes it possible to treat the turbulence as a measured explanatory variable in the parameter estimation problem. Commercial off-the-shelf sensors were researched and evaluated, then compared to air data booms. Sources of colored noise in the explanatory variables resulting from typical turbulence measurement techniques were identified and studied. A major source of colored noise in the explanatory variables was identified as frequency dependent upwash and time delay. The resulting upwash and time delay corrections were analyzed and compared to previous time shift dynamic modeling research. Simulation data as well as flight test data in atmospheric turbulence were used to verify the time delay behavior. Recommendations are given for follow on flight research and instrumentation.

  1. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  2. Salivary caries parameters: Comparative study among Yemeni khat chewers and nonchewers

    OpenAIRE

    Khaled Rashad Al-Alimi; Abdul Aziz Abdul Razak; Roslan Saub

    2014-01-01

    Background/purpose: Millions of people in Yemen and East African countries chew khat for more than 5 hours daily for its amphetamine-like effects. Previous studies have associated khat chewing with salivary glands enlargement, inflammation, and xerostomia. However, no information is available on the possible effects of this habit on salivary parameters. This comparative study aims to evaluate salivary parameters, such as salivary flow rate, pH, and viscosity among Yemeni khat chewers and nonc...

  3. Empirical relations between instrumental and seismic parameters of some strong earthquakes of Colombia

    International Nuclear Information System (INIS)

    Marin Arias, Juan Pablo; Salcedo Hurtado, Elkin de Jesus; Castillo Gonzalez, Hardany

    2008-01-01

    In order to establish the relationships between macroseismic and instrumental parameters, macroseismic field of 28 historical earthquakes that produced great effects in the Colombian territory were studied. The integration of the parameters was made by using the methodology of Kaussel and Ramirez (1992), for great Chilean earthquakes; Kanamori and Anderson (1975) and Coppersmith and Well (1994) for world-wide earthquakes. Once determined the macroseismic and instrumental parameters it was come to establish the model of the source of each earthquake, with which the data base of these parameters was completed. For each earthquake parameters related to the local and normal macroseismic epicenter were complemented, depth of the local and normal center, horizontal extension of both centers, vertical extension of the normal center, model of the source, area of rupture. The obtained empirical relations from linear equations, even show behaviors very similar to the found ones by other authors for other regions of the world and to world-wide level. The results of this work allow establishing that certain mutual non compatibility exists between the area of rupture and the length of rupture determined by the macroseismic methods, with parameters found with instrumental data like seismic moment, Ms magnitude and Mw magnitude.

  4. Antenatal surveillance through estimates of the sources underlying the abdominal phonogram: a preliminary study

    International Nuclear Information System (INIS)

    Jiménez-González, A; James, C J

    2013-01-01

    Today, it is generally accepted that current methods for biophysical antenatal surveillance do not facilitate a comprehensive and reliable assessment of foetal well-being and that continuing research into alternative methods is necessary to improve antenatal monitoring procedures. In our research, attention has been paid to the abdominal phonogram, a signal that is recorded by positioning an acoustic sensor on the maternal womb and contains valuable information about foetal status, but which is hidden by maternal and environmental sources. To recover such information, previous work has used single-channel independent component analysis (SCICA) on the abdominal phonogram and successfully retrieved estimates of the foetal phonocardiogram, the maternal phonocardiogram, the maternal respirogram and noise. The availability of these estimates made it possible for the current study to focus on their evaluation as sources for antenatal surveillance purposes. To this end, the foetal heart rate (FHR), the foetal heart sounds morphology, the maternal heart rate (MHR) and the maternal breathing rate (MBR) were collected from the estimates retrieved from a dataset of 25 abdominal phonograms. Next, these parameters were compared with reference values to quantify the significance of the physiological information extracted from the estimates. As a result, it has been seen that the instantaneous FHR, the instantaneous MHR and the MBR collected from the estimates consistently followed the trends given by the reference signals, which is a promising outcome for this preliminary study. Thus, as far as this study has gone, it can be said that the independent traces retrieved by SCICA from the abdominal phonogram are likely to become valuable sources of information for well-being surveillance, both foetal and maternal. (paper)

  5. Noise study of all-normal dispersion supercontinuum sources for potential application in optical coherence tomography

    Science.gov (United States)

    Gonzalo, I. B.; Engelsholm, R. D.; Bang, O.

    2018-03-01

    Commercially available silica-fiber-based and ultra-broadband supercontinuum (SC) sources are typically generated by pumping close to the zero-dispersion wavelength (ZDW) of a photonic crystal fiber (PCF), using high-power picosecond or nanosecond laser pulses. Despite the extremely broad bandwidths, such sources are characterized by large intensity fluctuations, limiting their performance for applications in imaging such as optical coherence tomography (OCT). An approach to eliminate the influence of noise sensitive effects is to use a so-called all-normal dispersion (ANDi) fiber, in which the dispersion is normal for all the wavelengths of interest. Pumping these types of fibers with short enough femtosecond pulses allows to suppress stimulated Raman scattering (SRS), which is known to be as noisy process as modulation instability (MI), and coherent SC is generated through self-phase modulation (SPM) and optical wave breaking (OWB). In this study, we show the importance of the pump laser and fiber parameters in the design of low-noise ANDi based SC sources, for application in OCT. We numerically investigate the pulse-to-pulse fluctuations of the SC, calculating the relative intensity noise (RIN) as a function of the pump pulse duration and fiber length. Furthermore, we experimentally demonstrate the role of the fiber length on the RIN of the ANDi SC, validating the results calculated numerically. In the end, we compare the RIN of a commercial SC source based on MI and the ANDi SC source developed here, which shows better noise performance when it is carefully designed.

  6. [Study of the plantar arch: correlations between podometrical and radiological parameters. results of a prospective study of 79 cases].

    Science.gov (United States)

    Maes, R; Dojcinovic, S; Andrianne, Y; Burny, F

    2006-01-01

    The authors present a prospective study on the potential correlations between eight footprint parameters and three radiological parameters in the study of the plantar arch. Seventy nine patients were evaluated in 2001. The eight footprint parameters were as fellows : the arch angle, the Chippaux-Smirak's index, the Quamra's contact index 2,3 and 4, the Schwartz's footprint angle, the Staheli's arch index and the arch length index. The three radiological parameters were as fellows : the Djian-Annonier's angle, the Méary's angle and the calcaneal inclination. This prospective study confirms the best correlation, found in others studies, obtained between the Djian-Annonier's angle and the Chippaux-Smirak. The use of the Méary's angle and the calcaneal inclination is not justified because they have bad correlations with footprint parameters.

  7. A Study on the Pyrolysis of Peanut Shells at Different Isothermal Conditions and Determination of the Kinetic Parameters

    Directory of Open Access Journals (Sweden)

    Şeyda Taşar

    2015-12-01

    Full Text Available The pyrolysis process, which is applied for the aim of producing energy and raw materials which are implemented for the chemical industry from biomass sources, is a thermal conversion process. Determination of the pyrolysis kinetic parameters are important In order to suitable equipment and process design. In this target, in the study the pyrolysis of peanut shells was conducted in a muffle furnace at static atmosphere with temperatures ranging from 300-700 °C. The effects of various parameters on the rate of thermal decomposition rate and the solid yield were determined. The parameters of interest were temperature 300-700 °C, particle size 4-50 mesh, pelletizing, and pelletizing pressure 1.103-5.103 kgf/cm2. Regression coefficients for the total decomposition step were obtained using the thermographs were obtained as a result of the pyrolysis of the peanut shells, and 20 different theoretical model equations that represented the degradation by the Coast-Redfern method. According to regression coefficients of the theoretical model equations, we determined the kinetic model that best represented the degradation. Using this model to represent the degradation, the activation energy (Ea and Arhenius frequency factor ln(A for the total reaction were calculated to be 38.245 kJ/mol and 8.124, respectively.

  8. SPOTting model parameters using a ready-made Python package

    Science.gov (United States)

    Houska, Tobias; Kraft, Philipp; Breuer, Lutz

    2015-04-01

    The selection and parameterization of reliable process descriptions in ecological modelling is driven by several uncertainties. The procedure is highly dependent on various criteria, like the used algorithm, the likelihood function selected and the definition of the prior parameter distributions. A wide variety of tools have been developed in the past decades to optimize parameters. Some of the tools are closed source. Due to this, the choice for a specific parameter estimation method is sometimes more dependent on its availability than the performance. A toolbox with a large set of methods can support users in deciding about the most suitable method. Further, it enables to test and compare different methods. We developed the SPOT (Statistical Parameter Optimization Tool), an open source python package containing a comprehensive set of modules, to analyze and optimize parameters of (environmental) models. SPOT comes along with a selected set of algorithms for parameter optimization and uncertainty analyses (Monte Carlo, MC; Latin Hypercube Sampling, LHS; Maximum Likelihood, MLE; Markov Chain Monte Carlo, MCMC; Scuffled Complex Evolution, SCE-UA; Differential Evolution Markov Chain, DE-MCZ), together with several likelihood functions (Bias, (log-) Nash-Sutcliff model efficiency, Correlation Coefficient, Coefficient of Determination, Covariance, (Decomposed-, Relative-, Root-) Mean Squared Error, Mean Absolute Error, Agreement Index) and prior distributions (Binomial, Chi-Square, Dirichlet, Exponential, Laplace, (log-, multivariate-) Normal, Pareto, Poisson, Cauchy, Uniform, Weibull) to sample from. The model-independent structure makes it suitable to analyze a wide range of applications. We apply all algorithms of the SPOT package in three different case studies. Firstly, we investigate the response of the Rosenbrock function, where the MLE algorithm shows its strengths. Secondly, we study the Griewank function, which has a challenging response surface for

  9. Neutronics of pulsed spallation neutron sources

    International Nuclear Information System (INIS)

    Watanabe, Noboru

    2003-01-01

    Various topics and issues on the neutronics of pulsed spallation neutron sources, mainly for neutron scattering experiments, are reviewed to give a wide circle of readers a better understanding of these sources in order to achieve a high neutronic performance. Starting from what neutrons are needed, what the spallation reaction is and how to produce slow-neutrons more efficiently, the outline of the target and moderator neutronics are explained. Various efforts with some new concepts or ideas have already been devoted to obtaining the highest possible slow-neutron intensity with desired pulse characteristics. This paper also reviews the recent progress of such efforts, mainly focused on moderator neutronics, since moderators are the final devices of a neutron source, which determine the source performance. Various governing parameters for neutron-pulse characteristics such as material issues, geometrical parameters (shape and dimensions), the target-moderator coupling scheme, the ortho-para-hydrogen ratio, poisoning, etc are discussed, aiming at a high performance pulsed spallation source

  10. Nordic working group on CCF studies. Parameter estimation within the activities of the Nordic CCF Group

    International Nuclear Information System (INIS)

    Johansson, G.

    2002-01-01

    This is a presentation of a project programme for assessment of CCF events and adoption of international data derived in the ICDE project to conditions in Sweden and Finland. The overall objective with the working group is to: - Support safety by studying potential and real CCF events and report conclusions and recommendations that can improve the understanding of these events eventually resulting in increased safety; - The result is intended for application in NPP operation, maintenance, inspection and risk assessments. The work is divided into one quantitative and one qualitative part with the following specific objectives: Qualitative objectives: Compile experiences data and generate insights in terms of relevant failure mechanisms and effective CCF protection measures. The results shall be presented as a guide with checklists and recommendations on how to identify current CCF protection standard and improvement possibilities regarding CCF defenses decreasing the CCF vulnerability. Quantitative objectives: Prepare a Nordic C-book where quantitative insights as Impact Vectors and CCF parameters for different redundancy levels are presented. Uncertainties in CCF data shall be reduced as much as possible. The high redundancy systems sensitivity to CCF events demand a well structured quantitative analysis in support of best possible and realistic CCF parameter estimates, if possible, plant specific. Model survey and review: This survey shah examine available models and their applicability for use on the data. Several models exist and are used in the Nordic PSAs. Data survey and review: This survey shall examine available data sources and their applicability. The survey shah review ICDE and other sources and Provide a background for the decision on what data to be used. A possible outcome is of course that the ICDE data are shown to cover all other sources, but there are possibilities the ICDE data shall be combined with some other source. The situation also differs

  11. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors

    Science.gov (United States)

    Nashy, El-Shahat H. A.; Al-Ashkar, Emad; Abdel Moez, A.

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows.

  12. New Insights on the Uncertainties in Finite-Fault Earthquake Source Inversion

    KAUST Repository

    Razafindrakoto, Hoby

    2015-04-01

    New Insights on the Uncertainties in Finite-Fault Earthquake Source Inversion Hoby Njara Tendrisoa Razafindrakoto Earthquake source inversion is a non-linear problem that leads to non-unique solutions. The aim of this dissertation is to understand the uncertainty and reliability in earthquake source inversion, as well as to quantify variability in earthquake rupture models. The source inversion is performed using a Bayesian inference. This technique augments optimization approaches through its ability to image the entire solution space which is consistent with the data and prior information. In this study, the uncertainty related to the choice of source-time function and crustal structure is investigated. Three predefined analytical source-time functions are analyzed; isosceles triangle, Yoffe with acceleration time of 0.1 and 0.3 s. The use of the isosceles triangle as source-time function is found to bias the finite-fault source inversion results. It accelerates the rupture to propagate faster compared to that of the Yoffe function. Moreover, it generates an artificial linear correlation between parameters that does not exist for the Yoffe source-time functions. The effect of inadequate knowledge of Earth’s crustal structure in earthquake rupture models is subsequently investigated. The results show that one-dimensional structure variability leads to parameters resolution changes, with a broadening of the posterior 5 PDFs and shifts in the peak location. These changes in the PDFs of kinematic parameters are associated with the blurring effect of using incorrect Earth structure. As an application to real earthquake, finite-fault source models for the 2009 L’Aquila earthquake are examined using one- and three-dimensional crustal structures. One- dimensional structure is found to degrade the data fitting. However, there is no significant effect on the rupture parameters aside from differences in the spatial slip extension. Stable features are maintained for both

  13. 22 Na positron source for annihilation positron spectroscopy

    International Nuclear Information System (INIS)

    Cimpeanu, Catalina; Craciun, Liviu; Dragulescu, Emilian; Dudu, Dorin; Racolta, Petre Mihai; Voiculescu, Dana; Miron, N.

    2005-01-01

    To extend the nuclear physics applications and to perform the study of vacancy - type defects in metals, semiconductors, polymers, etc., we developed new positron annihilation techniques. In line with this goal we started a project for production of positron sources at the IFIN-HH U-120 Cyclotron. We made use of the nuclear reaction: 24 Mg(d,α) 22 Na with deuterons of 13 MeV energy. The paper present the main steps of this procedure which are: establishing the conditions required for 22 NaCl sources, for the parameters of reaction chamber and the characteristics of Mg target, parameters for the irradiation, radiochemical procedures for separation of Na from Mg after irradiation as well as the geometrical and mechanical requirements for the NaCl source. In the e + lifetime measurements the e + 'stop' signals are always provided by gamma - quanta generated by the e + e - annihilation and the 'start' signals are obtained from 'prompt' gamma - quanta emitted by the NaCl source (1.275 MeV photons). The 22 NaCl stock solution obtained by radiochemical separation will be kept in quartz sealed ampoules. (authors)

  14. Study of a microwave power source for a two-beam accelerator

    International Nuclear Information System (INIS)

    Houck, T.L.

