WorldWideScience

Sample records for source location determination

  1. Investigation of source location determination from Magsat magnetic anomalies: The Euler method approach

    Science.gov (United States)

    Ravat, Dhananjay

    1996-01-01

    The applicability of the Euler method of source location determination was investigated on several model situations pertinent to satellite-data scale situations as well as Magsat data of Europe. Our investigations enabled us to understand the end-member cases for which the Euler method will work with the present satellite magnetic data and also the cases for which the assumptions implicit in the Euler method will not be met by the present satellite magnetic data. These results have been presented in one invited lecture at the Indo-US workshop on Geomagnetism in Studies of the Earth's Interior in August 1994 in Pune, India, and at one presentation at the 21st General Assembly of the IUGG in July 1995 in Boulder, CO. A new method, called Anomaly Attenuation Rate (AAR) Method (based on the Euler method), was developed during this study. This method is scale-independent and is appropriate to locate centroids of semi-compact three dimensional sources of gravity and magnetic anomalies. The method was presented during 1996 Spring AGU meeting and a manuscript describing this method is being prepared for its submission to a high-ranking journal. The grant has resulted in 3 papers and presentations at national and international meetings and one manuscript of a paper (to be submitted shortly to a reputable journal).

  2. Accuracy evaluation of distance inverse square law in determining virtual electron source location in Siemens Primus linac.

    Science.gov (United States)

    Douk, Hamid Shafaei; Aghamiri, Mahmoud Reza; Ghorbani, Mahdi; Farhood, Bagher; Bakhshandeh, Mohsen; Hemmati, Hamid Reza

    2018-01-01

    The aim of this study is to evaluate the accuracy of the inverse square law (ISL) method for determining location of virtual electron source ( S Vir ) in Siemens Primus linac. So far, different experimental methods have presented for determining virtual and effective electron source location such as Full Width at Half Maximum (FWHM), Multiple Coulomb Scattering (MCS), and Multi Pinhole Camera (MPC) and Inverse Square Law (ISL) methods. Among these methods, Inverse Square Law is the most common used method. Firstly, Siemens Primus linac was simulated using MCNPX Monte Carlo code. Then, by using dose profiles obtained from the Monte Carlo simulations, the location of S Vir was calculated for 5, 7, 8, 10, 12 and 14 MeV electron energies and 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm and 25 cm × 25 cm field sizes. Additionally, the location of S Vir was obtained by the ISL method for the mentioned electron energies and field sizes. Finally, the values obtained by the ISL method were compared to the values resulted from Monte Carlo simulation. The findings indicate that the calculated S Vir values depend on beam energy and field size. For a specific energy, with increase of field size, the distance of S Vir increases for most cases. Furthermore, for a special applicator, with increase of electron energy, the distance of S Vir increases for most cases. The variation of S Vir values versus change of field size in a certain energy is more than the variation of S Vir values versus change of electron energy in a certain field size. According to the results, it is concluded that the ISL method can be considered as a good method for calculation of S Vir location in higher electron energies (14 MeV).

  3. Source Location of Noble Gas Plumes

    International Nuclear Information System (INIS)

    Hoffman, I.; Ungar, K.; Bourgouin, P.; Yee, E.; Wotawa, G.

    2015-01-01

    In radionuclide monitoring, one of the most significant challenges from a verification or surveillance perspective is the source location problem. Modern monitoring/surveillance systems employ meteorological source reconstruction — for example, the Fukushima accident, CRL emissions analysis and even radon risk mapping. These studies usually take weeks to months to conduct, involving multidisciplinary teams representing meteorology; dispersion modelling; radionuclide sampling and metrology; and, when relevant, proper representation of source characteristics (e.g., reactor engineering expertise). Several different approaches have been tried in an attempt to determine useful techniques to apply to the source location problem and to develop rigorous methods that combine all potentially relevant observations and models to identify a most probable source location and size with uncertainties. The ultimate goal is to understand the utility and limitations of these techniques so they can transition from R&D to operational tools. (author)

  4. Characteristics and locations of sources

    International Nuclear Information System (INIS)

    Lahtinen, J.; Poellaenen, R.; Toivonen, H.

    1997-01-01

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were 60 Co, 137 Cs, 99m Tc and 192 Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au)

  5. Characteristics and locations of sources

    Energy Technology Data Exchange (ETDEWEB)

    Lahtinen, J.; Poellaenen, R.; Toivonen, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were {sup 60}Co, {sup 137}Cs, {sup 99m}Tc and {sup 192}Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au).

  6. Characteristics and locations of sources

    Energy Technology Data Exchange (ETDEWEB)

    Lahtinen, J; Poellaenen, R; Toivonen, H [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1998-12-31

    Ten artificial radiation sources were placed in the terrain in order to test the capability of airborne measuring teams to detect them. One of the sources was a line source, others were point sources (three of them collimated). The radionuclides used in the sources were {sup 60}Co, {sup 137}Cs, {sup 99m}Tc and {sup 192}Ir. The source activities ranged from about 26 MBq (one of the cobalt sources) to 0.56 TBq (iridium). (au).

  7. On the question of 3D seed reconstruction in prostate brachytherapy: the determination of x-ray source and film locations

    International Nuclear Information System (INIS)

    Zhang Mutian; Zaider, Marco; Worman, Michael; Cohen, Gilad

    2004-01-01

    Inaccuracy in seed placement during permanent prostate implants may lead to significant dosimetric deviations from the intended plan. In two recent publications (Todor et al 2002 Phys. Med. Biol. 47 2031-48, Todor et al 2003 Phys. Med. Biol. 48 1153-71), methodology was described for identifying intraoperatively the positions of seeds already implanted, thus allowing re-optimization of the treatment plan and correcting for such seed misplacement. Seed reconstruction is performed using fluoroscopic images and an important (and non-trivial) component of this approach is the ability to accurately determine the position of the gantry relative to the treatment volume. We describe the methodology for acquiring this information, based on the known geometry of six markers attached to the ultrasound probe. This method does not require the C-arm unit to be isocentric and films can be taken with the gantry set at any arbitrary position. This is significant because the patient positioning on the operating table (in the lithotomy position) restricts the range of angles at which films can be taken to a quite narrow (typically ±10 0 ) interval and, as a general rule, the closer the angles the larger the uncertainty in the seed location reconstruction along the direction from the x-ray source to the film. (note)

  8. Locating industrial VOC sources with aircraft observations

    International Nuclear Information System (INIS)

    Toscano, P.; Gioli, B.; Dugheri, S.; Salvini, A.; Matese, A.; Bonacchi, A.; Zaldei, A.; Cupelli, V.; Miglietta, F.

    2011-01-01

    Observation and characterization of environmental pollution, focussing on Volatile Organic Compounds (VOCs), in a high-risk industrial area, are particularly important in order to provide indications on a safe level of exposure, indicate eventual priorities and advise on policy interventions. The aim of this study is to use the Solid Phase Micro Extraction (SPME) method to measure VOCs, directly coupled with atmospheric measurements taken on a small aircraft environmental platform, to evaluate and locate the presence of VOC emission sources in the Marghera industrial area. Lab analysis of collected SPME fibres and subsequent analysis of mass spectrum and chromatograms in Scan Mode allowed the detection of a wide range of VOCs. The combination of this information during the monitoring campaign allowed a model (Gaussian Plume) to be implemented that estimates the localization of emission sources on the ground. - Highlights: → Flight plan aimed at sampling industrial area at various altitudes and locations. → SPME sampling strategy was based on plume detection by means of CO 2 . → Concentrations obtained were lower than the limit values or below the detection limit. → Scan mode highlighted presence of γ-butyrolactone (GBL) compound. → Gaussian dispersion modelling was used to estimate GBL source location and strength. - An integrated strategy based on atmospheric aircraft observations and dispersion modelling was developed, aimed at estimating spatial location and strength of VOC point source emissions in industrial areas.

  9. Locating noise sources with a microphone array

    International Nuclear Information System (INIS)

    Bale, A.; Johnson, D.

    2010-01-01

    Noise pollution is one of the contributors to the public opposition of wind farms. Most of the noise produced by turbines is caused by the aerodynamic interactions between the turbine blades and the surrounding air. This poster presentation discussed a series of aeroacoustic tests conducted to account for the different in vortical structures caused by the rotation of the blades. Microphone arrays were used measure and locate the source of noise. A beam forming technique was used to measure the noise using an algorithm that identified a scanning grid on a plane where the source was thought to be located. It delayed each microphone's signal by the length of time required for the sound to travel from the scan position to each microphone, and accounted for the amplitudes according to the distance from the scan position to each microphone. Demonstration test cases were conducted using piezo buzzers attached to aluminum bars and mounted to the shaft of a DC motor that produced a rotational diameter of 0.95 meter. The buzzers were placed 1 meter from the array. Multiple sound sources at the same frequency were identified, and the moving sources were accurately measured and located. tabs., figs.

  10. Sound source location in cavitating tip vortices

    International Nuclear Information System (INIS)

    Higuchi, H.; Taghavi, R.; Arndt, R.E.A.

    1985-01-01

    Utilizing an array of three hydrophones, individual cavitation bursts in a tip vortex could be located. Theoretically, four hydrophones are necessary. Hence the data from three hydrophones are supplemented with photographic observation of the cavitating tip vortex. The cavitation sound sources are found to be localized to within one base chord length from the hydrofoil tip. This appears to correspond to the region of initial tip vortex roll-up. A more extensive study with a four sensor array is now in progress

  11. Tremor Source Location at Okmok Volcano

    Science.gov (United States)

    Reyes, C. G.; McNutt, S. R.

    2007-12-01

    Initial results using an amplitude-based tremor location program have located several active tremor episodes under Cone A, a vent within Okmok volcano's 10 km caldera. Okmok is an andesite volcano occupying the north-eastern half of Umnak Island, in the Aleutian islands. Okmok is defined by a ~2000 y.b.p. caldera that contains multiple cinder cones. Cone A, the youngest of these, extruded lava in 1997 covering the caldera floor. Since April 2003, continuous seismic data have been recorded from eight vertical short-period stations (L4-C's) installed at distances from Cone A ranging from 2 km to 31 km. In 2004 four additional 3- component broadband stations were added, co-located with continuous GPS stations. InSAR and GPS measurements of post-eruption deformation show that Okmok experienced several periods of rapid inflation (Mann and Freymueller, 2002), from the center of the 10 km diameter caldera. While there are few locatable VT earthquakes, there has been nearly continuous low-level tremor with stronger amplitude bursts occurring at variable rates and durations. The character of occurrence remained relatively constant over the course of days to weeks until the signal ceased in mid 2005. Within any day, tremor behavior remains fairly consistent, with bursts closely resembling each other, suggesting a single main process or source location. The tremor is composed of irregular waves with a broad range of frequencies, though most energy resides between ~2 Hz and 6 Hz. Attempts to locate the tremor using traditional arrival time methods fail because the signal is emergent, with envelopes too ragged to correlate on time scales that hold much hope for a location. Instead, focus was shifted to the amplitude ratios at various stations. Candidates for the tremor source include the center of inflation and Cone A, 3 km to the south-west. For all dates on record, data were band pass filtered between 1 and 5 Hz, then evaluated in 20.48 second windows (N=2048, sampling rate

  12. Methods to identify and locate spent radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The objective of this manual is to provide essential guidance to Member States with nuclear applications involving the use of a wide range of sealed radiation sources on the practical task of physically locating spent radiation sources not properly accounted for. Advice is also provided to render the located source safe on location. Refs, figs and tabs.

  13. Methods to identify and locate spent radiation sources

    International Nuclear Information System (INIS)

    1997-06-01

    The objective of this manual is to provide essential guidance to Member States with nuclear applications involving the use of a wide range of sealed radiation sources on the practical task of physically locating spent radiation sources not properly accounted for. Advice is also provided to render the located source safe on location. Refs, figs, tabs

  14. Methods to identify and locate spent radiation sources

    International Nuclear Information System (INIS)

    1995-07-01

    The objective of this manual is to provide essential guidance to Member States with nuclear applications involving the use of a wide range of sealed radiation sources on the practical task of physically locating spent radiation sources not properly accounted for. Advice is also provided to render the located source safe on location. Refs, figs and tabs

  15. Cluster analysis for determining distribution center location

    Science.gov (United States)

    Lestari Widaningrum, Dyah; Andika, Aditya; Murphiyanto, Richard Dimas Julian

    2017-12-01

    Determination of distribution facilities is highly important to survive in the high level of competition in today’s business world. Companies can operate multiple distribution centers to mitigate supply chain risk. Thus, new problems arise, namely how many and where the facilities should be provided. This study examines a fast-food restaurant brand, which located in the Greater Jakarta. This brand is included in the category of top 5 fast food restaurant chain based on retail sales. There were three stages in this study, compiling spatial data, cluster analysis, and network analysis. Cluster analysis results are used to consider the location of the additional distribution center. Network analysis results show a more efficient process referring to a shorter distance to the distribution process.

  16. Cartilage immunoprivilege depends on donor source and lesion location.

    Science.gov (United States)

    Arzi, B; DuRaine, G D; Lee, C A; Huey, D J; Borjesson, D L; Murphy, B G; Hu, J C Y; Baumgarth, N; Athanasiou, K A

    2015-09-01

    The ability to repair damaged cartilage is a major goal of musculoskeletal tissue engineering. Allogeneic (same species, different individual) or xenogeneic (different species) sources can provide an attractive source of chondrocytes for cartilage tissue engineering, since autologous (same individual) cells are scarce. Immune rejection of non-autologous hyaline articular cartilage has seldom been considered due to the popular notion of "cartilage immunoprivilege". The objective of this study was to determine the suitability of allogeneic and xenogeneic engineered neocartilage tissue for cartilage repair. To address this, scaffold-free tissue engineered articular cartilage of syngeneic (same genetic background), allogeneic, and xenogeneic origin were implanted into two different locations of the rabbit knee (n=3 per group/location). Xenogeneic engineered cartilage and control xenogeneic chondral explants provoked profound innate inflammatory and adaptive cellular responses, regardless of transplant location. Cytological quantification of immune cells showed that, while allogeneic neocartilage elicited an immune response in the patella, negligible responses were observed when implanted into the trochlea; instead the responses were comparable to microfracture-treated empty defect controls. Allogeneic neocartilage survived within the trochlea implant site and demonstrated graft integration into the underlying bone. In conclusion, the knee joint cartilage does not represent an immune privileged site, strongly rejecting xenogeneic but not allogeneic chondrocytes in a location-dependent fashion. This difference in location-dependent survival of allogeneic tissue may be associated with proximity to the synovium. Through a series of in vivo studies this research demonstrates that articular cartilage is not fully immunoprivileged. In addition, we now show that anatomical location of the defect, even within the same joint compartment, strongly influences the degree of the

  17. Sign of Radon for locate geothermic sources

    International Nuclear Information System (INIS)

    Gonzalez Teran, D.

    1991-01-01

    Evaluation of a geothermic field is based upon geological, geophysical and geochemical studies that enable the evaluation of the deposit potential, that is to say, the amount of energy per unit mass, the volume of the trapped fluid, vapor fraction and fluid chemistry. This thesis has as its objective the evaluation of radon gas emanation in high potential geothermic zones in order to utilize the results as a low cost and easy to manage complimentary tool in geothermic source prospection. In chapter I the importance and evaluation of a geothermic deposit is discussed. In chapter II the general characteristics of radon are discussed: its radioactivity and behavior upon diffusion over the earth's surface> Chapter III establishes the approach used in the geothermic field of Los Azufres, Michoacan, to carry out samplings of radon and the laboratory techniques that were used to evaluate the concentration of radon in the subsoil. Finally in chapter IV measurements of radon in the field are compared to geological faults in the area under study. The sampling zones were: low geothermic potential zone of the northern and the southern zone having a greater geothermic potential than that in the north. The study was carried out at different sampling times using plastics detectors of from 30 to 46 days from February to July. From the results obtained we concluded that the emission of radon was greater in the zones of greatest geothermic potential than in the low geothermic potential zones it was also affected by the fault structure and the time of year in which sampling was done. (Author)

  18. Enhancing source location protection in wireless sensor networks

    Science.gov (United States)

    Chen, Juan; Lin, Zhengkui; Wu, Di; Wang, Bailing

    2015-12-01

    Wireless sensor networks are widely deployed in the internet of things to monitor valuable objects. Once the object is monitored, the sensor nearest to the object which is known as the source informs the base station about the object's information periodically. It is obvious that attackers can capture the object successfully by localizing the source. Thus, many protocols have been proposed to secure the source location. However, in this paper, we examine that typical source location protection protocols generate not only near but also highly localized phantom locations. As a result, attackers can trace the source easily from these phantom locations. To address these limitations, we propose a protocol to enhance the source location protection (SLE). With phantom locations far away from the source and widely distributed, SLE improves source location anonymity significantly. Theory analysis and simulation results show that our SLE provides strong source location privacy preservation and the average safety period increases by nearly one order of magnitude compared with existing work with low communication cost.

  19. Detection, Source Location, and Analysis of Volcano Infrasound

    Science.gov (United States)

    McKee, Kathleen F.

