WorldWideScience

Sample records for source monitoring abilities

  1. Draw It Again Sam: The Effect of Drawing on Children's Suggestibility and Source Monitoring Ability.

    Science.gov (United States)

    Bruck, Maggie; Melnyk, Laura; Ceci, Stephen J.

    2000-01-01

    Examined the effects of drawing true and false reminders about a previously experienced magic show on 3- to 6-year-olds' suggestibility and source monitoring ability. Found that children who had drawn the reminders had better recall of reminders and better source memory than children who had only answered questions about them. Both groups reported…

  2. Downhole seismic monitoring with Virtual Sources

    Science.gov (United States)

    Bakulin, A.; Calvert, R.

    2005-12-01

    Huge quantities of remaining oil and gas reserves are located in very challenging geological environments covered by salt, basalt or other complex overburdens. Conventional surface seismology struggles to deliver images necessary to economically explore them. Even if those reserves are found by drilling successful production critically depends on our ability to ``see" in real time where fluids are drawn from and how pressure changes throughout the reservoirs. For relatively simple overburdens surface time-lapse (4D) seismic monitoring became industry choice for aerial reservoir surveillance. For complex overburdens, 4D seismic does not have enough resolution and repeatability to answer the questions of reservoir engineers. For instance, often reservoir changes are too small to be detected from surface or these changes occur in such pace that all wells will be placed before we can detect them which greatly reduces the economical impact. Two additional challenges are present in real life that further complicate active monitoring: first, near-surface condition do change between the surveys (water level movement, freezing/thawing, tide variations etc) and second, repeating exact same acquisition geometry at the surface is difficult in practice. Both of these things may lead to false 4D response unrelated to reservoir changes. Virtual Source method (VSM) has been recently proposed as a way to eliminate overburden distortions for imaging and monitoring. VSM acknowledges upfront that our data inversion techniques are unable to unravel the details of the complex overburdens to the extent necessary to remove the distortions caused by them. Therefore VSM advocates placing permanent downhole geophones below that most complex overburden while still exciting signals with a surface sources. For instance, first applications include drilling instrumented wells below complicated near-surface, basalt or salt layer. Of course, in an ideal world we would prefer to have both downhole

  3. Source Monitoring in Alzheimer's Disease

    Science.gov (United States)

    El Haj, Mohamad; Fasotti, Luciano; Allain, Philippe

    2012-01-01

    Source monitoring is the process of making judgments about the origin of memories. There are three categories of source monitoring: reality monitoring (discrimination between self- versus other-generated sources), external monitoring (discrimination between several external sources), and internal monitoring (discrimination between two types of…

  4. Credit Ratings and Bank Monitoring Ability

    NARCIS (Netherlands)

    Nakamura, L.I.; Roszbach, K.

    2010-01-01

    In this paper we use credit rating data from two Swedish banks to elicit evidence on these banks’ loan monitoring ability. We do so by comparing the ability of bank ratings to predict loan defaults relative to that of public ratings from the Swedish credit bureau. We test the banks’ abilility to

  5. [Source monitoring: general presentation and review of literature in schizophrenia].

    Science.gov (United States)

    Ferchiou, A; Schürhoff, F; Bulzacka, E; Mahbouli, M; Leboyer, M; Szöke, A

    2010-09-01

    SOURCE MONITORING FRAMEWORK: Source monitoring refers to the ability to remember the origin of information. Three source monitoring processes can be distinguished: external source monitoring, internal or self-monitoring and reality monitoring (i.e. discrimination between internal and external sources of information). Source monitoring decisions are based on memory characteristics recorded such as perceptions, contextual information or emotional reactions and heuristic or more controlled judgement processes. Several studies suggested that specific structures in the prefrontal and the mediotemporal lobes are the main areas implicated in source monitoring. A typical source monitoring paradigm includes an items generation stage and a second stage of recognition of items (old versus new) and identification of their sources: external (usually the examiner) or internal (the subject). Several indices can be calculated based on the raw data such as the number of false alarms, attribution biases or discrimination indexes. To date, there is no standardized source monitoring task and differences in the type of items used (words, pictures), in the cognitive or emotional effort involved or in the delay between the two test stages, contribute to the heterogeneity of results. Factors such as age (either very young or very old) and emotions influence source monitoring performances. Influence of gender was not properly explored, whereas the role of IQ and selective attention is still debated. Source monitoring deficits are observed mainly in disorders affecting frontotemporal areas, such as frontal trauma, Alzheimer's disease or frontotemporal dementia. Source monitoring errors (e.g. external misattribution of self-generated information) are observed in schizophrenia and seem to correlate with positive symptomatology, in particular auditory hallucinations, thought intrusion and alien control symptoms. These results are of particular interest in clinical research because source

  6. Students’ Self-Monitoring on Mathematics Ability: Cube and Cuboid Problem Solving

    Science.gov (United States)

    Lusiana, N. T.; Lukito, A.; Khabibah, S.

    2018-01-01

    This study aims at describing students’ activity to understand the behaviors processes called self-monitoring in a cube and cuboid problem solving viewed from mathematics ability. The subjects were eight graders of junior high school who studied surface area and volume of cube and cuboid clussified into high, average and low mathematics abilities. Mathematics ability test to select the subjects the study. Data were collected through self-monitoring task and interviews. Data triangulation was used to verify the credibillity findings. Data analysis was done by data condensation, data display and conclusion drawing and verification. Results showed that students’ self-monitoring with high math ability is more fullfilled self-monitoring components. Students with average and low math abilities not fullfilled the component that covers verifying the results during solving the problem. It is expected that teachers must provide different learning treatments to improve students’ self-monitoring for better learning outcomes.

  7. The role of executive function in children's source monitoring with varying retrieval strategies

    Science.gov (United States)

    Earhart, Becky; Roberts, Kim P.

    2014-01-01

    Previous research on the relationship between executive function and source monitoring in young children has been inconclusive, with studies finding conflicting results about whether working memory and inhibitory control are related to source-monitoring ability. In this study, the role of working memory and inhibitory control in recognition memory and source monitoring with two different retrieval strategies were examined. Children (N = 263) aged 4–8 participated in science activities with two sources. They were later given a recognition and source-monitoring test, and completed measures of working memory and inhibitory control. During the source-monitoring test, half of the participants were asked about sources serially (one after the other) whereas the other half of the children were asked about sources in parallel (considering both sources simultaneously). Results demonstrated that working memory was a predictor of source-monitoring accuracy in both conditions, but inhibitory control was only related to source accuracy in the parallel condition. When age was controlled these relationships were no longer significant, suggesting that a more general cognitive development factor is a stronger predictor of source monitoring than executive function alone. Interestingly, the children aged 4–6 years made more accurate source decisions in the parallel condition than in the serial condition. The older children (aged 7–8) were overall more accurate than the younger children, and their accuracy did not differ as a function of interview condition. Suggestions are provided to guide further research in this area that will clarify the diverse results of previous studies examining whether executive function is a cognitive prerequisite for effective source monitoring. PMID:24847302

  8. Individual differences in episodic memory abilities predict successful prospective memory output monitoring.

    Science.gov (United States)

    Hunter Ball, B; Pitães, Margarida; Brewer, Gene A

    2018-02-07

    Output monitoring refers to memory for one's previously completed actions. In the context of prospective memory (PM) (e.g., remembering to take medication), failures of output monitoring can result in repetitions and omissions of planned actions (e.g., over- or under-medication). To be successful in output monitoring paradigms, participants must flexibly control attention to detect PM cues as well as engage controlled retrieval of previous actions whenever a particular cue is encountered. The current study examined individual differences in output monitoring abilities in a group of younger adults differing in attention control (AC) and episodic memory (EM) abilities. The results showed that AC ability uniquely predicted successful cue detection on the first presentation, whereas EM ability uniquely predicted successful output monitoring on the second presentation. The current study highlights the importance of examining external correlates of PM abilities and contributes to the growing body of research on individual differences in PM.

  9. Cognitive abilities, monitoring, and control explain individual differences in heuristics and biases

    Directory of Open Access Journals (Sweden)

    Simon Anthony Jackson

    2016-10-01

    Full Text Available In this paper, we investigate whether individual differences in performance on heuristic and biases tasks can be explained by cognitive abilities, monitoring confidence and control thresholds. Current theories explain individual differences in these tasks by the ability to detect errors and override automatic but biased judgements, and deliberative cognitive abilities that help to construct the correct response. Here we retain cognitive abilities but disentangle error detection, proposing that lower monitoring confidence and higher control thresholds promote error checking. Participants (N = 250 completed tasks assessing their fluid reasoning abilities, stable monitoring confidence levels, and the control threshold they impose on their decisions. They also completed seven typical heuristic and biases tasks such as the cognitive reflection test and resistance to framing. Using structural equation modelling, we found that individuals with higher reasoning abilities, lower monitoring confidence and higher control threshold performed significantly and, at times, substantially better on the heuristic and biases tasks. Individuals with higher control thresholds also showed lower preferences for risky alternatives in a gambling task. Furthermore, residual correlations among the heuristic and biases tasks were reduced to null, indicating that cognitive abilities, monitoring confidence and control thresholds accounted for their shared variance. Implications include the proposal that the capacity to detect errors does not differ between individuals. Rather, individuals might adopt varied strategies that promote error checking to different degrees, regardless of whether they have made a mistake or not. The results support growing evidence that decision making involves cognitive abilities that construct actions and monitoring and control processes that manage their initiation.

  10. [Source-monitoring deficits in schizophrenia: review and pharmacotherapeutic implications].

    Science.gov (United States)

    Juhász, Levente Zsolt; Bartkó, György

    2007-03-01

    The disturbance of source-monitoring is one of the various impairments in cognitive functioning observed in schizophrenic patients. The process of source-monitoring allows individuals to distinguish self generated thoughts and behaviours from those generated by others. The aim of the present study is to review the general psychological definition of source memory and source-monitoring and its neurological basis as well as the models for explanation of source-monitoring deficits. The relationship between source-monitoring-deficits and psychopathological symptoms as well as the effect of antipsychotic treatment on source-monitoring disturbances are introduced. There is evidence suggesting, that a selective source-monitoring deficit is in the occurrence of auditory hallucinations. The disturbance of prospective memory may influence unfavorably the compliance. Administration of antipsychotics in general can improve source-monitoring deficits. The neuropsychiatric perspective provides a more accurate and comprehensive understanding of schizophrenia.

  11. Cognitive Abilities, Monitoring Confidence, and Control Thresholds Explain Individual Differences in Heuristics and Biases.

    Science.gov (United States)

    Jackson, Simon A; Kleitman, Sabina; Howie, Pauline; Stankov, Lazar

    2016-01-01

    In this paper, we investigate whether individual differences in performance on heuristic and biases tasks can be explained by cognitive abilities, monitoring confidence, and control thresholds. Current theories explain individual differences in these tasks by the ability to detect errors and override automatic but biased judgments, and deliberative cognitive abilities that help to construct the correct response. Here we retain cognitive abilities but disentangle error detection, proposing that lower monitoring confidence and higher control thresholds promote error checking. Participants ( N = 250) completed tasks assessing their fluid reasoning abilities, stable monitoring confidence levels, and the control threshold they impose on their decisions. They also completed seven typical heuristic and biases tasks such as the cognitive reflection test and Resistance to Framing. Using structural equation modeling, we found that individuals with higher reasoning abilities, lower monitoring confidence, and higher control threshold performed significantly and, at times, substantially better on the heuristic and biases tasks. Individuals with higher control thresholds also showed lower preferences for risky alternatives in a gambling task. Furthermore, residual correlations among the heuristic and biases tasks were reduced to null, indicating that cognitive abilities, monitoring confidence, and control thresholds accounted for their shared variance. Implications include the proposal that the capacity to detect errors does not differ between individuals. Rather, individuals might adopt varied strategies that promote error checking to different degrees, regardless of whether they have made a mistake or not. The results support growing evidence that decision-making involves cognitive abilities that construct actions and monitoring and control processes that manage their initiation.

  12. 40 CFR 141.701 - Source water monitoring.

    Science.gov (United States)

    2010-07-01

    ... (a)(4) of this section based on the E. coli level that applies to the nearest surface water body. If no surface water body is nearby, the system must comply based on the requirements that apply to... Monitoring Requirements § 141.701 Source water monitoring. (a) Initial round of source water monitoring...

  13. Negative reactions to monitoring: Do they undermine the ability of monitoring to protect adolescents?

    Science.gov (United States)

    Laird, Robert D; Zeringue, Megan M; Lambert, Emily S

    2018-02-01

    This study focused on adolescents' negative reactions to parental monitoring to determine whether parents should avoid excessive monitoring because adolescents find monitoring behaviors to be over-controlling and privacy invasive. Adolescents (n = 242, M age = 15.4 years; 51% female) reported monitoring, negative reactions, warmth, antisocial behavior, depressive symptoms, and disclosure. Adolescents additionally reported antisocial behavior, depressive symptoms, and disclosure one to two years later. In cross-sectional analyses, less monitoring but more negative reactions were linked with less disclosure, suggesting that negative reactions can undermine parents' ability to obtain information. Although monitoring behaviors were not related to depressive symptoms, more negative reactions were linked with more depressive symptoms, suggesting that negative reactions also may increase depressive symptoms as a side effect of monitoring behavior. Negative reactions were not linked to antisocial behavior. There were no longitudinal links between negative reactions and changes in disclosure, antisocial behavior, or depressive symptoms. Copyright © 2017. Published by Elsevier Ltd.

  14. Compliance Groundwater Monitoring of Nonpoint Sources - Emerging Approaches

    Science.gov (United States)

    Harter, T.

    2008-12-01

    Groundwater monitoring networks are typically designed for regulatory compliance of discharges from industrial sites. There, the quality of first encountered (shallow-most) groundwater is of key importance. Network design criteria have been developed for purposes of determining whether an actual or potential, permitted or incidental waste discharge has had or will have a degrading effect on groundwater quality. The fundamental underlying paradigm is that such discharge (if it occurs) will form a distinct contamination plume. Networks that guide (post-contamination) mitigation efforts are designed to capture the shape and dynamics of existing, finite-scale plumes. In general, these networks extend over areas less than one to ten hectare. In recent years, regulatory programs such as the EU Nitrate Directive and the U.S. Clean Water Act have forced regulatory agencies to also control groundwater contamination from non-incidental, recharging, non-point sources, particularly agricultural sources (fertilizer, pesticides, animal waste application, biosolids application). Sources and contamination from these sources can stretch over several tens, hundreds, or even thousands of square kilometers with no distinct plumes. A key question in implementing monitoring programs at the local, regional, and national level is, whether groundwater monitoring can be effectively used as a landowner compliance tool, as is currently done at point-source sites. We compare the efficiency of such traditional site-specific compliance networks in nonpoint source regulation with various designs of regional nonpoint source monitoring networks that could be used for compliance monitoring. We discuss advantages and disadvantages of the site vs. regional monitoring approaches with respect to effectively protecting groundwater resources impacted by nonpoint sources: Site-networks provide a tool to enforce compliance by an individual landowner. But the nonpoint source character of the contamination

  15. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  16. Response of consumer and research grade indoor air quality monitors to residential sources of fine particles.

    Science.gov (United States)

    Singer, B C; Delp, W W

    2018-04-23

    The ability to inexpensively monitor PM 2.5 to identify sources and enable controls would advance residential indoor air quality (IAQ) management. Consumer IAQ monitors incorporating low-cost optical particle sensors and connections with smart home platforms could provide this service if they reliably detect PM 2.5 in homes. In this study, particles from typical residential sources were generated in a 120 m 3 laboratory and time-concentration profiles were measured with 7 consumer monitors (2-3 units each), 2 research monitors (Thermo pDR-1500, MetOne BT-645), a Grimm Mini Wide-Range Aerosol Spectrometer (GRM), and a Tapered Element Oscillating Microbalance with Filter Dynamic Measurement System (FDMS), a Federal Equivalent Method for PM 2.5 . Sources included recreational combustion (candles, cigarettes, incense), cooking activities, an unfiltered ultrasonic humidifier, and dust. FDMS measurements, filter samples, and known densities were used to adjust the GRM to obtain time-resolved mass concentrations. Data from the research monitors and 4 of the consumer monitors-AirBeam, AirVisual, Foobot, Purple Air-were time correlated and within a factor of 2 of the estimated mass concentrations for most sources. All 7 of the consumer and both research monitors substantially under-reported or missed events for which the emitted mass was comprised of particles smaller than 0.3 μm diameter. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. When and where in aging: the role of music on source monitoring.

    Science.gov (United States)

    Palumbo, Rocco; Mammarella, Nicola; Di Domenico, Alberto; Fairfield, Beth

    2018-04-30

    Difficulties in source monitoring (SM) tasks observed in healthy older adults may be linked to associative memory deficits since SM requires individuals to correctly bind and later remember these bound features to discriminate the origin of a memory. Therefore, focusing attention on discriminating factors that may attenuate older adults' difficulties in attributing contextual information to memories is necessary. We investigated the effect of affective information on source monitoring in younger and older adults by manipulating the type of affective information (pictures and music) and assessing the ability to remember spatial and temporal source details for affective pictures encoded while listening to classical music. Older and younger adults viewed a series of affective IAPS pictures presented on the left or right side of the computer screen in two different lists. At test, participants were asked to remember if the picture was seen (right/left), in which list (list1/list2) or whether it was new. Results showed that spatial information was attributed better than temporal information and emotional pictures were attributed better than neutral pictures in both younger and older adults. In addition, although music significantly increased source memory performance in both younger and older participants compared to the white noise condition, the pleasantness of music differentially affected memory for source details. The authors discuss findings in terms of an interaction between music, emotion and cognition in aging.

  18. Events as Power Source: Wireless Sustainable Corrosion Monitoring

    OpenAIRE

    Sun, Guodong; Qiao, Guofu; Zhao, Lin; Chen, Zhibo

    2013-01-01

    This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source), which monitors the corrosion events in reinforced concrete (RC) structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event) releases electric energy; this is ...

  19. Powering embedded electronics for wind turbine monitoring using multi-source energy harvesting techniques

    Science.gov (United States)

    Anton, S. R.; Taylor, S. G.; Raby, E. Y.; Farinholt, K. M.

    2013-03-01

    With a global interest in the development of clean, renewable energy, wind energy has seen steady growth over the past several years. Advances in wind turbine technology bring larger, more complex turbines and wind farms. An important issue in the development of these complex systems is the ability to monitor the state of each turbine in an effort to improve the efficiency and power generation. Wireless sensor nodes can be used to interrogate the current state and health of wind turbine structures; however, a drawback of most current wireless sensor technology is their reliance on batteries for power. Energy harvesting solutions present the ability to create autonomous power sources for small, low-power electronics through the scavenging of ambient energy; however, most conventional energy harvesting systems employ a single mode of energy conversion, and thus are highly susceptible to variations in the ambient energy. In this work, a multi-source energy harvesting system is developed to power embedded electronics for wind turbine applications in which energy can be scavenged simultaneously from several ambient energy sources. Field testing is performed on a full-size, residential scale wind turbine where both vibration and solar energy harvesting systems are utilized to power wireless sensing systems. Two wireless sensors are investigated, including the wireless impedance device (WID) sensor node, developed at Los Alamos National Laboratory (LANL), and an ultra-low power RF system-on-chip board that is the basis for an embedded wireless accelerometer node currently under development at LANL. Results indicate the ability of the multi-source harvester to successfully power both sensors.

  20. Radioactive source monitoring system based on RFID and GPRS

    International Nuclear Information System (INIS)

    He Haiyang; Zhou Hongliang; Zhang Hongjian; Zhang Sheng; Zhou Junru; Weng Guojie

    2011-01-01

    Nuclear radiation produced by radioactive source is harmful to the health of human body, and the lost and theft of radioactive source will cause environmental pollution and social panic. In order to solve the abnormal leaks, accidental loss, theft and other problems of the radioactive source, a radioactive source monitoring system based on RFID, GPS, GPRS and GSM technology is put forward. Radiation dose detector and GPS wireless location module are used to obtain the information of radiation dose and location respectively, RFID reader reads the status of a tag fixed on the bottom of the radioactive source. All information is transmitted to the remote monitoring center via GPRS wireless transmission. There will be an audible and visual alarm when radiation dose is out of limits or the state of radioactive source is abnormal, and the monitoring center will send alarming text messages to the managers through GSM Modem at the same time. Thus, the functions of monitoring and alarming are achieved. The system has already been put into operation and is being kept in functional order. It can provide stable statistics as well as accurate alarm, improving the supervision of radioactive source effectively. (authors)

  1. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Mohd, Shukri [Nondestructive Testing Group, Industrial Technology Division, Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Holford, Karen M.; Pullin, Rhys [Cardiff School of Engineering, Cardiff University, Queen' s Buildings, The Parade, CARDIFF CF24 3AA (United Kingdom)

    2014-02-12

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure.

  2. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    International Nuclear Information System (INIS)

    Shukri Mohd

    2013-01-01

    Full-text: Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed Wavelet Transform analysis and Modal Location (WTML) based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) technique and DeltaTlocation. The results of the study show that the WTML method produces more accurate location results compared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure. (author)

  3. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    International Nuclear Information System (INIS)

    Mohd, Shukri; Holford, Karen M.; Pullin, Rhys

    2014-01-01

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure

  4. New portable monitor enhances the ability to evaluate heat exchanger performance

    International Nuclear Information System (INIS)

    O'Toole, W.; Lacy, J.R.; Karlovich, D.N.

    1992-01-01

    Corrosion and fouling problems in nuclear power plant service water systems have led to industry-wide concern. These problems can affect the ability of these important heat exchangers to remove design heat loads. In addition, a limited amount of permanently installed on-line instrumentation is available to monitor key heat transfer parameters. A new, computerized monitoring system has been developed that acquires and manipulates process data. This enables power plant personnel to evaluate the on-line performance of important cooling system heat exchangers. The equipment provides the capability to continuously monitor, graph, and record cooling and process heat transfer parameters. The computer hardware is in a portable cabinet on wheels, which can be easily rolled from exchanger to exchanger for monitoring. This new monitoring system is being used at Consolidated Edison Company of New York Inc.'s Indian Point 2 Nuclear Station. They are currently expanding their performance testing on service water system heat exchangers and other auxiliary components to include those units that have limited on-line instrumentation. The ability to use clamp on flow and temperature sensing devices is necessary for trending exchanger performance. With on-line testing capabilities it is possible to: evaluate the cleanliness of plant heat transfer surfaces; make judgments about biofouling or antiscalant programs; and determine when equipment needs to be shut down for inspection or cleaning This paper describes this state-of-the-art equipment in detail and its application at the Indian Point 2 Nuclear Station. 9 refs., 8 figs., 1 tab

  5. Sustained attention ability in schizophrenia: Investigation of conflict monitoring mechanisms.

    Science.gov (United States)

    Hoonakker, Marc; Doignon-Camus, Nadège; Marques-Carneiro, José Eduardo; Bonnefond, Anne

    2017-09-01

    The main goal of the current study was to assess, with a time-on-task approach, sustained attention ability in schizophrenia, and to investigate conflict monitoring underlying this ability. Behavioral and event-related potentials data (N2 and P3a amplitudes) were recorded in a long-lasting sustained attention Go/NoGo task (sustained attention to response task, SART), over a period of 30min, in 29 patients with schizophrenia and 29 pair-matched healthy subjects. Our results revealed spared sustained attention ability in patients throughout the task. Impairment of conflict detection (N2) in patients was particularly significant at the end of the task. Furthermore, both schizophrenia and healthy subjects exhibited a decline in conflict detection from the beginning to the middle of the task. Whereas controls' conflict detection recovered in the last part of the task, patients' did not, suggesting a deficit in recovery processes reflecting a lack of additional resources sustained attention Go/NoGo task. Conflict resolution (P3a) was preserved throughout the task in both groups. Conflict monitoring processes are increasingly impaired in schizophrenia during a long-lasting sustained attention Go/NoGo task. This impairment at the end of the task may rely on deficit in recovery processes, rather than a deficit in conflict detection per se in schizophrenia. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  6. Programmes and Systems for Source and Environmental Radiation Monitoring

    International Nuclear Information System (INIS)

    2010-01-01

    The discharge of radionuclides to the atmosphere and aquatic environments is a legitimate practice in the nuclear and other industries, hospitals and research. Where appropriate, monitoring of the discharges and of relevant environmental media is an essential regulatory requirement in order to ensure appropriate radiation protection of the public. Such monitoring provides information on the actual amounts of radioactive material discharged and the radionuclide concentrations in the environment, and is needed to demonstrate compliance with authorized limits, to assess the radiation exposure of members of the public and to provide data to aid in the optimization of radiation protection. Uncontrolled releases of radionuclides to the atmosphere and aquatic environments may occur as a result of a nuclear or radiological accident. Again, monitoring at the source of the release and of the environment is necessary. In this case, monitoring is used both to assess the radiation exposure of members of the public and to determine the actions necessary for public protection, including longer term countermeasures. Source and environmental monitoring associated with the release of radionuclides to the environment is the subject of a number of IAEA Safety Standards, particularly IAEA Safety Standard RS-G-1.8 (Environmental and Source Monitoring for Purposes of Radiation Protection). This publication is intended to complement this Safety Guide and, by so doing, replaces Safety Series No. 41 (Objectives and Design of Environmental Monitoring Programmes for Radioactive Contaminants) and Safety Series No. 46 (Monitoring of Airborne and Liquid Radioactive Releases from Nuclear Facilities to the Environment). Like Safety Standard RS-G-1.8, this Safety Report deals with monitoring at the source and in the environment associated with authorized releases of radionuclides to the environment. It also deals with the general issues of emergency monitoring during and in the aftermath of an

  7. Levels-of-processing effect on internal source monitoring in schizophrenia.

    Science.gov (United States)

    Ragland, J Daniel; McCarthy, Erin; Bilker, Warren B; Brensinger, Colleen M; Valdez, Jeffrey; Kohler, Christian; Gur, Raquel E; Gur, Ruben C

    2006-05-01

    Recognition can be normalized in schizophrenia by providing patients with semantic organizational strategies through a levels-of-processing (LOP) framework. However, patients may rely primarily on familiarity effects, making recognition less sensitive than source monitoring to the strength of the episodic memory trace. The current study investigates whether providing semantic organizational strategies can also normalize patients' internal source-monitoring performance. Sixteen clinically stable medicated patients with schizophrenia and 15 demographically matched healthy controls were asked to identify the source of remembered words following an LOP-encoding paradigm in which they alternated between processing words on a 'shallow' perceptual versus a 'deep' semantic level. A multinomial analysis provided orthogonal measures of item recognition and source discrimination, and bootstrapping generated variance to allow for parametric analyses. LOP and group effects were tested by contrasting recognition and source-monitoring parameters for words that had been encoded during deep versus shallow processing conditions. As in a previous study there were no group differences in LOP effects on recognition performance, with patients and controls benefiting equally from deep versus shallow processing. Although there were no group differences in internal source monitoring, only controls had significantly better performance for words processed during the deep encoding condition. Patient performance did not correlate with clinical symptoms or medication dose. Providing a deep processing semantic encoding strategy significantly improved patients' recognition performance only. The lack of a significant LOP effect on internal source monitoring in patients may reflect subtle problems in the relational binding of semantic information that are independent of strategic memory processes.

  8. Open Source Platform Application to Groundwater Characterization and Monitoring

    Science.gov (United States)

    Ntarlagiannis, D.; Day-Lewis, F. D.; Falzone, S.; Lane, J. W., Jr.; Slater, L. D.; Robinson, J.; Hammett, S.

    2017-12-01

    Groundwater characterization and monitoring commonly rely on the use of multiple point sensors and human labor. Due to the number of sensors, labor, and other resources needed, establishing and maintaining an adequate groundwater monitoring network can be both labor intensive and expensive. To improve and optimize the monitoring network design, open source software and hardware components could potentially provide the platform to control robust and efficient sensors thereby reducing costs and labor. This work presents early attempts to create a groundwater monitoring system incorporating open-source software and hardware that will control the remote operation of multiple sensors along with data management and file transfer functions. The system is built around a Raspberry PI 3, that controls multiple sensors in order to perform on-demand, continuous or `smart decision' measurements while providing flexibility to incorporate additional sensors to meet the demands of different projects. The current objective of our technology is to monitor exchange of ionic tracers between mobile and immobile porosity using a combination of fluid and bulk electrical-conductivity measurements. To meet this objective, our configuration uses four sensors (pH, specific conductance, pressure, temperature) that can monitor the fluid electrical properties of interest and guide the bulk electrical measurement. This system highlights the potential of using open source software and hardware components for earth sciences applications. The versatility of the system makes it ideal for use in a large number of applications, and the low cost allows for high resolution (spatially and temporally) monitoring.

  9. Implementation of the Fissile Mass Flow Monitor Source Verification and Confirmation

    Energy Technology Data Exchange (ETDEWEB)

    Uckan, Taner [ORNL; March-Leuba, Jose A [ORNL; Powell, Danny H [ORNL; Nelson, Dennis [Sandia National Laboratories (SNL); Radev, Radoslav [Lawrence Livermore National Laboratory (LLNL)

    2007-12-01

    This report presents the verification procedure for neutron sources installed in U.S. Department of Energy equipment used to measure fissile material flow. The Fissile Mass Flow Monitor (FMFM) equipment determines the {sup 235}U fissile mass flow of UF{sub 6} gas streams by using {sup 252}Cf neutron sources for fission activation of the UF{sub 6} gas and by measuring the fission products in the flow. The {sup 252}Cf sources in each FMFM are typically replaced every 2 to 3 years due to their relatively short half-life ({approx} 2.65 years). During installation of the new FMFM sources, the source identity and neutronic characteristics provided by the manufacturer are verified with the following equipment: (1) a remote-control video television (RCTV) camera monitoring system is used to confirm the source identity, and (2) a neutron detection system (NDS) is used for source-strength confirmation. Use of the RCTV and NDS permits remote monitoring of the source replacement process and eliminates unnecessary radiation exposure. The RCTV, NDS, and the confirmation process are described in detail in this report.

  10. Implementation of the Fissile Mass Flow Monitor Source Verification and Confirmation

    International Nuclear Information System (INIS)

    Uckan, Taner; March-Leuba, Jose A.; Powell, Danny H.; Nelson, Dennis; Radev, Radoslav

    2007-01-01

    This report presents the verification procedure for neutron sources installed in U.S. Department of Energy equipment used to measure fissile material flow. The Fissile Mass Flow Monitor (FMFM) equipment determines the 235 U fissile mass flow of UF 6 gas streams by using 252 Cf neutron sources for fission activation of the UF 6 gas and by measuring the fission products in the flow. The 252 Cf sources in each FMFM are typically replaced every 2 to 3 years due to their relatively short half-life (∼ 2.65 years). During installation of the new FMFM sources, the source identity and neutronic characteristics provided by the manufacturer are verified with the following equipment: (1) a remote-control video television (RCTV) camera monitoring system is used to confirm the source identity, and (2) a neutron detection system (NDS) is used for source-strength confirmation. Use of the RCTV and NDS permits remote monitoring of the source replacement process and eliminates unnecessary radiation exposure. The RCTV, NDS, and the confirmation process are described in detail in this report.

  11. Events as Power Source: Wireless Sustainable Corrosion Monitoring

    Directory of Open Access Journals (Sweden)

    Guodong Sun

    2013-12-01

    Full Text Available This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source, which monitors the corrosion events in reinforced concrete (RC structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event releases electric energy; this is a novel idea proposed by this study. For accumulating the micro-corrosion energy, we integrate EPS with a COTS (Commercial Off-The-Shelf energy-harvesting chip that recharges a supercapacitor. In particular, this study designs automatic energy management and adaptive transmitted power control polices to efficiently use the constrained accumulated energy. Finally, a set of preliminary experiments based on concrete pore solution are conducted to evaluate the feasibility and the efficacy of EPS.

  12. Events as power source: wireless sustainable corrosion monitoring.

    Science.gov (United States)

    Sun, Guodong; Qiao, Guofu; Zhao, Lin; Chen, Zhibo

    2013-12-17

    This study presents and implements a corrosion-monitoring wireless sensor platform, EPS (Events as Power Source), which monitors the corrosion events in reinforced concrete (RC) structures, while being powered by the micro-energy released from the corrosion process. In EPS, the proposed corrosion-sensing device serves both as the signal source for identifying corrosion and as the power source for driving the sensor mote, because the corrosion process (event) releases electric energy; this is a novel idea proposed by this study. For accumulating the micro-corrosion energy, we integrate EPS with a COTS (Commercial Off-The-Shelf) energy-harvesting chip that recharges a supercapacitor. In particular, this study designs automatic energy management and adaptive transmitted power control polices to efficiently use the constrained accumulated energy. Finally, a set of preliminary experiments based on concrete pore solution are conducted to evaluate the feasibility and the efficacy of EPS.

  13. Brain-behavior relationships in source memory: Effects of age and memory ability.

    Science.gov (United States)

    Meusel, Liesel-Ann; Grady, Cheryl L; Ebert, Patricia E; Anderson, Nicole D

    2017-06-01

    There is considerable evidence for age-related decrements in source memory retrieval, but the literature on the neural correlates of these impairments is mixed. In this study, we used functional magnetic resonance imaging to examine source memory retrieval-related brain activity, and the monotonic relationship between retrieval-related brain activity and source memory accuracy, as a function of both healthy aging (younger vs older) and memory ability within the older adult group (Hi-Old vs Lo-Old). Participants studied lists of word pairs, half visually, half aurally; these were re-presented visually in a scanned test phase and participants indicated if the pair was 'seen' or 'heard' in the study phase. The Lo-Old, but not the Hi-Old, showed source memory performance decrements compared to the Young. During retrieval of source memories, younger and older adults engaged lateral and medial prefrontal cortex (PFC) and medial posterior parietal (and occipital) cortices. The groups differed in how brain activity related to source memory accuracy in dorsal anterior cingulate cortex, precuneus/cuneus, and the inferior parietal cortex; in each of these areas, greater activity was associated with poorer accuracy in the Young, but with higher accuracy in the Hi-Old (anterior cingulate and precuneus/cuneus) and Lo-Old (inferior parietal lobe). Follow-up pairwise group interaction analyses revealed that greater activity in right parahippocampal gyrus was associated with better source memory in the Hi-Old, but not in the Lo-Old. We conclude that older adults recruit additional brain regions to compensate for age-related decline in source memory, but the specific regions involved differ depending on their episodic memory ability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Higher Social Intelligence Can Impair Source Memory

    Science.gov (United States)

    Barber, Sarah J.; Franklin, Nancy; Naka, Makiko; Yoshimura, Hiroki

    2010-01-01

    Source monitoring is made difficult when the similarity between candidate sources increases. The current work examines how individual differences in social intelligence and perspective-taking abilities serve to increase source similarity and thus negatively impact source memory. Strangers first engaged in a cooperative storytelling task. On each…

  15. 40 CFR 141.706 - Reporting source water monitoring results.

    Science.gov (United States)

    2010-07-01

    ... systems serving at least 10,000 people must report the results from the initial source water monitoring... reporting monitoring results that EPA approves. (c) Systems serving fewer than 10,000 people must report.... PWS ID. 2. Facility ID. 3. Sample collection date. 4. Analytical method number. 5. Method type. 6...

  16. [Explicit memory for type font of words in source monitoring and recognition tasks].

    Science.gov (United States)

    Hatanaka, Yoshiko; Fujita, Tetsuya

    2004-02-01

    We investigated whether people can consciously remember type fonts of words by methods of examining explicit memory; source-monitoring and old/new-recognition. We set matched, non-matched, and non-studied conditions between the study and the test words using two kinds of type fonts; Gothic and MARU. After studying words in one way of encoding, semantic or physical, subjects in a source-monitoring task made a three way discrimination between new words, Gothic words, and MARU words (Exp. 1). Subjects in an old/new-recognition task indicated whether test words were previously presented or not (Exp. 2). We compared the source judgments with old/new recognition data. As a result, these data showed conscious recollection for type font of words on the source monitoring task and dissociation between source monitoring and old/new recognition performance.

  17. Monitoring variable X-ray sources in nearby galaxies

    Science.gov (United States)

    Kong, A. K. H.

    2010-12-01

    In the last decade, it has been possible to monitor variable X-ray sources in nearby galaxies. In particular, since the launch of Chandra, M31 has been regularly observed. It is perhaps the only nearby galaxy which is observed by an X-ray telescope regularly throughout operation. With 10 years of observations, the center of M31 has been observed with Chandra for nearly 1 Msec and the X-ray skies of M31 consist of many transients and variables. Furthermore, the X-ray Telescope of Swift has been monitoring several ultraluminous X-ray sources in nearby galaxies regularly. Not only can we detect long-term X-ray variability, we can also find spectral variation as well as possible orbital period. In this talk, I will review some of the important Chandra and Swift monitoring observations of nearby galaxies in the past 10 years. I will also present a "high-definition" movie of M31 and discuss the possibility of detecting luminous transients in M31 with MAXI.

  18. Source term estimation via monitoring data and its implementation to the RODOS system

    International Nuclear Information System (INIS)

    Bohunova, J.; Duranova, T.

    2000-01-01

    A methodology and computer code for interpretation of environmental data, i.e. source term assessment, from on-line environmental monitoring network was developed. The method is based on the conversion of measured dose rates to the source term, i.e. airborne radioactivity release rate, taking into account real meteorological data and location of the monitoring points. The bootstrap estimation methodology and bipivot method to estimate the source term from on-site gamma dose rate monitors is used. The mentioned methods provide an estimate of the mean value of the source term and a confidence interval for it. (author)

  19. All-Sky Monitoring of Variable Sources with Fermi GBM

    Science.gov (United States)

    Wilson-Hodge, Colleen A.; Cherry, Michael L.; Case, Gary L.; Camero-Arranz, Ascension; Chaplin, Vandiver; Connaughton, Valerie; Finger, Mark H.; Jenke, Pater; Rodi, James C.; Baumgartner, Wayne H.; hide

    2011-01-01

    This slide presentation reviews the monitoring of variable sources with the Fermi Gamma Ray Burst Monitor (GBM). It reviews the use of the Earth Occultation technique, the observations of the Crab Nebula with the GBM, and the comparison with other satellite's observations. The instruments on board the four satellites indicate a decline in the Crab from 2008-2010.

  20. Air Monitoring, Measuring, and Emissions Research

    Science.gov (United States)

    Measurement research is advancing the ability to determine the composition of sources of air pollution, conduct exposure assessments, improve monitoring capabilities and support public health research.

  1. The six-spot-step test - a new method for monitoring walking ability in patients with chronic inflammatory polyneuropathy

    DEFF Research Database (Denmark)

    Kreutzfeldt, Melissa; Jensen, Henrik B; Ravnborg, Mads

    2017-01-01

    OBJECTIVE: To evaluate whether the Six-Spot-Step-Test (SSST) is more suitable for monitoring walking ability in patients with chronic inflammatory polyneuropathy than the Timed-25-Foot-Walking test (T25FW). METHOD: In the SSST, participants have to walk as quickly as possible across a field...... of effect size, standardized response means and relative efficiency. Both ambulation tests correlated moderately to PGIC. CONCLUSION: The SSST may be superior to the T25FW in terms of dynamic range, floor effect and responsiveness which makes the SSST a possible alternative for monitoring walking ability...

  2. Open-source digital technologies for low-cost monitoring of historical constructions

    OpenAIRE

    Basto, Camilo; Pelà, Luca; Chacón Flores, Rolando Antonio

    2017-01-01

    This paper shows new possibilities of using novel, open-source, low-cost platforms for the structural health monitoring of heritage structures. The objective of the study is to present an assessment of increasingly available open-source digital modeling and fabrication technologies in order to identify the suitable counterparts of the typical components of a continuous static monitoring system for a historical construction. The results of the research include a simple case-study, which is pre...

  3. Children's Ability to Distinguish between Memories from Multiple Sources: Implications for the Quality and Accuracy of Eyewitness Statements.

    Science.gov (United States)

    Roberts, Kim P.

    2002-01-01

    Outlines five perspectives addressing alternate aspects of the development of children's source monitoring: source-monitoring theory, fuzzy-trace theory, schema theory, person-based perspective, and mental-state reasoning model. Discusses research areas with relation to forensic developmental psychology: agent identity, prospective processing,…

  4. Environmental and Source Monitoring for Purposes of Radiation Protection. Safety Guide (Spanish ed.)

    International Nuclear Information System (INIS)

    2010-01-01

    The purpose of this Safety Guide is to provide international guidance, coherent with contemporary radiation protection principles and IAEA safety requirements, on the strategy of monitoring in relation to: (a) control of radionuclide discharges under practice conditions, and (b) intervention, such as in cases of nuclear or radiological emergencies or past contamination of areas with long lived radionuclides. Three categories of monitoring are discussed: monitoring at the source of the discharge (source monitoring), monitoring in the environment (environmental monitoring) and monitoring of individual exposure in emergencies (individual monitoring). The Safety Guide also provides general guidance on assessment of the doses to critical groups of the population due to the presence of radioactive materials or radiation fields in the environment both from routine operation of nuclear and other related facilities (practice) and from nuclear or radiological emergencies and past contamination of areas with long lived radionuclides (intervention). The dose assessments are based on the results of source monitoring, environmental monitoring, individual monitoring or their combinations. This Safety Guide is primarily intended for use by national regulatory bodies and other agencies involved in national systems of radiation monitoring, as well as by operators of nuclear installations and other facilities where natural or human made radionuclides are treated and monitored. Contents: 1. Introduction; 2. Meeting regulatory requirements for monitoring in practices and interventions; 3. Responsibilities for monitoring; 4. Generic aspects of monitoring programmes; 5. Programmes for monitoring in practices and interventions; 6. Technical conditions for monitoring procedures; 7. Considerations in dose assessment; 8. Interpretation of monitoring results; 9. Quality assurance; 10. Recording of results; 11. Education and training; Glossary.

  5. An inverse source location algorithm for radiation portal monitor applications

    International Nuclear Information System (INIS)

    Miller, Karen A.; Charlton, William S.

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  6. LED-based UV source for monitoring spectroradiometer properties

    Science.gov (United States)

    Sildoja, Meelis-Mait; Nevas, Saulius; Kouremeti, Natalia; Gröbner, Julian; Pape, Sven; Pendsa, Stefan; Sperfeld, Peter; Kemus, Fabian

    2018-06-01

    A compact and stable UV monitoring source based on state-of-the-art commercially available ultraviolet light emitting diodes (UV-LEDs) has been developed. It is designed to trace the radiometric stability—both responsivity and wavelength scale—of array spectroradiometers measuring direct solar irradiance in the wavelength range between 300 nm and 400 nm. The spectral irradiance stability of the UV-LED-based light source observed in the laboratory after seasoning (burning-in) the individual LEDs was better than 0.3% over a 12 h period of continuous operation. The integral irradiance measurements of the source over a period of several months, where the UV-LED source was not operated continuously between the measurements, showed stability within 0.3%. In-field measurements of the source with an array spectroradiometer indicated the stability of the source to be within the standard uncertainty of the spectroradiometer calibration, which was within 1% to 2%.

  7. Patterns of source monitoring bias in incarcerated youths with and without conduct problems.

    Science.gov (United States)

    Morosan, Larisa; Badoud, Deborah; Salaminios, George; Eliez, Stephan; Van der Linden, Martial; Heller, Patrick; Debbané, Martin

    2018-01-01

    Antisocial individuals present behaviours that violate the social norms and the rights of others. In the present study, we examine whether biases in monitoring the self-generated cognitive material might be linked to antisocial manifestations during adolescence. We further examine the association with psychopathic traits and conduct problems (CPs). Sixty-five incarcerated adolescents (IAs; M age = 15.85, SD = 1.30) and 88 community adolescents (CAs; M age = 15.78, SD = 1.60) participated in our study. In the IA group, 28 adolescents presented CPs (M age = 16.06, SD = 1.41) and 19 did not meet the diagnostic criteria for CPs (M age = 15.97, SD = 1.20). Source monitoring was assessed through a speech-monitoring task, using items requiring different levels of cognitive effort; recognition and source-monitoring bias scores (internalising and externalising biases) were calculated. Between-group comparisons indicate greater overall biases and different patterns of biases in the source monitoring. IA participants manifest a greater externalising bias, whereas CA participants present a greater internalising bias. In addition, IA with CPs present different patterns of item recognition. These results indicate that the two groups of adolescents present different types of source-monitoring bias for self-generated speech. In addition, the IAs with CPs present impairments in item recognition. Future studies may examine the developmental implications of self-monitoring biases in the perseverance of antisocial behaviours from adolescence to adulthood.

  8. Anomaly metrics to differentiate threat sources from benign sources in primary vehicle screening.

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Israel Dov; Mengesha, Wondwosen

    2011-09-01

    Discrimination of benign sources from threat sources at Port of Entries (POE) is of a great importance in efficient screening of cargo and vehicles using Radiation Portal Monitors (RPM). Currently RPM's ability to distinguish these radiological sources is seriously hampered by the energy resolution of the deployed RPMs. As naturally occurring radioactive materials (NORM) are ubiquitous in commerce, false alarms are problematic as they require additional resources in secondary inspection in addition to impacts on commerce. To increase the sensitivity of such detection systems without increasing false alarm rates, alarm metrics need to incorporate the ability to distinguish benign and threat sources. Principal component analysis (PCA) and clustering technique were implemented in the present study. Such techniques were investigated for their potential to lower false alarm rates and/or increase sensitivity to weaker threat sources without loss of specificity. Results of the investigation demonstrated improved sensitivity and specificity in discriminating benign sources from threat sources.

  9. Look who's talking! Facial appearance can bias source monitoring

    OpenAIRE

    Nash, RA; Bryer, OM; Schlaghecken, F

    2010-01-01

    When we see a stranger's face we quickly form impressions of his or her personality, and expectations of how the stranger might behave. Might these intuitive character judgements bias source monitoring? Participants read headlines oreportedo by a trustworthy- and an untrustworthy-looking reporter. Subsequently, participants recalled which reporter provided each headline. Source memory for likely-sounding headlines was most accurate when a trustworthy-looking reporter had provided the headline...

  10. Post-encoding emotional arousal enhances consolidation of item memory, but not reality-monitoring source memory.

    Science.gov (United States)

    Wang, Bo; Sun, Bukuan

    2017-03-01

    The current study examined whether the effect of post-encoding emotional arousal on item memory extends to reality-monitoring source memory and, if so, whether the effect depends on emotionality of learning stimuli and testing format. In Experiment 1, participants encoded neutral words and imagined or viewed their corresponding object pictures. Then they watched a neutral, positive, or negative video. The 24-hour delayed test showed that emotional arousal had little effect on both item memory and reality-monitoring source memory. Experiment 2 was similar except that participants encoded neutral, positive, and negative words and imagined or viewed their corresponding object pictures. The results showed that positive and negative emotional arousal induced after encoding enhanced consolidation of item memory, but not reality-monitoring source memory, regardless of emotionality of learning stimuli. Experiment 3, identical to Experiment 2 except that participants were tested only on source memory for all the encoded items, still showed that post-encoding emotional arousal had little effect on consolidation of reality-monitoring source memory. Taken together, regardless of emotionality of learning stimuli and regardless of testing format of source memory (conjunction test vs. independent test), the facilitatory effect of post-encoding emotional arousal on item memory does not generalize to reality-monitoring source memory.

  11. Use of Portal Monitors for Detection of Technogenic Radioactive Sources in Scrap Metal

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    The article considers the features of organization of scrap-metal primary radiation control on the specialized enterprises engaging in its deep processing and storage at using by primary technical equipment - radiation portal monitors. The issue of this direction relevance, validity of radiation control implementation with the use of radiation portal monitors, physical and organizational bases of radiation control are considered in detail. The emphasis is put on the considerable increase in the number of technogenic radioactive sources detected in scrap-metal that results in the entering into exploitation of radioactive metallic structures as different building wares. One of reasons of such increase of the number of technogenic radioactive sources getting for processing with scrap-metal is the absence of any recommendations on the radiation portal monitors exploitation. The practical division of the article offers to recommendation on tuning of the modes of work of radiation portal monitors depending on influence the weather factor thus allowing to considerably increase the percent of technogenic radioactive sources detection.

  12. Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources

    Science.gov (United States)

    Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai

    2018-01-01

    Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.

  13. Tools for Trade Analysis and Open Source Information Monitoring for Non-proliferation

    International Nuclear Information System (INIS)

    Cojazzi, G.G.M.; Versino, C.; Wolfart, E.; Renda, G.; Janssens, W.A.M.; )

    2015-01-01

    The new state level approach being proposed by IAEA envisions an objective based and information driven safeguards approach utilizing all relevant information to improve the effectiveness and efficiency of safeguards. To this goal the IAEA makes also use of open source information, here broadly defined as any information that is neither classified nor proprietary. It includes, but is not limited to: media sources, government and non-governmental reports and analyzes, commercial data, and scientific/technical literature, including trade data. Within the EC support programme to IAEA, JRC has surveyed and catalogued open sources on import-export customs trade data and developed tools for supporting the use of the related databases in safeguards. The JRC software The Big Table, (TBT), supports i.a.: a) the search through a collection of reference documents relevant to trade analysis (legal/regulatory documents, technical handbooks); b) the selection of items of interests to specific verifications and c) the mapping of these items to customs commodities searchable in trade databases. In the field of open source monitoring, JRC is developing and operating a ''Nuclear Security Media Monitor'' (NSMM), which is a web-based multilingual news aggregation system that automatically collects news articles from pre-defined web sites. NSMM is a domain specific version of the general JRC-Europe Media Monitor (EMM). NSMM has been established within the EC support programme with the aim, i.e., to streamline IAEA's process of open source information monitoring. In the first part, the paper will recall the trade data sources relevant for non-proliferation and will then illustrate the main features of TBT, recently coupled with the IAEA Physical Model, and new visualization techniques applied to trade data. In the second part it will present the main aspects of the NSMM also by illustrating some of uses done at JRC. (author)

  14. Deformation Monitoring of the Spallation Neutron Source (SNS) Tunnels

    CERN Document Server

    Error, J J; Fazekas, J J; Helus, S A; Maines, J R

    2005-01-01

    The SNS Project is a 1.4 MW accelerator-based neutron source located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. For shielding purposes, a 17 foot berm of native soil has been constructed on top of the accelerator tunnel system. This backfill has caused ongoing settlement of the tunnels. The settlement has been monitored by the SNS Survey and Alignment Group at regular intervals, in order to discover the patterns of deformation, and to determine when the tunnels will be stable enough for precise alignment of beam line components. The latest monitoring results indicate that the settlement rate has significantly decreased. This paper discusses the techniques and instrumentation of the monitoring surveys, and provides an analysis of the results.

  15. The NASA Goddard Group's Source Monitoring Database and Program

    Science.gov (United States)

    Gipson, John; Le Bail, Karine; Ma, Chopo

    2014-12-01

    Beginning in 2003, the Goddard VLBI group developed a program to purposefully monitor when sources were observed and to increase the observations of ``under-observed'' sources. The heart of the program consists of a MySQL database that keeps track of, on a session-by-session basis: the number of observations that are scheduled for a source, the number of observations that are successfully correlated, and the number of observations that are used in a session. In addition, there is a table that contains the target number of successful sessions over the last twelve months. Initially this table just contained two categories. Sources in the geodetic catalog had a target of 12 sessions/year; the remaining ICRF-1 defining sources had a target of two sessions/year. All other sources did not have a specific target. As the program evolved, different kinds of sources with different observing targets were added. During the scheduling process, the scheduler has the option of automatically selecting N sources which have not met their target. We discuss the history and present some results of this successful program.

  16. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Li Yuan; Zhu Ren Yuan; Liu Dun Can

    2000-01-01

    Light monitoring will serve as an inter calibration for CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's sub percent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO//4 crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. 29 Refs.

  17. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    Energy Technology Data Exchange (ETDEWEB)

    Bloomer, Chris, E-mail: chris.bloomer@diamond.ac.uk; Rehm, Guenther; Dolbnya, Igor P. [Diamond Light Source Ltd, Oxfordshire (United Kingdom)

    2016-07-27

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  18. An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

    International Nuclear Information System (INIS)

    Bloomer, Chris; Rehm, Guenther; Dolbnya, Igor P.

    2016-01-01

    Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

  19. Synergies of multiple remote sensing data sources for REDD+ monitoring

    NARCIS (Netherlands)

    Sy, de V.; Herold, M.; Achard, F.; Asner, G.P.; Held, A.; Kellndorfer, J.; Verbesselt, J.

    2012-01-01

    Remote sensing technologies can provide objective, practical and cost-effective solutions for developing and maintaining REDD+ monitoring systems. This paper reviews the potential and status of available remote sensing data sources with a focus on different forest information products and synergies

  20. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Liang Ying; Zhu, R Y; Liu, D T

    2001-01-01

    Light monitoring will serve as an intercalibration for Compact Muon Solenoid (CMS) lead tungstate crystals in situ at the Large Hadronic Collider, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO/sub 4/ crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (12 refs).

  1. The influence of signal parameters on the sound source localization ability of a harbor porpoise (Phocoena phocoena)

    NARCIS (Netherlands)

    Kastelein, R.A.; Haan, D.de; Verboom, W.C.

    2007-01-01

    It is unclear how well harbor porpoises can locate sound sources, and thus can locate acoustic alarms on gillnets. Therefore the ability of a porpoise to determine the location of a sound source was determined. The animal was trained to indicate the active one of 16 transducers in a 16-m -diam

  2. Work ability assessment in a worker population: comparison and determinants of Work Ability Index and Work Ability score

    OpenAIRE

    El Fassi, Mehdi; Bocquet, Valery; Majery, Nicole; Lair, Marie Lise; Couffignal, Sophie; Mairiaux, Philippe

    2013-01-01

    Background Public authorities in European countries are paying increasing attention to the promotion of work ability throughout working life and the best method to monitor work ability in populations of workers is becoming a significant question. The present study aims to compare the assessment of work ability based on the use of the Work Ability Index (WAI), a 7-item questionnaire, with another one based on the use of WAI?s first item, which consists in the worker?s self-assessment of his/he...

  3. Determination of void fraction from source range monitor and mass flow rate data

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-09-01

    This is a report on the calculation of the TMI-2 primary coolant system local void fraction from source range neutron flux monitor data and from hot leg mass flowrate meter data during the first 100 minutes of the accident. The methods of calculation of void fraction from the two data sources is explained and the results are compared. It is indicated that the void fraction determined using the mass flowrate data contained an error of unknown magnitude due to the assumption of constant homogeneous volumetric flowrate used in the calculation and required further work. Void fraction determined from the source range monitor data is felt to be usable although an uncertainty analysis has not been performed

  4. Spotting Radioactive Sources Buried Underground Using an Airborne Radiation Monitoring System

    International Nuclear Information System (INIS)

    Sheinfeld, M.; Wengrowicz, U.; Beck, A.; Marcus, E.; Tirosh, D.

    2002-01-01

    This article provides theoretical background concerning the capability of the Airborne Radiation Monitoring System [1]to detect fission products buried at 1-meter depth under the ground surface,at a flight altitude of 100 meters above ground.The 137 Cs source was used as a typical fission product. The System monitors radioactive contamination in the air or on the ground using two 2 inch NaI(Tl) scintillation detectors and computerized accessories for analysis purposes

  5. 40 CFR 141.402 - Ground water source microbial monitoring and analytical methods.

    Science.gov (United States)

    2010-07-01

    ... approves the use of E. coli as a fecal indicator for source water monitoring under this paragraph (a). If the repeat sample collected from the ground water source is E.coli positive, the system must comply... listed in the in paragraph (c)(2) of this section for the presence of E. coli, enterococci, or coliphage...

  6. Available data sources for monitoring non-communicable diseases and their risk factors in South Africa

    Directory of Open Access Journals (Sweden)

    M Wandai

    2017-04-01

    Full Text Available Background. Health information systems for monitoring chronic non-communicable diseases (NCDs in South Africa (SA are relatively less advanced than those for infectious diseases (particularly tuberculosis and HIV and for maternal and child health. NCDs are now the largest cause of premature mortality owing to exposure to risk factors arising from obesity that include physical inactivity and accessible, cheap but unhealthy diets. The National Strategic Plan for the Prevention and Control of Non-Communicable Diseases 2013 - 17 developed by the SA National Department of Health outlines targets and monitoring priorities. Objectives. To assess data sources relevant for monitoring NCDs and their risk factors by identifying the strengths and weaknesses, including usability and availability, of surveys and routine systems focusing at national and certain sub-national levels. Methods. Publicly available survey and routine data sources were assessed for variables collected, their characteristics, frequency of data collection, geographical coverage and data availability. Results. Survey data sources were found to be quite different in the way data variables are collected, their geographical coverage and also availability, while the main weakness of routine data sources was poor quality of data. Conclusions. To provide a sound basis for monitoring progress of NCDs and related risk factors, we recommend harmonising and strengthening available SA data sources in terms of data quality, definitions, categories used, timeliness, disease coverage and biomarker measurement.

  7. Open Source Based Sensor Platform for Mobile Environmental Monitoring and Data Acquisition

    Science.gov (United States)

    Schima, Robert; Goblirsch, Tobias; Misterek, René; Salbach, Christoph; Schlink, Uwe; Francyk, Bogdan; Dietrich, Peter; Bumberger, Jan

    2016-04-01

    The impact of global change, urbanization and complex interactions between humans and the environment show different effects on different scales. However, the desire to obtain a better understanding of ecosystems and process dynamics in nature accentuates the need for observing these processes in higher temporal and spatial resolutions. Especially with regard to the process dynamics and heterogeneity of urban areas, a comprehensive monitoring of these effects remains to be a challenging issue. Open source based electronics and cost-effective sensors are offering a promising approach to explore new possibilities of mobile data acquisition and innovative strategies and thereby support a comprehensive ad-hoc monitoring and the capturing of environmental processes close to real time. Accordingly, our project aims the development of new strategies for mobile data acquisition and real-time processing of user-specific environmental data, based on a holistic and integrated process. To this end, the concept of our monitoring system covers the data collection, data processing and data integration as well as the data provision within one infrastructure. This ensures a consistent data stream and a rapid data processing. However, the overarching goal is the provision of an integrated service instead of lengthy and arduous data acquisition by hand. Therefore, the system also serves as a data acquisition assistant and gives guidance during the measurements. In technical terms, our monitoring system consists of mobile sensor devices, which can be controlled and managed by a smart phone app (Android). At the moment, the system is able to acquire temperature and humidity in space (GPS) and time (real-time clock) as a built in function. In addition, larger system functionality can be accomplished by adding further sensors for the detection of e.g. fine dust, methane or dissolved organic compounds. From the IT point of view, the system includes a smart phone app and a web service for

  8. Beam position monitor data acquisition for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Lenkszus, F.R.; Kahana, E.; Votaw, A.J.; Decker, G.A.; Chung, Y.; Ciarlette, D.J.; Laird, R.J.