    1994-01-01

    A theoretical and experimental study of a microwave power source suitable for driving a linear e + e - collider is reported. The power source is based on the Relativistic Klystron Two-Beam Accelerator (RK-TBA) concept, is driven by a 5-MeV, 1-kA induction accelerator electron beam, and operates at X-band frequencies. The development of a computer code to simulate the transverse beam dynamics of an intense relativistic electron beam transiting a system of microwave resonant structures is presented. This code is time dependent with self-consistent beam-cavity interactions and uses realistic beam parameters. Simulations performed with this code are compared with analytical theory and experiments. The concept of spacing resonant structures at distances equal to the betatron wavelength of the focusing system to suppress the growth of transverse instabilities is discussed. Simulations include energy spread over the beam to demonstrate the effect of Landau damping and establish the sensitivity of the betatron wavelength spacing scheme to errors in the focusing system. The design of the Reacceleration Experiment is described in detail and includes essentially all the issues related to a full scale RK-TBA microwave source. A total combined power from three output structures in excess of 170 MW with an amplitude stability of ±4% over a 25 ns pulse was achieved. The results of the experiment are compared to simulations used during the design phase to validate the various codes and methods used. The primary issue for the RK-TBA concept is identified as transverse beam instability associated with the excitation of higher order modes in the resonant structures used for extracting microwave power from the modulated beam. This work represents the first successful experimental demonstration of repeated cycles of microwave energy extraction from and reacceleration of a modulated beam

  15. Measurement of radon flux and tailings parameters for quantifying the source term due to radon exhalation from U tailings pile at Jaduguda

    International Nuclear Information System (INIS)

    Sahoo, B.K.; Mayya, Y.S.; Sapra, B.K.; Gaware, J.J.; Khuswaha, H.S.

    2010-01-01

    Full text: The exposures from radon ( 222 Rn) and its decay products have been received considerable attention in the world community because of their adverse health effect. There are various natural and man-made sources of radon present in our environment. Among the man-made sources, the U tailings (waste product from U mining and milling facility) may be considered an important one because it contains significant amount of 226 Ra activity after the U extraction from the ore bodies. These tailings (slurry form) are being impounded into a repository site nearby the facility called 'Tailings Pile' (TP). Significant amount of radon emission takes place from this area by the process of emanation and exhalation. Hence, a study was taken up to quantify the source term arising due to radon emission from uranium tailings pile at Jaduguda in Jharkhand state. In-situ experiments were conducted at 40 locations of the uranium tailings pile in three seasons namely summer, rainy and winter to measure the radon fluxes. The measurements were carried out by deploying a cylindrical chamber, attached to a continuous radon monitor, on the surface of the tailings pile. The dimension of the chamber was selected by using a recently developed two dimensional theory of soil chamber, so that radon concentration growth will be in exponential fashion and the data generated within 2-3 hours of deployment period will be sufficient for accurately deriving the actual radon flux. After the data collection, the fluxes were derived by fitting an exponential growth function to the plot of radon concentration with time. The fluxes were also predicted by diffusion theory using the measured tailings parameters such as 226 Ra content, radon emanation factor, porosity, temperature and moisture. An excellent matching between the predicted and measured fluxes was observed. The validity of diffusion theory in the matrix of U tailings pile provides an alternate method for back-calculating the tailings

  16. Sleep Parameters in Short Daily versus Conventional Dialysis: An Actigraphic Study

    Directory of Open Access Journals (Sweden)

    Ludimila D’Avila e Silva Allemand

    2017-01-01

    Full Text Available Previous studies have observed worse sleep quality in patients undergoing conventional dialysis as compared to daily dialysis. Our aim was to compare the sleep parameters of patients undergoing daily or conventional dialysis using an objective measure (actigraphy. This cross-sectional study was performed in three dialysis centers, including a convenience sample (nonprobability sampling of 73 patients (36 patients on daily hemodialysis and 37 patients on conventional hemodialysis. The following parameters were evaluated: nocturnal total sleep time (NTST, expressed in minutes; wake time after sleep onset (WASO, expressed in minutes; number of nighttime awakenings; daytime total sleep time (DTST, expressed in minutes; number of daytime naps; and nighttime percentage of sleep (% sleep. The Mini-Mental State Examination and the Beck Depression Inventory were also administered. The mean age was 53.4  ±  17.0 years. After adjustment of confounding factors using multiple linear regression analysis, no difference in actigraphy parameters was detected between the groups: NTST (p=0.468, WASO (p=0.88, % sleep (p=0.754, awakenings (p=0.648, naps (p=0.414, and DTST (p=0.805. Different from previous studies employing qualitative analysis, the present assessment did not observe an influence of hemodialysis modality on objective sleep parameters in chronic renal patients.

  17. Emotion impairs extrinsic source memory--An ERP study.

    Science.gov (United States)

    Mao, Xinrui; You, Yuqi; Li, Wen; Guo, Chunyan

    2015-09-01

    Substantial advancements in understanding emotional modulation of item memory notwithstanding, controversies remain as to how emotion influences source memory. Using an emotional extrinsic source memory paradigm combined with remember/know judgments and two key event-related potentials (ERPs)-the FN400 (a frontal potential at 300-500 ms related to familiarity) and the LPC (a later parietal potential at 500-700 ms related to recollection), our research investigated the impact of emotion on extrinsic source memory and the underlying processes. We varied a semantic prompt (either "people" or "scene") preceding a study item to manipulate the extrinsic source. Behavioral data indicated a significant effect of emotion on "remember" responses to extrinsic source details, suggesting impaired recollection-based source memory in emotional (both positive and negative) relative to neutral conditions. In parallel, differential FN400 and LPC amplitudes (correctly remembered - incorrectly remembered sources) revealed emotion-related interference, suggesting impaired familiarity and recollection memory of extrinsic sources associated with positive or negative items. These findings thus lend support to the notion of emotion-induced memory trade off: while enhancing memory of central items and intrinsic/integral source details, emotion nevertheless disrupts memory of peripheral contextual details, potentially impairing both familiarity and recollection. Importantly, that positive and negative items result in comparable memory impairment suggests that arousal (vs. affective valence) plays a critical role in modulating dynamic interactions among automatic and elaborate processes involved in memory. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Parameters of importance to determine in geoscientific site studies

    International Nuclear Information System (INIS)

    Andersson, Johan; Almen, K.E.; Ericsson, L.O.; Karlsson, Fred; Stroem, A.; Fredriksson, Anders; Stanfors, R.

    1996-12-01

    This report identifies and describes parameters, that may be determined in a site characterization study, for performing functional and safety analyses of a deep rock repository for radioactive wastes. The report discusses data needs for rock engineering and for description of other environmental aspects. It is intended that the report be used as a basis for formulating the criteria of acceptance in evaluating a candidate site. The report describes how different parameters influence the safety function, and how they are evaluated in practice. The logical order of performing measurements, due to the need of in-data and influence on other measurements is also discussed. 65 refs

  19. Sustainability in Open Source Software Commons: Lessons Learned from an Empirical Study of SourceForge Projects

    OpenAIRE

    Charles M. Schweik

    2013-01-01

    In this article, we summarize a five-year US National Science Foundation funded study designed to investigate the factors that lead some open source projects to ongoing collaborative success while many others become abandoned. Our primary interest was to conduct a study that was closely representative of the population of open source software projects in the world, rather than focus on the more-often studied, high-profile successful cases. After building a large database of projects (n=174,33...

  20. Thermal Hydraulic design parameters study for severe accidents using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Chang Hyun; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Chang, Keun Sun [Sunmoon University, Asan (Korea, Republic of)

    1998-12-31

    To provide the information on severe accident progression is very important for advanced or new type of nuclear power plant (NPP) design. A parametric study, therefore, was performed to investigate the effect of thermal hydraulic design parameters on severe accident progression of pressurized water reactors (PWRs). Nine parameters, which are considered important in NPP design or severe accident progression, were selected among the various thermal hydraulic design parameters. The backpropagation neural network (BPN) was used to determine parameters, which might more strongly affect the severe accident progression, among nine parameters. For training, different input patterns were generated by the latin hypercube sampling (LHS) technique and then different target patterns that contain core uncovery time and vessel failure time were obtained for Young Gwang Nuclear (YGN) Units 3 and 4 using modular accident analysis program (MAAP) 3.0B code. Three different severe accident scenarios, such as two loss of coolant accidents (LOCAs) and station blackout (SBO), were considered in this analysis. Results indicated that design parameters related to refueling water storage tank (RWST), accumulator and steam generator (S/G) have more dominant effects on the progression of severe accidents investigated, compared to the other six parameters. 9 refs., 5 tabs. (Author)

  1. Thermal Hydraulic design parameters study for severe accidents using neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Chang Hyun; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Chang, Keun Sun [Sunmoon University, Asan (Korea, Republic of)

    1997-12-31

    To provide the information on severe accident progression is very important for advanced or new type of nuclear power plant (NPP) design. A parametric study, therefore, was performed to investigate the effect of thermal hydraulic design parameters on severe accident progression of pressurized water reactors (PWRs). Nine parameters, which are considered important in NPP design or severe accident progression, were selected among the various thermal hydraulic design parameters. The backpropagation neural network (BPN) was used to determine parameters, which might more strongly affect the severe accident progression, among nine parameters. For training, different input patterns were generated by the latin hypercube sampling (LHS) technique and then different target patterns that contain core uncovery time and vessel failure time were obtained for Young Gwang Nuclear (YGN) Units 3 and 4 using modular accident analysis program (MAAP) 3.0B code. Three different severe accident scenarios, such as two loss of coolant accidents (LOCAs) and station blackout (SBO), were considered in this analysis. Results indicated that design parameters related to refueling water storage tank (RWST), accumulator and steam generator (S/G) have more dominant effects on the progression of severe accidents investigated, compared to the other six parameters. 9 refs., 5 tabs. (Author)

  2. Total grain-size distribution of four subplinian-Plinian tephras from Hekla volcano, Iceland: Implications for sedimentation dynamics and eruption source parameters

    Science.gov (United States)

    Janebo, Maria H.; Houghton, Bruce F.; Thordarson, Thorvaldur; Bonadonna, Costanza; Carey, Rebecca J.

    2018-05-01

    The size distribution of the population of particles injected into the atmosphere during a volcanic explosive eruption, i.e., the total grain-size distribution (TGSD), can provide important insights into fragmentation efficiency and is a fundamental source parameter for models of tephra dispersal and sedimentation. Recent volcanic crisis (e.g. Eyjafjallajökull 2010, Iceland and Córdon Caulle 2011, Chile) and the ensuing economic losses, highlighted the need for a better constraint of eruption source parameters to be used in real-time forecasting of ash dispersal (e.g., mass eruption rate, plume height, particle features), with a special focus on the scarcity of published TGSD in the scientific literature. Here we present TGSD data associated with Hekla volcano, which has been very active in the last few thousands of years and is located on critical aviation routes. In particular, we have reconstructed the TGSD of the initial subplinian-Plinian phases of four historical eruptions, covering a range of magma composition (andesite to rhyolite), eruption intensity (VEI 4 to 5), and erupted volume (0.2 to 1 km3). All four eruptions have bimodal TGSDs with mass fraction of fine ash (primary fragmentation. Due to differences in plume height, this contrast is not seen in samples from individual sites, especially in the near field, where lapilli have a wider spatial coverage in the Plinian deposits. The distribution of pyroclast sizes in Plinian versus subplinian falls reflects competing influences of more efficient fragmentation (e.g., producing larger amounts of fine ash) versus more efficient particle transport related to higher and more vigorous plumes, displacing relatively coarse lapilli farther down the dispersal axis.

  3. Studying the influence of strong meteorological disturbances in the Earth's lower atmosphere on variations of ionospheric parameters in the Asian region of Russia

    Science.gov (United States)

    Chernigovskaya, Marina; Kurkin, Vladimir; Orlov, Igor; Oinats, Alexey; Sharkov, Eugenii

    2010-05-01

    Short-period temporal variations of ionospheric parameters were analyzed to study probabilities of manifestation of strong meteorological disturbances in the Earth's lower atmosphere in variations of upper atmosphere parameters in a zone far removed from a disturbance source. In the analysis, we used data on maximum observed frequencies (MOF) of oblique sounding (OS) signals along Norilsk-Irkutsk, Magadan-Irkutsk, and Khabarovsk-Irkutsk paths in East Siberia and the Far East. These data were obtained during solar minimum at equinoxes (March, September) in 2008-2009. Analyzing effects of wave disturbances in ionospheric parameters, we take into account helio-geomagnetic and meteorological conditions in regions under study to do an effective separation between disturbances associated with magnetospheric-ionospheric coupling and those induced by the influence of the lower atmosphere on the upper one. The frequency analysis we conducted revealed time intervals with higher intensity of short-period oscillations which may have been interpreted as manifestation of large-scale traveling ionospheric disturbances (TIDs) whose sources were internal gravity waves (IGWs) with periods of 1-5 hours. The complex analysis of helio-geomagnetic, ionospheric, and atmospheric data as well as data on tropical cyclones established that the detected TIDs were unrelated to helio-geomagnetic disturbances (2008-2009 exhibited solar minimum and quiet geomagnetic conditions). The analysis of other potential sources of the observed short-period wave disturbances shows that observed TIDs do not always coincide in time with passage of local meteorological fronts through the region of subionospheric points of OS paths and are not associated with passage of solar terminator. An attempt was made to connect a number of detected TIDs with ionospheric responses to tropical cyclones (TC) which were in active phase in the north-west of the Pacific Ocean during the periods considered. A considerable

  4. Design optimization of structural parameters in double gate MOSFETs for RF applications

    International Nuclear Information System (INIS)

    Liang Jiale; Xiao Han; Huang Ru; Wang Pengfei; Wang Yangyuan

    2008-01-01

    Double gate (DG) MOSFETs have recently attracted much attention for both logic and analog/RF applications. In this paper we focus on the design consideration of DG devices for RF applications. The different influences of key structural parameters on RF characteristics are comprehensively studied and optimized, including body thickness, spacer length and source/drain raised height. The impact of the fluctuation of geometrical parameters of DG devices on RF figures-of-merit are estimated. In addition, different dominance of structural parameters for RF applications is studied in DG devices with different channel lengths. The dependence of RF performance on the gate length downscaling of DG devices is also discussed. The obtained results give the design guidelines for DG devices for RF applications

  5. Comparison of the hypothetical (57)Co brachytherapy source with the (192)Ir source.

    Science.gov (United States)

    Toossi, Mohammad Taghi Bahreyni; Ghorbani, Mahdi; Rostami, Atefeh; Khosroabadi, Mohsen; Khademi, Sara; Knaup, Courtney

    2016-01-01

    The (57)Co radioisotope has recently been proposed as a hypothetical brachytherapy source due to its high specific activity, appropriate half-life (272 days) and medium energy photons (114.17 keV on average). In this study, Task Group No. 43 dosimetric parameters were calculated and reported for a hypothetical (57)Co source. A hypothetical (57)Co source was simulated in MCNPX, consisting of an active cylinder with 3.5 mm length and 0.6 mm radius encapsulated in a stainless steel capsule. Three photon energies were utilized (136 keV [10.68%], 122 keV [85.60%], 14 keV [9.16%]) for the (57)Co source. Air kerma strength, dose rate constant, radial dose function, anisotropy function, and isodose curves for the source were calculated and compared to the corresponding data for a (192)Ir source. The results are presented as tables and figures. Air kerma strength per 1 mCi activity for the (57)Co source was 0.46 cGyh(-1) cm 2 mCi(-1). The dose rate constant for the (57)Co source was determined to be 1.215 cGyh(-1)U(-1). The radial dose function for the (57)Co source has an increasing trend due to multiple scattering of low energy photons. The anisotropy function for the (57)Co source at various distances from the source is more isotropic than the (192)Ir source. The (57)Co source has advantages over (192)Ir due to its lower energy photons, longer half-life, higher dose rate constant and more isotropic anisotropic function. However, the (192)Ir source has a higher initial air kerma strength and more uniform radial dose function. These properties make (57)Co a suitable source for use in brachytherapy applications.

  6. Sourcing of internal auditing : An empirical study

    NARCIS (Netherlands)

    Speklé, R.F.; Elten, van H.J.; Kruis, A.