    The study of volcano infrasound focuses on low frequency sound from volcanoes, how volcanic processes produce it, and the path it travels from the source to our receivers. In this dissertation we focus on detecting, locating, and analyzing infrasound from a number of different volcanoes using a variety of analysis techniques. These works will help inform future volcano monitoring using infrasound with respect to infrasonic source location, signal characterization, volatile flux estimation, and back-azimuth to source determination. Source location is an important component of the study of volcano infrasound and in its application to volcano monitoring. Semblance is a forward grid search technique and common source location method in infrasound studies as well as seismology. We evaluated the effectiveness of semblance in the presence of significant topographic features for explosions of Sakurajima Volcano, Japan, while taking into account temperature and wind variations. We show that topographic obstacles at Sakurajima cause a semblance source location offset of 360-420 m to the northeast of the actual source location. In addition, we found despite the consistent offset in source location semblance can still be a useful tool for determining periods of volcanic activity. Infrasonic signal characterization follows signal detection and source location in volcano monitoring in that it informs us of the type of volcanic activity detected. In large volcanic eruptions the lowermost portion of the eruption column is momentum-driven and termed the volcanic jet or gas-thrust zone. This turbulent fluid-flow perturbs the atmosphere and produces a sound similar to that of jet and rocket engines, known as jet noise. We deployed an array of infrasound sensors near an accessible, less hazardous, fumarolic jet at Aso Volcano, Japan as an analogue to large, violent volcanic eruption jets. We recorded volcanic jet noise at 57.6° from vertical, a recording angle not normally feasible

  20. Ambiguity of source location in acoustic emission technique

    International Nuclear Information System (INIS)

    Barat, P.; Mukherjee, P.; Kalyanasundaram, P.; Raj, B.

    1996-01-01

    Location of acoustic emission (AE) source in a plane is detected from the difference of the arrival times of the AE signal to at least three sensors placed on it. The detected location may not be unique in all cases. In this paper, the condition for the unambiguous solution for the location of the source has been deduced mathematically in terms of arrival times of the AE signal, the coordinate of the three sensors and the acoustic velocity. (author)

  1. Determinants of Recent Immigrants' Location Choices

    DEFF Research Database (Denmark)

    Damm, Anna Piil

    2009-01-01

    This paper exploits a Danish spatial dispersal policy on refugees which can be regarded as a natural experiment to investigate the influence of regional factors on recent immigrants' location choices. The main push factors are lack of co-nationals and immigrants. Additional push factors are lack...... of rental, including social, housing and lack of institutions for qualifying educations which explain why recent immigrants are attracted to large cities. Finally, placed refugees tend to leave locations with relatively high regional unemployment and there is indirect evidence of welfare seeking....

  2. Determinants of Recent Immigrants' Location Choices

    DEFF Research Database (Denmark)

    Damm, Anna Piil

    This paper exploits a Danish spatial dispersal policy on refugees which can be regarded a natural experiment to investigate the influence of regional factors on recent immigrants' locational choices. The main push factors are lack of co-ethnics and presence of immigrants. Additional push factors...

  3. Acoustic wavefield evolution as a function of source location perturbation

    KAUST Repository

    Alkhalifah, Tariq Ali

    2010-12-01

    The wavefield is typically simulated for seismic exploration applications through solving the wave equation for a specific seismic source location. The direct relation between the form (or shape) of the wavefield and the source location can provide insights useful for velocity estimation and interpolation. As a result, I derive partial differential equations that relate changes in the wavefield shape to perturbations in the source location, especially along the Earth\\'s surface. These partial differential equations have the same structure as the wave equation with a source function that depends on the background (original source) wavefield. The similarity in form implies that we can use familiar numerical methods to solve the perturbation equations, including finite difference and downward continuation. In fact, we can use the same Green\\'s function to solve the wave equation and its source perturbations by simply incorporating source functions derived from the background field. The solutions of the perturbation equations represent the coefficients of a Taylor\\'s series type expansion of the wavefield as a function of source location. As a result, we can speed up the wavefield calculation as we approximate the wavefield shape for sources in the vicinity of the original source. The new formula introduces changes to the background wavefield only in the presence of lateral velocity variation or in general terms velocity variations in the perturbation direction. The approach is demonstrated on the smoothed Marmousi model.

  4. Wavefield dependency on virtual shifts in the source location

    KAUST Repository

    Alkhalifah, Tariq

    2011-01-01

    shape) to lateral perturbations in the source location depends explicitly on lateral derivatives of the velocity field. For velocity models that include lateral velocity discontinuities this is problematic as such derivatives in their classical

  5. 48 CFR 319.202-2 - Locating small business sources.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Locating small business... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Policies 319.202-2 Locating small business sources. (a) OPDIVs shall foster, to the extent practicable, maximum participation by small businesses in HHS acquisitions...

  6. 48 CFR 2919.202-2 - Locating small business sources.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Locating small business... SOCIOECONOMIC PROGRAMS SMALL BUSINESS AND SMALL DISADVANTAGED BUSINESS CONCERNS Policies 2919.202-2 Locating small business sources. Any procurement conducted on an unrestricted basis will include solicitations to...

  7. 48 CFR 19.202-2 - Locating small business sources.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Locating small business... SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Policies 19.202-2 Locating small business sources. The contracting officer must, to the extent practicable, encourage maximum participation by small business...

  8. Source location of chorus emissions observed by Cluster

    Directory of Open Access Journals (Sweden)

    M. Parrot

    Full Text Available One of the objectives of the Cluster mission is to study sources of various electromagnetic waves using the four satellites. This paper describes the methods we have applied to data recorded from the STAFF spectrum analyser. This instrument provides the cross spectral matrix of three magnetic and two electric field components. This spectral matrix is analysed to determine, for each satellite, the direction of the wave normal relative to the Earth’s magnetic field as a function of frequency and of time. Due to the Cluster orbit, chorus emissions are often observed close to perigee, and the data analysis determines the direction of these waves. Three events observed during different levels of magnetic activity are reported. It is shown that the component of the Poynting vector parallel to the magnetic field changes its sense when the satellites cross the magnetic equator, which indicates that the chorus waves propagate away from the equator. Detailed analysis indicates that the source is located in close vicinity of the plane of the geomagnetic equator.

    Key words. Magnetospheric physics (plasma waves and instabilities; storms and substorms; Space plasma physics (waves and instabilities

  9. Locating the source of spreading in temporal networks

    Science.gov (United States)

    Huang, Qiangjuan; Zhao, Chengli; Zhang, Xue; Yi, Dongyun

    2017-02-01

    The topological structure of many real networks changes with time. Thus, locating the sources of a temporal network is a creative and challenging problem, as the enormous size of many real networks makes it unfeasible to observe the state of all nodes. In this paper, we propose an algorithm to solve this problem, named the backward temporal diffusion process. The proposed algorithm calculates the shortest temporal distance to locate the transmission source. We assume that the spreading process can be modeled as a simple diffusion process and by consensus dynamics. To improve the location accuracy, we also adopt four strategies to select which nodes should be observed by ranking their importance in the temporal network. Our paper proposes a highly accurate method for locating the source in temporal networks and is, to the best of our knowledge, a frontier work in this field. Moreover, our framework has important significance for controlling the transmission of diseases or rumors and formulating immediate immunization strategies.

  10. Method to Locate Contaminant Source and Estimate Emission Strength

    Directory of Open Access Journals (Sweden)

    Qu Hongquan

    2013-01-01

    Full Text Available People greatly concern the issue of air quality in some confined spaces, such as spacecraft, aircraft, and submarine. With the increase of residence time in such confined space, contaminant pollution has become a main factor which endangers life. It is urgent to identify a contaminant source rapidly so that a prompt remedial action can be taken. A procedure of source identification should be able to locate the position and to estimate the emission strength of the contaminant source. In this paper, an identification method was developed to realize these two aims. This method was developed based on a discrete concentration stochastic model. With this model, a sensitivity analysis algorithm was induced to locate the source position, and a Kalman filter was used to further estimate the contaminant emission strength. This method could track and predict the source strength dynamically. Meanwhile, it can predict the distribution of contaminant concentration. Simulation results have shown the virtues of the method.

  11. Gamma ray burst source locations with the Ulysses/Compton/PVO Network

    International Nuclear Information System (INIS)

    Cline, T.L.; Hurley, K.C.; Boer, M.; Sommer, M.; Niel, M.; Fishman, G.J.; Kouveliotou, C.; Meegan, C.A.; Paciesas, W.S.; Wilson, R.B.; Laros, J.G.; Klebesadel, R.W.

    1991-01-01

    The new interplanetary gamma-ray burst network will determine source fields with unprecedented accuracy. The baseline of the Ulysses mission and the locations of Pioneer-Venus Orbiter and of Mars Observer will ensure precision to a few tens of arc seconds. Combined with the event phenomenologies of the Burst and Transient Source Experiment on Compton Observatory, the source locations to be achieved with this network may provide a basic new understanding of the puzzle of gamma ray bursts

  12. Influence of external source location in the reactivity calculation

    International Nuclear Information System (INIS)

    Silva, Adilson Costa da; Silva, Fernando Carvalho da; Martinez, Aquilino Senra

    2011-01-01

    We used the neutron diffusion equation with external neutron sources, in cartesian geometry and the two groups of energy, to verify the influence of external neutron source locations in the reactivity calculation. For this, a coarse mesh finite difference method was developed for the adjoint flux calculation and simplifies reactivity calculation in PWR type reactor, which uses the output of the nodal expansion method. The results were obtained for different locations on the two-dimensional plane, as well as for different types of fuel elements in the reactor core. (author)

  13. Influence of external source location in the reactivity calculation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Adilson Costa da; Silva, Fernando Carvalho da; Martinez, Aquilino Senra, E-mail: asilva@con.ufrj.b, E-mail: fernando@con.ufrj.b, E-mail: Aquilino@lmp.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2011-07-01

    We used the neutron diffusion equation with external neutron sources, in cartesian geometry and the two groups of energy, to verify the influence of external neutron source locations in the reactivity calculation. For this, a coarse mesh finite difference method was developed for the adjoint flux calculation and simplifies reactivity calculation in PWR type reactor, which uses the output of the nodal expansion method. The results were obtained for different locations on the two-dimensional plane, as well as for different types of fuel elements in the reactor core. (author)

  14. Learning to locate an odour source with a mobile robot

    OpenAIRE

    Duckett, T.; Axelsson, M.; Saffiotti, A.

    2001-01-01

    We address the problem of enabling a mobile robot to locate a stationary odour source using an electronic nose constructed from gas sensors. On the hardware side, we use a stereo nose architecture consisting of two parallel chambers, each containing an identical set of sensors. On the software side, we use a recurrent artificial neural network to learn the direction to a stationary source from a time series of sensor readings. This contrasts with previous approaches, that rely on the existenc...

  15. A Comparative Study Of Source Location And Depth Estimates From ...

    African Journals Online (AJOL)

    ... the analytic signal amplitude (ASA) and the local wave number (LWN) of the total intensity magnetic field. In this study, a synthetic magnetic field due to four buried dipoles was analysed to show that estimates of source location and depth can be improved significantly by reducing the data to the pole prior to the application ...

  16. An inverse source location algorithm for radiation portal monitor applications

    International Nuclear Information System (INIS)

    Miller, Karen A.; Charlton, William S.

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  17. Location as a determinant of accommodation prices: managerial approach

    OpenAIRE

    Napierała, Tomasz; Leśniewska, Katarzyna

    2014-01-01

    In the presentation authors discuss the location-based factors’ impact on accommodation prices. The aim of the presentation is to compare the results of qualitative and quantitative research on location-based determinants of accommodation prices in Lodz Metropolitan Area (Poland). The authors employ methodological triangulation (Yeung 2000), both to explore statistical significance of location-based determinants of accommodation prices, and to present managerial opinions about the influence o...

  18. Location of an electric source facility and local area promotion

    International Nuclear Information System (INIS)

    Shimohirao, Isao

    1999-01-01

    Here were described on energy demand and supply, energy policy and local area promotion policy for basic problems important on location of electric source facilities. At present, co-existence business between electricity business and electric source location area is lacking in its activity. It seems to be necessary to enforce some systems to intend to promote it earnestly, and to effort to promote industry promotions such as introduction of some national projects, induction of electricity cost reduction for a means of business invitation, and so forth. And it is necessary to promote them under cooperations with electricity businesses, governments, universities and communities for the industrial promotion and fixation of the youth at local areas. In order to realize such necessities, further larger efforts are expected for national and local governments. (G.K.)

  19. Towards an accurate real-time locator of infrasonic sources

    Science.gov (United States)

    Pinsky, V.; Blom, P.; Polozov, A.; Marcillo, O.; Arrowsmith, S.; Hofstetter, A.

    2017-11-01

    Infrasonic signals propagate from an atmospheric source via media with stochastic and fast space-varying conditions. Hence, their travel time, the amplitude at sensor recordings and even manifestation in the so-called "shadow zones" are random. Therefore, the traditional least-squares technique for locating infrasonic sources is often not effective, and the problem for the best solution must be formulated in probabilistic terms. Recently, a series of papers has been published about Bayesian Infrasonic Source Localization (BISL) method based on the computation of the posterior probability density function (PPDF) of the source location, as a convolution of a priori probability distribution function (APDF) of the propagation model parameters with likelihood function (LF) of observations. The present study is devoted to the further development of BISL for higher accuracy and stability of the source location results and decreasing of computational load. We critically analyse previous algorithms and propose several new ones. First of all, we describe the general PPDF formulation and demonstrate that this relatively slow algorithm might be among the most accurate algorithms, provided the adequate APDF and LF are used. Then, we suggest using summation instead of integration in a general PPDF calculation for increased robustness, but this leads us to the 3D space-time optimization problem. Two different forms of APDF approximation are considered and applied for the PPDF calculation in our study. One of them is previously suggested, but not yet properly used is the so-called "celerity-range histograms" (CRHs). Another is the outcome from previous findings of linear mean travel time for the four first infrasonic phases in the overlapping consecutive distance ranges. This stochastic model is extended here to the regional distance of 1000 km, and the APDF introduced is the probabilistic form of the junction between this travel time model and range-dependent probability

  20. AE source location by neural networks with arrival time profiles

    Czech Academy of Sciences Publication Activity Database

    Chlada, Milan; Blaháček, Michal; Převorovský, Zdeněk

    2009-01-01

    Roč. 19, č. 2 (2009), s. 4-4 ISSN 1213-3825. [NDT in PROGRESS. 12.11.2009-14.11.2009, Praha] R&D Projects: GA ČR GA101/07/1518; GA ČR GA106/07/1393 Institutional research plan: CEZ:AV0Z20760514 Keywords : acoustic emission * source location * artificial neural networks Subject RIV: BI - Acoustics www.cndt.cz

  1. Locating Microseism Sources Using Spurious Arrivals in Intercontinental Noise Correlations

    Science.gov (United States)

    Retailleau, Lise; Boué, Pierre; Stehly, Laurent; Campillo, Michel

    2017-10-01

    The accuracy of Green's functions retrieved from seismic noise correlations in the microseism frequency band is limited by the uneven distribution of microseism sources at the surface of the Earth. As a result, correlation functions are often biased as compared to the expected Green's functions, and they can include spurious arrivals. These spurious arrivals are seismic arrivals that are visible on the correlation and do not belong to the theoretical impulse response. In this article, we propose to use Rayleigh wave spurious arrivals detected on correlation functions computed between European and United States seismic stations to locate microseism sources in the Atlantic Ocean. We perform a slant stack on a time distance gather of correlations obtained from an array of stations that comprises a regional deployment and a distant station. The arrival times and the apparent slowness of the spurious arrivals lead to the location of their source, which is obtained through a grid search procedure. We discuss improvements in the location through this methodology as compared to classical back projection of microseism energy. This method is interesting because it only requires an array and a distant station on each side of an ocean, conditions that can be met relatively easily.

  2. Wavefield dependency on virtual shifts in the source location

    KAUST Repository

    Alkhalifah, Tariq

    2011-02-14

    The wavefield dependence on a virtual shift in the source location can provide information helpful in velocity estimation and interpolation. However, the second-order partial differential equation (PDE) that relates changes in the wavefield form (or shape) to lateral perturbations in the source location depends explicitly on lateral derivatives of the velocity field. For velocity models that include lateral velocity discontinuities this is problematic as such derivatives in their classical definition do not exist. As a result, I derive perturbation partial differential wave equations that are independent of direct velocity derivatives and thus, provide possibilities for wavefield shape extrapolation in complex media. These PDEs have the same structure as the wave equation with a source function that depends on the background (original source) wavefield. The solutions of the perturbation equations provide the coefficients of a Taylor\\'s series type expansion for the wavefield. The new formulas introduce changes to the background wavefield only in the presence of lateral velocity variation or in general terms velocity variations in the perturbation direction. The accuracy of the representation, as demonstrated on the Marmousi model, is generally good. © 2011 European Association of Geoscientists & Engineers.

  3. Locating gamma radiation source by self collimating BGO detector system

    Energy Technology Data Exchange (ETDEWEB)

    Orion, I; Pernick, A; Ilzycer, D; Zafrir, H [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center; Shani, G [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    The need for airborne collimated gamma detector system to estimate the radiation released from a nuclear accident has been established. A BGO detector system has been developed as an array of separate seven cylindrical Bismuth Germanate scintillators, one central detector symmetrically surrounded by six detectors. In such an arrangement, each of the detectors reduced the exposure of other detectors in the array to a radiation incident from a possible specific spatial angle, around file array. This shielding property defined as `self-collimation`, differs the point source response function for each of the detectors. The BGO detector system has a high density and atomic number, and therefore provides efficient self-collimation. Using the response functions of the separate detectors enables locating point sources as well as the direction of a nuclear radioactive plume with satisfactory angular resolution, of about 10 degrees. The detector`s point source response, as function of the source direction, in a horizontal plane, has been predicted by analytical calculation, and was verified by Monte-Carlo simulation using the code EGS4. The detector`s response was tested in a laboratory-scale experiment for several gamma ray energies, and the experimental results validated the theoretical (analytical and Monte-Carlo) results. (authors).