    1993-01-01

    This paper describes the Beam Position Monitor (BPM) data acquisition scheme for the Advanced Photon Source (APS) storage ring. The storage ring contains 360 beam position monitors distributed around its 1104-meter circumference. The beam position monitor data acquisition system is capable of making turn-by-turn measurements of all BPMs simultaneously. It is VXI-based with each VXI crate containing the electronics for 9 BPMS. The VXI Local Bus is used to provide sustained data transfer rates of up to 13 mega-transfers per second to a scanner module. The system provides single-bunch tracking, bunch-to-bunch measurements, fast digital-averaged positions, beam position history buffering, and synchronized multi-turn measurements. Data is accessible to the control system VME crates via an MXI bus. Dedicated high-speed ports are provided to supply position data to beam orbit feedback systems

  9. A radio monitoring survey of ultra-luminous X-ray sources

    Science.gov (United States)

    Körding, E.; Colbert, E.; Falcke, H.

    2005-06-01

    We present the results of a radio monitoring campaign to search for radio emission from nearby ultra-luminous X-ray sources (ULXs). These sources are bright off-nuclear X-ray point sources with luminosities exceeding LX > 1039 erg s-1. A well-defined sample of the 9 nearest ULXs has been monitored eight times over 5 months with the Very Large Array in A and B configuration. Our limiting sensitivity is ≈0.15 mJy (4σ) for radio flares and ≈60 μJy for continuous emission. In M 82 two ULXs seem to have coincident compact radio sources, which are probably supernova remnants. No continuous or flaring radio emission has been detected from any other ULX. Thus, ULXs do not generally emit steady-state radio emission above radio powers of 1.5 × 1017 W/Hz. The non-detections of the continuous emission are consistent with beamed or unbeamed radio emission from accreting black holes of ≤ 103 M⊙ based on the radio/X-ray correlation. Other published radio detections (M 82, NGC 5408) are also discussed in this context. Both detections are significantly above our detection limit. If ULXs have flaring radio emission above 4 × 1017 W/Hz we can give an upper limit on the duty cycle of the flares of 6%. This upper limit is in agreement with the observed number of flares in Galactic radio transients. Additionally we present a yet unreported radio double structure in the nearby low-luminosity AGN NGC 4736.

  10. TMI-2 source and intermediate range neutron flux monitors data report

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-03-01

    This is a report on the preparation of data from the TMI-2 excore source and intermediate range neutron flux monitors for inclusion into the TMI Data Base. The sources of the as-recorded data are discussed as well as the process of transforming these data into digital form. The corrections to the as-recorded data are given and the data quality classification and uncertainty are established. The identifiers attached to each data set in the TMI Data Base are given

  11. Multi-Source Autonomous Response for Targeting and Monitoring of Volcanic Activity

    Science.gov (United States)

    Davies, Ashley G.; Doubleday, Joshua R.; Tran, Daniel Q.

    2014-01-01

    The study of volcanoes is important for both purely scientific and human survival reasons. From a scientific standpoint, volcanic gas and ash emissions contribute significantly to the terrestrial atmosphere. Ash depositions and lava flows can also greatly affect local environments. From a human survival standpoint, many people live within the reach of active volcanoes, and therefore can be endangered by both atmospheric (ash, debris) toxicity and lava flow. There are many potential information sources that can be used to determine how to best monitor volcanic activity worldwide. These are of varying temporal frequency, spatial regard, method of access, and reliability. The problem is how to incorporate all of these inputs in a general framework to assign/task/reconfigure assets to monitor events in a timely fashion. In situ sensing can provide a valuable range of complementary information such as seismographic, discharge, acoustic, and other data. However, many volcanoes are not instrumented with in situ sensors, and those that have sensor networks are restricted to a relatively small numbers of point sensors. Consequently, ideal volcanic study synergistically combines space and in situ measurements. This work demonstrates an effort to integrate spaceborne sensing from MODIS (Terra and Aqua), ALI (EO-1), Worldview-2, and in situ sensing in an automated scheme to improve global volcano monitoring. Specifically, it is a "sensor web" concept in which a number of volcano monitoring systems are linked together to monitor volcanic activity more accurately, and this activity measurement automatically tasks space assets to acquire further satellite imagery of ongoing volcanic activity. A general framework was developed for evidence combination that accounts for multiple information sources in a scientist-directed fashion to weigh inputs and allocate observations based on the confidence of an events occurrence, rarity of the event at that location, and other scientists

  12. Sources of uncertainty in individual monitoring for photographic,TL and OSL dosimetry techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Max S.; Silva, Everton R.; Mauricio, Claudia L.P., E-mail: max.das.ferreira@gmail.com, E-mail: everton@ird.gov.br, E-mail: claudia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The identification of the uncertainty sources and their quantification is essential to the quality of any dosimetric results. If uncertainties are not stated for all dose measurements informed in the monthly dose report to the monitored radiation facilities, they need to be known. This study aims to analyze the influence of different sources of uncertainties associated with photographic, TL and OSL dosimetric techniques, considering the evaluation of occupational doses of whole-body exposure for photons. To identify the sources of uncertainty it was conducted a bibliographic review in specific documents that deal with operational aspects of each technique and the uncertainties associated to each of them. Withal, technical visits to individual monitoring services were conducted to assist in this identification. The sources of uncertainty were categorized and their contributions were expressed in a qualitative way. The process of calibration and traceability are the most important sources of uncertainties, regardless the technique used. For photographic dosimetry, the remaining important uncertainty sources are due to: energy and angular dependence; linearity of response; variations in the films processing. For TL and OSL, the key process for a good performance is respectively the reproducibility of the thermal and optical cycles. For the three techniques, all procedures of the measurement process must be standardized, controlled and reproducible. Further studies can be performed to quantify the contribution of the sources of uncertainty. (author)

  13. The Influence of Task Demands, Verbal Ability and Executive Functions on Item and Source Memory in Autism Spectrum Disorder

    Science.gov (United States)

    Semino, Sara; Ring, Melanie; Bowler, Dermot M.; Gaigg, Sebastian B.

    2018-01-01

    Autism Spectrum Disorder (ASD) is generally associated with difficulties in contextual source memory but not single item memory. There are surprising inconsistencies in the literature, however, that the current study seeks to address by examining item and source memory in age and ability matched groups of 22 ASD and 21 comparison adults. Results…

  14. Age-Appropriate Cues Facilitate Source-Monitoring and Reduce Suggestibility in 3- To 7-Year-Olds

    Science.gov (United States)

    Bright-Paul, A.; Jarrold, C.; Wright, D.B.

    2005-01-01

    Providing cues to facilitate the recovery of source information can reduce postevent misinformation effects in adults, implying that errors in source-monitoring contribute to suggestibility (e.g., [Lindsay, D. S., & Johnson, M. K. (1989). The eyewitness suggestibility effect and memory for source. Memory & Cognition, 17, 349-358]). The present…

  15. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Luo, Haoze; Iannuzzo, Francesco

    2017-01-01

    the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal......-Oxide-Semiconductor-Field-Effect Transistors (MOSFETs), it is shown that there are opposing trends in the evolution of the on-state resistances of both the bond-wires and the MOSFET die. In summary, after 50,000 temperature cycles, the resistance of the bond-wires increased by up to 2 mΩ, while the on-state resistance of the MOSFET dies...... decreased by approximately 1 mΩ. The conventional failure precursor (monitoring a single forward voltage) cannot distinguish between semiconductor die or bond-wire degradation. Therefore, the ability to monitor both these parameters due to the presence of an auxiliary-source terminal can provide more...

  16. Volcano Monitoring using Multiple Remote Data Sources

    Science.gov (United States)

    Reath, K. A.; Pritchard, M. E.

    2016-12-01

    Satellite-based remote sensing instruments can be used to determine quantitative values related to precursory activity that can act as a warning sign of an upcoming eruption. These warning signs are measured through examining anomalous activity in: (1) thermal flux, (2) gas/aerosol emission rates, (3) ground deformation, and (4) ground-based seismic readings. Patterns in each of these data sources are then analyzed to create classifications of different phases of precursory activity. These different phases of activity act as guidelines to monitor the progression of precursory activity leading to an eruption. Current monitoring methods rely on using high temporal resolution satellite imagery from instruments like the Advanced Very High Resolution Radiometer (AVHRR) and the Moderate Resolution Imaging Spectrometer (MODIS) sensors, for variations in thermal and aerosol emissions, and the Ozone Monitoring Instruments (OMI) and Ozone Mapping Profiler Suite (OMPS) instruments, for variations in gas emissions, to provide a valuable resource for near real-time monitoring of volcanic activity. However, the low spatial resolution of these data only enable events that produce a high thermal output or a large amount of gas/aerosol emissions to be detected. High spatial resolution instruments, like the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) sensor, have a small enough pixel size (90m2) that the subtle variations in both thermal flux and gas/aerosol emission rates in the pre-eruptive period can be detected. Including these data with the already established high temporal resolution data helps to identify and classify precursory activity patterns months before an eruption (Reath et al, 2016). By correlating these data with ground surface deformation data, determined from the Interferometric Synthetic Aperture Radar (InSAR) sensor, and seismic data, collected by the Incorporated Research Institution for Seismology (IRIS) data archive, subtle

  17. Real-time particle monitor calibration factors and PM2.5 emission factors for multiple indoor sources.

    Science.gov (United States)

    Dacunto, Philip J; Cheng, Kai-Chung; Acevedo-Bolton, Viviana; Jiang, Ruo-Ting; Klepeis, Neil E; Repace, James L; Ott, Wayne R; Hildemann, Lynn M

    2013-08-01

    Indoor sources can greatly contribute to personal exposure to particulate matter less than 2.5 μm in diameter (PM2.5). To accurately assess PM2.5 mass emission factors and concentrations, real-time particle monitors must be calibrated for individual sources. Sixty-six experiments were conducted with a common, real-time laser photometer (TSI SidePak™ Model AM510 Personal Aerosol Monitor) and a filter-based PM2.5 gravimetric sampler to quantify the monitor calibration factors (CFs), and to estimate emission factors for common indoor sources including cigarettes, incense, cooking, candles, and fireplaces. Calibration factors for these indoor sources were all significantly less than the factory-set CF of 1.0, ranging from 0.32 (cigarette smoke) to 0.70 (hamburger). Stick incense had a CF of 0.35, while fireplace emissions ranged from 0.44-0.47. Cooking source CFs ranged from 0.41 (fried bacon) to 0.65-0.70 (fried pork chops, salmon, and hamburger). The CFs of combined sources (e.g., cooking and cigarette emissions mixed) were linear combinations of the CFs of the component sources. The highest PM2.5 emission factors per time period were from burned foods and fireplaces (15-16 mg min(-1)), and the lowest from cooking foods such as pizza and ground beef (0.1-0.2 mg min(-1)).

  18. Development of AN Open-Source Automatic Deformation Monitoring System for Geodetical and Geotechnical Measurements

    Science.gov (United States)

    Engel, P.; Schweimler, B.

    2016-04-01

    The deformation monitoring of structures and buildings is an important task field of modern engineering surveying, ensuring the standing and reliability of supervised objects over a long period. Several commercial hardware and software solutions for the realization of such monitoring measurements are available on the market. In addition to them, a research team at the Neubrandenburg University of Applied Sciences (NUAS) is actively developing a software package for monitoring purposes in geodesy and geotechnics, which is distributed under an open source licence and free of charge. The task of managing an open source project is well-known in computer science, but it is fairly new in a geodetic context. This paper contributes to that issue by detailing applications, frameworks, and interfaces for the design and implementation of open hardware and software solutions for sensor control, sensor networks, and data management in automatic deformation monitoring. It will be discussed how the development effort of networked applications can be reduced by using free programming tools, cloud computing technologies, and rapid prototyping methods.

  19. Gender differences in multitasking reflect spatial ability.

    Science.gov (United States)

    Mäntylä, Timo

    2013-04-01

    Demands involving the scheduling and interleaving of multiple activities have become increasingly prevalent, especially for women in both their paid and unpaid work hours. Despite the ubiquity of everyday requirements to multitask, individual and gender-related differences in multitasking have gained minimal attention in past research. In two experiments, participants completed a multitasking session with four gender-fair monitoring tasks and separate tasks measuring executive functioning (working memory updating) and spatial ability (mental rotation). In both experiments, males outperformed females in monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of monitoring accuracy, but only spatial ability mediated gender differences in multitasking. Menstrual changes accentuated these effects, such that gender differences in multitasking (and spatial ability) were eliminated between males and females who were in the menstrual phase of the menstrual cycle but not between males and females who were in the luteal phase. These findings suggest that multitasking involves spatiotemporal task coordination and that gender differences in multiple-task performance reflect differences in spatial ability.

  20. Remote monitoring of radioactive sources based on i.MX27 platform

    International Nuclear Information System (INIS)

    Li Defeng; Wang Renbo; Lin Gangyong; Ding Yufei

    2012-01-01

    It based on the ASIC solutions, has chosen Freescale's i.MX27 development system as a platform for designing video capture and transmission system. The article uses the latest H.264 video compression standard and complete the entire system of hardware and software design, which is successfully applied to remote monitoring of radioactive sources. (authors)

  1. Advanced Light Source beam position monitor

    International Nuclear Information System (INIS)

    Hinkson, J.

    1991-01-01

    The Advanced Light Source (ALS) is a synchrotron radiation facility nearing completion at LBL. As a third-generation machine, the ALS is designed to produce intense light from bend magnets, wigglers, and undulators (insertion devices). The facility will include a 50 MeV electron linear accelerator, a 1.5 GeV booster synchrotron, beam transport lines, a 1--2 GeV storage ring, insertion devices, and photon beam lines. Currently, the beam injection systems are being commissioned, and the storage ring is being installed. Electron beam position monitors (BPM) are installed throughout the accelerator and constitute the major part of accelerator beam diagnostics. The design of the BPM instruments is complete, and 50 units have been constructed for use in the injector systems. We are currently fabricating 100 additional instruments for the storage ring. In this paper I discuss engineering fabrication, testing and performance of the beam pickup electrodes and the BPM electronics

  2. Area radiation monitor at the intense pulsed-neutron source

    International Nuclear Information System (INIS)

    Eichholz, J.J.; Lynch, F.J.; Mundis, R.L.; Howe, M.L.; Dolecek, E.H.

    1981-01-01

    A tissue-equivalent ionization chamber with associated circuitry has been developed for area radiation monitoring in the Intense Pulsed-Neutron Source (IPNS) facility at Argonne National Laboratory. The conventional chamber configuration was modified in order to increase the electric field and effective volume thereby achieving higher sensitivity and linearity. The instrument provides local and remote radiation level indications and a high level alarm. Twenty-four of these instruments were fabricated for use at various locations in the experimental area of the IPNS-1 facility

  3. Soil Monitor: an open source web application for real-time soil sealing monitoring and assessment

    Science.gov (United States)

    Langella, Giuliano; Basile, Angelo; Giannecchini, Simone; Iamarino, Michela; Munafò, Michele; Terribile, Fabio

    2016-04-01

    Soil sealing is one of the most important causes of land degradation and desertification. In Europe, soil covered by impermeable materials has increased by about 80% from the Second World War till nowadays, while population has only grown by one third. There is an increasing concern at the high political levels about the need to attenuate imperviousness itself and its effects on soil functions. European Commission promulgated a roadmap (COM(2011) 571) by which the net land take would be zero by 2050. Furthermore, European Commission also published a report in 2011 providing best practices and guidelines for limiting soil sealing and imperviousness. In this scenario, we developed an open source and an open source based Soil Sealing Geospatial Cyber Infrastructure (SS-GCI) named as "Soil Monitor". This tool merges a webGIS with parallel geospatial computation in a fast and dynamic fashion in order to provide real-time assessments of soil sealing at high spatial resolution (20 meters and below) over the whole Italy. Common open source webGIS packages are used to implement both the data management and visualization infrastructures, such as GeoServer and MapStore. The high-speed geospatial computation is ensured by a GPU parallelism using the CUDA (Computing Unified Device Architecture) framework by NVIDIA®. This kind of parallelism required the writing - from scratch - all codes needed to fulfil the geospatial computation built behind the soil sealing toolbox. The combination of GPU computing with webGIS infrastructures is relatively novel and required particular attention at the Java-CUDA programming interface. As a result, Soil Monitor is smart because it can perform very high time-consuming calculations (querying for instance an Italian administrative region as area of interest) in less than one minute. The web application is embedded in a web browser and nothing must be installed before using it. Potentially everybody can use it, but the main targets are the

  4. Effects on work ability, job strain and quality of life of monitoring depression using a self-assessment instrument in recurrent general practitioner consultations: A randomized controlled study.

    Science.gov (United States)

    Petersson, E-L; Wikberg, C; Westman, J; Ariai, N; Nejati, S; Björkelund, C

    2018-05-01

    Depression reduces individuals' function and work ability and is associated with both frequent and long-term sickness absence. Investigate if monitoring of depression course using a self-assessment instrument in recurrent general practitioner (GP) consultations leads to improved work ability, decreased job strain, and quality of life among primary care patients. Primary care patients n = 183, who worked. In addition to regular treatment (control group), intervention patients received evaluation and monitoring and used the MADRS-S depression scale during GP visit at baseline and at visits 4, 8, and 12 weeks. Work ability, quality of life and job strain were outcome measures. Depression symptoms decreased in all patients. Significantly steeper increase of WAI at 3 months in the intervention group. Social support was perceived high in a significantly higher frequency in intervention group compared to control group. Monitoring of depression course using a self-assessment instrument in recurrent GP consultations seems to lead to improved self-assessed work ability and increased high social support, but not to reduced job strain or increased quality of life compared to TAU. Future studies concerning rehabilitative efforts that seek to influence work ability probably also should include more active interventions at the workplace.

  5. Chemical Explosion Experiments to Improve Nuclear Test Monitoring - Developing a New Paradigm for Nuclear Test Monitoring with the Source Physics Experiments (SPE)

    International Nuclear Information System (INIS)

    Snelson, Catherine M.; Abbott, Robert E.; Broome, Scott T.; Mellors, Robert J.; Patton, Howard J.; Sussman, Aviva J.; Townsend, Margaret J.; Walter, William R.

    2013-01-01

    A series of chemical explosions, called the Source Physics Experiments (SPE), is being conducted under the auspices of the U.S. Department of Energy's National Nuclear Security Administration (NNSA) to develop a new more physics-based paradigm for nuclear test monitoring. Currently, monitoring relies on semi-empirical models to discriminate explosions from earthquakes and to estimate key parameters such as yield. While these models have been highly successful monitoring established test sites, there is concern that future tests could occur in media and at scale depths of burial outside of our empirical experience. This is highlighted by North Korean tests, which exhibit poor performance of a reliable discriminant, mb:Ms (Selby et al., 2012), possibly due to source emplacement and differences in seismic responses for nascent and established test sites. The goal of SPE is to replace these semi-empirical relationships with numerical techniques grounded in a physical basis and thus applicable to any geologic setting or depth

  6. Analysis of the monitoring system for the spallation neutron source 'SINQ'

    International Nuclear Information System (INIS)

    Badreddin, E.

    1998-01-01

    Petri Net models (PN) and Fault-Tree Analysis (FTA) are employed for the purpose of reliability analysis of the spallation neutron source SINQ. The monitoring and shut-down system (SDS) structure is investigated using a Petri-Net model. The reliability data are processed using a Fault-Tree model of the dominant part. Finally, suggestions for the improvement of system availability are made. (author)

  7. GEM-based thermal neutron beam monitors for spallation sources

    International Nuclear Information System (INIS)

    Croci, G.; Claps, G.; Caniello, R.; Cazzaniga, C.; Grosso, G.; Murtas, F.; Tardocchi, M.; Vassallo, E.; Gorini, G.; Horstmann, C.; Kampmann, R.; Nowak, G.; Stoermer, M.

    2013-01-01

    The development of new large area and high flux thermal neutron detectors for future neutron spallation sources, like the European Spallation Source (ESS) is motivated by the problem of 3 He shortage. In the framework of the development of ESS, GEM (Gas Electron Multiplier) is one of the detector technologies that are being explored as thermal neutron sensors. A first prototype of GEM-based thermal neutron beam monitor (bGEM) has been built during 2012. The bGEM is a triple GEM gaseous detector equipped with an aluminum cathode coated by 1μm thick B 4 C layer used to convert thermal neutrons to charged particles through the 10 B(n, 7 Li)α nuclear reaction. This paper describes the results obtained by testing a bGEM detector at the ISIS spallation source on the VESUVIO beamline. Beam profiles (FWHM x =31 mm and FWHM y =36 mm), bGEM thermal neutron counting efficiency (≈1%), detector stability (3.45%) and the time-of-flight spectrum of the beam were successfully measured. This prototype represents the first step towards the development of thermal neutrons detectors with efficiency larger than 50% as alternatives to 3 He-based gaseous detectors

  8. Control coordination abilities in shock combat sports

    Directory of Open Access Journals (Sweden)

    Natalya Boychenko

    2014-12-01

    Full Text Available Purpose: optimize the process control level of coordination abilities in martial arts. Material and Methods: analysis and compilation of scientific and methodological literature, interviews with coaches of drum martial arts, video analysis techniques, teacher observations. Results: identified specific types of coordination abilities in shock combat sports. Pod branny and offered specific and nonspecific tests to monitor the level of species athletes coordination abilities. Conclusion: it is determined that in order to achieve victory in the fight martial artists to navigate the space to be able to assess and manage dynamic and spatio-temporal parameters of movements, maintain balance, have a high coordination of movements. The proposed tests to monitor species coordination abilities athletes allow an objective assessment of not only the overall level of coordination, and the level of specific types of manifestations of this ability.

  9. Applications of Ground-based Mobile Atmospheric Monitoring: Real-time Characterization of Source Emissions and Ambient Concentrations

    Science.gov (United States)

    Goetz, J. Douglas

    Gas and particle phase atmospheric pollution are known to impact human and environmental health as well as contribute to climate forcing. While many atmospheric pollutants are regulated or controlled in the developed world uncertainty still remains regarding the impacts from under characterized emission sources, the interaction of anthropogenic and naturally occurring pollution, and the chemical and physical evolution of emissions in the atmosphere, among many other uncertainties. Because of the complexity of atmospheric pollution many types of monitoring have been implemented in the past, but none are capable of perfectly characterizing the atmosphere and each monitoring type has known benefits and disadvantages. Ground-based mobile monitoring with fast-response in-situ instrumentation has been used in the past for a number of applications that fill data gaps not possible with other types of atmospheric monitoring. In this work, ground-based mobile monitoring was implemented to quantify emissions from under characterized emission sources using both moving and portable applications, and used in a novel way for the characterization of ambient concentrations. In the Marcellus Shale region of Pennsylvania two mobile platforms were used to estimate emission rates from infrastructure associated with the production and transmission of natural gas using two unique methods. One campaign investigated emissions of aerosols, volatile organic compounds (VOCs), methane, carbon monoxide (CO), nitrogen dioxide (NO2), and carbon dioxide (CO 2) from natural gas wells, well development practices, and compressor stations using tracer release ratio methods and a developed fenceline tracer release correction factor. Another campaign investigated emissions of methane from Marcellus Shale gas wells and infrastructure associated with two large national transmission pipelines using the "Point Source Gaussian" method described in the EPA OTM-33a. During both campaigns ambient concentrations

  10. Operational Forest Monitoring in Siberia Using Multi-source Earth Observation Data

    Directory of Open Access Journals (Sweden)

    C. Hüttich

    2014-08-01

    Full Text Available Forest cover disturbance rates are increasing in the forests of Siberia due to intensification of human activities and climate change. In this paper two satellite data sources were used for automated forest cover change detection. Annual ALOS PALSAR backscatter mosaics (2007–2010 were used for yearly forest loss monitoring. Time series of the Enhanced Vegetation Index (EVI, 2000–2014 from the Moderate Resolution Imaging Spectroradiometer (MODIS were integrated in a web-based data middleware system to assess the capabilities of a near-real time detection of forest disturbances using the break point detection by additive season and trends (Bfast method. The SAR-based average accuracy of the forest loss detection was 70 %, whereas the MODIS-based change assessment using breakpoint detection achieved average accuracies of 50 % for trend-based breakpoints and 43.4 % for season-based breakpoints. It was demonstrated that SAR remote sensing is a highly accurate tool for up-to-date forest monitoring. Web-based data middleware systems like the Earth Observation Monitor, linked with MODIS time series, provide access and easy-to-use tools for on demand change monitoring in remote Siberian forests.

  11. Air pollution sources, impact and monitoring

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    1999-01-01

    Improper management of socio-economic developmental activities has put a great stress on natural resources and eco-systems and has caused environmental degradation. Indiscriminate release of toxic substances into the atmosphere from power generation, industrial operations, transportation, incineration of waste and other operations has affected the quality of ambient air. Combustion of fossil fuel results in the emission of oxides of carbon, sulfur and nitrogen, particulate and organic compounds which affect the local, regional and global environment. Industrial operations release a wide variety of pollutants which directly affect the local environment. Operation of automobiles releases oxides of carbon, sulfur and nitrogen, hydrocarbons, traces of heavy metals and toxic polycyclic aromatic compounds whereas incineration of municipal waste releases particulate, acid fumes and photochemically reactive and odorous compounds. These air pollutants have varying impacts on health and environment. The intake of polluted air may produce various physiological disorders ranging from respiratory diseases to changes in blood chemistry. Therefore, the emission of pollutants should be controlled at the source and monitoring the levels of pollution should assess the quality of air. (author)

  12. Smart x-ray beam position monitor system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Shu, D.; Kuzay, T.

    1996-01-01

    In third-generation synchrotron radiation sources, such as the Advanced Photon Source (APS), the sensitivity and reliability requirements for the x-ray beam position monitors (XBPMs) are much higher than for earlier systems. Noise and contamination signals caused by radiation emitted from the bending magnet become a major problem. The regular XBPM calibration process can only provide signal correction for one set of conditions for the insertion devices (ID). During normal operation, parameters affecting the ID-emitted beam, such as the gap of the ID magnets and the beam current, are the variables. A new smart x-ray beam position monitor system (SBPM) has been conceived and designed for the APS. It has a built in self-learning structure with EEPROM memory that is large enough to open-quote open-quote remember close-quote close-quote a complete set of calibration data covering all the possible operating conditions. During the self-learning mode, the monitor system initializes a series of automatic scan motions with information for different ID setups and records them into the database array. During normal operation, the SBPM corrects the normalized output according to the ID setup information and the calibration database. So that, with this novel system, the SBPM is always calibrating itself with the changing ID set up conditions. copyright 1996 American Institute of Physics

  13. Long-term monitoring on environmental disasters using multi-source remote sensing technique

    Science.gov (United States)

    Kuo, Y. C.; Chen, C. F.

    2017-12-01

    Environmental disasters are extreme events within the earth's system that cause deaths and injuries to humans, as well as causing damages and losses of valuable assets, such as buildings, communication systems, farmlands, forest and etc. In disaster management, a large amount of multi-temporal spatial data is required. Multi-source remote sensing data with different spatial, spectral and temporal resolutions is widely applied on environmental disaster monitoring. With multi-source and multi-temporal high resolution images, we conduct rapid, systematic and seriate observations regarding to economic damages and environmental disasters on earth. It is based on three monitoring platforms: remote sensing, UAS (Unmanned Aircraft Systems) and ground investigation. The advantages of using UAS technology include great mobility and availability in real-time rapid and more flexible weather conditions. The system can produce long-term spatial distribution information from environmental disasters, obtaining high-resolution remote sensing data and field verification data in key monitoring areas. It also supports the prevention and control on ocean pollutions, illegally disposed wastes and pine pests in different scales. Meanwhile, digital photogrammetry can be applied on the camera inside and outside the position parameters to produce Digital Surface Model (DSM) data. The latest terrain environment information is simulated by using DSM data, and can be used as references in disaster recovery in the future.

  14. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  15. Monitoring the Environments We Depend On

    International Nuclear Information System (INIS)

    Madsen, Michael

    2013-01-01

    Our overuse of natural resources, pollution and climate change are weakening natural systems’ ability to adapt to ever more sources of stress. The varied environments of our planet are interconnected and the pollution of one has ramifications across all. It is thus important to monitor the health of our environment to ensure a sustainable future. The IAEA, through its Environment Laboratories, Water Resource Programme, and technical cooperation programme, applies unique, versatile and cost-effective isotopic and nuclear techniques to understand many of the key environmental mechanisms needed to ensure a sustainable future. These monitoring systems help Member States make ecologically-responsible and scientifically-grounded development decisions

  16. Activities and Issues in Monitoring Scrap Metal Against Radioactive Sources

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S.Y., E-mail: sychen@anl.gov [Argonne National Laboratory, Argonne, IL (United States)

    2011-07-15

    Over the past few decades, the global scrap metal industry has grown increasingly vigilant regarding radioactive contamination. Accidental melts of radioactive sources in some smelting facilities, in particular, have caused considerable damage and required recovery efforts costing tens of millions of dollars. In response, the industry has developed and deployed countermeasures. Increasingly expensive and sophisticated radiation monitoring devices have been implemented at key scrap entry points - ports and scrapyards. Recognition of the importance of such endeavors has led to a series of activities aimed at establishing organized and coordinated efforts among the interested parties. Recent concerns over the potential use of radioactive sources for radiological devices in terrorist acts have substantially heightened the need for national and international authorities to further control, intercept, and secure the sources that have escaped the regulatory domain. Enhanced collaboration by the government and industry could substantially improve the effectiveness of efforts at control; the 'Spanish Protocol' as developed by the Spanish metal industry and government regulators is a good example of such collaboration. (author)

  17. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    Directory of Open Access Journals (Sweden)

    Nick Baker

    2017-03-01

    Full Text Available In fast switching power semiconductors, the use of a fourth terminal to provide the reference potential for the gate signal—known as a kelvin-source terminal—is becoming common. The introduction of this terminal presents opportunities for condition monitoring systems. This article demonstrates how the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal-Oxide-Semiconductor-Field-Effect Transistors (MOSFETs, it is shown that there are opposing trends in the evolution of the on-state resistances of both the bond-wires and the MOSFET die. In summary, after 50,000 temperature cycles, the resistance of the bond-wires increased by up to 2 mΩ, while the on-state resistance of the MOSFET dies decreased by approximately 1 mΩ. The conventional failure precursor (monitoring a single forward voltage cannot distinguish between semiconductor die or bond-wire degradation. Therefore, the ability to monitor both these parameters due to the presence of an auxiliary-source terminal can provide more detailed information regarding the aging process of a device.

  18. Monitoring of conditions inside gas aggregation cluster source during production of Ti/TiOx nanoparticles

    Science.gov (United States)

    Kousal, J.; Kolpaková, A.; Shelemin, A.; Kudrna, P.; Tichý, M.; Kylián, O.; Hanuš, J.; Choukourov, A.; Biederman, H.

    2017-10-01

    Gas aggregation sources are nowadays rather widely used in the research community for producing nanoparticles. However, the direct diagnostics of conditions inside the source are relatively scarce. In this work, we focused on monitoring the plasma parameters and the composition of the gas during the production of the TiOx nanoparticles. We studied the role of oxygen in the aggregation process and the influence of the presence of the particles on the plasma. The construction of the source allowed us to make a 2D map of the plasma parameters inside the source.

  19. Detection and monitoring of pollutant sources with Lidar/Dial techniques

    International Nuclear Information System (INIS)

    Gaudio, P; Gelfusa, M; Malizia, A; Parracino, S; Richetta, M; De Leo, L; Perrimezzi, C; Bellecci, C

    2015-01-01

    It's well known that air pollution due to anthropogenic sources can have adverse effects on humans and the ecosystem. Therefore, in the last years, surveying large regions of the atmosphere in an automatic way has become a strategic objective of various public health organizations for early detection of pollutant sources in urban and industrial areas.The Lidar and Dial techniques have become well established laser based methods for the remote sensing of the atmosphere. They are often implemented to probe almost any level of the atmosphere and to acquire information to validate theoretical models about different topics of atmospheric physics. They can also be used for environment surveying by monitoring particles, aerosols and molecules.The aim of the present work is to demonstrate the potential of these methods to detect pollutants emitted from local sources (such as particulate and/or chemical compounds) and to evaluate their concentration. This is exemplified with the help of experimental data acquired in an industrial area in the south of Italy by mean of experimental campaign by use of pollutants simulated source. For this purpose, two mobile systems Lidar and Dial have been developed by the authors. In this paper there will be presented the operating principles of the system and the results of the experimental campaign. (paper)

  20. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Faculty of Science, Macquarie University, Sydney, NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Korsch, Michael [CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Winchester, Wayne; Devenish, Matthew; Hobbs, Thad [Esperance Cleanup and Recovery Project, Western Australia (WA) Department of Transport, Esperance 6450 (Australia); Main, Cleve; Smith, Gerard [Animal Health Laboratory, Department of Agriculture and Food, Perth 6151, WA (Australia); Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie [Curtin University, Department of Imaging and Applied Physics, Bentley 6102, WA (Australia); Seow, Jimmy; Oxford, Cameron [Department of Environment and Conservation, Booragoon 6154, WA (Australia); Yun, Gracie; Gillam, Lindsay [Department of Health, East Perth 6004, WA (Australia); Crisp, Michelle [LED (Locals for Esperance Development), Esperance 6450, WA (Australia)

    2012-01-15

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. - Highlights: Black-Right-Pointing-Triangle Lead carbonate concentrate. Black-Right-Pointing-Triangle Successful use of Pb isotopes in identifying sources of Pb arising from transport and shipping. Black-Right-Pointing-Triangle Use of Pb isotopes in legal proceedings and their use in cleanup of residences. Black

  1. The source of monoenergetic electrons for the monitoring of spectrometer in the KATRIN neutrino experiment

    CERN Document Server

    Slezák, Martin

    The international project KATRIN (KArlsruhe TRItium Neutrino experiment) is a next-generation tritium $\\beta$-decay experiment. It is designed to measure the electron anti-neutrino mass by means of a unique electron spectrometer with sensitivity of 0.2 eV/c$^2$. This is an improvement of one order of magnitude over the last results. Important part of the measurement will rest in continuous precise monitoring of high voltage of the KATRIN main spectrometer. The monitoring will be done by means of conversion electrons emitted from a solid source based on $^{83}$Rb decay. Properties of several of these sources are studied in this thesis by means of the semiconductor $\\gamma$-ray spectroscopy. Firstly, measurement of precise energy of the 9.4 keV nuclear transition observed in $^{83}$Rb decay, from which the energy of conversion electrons is derived, is reported. Secondly, measurement of activity distribution of the solid sources by means of the Timepix detector is described. Finally, a report on measurement of r...

  2. Monitor of ash content of coal with X-ray source

    International Nuclear Information System (INIS)

    Wawrzonek, L.

    1983-01-01

    The coal ash monitor is used on-line to measure the ash content of raw, washed and blended coals. The instrument consists of a presentation unit and electronic unit. In the presentation unit a compact layer of coal is formed and there is also a radiation measuring system. A plutonium 238 source is used and the backscattered X-rays are detected by a proportional counter. The count rate is processed in the electronic unit and displayed as the ash percentage in the coal. A wide range of Polish coals was analysed. The monitor was tested in a power plant over the period of one year. The ash content in the coal analysed was in the range 5 to 50%. The gauge readings were compared with the pyrolysis results. An accuracy of 3.2% (95% confidence limit) was reached. These results were not corrected for the free moisture content which varied in the range 5 to 15 %. (author)

  3. Building Energy Management Open Source Software

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-20

    This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring

  4. Hybrid approaches to clinical trial monitoring: Practical alternatives to 100% source data verification

    Directory of Open Access Journals (Sweden)

    Sourabh De

    2011-01-01

    Full Text Available For years, a vast majority of clinical trial industry has followed the tenet of 100% source data verification (SDV. This has been driven partly by the overcautious approach to linking quality of data to the extent of monitoring and SDV and partly by being on the safer side of regulations. The regulations however, do not state any upper or lower limits of SDV. What it expects from researchers and the sponsors is methodologies which ensure data quality. How the industry does it is open to innovation and application of statistical methods, targeted and remote monitoring, real time reporting, adaptive monitoring schedules, etc. In short, hybrid approaches to monitoring. Coupled with concepts of optimum monitoring and SDV at site and off-site monitoring techniques, it should be possible to save time required to conduct SDV leading to more available time for other productive activities. Organizations stand to gain directly or indirectly from such savings, whether by diverting the funds back to the R&D pipeline; investing more in technology infrastructure to support large trials; or simply increasing sample size of trials. Whether it also affects the work-life balance of monitors who may then need to travel with a less hectic schedule for the same level of quality and productivity can be predicted only when there is more evidence from field.

  5. Hybrid approaches to clinical trial monitoring: Practical alternatives to 100% source data verification.

    Science.gov (United States)

    De, Sourabh

    2011-07-01

    For years, a vast majority of clinical trial industry has followed the tenet of 100% source data verification (SDV). This has been driven partly by the overcautious approach to linking quality of data to the extent of monitoring and SDV and partly by being on the safer side of regulations. The regulations however, do not state any upper or lower limits of SDV. What it expects from researchers and the sponsors is methodologies which ensure data quality. How the industry does it is open to innovation and application of statistical methods, targeted and remote monitoring, real time reporting, adaptive monitoring schedules, etc. In short, hybrid approaches to monitoring. Coupled with concepts of optimum monitoring and SDV at site and off-site monitoring techniques, it should be possible to save time required to conduct SDV leading to more available time for other productive activities. Organizations stand to gain directly or indirectly from such savings, whether by diverting the funds back to the R&D pipeline; investing more in technology infrastructure to support large trials; or simply increasing sample size of trials. Whether it also affects the work-life balance of monitors who may then need to travel with a less hectic schedule for the same level of quality and productivity can be predicted only when there is more evidence from field.

  6. WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

    Energy Technology Data Exchange (ETDEWEB)

    Bevins, N; Vanderhoek, M; Lang, S; Flynn, M [Henry Ford Health System, Detroit, MI (United States)

    2014-06-15

    Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

  7. WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

    International Nuclear Information System (INIS)

    Bevins, N; Vanderhoek, M; Lang, S; Flynn, M

    2014-01-01

    Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system

  8. Strategies for satellite-based monitoring of CO2 from distributed area and point sources

    Science.gov (United States)

    Schwandner, Florian M.; Miller, Charles E.; Duren, Riley M.; Natraj, Vijay; Eldering, Annmarie; Gunson, Michael R.; Crisp, David

    2014-05-01

    and sensor provides the full range of temporal sampling needed to characterize distributed area and point source emissions. For instance, point source emission patterns will vary with source strength, wind speed and direction. Because wind speed, direction and other environmental factors change rapidly, short term variabilities should be sampled. For detailed target selection and pointing verification, important lessons have already been learned and strategies devised during JAXA's GOSAT mission (Schwandner et al, 2013). The fact that competing spatial and temporal requirements drive satellite remote sensing sampling strategies dictates a systematic, multi-factor consideration of potential solutions. Factors to consider include vista, revisit frequency, integration times, spatial resolution, and spatial coverage. No single satellite-based remote sensing solution can address this problem for all scales. It is therefore of paramount importance for the international community to develop and maintain a constellation of atmospheric CO2 monitoring satellites that complement each other in their temporal and spatial observation capabilities: Polar sun-synchronous orbits (fixed local solar time, no diurnal information) with agile pointing allow global sampling of known distributed area and point sources like megacities, power plants and volcanoes with daily to weekly temporal revisits and moderate to high spatial resolution. Extensive targeting of distributed area and point sources comes at the expense of reduced mapping or spatial coverage, and the important contextual information that comes with large-scale contiguous spatial sampling. Polar sun-synchronous orbits with push-broom swath-mapping but limited pointing agility may allow mapping of individual source plumes and their spatial variability, but will depend on fortuitous environmental conditions during the observing period. These solutions typically have longer times between revisits, limiting their ability to resolve

  9. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling.

    Science.gov (United States)

    McMillan, Lindsay A; Rivett, Michael O; Wealthall, Gary P; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting

  10. Monitoring well utility in a heterogeneous DNAPL source zone area: Insights from proximal multilevel sampler wells and sampling capture-zone modelling

    Science.gov (United States)

    McMillan, Lindsay A.; Rivett, Michael O.; Wealthall, Gary P.; Zeeb, Peter; Dumble, Peter

    2018-03-01

    Groundwater-quality assessment at contaminated sites often involves the use of short-screen (1.5 to 3 m) monitoring wells. However, even over these intervals considerable variation may occur in contaminant concentrations in groundwater adjacent to the well screen. This is especially true in heterogeneous dense non-aqueous phase liquid (DNAPL) source zones, where cm-scale contamination variability may call into question the effectiveness of monitoring wells to deliver representative data. The utility of monitoring wells in such settings is evaluated by reference to high-resolution multilevel sampler (MLS) wells located proximally to short-screen wells, together with sampling capture-zone modelling to explore controls upon well sample provenance and sensitivity to monitoring protocols. Field data are analysed from the highly instrumented SABRE research site that contained an old trichloroethene source zone within a shallow alluvial aquifer at a UK industrial facility. With increased purging, monitoring-well samples tend to a flow-weighted average concentration but may exhibit sensitivity to the implemented protocol and degree of purging. Formation heterogeneity adjacent to the well-screen particularly, alongside pump-intake position and water level, influence this sensitivity. Purging of low volumes is vulnerable to poor reproducibility arising from concentration variability predicted over the initial 1 to 2 screen volumes purged. Marked heterogeneity may also result in limited long-term sample concentration stabilization. Development of bespoke monitoring protocols, that consider screen volumes purged, alongside water-quality indicator parameter stabilization, is recommended to validate and reduce uncertainty when interpreting monitoring-well data within source zone areas. Generalised recommendations on monitoring well based protocols are also developed. A key monitoring well utility is their proportionately greater sample draw from permeable horizons constituting a

  11. Real breakthrough in detection of radioactive sources by portal monitors with plastic detectors and New Advanced Source Identification Algorithm (ASIA-New)

    Energy Technology Data Exchange (ETDEWEB)

    Stavrov, Andrei; Yamamoto, Eugene [Rapiscan Systems, Inc., 14000 Mead Street, Longmont, CO, 80504 (United States)

    2015-07-01

    Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the Rapiscan company. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co- 57, Ba-133 and other). New variant of ASIA is based on physical principles, a phenomenological approach and analysis of some important parameter changes during the vehicle passage through the monitor control area. Thanks to this capability main advantage of new system is that this system can be easily installed into any RPM with plastic detectors. Taking into account that more than 4000 RPM has been installed worldwide their upgrading by ASIA-New may significantly increase probability of detection and verification of radioactive sources even masked by NORM. This algorithm was tested for 1,395 passages of

  12. Monitoring of diesel engine combustions based on the acoustic source characterisation of the exhaust system

    Science.gov (United States)

    Jiang, J.; Gu, F.; Gennish, R.; Moore, D. J.; Harris, G.; Ball, A. D.

    2008-08-01

    Acoustic methods are among the most useful techniques for monitoring the condition of machines. However, the influence of background noise is a major issue in implementing this method. This paper introduces an effective monitoring approach to diesel engine combustion based on acoustic one-port source theory and exhaust acoustic measurements. It has been found that the strength, in terms of pressure, of the engine acoustic source is able to provide a more accurate representation of the engine combustion because it is obtained by minimising the reflection effects in the exhaust system. A multi-load acoustic method was then developed to determine the pressure signal when a four-cylinder diesel engine was tested with faults in the fuel injector and exhaust valve. From the experimental results, it is shown that a two-load acoustic method is sufficient to permit the detection and diagnosis of abnormalities in the pressure signal, caused by the faults. This then provides a novel and yet reliable method to achieve condition monitoring of diesel engines even if they operate in high noise environments such as standby power stations and vessel chambers.

  13. Work ability assessment in a worker population: comparison and determinants of Work Ability Index and Work Ability score.

    Science.gov (United States)

    El Fassi, Mehdi; Bocquet, Valery; Majery, Nicole; Lair, Marie Lise; Couffignal, Sophie; Mairiaux, Philippe

    2013-04-08

    Public authorities in European countries are paying increasing attention to the promotion of work ability throughout working life and the best method to monitor work ability in populations of workers is becoming a significant question. The present study aims to compare the assessment of work ability based on the use of the Work Ability Index (WAI), a 7-item questionnaire, with another one based on the use of WAI's first item, which consists in the worker's self-assessment of his/her current work ability level as opposed to his/her lifetime best, this single question being termed "Work Ability score" (WAS). Using a database created by an occupational health service, the study intends to answer the following questions: could the assessment of work ability be based on a single-item measure and which are the variables significantly associated with self-reported work ability among those systematically recorded by the occupational physician during health examinations? A logistic regression model was used in order to estimate the probability of observing "poor" or "moderate" WAI levels depending on age, gender, body mass index, smoking status, position held, firm size and diseases reported by the worker in a population of workers aged 40 to 65 and examined between January 2006 and June 2010 (n=12389). The convergent validity between WAS and WAI was statistically significant (rs=0.63). In the multivariable model, age (pwork ability. A work position characterized by the predominance of mental activity (OR=0.71, 95%CI [0.61-0.84]) had a favourable impact on work ability. These relations were observed regardless of the work ability measurement tool used. The convergent validity and the similarity in results between WAI and WAS observed in a large population of employed workers should thus foster the use of WAS for systematic screening of work ability. Ageing, overweight, decline in health status, holding a mostly physical job and working in a large-sized firm increase the

  14. Schema bias in source monitoring varies with encoding conditions: support for a probability-matching account.

    Science.gov (United States)

    Kuhlmann, Beatrice G; Vaterrodt, Bianca; Bayen, Ute J

    2012-09-01

    Two experiments examined reliance on schematic knowledge in source monitoring. Based on a probability-matching account of source guessing, a schema bias will only emerge if participants do not have a representation of the source-item contingency in the study list, or if the perceived contingency is consistent with schematic expectations. Thus, the account predicts that encoding conditions that affect contingency detection also affect schema bias. In Experiment 1, the schema bias commonly found when schematic information about the sources is not provided before encoding was diminished by an intentional source-memory instruction. In Experiment 2, the depth of processing of schema-consistent and schema-inconsistent source-item pairings was manipulated. Participants consequently overestimated the occurrence of the pairing type they processed in a deep manner, and their source guessing reflected this biased contingency perception. Results support the probability-matching account of source guessing. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  15. Do motor ability and handwriting kinematic measures predict organizational ability among children with Developmental Coordination Disorders?

    Science.gov (United States)

    Rosenblum, Sara

    2015-10-01

    Children with Developmental Coordination Disorders (DCD) exhibit deficient daily performance concealed in their perception-action mechanism. The aim of this study was to analyze behavior organization of children with DCD, in varied tasks that require generating and monitoring mental representations related to space and time inputs/requirements, for achieving better insight about their perception-action mechanism. Participants included 42 children aged 7-10, half of whom were defined with DCD and half were typically developing (TD). The children were matched for age, gender and school. They were evaluated using the Movement-ABC and performed three handwriting tasks on an electronic tablet that is part of a computerized system (ComPET - Computerized Penmanship Evaluation Tool). In addition, their teachers completed the Questionnaire for Assessing Students' Organizational Abilities-Teachers (QASOA-T) to assess the children's daily organizational ability. Significant group differences (DCD versus controls) were found for all handwriting kinematic measures across the three handwriting tasks and for the children's organizational abilities. Motor ability predicted a considerable percentage of the variance of the kinematic handwriting measures (30-37%), as well as a high percentage of the variance of their organizational abilities (67%). The coefficient of variance of the pen tilt added an additional 3% to the prediction of their organizational abilities. The results of this study exhibited deficient ability among children with DCD in organizing their behavior in varied real-world tasks requiring generation and monitoring representation related to space and time. The significance of the results to understanding the performance mechanism and implication to the clinical field are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  17. Frequent VLBI Monitoring on Parsec-Scales of 450+ Extragalactic FERMI Sources at 8 and 32 GHz

    Science.gov (United States)

    Jacobs, Christopher S.; Majid, W. A.; Romero-Wolf, A.; García-Mirí, C.; Horiuchi, S.; Snedeker, L. G.; Sotuela, I.

    2012-10-01

    Executive Summary: An existing Ka-band (32 GHz, 9mm) catalog of 450+ sources is being monitored every 6-10 weeks on Giga-lambda baselines. These observations are sensitive to parsec scale activity in the AGN cores providing unique tests of gamma ray emission models. Abstract: The Fermi Large Area Telescope (LAT) has now released the 2nd catalog of high-energy gamma-ray sources (2FGL) derived from the first 24 months of mission science data with 1873 sources detected and characterized in the 100 MeV to 100 GeV range. 1017 of 1873 sources at high Galactic latitude (abs(b) > 10 degrees) are associated statistically with active galactic nuclei (AGNs). Parsec-scale VLBI measurements play an important role in characterizing the nature of the candidate AGNs by providing crucial extra information to improve the probability of correct identification - VLBI filters out objects which do not host strong compact jets at parsec scale. We are carrying out regular VLBI monitoring of 450+ compact extragalactic sources using Deep Space Network (DSN) 34-meter antennas over intercontinental baselines simultaneously at 8 and 32 GHz. In addition to precision astrometric measurements of AGN compact cores used to maintain the JPL extragalactic reference frame, this program has the potential to provide regular simultaneous flux density measurements at 8 and 32 GHz with precision level of ~20%. By providing measurements on both East-West and North-South baselines with large antennas and Gbit/s recording capability, our program can probe sources down to a flux limit of 30 mJy (10-sigma), potentially increasing the sample to a fainter population of sources. In these regards, our program complements well existing northern and southern hemisphere VLBI monitoring programs, by providing flux measurements at 32 GHz, covering a fainter population sample, and by filling the gap for sources in the -20 to -45 degree declination range. Further, our program also provides additional flexibility for

  18. Source term assessment using inverse modeling of radiation dose measured with environmental radiation monitors located at different positions

    International Nuclear Information System (INIS)

    Srinivas, C.V.; Rakesh, P.T.; Baskaran, R.; Venkatraman, B.

    2018-01-01

    Source term is an important input for consequence analysis using Decision Support Systems (DSS) to project radiological impact in the event of nuclear emergencies. A source term model called 'ASTER' is incorporated in the Online Nuclear Emergency Response System (ONERS) operational at Kalpakkam site for decision making during nuclear emergencies. This computes release rates using inverse method by employing an atmospheric dispersion model and gamma dose rates measured by environmental radiation monitors (ERM) deployed around the nuclear plant. The estimates may depend on the distribution of ERMs around the release location. In this work, data from various gamma monitors located at different radii 0.75 km and 1.5 km is used to assess the accuracy in the source term estimation for stack releases of MAPS-PHWR at Kalpakkam

  19. Wearable Sensor Localization Considering Mixed Distributed Sources in Health Monitoring Systems.

    Science.gov (United States)

    Wan, Liangtian; Han, Guangjie; Wang, Hao; Shu, Lei; Feng, Nanxing; Peng, Bao

    2016-03-12

    In health monitoring systems, the base station (BS) and the wearable sensors communicate with each other to construct a virtual multiple input and multiple output (VMIMO) system. In real applications, the signal that the BS received is a distributed source because of the scattering, reflection, diffraction and refraction in the propagation path. In this paper, a 2D direction-of-arrival (DOA) estimation algorithm for incoherently-distributed (ID) and coherently-distributed (CD) sources is proposed based on multiple VMIMO systems. ID and CD sources are separated through the second-order blind identification (SOBI) algorithm. The traditional estimating signal parameters via the rotational invariance technique (ESPRIT)-based algorithm is valid only for one-dimensional (1D) DOA estimation for the ID source. By constructing the signal subspace, two rotational invariant relationships are constructed. Then, we extend the ESPRIT to estimate 2D DOAs for ID sources. For DOA estimation of CD sources, two rational invariance relationships are constructed based on the application of generalized steering vectors (GSVs). Then, the ESPRIT-based algorithm is used for estimating the eigenvalues of two rational invariance matrices, which contain the angular parameters. The expressions of azimuth and elevation for ID and CD sources have closed forms, which means that the spectrum peak searching is avoided. Therefore, compared to the traditional 2D DOA estimation algorithms, the proposed algorithm imposes significantly low computational complexity. The intersecting point of two rays, which come from two different directions measured by two uniform rectangle arrays (URA), can be regarded as the location of the biosensor (wearable sensor). Three BSs adopting the smart antenna (SA) technique cooperate with each other to locate the wearable sensors using the angulation positioning method. Simulation results demonstrate the effectiveness of the proposed algorithm.

  20. Pan-tropical monitoring of deforestation

    International Nuclear Information System (INIS)

    Achard, F; DeFries, R; Eva, H; Hansen, M; Mayaux, P; Stibig, H-J

    2007-01-01

    This paper reviews the technical capabilities for monitoring deforestation from a pan-tropical perspective in response to the United Nations Framework Convention on Climate Change (UNFCCC) process, which is studying the technical issues surrounding the ability to reduce greenhouse gas emissions from deforestation in developing countries. The successful implementation of such policies requires effective forest monitoring systems that are reproducible, provide consistent results, meet standards for mapping accuracy, and can be implemented from national to pan-tropical levels. Remotely sensed data, supported by ground observations, are crucial to such efforts. Recent developments in global to regional monitoring of forests can contribute to reducing the uncertainties in estimates of emissions from deforestation. Monitoring systems at national levels in developing countries can also benefit from pan-tropical and regional observations, mainly by identifying hot spots of change and prioritizing areas for monitoring at finer spatial scales. A pan-tropical perspective is also required to ensure consistency between different national monitoring systems. Data sources already exist to determine baseline periods in the 1990s as historical reference points. Key requirements for implementing such monitoring programs, both at pan-tropical and at national scales, are international commitment of resources to increase capacity, coordination of observations to ensure pan-tropical coverage, access to free or low-cost data, and standardized, consensus protocols for data interpretation and analysis

  1. Environmental perverse incentives in coastal monitoring.

    Science.gov (United States)

    Gibbs, Mark T

    2013-08-15

    It can be argued that the intensity of monitoring of coastal marine environments lags behind the equivalent terrestrial environments. This results in a paucity of long-term time series of key environmental parameters such as turbidity. This lack of management information of the sources and sinks, and causes and impacts of stressors to the coastal marine environment, along with a lack of co-ordination of information collection is compromising the ability of environmental impact assessments of major coastal developments to discriminate between local and remote anthropogenic impacts, and natural or background processes. In particular, the quasi outsourcing of the collection of coastal information can lead to a perverse incentive whereby in many cases nobody is actively or consistently monitoring the coastal marine environment effectively. This is particularly the case with regards to the collection of long-term and whole-of-system scale data. This lack of effective monitoring can act to incentivise poor environmental performance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. [Experimental research on the electromagnetic radiation immunity of a kind of portable monitor].

    Science.gov (United States)

    Yuan, Jun; Xiao, Dongping; Jian, Xin

    2010-11-01

    The paper is focused on a kind of portable monitor that is widely used in military hospitals. In order to study the electromagnetic radiation immunity of the monitor, the experiments of electromagnetic radiation caused by radio frequency continuous wave in reverberation chamber and by ultra wide band (UWB) electromagnetic pulse have been done. The study results show that UWB electromagnetic pulse interferes observably the operating state of the monitor. It should be paid high attention to take protective measures. The monitor tested has some electromagnetic immunity ability for radio frequency continuous wave radiation. The frequent abnormal phenomena are baseline drift and waveform distortion. The electromagnetic sensitivity of the monitor is related to the frequency of interference source. The monitor tested is most sensitive to the frequency of 390 MHz.

  3. The affective reactivity of psychotic speech: The role of internal source monitoring in explaining increased thought disorder under emotional challenge.

    Science.gov (United States)

    de Sousa, Paulo; Sellwood, William; Spray, Amy; Bentall, Richard P

    2016-04-01

    Thought disorder (TD) has been shown to vary in relation to negative affect. Here we examine the role internal source monitoring (iSM, i.e. ability to discriminate between inner speech and verbalized speech) in TD and whether changes in iSM performance are implicated in the affective reactivity effect (deterioration of TD when participants are asked to talk about emotionally-laden topics). Eighty patients diagnosed with schizophrenia-spectrum disorder and thirty healthy controls received interviews that promoted personal disclosure (emotionally salient) and interviews on everyday topics (non-salient) on separate days. During the interviews, participants were tested on iSM, self-reported affect and immediate auditory recall. Patients had more TD, poorer ability to discriminate between inner and verbalized speech, poorer immediate auditory recall and reported more negative affect than controls. Both groups displayed more TD and negative affect in salient interviews but only patients showed poorer performance on iSM. Immediate auditory recall did not change significantly across affective conditions. In patients, the relationship between self-reported negative affect and TD was mediated by deterioration in the ability to discriminate between inner speech and speech that was directed to others and socially shared (performance on the iSM) in both interviews. Furthermore, deterioration in patients' performance on iSM across conditions significantly predicted deterioration in TD across the interviews (affective reactivity of speech). Poor iSM is significantly associated with TD. Negative affect, leading to further impaired iSM, leads to increased TD in patients with psychosis. Avenues for future research as well as clinical implications of these findings are discussed. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Generic procedures for monitoring in a nuclear or radiological emergency

    International Nuclear Information System (INIS)

    1999-06-01

    One of the most important aspects of managing a radiological emergency is the ability to promptly and adequately assess the need for protective actions. Protective action accident management must make use of the key relevant information available. Decision-making and accident assessment will be an iterative and dynamic process aimed at refining the initial evaluation as more detailed and complete information becomes available. Emergency monitoring is one of the main sources for obtaining needed information. This publication is in the scope of the Convention on Assistance in the Case of a Nuclear Accident or Radiological Emergency (Legal Series No. 14) under which the IAEA is authorized to assist a State Party or a Member State among other matters in developing appropriate radiation monitoring programmes, procedures and standards (Article 5). The scope of this manual is restricted to practical guidance for environmental and source monitoring during a nuclear or other radiological emergency. It does not address emergency response preparedness, nor does it cover the emergency management aspects of accident assessment. This manual is organised into sections relating to measurements in order of priority of a major reactor accident, namely: ambient gamma/beta dose rates from plume, ground deposition or source; radionuclide concentrations in air; deposition maps for 131 I and 137 Cs and other important radionuclides; radionuclide mix in deposition and radionuclide concentrations in food, drinking water and other samples. The introductory section provides an overview of the design of emergency monitoring and sampling programmes, monitoring teams and their qualifications and training, monitoring equipment and instrumentation, protective actions for emergency monitoring teams and quality assurance and quality control checks

  5. Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS

    Science.gov (United States)

    Decker, Glenn; Rosenbaum, Gerd; Singh, Om

    2006-11-01

    Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.

  6. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL

    2008-12-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.

  7. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    International Nuclear Information System (INIS)

    Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.

    2008-01-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies

  8. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring.