    2007-01-01

    This paper studies the factors associated with organizations’ internal audit sourcing decisions, building from a previous study by Widener and Selto (henceforth W&S) [Widener, S.K., Selto, F.H., 1999. Management control systems and boundaries of the firm: why do firms outsource internal audit

  7. Bias analysis applied to Agricultural Health Study publications to estimate non-random sources of uncertainty.

    Science.gov (United States)

    Lash, Timothy L

    2007-11-26

    The associations of pesticide exposure with disease outcomes are estimated without the benefit of a randomized design. For this reason and others, these studies are susceptible to systematic errors. I analyzed studies of the associations between alachlor and glyphosate exposure and cancer incidence, both derived from the Agricultural Health Study cohort, to quantify the bias and uncertainty potentially attributable to systematic error. For each study, I identified the prominent result and important sources of systematic error that might affect it. I assigned probability distributions to the bias parameters that allow quantification of the bias, drew a value at random from each assigned distribution, and calculated the estimate of effect adjusted for the biases. By repeating the draw and adjustment process over multiple iterations, I generated a frequency distribution of adjusted results, from which I obtained a point estimate and simulation interval. These methods were applied without access to the primary record-level dataset. The conventional estimates of effect associating alachlor and glyphosate exposure with cancer incidence were likely biased away from the null and understated the uncertainty by quantifying only random error. For example, the conventional p-value for a test of trend in the alachlor study equaled 0.02, whereas fewer than 20% of the bias analysis iterations yielded a p-value of 0.02 or lower. Similarly, the conventional fully-adjusted result associating glyphosate exposure with multiple myleoma equaled 2.6 with 95% confidence interval of 0.7 to 9.4. The frequency distribution generated by the bias analysis yielded a median hazard ratio equal to 1.5 with 95% simulation interval of 0.4 to 8.9, which was 66% wider than the conventional interval. Bias analysis provides a more complete picture of true uncertainty than conventional frequentist statistical analysis accompanied by a qualitative description of study limitations. The latter approach is

  8. Bias analysis applied to Agricultural Health Study publications to estimate non-random sources of uncertainty

    Directory of Open Access Journals (Sweden)

    Lash Timothy L

    2007-11-01

    Full Text Available Abstract Background The associations of pesticide exposure with disease outcomes are estimated without the benefit of a randomized design. For this reason and others, these studies are susceptible to systematic errors. I analyzed studies of the associations between alachlor and glyphosate exposure and cancer incidence, both derived from the Agricultural Health Study cohort, to quantify the bias and uncertainty potentially attributable to systematic error. Methods For each study, I identified the prominent result and important sources of systematic error that might affect it. I assigned probability distributions to the bias parameters that allow quantification of the bias, drew a value at random from each assigned distribution, and calculated the estimate of effect adjusted for the biases. By repeating the draw and adjustment process over multiple iterations, I generated a frequency distribution of adjusted results, from which I obtained a point estimate and simulation interval. These methods were applied without access to the primary record-level dataset. Results The conventional estimates of effect associating alachlor and glyphosate exposure with cancer incidence were likely biased away from the null and understated the uncertainty by quantifying only random error. For example, the conventional p-value for a test of trend in the alachlor study equaled 0.02, whereas fewer than 20% of the bias analysis iterations yielded a p-value of 0.02 or lower. Similarly, the conventional fully-adjusted result associating glyphosate exposure with multiple myleoma equaled 2.6 with 95% confidence interval of 0.7 to 9.4. The frequency distribution generated by the bias analysis yielded a median hazard ratio equal to 1.5 with 95% simulation interval of 0.4 to 8.9, which was 66% wider than the conventional interval. Conclusion Bias analysis provides a more complete picture of true uncertainty than conventional frequentist statistical analysis accompanied by a

  9. The earthquake sequence of 21-22 February, 1983 at Ramnicu Sarat, Romania: source parameters retrieved by short period local data inversion

    International Nuclear Information System (INIS)

    Ardeleanu, L.; Radulian, M.; Sileny, J.; Panza, G. F.

    2002-01-01

    High-frequency seismograms from the Romanian telemetered local network are inverted to retrieve the seismic moment tensor of five weak earthquakes (2.9 ≤ M L ≤ 3.6) belonging to the seismic sequence of Ramnicu Sarat (Romania) of 21-22 February 1983. A grossly simplified 1-D approximation of the crust - the horizontally layered inelastic earth model - is used to construct the Green's function by modal summation. The deviation from the real velocity structure originates the error in forward modelling, which is roughly estimated from the differences in the moment tensor rate functions obtained from subsets of the complete station network. This error is transformed into estimates of confidence regions of the time function, moment tensor and its principal axes, and error bars of the scalar moment. The 1-D approximation of the crust results in a large uncertainty of the source time function, which is almost completely undetermined. The mechanism is more confident, especially the determination of the orientation of its deviatoric part. The most robust source parameter from the three investigated items is the scalar moment. (authors)

  10. Test and Control System for Chlorophyll Fluorescence Parameters Using LED as Excitation Source

    Directory of Open Access Journals (Sweden)

    Zou Qiuying

    2014-05-01

    Full Text Available A new scheme on test and control system for chlorophyll fluorescence is presented in this work, which uses light-emitting diode (LED excitation by means of measuring the fluorescence parameter fpsII. The system takes programmable power supply as LEDs illumination drive power with high sensitivity and signal-to-noise ratio. MINIPAM is used to measure fluorescence parameter fpsII and keeps communication with upper PC by serial port. The upper PC can control the power supply and process the data received from MINIPAM by software which is programmed in VB6. The results show that the system has a lot of advantages such as high accuracy and convenience. The effect of environmental factors on fluorescence parameters is analyzed comprehensively. It will be a practical measurement and control system for photosynthetic ability and have wide application foreground.

  11. Using the Talbot_Lau_interferometer_parameters Spreadsheet

    Energy Technology Data Exchange (ETDEWEB)

    Kallman, Jeffrey S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-04

    Talbot-Lau interferometers allow incoherent X-ray sources to be used for phase contrast imaging. A spreadsheet for exploring the parameter space of Talbot and Talbot-Lau interferometers has been assembled. This spreadsheet allows the user to examine the consequences of choosing phase grating pitch, source energy, and source location on the overall geometry of a Talbot or Talbot-Lau X-ray interferometer. For the X-ray energies required to penetrate scanned luggage the spacing between gratings is large enough that the mechanical tolerances for amplitude grating positioning are unlikely to be met.

  12. Influence of core model parameters on the characteristics of neutron beams of the research reactor

    Directory of Open Access Journals (Sweden)

    N. A. Khafizova

    2013-12-01

    Full Text Available IRT MEPhI reactor is equipped with a number of facilities at horizontal experimental channels (HEC. Knowing of parameters influencing spatio-angular distribution of irradiation fields is essential for each application area. The research for neutron capture therapy (NCT facility at HEC of the reactor was made. Calculation methods have been used to estimate how the reactor core parameters influence neutron beam characteristics at the HEC output. The impact of neutron source model in Monte Carlo calculations by MCNP code on the parameters of neutron and secondary photon field at the output of irradiation beam tubes of research reactor is estimated. The study shows that specifying neutron source with fission reaction rate distribution in SDEF option gives almost the same results as criticality calculation considered the most accurate. Our calculations show that changes of the core operational parameters have insignificant influence on characteristics of neutron beams at HEC output.

  13. Observational constraints on the cosmological evolution of extragalactic radio sources

    International Nuclear Information System (INIS)

    Perryman, M.A.C.

    1979-11-01

    The thesis discusses statistical studies of the remote radio sources, taking into account the various parameters for such sources, based on data from the various Cambridge Catalogues. Some of the sources have optical counterparts which yield distances from their redshifts. Combining optical and radio observations, an attempt is made to investigate whether large-scale evolution of galaxies occurs as one looks backwards in time to early epochs. Special attention is paid to ensuring that the optical identifications of the selected radio sources are sound and that the selection procedures do not distort the inferences obtained. (U.K.)

  14. Effect of organic sources of minerals on fat-corrected milk yield of dairy cows in confinement

    Directory of Open Access Journals (Sweden)

    Tiago Antonio Del Valle

    2015-03-01

    Full Text Available This study evaluated the effects of organic and inorganic sources of minerals in diets for mid-lactation dairy cows on milk yield and composition, intake and total apparent digestibility of dry matter and nutrients, blood parameters, microbial protein synthesis, and energy and protein balances. Twenty Holstein cows averaging 146.83±67.34 days in milk and weighing 625.30±80.37 kg were used. The experimental design was a crossover. Diets were composed of corn silage (50%, ground grain corn, and soybean meal, differing with regard to the sources of trace minerals, plus an organic and inorganic mix. The organic mineral source increased milk fat and fat-corrected milk yield without changing milk yield, intake, or total apparent digestibility. Blood parameters, microbial protein synthesis, and energy and protein balances were not affected by the sources of minerals. Organic sources of minerals improve milk fat yield without affecting other parameters.

  15. Review of SFR In-Vessel Radiological Source Term Studies

    International Nuclear Information System (INIS)

    Suk, Soo Dong; Lee, Yong Bum

    2008-10-01

    An effort has been made in this study to search for and review the literatures in public domain on the studies of the phenomena related to the release of radionuclides and aerosols to the reactor containment of the sodium fast reactor (SFR) plants (i.e., in-vessel source term), made in Japan and Europe including France, Germany and UK over the last few decades. Review work is focused on the experimental programs to investigate the phenomena related to determining the source terms, with a brief review on supporting analytical models and computer programs. In this report, the research programs conducted to investigate the CDA (core disruptive accident) bubble behavior in the sodium pool for determining 'primary' or 'instantaneous' source term are first introduced. The studies performed to determine 'delayed source term' are then described, including the various stages of phenomena and processes: fission product (FP) release from fuel , evaporation release from the surface of the pool, iodine mass transfer from fission gas bubble, FP deposition , and aerosol release from core-concrete interaction. The research programs to investigate the release and transport of FPs and aerosols in the reactor containment (i.e., in-containment source term) are not described in this report

  16. About the Modeling of Radio Source Time Series as Linear Splines

    Science.gov (United States)

    Karbon, Maria; Heinkelmann, Robert; Mora-Diaz, Julian; Xu, Minghui; Nilsson, Tobias; Schuh, Harald

    2016-12-01

    Many of the time series of radio sources observed in geodetic VLBI show variations, caused mainly by changes in source structure. However, until now it has been common practice to consider source positions as invariant, or to exclude known misbehaving sources from the datum conditions. This may lead to a degradation of the estimated parameters, as unmodeled apparent source position variations can propagate to the other parameters through the least squares adjustment. In this paper we will introduce an automated algorithm capable of parameterizing the radio source coordinates as linear splines.

  17. Neutronics of pulsed spallation neutron sources

    CERN Document Server

    Watanabe, N

    2003-01-01

    Various topics and issues on the neutronics of pulsed spallation neutron sources, mainly for neutron scattering experiments, are reviewed to give a wide circle of readers a better understanding of these sources in order to achieve a high neutronic performance. Starting from what neutrons are needed, what the spallation reaction is and how to produce slow-neutrons more efficiently, the outline of the target and moderator neutronics are explained. Various efforts with some new concepts or ideas have already been devoted to obtaining the highest possible slow-neutron intensity with desired pulse characteristics. This paper also reviews the recent progress of such efforts, mainly focused on moderator neutronics, since moderators are the final devices of a neutron source, which determine the source performance. Various governing parameters for neutron-pulse characteristics such as material issues, geometrical parameters (shape and dimensions), the target-moderator coupling scheme, the ortho-para-hydrogen ratio, po...

  18. Fully probabilistic seismic source inversion – Part 1: Efficient parameterisation

    Directory of Open Access Journals (Sweden)

    S. C. Stähler

    2014-11-01

    Full Text Available Seismic source inversion is a non-linear problem in seismology where not just the earthquake parameters themselves but also estimates of their uncertainties are of great practical importance. Probabilistic source inversion (Bayesian inference is very adapted to this challenge, provided that the parameter space can be chosen small enough to make Bayesian sampling computationally feasible. We propose a framework for PRobabilistic Inference of Seismic source Mechanisms (PRISM that parameterises and samples earthquake depth, moment tensor, and source time function efficiently by using information from previous non-Bayesian inversions. The source time function is expressed as a weighted sum of a small number of empirical orthogonal functions, which were derived from a catalogue of >1000 source time functions (STFs by a principal component analysis. We use a likelihood model based on the cross-correlation misfit between observed and predicted waveforms. The resulting ensemble of solutions provides full uncertainty and covariance information for the source parameters, and permits propagating these source uncertainties into travel time estimates used for seismic tomography. The computational effort is such that routine, global estimation of earthquake mechanisms and source time functions from teleseismic broadband waveforms is feasible.

  19. Development of fault parameters for use in risk assessment modeling in the Pasco Basin, Columbia Plateau, South Central Washington: a preliminary study

    International Nuclear Information System (INIS)

    Caggiano, J.A.

    1982-03-01

    Preliminary data on strain rate, seismicity, and estimated earthquake source parameters suggest limitations on the extent of postulated faulting and its impact on a nuclear waste repository in Columbia River basalt. Structural relief of dated basalt flows, attitude of Pliocene sediments, geodetic surveys, size and distribution of earthquakes, and focal mechanism solutions indicate that deformation of basalt under north-south compression was under way in the Miocene and has continued on existing structures at an average rate of much less than 1 mm/yr in the Pasco Basin. Lengths and displacements of mapped faults suggest limits on the postulated fault that could intersect a repository and produce an earthquake of about magnitude 6.5. Using a credible earthquake permits calculation of preliminary source parameters for risk assessment modeling during a single episode of slip on the postulated new fault and indicates displacement of less than or equal to 1, m on a steeply dipping fault of less than or equal to 50 km length could occur. Preliminary source parameter calculations suggest that displacements of less than or equal to 2 cm may occur during microearthquakes in swarms. The area of fault rupture may be tens of square meters up to a few square kilometers, suggesting slip on joints. Seismic moments for postulated earthquakes in the interconnecting fault and microearthquake scenarios compare favorably with reported values for similar-sized earthquakes in different media and suggest that the estimated fault parameters are reasonable until an adequate tectonic model has been developed

  20. Effect of Different Solar Radiation Data Sources on the Variation of Techno-Economic Feasibility of PV Power System

    Science.gov (United States)

    Alghoul, M. A.; Ali, Amer; Kannanaikal, F. V.; Amin, N.; Aljaafar, A. A.; Kadhim, Mohammed; Sopian, K.

    2017-11-01

    The aim of this study is to evaluate the variation in techno-economic feasibility of PV power system under different data sources of solar radiation. HOMER simulation tool is used to predict the techno-economic feasibility parameters of PV power system in Baghdad city, Iraq located at (33.3128° N, 44.3615° E) as a case study. Four data sources of solar radiation, different annual capacity shortages percentage (0, 2.5, 5, and 7.5), and wide range of daily load profile (10-100 kWh/day) are implemented. The analyzed parameters of the techno-economic feasibility are COE (/kWh), PV array power capacity (kW), PV electrical production (kWh/year), No. of batteries and battery lifetime (year). The main results of the study revealed the followings: (1) solar radiation from different data sources caused observed to significant variation in the values of the techno-economic feasibility parameters; therefore, careful attention must be paid to ensure the use of an accurate solar input data; (2) Average solar radiation from different data sources can be recommended as a reasonable input data; (3) it is observed that as the size and of PV power system increases, the effect of different data sources of solar radiation increases and causes significant variation in the values of the techno-economic feasibility parameters.

  1. National synchrotron light source basic design and project status

    International Nuclear Information System (INIS)

    van Steenbergen, A.

    1981-01-01

    A summary description and the basic design parameters of the National Synchrotron Light Source, a facility for the generation of intense synchrotron radiation in the vuv and x-ray range is presented, the parameters of the sources are given, the presently planned facility beam lines are tabulated and the status of the project is indicated

  2. Study on the Energetic Parameters in a Photothermic Sensor with ...

    African Journals Online (AJOL)

    Study on the Energetic Parameters in a Photothermic Sensor with Black Polymeric Film. ... The evolution of incidental solar illumination on the horizontal plan of sensor and the temperature distribution are studied. Results showed that the ... Keywords: film, solar energy, greenhouse effect, design, radiation, illumination.