  4. Simultaneous head tissue conductivity and EEG source location estimation.

    Science.gov (United States)

    Akalin Acar, Zeynep; Acar, Can E; Makeig, Scott

    2016-01-01

    Accurate electroencephalographic (EEG) source localization requires an electrical head model incorporating accurate geometries and conductivity values for the major head tissues. While consistent conductivity values have been reported for scalp, brain, and cerebrospinal fluid, measured brain-to-skull conductivity ratio (BSCR) estimates have varied between 8 and 80, likely reflecting both inter-subject and measurement method differences. In simulations, mis-estimation of skull conductivity can produce source localization errors as large as 3cm. Here, we describe an iterative gradient-based approach to Simultaneous tissue Conductivity And source Location Estimation (SCALE). The scalp projection maps used by SCALE are obtained from near-dipolar effective EEG sources found by adequate independent component analysis (ICA) decomposition of sufficient high-density EEG data. We applied SCALE to simulated scalp projections of 15cm(2)-scale cortical patch sources in an MR image-based electrical head model with simulated BSCR of 30. Initialized either with a BSCR of 80 or 20, SCALE estimated BSCR as 32.6. In Adaptive Mixture ICA (AMICA) decompositions of (45-min, 128-channel) EEG data from two young adults we identified sets of 13 independent components having near-dipolar scalp maps compatible with a single cortical source patch. Again initialized with either BSCR 80 or 25, SCALE gave BSCR estimates of 34 and 54 for the two subjects respectively. The ability to accurately estimate skull conductivity non-invasively from any well-recorded EEG data in combination with a stable and non-invasively acquired MR imaging-derived electrical head model could remove a critical barrier to using EEG as a sub-cm(2)-scale accurate 3-D functional cortical imaging modality. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Study of Coal Burst Source Locations in the Velenje Colliery

    Directory of Open Access Journals (Sweden)

    Goran Vižintin

    2016-06-01

    Full Text Available The Velenje coal mine (VCM is situated on the largest Slovenian coal deposit and in one of the thickest layers of coal known in the world. The thickness of the coal layer causes problems for the efficiency of extraction, since the majority of mining operations is within the coal layer. The selected longwall coal mining method with specific geometry, increasing depth of excavations, changes in stress state and naturally given geomechanical properties of rocks induce seismic events. Induced seismic events can be caused by caving processes, blasting or bursts of coal or the surrounding rock. For 2.5D visualization, data of excavations, ash content and calorific value of coal samples, hanging wall and footwall occurrence, subsidence of the surface and coal burst source locations were collected. Data and interpolation methods available in software package Surfer®12 were statistically analyzed and a Kriging (KRG interpolation method was chosen. As a result 2.5D visualizations of coal bursts source locations with geomechanical properties of coal samples taken at different depth in the coal seam in the VCM were made with data-visualization packages Surfer®12 and Voxler®3.

  6. Acoustic Emission Source Location Using a Distributed Feedback Fiber Laser Rosette

    Directory of Open Access Journals (Sweden)

    Fang Li

    2013-10-01

    Full Text Available This paper proposes an approach for acoustic emission (AE source localization in a large marble stone using distributed feedback (DFB fiber lasers. The aim of this study is to detect damage in structures such as those found in civil applications. The directional sensitivity of DFB fiber laser is investigated by calculating location coefficient using a method of digital signal analysis. In this, autocorrelation is used to extract the location coefficient from the periodic AE signal and wavelet packet energy is calculated to get the location coefficient of a burst AE source. Normalization is processed to eliminate the influence of distance and intensity of AE source. Then a new location algorithm based on the location coefficient is presented and tested to determine the location of AE source using a Delta (Δ DFB fiber laser rosette configuration. The advantage of the proposed algorithm over the traditional methods based on fiber Bragg Grating (FBG include the capability of: having higher strain resolution for AE detection and taking into account two different types of AE source for location.

  7. A location procedure for sound sources in reactor-technical enclosures

    International Nuclear Information System (INIS)

    Hamann, D.

    1982-07-01

    A passive method requiring one detector only has been developed for the location of sound emitting faults in nuclear power plant components. It is adapted for use in a frequency range the wavelength of which is of the same order of magnitude as characteristic dimensions of the considered enclosure. The location is performed in the following way: (1) For a fixed detector position the Auto Power Spectral Density (APSD) of the source to be located is measured. (2) For this detector position the APSD is calculated for the potential source locations. For this, the free-field APSD as well as the acoustic normal modes of the enclosure are necessary. (3) The measured APSD is compared with the theoretically obtained APSD's. (4) That APSD is determined which is most similar to the measured APSD, and consequently an information about the unknown source position is got. (author)

  8. Accuracy of working length determination with root ZX apex locator ...

    African Journals Online (AJOL)

    The purpose of this study was to clinically compare working length (WL) determination with root ZX apex locator and radiography, and then compare them with direct visualization method ex vivo. A total of 75 maxillary central and lateral incisors were selected. Working length determination was carried out using radiographic ...

  9. Rapidly locating sources and predicting contaminant dispersion in buildings

    International Nuclear Information System (INIS)

    Sohn, Michael D.; Reynolds, Pamela; Gadgil, Ashok J.; Sextro, Richard G.

    2002-01-01

    Contaminant releases in or near a building can lead to significant human exposures unless prompt response measures are taken. However, selecting the proper response depends in part on knowing the source locations, the amounts released, and the dispersion characteristics of the pollutants. We present an approach that estimates this information in real time. It uses Bayesian statistics to interpret measurements from sensors placed in the building yielding best estimates and uncertainties for the release conditions, including the operating state of the building. Because the method is fast, it continuously updates the estimates as measurements stream in from the sensors. We show preliminary results for characterizing a gas release in a three-floor, multi-room building at the Dugway Proving Grounds, Utah, USA

  10. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    International Nuclear Information System (INIS)

    Shukri Mohd

    2013-01-01

    Full-text: Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed Wavelet Transform analysis and Modal Location (WTML) based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) technique and DeltaTlocation. The results of the study show that the WTML method produces more accurate location results compared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure. (author)

  11. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    International Nuclear Information System (INIS)

    Mohd, Shukri; Holford, Karen M.; Pullin, Rhys

    2014-01-01

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure

  12. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Mohd, Shukri [Nondestructive Testing Group, Industrial Technology Division, Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Holford, Karen M.; Pullin, Rhys [Cardiff School of Engineering, Cardiff University, Queen' s Buildings, The Parade, CARDIFF CF24 3AA (United Kingdom)

    2014-02-12

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure.

  13. Bayesian statistics applied to the location of the source of explosions at Stromboli Volcano, Italy

    Science.gov (United States)

    Saccorotti, G.; Chouet, B.; Martini, M.; Scarpa, R.

    1998-01-01

    We present a method for determining the location and spatial extent of the source of explosions at Stromboli Volcano, Italy, based on a Bayesian inversion of the slowness vector derived from frequency-slowness analyses of array data. The method searches for source locations that minimize the error between the expected and observed slowness vectors. For a given set of model parameters, the conditional probability density function of slowness vectors is approximated by a Gaussian distribution of expected errors. The method is tested with synthetics using a five-layer velocity model derived for the north flank of Stromboli and a smoothed velocity model derived from a power-law approximation of the layered structure. Application to data from Stromboli allows for a detailed examination of uncertainties in source location due to experimental errors and incomplete knowledge of the Earth model. Although the solutions are not constrained in the radial direction, excellent resolution is achieved in both transverse and depth directions. Under the assumption that the horizontal extent of the source does not exceed the crater dimension, the 90% confidence region in the estimate of the explosive source location corresponds to a small volume extending from a depth of about 100 m to a maximum depth of about 300 m beneath the active vents, with a maximum likelihood source region located in the 120- to 180-m-depth interval.

  14. Error Analysis of Determining Airplane Location by Global Positioning System

    OpenAIRE

    Hajiyev, Chingiz; Burat, Alper

    1999-01-01

    This paper studies the error analysis of determining airplane location by global positioning system (GPS) using statistical testing method. The Newton Rhapson method positions the airplane at the intersection point of four spheres. Absolute errors, relative errors and standard deviation have been calculated The results show that the positioning error of the airplane varies with the coordinates of GPS satellite and the airplane.

  15. Direct determination of the hit locations from experimental HPGe pulses

    Energy Technology Data Exchange (ETDEWEB)

    Désesquelles, P., E-mail: Pierre.Desesquelles@in2p3.fr [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dimmock, M.R. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Ljungvall, J. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nelson, L. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nga, D.-T. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nolan, P.J.; Rigby, S.V. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Van-Oanh, N.-T. [Univ. Paris-Sud, LCP UMR8000 CNRS, 15 rue G. Clémenceau, 91405 Orsay (France)

    2013-11-21

    The gamma-tracking technique optimises the determination of the energy and emission angle of gamma-rays detected by modern segmented HPGe detectors. This entails the determination, using the delivered pulse shapes, of the interaction points of the gamma-ray within the crystal. The direct method presented here allows the localisation of the hits using only a large sample of pulses detected in the actual operating conditions. No external crystal scanning system or pulse shape simulation code is needed. In order to validate this method, it is applied to sets of pulses obtained using the University of Liverpool scanning system. The hit locations are determined by the method with good precision.

  16. Preferred practice location at medical school commencement strongly determines graduates' rural preferences and work locations.

    Science.gov (United States)

    Herd, Marie S; Bulsara, Max K; Jones, Michael P; Mak, Donna B

    2017-02-01

    To identify factors influencing whether Australian medical graduates prefer to, or actually, work rurally. Secondary analysis of longitudinal data from Medical Schools Outcomes Database (MSOD) using univariate and multivariate logistic regression. Twenty Australian medical schools. Australian or New Zealand citizens and Australian permanent residents who completed MSOD questionnaires between 2006 and 2013. Preferred and actual work locations 1 (PGY1) and 3 (PGY3) years postgraduation. Of 20 784 participants, 4028 completed a PGY1 or PGY3 questionnaire. Self-reported preference for rural practice location at medical school commencement was the most consistent independent predictor of whether a graduate would have a rural location preference at PGY1 (odds ratio (OR) 6.07, 95% confidence interval (CI) 4.91-7.51) and PGY3 (OR 7.95, 95% CI 4.93-12.84), and work rurally during PGY1 (OR 1.38, 95% CI 1.01-1.88) and PGY3 (OR 1.86, 95% CI 1.30-2.64). The effect of preferred practice location at medical school commencement is independent of, and enhances the effect of, rural background. Graduates of graduate-entry programs or with dependent children were less likely to have worked rurally during PGY1 and PGY3 respectively. The most consistent factor associated with rural preferences and work location was students' preferred location of practice at medical school commencement; this association is independent of, and enhances the effect of, rural background. Better understanding of what determines rural preference at medical school commencement and its influence on rural workplace outcomes beyond PGY3 is required to inform Australian medical school selection policies and rural health curricula. © 2016 National Rural Health Alliance Inc.

  17. Location and Position Determination Algorithm For Humanoid Soccer Robot

    Directory of Open Access Journals (Sweden)

    Oei Kurniawan Utomo

    2016-03-01

    Full Text Available The algorithm of location and position determination was designed for humanoid soccer robot. The robots have to be able to control the ball effectively on the field of Indonesian Robot Soccer Competition which has a size of 900 cm x 600 cm. The algorithm of location and position determination uses parameters, such as the goalpost’s thickness, the compass value, and the robot’s head servo value. The goalpost’s thickness is detected using The Centre of Gravity method. The width of the goalpost detected is analyzed using the principles of camera geometry to determine the distance between the robot and the goalpost. The tangent value of head servo’s tilt angle is used to determine the distance between the robot and the ball. The distance between robot-goalpost and the distance between robot-ball are processed with the difference of head servo’s pan angle and compass value using trigonometric formulas to determine the coordinates of the robot and the ball in the Cartesian coordinates.

  18. Acoustic wavefield evolution as a function of source location perturbation

    KAUST Repository

    Alkhalifah, Tariq Ali

    2010-01-01

    differential equations have the same structure as the wave equation with a source function that depends on the background (original source) wavefield. The similarity in form implies that we can use familiar numerical methods to solve the perturbation equations

  19. Locating Supplemental Sources of Revenue to Finance Universities in Nigeria.

    Science.gov (United States)

    Ogunla, Akin L.

    1989-01-01

    Identifies possible sources of supplemental income to finance Nigerian universities, including households and commercial and industrial firms. A consumption tax imposed on certain goods and services would generate needed funds. Also, because firms employ university graduates to earn higher profits, their turnover income should be taxed to support…

  20. METHOD FOR DETERMINATION OF FOCAL PLANE LOCATION OF FOCUSING COMPONENTS

    Directory of Open Access Journals (Sweden)

    A. I. Ivashko

    2017-01-01

    Full Text Available Mass-production of different laser systems often requires utilization of the focal spot size method for determination of output laser beam spatial characteristics. The main challenge of this method is high accuracy maintenance of a CCD camera beam profiler in the collecting lens focal plane. The aim of our work is development of new method for placing of photodetector array in the collecting lens focal plane with high accuracy.Proposed technique is based on focusing of several parallel laser beams. Determination of the focal plane position requires only longitudinal translation of the CCD-camera to find a point of laser beams intersection. Continuous-wave (CW diode-pumped laser emitting in the spectral region near 1μm was created to satisfy the requirements of the developed technique. Designed microchip laser generates two stigmatic Gaussian beams with automatically parallel beam axes due to independent pumping of different areas of the one microchip crystal having the same cavity mirrors.It was theoretically demonstrated that developed method provides possibility of the lenses focal plane determination with 1 % accuracy. The microchip laser generates two parallel Gaussian beams with divergence of about 10 mrad. Laser output power can be varied in the range of 0.1–1.5 W by changing the pumping laser diode electrical current. The distance between two beam axes can be changed in the range of 0.5–5.0 mm.We have proposed method for determination of positive lens focal plane location by using of CCDcamera and two laser beams with parallel axes without utilization of additional optical devices. We have developed CW longitudinally diode pumped microchip laser emitting in the 1-μm spectral region that can be used in the measuring instrument that doesn’t require precision mechanical components for determination of focal plane location with 1 % accuracy. The overall dimensions of laser head was 70 × 40 × 40 mm3 and maximum power consumption was

  1. Determination of foveal location using scanning laser polarimetry.

    Science.gov (United States)

    VanNasdale, Dean A; Elsner, Ann E; Weber, Anke; Miura, Masahiro; Haggerty, Bryan P

    2009-03-25

    The fovea is the retinal location responsible for our most acute vision. There are several methods used to localize the fovea, but the fovea is not always easily identifiable. Landmarks used to determine the foveal location are variable in normal subjects and localization becomes even more difficult in instances of retinal disease. In normal subjects, the photoreceptor axons that make up the Henle fiber layer are cylindrical and the radial orientation of these fibers is centered on the fovea. The Henle fiber layer exhibits form birefringence, which predictably changes polarized light in scanning laser polarimetry imaging. In this study 3 graders were able to repeatably identify the fovea in 35 normal subjects using near infrared image types with differing polarization content. There was little intra-grader, inter-grader, and inter-image variability in the graded foveal position for 5 of the 6 image types examined, with accuracy sufficient for clinical purposes. This study demonstrates that scanning laser polarimetry imaging can localize the fovea by using structural properties inherent in the central macula.

  2. Locating sources within a dense sensor array using graph clustering

    Science.gov (United States)

    Gerstoft, P.; Riahi, N.

    2017-12-01

    We develop a model-free technique to identify weak sources within dense sensor arrays using graph clustering. No knowledge about the propagation medium is needed except that signal strengths decay to insignificant levels within a scale that is shorter than the aperture. We then reinterpret the spatial coherence matrix of a wave field as a matrix whose support is a connectivity matrix of a graph with sensors as vertices. In a dense network, well-separated sources induce clusters in this graph. The geographic spread of these clusters can serve to localize the sources. The support of the covariance matrix is estimated from limited-time data using a hypothesis test with a robust phase-only coherence test statistic combined with a physical distance criterion. The latter criterion ensures graph sparsity and thus prevents clusters from forming by chance. We verify the approach and quantify its reliability on a simulated dataset. The method is then applied to data from a dense 5200 element geophone array that blanketed of the city of Long Beach (CA). The analysis exposes a helicopter traversing the array and oil production facilities.

  3. Analytic-numerical method of determining the freezing front location

    Directory of Open Access Journals (Sweden)

    R. Grzymkowski

    2011-07-01

    Full Text Available Mathematical modeling of thermal processes combined with the reversible phase transitions of type: solid phase – liquid phase leads to formulation of the parabolic boundary problems with the moving boundary. Solution of such defined problem requires, most often, to use sophisticated numerical techniques and far advanced mathematical tools. Excellent illustration of the complexity of considered problems, as well as of the variety of approaches used for finding their solutions, gives the papers [1-4]. In the current paper, the authors present the, especially attractive from the engineer point of view, analytic-numerical method for finding the approximate solution of selected class of problems which can be reduced to the one-phase solidification problem of a plate with the unknown a priori, varying in time boundary of the region in which the solution is sought. Proposed method is based on the known formalism of initial expansion of the sought function describing the temperature field into the power series, some coefficients of which are determined with the aid of boundary conditions, and on the approximation of the function defining the location of freezing front with the broken line, parameters of which are numerically determined.

  4. Accuracy of working length determination with root ZX apex locator ...

    African Journals Online (AJOL)

    Jane

    2011-07-18

    Jul 18, 2011 ... generation of electronic apex locators (EALs), called root. ZX (J. Morita Co., Tustin, .... dentinocemento junction. Dent Items Interest, 50: 855-857. ... apex locator with an automatic compensation circuit. J. Endod. 28: 706-709.