    Science.gov (United States)

    Gulson, Brian; Korsch, Michael; Winchester, Wayne; Devenish, Matthew; Hobbs, Thad; Main, Cleve; Smith, Gerard; Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie; Seow, Jimmy; Oxford, Cameron; Yun, Gracie; Gillam, Lindsay; Crisp, Michelle

    2012-01-01

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  9. Gully Erosion Mapping and Monitoring at Multiple Scales Based on Multi-Source Remote Sensing Data of the Sancha River Catchment, Northeast China

    Directory of Open Access Journals (Sweden)

    Ranghu Wang

    2016-11-01

    Full Text Available This research is focused on gully erosion mapping and monitoring at multiple spatial scales using multi-source remote sensing data of the Sancha River catchment in Northeast China, where gullies extend over a vast area. A high resolution satellite image (Pleiades 1A, 0.7 m was used to obtain the spatial distribution of the gullies of the overall basin. Image visual interpretation with field verification was employed to map the geometric gully features and evaluate gully erosion as well as the topographic differentiation characteristics. Unmanned Aerial Vehicle (UAV remote sensing data and the 3D photo-reconstruction method were employed for detailed gully mapping at a site scale. The results showed that: (1 the sub-meter image showed a strong ability in the recognition of various gully types and obtained satisfactory results, and the topographic factors of elevation, slope and slope aspects exerted significant influence on the gully spatial distribution at the catchment scale; and (2 at a more detailed site scale, UAV imagery combined with 3D photo-reconstruction provided a Digital Surface Model (DSM and ortho-image at the centimeter level as well as a detailed 3D model. The resulting products revealed the area of agricultural utilization and its shaping by human agricultural activities and water erosion in detail, and also provided the gully volume. The present study indicates that using multi-source remote sensing data, including satellite and UAV imagery simultaneously, results in an effective assessment of gully erosion over multiple spatial scales. The combined approach should be continued to regularly monitor gully erosion to understand the erosion process and its relationship with the environment from a comprehensive perspective.

  10. Structural Health Monitoring of Wind Turbine Blades: Acoustic Source Localization Using Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Omar Mabrok Bouzid

    2015-01-01

    Full Text Available Structural health monitoring (SHM is important for reducing the maintenance and operation cost of safety-critical components and systems in offshore wind turbines. This paper proposes an in situ wireless SHM system based on an acoustic emission (AE technique. By using this technique a number of challenges are introduced due to high sampling rate requirements, limitations in the communication bandwidth, memory space, and power resources. To overcome these challenges, this paper focused on two elements: (1 the use of an in situ wireless SHM technique in conjunction with the utilization of low sampling rates; (2 localization of acoustic sources which could emulate impact damage or audible cracks caused by different objects, such as tools, bird strikes, or strong hail, all of which represent abrupt AE events and could affect the structural health of a monitored wind turbine blade. The localization process is performed using features extracted from aliased AE signals based on a developed constraint localization model. To validate the performance of these elements, the proposed system was tested by testing the localization of the emulated AE sources acquired in the field.

  11. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    Science.gov (United States)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to

  12. Open source hardware solutions for low-cost, do-it-yourself environmental monitoring, citizen science, and STEM education

    Science.gov (United States)

    Hicks, S. D.; Aufdenkampe, A. K.; Horsburgh, J. S.; Arscott, D. B.; Muenz, T.; Bressler, D. W.

    2016-12-01

    The explosion in DIY open-source hardware and software has resulted in the development of affordable and accessible technologies, like drones and weather stations, that can greatly assist the general public in monitoring environmental health and its degradation. It is widely recognized that education and support of audiences in pursuit of STEM literacy and the application of emerging technologies is a challenge for the future of citizen science and for preparing high school graduates to be actively engaged in environmental stewardship. It is also clear that detecting environmental change/degradation over time and space will be greatly enhanced with expanded use of networked, remote monitoring technologies by watershed organizations and citizen scientists if data collection and reporting are properly carried out and curated. However, there are few focused efforts to link citizen scientists and school programs with these emerging tools. We have started a multi-year program to develop hardware and teaching materials for training students and citizen scientists about the use of open source hardware in environmental monitoring. Scientists and educators around the world have started building their own dataloggers and devices using a variety of boards based on open source electronics. This new hardware is now providing researchers with an inexpensive alternative to commercial data logging and transmission hardware. We will present a variety of hardware solutions using the Arduino-compatible EnviroDIY Mayfly board (http://envirodiy.org/mayfly) that can be used to build and deploy a rugged environmental monitoring station using a wide variety of sensors and options, giving the users a fully customizable device for making measurements almost anywhere. A database and visualization system is being developed that will allow the users to view and manage the data their devices are collecting. We will also present our plan for developing curricula and leading workshops to various

  13. Drug-related homicide in Europe-First review of data and sources.

    Science.gov (United States)

    de Bont, Roel; Groshkova, Teodora; Cunningham, Andrew; Liem, Marieke

    2018-04-13

    Drugs can act as facilitators for all types of violence, including drug-related homicide (DRH). Addressing this phenomenon is not only of importance given the severity of a homicide event and its high costs on society, but also because DRH has the potential to act as a valuable indicator or proxy of wider drug-related violent crime. However, there appears to be an important gap in terms of available European data on DRH. This study aimed to identify relevant European data sources on DRH, to assess the role of drugs in national homicide data, and to assess these sources and data in terms of monitoring potential. A critical review was conducted of existing national and international homicide data sources. A three-step approach was adopted, including systematic searches for data sources and literature, snowballing methods, and contacting professionals. Data on DRH is systematically prepared in the Czech Republic, Denmark, Finland, Germany, Italy, the Netherlands, Norway, Slovakia, Sweden, and the United Kingdom (England, Wales, and Scotland). Available data suggests both between- and within country variability in relation to the role of drugs in homicide events. Based on these findings, four key obstacles can be identified in terms of the current ability to monitor DRH: missing data, fragmented data, comparability issues and data quality reservations. To overcome these obstacles, there is a need for an international monitoring system that incorporates DRH. Ideally, the system should employ a single shared definition, standardised terminology, one coordinating body, and the use of multiple data sources. There are several approaches towards such a system, notably expanding the European Homicide Monitor (EHM) framework. Options should be explored to incorporate DRH into this existing and growing monitoring system. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Long-range alpha detection applied to soil contamination and waste monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; Bounds, J.A.; Close, D.A.; McAtee, J.L.

    1992-01-01

    Alpha contamination monitoring has been traditionally limited by the short range of alpha particles in air and through detector windows. The long-range alpha detector (LRAD) described in this paper circumvents that limitation by detecting alpha-produced ions, rather than alpha particles directly. Since the LRAD is sensitive to all ions, it can monitor all contamination present on a large surface at one time. Because air is the ''detector gas,'' the LRAD can detect contamination on any surface to which air can penetrate. We present data showing the sensitivity of LRAD detectors, as well as documenting their ability to detect alpha sources in previously unmonitorable locations, and verifying the ion lifetime. Specific designs and results for soil contamination and waste monitors are also included

  15. Hanford Site groundwater monitoring: Setting, sources and methods

    International Nuclear Information System (INIS)

    Hartman, M.J.

    2000-01-01

    Groundwater monitoring is conducted on the Hanford Site to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA); Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA); U.S. Department of Energy (DOE) orders; and the Washington Administrative Code. Results of monitoring are published annually (e.g., PNNL-11989). To reduce the redundancy of these annual reports, background information that does not change significantly from year to year has been extracted from the annual report and published in this companion volume. This report includes a description of groundwater monitoring requirements, site hydrogeology, and waste sites that have affected groundwater quality or that require groundwater monitoring. Monitoring networks and methods for sampling, analysis, and interpretation are summarized. Vadose zone monitoring methods and statistical methods also are described. Whenever necessary, updates to information contained in this document will be published in future groundwater annual reports

  16. Hanford Site groundwater monitoring: Setting, sources and methods

    Energy Technology Data Exchange (ETDEWEB)

    M.J. Hartman

    2000-04-11

    Groundwater monitoring is conducted on the Hanford Site to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA); Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA); U.S. Department of Energy (DOE) orders; and the Washington Administrative Code. Results of monitoring are published annually (e.g., PNNL-11989). To reduce the redundancy of these annual reports, background information that does not change significantly from year to year has been extracted from the annual report and published in this companion volume. This report includes a description of groundwater monitoring requirements, site hydrogeology, and waste sites that have affected groundwater quality or that require groundwater monitoring. Monitoring networks and methods for sampling, analysis, and interpretation are summarized. Vadose zone monitoring methods and statistical methods also are described. Whenever necessary, updates to information contained in this document will be published in future groundwater annual reports.

  17. Subjective workload and individual differences in information processing abilities

    Science.gov (United States)

    Damos, D. L.

    1984-01-01

    This paper describes several experiments examining the source of individual differences in the experience of mental workload. Three sources of such differences were examined: information processing abilities, timesharing abilities, and personality traits/behavior patterns. On the whole, there was little evidence that individual differences in information processing abilities or timesharing abilities are related to perceived differences in mental workload. However, individuals with strong Type A coronary prone behavior patterns differed in both single- and multiple-task performance from individuals who showed little evidence of such a pattern. Additionally, individuals with a strong Type A pattern showed some dissociation between objective performance and the experience of mental workload.

  18. Evaluating four-dimensional time-lapse electrical resistivity tomography for monitoring DNAPL source zone remediation.

    Science.gov (United States)

    Power, Christopher; Gerhard, Jason I; Karaoulis, Marios; Tsourlos, Panagiotis; Giannopoulos, Antonios

    2014-07-01

    Practical, non-invasive tools do not currently exist for mapping the remediation of dense non-aqueous phase liquids (DNAPLs). Electrical resistivity tomography (ERT) exhibits significant potential but has not yet become a practitioner's tool due to challenges in interpreting the survey results at real sites. This study explores the effectiveness of recently developed four-dimensional (4D, i.e., 3D space plus time) time-lapse surface ERT to monitor DNAPL source zone remediation. A laboratory experiment demonstrated the approach for mapping a changing NAPL distribution over time. A recently developed DNAPL-ERT numerical model was then employed to independently simulate the experiment, providing confidence that the DNAPL-ERT model is a reliable tool for simulating real systems. The numerical model was then used to evaluate the potential for this approach at the field scale. Four DNAPL source zones, exhibiting a range of complexity, were initially simulated, followed by modeled time-lapse ERT monitoring of complete DNAPL remediation by enhanced dissolution. 4D ERT inversion provided estimates of the regions of the source zone experiencing mass reduction with time. Results show that 4D time-lapse ERT has significant potential to map both the outline and the center of mass of the evolving treated portion of the source zone to within a few meters in each direction. In addition, the technique can provide a reasonable, albeit conservative, estimate of the DNAPL volume remediated with time: 25% underestimation in the upper 2m and up to 50% underestimation at late time between 2 and 4m depth. The technique is less reliable for identifying cleanup of DNAPL stringers outside the main DNAPL body. Overall, this study demonstrates that 4D time-lapse ERT has potential for mapping where and how quickly DNAPL mass changes in real time during site remediation. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Stability of source mechanisms inverted from P-wave amplitude microseismic monitoring data acquired at the surface

    Czech Academy of Sciences Publication Activity Database

    Staněk, František; Eisner, Leo; Moser, T.J.

    2014-01-01

    Roč. 62, č. 3 (2014), s. 475-490 ISSN 0016-8025 R&D Projects: GA ČR GAP210/12/2451 Institutional support: RVO:67985891 Keywords : microseismic monitoring * inversion * ray modelling * source mechanism Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 1.506, year: 2013

  20. Antibiotics resistance phenomenon and virulence ability in bacteria from water environment

    Directory of Open Access Journals (Sweden)

    Mohamed I. Azzam

    2017-10-01

    Full Text Available This study aims to determine the impact of five main drains as sources of antibiotics resistant bacteria in River Nile at Rosetta branch, and to generate a baseline data on their virulence ability. Out of 212 bacterial isolates, 39.2% and 60.8% were recovered from drains and Rosetta branch, respectively. Susceptibility of bacteria to different antibiotics showed multiple antibiotics resistances (MAR for the majority of isolates. Meanwhile, sensitivity was mostly directed to ofloxacin and norfloxacin antibiotics. Calculated MAR index values (>0.25 classified area of study as potentially health risk environment. Testing virulence ability of bacteria from drains showed positive results (65%. Contrastively, virulent strains in Rosetta branch were mostly lacking in this study. Concluding remarks justify the strong correlation (r = +0.82 between MAR and virulence of bacteria in polluted aquatic ecosystems, and highlight the potential of drains as reactors for their amplification and dissemination. The study suggests regular monitoring for antibiotics resistance in native bacteria of River Nile, prohibition of unregulated use of antibiotics, and proper management for wastes disposal.

  1. Active Seismic Monitoring Using High-Power Moveable 40-TONS Vibration Sources in Altay-Sayn Region of Russia

    Science.gov (United States)

    Soloviev, V. M.; Seleznev, V. S.; Emanov, A. F.; Kashun, V. N.; Elagin, S. A.; Romanenko, I.; Shenmayer, A. E.; Serezhnikov, N.

    2013-05-01

    The paper presents data of operating vibroseismic observations using high-power stationary 100-tons and moveable 40-tons vibration sources, which have been carried out in Russia for 30 years. It is shown that investigations using high-power vibration sources open new possibilities for study stressedly-deformed condition of the Earth`s crust and the upper mantle and tectonic process in them. Special attention is given to developing operating seismic translucences of the Earth`s crust and the upper mantle using high-power 40-tons vibration sources. As a result of experimental researches there was proved high stability and repeatability of vibration effects. There were carried out long period experiments of many days with vibration source sessions of every two hours with the purpose of monitoring accuracy estimation. It was determined, that repeatability of vibroseismic effects (there was researched time difference of repeated sessions of P- and S-waves from crystal rocks surface) could be estimated as 10-3 - 10-4 sec. It is ten times less than revealed here annual variations of kinematic parameters according to regime vibroseismic observations. It is shown, that on hard high-speed grounds radiation spectrum becomes narrowband and is dislocated to high frequency; at the same time quantity of multiple high-frequency harmonic is growing. At radiation on soft sedimentary grounds (sand, clay) spectrum of vibration source in near zone is more broadband, correlograms are more compact. there Correspondence of wave fields from 40-tons vibration sources and explosions by reference waves from boundaries in he Earth`s crust and the upper mantle at record distance of 400 km was proved by many experiments in various regions of Russia; there was carried out the technique of high-power vibration sources grouping for increase of effectiveness of emanation and increase of record distance. According to results of long-term vibroseismic monitoring near Novosibirsk (1997-2012) there are

  2. A Multi-Walled Carbon Nanotube-based Biosensor for Monitoring Microcystin-LR in Sources of Drinking Water Supplies

    Science.gov (United States)

    A multi-walled carbon nanotube-based electrochemical biosensor is developed for monitoring microcystin-LR (MC-LR), a toxic cyanobacterial toxin, in sources of drinking water supplies. The biosensor electrodes are fabricated using dense, mm-long multi-walled CNT (MWCNT) arrays gro...

  3. A Versatile Beam Loss Monitoring System for CLIC

    CERN Document Server

    Kastriotou, Maria; Farabolini, Wilfrid; Holzer, Eva Barbara; Nebot Del Busto, Eduardo; Tecker, Frank; Welsch, Carsten

    2016-01-01

    The design of a potential CLIC beam loss monitoring (BLM) system presents multiple challenges. To successfully cover the 48 km of beamline, ionisation chambers and optical fibre BLMs are under investigation. The former fulfils all CLIC requirements but would need more than 40000 monitors to protect the whole facility. For the latter, the capability of reconstructing the original loss position with a multi-bunch beam pulse and multiple loss locations still needs to be quantified. Two main sources of background for beam loss measurements are identified for CLIC. The two-beam accelerator scheme introduces so-called crosstalk, i.e. detection of losses originating in one beam line by the monitors protecting the other. Moreover, electrons emitted from the inner surface of RF cavities and boosted by the high RF gradients may produce signals in neighbouring BLMs, limiting their ability to detect real beam losses. This contribution presents the results of dedicated experiments performed in the CLIC Test Facility to qu...

  4. [Research on stormwater runoff quality of mountain city by source area monitoring].

    Science.gov (United States)

    Li, Li-Qing; Shan, Bao-Qing; Zhao, Jian-Wei; Guo, Shu-Gang; Gao, Yong

    2012-10-01

    Stormwater runoff samples were collected from 10 source areas in Mountain City, Chongqing, during five rain events in an attempt to investigate the characteristics of runoff quality and influencing factors. The outcomes are expected to offer practical guidance of sources control of urban runoff pollution. The results indicated that the stormwater runoff of Mountain City presented a strong first flush for almost all events and constituents. The runoff quality indices were also influenced by the rainfall intensity. The concentration of TSS, COD, TN and TP decreased as the rainfall intensity increased. The concentrations of COD and TP in stormwater runoff were highly correlated with TSS concentrations. Suspended solid matter were not only the main pollutant of stormwater runoff but also served as the vehicle for transport of organic matter and phosphorus. Organic matter and phosphorus in stormwatrer runoff were mainly bound to particles, whereas nitrogen was predominantly dissolved, with ammonia and nitrate. A significant difference of stormwater runoff quality was observed among the ten monitored source areas. The highest magnitude of urban stormwater runoff pollution was expected in the commercial area and the first trunk road, followed by the minor road, residential area, parking lot and roof. Urban surface function, traffic volume, population density, and street sweeping practice are the main factors determining spatial differentiation of urban surface runoff quality. Commercial area, the first trunk road and residential area with high population density are the critical sources areas of urban stormwater runoff pollution.

  5. Preparedness for response to the challenges from orphan sources: nationwide environmental radiation mapping with state of the art monitoring systems

    International Nuclear Information System (INIS)

    Saindane, Shashank S.; Pradeepkumar, K.S.; Suri, M.M.K.; Sharma, D.N.

    2008-01-01

    Based on the various international reports on orphan sources, the potential for radiological emergencies in public domain is recognized as a cause of concern. To detect the presence of any such orphan sources and to strengthen the preparedness for response to any radiological emergencies in public domain, a nationwide radiation mapping programme was initiated in India. Various radiation monitoring systems, few of them integrated with Global Positioning System (GPS) installed in mobile monitoring vans were used for this purpose. This monitoring also helped in generating the base line dose rate data of the cities and also in demonstrating the methodology of environmental monitoring for locating the presence of orphan sources, if any. During the detailed monitoring of various cities of the country, different systems such as GSM based Radiation Monitoring System (GRaMS), Compact Radiation Monitoring system, Portable Mobile Gamma Spectrometry System, Gamma Tracer System etc. installed in a vehicle were made to continuously acquire the data at a varying rate from 10 sec to 1 minute acquisition time. These systems can measure dose rate in the range of 0.01 - 100 μGy h -1 and can detect 7.4 MBq (200 μCi) of 60 Co and 25 MBq (675 μCi) of 137 Cs from a distance of 5 metre. Average dose rate recorded during these environmental monitoring was 81 ± 07 nGy h -1 with a maximum of 210 ± 11 nGyh -1 at Bangalore (attributed to the presence of K-40). The digital topographic map and the data acquired from the radiation mapping are used to generate terrestrial radiation map. This radiation profile stored in the database can be used as reference while carrying out the impact assessment following any nuclear / radiological emergencies. These systems also help to tag the radiation levels along with positional coordinates online onto the GIS map of the area. GRaMS also demonstrated its capability for online transmission of the data to the centralized data acquisition Base Station

  6. Development of an asymmetric multiple-position neutron source (AMPNS) method to monitor the criticality of a degraded reactor core

    International Nuclear Information System (INIS)

    Kim, S.S.; Levine, S.H.

    1985-01-01

    An analytical/experimental method has been developed to monitor the subcritical reactivity and unfold the k/sub infinity/ distribution of a degraded reactor core. The method uses several fixed neutron detectors and a Cf-252 neutron source placed sequentially in multiple positions in the core. Therefore, it is called the Asymmetric Multiple Position Neutron Source (AMPNS) method. The AMPNS method employs nucleonic codes to analyze the neutron multiplication of a Cf-252 neutron source. An optimization program, GPM, is utilized to unfold the k/sub infinity/ distribution of the degraded core, in which the desired performance measure minimizes the error between the calculated and the measured count rates of the degraded reactor core. The analytical/experimental approach is validated by performing experiments using the Penn State Breazeale TRIGA Reactor (PSBR). A significant result of this study is that it provides a method to monitor the criticality of a damaged core during the recovery period

  7. Smart x-ray beam position monitor system using artificial intelligence methods for the advanced photon source insertion-device beamlines

    International Nuclear Information System (INIS)

    Shu, D.; Ding, H.; Barraza, J.; Kuzay, T.M.; Haeffner, D.; Ramanathan, M.

    1997-09-01

    At the Advanced Photon Source (APS), each insertion device (ID) beamline front-end has two XBPMs to monitor the X-ray beam position for both that vertical and horizontal directions. Performance challenges for a conventional photoemission type X-ray beam position monitor (XBPM) during operations are contamination of the signal from the neighboring bending magnet sources and the sensitivity of the XBPM to the insertion device (ID) gap variations. Problems are exacerbated because users change the ID gap during their operations, and hence the percentage level of the contamination in the front end XBPM signals varies. A smart XBPM system with a high speed digital signal processor has been built at the Advanced Photon Source for the ID beamline front ends. The new version of the software, which uses an artificial intelligence method, provides a self learning and self-calibration capability to the smart XBPM system. The structure of and recent test results with the system are presented in this paper

  8. Stable carbon isotopes to monitor the CO2 source mix in the urban environment

    Science.gov (United States)

    Vogel, F. R.; Wu, L.; Ramonet, M.; Broquet, G.; Worthy, D. E. J.

    2014-12-01

    Urban areas are said to be responsible for approximately 71% of fossil fuel CO2 emissions while comprising only two percent of the land area [IEA, 2008]. This limited spatial expansion could facility a monitoring of anthropogenic GHGs from atmospheric observations. As major sources of emissions, cities also have a huge potential to drive emissions reductions. To effectively manage emissions, cities must however, first establish techniques to validate their reported emission statistics. A pilot study which includes continues 13CO2 data from calibrated cavity ring-down spectrometers [Vogel et al. 2013] of two "sister sites" in the vicinity of Toronto, Canada is contrasted to recent observations of 13CO2 observations in Paris during significant pollution events. Using Miller-Tans plots [Miller and Tans, 2003] for our multi-season observations reveals significant changes of the source signatures of night time CO2 emissions which reflect the importance of natural gas burning in Megacities (up to 80% of fossil fuel sources) and show-case the potential of future isotope studies to determine source sectors. Especially the winter data this approach seems suitable to determine the source contribution of different fuel types (natural gas, liquid fuels and coal) which can inform the interpretation of other Greenhouse Gases and air pollution levels.

  9. Study of the flying ability of Rhynchophorus ferrugineus (Coleoptera: Dryophthoridae) adults using a computer-monitored flight mill.

    Science.gov (United States)

    Ávalos, J A; Martí-Campoy, A; Soto, A

    2014-08-01

    The red palm weevil, Rhynchophorus ferrugineus (Olivier) (Coleoptera: Dryophthoridae), native to tropical Asian regions, has become a serious threat to palm trees all over the world. Knowledge of its flight potential is vital to improving the preventive and curative measures currently used to manage this pest. As R. ferrugineus is a quarantine pest, it is difficult to study its flight potential in the field. A computer-monitored flight mill was adapted to analyse the flying ability of R. ferrugineus through the study of different flight parameters (number of flights, total distance flown, longest single flight, flight duration, and average and maximum speed) and the influence of the weevil's sex, age, and body size on these flight parameters. Despite significant differences in the adult body size (body weight and length) of males and females, the sex of R. ferrugineus adults did not have an influence on their flight potential. Neither adult body size nor age was found to affect the weevil's flying abilities, although there was a significantly higher percentage of individuals flying that were 8-23 days old than 1-7 days old. Compared to the longest single flight, 54% of the insects were classified as short-distance flyers (covering 5000 m), respectively. The results are compared with similar studies on different insect species under laboratory and field conditions.

  10. Predictability and context determine differences in conflict monitoring between adolescence and adulthood.

    Science.gov (United States)

    Chmielewski, Witold X; Roessner, Veit; Beste, Christian

    2015-10-01

    The ability to link contextual information to actions is an important aspect of conflict monitoring and response selection. These mechanisms depend on medial prefrontal networks. Although these areas undergo a protracted development from adolescence to adulthood, it has remained elusive how the influence of contextual information on conflict monitoring is modulated between adolescence and adulthood. Using event-related potentials (ERPs) and source localization techniques we show that the ability to link contextual information to actions is altered and that the predictability of upcoming events is an important factor to consider in this context. In adolescents, conflict monitoring functions are not as much modulated by predictability factors as in adults. It seems that adults exhibit a stronger anticipation of upcoming events than adolescents. This results in disadvantages for adults when the upcoming context is not predictable. In adolescents, problems to predict upcoming events therefore turn out to be beneficial. Two cognitive-neurophysiological factors are important for this: The first factor is related to altered conflict monitoring functions associated with modulations of neural activity in the medial frontal cortex. The second factor is related to altered perceptual processing of target stimuli associated with modulations of neural activity in parieto-occipital areas. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Digital intelligence sources transporter

    International Nuclear Information System (INIS)

    Zhang Zhen; Wang Renbo

    2011-01-01

    It presents from the collection of particle-ray counting, infrared data communication, real-time monitoring and alarming, GPRS and other issues start to realize the digital management of radioactive sources, complete the real-time monitoring of all aspects, include the storing of radioactive sources, transporting and using, framing intelligent radioactive sources transporter, as a result, achieving reliable security supervision of radioactive sources. (authors)

  12. Variability in GPS sources

    NARCIS (Netherlands)

    Jauncey, DL; King, EA; Bignall, HE; Lovell, JEJ; Kedziora-Chudczer, L; Tzioumis, AK; Tingay, SJ; Macquart, JP; McCulloch, PM

    2003-01-01

    Flux density monitoring data at 2.3 and 8.4 GHz is presented for a sample of 33 southern hemisphere GPS sources, drawn from the 2.7 GHz Parkes survey. This monitoring data, together with VLBI monitoring data, shows that a small fraction of these sources, similar to10%, vary. Their variability falls

  13. Triple GEM gas detectors as real time fast neutron beam monitors for spallation neutron sources

    International Nuclear Information System (INIS)

    Murtas, F; Claps, G; Croci, G; Tardocchi, M; Pietropaolo, A; Cippo, E Perelli; Rebai, M; Gorini, G; Frost, C D; Raspino, D; Rhodes, N J; Schooneveld, E M

    2012-01-01

    A fast neutron beam monitor based on a triple Gas Electron Multiplier (GEM) detector was developed and tested for the ISIS spallation neutron source in U.K. The test on beam was performed at the VESUVIO beam line operating at ISIS. The 2D fast neutron beam footprint was recorded in real time with a spatial resolution of a few millimeters thanks to the patterned detector readout.

  14. Change Detection for Remote Monitoring of Underground Nuclear Testing: Comparison with Seismic and Associated Explosion Source Phenomenological Data

    DEFF Research Database (Denmark)

    Canty, M.; Jahnke, G.; Nielsen, Allan Aasbjerg

    2005-01-01

    The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection of anthrop......The analysis of open-source satellite imagery is in process of establishing itself as an important tool for monitoring nuclear activities throughout the world which are relevant to disarmament treaties, like e. g. the Comprehensive Nuclear-Test-Ban Treaty (CTBT). However, the detection...... of conventional multispectral satellite platforms with moderate ground resolution (Landsat TM, ASTER) to detect changes over wide areas.We chose the Nevada Test Site (NTS), USA, for a case study because of the large amount of available ground truth information. The analysis is based on the multivariate alteration...

  15. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  16. Continuous Tracking of RFID Tagged Radioactive Sources

    International Nuclear Information System (INIS)

    Broide, A.; Marcus, E.; Gabay, Y.; Miron, E.; Seif, R.; Wengrowicz, U.; Kadmon, Y.; Tirosh, D.

    2008-01-01

    The prevention of radiation hazards due to radioisotopes is one of the concerns of the Atomic Energy Agency (IAEA). In a series of international conferences held in the last five years) this issue was discussed thoroughly. One of the conclusions was that strict management of radioactive sources is essential. The management of radioactive sources would help to prevent transference of radioactive materials to unauthorized personal. For this purpose, states should make a concerted effort to follow the principles of the Code of Conduct on the Security of Radioactive Sources(2). In this context, the identification of roles and responsibilities of governments, licensees and international organizations is vital(3). The referred activities are primarily related to control over radioactive sources and enhance the tracking ability of radiation sources . In this paper, a proposed Radioactive Sources Tracking System is presented. This system facilitates real time monitoring capability of fixed and mobile radiation sources. The system provides the location of the source and indication whether the source is inside or outside the shielding container. The information about the sources location and condition can be used to coordinate a fast response in case of any attempt to steal or tamper with a source. These goals are achieved by using GPS (Global Positioning System), RFID (Radio Frequency Identification) and control and management software

  17. Design and performance of the beam loss monitor system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Patterson, D.

    1994-01-01

    The design of the beam loss monitor system for the Argonne National Laboratory Advanced Photon Source is based on using a number of air dielectric coaxial cables as long ionization chambers. The coaxial cables are multiplexed into a high sensitivity DC current-to-voltage converter, which provides an output proportional to the average loss rate over the length of the multiplexed cable. Losses of sufficient amplitude generate measurable voltage pulses on the coaxial cable at a location near the loss point. Multiplexed pulse timing circuits determine the location of the losses by measuring the time at which these voltage pulses arrive at the beginning of the coaxial cable. The loss monitor system has been tested on the SPEAR accelerator at SSRL and was demonstrated to be as sensitive as the DCCT. Preliminary performance data from the APS injector show that the sensitivities of the current-to-voltage, converter circuit are about ten picoamperes of loss monitor signal per picocoulomb per second beam loss rate. The corresponding pulse sensitivity is about 28 μV pulse amplitude in the coaxial cable per picocoulomb of loss. Both these sensitivities are at 300-MeV beam energies. The loss monitor has proven useful in initial commissioning of the injector. Further data will be available as accelerator construction and commissioning continue

  18. Passive monitoring for near surface void detection using traffic as a seismic source

    Science.gov (United States)

    Zhao, Y.; Kuzma, H. A.; Rector, J.; Nazari, S.

    2009-12-01

    In this poster we present preliminary results based on our several field experiments in which we study seismic detection of voids using a passive array of surface geophones. The source of seismic excitation is vehicle traffic on nearby roads, which we model as a continuous line source of seismic energy. Our passive seismic technique is based on cross-correlation of surface wave fields and studying the resulting power spectra, looking for "shadows" caused by the scattering effect of a void. High frequency noise masks this effect in the time domain, so it is difficult to see on conventional traces. Our technique does not rely on phase distortions caused by small voids because they are generally too tiny to measure. Unlike traditional impulsive seismic sources which generate highly coherent broadband signals, perfect for resolving phase but too weak for resolving amplitude, vehicle traffic affords a high power signal a frequency range which is optimal for finding shallow structures. Our technique results in clear detections of an abandoned railroad tunnel and a septic tank. The ultimate goal of this project is to develop a technology for the simultaneous imaging of shallow underground structures and traffic monitoring near these structures.

  19. Comparing different types of source memory attributes in dementia of Alzheimer's type.

    Science.gov (United States)

    Mammarella, Nicola; Fairfield, Beth; Di Domenico, Alberto

    2012-04-01

    Source monitoring (SM) refers to our ability to discriminate between memories from different sources. Twenty healthy high-cognitive functioning older adults, 20 healthy low-cognitive functioning older adults, and 20 older adults with dementia of Alzheimer's type (DAT) were asked to perform a series of SM tasks that varied in terms of the to-be-remembered source attribute (perceptual, spatial, temporal, semantic, social, and affective details). Results indicated that older DAT adults had greater difficulty in SM compared to the healthy control groups, especially with spatial and semantic details. Data are discussed in terms of the SM framework and suggest that poor memory for some types of source information may be considered as an important indicator of clinical memory function when assessing for the presence and severity of dementia.

  20. Age-related differences in multiple task monitoring.

    Science.gov (United States)

    Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo

    2014-01-01

    Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age.

  1. Age-related differences in multiple task monitoring.

    Directory of Open Access Journals (Sweden)

    Ivo Todorov

    Full Text Available Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age.

  2. Design considerations for neutron activation and neutron source strength monitors for ITER

    International Nuclear Information System (INIS)

    Barnes, C.W.; Jassby, D.L.; LeMunyan, G.; Roquemore, A.L.

    1997-01-01

    The International Thermonuclear Experimental Reactor will require highly accurate measurements of fusion power production in time, space, and energy. Spectrometers in the neutron camera could do it all, but experience has taught us that multiple methods with redundancy and complementary uncertainties are needed. Previously, conceptual designs have been presented for time-integrated neutron activation and time-dependent neutron source strength monitors, both of which will be important parts of the integrated suite of neutron diagnostics for this purpose. The primary goals of the neutron activation system are: to maintain a robust relative measure of fusion energy production with stability and wide dynamic range; to enable an accurate absolute calibration of fusion power using neutronic techniques as successfully demonstrated on JET and TFTR; and to provide a flexible system for materials testing. The greatest difficulty is that the irradiation locations need to be close to plasma with a wide field of view. The routing of the pneumatic system is difficult because of minimum radius of curvature requirements and because of the careful need for containment of the tritium and activated air. The neutron source strength system needs to provide real-time source strength vs. time with ∼1 ms resolution and wide dynamic range in a robust and reliable manner with the capability to be absolutely calibrated by in-situ neutron sources as done on TFTR, JT-60U, and JET. In this paper a more detailed look at the expected neutron flux field around ITER is folded into a more complete design of the fission chamber system

  3. Laser Gas-Analyser for Monitoring a Source of Gas Pollution

    Directory of Open Access Journals (Sweden)

    V. A. Gorodnichev

    2015-01-01

    Full Text Available Currently, the problem of growing air pollution of the Earth is of relevance. Many countries have taken measures to protect the environment in order to limit the negative anthropogenic impacts.In such a situation an objective information on the actual content of pollutants in the atmosphere is of importance. For operational inspection of the pollutant concentrations and for monitoring pollution sources, it is necessary to create high-speed high-sensitivity gas analysers.Laser meters are the most effective to provide operational remote and local inspection of gas pollution of the Earth atmosphere.Laser meter for routine gas analysis should conduct operational analysis of the gas mixture (air. For this a development of appropriate information support is required.Such information support should include a database with absorption coefficients of pollutants (specific to potential sources of pollution at possible measuring wavelengths (holding data for a particular emitter of the laser meter and an efficient algorithms to search the measuring wavelengths and conduct a quantitative analysis of gas mixtures.Currently, the issues, important for practice and related to the development of information support for the laser gas analyzer to conduct important for practice routine measurements remain unclear.In this paper we develop an algorithm to provide an operational search of the measuring wavelengths of laser gas analyser and an algorithm to recover quantitively the gaseous component concentrations of controlled gas mixture from the laser multi-spectral measurements that take into account a priori information about the source-controlled gas pollution and do not require a large amount of computation. The method of mathematical simulation shows the effectiveness of the algorithms described both for seach of measuring wavelengths and for quantitative analysis of gas releases.

  4. Quantitative Analysis of VIIRS DNB Nightlight Point Source for Light Power Estimation and Stability Monitoring

    Directory of Open Access Journals (Sweden)

    Changyong Cao

    2014-12-01

    Full Text Available The high sensitivity and advanced onboard calibration on the Visible Infrared Imaging Radiometer Suite (VIIRS Day/Night Band (DNB enables accurate measurements of low light radiances which leads to enhanced quantitative applications at night. The finer spatial resolution of DNB also allows users to examine social economic activities at urban scales. Given the growing interest in the use of the DNB data, there is a pressing need for better understanding of the calibration stability and absolute accuracy of the DNB at low radiances. The low light calibration accuracy was previously estimated at a moderate 15% using extended sources while the long-term stability has yet to be characterized. There are also several science related questions to be answered, for example, how the Earth’s atmosphere and surface variability contribute to the stability of the DNB measured radiances; how to separate them from instrument calibration stability; whether or not SI (International System of Units traceable active light sources can be designed and installed at selected sites to monitor the calibration stability, radiometric and geolocation accuracy, and point spread functions of the DNB; furthermore, whether or not such active light sources can be used for detecting environmental changes, such as aerosols. This paper explores the quantitative analysis of nightlight point sources, such as those from fishing vessels, bridges, and cities, using fundamental radiometry and radiative transfer, which would be useful for a number of applications including search and rescue in severe weather events, as well as calibration/validation of the DNB. Time series of the bridge light data are used to assess the stability of the light measurements and the calibration of VIIRS DNB. It was found that the light radiant power computed from the VIIRS DNB data matched relatively well with independent assessments based on the in situ light installations, although estimates have to be

  5. Application of online chemistry monitoring programs and technology

    International Nuclear Information System (INIS)

    Perkins, D.; Choi, S.; Haas, C.

    2010-01-01

    To fully understand the impact of chemistry changes, several plant parameters must be considered and reviewed with actual chemistry analyses and compared to plant operating parameters. In some cases, this requires the ability to rapidly correlate plant operational data with laboratory and chemistry data. An effective online monitoring system should be able to: Integrate and extract online data from the plant laboratory and operating information from various plant data sources continuously; Interrogate and extract laboratory data from manually entered data on predefined frequencies; Interact with multiple laboratories in multiple locations; Evaluate data against plant limits (calculated or static) and provide personnel with action level or notification of plant exceeding limits; and, Provide the ability to evaluate against a standard and site specific set of calculations. The nuclear power industry continues to refine and apply new technologies in an effort to notify operators of changes in chemical conditions, calculate complex high temperature results, and monitor system performance. EPRI developed software specifically focused on plant chemistry program optimization using power operation and shutdown data applied with plant equipment. This software evolved into the family of software referred to as EPRI ChemWorks™ applications. As technology changed and improved, the application of online monitoring was essential for plant personnel working offsite. These changes in technology prompted EPRI to the development of SMART ChemWorks™ using the EPRI ChemWorks™ plant chemistry simulator and MULTEQ applications as the backbone for these simulations and calculations. SMART ChemWorks™ is an online monitoring system that queries plant databases and continuously monitors plant and chemistry parameters. The system uses a real-time intelligence engine to perform virtual sensing, identify normal and off-normal conditions and compare in-line instrument output to grab

  6. Subcriticality monitoring method for reactor

    International Nuclear Information System (INIS)

    Ueda, Makoto.

    1991-01-01

    The present invention accurately monitors the reactor subcriticality and ensures the critical safety, irrespective of the presence or absence of artificial neutron sources. That is, when the subcriticality is monitored upon reactivity changing operation which causes reactivity change to the reactor during shutdown, neutron monitors are disposed at a plurality of monitoring positions. Then, neutron counting ratio before and after conducting the reactivity changing operation is determined. The subcriticality of the reactor is monitored by the ratio and the state of scattering of the ratio of neutron counting rate between each of the neutron monitors. With such procedures, signals of the neutron monitors are used, the characteristic that the change of the signals depend on the change of the neutron multiplication of the reactor core can be utilized whether artificial neutron sources (external neutron sources) are disposed or not. Accordingly, the subcriticality can be monitored more reliably. (I.S.)

  7. Ultra-stable implanted 83Rb/83mKr electron sources for the energy scale monitoring in the KATRIN experiment

    CERN Document Server

    Zboril, M.; Beck, M.; Bonn, J.; Dragoun, O.; Jakubek, J.; Johnston, K.; Kovalik, A.; Otten, E.W.; Schlösser, K.; Slezak, M.; Spalek, A.; Thümmler, T.; Venos, D.; Zemlicka, J.; Weinheimer, C.

    2013-01-01

    The KATRIN experiment aims at the direct model-independent determination of the average electron neutrino mass via the measurement of the endpoint region of the tritium beta decay spectrum. The electron spectrometer of the MAC-E filter type is used, requiring very high stability of the electric filtering potential. This work proves the feasibility of implanted 83Rb/83mKr calibration electron sources which will be utilised in the additional monitor spectrometer sharing the high voltage with the main spectrometer of KATRIN. The source employs conversion electrons of 83mKr which is continuously generated by 83Rb. The K-32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7 eV) is shown to fulfill the KATRIN requirement of the relative energy stability of +/-1.6 ppm/month. The sources will serve as a standard tool for continuous monitoring of KATRIN's energy scale stability with sub-ppm precision. They may also be used in other applications where the precise conversion lines can be separated fr...

  8. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  9. Integration of acoustic emission systems within Integri-TechTM analysis system for structural health monitoring of pressurised engineering plant

    International Nuclear Information System (INIS)

    Ghouri, A A; Galbraith, Walter; Pierce, S Gareth; Gachagan, Anthony; Rafferty, Steven; Pickwell, Andy

    2015-01-01

    The aim of this Acoustic Emission (AE) based Structural Health Monitoring project is to enable accurate location of AE sources in pressurised engineering plant and to use AE source location data to establish defect locations for use within Integri-Tech TM ; a finite element based analysis, monitoring and fitness for service assessment system. Integri-Tech TM is a windows based system which carries out combined analysis and assessment providing fatigue life and remnant life calculations and inspection priorities presenting the results in an accessible web portal format. The software uses finite element stress models created in the companion software Model Wizard. The AE monitoring system that has been developed can be used with an array of up to four AE broad band sensor channels with associated signal processing. Using a flexible approach in MATLAB, the authors have developed algorithms which were used for analysing the received AE signals to extract information about the nature and location of the source. The ability to carry out source location and possibly perform real time monitoring (detecting cracking as it occurs) is attractive feature of the AE system developed for this project. The time of arrival (TOA) data was used by Integri-Tech TM software to calculate source location using its own built-in algorithm, and this was verified independently using a MATLAB approach. (paper)

  10. Detector module for gas monitor

    International Nuclear Information System (INIS)

    1980-01-01

    The invention relates to radioactive source detector module for use in a gas monitor. It is adapted to contain the source and other detector components to allow sealed coupling of those components with other portions of the gas monitor. It is particularly concerned with the use of radioactive materials used as electron sources in gas monitors. The module is used to detect changes in electron flow caused by partial absorption of the electron capture gas flowing between two electrodes. The assembly includes a gas flow source, a gas receiver and an electronic assembly for receiving a signal from the detector. The radioactive source and electrodes are housed so that they are connected to the gas flow source so as to prevent accidental or undesired disconnection. It is designed so that the detector module may be removed or replaced into the gas monitor assemblies by untrained personnel so as to prevent exposure to the radioactive material. Full details are given. (U.K.)

  11. Monitoring commercial conventional facilities control with the APS control system: The Metasys-to-EPICS interface

    International Nuclear Information System (INIS)

    Nawrocki, G.J.; Seaver, C.L.; Kowalkowski, J.B.

    1995-01-01

    As controls needs at the Advanced Photon Source matured from an installation phase to an operational phase, the need to monitor the existing conventional facilities control system with the EPICS-based accelerator control system was realized. This existing conventional facilities control network is based on a proprietary system from Johnson Controls called Metasys. Initially read-only monitoring of the Metasys parameters will be provided; however, the ability for possible future expansion to full control is available. This paper describes a method of using commercially available hardware and existing EPICS software as a bridge between the Metasys and EPICS control systems

  12. Monitoring of PM10 and PM2.5 around primary particulate anthropogenic emission sources

    Science.gov (United States)

    Querol, Xavier; Alastuey, Andrés; Rodriguez, Sergio; Plana, Felicià; Mantilla, Enrique; Ruiz, Carmen R.

    Investigations on the monitoring of ambient air levels of atmospheric particulates were developed around a large source of primary anthropogenic particulate emissions: the industrial ceramic area in the province of Castelló (Eastern Spain). Although these primary particulate emissions have a coarse grain-size distribution, the atmospheric transport dominated by the breeze circulation accounts for a grain-size segregation, which results in ambient air particles occurring mainly in the 2.5-10 μm range. The chemical composition of the ceramic particulate emissions is very similar to the crustal end-member but the use of high Al, Ti and Fe as tracer elements as well as a peculiar grain-size distribution in the insoluble major phases allow us to identify the ceramic input in the bulk particulate matter. PM2.5 instead of PM10 monitoring may avoid the interference of crustal particles without a major reduction in the secondary anthropogenic load, with the exception of nitrate. However, a methodology based in PM2.5 measurement alone is not adequate for monitoring the impact of primary particulate emissions (such as ceramic emissions) on air quality, since the major ambient air particles derived from these emissions are mainly in the range of 2.5-10 μm. Consequently, in areas characterised by major secondary particulate emissions, PM2.5 monitoring should detect anthropogenic particulate pollutants without crustal particulate interference, whereas PM10 measurements should be used in areas with major primary anthropogenic particulate emissions.

  13. Farm Management Support on Cloud Computing Platform: A System for Cropland Monitoring Using Multi-Source Remotely Sensed Data

    Science.gov (United States)

    Coburn, C. A.; Qin, Y.; Zhang, J.; Staenz, K.

    2015-12-01

    Food security is one of the most pressing issues facing humankind. Recent estimates predict that over one billion people don't have enough food to meet their basic nutritional needs. The ability of remote sensing tools to monitor and model crop production and predict crop yield is essential for providing governments and farmers with vital information to ensure food security. Google Earth Engine (GEE) is a cloud computing platform, which integrates storage and processing algorithms for massive remotely sensed imagery and vector data sets. By providing the capabilities of storing and analyzing the data sets, it provides an ideal platform for the development of advanced analytic tools for extracting key variables used in regional and national food security systems. With the high performance computing and storing capabilities of GEE, a cloud-computing based system for near real-time crop land monitoring was developed using multi-source remotely sensed data over large areas. The system is able to process and visualize the MODIS time series NDVI profile in conjunction with Landsat 8 image segmentation for crop monitoring. With multi-temporal Landsat 8 imagery, the crop fields are extracted using the image segmentation algorithm developed by Baatz et al.[1]. The MODIS time series NDVI data are modeled by TIMESAT [2], a software package developed for analyzing time series of satellite data. The seasonality of MODIS time series data, for example, the start date of the growing season, length of growing season, and NDVI peak at a field-level are obtained for evaluating the crop-growth conditions. The system fuses MODIS time series NDVI data and Landsat 8 imagery to provide information of near real-time crop-growth conditions through the visualization of MODIS NDVI time series and comparison of multi-year NDVI profiles. Stakeholders, i.e., farmers and government officers, are able to obtain crop-growth information at crop-field level online. This unique utilization of GEE in

  14. Preliminary design of the beam loss monitor system for the Advanced Photon Source

    International Nuclear Information System (INIS)

    Patterson, D.R.

    1992-01-01

    The preliminary design of the beam loss monitor for the ANL Advanced Photon Source is based on the use of an air dielectric coaxial cable as a long ionization chamber. Each coaxial cable section uses a high sensitivity DC current-to-voltage converter with both linear and integrating ranges. Pulse timing circuits determine the positions of individual losses by measuring the time at which the resulting voltage pulses arrive at the beginning of the coaxial ionization chamber. A possible timing ambiguity can be removed by correlating the particle bunch timing with the resulting voltage pulse timing. Measurements have shown that pulse rise times less than 15 nanoseconds can be obtained, so that determining loss locations to better than 7 feet may be possible. Best performance may be obtained when 500 VDC is applied to a 50-ohm, 7/8-inch air dielectric coaxial cable filled with approximately 8 psig of a 95% argon, 5% carbon dioxide gas mixture. Cable lengths will be between 100 and 300 feet long, depending on the part of the accelerator being monitored

  15. Temporal dynamics of conflict monitoring and the effects of one or two conflict sources on error-(related) negativity.

    Science.gov (United States)

    Armbrecht, Anne-Simone; Wöhrmann, Anne; Gibbons, Henning; Stahl, Jutta

    2010-09-01

    The present electrophysiological study investigated the temporal development of response conflict and the effects of diverging conflict sources on error(-related) negativity (Ne). Eighteen participants performed a combined stop-signal flanker task, which was comprised of two different conflict sources: a left-right and a go-stop response conflict. It is assumed that the Ne reflects the activity of a conflict monitoring system and thus increases according to (i) the number of conflict sources and (ii) the temporal development of the conflict activity. No increase of the Ne amplitude after double errors (comprising two conflict sources) as compared to hand- and stop-errors (comprising one conflict source) was found, whereas a higher Ne amplitude was observed after a delayed stop-signal onset. The results suggest that the Ne is not sensitive to an increase in the number of conflict sources, but to the temporal dynamics of a go-stop response conflict. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  16. Evaluation the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha

    2011-01-01

    In vivo monitoring techniques consist of identification and quantification of radionuclides present in the whole body and specific organs and tissues. In Vivo monitoring requires the use of detedors which are sensitive to the radiation emitted by radionuclides present in the monitored individual. The results obtained in measurements may present small uncertainties which are within pre-set limits in monitoring programs for occupationally exposed individuais. However, any device used to determine physical quantities present uncertainties in the measured values. The total uncertainty of a measurement result is estimated from the propagation of the uncertainties associated to each parameter of the calculation. This study aims to evaluate the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid, in comparison to the suggested in the General Guide for Estimating Effective Doses from Monitoring Data (Project IDEAS/European Community). The reference values used were the ones for high-energy photons (>100 keV). The measurement uncertainties were divided into two categories: type A and type B. The component of type A represents the statistical fluctuation in the counting of the standard source. Regarding type B, the following variations were presented: detector positioning over the phantom; variation of background radiation; thickness of the overlay tissue over the monitored organ, distribution of the activity in the organ. Besides the parameters suggested by the IDEAS Guide, it has also been evaluated the fluctuation of the counting due to the phantom repositioning, which represents the reproducibility of the measurement geometry. Measurements were performed at the Whole Body Counter Unit of IRD using a scintillation detector Nal (Tl) 3 x3 and a neck-thyroid phantom developed at LABMIVIRD. Scattering factors were calculated and compared in different counting geometries. The results of this study show that the

  17. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    International Nuclear Information System (INIS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-01-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring. (c)

  18. The national response for preventing healthcare-associated infections: data and monitoring.

    Science.gov (United States)

    Kahn, Katherine L; Weinberg, Daniel A; Leuschner, Kristin J; Gall, Elizabeth M; Siegel, Sari; Mendel, Peter

    2014-02-01

    Historically, the ability to accurately track healthcare-associated infections (HAIs) was hindered due to a lack of coordination among data sources and shortcomings in individual data sources. This paper presents the results of the evaluation of the HAI data and the monitoring component of the Action Plan, focusing on context (goals), inputs, and processes. We used the Content-Input-Process-Product framework, together with the HAI prevention system framework, to describe the transformative processes associated with data and monitoring efforts. Six HAI priority conditions in the 2009 Action Plan created a focus for the selection of goals and activities. Key Action Plan decisions included a phased-in data and monitoring approach, commitment to linking the selection of priority HAIs to highly visible national 5-year prevention targets, and the development of a comprehensive HAI database inventory. Remaining challenges relate to data validation, resources, and the opportunity to integrate electronic health and laboratory records with other provider data systems. The Action Plan's data and monitoring program has developed a sound infrastructure that builds upon technological advances and embodies a firm commitment to prioritization, coordination and alignment, accountability and incentives, stakeholder engagement, and an awareness of the need for predictable resources. With time, and adequate resources, it is likely that the investment in data-related infrastructure during the Action Plan's initial years will reap great rewards.

  19. New Advanced Source Identification Algorithm (ASIA-NEW) for radiation monitors with plastic detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stavrov, Andrei; Yamamoto, Eugene [Rapiscan Systems, Inc., 14000 Mead Street, Longmont, CO, 80504 (United States)

    2015-07-01

    Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the authors and based on some experimental test results. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co-57, Ba-133 and other). New variant of ASIA is based on physical principles and does not require a lot of special tests to attain statistical data for its parameters. That is why this system can be easily installed into any RPM with plastic detectors. This algorithm was tested for 1,395 passages of different transports (cars, trucks and trailers) without radioactive sources. It also was tested for 4,015 passages of these transports with radioactive sources of different activity (Co-57, Ba-133, Cs-137, Co-60, Ra-226, Th-232) and these sources masked by NORM (K-40) as well

  20. Microcontroller based motion control interface unit for double slit type beam emittance monitor for H- ion source

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Jain, Rahul; Karnewar, A.K.; Sonawane, B.B.; Maurya, N.K.; Puntambekar, T.A.

    2015-01-01

    The Indian Spallation Neutron Source (ISNS), proposed to be developed at RRCAT, will use a 1 GeV H - linac and an accumulator ring to produce high flux of pulsed neutrons via spallation process. The development activity of front end of 1H - linac for ISNS is under progress at RRCAT, for which a pulsed H - ion source of 50 keV energy, 30 mA current with pulse width of 500 μs has been developed at RRCAT. In this paper, we present the design and development of a microcontroller based motion control interface unit for double slit type beam emittance monitor for the H - ion source. This is an interceptive type of beam diagnostic device, which is used for the quantitative measurement of transverse emittance and beam intensity profile

  1. Python Open source Waveform ExtractoR (POWER): an open source, Python package to monitor and post-process numerical relativity simulations

    Science.gov (United States)

    Johnson, Daniel; Huerta, E. A.; Haas, Roland

    2018-01-01

    Numerical simulations of Einstein’s field equations provide unique insights into the physics of compact objects moving at relativistic speeds, and which are driven by strong gravitational interactions. Numerical relativity has played a key role to firmly establish gravitational wave astrophysics as a new field of research, and it is now paving the way to establish whether gravitational wave radiation emitted from compact binary mergers is accompanied by electromagnetic and astro-particle counterparts. As numerical relativity continues to blend in with routine gravitational wave data analyses to validate the discovery of gravitational wave events, it is essential to develop open source tools to streamline these studies. Motivated by our own experience as users and developers of the open source, community software, the Einstein Toolkit, we present an open source, Python package that is ideally suited to monitor and post-process the data products of numerical relativity simulations, and compute the gravitational wave strain at future null infinity in high performance environments. We showcase the application of this new package to post-process a large numerical relativity catalog and extract higher-order waveform modes from numerical relativity simulations of eccentric binary black hole mergers and neutron star mergers. This new software fills a critical void in the arsenal of tools provided by the Einstein Toolkit consortium to the numerical relativity community.

  2. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  3. Deep Controlled Source Electro-Magnetic Sensing: A Cost Effective, Long-Term Tool for Sequestration Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    LaBrecque, Douglas [Multi-Phase Technologies, LLC, Sparks, NV (United States); Brigham, Russell D. [Multi-Phase Technologies, LLC, Sparks, NV (United States); Schmidt-Hattenburger, Conny [GFZ German Research Centre for Geoscience, Potsdam (Germany); Um, Evan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Petrov, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Daley, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    The proposed system was designed to operate as a permanent, autonomous monitoring and data collection system that can provide much higher temporal data density than can be achieved economically with 3-Dimensional (3D) seismic surveys. It can operate over broad areas for long periods of time providing full 3D data sets on a monthly basis at a very low cost. By borrowing techniques commonly used in marine CSEM, structural information from background seismic surveys can be incorporated into the CSEM modeling to provide high resolution models of CO2 progression within reservoirs. The system uses borehole-based vertical-electric-dipole sources placed at reservoir depths in the formation. The electric and magnetic fields induced by this source are received on the surface using an array of stations. The project was conducted in three phases. Phase I demonstrated the feasibility of the system to collect static/reference data at the Ketzin CO2 storage pilot site in Germany. In Phase I, numerical modeling was used to determine the optimal configurations and requirements for sensor sensitivity and data accuracy. Based on the model results, existing hardware and software were modified. The CSEM system was then field tested at the Ketzin site. The data were imaged and the results were compared with independent studies of the reservoir and overburden geo-electrical characteristics. Phase II demonstrated the ability to provide sensitive, cost-effective measurement of changes in reservoir properties and changes in the overlying formations using a second round of measurements at the Ketzin site. A prototype autonomous recording system was developed and tested as a subset of the measurement points. Phase III of the project quantified the advantages (and disadvantages) of the fully autonomous data collection subsystems by comparing them with repeated measurements made with mobile stations. The Phase III also provided an additional time point in measuring post

  4. Expert monitoring and verbal feedback as sources of performance pressure.

    Science.gov (United States)

    Buchanan, John J; Park, Inchon; Chen, Jing; Mehta, Ranjana K; McCulloch, Austin; Rhee, Joohyun; Wright, David L

    2018-05-01

    The influence of monitoring-pressure and verbal feedback on the performance of the intrinsically stable bimanual coordination patterns of in-phase and anti-phase was examined. The two bimanual patterns were produced under three conditions: 1) no-monitoring, 2) monitoring-pressure (viewed by experts), and 3) monitoring-pressure (viewed by experts) combined with verbal feedback emphasizing poor performance. The bimanual patterns were produced at self-paced movement frequencies. Anti-phase coordination was always less stable than in-phase coordination across all three conditions. When performed under conditions 2 and 3, both bimanual patterns were performed with less variability in relative phase across a wide range of self-paced movement frequencies compared to the no-monitoring condition. Thus, monitoring-pressure resulted in performance stabilization rather than degradation and the presence of verbal feedback had no impact on the influence of monitoring pressure. The current findings are inconsistent with the predictions of explicit monitoring theory; however, the findings are consistent with studies that have revealed increased stability for the system's intrinsic dynamics as a result of attentional focus and intentional control. The results are discussed within the contexts of the dynamic pattern theory of coordination, explicit monitoring theory, and action-focused theories as explanations for choking under pressure. Copyright © 2018. Published by Elsevier B.V.

  5. Exploiting Analytics Techniques in CMS Computing Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bonacorsi, D. [Bologna U.; Kuznetsov, V. [Cornell U.; Magini, N. [Fermilab; Repečka, A. [Vilnius U.; Vaandering, E. [Fermilab

    2017-11-22

    The CMS experiment has collected an enormous volume of metadata about its computing operations in its monitoring systems, describing its experience in operating all of the CMS workflows on all of the Worldwide LHC Computing Grid Tiers. Data mining efforts into all these information have rarely been done, but are of crucial importance for a better understanding of how CMS did successful operations, and to reach an adequate and adaptive modelling of the CMS operations, in order to allow detailed optimizations and eventually a prediction of system behaviours. These data are now streamed into the CERN Hadoop data cluster for further analysis. Specific sets of information (e.g. data on how many replicas of datasets CMS wrote on disks at WLCG Tiers, data on which datasets were primarily requested for analysis, etc) were collected on Hadoop and processed with MapReduce applications profiting of the parallelization on the Hadoop cluster. We present the implementation of new monitoring applications on Hadoop, and discuss the new possibilities in CMS computing monitoring introduced with the ability to quickly process big data sets from mulltiple sources, looking forward to a predictive modeling of the system.

  6. Visual selection and maintenance of the cell lines with high plant regeneration ability and low ploidy level in Dianthus acicularis by monitoring with flow cytometry analysis.

    Science.gov (United States)

    Shiba, Tomonori; Mii, Masahiro

    2005-12-01

    Efficient plant regeneration system from cell suspension cultures was established in D. acicularis (2n=90) by monitoring ploidy level and visual selection of the cultures. The ploidy level of the cell cultures closely related to the shoot regeneration ability. The cell lines comprising original ploidy levels (2C+4C cells corresponding to DNA contents of G1 and G2 cells of diploid plant, respectively) showed high regeneration ability, whereas those containing the cells with 8C or higher DNA C-values showed low or no regeneration ability. The highly regenerable cell lines thus selected consisted of compact cell clumps with yellowish color and relatively moderate growth, suggesting that it is possible to select visually the highly regenerable cell lines with the original ploidy level. All the regenerated plantlets from the highly regenerable cell cultures exhibited normal phenotypes and no variations in ploidy level were observed by flow cytometry (FCM) analysis.