  3. Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2015-07-01

    Full Text Available Introduction Based on Task Group No. 43 (TG-43U1 recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods TG-43 parameters of low- and high-energy brachytherapy sources (i.e., Pd-103, I-125 and Cs-137 were obtained in different phantoms, using Monte Carlo simulations. The brachytherapy sources were simulated at the center of different phantoms including water, solid water, poly(methyl methacrylate, polystyrene and polyethylene. Dosimetric parameters such as dose rate constant, radial dose function and anisotropy function of each source were compared in different phantoms. Then, conversion factors were obtained to make phantom parameters equivalent to those of water. Results Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water. Conclusion Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water.

  4. Composition, nutritional aspects and effect on serum parameters of marine algae Ulva rigida.

    Science.gov (United States)

    Taboada, Cristina; Millán, Rosendo; Míguez, Isabel

    2010-02-01

    Algae are commonly consumed in Asia and have also gained popularity in Europe. However, data on the bioavailability of their components are limited. The present study was designed to determine the composition of Ulva rigida and the effects of inclusion of 10% of the algae in a standard diet for 4 weeks on nutritive value and serum parameters in order to consider the usefulness of Ulva as a dietary supplement. Ulva rigida is rich in protein, carbohydrates, fibre, vitamins and minerals and has a low lipid content. Analysis of the amino acid composition revealed good-quality protein. The algae were well accepted by experimental animals and did not significantly change nutritional parameters but reduced LDL cholesterol. Ulva rigida is an excellent source of nutrients and could improve a balanced diet. Further studies are required to research the potential of the seaweed as a natural source of bioactive compounds.

  5. Combining historical eyewitness accounts on tsunami-induced waves and numerical simulations for getting insights in uncertainty of source parameters

    Science.gov (United States)

    Rohmer, Jeremy; Rousseau, Marie; Lemoine, Anne; Pedreros, Rodrigo; Lambert, Jerome; benki, Aalae

    2017-04-01

    and numerical simulations. In order to learn the uncertainty information on source parameters, we treat the problem within the Bayesian setting, which enables to incorporate in a flexible manner the different uncertainty sources. We propose to rely on an emerging technique called Approximate Bayesian Computation ABC, which has been developed to estimate the posterior distribution in modelling scenarios where the likelihood function is either unknown or cannot be explicitly defined. To overcome the computational issue, we combine ABC with statistical emulators (aka meta-model). We apply the proposed approach on the case study of Ligurian (North West of Italy) tsunami (1887) and discuss the results with a special attention paid to the impact of the observational error.

  6. Estimation of Genetic Parameters for Fat Deposition and Carcass Traits in Broilers

    NARCIS (Netherlands)

    Zerehdaran, S.; Vereijken, A.L.J.; Arendonk, van J.A.M.; Waaij, van der E.H.

    2004-01-01

    Abdominal and subcutaneous fat are regarded as the main sources of waste in the slaughterhouse. Fat stored intramuscularly is regarded a favorite trait related to meat quality. The objective of current study was to estimate genetic parameters for fat deposition in the 3 different parts of body and

  7. The normative study of acoustic parameters in normal Egyptian ...

    African Journals Online (AJOL)

    Yehia A. Abo-Ras

    2013-03-21

    Mar 21, 2013 ... all children were subjected to computerized acoustic analysis using Multidimensional voice program ... cal quality is important for social relations to happen effectively. ... lish comparative parameters with the normal values of the acoustic ... from lower age ranges in the normative studies since the child's.

  8. Identification of Important Parameter from Leachate Solid Waste Landfill on Water Quality, Case Study of Pesanggrahan River

    Science.gov (United States)

    Yanidar, R.; Hartono, D. M.; Moersidik, S. S.

    2018-03-01

    Cipayung Landfill takes waste generation from Depok City approximately ± 750 tons/day of solid waste. The south and west boundaries of the landfill is Pesanggarahan River which 200m faraway. The objectives of this study are to indicate an important parameter which greatly affects the water quality of Pesanggrahan River and purpose the dynamic model for improving our understanding of the dynamic behavior that captures the interactions and feedbacks important parameter in river in order to identify and assess the effects of the treated leachate from final solid waste disposal activity as it responds to changes over time in the river. The high concentrations of BOD and COD are not the only cause significantly affect the quality of the pesanggrahan water, it also because the river has been contaminated in the upstream area. It need the water quality model to support the effectiveness calculation of activities for preventing a selected the pollutant sources the model should be developed for simulating and predicting the trend of water quality performance in Pesanggrahan River which can potentially be used by policy makers in strategic management to sustain river water quality as raw drinking water.

  9. Study on possibility of development of a laser multicharged ion source for a heavy ion fusion driver

    International Nuclear Information System (INIS)

    Barabash, L.Z.; Krechet, K.I.; Lapitskij, Yu.Ya.; Latyshev, S.V.; Shumshurov, A.V.

    1983-01-01

    The results of studying laser produced plasma ion sources for a heavy ion accelerating-storage complex used as a heavy ion fusion driver are presented. The following parameters were measured on an installation aimed for studying physical characteristics of heavy ion laser plasma for a lead target at laser radiation flux density of approximately 3x10 10 W/cm 2 : scattered ion charge composition, energy spectra and scattering angle distributions, ion currents, absolute number of ions in every charge state, plasma electron temperature. The ion current pulse duration varied from 3x10 -4 s at Z +1 to 2x10 -5 s at Z +10 . The maximum current amplitude of 2 mA corresponded to Z +7 charge. The scattering velocity increased with charge. The total number of ions that could be used for acceleration was approximately 5x10 13 for Z +2 and 5x10 12 for Z +6 per pulse. The ion laser source brightness was 2x10 11 A/cm 2 , the particle phase density was 10 18 (cmxrad) -1

  10. On The Computation Of The Best-fit Okada-type Tsunami Source

    Science.gov (United States)

    Miranda, J. M. A.; Luis, J. M. F.; Baptista, M. A.

    2017-12-01

    The forward simulation of earthquake-induced tsunamis usually assumes that the initial sea surface elevation mimics the co-seismic deformation of the ocean bottom described by a simple "Okada-type" source (rectangular fault with constant slip in a homogeneous elastic half space). This approach is highly effective, in particular in far-field conditions. With this assumption, and a given set of tsunami waveforms recorded by deep sea pressure sensors and (or) coastal tide stations it is possible to deduce the set of parameters of the Okada-type solution that best fits a set of sea level observations. To do this, we build a "space of possible tsunami sources-solution space". Each solution consists of a combination of parameters: earthquake magnitude, length, width, slip, depth and angles - strike, rake, and dip. To constrain the number of possible solutions we use the earthquake parameters defined by seismology and establish a range of possible values for each parameter. We select the "best Okada source" by comparison of the results of direct tsunami modeling using the solution space of tsunami sources. However, direct tsunami modeling is a time-consuming process for the whole solution space. To overcome this problem, we use a precomputed database of Empirical Green Functions to compute the tsunami waveforms resulting from unit water sources and search which one best matches the observations. In this study, we use as a test case the Solomon Islands tsunami of 6 February 2013 caused by a magnitude 8.0 earthquake. The "best Okada" source is the solution that best matches the tsunami recorded at six DART stations in the area. We discuss the differences between the initial seismic solution and the final one obtained from tsunami data This publication received funding of FCT-project UID/GEO/50019/2013-Instituto Dom Luiz.

  11. 4th generation light source instrumentation

    International Nuclear Information System (INIS)

    Lumpkin, A.

    1998-01-01

    This working group on 4th Generation Light Source (4GLS) Instrumentation was a follow-up to the opening-discussion on Challenges in Beam Profiling. It was in parallel with the Feedback Systems session. We filled the SSRL Conference Room with about 25 participants. The session opened with an introduction by Lumpkin. The target beam parameter values for a few-angstrom, self-amplified spontaneous emissions (SASE) experiment and for a diffraction-limited soft x-ray storage ring source were addressed. Instrument resolution would of course need to be 2-3 times better than the value measured, if possible. The nominal targeted performance parameters are emittance (1-2π mm mrad), bunch length (100 fs), peak-current (l-5 kA), beam size (10 microm), beam divergence (1 microrad), energy spread (2 x 10 -4 ), and beam energy (10's of GeV). These are mostly the SASE values, and the possible parameters for a diffraction-limited soft x-ray source would be relaxed somewhat. Beam stability and alignment specifications in the sub-micron domain for either device are anticipated

  12. Source position error influence on industry CT image quality

    International Nuclear Information System (INIS)

    Cong Peng; Li Zhipeng; Wu Haifeng

    2004-01-01

    Based on the emulational exercise, the influence of source position error on industry CT (ICT) image quality was studied and the valuable parameters were obtained for the design of ICT. The vivid container CT image was also acquired from the CT testing system. (authors)

  13. Earthquake Source Spectral Study beyond the Omega-Square Model

    Science.gov (United States)

    Uchide, T.; Imanishi, K.

    2017-12-01

    Earthquake source spectra have been used for characterizing earthquake source processes quantitatively and, at the same time, simply, so that we can analyze the source spectra for many earthquakes, especially for small earthquakes, at once and compare them each other. A standard model for the source spectra is the omega-square model, which has the flat spectrum and the falloff inversely proportional to the square of frequencies at low and high frequencies, respectively, which are bordered by a corner frequency. The corner frequency has often been converted to the stress drop under the assumption of circular crack models. However, recent studies claimed the existence of another corner frequency [Denolle and Shearer, 2016; Uchide and Imanishi, 2016] thanks to the recent development of seismic networks. We have found that many earthquakes in areas other than the area studied by Uchide and Imanishi [2016] also have source spectra deviating from the omega-square model. Another part of the earthquake spectra we now focus on is the falloff rate at high frequencies, which will affect the seismic energy estimation [e.g., Hirano and Yagi, 2017]. In June, 2016, we deployed seven velocity seismometers in the northern Ibaraki prefecture, where the shallow crustal seismicity mainly with normal-faulting events was activated by the 2011 Tohoku-oki earthquake. We have recorded seismograms at 1000 samples per second and at a short distance from the source, so that we can investigate the high-frequency components of the earthquake source spectra. Although we are still in the stage of discovery and confirmation of the deviation from the standard omega-square model, the update of the earthquake source spectrum model will help us systematically extract more information on the earthquake source process.

  14. The peak efficiency calibration of volume source using 152Eu point source in computer

    International Nuclear Information System (INIS)

    Shen Tingyun; Qian Jianfu; Nan Qinliang; Zhou Yanguo

    1997-01-01

    The author describes the method of the peak efficiency calibration of volume source by means of 152 Eu point source for HPGe γ spectrometer. The peak efficiency can be computed by Monte Carlo simulation, after inputting parameter of detector. The computation results are in agreement with the experimental results with an error of +-3.8%, with an exception one is about +-7.4%

  15. Laser-induced extreme UV radiation sources for manufacturing next-generation integrated circuits

    International Nuclear Information System (INIS)

    Borisov, V M; Vinokhodov, A Yu; Ivanov, A S; Kiryukhin, Yu B; Mishchenko, V A; Prokof'ev, A V; Khristoforov, O B

    2009-01-01

    The development of high-power discharge sources emitting in the 13.5±0.135-nm spectral band is of current interest because they are promising for applications in industrial EUV (extreme ultraviolet) lithography for manufacturing integrated circuits according to technological precision standards of 22 nm and smaller. The parameters of EUV sources based on a laser-induced discharge in tin vapours between rotating disc electrodes are investigated. The properties of the discharge initiation by laser radiation at different wavelengths are established and the laser pulse parameters providing the maximum energy characteristics of the EUV source are determined. The EUV source developed in the study emits an average power of 276 W in the 13.5±0.135-nm spectral band on conversion to the solid angle 2π sr in the stationary regime at a pulse repetition rate of 3000 Hz. (laser applications and other topics in quantum electronics)

  16. Water quality assessment and apportionment of pollution sources of Gomti river (India) using multivariate statistical techniques--a case study

    International Nuclear Information System (INIS)

    Singh, Kunwar P.; Malik, Amrita; Sinha, Sarita

    2005-01-01

    Multivariate statistical techniques, such as cluster analysis (CA), factor analysis (FA), principal component analysis (PCA) and discriminant analysis (DA) were applied to the data set on water quality of the Gomti river (India), generated during three years (1999-2001) monitoring at eight different sites for 34 parameters (9792 observations). This study presents usefulness of multivariate statistical techniques for evaluation and interpretation of large complex water quality data sets and apportionment of pollution sources/factors with a view to get better information about the water quality and design of monitoring network for effective management of water resources. Three significant groups, upper catchments (UC), middle catchments (MC) and lower catchments (LC) of sampling sites were obtained through CA on the basis of similarity between them. FA/PCA applied to the data sets pertaining to three catchments regions of the river resulted in seven, seven and six latent factors, respectively responsible for the data structure, explaining 74.3, 73.6 and 81.4% of the total variance of the respective data sets. These included the trace metals group (leaching from soil and industrial waste disposal sites), organic pollution group (municipal and industrial effluents), nutrients group (agricultural runoff), alkalinity, hardness, EC and solids (soil leaching and runoff process). DA showed the best results for data reduction and pattern recognition during both temporal and spatial analysis. It rendered five parameters (temperature, total alkalinity, Cl, Na and K) affording more than 94% right assignations in temporal analysis, while 10 parameters (river discharge, pH, BOD, Cl, F, PO 4 , NH 4 -N, NO 3 -N, TKN and Zn) to afford 97% right assignations in spatial analysis of three different regions in the basin. Thus, DA allowed reduction in dimensionality of the large data set, delineating a few indicator parameters responsible for large variations in water quality. Further

  17. Developing the Parameters of Scholarship in Postgraduate Coursework Studies

    Science.gov (United States)

    McLay, Allan F.

    2013-01-01

    Scholarship parameters, in relation to postgraduate coursework studies, are developed against the expectations of the Boyer classifications of scholarship (Boyer, 1990) with particular emphasis on the role of minor thesis development. An example is presented in which postgraduate coursework students are required to undertake a three semester minor…

  18. The Competition Between a Localised and Distributed Source of Buoyancy

    Science.gov (United States)

    Partridge, Jamie; Linden, Paul

    2012-11-01

    We propose a new mathematical model to study the competition between localised and distributed sources of buoyancy within a naturally ventilated filling box. The main controlling parameters in this configuration are the buoyancy fluxes of the distributed and local source, specifically their ratio Ψ. The steady state dynamics of the flow are heavily dependent on this parameter. For large Ψ, where the distributed source dominates, we find the space becomes well mixed as expected if driven by an distributed source alone. Conversely, for small Ψ we find the space reaches a stable two layer stratification. This is analogous to the classical case of a purely local source but here the lower layer is buoyant compared to the ambient, due to the constant flux of buoyancy emanating from the distributed source. The ventilation flow rate, buoyancy of the layers and also the location of the interface height, which separates the two layer stratification, are obtainable from the model. To validate the theoretical model, small scale laboratory experiments were carried out. Water was used as the working medium with buoyancy being driven directly by temperature differences. Theoretical results were compared with experimental data and overall good agreement was found. A CASE award project with Arup.

  19. Normal Values for Heart Electrophysiology Parameters of Healthy Swine Determined on Electrophysiology Study.

    Science.gov (United States)

    Noszczyk-Nowak, Agnieszka; Cepiel, Alicja; Janiszewski, Adrian; Pasławski, Robert; Gajek, Jacek; Pasławska, Urszula; Nicpoń, Józef

    2016-01-01

    Swine are a well-recognized animal model for human cardiovascular diseases. Despite the widespread use of porcine model in experimental electrophysiology, still no reference values for intracardiac electrical activity and conduction parameters determined during an invasive electrophysiology study (EPS) have been developed in this species thus far. The aim of the study was to develop a set of normal values for intracardiac electrical activity and conduction parameters determined during an invasive EPS of swine. The study included 36 healthy domestic swine (24-40 kg body weight). EPS was performed under a general anesthesia with midazolam, propofol and isoflurane. The reference values for intracardiac electrical activity and conduction parameters were calculated as arithmetic means ± 2 standard deviations. The reference values were determined for AH, HV and PA intervals, interatrial conduction time at its own and imposed rhythm, sinus node recovery time (SNRT), corrected sinus node recovery time (CSNRT), anterograde and retrograde Wenckebach points, atrial, atrioventricular node and ventricular refractory periods. No significant correlations were found between body weight and heart rate of the examined pigs and their electrophysiological parameters. The hereby presented reference values can be helpful in comparing the results of various studies, as well as in more accurately estimating the values of electrophysiological parameters that can be expected in a given experiment.