  5. Determining potential locations for biomass valorization using a macro screening approach

    Energy Technology Data Exchange (ETDEWEB)

    Van Dael, M.; Van Passel, S.; Schreurs, E. [Research Group of Environmental Economics, Centre for Environmental Sciences, Hasselt University, Agoralaan Gebouw D, 3590 Diepenbeek (Belgium); Pelkmans, L.; Guisson, R. [VITO, Boeretang 200, 2400 Mol (Belgium); Swinnen, G. [Research Group of Marketing, Hasselt University, Agoralaan Gebouw D, 3590 Diepenbeek (Belgium)

    2012-10-15

    European policy states that by 2020 at least 20% of final energy consumption should come from renewable energy sources. Biomass as a renewable energy source cannot be disregarded in order to attain this target. In this study a macro screening approach is developed to determine potential locations for biomass valorization in a specified region. The approach consists of five steps: (1) criteria determination, (2) data gathering, (3) weight assignment, (4) final score, (5) spatial representation. The resulting outcome provides a first well balanced scan of the possibilities for energy production using regional biomass. This way policy makers and investors can be supported and motivated to study the possibilities of building energy production plants at specific locations in more detail, which can be described as a 'micro-screening'. In our case study the approach is applied to determine the potentially interesting locations to establish a biomass project. The region has been limited to the forty-four communities in the province of Limburg (Belgium). The macro screening approach has shown to be very effective since the amount of interesting locations has been reduced drastically.

  6. Comparison of various current electronic apex locators to determine ...

    African Journals Online (AJOL)

    2014-10-16

    Oct 16, 2014 ... measurements of the WL, especially in cases of infected necrotic pulps and chronic apical periodontitis, led to significantly lower ..... root canal length: A preliminary report using the Tri Auto ZX apex‑locating handpiece.

  7. Determinants of Dispensing Location in the TRICARE Senior Pharmacy Program

    Science.gov (United States)

    2005-01-01

    proximity to an MTF on TSRx use and on uti - lization of the different dispensing locations; and the impact of MTF formulary restrictions on use of the...Conclusions and Policy Implications Our analysis of the TSRx program, which focused on describing uti - lization patterns by dispensing location and on...manufacturers do. In the public sector, some Medicaid programs have recently hired physicians and pharmacists to visit doctors’ offices and encourage them to

  8. Transport of perfluoroalkyl substances (PFAS) from an arctic glacier to downstream locations: implications for sources.

    Science.gov (United States)

    Kwok, Karen Y; Yamazaki, Eriko; Yamashita, Nobuyoshi; Taniyasu, Sachi; Murphy, Margaret B; Horii, Yuichi; Petrick, Gert; Kallerborn, Roland; Kannan, Kurunthachalam; Murano, Kentaro; Lam, Paul K S

    2013-03-01

    Perfluoroalkyl substances (PFAS) have been globally detected in various environmental matrices, yet their fate and transport to the Arctic is still unclear, especially for the European Arctic. In this study, concentrations of 17 PFAS were quantified in two ice cores (n=26), surface snow (n=9) and surface water samples (n=14) collected along a spatial gradient in Svalbard, Norway. Concentrations of selected ions (Na(+), SO4(2-), etc.) were also determined for tracing the origins and sources of PFAS. Perfluorobutanoate (PFBA), perfluorooctanoate (PFOA) and perfluorononanoate (PFNA) were the dominant compounds found in ice core samples. Taking PFOA, PFNA and perfluorooctane-sulfonate (PFOS) as examples, higher concentrations were detected in the middle layers of the ice cores representing the period of 1997-2000. Lower concentrations of C8-C12 perfluorocarboxylates (PFCAs) were detected in comparison with concentrations measured previously in an ice core from the Canadian Arctic, indicating that contamination levels in the European Arctic are lower. Average PFAS concentrations were found to be lower in surface snow and melted glacier water samples, while increased concentrations were observed in river water downstream near the coastal area. Perfluorohexanesulfonate (PFHxS) was detected in the downstream locations, but not in the glacier, suggesting existence of local sources of this compound. Long-range atmospheric transport of PFAS was the major deposition pathway for the glaciers, while local sources (e.g., skiing activities) were identified in the downstream locations. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Locating the source of diffusion in complex networks by time-reversal backward spreading

    Science.gov (United States)

    Shen, Zhesi; Cao, Shinan; Wang, Wen-Xu; Di, Zengru; Stanley, H. Eugene

    2016-03-01

    Locating the source that triggers a dynamical process is a fundamental but challenging problem in complex networks, ranging from epidemic spreading in society and on the Internet to cancer metastasis in the human body. An accurate localization of the source is inherently limited by our ability to simultaneously access the information of all nodes in a large-scale complex network. This thus raises two critical questions: how do we locate the source from incomplete information and can we achieve full localization of sources at any possible location from a given set of observable nodes. Here we develop a time-reversal backward spreading algorithm to locate the source of a diffusion-like process efficiently and propose a general locatability condition. We test the algorithm by employing epidemic spreading and consensus dynamics as typical dynamical processes and apply it to the H1N1 pandemic in China. We find that the sources can be precisely located in arbitrary networks insofar as the locatability condition is assured. Our tools greatly improve our ability to locate the source of diffusion in complex networks based on limited accessibility of nodal information. Moreover, they have implications for controlling a variety of dynamical processes taking place on complex networks, such as inhibiting epidemics, slowing the spread of rumors, pollution control, and environmental protection.

  10. Comparison of various current electronic apex locators to determine ...

    African Journals Online (AJOL)

    Objective: The objective was to compare in vitro the accuracy of three electronic apex locators (EALs) (DentaPort ZX [Morita Co., Tokyo, Japan], SIROEndo Pocket [Sirona Dental Systems, ... All teeth were embedded in an alginate model, and the electronic measurements were taken following the manufacturers' orientations.

  11. 44 CFR 9.7 - Determination of proposed action's location.

    Science.gov (United States)

    2010-10-01

    ... rise of floodwater; (iii) Duration of flooding; (iv) Available warning and evacuation time and routes... Regional Offices/Natural and Technological Hazards Division Department of the Interior: Geological Survey... with the U.S. Fish and Wildlife Service (FWS) for information concerning the location, scale and type...

  12. Impact source location on composite CNG storage tank using acoustic emission energy based signal mapping method

    Energy Technology Data Exchange (ETDEWEB)

    Han, Byeong Hee; Yoon, Dong Jin; Park, Chun Soo [Korea Research Institute of Standards and Science, Center for Safety Measurement, Daejeon (Korea, Republic of); Lee, Young Shin [Dept. of Mechanical Design Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2016-10-15

    Acoustic emission (AE) is one of the most powerful techniques for detecting damages and identify damage location during operations. However, in case of the source location technique, there is some limitation in conventional AE technology, because it strongly depends on wave speed in the corresponding structures having heterogeneous composite materials. A compressed natural gas(CNG) pressure vessel is usually made of carbon fiber composite outside of vessel for the purpose of strengthening. In this type of composite material, locating impact damage sources exactly using conventional time arrival method is difficult. To overcome this limitation, this study applied the previously developed Contour D/B map technique to four types of CNG storage tanks to identify the source location of damages caused by external shock. The results of the identification of the source location for different types were compared.

  13. An eikonal-based formulation for traveltime perturbation with respect to the source location

    KAUST Repository

    Alkhalifah, Tariq

    2010-11-01

    Traveltime calculations amount to solving the nonlinear eikonal equation for a given source location. The relationship between the eikonal solution and its perturbations is analyzed with respect to the source location and a partial differential equation is developed that relates the traveltime field for one source location to that for a nearby source. This linear first-order equation in one form depends on lateral changes in velocity and in another form is independent of the velocity field and relies on second-order derivatives of the original traveltime field. For stable finite-difference calculations, this requires the velocity field to be smooth in a sense similar to ray-tracing requirements. Our formulation for traveltime perturbation has several potential applications, such that as traveltime calculation by source-location perturbation, velocity-independent interpolation including datuming, and velocity estimation. Additionally, higher-order expansions provide parameters necessary for Gaussian-beam computations. © 2010 Society of Exploration Geophysicists.

  14. An eikonal-based formulation for traveltime perturbation with respect to the source location

    KAUST Repository

    Alkhalifah, Tariq; Fomel, Sergey

    2010-01-01

    Traveltime calculations amount to solving the nonlinear eikonal equation for a given source location. The relationship between the eikonal solution and its perturbations is analyzed with respect to the source location and a partial differential equation is developed that relates the traveltime field for one source location to that for a nearby source. This linear first-order equation in one form depends on lateral changes in velocity and in another form is independent of the velocity field and relies on second-order derivatives of the original traveltime field. For stable finite-difference calculations, this requires the velocity field to be smooth in a sense similar to ray-tracing requirements. Our formulation for traveltime perturbation has several potential applications, such that as traveltime calculation by source-location perturbation, velocity-independent interpolation including datuming, and velocity estimation. Additionally, higher-order expansions provide parameters necessary for Gaussian-beam computations. © 2010 Society of Exploration Geophysicists.

  15. Determining the spatial variability of personal sampler inlet locations.

    Science.gov (United States)

    Vinson, Robert; Volkwein, Jon; McWilliams, Linda

    2007-09-01

    This article examines the spatial variability of dust concentrations within a coal miner's breathing zone and the impact of sampling location at the cap lamp, nose, and lapel. Tests were conducted in the National Institute for Safety and Health Pittsburgh Research Laboratory full-scale, continuous miner gallery using three prototype personal dust monitors (PDM). The dust masses detected by the PDMs were used to calculate the percentage difference of dust mass between the cap lamp and the nose and between the lapel and the nose. The calculated percentage differences of the masses ranged from plus 12% to minus 25%. Breathing zone tests were also conducted in four underground coal mines using the torso of a mannequin to simulate a miner. Coal mine dust was sampled with multi-cyclone sampling cans mounted directly in front of the mannequin near the cap lamp, nose, and lapel. These four coal mine tests found that the spatial variability of dust levels and imprecision of the current personal sampler is a greater influence than the sampler location within the breathing zone. However, a one-sample t-test of this data did find that the overall mean value of the cap lamp/nose ratio was not significantly different than 1 (p-value = 0.21). However, when applied to the overall mean value of the lapel/nose ratio there was a significant difference from 1 (p-value sampling location for coal mine dust samples. But these results suggest that the cap location is slightly more indicative of what is breathed through the nose area.

  16. A New Wave Equation Based Source Location Method with Full-waveform Inversion

    KAUST Repository

    Wu, Zedong

    2017-05-26

    Locating the source of a passively recorded seismic event is still a challenging problem, especially when the velocity is unknown. Many imaging approaches to focus the image do not address the velocity issue and result in images plagued with illumination artifacts. We develop a waveform inversion approach with an additional penalty term in the objective function to reward the focusing of the source image. This penalty term is relaxed early to allow for data fitting, and avoid cycle skipping, using an extended source. At the later stages the focusing of the image dominates the inversion allowing for high resolution source and velocity inversion. We also compute the source location explicitly and numerical tests show that we obtain good estimates of the source locations with this approach.

  17. The effect of location of a convective heat source on displacement ventilation: CFD study

    Energy Technology Data Exchange (ETDEWEB)

    Park, H.J.; Holland, D. [Dunham Associates, Inc., Minneapolis, MN (United States). Advanced Technologies Group

    2001-08-01

    Two-dimensional computational simulations are performed to examine the effect of vertical location of a convective heat source on thermal displacement ventilation systems. In this study, a heat source is modeled with seven different heights from the floor (0.5, 0.75, 1.0, 1.25, 1.5, 1.75, 2.0 m) in a displacement ventilation environment. The flow and temperature fields in thermal displacement ventilation systems vary depending on the location of the heat source. As the heat source rises, the convective heat gain from the heat source to an occupied zone becomes less significant. This effect changes the temperature field and results in the reduction of the cooling load in the occupied zone. The stratification level is also affected by the heat source location at a given flow rate. (author)

  18. High-resolution and super stacking of time-reversal mirrors in locating seismic sources

    KAUST Repository

    Cao, Weiping; Hanafy, Sherif M.; Schuster, Gerard T.; Zhan, Ge; Boonyasiriwat, Chaiwoot

    2011-01-01

    Time reversal mirrors can be used to backpropagate and refocus incident wavefields to their actual source location, with the subsequent benefits of imaging with high-resolution and super-stacking properties. These benefits of time reversal mirrors

  19. Estimation of microwave source location in precipitating electron fluxes according to Viking satellite data

    International Nuclear Information System (INIS)

    Khrushchinskij, A.A.; Ostapenko, A.A.; Gustafsson, G.; Eliasson, L.; Sandal, I.

    1989-01-01

    According to the Viking satellite data on electron fluxes in the 0.1-300 keV energy range, the microburst source location is estimated. On the basis of experimental delays in detected peaks in different energy channels and theoretical calculations of these delays within the dipole field model (L∼ 4-5.5), it is shown that the most probable source location is the equatorial region with the centre, 5-10 0 shifted towards the ionosphere

  20. Determining supply chain safety stock level and location

    Directory of Open Access Journals (Sweden)

    Bahareh Amirjabbari

    2014-01-01

    Full Text Available Purpose: The lean methodology and its principles have widely been applied in supply chain management in recent decades. Manufacturers are one of the most important contributors in a supply chain and inventory plays a paramount role for them to become lean. Therefore, there should be appropriate management of inventory and all of its drivers in accordance with a lean strategy. Safety stock is one of the main drivers of inventory; it protects against increasing the stretch in the breaking points of the supply chain, which in turn can result in possible reduction of inventory. In this paper an optimization model and a simulation model are developed and applied in a real case to optimize the safety stock level with the objective of logistics cost minimization.Design/methodology/approach: In order to optimize the safety stock level while minimizing logistics costs, a nonlinear cost minimization safety stock model is developed in this paper and then it is applied in a real world manufacturing case company. A safety stock simulation model based on appropriate metrics in the case company’s supply chain performance is also provided.Findings: These models result in not only the optimum levels but also locations of safety stock within the supply chain.Originality/value: In this research, two models of cost minimization and simulation have been developed and also applied in a real case company to result in not only optimized levels but also optimized locations of safety stock across the whole supply chain. In addition, the appropriate supply chain performance measurement metrics have been introduced in this paper and the simulation model is developed based on those.

  1. Determination of geostatistically representative sampling locations in Porsuk Dam Reservoir (Turkey)

    Science.gov (United States)

    Aksoy, A.; Yenilmez, F.; Duzgun, S.

    2013-12-01

    Several factors such as wind action, bathymetry and shape of a lake/reservoir, inflows, outflows, point and diffuse pollution sources result in spatial and temporal variations in water quality of lakes and reservoirs. The guides by the United Nations Environment Programme and the World Health Organization to design and implement water quality monitoring programs suggest that even a single monitoring station near the center or at the deepest part of a lake will be sufficient to observe long-term trends if there is good horizontal mixing. In stratified water bodies, several samples can be required. According to the guide of sampling and analysis under the Turkish Water Pollution Control Regulation, a minimum of five sampling locations should be employed to characterize the water quality in a reservoir or a lake. The European Union Water Framework Directive (2000/60/EC) states to select a sufficient number of monitoring sites to assess the magnitude and impact of point and diffuse sources and hydromorphological pressures in designing a monitoring program. Although existing regulations and guidelines include frameworks for the determination of sampling locations in surface waters, most of them do not specify a procedure in establishment of monitoring aims with representative sampling locations in lakes and reservoirs. In this study, geostatistical tools are used to determine the representative sampling locations in the Porsuk Dam Reservoir (PDR). Kernel density estimation and kriging were used in combination to select the representative sampling locations. Dissolved oxygen and specific conductivity were measured at 81 points. Sixteen of them were used for validation. In selection of the representative sampling locations, care was given to keep similar spatial structure in distributions of measured parameters. A procedure was proposed for that purpose. Results indicated that spatial structure was lost under 30 sampling points. This was as a result of varying water

  2. Using Weighted Graphs for Computationally Efficient WLAN Location Determination

    DEFF Research Database (Denmark)

    Thomsen, Bent; Hansen, Rene

    2007-01-01

    use of existing WLAN infrastructures. The technique consists of building a radio map of signal strength measurements which is searched to determine a position estimate. While the fingerprinting technique has produced good positioning accuracy results, the technique incurs a substantial computational...

  3. An efficient closed-form solution for acoustic emission source location in three-dimensional structures

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2014-02-01

    Full Text Available This paper presents an efficient closed-form solution (ECS for acoustic emission(AE source location in three-dimensional structures using time difference of arrival (TDOA measurements from N receivers, N ≥ 6. The nonlinear location equations of TDOA are simplified to linear equations. The unique analytical solution of AE sources for unknown velocity system is obtained by solving the linear equations. The proposed ECS method successfully solved the problems of location errors resulting from measured deviations of velocity as well as the existence and multiplicity of solutions induced by calculations of square roots in existed close-form methods.

  4. A Practical Method of Acoustic Emission Source Location in Anisotropic Composite Laminates

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Kon; Kang, Yong Kyu; Kwon, Oh Yang [Inha University, Incheon (Korea, Republic of)

    2003-06-15

    Since the velocity is dependent on the fiber orientation in anisotropic composites, the application of traditional acoustic emission (AE) source location techniques based on the constant velocity to composite structures has been practically impossible. The anisotropy makes the source location procedure complicated and deteriorates the accuracy of the location. In this study, we have divided the region of interest(ROI) into a set of finite elements, taken each element as a virtual source, and calculated the arrival time differences between sensors by using the velocities at every degree from 0 to 90. The calculated and the experimentally measured values of the arrival time difference aye then compared to minimize the location error. The results from two different materials, namely AA6061-T6 and CFRP(uni-directional; UD, [0]{sub 32}4 ) laminate confirmed the practical usefulness of the proposed method

  5. Planar location of the simulative acoustic source based on fiber optic sensor array

    Science.gov (United States)

    Liang, Yi-Jun; Liu, Jun-feng; Zhang, Qiao-ping; Mu, Lin-lin

    2010-06-01

    A fiber optic sensor array which is structured by four Sagnac fiber optic sensors is proposed to detect and locate a simulative source of acoustic emission (AE). The sensing loops of Sagnac interferometer (SI) are regarded as point sensors as their small size. Based on the derived output light intensity expression of SI, the optimum work condition of the Sagnac fiber optic sensor is discussed through the simulation of MATLAB. Four sensors are respectively placed on a steel plate to structure the sensor array and the location algorithms are expatiated. When an impact is generated by an artificial AE source at any position of the plate, the AE signal will be detected by four sensors at different times. With the help of a single chip microcomputer (SCM) which can calculate the position of the AE source and display it on LED, we have implemented an intelligent detection and location.