  7. Indexed bibliography on tritium: its sources and projections, behavior, measurement and monitoring techniques, health physics aspects, and waste management

    International Nuclear Information System (INIS)

    Dixon, M.N.; Holoway, C.F.; Houser, B.L.; Jacobs, D.G.

    1975-08-01

    References are presented to the world literature on sources of tritium in the environment, the migration of tritium in the environment and uptake by biological materials, monitoring methods, health aspects, and radioactive waste management. Subject, author, and permuted title indexes are included. (U.S.)

  8. Design and commissioning of the photon monitors and optical transport lines for the advanced photon source positron accumulator ring

    International Nuclear Information System (INIS)

    Berg, W.; Yang, B.; Lumpkin, A.; Jones, J.

    1996-01-01

    Two photon monitors have been designed and installed in the positron accumulator ring (PAR) of the Advanced Photon Source. The photon monitors characterize the beam's transverse profile, bunch length, emittance, and energy spread in a nonintrusive manner. An optical transport line delivers synchrotron light from the PAR out of a high radiation environment. Both charge-coupled device and fast-gated, intensified cameras are used to measure the transverse beam profile (0.11 - 1 mm for damped beam) with a resolution of 0.06 mm. A streak camera (θ τ =I ps) is used to measure the bunch length which is in the range of 0.3-1 ns. The design of the various transport components and commissioning results of the photon monitors will be discussed

  9. General-Purpose Monitoring during Speech Production

    Science.gov (United States)

    Ries, Stephanie; Janssen, Niels; Dufau, Stephane; Alario, F.-Xavier; Burle, Boris

    2011-01-01

    The concept of "monitoring" refers to our ability to control our actions on-line. Monitoring involved in speech production is often described in psycholinguistic models as an inherent part of the language system. We probed the specificity of speech monitoring in two psycholinguistic experiments where electroencephalographic activities were…

  10. The Effect of Gamma-ray Detector Energy Resolution on the Ability to Identify Radioactive Sources

    International Nuclear Information System (INIS)

    Nelson, K.E.; Gosnell, T.B.; Knapp, D.A.

    2009-01-01

    This report describes the results of an initial study on radiation detector spectral resolution, along with the underlying methodology used. The study was done as part of an ongoing effort in Detection Modeling and Operational Analysis (DMOA) for the DNDO System Architecture Directorate. The study objective was to assess the impact of energy resolution on radionuclide identification capability, measured by the ability to reliably discriminate between spectra associated with 'threats' (defined as fissile materials) and radioactive 'non-threats' that might be present in the normal stream of commerce. Although numerous factors must be considered in deciding which detector technology is appropriate for a specific application, spectral resolution is a critical one for homeland security applications in which a broad range of non-threat sources are present and very low false-alarm rates are required. In this study, we have proposed a metric for quantifying discrimination capability, and have shown how this metric depends on resolution. In future work we will consider other important factors, such as efficiency and volume, and the relative frequency of spectra known to be discrimination challenges in practical applications

  11. The Roles of Self-Disclosure, Modesty, and Self-Monitoring in the Mentoring Relationship: A Longitudinal Multi-Source Investigation

    Science.gov (United States)

    Blickle, Gerhard; Schneider, Paula B.; Perrewe, Pamela L.; Blass, Fred R.; Ferris, Gerald R.

    2008-01-01

    Purpose: The purpose of this study was to investigate the role of protege self-presentation by self-disclosure, modesty, and self-monitoring in mentoring. Design/methodology/approach: This study used three data sources (i.e. employees, peers, and mentors) and a longitudinal design over a period of two years. Findings: Employee self-disclosure and…

  12. Portal monitor evaluation and test procedure

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Rich, B.L.

    1983-10-01

    The purpose was to develop techniques and procedures to allow users to measure performance and sensitivity of portal monitors. Additionally, a methodology was developed to assist users in optimizing monitor performance. The two monitors tested utilized thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: a) background count rate and the statistical variability, b) detector efficiency at different distances, c) moving source sensitivity for various size sources and speeds, and d) false alarm rates at different background levels. A model was developed for the moving source measurements to compare the experimental data with measured results, and to test whether it is possible to adequately model the behavior of a portal monitor's response to a moving source. The model results were compared with the actual test results. A procedure for testing portal monitors is also given. 1 reference, 9 figures, 8 tables

  13. A global catalogue of large SO2 sources and emissions derived from the Ozone Monitoring Instrument

    Directory of Open Access Journals (Sweden)

    V. E. Fioletov

    2016-09-01

    Full Text Available Sulfur dioxide (SO2 measurements from the Ozone Monitoring Instrument (OMI satellite sensor processed with the new principal component analysis (PCA algorithm were used to detect large point emission sources or clusters of sources. The total of 491 continuously emitting point sources releasing from about 30 kt yr−1 to more than 4000 kt yr−1 of SO2 per year have been identified and grouped by country and by primary source origin: volcanoes (76 sources; power plants (297; smelters (53; and sources related to the oil and gas industry (65. The sources were identified using different methods, including through OMI measurements themselves applied to a new emission detection algorithm, and their evolution during the 2005–2014 period was traced by estimating annual emissions from each source. For volcanic sources, the study focused on continuous degassing, and emissions from explosive eruptions were excluded. Emissions from degassing volcanic sources were measured, many for the first time, and collectively they account for about 30 % of total SO2 emissions estimated from OMI measurements, but that fraction has increased in recent years given that cumulative global emissions from power plants and smelters are declining while emissions from oil and gas industry remained nearly constant. Anthropogenic emissions from the USA declined by 80 % over the 2005–2014 period as did emissions from western and central Europe, whereas emissions from India nearly doubled, and emissions from other large SO2-emitting regions (South Africa, Russia, Mexico, and the Middle East remained fairly constant. In total, OMI-based estimates account for about a half of total reported anthropogenic SO2 emissions; the remaining half is likely related to sources emitting less than 30 kt yr−1 and not detected by OMI.

  14. A Global Catalogue of Large SO2 Sources and Emissions Derived from the Ozone Monitoring Instrument

    Science.gov (United States)

    Fioletov, Vitali E.; McLinden, Chris A.; Krotkov, Nickolay; Li, Can; Joiner, Joanna; Theys, Nicolas; Carn, Simon; Moran, Mike D.

    2016-01-01

    Sulfur dioxide (SO2) measurements from the Ozone Monitoring Instrument (OMI) satellite sensor processed with the new principal component analysis (PCA) algorithm were used to detect large point emission sources or clusters of sources. The total of 491 continuously emitting point sources releasing from about 30 kt yr(exp -1) to more than 4000 kt yr(exp -1) of SO2 per year have been identified and grouped by country and by primary source origin: volcanoes (76 sources); power plants (297); smelters (53); and sources related to the oil and gas industry (65). The sources were identified using different methods, including through OMI measurements themselves applied to a new emission detection algorithm, and their evolution during the 2005- 2014 period was traced by estimating annual emissions from each source. For volcanic sources, the study focused on continuous degassing, and emissions from explosive eruptions were excluded. Emissions from degassing volcanic sources were measured, many for the first time, and collectively they account for about 30% of total SO2 emissions estimated from OMI measurements, but that fraction has increased in recent years given that cumulative global emissions from power plants and smelters are declining while emissions from oil and gas industry remained nearly constant. Anthropogenic emissions from the USA declined by 80% over the 2005-2014 period as did emissions from western and central Europe, whereas emissions from India nearly doubled, and emissions from other large SO2-emitting regions (South Africa, Russia, Mexico, and the Middle East) remained fairly constant. In total, OMI-based estimates account for about a half of total reported anthropogenic SO2 emissions; the remaining half is likely related to sources emitting less than 30 kt yr(exp -1) and not detected by OMI.

  15. 40 CFR 141.132 - Monitoring requirements.

    Science.gov (United States)

    2010-07-01

    ... must monitor for alkalinity in the source water prior to any treatment. Systems must take one paired sample and one source water alkalinity sample per month per plant at a time representative of normal... reduce monitoring for both TOC and alkalinity to one paired sample and one source water alkalinity sample...

  16. Radiation monitoring policy at the advanced light source

    International Nuclear Information System (INIS)

    Donahue, R.; Heinzelman, K.; Perdue, G.

    1998-01-01

    When the accelerator first began operation it was decided that, until we had the necessary dosimetry data to decide otherwise, we would badge the entire worker and experimental population. Each person was issued a dosimetry badge that contained 4 TLD elements. Badges were processed on a monthly basis. After three years of analyzing a total of 65,000 TLD elements, the decision was made to modify the radiation monitoring policy at the ALS. Only those individuals in the workforce that have any potential for exposure, no matter how small, would be badged. Subsequently, DOE conducted an independent review of the ALS radiation monitoring and dosimetry program. This review concluded that the ALS program, if expanded as proposed, would be adequate under the 10 CFR 835 Rule to establish radiation exposures to an acceptable level of confidence. The review team recommended the ALS provide more comprehensive documentation on the basis for its radiation protection and monitoring program. This document describes the technical justification for that program

  17. An integrated, open-source set of tools for urban vulnerability monitoring from Earth observation data

    Science.gov (United States)

    De Vecchi, Daniele; Harb, Mostapha; Dell'Acqua, Fabio; Aurelio Galeazzo, Daniel

    2015-04-01

    Aim: The paper introduces an integrated set of open-source tools designed to process medium and high-resolution imagery with the aim to extract vulnerability indicators [1]. Problem: In the context of risk monitoring [2], a series of vulnerability proxies can be defined, such as the extension of a built-up area or buildings regularity [3]. Different open-source C and Python libraries are already available for image processing and geospatial information (e.g. OrfeoToolbox, OpenCV and GDAL). They include basic processing tools but not vulnerability-oriented workflows. Therefore, it is of significant importance to provide end-users with a set of tools capable to return information at a higher level. Solution: The proposed set of python algorithms is a combination of low-level image processing and geospatial information handling tools along with high-level workflows. In particular, two main products are released under the GPL license: source code, developers-oriented, and a QGIS plugin. These tools were produced within the SENSUM project framework (ended December 2014) where the main focus was on earthquake and landslide risk. Further development and maintenance is guaranteed by the decision to include them in the platform designed within the FP 7 RASOR project . Conclusion: With the lack of a unified software suite for vulnerability indicators extraction, the proposed solution can provide inputs for already available models like the Global Earthquake Model. The inclusion of the proposed set of algorithms within the RASOR platforms can guarantee support and enlarge the community of end-users. Keywords: Vulnerability monitoring, remote sensing, optical imagery, open-source software tools References [1] M. Harb, D. De Vecchi, F. Dell'Acqua, "Remote sensing-based vulnerability proxies in the EU FP7 project SENSUM", Symposium on earthquake and landslide risk in Central Asia and Caucasus: exploiting remote sensing and geo-spatial information management, 29-30th January 2014

  18. EFFECT OF TEACHERS’ ABILITIES ON STUDENTS’ MOTIVATION WITH VARYING LEVELS OF INTELLECTUAL ABILITIES IN THE ECONOMICS

    Directory of Open Access Journals (Sweden)

    BERKOVÁ, Kateřina

    2016-09-01

    Full Text Available Intelligence and motivation are two crucial components of the education process that can significantly influence its efficiency. The level of intelligence determines our ability to learn from experience and to solve a problem successfully, whereas motivational processes energize and organize our behavior to reach our goals. This paper is connected to our previous article focused on the influence of teachers’ abilities on secondary business schools’ students’ motivation in the Economics. In our current study, we monitored the motivational potential of teachers’ abilities in a connection with students’ level of intelligence, measured by Vienna Matrices Test. As we would expect according to the results of our previous study, the expertise of teachers has the most important influence in the groups of both the above-average intelligent and the average intelligent students. Nevertheless, we found some differences in other preferences of both groups: except the teachers’ expertise, the average intelligent students refer to be motivated mostly by exposition of curriculum and ability to develop thinking, whereas above-average students refer only about the exposition of curriculum (except the teachers’ expertise. The next factor that we observed in our study is an amount of time that students spend on preparation to school.

  19. Nano-enabled sensors, electronics and energy source on polymer, paper and thread substrates

    Science.gov (United States)

    Mostafalu, Pooria

    Over the past decades, design and development of portable devices for monitoring of biomarkers especially for at risk patients is receiving considerable attention. These devices are either single use diagnostic platforms, wearable on body or on fabric, or they are implanted close to the tissue and organ that it monitors and cures. Sensors, energy sources, and data acquisition devices are the main components of a such monitoring platform. Sensors collect the information using bio-recognition tools such as enzymes and antibodies. Then, the transducers (electrodes, fluorophore, etc) convert it to the appropriate format, for instance electrical and optical signals. After that, data acquisition system amplifies and digitizes the signal and transfers the data to the recording instruments for further processing. Moreover, energy sources are necessary for powering the sensors and electronics. In wearable and implantable applications, these devices need to be flexible, light weight and biocompatible, and their performance should be similar to their rigid counterparts. In this dissertation we address these requirement for wearable and implantable devices. We showed integrated sensors, electronics, and energy sources on flexible polymers, paper, and thread. These devices provide many advantages for monitoring of the physiological condition of a patient and treatment accordingly. Real-time capability of the platform was enabled using wireless telemetry. One of the major innovations of this dissertation is the use of thread as a substrate for making medical diagnostic devices. While conventional substrates (glass, silicon, polyimide, PDMS etc) hold great promise for making wearable and implantable devices, their overall structure and form has remained essentially two dimensional, limiting their function to tissue surfaces such as skin. However, the ability to integrate functional components such as sensors, actuators, and electronics in a way that they penetrate multiple layers

  20. Reliability of Source Mechanisms for a Hydraulic Fracturing Dataset

    Science.gov (United States)

    Eyre, T.; Van der Baan, M.

    2016-12-01

    Non-double-couple components have been inferred for induced seismicity due to fluid injection, yet these components are often poorly constrained due to the acquisition geometry. Likewise non-double-couple components in microseismic recordings are not uncommon. Microseismic source mechanisms provide an insight into the fracturing behaviour of a hydraulically stimulated reservoir. However, source inversion in a hydraulic fracturing environment is complicated by the likelihood of volumetric contributions to the source due to the presence of high pressure fluids, which greatly increases the possible solution space and therefore the non-uniqueness of the solutions. Microseismic data is usually recorded on either 2D surface or borehole arrays of sensors. In many cases, surface arrays appear to constrain source mechanisms with high shear components, whereas borehole arrays tend to constrain more variable mechanisms including those with high tensile components. The abilities of each geometry to constrain the true source mechanisms are therefore called into question.The ability to distinguish between shear and tensile source mechanisms with different acquisition geometries is investigated using synthetic data. For both inversions, both P- and S- wave amplitudes recorded on three component sensors need to be included to obtain reliable solutions. Surface arrays appear to give more reliable solutions due to a greater sampling of the focal sphere, but in reality tend to record signals with a low signal to noise ratio. Borehole arrays can produce acceptable results, however the reliability is much more affected by relative source-receiver locations and source orientation, with biases produced in many of the solutions. Therefore more care must be taken when interpreting results.These findings are taken into account when interpreting a microseismic dataset of 470 events recorded by two vertical borehole arrays monitoring a horizontal treatment well. Source locations and

  1. Developments in radioactive scrap monitoring

    International Nuclear Information System (INIS)

    Bellian, J.G.

    1997-01-01

    Over the past ten years there have been major developments in radiation monitoring systems used for detecting shielded radioactive sources in scrap metal. The extent of the problem and industry's awareness of the problem have both grown significantly during that time. The multimillion dollar expenses associated with decontamination after a source passes into the melt and the potential health hazard to employees and the public have added further impetus to the development of monitoring systems. Early attempts at scrap monitoring could detect some radiation, but testing with real life situations showed them to be virtually incapable of detecting shielded sources of radioactivity in incoming vehicles. More sophisticated detector technology and the development of advanced software made useful by more powerful microprocessors led to successive generations of monitoring systems with order-of-magnitude improvement in detection capability. The next generation includes larger detectors and more complex algorithms offering further improvement in truck and rail car monitoring. Complete solutions require monitoring at additional locations within the site, such as the charge bucket and conveyor lines, and at the scrap processor's site

  2. Source Array Support for Continuous Monitoring of Fish Population and Behavior by Instantaneous Continental-Shelf-Scale Imaging Using Ocean-Waveguide Acoustics

    National Research Council Canada - National Science Library

    Rynne, Ed; Gillette, David

    2006-01-01

    ...) Multistatic ASW Capability Enhancement Program (MACE) as the source of underwater sounds to support active bi-static sonar capabilities for monitoring fish populations and behaviors during a September/October 2006 sea test off the coast of Maine...

  3. IMPLEMENTATION OF OPEN-SOURCE WEB MAPPING TECHNOLOGIES TO SUPPORT MONITORING OF GOVERNMENTAL SCHEMES

    Directory of Open Access Journals (Sweden)

    B. R. Pulsani

    2015-10-01

    Full Text Available Several schemes are undertaken by the government to uplift social and economic condition of people. The monitoring of these schemes is done through information technology where involvement of Geographic Information System (GIS is lacking. To demonstrate the benefits of thematic mapping as a tool for assisting the officials in making decisions, a web mapping application for three government programs such as Mother and Child Tracking system (MCTS, Telangana State Housing Corporation Limited (TSHCL and Ground Water Quality Mapping (GWQM has been built. Indeed the three applications depicted the distribution of various parameters thematically and helped in identifying the areas with higher and weaker distributions. Based on the three applications, the study tends to find similarities of many government schemes reflecting the nature of thematic mapping and hence deduces to implement this kind of approach for other schemes as well. These applications have been developed using SharpMap Csharp library which is a free and open source mapping library for developing geospatial applications. The study highlights upon the cost benefits of SharpMap and brings out the advantage of this library over proprietary vendors and further discusses its advantages over other open source libraries as well.

  4. Radioactive sources and contaminated materials in scrap: monitoring, detection and remedial actions

    International Nuclear Information System (INIS)

    Gallini, R.; Berna, V.; Bonora, A.; Santini, M.

    1999-01-01

    The scrap recycling in steel and other metal mills represents one of the most relevant activities in the Province of Brescia (Lombardy, Italy). In our Province more than 20 million tonnes of metal scrap are recycled every year by a melting process. Since 1990, many accidents which took place were caused by the unwanted melting of radioactive sources, that were probably hidden in metal scrap. In 1993, the Italian Government stated directives to monitor metal scrap imported from non-EC countries because of the suspicion of the illegal traffic of radioactive materials. In 1996, a law imposed the control of all metal scrap, regardless of their origins. Since 1993, our staff have controlled thousands of railway wagons and trucks. Approximately a hundred steel mills and foundries of aluminium, cooper, brass, etc. have also been controlled and many samples have been collected (flue dust, slag, finished products). During these controls, contaminated areas have been brought to light in two warehouses (Cs 137), in 6 companies (Cs 137 and Am 241), in two landfills of industrial waste (Cs 137) and in a quarry (Cs 137). Up to now the contaminated areas have been cleaned, except for the last one. About 150 radioactive sources on contaminated materials have been found in metal scrap. We found radioactive sources of Co 60, Ra 226, Ir 192, Kr 85, Am 241, while the contamination of metals was mainly due to Ra 226. The situation described above justifies an accurate control of the amount of scrap to reduce the risk of contamination of the workers in the working areas, in the environment and in the general public. (author)

  5. Rebound of a coal tar creosote plume following partial source zone treatment with permanganate.

    Science.gov (United States)

    Thomson, N R; Fraser, M J; Lamarche, C; Barker, J F; Forsey, S P

    2008-11-14

    The long-term management of dissolved plumes originating from a coal tar creosote source is a technical challenge. For some sites stabilization of the source may be the best practical solution to decrease the contaminant mass loading to the plume and associated off-site migration. At the bench-scale, the deposition of manganese oxides, a permanganate reaction byproduct, has been shown to cause pore plugging and the formation of a manganese oxide layer adjacent to the non-aqueous phase liquid creosote which reduces post-treatment mass transfer and hence mass loading from the source. The objective of this study was to investigate the potential of partial permanganate treatment to reduce the ability of a coal tar creosote source zone to generate a multi-component plume at the pilot-scale over both the short-term (weeks to months) and the long-term (years) at a site where there is >10 years of comprehensive synoptic plume baseline data available. A series of preliminary bench-scale experiments were conducted to support this pilot-scale investigation. The results from the bench-scale experiments indicated that if sufficient mass removal of the reactive compounds is achieved then the effective solubility, aqueous concentration and rate of mass removal of the more abundant non-reactive coal tar creosote compounds such as biphenyl and dibenzofuran can be increased. Manganese oxide formation and deposition caused an order-of-magnitude decrease in hydraulic conductivity. Approximately 125 kg of permanganate were delivered into the pilot-scale source zone over 35 days, and based on mass balance estimates 35% reduction for all monitored compounds except for biphenyl, dibenzofuran and fluoranthene 150 days after treatment, which is consistent with the bench-scale experimental results. Pre- and post-treatment soil core data indicated a highly variable and random spatial distribution of mass within the source zone and provided no insight into the mass removed of any of the

  6. THE SWIFT/BAT HARD X-RAY TRANSIENT MONITOR

    Energy Technology Data Exchange (ETDEWEB)

    Krimm, H. A.; Holland, S. T.; Corbet, R. H. D.; Pearlman, A. B.; Baumgartner, W. H.; Cummings, J. R. [Center for Research and Exploration in Space Science and Technology (CRESST) and NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Romano, P. [INAF, Istituto di Astrofisica Spaziale e Fisica Cosmica, Via U. La Malfa 153, I-90146 Palermo (Italy); Kennea, J. A. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Bloom, J. S. [Department of Astronomy, University of California, Berkeley, Berkeley, CA 94720-3411 (United States); Barthelmy, S. D.; Gehrels, N.; Lien, A. Y.; Markwardt, C. B.; Ukwatta, T. N. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Palmer, D. M. [Los Alamos National Laboratory, B244, Los Alamos, NM 87545 (United States); Sakamoto, T. [Department of Physics and Mathematics, College of Science and Engineering, Aoyama Gakuin University, 5-10-1 Fuchinobe, Chuo-ku, Sagamihara-shi, Kanagawa 252-5258 (Japan); Stamatikos, M. [Department of Physics and Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH 43210 (United States)

    2013-11-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 s. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public Web site. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries. For the new sources that are previously unpublished, we present basic data analysis and interpretations.

  7. The Swift/BAT Hard X-ray Transient Monitor

    Science.gov (United States)

    Krimm, H. A.; Holland, S. T.; Corbet, R.H.D.; Pearlman, A. B.; Romano, P.; Kennea, J. A.; Bloom, J. S.; Barthelmy, S. D.; Baumgartner, W. H.; Cummings, J. R.; hide

    2013-01-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as ne as 64 seconds. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the ux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public web page. Since 2005 February, 242 sources have been detected in the monitor, 149 of them persistent and 93 detected only in outburst. Among these sources, 16 were previously unknown and discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and ltering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries and present basic data analysis and interpretations for those sources with previously unpublished results.

  8. The Swift-BAT Hard X-Ray Transient Monitor

    Science.gov (United States)

    Krimm, H. A.; Holland, S. T.; Corbet, R. H. D.; Pearlman, A. B.; Romano, P.; Kennea, J. A.; Bloom, J. S.; Barthelmy, S. D.; Baumgartner, W. H.; Cummings, J. R.; hide

    2013-01-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 s. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public Web site. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity and exposure.We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries. For the new sources that are previously unpublished, we present basic data analysis and interpretations.

  9. THE SWIFT/BAT HARD X-RAY TRANSIENT MONITOR

    International Nuclear Information System (INIS)

    Krimm, H. A.; Holland, S. T.; Corbet, R. H. D.; Pearlman, A. B.; Baumgartner, W. H.; Cummings, J. R.; Romano, P.; Kennea, J. A.; Bloom, J. S.; Barthelmy, S. D.; Gehrels, N.; Lien, A. Y.; Markwardt, C. B.; Ukwatta, T. N.; Palmer, D. M.; Sakamoto, T.; Stamatikos, M.

    2013-01-01

    The Swift/Burst Alert Telescope (BAT) hard X-ray transient monitor provides near real-time coverage of the X-ray sky in the energy range 15-50 keV. The BAT observes 88% of the sky each day with a detection sensitivity of 5.3 mCrab for a full-day observation and a time resolution as fine as 64 s. The three main purposes of the monitor are (1) the discovery of new transient X-ray sources, (2) the detection of outbursts or other changes in the flux of known X-ray sources, and (3) the generation of light curves of more than 900 sources spanning over eight years. The primary interface for the BAT transient monitor is a public Web site. Between 2005 February 12 and 2013 April 30, 245 sources have been detected in the monitor, 146 of them persistent and 99 detected only in outburst. Among these sources, 17 were previously unknown and were discovered in the transient monitor. In this paper, we discuss the methodology and the data processing and filtering for the BAT transient monitor and review its sensitivity and exposure. We provide a summary of the source detections and classify them according to the variability of their light curves. Finally, we review all new BAT monitor discoveries. For the new sources that are previously unpublished, we present basic data analysis and interpretations

  10. Web3DGIS-Based System for Reservoir Landslide Monitoring and Early Warning

    Directory of Open Access Journals (Sweden)

    Huang Huang

    2016-02-01

    Full Text Available Landslides are the most frequent type of natural disaster, and they bring about large-scale damage and are a threat to human lives and infrastructure; therefore, the ability to conduct real-time monitoring and early warning is important. In this study, a Web3DGIS (Web3D geographic information systems system for monitoring and forecasting landslides was developed using the Danjiangkou Reservoir area as a case study. The development of this technique involved system construction, functional design, organizing and managing multi-source spatial data, and implementing a forecasting plan and landslide-forecasting model. By integrating sensor technologies, spatial information technologies, 3D visualization technologies, and a landslide-forecasting model, the results of this study provide a tool for real-time monitoring at potential landslide sites. When relevant data from these sites reach threshold values, the model automatically initiates forecasting procedures, and sends information to disaster prevention sectors for emergency management.

  11. Residual DNA-bound proteins are a source of in vitro transcription inhibitor peptides

    International Nuclear Information System (INIS)

    Venanzi, F.M.

    1989-01-01

    Enzymatic breakdown of residual proteins occurs at mild alkaline pH (pH optimum 8.5) as monitored by using radioiodinated, purified genomic DNA from calf thymus. These DNA fibers also possess a differential ability to hydrolyze added exogenous small and linker histones. The results described argue strongly that a putative protease activity, co-purified with DNA, is the source of short chain peptides which inhibit transcription in vitro. Therefore, we propose that RNA repressor peptides must be of higher molecular weight than previously reported

  12. Biofilm-Forming Abilities of Listeria monocytogenes Serotypes Isolated from Different Sources

    Science.gov (United States)

    Doijad, Swapnil P.; Barbuddhe, Sukhadeo B.; Garg, Sandeep; Poharkar, Krupali V.; Kalorey, Dewanand R.; Kurkure, Nitin V.; Rawool, Deepak B.; Chakraborty, Trinad

    2015-01-01

    A total of 98 previously characterized and serotyped L. monocytogenes strains, comprising 32 of 1/2a; 20 of 1/2b and 46 of 4b serotype, from clinical and food sources were studied for their capability to form a biofilm. The microtiter plate assay revealed 62 (63.26%) strains as weak, 27 (27.55%) strains as moderate, and 9 (9.18%) strains as strong biofilm formers. Among the strong biofilm formers, 6 strains were of serotype 1/2a and 3 strains were of serotype 1/2b. None of the strain from 4b serotype exhibited strong biofilm formation. No firm correlation (p = 0.015) was noticed between any serotype and respective biofilm formation ability. Electron microscopic studies showed that strong biofilm forming isolates could synthesize a biofilm within 24 h on surfaces important in food industries such as stainless steel, ceramic tiles, high-density polyethylene plastics, polyvinyl chloride pipes, and glass. Cell enumeration of strong, moderate, and weak biofilm was performed to determine if the number of cells correlated with the biofilm-forming capabilities of the isolates. Strong, moderate, and weak biofilm showed 570±127× 103 cells/cm2, 33±26× 103 cells/cm2, 5±3× 103 cells/cm2, respectively, indicating that the number of cells was directly proportional to the strength of the biofilm. The hydrophobicity index (HI) analysis revealed higher hydrophobicity with an increased biofilm formation. Fatty acid methyl esterase analysis revealed the amount of certain fatty acids such as iso-C15:0, anteiso-C15:0, and anteiso-C17:0 fatty acids correlated with the biofilm-forming capability of L. monocytogenes. This study showed that different strains of L. monocytogenes form biofilm of different intensities which did not completely correlate with their serotype; however, it correlated with the number of cells, hydrophobicity, and amount of certain fatty acids. PMID:26360831

  13. Biofilm-Forming Abilities of Listeria monocytogenes Serotypes Isolated from Different Sources.

    Directory of Open Access Journals (Sweden)

    Swapnil P Doijad

    Full Text Available A total of 98 previously characterized and serotyped L. monocytogenes strains, comprising 32 of 1/2a; 20 of 1/2b and 46 of 4b serotype, from clinical and food sources were studied for their capability to form a biofilm. The microtiter plate assay revealed 62 (63.26% strains as weak, 27 (27.55% strains as moderate, and 9 (9.18% strains as strong biofilm formers. Among the strong biofilm formers, 6 strains were of serotype 1/2a and 3 strains were of serotype 1/2b. None of the strain from 4b serotype exhibited strong biofilm formation. No firm correlation (p = 0.015 was noticed between any serotype and respective biofilm formation ability. Electron microscopic studies showed that strong biofilm forming isolates could synthesize a biofilm within 24 h on surfaces important in food industries such as stainless steel, ceramic tiles, high-density polyethylene plastics, polyvinyl chloride pipes, and glass. Cell enumeration of strong, moderate, and weak biofilm was performed to determine if the number of cells correlated with the biofilm-forming capabilities of the isolates. Strong, moderate, and weak biofilm showed 570±127× 103 cells/cm2, 33±26× 103 cells/cm2, 5±3× 103 cells/cm2, respectively, indicating that the number of cells was directly proportional to the strength of the biofilm. The hydrophobicity index (HI analysis revealed higher hydrophobicity with an increased biofilm formation. Fatty acid methyl esterase analysis revealed the amount of certain fatty acids such as iso-C15:0, anteiso-C15:0, and anteiso-C17:0 fatty acids correlated with the biofilm-forming capability of L. monocytogenes. This study showed that different strains of L. monocytogenes form biofilm of different intensities which did not completely correlate with their serotype; however, it correlated with the number of cells, hydrophobicity, and amount of certain fatty acids.

  14. Offshore platform sourced pollution monitoring using space-borne fully polarimetric C and X band synthetic aperture radar.

    Science.gov (United States)

    Singha, Suman; Ressel, Rudolf

    2016-11-15

    Use of polarimetric SAR data for offshore pollution monitoring is relatively new and shows great potential for operational offshore platform monitoring. This paper describes the development of an automated oil spill detection chain for operational purposes based on C-band (RADARSAT-2) and X-band (TerraSAR-X) fully polarimetric images, wherein we use polarimetric features to characterize oil spills and look-alikes. Numbers of near coincident TerraSAR-X and RADARSAT-2 images have been acquired over offshore platforms. Ten polarimetric feature parameters were extracted from different types of oil and 'look-alike' spots and divided into training and validation dataset. Extracted features were then used to develop a pixel based Artificial Neural Network classifier. Mutual information contents among extracted features were assessed and feature parameters were ranked according to their ability to discriminate between oil spill and look-alike spots. Polarimetric features such as Scattering Diversity, Surface Scattering Fraction and Span proved to be most suitable for operational services. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. The nature of creativity: The roles of genetic factors, personality traits, cognitive abilities, and environmental sources.

    Science.gov (United States)

    Kandler, Christian; Riemann, Rainer; Angleitner, Alois; Spinath, Frank M; Borkenau, Peter; Penke, Lars

    2016-08-01

    This multitrait multimethod twin study examined the structure and sources of individual differences in creativity. According to different theoretical and metrological perspectives, as well as suggestions based on previous research, we expected 2 aspects of individual differences, which can be described as perceived creativity and creative test performance. We hypothesized that perceived creativity, reflecting typical creative thinking and behavior, should be linked to specific personality traits, whereas test creativity, reflecting maximum task-related creative performance, should show specific associations with cognitive abilities. Moreover, we tested whether genetic variance in intelligence and personality traits account for the genetic component of creativity. Multiple-rater and multimethod data (self- and peer reports, observer ratings, and test scores) from 2 German twin studies-the Bielefeld Longitudinal Study of Adult Twins and the German Observational Study of Adult Twins-were analyzed. Confirmatory factor analyses yielded the expected 2 correlated aspects of creativity. Perceived creativity showed links to openness to experience and extraversion, whereas tested figural creativity was associated with intelligence and also with openness. Multivariate behavioral genetic analyses indicated that the heritability of tested figural creativity could be accounted for by the genetic component of intelligence and openness, whereas a substantial genetic component in perceived creativity could not be explained. A primary source of individual differences in creativity was due to environmental influences, even after controlling for random error and method variance. The findings are discussed in terms of the multifaceted nature and construct validity of creativity as an individual characteristic. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  16. Source Water Management for Disinfection By-Product Control using New York City's Operations Support Tool and On-Line Monitoring

    Science.gov (United States)

    Weiss, W. J.; Becker, W.; Schindler, S.

    2012-12-01

    The United States Environmental Protection Agency's 2006 Stage 2 Disinfectant / Disinfection Byproduct Rule (DBPR) for finished drinking waters is intended to reduce overall DBP levels by limiting the levels of total trihalomethanes (TTHM) and five of the haloacetic acids (HAA5). Under Stage 2, maximum contaminant levels (MCLs), 80 μg/L for TTHM and 60 μg/L for HAA5, are based on a locational running annual average for individual sites instead of as the system-wide quarterly running annual average of the Stage 1 DBPR. This means compliance will have to be met at sampling locations of peak TTHM and HAA5 concentrations rather than an average across the entire system. Compliance monitoring under the Stage 2 DBPR began on April 1, 2012. The New York City (NYC) Department of Environmental Protection (DEP) began evaluating potential impacts of the Stage 2 DBPR on NYC's unfiltered water supply in 2002 by monitoring TTHM and HAA5 levels at various locations throughout the distribution system. Initial monitoring indicated that HAA5 levels could be of concern in the future, with the potential to intermittently violate the Stage 2 DBPR at specific locations, particularly those with high water age. Because of the uncertainty regarding the long-term prospect for compliance, DEP evaluated alternatives to ensure compliance, including operational changes (reducing chlorine dose, changing flow configurations to minimize water age, altering pH, altering source water withdrawals); changing the residual disinfectant from free chlorine to chloramines; and engineered treatment alternatives. This paper will discuss the potential for using DEP's Operations Support Tool (OST) and enhanced reservoir monitoring to support optimization of source water withdrawals to minimize finished water DBP levels. The OST is a state-of-the-art decision support system (DSS) to provide computational and predictive support for water supply operations and planning. It incorporates a water supply system

  17. Monitoring physical properties of a submarine groundwater discharge source at Kalogria Bay, SW Peloponnissos, Greece

    Directory of Open Access Journals (Sweden)

    Papathanassiou E.

    2012-04-01

    Full Text Available An impressive SGD in Kalogria Bay (SW Peloponnissos was surveyed for the first time in 2006, revealing the existence of 2 major and 2 minor point sources of freshwater (salinity ~l-2; the discharge was ~ 1000 m3 h−1. The major point source was located in a karstic cavity at 25 m depth. In July 2009, and for a period of one year, the site was monitored intensively. During summer, the underwater discharge was not very strong, the water was flowing from many dispersed points, and salinity range was 20–36. During autumn and winter, flow velocity increased considerably (> 1 m s−1, and the SGDs discharged water of low salinity (< 2. Gradually, the smaller SGDs ceased their operation, and the major SGD emanated brackish water during spring and summer, thus hampering the possibilities of freshwater exploitation, in a touristic area which suffers from great aridity and water demand is high during summer.

  18. Attentional ability among survivors of leukaemia.

    Science.gov (United States)

    Rodgers, J; Horrocks, J; Britton, P G; Kernahan, J

    1999-04-01

    Attentional ability in 19 survivors of acute lymphoblastic leukaemia and 19 sibling controls was assessed using a neuropsychological model of attention. Analysis revealed that children who had received treatment for leukaemia exhibited significantly poorer performance on measures of the "focus encode" and "focus execute" elements of attention and on measures of the ability to respond to external cues and feedback. No significant differences in performance were found for measures of sustained attention and the ability to shift attention. These results indicate that children who have received treatment for leukaemia may experience highly specific attentional deficits that could have an impact on academic performance, particularly mathematical and reading skills. It is suggested that this underlying attentional deficit might be the source of the neuropsychological sequelae associated with the disease. Future attempts at remediation should incorporate activities specifically designed to ameliorate focusing difficulties.

  19. EPA's Radioactive Source Program

    International Nuclear Information System (INIS)

    Kopsick, D.

    2004-01-01

    The US EPA is the lead Federal agency for emergency responses to unknown radiological materials, not licensed, owned or operated by a Federal agency or an Agreement state (Federal Radiological Emergency Response Plan, 1996). The purpose of EPA's clean materials programme is to keep unwanted and unregulated radioactive material out of the public domain. This is achieved by finding and securing lost sources, maintaining control of existing sources and preventing future losses. The focus is on both, domestic and international fronts. The domestic program concentrates on securing lost sources, preventing future losses, alternative technologies like tagging of radioactive sources in commerce, pilot radioactive source roundup, training programs, scrap metal and metal processing facilities, the demolition industry, product stewardship and alternatives to radioactive devices (fewer radioactive source devices means fewer orphan sources). The international program consists of securing lost sources, preventing future losses, radiation monitoring of scrap metal at ports and the international scrap metal monitoring protocol

  20. Performance of the Lancelot Beam Position Monitor at the Diamond Light Source

    Science.gov (United States)

    Chagani, H.; Garcia-Nathan, T. B.; Jiang, C.; Kachatkou, A.; Marchal, J.; Omar, D.; Tartoni, N.; van Silfhout, R. G.; Williams, S.

    2017-12-01

    The Lancelot beam position and profile monitor records the scattered radiation off a thin, low-density foil, which passes through a pinhole perpendicular to the path of the beam and is detected by a Medipix3RX sensor. This arrangement does not expose the detector to the direct beam at synchrotrons and results in a negligible drop in flux downstream of the module. It allows for magnified images of the beam to be acquired in real time with high signal-to-noise ratios, enabling measurements of tiny displacements in the position of the centroid of approximately 1 μm. It also provides a means for independently measuring the photon energy of the incident monoenergetic photon beam. A constant frame rate of up to 245 Hz is achieved. The results of measurements with two Lancelot detectors installed in different environments at the Diamond Light Source are presented and their performance is discussed.

  1. The Ability to Tap to a Beat Relates to Cognitive, Linguistic, and Perceptual Skills

    Science.gov (United States)

    Tierney, Adam T.; Kraus, Nina

    2013-01-01

    Reading-impaired children have difficulty tapping to a beat. Here we tested whether this relationship between reading ability and synchronized tapping holds in typically-developing adolescents. We also hypothesized that tapping relates to two other abilities. First, since auditory-motor synchronization requires monitoring of the relationship…

  2. Geosfear? - Overcoming System Boundaries by Open-source Based Monitoring of Spatio-temporal Processes

    Science.gov (United States)

    Brandt, T.; Schima, R.; Goblirsch, T.; Paschen, M.; Francyk, B.; Bumberger, J.; Zacharias, S.; Dietrich, P.; Rubin, Y.; Rinke, K.; Fleckenstein, J. H.; Schmidt, C.; Vieweg, M.

    2016-12-01

    The impact of global change, intensive agriculture and complex interactions between humans and the environment show different effects on different scales. However, the desire to obtain a better understanding of ecosystems and process dynamics in nature accentuates the need for observing these processes at higher temporal and spatial resolutions. Especially with regard to the process dynamics and heterogeneity of rivers and catchment areas, a comprehensive monitoring of the ongoing processes and effects remains to be a challenging issue. What we need are monitoring systems which can collect most diverse data across different environmental compartments and scales. Today, open-source based electronics and innovative sensors and sensor components are offering a promising approach to investigate new possibilities of mobile data acquisition to improve our understanding of the geosphere. To start with, we have designed and implemented a multi-operable, embedded Linux platform for fast integration of different sensors within a single infrastructure. In addition, a GPS module in combination with a GSM transmitter ensures the synchronization and geo-referencing of all data, no matter how old-fashioned the sensors are. To this end, initial field experiments were conducted at a 3rd order stream in the Central German Lowland. Here, we linked in-stream DOC inputs with subsurface metabolism by coupling miniaturized DOC sensor probes with a modified vertical oxygen profiler in situ. Starting from metrological observations to water quality and subsurface conditions, the overarching goal is the detection of interlinked process dynamics across highly reactive biogeochemical interfaces. Overall, the field experiments demonstrated the feasibility of this emerging technology and its potential towards a cutting-edge strategy based on a holistic and integrated process. Now, we are only a few steps away from realizing adaptive and event-triggered observations close to real

  3. 40 CFR 74.61 - Monitoring plan.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring plan. 74.61 Section 74.61... OPT-INS Monitoring Emissions: Combustion Sources § 74.61 Monitoring plan. (a) Monitoring plan. The... monitoring plan that includes the information required in a monitoring plan under § 75.53 of this chapter...

  4. Uncertainty Monitoring by Young Children in a Computerized Task

    Directory of Open Access Journals (Sweden)

    Michael J. Beran

    2012-01-01

    Full Text Available Adult humans show sophisticated metacognitive abilities, including the ability to monitor uncertainty. Unfortunately, most measures of uncertainty monitoring are limited to use with adults due to their general complexity and dependence on explicit verbalization. However, recent research with nonhuman animals has successfully developed measures of uncertainty monitoring that are simple and do not require explicit verbalization. The purpose of this study was to investigate metacognition in young children using uncertainty monitoring tests developed for nonhumans. Children judged whether stimuli were more pink or blue—stimuli nearest the pink-blue midpoint were the most uncertain and the most difficult to classify. Children also had an option to acknowledge difficulty and gain the necessary information for correct classification. As predicted, children most often asked for help on the most difficult stimuli. This result confirms that some metacognitive abilities appear early in cognitive development. The tasks of animal metacognition research clearly have substantial utility for exploring the early developmental roots of human metacognition.

  5. Monitoring biodiversity change through effective global coordination

    NARCIS (Netherlands)

    Navarro, Laetitia M.; Fernandez, Nestor; Guerra, Carlos; Guralnick, Rob; Kissling, W. Daniel; Londono, Maria Cecilia; Muller-Karger, Frank; Turak, Eren; El Serafy, G.Y.H.; Balvanera, Patricia; Authors, More

    2017-01-01

    The ability to monitor changes in biodiversity, and their societal impact, is critical to conserving species and managing ecosystems. While emerging technologies increase the breadth and reach of data acquisition, monitoring efforts are still spatially and temporally fragmented, and taxonomically

  6. Development of the work function monitoring method for a converter of a negative ion source

    International Nuclear Information System (INIS)

    Yamaoka, Hitoshi; Sasao, Mamiko; Wada, Motoi; Ramos, H.J.

    1988-07-01

    A method to monitor the change in the work function of the converter surface in a self-extraction negative ion source is developed. The photoelectron emission from the Cs-Mo surface in a plasma is detected by irradiating surface with laser lights. Negative ions produced at the surface shows a strong correlation with the photoelectron current from the surface in hydrogen and helium discharges. The photoelectron current induced by the Ar + laser is used to detect the change in the cesium coverage, or the work function, while that by the dye laser is found to be suitable to confirm the region of the work function minimum. (author)

  7. Sensitivity and offset calibration for the beam position monitors at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Chung, Y.; Barr, D.; Decker, G.; Evans, K. Jr.; Kahana, E.

    1995-01-01

    The beam position monitors (BPMs) play a critically important role in commissioning and operation of accelerators. Accurate determination of the offsets relative to the magnetic axis and sensitivities of individual BPMs is thus needed. We will describe in this paper the schemes for calibrating all of the 360 BPMs for sensitivity and offset in the 7-GeV Advanced Photon Source (APS) storage ring and the results. For the sensitivity calibration, a 2-dimensional map of the BPM response in the aluminum vacuum chamber is obtained theoretically, which is combined with the measured nonlinear response of the BPM electronics. A set of 2-dimensional polynomial coefficients is then obtained to approximate the result analytically. The offset calibration of the BPMs is done relative to the magnetic axis of the quadrupoles using the beam. This avoids the problem arising from various mechanical sources as well as the offset in the processing electronics. The measurement results for the resolution and long-term drift of the BPM electronics shows 0.06-μm/√Hz resolution and 2-μm/hr drift over a period of 1.5 hrs

  8. AE monitoring simplified using digital memory storage and source isolation

    International Nuclear Information System (INIS)

    Hutton, P.H.; Skorpik, J.R.

    1977-01-01

    The general trend in acoustic emission (AE) monitoring systems has been one of increasing complexity. This is particularly true in systems for continuous monitoring which are usually multichannel (perhaps 20 to 40) and incorporate a dedicated minicomputer. A unique concept which reverses this trend for selected applications has been developed at Battelle-Northwest, Richland, WA. This concept uses solid state digital memories to store acquired data in a permanent form which is easily retrieved. It also uses a fundamental method to accept AE data only from a selected area. The digital memory system is designed for short term or long term (months) monitoring. It has been successfully applied in laboratory testing such as fatigue crack growth studies, as well as field monitoring on bridges and piping to detect crack growth. The features of simplicity, versatility, and low cost contribute to expanded practical application of acoustic emission technology

  9. Arctic Terrestrial Biodiversity Monitoring Plan

    DEFF Research Database (Denmark)

    Christensen, Tom; Payne, J.; Doyle, M.

    The Conservation of Arctic Flora and Fauna (CAFF), the biodiversity working group of the Arctic Council, established the Circumpolar Biodiversity Monitoring Program (CBMP) to address the need for coordinated and standardized monitoring of Arctic environments. The CBMP includes an international...... on developing and implementing long-term plans for monitoring the integrity of Arctic biomes: terrestrial, marine, freshwater, and coastal (under development) environments. The CBMP Terrestrial Expert Monitoring Group (CBMP-TEMG) has developed the Arctic Terrestrial Biodiversity Monitoring Plan (CBMP......-Terrestrial Plan/the Plan) as the framework for coordinated, long-term Arctic terrestrial biodiversity monitoring. The goal of the CBMP-Terrestrial Plan is to improve the collective ability of Arctic traditional knowledge (TK) holders, northern communities, and scientists to detect, understand and report on long...

  10. Investigation on supervising and monitoring of major radioactive pollution source

    International Nuclear Information System (INIS)

    Zeng Yibing; Zhang Zongrang; Men Meng; Zhang Peng

    2005-01-01

    Objective: In order to optimize the supervisory monitoring proposal of the major radioactive enterprises. Methods: The authors have worked out the public doses within the range of 0-1 km as well as 1-2 km through monitoring analysis of the radioactive pollutant enterprises on the samples of its surrounding air, water, soil and organism. Results: Generally the pollutant range of the enterprises runs from 0 to 1.5 km. Conclusion: Unnecessary working hours can be shortened as long as we keep the routine supervisory monitor of pollutant enterprises within the range of 2 km. (authors)

  11. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  12. Lack of agreement and trending ability of the endotracheal cardiac output monitor compared with thermodilution

    DEFF Research Database (Denmark)

    Møller-Sørensen, H; Hansen, K L; Ostergaard, M

    2012-01-01

    BACKGROUND: Minimally invasive monitoring systems of central haemodynamics are gaining increasing popularity. The present study investigated the precision of the endotracheal cardiac output monitor (ECOM) system and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring...

  13. Newspaper Reading among College Students in Development of Their Analytical Ability

    Science.gov (United States)

    Kumar, Dinesh

    2009-01-01

    The study investigated the newspaper reading among college students in development of their analytical ability. Newspapers are one of the few sources of information that are comprehensive, interconnected and offered in one format. The main objective of the study was to find out the development of the analytical ability among college students by…

  14. Geophysical Methods for Monitoring Temperature Changes in Shallow Low Enthalpy Geothermal Systems

    Directory of Open Access Journals (Sweden)

    Thomas Hermans

    2014-08-01

    Full Text Available Low enthalpy geothermal systems exploited with ground source heat pumps or groundwater heat pumps present many advantages within the context of sustainable energy use. Designing, monitoring and controlling such systems requires the measurement of spatially distributed temperature fields and the knowledge of the parameters governing groundwater flow (permeability and specific storage and heat transport (thermal conductivity and volumetric thermal capacity. Such data are often scarce or not available. In recent years, the ability of electrical resistivity tomography (ERT, self-potential method (SP and distributed temperature sensing (DTS to monitor spatially and temporally temperature changes in the subsurface has been investigated. We review the recent advances in using these three methods for this type of shallow applications. A special focus is made regarding the petrophysical relationships and on underlying assumptions generally needed for a quantitative interpretation of these geophysical data. We show that those geophysical methods are mature to be used within the context of temperature monitoring and that a combination of them may be the best choice regarding control and validation issues.

  15. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    Science.gov (United States)

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for

  16. The Continuous Monitoring of Desert Dust using an Infrared-based Dust Detection and Retrieval Method

    Science.gov (United States)

    Duda, David P.; Minnis, Patrick; Trepte, Qing; Sun-Mack, Sunny

    2006-01-01

    Airborne dust and sand are significant aerosol sources that can impact the atmospheric and surface radiation budgets. Because airborne dust affects visibility and air quality, it is desirable to monitor the location and concentrations of this aerosol for transportation and public health. Although aerosol retrievals have been derived for many years using visible and near-infrared reflectance measurements from satellites, the detection and quantification of dust from these channels is problematic over bright surfaces, or when dust concentrations are large. In addition, aerosol retrievals from polar orbiting satellites lack the ability to monitor the progression and sources of dust storms. As a complement to current aerosol dust retrieval algorithms, multi-spectral thermal infrared (8-12 micron) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Meteosat-8 Spinning Enhanced Visible and Infrared Imager (SEVIRI) are used in the development of a prototype dust detection method and dust property retrieval that can monitor the progress of Saharan dust fields continuously, both night and day. The dust detection method is incorporated into the processing of CERES (Clouds and the Earth s Radiant Energy System) aerosol retrievals to produce dust property retrievals. Both MODIS (from Terra and Aqua) and SEVERI data are used to develop the method.

  17. Geophysical monitoring as an information source of rock massif behaviour

    Directory of Open Access Journals (Sweden)

    Pavel Bláha

    2008-06-01

    Full Text Available Geophysical measurements are an integral part of engineering-geological investigation where theypresent a wide range of useful information about the tested geological medium and about its geotechnicalqualities. Lately, repeated geophysical measurements in different time intervals have been used to judgethe changes occurring in the rock massif. These measurements bear the characteristics of total monitoring.This total monitoring contains series of repeated measurements and further an integrated spectrum of linkedactivities including evaluation, comparison with the warning state and making a decision about takingprecautions. From the range of geophysical methods and methodologies used for monitoring in full sensewe may mention, for example, continuous seismoacoustic measurements in mining constructions; (whichmay result even in recalling of the personnel, and further, also seismic measurements in the surroundingsof atomic power stations and measurements considering the protection against radioactive elements and their decay components.As a full monitoring we may also classify measurements in dumping sites with the aid of repeated geoelectrical measurements in the system of fixed electrodes under impermeable foils.These measurements are mostly carried out from time to time followed by taking immediate action when the foil is found damaged. In practice the term monitoring is used, although not very correctly, for all periodically repeated measurements, which do not result in taking action or interference, but supply a wide range of information about the rock massif behavior in time.

  18. Efficient species-level monitoring at the landscape scale

    Science.gov (United States)

    Barry R. Noon; Larissa L. Bailey; Thomas D. Sisk; Kevin S. McKelvey

    2012-01-01

    Monitoring the population trends of multiple animal species at a landscape scale is prohibitively expensive. However, advances in survey design, statistical methods, and the ability to estimate species presence on the basis of detection­nondetection data have greatly increased the feasibility of species-level monitoring. For example, recent advances in monitoring make...

  19. Development of computer-based function to estimate radioactive source term by coupling atmospheric model with monitoring data

    International Nuclear Information System (INIS)

    Akiko, Furuno; Hideyuki, Kitabata

    2003-01-01

    Full text: The importance of computer-based decision support systems for local and regional scale accidents has been recognized by many countries with the experiences of accidental atmospheric releases of radionuclides at Chernobyl in 1986 in the former Soviet Union. The recent increase of nuclear power plants in the Asian region also necessitates an emergency response system for Japan to predict the long-range atmospheric dispersion of radionuclides due to overseas accident. On the basis of these backgrounds, WSPEEDI (Worldwide version of System for Prediction of Environmental Emergency Dose Information) at Japan Atomic Energy Research Institute is developed to forecast long-range atmospheric dispersions of radionuclides during nuclear emergency. Although the source condition is critical parameter for accurate prediction, it is rarely that the condition can be acquired in the early stage of overseas accident. Thus, we have been developing a computer-based function to estimate radioactive source term, e.g. the release point, time and amount, as a part of WSPEEDI. This function consists of atmospheric transport simulations and statistical analysis for the prediction and monitoring of air dose rates. Atmospheric transport simulations are carried out for the matrix of possible release points in Eastern Asia and possible release times. The simulation results of air dose rates are compared with monitoring data and the best fitted release condition is defined as source term. This paper describes the source term estimation method and the application to Eastern Asia. The latest version of WSPEEDI accommodates following two models: an atmospheric meteorological model MM5 and a particle random walk model GEARN. MM5 is a non-hydrostatic meteorological model developed by the Pennsylvania State University and the National Center for Atmospheric Research (NCAR). MM5 physically calculates more than 40 meteorological parameters with high resolution in time and space based an

  20. Online Sources of Competitive Intelligence.

    Science.gov (United States)

    Wagers, Robert

    1986-01-01

    Presents an approach to using online sources of information for competitor intelligence (i.e., monitoring industry and tracking activities of competitors); identifies principal sources; and suggests some ways of making use of online databases. Types and sources of information and sources and database charts are appended. Eight references are…

  1. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  2. Real time monitoring of electron processors

    International Nuclear Information System (INIS)

    Nablo, S.V.; Kneeland, D.R.; McLaughlin, W.L.

    1995-01-01

    A real time radiation monitor (RTRM) has been developed for monitoring the dose rate (current density) of electron beam processors. The system provides continuous monitoring of processor output, electron beam uniformity, and an independent measure of operating voltage or electron energy. In view of the device's ability to replace labor-intensive dosimetry in verification of machine performance on a real-time basis, its application to providing archival performance data for in-line processing is discussed. (author)

  3. Post decommissioning monitoring of uranium mines; a watershed monitoring program based on biological response

    International Nuclear Information System (INIS)

    Russel, C.; Coggan, A.; Ludgate, I.

    2006-01-01

    Rio Algom Limited and Denison Mines own and operated uranium mines in the Elliot Lake area. The mines operated from the late 1950's to the mid 1960's and again for the early 1970's to the 1990's when the mines ceased operations. There are eleven decommissioned mines in the Serpent River watershed. At the time of decommissioning each mine had it's own monitoring program, which had evolved over the operating life of the mine and did not necessarily reflect the objectives associated with the monitoring of decommissioned sites. In order to assess the effectiveness of the decommissioning plans and monitoring the cumulative effects within the watershed, a single watershed monitoring program was developed in 1999: the Serpent River Watershed Monitoring Program which focused on water and sediment quality within the watershed and response of the biological community over time. In order to address other 'source area' monitoring, three complimentary objective-focused programs were developed 1) the In- Basin Monitoring Program, 2) the Source Area Monitoring Program and 3) the TMA Operational Monitoring Program. Through development this program framework and monitoring programs that were objective- focused, more meaningful data has been provided while providing a significant reduction in the cost of monitoring. These programs allow for the reduction in scope over time in response to improvement in the watershed. This talk will describe the development of these programs, their implementation and effectiveness. (author)

  4. Verifying mapping, monitoring and modeling of fine sediment pollution sources in West Maui, Hawai'i, USA

    Science.gov (United States)

    Cerovski-Darriau, C.; Stock, J. D.

    2017-12-01

    Coral reef ecosystems, and the fishing and tourism industries they support, depend on clean waters. Fine sediment pollution from nearshore watersheds threatens these enterprises in West Maui, Hawai'i. To effectively mitigate sediment pollution, we first have to know where the sediment is coming from, and how fast it erodes. In West Maui, we know that nearshore sediment plumes originate from erosion of fine sand- to silt-sized air fall deposits where they are exposed by grazing, agriculture, or other disturbances. We identified and located these sediment sources by mapping watershed geomorphological processes using field traverses, historic air photos, and modern orthophotos. We estimated bank lowering rates using erosion pins, and other surface erosion rates were extrapolated from data collected elsewhere on the Hawaiian Islands. These measurements and mapping led to a reconnaissance sediment budget which showed that annual loads are dominated by bank erosion of legacy terraces. Field observations during small storms confirm that nearshore sediment plumes are sourced from bank erosion of in-stream, legacy agricultural deposits. To further verify this sediment budget, we used geochemical fingerprinting to uniquely identify each potential source (e.g. stream banks, agricultural fields, roads, other human modified soils, and hillslopes) from the Wahikuli watershed (10 km2) and analyzed the fine fraction using ICP-MS for elemental geochemistry. We propose to apply this the fingerprinting results to nearshore suspended sediment samples taken during storms to identify the proportion of sediment coming from each source. By combining traditional geomorphic mapping, monitoring and geochemistry, we hope to provide a powerful tool to verify the primary source of sediment reaching the nearshore.

  5. Monitoring Technology Meets Care Work

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Bygholm, Ann

    2015-01-01

    's ability to meet the complexity of care work. Understanding intersectional challenges between these care technologies and care work is fundamental to improve design and use of health informatics. In this paper we present an analysis of interaction challenges between a wet-sensor at the task of monitoring......Monitoring technology, especially sensor-based technology, is increasingly taken into use in care work. Despite the simplicity of these technologies – aimed to automate what appear as mundane monitoring tasks – recent research has identified major challenges primarily related to the technology...... wet beds at a nursing home. The analysis identifies the multifaceted nature of monitoring work and the intricacy of integrating sensor technology into the complex knowledge system of monitoring work....

  6. Pressure monitoring and characterization of external sources of contamination at the site of the payment drinking water epidemiological studies.