  20. Seasonal abundance of epipelic algae and sediment parameters of ...

    African Journals Online (AJOL)

    Amadi-Ama creek is located close to sources of wastes which are introduced into the creek thus altering the physico-chemical parameters and the aquatic biota of the creek due to variation in nutrient load of the water. The seasonal abundance of epipelic algae and sediment parameters of Amadi-Ama Creek were ...

  1. Strategies for source space limitation in tomographic inverse procedures

    International Nuclear Information System (INIS)

    George, J.S.; Lewis, P.S.; Schlitt, H.A.; Kaplan, L.; Gorodnitsky, I.; Wood, C.C.

    1994-01-01

    The use of magnetic recordings for localization of neural activity requires the solution of an ill-posed inverse problem: i.e. the determination of the spatial configuration, orientation, and timecourse of the currents that give rise to a particular observed field distribution. In its general form, this inverse problem has no unique solution; due to superposition and the existence of silent source configurations, a particular magnetic field distribution at the head surface could be produced by any number of possible source configurations. However, by making assumptions concerning the number and properties of neural sources, it is possible to use numerical minimization techniques to determine the source model parameters that best account for the experimental observations while satisfying numerical or physical criteria. In this paper the authors describe progress on the development and validation of inverse procedures that produce distributed estimates of neuronal currents. The goal is to produce a temporal sequence of 3-D tomographic reconstructions of the spatial patterns of neural activation. Such approaches have a number of advantages, in principle. Because they do not require estimates of model order and parameter values (beyond specification of the source space), they minimize the influence of investigator decisions and are suitable for automated analyses. These techniques also allow localization of sources that are not point-like; experimental studies of cognitive processes and of spontaneous brain activity are likely to require distributed source models

  2. Simulation study on ion extraction from ECR ion sources

    International Nuclear Information System (INIS)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author)

  3. Simulation study on ion extraction from ECR ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Fu, S.; Kitagawa, A.; Yamada, S.

    1993-07-01

    In order to study beam optics of NIRS-ECR ion source used in HIMAC, EGUN code has been modified to make it capable of modeling ion extraction from a plasma. Two versions of the modified code are worked out with two different methods in which 1-D and 2-D sheath theories are used respectively. Convergence problem of the strong nonlinear self-consistent equations is investigated. Simulations on NIRS-ECR ion source and HYPER-ECR ion source (in INS, Univ. of Tokyo) are presented in this paper, exhibiting an agreement with the experimental results. Some preliminary suggestions on the upgrading the extraction systems of these sources are also proposed. (author).

  4. Does recruitment source moderate treatment effectiveness? A subgroup analysis from the EVIDENT study, a randomised controlled trial of an internet intervention for depressive symptoms.

    Science.gov (United States)

    Klein, Jan Philipp; Gamon, Carla; Späth, Christina; Berger, Thomas; Meyer, Björn; Hohagen, Fritz; Hautzinger, Martin; Lutz, Wolfgang; Vettorazzi, Eik; Moritz, Steffen; Schröder, Johanna

    2017-07-13

    This study aims to examine whether the effects of internet interventions for depression generalise to participants recruited in clinical settings. This study uses subgroup analysis of the results of a randomised, controlled, single-blind trial. The study takes place in five diagnostic centres in Germany. A total of 1013 people with mild to moderate depressive symptoms were recruited from clinical sources as well as internet forums, statutory insurance companies and other sources. This study uses either care-as-usual alone (control) or a 12-week internet intervention (Deprexis) plus usual care (intervention). The primary outcome measure was self-rated depression severity (Patient Health Questionnaire-9) at 3 months and 6 months. Further measures ranged from demographic and clinical parameters to a measure of attitudes towards internet interventions (Attitudes towards Psychological Online Interventions Questionnaire). The recruitment source was only associated with very few of the examined demographic and clinical characteristics. Compared with participants recruited from clinical sources, participants recruited through insurance companies were more likely to be employed. Clinically recruited participants were as severely affected as those from other recruitment sources but more sceptical of internet interventions. The effectiveness of the intervention was not differentially associated with recruitment source (treatment by recruitment source interaction=0.28, p=0.84). Our results support the hypothesis that the intervention we studied is effective across different recruitment sources including clinical settings. ClinicalTrials.gov NCT01636752. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Optical and spectroscopic studies on tannery wastes as a possible source of organic semiconductors.

    Science.gov (United States)

    Nashy, El-Shahat H A; Al-Ashkar, Emad; Moez, A Abdel

    2012-02-01

    Tanning industry produces a large quantity of solid wastes which contain hide proteins in the form of protein shavings containing chromium salts. The chromium wastes are the main concern from an environmental stand point of view, because chrome wastes posses a significant disposal problem. The present work is devoted to investigate the possibility of utilizing these wastes as a source of organic semi-conductors as an alternative method instead of the conventional ones. The chemical characterization of these wastes was determined. In addition, the Horizontal Attenuated Total Reflection (HATR) FT-IR spectroscopic analysis and optical parameters were also carried out for chromated samples. The study showed that the chromated samples had suitable absorbance and transmittance in the wavelength range (500-850 nm). Presence of chromium salt in the collagen samples increases the absorbance which improves the optical properties of the studied samples and leads to decrease the optical energy gap. The obtained optical energy gap gives an impression that the environmentally hazardous chrome shavings wastes can be utilized as a possible source of natural organic semiconductors with direct and indirect energy gap. This work opens the door to use some hazardous wastes in the manufacture of electronic devices such as IR-detectors, solar cells and also as solar cell windows. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Overview of receptor-based source apportionment studies for speciated atmospheric mercury

    OpenAIRE

    Cheng, I.; Xu, X.; Zhang, L.

    2015-01-01

    Receptor-based source apportionment studies of speciated atmospheric mercury are not only concerned with source contributions but also with the influence of transport, transformation, and deposition processes on speciated atmospheric mercury concentrations at receptor locations. Previous studies applied multivariate receptor models including principal components analysis and positive matrix factorization, and back trajectory receptor models including potential source contri...

  7. Beam-based model of broad-band impedance of the Diamond Light Source

    Science.gov (United States)

    Smaluk, Victor; Martin, Ian; Fielder, Richard; Bartolini, Riccardo

    2015-06-01

    In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS) to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  8. Beam-based model of broad-band impedance of the Diamond Light Source

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2015-06-01

    Full Text Available In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  9. The calculation and experiment verification of geometry factors of disk sources and detectors

    International Nuclear Information System (INIS)

    Shi Zhixia; Minowa, Y.

    1993-01-01

    In alpha counting the efficiency of counting system is most frequently determined from the counter response to a calibrated source. Whenever this procedure is used, however, question invariably arise as to the integrity of the standard source, or indeed the validity of the primary calibration. As a check, therefore, it is often helped to be able to calculate the disintegration rate from counting rate data. The conclusion are: 1. If the source is thin enough the error E is generally less than 5%. It is acceptable in routine measurement. When the standard source lacks for experiment we can use the geometry factor calculated instead of measured efficiency. 2. The geometry factor calculated can be used to correct the counter system, study the effect of each parameters and identify those parameters needing careful control. 3. The method of overlapping area of the source and the projection of the detector is very believable, simple and convenient for calculating geometry. (5 tabs.)

  10. Evaluation of hypothetical (153)Gd source for use in brachytherapy.

    Science.gov (United States)

    Ghorbani, Mahdi; Behmadi, Marziyeh

    2016-01-01

    The purpose of this work is to evaluate the dosimetric parameters of a hypothetical (153)Gd source for use in brachytherapy and comparison of the dosimetric parameters with those of (192)Ir and (125)I sources. Dose rate constant, the radial dose function and the two dimensional (2D) anisotropy function data for the hypothetical (153)Gd source were obtained by simulation of the source using MCNPX code and then were compared with the corresponding data reported by Enger et al. A comprehensive comparison between this hypothetical source and a (192)Ir source with similar geometry and a (125)I source was performed as well. Excellent agreement was shown between the results of the two studies. Dose rate constant values for the hypothetical (153)Gd, (192)Ir, (125)I sources are 1.173 cGyh(-1) U(-1), 1.044 cGyh(-1) U(-1), 0.925 cGyh(-1) U(-1), respectively. Radial dose function for the hypothetical (153)Gd source has an increasing trend, while (192)Ir has more uniform and (125)I has more rapidly falling off radial dose functions. 2D anisotropy functions for these three sources indicate that, except at 0.5 cm distance, (192)Ir and (125)I have more isotropic trends as compared to the (153)Gd source. A more uniform radial dose function, and 2D anisotropy functions with more isotropy, a much higher specific activity are advantages of (192)Ir source over (153)Gd. However, a longer half-life of (153)Gd source compared to the other two sources, and lower energy of the source with respect to (192)Ir are advantages of using (153)Gd in brachytherapy versus (192)Ir source.

  11. Langmuir probe study of a magnetically enhanced RF plasma source at pressures below 0.1 Pa

    Science.gov (United States)

    Kousal, Jaroslav; Tichý, Milan; Šebek, Ondřej; Čechvala, Juraj; Biederman, Hynek

    2011-08-01

    The majority of plasma polymerization sources operate at pressures higher than 1 Pa. At these pressures most common deposition methods do not show significant directionality. One way of enhancing the directional effects is to decrease the working pressure to increase the mean free path of the reactive molecules. The plasma source used in this work was designed to study the plasma polymerization process at pressures below 0.1 Pa. The source consists of the classical radio frequency (RF) (13.56 MHz, capacitive coupled) tubular reactor enhanced by an external magnetic circuit. The working gas is introduced into the discharge by a capillary. This forms a relatively localized zone of higher pressure where the monomer is activated. Due to the magnetic field, the plasma is constricted near the axis of the reactor with nearly collisionless gas flow. The plasma parameters were obtained using a double Langmuir probe. Plasma density in the range ni = 1013-1016 m-3 was obtained in various parts of the discharge under typical conditions. The presence of the magnetic field led to the presence of relatively strong electric fields (103 V m-1) and relatively high electron energies up to several tens of eV in the plasma.

  12. Langmuir probe study of a magnetically enhanced RF plasma source at pressures below 0.1 Pa

    Energy Technology Data Exchange (ETDEWEB)

    Kousal, Jaroslav; Tichy, Milan; Sebek, Ondrej; Cechvala, Juraj; Biederman, Hynek, E-mail: jaroslav.kousal@mff.cuni.cz [Charles University in Prague, Faculty of Mathematics and Physics, V Holesovickach 2, 180 00, Prague 8 (Czech Republic)

    2011-08-15

    The majority of plasma polymerization sources operate at pressures higher than 1 Pa. At these pressures most common deposition methods do not show significant directionality. One way of enhancing the directional effects is to decrease the working pressure to increase the mean free path of the reactive molecules. The plasma source used in this work was designed to study the plasma polymerization process at pressures below 0.1 Pa. The source consists of the classical radio frequency (RF) (13.56 MHz, capacitive coupled) tubular reactor enhanced by an external magnetic circuit. The working gas is introduced into the discharge by a capillary. This forms a relatively localized zone of higher pressure where the monomer is activated. Due to the magnetic field, the plasma is constricted near the axis of the reactor with nearly collisionless gas flow. The plasma parameters were obtained using a double Langmuir probe. Plasma density in the range n{sub i} = 10{sup 13}-10{sup 16} m{sup -3} was obtained in various parts of the discharge under typical conditions. The presence of the magnetic field led to the presence of relatively strong electric fields (10{sup 3} V m{sup -1}) and relatively high electron energies up to several tens of eV in the plasma.

  13. Estimating Convection Parameters in the GFDL CM2.1 Model Using Ensemble Data Assimilation

    Science.gov (United States)

    Li, Shan; Zhang, Shaoqing; Liu, Zhengyu; Lu, Lv; Zhu, Jiang; Zhang, Xuefeng; Wu, Xinrong; Zhao, Ming; Vecchi, Gabriel A.; Zhang, Rong-Hua; Lin, Xiaopei

    2018-04-01

    Parametric uncertainty in convection parameterization is one major source of model errors that cause model climate drift. Convection parameter tuning has been widely studied in atmospheric models to help mitigate the problem. However, in a fully coupled general circulation model (CGCM), convection parameters which impact the ocean as well as the climate simulation may have different optimal values. This study explores the possibility of estimating convection parameters with an ensemble coupled data assimilation method in a CGCM. Impacts of the convection parameter estimation on climate analysis and forecast are analyzed. In a twin experiment framework, five convection parameters in the GFDL coupled model CM2.1 are estimated individually and simultaneously under both perfect and imperfect model regimes. Results show that the ensemble data assimilation method can help reduce the bias in convection parameters. With estimated convection parameters, the analyses and forecasts for both the atmosphere and the ocean are generally improved. It is also found that information in low latitudes is relatively more important for estimating convection parameters. This study further suggests that when important parameters in appropriate physical parameterizations are identified, incorporating their estimation into traditional ensemble data assimilation procedure could improve the final analysis and climate prediction.

  14. Belgrade waterworks groundwater source

    International Nuclear Information System (INIS)

    Sotic, A.; Dasic, M.; Vukcevic, G.; Vasiljevic, Lj.; Nikolic, S.

    2002-01-01

    Paper deals with Belgrade Waterworks groundwater source, its characteristics, conception of protection programme, contaminations on source and with parameters of groundwater quality degradation. Groundwaters present natural heritage with their strategic and slow renewable natural resources attributes, and as such they require priority in protection. It is of greatest need that existing source is to be protected and used optimally for producing quality drinkable water. The concept of source protection programme should be based on regular water quality monitoring, identification of contaminators, defining areas of their influences on the source and their permanent control. However, in the last 10 years, but drastically in the last 3, because of the overall situation in the country, it is very characteristic downfall in volume of business, organisation and the level of supply of the technical equipment

  15. Probing jets from young embedded sources

    Science.gov (United States)

    Nisini, Brunella

    2017-08-01

    Jets are intimately related to the process of star formation and disc accretion. Our present knowledge of this key ingredient in protostars mostly relies on observations of optical jets from T Tauri stars, where the original circumstellar envelope has been already cleared out. However, to understand how jets are originally formed and how their properties evolve with time, detailed observations of young accreting protostars, i.e. the class 0/I sources, are mandatory. The study of class0/I jets will be revolutionised by JWST, able to penetrate protostars dusty envelopes with unprecedented sensitivity and resolution. However, complementary information on parameters inferred from lines in different excitation regimes, for at least a representative sample of a few bright sources, is essential for a correct interpretation of the JWST results. Here we propose to observe four prototype bright jets from class0/I sources with the WFC3 in narrow band filters in order to acquire high angular resolution images in the [OI]6300A, [FeII]1.25 and [FeII]1.64um lines. These images will be used to: 1) provide accurate extinction maps of the jets that will be an important archival reference for any future observation on these jets. 2) measure key parameters as the mass flux, the iron abundance and the jet collimation on the hot gas component of the jets. These information will provide an invaluable reference frame for a comparison with similar parameters measured by JWST in a different gas regime. In addition, these observations will allow us to confront the properties of class 0/I jets with those of the more evolved T Tauri stars.

  16. Source apportionment studies on particulate matter in Beijing/China

    Science.gov (United States)

    Suppan, P.; Shen, R.; Shao, L.; Schrader, S.; Schäfer, K.; Norra, S.; Vogel, B.; Cen, K.; Wang, Y.