  6. Bayesian inverse modeling and source location of an unintended 131I release in Europe in the fall of 2011

    Science.gov (United States)

    Tichý, Ondřej; Šmídl, Václav; Hofman, Radek; Šindelářová, Kateřina; Hýža, Miroslav; Stohl, Andreas

    2017-10-01

    In the fall of 2011, iodine-131 (131I) was detected at several radionuclide monitoring stations in central Europe. After investigation, the International Atomic Energy Agency (IAEA) was informed by Hungarian authorities that 131I was released from the Institute of Isotopes Ltd. in Budapest, Hungary. It was reported that a total activity of 342 GBq of 131I was emitted between 8 September and 16 November 2011. In this study, we use the ambient concentration measurements of 131I to determine the location of the release as well as its magnitude and temporal variation. As the location of the release and an estimate of the source strength became eventually known, this accident represents a realistic test case for inversion models. For our source reconstruction, we use no prior knowledge. Instead, we estimate the source location and emission variation using only the available 131I measurements. Subsequently, we use the partial information about the source term available from the Hungarian authorities for validation of our results. For the source determination, we first perform backward runs of atmospheric transport models and obtain source-receptor sensitivity (SRS) matrices for each grid cell of our study domain. We use two dispersion models, FLEXPART and Hysplit, driven with meteorological analysis data from the global forecast system (GFS) and from European Centre for Medium-range Weather Forecasts (ECMWF) weather forecast models. Second, we use a recently developed inverse method, least-squares with adaptive prior covariance (LS-APC), to determine the 131I emissions and their temporal variation from the measurements and computed SRS matrices. For each grid cell of our simulation domain, we evaluate the probability that the release was generated in that cell using Bayesian model selection. The model selection procedure also provides information about the most suitable dispersion model for the source term reconstruction. Third, we select the most probable location of

  7. Bayesian inverse modeling and source location of an unintended 131I release in Europe in the fall of 2011

    Directory of Open Access Journals (Sweden)

    O. Tichý

    2017-10-01

    Full Text Available In the fall of 2011, iodine-131 (131I was detected at several radionuclide monitoring stations in central Europe. After investigation, the International Atomic Energy Agency (IAEA was informed by Hungarian authorities that 131I was released from the Institute of Isotopes Ltd. in Budapest, Hungary. It was reported that a total activity of 342 GBq of 131I was emitted between 8 September and 16 November 2011. In this study, we use the ambient concentration measurements of 131I to determine the location of the release as well as its magnitude and temporal variation. As the location of the release and an estimate of the source strength became eventually known, this accident represents a realistic test case for inversion models. For our source reconstruction, we use no prior knowledge. Instead, we estimate the source location and emission variation using only the available 131I measurements. Subsequently, we use the partial information about the source term available from the Hungarian authorities for validation of our results. For the source determination, we first perform backward runs of atmospheric transport models and obtain source-receptor sensitivity (SRS matrices for each grid cell of our study domain. We use two dispersion models, FLEXPART and Hysplit, driven with meteorological analysis data from the global forecast system (GFS and from European Centre for Medium-range Weather Forecasts (ECMWF weather forecast models. Second, we use a recently developed inverse method, least-squares with adaptive prior covariance (LS-APC, to determine the 131I emissions and their temporal variation from the measurements and computed SRS matrices. For each grid cell of our simulation domain, we evaluate the probability that the release was generated in that cell using Bayesian model selection. The model selection procedure also provides information about the most suitable dispersion model for the source term reconstruction. Third, we select the most

  8. Locating the Source of Atmospheric Contamination Based on Data From the Kori Field Tracer Experiment

    Directory of Open Access Journals (Sweden)

    Piotr Kopka

    2015-01-01

    Full Text Available Accidental releases of hazardous material into the atmosphere pose high risks to human health and the environment. Thus it would be valuable to develop an emergency reaction system which can recognize the probable location of the source based only on concentrations of the released substance as reported by a network of sensors. We apply a methodology combining Bayesian inference with Sequential Monte Carlo (SMC methods to the problem of locating the source of an atmospheric contaminant. The input data for this algorithm are the concentrations of a given substance gathered continuously in time. We employ this algorithm to locating a contamination source using data from a field tracer experiment covering the Kori nuclear site and conducted in May 2001. We use the second-order Closure Integrated PUFF Model (SCIPUFF of atmospheric dispersion as the forward model to predict concentrations at the sensors' locations. We demonstrate that the source of continuous contamination may be successfully located even in the very complicated, hilly terrain surrounding the Kori nuclear site. (original abstract

  9. Accurate source location from waves scattered by surface topography: Applications to the Nevada and North Korean test sites

    Science.gov (United States)

    Shen, Y.; Wang, N.; Bao, X.; Flinders, A. F.

    2016-12-01

    Scattered waves generated near the source contains energy converted from the near-field waves to the far-field propagating waves, which can be used to achieve location accuracy beyond the diffraction limit. In this work, we apply a novel full-wave location method that combines a grid-search algorithm with the 3D Green's tensor database to locate the Non-Proliferation Experiment (NPE) at the Nevada test site and the North Korean nuclear tests. We use the first arrivals (Pn/Pg) and their immediate codas, which are likely dominated by waves scattered at the surface topography near the source, to determine the source location. We investigate seismograms in the frequency of [1.0 2.0] Hz to reduce noises in the data and highlight topography scattered waves. High resolution topographic models constructed from 10 and 90 m grids are used for Nevada and North Korea, respectively. The reference velocity model is based on CRUST 1.0. We use the collocated-grid finite difference method on curvilinear grids to calculate the strain Green's tensor and obtain synthetic waveforms using source-receiver reciprocity. The `best' solution is found based on the least-square misfit between the observed and synthetic waveforms. To suppress random noises, an optimal weighting method for three-component seismograms is applied in misfit calculation. Our results show that the scattered waves are crucial in improving resolution and allow us to obtain accurate solutions with a small number of stations. Since the scattered waves depends on topography, which is known at the wavelengths of regional seismic waves, our approach yields absolute, instead of relative, source locations. We compare our solutions with those of USGS and other studies. Moreover, we use differential waveforms to locate pairs of the North Korea tests from years 2006, 2009, 2013 and 2016 to further reduce the effects of unmodeled heterogeneities and errors in the reference velocity model.

  10. An FBG acoustic emission source locating system based on PHAT and GA

    Science.gov (United States)

    Shen, Jing-shi; Zeng, Xiao-dong; Li, Wei; Jiang, Ming-shun

    2017-09-01

    Using the acoustic emission locating technology to monitor the health of the structure is important for ensuring the continuous and healthy operation of the complex engineering structures and large mechanical equipment. In this paper, four fiber Bragg grating (FBG) sensors are used to establish the sensor array to locate the acoustic emission source. Firstly, the nonlinear locating equations are established based on the principle of acoustic emission, and the solution of these equations is transformed into an optimization problem. Secondly, time difference extraction algorithm based on the phase transform (PHAT) weighted generalized cross correlation provides the necessary conditions for the accurate localization. Finally, the genetic algorithm (GA) is used to solve the optimization model. In this paper, twenty points are tested in the marble plate surface, and the results show that the absolute locating error is within the range of 10 mm, which proves the accuracy of this locating method.

  11. Methods to identify and locate spent radiation sources; Metodos para la identificacion y localizacion de fuentes radiactivas gastadas

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The objective of this manual is to provide essential guidance to Member States with nuclear applications involving the use of a wide range of sealed radiation sources on the practical task of physically locating spent radiation sources not properly accounted for. Advice is also provided to render the located source safe on location. Refs, figs, tabs.

  12. An automated multi-scale network-based scheme for detection and location of seismic sources

    Science.gov (United States)

    Poiata, N.; Aden-Antoniow, F.; Satriano, C.; Bernard, P.; Vilotte, J. P.; Obara, K.

    2017-12-01

    We present a recently developed method - BackTrackBB (Poiata et al. 2016) - allowing to image energy radiation from different seismic sources (e.g., earthquakes, LFEs, tremors) in different tectonic environments using continuous seismic records. The method exploits multi-scale frequency-selective coherence in the wave field, recorded by regional seismic networks or local arrays. The detection and location scheme is based on space-time reconstruction of the seismic sources through an imaging function built from the sum of station-pair time-delay likelihood functions, projected onto theoretical 3D time-delay grids. This imaging function is interpreted as the location likelihood of the seismic source. A signal pre-processing step constructs a multi-band statistical representation of the non stationary signal, i.e. time series, by means of higher-order statistics or energy envelope characteristic functions. Such signal-processing is designed to detect in time signal transients - of different scales and a priori unknown predominant frequency - potentially associated with a variety of sources (e.g., earthquakes, LFE, tremors), and to improve the performance and the robustness of the detection-and-location location step. The initial detection-location, based on a single phase analysis with the P- or S-phase only, can then be improved recursively in a station selection scheme. This scheme - exploiting the 3-component records - makes use of P- and S-phase characteristic functions, extracted after a polarization analysis of the event waveforms, and combines the single phase imaging functions with the S-P differential imaging functions. The performance of the method is demonstrated here in different tectonic environments: (1) analysis of the one year long precursory phase of 2014 Iquique earthquake in Chile; (2) detection and location of tectonic tremor sources and low-frequency earthquakes during the multiple episodes of tectonic tremor activity in southwestern Japan.

  13. Site Characterization of the Source Physics Experiment Phase II Location Using Seismic Reflection Data

    Science.gov (United States)

    Sexton, E. A.; Snelson, C. M.; Chipman, V.; Emer, D. F.; White, R. L.; Emmitt, R.; Wright, A. A.; Drellack, S.; Huckins-Gang, H.; Mercadante, J.; Floyd, M.; McGowin, C.; Cothrun, C.; Bonal, N.

    2013-12-01

    An objective of the Source Physics Experiment (SPE) is to identify low-yield nuclear explosions from a regional distance. Low-yield nuclear explosions can often be difficult to discriminate among the clutter of natural and man-made explosive events (e.g., earthquakes and mine blasts). The SPE is broken into three phases. Phase I has provided the first of the physics-based data to test the empirical models that have been used to discriminate nuclear events. The Phase I series of tests were placed within a highly fractured granite body. The evolution of the project has led to development of Phase II, to be placed within the opposite end member of geology, an alluvium environment, thereby increasing the database of waveforms to build upon in the discrimination models. Both the granite and alluvium sites have hosted nearby nuclear tests, which provide comparisons for the chemical test data. Phase III of the SPE is yet to be determined. For Phase II of the experiment, characterization of the location is required to develop the geologic/geophysical models for the execution of the experiment. Criteria for the location are alluvium thickness of approximately 170 m and a water table below 170 m; minimal fracturing would be ideal. A P-wave mini-vibroseis survey was conducted at a potential site in alluvium to map out the subsurface geology. The seismic reflection profile consisted of 168 geophone stations, spaced 5 m apart. The mini-vibe was a 7,000-lb peak-force source, starting 57.5 m off the north end of the profile and ending 57.5 m past the southern-most geophone. The length of the profile was 835 m. The source points were placed every 5 m, equally spaced between geophones to reduce clipping. The vibroseis sweep was from 20 Hz down to 180 Hz over 8 seconds, and four sweeps were stacked at each shot location. The shot gathers show high signal-to-noise ratios with clear first arrivals across the entire spread and the suggestion of some shallow reflectors. The data were

  14. Locating a compact odor source using a four-channel insect electroantennogram sensor

    Energy Technology Data Exchange (ETDEWEB)

    Myrick, A J; Baker, T C [Chemical Ecology Laboratory, Department of Entomology, Pennsylvania State University, University Park, PA 16802 (United States)

    2011-03-15

    Here we demonstrate the feasibility of using an array of live insects to detect concentrated packets of odor and infer the location of an odor source ({approx}15 m away) using a backward Lagrangian dispersion model based on the Langevin equation. Bayesian inference allows uncertainty to be quantified, which is useful for robotic planning. The electroantennogram (EAG) is the biopotential developed between the tissue at the tip of an insect antenna and its base, which is due to the massed response of the olfactory receptor neurons to an odor stimulus. The EAG signal can carry tens of bits per second of information with a rise time as short as 12 ms (K A Justice 2005 J. Neurophiol. 93 2233-9). Here, instrumentation including a GPS with a digital compass and an ultrasonic 2D anemometer has been integrated with an EAG odor detection scheme, allowing the location of an odor source to be estimated by collecting data at several downwind locations. Bayesian inference in conjunction with a Lagrangian dispersion model, taking into account detection errors, has been implemented resulting in an estimate of the odor source location within 0.2 m of the actual location.

  15. Locating a compact odor source using a four-channel insect electroantennogram sensor

    International Nuclear Information System (INIS)

    Myrick, A J; Baker, T C

    2011-01-01

    Here we demonstrate the feasibility of using an array of live insects to detect concentrated packets of odor and infer the location of an odor source (∼15 m away) using a backward Lagrangian dispersion model based on the Langevin equation. Bayesian inference allows uncertainty to be quantified, which is useful for robotic planning. The electroantennogram (EAG) is the biopotential developed between the tissue at the tip of an insect antenna and its base, which is due to the massed response of the olfactory receptor neurons to an odor stimulus. The EAG signal can carry tens of bits per second of information with a rise time as short as 12 ms (K A Justice 2005 J. Neurophiol. 93 2233-9). Here, instrumentation including a GPS with a digital compass and an ultrasonic 2D anemometer has been integrated with an EAG odor detection scheme, allowing the location of an odor source to be estimated by collecting data at several downwind locations. Bayesian inference in conjunction with a Lagrangian dispersion model, taking into account detection errors, has been implemented resulting in an estimate of the odor source location within 0.2 m of the actual location.

  16. A hybrid algorithm for stochastic single-source capacitated facility location problem with service level requirements

    Directory of Open Access Journals (Sweden)

    Hosseinali Salemi

    2016-04-01

    Full Text Available Facility location models are observed in many diverse areas such as communication networks, transportation, and distribution systems planning. They play significant role in supply chain and operations management and are one of the main well-known topics in strategic agenda of contemporary manufacturing and service companies accompanied by long-lasting effects. We define a new approach for solving stochastic single source capacitated facility location problem (SSSCFLP. Customers with stochastic demand are assigned to set of capacitated facilities that are selected to serve them. It is demonstrated that problem can be transformed to deterministic Single Source Capacitated Facility Location Problem (SSCFLP for Poisson demand distribution. A hybrid algorithm which combines Lagrangian heuristic with adjusted mixture of Ant colony and Genetic optimization is proposed to find lower and upper bounds for this problem. Computational results of various instances with distinct properties indicate that proposed solving approach is efficient.

  17. The Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael; Rots, Arnold; Primini, Francis A.; Evans, Ian N.; Glotfelty, Kenny J.; Hain, Roger; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Danny G. Gibbs, II; Grier, John D.; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.; Zografou, Panagoula

    2009-09-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory are used to generate one of the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  18. Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael L.; Rots, A. H.; Primini, F. A.; Evans, I. N.; Glotfelty, K. J.; Hain, R.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory will used to generate the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  19. Chemometric Analysis for Pollution Source Assessment of Harbour Sediments in Arctic Locations

    DEFF Research Database (Denmark)

    Pedersen, Kristine B.; Lejon, Tore; Jensen, Pernille Erland

    2015-01-01

    Pollution levels, pollutant distribution and potential source assessments based on multivariate analysis (chemometrics) were made for harbour sediments from two Arctic locations; Hammerfest in Norway and Sisimiut in Greenland. High levels of heavy metals were detected in addition to organic...... pollutants. Preliminary assessments based on principal component analysis (PCA) revealed different sources and pollutant distribution in the sediments of the two harbours. Tributyltin (TBT) was, however, found to originate from point source(s), and the highest concentrations of TBT in both harbours were...... indicated relation primarily to German, Russian and American mixtures in Hammerfest; and American, Russian and Japanese mixtures in Sisimiut. PCA was shown to be an important tool for identifying pollutant sources and differences in pollutant composition in relation to sediment characteristics....

  20. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  1. Characteristics of Love and Rayleigh waves in ambient noise: wavetype ratio, source location and seasonal behavior

    Science.gov (United States)

    Juretzek, C.; Perleth, M.; Hadziioannou, C.

    2015-12-01

    Ambient seismic noise has become an important source of signal for tomography and monitoring purposes. Better understanding of the noise field characteristics is crucial to further improve noise applications. Our knowledge about the common and different origins of Love and Rayleigh waves in the microseism bands is still limited. This applies in particular to constraints on source locations and source mechanisms of Love waves. Here, 3-component beamforming is used to distinguish between the differently polarized wave types present in the noise field recorded at several arrays across Europe. The focus lies on frequencies around the primary and secondary microseismic bands. We compare characteristics of Love and Rayleigh wave noise, such as source directions and frequency content. Further, Love to Rayleigh wave ratios are measured at each array, and a dependence on direction is observed. We constrain the corresponding source regions of both wave types by backprojection. By using a full year of data in 2013, we are able to track the seasonal changes in our observations of Love-to-Rayleigh ratio and source locations.