    Science.gov (United States)

    Besner, Marie-Claude; Broséus, Romain; Lavoie, Jean; Giovanni, George Di; Payment, Pierre; Prévost, Michèle

    2010-01-01

    The 1990s epidemiological studies by Payment and colleagues suggested that an increase in gastrointestinal illnesses observed in the population consuming tap water from a system meeting all water quality regulations might be associated with distribution system deficiencies. In the current study, the vulnerability of this distribution system to microbial intrusion was assessed by characterizing potential sources of contamination near pipelines and monitoring the frequency and magnitude of negative pressures. Bacterial indicators of fecal contamination were recovered more frequently in the water from flooded air-valve vaults than in the soil or water from pipe trenches. The level of fecal contamination in these various sources was more similar to levels from river water rather than wastewater. Because of its configuration, this distribution system is vulnerable to negative pressures when pressure values out of the treatment plant reach or drop below 172 kPa (25 psi), which occurred nine times during a monitoring period of 17 months. The results from this investigation suggest that this distribution system is vulnerable to contamination by intrusion. Comparison of the frequency of occurrence of negative pressure events and repair rates with data from other distribution systems suggests that the system studied by Payment and colleagues is not atypical.

  7. Alternative uses of a megavolt tandem accelerator for few-keV studies with ion-source SIMS monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Mello, S. L. A., E-mail: smello@ufv.br [Departamento de Física, Universidade Federal de Viçosa, 36570-900 Viçosa, MG (Brazil); Codeço, C. F. S.; Magnani, B. F.; Sant’Anna, M. M. [Instituto de Física, Universidade Federal do Rio de Janeiro, 21941-972 Rio de Janeiro, RJ (Brazil)

    2016-06-15

    We increase the versatility of a tandem electrostatic accelerator by implementing simple modifications to the standard operation procedure. While keeping its ability to deliver MeV ion beams, we show that the experimental setup can (i) provide good quality ion beams in the few-keV energy range and (ii) be used to study ion-beam surface modification with simultaneous secondary ion mass spectrometry. This latter task is accomplished without using any chamber connected to the accelerator exit. We perform mass spectrometry of the few-keV anions produced in the ion source by measuring their neutral counterparts at the accelerator exit with energies up to 1.7 MeV. With an additional modification, a high-current few-keV regime is obtained, using the ion source as an irradiation chamber and the accelerator itself only as a mass spectrometer. As an example of application, we prepare a sample for the study of ion-beam assisted dewetting of a thin Au film on a Si substrate.

  8. Timing matters: negative emotion elicited 5 min but not 30 min or 45 min after learning enhances consolidation of internal-monitoring source memory.

    Science.gov (United States)

    Wang, Bo; Bukuan, Sun

    2015-05-01

    Two experiments examined the time-dependent effects of negative emotion on consolidation of item and internal-monitoring source memory. In Experiment 1, participants (n=121) learned a list of words. They were asked to read aloud half of the words and to think about the remaining half. They were instructed to memorize each word and its associative cognitive operation ("reading" versus "thinking"). Immediately following learning they conducted free recall and then watched a 3-min either neutral or negative video clip when 5 min, 30 min or 45 min had elapsed after learning. Twenty-four hours later they returned to take surprise tests for item and source memory. Experiment 2 was similar to Experiment 1 except that participants, without conducting an immediate test of free recall, took tests of source memory for all encoded words both immediately and 24 h after learning. Experiment 1 showed that negative emotion enhanced consolidation of item memory (as measured by retention ratio of free recall) regardless of delay of emotion elicitation and that negative emotion enhanced consolidation of source memory when it was elicited at a 5 min delay but reduced consolidation of source memory when it was elicited at a 30 min delay; when elicited at a 45 min delay, negative emotion had little effect. Furthermore, Experiment 2 replicated the enhancement effect on source memory in the 5 min delay even when participants were tested on all the encoded words. The current study partially replicated prior studies on item memory and extends the literature by providing evidence for a time-dependent effect of negative emotion on consolidation of source memory based on internal monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    International Nuclear Information System (INIS)

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q.

    2015-01-01

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery

  10. Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Taoran, E-mail: taoran.li.duke@gmail.com; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q. [Department of Radiation Oncology, Duke University Medical Center Durham, North Carolina 27710 (United States)

    2015-01-15

    Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery

  11. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.

    Science.gov (United States)

    Li, Taoran; Wu, Qiuwen; Yang, Yun; Rodrigues, Anna; Yin, Fang-Fang; Jackie Wu, Q

    2015-01-01

    An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system's performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Online adapted plans were

  12. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  13. Wide-area monitoring to detect undeclared nuclear facilities

    International Nuclear Information System (INIS)

    Wogman, N.

    1994-09-01

    The International Atomic Energy Agency (IAEA) is committed to strengthening and streamlining the overall effectiveness of the IAEA safeguards system. The IAEA is investigating the use of environmental monitoring techniques to strengthen its capability to detect undeclared nuclear activities. The IAEA's Program 93+2 Initiative has been established to develop, test, and assess strengthening techniques and measures. Some of the techniques have been validated and are being implemented during routine safeguards inspections. The effectiveness of other techniques is being studied as a part of extensive field trials conducted at nuclear facilities of various Member States during 1993 and 1994. Proposals based on the results of these investigations and recommendations for new safeguards activities are expected to be presented to the March 1995 Board of Governors Meeting. The techniques in use or under study during IAEA field trials address various types of environmental monitoring applications as outlined under Program 93+2's Task 3, Environmental Monitoring Techniques for Safeguards Applications, namely, the use of short-range monitoring during inspections and visits to investigate sites of possible undeclared activities. With the exception of wide-area water sampling in Iraq, the use of long-range monitoring, in the absence of any indication of undeclared nuclear activities, remains largely unexamined by the IAEA. The efficacy of long-range monitoring depends on the availability of mobile signature isotopes or compounds and on the ability to distinguish the nuclear signatures from background signals and attributing them to a source. The scope of this paper is to provide technical information to the International Atomic Energy Agency (IAEA) on possible wide-area survey techniques for the detection of undeclared nuclear activities. The primary focus is the detection of effluents from reprocessing activities

  14. Monitoring and Managing Fatigue in Basketball

    Directory of Open Access Journals (Sweden)

    Toby Edwards

    2018-02-01

    Full Text Available The sport of basketball exposes athletes to frequent high intensity movements including sprinting, jumping, accelerations, decelerations and changes of direction during training and competition which can lead to acute and accumulated chronic fatigue. Fatigue may affect the ability of the athlete to perform over the course of a lengthy season. The ability of practitioners to quantify the workload and subsequent fatigue in basketball athletes in order to monitor and manage fatigue levels may be beneficial in maintaining high levels of performance and preventing unfavorable physical and physiological training adaptations. There is currently limited research quantifying training or competition workload outside of time motion analysis in basketball. In addition, systematic research investigating methods to monitor and manage athlete fatigue in basketball throughout a season is scarce. To effectively optimize and maintain peak training and playing performance throughout a basketball season, potential workload and fatigue monitoring strategies need to be discussed.

  15. High-resolution continuum source atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple lines. A critical review of current possibilities

    International Nuclear Information System (INIS)

    Resano, M.; Flórez, M.R.; García-Ruiz, E.

    2013-01-01

    This work examines the capabilities and limitations of commercially available high-resolution continuum source atomic absorption spectrometry instrumentation for multi-line monitoring, discussing in detail the possible strategies to develop multi-element methodologies that are truly simultaneous, or else sequential, but from the same sample aliquot. Moreover, the simultaneous monitoring of various atomic or molecular lines may bring other important analytical advantages, such as: i) expansion of the linear range by monitoring multiplets; ii) improvements in the limit of detection and in precision by summing the signals from different lines of the same element or molecule; iii) simple correction for matrix-effects by selecting a suitable internal standard; or iv) accurate mathematical correction of spectral overlaps by simultaneous monitoring of free lines of the interfering molecule or element. This work discusses how authors have made use of these strategies to develop analytical methodologies that permit the straightforward analysis of complex samples. - Highlights: • HR CS AAS potential for simultaneous multi-line monitoring is critically examined. • Strategies to develop simultaneous multi-element methods are discussed. • Other benefits of multi-line monitoring (e.g., use of an IS or LSBC) are highlighted. • Selected examples from the literature are discussed in detail

  16. Bayesian Inference for Signal-Based Seismic Monitoring

    Science.gov (United States)

    Moore, D.

    2015-12-01

    Traditional seismic monitoring systems rely on discrete detections produced by station processing software, discarding significant information present in the original recorded signal. SIG-VISA (Signal-based Vertically Integrated Seismic Analysis) is a system for global seismic monitoring through Bayesian inference on seismic signals. By modeling signals directly, our forward model is able to incorporate a rich representation of the physics underlying the signal generation process, including source mechanisms, wave propagation, and station response. This allows inference in the model to recover the qualitative behavior of recent geophysical methods including waveform matching and double-differencing, all as part of a unified Bayesian monitoring system that simultaneously detects and locates events from a global network of stations. We demonstrate recent progress in scaling up SIG-VISA to efficiently process the data stream of global signals recorded by the International Monitoring System (IMS), including comparisons against existing processing methods that show increased sensitivity from our signal-based model and in particular the ability to locate events (including aftershock sequences that can tax analyst processing) precisely from waveform correlation effects. We also provide a Bayesian analysis of an alleged low-magnitude event near the DPRK test site in May 2010 [1] [2], investigating whether such an event could plausibly be detected through automated processing in a signal-based monitoring system. [1] Zhang, Miao and Wen, Lianxing. "Seismological Evidence for a Low-Yield Nuclear Test on 12 May 2010 in North Korea". Seismological Research Letters, January/February 2015. [2] Richards, Paul. "A Seismic Event in North Korea on 12 May 2010". CTBTO SnT 2015 oral presentation, video at https://video-archive.ctbto.org/index.php/kmc/preview/partner_id/103/uiconf_id/4421629/entry_id/0_ymmtpps0/delivery/http

  17. Finnish experiences of health monitoring: local, regional, and national data sources for policy evaluation

    Directory of Open Access Journals (Sweden)

    Katri Kilpeläinen

    2016-02-01

    Full Text Available Background: Finland has a long tradition of gathering information about the health and welfare of the adult population. Design: Surveys and administrative registers form the basis for national and local health monitoring in Finland. Results: Different data sources are used in Finland to develop key indicators, which can be used to evaluate how the national health policy targets have been met in different parts of the country and in different population subgroups. Progress has been shown in chronic disease risk factors, such as smoking reduction. However, some health policy targets have not been met. Socioeconomic health differences, for example, have remained large compared with other European countries. Conclusion: Although data availability for key health indicators is good in Finland, there is a need for wider and more comprehensive use of this information by political decision-makers and healthcare professionals.

  18. Agile infrastructure monitoring

    International Nuclear Information System (INIS)

    Andrade, P; Ascenso, J; Fedorko, I; Fiorini, B; Paladin, M; Pigueiras, L; Santos, M

    2014-01-01

    At the present time, data centres are facing a massive rise in virtualisation and cloud computing. The Agile Infrastructure (AI) project is working to deliver new solutions to ease the management of CERN data centres. Part of the solution consists in a new 'shared monitoring architecture' which collects and manages monitoring data from all data centre resources. In this article, we present the building blocks of this new monitoring architecture, the different open source technologies selected for each architecture layer, and how we are building a community around this common effort.

  19. The role of reinstating generation operations in recognition memory and reality monitoring

    Directory of Open Access Journals (Sweden)

    Nieznański Marek

    2014-09-01

    Full Text Available The role of encoding/retrieval conditions compatibility was investigated in a reality-monitoring task. An experiment was conducted which showed a positive effect of reinstating distinctive encoding operations at test. That is, generation of a low-frequency (LF word from the same word fragment at study and test significantly enhanced item recognition memory. However, reinstating of relatively more automatic operations of reading or generating a highfrequency (HF word did not influence recognition performance. Moreover, LF words were better recognized than HF words, but memory for source did not depend on the encoding/retrieval match or on the word-frequency. In comparison with reading, generating an item at study significantly enhanced source memory but generating it at test had no effect. The data were analysed using a multinomial modelling approach which allowed ruling out the influence of a response bias on the measurement of memory ability.

  20. Comparative study of two modes of gastroesophageal reflux measuring: conventional esophageal pH monitoring and wireless pH monitoring

    Directory of Open Access Journals (Sweden)

    Rimon Sobhi Azzam

    2012-06-01

    Full Text Available CONTEXT: Esophageal pH monitoring is considered to be the gold standard for the diagnosis of gastroesophageal acid reflux. However, this method is very troublesome and considerably limits the patient's routine activities. Wireless pH monitoring was developed to avoid these restrictions. OBJECTIVE: To compare the first 24 hours of the conventional and wireless pH monitoring, positioned 3 cm above the lower esophageal sphincter, in relation to: the occurrence of relevant technical failures, the ability to detect reflux and the ability to correlate the clinical symptoms to reflux. METHODS: Twenty-five patients referred for esophageal pH monitoring and with typical symptoms of gastroesophageal reflux disease were studied prospectively, underwent clinical interview, endoscopy, esophageal manometry and were submitted, with a simultaneous initial period, to 24-hour catheter pH monitoring and 48-hour wireless pH monitoring. RESULTS: Early capsule detachment occurred in one (4% case and there were no technical failures with the catheter pH monitoring (P = 0.463. Percentages of reflux time (total, upright and supine were higher with the wireless pH monitoring (P < 0.05. Pathological gastroesophageal reflux occurred in 16 (64% patients submitted to catheter and in 19 (76% to the capsule (P = 0.355. The symptom index was positive in 12 (48% patients with catheter pH monitoring and in 13 (52% with wireless pH monitoring (P = 0.777. CONCLUSIONS: 1 No significant differences were reported between the two methods of pH monitoring (capsule vs catheter, in regard to relevant technical failures; 2 Wireless pH monitoring detected higher percentages of reflux time than the conventional pH-metry; 3 The two methods of pH monitoring were comparable in diagnosis of pathological gastroesophageal reflux and comparable in correlating the clinical symptoms with the gastroesophageal reflux.

  1. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  2. Impacts of Different Water Pollution Sources on Antioxidant Defense Ability in Three Aquatic Macrophytes in Assiut Province, Egypt

    Directory of Open Access Journals (Sweden)

    Mohamed A.A. Gadallah

    2014-08-01

    Full Text Available The present study was undertaken to evaluate the impacts of surface water pollution with wastes coming from sewage effluents (Site 2, agricultural runoff (Site 4 and oils and detergents factory (Site 3 on the stability of leaf membrane (measured as injury %, hydrogen peroxide (H2O2, ascorbic acid (Asc A, lipid peroxidation, chlorophyll (Chl content, soluble sugars (SS, soluble proteins (SP and total free amino acids (TAA of Cyperus alopeucroides, Persicaria salicifolia and Echinochloa stagnina. Concentration of H2O2, MDA and TAA were higher in the three plants collected from polluted sites as compared with those of plants grown in control Nile site (Site1. The opposite was true for Asc A, SS and SP where their concentrations reduced significantly in response to water pollution. Leaf membrane was more damaged (high injury % in plants exposed to wastes from different sources than in plants growing at control site. The results of this study indicated that water pollution reduced the oxidative defense abilities in the three plants through reduction of Asc A activities, enhancement of H2O2 production and increasing MDA accumulation. In addition it impaired the metabolic activity through lowering the SS and SP contents and enhancement of TAA accumulation and increase membrane injury. The over production of hydrogen peroxide by the studied aquatic plants under water pollution could be used as an oxygen source needed to oxidize the more resistant organic and inorganic pollutants and used for pollution control and municipal and industrial wastewater treatment.

  3. Project W-030 flammable gas verification monitoring test

    International Nuclear Information System (INIS)

    BARKER, S.A.

    1999-01-01

    This document describes the verification monitoring campaign used to document the ability of the new ventilation system to mitigate flammable gas accumulation under steady state tank conditions. This document reports the results of the monitoring campaign. The ventilation system configuration, process data, and data analysis are presented

  4. Enabling social listening for cardiac safety monitoring: Proceedings from a drug information association-cardiac safety research consortium cosponsored think tank.

    Science.gov (United States)

    Seifert, Harry A; Malik, Raleigh E; Bhattacharya, Mondira; Campbell, Kevin R; Okun, Sally; Pierce, Carrie; Terkowitz, Jeffrey; Turner, J Rick; Krucoff, Mitchell W; Powell, Gregory E

    2017-12-01

    This white paper provides a summary of the presentations and discussions from a think tank on "Enabling Social Listening for Cardiac Safety Monitoring" trials that was cosponsored by the Drug Information Association and the Cardiac Safety Research Consortium, and held at the White Oak headquarters of the US Food and Drug Administration on June 3, 2016. The meeting's goals were to explore current methods of collecting and evaluating social listening data and to consider their applicability to cardiac safety surveillance. Social listening is defined as the act of monitoring public postings on the Internet. It has several theoretical advantages for drug and device safety. First, these include the ability to detect adverse events that are "missed" by traditional sources and the ability to detect adverse events sooner than would be allowed by traditional sources, both by affording near-real-time access to data from culturally and geographically diverse sources. Social listening can also potentially introduce a novel patient voice into the conversation about drug safety, which could uniquely augment understanding of real-world medication use obtained from more traditional methodologies. Finally, it can allow for access to information about drug misuse and diversion. To date, the latter 2 of these have been realized. Although regulators from the Food and Drug Administration and the United Kingdom's Medicines and Healthcare Products Regulatory Agency participated in the think tank along with representatives from industry, academia, and patient groups, this article should not be construed to constitute regulatory guidance. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Compact neutron flux monitor

    International Nuclear Information System (INIS)

    Madhavi, V.; Phatak, P.R.; Bahadur, C.; Bayala, A.K.; Jakati, R.K.; Sathian, V.

    2003-01-01

    Full text: A compact size neutron flux monitor has been developed incorporating standard boards developed for smart radiation monitors. The sensitivity of the monitors is 0.4cps/nV. It has been tested up to 2075 nV flux with standard neutron sources. It shows convincing results even in high flux areas like 6m away from the accelerator in RMC (Parel) for 106/107 nV. These monitors have a focal and remote display, alarm function with potential free contacts for centralized control and additional provision of connectivity via RS485/Ethernet. This paper describes the construction, working and results of the above flux monitor

  6. 40 CFR 469.13 - Monitoring.

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY Semiconductor Subcategory § 469.13 Monitoring. (a... management plan submitted to the permitting authority.” (b) In requesting that no monitoring of TTO be...

  7. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  8. The Ability to Assimilate Technology as a Source of Competitive Advantage of Financial Companies in Poland

    Directory of Open Access Journals (Sweden)

    Glabiszewski Waldemar

    2016-12-01

    Full Text Available This article is empirical in nature and attempts to assess the impact of ability to assimilate newly acquired technologies by financial companies operating in Poland gaining market competitive advantages. The outcome of the research conducted proved the existence of this relationship and found it be strong. This means that the development of these abilities within the absorptive potential of financial companies should trigger a significant increase in the market competitive advantages held by them. The strong impact was identified both in the total of the analyzed personnel and general-organizational components of the assimilation abilities. As regards elementary components of the analyzed potential, the obtained results are definitely more diverse.

  9. Preliminary preview for a geographic and monitoring program project; a review of point source-nonpoint source effluent trading/offset systems in watersheds

    Science.gov (United States)

    Wood, Alexander Warren; Bernknopf, Richard L.

    2003-01-01

    Watershed-based trading and offset systems are being developed to improve policy-maker?s and regulator?s ability to assess nonpoint source impacts in watersheds and to evaluate the efficacy of using market-incentive programs for preserving environmental quality. An overview of the history of successful and failed trading programs throughout the United States suggests that certain political, economic, and scientific conditions within a temporal and spatial setting help meet water quality standards. The current lack of spontaneous trading among dischargers does not mean that a marketable permit trading system is an inherently inefficient regulatory approach. Rather, its infrequent use is the result of institutional and informational barriers. Improving and refining the earth science information and technologies may help determine whether trading is a suitable policy for improving water quality. However, it is debatable whether or not environmental information is the limiting factor. This paper reviews additional factors affecting the potential for instituting a trading policy. The motivation for investigating and reviewing the history of offsets and trading was inspired by a project in the preliminary stages being developed by U.S. Geological Survey Western Geographic Science Center and the Environmental Protection Agency Region IX. An offset feasibility study will be an integrated, map-based approach that incorporates environmental, economic, and statistical information to investigate the potential for using offsets to meet mercury Total Maximum Daily Loads in the Sacramento River watershed. A regional water-quality offset program is being studied that may help known point sources reduce mercury loading more cost effectively by the remediation of abandoned mines or other diffuse sources as opposed to more costly treatment at their own sites. An efficient offset program requires both a scientific basis and methods to translate that science into a regulatory decision

  10. Helicopter Rotor Blade Monitoring using Autonomous Wireless Sensor Network

    NARCIS (Netherlands)

    Sanchez Ramirez, Andrea; Loendersloot, Richard; Tinga, Tiedo; Basu, B.

    2013-01-01

    The advancement on Wireless Sensor Networks for vibration monitoring presents important possibilities for helicopter rotor health and usage monitoring. While main rotor blades account for the main source of lift for helicopters, rotor induced vibration establishes an important source for

  11. Verifiable process monitoring through enhanced data authentication

    International Nuclear Information System (INIS)

    Goncalves, Joao G.M.; Schwalbach, Peter; Schoeneman, Barry Dale; Ross, Troy D.; Baldwin, George Thomas

    2010-01-01

    To ensure the peaceful intent for production and processing of nuclear fuel, verifiable process monitoring of the fuel production cycle is required. As part of a U.S. Department of Energy (DOE)-EURATOM collaboration in the field of international nuclear safeguards, the DOE Sandia National Laboratories (SNL), the European Commission Joint Research Centre (JRC) and Directorate General-Energy (DG-ENER) developed and demonstrated a new concept in process monitoring, enabling the use of operator process information by branching a second, authenticated data stream to the Safeguards inspectorate. This information would be complementary to independent safeguards data, improving the understanding of the plant's operation. The concept is called the Enhanced Data Authentication System (EDAS). EDAS transparently captures, authenticates, and encrypts communication data that is transmitted between operator control computers and connected analytical equipment utilized in nuclear processes controls. The intent is to capture information as close to the sensor point as possible to assure the highest possible confidence in the branched data. Data must be collected transparently by the EDAS: Operator processes should not be altered or disrupted by the insertion of the EDAS as a monitoring system for safeguards. EDAS employs public key authentication providing 'jointly verifiable' data and private key encryption for confidentiality. Timestamps and data source are also added to the collected data for analysis. The core of the system hardware is in a security enclosure with both active and passive tamper indication. Further, the system has the ability to monitor seals or other security devices in close proximity. This paper will discuss the EDAS concept, recent technical developments, intended application philosophy and the planned future progression of this system.

  12. Hydrologic monitoring using open-source Arduino logging platforms in a socio-hydrological system of the drought-prone tropics, Guanacaste, Costa Rica

    Science.gov (United States)

    Hund, S. V.; Johnson, M. S.; Steyn, D. G.; Keddie, T.; Morillas, L.

    2015-12-01

    Water supply is highly disputed in the tropics of northwestern Costa Rica where rainfall exhibits high seasonal variability and long annual dry seasons. Water shortages are common during the dry season, and water conflicts emerge between domestic water users, intensively irrigated agriculture, the tourism industry, and ecological flows. Climate change may further increase the variability of precipitation and the risk for droughts, and pose challenges for small rural agricultural communities experiencing water stress. To adapt to seasonal droughts and improve resilience of communities to future changes, it is essential to increase understanding of interactions between components of the coupled hydrological-social system. Yet, hydrological monitoring and data on water use within developing countries of the humid tropics is limited. To address these challenges and contribute to extended monitoring networks, low-cost and open-source monitoring platforms were developed based off Arduino microelectronic boards and software and combined with hydrological sensors to monitor river stage and groundwater levels in two watersheds of Guanacaste, Costa Rica. Hydrologic monitoring stations are located in remote locations and powered by solar panels. Monitoring efforts were made possible through collaboration with local rural communities, and complemented with a mix of digitized water extraction data and community water use narratives to increase understanding of water use and challenges. We will present the development of the Arduino logging system, results of water supply in relation to water use for both the wet and dry season, and discuss these results within a socio-hydrological system context.

  13. Polycyclic Aromatic Hydrocarbons (PAHs) and Hopanes in Plastic Resin Pellets as Markers of Oil Pollution via International Pellet Watch Monitoring.

    Science.gov (United States)

    Yeo, Bee Geok; Takada, Hideshige; Hosoda, Junki; Kondo, Atsuko; Yamashita, Rei; Saha, Mahua; Maes, Thomas

    2017-08-01

    Oil pollution in the marine environment is an unavoidable problem due to chronic input from local sources, particularly in urban areas and oil spills. Oil pollution not only causes immediate physical damages to surrounding wildlife but also some components, including higher molecular weight PAHs, can persist in the environment for many years and pose insidious threats to the ecosystem. Long-term and nontargeted monitoring of oil pollution is important. This paper examines the ability of International Pellet Watch (IPW) for initial identification and monitoring of oil pollution by analysing PAHs and hopanes in plastic pellet samples collected globally by volunteers. PAH concentrations with the sum of 28 parent and methyl PAHs vary geographically, ranging from 0.035 to 24.4 µg/g-pellet, in line with the presence or absence of local oil pollution sources, such as oil refineries or oil spill sites. This suggests that PAHs can be used to monitor petroleum pollution in IPW. A colour-coded categorization for PAH concentrations within IPW monitoring also is established to facilitate data presentation and understanding. PAH concentrations are generally higher in Western Europe, especially around the North Sea shorelines, moderate in East Asia and North America, and lower in South East Asia, Oceania, South America, and Africa. Hopane concentrations, with a smaller spatial variation (1.7-101 µg/g-pellet), showed no spatial pattern. This result and the poor correlation between hopanes and PAHs suggest that hopane concentrations alone are unsuited to identify petroleum pollution. However, hopane compositions can be used for fingerprinting sources of oil pollution. Thus, both PAHs and hopanes in IPW allow for low cost, remote monitoring of global oil pollution.

  14. Handling of radioactive sources in Ecuador

    International Nuclear Information System (INIS)

    Benitez, Manuel

    2000-01-01

    This document describes the following aspects: sealed and unsealed radioactive sources, radiation detectors, personnel and area monitoring, surface pollution, radioactive wastes control and radioactive sources transferring. (The author)

  15. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  16. Preliminary studies on the evolution of carbon assimilation abilities within Mucorales.

    Science.gov (United States)

    Pawłowska, Julia; Aleksandrzak-Piekarczyk, Tamara; Banach, Agnieszka; Kiersztyn, Bartosz; Muszewska, Anna; Serewa, Lidia; Szatraj, Katarzyna; Wrzosek, Marta

    2016-05-01

    Representatives of Mucorales belong to one of the oldest lineages of terrestrial fungi. Although carbon is of fundamental importance for fungal growth and functioning, relatively little is known about enzymatic capacities of Mucorales. The evolutionary history and the variability of the capacity to metabolize different carbon sources among representatives of the order Mucorales was studied using Phenotypic Microarray Plates. The ability of 26 strains belonging to 23 nonpathogenic species of Mucorales to use 95 different carbon sources was tested. Intraspecies variability of carbon assimilation profiles was lower than interspecies variation for some selected strains. Although similarities between the phylogenetic tree and the dendrogram created from carbon source utilization data were observed, the ability of the various strains to use the analyzed substrates did not show a clear correlation with the evolutionary history of the group. Instead, carbon assimilation profiles are probably shaped by environmental conditions. Copyright © 2016 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  17. Activation analysis of stainless steel flux monitors using 252Cf neutron sources

    International Nuclear Information System (INIS)

    Williams, J.G.; Newton, T.H. Jr.; Cogburn, C.O.

    1984-01-01

    Activation analysis was performed on stainless steel beads from a chain which is used in reactor pressure vessel surveillance experiments at the Arkansas Power and Light Company reactors. The beads allow monitoring of two fast and three thermal neutron induced reactions: 58 Ni(n,p) 58 Co, 54 Fe(n,p) 54 Mn, 58 Fe(n,γ) 59 Fe, 59 Co(n,γ) 60 Co and 50 Cr(n,γ) 51 Cr. The analysis was performed using 12 beads from various positions along 5 different batches of chain and standard materials in an H 2 O moderator tank using two intense californium sources which had a total neutron emission rate of 3.97 x 10 10 /s. Semiconductor gamma spectrometers were used to count the products of the above reactions in the specimens. The percentage by weight of the iron, chromium and cobalt in the beads were found to be 62.1%, 20.2% and 0.120%, respectively. The excellent uniformity found in the bead compositions demonstrates the reproducibility of the experimental techniques and enhances considerably the value of the beads as neutron flux montitors

  18. A Risk-Based Multi-Objective Optimization Concept for Early-Warning Monitoring Networks

    Science.gov (United States)

    Bode, F.; Loschko, M.; Nowak, W.

    2014-12-01

    Groundwater is a resource for drinking water and hence needs to be protected from contaminations. However, many well catchments include an inventory of known and unknown risk sources which cannot be eliminated, especially in urban regions. As matter of risk control, all these risk sources should be monitored. A one-to-one monitoring situation for each risk source would lead to a cost explosion and is even impossible for unknown risk sources. However, smart optimization concepts could help to find promising low-cost monitoring network designs.In this work we develop a concept to plan monitoring networks using multi-objective optimization. Our considered objectives are to maximize the probability of detecting all contaminations and the early warning time and to minimize the installation and operating costs of the monitoring network. A qualitative risk ranking is used to prioritize the known risk sources for monitoring. The unknown risk sources can neither be located nor ranked. Instead, we represent them by a virtual line of risk sources surrounding the production well.We classify risk sources into four different categories: severe, medium and tolerable for known risk sources and an extra category for the unknown ones. With that, early warning time and detection probability become individual objectives for each risk class. Thus, decision makers can identify monitoring networks which are valid for controlling the top risk sources, and evaluate the capabilities (or search for least-cost upgrade) to also cover moderate, tolerable and unknown risk sources. Monitoring networks which are valid for the remaining risk also cover all other risk sources but the early-warning time suffers.The data provided for the optimization algorithm are calculated in a preprocessing step by a flow and transport model. Uncertainties due to hydro(geo)logical phenomena are taken into account by Monte-Carlo simulations. To avoid numerical dispersion during the transport simulations we use the

  19. Refurbishing tritium contaminated ion sources

    International Nuclear Information System (INIS)

    Wright, K.E.; Carnevale, R.H.; McCormack, B.E.; Stevenson, T.; Halle, A. von

    1995-01-01

    Extended tritium experimentation on TFTR has necessitated refurbishing Neutral Beam Long Pulse Ion Sources (LPIS) which developed operational difficulties, both in the TFTR Test Cell and later, in the NB Source Refurbishment Shop. Shipping contaminated sources off-site for repair was not permissible from a transport and safety perspective. Therefore, the NB source repair facility was upgraded by relocating fixtures, tooling, test apparatus, and three-axis coordinate measuring equipment; purchasing and fabricating fume hoods; installing exhaust vents; and providing a controlled negative pressure environment in the source degreaser/decon area. Appropriate air flow monitors, pressure indicators, tritium detectors and safety alarms were also included. The effectiveness of various decontamination methods was explored while the activation was monitored. Procedures and methods were developed to permit complete disassembly and rebuild of an ion source while continuously exhausting the internal volume to the TFTR Stack to avoid concentrations of tritium from outgassing and minimize personnel exposure. This paper presents upgrades made to the LPIS repair facility, various repair tasks performed, and discusses the effectiveness of the decontamination processes utilized

  20. Maternal ability to take care of children exposed to HIV

    Directory of Open Access Journals (Sweden)

    Julyana Gomes Freitas

    2013-07-01

    Full Text Available OBJECTIVE: to assess the ability of mothers to take care of children exposed to HIV, using the Assessment Scale of Care Skills for Children Exposed to HIV at Birth and to check the association between the scale dimensions and maternal characteristics. METHOD: this cross-sectional study involved 62 HIV+ mothers whose children of up to one year old had been exposed to the virus at birth. The Assessment Scale of Care Skills for Children Exposed to HIV at Birth consists of 52 items and five dimensions, indicating high, moderate or low care ability. RESULTS: 72.7% of the mothers appropriately offered zidovudine syrup; 86.0% were highly skilled to prepare and administer milk formula; 44.4% were moderately able to prepare and administer complementary feeding; 76.5% revealed high ability to administer prophylactic treatment against pneumonia and 95.3% demonstrated high abilities for clinical monitoring and immunization. Significant associations were found between some maternal variables and the scale dimensions. CONCLUSION: the scale permits the assessment of maternal care delivery to these children and the accomplishment of specific child health interventions.

  1. Proceedings of the 2011 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    International Nuclear Information System (INIS)

    Wetovsky, Marvin A.; Patterson, Eileen F.; Sandoval, Marisa N.

    2011-01-01

    These proceedings contain papers prepared for the Monitoring Research Review 2011: Ground-Based Nuclear Explosion Monitoring Technologies, held 13-15 September, 2011 in Tucson, Arizona. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Defense Threat Reduction Agency (DTRA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), National Science Foundation (NSF), and other invited sponsors. The scientific objectives of the research are to improve the United States' capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  2. Proceedings of the 2011 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wetovsky, Marvin A. [Editor; Patterson, Eileen F. [Editor; Sandoval, Marisa N. [Editor

    2011-09-13

    These proceedings contain papers prepared for the Monitoring Research Review 2011: Ground-Based Nuclear Explosion Monitoring Technologies, held 13-15 September, 2011 in Tucson, Arizona. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Defense Threat Reduction Agency (DTRA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), National Science Foundation (NSF), and other invited sponsors. The scientific objectives of the research are to improve the United States' capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  3. Proceedings of the 30th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Wetovsky, Marv A [Los Alamos National Laboratory; Aguilar-chang, Julio [Los Alamos National Laboratory; Arrowsmith, Marie [Los Alamos National Laboratory; Arrowsmith, Stephen [Los Alamos National Laboratory; Baker, Diane [Los Alamos National Laboratory; Begnaud, Michael [Los Alamos National Laboratory; Harste, Hans [Los Alamos National Laboratory; Maceira, Monica [Los Alamos National Laboratory; Patton, Howard [Los Alamos National Laboratory; Phillips, Scott [Los Alamos National Laboratory; Randall, George [Los Alamos National Laboratory; Revelle, Douglas [Los Alamos National Laboratory; Rowe, Charlotte [Los Alamos National Laboratory; Stead, Richard [Los Alamos National Laboratory; Steck, Lee [Los Alamos National Laboratory; Whitaker, Rod [Los Alamos National Laboratory; Yang, Xiaoning [Los Alamos National Laboratory

    2008-09-23

    These proceedings contain papers prepared for the 30th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies, held 23-25 September, 2008 in Portsmouth, Virginia. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Technical Applications Center (AFTAC), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States’ capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  4. Proceedings of the 2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wetovsky, Marvin A [Editor; Patterson, Eileen F [Editor

    2010-09-21

    These proceedings contain papers prepared for the Monitoring Research Review 2010: Ground-Based Nuclear Explosion Monitoring Technologies, held 21-23 September, 2010 in Orlando, Florida,. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, National Science Foundation (NSF), Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  5. Proceedings of the 2009 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wetovsky, Marv A [Los Alamos National Laboratory; Aguilar - Chang, Julio [Los Alamos National Laboratory; Anderson, Dale [Los Alamos National Laboratory; Arrowsmith, Marie [Los Alamos National Laboratory; Arrowsmith, Stephen [Los Alamos National Laboratory; Baker, Diane [Los Alamos National Laboratory; Begnaud, Michael [Los Alamos National Laboratory; Harste, Hans [Los Alamos National Laboratory; Maceira, Monica [Los Alamos National Laboratory; Patton, Howard [Los Alamos National Laboratory; Phillips, Scott [Los Alamos National Laboratory; Randall, George [Los Alamos National Laboratory; Rowe, Charlotte [Los Alamos National Laboratory; Stead, Richard [Los Alamos National Laboratory; Steck, Lee [Los Alamos National Laboratory; Whitaker, Rod [Los Alamos National Laboratory; Yang, Xiaoning ( David ) [Los Alamos National Laboratory

    2009-09-21

    These proceedings contain papers prepared for the Monitoring Research Review 2009: Ground -Based Nuclear Explosion Monitoring Technologies, held 21-23 September, 2009 in Tucson, Arizona,. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Test Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States’ capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  6. Proceedings of the 2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    International Nuclear Information System (INIS)

    Wetovsky, Marvin A.; Patterson, Eileen F.

    2010-01-01

    These proceedings contain papers prepared for the Monitoring Research Review 2010: Ground-Based Nuclear Explosion Monitoring Technologies, held 21-23 September, 2010 in Orlando, Florida,. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, National Science Foundation (NSF), Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  7. Radioactive Environment Contamination and Abilities of the Modern Radiochemistry in the Field of Nuclear Waste Disposal and Monitoring

    International Nuclear Information System (INIS)

    Myasoedov, B.F.; Novikov, A.P.

    1999-01-01

    The study of environmental contamination caused by anthropogenic impacts and, primarily, by radioactive nuclides is one of the main scientific problems facing contemporary science. This is known as Radioecological monitoring. Decisions regarding the remediation of polluted areas require detailed information about the distribution of radioactive nuclides in terrestrial and aquatic ecosystems, as well as, knowledge about radionuclides occurrence forms and migration patterns. Different sources of radionuclides penetration into the environment appoint their interaction with nature matrices in different ways and should be considered accordingly. An overview is given of the present radioecological situation around the reprocessing plant M ayak , which was constructed more than 40 years ago for the production of plutonium for military purposes. Some new approaches, methods and tools developed at the Vernadsky Institute of Geochemistry and Analytical Chemistry for the isolation, concentration and determination of radionuclides in various environmental samples are discussed. Data regarding the distribution, occurrence, and migration processes of radionuclides 90 Sr, 137 Cs, 239 Pu and 241 Am, in aquatic and terrestrial ecosystems of the impact zone of the Mayak plant, are presented

  8. Development and Validation of a Multimedia-based Assessment of Scientific Inquiry Abilities

    Science.gov (United States)

    Kuo, Che-Yu; Wu, Hsin-Kai; Jen, Tsung-Hau; Hsu, Ying-Shao

    2015-09-01

    The potential of computer-based assessments for capturing complex learning outcomes has been discussed; however, relatively little is understood about how to leverage such potential for summative and accountability purposes. The aim of this study is to develop and validate a multimedia-based assessment of scientific inquiry abilities (MASIA) to cover a more comprehensive construct of inquiry abilities and target secondary school students in different grades while this potential is leveraged. We implemented five steps derived from the construct modeling approach to design MASIA. During the implementation, multiple sources of evidence were collected in the steps of pilot testing and Rasch modeling to support the validity of MASIA. Particularly, through the participation of 1,066 8th and 11th graders, MASIA showed satisfactory psychometric properties to discriminate students with different levels of inquiry abilities in 101 items in 29 tasks when Rasch models were applied. Additionally, the Wright map indicated that MASIA offered accurate information about students' inquiry abilities because of the comparability of the distributions of student abilities and item difficulties. The analysis results also suggested that MASIA offered precise measures of inquiry abilities when the components (questioning, experimenting, analyzing, and explaining) were regarded as a coherent construct. Finally, the increased mean difficulty thresholds of item responses along with three performance levels across all sub-abilities supported the alignment between our scoring rubrics and our inquiry framework. Together with other sources of validity in the pilot testing, the results offered evidence to support the validity of MASIA.

  9. Next generation x-ray all-sky monitor

    International Nuclear Information System (INIS)

    Priedhorsky, W. C.; Peele, A. G.; Nugent, K. A.

    1997-01-01

    We set forth a conceptual design for x-ray all-sky monitor based on lobster-eye wide-field telescopes. This instrument, suitable for a small satellite, would monitor the flux of objects as faint as 2x10 -15 W/m 2 (0.5-2.4 keV) on a daily basis with a signal-to-noise of 5. Sources would be located to 1-2 arc-minutes. Detailed simulations show that crosstalk from the cruciform lobster images would not significantly compromise performance. At this sensitivity limit, we could monitor not just x-ray binaries but fainter classes of x-ray sources. Hundreds of active galactic nuclei, coronal sources, and cataclysmic variables could be tracked on a daily basis. Large numbers of fast transients should be visible, including gamma-ray bursts and the soft x-ray breakout of nearby type II supernovae. Long-term x-ray measurements will advance our understanding of the geometries and perhaps masses of AGN, and coronal energy sources in stars

  10. Source Location of Noble Gas Plumes

    International Nuclear Information System (INIS)

    Hoffman, I.; Ungar, K.; Bourgouin, P.; Yee, E.; Wotawa, G.

    2015-01-01

    In radionuclide monitoring, one of the most significant challenges from a verification or surveillance perspective is the source location problem. Modern monitoring/surveillance systems employ meteorological source reconstruction — for example, the Fukushima accident, CRL emissions analysis and even radon risk mapping. These studies usually take weeks to months to conduct, involving multidisciplinary teams representing meteorology; dispersion modelling; radionuclide sampling and metrology; and, when relevant, proper representation of source characteristics (e.g., reactor engineering expertise). Several different approaches have been tried in an attempt to determine useful techniques to apply to the source location problem and to develop rigorous methods that combine all potentially relevant observations and models to identify a most probable source location and size with uncertainties. The ultimate goal is to understand the utility and limitations of these techniques so they can transition from R&D to operational tools. (author)

  11. Design of Kartini reactor radiation monitor system using lab view

    International Nuclear Information System (INIS)

    Adi Abimanyu; Jumari; Achmad Fahrul Aji; Muhammad Khoiri

    2014-01-01

    Kartini Reactor operation will result in radiation exposure. Gamma radiation exposure rate at the Kartini Reactor monitored by several radiation monitors (Ludlum) that integrate with the computer, so that the rate of radiation exposure is always monitored. Current monitoring system combines six radiation monitor in one computer monitor radiation, and monitoring performed by operators and supervisors to see how the radiation exposure rate measured in the area around the reactor core in a periodic time manually. This research will develop a system to monitor radiation exposure in Kartini reactor based ATMega8 micro controller for interface between radiation monitor and computer and also Graphical User Interface (GUI) develop using Lab view software that makes monitoring is easier and documented regularly. This system is testing by simulation, it is done by replacing the function of the radiation monitoring devices (Ludlum) in Kartini Reactor with computers that send serial data with the same format with a format that is sent by Ludlum. The results show that the interface system has the ability to operate in a range of baud rate 1,200 bps, 2,400 bps, 4,800 bps, 9,600 bps, 14,400 bps, 19,200 bps and 38,400 bps, with the ability to provide realtime information every 6 seconds and able to document the rate of exposure to radiation in the form of logbook. (author)

  12. The assessment of natural scaffolds ability in chondrogenic ...

    African Journals Online (AJOL)

    The ability of cartilage to repair damage is limited due to lack of blood vessels and low cell density. Recently, tissue engineering is considerably preferred to other treatments as a way to solve this problem. Regardless of cell sources, one of the crucial factors in tissue engineering is to select an appropriate scaffold, which is ...

  13. Ion source with plasma cathode

    International Nuclear Information System (INIS)

    Yabe, E.

    1987-01-01

    A long lifetime ion source with plasma cathode has been developed for use in ion implantation. In this ion source, a plasma of a nonreactive working gas serves as a cathode in place of a thermionic tungsten filament used in the Freeman ion source. In an applied magnetic field, the plasma is convergent, i.e., filamentlike; in zero magnetic field, it turns divergent and spraylike. In the latter case, the plasma exhibits a remarkable ability when the working gas has an ionization potential larger than the feed gas. By any combination of a working gas of either argon or neon and a feed gas of AsF 5 or PF 5 , the lifetime of this ion source was found to be more than 90 h with an extraction voltage of 40 kV and the corresponding ion current density 20 mA/cm 2 . Mass spectrometry results show that this ion source has an ability of generating a considerable amount of As + and P + ions from AsF 5 and PF 5 , and hence will be useful for realizing a fully cryopumped ion implanter system. This ion source is also eminently suitable for use in oxygen ion production

  14. An overview of passive remote sensing for post-fire monitoring

    Directory of Open Access Journals (Sweden)

    2005-01-01

    Full Text Available Monitoring of forest burnt areas has several aims: to locate and estimate the extent of such areas; to assess the damages suffered by the forest stands; to check the ability of the ecosystem to naturally recover after the fire; to support the planning of reclamation interventions; to assess the dynamics (pattern and speed of the natural recovery; to check the outcome of any eventual restoration intervention. Remote sensing is an important source of information to support all such tasks. In the last decades, the effectiveness of remotely sensed imagery is increasing due to the advancement of tools and techniques, and to the lowering of the costs, in relative terms. For an effective support to post-fire management (burnt scar perimeter mapping, damage severity assessment, post-fire vegetation monitoring, a mapping scale of at least 1:10000-1:20000 is required: hence, the selection of remotely sensed data is restricted to aerial imagery and to satellite imagery characterized by high (HR and, above all, very high (VHR spatial resolution. In the last decade, HR and VHR passive remote sensing has widespread, providing affordable multitemporal and multispectral pictures of the considered phenomena, at different scales (spatial, temporal and spectral resolutions with reference to the monitoring needs. In the light of such a potential, the integration of GPS field survey and HR (Landsat 7, Spot HVR and VHR satellite imagery (Ikonos, Quickbird, Spot 5 is currently sought as a highly viable option for the post-fire monitoring.

  15. Suitability of monitoring methods for the optimisation of Radiological Protection in the case of internal exposure through inhalation

    International Nuclear Information System (INIS)

    Degrange, J.P.; Gibert, B.; Basire, D.

    2000-01-01

    The radiological protection system recommended by the International Commission for Radiological Protection (ICRP) for justified practices relied pn the limitation and optimisation principles. The monitoring of internal exposure is most often based on the periodic assessment of individual exposure in order to essentially insure the simple compliance with the annual dose limits. Optimisation of protection implies a realistic, sensitive and analytical assessment of individual and collective exposures in order to allow the indentification of the main sources of exposure (main sources of contamination, most exposed operators, work activities contributing the most to the exposure) and the selection of the optimal protection options. Therefore the monitoring methods must allow the realistic assessment of individual dose levels far lower than annual limits together with measurements as frequent as possible. The aim of this presentation is to discuss the ability of various monitoring methods (collective and individual air sampling, in vivo and in vitro bioassays) to fulfil those needs. This discussion is illustrated by the particular case of the internal exposure to natural uranium compounds through inhalation. Firstly, the sensitivity and the degree to which each monitoring method is realistic are quantified and discussed on the basis of the application of the new ICRP dosimetric model, and their analytical capability for the optimisation of radiological protection is then indicated. Secondly, a case study is presented which shows the capability of individual air sampling techniques to analyse the exposure of the workers and the inadequacy of static air sampling to accurately estimate the exposures when contamination varies significantly over time and space in the workstations. As far as exposure to natural uranium compounds through inhalation is concerned, the study for assessing the sensitivity, analytic ability and accuracy of the different measuring systems shows that

  16. Design and implementation of a scalable monitor system (IF-monitor) for Linux clusters

    International Nuclear Information System (INIS)

    Zhang Weiyi; Yu Chuansong; Sun Gongxing; Gu Ming

    2003-01-01

    PC clusters have become a cost-effective solution for high performance computing, usually only with the abilities of resource management and job scheduling, and unfortunately, with lack of powerful monitoring for built PC Farms. Therefore it is like a 'black box' for administrators who don't know how they run and where the bottlenecks are. In present there are a few of running PC Farms such as BES-Farm, LHC-Farm, YBJ-Farm at IHEP, CAS. As the scale of PC Farms growing and the IHEP campus grid computing environment implemented, it is more difficult to predict how these PC Farms perform. As a result, the SNMP-based tool called IF-Monitor that allows effective monitoring of large clusters have been designed and developed at IHEP. (authors)

  17. Analysis backpropagation methods with neural network for prediction of children's ability in psychomotoric

    Science.gov (United States)

    Izhari, F.; Dhany, H. W.; Zarlis, M.; Sutarman

    2018-03-01

    A good age in optimizing aspects of development is at the age of 4-6 years, namely with psychomotor development. Psychomotor is broader, more difficult to monitor but has a meaningful value for the child's life because it directly affects his behavior and deeds. Therefore, there is a problem to predict the child's ability level based on psychomotor. This analysis uses backpropagation method analysis with artificial neural network to predict the ability of the child on the psychomotor aspect by generating predictions of the child's ability on psychomotor and testing there is a mean squared error (MSE) value at the end of the training of 0.001. There are 30% of children aged 4-6 years have a good level of psychomotor ability, excellent, less good, and good enough.

  18. Evaluation of Antioxidant and Free Radical Scavenging Abilities of ...

    African Journals Online (AJOL)

    Objective: This study was aimed at determining the antioxidants and free radical scavenging abilities of some packaged fruit juices (PFJ) widely used as source of fluids in Nigeria. Materials and methods: Packaged fruit juice samples produced by The Coca cola Company and Chi company namely: Apple(AP), blackcurrant, ...

  19. Behavioral and electrophysiological evidence of enhanced performance monitoring in meditators

    NARCIS (Netherlands)

    Andreu, C.I.; Moënne-Loccoz, C.; López, V.; Slagter, H.A.; Franken, I.H.A.; Cosmelli, D.

    2017-01-01

    Performance monitoring—the ability to monitor ongoing performance to detect and correct errors—is a core component of cognitive control. Impairments in performance monitoring have been associated with several psychiatric disorders, including attention deficit hyperactivity disorder and substance use

  20. Low cost monitoring from space using Landsat TM time series and open source technologies: the case study of Iguazu park

    Science.gov (United States)

    Nole, Gabriele; Lasaponara, Rosa

    2015-04-01

    Up to nowadays, satellite data have become increasingly available, thus offering a low cost or even free of charge unique tool, with a great potential for operational monitoring of vegetation cover, quantitative assessment of urban expansion and urban sprawl, as well as for monitoring of land use changes and soil consumption. This growing observational capacity has also highlighted the need for research efforts aimed at exploring the potential offered by data processing methods and algorithms, in order to exploit as much as possible this invaluable space-based data source. The work herein presented concerns an application study on the monitoring of vegetation cover and urban sprawl conducted with the use of satellite Landsat TM data. The selected test site is the Iguazu park highly significant, being it one of the most threatened global conservation priorities (http://whc.unesco.org/en/list/303/). In order to produce synthetic maps of the investigated areas to monitor the status of vegetation and ongoing subtle changes, satellite Landsat TM data images were classified using two automatic classifiers, Maximum Likelihood (MLC) and Support Vector Machines (SVMs) applied by changing setting parameters, with the aim to compare their respective performances in terms of robustness, speed and accuracy. All process steps have been developed integrating Geographical Information System and Remote Sensing, and adopting free and open source software. Results pointed out that the SVM classifier with RBF kernel was generally the best choice (with accuracy higher than 90%) among all the configurations compared, and the use of multiple bands globally improves classification. One of the critical elements found in the case of monitoring of urban area expansion is given by the presence of urban garden mixed with urban fabric. The use of different configurations for the SVMs, i.e. different kernels and values of the setting parameters, allowed us to calibrate the classifier also to

  1. Monitoring the energy scale of KATRIN with conversion electrons of a solid {sup 83m}Kr source as nuclear standard

    Energy Technology Data Exchange (ETDEWEB)

    Schloesser, Klaus [IKP, Karlsruher Institut fuer Technologie (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    For KATRIN to be able to achieve the desired sensitivity of 200 meV/c{sup 2} for the effective electron neutrino mass, it is of crucial importance that the energy scale of the main spectrometer (18.6 keV) is under control within +/-60 mV at any given time over the planned measurement time of approximately 5 years. Besides conventional high voltage dividers and high precision volt meters, a nuclear standard will be deployed additionally in a separate spectrometer of MAC-E filter type. The filter electrodes of both spectrometers are connected galvanically. For permanent and continuous monitoring an easy to use ion implanted source containing the noble gas {sup 83m}Kr was developed and qualified for HV monitoring at the ppm level in the 30 kV regime. This talk presents the methods applied and the achievements made.

  2. Neutron area monitor with TLD pairs

    International Nuclear Information System (INIS)

    Guzman G, K. A.; Borja H, C. G.; Valero L, C.; Hernandez D, V. M.; Vega C, H. R.

    2011-11-01

    The response of a passive neutron area monitor with pairs of thermoluminescent dosimeters has been calculated using the Monte Carlo code MCNP5. The response was calculated for one TLD 600 located at the center of a polyethylene cylinder, as moderator. When neutrons collide with the moderator lose their energy reaching the TLD with thermal energies where the ambient dose equivalent is calculated. The response was calculated for 47 monoenergetic neutron sources ranging from 1E(-9) to 20 MeV. Response was calculated using two irradiation geometries, one with an upper source and another with a lateral source. For both irradiation schemes the response was calculated with the TLDs in two positions, one parallel to the source and another perpendicular to the source. The advantage of this passive neutron monitor area is that can be used in locations with intense, pulsed and mixed radiation fields. (Author)

  3. Numerical analysis of the beam position monitor pickup for the Iranian light source facility

    Energy Technology Data Exchange (ETDEWEB)

    Shafiee, M., E-mail: mehdish@ipm.ir [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Feghhi, S.A.H. [Radiation Applications Department, Shahid Beheshti University, G. C., Tehran (Iran, Islamic Republic of); Rahighi, J. [Iranian Light Source Facility (ILSF), Institute for Research in Fundamental Sciences (IPM), Tehran (Iran, Islamic Republic of)

    2017-03-01

    In this paper, we describe the design of a button type Beam Position Monitor (BPM) for the low emittance storage ring of the Iranian Light Source Facility (ILSF). First, we calculate sensitivities, induced power and intrinsic resolution based on solving Laplace equation numerically by finite element method (FEM), in order to find the potential at each point of BPM's electrode surface. After the optimization of the designed BPM, trapped high order modes (HOM), wakefield and thermal loss effects are calculated. Finally, after fabrication of BPM, it is experimentally tested by using a test-stand. The results depict that the designed BPM has a linear response in the area of 2×4 mm{sup 2} inside the beam pipe and the sensitivity of 0.080 and 0.087 mm{sup −1} in horizontal and vertical directions. Experimental results also depict that they are in a good agreement with numerical analysis.

  4. The Ability to Assimilate Technology as a Source of Competitive Advantage of Financial Companies in Poland

    OpenAIRE

    Glabiszewski Waldemar; Zastempowski Maciej

    2016-01-01

    This article is empirical in nature and attempts to assess the impact of ability to assimilate newly acquired technologies by financial companies operating in Poland gaining market competitive advantages. The outcome of the research conducted proved the existence of this relationship and found it be strong. This means that the development of these abilities within the absorptive potential of financial companies should trigger a significant increase in the market competitive advantages held by...

  5. Environmental radiation monitoring of Vizag City

    International Nuclear Information System (INIS)

    Sreekanth, B.; Narsaiah, M.V.R.; Saindane, Shashank; Pujari, Raju; Krishna, N.S.; Sambamurthy, T.; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiological impact assessment is to be carried out following any radiological emergency to implement the required counter measures. A ground based environmental radiation monitoring of Vizag city has been carried out by installing various radiation monitoring instruments in a vehicle to generate the base line radiation data. It also helps to check the illicit trafficking of radioactive sources and also identifying the orphan sources. The average background radiation level observed in Vizag city was 80 nGy/h. Database of baseline radiation level with GPS location at all important locations of the whole city has been developed. No illicit trafficking of radioactive materials and orphan sources were detected during the survey. All the detectors used in the survey shown good correlation in their response. The study showed that mobile monitoring methodology will be useful in the quick assessment of radiological impact and strengthens the decision makers in reducing consequences by initiating immediate counter measures

  6. Amplifying human ability through autonomics and machine learning in IMPACT

    Science.gov (United States)

    Dzieciuch, Iryna; Reeder, John; Gutzwiller, Robert; Gustafson, Eric; Coronado, Braulio; Martinez, Luis; Croft, Bryan; Lange, Douglas S.

    2017-05-01

    Amplifying human ability for controlling complex environments featuring autonomous units can be aided by learned models of human and system performance. In developing a command and control system that allows a small number of people to control a large number of autonomous teams, we employ an autonomics framework to manage the networks that represent mission plans and the networks that are composed of human controllers and their autonomous assistants. Machine learning allows us to build models of human and system performance useful for monitoring plans and managing human attention and task loads. Machine learning also aids in the development of tactics that human supervisors can successfully monitor through the command and control system.

  7. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  8. Development of an Open Source Based Sensor Platform for an Advanced and Comprehensive in-situ DOC Monitoring

    Science.gov (United States)

    Schima, Robert; Goblirsch, Tobias; Paschen, Mathias; Rinke, Karsten; Schelwat, Heinz; Dietrich, Peter; Bumberger, Jan

    2016-04-01

    The impact of global change, intensive agriculture and complex interactions between humans and the environment show different effects on different scales. However, the desire to obtain a better understanding of ecosystems and process dynamics in nature accentuates the need for observing these processes in higher temporal and spatial resolutions. Especially with regard to the process dynamics and heterogeneity of water catchment areas, a comprehensive monitoring of the ongoing processes and effects remains to be a challenging issue in the field of applied environmental research. Moreover, harsh conditions and a variety of influencing process parameters are representing a particular challenge due to an adaptive in-situ monitoring of vast areas. Today, open source based electronics and cost-effective sensors and sensor components are offering a promising approach to investigate new possibilities of smart phone based mobile data acquisition and comprehensive ad-hoc monitoring of environmental processes. Accordingly, our project aims the development of new strategies for mobile data acquisition and real-time processing of user-specific environmental data, based on a holistic and integrated process. To this end, the concept of our monitoring system covers the data collection, data processing and data integration as well as the data provision within one infrastructure. The whole monitoring system consists of several mobile sensor devices, a smart phone app (Android) and a web service for data processing, data provision and data visualization. The smart phone app allows the configuration of the mobile sensor device and provides some built-in functions such as data visualization or data transmission via e-mail. Besides the measurement of temperature and humidity in air, the mobile sensor device is able to acquire sensor readings for the content of dissolved organic compounds (λ = 254 nm) and turbidity (λ = 860 nm) of surface water based on the developed optical in

  9. Proceedings of the 29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Wetovsky, Marvin A. [Editor; Benson, Jody [Editor; Patterson, Eileen F. [Editor

    2007-09-25

    These proceedings contain papers prepared for the 29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies, held 25-27 September, 2007 in Denver, Colorado. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Technical Applications Center (AFTAC), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  10. Proceedings of the 29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

    International Nuclear Information System (INIS)

    Wetovsky, Marvin A.; Benson, Jody; Patterson, Eileen F.