    2013-05-01

    More than 15 million people in the greater area of Beijing are still suffering from severe air pollution levels caused by sources within the city itself but also from external impacts like severe dust storms and long range advection from the southern and central part of China. Within this context particulate matter (PM) is the major air pollutant in the greater area of Beijing (Garland et al., 2009). PM did not serve only as lead substance for air quality levels and therefore for adverse health impact effects but also for a strong influence on the climate system by changing e.g. the radiative balance. Investigations on emission reductions during the Olympic Summer Games in 2008 have caused a strong reduction on coarser particles (PM10) but not on smaller particles (PM2.5). In order to discriminate the composition of the particulate matter levels, the different behavior of coarser and smaller particles investigations on source attribution, particle characteristics and external impacts on the PM levels of the city of Beijing by measurements and modeling are performed: a) Examples of long term measurements of PM2.5 filter sampling in 2010/2011 with the objectives of detailed chemical (source attribution, carbon fraction, organic speciation and inorganic composition) and isotopic analyses as well as toxicological assessment in cooperation with several institutions (Karlsruhe Institute of Technology (IfGG/IMG), Helmholtz Zentrum München (HMGU), University Rostock (UR), Chinese University of Mining and Technology Beijing, CUMTB) will be discussed. b) The impact of dust storm events on the overall pollution level of particulate matter in the greater area of Beijing is being assessed by the online coupled comprehensive model system COSMO-ART. First results of the dust storm modeling in northern China (2011, April 30th) demonstrates very well the general behavior of the meteorological parameters temperature and humidity as well as a good agreement between modeled and

  17. Evaluation of Reliability Parameters in Micro-grid

    Directory of Open Access Journals (Sweden)

    H. Hasanzadeh Fard

    2015-06-01

    Full Text Available Evaluation of the reliability parameters in micro-grids based on renewable energy sources is one of the main problems that are investigated in this paper. Renewable energy sources such as solar and wind energy, battery as an energy storage system and fuel cell as a backup system are used to provide power to the electrical loads of the micro-grid. Loads in the micro-grid consist of interruptible and uninterruptible loads. In addition to the reliability parameters, Forced Outage Rate of each component and also uncertainty of wind power, PV power and demand are considered for micro-grid. In this paper, the problem is formulated as a nonlinear integer minimization problem which minimizes the sum of the total capital, operational, maintenance and replacement cost of DERs. This paper proposes PSO for solving this minimization problem.

  18. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  19. Applying data mining techniques to determine important parameters in chronic kidney disease and the relations of these parameters to each other.

    Science.gov (United States)

    Tahmasebian, Shahram; Ghazisaeedi, Marjan; Langarizadeh, Mostafa; Mokhtaran, Mehrshad; Mahdavi-Mazdeh, Mitra; Javadian, Parisa

    2017-01-01

    Introduction: Chronic kidney disease (CKD) includes a wide range of pathophysiological processes which will be observed along with abnormal function of kidneys and progressive decrease in glomerular filtration rate (GFR). According to the definition decreasing GFR must have been present for at least three months. CKD will eventually result in end-stage kidney disease. In this process different factors play role and finding the relations between effective parameters in this regard can help to prevent or slow progression of this disease. There are always a lot of data being collected from the patients' medical records. This huge array of data can be considered a valuable source for analyzing, exploring and discovering information. Objectives: Using the data mining techniques, the present study tries to specify the effective parameters and also aims to determine their relations with each other in Iranian patients with CKD. Material and Methods: The study population includes 31996 patients with CKD. First, all of the data is registered in the database. Then data mining tools were used to find the hidden rules and relationships between parameters in collected data. Results: After data cleaning based on CRISP-DM (Cross Industry Standard Process for Data Mining) methodology and running mining algorithms on the data in the database the relationships between the effective parameters was specified. Conclusion: This study was done using the data mining method pertaining to the effective factors on patients with CKD.

  20. Meta-analysis on Methane Mitigating Properties of Saponin-rich Sources in the Rumen: Influence of Addition Levels and Plant Sources

    Directory of Open Access Journals (Sweden)

    Anuraga Jayanegara

    2014-10-01

    Full Text Available Saponins have been considered as promising natural substances for mitigating methane emissions from ruminants. However, studies reported that addition of saponin-rich sources often arrived at contrasting results, i.e. either it decreased methane or it did not. The aim of the present study was to assess ruminal methane emissions through a meta-analytical approach of integrating related studies from published papers which described various levels of different saponin-rich sources being added to ruminant feed. A database was constructed from published literature reporting the addition of saponin-rich sources at various levels and then monitoring ruminal methane emissions in vitro. Accordingly, levels of saponin-rich source additions as well as different saponin sources were specified in the database. Apart from methane, other related rumen fermentation parameters were also included in the database, i.e. organic matter digestibility, gas production, pH, ammonia concentration, short-chain fatty acid profiles and protozoal count. A total of 23 studies comprised of 89 data points met the inclusion criteria. The data obtained were subsequently subjected to a statistical meta-analysis based on mixed model methodology. Accordingly, different studies were treated as random effects whereas levels of saponin-rich source additions or different saponin sources were considered as fixed effects. Model statistics used were p-value and root mean square error. Results showed that an addition of increasing levels of a saponin-rich source decreased methane emission per unit of substrate incubated as well as per unit of total gas produced (ptea>quillaja, statistically they did not differ each other. It can be concluded that methane mitigating properties of saponins in the rumen are level- and source-dependent.

  1. Study of some physiological parameters among mobile phone users

    International Nuclear Information System (INIS)

    Anwar, S.M.; Gabr, S.A.

    2002-01-01

    Forty male mobile users in additional to twenty males as control group similar in age and socio economically matched were chosen for this study. Blood pressure, complete blood picture, five parameters of semen quality and four sex hormones (LH, FSH, prolactin and testosterone)were measured. Elevated significant differences for blood pressure (P<0.01) for the exposed group and some changes in mean values of haematologic parameters, although all values were within the normal range. Minor semen quality and hormonal levels changes between the two groups, including a higher mean follicle-stimulating hormone level; for mobile users (8.10 vs 6.00 mIU/mL), and a slightly higher mean luteinizing hormone level (11.73 vs 10.16 mLU/mL) were noted in the user group

  2. Delayed recombination and cosmic parameters

    International Nuclear Information System (INIS)

    Galli, Silvia; Melchiorri, Alessandro; Bean, Rachel; Silk, Joseph

    2008-01-01

    Current cosmological constraints from cosmic microwave background anisotropies are typically derived assuming a standard recombination scheme, however additional resonance and ionizing radiation sources can delay recombination, altering the cosmic ionization history and the cosmological inferences drawn from the cosmic microwave background data. We show that for recent observations of the cosmic microwave background anisotropy, from the Wilkinson microwave anisotropy probe satellite mission (WMAP) 5-year survey and from the arcminute cosmology bolometer array receiver experiment, additional resonance radiation is nearly degenerate with variations in the spectral index, n s , and has a marked effect on uncertainties in constraints on the Hubble constant, age of the universe, curvature and the upper bound on the neutrino mass. When a modified recombination scheme is considered, the redshift of recombination is constrained to z * =1078±11, with uncertainties in the measurement weaker by 1 order of magnitude than those obtained under the assumption of standard recombination while constraints on the shift parameter are shifted by 1σ to R=1.734±0.028. From the WMAP5 data we obtain the following constraints on the resonance and ionization sources parameters: ε α i <0.058 at 95% c.l.. Although delayed recombination limits the precision of parameter estimation from the WMAP satellite, we demonstrate that this should not be the case for future, smaller angular scales measurements, such as those by the Planck satellite mission.

  3. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  4. Studies on the method of producing radiographic 170Tm source

    International Nuclear Information System (INIS)

    Maeda, Sho

    1976-08-01

    A method of producing radiographic 170 Tm source has been studied, including target preparation, neutron irradiation, handling of the irradiated target in the hot cell and source capsules. On the basis of the results, practical 170 Tm radiographic sources (29 -- 49Ci, with pellets 3mm in diameter and 3mm long) were produced in trial by neutron irradiation with the JMTR. (auth.)

  5. Algorithm sensitivity analysis and parameter tuning for tissue image segmentation pipelines

    Science.gov (United States)

    Kurç, Tahsin M.; Taveira, Luís F. R.; Melo, Alba C. M. A.; Gao, Yi; Kong, Jun; Saltz, Joel H.

    2017-01-01

    Abstract Motivation: Sensitivity analysis and parameter tuning are important processes in large-scale image analysis. They are very costly because the image analysis workflows are required to be executed several times to systematically correlate output variations with parameter changes or to tune parameters. An integrated solution with minimum user interaction that uses effective methodologies and high performance computing is required to scale these studies to large imaging datasets and expensive analysis workflows. Results: The experiments with two segmentation workflows show that the proposed approach can (i) quickly identify and prune parameters that are non-influential; (ii) search a small fraction (about 100 points) of the parameter search space with billions to trillions of points and improve the quality of segmentation results (Dice and Jaccard metrics) by as much as 1.42× compared to the results from the default parameters; (iii) attain good scalability on a high performance cluster with several effective optimizations. Conclusions: Our work demonstrates the feasibility of performing sensitivity analyses, parameter studies and auto-tuning with large datasets. The proposed framework can enable the quantification of error estimations and output variations in image segmentation pipelines. Availability and Implementation: Source code: https://github.com/SBU-BMI/region-templates/. Contact: teodoro@unb.br Supplementary information: Supplementary data are available at Bioinformatics online. PMID:28062445

  6. Application and optimization of input parameter spaces in mass flow modelling: a case study with r.randomwalk and r.ranger

    Science.gov (United States)

    Krenn, Julia; Zangerl, Christian; Mergili, Martin

    2017-04-01

    r.randomwalk is a GIS-based, multi-functional, conceptual open source model application for forward and backward analyses of the propagation of mass flows. It relies on a set of empirically derived, uncertain input parameters. In contrast to many other tools, r.randomwalk accepts input parameter ranges (or, in case of two or more parameters, spaces) in order to directly account for these uncertainties. Parameter spaces represent a possibility to withdraw from discrete input values which in most cases are likely to be off target. r.randomwalk automatically performs multiple calculations with various parameter combinations in a given parameter space, resulting in the impact indicator index (III) which denotes the fraction of parameter value combinations predicting an impact on a given pixel. Still, there is a need to constrain the parameter space used for a certain process type or magnitude prior to performing forward calculations. This can be done by optimizing the parameter space in terms of bringing the model results in line with well-documented past events. As most existing parameter optimization algorithms are designed for discrete values rather than for ranges or spaces, the necessity for a new and innovative technique arises. The present study aims at developing such a technique and at applying it to derive guiding parameter spaces for the forward calculation of rock avalanches through back-calculation of multiple events. In order to automatize the work flow we have designed r.ranger, an optimization and sensitivity analysis tool for parameter spaces which can be directly coupled to r.randomwalk. With r.ranger we apply a nested approach where the total value range of each parameter is divided into various levels of subranges. All possible combinations of subranges of all parameters are tested for the performance of the associated pattern of III. Performance indicators are the area under the ROC curve (AUROC) and the factor of conservativeness (FoC). This

  7. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding...

  8. Thermal-Hydraulic Sensitivity Study of Intermediate Loop Parameters for Nuclear Hydrogen Production System

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Hwa; Lee, Heung Nae; Park, Jea Ho [KONES Corp., Seoul (Korea, Republic of); Lee, Won Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Sang Il; Yoo, Yeon Jae [Hyundai Engineering Co., Seoul (Korea, Republic of)

    2016-10-15

    The heat generated from the VHTR is transferred to the intermediate loop through Intermediate Heat Exchanger (IHX). It is further passed on to the Sulfur-Iodine (SI) hydrogen production system (HPS) through Process Heat Exchanger (PHX). The IL provides the safety distance between the VHTR and HPS. Since the IL performance affects the overall nuclear HPS efficiency, it is required to optimize its design and operation parameters. In this study, the thermal-hydraulic sensitivity of IL parameters with various coolant options has been examined by using MARS-GCR code, which was already applied for the case of steam generator. Sensitivity study of the IL and PHX parameters has been carried out based on their thermal-hydraulic performance. Several parameters for design and operation, such as the pipe diameter, safety distance and surface area, are considered for different coolant options, He, CO{sub 2} and He-CO{sub 2} (2:8). It was found that the circulator work is the major factor affecting on the overall nuclear hydrogen production system efficiency. Circulator work increases with the safety distance, and decreases with the operation pressure and loop pipe diameter. Sensitivity results obtained from this study will contribute to the optimization of the IL design and operation parameters and the optimal coolant selection.

  9. Study on Parameters Modeling of Wind Turbines Using SCADA Data

    Directory of Open Access Journals (Sweden)

    Yonglong YAN

    2014-08-01

    Full Text Available Taking the advantage of the current massive monitoring data from Supervisory Control and Data Acquisition (SCADA system of wind farm, it is of important significance for anomaly detection, early warning and fault diagnosis to build the data model of state parameters of wind turbines (WTs. The operational conditions and the relationships between the state parameters of wind turbines are complex. It is difficult to establish the model of state parameter accurately, and the modeling method of state parameters of wind turbines considering parameter selection is proposed. Firstly, by analyzing the characteristic of SCADA data, a reasonable range of data and monitoring parameters are chosen. Secondly, neural network algorithm is adapted, and the selection method of input parameters in the model is presented. Generator bearing temperature and cooling air temperature are regarded as target parameters, and the two models are built and input parameters of the models are selected, respectively. Finally, the parameter selection method in this paper and the method using genetic algorithm-partial least square (GA-PLS are analyzed comparatively, and the results show that the proposed methods are correct and effective. Furthermore, the modeling of two parameters illustrate that the method in this paper can applied to other state parameters of wind turbines.

  10. Prosecutor: parameter-free inference of gene function for prokaryotes using DNA microarray data, genomic context and multiple gene annotation sources

    Directory of Open Access Journals (Sweden)

    van Hijum Sacha AFT

    2008-10-01

    Full Text Available Abstract Background Despite a plethora of functional genomic efforts, the function of many genes in sequenced genomes remains unknown. The increasing amount of microarray data for many species allows employing the guilt-by-association principle to predict function on a large scale: genes exhibiting similar expression patterns are more likely to participate in shared biological processes. Results We developed Prosecutor, an application that enables researchers to rapidly infer gene function based on available gene expression data and functional annotations. Our parameter-free functional prediction method uses a sensitive algorithm to achieve a high association rate of linking genes with unknown function to annotated genes. Furthermore, Prosecutor utilizes additional biological information such as genomic context and known regulatory mechanisms that are specific for prokaryotes. We analyzed publicly available transcriptome data sets and used literature sources to validate putative functions suggested by Prosecutor. We supply the complete results of our analysis for 11 prokaryotic organisms on a dedicated website. Conclusion The Prosecutor software and supplementary datasets available at http://www.prosecutor.nl allow researchers working on any of the analyzed organisms to quickly identify the putative functions of their genes of interest. A de novo analysis allows new organisms to be studied.

  11. Post-processing of Monte Carlo simulations for rapid BNCT source optimization studies

    International Nuclear Information System (INIS)

    Bleuel, D.L.; Chu, W.T.; Donahue, R.J.; Ludewigt, B.A.; Vujic, J.

    2000-01-01

    A great advantage of some neutron sources, such as accelerator-produced sources, is that they can be tuned to produce different spectra. Unfortunately, optimization studies are often time-consuming and difficult, as they require a lengthy Monte Carlo simulation for each source. When multiple characteristics, such as energy, angle, and spatial distribution of a neutron beam are allowed to vary, an overwhelming number of simulations may be required. Many optimization studies, therefore, suffer from a small number of datapoints, restrictive treatment conditions, or poor statistics. By scoring pertinent information from every particle tally in a Monte Carlo simulation, then applying appropriate source variable weight factors in a post-processing algorithm, a single simulation can be used to model any number of multiple sources. Through this method, the response to a new source can be modeled in minutes or seconds, rather than hours or days, allowing for the analysis of truly variable source conditions of much greater resolution than is normally possible when a new simulation must be run for each datapoint in a study. This method has been benchmarked and used to recreate optimization studies in a small fraction of the time spent in the original studies

  12. OpenMC In Situ Source Convergence Detection

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Garrett Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Univ. of California, Davis, CA (United States); Dutta, Soumya [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); The Ohio State Univ., Columbus, OH (United States); Woodring, Jonathan Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-07

    We designed and implemented an in situ version of particle source convergence for the OpenMC particle transport simulator. OpenMC is a Monte Carlo based-particle simulator for neutron criticality calculations. For the transport simulation to be accurate, source particles must converge on a spatial distribution. Typically, convergence is obtained by iterating the simulation by a user-settable, fixed number of steps, and it is assumed that convergence is achieved. We instead implement a method to detect convergence, using the stochastic oscillator for identifying convergence of source particles based on their accumulated Shannon Entropy. Using our in situ convergence detection, we are able to detect and begin tallying results for the full simulation once the proper source distribution has been confirmed. Our method ensures that the simulation is not started too early, by a user setting too optimistic parameters, or too late, by setting too conservative a parameter.