  2. Locating single-point sources from arrival times containing large picking errors (LPEs): the virtual field optimization method (VFOM)

    Science.gov (United States)

    Li, Xi-Bing; Wang, Ze-Wei; Dong, Long-Jun

    2016-01-01

    Microseismic monitoring systems using local location techniques tend to be timely, automatic and stable. One basic requirement of these systems is the automatic picking of arrival times. However, arrival times generated by automated techniques always contain large picking errors (LPEs), which may make the location solution unreliable and cause the integrated system to be unstable. To overcome the LPE issue, we propose the virtual field optimization method (VFOM) for locating single-point sources. In contrast to existing approaches, the VFOM optimizes a continuous and virtually established objective function to search the space for the common intersection of the hyperboloids, which is determined by sensor pairs other than the least residual between the model-calculated and measured arrivals. The results of numerical examples and in-site blasts show that the VFOM can obtain more precise and stable solutions than traditional methods when the input data contain LPEs. Furthermore, we discuss the impact of LPEs on objective functions to determine the LPE-tolerant mechanism, velocity sensitivity and stopping criteria of the VFOM. The proposed method is also capable of locating acoustic sources using passive techniques such as passive sonar detection and acoustic emission.

  3. Source apportionment and location by selective wind sampling and Positive Matrix Factorization.

    Science.gov (United States)

    Venturini, Elisa; Vassura, Ivano; Raffo, Simona; Ferroni, Laura; Bernardi, Elena; Passarini, Fabrizio

    2014-10-01

    In order to determine the pollution sources in a suburban area and identify the main direction of their origin, PM2.5 was collected with samplers coupled with a wind select sensor and then subjected to Positive Matrix Factorization (PMF) analysis. In each sample, soluble ions, organic carbon, elemental carbon, levoglucosan, metals, and Polycyclic Aromatic Hydrocarbons (PAHs) were determined. PMF results identified six main sources affecting the area: natural gas home appliances, motor vehicles, regional transport, biomass combustion, manufacturing activities, and secondary aerosol. The connection of factor temporal trends with other parameters (i.e., temperature, PM2.5 concentration, and photochemical processes) confirms factor attributions. PMF analysis indicated that the main source of PM2.5 in the area is secondary aerosol. This should be mainly due to regional contributions, owing to both the secondary nature of the source itself and the higher concentration registered in inland air masses. The motor vehicle emission source contribution is also important. This source likely has a prevalent local origin. The most toxic determined components, i.e., PAHs, Cd, Pb, and Ni, are mainly due to vehicular traffic. Even if this is not the main source in the study area, it is the one of greatest concern. The application of PMF analysis to PM2.5 collected with this new sampling technique made it possible to obtain more detailed results on the sources affecting the area compared to a classical PMF analysis.

  4. Identification of sources of aerosol particles in three locations in eastern Botswana

    Science.gov (United States)

    Chimidza, S.; Moloi, K.

    2000-07-01

    Airborne particles have been collected using a dichotomous virtual impactor at three different locations in the eastern part of Botswana: Serowe, Selibe-Phikwe, and Francistown. The particles were separated into two fractions (fine and coarse). Sampling at the three locations was done consecutively during the months of July and August, which are usually dry and stable. The sampling time for each sample was 12 hours during the day. For elemental composition, energy-dispersive x-ray fluorescence technique was used. Correlations and principal component analysis with varimax rotation were used to identify major sources of aerosol particles. In all the three places, soil was found to be the main source of aerosol particles. A copper-nickel mine and smelter at Selibe-Phikwe was found to be not only a source of copper and nickel particles in Selibe-Phikwe but also a source of these particles in far places like Serowe. In Selibe-Phikwe and Francistown, car exhaust was found to be the major source of fine particles of lead and bromine.

  5. The use of permit markets for incorporating source location. The case of acid rain in Europe

    International Nuclear Information System (INIS)

    Steiner, U.; Tinggaard Svendsen, G.

    1997-01-01

    The paper shows that cost-effective involvement of the source location involves utmost difficulty in practice. Based on the RAINS model, it is recommended that source location should be ignored in a European market for SO 2 , as is the case in the US Acid Rain Program. The RAINS-model predicts a cost-saving of 37 percent but an average loss of 2 percent in ecological protection. To overcome this reduction in protection, we recommend that some of the large cost-savings should be reallocated in further overall reduction and that the countries suffering the most from introducing the permit-market should be compensated by receiving extra permits in the initial distribution. (au)

  6. Acoustic emission non-destructive testing of structures using source location techniques.

    Energy Technology Data Exchange (ETDEWEB)

    Beattie, Alan G.

    2013-09-01

    The technology of acoustic emission (AE) testing has been advanced and used at Sandia for the past 40 years. AE has been used on structures including pressure vessels, fire bottles, wind turbines, gas wells, nuclear weapons, and solar collectors. This monograph begins with background topics in acoustics and instrumentation and then focuses on current acoustic emission technology. It covers the overall design and system setups for a test, with a wind turbine blade as the object. Test analysis is discussed with an emphasis on source location. Three test examples are presented, two on experimental wind turbine blades and one on aircraft fire extinguisher bottles. Finally, the code for a FORTRAN source location program is given as an example of a working analysis program. Throughout the document, the stress is on actual testing of real structures, not on laboratory experiments.

  7. Precise tremor source locations and amplitude variations along the lower-crustal central San Andreas Fault

    Science.gov (United States)

    Shelly, David R.; Hardebeck, Jeanne L.

    2010-01-01

    We precisely locate 88 tremor families along the central San Andreas Fault using a 3D velocity model and numerous P and S wave arrival times estimated from seismogram stacks of up to 400 events per tremor family. Maximum tremor amplitudes vary along the fault by at least a factor of 7, with by far the strongest sources along a 25 km section of the fault southeast of Parkfield. We also identify many weaker tremor families, which have largely escaped prior detection. Together, these sources extend 150 km along the fault, beneath creeping, transitional, and locked sections of the upper crustal fault. Depths are mostly between 18 and 28 km, in the lower crust. Epicenters are concentrated within 3 km of the surface trace, implying a nearly vertical fault. A prominent gap in detectible activity is located directly beneath the region of maximum slip in the 2004 magnitude 6.0 Parkfield earthquake.

  8. Coded aperture detector for high precision gamma-ray burst source locations

    International Nuclear Information System (INIS)

    Helmken, H.; Gorenstein, P.

    1977-01-01

    Coded aperture collimators in conjunction with position-sensitive detectors are very useful in the study of transient phenomenon because they combine broad field of view, high sensitivity, and an ability for precise source locations. Since the preceeding conference, a series of computer simulations of various detector designs have been carried out with the aid of a CDC 6400. Particular emphasis was placed on the development of a unit consisting of a one-dimensional random or periodic collimator in conjunction with a two-dimensional position-sensitive Xenon proportional counter. A configuration involving four of these units has been incorporated into the preliminary design study of the Transient Explorer (ATREX) satellite and are applicable to any SAS or HEAO type satellite mission. Results of this study, including detector response, fields of view, and source location precision, will be presented

  9. Determining the Location of DNA Modification and Mutation Caused by UVB Light in Skin Cancer

    Science.gov (United States)

    2013-09-01

    reads were then processed to determine the dinucleotide composition on the 5’ end by separating the Watson and Crick strands, and the dinucleotide...AD_________________ Award Number: W81XWH-12-1-0333 TITLE: Determining the Location of DNA ...COVERED 15 August 2012 – 14 August 2013 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Determining the Location of DNA Modification and Mutation Caused

  10. Travel-time source-specific station correction improves location accuracy

    Science.gov (United States)

    Giuntini, Alessandra; Materni, Valerio; Chiappini, Stefano; Carluccio, Roberto; Console, Rodolfo; Chiappini, Massimo

    2013-04-01

    Accurate earthquake locations are crucial for investigating seismogenic processes, as well as for applications like verifying compliance to the Comprehensive Test Ban Treaty (CTBT). Earthquake location accuracy is related to the degree of knowledge about the 3-D structure of seismic wave velocity in the Earth. It is well known that modeling errors of calculated travel times may have the effect of shifting the computed epicenters far from the real locations by a distance even larger than the size of the statistical error ellipses, regardless of the accuracy in picking seismic phase arrivals. The consequences of large mislocations of seismic events in the context of the CTBT verification is particularly critical in order to trigger a possible On Site Inspection (OSI). In fact, the Treaty establishes that an OSI area cannot be larger than 1000 km2, and its larger linear dimension cannot be larger than 50 km. Moreover, depth accuracy is crucial for the application of the depth event screening criterion. In the present study, we develop a method of source-specific travel times corrections based on a set of well located events recorded by dense national seismic networks in seismically active regions. The applications concern seismic sequences recorded in Japan, Iran and Italy. We show that mislocations of the order of 10-20 km affecting the epicenters, as well as larger mislocations in hypocentral depths, calculated from a global seismic network and using the standard IASPEI91 travel times can be effectively removed by applying source-specific station corrections.

  11. High-resolution and super stacking of time-reversal mirrors in locating seismic sources

    KAUST Repository

    Cao, Weiping

    2011-07-08

    Time reversal mirrors can be used to backpropagate and refocus incident wavefields to their actual source location, with the subsequent benefits of imaging with high-resolution and super-stacking properties. These benefits of time reversal mirrors have been previously verified with computer simulations and laboratory experiments but not with exploration-scale seismic data. We now demonstrate the high-resolution and the super-stacking properties in locating seismic sources with field seismic data that include multiple scattering. Tests on both synthetic data and field data show that a time reversal mirror has the potential to exceed the Rayleigh resolution limit by factors of 4 or more. Results also show that a time reversal mirror has a significant resilience to strong Gaussian noise and that accurate imaging of source locations from passive seismic data can be accomplished with traces having signal-to-noise ratios as low as 0.001. Synthetic tests also demonstrate that time reversal mirrors can sometimes enhance the signal by a factor proportional to the square root of the product of the number of traces, denoted as N and the number of events in the traces. This enhancement property is denoted as super-stacking and greatly exceeds the classical signal-to-noise enhancement factor of. High-resolution and super-stacking are properties also enjoyed by seismic interferometry and reverse-time migration with the exact velocity model. © 2011 European Association of Geoscientists & Engineers.

  12. Measurement of acoustic characteristics of Japanese Buddhist temples in relation to sound source location and direction.

    Science.gov (United States)

    Soeta, Yoshiharu; Shimokura, Ryota; Kim, Yong Hee; Ohsawa, Tomohiro; Ito, Ken

    2013-05-01

    Although temples are important buildings in the Buddhist community, the acoustic quality has not been examined in detail. Buddhist monks change the location and direction according to the ceremony, and associated acoustical changes have not yet been examined scientifically. To discuss the desired acoustics of temples, it is necessary to know the acoustic characteristics appropriate for each phase of a ceremony. In this study, acoustic measurements were taken at various source locations and directions in Japanese temples. A directional loudspeaker was used as the source to provide vocal acoustic fields, and impulse responses were measured and analyzed. The speech transmission index was higher and the interaural cross-correlation coefficient was lower for the sound source directed toward the side wall than that directed toward the altar. This suggests that the change in direction improves speech intelligibility, and the asymmetric property of direct sound and complex reflections from the altar and side wall increases the apparent source width. The large and coupled-like structure of the altar of a Buddhist temple may have reinforced the reverberation components and the table in the altar, which is called the "syumidan," may have decreased binaural coherence.

  13. 77 FR 48549 - Eastman Kodak Company, IPS-Dayton Location, Dayton, OH; Notice of Affirmative Determination...

    Science.gov (United States)

    2012-08-14

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-81,387] Eastman Kodak Company, IPS--Dayton Location, Dayton, OH; Notice of Affirmative Determination Regarding Application for...) applicable to workers and former workers of Eastman Kodak Company, IPS- Dayton Location, Dayton, Ohio...

  14. Source contribution of PM₂.₅ at different locations on the Malaysian Peninsula.

    Science.gov (United States)

    Ee-Ling, Ooi; Mustaffa, Nur Ili Hamizah; Amil, Norhaniza; Khan, Md Firoz; Latif, Mohd Talib

    2015-04-01

    This study determined the source contribution of PM2.5 (particulate matter heavy metals. Principal component analysis with multilinear regressions were used to identify the possible sources of PM2.5. The range of PM2.5 was between 10 ± 3 and 30 ± 7 µg m(-3). Sulfate (SO4 (2-)) was the major ionic compound detected and zinc was found to dominate the heavy metals. Source apportionment analysis revealed that motor vehicle and soil dust dominated the composition of PM2.5 in the urban area. Domestic waste combustion dominated in the suburban area, while biomass burning dominated in the rural area.

  15. information source accessibility and usage as determinants

    African Journals Online (AJOL)

    UDS-CAPTURED

    1990-04-28

    Apr 28, 1990 ... accessibility and business performance of the community banks over a six-year period. The ... relationship with the banks' business performance. ..... Marketing Management ... Effects of the Information on the Business Performance of Banks. ..... 'Information sources used for strategic planning decisions.

  16. Determining the Location of DNA Modification and Mutation Caused by UVB Light in Skin Cancer

    Science.gov (United States)

    2015-09-01

    Award Number: W81XWH-12-1-0333 TITLE: Determining the Location of DNA Modification and Mutation Caused by UVB Light in Skin Cancer PRINCIPAL...COVERED 15 Aug 2012 – 14 Aug 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER W81XWH-12-1-0333 Determining the Location of DNA Modification and Mutation ...sequencing libraries generated for both yeast and human cells show pyrimidine bias on the 5’ end, indicating that we are sequencing the dimers

  17. Determining the VLF/ULF source height using phase measurements

    Science.gov (United States)

    Ryabov, A.; Kotik, D. S.

    2012-12-01

    Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.

  18. Tracking the MSL-SAM methane detection source location Through Mars Regional Atmospheric Modeling System (MRAMS)

    Science.gov (United States)

    Pla-García, Jorge

    2016-04-01

    1. Introduction: The putative in situ detection of methane by Sample Analysis at Mars (SAM) instrument suite on Curiosi-ty at Gale crater has garnered significant attention because of the potential implications for the presence of geological methane sources or indigenous Martian organisms [1, 2]. SAM reported detection of back-ground levels of atmospheric methane of mean value 0.69±0.25 parts per billion by volume (ppbv) at the 95% confidence interval (CI). Additionally, in four sequential measurements spanning a 60-sol period, SAM observed elevated levels of methane of 7.2±2.1 ppbv (95% CI), implying that Mars is episodically producing methane from an additional unknown source. There are many major unresolved questions regard-ing this detection: 1) What are the potential sources of the methane release? 2) What causes the rapid decrease in concentration? and 3) Where is the re-lease location? 4) How spatially extensive is the re-lease? 5) For how long is CH4 released? Regarding the first question, the source of methane, is so far not identified. It could be related with geo-logical process like methane release from clathrates [3], serpentinisation [4] and volcanism [5]; or due to biological activity from methanogenesis [6]. To answer the second question, the rapid decrease in concentration, it is important to note that the photo-chemical lifetime of methane is of order 100 years, much longer than the atmospheric mixing time scale, and thus the gas should tend to be well mixed except near a source or shortly after an episodic release. The observed spike of 7 ppb from the background of System (MRAMS). The model was focused on rover locations using nested grids with a spacing of 330 meters on the in-nermost grid that is centered over the landing [8, 9]. MRAMS is ideally suited for this investigation; the model is explicitly designed to simulate Mars' at-mospheric circulations at the mesoscale and smaller with realistic, high-resolution surface properties [10, 11

  19. An acoustic vector based approach to locate low frequency noise sources in 3D

    NARCIS (Netherlands)

    Bree, H.-E. de; Ostendorf, C.; Basten, T.

    2009-01-01

    Although low frequency noise is an issue of huge societal importance, traditional acoustic testing methods have limitations in finding the low frequency source. It is hard to determine the direction of the noise using traditional microphones. Three dimensional sound probes capturing the particle

  20. Comparison of digital radiography and apex locator with the conventional method in root length determination of primary teeth

    Directory of Open Access Journals (Sweden)

    I E Neena

    2011-01-01

    Full Text Available Aim: The purpose of this study was to compare the Working length in primary teeth endodontics using intra oral digital radiovisiography and apex locator with conventional method for accuracy. Materials and Methods: This in vivo study was conducted on 30 primary teeth which were indicated for pulpectomy in the patients of the age group of 5-11 years All experimental teeth had adequate remaining tooth structure for rubber dam isolation and radiographicaly visible canals. Endodontic treatment was required due to irreversible pulpitis or pulp necrosis. A standardized intraoral periapical radiograph of the tooth was taken using conventional method by paralleling technique. The distance between the source and the tooth, tooth and the films were standardized using X-ray positioning device. During the pulpectomy procedure, the working length was determined by digital radiograph and apex locator. The measurements were then compared with the conventional method of root canal measurement technique for accuracy Result: From the results obtained we can conclude that Working length determined in primary molars using digital radiography and Apex locator did not show any significant difference in the mean working length measurements when compared with the conventional radiographic method. Conclusions: Apex locator is comparable to conventional radiograph in determining the working length without radiation in the primary teeth. Intraoral digital radiography is the safest method in determining the working length with significant reduction in radiation exposure.Hence, both the techniques can be safely used as alternatives to conventional radiographic methods in determining working length in primary teeth.

  1. Joint Source Location and Focal Mechanism Inversion: efficiency, accuracy and applications

    Science.gov (United States)

    Liang, C.; Yu, Y.