    2007-01-01

    These proceedings contain papers prepared for the 29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies, held 25-27 September, 2007 in Denver, Colorado. These papers represent the combined research related to ground-based nuclear explosion monitoring funded by the National Nuclear Security Administration (NNSA), Air Force Technical Applications Center (AFTAC), Air Force Research Laboratory (AFRL), US Army Space and Missile Defense Command, Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), and other invited sponsors. The scientific objectives of the research are to improve the United States capability to detect, locate, and identify nuclear explosions. The purpose of the meeting is to provide the sponsoring agencies, as well as potential users, an opportunity to review research accomplished during the preceding year and to discuss areas of investigation for the coming year. For the researchers, it provides a forum for the exchange of scientific information toward achieving program goals, and an opportunity to discuss results and future plans. Paper topics include: seismic regionalization and calibration; detection and location of sources; wave propagation from source to receiver; the nature of seismic sources, including mining practices; hydroacoustic, infrasound, and radionuclide methods; on-site inspection; and data processing.

  11. Monitoring and Analysis of Nonpoint Source Pollution - Case study on terraced paddy fields in an agricultural watershed

    Science.gov (United States)

    Chen, Shih-Kai; Jang, Cheng-Shin; Yeh, Chun-Lin

    2013-04-01

    The intensive use of chemical fertilizer has negatively impacted environments in recent decades, mainly through water pollution by nitrogen (N) and phosphate (P) originating from agricultural activities. As a main crop with the largest cultivation area about 0.25 million ha per year in Taiwan, rice paddies account for a significant share of fertilizer consumption among agriculture crops. This study evaluated the fertilization of paddy fields impacting return flow water quality in an agricultural watershed located at Hsinchu County, northern Taiwan. Water quality monitoring continued for two crop-periods in 2012, around subject to different water bodies, including the irrigation water, drainage water, and shallow groundwater. The results indicated that obviously increasing of ammonium-N, nitrate-N and TP concentrations in the surface drainage water were observed immediately following three times of fertilizer applications (including basal, tillering, and panicle fertilizer application), but reduced to relatively low concentrations after 7-10 days after each fertilizer application. Groundwater quality monitoring showed that the observation wells with the more shallow water depth, the more significant variation of concentrations of ammonium-N, nitrate-N and TP could be observed, which means that the contamination potential of nutrient of groundwater is related not only to the impermeable plow sole layer but also to the length of percolation route in this area. The study also showed that the potential pollution load of nutrient could be further reduced by well drainage water control and rational fertilizer management, such as deep-water irrigation, reuse of return flow, the rational application of fertilizers, and the SRI (The System of Rice Intensification) method. The results of this study can provide as an evaluation basis to formulate effective measures for agricultural non-point source pollution control and the reuse of agricultural return flow. Keywords

  12. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Newcomer, D.R.; Thornton, E.C.; Hartman, M.J.; Dresel, P.E.

    1999-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954 the Resource Conservation and Recovery Act of 1976 the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The US Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/frequency matrix for the entire site. The objectives of monitoring fall into three general categories plume and trend tracking, treatment/storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  13. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  14. Monitoring the Carbon Cycle: Improving Our Ability to Proved Policy Relevant Information

    Science.gov (United States)

    Bruhwiler, L.

    2017-12-01

    Humans have altered the energy balance of the climate system mainly by producing and consuming fossil fuels, but also by emissions from food production. Manufacture and use of halocarbons, many of which are also strong greenhouse gases (GHGs) have added to anthropogenic radiative forcing. In response, the global atmosphere has warmed over the last half century at a rate of 0.17°C. The largest contribution to radiative forcing is due to CO2, and at present, about half of all anthropogenic CO2 emissions have been taken up by the oceans and terrestrial biosphere. The size of this "carbon emission discount" may change in the future as more carbon accumulates in the oceans, as human alter landscapes, and as climate changes. Efforts to limit global average temperature increases to 2°C and avoid the most catastrophic consequences of climate change depend on keeping track of both human emissions of greenhouse gases and changes in natural fluxes of carbon and nitrogen that occur in response to human activities and changing climate. Global in situ network observations provide information about changes in global GHG abundances over recent decades, as well as changing distributions between hemispheres. This information gives insight into changes in global and hemispheric sources and sinks of GHGs. It is, however, currently difficult to obtain robust information about regional sources and to discriminate between natural and anthropogenic fluxes. Information about regional sources is needed for GHG policymaking, while discrimination of natural sources is necessary for detection of trends in GHG fluxes and evaluation of coupled carbon cycle climate models. Although column average GHG abundances from space-based remote sensing data could provide considerable constraints on GHG budgets, there are still technical challenges to be overcome. Possible strategies for making progress involve greater increased observational coverage and more international collaboration, as well as

  15. Monitoring of seismic events from a specific source region using a single regional array: A case study

    Science.gov (United States)

    Gibbons, S. J.; Kværna, T.; Ringdal, F.

    2005-07-01

    In the monitoring of earthquakes and nuclear explosions using a sparse worldwide network of seismic stations, it is frequently necessary to make reliable location estimates using a single seismic array. It is also desirable to screen out routine industrial explosions automatically in order that analyst resources are not wasted upon detections which can, with a high level of confidence, be associated with such a source. The Kovdor mine on the Kola Peninsula of NW Russia is the site of frequent industrial blasts which are well recorded by the ARCES regional seismic array at a distance of approximately 300 km. We describe here an automatic procedure for identifying signals which are likely to result from blasts at the Kovdor mine and, wherever possible, for obtaining single array locations for such events. Carefully calibrated processing parameters were chosen using measurements from confirmed events at the mine over a one-year period for which the operators supplied Ground Truth information. Phase arrival times are estimated using an autoregressive method and slowness and azimuth are estimated using broadband f{-} k analysis in fixed frequency bands and time-windows fixed relative to the initial P-onset time. We demonstrate the improvement to slowness estimates resulting from the use of fixed frequency bands. Events can be located using a single array if, in addition to the P-phase, at least one secondary phase is found with both an acceptable slowness estimate and valid onset-time estimate. We evaluate the on-line system over a twelve month period; every event known to have occured at the mine is detected by the process and 32 out of 53 confirmed events were located automatically. The remaining events were classified as “very likely” Kovdor events and were subsequently located by an analyst. The false alarm rate is low; only 84 very likely Kovdor events were identified during the whole of 2003 and none of these were subsequently located at a large distance from

  16. Persulfate injection into a gasoline source zone

    Science.gov (United States)

    Sra, Kanwartej S.; Thomson, Neil R.; Barker, Jim F.

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O82 -, SO42 -, Na+, dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for > 10 months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in M indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M increased by > 100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone.

  17. Orphan sources control in the Republic of Korea

    International Nuclear Information System (INIS)

    Kim, C.-W.

    2001-01-01

    In this paper, the orphan source control programme in Korea will be discussed. Orphan sources are, in general, classified into three groups: 1) Illegally trafficking radioactive sources; 2) Domestic loss of radioactive sources due to the bankruptcy of licensees or authorized suppliers; and 3) Contaminated metal scrap, which has been imported. There are, currently, two approaches going on to control and manage orphan sources in Korea. First, the Korean regulatory authority (Ministry of Science and Technology: MOST) will fully run an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the year 2001. Second, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect scrap metal through a scrap monitoring system when they attempt to reutilize it in order to prevent it from being contaminated by uncontrolled sources. The Korea Institute of Nuclear Safety (KINS), a regulatory expert organization, is carrying out a three-year multiphase project to control and monitor orphan sources in Korea. The system, called the Information System on Integrated Radiation Safety (ISIRS) on the inter- and intra-net system has been developed to effectively control and accurately monitor radioactive sources on a real time basis since 1998. If the system is successfully set up as scheduled by the middle of May next year, the regulatory authority will be able to control any reutilization of uncontrolled sources efficiently. At the same time, the system can also provide, not only licensees, suppliers, or perspective end users but also the Korean general public of interests with information on radiation safety, safe radiation management tools and public services. The system has been created because of the necessity to effectively control radioactive sources safely. Also, it serves to prepare necessary protective measures in a timely manner for abnormal events of uncontrolled radiation from

  18. Material monitoring

    International Nuclear Information System (INIS)

    Kotter, W.; Zirker, L.; Hancock, J.A.

    1995-01-01

    Waste Reduction Operations Complex (WROC) facilities are located at the Idaho National Engineering Laboratory (INEL). The overall goal for the Pollution Prevention/Waste Minimization Unit is to identify and establish the correct amount of waste generated so that it can be reduced. Quarterly, the INEL Pollution Prevention (P2) Unit compares the projected amount of waste generated per process with the actual amount generated. Examples of waste streams that would be addresses for our facility would include be are not limited to: Maintenance, Upgrades, Office and Scrap Metal. There are three potential sources of this variance: inaccurate identification of those who generate the waste; inaccurate identification of the process that generates the waste; and inaccurate measurement of the actual amount generated. The Materials Monitoring Program was proposed to identify the sources of variance and reduce the variance to an acceptable level. Prior to the implementation of the Material Monitoring Program, all information that was gathered and recorded was done so through an informal estimation of waste generated by various personnel concerned with each processes. Due to the inaccuracy of the prior information gathering system, the Material Monitoring Program was established. The heart of this program consists of two main parts. In the first part potential waste generators provide information on projected waste generation process. In the second part, Maintenance, Office, Scrap Metal and Facility Upgrade wastes from given processes is disposed within the appropriate bin dedicated to that process. The Material Monitoring Program allows for the more accurate gathering of information on the various waste types that are being generated quarterly

  19. Prototype photon position monitors for undulator beams at the advanced light source

    International Nuclear Information System (INIS)

    Warwick, T.; Shu, D.; Rodricks, B.; Johnson, E.D.

    1992-01-01

    Design criteria are described, and test results are presented, for prototype ALS undulator beam position monitors. The design is based on monitors presently in use at NSLS, with modifications to account for the widely varying and large K values of the undulators to be installed at the ALS. In particular, we have modified the design to simplify the thermal engineering and we have explored techniques to suppress the response of the monitors to soft photons, so that the beam position can be determined by measuring the higher energy photons which are better collimated

  20. Wireless air monitoring network with new AMIZ-2004G dust monitors

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Machaj, B.; Pienkos, P.; Swistowski, E.

    2006-01-01

    The principle of operation of the dust monitors is based on determination of dust mass deposited on air filters from known volumes of air samples. The dust mass is determined from radiation attenuation of a Pm-147 beta source. MIZA and AMIZ monitors produced in the Institute of Nuclear Chemistry and Technology, Warsaw (Poland) additionally measure relative humidity, atmospheric pressure and temperature of the air. In case the measurements are made in a few different places, direct collection of the results requires that personnel of the environment protection units has to go frequently to the monitors and collect the data. To improve the data transmission, a new version of the AMIZ-2004G monitor was developed which is equipped with a GSM modem enabling communication with a central computer. Thanks to the new construction not only a remote wireless communication with AMIZ is possible, but also a monitoring network containing a higher number of dust monitors can be made. The measuring data from all the monitors in the network can now be collected in one central computer equipped with the GSM modem and a proper acquisition program. In 2005, two such monitoring networks were put into operation

  1. Age-Related Differences in Multiple Task Monitoring

    OpenAIRE

    Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo

    2014-01-01

    Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men excee...

  2. Improved Marine Waters Monitoring

    Science.gov (United States)

    Palazov, Atanas; Yakushev, Evgeniy; Milkova, Tanya; Slabakova, Violeta; Hristova, Ognyana

    2017-04-01

    IMAMO - Improved Marine Waters Monitoring is a project under the Programme BG02: Improved monitoring of marine waters, managed by Bulgarian Ministry of environment and waters and co-financed by the Financial Mechanism of the European Economic Area (EEA FM) 2009 - 2014. Project Beneficiary is the Institute of oceanology - Bulgarian Academy of Sciences with two partners: Norwegian Institute for Water Research and Bulgarian Black Sea Basin Directorate. The Project aims to improve the monitoring capacity and expertise of the organizations responsible for marine waters monitoring in Bulgaria to meet the requirements of EU and national legislation. The main outcomes are to fill the gaps in information from the Initial assessment of the marine environment and to collect data to assess the current ecological status of marine waters including information as a base for revision of ecological targets established by the monitoring programme prepared in 2014 under Art. 11 of MSFD. Project activities are targeted to ensure data for Descriptors 5, 8 and 9. IMAMO aims to increase the institutional capacity of the Bulgarian partners related to the monitoring and assessment of the Black Sea environment. The main outputs are: establishment of real time monitoring and set up of accredited laboratory facilities for marine waters and sediments chemical analysis to ensure the ability of Bulgarian partners to monitor progress of subsequent measures undertaken.

  3. Structure function monitor

    Science.gov (United States)

    McGraw, John T [Placitas, NM; Zimmer, Peter C [Albuquerque, NM; Ackermann, Mark R [Albuquerque, NM

    2012-01-24

    Methods and apparatus for a structure function monitor provide for generation of parameters characterizing a refractive medium. In an embodiment, a structure function monitor acquires images of a pupil plane and an image plane and, from these images, retrieves the phase over an aperture, unwraps the retrieved phase, and analyzes the unwrapped retrieved phase. In an embodiment, analysis yields atmospheric parameters measured at spatial scales from zero to the diameter of a telescope used to collect light from a source.

  4. Imaging Stress Transients and Fault Zone Processes with Crosswell Continuous Active-Source Seismic Monitoring at the San Andreas Fault Observatory at Depth

    Science.gov (United States)

    Niu, F.; Taira, T.; Daley, T. M.; Marchesini, P.; Robertson, M.; Wood, T.

    2017-12-01

    Recent field and laboratory experiments identify seismic velocity changes preceding microearthquakes and rock failure (Niu et al., 2008, Nature; Scuderi et al., 2016, NatureGeo), which indicates that a continuous monitoring of seismic velocity might provide a mean of understanding of the earthquake nucleation process. Crosswell Continuous Active-Source Seismic Monitoring (CASSM) using borehole sources and sensors has proven to be an effective tool for measurements of seismic velocity and its temporal variation at seismogenic depth (Silver, et al, 2007, BSSA; Daley, et al, 2007, Geophysics). To expand current efforts on the CASSM development, in June 2017 we have begun to conduct a year-long CASSM field experiment at the San Andreas Fault Observatory at Depth (SAFOD) in which the preceding field experiment detected the two sudden velocity reductions approximately 10 and 2 hours before microearthquakes (Niu et al., 2008, Nature). We installed a piezoelectric source and a three-component accelerometer at the SAFOD pilot and main holes ( 1 km depth) respectively. A seismic pulse was fired from the piezoelectric source four times per second. Each waveform was recorded 150-ms-long data with a sampling rate of 48 kHz. During this one-year experiment, we expect to have 10-15 microearthquakes (magnitude 1-3) occurring near the SAFOD site, and the data collected from the new experiment would allow us to further explore a relation between velocity changes and the Parkfield seismicity. Additionally, the year-long data provide a unique opportunity to study long-term velocity changes that might be related to seasonal stress variations at Parkfield (Johnson et al., 2017, Science). We will report on initial results of the SAFOD CASSM experiment and operational experiences of the CASSM development.

  5. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    International Nuclear Information System (INIS)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-01-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L"−"1). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ"1"8O, δ"1"5N and δ"3"4S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L"−"1. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ"1"5N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with

  6. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    Energy Technology Data Exchange (ETDEWEB)

    Estevez, Esmeralda, E-mail: eestevez@proyinves.ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Cabrera, María del Carmen, E-mail: mcarmen.cabrera@ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); IMDEA Water Institute, Alcalá de Henares, Madrid (Spain); Fernández-Vera, Juan Ramón, E-mail: jrfernandezv@grancanaria.com [Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Molina-Díaz, Antonio, E-mail: amolina@ujaen.es [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Robles-Molina, José, E-mail: jroblesmol@gmail.com [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Palacios-Díaz, María del Pino, E-mail: mp.palaciosdiaz@ulpgc.es [Dpt. de Patología Animal, Producción Animal, Bromatología y Tecnología de los Alimentos (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35413 Arucas, Canary Islands (Spain)

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L{sup −1}). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ{sup 18}O, δ{sup 15}N and δ{sup 34}S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L{sup −1}. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ{sup 15}N and the lowest contaminants occurrence. The area is an example of a complex

  7. Use of remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fournel, E; Gouilloux, C

    1977-01-01

    Paper traces the development of remote monitoring devices, since their first appearance for safety purposes. Discusses their uses in coal mines: working and safety (definitions); sources and channels of information (transmission of information by automatic or verbal means); mine control stations; duties and responsibilities of persons in charge. Examines the contribution made by remote monitoring to management in production sector. Gives examples of assistance given to production management showing a very advantageous result on balance, by their use. The use of computers in real time and in batched mode is compared. Discusses their use in monitoring mine atmosphere. Very favorable results have already been obtained in France and abroad. The broadening scope and future of remote monitoring is considered.

  8. External Monitoring and Dynamic Behavior in Mutual Funds

    Directory of Open Access Journals (Sweden)

    Jian Wang

    2016-01-01

    Full Text Available This paper studies the impact of external monitoring on the behavior in mutual funds. Specifically, we investigate how and why external monitoring can alleviate contracting inefficiency caused by information asymmetry between investors and the manager. It is shown that efficiency loss emerges when investors contract with the manager just relying on her investment return history. The establishment of external monitoring that provides investors more information about the manager’s ability can improve contracting efficiency, which converges to first-best as external monitoring strengthens. These results provide strong support for tightening supervision in mutual fund industry.

  9. The influence of Missouri mathematics project on seventh grade students’ mathematical understanding ability

    Science.gov (United States)

    Rezeki, S.; Setyawan, A. A.; Amelia, S.

    2018-01-01

    Mathematical understanding ability is a primary goal of Indonesian national education goals. However, various sources has shown that Indonesian students’ mathematical understanding ability is still relatively low. This study used quasi-experimental research design to examine the effectiveness of the application of Missouri Mathematics Project (MMP) on students’ mathematical understanding ability. The participants of the study were seventh grade students in Pekanbaru, Riau Province, Indonesia. They were selected purposively and represented as high, medium, and low-quality schools. The result of this study indicated that there was a significant effect of MMP on the overall students’ mathematical understanding ability and in all categories, except for low school level.

  10. Study on intermediate frequency power supply automatic monitor system

    International Nuclear Information System (INIS)

    Wang Yuntong; Xu Bin

    2007-06-01

    A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)

  11. Optimizing study design for multi-species avian monitoring programmes

    Science.gov (United States)

    Jamie S. Sanderlin; William M. Block; Joseph L. Ganey

    2014-01-01

    Many monitoring programmes are successful at monitoring common species, whereas rare species, which are often of highest conservation concern, may be detected infrequently. Study designs that increase the probability of detecting rare species at least once over the study period, while collecting adequate data on common species, strengthen programme ability to address...

  12. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  13. Environmental monitoring of low-level radioactive materials

    International Nuclear Information System (INIS)

    Jester, W.A.; Yu, C.

    1985-01-01

    The authors discuss some of the current rationale behind the environmental monitoring of low-level radioactive materials are as follows: Committee 4 of the International commission on Radiological Protection (ICRP) defined three broad objectives for environmental monitoring: 1) assessment of the actual or potential exposure of humans to radioactive materials or radiation present in their environment or the estimation of the probable upper limits of such exposure; 2) scientific investigation, sometimes related to the assessment of exposures, sometimes to other objectives; 3) improved public relations. Various regulations have been written requiring environmental monitoring to ensure that the public is not being exposed to excessive amounts of radiation from natural sources or from human activities. An example of the monitoring of natural sources of radiation is a requirement of the Environmental Protection Agency's (EPA) National Interim Primary Drinking Water Regulations whereby U.S. water supply companies must have drinking water monitored at least once every four years for radionuclides, primarily the naturally occurring radium-226

  14. Tuning permissiveness of active safety monitors for autonomous systems

    OpenAIRE

    Masson , Lola; Guiochet , Jérémie; Waeselynck , Hélène; Cabrera , Kalou; Cassel , Sofia; Törngren , Martin

    2018-01-01

    International audience; Robots and autonomous systems have become a part of our everyday life, therefore guaranteeing their safety is crucial.Among the possible ways to do so, monitoring is widely used, but few methods exist to systematically generate safety rules to implement such monitors. Particularly, building safety monitors that do not constrain excessively the system's ability to perform its tasks is necessary as those systems operate with few human interventions.We propose in this pap...

  15. Model predictive control for Z-source power converter

    DEFF Research Database (Denmark)

    Mo, W.; Loh, P.C.; Blaabjerg, Frede

    2011-01-01

    This paper presents Model Predictive Control (MPC) of impedance-source (commonly known as Z-source) power converter. Output voltage control and current control for Z-source inverter are analyzed and simulated. With MPC's ability of multi- system variables regulation, load current and voltage...

  16. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Hartman, Mary J.; Dresel, P. Evan; Lindberg, Jon W.; Newcomer, Darrell R.; Thornton, Edward C.

    2000-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954; the Resource Conservation and Recovery Act of 1976; the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The U.S. Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/ frequency matrix for the entire site. The objectives of monitoring fall into three general categories: plume and trend tracking, treatment/ storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  17. Tutorial on beam current monitoring

    International Nuclear Information System (INIS)

    Webber, Robert C.

    2000-01-01

    This paper is a tutorial level review covering a wide range of aspects related to charged particle beam current measurement. The tutorial begins with a look at the characteristics of the beam as a signal source, the associated electromagnetic fields, the influence of the typical accelerator environment on those fields, and the usual means of modifying and controlling that environment to facilitate beam current measurement. Short descriptions of three quite different types of current monitors are presented and a quantitative review of the classical transformer circuit is given. Recognizing that environmental noise pick-up may present a large source of error in quantitative measurements, signal handling considerations are given considerable attention using real-life examples. An example of a successful transport line beam current monitor implementation is presented and the tutorial concludes with a few comments about signal processing and current monitor calibration issues

  18. Backup power sources for DOE facilities

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    This standard establishes fundamental requirements and guidance for backup power sources at DOE facilities. Purpose is to document good engineering practices for installation, testing, and maintenance of these backup power sources, which also covers emergency power sources. Examples are those which supply power to nuclear safety systems, radiation monitors and alarms, fire protection systems, security systems, and emergency lighting.

  19. Source apportionment of hydrocarbons measured in the Eagle Ford shale

    Science.gov (United States)

    Roest, G. S.; Schade, G. W.

    2016-12-01

    The rapid development of unconventional oil and gas in the US has led to hydrocarbon emissions that are yet to be accurately quantified. Emissions from the Eagle Ford Shale in southern Texas, one of the most productive shale plays in the U.S., have received little attention due to a sparse air quality monitoring network, thereby limiting studies of air quality within the region. We use hourly atmospheric hydrocarbon and meteorological data from three locations in the Eagle Ford Shale to assess their sources. Data are available from the Texas commission of environmental quality (TCEQ) air quality monitors in Floresville, a small town southeast of San Antonio and just north of the shale area; and Karnes city, a midsize rural city in the center of the shale. Our own measurements were carried out at a private ranch in rural Dimmit County in southern Texas from April to November of 2015. Air quality monitor data from the TCEQ were selected for the same time period. Non-negative matrix factorization in R (package NMF) was used to determine likely sources and their contributions above background. While the TCEQ monitor data consisted mostly of hydrocarbons, our own data include both CO, CO2, O3, and NOx. We find that rural Dimmit County hydrocarbons are dominated by oil and gas development sources, while central shale hydrocarbons at the TCEQ monitoring sites have a mix of sources including car traffic. However, oil and gas sources also dominate hydrocarbons at Floresville and Karnes City. Toxic benzene is nearly exclusively due to oil and gas development sources, including flaring, which NMF identifies as a major hydrocarbon source in Karnes City. Other major sources include emissions of light weight alkanes (C2-C5) from raw natural gas emissions and a larger set of alkanes (C2-C10) from oil sources, including liquid storage tanks.

  20. The WATCH All-Sky Monitor for the Granat Project

    DEFF Research Database (Denmark)

    Brandt, Søren; Lund, Niels; Rao, A. R.

    1990-01-01

    The Watch X-ray all-sky monitor, which is designed to localize strong X-ray sources and follow their development, is examined, focusing on the addition of four Watch units to the Granat satellite project. The components of the Watch instrument are described and the capabilities and potential...... scientific returns of the Granat project are discussed. The applications of the Watch monitor are given, including the study of time variations of known sources and the detection and localization of new, transient sources....

  1. Scientific Opportunities for Monitoring at Environmental Remediation Sites (SOMERS): Integrated Systems-Based Approaches to Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bunn, Amoret L.; Wellman, Dawn M.; Deeb, Rula A.; Hawley, Elizabeth L.; Truex, Michael J.; Peterson, Mark; Freshley, Mark D.; Pierce, Eric M.; McCord, John; Young, Michael H.; Gilmore, Tyler J.; Miller, Rick; Miracle, Ann L.; Kaback, Dawn; Eddy-Dilek, Carol; Rossabi, Joe; Lee, Michelle H.; Bush, Richard P.; Beam , Paul; Chamberlain, G. M.; Marble, Justin; Whitehurst, Latrincy; Gerdes, Kurt D.; Collazo, Yvette

    2012-05-15

    Through an inter-disciplinary effort, DOE is addressing a need to advance monitoring approaches from sole reliance on cost- and labor-intensive point-source monitoring to integrated systems-based approaches such as flux-based approaches and the use of early indicator parameters. Key objectives include identifying current scientific, technical and implementation opportunities and challenges, prioritizing science and technology strategies to meet current needs within the DOE complex for the most challenging environments, and developing an integrated and risk-informed monitoring framework.

  2. Calibration device for wide range monitor

    International Nuclear Information System (INIS)

    Kodoku, Masaya; Sato, Toshifumi.

    1989-01-01

    The calibration device for a wide range monitor according to the present invention can continuously calibrate the entire counting regions of a wide range monitor. The wide range monitor detect the reactor power in the neutron source region by means of a pulse counting method and detects the reactor power in the intermediate region by means of a cambell method. A calibration signal outputting means is disposed for continuously outputting, as such calibration signals, pulse number varying signals in which the number of pulses per unit time varies depending on the reactor power in the neutron source region to be simulated and amplitude square means varying signal in which the mean square value of amplitude varies depending on the reactor power in the intermediate region to be simulated. By using both of the calibration signals, calibration can be conducted for the nuclear reactor power in the neutron source region and the intermediate region even if the calibration is made over two regions, further, calibration for the period present over the two region can be conducted easily as well. (I.S.)

  3. Persulfate injection into a gasoline source zone.

    Science.gov (United States)

    Sra, Kanwartej S; Thomson, Neil R; Barker, Jim F

    2013-07-01

    One pore volume of unactivated sodium persulfate was delivered into an emplaced gasoline residual source zone at CFB Borden. Concentrations of inorganic species (S2O8(2-), SO4(2-), Na(+), dissolved inorganic carbon (DIC)) and selected gasoline compounds (benzene, toluene, ethylbenzene, xylenes, trimethylbenzenes and naphthalene) were monitored across a transect equipped with 90 multilevel sampling points for >10months post-injection. Mass loading (M˙) of compounds constructed from the transect data was used for assessment purposes. Breakthrough of inorganic species was observed when the injection slug crossed the monitoring transect. An increase in [Formula: see text] indicated persulfate consumption during oxidation of gasoline compounds or degradation due to the interaction with aquifer materials. M˙DIC increased by >100% suggesting some mineralization of gasoline compounds during treatment. Mass loading for all the monitored gasoline compounds reduced by 46 to 86% as the inorganic slug crossed the monitoring transect. The cumulative mass discharge across the monitoring transect was 19 to 58% lower than that expected without persulfate injection. After the inorganic injection slug was flushed from the source zone a partial rebound (40 to 80% of baseline levels) of mass discharge of the monitored gasoline compounds was observed. The ensemble of data collected provides insight into the fate and transport of the injected persulfate solution, and the accompanying treatment of a gasoline the source zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Open source software and libraries

    OpenAIRE

    Randhawa, Sukhwinder

    2008-01-01

    Open source software is, software that users have the ability to run, copy, distribute, study, change, share and improve for any purpose. Open source library software’s does not need the initial cost of commercial software and enables libraries to have greater control over their working environment. Library professionals should be aware of the advantages of open source software and should involve in their development. They should have basic knowledge about the selection, installation and main...

  5. Monitor Clean and Efficient. Background information. Methods and references as applied in the Monitor in April 2009

    International Nuclear Information System (INIS)

    Gerdes, J.; De Ligt, T.

    2010-01-01

    This report contains background information about the Monitor Clean and Efficient that was published in April 2009. The goal and approach of the Monitor are clarified, as well as the methods and data that are used. The structure of this report resembles the structure of the Monitor. Sources and dates of availability are mentioned along with the data, as are the parties collecting and processing the information. The results that were found using this methodology have been published in the Monitor Clean and Efficient. [nl

  6. Synthesis of juvenile lamprey migration and passage research and monitoring at Columbia and Snake River Dams

    Science.gov (United States)

    Mesa, Matthew G.; Weiland, Lisa K.; Christiansen, Helena E.

    2016-01-01

    We compiled and summarized previous sources of data and research results related to the presence, numbers, and migration timing characteristics of juvenile (eyed macropthalmia) and larval (ammocoetes) Pacific lamprey Entosphenus tridentatus, in the Columbia River basin (CRB). Included were data from various screw trap collections, data from historic fyke net studies, catch records of lampreys at JBS facilities, turbine cooling water strainer collections, and information on the occurrence of lampreys in the diets of avian and piscine predators. We identified key data gaps and uncertainties that should be addressed in a juvenile lamprey passage research program. The goal of this work was to summarize information from disparate sources so that managers can use it to prioritize and guide future research and monitoring efforts related to the downstream migration of juvenile Pacific lamprey within the CRB. A common finding in all datasets was the high level of variation observed for CRB lamprey in numbers present, timing and spatial distribution. This will make developing monitoring programs to accurately characterize lamprey migrations and passage more challenging. Primary data gaps centered around our uncertainty on the numbers of juvenile and larval present in the system which affects the ability to assign risk to passage conditions and prioritize management actions. Recommendations include developing standardized monitoring methods, such as at juvenile bypass systems (JBS’s), to better document numbers and timing of lamprey migrations at dams, and use biotelemetry tracking techniques to estimate survival potentials for different migration histories.

  7. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    Hinkson, J.

    1993-10-01

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  8. An autonomous structural health monitoring solution

    Science.gov (United States)

    Featherston, Carol A.; Holford, Karen M.; Pullin, Rhys; Lees, Jonathan; Eaton, Mark; Pearson, Matthew

    2013-05-01

    Combining advanced sensor technologies, with optimised data acquisition and diagnostic and prognostic capability, structural health monitoring (SHM) systems provide real-time assessment of the integrity of bridges, buildings, aircraft, wind turbines, oil pipelines and ships, leading to improved safety and reliability and reduced inspection and maintenance costs. The implementation of power harvesting, using energy scavenged from ambient sources such as thermal gradients and sources of vibration in conjunction with wireless transmission enables truly autonomous systems, reducing the need for batteries and associated maintenance in often inaccessible locations, alongside bulky and expensive wiring looms. The design and implementation of such a system however presents numerous challenges. A suitable energy source or multiple sources capable of meeting the power requirements of the system, over the entire monitoring period, in a location close to the sensor must be identified. Efficient power management techniques must be used to condition the power and deliver it, as required, to enable appropriate measurements to be taken. Energy storage may be necessary, to match a continuously changing supply and demand for a range of different monitoring states including sleep, record and transmit. An appropriate monitoring technique, capable of detecting, locating and characterising damage and delivering reliable information, whilst minimising power consumption, must be selected. Finally a wireless protocol capable of transmitting the levels of information generated at the rate needed in the required operating environment must be chosen. This paper considers solutions to some of these challenges, and in particular examines SHM in the context of the aircraft environment.

  9. Realtime Gas Emission Monitoring at Hazardous Sites Using a Distributed Point-Source Sensing Infrastructure

    Directory of Open Access Journals (Sweden)

    Gianfranco Manes

    2016-01-01

    Full Text Available This paper describes a distributed point-source monitoring platform for gas level and leakage detection in hazardous environments. The platform, based on a wireless sensor network (WSN architecture, is organised into sub-networks to be positioned in the plant’s critical areas; each sub-net includes a gateway unit wirelessly connected to the WSN nodes, hence providing an easily deployable, stand-alone infrastructure featuring a high degree of scalability and reconfigurability. Furthermore, the system provides automated calibration routines which can be accomplished by non-specialized maintenance operators without system reliability reduction issues. Internet connectivity is provided via TCP/IP over GPRS (Internet standard protocols over mobile networks gateways at a one-minute sampling rate. Environmental and process data are forwarded to a remote server and made available to authenticated users through a user interface that provides data rendering in various formats and multi-sensor data fusion. The platform is able to provide real-time plant management with an effective; accurate tool for immediate warning in case of critical events.

  10. Realtime Gas Emission Monitoring at Hazardous Sites Using a Distributed Point-Source Sensing Infrastructure

    Science.gov (United States)

    Manes, Gianfranco; Collodi, Giovanni; Gelpi, Leonardo; Fusco, Rosanna; Ricci, Giuseppe; Manes, Antonio; Passafiume, Marco

    2016-01-01

    This paper describes a distributed point-source monitoring platform for gas level and leakage detection in hazardous environments. The platform, based on a wireless sensor network (WSN) architecture, is organised into sub-networks to be positioned in the plant’s critical areas; each sub-net includes a gateway unit wirelessly connected to the WSN nodes, hence providing an easily deployable, stand-alone infrastructure featuring a high degree of scalability and reconfigurability. Furthermore, the system provides automated calibration routines which can be accomplished by non-specialized maintenance operators without system reliability reduction issues. Internet connectivity is provided via TCP/IP over GPRS (Internet standard protocols over mobile networks) gateways at a one-minute sampling rate. Environmental and process data are forwarded to a remote server and made available to authenticated users through a user interface that provides data rendering in various formats and multi-sensor data fusion. The platform is able to provide real-time plant management with an effective; accurate tool for immediate warning in case of critical events. PMID:26805832

  11. Realtime Gas Emission Monitoring at Hazardous Sites Using a Distributed Point-Source Sensing Infrastructure.

    Science.gov (United States)

    Manes, Gianfranco; Collodi, Giovanni; Gelpi, Leonardo; Fusco, Rosanna; Ricci, Giuseppe; Manes, Antonio; Passafiume, Marco

    2016-01-20

    This paper describes a distributed point-source monitoring platform for gas level and leakage detection in hazardous environments. The platform, based on a wireless sensor network (WSN) architecture, is organised into sub-networks to be positioned in the plant's critical areas; each sub-net includes a gateway unit wirelessly connected to the WSN nodes, hence providing an easily deployable, stand-alone infrastructure featuring a high degree of scalability and reconfigurability. Furthermore, the system provides automated calibration routines which can be accomplished by non-specialized maintenance operators without system reliability reduction issues. Internet connectivity is provided via TCP/IP over GPRS (Internet standard protocols over mobile networks) gateways at a one-minute sampling rate. Environmental and process data are forwarded to a remote server and made available to authenticated users through a user interface that provides data rendering in various formats and multi-sensor data fusion. The platform is able to provide real-time plant management with an effective; accurate tool for immediate warning in case of critical events.

  12. Summary of Numerical Modeling for Underground Nuclear Test Monitoring Symposium

    International Nuclear Information System (INIS)

    Taylor, S.R.; Kamm, J.R.

    1993-01-01

    This document contains the Proceedings of the Numerical Modeling for Underground Nuclear Test Monitoring Symposium held in Durango, Colorado on March 23-25, 1993. The symposium was sponsored by the Office of Arms Control and Nonproliferation of the United States Department of Energy and hosted by the Source Region Program of Los Alamos National Laboratory. The purpose of the meeting was to discuss state-of-the-art advances in numerical simulations of nuclear explosion phenomenology for the purpose of test ban monitoring. Another goal of the symposium was to promote discussion between seismologists and explosion source-code calculators. Presentation topics include the following: numerical model fits to data, measurement and characterization of material response models, applications of modeling to monitoring problems, explosion source phenomenology, numerical simulations and seismic sources

  13. Ability to Work among Patients with ESKD: Relevance of Quality Care Metrics.

    Science.gov (United States)

    Kutner, Nancy G; Zhang, Rebecca

    2017-08-07

    Enabling patient ability to work was a key rationale for enacting the United States (US) Medicare program that provides financial entitlement to renal replacement therapy for persons with end-stage kidney disease (ESKD). However, fewer than half of working-age individuals in the US report the ability to work after starting maintenance hemodialysis (HD). Quality improvement is a well-established objective in oversight of the dialysis program, but a more patient-centered quality assessment approach is increasingly advocated. The ESKD Quality Incentive Program (QIP) initiated in 2012 emphasizes clinical performance indicators, but a newly-added measure requires the monitoring of patient depression-an issue that is important for work ability and employment. We investigated depression scores and four dialysis-specific QIP measures in relation to work ability reported by a multi-clinic cohort of 528 working-age maintenance HD patients. The prevalence of elevated depression scores was substantially higher among patients who said they were not able to work, while only one of the four dialysis-specific clinical measures differed for patients able/not able to work. Ability to work may be among patients' top priorities. As the parameters of quality assessment continue to evolve, increased attention to patient priorities might facilitate work ability and employment outcomes.

  14. Monitoring emerging diseases of fish and shellfish using electronic sources.

    Science.gov (United States)

    Thrush, M A; Dunn, P L; Peeler, E J

    2012-10-01

    New and emerging fish and shellfish diseases represent an important constraint to the growth and sustainability of many aquaculture sectors and have also caused substantial economic and environmental impacts in wild stocks. This paper details the results of 8 years of a monitoring programme for emerging aquatic animal diseases reported around the world. The objectives were to track global occurrences and, more specifically, to identify and provide advanced warning of disease threats that may affect wild and farmed fish stocks in the UK. A range of electronic information sources, including Internet newsletters, alerting services and news agency releases, was systematically searched for reports of new diseases, new presentations of known pathogens and known diseases occurring in new geographic locations or new host species. A database was established to log the details of key findings, and 250 emerging disease events in 52 countries were recorded during the period of study. These included 14 new diseases and a further 16 known diseases in new species. Viruses and parasites accounted for the majority of reports (55% and 24%, respectively), and known diseases occurring in new locations were the most important emerging disease category (in which viruses were dominant). Emerging diseases were reported disproportionally in salmonid species (33%), in farmed populations (62%) and in Europe and North America (80%). The lack of reports from some regions with significant aquaculture or fishery production may indicate that emerging diseases are not being recognized in these areas owing to insufficient surveillance or testing or that these events are being under-reported. The results are discussed in relation to processes underpinning disease emergence in the aquatic environment. © 2011 Crown Copyright. Reproduced with the permission of the Controller of Her Majesty’s Stationery Office and Centre for Environment Fisheries & Aquaculture Science.

  15. Monitoring of environment

    Energy Technology Data Exchange (ETDEWEB)

    Mitsudera, M

    1974-09-01

    The amount of pollutants discharged has now exceeded the environment's natural ability to purify itself. The effect of urbanization is traced especially the degeneration of plants and animals in Tokyo. One of the methods of monitoring plants is remote sensing with multi-band photography and multi-spectroscanning. There is a correlation between the sulfur content of tree leaves and multi-band photograms on red pine trees with a correlation coefficient of -0.862.

  16. Deconvoluting Mixtures ofEmissions Sources to Investigate PM2.5's Ability to Generate Reactive Oxygen Species and its Associations with Cardiorespiratory Effects

    Science.gov (United States)

    Weber, R. J.; Bates, J.; Abrams, J.; Verma, V.; Fang, T.; Klein, M.; Strickland, M. J.; Sarnat, S. E.; Chang, H. H.; Mulholland, J. A.; Tolbert, P. E.; Russell, A. G.

    2015-12-01

    It is hypothesized that fine particulate matter (PM2.5) inhalation can catalytically generate reactive oxygen species (ROS) in excess of the body's antioxidant capacity, leading to oxidative stress and ultimately adverse health. PM2.5 emissions from different sources vary widely in chemical composition, with varied effects on the body. Here, the ability of mixtures of different sources of PM2.5 to generate ROS and associations of this capability with acute health effects were investigated. A dithiothreitol (DTT) assay that integrates over different sources was used to quantify ROS generation potential of ambient water-soluble PM2.5 in Atlanta from June 2012 - June 2013. PM2.5 source impacts, estimated using the Chemical Mass Balance method with ensemble-averaged source impact profiles, were related to DTT activity using a linear regression model, which provided information on intrinsic DTT activity (i.e., toxicity) of each source. The model was then used to develop a time series of daily DTT activity over a ten-year period (1998-2010) for use in an epidemiologic study. Light-duty gasoline vehicles exhibited the highest intrinsic DTT activity, followed by biomass burning and heavy-duty diesel vehicles. Biomass burning contributed the largest fraction to total DTT activity, followed by gasoline and diesel vehicles (45%, 20% and 14%, respectively). These results suggest the importance of aged oxygenated organic aerosols and metals in ROS generation. Epidemiologic analyses found significant associations between estimated DTT activity and emergency department visits for congestive heart failure and asthma/wheezing attacks in the 5-county Atlanta area. Estimated DTT activity was the only pollutant measure out of PM2.5, O3, and PM2.5 constituents elemental carbon and organic carbon) that exhibited a significant link to congestive heart failure. In two-pollutant models, DTT activity was significantly associated with asthma/wheeze and congestive heart failure while PM2

  17. Technology Transfer Opportunities: Automated Ground-Water Monitoring

    Science.gov (United States)

    Smith, Kirk P.; Granato, Gregory E.

    1997-01-01

    Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.

  18. Monitoring Information By Industry - Printing and Publishing

    Science.gov (United States)

    Stationary source emissions monitoring is required to demonstrate that a source is meeting the requirements in Federal or state rules. This page is about control techniques used to reduce pollutant emissions in the printing and publishing industry.

  19. On the general principles of health monitoring of population living in NPP environment

    International Nuclear Information System (INIS)

    Dimitrov, P.

    1991-01-01

    The basic principles of health monitoring and its significance as a source of information for the organization and regulation of health control are pointed out. Attention is drawn to the surveillance and quantitative evaluation of the factors affecting individuals, as well as their consequencies. The necessity of determining the real health status of the population, as well as of forecasting its future changes and of evaluating the prognosticated changes is stressed. The nosologic units and classes of diseases, relevant to radiation action, should be put into constant observation. Special attention is paid to the study of demographic indices, congenital malformations, neoplasms of thyroid, lungs, leucoses, osteosarcomas, reproduction ability based on data for sterile marriages, spontaneous abortions, death-borns and perinatal lethality. 9 refs., 1 tab

  20. Enhancing source location protection in wireless sensor networks

    Science.gov (United States)

    Chen, Juan; Lin, Zhengkui; Wu, Di; Wang, Bailing

    2015-12-01

    Wireless sensor networks are widely deployed in the internet of things to monitor valuable objects. Once the object is monitored, the sensor nearest to the object which is known as the source informs the base station about the object's information periodically. It is obvious that attackers can capture the object successfully by localizing the source. Thus, many protocols have been proposed to secure the source location. However, in this paper, we examine that typical source location protection protocols generate not only near but also highly localized phantom locations. As a result, attackers can trace the source easily from these phantom locations. To address these limitations, we propose a protocol to enhance the source location protection (SLE). With phantom locations far away from the source and widely distributed, SLE improves source location anonymity significantly. Theory analysis and simulation results show that our SLE provides strong source location privacy preservation and the average safety period increases by nearly one order of magnitude compared with existing work with low communication cost.

  1. Kinota: An Open-Source NoSQL implementation of OGC SensorThings for large-scale high-resolution real-time environmental monitoring

    Science.gov (United States)

    Miles, B.; Chepudira, K.; LaBar, W.

    2017-12-01

    The Open Geospatial Consortium (OGC) SensorThings API (STA) specification, ratified in 2016, is a next-generation open standard for enabling real-time communication of sensor data. Building on over a decade of OGC Sensor Web Enablement (SWE) Standards, STA offers a rich data model that can represent a range of sensor and phenomena types (e.g. fixed sensors sensing fixed phenomena, fixed sensors sensing moving phenomena, mobile sensors sensing fixed phenomena, and mobile sensors sensing moving phenomena) and is data agnostic. Additionally, and in contrast to previous SWE standards, STA is developer-friendly, as is evident from its convenient JSON serialization, and expressive OData-based query language (with support for geospatial queries); with its Message Queue Telemetry Transport (MQTT), STA is also well-suited to efficient real-time data publishing and discovery. All these attributes make STA potentially useful for use in environmental monitoring sensor networks. Here we present Kinota(TM), an Open-Source NoSQL implementation of OGC SensorThings for large-scale high-resolution real-time environmental monitoring. Kinota, which roughly stands for Knowledge from Internet of Things Analyses, relies on Cassandra its underlying data store, which is a horizontally scalable, fault-tolerant open-source database that is often used to store time-series data for Big Data applications (though integration with other NoSQL or rational databases is possible). With this foundation, Kinota can scale to store data from an arbitrary number of sensors collecting data every 500 milliseconds. Additionally, Kinota architecture is very modular allowing for customization by adopters who can choose to replace parts of the existing implementation when desirable. The architecture is also highly portable providing the flexibility to choose between cloud providers like azure, amazon, google etc. The scalable, flexible and cloud friendly architecture of Kinota makes it ideal for use in next

  2. Monitoring what is real: The effects of modality and action on accuracy and type of reality monitoring error.

    Science.gov (United States)

    Garrison, Jane R; Bond, Rebecca; Gibbard, Emma; Johnson, Marcia K; Simons, Jon S

    2017-02-01

    Reality monitoring refers to processes involved in distinguishing internally generated information from information presented in the external world, an activity thought to be based, in part, on assessment of activated features such as the amount and type of cognitive operations and perceptual content. Impairment in reality monitoring has been implicated in symptoms of mental illness and associated more widely with the occurrence of anomalous perceptions as well as false memories and beliefs. In the present experiment, the cognitive mechanisms of reality monitoring were probed in healthy individuals using a task that investigated the effects of stimulus modality (auditory vs visual) and the type of action undertaken during encoding (thought vs speech) on subsequent source memory. There was reduced source accuracy for auditory stimuli compared with visual, and when encoding was accompanied by thought as opposed to speech, and a greater rate of externalization than internalization errors that was stable across factors. Interpreted within the source monitoring framework (Johnson, Hashtroudi, & Lindsay, 1993), the results are consistent with the greater prevalence of clinically observed auditory than visual reality discrimination failures. The significance of these findings is discussed in light of theories of hallucinations, delusions and confabulation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  3. Connectivity patterns in cognitive control networks predict naturalistic multitasking ability.

    Science.gov (United States)

    Wen, Tanya; Liu, De-Cyuan; Hsieh, Shulan

    2018-06-01

    Multitasking is a fundamental aspect of everyday life activities. To achieve a complex, multi-component goal, the tasks must be subdivided into sub-tasks and component steps, a critical function of prefrontal networks. The prefrontal cortex is considered to be organized in a cascade of executive processes from the sensorimotor to anterior prefrontal cortex, which includes execution of specific goal-directed action, to encoding and maintaining task rules, and finally monitoring distal goals. In the current study, we used a virtual multitasking paradigm to tap into real-world performance and relate it to each individual's resting-state functional connectivity in fMRI. While did not find any correlation between global connectivity of any of the major networks with multitasking ability, global connectivity of the lateral prefrontal cortex (LPFC) was predictive of multitasking ability. Further analysis showed that multivariate connectivity patterns within the sensorimotor network (SMN), and between-network connectivity of the frontoparietal network (FPN) and dorsal attention network (DAN), predicted individual multitasking ability and could be generalized to novel individuals. Together, these results support previous research that prefrontal networks underlie multitasking abilities and show that connectivity patterns in the cascade of prefrontal networks may explain individual differences in performance. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. The SLAC polarized electron source

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Alley, R.; Frisch, J.; Kotseroglou, T.; Mulhollan, G.; Schultz, D.; Tang, H.; Turner, J.; Yeremian, A.D.

    1997-08-01

    Since 1992, the SLAC 3-km linac has operated exclusively with polarized electrons. The polarized electron source is highly reliable, remotely operated and monitored, and able to produce a variety of electron bunch profiles for high-energy physics experiments. The source and its operating characteristics are described. Some implications drawn from the operating experience are discussed

  5. Radioactive Plumes Monitoring Simulator

    International Nuclear Information System (INIS)

    Kapelushnik, I.; Sheinfeld, M.; Avida, R.; Kadmon, Y.; Ellenbogen, M.; Tirosh, D.

    1999-01-01

    The Airborne Radiation Monitoring System (ARMS) monitors air or ground radioactive contamination. The contamination source can be a radioactive plume or an area contaminated with radionuclides. The system is based on two major parts, an airborne unit carried by a helicopter and a ground station carried by a truck. The system enables real time measurement and analysis of radioactive plumes as well as post flight processing. The Radioactive Plumes Monitoring Simulator purpose is to create a virtual space where the trained operators experience full radiation field conditions, without real radiation hazard. The ARMS is based on a flying platform and hence the simulator allows a significant reduction of flight time costs

  6. Best Management Practices Monitoring Guide for Stream Systems

    OpenAIRE

    Mesner, Nancy

    2011-01-01

    Best Management Practices Monitoring Guide for Stream Systems provides guidance on establishing a water quality monitoring program that will demonstrate the effectiveness of Best Management Practices (BMPs) to reduce nonpoint source pollution in stream systems.

  7. How to Decide? Multi-Objective Early-Warning Monitoring Networks for Water Suppliers

    Science.gov (United States)

    Bode, Felix; Loschko, Matthias; Nowak, Wolfgang

    2015-04-01

    Groundwater is a resource for drinking water and hence needs to be protected from contaminations. However, many well catchments include an inventory of known and unknown risk sources, which cannot be eliminated, especially in urban regions. As a matter of risk control, all these risk sources should be monitored. A one-to-one monitoring situation for each risk source would lead to a cost explosion and is even impossible for unknown risk sources. However, smart optimization concepts could help to find promising low-cost monitoring network designs. In this work we develop a concept to plan monitoring networks using multi-objective optimization. Our considered objectives are to maximize the probability of detecting all contaminations, to enhance the early warning time before detected contaminations reach the drinking water well, and to minimize the installation and operating costs of the monitoring network. Using multi-objectives optimization, we avoid the problem of having to weight these objectives to a single objective-function. These objectives are clearly competing, and it is impossible to know their mutual trade-offs beforehand - each catchment differs in many points and it is hardly possible to transfer knowledge between geological formations and risk inventories. To make our optimization results more specific to the type of risk inventory in different catchments we do risk prioritization of all known risk sources. Due to the lack of the required data, quantitative risk ranking is impossible. Instead, we use a qualitative risk ranking to prioritize the known risk sources for monitoring. Additionally, we allow for the existence of unknown risk sources that are totally uncertain in location and in their inherent risk. Therefore, they can neither be located nor ranked. Instead, we represent them by a virtual line of risk sources surrounding the production well. We classify risk sources into four different categories: severe, medium and tolerable for known risk

  8. Remote data monitoring for CDF

    International Nuclear Information System (INIS)

    Kippenhan, H.A. Jr.; Lidinsky, W.; Roediger, G.

    1995-11-01

    Remote data monitoring from the physicists' home institutions has become an important issue in large international experiments to ensure high performance of the detectors and high quality of data and scientific results. The CDF experiment is a collaboration of 450 physicists from 36 institutions in the U.S., Japan, Canada, Italy and Taiwan. Future experiments at Fermilab, CERN and elsewhere will be even larger, and will be performed over a period of order 10 years. The ability of collaborators at remote sites to monitor the increasingly complex detectors and feed the results back into the data acquisition process will be of great importance We report on the status and performance of remote monitoring from Japan of the CDF experiment in Batavia Illinois. We also discuss feasibilities for modest Remote Control Rooms

  9. Submicron aerosol source apportionment of wintertime pollution in Paris, France by double positive matrix factorization (PMF2) using an aerosol chemical speciation monitor (ACSM) and a multi-wavelength Aethalometer

    International Nuclear Information System (INIS)

    Petit, J.E.; Favez, O.; Leoz-Garziandia, E.; Sciare, J.

    2014-01-01

    Online non-refractory submicron aerosol mass spectrometer (AMS) measurements in urban areas have successfully allowed the apportionment of specific sources and/or physical and chemical properties of the organic fraction. However, in order to be fully representative of PM pollution, a comprehensive source apportionment analysis is needed by taking into account all major components of submicron aerosols, creating strengthened bonds between the organic components and pollution sources. We present here a novel two-step methodology to perform such an analysis, by taking advantage of high time resolution of monitoring instruments: the aerosol chemical speciation monitor (ACSM) and the multi-wavelength absorption measurements (Aethalometer AE31) in Paris, France. As a first step, organic aerosols (OA) were de-convolved to hydrocarbon-like OA (HOA), biomass burning OA (BBOA) and oxygenated OA (OOA) with positive matrix factorization (PMF), and black carbon was de-convolved into its wood burning and fossil fuel combustion fractions. A second PMF analysis was then carried out with organic factors, BC fractions and inorganic species (nitrate, sulfate, ammonium, chloride), leading to a four-factor solution allowing highly time-resolved characterization of the major sources of PM1. Outputs of this PMF2 include two dominant combustion sources (wood burning and traffic) as well as semi-volatile and low-volatile secondary aerosols. While HOA is found to be emitted by both wood burning and traffic, the latter sources occurred to significantly contribute also to OOA. (authors)

  10. Effluent release limits, sources and control

    International Nuclear Information System (INIS)

    Swindell, G.E.

    1977-01-01

    Objectives of radiation protection in relation to releases. Environmental transfer models for radionuclides. Relationship between releases, environmental levels and doses to persons. Establishment of release limits: Limits based on critical population group concept critical pathway analysis and identification of critical group. Limits based on optimization of radiation protection individual dose limits, collective doses and dose commitments 1) differential cost benefit analysis 2) authorized and operational limits taking account of future exposures. Monitoring of releases to the environment: Objectives of effluent monitoring. Typical sources and composition of effluents; design and operation of monitoring programmes; recording and reporting of monitoring results; complementary environmental monitoring. (orig.) [de

  11. Work ability as prognostic risk marker of disability pension : Single-item work ability score versus multi-item work ability index

    NARCIS (Netherlands)

    Roelen, C.A.M.; Rhenen, van W.; Groothoff, J.W.; Klink, van der J.J.L.; Twisk, W.R.; Heymans, M.W.

    2014-01-01

    Work ability predicts future disability pension (DP). A single-item work ability score (WAS) is emerging as a measure for work ability. This study compared single-item WAS with the multi-item work ability index (WAI) in its ability to identify workers at risk of DP.

  12. Can a Concussion History Affect the Susceptibility to the Misinformation Effect?

    Directory of Open Access Journals (Sweden)

    Geoffrey Genova

    2018-04-01

    Full Text Available Concussions have been shown to have damaging effects to multiple functions of the brain, including memory. One of the key components of memory is the ability to determine the original source of a memory, a concept called source monitoring. The current study was designed to explore how individuals with a history of concussions would compare with individuals without a concussion history when their source monitoring ability was tested. The researchers investigated the influence a concussion history would have on the susceptibility to the effects of misinformation. Twenty individuals with a concussion history and twenty-two individuals without a concussion history participated in the study. It was expected that individuals without a concussion history would perform better on tests evaluating their ability to correctly monitor the source of information. Statistical analysis revealed that both the concussed and non-concussed group performed similarly in their ability to source monitor. The contradictory results this study exhibits, when compared to previous research, suggests that further exploration into this particular portion of memory may be useful when understanding how concussions affect memory performance. The results of this study suggest that concussions may not always produce negative long- term memory related cognitive effects.

  13. Sender’s Self-Monitoring Traits: Conducive Factors Affecting Interpersonal Communication among Turkish University Students

    OpenAIRE

    Sütcü, Cem Sefa; Algül, And; Uralman, N Hanzade

    2015-01-01

    Self-monitoring researches show that high self-monitoring individuals have not only ability to self-disclosure but also have ability to facilitate others’ disclosure. The aim of this paper is to define this conducive factors understanding which communication skills of university students in Turkey facilitate others’ disclosure and create dialogic communication. In this study, 24 questions have been directed at participants, in order to make a determination in relation to the conducive skills ...

  14. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  15. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  16. Work ability as prognostic risk marker of disability pension: single-item work ability score versus multi-item work ability index

    NARCIS (Netherlands)

    Roelen, C.A.M.; van Rhenen, W.; Groothoff, J.W.; van der Klink, J.J.L.; Twisk, J.W.R.; Heymans, M.W.

    2014-01-01

    Objectives Work ability predicts future disability pension (DP). A single-item work ability score (WAS) is emerging as a measure for work ability. This study compared single-item WAS with the multi-item work ability index (WAI) in its ability to identify workers at risk of DP. Methods This

  17. Work ability as prognostic risk marker of disability pension : single-item work ability score versus multi-item work ability index

    NARCIS (Netherlands)

    Roelen, Corne A. M.; van Rhenen, Willem; Groothoff, Johan W.; van der Klink, Jac J. L.; Twisk, Jos W. R.; Heymans, Martijn W.

    Objectives Work ability predicts future disability pension (DP). A single-item work ability score (WAS) is emerging as a measure for work ability. This study compared single-item WAS with the multi-item work ability index (WAI) in its ability to identify workers at risk of DP. Methods This

  18. Experimental study of ERT monitoring ability to measure solute dispersion.

    Science.gov (United States)

    Lekmine, Grégory; Pessel, Marc; Auradou, Harold

    2012-01-01

    This paper reports experimental measurements performed to test the ability of electrical resistivity tomography (ERT) imaging to provide quantitative information about transport parameters in porous media such as the dispersivity α, the mixing front velocity u, and the retardation factor R(f) associated with the sorption or trapping of the tracers in the pore structure. The flow experiments are performed in a homogeneous porous column placed between two vertical set of electrodes. Ionic and dyed tracers are injected from the bottom of the porous media over its full width. Under such condition, the mixing front is homogeneous in the transverse direction and shows an S-shape variation in the flow direction. The transport parameters are inferred from the variation of the concentration curves and are compared with data obtained from video analysis of the dyed tracer front. The variations of the transport parameters obtained from an inversion performed by the Gauss-Newton method applied on smoothness-constrained least-squares are studied in detail. While u and R(f) show a relatively small dependence on the inversion procedure, α is strongly dependent on the choice of the inversion parameters. Comparison with the video observations allows for the optimization of the parameters; these parameters are found to be robust with respect to changes in the flow condition and conductivity contrast. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  19. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  20. MonitoringResources.org—Supporting coordinated and cost-effective natural resource monitoring across organizations

    Science.gov (United States)

    Bayer, Jennifer M.; Scully, Rebecca A.; Weltzin, Jake F.

    2018-05-21

    Natural resource managers who oversee the Nation’s resources require data to support informed decision-making at a variety of spatial and temporal scales that often cross typical jurisdictional boundaries such as states, agency regions, and watersheds. These data come from multiple agencies, programs, and sources, often with their own methods and standards for data collection and organization. Coordinating standards and methods is often prohibitively time-intensive and expensive. MonitoringResources.org offers a suite of tools and resources that support coordination of monitoring efforts, cost-effective planning, and sharing of knowledge among organizations. The website was developed by the Pacific Northwest Aquatic Monitoring Partnership—a collaboration of Federal, state, tribal, local, and private monitoring programs—and the U.S. Geological Survey (USGS), with funding from the Bonneville Power Administration and USGS. It is a key component of a coordinated monitoring and information network.