  13. Variations in environmental tritium doses due to meteorological data averaging and uncertainties in pathway model parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kock, A.

    1996-05-01

    The objectives of this research are: (1) to calculate and compare off site doses from atmospheric tritium releases at the Savannah River Site using monthly versus 5 year meteorological data and annual source terms, including additional seasonal and site specific parameters not included in present annual assessments; and (2) to calculate the range of the above dose estimates based on distributions in model parameters given by uncertainty estimates found in the literature. Consideration will be given to the sensitivity of parameters given in former studies.

  14. Variations in environmental tritium doses due to meteorological data averaging and uncertainties in pathway model parameters

    International Nuclear Information System (INIS)

    Kock, A.

    1996-05-01

    The objectives of this research are: (1) to calculate and compare off site doses from atmospheric tritium releases at the Savannah River Site using monthly versus 5 year meteorological data and annual source terms, including additional seasonal and site specific parameters not included in present annual assessments; and (2) to calculate the range of the above dose estimates based on distributions in model parameters given by uncertainty estimates found in the literature. Consideration will be given to the sensitivity of parameters given in former studies

  15. Ion source of discharge type

    Energy Technology Data Exchange (ETDEWEB)

    Enchevich, I.B. [TRIUMF, Cyclotron Div., Vancouver, British Columbia (Canada); Korenev, S.A. [JINR, Hihg Energy Physics Lab., Dubna, Moscow (Russian Federation)

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm{sup 2}; ions of Cl, F, C, H; residual gas pressure P = 10{sup -6} Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  16. Ion source of discharge type

    International Nuclear Information System (INIS)

    Enchevich, I.B.; Korenev, S.A.

    1992-07-01

    A new scheme of ion source based on a dielectric surface sliding discharge is described. The conditions to form this type of discharge are analyzed and experimental results are shown. The main parameters of this ion source are: accelerating voltage U = 1/20kV; continuous extracted ion beam; current density j = 0.01/0.5 A/cm 2 ; ions of Cl, F, C, H; residual gas pressure P = 10 -6 Torr. A magnetic system is used to separate the different types of ions. The dielectric material in the discharge circuit (anode plasma emitter) defines the type of ions. The emission characteristics of plasma emitter and the discharge parameters are presented. The ion current yield satisfies the Child-Langmuir law. (author)

  17. Comparison between Different Power Sources for Emergency Power Supply at Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lenasson, Magnus

    2015-01-01

    report is financed by Elforsk - Swedish Electrical Utilities' R and D Company. The background of the report is that the Fukushima accident showed how redundant but not diversified power sources can be destroyed by external events. This might lead to increased focus on diversification, from the industry and/or the regulating authorities. A number of essential parameters for a power source to work as emergency power supply at a nuclear power plant have been identified; ten different power sources have then been evaluated with respect to these parameters. The report is supposed to work as a knowledge base and decision support when new nuclear power plants or reinvestments in old ones are considered. The studied power sources are: Diesel generators, Gas turbines, Internal steam turbines, Externals steam turbines, Hydro power plant, Batteries, Fuel cells, Stirling engines, Thermoelectric elements, Flywheels. The power sources are evaluated for five different applications, each application with its own acceptance criteria for each of the essential parameters. The five applications are: Onsite emergency AC source, Onsite emergency DC source, Alternate AC source, small, Alternate AC source, large, Alternate AC source, mobile. Mainly Swedish preconditions are considered in the report, but most of the results are applicable in any other country. (author)

  18. Sex determination of human mandible using metrical parameters by computed tomography: A prospective radiographic short study

    Directory of Open Access Journals (Sweden)

    Basavaraj N Kallalli

    2016-01-01

    Full Text Available Introduction: Sex determination of unidentified human remains is very important in forensic medicine, medicolegal cases, and forensic anthropology. The mandible is the largest and hardest facial bone that commonly resists postmortem damage and forms an important source of personal identification. Additional studies have demonstrated the applicability of facial reconstruction using three-dimensional computed tomography scan (3D-CT for the purpose of individual identification. Aim: To determine the sex of human mandible using metrical parameters by CT. Materials and Methods: The study included thirty subjects (15 males and 15 females, with age group ranging between 10 and 60 years obtained from the outpatient department of Oral Medicine and Radiology, Narsinhbhai Patel Dental College and Hospital. CT scan was performed on all the subjects, and the data obtained were reconstructed for 3D viewing. After obtaining 3D-CT scan, a total of seven mandibular measurements, i.e., gonial angle (G-angle, ramus length (Ramus-L, minimum ramus breadth and gonion-gnathion length (G-G-L, bigonial breadth, bicondylar breadth (BIC-Br, and coronoid length (CO-L were measured; collected data were analyzed using SPSS statistical analysis program by Student's t-test. Results: The result of the study showed that out of seven parameters, G-angle, Ramus-L, G-G-L, BIC-Br, and CO-L showed a significant statistical difference (P < 0.05, with overall accuracy of 86% for males and 82% for females. Conclusion: Personal identification using mandible by conventional methods has already been proved but with variable efficacies. Advanced imaging modalities can aid in personal identification with much higher accuracy than conventional methods.

  19. Chemometric expertise of the quality of groundwater sources for domestic use.

    Science.gov (United States)

    Spanos, Thomas; Ene, Antoaneta; Simeonova, Pavlina

    2015-01-01

    In the present study 49 representative sites have been selected for the collection of water samples from central water supplies with different geographical locations in the region of Kavala, Northern Greece. Ten physicochemical parameters (pH, electric conductivity, nitrate, chloride, sodium, potassium, total alkalinity, total hardness, bicarbonate and calcium) were analyzed monthly, in the period from January 2010 to December 2010. Chemometric methods were used for monitoring data mining and interpretation (cluster analysis, principal components analysis and source apportioning by principal components regression). The clustering of the chemical indicators delivers two major clusters related to the water hardness and the mineral components (impacted by sea, bedrock and acidity factors). The sampling locations are separated into three major clusters corresponding to the spatial distribution of the sites - coastal, lowland and semi-mountainous. The principal components analysis reveals two latent factors responsible for the data structures, which are also an indication for the sources determining the groundwater quality of the region (conditionally named "mineral" factor and "water hardness" factor). By the apportionment approach it is shown what the contribution is of each of the identified sources to the formation of the total concentration of each one of the chemical parameters. The mean values of the studied physicochemical parameters were found to be within the limits given in the 98/83/EC Directive. The water samples are appropriate for human consumption. The results of this study provide an overview of the hydrogeological profile of water supply system for the studied area.

  20. Investigations of incorporating source directivity into room acoustics computer models to improve auralizations

    Science.gov (United States)

    Vigeant, Michelle C.

    Room acoustics computer modeling and auralizations are useful tools when designing or modifying acoustically sensitive spaces. In this dissertation, the input parameter of source directivity has been studied in great detail to determine first its effect in room acoustics computer models and secondly how to better incorporate the directional source characteristics into these models to improve auralizations. To increase the accuracy of room acoustics computer models, the source directivity of real sources, such as musical instruments, must be included in the models. The traditional method for incorporating source directivity into room acoustics computer models involves inputting the measured static directivity data taken every 10° in a sphere-shaped pattern around the source. This data can be entered into the room acoustics software to create a directivity balloon, which is used in the ray tracing algorithm to simulate the room impulse response. The first study in this dissertation shows that using directional sources over an omni-directional source in room acoustics computer models produces significant differences both in terms of calculated room acoustics parameters and auralizations. The room acoustics computer model was also validated in terms of accurately incorporating the input source directivity. A recently proposed technique for creating auralizations using a multi-channel source representation has been investigated with numerous subjective studies, applied to both solo instruments and an orchestra. The method of multi-channel auralizations involves obtaining multi-channel anechoic recordings of short melodies from various instruments and creating individual channel auralizations. These auralizations are then combined to create a total multi-channel auralization. Through many subjective studies, this process was shown to be effective in terms of improving the realism and source width of the auralizations in a number of cases, and also modeling different

  1. A New Source Biasing Approach in ADVANTG

    International Nuclear Information System (INIS)

    Bevill, Aaron M.; Mosher, Scott W.

    2012-01-01

    The ADVANTG code has been developed at Oak Ridge National Laboratory to generate biased sources and weight window maps for MCNP using the CADIS and FW-CADIS methods. In preparation for an upcoming RSICC release, a new approach for generating a biased source has been developed. This improvement streamlines user input and improves reliability. Previous versions of ADVANTG generated the biased source from ADVANTG input, writing an entirely new general fixed-source definition (SDEF). Because volumetric sources were translated into SDEF-format as a finite set of points, the user had to perform a convergence study to determine whether the number of source points used accurately represented the source region. Further, the large number of points that must be written in SDEF-format made the MCNP input and output files excessively long and difficult to debug. ADVANTG now reads SDEF-format distributions and generates corresponding source biasing cards, eliminating the need for a convergence study. Many problems of interest use complicated source regions that are defined using cell rejection. In cell rejection, the source distribution in space is defined using an arbitrarily complex cell and a simple bounding region. Source positions are sampled within the bounding region but accepted only if they fall within the cell; otherwise, the position is resampled entirely. When biasing in space is applied to sources that use rejection sampling, current versions of MCNP do not account for the rejection in setting the source weight of histories, resulting in an 'unfair game'. This problem was circumvented in previous versions of ADVANTG by translating volumetric sources into a finite set of points, which does not alter the mean history weight ((bar w)). To use biasing parameters without otherwise modifying the original cell-rejection SDEF-format source, ADVANTG users now apply a correction factor for (bar w) in post-processing. A stratified-random sampling approach in ADVANTG is under

  2. Cord blood full blood count parameters in Lagos, Nigeria | Adewumi ...

    African Journals Online (AJOL)

    Due to its usefulness in the assessment of health status of individuals, its parameters in cord blood, a major source of haemopoietic stem cell transplantation and an ideal source for laboratory investigations for newborns were determined to provide a useful guide to local neonatologists and stem cell transplant physicians.

  3. Parameter motivated mutual correlation analysis: Application to the study of currency exchange rates based on intermittency parameter and Hurst exponent

    Science.gov (United States)

    Cristescu, Constantin P.; Stan, Cristina; Scarlat, Eugen I.; Minea, Teofil; Cristescu, Cristina M.

    2012-04-01

    We present a novel method for the parameter oriented analysis of mutual correlation between independent time series or between equivalent structures such as ordered data sets. The proposed method is based on the sliding window technique, defines a new type of correlation measure and can be applied to time series from all domains of science and technology, experimental or simulated. A specific parameter that can characterize the time series is computed for each window and a cross correlation analysis is carried out on the set of values obtained for the time series under investigation. We apply this method to the study of some currency daily exchange rates from the point of view of the Hurst exponent and the intermittency parameter. Interesting correlation relationships are revealed and a tentative crisis prediction is presented.

  4. Total and fission cross-sections of 239Pu - statistical study of resonance parameters

    International Nuclear Information System (INIS)

    Derrien, H.; Blons, J.; Eggermann, C.; Michaudon, A.; Paya, D.; Ribon, P.

    1967-01-01

    The authors measured the total and fission cross-sections of 239 Pu with the linear accelerator at Saclay as a pulsed source of neutrons. The total cross-section was measured in the range from 4 to 700 eV and the best resolution used was 1.5 ns/m; the fission cross-section was measured between 4 eV and 6 keV, the best resolution having been 6 ns/m. The transmission measurements on five samples were made at the temperature of liquid nitrogen, and comparisons made with supplementary experiments at ambient temperature made it possible to determine the Doppler broadening factor (Δ = η√E). The resonances were identified from 4 to 500 eV in the total cross-section; the average level spacing was of the order of 2.4 eV. It would appear that, in this energy range, nearly all the levels were identified. The resonance parameters were determined by analysis of shape in conjunction with a least-squares programme on an IBM-7094 computer. The existence of a large number of broad resonances corresponding to very large fission widths has been shown to exist. Statistical study of the fission widths actually shows the existence of two families of resonances, one corresponding to a mean Γ f of the order of 45 meV and the other to a mean Γ/f of about 750 meV. The authors were therefore able to postulate a classification of resonances in terms of two spin states, the level population ratio in each family being: (2J 1 +1)/(2J 2 +1) = 1/3; J 1 = 0 corresponds to the broad resonances and J 2 = 1 to the narrow ones. The partial widths for radiative capture fluctuate slightly around a mean value of 40 meV. By using a multilevel programme, the authors were able to investigate the extent to which the existence of large fission widths might give rise to fictitious resonances (quasi-resonances) and perturbations and also to make a statistical study of the resonance parameters. (author) [fr

  5. Effect of anapanasati meditation technique through electrophotonic imaging parameters: A pilot study.

    Science.gov (United States)

    Deo, Guru; Itagi R, Kumar; Thaiyar M, Srinivasan; Kuldeep, Kushwah K

    2015-01-01

    Mindfulness along with breathing is a well-established meditation technique. Breathing is an exquisite tool for exploring subtle awareness of mind and life itself. This study aimed at measuring changes in the different parameters of electrophotonic imaging (EPI) in anapanasati meditators. To carry out this study, 51 subjects comprising 32 males and 19 females of age 18 years and above (mean age 45.64 ± 14.43) were recruited voluntarily with informed consent attending Karnataka Dhyana Mahachakra-1 at Pyramid Valley International, Bengaluru, India. The design was a single group pre- post and data collected by EPI device before and after 5 days of intensive meditation. Results show significant changes in EPI parameter integral area with filter (physiological) in both right and left side, which reflects the availability of high functional energy reserve in meditators. The researchers observed similar trends without filter (psycho-physiological) indicating high reserves of energy at psycho-physiological level also. Activation coefficient, another parameter of EPI, reduced showing more relaxed state than earlier, possibly due to parasympathetic dominance. Integral entropy decreased in the case of psycho-physiological parameters left-side without filter, which indicates less disorder after meditation, but these changes were not significant. The study showed a reversed change in integral entropy in the right side without filter; however, the values on both sides with filter increased, which indicates disorder. The study suggests that EPI can be used in the recording functional physiological and psychophysiological status of meditators at a subtle level.

  6. EX VIVO STUDY OF QUANTITATIVE ULTRASOUND PARAMETERS IN FATTY RABBIT LIVERS

    Science.gov (United States)

    Ghoshal, Goutam; Lavarello, Roberto J.; Kemmerer, Jeremy P.; Miller, Rita J.; Oelze, Michael L.