    2017-12-01

    The analysis of induced seismicity has become a common practice to evaluate the results of hydraulic fracturing treatment. Liang et al (2016) proposed a joint Source Scanning Algorithms (jSSA for short) to obtain microseismic events and focal mechanisms simultaneously. The jSSA is superior over traditional SSA in many aspects, but the computation cost is too significant to be applied in real time monitoring. In this study, we have developed several scanning schemas to reduce computation time. A multi-stage scanning schema is proved to be able to improve the efficiency significantly while also retain its accuracy. A series of tests have been carried out by using both real field data and synthetic data to evaluate the accuracy of the method and its dependence on noise level, source depths, focal mechanisms and other factors. The surface-based arrays have better constraints on horizontal location errors (0.5). For sources with varying rakes, dips, strikes and depths, the errors are mostly controlled by the partition of positive and negative polarities in different quadrants. More evenly partitioned polarities in different quadrants yield better results in both locations and focal mechanisms. Nevertheless, even with bad resolutions for some FMs, the optimized jSSA method can still improve location accuracies significantly. Based on much more densely distributed events and focal mechanisms, a gridded stress inversion is conducted to get a evenly distributed stress field. The full potential of the jSSA has yet to be explored in different directions, especially in earthquake seismology as seismic array becoming incleasingly dense.

  2. Summit Petroleum Corporation Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  3. Single Source Determination for General Dynamics

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  4. Neural network AE source location apart from structure size and material

    Czech Academy of Sciences Publication Activity Database

    Chlada, Milan; Převorovský, Zdeněk; Blaháček, Michal

    2010-01-01

    Roč. 28, - (2010), s. 99-107 ISSN 0730-0050. [European Conference on Acoustic Emission Testing 2010 /29./. Vídeň, 08.09.2010-10.09.2010] R&D Projects: GA ČR(CZ) GAP104/10/1430; GA MPO(CZ) FR-TI1/274 Institutional research plan: CEZ:AV0Z20760514 Keywords : AE source location * artificial neural network * arrival time profiles Subject RIV: BI - Acoustics http://www.ndt.net/search/abstract.php3?AbsID=10828

  5. An improved cut-and-solve algorithm for the single-source capacitated facility location problem

    DEFF Research Database (Denmark)

    Gadegaard, Sune Lauth; Klose, Andreas; Nielsen, Lars Relund

    2018-01-01

    In this paper, we present an improved cut-and-solve algorithm for the single-source capacitated facility location problem. The algorithm consists of three phases. The first phase strengthens the integer program by a cutting plane algorithm to obtain a tight lower bound. The second phase uses a two......-level local branching heuristic to find an upper bound, and if optimality has not yet been established, the third phase uses the cut-and-solve framework to close the optimality gap. Extensive computational results are reported, showing that the proposed algorithm runs 10–80 times faster on average compared...

  6. Locating and Quantifying Broadband Fan Sources Using In-Duct Microphones

    Science.gov (United States)

    Dougherty, Robert P.; Walker, Bruce E.; Sutliff, Daniel L.

    2010-01-01

    In-duct beamforming techniques have been developed for locating broadband noise sources on a low-speed fan and quantifying the acoustic power in the inlet and aft fan ducts. The NASA Glenn Research Center's Advanced Noise Control Fan was used as a test bed. Several of the blades were modified to provide a broadband source to evaluate the efficacy of the in-duct beamforming technique. Phased arrays consisting of rings and line arrays of microphones were employed. For the imaging, the data were mathematically resampled in the frame of reference of the rotating fan. For both the imaging and power measurement steps, array steering vectors were computed using annular duct modal expansions, selected subsets of the cross spectral matrix elements were used, and the DAMAS and CLEAN-SC deconvolution algorithms were applied.

  7. Affective attitudes to face images associated with intracerebral EEG source location before face viewing.

    Science.gov (United States)

    Pizzagalli, D; Koenig, T; Regard, M; Lehmann, D

    1999-01-01

    We investigated whether different, personality-related affective attitudes are associated with different brain electric field (EEG) sources before any emotional challenge (stimulus exposure). A 27-channel EEG was recorded in 15 subjects during eyes-closed resting. After recording, subjects rated 32 images of human faces for affective appeal. The subjects in the first (i.e., most negative) and fourth (i.e., most positive) quartile of general affective attitude were further analyzed. The EEG data (mean=25+/-4. 8 s/subject) were subjected to frequency-domain model dipole source analysis (FFT-Dipole-Approximation), resulting in 3-dimensional intracerebral source locations and strengths for the delta-theta, alpha, and beta EEG frequency band, and for the full range (1.5-30 Hz) band. Subjects with negative attitude (compared to those with positive attitude) showed the following source locations: more inferior for all frequency bands, more anterior for the delta-theta band, more posterior and more right for the alpha, beta and 1.5-30 Hz bands. One year later, the subjects were asked to rate the face images again. The rating scores for the same face images were highly correlated for all subjects, and original and retest affective mean attitude was highly correlated across subjects. The present results show that subjects with different affective attitudes to face images had different active, cerebral, neural populations in a task-free condition prior to viewing the images. We conclude that the brain functional state which implements affective attitude towards face images as a personality feature exists without elicitors, as a continuously present, dynamic feature of brain functioning. Copyright 1999 Elsevier Science B.V.

  8. Energy based source location by using acoustic emission for damage detection in steel and composite CNG tank

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Sik; Han, Byeong Hee; Park, Choon Su; Yoon, Dong Jin [Center for Safety Measurements, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2015-10-15

    Acoustic emission (AE) is an effective nondestructive test that uses transient elastic wave generated by the rapid release of energy within a material to detect any further growth or expansion of existing defects. Over the past decades, because of environmental issues, the use of compressed natural gas (CNG) as an alternative fuel for vehicles is increasing because of environmental issues. For this reason, the importance and necessity of detecting defects on a CNG fuel tank has also come to the fore. The conventional AE method used for source location is highly affected by the wave speed on the structure, and this creates problems in inspecting a composite CNG fuel tank. Because the speed and dispersion characteristics of the wave are different according to direction of structure and laminated layers. In this study, both the conventional AE method and the energy based contour map method were used for source location. This new method based on pre-acquired D/B was used for overcoming the limitation of damage localization in a composite CNG fuel tank specimen which consists of a steel liner cylinder overwrapped by GFRP. From the experimental results, it is observed that the damage localization is determined with a small error at all tested points by using the energy based contour map method, while there were a number of mis-locations or large errors at many tested points by using the conventional AE method. Therefore, the energy based contour map method used in this work is more suitable technology for inspecting composite structures.

  9. Reconstruction of source location in a network of gravitational wave interferometric detectors

    International Nuclear Information System (INIS)

    Cavalier, Fabien; Barsuglia, Matteo; Bizouard, Marie-Anne; Brisson, Violette; Clapson, Andre-Claude; Davier, Michel; Hello, Patrice; Kreckelbergh, Stephane; Leroy, Nicolas; Varvella, Monica

    2006-01-01

    This paper deals with the reconstruction of the direction of a gravitational wave source using the detection made by a network of interferometric detectors, mainly the LIGO and Virgo detectors. We suppose that an event has been seen in coincidence using a filter applied on the three detector data streams. Using the arrival time (and its associated error) of the gravitational signal in each detector, the direction of the source in the sky is computed using a χ 2 minimization technique. For reasonably large signals (SNR>4.5 in all detectors), the mean angular error between the real location and the reconstructed one is about 1 deg. . We also investigate the effect of the network geometry assuming the same angular response for all interferometric detectors. It appears that the reconstruction quality is not uniform over the sky and is degraded when the source approaches the plane defined by the three detectors. Adding at least one other detector to the LIGO-Virgo network reduces the blind regions and in the case of 6 detectors, a precision less than 1 deg. on the source direction can be reached for 99% of the sky

  10. Acoustic emission source location in plates using wavelet analysis and cross time frequency spectrum.

    Science.gov (United States)

    Mostafapour, A; Davoodi, S; Ghareaghaji, M

    2014-12-01

    In this study, the theories of wavelet transform and cross-time frequency spectrum (CTFS) are used to locate AE source with frequency-varying wave velocity in plate-type structures. A rectangular array of four sensors is installed on the plate. When an impact is generated by an artificial AE source such as Hsu-Nielsen method of pencil lead breaking (PLB) at any position of the plate, the AE signals will be detected by four sensors at different times. By wavelet packet decomposition, a packet of signals with frequency range of 0.125-0.25MHz is selected. The CTFS is calculated by the short-time Fourier transform of the cross-correlation between considered packets captured by AE sensors. The time delay is calculated when the CTFS reaches the maximum value and the corresponding frequency is extracted per this maximum value. The resulting frequency is used to calculate the group velocity of wave velocity in combination with dispersive curve. The resulted locating error shows the high precision of proposed algorithm. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Solving seismological problems using SGRAPH program: I-source parameters and hypocentral location

    International Nuclear Information System (INIS)

    Abdelwahed, Mohamed F.

    2012-01-01

    SGRAPH program is considered one of the seismological programs that maintain seismic data. SGRAPH is considered unique for being able to read a wide range of data formats and manipulate complementary tools in different seismological subjects in a stand-alone Windows-based application. SGRAPH efficiently performs the basic waveform analysis and solves advanced seismological problems. The graphical user interface (GUI) utilities and the Windows facilities such as, dialog boxes, menus, and toolbars simplified the user interaction with data. SGRAPH supported the common data formats like, SAC, SEED, GSE, ASCII, and Nanometrics Y-format, and others. It provides the facilities to solve many seismological problems with the built-in inversion and modeling tools. In this paper, I discuss some of the inversion tools built-in SGRAPH related to source parameters and hypocentral location estimation. Firstly, a description of the SGRAPH program is given discussing some of its features. Secondly, the inversion tools are applied to some selected events of the Dahshour earthquakes as an example of estimating the spectral and source parameters of local earthquakes. In addition, the hypocentral location of these events are estimated using the Hypoinverse 2000 program operated by SGRAPH.

  12. Long Period (LP) volcanic earthquake source location at Merapi volcano by using dense array technics

    Science.gov (United States)

    Metaxian, Jean Philippe; Budi Santoso, Agus; Laurin, Antoine; Subandriyo, Subandriyo; Widyoyudo, Wiku; Arshab, Ghofar

    2015-04-01

    Since 2010, Merapi shows unusual activity compared to last decades. Powerful phreatic explosions are observed; some of them are preceded by LP signals. In the literature, LP seismicity is thought to be originated within the fluid, and therefore to be representative of the pressurization state of the volcano plumbing system. Another model suggests that LP events are caused by slow, quasi-brittle, low stress-drop failure driven by transient upper-edifice deformations. Knowledge of the spatial distribution of LP events is fundamental for better understanding the physical processes occurring in the conduit, as well as for the monitoring and the improvement of eruption forecasting. LP events recorded at Merapi have a spectral content dominated by frequencies between 0.8 and 3 Hz. To locate the source of these events, we installed a seismic antenna composed of 4 broadband CMG-6TD Güralp stations. This network has an aperture of 300 m. It is located on the site of Pasarbubar, between 500 and 800 m from the crater rim. Two multi-parameter stations (seismic, tiltmeter, S-P) located in the same area, equipped with broadband CMG-40T Güralp sensors may also be used to complete the data of the antenna. The source of LP events is located by using different approaches. In the first one, we used a method based on the measurement of the time delays between the early beginnings of LP events for each array receiver. The observed differences of time delays obtained for each pair of receivers are compared to theoretical values calculated from the travel times computed between grid nodes, which are positioned in the structure, and each receiver. In a second approach, we estimate the slowness vector by using MUSIC algorithm applied to 3-components data. From the slowness vector, we deduce the back-azimuth and the incident angle, which give an estimation of LP source depth in the conduit. This work is part of the Domerapi project funded by French Agence Nationale de la Recherche (https

  13. Influence of sound source location on the behavior and physiology of the precedence effect in cats.

    Science.gov (United States)

    Dent, Micheal L; Tollin, Daniel J; Yin, Tom C T

    2009-08-01

    Psychophysical experiments on the precedence effect (PE) in cats have shown that they localize pairs of auditory stimuli presented from different locations in space based on the spatial position of the stimuli and the interstimulus delay (ISD) between the stimuli in a manner similar to humans. Cats exhibit localization dominance for pairs of transient stimuli with |ISDs| from approximately 0.4 to 10 ms, summing localization for |ISDs| 10 ms, which is the approximate echo threshold. The neural correlates to the PE have been described in both anesthetized and unanesthetized animals at many levels from auditory nerve to cortex. Single-unit recordings from the inferior colliculus (IC) and auditory cortex of cats demonstrate that neurons respond to both lead and lag sounds at ISDs above behavioral echo thresholds, but the response to the lag is reduced at shorter ISDs, consistent with localization dominance. Here the influence of the relative locations of the leading and lagging sources on the PE was measured behaviorally in a psychophysical task and physiologically in the IC of awake behaving cats. At all configurations of lead-lag stimulus locations, the cats behaviorally exhibited summing localization, localization dominance, and breakdown of fusion. Recordings from the IC of awake behaving cats show neural responses paralleling behavioral measurements. Both behavioral and physiological results suggest systematically shorter echo thresholds when stimuli are further apart in space.

  14. Apparatus and method for locating and quantifying or directing a source of ionizing radiation

    International Nuclear Information System (INIS)

    Rogers, W.L.; Wainstock, M.A.

    1976-01-01

    An apparatus and method for locating or directing a source of ionizing radiation such as X-rays, gamma rays, alpha particles, beta particles, etc. are described. The preferred embodiment detects and locates abnormalities of the body such as ocular melanomas by detecting the emission of radiation from a melanoma which has absorbed a radioactive medium. The apparatus includes an ultrasound probe which emits ultrasonic waves along a first axis and detects a returned portion of the waves. The ultrasound probe is associated with a display which displays the returned portion of the waves in the time domain so that suspected abnormalities can be located. The ultrasound probe is used to guide a directional probe for detecting and quantifying ionizing radiation which is equipped with a focusing collimator having a focal point along a second axis. The two probes are supported so that the first and second axes converge at the focal point of the collimator. A range marker is associated with the ultrasonic detector which indicates the point of convergence of the axes on the ultrasonic display permitting guidance of the radiation detecting probe to the suspected abnormality

  15. Consumption of added sugars among US children and adults by food purchase location and food source.

    Science.gov (United States)

    Drewnowski, Adam; Rehm, Colin D

    2014-09-01

    The proposed changes to the Nutrition Facts Label by the US Food and Drug Administration will include information on added sugars for the first time. The objective was to evaluate the sources of added sugars in the diets of a representative sample of US children and adults by food purchase location and food source (eg, food group). This cross-sectional study among 31,035 children, adolescents, and adults aged ≥6 y from the 2003-2004, 2005-2006, 2007-2008, and 2009-2010 NHANES used data from a 24-h dietary recall to evaluate consumption of added sugars. Food locations of origin were identified as stores (supermarket or grocery store), quick-service restaurants/pizza (QSRs), full-service restaurants (FSRs), schools, and others (eg, vending machines or gifts). Added sugars consumption by food purchase location was evaluated by age, family income-to-poverty ratio, and race-ethnicity. Food group sources of added sugars were identified by using the National Cancer Institute food categories. Added sugars accounted for ∼14.1% of total dietary energy. Between 65% and 76% of added sugars came from stores, 6% and 12% from QSRs, and 4% and 6% from FSRs, depending on age. Older adults (aged ≥51 y) obtained a significantly greater proportion of added sugars from stores than did younger adults. Lower-income adults obtained a significantly greater proportion of added sugars from stores than did higher-income adults. Intake of added sugars did not vary by family income among children/adolescents. Soda and energy and sports drinks were the largest food group sources of added sugars (34.4%), followed by grain desserts (12.7%), fruit drinks (8.0%), candy (6.7%), and dairy desserts (5.6%). Most added sugars came from foods obtained from stores. The proposed changes to the Nutrition Facts Label should capture the bulk of added sugars in the US food supply, which suggests that the recommended changes have the potential to reduce added sugars consumption. © 2014 American Society

  16. Monitoring of dispersed smoke-plume layers by determining locations of the data-point clusters

    Science.gov (United States)

    Kovalev, Vladimir; Wold, Cyle; Petkov, Alexander; Min Hao, Wei

    2018-04-01

    A modified data-processing technique of the signals recorded by zenith-directed lidar, which operates in smoke-polluted atmosphere, is discussed. The technique is based on simple transformations of the lidar backscatter signal and the determination of the spatial location of the data point clusters. The technique allows more reliable detection of the location of dispersed smoke layering. Examples of typical results obtained with lidar in a smokepolluted atmosphere are presented.

  17. New approach for location of continuously emitting acoustic emission sources by phase-controlled probe arrays

    International Nuclear Information System (INIS)

    Hoeller, P.; Klein, M.; Waschkies, E.; Deuster, G.

    1991-01-01

    Usually burst-like acoustic emission (AE) is localized by triangulation. For continuous AE, e.g. from leakages, this method is not feasible. Therefore a new method for localization of continuous AE has been developed. It is based on a phase-controlled probe array which consists of many single sensor elements. The AE signals received by the different sensor elements are delayed according to their time-of-flight differences from the source to the single elements of the receiver array. By choosing special combinations of time differences between the array elements the directivity pattern of the sensitivity of the array can be changed, e.g. rotated in the plane of a large plate. Thus, the source direction can be determined by one array. Some preliminary experiments with an artificial noise source, positioned on a large steel plate, have been performed and have demonstrated the feasibility of this approach. (orig.)

  18. The January 2014 Northern Cuba Earthquake Sequence - Unusual Location and Unexpected Source Mechanism Variability

    Science.gov (United States)

    Braunmiller, J.; Thompson, G.; McNutt, S. R.