  1. Executive abilities in children with congenital visual impairment in mid-childhood.

    Science.gov (United States)

    Bathelt, Joe; de Haan, Michelle; Salt, Alison; Dale, Naomi Jane

    2018-02-01

    The role of vision and vision deprivation in the development of executive function (EF) abilities in childhood is little understood; aspects of EF such as initiative, attention orienting, inhibition, planning and performance monitoring are often measured through visual tasks. Studying the development and integrity of EF abilities in children with congenital visual impairment (VI) may provide important insights into the development of EF and also its possible relationship with vision and non-visual senses. The current study investigates non-visual EF abilities in 18 school-age children of average verbal intelligence with VI of differing levels of severity arising from congenital disorders affecting the eye, retina, or anterior optic nerve. Standard auditory neuropsychological assessments of sustained and divided attention, phonemic, semantic and switching verbal fluency, verbal working memory, and ratings of everyday executive abilities by parents were undertaken. Executive skills were compared to age-matched typically-sighted (TS) typically-developing children and across levels of vision (mild to moderate VI [MVI] or severe to profound VI [SPVI]). The results do not indicate significant differences or deficits on direct assessments of verbal and auditory EF between the groups. However, parent ratings suggest difficulties with everyday executive abilities, with the greatest difficulties in those with SPVI. The findings are discussed as possibly reflecting increased demands of behavioral executive skills for children with VI in everyday situations despite auditory and verbal EF abilities in the typical range for their age. These findings have potential implications for clinical and educational practices.

  2. Monitoring well design and sampling techniques at NAPL sites

    International Nuclear Information System (INIS)

    Collins, M.; Rohrman, W.R.; Drake, K.D.

    1992-01-01

    The existence of Non-Aqueous Phase Liquids (NAPLs) at many Superfund and RCRA hazardous waste sites has become a recognized problem in recent years. The large number of sites exhibiting this problem results from the fact that many of the most frequently used industrial solvents and petroleum products can exist as NAPLs. Hazardous waste constituents occurring as NAPLs possess a common characteristic that causes great concern during groundwater contamination evaluation: while solubility in water is generally very low, it is sufficient to cause groundwater to exceed Maximum Contamination Levels (MCLs). Thus, even a small quantity of NAPL within a groundwater regime can act as a point source with the ability to contaminate vast quantities of groundwater over time. This property makes it imperative that groundwater investigations focus heavily on characterizing the nature, extent, and migration pathways of NAPLs at sites where it exists. Two types of NAPLs may exist in a groundwater system. Water-immiscible liquid constituents having a specific gravity greater than one are termed Dense Non-Aqueous Phase Liquids, while those with a specific gravity less than one are considered Light Non-Aqueous Phase Liquids. For a groundwater investigation to properly characterize the two types of NAPLs, careful consideration must be given to the placement and sampling of groundwater monitoring wells. Unfortunately, technical reviewers at EPA Region VII and the Corps of Engineers find that many groundwater investigations fall short in characterizing NAPLs because several basic considerations were overlooked. Included among these are monitoring well location and screen placement with respect to the water table and significant confining units, and the ability of the well sampling method to obtain samples of NAPL. Depending on the specific gravity of the NAPL that occurs at a site, various considerations can substantially enhance adequate characterization of NAPL contaminants

  3. Crowd Sourcing.

    Science.gov (United States)

    Baum, Neil

    2016-01-01

    The Internet has contributed new words and slang to our daily vernacular. A few terms, such as tweeting, texting, sexting, blogging, and googling, have become common in most vocabularies and in many languages, and are now included in the dictionary. A new buzzword making the rounds in industry is crowd sourcing, which involves outsourcing an activity, task, or problem by sending it to people or groups outside a business or a practice. Crowd sourcing allows doctors and practices to tap the wisdom of many instead of relying only on the few members of their close-knit group. This article defines "crowd sourcing," offers examples, and explains how to get started with this approach that can increase your ability to finish a task or solve problems that you don't have the time or expertise to accomplish.

  4. Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael L.; Rots, A. H.; Primini, F. A.; Evans, I. N.; Glotfelty, K. J.; Hain, R.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory will used to generate the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  5. Modeling of the active vibroseismic monitoring

    International Nuclear Information System (INIS)

    Kovalevskij, V.V.

    2006-01-01

    The results of the mathematical modeling of vibroseismic monitoring of changes in the elastic characteristics in the interior Earth's crust zone are presented. The model of the 'Earth's crust-mantle' system with point vibrational source on the free surface is considered. The estimates of sensitivity of active monitoring method with harmonic vibrational signals is determined. (author)

  6. Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT

    International Nuclear Information System (INIS)

    Yan Guanghua; Liu, Chihray; Lu Bo; Palta, Jatinder R; Li, Jonathan G

    2008-01-01

    The purpose of this study was to choose an appropriate head scatter source model for the fast and accurate independent planar dose calculation for intensity-modulated radiation therapy (IMRT) with MLC. The performance of three different head scatter source models regarding their ability to model head scatter and facilitate planar dose calculation was evaluated. A three-source model, a two-source model and a single-source model were compared in this study. In the planar dose calculation algorithm, in-air fluence distribution was derived from each of the head scatter source models while considering the combination of Jaw and MLC opening. Fluence perturbations due to tongue-and-groove effect, rounded leaf end and leaf transmission were taken into account explicitly. The dose distribution was calculated by convolving the in-air fluence distribution with an experimentally determined pencil-beam kernel. The results were compared with measurements using a diode array and passing rates with 2%/2 mm and 3%/3 mm criteria were reported. It was found that the two-source model achieved the best agreement on head scatter factor calculation. The three-source model and single-source model underestimated head scatter factors for certain symmetric rectangular fields and asymmetric fields, but similar good agreement could be achieved when monitor back scatter effect was incorporated explicitly. All the three source models resulted in comparable average passing rates (>97%) when the 3%/3 mm criterion was selected. The calculation with the single-source model and two-source model was slightly faster than the three-source model due to their simplicity

  7. Comparison of analytic source models for head scatter factor calculation and planar dose calculation for IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Yan Guanghua [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Liu, Chihray; Lu Bo; Palta, Jatinder R; Li, Jonathan G [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States)

    2008-04-21

    The purpose of this study was to choose an appropriate head scatter source model for the fast and accurate independent planar dose calculation for intensity-modulated radiation therapy (IMRT) with MLC. The performance of three different head scatter source models regarding their ability to model head scatter and facilitate planar dose calculation was evaluated. A three-source model, a two-source model and a single-source model were compared in this study. In the planar dose calculation algorithm, in-air fluence distribution was derived from each of the head scatter source models while considering the combination of Jaw and MLC opening. Fluence perturbations due to tongue-and-groove effect, rounded leaf end and leaf transmission were taken into account explicitly. The dose distribution was calculated by convolving the in-air fluence distribution with an experimentally determined pencil-beam kernel. The results were compared with measurements using a diode array and passing rates with 2%/2 mm and 3%/3 mm criteria were reported. It was found that the two-source model achieved the best agreement on head scatter factor calculation. The three-source model and single-source model underestimated head scatter factors for certain symmetric rectangular fields and asymmetric fields, but similar good agreement could be achieved when monitor back scatter effect was incorporated explicitly. All the three source models resulted in comparable average passing rates (>97%) when the 3%/3 mm criterion was selected. The calculation with the single-source model and two-source model was slightly faster than the three-source model due to their simplicity.

  8. KEYBOARD MONITORING BASED UPON THE IMMUNOLOGIC CLONING

    Directory of Open Access Journals (Sweden)

    Yu. A. Bryukhomitsky

    2016-12-01

    Full Text Available The Biometric Keyboard Monitoring System is represented. It’s intended for permanent textindependent control and analysis of automated information data systems users’ keyboard script. It’s suggested a keyboard monitoring method, which is combined the idea and advantages of threaded method of keyboard parameters representation and immunological approach to its realization, based upon the detectors cloning model. Suggested method potentially possesses a pinpoint accuracy, higher convergence rate of classification problems solving, ability to learn on only “own” class exemplars.

  9. Predictors of Swimming Ability among Children and Adolescents in the United States

    Directory of Open Access Journals (Sweden)

    Jennifer Pharr

    2018-02-01

    Full Text Available Swimming is an important source of physical activity and a life skill to prevent drowning. However, little research has been conducted to understand predictors of swimming ability. The purpose of this study was to understand factors that predict swimming ability among children and adolescents in the United States (US. This was a cross-sectional survey conducted between February and April of 2017 across five geographically diverse cities. Participants were accessed through the Young Christian Men’s Association (YMCA and included parents of children aged 4–11 years old and adolescents aged 12–17 years old. Independent t-test, analysis of variance (ANOVA, and univariate and multivariate analyses were conducted. Several factors were significant (p ≤ 0.05 predictors of swimming ability and explained 53% of the variance in swimming ability. Variables that were positively associated with swimming ability included: ability of parent(s to swim, child/adolescent age, a best friend who enjoys swimming, water-safety knowledge, pool open all year, and encouragement to swim from parent(s. Variables that were negatively associated with swimming ability included: fear of drowning, being African American, and being female. Interventions and programs to improve the swimming ability of children and adolescents could be developed with these predictors in mind.

  10. Advanced monitoring with complex stream processing

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    Making sense of metrics and logs for service monitoring can be a complicated task. Valuable information is normally scattered across several streams of monitoring data, requiring aggregation, correlation and time-based analysis to promptly detect problems and failures. This presentations shows a solution which is used to support the advanced monitoring of the messaging services provided by the IT Department. It uses Esper, an open-source software product for Complex Event Processing (CEP), that analyses series of events for deriving conclusions from them.

  11. Personnel monitoring in geologic fields

    International Nuclear Information System (INIS)

    Romanova, I.N.; Seredin, Yu.V.

    1981-01-01

    State of radiation safety for the personnel of geologic crews carrying out neutron logging of wells using Po-Be sources has been evaluated. Given are results of development of methods for the evaluation of individual radiation loads for personnel when working with Po-Be neutron sources useful for the application in practice by a geologic logging crew as well as a quantitative evaluation of profissional radiation loads during this kind of work. The following methods are recommended for personnel monitoring: 1) calculation of whole-body irradiation doses and hands from averaged values of radiation dose rate; 2) calculational tabulated determination of irradiation doses during recharging of shanks of well instruments. Personnel monitoring by means of instrumental methods is not necessary in the considered case [ru

  12. Local and regional sources of fine and coarse particulate matter based on traffic and background monitoring

    Science.gov (United States)

    Dimitriou, Konstantinos; Kassomenos, Pavlos

    2014-05-01

    The aim of this study was to identify local and exogenous sources affecting particulate matter (PM) levels in five major cities of Northern Europe namely: London, Paris, Hamburg, Copenhagen and Stockholm. Besides local emissions, PM profile at urban and suburban areas of the European Union (EU) is also influenced by regional PM sources due to atmospheric transport, thus geographical city distribution is of a great importance. At each city, PM10, PM2.5, NO2, SO2, CO and O3 air pollution data from two air pollution monitoring stations of the EU network were used. Different background characteristics of the selected two sampling sites at each city facilitated comparisons, providing a more exact analysis of PM sources. Four source apportionment methods: Pearson correlations among the levels of particulates and gaseous pollutants, characterisation of primal component analysis components, long-range transport analysis and extrapolation of PM size distribution ratios were applied. In general, fine (PM2.5) and coarse (PM10) particles were highly correlated, thus common sources are suggested. Combustion-originated gaseous pollutants (CO, NO2, SO2) were strongly associated to PM10 and PM2.5, primarily at areas severely affected by traffic. On the contrary, at background stations neighbouring important natural sources of particles or situated in suburban areas with rural background, natural emissions of aerosols were indicated. Series of daily PM2.5/PM10 ratios showed that minimum fraction values were detected during warm periods, due to higher volumes of airborne biogenic PM coarse, mainly at stations with important natural sources of particles in their vicinity. Hybrid single-particle Lagrangian integrated trajectory model was used, in order to extract 4-day backward air mass trajectories that arrived in the five cities which are under study during days with recorded PM10 exceedances. At all five cities, a significantly large fraction of those trajectories were classified

  13. Development of gas-sampling device for 13N monitoring system

    International Nuclear Information System (INIS)

    Zhao Lihong; Gong Xueyu

    2003-01-01

    The 13 N monitoring system is used in the monitoring of the rate of leakage of the primary coolant circuit in nuclear power stations. The author introduces a gas-sampling device of the 13 Nmonitoring system. It is with a close-loop flow control system with intelligent control of Single Chip Micyoco (SCM), and has the ability to monitor and replace the filter paper automatically, to increase the automation of the device and stable operation in long time

  14. Comparison of source moment tensor recovered by diffraction stacking migration and source time reversal imaging

    Science.gov (United States)

    Zhang, Q.; Zhang, W.

    2017-12-01

    Diffraction stacking migration is an automatic location methods and widely used in microseismic monitoring of the hydraulic fracturing. It utilizes the stacking of thousands waveform to enhance signal-to-noise ratio of weak events. For surface monitoring, the diffraction stacking method is suffered from polarity reverse among receivers due to radiation pattern of moment source. Joint determination of location and source mechanism has been proposed to overcome the polarity problem but needs significantly increased computational calculations. As an effective method to recover source moment tensor, time reversal imaging based on wave equation can locate microseismic event by using interferometry on the image to extract source position. However, the time reversal imaging is very time consuming compared to the diffraction stacking location because of wave-equation simulation.In this study, we compare the image from diffraction stacking and time reversal imaging to check if the diffraction stacking can obtain similar moment tensor as time reversal imaging. We found that image produced by taking the largest imaging value at each point along time axis does not exhibit the radiation pattern, while with the same level of calculation efficiency, the image produced for each trial origin time can generate radiation pattern similar to time reversal imaging procedure. Thus it is potential to locate the source position by the diffraction stacking method for general moment tensor sources.

  15. Identification of technical guidance related to ground water monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vogelsberger, R.R.; Smith, E.D.; Broz, M.; Wright, J.C. Jr.

    1987-05-01

    Monitoring of ground water quality is a key element of ground water protection and is mandated by several federal and state laws concerned with water quality or waste management. Numerous regulatory guidance documents and technical reports discuss various aspects of ground water monitoring, but at present there is no single source of guidance on procedures and practices for ground water monitoring. This report is intended to assist US Department of Energy (DOE) officials and facility operating personnel in identifying sources of guidance for developing and implementing ground water monitoring programs that are technically sound and that comply with applicable regulations. Federal statutes and associated regulations were reviewed to identify requirements related to ground water monitoring, and over 160 documents on topics related to ground water monitoring were evaluated for their technical merit, their utility as guidance for regulatory compliance, and their relevance to DOE's needs. For each of 15 technical topics involved in ground water monitoring, the report presents (1) a review of federal regulatory requirements and representative state requirements, (2) brief descriptions of the contents and merits of available guidance documents and technical references, and (3) recommendations of the guidance documents or other technical resources that appear to be most appropriate for use in DOE's monitoring activities. The contents of the report are applicable to monitoring activities involving both radioactive and nonradioactive substances. The main sources of regulatory requirements considered in the report are the Atomic Energy Act (including the Uranium Mill Tailings Radiation Control Act), Resource Conservation and Recovery Act, Comprehensive Environmental Response, Compensation and Liability Act, Safe Drinking Water Act, Toxic Substances Control Act, and Federal Water Pollution Control Act.

  16. Identification of technical guidance related to ground water monitoring

    International Nuclear Information System (INIS)

    Vogelsberger, R.R.; Smith, E.D.; Broz, M.; Wright, J.C. Jr.

    1987-05-01

    Monitoring of ground water quality is a key element of ground water protection and is mandated by several federal and state laws concerned with water quality or waste management. Numerous regulatory guidance documents and technical reports discuss various aspects of ground water monitoring, but at present there is no single source of guidance on procedures and practices for ground water monitoring. This report is intended to assist US Department of Energy (DOE) officials and facility operating personnel in identifying sources of guidance for developing and implementing ground water monitoring programs that are technically sound and that comply with applicable regulations. Federal statutes and associated regulations were reviewed to identify requirements related to ground water monitoring, and over 160 documents on topics related to ground water monitoring were evaluated for their technical merit, their utility as guidance for regulatory compliance, and their relevance to DOE's needs. For each of 15 technical topics involved in ground water monitoring, the report presents (1) a review of federal regulatory requirements and representative state requirements, (2) brief descriptions of the contents and merits of available guidance documents and technical references, and (3) recommendations of the guidance documents or other technical resources that appear to be most appropriate for use in DOE's monitoring activities. The contents of the report are applicable to monitoring activities involving both radioactive and nonradioactive substances. The main sources of regulatory requirements considered in the report are the Atomic Energy Act (including the Uranium Mill Tailings Radiation Control Act), Resource Conservation and Recovery Act, Comprehensive Environmental Response, Compensation and Liability Act, Safe Drinking Water Act, Toxic Substances Control Act, and Federal Water Pollution Control Act

  17. Self-Monitoring: Confidence, Academic Achievement and Gender Differences in Physics

    Science.gov (United States)

    Sharma, Manjula Devi; Bewes, James

    2011-01-01

    Metacognition is the higher-order monitoring that deals with a person's regulation of thought processes and governs learning strategies and understanding in an instructional setting. The ability to appraise and judge the quality of one's own cognitive work in the course of doing it is self-monitoring. If the work needs to be done within a short…

  18. DANIDA; Air Quality Monitoring Programme. Mission 2 Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivertsen, B.

    1996-06-01

    The report deals with the EIMP (Environmental Information and Monitoring Programme for the Arab Republic of Egypt). The programme is funded by Danida which is a cooperation project between Norway and Denmark. The programme covers the monitoring of air pollution, coastal water monitoring, and the monitoring of pollution sources and emissions. This report pays the attention to the Norwegian part of the programme executed by NILU (Norwegian Institute for Air Research) which covers the development air quality monitoring network. 14 refs., 51 figs., 18 tabs.

  19. Resolution and drift measurements on the Advanced Photon Source beam position monitors

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1994-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N = 2 n , n = 1, 2, ... , 11). Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√ N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed

  20. CMS OnlineWeb-Based Monitoring

    CERN Document Server

    Wan, Zongru; Chakaberia, Irakli; Lopez-Perez, Juan Antonio; Maeshima, Kaori; Maruyama, Sho; Soha, Aron; Sulmanas, Balys; Wan, Zongru

    2012-01-01

    For large international High Energy Physics experiments, modern web technologies make the online monitoring of detector status, data acquisition status, trigger rates, luminosity, etc., accessible for the collaborators anywhere and anytime. This helps the collaborating experts monitor the status of the experiment, identify the problems, and improve data-taking efficiency. We present the Web-Based Monitoring project of the CMS experiment at the LHC of CERN. The data sources are relational databases and various messaging systems. The project provides a vast amount of in-depth information including real time data, historical trend, and correlations, in a user friendly way.

  1. CEMs turn monitoring giant

    International Nuclear Information System (INIS)

    White, J.R.

    1993-01-01

    Crucial to complying with environmental regulations is selecting appropriate pollution control equipment to capture or destroy regulated pollutants. But just as important is selecting a continuous emissions monitoring system (CEM). CEMs play a dual role in an overall compliance strategy. On one hand, they identify the type and quantity of emissions at a source as a first step for determining which regulatory requirements and control technologies are applicable. They also provide ongoing emissions data to demonstrate compliance with air and other environmental regulations. Facilities are required to monitor their processes with CEMs, or a comparable technology, under several titles of the Clean Air Act Amendments of 1990. CEMs meet regulatory requirements if they include a SO 2 concentration monitor, nitrogen oxides (NO x ) concentration monitor, volumetric flow monitor, opacity monitor, diluent gas monitor and data acquisition and handling system. The entire system and each subsystem has to be installed and certified before it can be used for compliance. A written quality assurance/quality control (QA/QC) plan for the CEMs must accompany the permit application. The acid rain rules also impose performance standards and frequent calibration checks to ensure the integrity of CEMs data

  2. Monitoring and regulation of learning in medical education: the need for predictive cues.

    Science.gov (United States)

    de Bruin, Anique B H; Dunlosky, John; Cavalcanti, Rodrigo B

    2017-06-01

    Being able to accurately monitor learning activities is a key element in self-regulated learning in all settings, including medical schools. Yet students' ability to monitor their progress is often limited, leading to inefficient use of study time. Interventions that improve the accuracy of students' monitoring can optimise self-regulated learning, leading to higher achievement. This paper reviews findings from cognitive psychology and explores potential applications in medical education, as well as areas for future research. Effective monitoring depends on students' ability to generate information ('cues') that accurately reflects their knowledge and skills. The ability of these 'cues' to predict achievement is referred to as 'cue diagnosticity'. Interventions that improve the ability of students to elicit predictive cues typically fall into two categories: (i) self-generation of cues and (ii) generation of cues that is delayed after self-study. Providing feedback and support is useful when cues are predictive but may be too complex to be readily used. Limited evidence exists about interventions to improve the accuracy of self-monitoring among medical students or trainees. Developing interventions that foster use of predictive cues can enhance the accuracy of self-monitoring, thereby improving self-study and clinical reasoning. First, insight should be gained into the characteristics of predictive cues used by medical students and trainees. Next, predictive cue prompts should be designed and tested to improve monitoring and regulation of learning. Finally, the use of predictive cues should be explored in relation to teaching and learning clinical reasoning. Improving self-regulated learning is important to help medical students and trainees efficiently acquire knowledge and skills necessary for clinical practice. Interventions that help students generate and use predictive cues hold the promise of improved self-regulated learning and achievement. This framework is

  3. Integrated Voltage—Current Monitoring and Control of Gas Metal Arc Weld Magnetic Ball-Jointed Open Source 3-D Printer

    Directory of Open Access Journals (Sweden)

    Yuenyong Nilsiam

    2015-11-01

    Full Text Available To provide process optimization of metal fabricating self-replicating rapid prototyper (RepRap 3-D printers requires a low-cost sensor and data logger system to measure current (I and voltage (V of the gas metal arc welders (GMAW. This paper builds on previous open-source hardware development to provide a real-time measurement of welder I-V where the measuring circuit is connected to two analog inputs of the Arduino that is used to control the 3-D printer itself. Franklin firmware accessed through a web interface that is used to control the printer allows storing the measured values and downloading those stored readings to the user’s computer. To test this custom current and voltage monitoring device this study reports on its use on an upgraded all metal RepRap during the printing of aluminum alloy (ER1100, ER4043, ER4943, ER4047, and ER5356. The voltage and current data were analyzed on a per alloy basis and also layer-by-layer in order to evaluate the device’s efficacy as a monitoring device for 3-D printing and the results of the integrated design are discussed.

  4. The Open Source DataTurbine Initiative: Streaming Data Middleware for Environmental Observing Systems

    Science.gov (United States)

    Fountain T.; Tilak, S.; Shin, P.; Hubbard, P.; Freudinger, L.

    2009-01-01

    The Open Source DataTurbine Initiative is an international community of scientists and engineers sharing a common interest in real-time streaming data middleware and applications. The technology base of the OSDT Initiative is the DataTurbine open source middleware. Key applications of DataTurbine include coral reef monitoring, lake monitoring and limnology, biodiversity and animal tracking, structural health monitoring and earthquake engineering, airborne environmental monitoring, and environmental sustainability. DataTurbine software emerged as a commercial product in the 1990 s from collaborations between NASA and private industry. In October 2007, a grant from the USA National Science Foundation (NSF) Office of Cyberinfrastructure allowed us to transition DataTurbine from a proprietary software product into an open source software initiative. This paper describes the DataTurbine software and highlights key applications in environmental monitoring.

  5. The effects of monitoring environment on problem-solving performance.

    Science.gov (United States)

    Laird, Brian K; Bailey, Charles D; Hester, Kim

    2018-01-01

    While effective and efficient solving of everyday problems is important in business domains, little is known about the effects of workplace monitoring on problem-solving performance. In a laboratory experiment, we explored the monitoring environment's effects on an individual's propensity to (1) establish pattern solutions to problems, (2) recognize when pattern solutions are no longer efficient, and (3) solve complex problems. Under three work monitoring regimes-no monitoring, human monitoring, and electronic monitoring-114 participants solved puzzles for monetary rewards. Based on research related to worker autonomy and theory of social facilitation, we hypothesized that monitored (versus non-monitored) participants would (1) have more difficulty finding a pattern solution, (2) more often fail to recognize when the pattern solution is no longer efficient, and (3) solve fewer complex problems. Our results support the first two hypotheses, but in complex problem solving, an interaction was found between self-assessed ability and the monitoring environment.

  6. Suggested guidelines for gas emission monitoring at danish landfills

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Scheutz, Charlotte

    2015-01-01

    Landfill gas is produced on waste disposal sites receiving organic waste resulting in emission of methane. Regulation requires that the landfill gas is managed in order to reduce emissions, but very few suggestions exist to how the landfill gas management activities are monitored, what requirements...... to the ability of the landfill gas management to reduce the emission should be set up, and how criteria are developed for when the monitoring activities can be terminated. Monitoring procedures are suggested centred on a robust method for measuring the total methane emission from the site, and quantitative...

  7. ATLAS job monitoring in the Dashboard Framework

    CERN Document Server

    Sargsyan, L; The ATLAS collaboration; Campana, S; Karavakis, E; Kokoszkiewicz, L; Saiz, P; Schovancova, J; Tuckett, D

    2012-01-01

    Monitoring of the large-scale data processing of the ATLAS experiment includes monitoring of production and user analysis jobs. The Experiment Dashboard provides a common job monitoring solution, which is shared by ATLAS and CMS experiments. This includes an accounting portal as well as real-time monitoring. Dashboard job monitoring for ATLAS combines information from PanDA job processing database, Production system database and monitoring information from jobs submitted through GANGA to Workload Management System (WMS) or local batch systems. Usage of Dashboard-based job monitoring applications will decrease load on the PanDA database and overcome scale limitations in PanDA monitoring caused by the short job rotation cycle in the PanDA database. Aggregation of the task/job metrics from different sources provides complete view of job processing activity in ATLAS scope.

  8. ATLAS job monitoring in the Dashboard Framework

    International Nuclear Information System (INIS)

    Andreeva, J; Campana, S; Karavakis, E; Kokoszkiewicz, L; Saiz, P; Tuckett, D; Sargsyan, L; Schovancova, J

    2012-01-01

    Monitoring of the large-scale data processing of the ATLAS experiment includes monitoring of production and user analysis jobs. The Experiment Dashboard provides a common job monitoring solution, which is shared by ATLAS and CMS experiments. This includes an accounting portal as well as real-time monitoring. Dashboard job monitoring for ATLAS combines information from the PanDA job processing database, Production system database and monitoring information from jobs submitted through GANGA to Workload Management System (WMS) or local batch systems. Usage of Dashboard-based job monitoring applications will decrease load on the PanDA database and overcome scale limitations in PanDA monitoring caused by the short job rotation cycle in the PanDA database. Aggregation of the task/job metrics from different sources provides complete view of job processing activity in ATLAS scope.

  9. Belgrade waterworks groundwater source

    International Nuclear Information System (INIS)

    Sotic, A.; Dasic, M.; Vukcevic, G.; Vasiljevic, Lj.; Nikolic, S.

    2002-01-01

    Paper deals with Belgrade Waterworks groundwater source, its characteristics, conception of protection programme, contaminations on source and with parameters of groundwater quality degradation. Groundwaters present natural heritage with their strategic and slow renewable natural resources attributes, and as such they require priority in protection. It is of greatest need that existing source is to be protected and used optimally for producing quality drinkable water. The concept of source protection programme should be based on regular water quality monitoring, identification of contaminators, defining areas of their influences on the source and their permanent control. However, in the last 10 years, but drastically in the last 3, because of the overall situation in the country, it is very characteristic downfall in volume of business, organisation and the level of supply of the technical equipment

  10. Development of infrared spectroscopy techniques for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sandsten, Jonas

    2000-08-01

    Infrared spectroscopy techniques have long been utilized in identifying and quantifying species of interest to us. Many of the elementary molecules in the atmosphere interact with infrared radiation through their ability to absorb and emit energy in vibrational and rotational transitions. A large variety of methods for monitoring of molecules and aerosol particles by collecting samples or by using remote sensing methods are available. The objective of the work presented in this thesis was to develop infrared spectroscopic techniques to further enhance the amount of useful information obtained from gathering spectral data. A new method for visualization and quantification of gas flows based on gas-correlation techniques was developed. Real-time imaging of gas leaks and incomplete or erratic flare combustion of ethene was demonstrated. The method relies on the thermal background as a radiation source and the gas can be visualized in absorption or in emission depending on the temperature difference. Diode laser spectroscopy was utilized to monitor three molecular species at the same time and over the same path. Two near-infrared diode lasers beams were combined in a periodically poled lithium niobate crystal and by difference-frequency generation a third beam was created, enabling simultaneous monitoring of oxygen, water vapor and methane. Models of aerosol particle cross sections were used to simulate the diffraction pattern of light scattered by fibers, spherical particles and real particles, such as pollen, through a new aerosol particle sensing prototype. The instrument, using a coupled cavity diode laser, has been designed with a ray-tracing program and the final prototype was employed for single aerosol particle sizing and identification.

  11. Five-level Z-source diode-clamped inverter

    DEFF Research Database (Denmark)

    Gao, F.; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z......-source inverter are introduced here for operating the proposed inverter with voltage buck–boost energy conversion ability and five-level phase voltage switching. These characteristic features are in fact always ensured at the inverter terminal output by simply adopting a properly designed carrier modulation...

  12. OpenLMD, multimodal monitoring and control of LMD processing

    Science.gov (United States)

    Rodríguez-Araújo, Jorge; García-Díaz, Antón

    2017-02-01

    This paper presents OpenLMD, a novel open-source solution for on-line multimodal monitoring of Laser Metal Deposition (LMD). The solution is also applicable to a wider range of laser-based applications that require on-line control (e.g. laser welding). OpenLMD is a middleware that enables the orchestration and virtualization of a LMD robot cell, using several open-source frameworks (e.g. ROS, OpenCV, PCL). The solution also allows reconfiguration by easy integration of multiple sensors and processing equipment. As a result, OpenLMD delivers significant advantages over existing monitoring and control approaches, such as improved scalability, and multimodal monitoring and data sharing capabilities.

  13. Charged particle beam monitoring by means of synchrotron radiation

    International Nuclear Information System (INIS)

    Panasyuk, V.S.; Anevskij, S.I.

    1984-01-01

    Optical methods for monitoring the number of accelerated electrons and electron energy by means of beam synchrotron radiation (SR) as well as peculiarities of SR characteristics of beams with a small radius of the orbit are considered. Optical methods for charged particle beam monitoring are shown to ensure operative and precise monitoring the number of particles and particle energy. SR sources with large axial dimensions of an electron beam have specific spectral angular and polarization characteristics. If electron angular distribution at deflection from the median plane is noticeably wider than angular distribution of SR of a certain electron, relative SR characteristics of these soUrces are calculated with high accuracy

  14. Event-related potential evidence of accessing gender stereotypes to aid source monitoring.

    Science.gov (United States)

    Leynes, P Andrew; Crawford, Jarret T; Radebaugh, Anne M; Taranto, Elizabeth

    2013-01-23

    Source memory for the speaker's voice (male or female) was investigated when semantic knowledge (gender stereotypes) could and could not inform the episodic source judgment while event-related potentials (ERPs) were recorded. Source accuracy was greater and response times were faster when stereotypes could predict the speaker's voice at test. Recollection supported source judgments in both conditions as indicated by significant parietal "old/new" ERP effects (500-800ms). Prototypical late ERP effects (the right frontal "old/new" effect and the late posterior negativity, LPN) were evident when source judgment was based solely on episodic memory. However, these two late ERP effects were diminished and a novel, frontal-negative ERP with left-central topography was observed when stereotypes aided source judgments. This pattern of ERP activity likely reflects activation of left frontal or left temporal lobes when semantic knowledge, in the form of a gender stereotype, is accessed to inform the episodic source judgment. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. The use of metacognitive strategies to decrease false memories in source monitoring in patients with mild cognitive impairment.

    Science.gov (United States)

    Deason, Rebecca G; Nadkarni, Neil A; Tat, Michelle J; Flannery, Sean; Frustace, Bruno; Ally, Brandon A; Budson, Andrew E

    2017-06-01

    Patients with amnestic mild cognitive impairment (MCI) and Alzheimer's disease (AD) often demonstrate high rates of false memories, leading to stressful and frustrating situations for both patients and caregivers in everyday life. Sometimes these false memories are due to failures in monitoring the source of the information. In the current study, we examined interventions aimed to enhance the use of the metacognitive "recall-to-reject" memory strategy. Such interventions could improve source memory and decrease false memory in patients with MCI. Because the picture superiority effect (better memory for pictures compared to words) has been shown to be present in both patients with MCI and healthy older controls, we investigated whether pictures could help patients with MCI use a recall-to-reject strategy in a simulation of real-world source memory task. In this experiment, patients with MCI and healthy older adults were asked to simulate preparing for and then taking a trip to the market. Subjects first studied 30 pictures of items in their "cupboard," followed by a list of 30 words of items on their "shopping list." At test, participants saw 90 pictures (30 cupboard, 30 list, 30 new) organized as they would be if walking down the market aisles, and are provided with either standard or metacognitive instructions. With standard instructions, they were asked if they needed to buy the item. With the metacognitive instructions, they were asked a series of questions to help guide them through a recall-to-reject strategy to highlight the different sources of memories. Results showed that the metacognitive instructions did significantly reduce the false memory rates for patients with MCI. Further studies need to investigate how to best implement these practical strategies into the everyday lives of patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Type 2 diabetes and impaired glucose tolerance are associated with word memory source monitoring recollection deficits but not simple recognition familiarity deficits following water, low glycaemic load, and high glycaemic load breakfasts.

    Science.gov (United States)

    Lamport, Daniel J; Lawton, Clare L; Mansfield, Michael W; Moulin, Chris A J; Dye, Louise

    2014-01-30

    It has been established that type 2 diabetes, and to some extent, impaired glucose tolerance (IGT), are associated with general neuropsychological impairments in episodic memory. However, the effect of abnormalities in glucose metabolism on specific retrieval processes such as source monitoring has not been investigated. The primary aim was to investigate the impact of type 2 diabetes and IGT on simple word recognition (familiarity) and complex source monitoring (recollection). A secondary aim was to examine the effect of acute breakfast glycaemic load manipulations on episodic memory. Data are presented from two separate studies; (i) 24 adults with type 2 diabetes and 12 controls aged 45-75years, (ii) 18 females with IGT and 47 female controls aged 30-50years. Controls were matched for age, IQ, BMI, waist circumference, and depression. Recognition of previously learned words and memory for specifically which list a previously learned word had appeared in (source monitoring) was examined at two test sessions during the morning after consumption of low glycaemic load, high glycaemic load and water breakfasts according to a counterbalanced, crossover design. Type 2 diabetes (pglucose metabolism are not detrimental for global episodic memory processes. This enhances our understanding of how metabolic disorders are associated with memory impairments. © 2013.

  17. Formation and migration of Natural Gases: gas composition and isotopes as monitors between source, reservoir and seep

    Science.gov (United States)

    Schoell, M.; Etiope, G.

    2015-12-01

    Natural gases form in tight source rocks at temperatures between 120ºC up to 200ºC over a time of 40 to 50my depending on the heating rate of the gas kitchen. Inferring from pyrolysis experiments, gases after primary migration, a pressure driven process, are rich in C2+ hydrocarbons (C2 to C5). This is consistent with gas compositions of oil-associated gases such as in the Bakken Shale which occur in immediate vicinity of the source with little migration distances. However, migration of gases along porous rocks over long distances (up to 200km in the case of the Troll field offshore Norway) changes the gas composition drastically as C2+ hydrocarbons tend to be retained/sequestered during migration of gas as case histories from Virginia and the North Sea will demonstrate. Similar "molecular fractionation" is observed between reservoirs and surface seeps. In contrast to gas composition, stable isotopes in gases are, in general, not affected by the migration process suggesting that gas migration is a steady state process. Changes in isotopic composition, from source to reservoir to surface seeps, is often the result of mixing of gases of different origins. Examples from various gas provinces will support this notion. Natural gas basins provide little opportunity of tracking and identifying gas phase separation. Future research on experimental phase separation and monitoring of gas composition and gas ratio changes e.g. various C2+ compound ratios over C1 or isomer ratios such as iso/n ratios in butane and pentane may be an avenue to develop tracers for phase separation that could possibly be applied to natural systems of retrograde natural condensate fields.

  18. Personal monitoring

    International Nuclear Information System (INIS)

    1995-01-01

    Sources of ionizing radiation have innumerable applications in the workplace. The potential exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Module explains the basic terminology associated with personal monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Module can only be provided by qualified experts

  19. Spectral characteristics of light sources for S-cone stimulation.

    Science.gov (United States)

    Schlegelmilch, F; Nolte, R; Schellhorn, K; Husar, P; Henning, G; Tornow, R P

    2002-11-01

    Electrophysiological investigations of the short-wavelength sensitive pathway of the human eye require the use of a suitable light source as a S-cone stimulator. Different light sources with their spectral distribution properties were investigated and compared with the ideal S-cone stimulator. First, the theoretical background of the calculation of relative cone energy absorption from the spectral distribution function of the light source is summarized. From the results of the calculation, the photometric properties of the ideal S-cone stimulator will be derived. The calculation procedure was applied to virtual light sources (computer generated spectral distribution functions with different medium wavelengths and spectrum widths) and to real light sources (blue and green light emitting diodes, blue phosphor of CRT-monitor, multimedia projector, LCD monitor and notebook display). The calculated relative cone absorbencies are compared to the conditions of an ideal S-cone stimulator. Monochromatic light sources with wavelengths of less than 456 nm are close to the conditions of an ideal S-cone stimulator. Spectrum widths up to 21 nm do not affect the S-cone activation significantly (S-cone activation change < 0.2%). Blue light emitting diodes with peak wavelength at 448 nm and spectrum bandwidth of 25 nm are very useful for S-cone stimulation (S-cone activation approximately 95%). A suitable display for S-cone stimulation is the Trinitron computer monitor (S-cone activation approximately 87%). The multimedia projector has a S-cone activation up to 91%, but their spectral distribution properties depends on the selected intensity. LCD monitor and notebook displays have a lower S-cone activation (< or = 74%). Carefully selecting the blue light source for S-cone stimulation can reduce the unwanted L-and M-cone activation down to 4% for M-cones and 1.5% for L-cones.

  20. Monitoring and predicting cognitive state and performance via physiological correlates of neuronal signals.

    Science.gov (United States)

    Russo, Michael B; Stetz, Melba C; Thomas, Maria L

    2005-07-01

    Judgment, decision making, and situational awareness are higher-order mental abilities critically important to operational cognitive performance. Higher-order mental abilities rely on intact functioning of multiple brain regions, including the prefrontal, thalamus, and parietal areas. Real-time monitoring of individuals for cognitive performance capacity via an approach based on sampling multiple neurophysiologic signals and integrating those signals with performance prediction models potentially provides a method of supporting warfighters' and commanders' decision making and other operationally relevant mental processes and is consistent with the goals of augmented cognition. Cognitive neurophysiological assessments that directly measure brain function and subsequent cognition include positron emission tomography, functional magnetic resonance imaging, mass spectroscopy, near-infrared spectroscopy, magnetoencephalography, and electroencephalography (EEG); however, most direct measures are not practical to use in operational environments. More practical, albeit indirect measures that are generated by, but removed from the actual neural sources, are movement activity, oculometrics, heart rate, and voice stress signals. The goal of the papers in this section is to describe advances in selected direct and indirect cognitive neurophysiologic monitoring techniques as applied for the ultimate purpose of preventing operational performance failures. These papers present data acquired in a wide variety of environments, including laboratory, simulator, and clinical arenas. The papers discuss cognitive neurophysiologic measures such as digital signal processing wrist-mounted actigraphy; oculometrics including blinks, saccadic eye movements, pupillary movements, the pupil light reflex; and high-frequency EEG. These neurophysiological indices are related to cognitive performance as measured through standard test batteries and simulators with conditions including sleep loss

  1. The Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael; Rots, Arnold; Primini, Francis A.; Evans, Ian N.; Glotfelty, Kenny J.; Hain, Roger; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Danny G. Gibbs, II; Grier, John D.; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.; Zografou, Panagoula

    2009-09-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory are used to generate one of the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  2. Prototype plutonium-storage monitor

    International Nuclear Information System (INIS)

    Bliss, M.; Craig, R.A.; Sunberg, D.S.; Warner, R.A.

    1996-01-01

    Pacific Northwest National Laboratory (PNNL) has fabricated cerium-activated lithium silicate scintillating fibers via a hot-downdraw process. These fibers typically have an operational transmission length (e -1 length) of greater than 2 meters. This permits the fabrication of devices that, hitherto, were not possible to consider. A prototype neutron monitor for scrap Pu-storage containers was fabricated and tested for 70 days, taking data with a variety of sources in a high-background environment. These data and their implication in the context of a storage-monitor situation are discussed

  3. On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines

    International Nuclear Information System (INIS)

    Resano, M.; Rello, L.; Florez, M.; Belarra, M.A.

    2011-01-01

    This paper explores the potential of commercially available high-resolution continuum source graphite furnace atomic absorption spectrometry instrumentation for the simultaneous or sequential monitoring of various atomic lines, in an attempt to highlight the analytical advantages that can be derived from this strategy. In particular, it is demonstrated how i) the monitoring of multiplets may allow for the simple expansion of the linear range, as shown for the measurement of Ni using the triplet located in the vicinity of 234.6 nm; ii) the use of a suitable internal standard may permit improving the precision and help in correcting for matrix-effects, as proved for the monitoring of Ni in different biological samples; iii) direct and multi-element analysis of solid samples may be feasible on some occasions, either by monitoring various atomic lines that are sufficiently close (truly simultaneous monitoring, as demonstrated in the determination of Co, Fe and Ni in NIST 1566a Oyster tissue) or, alternatively, by opting for a selective and sequential atomization of the elements of interest during every single replicate. Determination of Cd and Ni in BCR 679 White cabbage is attempted using both approaches, which permits confirming that both methods can offer very similar and satisfactory results. However, it is important to stress that the second approach provides more flexibility, since analysis is no longer limited to those elements that show very close atomic lines (closer than 0.3 nm in the ultraviolet region) with a sensitivity ratio similar to the concentration ratio of the analytes in the samples investigated.

  4. Sources of variability in human communicative skills

    Directory of Open Access Journals (Sweden)

    Inge eVolman

    2012-11-01

    Full Text Available When established communication systems cannot be used, people rapidly create novel systems to modify the mental state of another agent according to their intentions. However, there are dramatic inter-individual differences in the implementation of this human competence for communicative innovation. Here we characterize psychological sources of inter-individual variability in the ability to build a shared communication system from scratch. We consider two potential sources of variability in communicative skills. Cognitive traits of two individuals could independently influence their joint ability to establish a communication system. Another possibility is that the overlap between those individual traits influences the communicative performance of a dyad. We assess these possibilities by quantifying the relationship between cognitive traits and behavior of communicating dyads. Cognitive traits were assessed with psychometric scores quantifying cooperative attitudes and fluid intelligence. Competence for implementing successful communicative innovations was assessed by using a non-verbal communicative task. Individual capacities influence communicative success when communicative innovations are generated. Dyadic similarities and individual traits modulate the type of communicative strategy chosen. The ability to establish novel communicative actions was influenced by a combination of the communicator’s ability to understand intentions and the addressee’s ability to recognize patterns. Communicative pairs with comparable systemizing abilities or behavioral inhibition were more likely to explore the search space of possible communicative strategies by systematically adding new communicative behaviors to those already available. No individual psychometric measure seemed predominantly responsible for communicative success. These findings support the notion that the human ability for fast communicative innovations represents a special type of

  5. Facility effluent monitoring plan for WESF

    Energy Technology Data Exchange (ETDEWEB)

    SIMMONS, F.M.

    1999-09-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the effluent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability.

  6. Facility effluent monitoring plan for WESF

    International Nuclear Information System (INIS)

    SIMMONS, F.M.

    1999-01-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the efferent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability

  7. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  8. Systematic approach to personnel neutron monitoring

    International Nuclear Information System (INIS)

    Griffith, R.V.; Hankins, D.E.

    1980-01-01

    NTA film and albedo detectors represent the major portion of personnel dosimeters now used for occupational neutron monitoring. However, recent attention to the spectral response of these systems has demonstrated the need for detectors that have a better match to the fields being monitored. Recent developments in direct recoil track etch dosimeters present some intriguing alternatives, and careful use of 237 Np fission fragment detectors offers the advantage of a good dose equivalent spectral match. Work continues on a number of other new detector mechanisms, but problems with sensitivity, energy response, gamma interference, etc., continue to prevent development of most mechanisms into viable personnel dosimeters. Current dosimeter limitations make a systematic approach to personnel neutron monitoring particularly important. Techniques have been developed and tested, using available portable survey instruments, that significantly improve the quality of dosimeter interpretation. Even simple spectrometry can be done with modest effort, significantly improving the health physicists ability to provide accurate neutron monitoring

  9. The Circumpolar Biodiversity Monitoring Program Terrestrial Plan

    DEFF Research Database (Denmark)

    Christensen, Tom; Payne, J.; Doyle, M.

    , understand and report on long-term change in Arctic terrestrial ecosystems and biodiversity, and to identify knowledge gaps and priorities. This poster will outline the key management questions the plan aims to address and the proposed nested, multi-scaled approach linking targeted, research based monitoring...... and coastal environments. The CBMP Terrestrial Plan is a framework to focus and coordinate monitoring of terrestrial biodiversity across the Arctic. The goal of the plan is to improve the collective ability of Arctic traditional knowledge (TK) holders, northern communities, and scientists to detect...

  10. Sub-nanometer emittance monitor for high brightness synchrotron radiation source

    International Nuclear Information System (INIS)

    Nakajima, K.

    1991-01-01

    Method of measuring a very small beam emittance in electron storage rings is presented. The monitor can sense an intrinsic emittance of beam particles by detecting the angular distribution of Compton scatterings of laser photons on beam electrons. It is possible to achieve measurement resolution smaller than 10 -9 m-rad without difficulty. (author)

  11. Ozone Measurements Monitoring Using Data-Based Approach

    KAUST Repository

    Harrou, Fouzi; Kadri, Farid; Khadraoui, Sofiane; Sun, Ying

    2016-01-01

    The complexity of ozone (O3) formation mechanisms in the troposphere make the fast and accurate modeling of ozone very challenging. In the absence of a process model, principal component analysis (PCA) has been extensively used as a data-based monitoring technique for highly correlated process variables; however conventional PCA-based detection indices often fail to detect small or moderate anomalies. In this work, we propose an innovative method for detecting small anomalies in highly correlated multivariate data. The developed method combine the multivariate exponentially weighted moving average (MEWMA) monitoring scheme with PCA modelling in order to enhance anomaly detection performance. Such a choice is mainly motivated by the greater ability of the MEWMA monitoring scheme to detect small changes in the process mean. The proposed PCA-based MEWMA monitoring scheme is successfully applied to ozone measurements data collected from Upper Normandy region, France, via the network of air quality monitoring stations. The detection results of the proposed method are compared to that declared by Air Normand air monitoring association.

  12. Ozone Measurements Monitoring Using Data-Based Approach

    KAUST Repository

    Harrou, Fouzi

    2016-02-01

    The complexity of ozone (O3) formation mechanisms in the troposphere make the fast and accurate modeling of ozone very challenging. In the absence of a process model, principal component analysis (PCA) has been extensively used as a data-based monitoring technique for highly correlated process variables; however conventional PCA-based detection indices often fail to detect small or moderate anomalies. In this work, we propose an innovative method for detecting small anomalies in highly correlated multivariate data. The developed method combine the multivariate exponentially weighted moving average (MEWMA) monitoring scheme with PCA modelling in order to enhance anomaly detection performance. Such a choice is mainly motivated by the greater ability of the MEWMA monitoring scheme to detect small changes in the process mean. The proposed PCA-based MEWMA monitoring scheme is successfully applied to ozone measurements data collected from Upper Normandy region, France, via the network of air quality monitoring stations. The detection results of the proposed method are compared to that declared by Air Normand air monitoring association.

  13. Developing a source-receptor methodology for the characterization of VOC sources in ambient air

    International Nuclear Information System (INIS)

    Borbon, A.; Badol, C.; Locoge, N.

    2005-01-01

    Since 2001, in France, a continuous monitoring of about thirty ozone precursor non-methane hydrocarbons (NMHC) is led in some urban areas. The automated system for NMHC monitoring consists of sub-ambient preconcentration on a cooled multi-sorbent trap followed by thermal desorption and bidimensional Gas Chromatography/Flame Ionisation Detection analysis.The great number of data collected and their exploitation should provide a qualitative and quantitative assessment of hydrocarbon sources. This should help in the definition of relevant strategies of emission regulation as stated by the European Directive relative to ozone in ambient air (2002/3/EC). The purpose of this work is to present the bases and the contributions of an original methodology known as source-receptor in the characterization of NMHC sources. It is a statistical and diagnostic approach, adaptable and transposable in all urban sites, which integrates the spatial and temporal dynamics of the emissions. The methods for source identification combine descriptive or more complex complementary approaches: 1) univariate approach through the analysis of NMHC time series and concentration roses, 2) bivariate approach through a Graphical Ratio Analysis and a characterization of scatterplot distributions of hydrocarbon pairs, 3) multivariate approach with Principal Component Analyses on various time basis. A linear regression model is finally developed to estimate the spatial and temporal source contributions. Apart from vehicle exhaust emissions, sources of interest are: combustion and fossil fuel-related activities, petrol and/or solvent evaporation, the double anthropogenic and biogenic origin of isoprene and other industrial activities depending on local parameters. (author)

  14. National physical activity surveillance: Users of wearable activity monitors as a potential data source

    Directory of Open Access Journals (Sweden)

    John D. Omura, MD

    2017-03-01

    Full Text Available The objective of this study was to assess usage patterns of wearable activity monitors among US adults and how user characteristics might influence physical activity estimates from this type of sample. We analyzed data on 3367 respondents to the 2015 HealthStyles survey, an annual consumer mail panel survey conducted on a nationwide sample. Approximately 1 in 8 respondents (12.5% reported currently using a wearable activity monitor. Current use varied by sex, age, and education level. Use increased with physical activity level from 4.3% for inactive adults to 17.4% for active adults. Overall, 49.9% of all adults met the aerobic physical activity guideline, while this prevalence was 69.5% among current activity monitor users. Our findings suggest that current users of wearable activity monitors are not representative of the overall US population. Estimates of physical activity levels using data from wearable activity monitors users may be an overestimate and therefore data from users alone may have a limited role in physical activity surveillance.

  15. The beam based alignment technique for the measurements of beam position monitors offsets and beam offsets from quadrupoles in the Pohang Light Source

    International Nuclear Information System (INIS)

    Kim, K.H.; Huang, J.Y.; Ko, I.S.

    1999-01-01

    The beam based alignment (BBA) technique is applied to the 2-GeV storage ring of the Pohang Light Source to measure the offsets of beam position monitors. This measurement is particularly necessary for beam position monitors (BPMs) plugged into a long (∼10 m) aluminum chamber, since the mechanical deformation of the vacuum chamber is experienced after repeated heating for the outgassing process, and the BPM positions are changed accordingly. A part of the excitation current of each quadrupole magnet is shunted through an electronic shunt circuit. Then, the closed orbit receives a perturbation due to the current reduction. Using two quadrupole magnets, we can measure the offset of each BPM. Also, the BBA technique is applied to measure the beam offsets from the center of quadrupole magnets, and gives information to the survey team about which quadrupole magnets should be aligned mostly. In this process, we introduce the merit function to reduce various errors such as BPM characteristic changes and the lattice imperfection. By minimizing the merit function, we can get the beam offset as the maximized expectation value. This paper presents the BBA technique used and experimental results taken from the 2-GeV Pohang Light Source (PLS) storage ring. When the BPM offset is measured, it is observed that a 3% of the shunt current is suitable. (author)

  16. Novel remote monitoring platform for RES-hydrogen based smart microgrid

    International Nuclear Information System (INIS)

    González, I.; Calderón, A.J.; Andújar, J.M.

    2017-01-01

    Highlights: • A remote monitoring platform is developed to monitor an experimental smart microgrid. • Smart microgrid integrates renewable energy sources (solar and wind) and hydrogen. • The platform is implemented using open-source tool Easy Java/Javascript Simulations. • Remote user accesses online to graphical/numerical information of all components. • Results show proper operation of the SMG and prove effective real-time monitoring. - Abstract: In the context of the future power grids – Smart Grids (SGs) – Smart MicroGrids (SMGs) play a paramount role. These ones are very specific portions of the SGs that deal with integration of small-rated distributed energy and storage resources closer to the loads – chiefly within the distribution domain. Data acquisition and monitoring tasks are vital functions that must be developed at every stage of the grid for a proper operation. This paper presents a remote monitoring platform (RMP) to monitor an experimental SMG. It integrates Renewable Energy Sources (RESs) (solar and wind) and hydrogen to operate in isolated regime. The RMP has been developed using the open-source authoring tool Easy Java/Javascript Simulations (EJsS). The interface has been designed to be intuitive and easy-to-use, providing real-time information of all the involved magnitudes over the network. Scalability, easy development, portability and cost effective are the main features of the proposed framework. The microgrid and the proposed monitoring platform are described and the successful results are reported. The remote user executes a ready-to-use file with low computational requirements and is enabled to graphically and numerically track the SMG behaviour. These results prove the suitability of the RMP as an effective means for continuous visualization of the coordinated energy flows of a real SMG.

  17. Sex Differences in Fluid Reasoning: Manifest and Latent Estimates from the Cognitive Abilities Test

    Directory of Open Access Journals (Sweden)

    Joni M. Lakin

    2014-06-01

    Full Text Available The size and nature of sex differences in cognitive ability continues to be a source of controversy. Conflicting findings result from the selection of measures, samples, and methods used to estimate sex differences. Existing sex differences work on the Cognitive Abilities Test (CogAT has analyzed manifest variables, leaving open questions about sex differences in latent narrow cognitive abilities and the underlying broad ability of fluid reasoning (Gf. This study attempted to address these questions. A confirmatory bifactor model was used to estimate Gf and three residual narrow ability factors (verbal, quantitative, and figural. We found that latent mean differences were larger than manifest estimates for all three narrow abilities. However, mean differences in Gf were trivial, consistent with previous research. In estimating group variances, the Gf factor showed substantially greater male variability (around 20% greater. The narrow abilities varied: verbal reasoning showed small variability differences while quantitative and figural showed substantial differences in variance (up to 60% greater. These results add precision and nuance to the study of the variability and masking hypothesis.

  18. Interactive monitoring portal for fusion simulations

    International Nuclear Information System (INIS)

    Abla, G.; Schissel, D.P.; Kim, E.N.; Flanagan, S.M.; Lee, X.

    2012-01-01

    Highlights: ► We designed a web-based monitoring system that tracks the status of fusion simulations. ► Our system is scalable to monitor the simulations running on distributed supercomputers and clusters located at multiple geographical locations. ► The monitoring portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. ► Our system utilizes the open source software, such as Python, Django, MySQL, Apache, and MDSplus. - Abstract: The Center for Simulation of RF Wave Interactions with Magnetohydrodynamics (SWIM) Project is a proto-Fusion Simulation Program (FSP) whose goal is to study high-performance fusion plasmas and perform comprehensive simulations that are essential to the development of fusion. SWIM team members are geographically distributed and utilize distributed supercomputers for computational simulations. Due to the highly distributed computational work environment, the SWIM team has the difficulty of monitoring code runs and discovering historical runs. To alleviate this difficulty a web-based monitoring portal has been developed and deployed. The monitoring portal tracks the progress of simulations and automatically collects metadata in real-time. This capability helps scientists to effectively utilize precious computer resources. Furthermore, the portal provides a web-based interface for post-run analysis, such as visualizing the results, logging the user comments, and rating the simulation quality. The user interface provides rapid discovery capability via multi-field searching and sorting. The development of the monitoring portal used open source software, such as Python, Django, MySQL, and Apache. It uses MDSplus for data management, Memcached for data caches, and OpenID for single sign-on security. This paper describes the software architecture, related technologies and deployment experiences of the monitoring portal.

  19. Measurement of Detector Efficiency for the CZT Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kang Hwa; Kon, Kang Seo; Kim, Jeongin [KHNP, Radiation Health Research Institute, Seoul (Korea, Republic of)

    2014-05-15

    Evaluation method of using CZT have been being attempted in various places such as AEP(American Electronic Power) etc since EDF(Electricite de France) had apply to the project named 'Source Term Reduction'. CZT can measure source terms on various places in nuclear power plants because it is available at room temperature unless a seperate device and portability is good. Consequently, CZT show good result from analysis of source terms in nuclear power plants. This study found out efficiency of CZT detector that is now researched in CZT Monitoring System for measure source terms on RCS system of domestic old and new nuclear power plants and verified measured efficiency values by comparing to reference efficiency we already know. This study was carried out for finding out detector's efficiency depending on necessary energy in order to save quantitative radioactivity value of source terms. Eventually, this study is to develope CZT Monitoring System measuring CRUD in domestic PWRs primary system or piping system by carrying out in-vivo. Considering error ratio ±20% on radioactivity value of CRM used in measuring and verifying efficiency, measurement of detector Efficiency for the CZT Monitoring System is good. But more various tests is needed than now for an accurate measurement.

  20. Photon beam position monitor

    Science.gov (United States)

    Kuzay, Tuncer M.; Shu, Deming

    1995-01-01

    A photon beam position monitor for use in the front end of a beamline of a high heat flux and high energy photon source such as a synchrotron radiation storage ring detects and measures the position and, when a pair of such monitors are used in tandem, the slope of a photon beam emanating from an insertion device such as a wiggler or an undulator inserted in the straight sections of the ring. The photon beam position monitor includes a plurality of spaced blades for precisely locating the photon beam, with each blade comprised of chemical vapor deposition (CVD) diamond with an outer metal coating of a photon sensitive metal such as tungsten, molybdenum, etc., which combination emits electrons when a high energy photon beam is incident upon the blade. Two such monitors are contemplated for use in the front end of the beamline, with the two monitors having vertically and horizontally offset detector blades to avoid blade "shadowing". Provision is made for aligning the detector blades with the photon beam and limiting detector blade temperature during operation.

  1. [Monitoring social determinants of health].