    2012-01-01

    Nonalcoholic fatty liver disease (NAFLD) affects more than 30% of Americans, and with increasing problems of obesity in the United States, NAFLD is poised to become an even more serious medical concern. At present, accurate classification of steatosis (fatty liver) represents a significant challenge. In this study, the use of high-frequency (8 to 25 MHz) quantitative ultrasound (QUS) imaging to quantify fatty liver was explored. QUS is an imaging technique that can be used to quantify properties of tissue giving rise to scattered ultrasound. The changes in the ultrasound properties of livers in rabbits undergoing atherogenic diets of varying durations were investigated using QUS. Rabbits were placed on a special fatty diet for 0, 3, or 6 weeks. The fattiness of the livers was quantified by estimating the total lipid content of the livers. Ultrasonic properties, such as speed of sound, attenuation, and backscatter coefficients, were estimated in ex vivo rabbit liver samples from animals that had been on the diet for varying periods. Two QUS parameters were estimated based on the backscatter coefficient: effective scatterer diameter (ESD) and effective acoustic concentration (EAC), using a spherical Gaussian scattering model. Two parameters were estimated based on the backscattered envelope statistics (the k parameter and the μ parameter) according to the homodyned K distribution. The speed of sound decreased from 1574 to 1565 m/s and the attenuation coefficient increased from 0.71 to 1.27 dB/cm/MHz, respectively, with increasing fat content in the liver. The ESD decreased from 31 to 17 μm and the EAC increased from 38 to 63 dB/cm3 with increasing fat content in the liver. A significant increase in the μ parameter from 0.18 to 0.93 scatterers/mm3 was observed with increasing fat content in the liver samples. The results of this study indicate that QUS parameters are sensitive to fat content in the liver. PMID:23062376

  7. Reference tissue modeling with parameter coupling: application to a study of SERT binding in HIV

    Energy Technology Data Exchange (ETDEWEB)

    Endres, Christopher J; Pomper, Martin G [Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, MD 21231 (United States); Hammoud, Dima A, E-mail: endres@jhmi.edu [Radiology and Imaging Sciences, National Institutes of Health/Clinical Center, Bethesda, MD (United States)

    2011-04-21

    When applicable, it is generally preferred to evaluate positron emission tomography (PET) studies using a reference tissue-based approach as that avoids the need for invasive arterial blood sampling. However, most reference tissue methods have been shown to have a bias that is dependent on the level of tracer binding, and the variability of parameter estimates may be substantially affected by noise level. In a study of serotonin transporter (SERT) binding in HIV dementia, it was determined that applying parameter coupling to the simplified reference tissue model (SRTM) reduced the variability of parameter estimates and yielded the strongest between-group significant differences in SERT binding. The use of parameter coupling makes the application of SRTM more consistent with conventional blood input models and reduces the total number of fitted parameters, thus should yield more robust parameter estimates. Here, we provide a detailed evaluation of the application of parameter constraint and parameter coupling to [{sup 11}C]DASB PET studies. Five quantitative methods, including three methods that constrain the reference tissue clearance (k{sup r}{sub 2}) to a common value across regions were applied to the clinical and simulated data to compare measurement of the tracer binding potential (BP{sub ND}). Compared with standard SRTM, either coupling of k{sup r}{sub 2} across regions or constraining k{sup r}{sub 2} to a first-pass estimate improved the sensitivity of SRTM to measuring a significant difference in BP{sub ND} between patients and controls. Parameter coupling was particularly effective in reducing the variance of parameter estimates, which was less than 50% of the variance obtained with standard SRTM. A linear approach was also improved when constraining k{sup r}{sub 2} to a first-pass estimate, although the SRTM-based methods yielded stronger significant differences when applied to the clinical study. This work shows that parameter coupling reduces the

  8. A new tool for rapid and automatic estimation of earthquake source parameters and generation of seismic bulletins

    Science.gov (United States)

    Zollo, Aldo

    2016-04-01

    RISS S.r.l. is a Spin-off company recently born from the initiative of the research group constituting the Seismology Laboratory of the Department of Physics of the University of Naples Federico II. RISS is an innovative start-up, based on the decade-long experience in earthquake monitoring systems and seismic data analysis of its members and has the major goal to transform the most recent innovations of the scientific research into technological products and prototypes. With this aim, RISS has recently started the development of a new software, which is an elegant solution to manage and analyse seismic data and to create automatic earthquake bulletins. The software has been initially developed to manage data recorded at the ISNet network (Irpinia Seismic Network), which is a network of seismic stations deployed in Southern Apennines along the active fault system responsible for the 1980, November 23, MS 6.9 Irpinia earthquake. The software, however, is fully exportable and can be used to manage data from different networks, with any kind of station geometry or network configuration and is able to provide reliable estimates of earthquake source parameters, whichever is the background seismicity level of the area of interest. Here we present the real-time automated procedures and the analyses performed by the software package, which is essentially a chain of different modules, each of them aimed at the automatic computation of a specific source parameter. The P-wave arrival times are first detected on the real-time streaming of data and then the software performs the phase association and earthquake binding. As soon as an event is automatically detected by the binder, the earthquake location coordinates and the origin time are rapidly estimated, using a probabilistic, non-linear, exploration algorithm. Then, the software is able to automatically provide three different magnitude estimates. First, the local magnitude (Ml) is computed, using the peak-to-peak amplitude

  9. Experimental study on effect of hydroalcoholic extract of Emblica officinalis fruits on glucose homeostasis and metabolic parameters

    Science.gov (United States)

    Patel, Snehal S.; Goyal, Ramesh K.; Shah, Rajendra S.; Tirgar, Pravin R.; Jadav, Pinakin D.

    2013-01-01

    Polyphenols from natural source are potential therapeutics that act alone or supplement anti-diabetic drugs in the prevention and treatment of diabetes. The present investigation was undertaken to study the effect of hydroalcoholic extract (HE) of fruits of Emblica officinalis on type 1 diabetic rats. Diabetes was induced by streptozotocin (STZ) (45 mg/kg i.v.). HE (100 mg/kg, p.o.) was administered for 4 weeks and at the end of treatment, blood samples were collected and analyzed for various biochemical parameters. STZ produced a diabetic state exhibiting all the cardinal symptoms such as loss of body weight, polydipsia, polyuria, glucosuria, polyphagia, hypoinsulinemia, and hyperglycemia associated with hypercholesterolemia and hypertriglyceridemia. Treatment with HE prevented cardinal symptoms and caused significant decrease in fasting serum glucose, AUCglucose, cholesterol, triglyceride, low-density lipoprotein (LDL) and very LDL in diabetic rats. However, insulin, AUCinsulin, and serum high-density lipoprotein level were not significantly altered by treatment. Treatment also reduced lipid peroxidation and increased anti-oxidant parameters in the liver homogenates of diabetic rats. Polyphenol enriched fraction of HE significantly improved disarranged carbohydrate and lipid metabolism of chemically induced diabetes in rats. The mechanism of its anti-diabetic activity appears to be either improvement in peripheral glucose utilization, increased insulin sensitivity, or anti-oxidant property. PMID:24696584

  10. Probabilistic forward model for electroencephalography source analysis

    International Nuclear Information System (INIS)

    Plis, Sergey M; George, John S; Jun, Sung C; Ranken, Doug M; Volegov, Petr L; Schmidt, David M

    2007-01-01

    Source localization by electroencephalography (EEG) requires an accurate model of head geometry and tissue conductivity. The estimation of source time courses from EEG or from EEG in conjunction with magnetoencephalography (MEG) requires a forward model consistent with true activity for the best outcome. Although MRI provides an excellent description of soft tissue anatomy, a high resolution model of the skull (the dominant resistive component of the head) requires CT, which is not justified for routine physiological studies. Although a number of techniques have been employed to estimate tissue conductivity, no present techniques provide the noninvasive 3D tomographic mapping of conductivity that would be desirable. We introduce a formalism for probabilistic forward modeling that allows the propagation of uncertainties in model parameters into possible errors in source localization. We consider uncertainties in the conductivity profile of the skull, but the approach is general and can be extended to other kinds of uncertainties in the forward model. We and others have previously suggested the possibility of extracting conductivity of the skull from measured electroencephalography data by simultaneously optimizing over dipole parameters and the conductivity values required by the forward model. Using Cramer-Rao bounds, we demonstrate that this approach does not improve localization results nor does it produce reliable conductivity estimates. We conclude that the conductivity of the skull has to be either accurately measured by an independent technique, or that the uncertainties in the conductivity values should be reflected in uncertainty in the source location estimates

  11. Sources of Strategic Information in Farm Management in Poland. Study Results

    Directory of Open Access Journals (Sweden)

    Jacek Jaworski

    2017-03-01

    Full Text Available Purposes: The main goal of the paper is to determine the signifcance of selected sources of strategic information, used by Polish farmers in decision making. In addition, an attempt was made to determine the factors impacting the evaluation of those sources among the traits of the farmer and his farm. Methodology: Data was gathered using the questionnaire method and analysed with standard tools of descriptive statistics. Findings: The farmers deemed personalised sources of strategic information the most important, especially agricultural advisers, input suppliers and buyers of agricultural products. From among institutional (non-personalised sources, local government and the chamber of agriculture were signifcant. Business information agencies and survey companies are the least important sources for farmers. The characteristics of the surroundings of the farm – specifcally, its geographic location and the size of settlement where it is located proved to have the widest impact on the evaluation of the sources included in the study. From among the organisational factors, only farm size has a signifcant impact. Research limitations/implications: The study was confned to a representative group of farmers in Poland. A closed list of sources of strategic information was used. Originality/value: The study results contribute to the knowledge on the functioning of Polish agriculture and may also be used in comparative studies, characterising this sector’s diversity within Europe. They can in turn contribute to properly focusing on supporting the policy of balanced agriculture development in the EU.

  12. Sources of dispersion in industrial radiography

    International Nuclear Information System (INIS)

    Ruault, P.A.

    1985-01-01

    Maximum value of divergence produced by the different parameters are summed up. Parameters examined include the emulsion (aging, processing), the source (filtration, energy, angle), the dosimetry, the object and the print. In the case of testing in the same conditions errors are relatively low but for testing the same object after a long time errors can be important [fr

  13. Viscoelastic Fluid over a Stretching Sheet with Electromagnetic Effects and Nonuniform Heat Source/Sink

    Directory of Open Access Journals (Sweden)

    Kai-Long Hsiao

    2010-01-01

    Full Text Available A magnetic hydrodynamic (MHD of an incompressible viscoelastic fluid over a stretching sheet with electric and magnetic dissipation and nonuniform heat source/sink has been studied. The buoyant effect and the electric number E1 couple with magnetic parameter M to represent the dominance of the electric and magnetic effects, and adding the specific item of nonuniform heat source/sink is presented in governing equations which are the main contribution of this study. The similarity transformation, the finite-difference method, Newton method, and Gauss elimination method have been used to analyze the present problem. The numerical solutions of the flow velocity distributions, temperature profiles, and the important wall unknown values of f''(0 and θ'(0 have been carried out. The parameter Pr, E1, or Ec can increase the heat transfer effects, but the parameter M or A* may decrease the heat transfer effects.

  14. Parameters and design considerations for tomographic transmission scanners

    International Nuclear Information System (INIS)

    Pentlow, K.S.; Beattie, J.W.; Laughlin, J.S.

    1976-01-01

    The design of transverse axial transmission scanners for reconstruction tomography involves many interrelated parameters and conflicting requirements. We have investigated some of those parameters and their interactions and, where appropriate, attempted to optimize them. It is convenient to group the considerations under four headings: (1) Geometrical factors (basic configurations, rectilinear and fan geometry, moving detectors or static arrays, spatial response variations and field uniformity, and collimation); (2) Radiation energy and sources (Considerations here include transmission versus sensitivity, detector efficiency, collimator penetration, scattered radiation, patient dose, monochromatic versus polychromatic radiation and X-ray tubes versus radionuclide sources); (3) Detection systems (types of detector, detection modes and the rejection of scatter); and (4) Reconstruction mathematics and quantum noise. As a result of such considerations we have proposed a particular design which should have advantages in certain applications

  15. Development of source term evaluation method for Korean Next Generation Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keon Jae; Cheong, Jae Hak; Park, Jin Baek; Kim, Guk Gee [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1997-10-15

    This project had investigate several design features of radioactive waste processing system and method to predict nuclide concentration at primary coolant basic concept of next generation reactor and safety goals at the former phase. In this project several prediction methods of source term are evaluated conglomerately and detailed contents of this project are : model evaluation of nuclide concentration at Reactor Coolant System, evaluation of primary and secondary coolant concentration of reference Nuclear Power Plant(NPP), investigation of prediction parameter of source term evaluation, basic parameter of PWR, operational parameter, respectively, radionuclide removal system and adjustment values of reference NPP, suggestion of source term prediction method of next generation NPP.

  16. Development of the methodology for estimation of dose from a source

    International Nuclear Information System (INIS)

    Golebaone, E.M.

    2012-04-01

    The geometry of a source plays an important role when determining which method to apply in order to accurately estimate dose from a source. If wrong source geometry is used the dose received may be underestimated or overestimated therefore this may lead to wrong decision in dealing with the exposure situation. In this project moisture density gauge was used to represent a point source in order to demonstrate the key parameters to be used when estimating dose from point source. The parameters to be considered are activity of the source, the ambient dose rate, gamma constant for the radionuclide, as well as the transport index on the package of the source. The distance from the source, and the time spent in the radiation field must be known in order to calculate the dose. (author)

  17. Development of a gas-phase field ionization ion source

    International Nuclear Information System (INIS)

    Allan, G.L.; Legge, G.J.F.

    1983-01-01

    A field ionization ion source has been developed to investigate the suitability of using such a source with the Melbourne Proton Microprobe. Operating parameters have been measured, and the source has been found to be brighter than the radiofrequency ion source presently used in the Melbourne 5U Pelletron Accelerator. Improvements to the source geometry to increase the current output are planned

  18. Variability of dynamic source parameters inferred from kinematic models of past earthquakes

    KAUST Repository

    Causse, M.; Dalguer, L. A.; Mai, Paul Martin

    2013-01-01

    We analyse the scaling and distribution of average dynamic source properties (fracture energy, static, dynamic and apparent stress drops) using 31 kinematic inversion models from 21 crustal earthquakes. Shear-stress histories are computed by solving

  19. Vrancea seismic source analysis using a small-aperture array

    International Nuclear Information System (INIS)

    Popescu, E.; Popa, M.; Radulian, M.; Placinta, A.O.

    2005-01-01

    A small-aperture seismic array (BURAR) was installed in 1999 in the northern part of the Romanian territory (Bucovina area). Since then, the array has been in operation under a joint cooperation programme between Romania and USA. The array consists of 10 stations installed in boreholes (nine short period instruments and one broadband instrument) with enough high sensitivity to properly detect earthquakes generated in Vrancea subcrustal domain (at about 250 km epicentral distance) with magnitude M w below 3. Our main purpose is to investigate and calibrate the source parameters of the Vrancea intermediate-depth earthquakes using specific techniques provided by the BURAR array data. Forty earthquakes with magnitudes between 2.9 and 6.0 were selected, including the recent events of September 27, 2004 (45.70 angle N, 26.45 angle E, h = 166 km, M w = 4.7), October 27, 2004 (45.84 angle N, 26.63 angle E, h = 105 km, M w = 6.0) and May 14, 2005 (45.66 angle N, 26.52 angle E, h = 146 km, M w = 5.1), which are the best ever recorded earthquakes on the Romanian territory: Empirical Green's function deconvolution and spectral ratio methods are applied for pairs of collocated events with similar focal mechanism. Stability tests are performed for the retrieved source time function using the array elements. Empirical scaling and calibration relationships are also determined. Our study shows the capability of the BURAR array to determine the source parameters of the Vrancea intermediate-depth earthquakes as a stand alone station and proves that the recordings of this array alone provides reliable and useful tools to efficiently constrain the source parameters and consequently source scaling properties. (authors)

  20. Study of liquid hydrogen and liquid deuterium cold neutron sources

    International Nuclear Information System (INIS)

    Harig, H.D.

    1969-01-01

    In view of the plant of the cold neutron source for a high flux reactor (maximal thermal flux of about 10 15 n/cm 2 s) an experimental study of several cold sources of liquid hydrogen and liquid deuterium has been made in a low power reactor (100 kW, about 10 12 n/cm 2 s). We have investigated: -cold neutron sources of liquid hydrogen shaped as annular layers of different thickness. Normal liquid hydrogen was used as well as hydrogen with a high para-percentage. -Cold neutron sources of liquid deuterium in cylinders of 18 and 38 cm diameter. In this case the sources could be placed into different positions to the reactor core within the heavy water reflector. This report gives a general description of the experimental device and deals more detailed with the design of the cryogenic systems. Then, the measured results are communicated, interpreted and finally compared with those of a theoretical study about the same cold moderators which have been the matter of the experimental investigation. (authors) [fr