    Science.gov (United States)

    Espelt, Albert; Continente, Xavier; Domingo-Salvany, Antonia; Domínguez-Berjón, M Felicitas; Fernández-Villa, Tania; Monge, Susana; Ruiz-Cantero, M Teresa; Perez, Glòria; Borrell, Carme

    2016-11-01

    Public health surveillance is the systematic and continuous collection, analysis, dissemination and interpretation of health-related data for planning, implementation and evaluation of public health initiatives. Apart from the health system, social determinants of health include the circumstances in which people are born, grow up, live, work and age, and they go a long way to explaining health inequalities. A surveillance system of the social determinants of health requires a comprehensive and social overview of health. This paper analyses the importance of monitoring social determinants of health and health inequalities, and describes some relevant aspects concerning the implementation of surveillance during the data collection, compilation and analysis phases, as well as dissemination of information and evaluation of the surveillance system. It is important to have indicators from sources designed for this purpose, such as continuous records or periodic surveys, explicitly describing its limitations and strengths. The results should be published periodically in a communicative format that both enhances the public's ability to understand the problems that affect them, whilst at the same time empowering the population, with the ultimate goal of guiding health-related initiatives at different levels of intervention. Copyright © 2016 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Functional architecture of visual emotion recognition ability: A latent variable approach.

    Science.gov (United States)

    Lewis, Gary J; Lefevre, Carmen E; Young, Andrew W

    2016-05-01

    Emotion recognition has been a focus of considerable attention for several decades. However, despite this interest, the underlying structure of individual differences in emotion recognition ability has been largely overlooked and thus is poorly understood. For example, limited knowledge exists concerning whether recognition ability for one emotion (e.g., disgust) generalizes to other emotions (e.g., anger, fear). Furthermore, it is unclear whether emotion recognition ability generalizes across modalities, such that those who are good at recognizing emotions from the face, for example, are also good at identifying emotions from nonfacial cues (such as cues conveyed via the body). The primary goal of the current set of studies was to address these questions through establishing the structure of individual differences in visual emotion recognition ability. In three independent samples (Study 1: n = 640; Study 2: n = 389; Study 3: n = 303), we observed that the ability to recognize visually presented emotions is based on different sources of variation: a supramodal emotion-general factor, supramodal emotion-specific factors, and face- and within-modality emotion-specific factors. In addition, we found evidence that general intelligence and alexithymia were associated with supramodal emotion recognition ability. Autism-like traits, empathic concern, and alexithymia were independently associated with face-specific emotion recognition ability. These results (a) provide a platform for further individual differences research on emotion recognition ability, (b) indicate that differentiating levels within the architecture of emotion recognition ability is of high importance, and (c) show that the capacity to understand expressions of emotion in others is linked to broader affective and cognitive processes. (c) 2016 APA, all rights reserved).

  3. Resolution and drift measurements on the advanced photon source beam position monitor

    International Nuclear Information System (INIS)

    Chung, Y.; Kahana, E.

    1995-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N=2 n , n=1,2,...,11) . Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed. copyright 1995 American Institute of Physics

  4. Forest health monitoring: 2008 national technical report

    Science.gov (United States)

    Kevin M. Potter; Barbara L. Conkling

    2012-01-01

    The Forest Health Monitoring (FHM) Program’s annual national technical report has three objectives: (1) to present forest health status and trends from a national or a multi-State regional perspective using a variety of sources, (2) to introduce new techniques for analyzing forest health data, and (3) to report results of recently completed evaluation monitoring...

  5. Attention focussing and anomaly detection in real-time systems monitoring

    Science.gov (United States)

    Doyle, Richard J.; Chien, Steve A.; Fayyad, Usama M.; Porta, Harry J.

    1993-01-01

    In real-time monitoring situations, more information is not necessarily better. When faced with complex emergency situations, operators can experience information overload and a compromising of their ability to react quickly and correctly. We describe an approach to focusing operator attention in real-time systems monitoring based on a set of empirical and model-based measures for determining the relative importance of sensor data.

  6. Specific Abilities May Increment Psychometric g for High Ability Populations

    Science.gov (United States)

    2016-04-14

    tend to sort themselves into jobs that are commensurate with their ability level ( McCormick , DeNisi, & Staw, 1979; McCormick , Jeanneret, & Mecham...of Genetic Psychology, 153, 229-230. Specific abilities, g, & high ability populations 14 McCormick , E. J., DeNisi, A. S., & Shaw, J. B... McCormick , E. J., Jeanneret, P. R., & Mecham, R. C. (1972). A study of job characteristics and job dimensions as based on the Position Analysis Questionnaire

  7. Sequestration of soil nitrogen as tannin-protein complexes may improve the competitive ability of sheep laurel (Kalmia angustifolia) relative to black spruce (Picea mariana).

    Science.gov (United States)

    Joanisse, G D; Bradley, R L; Preston, C M; Bending, G D

    2009-01-01

    The role of litter tannins in controlling soil nitrogen (N) cycling may explain the competitive ability of Kalmia relative to black spruce (Picea mariana), although this has not been demonstrated experimentally. Here, the protein-precipitation capacities of purified tannins and leaf extracts from Kalmia and black spruce were compared. The resistance to degradation of tannin-protein precipitates from both species were compared by monitoring carbon (C) and N dynamics in humus amended with protein, purified tannins or protein-tannin precipitates. The purity of the precipitates was verified using solid-state (13)C nuclear magnetic resonance (NMR) spectra. The ability of mycorrhizal fungi associated with both species to grow on media amended with tannin-protein complexes as the principal N source was also compared. The protein precipitation capacity of Kalmia tannins was superior to those of black spruce. Humus amended with protein increased both mineral and microbial N, whereas humus amended with tannin-protein precipitates increased dissolved organic N. Mycorrhizal fungi associated with Kalmia showed better growth than those associated with black spruce when N was provided as tannin-protein precipitates. These data suggest that Kalmia litter increases the amount of soil N sequestered as tannin-protein complexes, which may improve the competitive ability of Kalmia relative to black spruce by favouring N uptake by mycorrhizas associated with the former.

  8. Do Executives Work Harder When They Are Monitored?

    NARCIS (Netherlands)

    H.G. Barkema (Harry)

    1995-01-01

    textabstractExplores whether eclectic theory leads to better predictions about internal control systems in corporations than does principal-agency theory. Ability of eclectic theory to explain various puzzles for principal-agent theory; Test of hypotheses on the use and effects of monitoring in

  9. Increase in Efficiency of Use of Pedestrian Radiation Portal Monitors

    Science.gov (United States)

    Solovev, D. B.; Merkusheva, A. E.

    2017-11-01

    Most international airports in the world use radiation portal monitors (RPM) for primary radiation control organization. During the exploitation pedestrian radiation portal monitors operators (in the Russian Federation it is a special subdivision of customs officials) have certain problems related to the search of an ionizing radiation source causing the alarm signal of a radiation monitor. Radiation portal monitors at standard (factory) settings have to find out the illegal moving of the radioisotopes moved by physical persons passing through a controlled zone and having a steady radiation by the gamma or neutron channel. The problem is that recently the number of the ownerships who underwent treatment or medical diagnostics with the use of radio pharmaceuticals considerably increased, i.e,. ownerships represent such an ionizing radiation source. The operator of the radiation portal monitor has to define very quickly whether the ownership is a violator (takes unsolved radioisotopes illegally) or is just a patient of the clinic who underwent treatment/diagnostics with the use of radio pharmaceuticals. The research showing the radioisotopes which are most often used in the medical purposes are given in article, it is offered to use the new software developed by the authors allowing the operator of the radiation portal monitor to define the location of the ownership which has such ionizing radiation source by the activity of radiation similar to the radiation from radio pharmaceuticals.

  10. Groundwater monitoring of hydraulic fracturing in California: Recommendations for permit-required monitoring

    Science.gov (United States)

    Esser, B. K.; Beller, H. R.; Carroll, S.; Cherry, J. A.; Jackson, R. B.; Jordan, P. D.; Madrid, V.; Morris, J.; Parker, B. L.; Stringfellow, W. T.; Varadharajan, C.; Vengosh, A.

    2015-12-01

    California recently passed legislation mandating dedicated groundwater quality monitoring for new well stimulation operations. The authors provided the State with expert advice on the design of such monitoring networks. Factors that must be considered in designing a new and unique groundwater monitoring program include: Program design: The design of a monitoring program is contingent on its purpose, which can range from detection of individual well leakage to demonstration of regional impact. The regulatory goals for permit-required monitoring conducted by operators on a well-by-well basis will differ from the scientific goals of a regional monitoring program conducted by the State. Vulnerability assessment: Identifying factors that increase the probability of transport of fluids from the hydrocarbon target zone to a protected groundwater zone enables the intensity of permit-required monitoring to be tiered by risk and also enables prioritization of regional monitoring of groundwater basins based on vulnerability. Risk factors include well integrity; proximity to existing wellbores and geologic features; wastewater disposal; vertical separation between the hydrocarbon and groundwater zones; and site-specific hydrogeology. Analyte choice: The choice of chemical analytes in a regulatory monitoring program is guided by the goals of detecting impact, assuring public safety, preventing resource degradation, and minimizing cost. Balancing these goals may be best served by tiered approach in which targeted analysis of specific chemical additives is triggered by significant changes in relevant but more easily analyzed constituents. Such an approach requires characterization of baseline conditions, especially in areas with long histories of oil and gas development. Monitoring technology: Monitoring a deep subsurface process or a long wellbore is more challenging than monitoring a surface industrial source. The requirement for monitoring multiple groundwater aquifers across

  11. Acoustic Monitoring of the Arctic Ice Cap

    Science.gov (United States)

    Porter, D. L.; Goemmer, S. A.; Chayes, D. N.

    2012-12-01

    Introduction The monitoring of the Arctic Ice Cap is important economically, tactically, and strategically. In the scenario of ice cap retreat, new paths of commerce open, e.g. waterways from Northern Europe to the Far East. Where ship-going commerce is conducted, the U.S. Navy and U.S. Coast Guard have always stood guard and been prepared to assist from acts of nature and of man. It is imperative that in addition to measuring the ice from satellites, e.g. Icesat, that we have an ability to measure the ice extent, its thickness, and roughness. These parameters play an important part in the modeling of the ice and the processes that control its growth or shrinking and its thickness. The proposed system consists of three subsystems. The first subsystem is an acoustic source, the second is an array of geophones and the third is a system to supply energy and transmit the results back to the analysis laboratory. The subsystems are described below. We conclude with a plan on how to tackle this project and the payoff to the ice cap modeler and hence the users, i.e. commerce and defense. System Two historically tested methods to generate a large amplitude multi-frequency sound source include explosives and air guns. A new method developed and tested by the University of Texas, ARL is a combustive Sound Source [Wilson, et al., 1995]. The combustive sound source is a submerged combustion chamber that is filled with the byproducts of the electrolysis of sea water, i.e. Hydrogen and Oxygen, an explosive mixture which is ignited via a spark. Thus, no additional compressors, gases, or explosives need to be transported to the Arctic to generate an acoustic pulse capable of the sediment and the ice. The second subsystem would be geophones capable of listening in the O(10 Hz) range and transmitting that data back to the laboratory. Thus two single arrays of geophones arranged orthogonal to each other with a range of 1000's of kilometers and a combustive sound source where the two

  12. Uncertainty of dustfall monitoring results

    Directory of Open Access Journals (Sweden)

    Martin A. van Nierop

    2017-06-01

    Full Text Available Fugitive dust has the ability to cause a nuisance and pollute the ambient environment, particularly from human activities including construction and industrial sites and mining operations. As such, dustfall monitoring has occurred for many decades in South Africa; little has been published on the repeatability, uncertainty, accuracy and precision of dustfall monitoring. Repeatability assesses the consistency associated with the results of a particular measurement under the same conditions; the consistency of the laboratory is assessed to determine the uncertainty associated with dustfall monitoring conducted by the laboratory. The aim of this study was to improve the understanding of the uncertainty in dustfall monitoring; thereby improving the confidence in dustfall monitoring. Uncertainty of dustfall monitoring was assessed through a 12-month study of 12 sites that were located on the boundary of the study area. Each site contained a directional dustfall sampler, which was modified by removing the rotating lid, with four buckets (A, B, C and D installed. Having four buckets on one stand allows for each bucket to be exposed to the same conditions, for the same period of time; therefore, should have equal amounts of dust deposited in these buckets. The difference in the weight (mg of the dust recorded from each bucket at each respective site was determined using the American Society for Testing and Materials method D1739 (ASTM D1739. The variability of the dust would provide the confidence level of dustfall monitoring when reporting to clients.

  13. Recognition memory, self-other source memory, and theory-of-mind in children with autism spectrum disorder.

    Science.gov (United States)

    Lind, Sophie E; Bowler, Dermot M

    2009-09-01

    This study investigated semantic and episodic memory in autism spectrum disorder (ASD), using a task which assessed recognition and self-other source memory. Children with ASD showed undiminished recognition memory but significantly diminished source memory, relative to age- and verbal ability-matched comparison children. Both children with and without ASD showed an "enactment effect", demonstrating significantly better recognition and source memory for self-performed actions than other-person-performed actions. Within the comparison group, theory-of-mind (ToM) task performance was significantly correlated with source memory, specifically for other-person-performed actions (after statistically controlling for verbal ability). Within the ASD group, ToM task performance was not significantly correlated with source memory (after controlling for verbal ability). Possible explanations for these relations between source memory and ToM are considered.

  14. Language mastery, narrative abilities and oral expression abilities in ...

    African Journals Online (AJOL)

    The importance of language and language mastery for science learning has been the object of extensive investigation in recent decades, leading to ample recognition. However, specific focus on the role of narrative abilities is still scarce. This work focuses on the relevance of narrative abilities for chemistry learning.

  15. Source-critical studies in Luke-Acts: Implications for understanding ...

    African Journals Online (AJOL)

    ), focusing on Luke's use of the oral Gospel he internalised during his kerygma performance, to demonstrate how an author's use of his sources in a literature is dialogically governed by his rhetorical goal and his ability to manage his sources.

  16. Intrabeam scattering studies at the Swiss light source

    CERN Document Server

    Antoniou, F; Aiba, M; Boege, M; Milas, N; Streun, A; Demma, T

    2012-01-01

    The target parameters of modern ultra-low emittance rings are entering into a regime where Intra-beam Scattering (IBS) becomes important and, in the case of linear collider damping rings, even a limitation for the delivered emittances. The Swiss Light Source (SLS) storage ring, as it has achieved a vertical geometrical emittance of around 1 pm at 2.4 GeV [1], and it has the ability to run at even lower energies, and the availability of emittance monitoring diagnostics, is an ideal testbed for IBS studies. Simulations using the classical IBS theories and tracking codes are undertaken in order to explore the possibilities and limitations for IBS measurements at the SLS. In this respect, comparison between the theories and codes is first discussed. The dependence of the output emittances, taking into account the effect of IBS, with respect to energy, bunch charge and zero current vertical and longitudinal emittance is also studied, in order to define the regimes where the IBS effect can be significant. First mea...

  17. Open Source Analysis in Support to Nonproliferation Monitoring and Verification Activities: Using the New Media to Derive Unknown New Information

    International Nuclear Information System (INIS)

    Pabian, F.; Renda, G.; Jungwirth, R.; Kim, L.; Wolfart, E.; Cojazzi, G.G.M.; )

    2015-01-01

    This paper will describe evolving techniques that leverage freely available open source social media venues, sometimes referred to as the ''New Media,'' together with geospatial tools and commercial satellite imagery (with its ever improving spatial, spectral, and temporal resolutions), to expand the existing nuclear non-proliferation knowledge base by way of a review of some recent exemplar cases. The application of such techniques can enhance more general data mining, as those techniques can be more directly tailored to IAEA Safeguards monitoring and other non-proliferation verification activities to improve the possibility of the remote detection of undeclared nuclear related facilities and/or activities. As part of what might be called the new ''Societal Verification'' regime, these techniques have enlisted either the passive or active involvement of interested parties (NGOs, academics, and even hobbyists) using open sources and collaboration networks together with previously highlighted geospatial visualization tools and techniques. This paper will show how new significant, and unprecedented, information discoveries have already been made (and published in open source) in the last four years, i.e., since the last IAEA Safeguards Symposium. With respect to the possibility of soliciting active participation (e.g., ''crowd-sourcing'') via social media, one can envision scenarios (one example from open source will be provided) whereby a previously unknown nuclear related facility could be identified or located through the online posting of reports, line drawings, and/or ground photographs. Nonetheless, these techniques should not be viewed as a panacea, as examples of both deception and human error will also be provided. This paper will highlight the use of these remote-means of discovery techniques, and how they have shed entirely new light on important nuclear non-proliferation relevant issues in

  18. Automated classification of seismic sources in a large database: a comparison of Random Forests and Deep Neural Networks.

    Science.gov (United States)

    Hibert, Clement; Stumpf, André; Provost, Floriane; Malet, Jean-Philippe

    2017-04-01

    In the past decades, the increasing quality of seismic sensors and capability to transfer remotely large quantity of data led to a fast densification of local, regional and global seismic networks for near real-time monitoring of crustal and surface processes. This technological advance permits the use of seismology to document geological and natural/anthropogenic processes (volcanoes, ice-calving, landslides, snow and rock avalanches, geothermal fields), but also led to an ever-growing quantity of seismic data. This wealth of seismic data makes the construction of complete seismicity catalogs, which include earthquakes but also other sources of seismic waves, more challenging and very time-consuming as this critical pre-processing stage is classically done by human operators and because hundreds of thousands of seismic signals have to be processed. To overcome this issue, the development of automatic methods for the processing of continuous seismic data appears to be a necessity. The classification algorithm should satisfy the need of a method that is robust, precise and versatile enough to be deployed to monitor the seismicity in very different contexts. In this study, we evaluate the ability of machine learning algorithms for the analysis of seismic sources at the Piton de la Fournaise volcano being Random Forest and Deep Neural Network classifiers. We gather a catalog of more than 20,000 events, belonging to 8 classes of seismic sources. We define 60 attributes, based on the waveform, the frequency content and the polarization of the seismic waves, to parameterize the seismic signals recorded. We show that both algorithms provide similar positive classification rates, with values exceeding 90% of the events. When trained with a sufficient number of events, the rate of positive identification can reach 99%. These very high rates of positive identification open the perspective of an operational implementation of these algorithms for near-real time monitoring of

  19. Energy Monitoring

    DEFF Research Database (Denmark)

    Hansen, Claus T.; Madsen, Dines; Christiensen, Thomas

    Energy measurement has become an important aspect of our daily lives since we have learned that energy consumption, is one of the main source of global warming. Measuring instruments varies from a simple watt-meter to more sophisticated microprocessor control devices. The negative effects...... that fossil fuels induce on our environment has forced us to research renewable energy such as sunlight, wind etc. This new environmental awareness has also helped us to realize the importance of monitoring and controlling our energy use. The main purpose in this research is to introduce a more sophisticated...... but affordable way to monitor energy consumption of individuals or groups of home appliances. By knowing their consumption the utilization can be regulated for more efficient use. A prototype system has been constructed to demonstrate our idea....

  20. Towards innovative roadside monitoring

    Science.gov (United States)

    Ojha, G.; Appel, E.; Magiera, T.

    2012-04-01

    Soil contamination along roadsides is an important factor of anthropogenic point source pollution. Climatic and traffic-specific factors influence the amount and characteristics of pollution emitted and deposited in the roadside soil. In our present study we focus on monitoring typical traffic pollutants (heavy metals HM, platinum group elements, polycyclic hydrocarbons PAH), and investigate the use of magnetic parameters, especially magnetic susceptibility (MS) as proxy. Monitoring plots were installed along roadside in areas with different climatic conditions and different traffic-specific activities (traffic density and speed, vehicle types, abrasion of tires, brake linings, petrol/diesel compounds and road maintenance). For monitoring we removed 10-15 cm of top soil at 1 m distance from the roadside edge and placed 30 plastic boxes there filled with clean quartz sand, to be sampled after regular intervals within two years. Preliminary data from the first year of monitoring are presented. Magnetic results revealed that a coarse grained magnetite-like phase is responsible for the enhancement of magnetic concentration. The mass-specific MS and concentration of pollutants (HM, PAH) all show a significant increase with time, however, there are obviously also seasonal and site-dependent effects which lead to more stable values over several months or even some decrease in the upper few cm due to migration into depth. Source identification indicates that the accumulated PAHs are primarily emissions from traffic. In order to be able to discriminate in between different kinds of transport and deposition (surface run off from the road and neighbouring soil material, splash water, air transport), we additionally established pillars at the roadside with clean quartz sampling boxes at different heights (surface, 0.5 m, 2 m). As a first surprising result we observed that the increase in the boxes at surface is not necessarily higher than at 0.5 m height. The results from our

  1. Proprioceptive Ability of Fencing and Table Tennis Practioners

    Directory of Open Access Journals (Sweden)

    Bańkosz Ziemowit

    2014-09-01

    Full Text Available Purpose. The aim of the study was to compare the spatial component of proprioceptive ability by reproducing a upper limb movement typical in table tennis and fencing. Methods. The research comprised 41 young males of which 12 were table tennis players, 14 fencers, and 15 not involved in any competitive sports as a control. The experiment was based on assessing the precision of pronation and supination of the forearm at the elbow joint in recreating a set movement range by use of a goniometer. Results and conclusions. The results point to a higher level of proprioceptive ability in fencers and table tennis players than the control group but only in respect to the tasks executed with the dominant limb. This is inferred to be the result from the specific character of both sports (i.e. the intensive use of one limb and the consequent laterality of that limb causing higher sensitivity and proprioception. This may provide a link between swordplay, table tennis, and the level of proprioception. The research methodology used herein may be useful in monitoring fencing training. Although not unequivocally statistically significant, the results indicate the potential for further research in this area.

  2. 77 FR 64244 - Revision to Ambient Nitrogen Dioxide Monitoring Requirements

    Science.gov (United States)

    2012-10-19

    ... characterization of NO 2 exposure for susceptible and vulnerable populations.\\3\\ The EPA Regional Administrators... demands of funding other new and expanded monitoring networks, including the source and population lead... NO 2 monitors which are the second near-road NO 2 monitor in any CBSA with a population of 2,500,000...

  3. Stack Monitor Operating Experience Review

    International Nuclear Information System (INIS)

    Cadwallader, L.C.; Bruyere, S.A.

    2009-01-01

    Stack monitors are used to sense radioactive particulates and gases in effluent air being vented from rooms of nuclear facilities. These monitors record the levels and types of effluents to the environment. This paper presents the results of a stack monitor operating experience review of the U.S. Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS) database records from the past 18 years. Regulations regarding these monitors are briefly described. Operating experiences reported by the U.S. DOE and in engineering literature sources were reviewed to determine the strengths and weaknesses of these monitors. Electrical faults, radiation instrumentation faults, and human errors are the three leading causes of failures. A representative 'all modes' failure rate is 1E-04/hr. Repair time estimates vary from an average repair time of 17.5 hours (with spare parts on hand) to 160 hours (without spare parts on hand). These data should support the use of stack monitors in any nuclear facility, including the National Ignition Facility and the international ITER project.

  4. Unified Monitoring Architecture for IT and Grid Services

    Science.gov (United States)

    Aimar, A.; Aguado Corman, A.; Andrade, P.; Belov, S.; Delgado Fernandez, J.; Garrido Bear, B.; Georgiou, M.; Karavakis, E.; Magnoni, L.; Rama Ballesteros, R.; Riahi, H.; Rodriguez Martinez, J.; Saiz, P.; Zolnai, D.

    2017-10-01

    This paper provides a detailed overview of the Unified Monitoring Architecture (UMA) that aims at merging the monitoring of the CERN IT data centres and the WLCG monitoring using common and widely-adopted open source technologies such as Flume, Elasticsearch, Hadoop, Spark, Kibana, Grafana and Zeppelin. It provides insights and details on the lessons learned, explaining the work performed in order to monitor the CERN IT data centres and the WLCG computing activities such as the job processing, data access and transfers, and the status of sites and services.

  5. Fine Resolution Air Quality Monitoring from a Small Satellite: CHRIS/PROBA

    Directory of Open Access Journals (Sweden)

    Man Sing Wong

    2008-11-01

    Full Text Available Current remote sensing techniques fail to address the task of air quality monitoring over complex regions where multiple pollution sources produce high spatial variability. This is due to a lack of suitable satellite-sensor combinations and appropriate aerosol optical thickness (AOT retrieval algorithms. The new generation of small satellites, with their lower costs and greater flexibility has the potential to address this problem, with customised platform-sensor combinations dedicated to monitoring single complex regions or mega-cities. This paper demonstrates the ability of the European Space Agency’s small satellite sensor CHRIS/PROBA to provide reliable AOT estimates at a spatially detailed level over Hong Kong, using a modified version of the dense dark vegetation (DDV algorithm devised for MODIS. Since CHRIS has no middle-IR band such as the MODIS 2,100 nm band which is transparent to fine aerosols, the longest waveband of CHRIS, the 1,019 nm band was used to approximate surface reflectance, by the subtraction of an offset derived from synchronous field reflectance spectra. Aerosol reflectance in the blue and red bands was then obtained from the strong empirical relationship observed between the CHRIS 1,019 nm, and the blue and red bands respectively. AOT retrievals for three different dates were shown to be reliable, when compared with AERONET and Microtops II sunphotometers, and a Lidar, as well as air quality data at ground stations. The AOT images exhibited considerable spatial variability over the 11 x 11km image area and were able to indicate both local and long distance sources.

  6. The Chandra Source Catalog: Source Properties and Data Products

    Science.gov (United States)

    Rots, Arnold; Evans, Ian N.; Glotfelty, Kenny J.; Primini, Francis A.; Zografou, Panagoula; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Gibbs, Danny G., II; Grier, John D.; Hain, Roger; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.

    2009-09-01

    The Chandra Source Catalog (CSC) is breaking new ground in several areas. There are two aspects that are of particular interest to the users: its evolution and its contents. The CSC will be a living catalog that becomes richer, bigger, and better in time while still remembering its state at each point in time. This means that users will be able to take full advantage of new additions to the catalog, while retaining the ability to back-track and return to what was extracted in the past. The CSC sheds the limitations of flat-table catalogs. Its sources will be characterized by a large number of properties, as usual, but each source will also be associated with its own specific data products, allowing users to perform mini custom analysis on the sources. Source properties fall in the spatial (position, extent), photometric (fluxes, count rates), spectral (hardness ratios, standard spectral fits), and temporal (variability probabilities) domains, and are all accompanied by error estimates. Data products cover the same coordinate space and include event lists, images, spectra, and light curves. In addition, the catalog contains data products covering complete observations: event lists, background images, exposure maps, etc. This work is supported by NASA contract NAS8-03060 (CXC).

  7. Sources of electron contamination for the Clinac-35 25-MV photon beam

    International Nuclear Information System (INIS)

    Petti, P.L.; Goodman, M.S.; Sisterson, J.M.; Biggs, P.J.; Gabriel, T.A.; Mohan, R.

    1983-01-01

    A detailed Monte Carlo approach has been employed to investigate the sources of electron contamination for the 25-MV photon beam generated by Varian's Clinac-35. Three sources of contamination were examined: (a) the flattening filter and beam monitor chamber, (b) the fixed primary collimators downstream from the monitor chamber and the adjustable photon jaws, and (c) the air volume separating the treatment head from the observation point. Five source-to-surface distances (SSDs) were considered for a single field size, 28 cm in diameter at 80 cm SSD. It was found that for small SSDs (80-100 cm), the dominant sources of electron contamination were the flattening filter and the beam monitor chamber which accounted for 70% of the unwanted electrons. Thirteen percent of the remaining electrons originated in the downstream primary collimators and the photon jaws, and 17% were produced in air. At larger SSDs, the fraction of unwanted electrons originating in air increased. At 400 cm SSD, 61% of the contaminating electrons present in the beam were produced in air, 34% originated in the flattening filter and beam monitor chamber, and 5% were due to interactions in the fixed collimators downstream from the monitor chamber and the adjustable photon jaws. These calculated results are substantiated by recent experiments

  8. A framework for air quality monitoring based on free public data and open source tools

    Science.gov (United States)

    Nikolov, Hristo; Borisova, Denitsa

    2014-10-01

    In the recent years more and more widely accepted by the Space agencies (e.g. NASA, ESA) is the policy toward provision of Earth observation (EO) data and end products concerning air quality especially in large urban areas without cost to researchers and SMEs. Those EO data are complemented by increasing amount of in-situ data also provided at no cost either from national authorities or having crowdsourced origin. This accessibility together with the increased processing capabilities of the free and open source software is a prerequisite for creation of solid framework for air modeling in support of decision making at medium and large scale. Essential part of this framework is web-based GIS mapping tool responsible for dissemination of the output generated. In this research an attempt is made to establish a running framework based solely on openly accessible data on air quality and on set of freely available software tools for processing and modeling taking into account the present status quo in Bulgaria. Among the primary sources of data, especially for bigger urban areas, for different types of gases and dust particles, noted should be the National Institute of Meteorology and Hydrology of Bulgaria (NIMH) and National System for Environmental Monitoring managed by Bulgarian Executive Environmental Agency (ExEA). Both authorities provide data for concentration of several gases just to mention CO, CO2, NO2, SO2, and fine suspended dust (PM10, PM2.5) on monthly (for some data on daily) basis. In the framework proposed these data will complement the data from satellite-based sensors such as OMI instrument aboard EOS-Aura satellite and from TROPOMI instrument payload for future ESA Sentinel-5P mission. Integral part of the framework is the modern map for the land use/land cover which is provided from EEA by initiative GIO Land CORINE. This map is also a product from EO data distributed at European level. First and above all, our effort is focused on provision to the

  9. Improving multi-tasking ability through action videogames.

    Science.gov (United States)

    Chiappe, Dan; Conger, Mark; Liao, Janet; Caldwell, J Lynn; Vu, Kim-Phuong L

    2013-03-01

    The present study examined whether action videogames can improve multi-tasking in high workload environments. Two groups with no action videogame experience were pre-tested using the Multi-Attribute Task Battery (MATB). It consists of two primary tasks; tracking and fuel management, and two secondary tasks; systems monitoring and communication. One group served as a control group, while a second played action videogames a minimum of 5 h a week for 10 weeks. Both groups returned for a post-assessment on the MATB. We found the videogame treatment enhanced performance on secondary tasks, without interfering with the primary tasks. Our results demonstrate action videogames can increase people's ability to take on additional tasks by increasing attentional capacity. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  10. The aging eyewitness: effects of age on face, delay, and source-memory ability.

    Science.gov (United States)

    Memon, Amina; Bartlett, James; Rose, Rachel; Gray, Colin

    2003-11-01

    As a way to examine the nature of age-related differences in lineup identification accuracy, young (16-33 years) and older (60-82 years) witnesses viewed two similar videotaped incidents, one involving a young perpetrator and the other involving an older perpetrator. The incidents were followed by two separate lineups, one for the younger perpetrator and one for the older perpetrator. When the test delay was short (35 min), the young and older witnesses performed similarly on the lineups, but when the tests were delayed by 1 week, the older witnesses were substantially less accurate. When the target was absent from the lineups, the older witnesses made more false alarm errors, particularly when the faces were young. When the target was present in the lineups, correct identifications by both young and older witnesses were positively correlated with a measure of source recollection derived from a separate face-recognition task. Older witnesses scored poorly on this measure, suggesting that source-recollection deficits are partially responsible for age-related differences in performance on the lineup task.

  11. Performance monitoring in the medial frontal cortex and related neural networks: From monitoring self actions to understanding others' actions.

    Science.gov (United States)

    Ninomiya, Taihei; Noritake, Atsushi; Ullsperger, Markus; Isoda, Masaki

    2018-04-27

    Action is a key channel for interacting with the outer world. As such, the ability to monitor actions and their consequences - regardless as to whether they are self-generated or other-generated - is of crucial importance for adaptive behavior. The medial frontal cortex (MFC) has long been studied as a critical node for performance monitoring in nonsocial contexts. Accumulating evidence suggests that the MFC is involved in a wide range of functions necessary for one's own performance monitoring, including error detection, and monitoring and resolving response conflicts. Recent studies, however, have also pointed to the importance of the MFC in performance monitoring under social conditions, ranging from monitoring and understanding others' actions to reading others' mental states, such as their beliefs and intentions (i.e., mentalizing). Here we review the functional roles of the MFC and related neural networks in performance monitoring in both nonsocial and social contexts, with an emphasis on the emerging field of a social systems neuroscience approach using macaque monkeys as a model system. Future work should determine the way in which the MFC exerts its monitoring function via interactions with other brain regions, such as the superior temporal sulcus in the mentalizing system and the ventral premotor cortex in the mirror system. Copyright © 2018. Published by Elsevier B.V.

  12. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  13. Using Item Response Theory to Develop Measures of Acquisitive and Protective Self-Monitoring From the Original Self-Monitoring Scale.

    Science.gov (United States)

    Wilmot, Michael P; Kostal, Jack W; Stillwell, David; Kosinski, Michal

    2017-07-01

    For the past 40 years, the conventional univariate model of self-monitoring has reigned as the dominant interpretative paradigm in the literature. However, recent findings associated with an alternative bivariate model challenge the conventional paradigm. In this study, item response theory is used to develop measures of the bivariate model of acquisitive and protective self-monitoring using original Self-Monitoring Scale (SMS) items, and data from two large, nonstudent samples ( Ns = 13,563 and 709). Results indicate that the new acquisitive (six-item) and protective (seven-item) self-monitoring scales are reliable, unbiased in terms of gender and age, and demonstrate theoretically consistent relations to measures of personality traits and cognitive ability. Additionally, by virtue of using original SMS items, previously collected responses can be reanalyzed in accordance with the alternative bivariate model. Recommendations for the reanalysis of archival SMS data, as well as directions for future research, are provided.

  14. Luminosity monitor at PEP

    International Nuclear Information System (INIS)

    Fox, J.D.; Franklin, M.E.B.

    1981-02-01

    The luminosity monitor system utilized by the MKII Detector and by the PEP operators is described. This system processes information from 56 photomultipliers and calculates independent luminosities for each of the 3 colliding bunches in PEP. Design considerations, measurement techniques, and sources of error in the luminosity measurement are discussed

  15. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C.; Bresson, J.; Chiffot, T.; Guillot, L. [Centre d`Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L`Energie Atomique, Tille (France)

    1997-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  16. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C; Bresson, J; Chiffot, T; Guillot, L [Centre d` Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L` Energie Atomique, Tille (France)

    1998-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  17. Monitoring and evaluation of duct emission and stationary sources of ceramic industries by SR-TXRF

    International Nuclear Information System (INIS)

    Moreira, Silvana; Fonseca, Roney Jose; Vives, Ana Elisa Sirito de

    2009-01-01

    The aim of this study was to monitor and evaluate the emission of metals from ducts and stationary sources in ceramic industries in the region of the ceramic centre of Santa Gertrudes in the state of Sao Paulo. There has been a growth of this industrial sector in recent years. This reflected upon the environment in this region which is responsible for 60% of ceramic tile floor production. From 2005 to 2006, samples of gases emitted by several ceramic companies in that region were collected. Metal concentration was determined through X-ray Fluorescence by Total Reflection with Synchrotron Radiation (SR-TXRF) technique. The analyses were carried out in the National Laboratory of Synchrotron Light (NLSL) and used a polychromatic beam of light to stimulate the samples and a hyper pure Germanic detector for the characteristic X-ray detection. The following elements were detected: Al, S, Cl, K, Ca, Fe, Cr, Mn, Ni, Cu, Zn and Pb. High concentrations of elements such as Chromium, Nickel and Lead were observed in the samples analyzed which presented values of concentrations higher than the ones permitted by legislation. (author)

  18. Monitoring and evaluation of duct emission and stationary sources of ceramic industries by SR-TXRF

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana; Fonseca, Roney Jose, E-mail: silvana@fec.unicamp.b [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo; Vives, Ana Elisa Sirito de, E-mail: aesvives@unimep.b [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo

    2009-07-01

    The aim of this study was to monitor and evaluate the emission of metals from ducts and stationary sources in ceramic industries in the region of the ceramic centre of Santa Gertrudes in the state of Sao Paulo. There has been a growth of this industrial sector in recent years. This reflected upon the environment in this region which is responsible for 60% of ceramic tile floor production. From 2005 to 2006, samples of gases emitted by several ceramic companies in that region were collected. Metal concentration was determined through X-ray Fluorescence by Total Reflection with Synchrotron Radiation (SR-TXRF) technique. The analyses were carried out in the National Laboratory of Synchrotron Light (NLSL) and used a polychromatic beam of light to stimulate the samples and a hyper pure Germanic detector for the characteristic X-ray detection. The following elements were detected: Al, S, Cl, K, Ca, Fe, Cr, Mn, Ni, Cu, Zn and Pb. High concentrations of elements such as Chromium, Nickel and Lead were observed in the samples analyzed which presented values of concentrations higher than the ones permitted by legislation. (author)

  19. FACT. Flare alerts from blazar monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Dorner, Daniela [Universitaet Wuerzburg (Germany); Bretz, Thomas [RWTH Aachen (Germany); Collaboration: FACT-Collaboration

    2015-07-01

    One of the major goals of the First G-APD Cherenkov Telescope is the longterm monitoring of bright TeV blazars. For more than three years, FACT has observed the blazars Mrk 421 and Mrk 501 and a few other sources on a regular basis. To understand these highly variable objects, simultaneous data at different wavelengths are very useful. FACT is not only taking part in multi-wavelength campaigns, but also sending alerts to other instruments in case of enhanced flux, to study flares within the multi-wavelength frame. To send fast alerts, an automatic quick look analysis was set up on site. Once the data are written on disk, they are automatically processed, and the analysis results are published on a website where other observers can monitor the activity of the source in the very high energy band. In addition, alerts are sent in case the flux is higher than a certain predefined value. In 2014, more than five alerts have been sent. Results from three years of monitoring are presented.

  20. Reservoir stress from microseismic source mechanisms

    Czech Academy of Sciences Publication Activity Database

    Staněk, František; Jechumtálová, Z.; Eisner, L.

    2015-01-01

    Roč. 34, č. 8 (2015), od 890 do 893, 895 ISSN 1070-485X Institutional support: RVO:67985891 Keywords : microseismic monitoring * source mechanisms * stress Subject RIV: DC - Siesmology, Volcanology, Earth Structure

  1. Technological advances in perioperative monitoring: Current concepts and clinical perspectives.

    Science.gov (United States)

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.

  2. A Novel Infrared Gas Monitor

    Science.gov (United States)

    Wang, Yingding; Zhong, Hongjie

    2000-03-01

    In the paper a novel non-dispersive infrared(IR) gas monitor is described.It is based on the principle that certain gases absorb IR radiation at specific(and often unique) wavelengths.Conventional devices typically include several primary components:a broadband source, usually an incandescent filament,a rotating chopper shutter,a narrow-band filter,a sample tube and a detector. We have developed a number of IR light emitting diodes(LED) having narrow optical bandwidths and which can be intensity modulated by electrical means,for example InAsSbP(4.2 micron)LED.The IR LED can thus replace the thermal source,narrow-band filter and chopper assembly of the conventional IR gas monitor,yielding a solid state,low- powered,compact and almost maintenance-free instrument with high sensitivity and stability and which free of the effects of mechanical vibration too. The detector used in the IR gas monitor is the solid-state detector,such as PbS,PbSe, InSb,HgCdTe,TGS,LT and PZT detector etc. The different configuration of the IR gas monitor is designed.For example,two-path version for measuring methane concentration by monitoring the 3.31 micron absorption band,it can eliminate the interference effects,such as to compensate for LED intensity changes caused by power and temperature variations,and for signal fluctuations due to changes in detector bias. we also have designed portable single-beam version without the sample tube.Its most primary advantage is very cheap(about cost USD 30 ).It measures carbon dioxide concentration by monitoring the 4.25 micron absorption band.Thought its precisions is low,it is used to control carbon dioxide concentration in the air in the green houses and plastic houses(there are about twenty millon one in the China).Because more carbon dioxide will increase the quanity of vegetable and flower production to a greatextent. It also is used in medical,sanitary and antiepidemic applications,such as hospital, store,hotel,cabin and ballroom etc. Key words

  3. Radiation source states on-line supervision system design and implementation based on RFID technology

    International Nuclear Information System (INIS)

    Yang Binhua; Ling Qiu; Yin Guoli; Yang Kun; Wan Xueping; Wang Kan

    2011-01-01

    It puts forward radiation source states on-line monitoring resolution based on RFID technology. Firstly, the system uses RFID in real-time transmission of the radiation dose rate, and monitors the radiation source states and dose rate of the surrounding environment on-line. Then it adopts regional wireless networking mode to construct enterprise level monitoring network, which resolves long-distance wiring problems. And then it uses GPRS wireless to transport the real-time data to the monitoring center and the government supervision department, By adopting randomly dynamic cording in display update every day, it strengthens the supervision of the radiation source. At last this system has been successful applied to a thickness gauge project, which verifies the feasibility and practicality is good. (authors)

  4. Glucose monitoring as a guide to diabetes management. Critical subject review.

    OpenAIRE

    Koch, B.

    1996-01-01

    PURPOSE: To encourage a balanced approach to blood glucose monitoring in diabetes by a critical review of the history, power and cost of glucose testing. DATA SOURCES: The Cambridge Data Base was searched and was supplemented by a random review of other relevant sources, including textbooks, company pamphlets, and laboratory manuals. STUDY SELECTION: Keywords used were "glucosuria diagnosis," "blood glucose self-monitoring," "glycosylated hemoglobin," and "fructosamine" for the 10-year period...

  5. Identification and Characterization of Oleaginous Yeast Isolated from Kefir and Its Ability to Accumulate Intracellular Fats in Deproteinated Potato Wastewater with Different Carbon Sources

    Directory of Open Access Journals (Sweden)

    Iwona Gientka

    2017-01-01

    Full Text Available The search for efficient oleaginous microorganisms, which can be an alternative to fossil fuels and biofuels obtained from oilseed crops, has been going on for many years. The suitability of microorganisms in this regard is determined by their ability to biosynthesize lipids with preferred fatty acid profile along with the concurrent utilization of energy-rich industrial waste. In this study, we isolated, characterized, and identified kefir yeast strains using molecular biology techniques. The yeast isolates identified were Candida inconspicua, Debaryomyces hansenii, Kluyveromyces marxianus, Kazachstania unispora, and Zygotorulaspora florentina. We showed that deproteinated potato wastewater, a starch processing industry waste, supplemented with various carbon sources, including lactose and glycerol, is a suitable medium for the growth of yeast, which allows an accumulation of over 20% of lipid substances in its cells. Fatty acid composition primarily depended on the yeast strain and the carbon source used, and, based on our results, most of the strains met the criteria required for the production of biodiesel. In particular, this concerns a significant share of saturated fatty acids, such as C16:0 and C18:0, and unsaturated fatty acids, such as C18:1 and C18:2. The highest efficiency in lipid biosynthesis exceeded 6.3 g L−1. Kazachstania unispora was able to accumulate the high amount of palmitoleic acid.

  6. Identification and Characterization of Oleaginous Yeast Isolated from Kefir and Its Ability to Accumulate Intracellular Fats in Deproteinated Potato Wastewater with Different Carbon Sources.

    Science.gov (United States)

    Gientka, Iwona; Kieliszek, Marek; Jermacz, Karolina; Błażejak, Stanisław

    2017-01-01

    The search for efficient oleaginous microorganisms, which can be an alternative to fossil fuels and biofuels obtained from oilseed crops, has been going on for many years. The suitability of microorganisms in this regard is determined by their ability to biosynthesize lipids with preferred fatty acid profile along with the concurrent utilization of energy-rich industrial waste. In this study, we isolated, characterized, and identified kefir yeast strains using molecular biology techniques. The yeast isolates identified were Candida inconspicua , Debaryomyces hansenii , Kluyveromyces marxianus , Kazachstania unispora , and Zygotorulaspora florentina . We showed that deproteinated potato wastewater, a starch processing industry waste, supplemented with various carbon sources, including lactose and glycerol, is a suitable medium for the growth of yeast, which allows an accumulation of over 20% of lipid substances in its cells. Fatty acid composition primarily depended on the yeast strain and the carbon source used, and, based on our results, most of the strains met the criteria required for the production of biodiesel. In particular, this concerns a significant share of saturated fatty acids, such as C16:0 and C18:0, and unsaturated fatty acids, such as C18:1 and C18:2. The highest efficiency in lipid biosynthesis exceeded 6.3 g L -1 . Kazachstania unispora was able to accumulate the high amount of palmitoleic acid.

  7. Identification and Characterization of Oleaginous Yeast Isolated from Kefir and Its Ability to Accumulate Intracellular Fats in Deproteinated Potato Wastewater with Different Carbon Sources

    Science.gov (United States)

    Kieliszek, Marek; Jermacz, Karolina; Błażejak, Stanisław

    2017-01-01

    The search for efficient oleaginous microorganisms, which can be an alternative to fossil fuels and biofuels obtained from oilseed crops, has been going on for many years. The suitability of microorganisms in this regard is determined by their ability to biosynthesize lipids with preferred fatty acid profile along with the concurrent utilization of energy-rich industrial waste. In this study, we isolated, characterized, and identified kefir yeast strains using molecular biology techniques. The yeast isolates identified were Candida inconspicua, Debaryomyces hansenii, Kluyveromyces marxianus, Kazachstania unispora, and Zygotorulaspora florentina. We showed that deproteinated potato wastewater, a starch processing industry waste, supplemented with various carbon sources, including lactose and glycerol, is a suitable medium for the growth of yeast, which allows an accumulation of over 20% of lipid substances in its cells. Fatty acid composition primarily depended on the yeast strain and the carbon source used, and, based on our results, most of the strains met the criteria required for the production of biodiesel. In particular, this concerns a significant share of saturated fatty acids, such as C16:0 and C18:0, and unsaturated fatty acids, such as C18:1 and C18:2. The highest efficiency in lipid biosynthesis exceeded 6.3 g L−1. Kazachstania unispora was able to accumulate the high amount of palmitoleic acid. PMID:29098157

  8. Low-cost wireless voltage & current grid monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hines, Jacqueline [SenSanna Inc., Arnold, MD (United States)

    2016-12-31

    This report describes the development and demonstration of a novel low-cost wireless power distribution line monitoring system. This system measures voltage, current, and relative phase on power lines of up to 35 kV-class. The line units operate without any batteries, and without harvesting energy from the power line. Thus, data on grid condition is provided even in outage conditions, when line current is zero. This enhances worker safety by detecting the presence of voltage and current that may appear from stray sources on nominally isolated lines. Availability of low-cost power line monitoring systems will enable widespread monitoring of the distribution grid. Real-time data on local grid operating conditions will enable grid operators to optimize grid operation, implement grid automation, and understand the impact of solar and other distributed sources on grid stability. The latter will enable utilities to implement eneygy storage and control systems to enable greater penetration of solar into the grid.

  9. Bunch by bunch beam monitoring in 3rd and 4th generation light sources by means of single crystal diamond detectors and quantum well devices

    Science.gov (United States)

    Antonelli, M.; Di Fraia, M.; Tallaire, A.; Achard, J.; Carrato, S.; Menk, R. H.; Cautero, G.; Giuressi, D.; Jark, W. H.; Biasiol, G.; Ganbold, T.; Oliver, K.; Callegari, C.; Coreno, M.; De Sio, A.; Pace, E.

    2012-10-01

    New generation Synchrotron Radiation (SR) sources and Free Electron Lasers (FEL) require novel concepts of beam diagnostics to keep photon beams under surveillance, asking for simultaneous position and intensity monitoring. To deal with high power load and short time pulses provided by these sources, novel materials and methods are needed for the next generation BPMs. Diamond is a promising material for the production of semitransparent in situ X-ray BPMs withstanding the high dose rates of SR rings and high energy FELs. We report on the development of freestanding, single crystal CVD diamond detectors. Performances in both low and radio frequency SR beam monitoring are presented. For the former, sensitivity deviation was found to be approximately 2%; a 0.05% relative precision in the intensity measurements and a 0.1-μm precision in the position encoding have been estimated. For the latter, single-shot characterizations revealed sub-nanosecond rise-times and spatial precisions below 6 μm, which allowed bunch-by-bunch monitoring in multi-bunch operation. Preliminary measurements at the Fermi FEL have been performed with this detector, extracting quantitative intensity and position information for FEL pulses (~ 100 fs, energy 12 ÷ 60 eV), with a long-term spatial precision of about 85 μm results on FEL radiation damages are also reported. Due to their direct, low-energy band gap, InGaAs quantum well devices too may be used as fast detectors for photons ranging from visible to X-ray. Results are reported which show the capability of a novel InGaAs/InAlAs device to detect intensity and position of 100-fs-wide laser pulses.

  10. Blind source deconvolution for deep Earth seismology

    Science.gov (United States)

    Stefan, W.; Renaut, R.; Garnero, E. J.; Lay, T.

    2007-12-01

    We present an approach to automatically estimate an empirical source characterization of deep earthquakes recorded teleseismically and subsequently remove the source from the recordings by applying regularized deconvolution. A principle goal in this work is to effectively deblur the seismograms, resulting in more impulsive and narrower pulses, permitting better constraints in high resolution waveform analyses. Our method consists of two stages: (1) we first estimate the empirical source by automatically registering traces to their 1st principal component with a weighting scheme based on their deviation from this shape, we then use this shape as an estimation of the earthquake source. (2) We compare different deconvolution techniques to remove the source characteristic from the trace. In particular Total Variation (TV) regularized deconvolution is used which utilizes the fact that most natural signals have an underlying spareness in an appropriate basis, in this case, impulsive onsets of seismic arrivals. We show several examples of deep focus Fiji-Tonga region earthquakes for the phases S and ScS, comparing source responses for the separate phases. TV deconvolution is compared to the water level deconvolution, Tikenov deconvolution, and L1 norm deconvolution, for both data and synthetics. This approach significantly improves our ability to study subtle waveform features that are commonly masked by either noise or the earthquake source. Eliminating source complexities improves our ability to resolve deep mantle triplications, waveform complexities associated with possible double crossings of the post-perovskite phase transition, as well as increasing stability in waveform analyses used for deep mantle anisotropy measurements.

  11. Selection and Management of Open Source Software in Libraries

    OpenAIRE

    Vimal Kumar, V.

    2007-01-01

    Open source software was a revolutionary concept among computer programmers and users. To a certain extent open source solutions could provide an alternative solution to costly commercial software. Open source software is, software that users have the ability to run, copy, distribute, study, change, share and improve for any purpose. Open source library software’s does not need the initial cost of commercial software and enables libraries to have greater control over their working environmen...

  12. Phosphate-Solubilizing and -Mineralizing Abilities of Bacteria Isolated from Soils

    Institute of Scientific and Technical Information of China (English)

    TAO Guang-Can; TIAN Shu-Jun; CAI Miao-Ying; XIE Guang-Hui

    2008-01-01

    Microorganisms capable of solubilizing and mineralizing phosphorus (P) pools in soils are considered vital in promoting P bioavailability. The study was conducted to screen and isolate inorganic P-solubilizing bacteria (IPSB) and organic P-mineralizing bacteria (OPMB) in soils taken from subtropical flooded and temperate non-flooded soils, and to compare inorganic P-solubilizing and organic P-solubilizing abilities between IPSB and OPMB. Ten OPMB strains were isolated and identified as Bacillus cereus and Bacillus megaterium, and five IPSB strains as B. megaterium, Burkholderia caryophylli,Pseudomonas ciehorii, and Pseudomonas syringae. P-solubilizing and -mineralizing abilities of the strains were measured using the methods taking cellular P into account. The IPSB strains exhibited inorganic P-sohibilizing abilities ranging between 25.4-41.7 μg P mL-1 and organic P-mineralizing abilities between 8.2-17.8 μg P mL-1. Each of the OPMB strains also exhibited both solubilizing and mineralizing abilities varying from 4.4 to 26.5 μg P mL-1 and from 13.8 to 62.8 μg P mL-1, respectively. For both IPSB and OPMB strains, most of the P mineralized from the organic P source was incorporated into the bacterial cells as cellular P. A significantly negative linear correlation (P < 0.05) was found between culture pH and P solubilized from inorganic P by OPMB strains. The results suggested that P solubilization and mineralization could coexist in the same bacterial strain.

  13. Plasma diagnostic tools for optimizing negative hydrogen ion sources

    International Nuclear Information System (INIS)

    Fantz, U.; Falter, H.D.; Franzen, P.; Speth, E.; Hemsworth, R.; Boilson, D.; Krylov, A.

    2006-01-01

    The powerful diagnostic tool of optical emission spectroscopy is used to measure the plasma parameters in negative hydrogen ion sources based on the surface mechanism. Results for electron temperature, electron density, atomic-to-molecular hydrogen density ratio, and gas temperature are presented for two types of sources, a rf source and an arc source, which are currently under development for a neutral beam heating system of ITER. The amount of cesium in the plasma volume is obtained from cesium radiation: the Cs neutral density is five to ten orders of magnitude lower than the hydrogen density and the Cs ion density is two to three orders of magnitude lower than the electron density in front of the grid. It is shown that monitoring of cesium lines is very useful for monitoring the cesium balance in the source. From a line-ratio method negative ion densities are determined. In a well-conditioned source the negative ion density is of the same order of magnitude as the electron density and correlates with extracted current densities

  14. Establishing a Multi-spatial Wireless Sensor Network to Monitor Nitrate Concentrations in Soil Moisture

    Science.gov (United States)

    Haux, E.; Busek, N.; Park, Y.; Estrin, D.; Harmon, T. C.

    2004-12-01

    The use of reclaimed wastewater for irrigation in agriculture can be a significant source of nutrients, in particular nitrogen species, but its use raises concern for groundwater, riparian, and water quality. A 'smart' technology would have the ability to measure wastewater nutrients as they enter the irrigation system, monitor their transport in situ and optimally control inputs with little human intervention, all in real-time. Soil heterogeneity and economic issues require, however, a balance between cost and the spatial and temporal scales of the monitoring effort. Therefore, a wireless and embedded sensor network, deployed in the soil vertically across the horizon, is capable of collecting, processing, and transmitting sensor data. The network consists of several networked nodes or 'pylons', each outfitted with an array of sensors measuring humidity, temperature, precipitation, soil moisture, and aqueous nitrate concentrations. Individual sensor arrays are controlled by a MICA2 mote (Crossbow Technology Inc., San Jose, CA) programmed with TinyOS (University of California, Berkeley, CA) and a Stargate (Crossbow Technology Inc., San Jose, CA) base-station capable of GPRS for data transmission. Results are reported for the construction and testing of a prototypical pylon at the benchtop and in the field.

  15. A source classification framework supporting pollutant source mapping, pollutant release prediction, transport and load forecasting, and source control planning for urban environments

    DEFF Research Database (Denmark)

    Lützhøft, Hans-Christian Holten; Donner, Erica; Wickman, Tonie

    2012-01-01

    for this purpose. Methods Existing source classification systems were examined by a multidisciplinary research team, and an optimised SCF was developed. The performance and usability of the SCF were tested using a selection of 25 chemicals listed as priority pollutants in Europe. Results The SCF is structured...... in the form of a relational database and incorporates both qualitative and quantitative source classification and release data. The system supports a wide range of pollution monitoring and management applications. The SCF functioned well in the performance test, which also revealed important gaps in priority...

  16. A new concept of efficient therapeutic drug monitoring using the high-resolution continuum source absorption spectrometry and the surface enhanced Raman spectroscopy

    Science.gov (United States)

    Xing, Yanlong; Fuss, Harald; Lademann, Jürgen; Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Patzelt, Alexa; Meinke, Martina C.; Jung, Sora; Esser, Norbert

    2018-04-01

    In this study, a new therapeutic drug monitoring approach has been tested based on the combination of CaF molecular absorption using high-resolution continuum source absorption spectrometry (HR-CSAS) and surface enhanced Raman spectroscopy (SERS). HR-CSAS with mini graphite tube was successfully tested for clinical therapeutic drug monitoring of the fluorine-containing drug capecitabine in sweat samples of cancer patients: It showed advantageous features of high selectivity (no interference from Cl), high sensitivity (characteristic mass of 0.1 ng at CaF 583.069 nm), low sample consumption (down to 30 nL) and fast measurement (no sample pretreatment and less than 1 min of responding time) in tracing the fluorine signal out of capecitabine. However, this technique has the disadvantage of the total loss of the drug's structure information after burning the sample at very high temperature. Therefore, a new concept of combining HR-CSAS with a non-destructive spectroscopic method (SERS) was proposed for the sensitive sensing and specific identification of capecitabine. We tested and succeed in obtaining the molecular characteristics of the metabolite of capecitabine (named 5-fluorouracil) by the non-destructive SERS technique. With the results shown in this work, it is demonstrated that the combined spectroscopic technique of HR-CSAS and SERS will be very useful in efficient therapeutic drug monitoring in the future.

  17. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes.

    Science.gov (United States)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009-2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100ngL(-1)). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ(18)O, δ(15)N and δ(34)S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100ngL(-1). The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ(15)N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with several

  18. Assessing Extension's Ability to Promote Family Forests as a Woody Biomass Feedstock in the Northeast United States

    Science.gov (United States)

    Germain, Rene' H.; Ghosh, Chandrani

    2013-01-01

    The study reported here surveyed Extension educators' awareness and knowledge of woody biomass energy and assessed their desire and ability to reach out to family forest owners-a critical feedstock source. The results indicate Extension educators are aware of the potential of woody biomass to serve as a renewable source of energy. Respondents…

  19. Remote monitoring: An implementation on the Gemini System

    International Nuclear Information System (INIS)

    Sheridan, R.; Ondrik, M.; Kadner, S.; Resnik, W.; Chitumbo, K.; Corbell, B.

    1996-01-01

    The Gemini System consists of a sophisticated, digital surveillance unit and a high performance review system. Due to the open architectural design of the Gemini System, it provides an excellent hardware and software platform to support remote monitoring. The present Gemini System provides the user with the following Remote Monitoring features, via a modem interface and powerful support software: state-of-health reporting, alarm reporting, and remote user interface. Future enhancements will contribute significantly to the Gemini''s ability to provide a broader spectrum of network interfaces and remote review

  20. Environmental monitoring to the sources of atmospheric emission by the Trad-MCN bioassay and analysis of the accumulative potential for uranium and fluoride

    International Nuclear Information System (INIS)

    Machado, Alessandra C.F.E.; Ramos, Monique M.B.; Alves, Edenise S.

    2009-01-01

    The biomonitoring of the atmospheric contamination constitutes important procedure for adoption of environmental control measures. Biological assays have been employed to evaluate genotoxic agents in the atmosphere. The Tradescantia-micronucleus (Trad-MCN) assay has been extensively used in environmental monitoring owing to its efficiency in the detection of chromosomic damages in cytological preparations of easy execution. In this study we tested the viability of use of Trad-MCN with Tradescantia pallida cv. Purpurea for environmental monitoring in the Experimental Center Aramar (CEA), in Ipero - SP and its leaf accumulation capacity. The plants were exposed in situ, in flower-beds or flowerpots, established close to the sources of atmospheric emission. The bioassay was accomplished according to the usual protocol. The micronucleus frequencies were compared using the variance Kruskal-Wallis test. The obtained results indicated that the biomonitoring model adopted was not the ideal for the CEA, considering that the plant suffered the influence of climatic condition. However the plant showed to have accumulative potential for uranium. (author)