    2017-12-01

    On 9 January 2014, a magnitude Mw=5.1 earthquake occurred along the Bahamas-Cuba suture at the northern coast of Cuba revealing a surprising seismic hazard source for both Cuba and southern Florida where it was widely felt. Due to its location, the event and its aftershocks (M>3.5) were recorded only at far distances (300+ km) resulting in high-detection thresholds, low location accuracy, and limited source parameter resolution. We use three-component regional seismic data to study the sequence. High-pass filtered seismograms at the closest site in southern Florida are similar in character suggesting a relatively tight event cluster and revealing additional, smaller aftershocks not included in the ANSS or ISC catalogs. Aligning on the P arrival and low-pass filtering (T>10 s) uncovers a surprise polarity flip of the large amplitude surface waves on vertical seismograms for some aftershocks relative to the main shock. We performed regional moment tensor inversions of the main shock and its largest aftershocks using complete three-component seismograms from stations distributed throughout the region to confirm the mechanism changes. Consistent with the GCMT solution, we find an E-W trending normal faulting mechanism for the main event and for one immediate aftershock. Two aftershocks indicate E-W trending reverse faulting with essentially flipped P- and T-axes relative to the normal faulting events (and the same B-axes). Within uncertainties, depths of the two event families are indistinguishable and indicate shallow faulting (<10 km). One intriguing possible interpretation is that both families ruptured the same fault with reverse mechanisms compensating for overshooting. However, activity could also be spatially separated either vertically (with reverse mechanisms possibly below extension) or laterally. The shallow source depth and the 200-km long uplifted chain of islands indicate that larger, shallow and thus potentially tsunamigenic earthquakes could occur just

  19. Determination of the Number of Fixture Locating Points for Sheet Metal By Grey Model

    Directory of Open Access Journals (Sweden)

    Yang Bo

    2017-01-01

    Full Text Available In the process of the traditional fixture design for sheet metal part based on the "N-2-1" locating principle, the number of fixture locating points is determined by trial and error or the experience of the designer. To that end, a new design method based on grey theory is proposed to determine the number of sheet metal fixture locating points in this paper. Firstly, the training sample set is generated by Latin hypercube sampling (LHS and finite element analysis (FEA. Secondly, the GM(1, 1 grey model is constructed based on the established training sample set to approximate the mapping relationship between the number of fixture locating points and the concerned sheet metal maximum deformation. Thirdly, the final number of fixture locating points for sheet metal can be inversely calculated under the allowable maximum deformation. Finally, a sheet metal case is conducted and the results indicate that the proposed approach is effective and efficient in determining the number of fixture locating points for sheet metal.

  20. Inverse approach for determination of the coils location during magnetic stimulation

    International Nuclear Information System (INIS)

    Marinova, Iliana; Kovachev, Ludmil

    2002-01-01

    An inverse approach using neural networks is extended and applied for determination of coils location during magnetic stimulation. The major constructions of magnetic stimulation coils have been investigated. The electric and magnetic fields are modelled using finite element method and integral equation method. The effects of changing the construction of coils and the frequency to the effect of magnetic stimulation are analysed. The results show that the coils for magnetic stimulation characterize with different focality and magnetic field concentration. The proposed inverse approach using neural networks is very useful for determination the spatial position of the stimulation coils especially when the location of the coil system is required to be changed dynamically. (Author)

  1. Apparatus for radiation source depth determination in a material

    International Nuclear Information System (INIS)

    Campbell, P.J.

    1979-01-01

    An apparatus is disclosed for determining the depth of a radiation source within a body of material utilizing a radiation source holder moving the radiation source within the body. A plurality of switches have contacts that are fixed in relation to the movement of the radiation source within the material. Trigger means activates a particular switch at a preselected depth of the radiation source. Means for indicating the activation of a switch would thus produce a signal as a representative of the depth of the radiation source

  2. Outbreaks source: A new mathematical approach to identify their possible location

    Science.gov (United States)

    Buscema, Massimo; Grossi, Enzo; Breda, Marco; Jefferson, Tom

    2009-11-01

    Classical epidemiology has generally relied on the description and explanation of the occurrence of infectious diseases in relation to time occurrence of events rather than to place of occurrence. In recent times, computer generated dot maps have facilitated the modeling of the spread of infectious epidemic diseases either with classical statistics approaches or with artificial “intelligent systems”. Few attempts, however, have been made so far to identify the origin of the epidemic spread rather than its evolution by mathematical topology methods. We report on the use of a new artificial intelligence method (the H-PST Algorithm) and we compare this new technique with other well known algorithms to identify the source of three examples of infectious disease outbreaks derived from literature. The H-PST algorithm is a new system able to project a distances matrix of points (events) into a bi-dimensional space, with the generation of a new point, named hidden unit. This new hidden unit deforms the original Euclidean space and transforms it into a new space (cognitive space). The cost function of this transformation is the minimization of the differences between the original distance matrix among the assigned points and the distance matrix of the same points projected into the bi-dimensional map (or any different set of constraints). For many reasons we will discuss, the position of the hidden unit shows to target the outbreak source in many epidemics much better than the other classic algorithms specifically targeted for this task. Compared with main algorithms known in the location theory, the hidden unit was within yards of the outbreak source in the first example (the 2007 epidemic of Chikungunya fever in Italy). The hidden unit was located in the river between the two village epicentres of the spread exactly where the index case was living. Equally in the second (the 1967 foot and mouth disease epidemic in England), and the third (1854 London Cholera epidemic

  3. Location of aerodynamic noise sources from a 200 kW vertical-axis wind turbine

    Science.gov (United States)

    Ottermo, Fredric; Möllerström, Erik; Nordborg, Anders; Hylander, Jonny; Bernhoff, Hans

    2017-07-01

    Noise levels emitted from a 200 kW H-rotor vertical-axis wind turbine have been measured using a microphone array at four different positions, each at a hub-height distance from the tower. The microphone array, comprising 48 microphones in a spiral pattern, allows for directional mapping of the noise sources in the range of 500 Hz to 4 kHz. The produced images indicate that most of the noise is generated in a narrow azimuth-angle range, compatible with the location where increased turbulence is known to be present in the flow, as a result of the previous passage of a blade and its support arms. It is also shown that a semi-empirical model for inflow-turbulence noise seems to produce noise levels of the correct order of magnitude, based on the amount of turbulence that could be expected from power extraction considerations.

  4. Stress Tolerance Variations in Saccharomyces cerevisiae Strains from Diverse Ecological Sources and Geographical Locations.

    Directory of Open Access Journals (Sweden)

    Yan-Lin Zheng

    Full Text Available The budding yeast Saccharomyces cerevisiae is a platform organism for bioethanol production from various feedstocks and robust strains are desirable for efficient fermentation because yeast cells inevitably encounter stressors during the process. Recently, diverse S. cerevisiae lineages were identified, which provided novel resources for understanding stress tolerance variations and related shaping factors in the yeast. This study characterized the tolerance of diverse S. cerevisiae strains to the stressors of high ethanol concentrations, temperature shocks, and osmotic stress. The results showed that the isolates from human-associated environments overall presented a higher level of stress tolerance compared with those from forests spared anthropogenic influences. Statistical analyses indicated that the variations of stress tolerance were significantly correlated with both ecological sources and geographical locations of the strains. This study provides guidelines for selection of robust S. cerevisiae strains for bioethanol production from nature.

  5. Preprocessor with spline interpolation for converting stereolithography into cutter location source data

    Science.gov (United States)

    Nagata, Fusaomi; Okada, Yudai; Sakamoto, Tatsuhiko; Kusano, Takamasa; Habib, Maki K.; Watanabe, Keigo

    2017-06-01

    The authors have developed earlier an industrial machining robotic system for foamed polystyrene materials. The developed robotic CAM system provided a simple and effective interface without the need to use any robot language between operators and the machining robot. In this paper, a preprocessor for generating Cutter Location Source data (CLS data) from Stereolithography (STL data) is first proposed for robotic machining. The preprocessor enables to control the machining robot directly using STL data without using any commercially provided CAM system. The STL deals with a triangular representation for a curved surface geometry. The preprocessor allows machining robots to be controlled through a zigzag or spiral path directly calculated from STL data. Then, a smart spline interpolation method is proposed and implemented for smoothing coarse CLS data. The effectiveness and potential of the developed approaches are demonstrated through experiments on actual machining and interpolation.

  6. HPSLPred: An Ensemble Multi-Label Classifier for Human Protein Subcellular Location Prediction with Imbalanced Source.

    Science.gov (United States)

    Wan, Shixiang; Duan, Yucong; Zou, Quan

    2017-09-01

    Predicting the subcellular localization of proteins is an important and challenging problem. Traditional experimental approaches are often expensive and time-consuming. Consequently, a growing number of research efforts employ a series of machine learning approaches to predict the subcellular location of proteins. There are two main challenges among the state-of-the-art prediction methods. First, most of the existing techniques are designed to deal with multi-class rather than multi-label classification, which ignores connections between multiple labels. In reality, multiple locations of particular proteins imply that there are vital and unique biological significances that deserve special focus and cannot be ignored. Second, techniques for handling imbalanced data in multi-label classification problems are necessary, but never employed. For solving these two issues, we have developed an ensemble multi-label classifier called HPSLPred, which can be applied for multi-label classification with an imbalanced protein source. For convenience, a user-friendly webserver has been established at http://server.malab.cn/HPSLPred. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Determinants of industrial location : Kingdom of Yugoslavia in the interwar period

    NARCIS (Netherlands)

    Nikolić, Stefan

    2018-01-01

    What determines the location of industry? Using panel data econometrics and a new dataset on interwar Yugoslavia the predictions of three theories—Heckscher-Ohlin, New Economic Geography, and Path Dependence—are quantified and compared. Results show that all three theories mattered and that New

  8. Novel Methods to Determine Feeder Locational PV Hosting Capacity and PV Impact Signatures

    Energy Technology Data Exchange (ETDEWEB)

    Reno, Matthew J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Coogan, Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Seuss, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    Often PV hosting capacity analysis is performed for a limited number of distribution feeders. For medium - voltage distribution feeders, previous results generally analyze less than 20 feeders, and then the results are extrapolated out to similar types of feeders. Previous hosting capacity research has often focused on determining a single value for the hosting capacity for the entire feeder, whereas this research expands previous hosting capacity work to investigate all the regions of the feeder that may allow many different hosting capacity values wit h an idea called locational hosting capacity (LHC)to determine the largest PV size that can be interconnected at different locations (buses) on the study feeders. This report discusses novel methods for analyzing PV interconnections with advanced simulati on methods. The focus is feeder and location - specific impacts of PV that determine the locational PV hosting capacity. Feeder PV impact signature are used to more precisely determine the local maximum hosting capacity of individual areas of the feeder. T he feeder signature provides improved interconnection screening with certain zones that show the risk of impact to the distribution feeder from PV interconnections.

  9. GNSS-based Road Charging Systems - Assessment of Vehicle Location Determination

    DEFF Research Database (Denmark)

    Zabic, Martina

    the collected data from the experiment, in its original for, as it would be used as input for the automated charge calculation process in a road charging system. Furthermore, new methodologies are developed for assessing the performance of the vehicle location determination function in terms of data reliability...

  10. Determining the location and nearest neighbours of aluminium in zeolites with atom probe tomography

    NARCIS (Netherlands)

    Perea, Daniel E.; Arslan, Ilke; Liu, Jia; Ristanovic, Zoran; Kovarik, Libor; Arey, Bruce W.; Lercher, Johannes A.; Bare, Simon R.; Weckhuysen, Bert M.

    Zeolite catalysis is determined by a combination of pore architecture and Bronsted acidity. As Bronsted acid sites are formed by the substitution of AlO4 for SiO4 tetrahedra, it is of utmost importance to have information on the number as well as the location and neighbouring sites of framework

  11. The determinants of the location of foreign direct investment in UK regions

    NARCIS (Netherlands)

    Dimitropoulou, Dimitra; McCann, Philip; Burke, Simon P.

    2013-01-01

    This article employs a database of over 2000 observations of Foreign Direct Investment (FDI) projects in UK regions. We analyse this data by means of various multinomial and conditional logit models in order to identify the major determinants of the location choices of these inward investments.

  12. Location, location, location

    NARCIS (Netherlands)

    Anderson, S.P.; Goeree, J.K.; Ramer, R.

    1997-01-01

    We analyze the canonical location-then-price duopoly game with general log- concave consumer densities. A unique pure-strategy equilibrium to the two-stage game exists if the density is not "too asymmetric" and not "too concave." These criteria are satisfied by many commonly used densities.

  13. Method and system for assigning a confidence metric for automated determination of optic disc location

    Science.gov (United States)

    Karnowski, Thomas P [Knoxville, TN; Tobin, Jr., Kenneth W.; Muthusamy Govindasamy, Vijaya Priya [Knoxville, TN; Chaum, Edward [Memphis, TN

    2012-07-10

    A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.

  14. Automated method for determining location and magnitude of leaks inside a PWR containment

    International Nuclear Information System (INIS)

    Cho, J.H.; Elia, F.A. Jr.

    1986-01-01

    Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. In this way, the plant's computer will be able to measure and locate leaks inside containment. The study concludes that dew point temperature (or relative humidity) is the most suitable parameter for locating a leak while flow rate to sump is the most suitable parameter for quantifying the leak

  15. Sound Spectrum Influences Auditory Distance Perception of Sound Sources Located in a Room Environment

    Directory of Open Access Journals (Sweden)

    Ignacio Spiousas

    2017-06-01

    Full Text Available Previous studies on the effect of spectral content on auditory distance perception (ADP focused on the physically measurable cues occurring either in the near field (low-pass filtering due to head diffraction or when the sound travels distances >15 m (high-frequency energy losses due to air absorption. Here, we study how the spectrum of a sound arriving from a source located in a reverberant room at intermediate distances (1–6 m influences the perception of the distance to the source. First, we conducted an ADP experiment using pure tones (the simplest possible spectrum of frequencies 0.5, 1, 2, and 4 kHz. Then, we performed a second ADP experiment with stimuli consisting of continuous broadband and bandpass-filtered (with center frequencies of 0.5, 1.5, and 4 kHz and bandwidths of 1/12, 1/3, and 1.5 octave pink-noise clips. Our results showed an effect of the stimulus frequency on the perceived distance both for pure tones and filtered noise bands: ADP was less accurate for stimuli containing energy only in the low-frequency range. Analysis of the frequency response of the room showed that the low accuracy observed for low-frequency stimuli can be explained by the presence of sparse modal resonances in the low-frequency region of the spectrum, which induced a non-monotonic relationship between binaural intensity and source distance. The results obtained in the second experiment suggest that ADP can also be affected by stimulus bandwidth but in a less straightforward way (i.e., depending on the center frequency, increasing stimulus bandwidth could have different effects. Finally, the analysis of the acoustical cues suggests that listeners judged source distance using mainly changes in the overall intensity of the auditory stimulus with distance rather than the direct-to-reverberant energy ratio, even for low-frequency noise bands (which typically induce high amount of reverberation. The results obtained in this study show that, depending on

  16. Oil pollution and microbiological quality of groundwater at the location of the water source 'Ratno ostrvo' nearby Novi Sad

    International Nuclear Information System (INIS)

    Petrovic, O.; Simeunovic, J.; Radnovic, D.; Matavulj, M.; Gajin, S.

    2002-01-01

    The 'Ratno ostrvo' is the biggest drinking water source in wider area of Novi Sad. It is located on the left bank of the river Danube near the Oil Refinery 'Novi Sad'. One of the consequences of the NATO bombing of the Oil Refinery 'Novi Sad' (which is placed in hinterland of the water source) was the uncontrolled spillage of crude oil and oil derivatives. Because of that, microbiological examinations of groundwaters, from both ecological and sanitary aspects were carried out simultaneously during post-war period. Microbiological analyses from sanitary aspects show very low number of coliform bacteria. Determination of numbers of bacteria of the investigated physiological groups, revealed that there was a constant relatively high number of oil-, phenol oxidizing and lipolytic bacteria which are indicators this kind of specific pollution. Microbiological analysis of oil polluted soil show presence relatively high number of different groups of bacteria. In spite of changed ecological situation caused by war effects, microbiological analyses of groundwater quality showed satisfactory results in source 'Ratno ostrvo' by now. The presence and potential activity of indigenous microflora could be utilized in recultivation processes in examined area. (author)

  17. Seismic precursors of vulcanian explosions at Ubinas volcano (Peru) : Statistical analysis and source locations

    Science.gov (United States)

    Métaxian, J.-P.; Macedo, O.; Lengline, O.; Monteiller, V.; Taipe, E.

    2009-04-01

    Ubinas stratovolcano (5672 m), located 60 km east from Arequipa city is historically the most active volcano in Peru. The present eruption began on March 25th 2006. A lava plug has been observed at the bottom of the pit crater situated in the south part of the caldeira. The eruptive activity involves very brought closer exhalations rising a few hundred meters above the crater rim to larger plumes produced by explosions that may reach up to 3 kilometers. The seismic activity is characterized by high rates of long-period (LP) event production accompanying eruptive activity and very long period (VLP) events observed at the same time as vulcanian explosions. The LP and VLP events have a spectral content respectively dominated by frequencies between 2-5 Hz and 0.3-0.9 Hz. The vulcanian explosive activity is characterized by the occurrence of LP swarm preceding most of the VLPs by about 2 hours. In some occasions, the LP swarm merges into tremor about half an hour before the explosion. LPs belonging to the same swarm have similar waveform suggesting a unique source area, which could be the conduit and/or the lava plug surface. The monitoring system includes 4 seismic stations, among which one is equipped with a broadband sensor and 2 tiltmeters. In this work we analyzed a catalogue of data including more than 40000 LP events and 130 VLP events recorded between May 2006 and December 2008. The evolution of the average number of LP events preceding explosions was computed. The variation of the LP rate is clearly diverging from the background rate ~ 0.1 days before explosions. In particular, the most energetic explosions are correlated with the biggest increases of seismicity. However this general behavior is not observed for every single explosion. A direct test is now under study in order to check if the earthquake rate can be used as an alert tool for future explosions. To locate the source of LP events belonging to the swarms, we used a method based on the measurement of

  18. Testing seismic amplitude source location for fast debris-flow detection at Illgraben, Switzerland

    Science.gov (United States)

    Walter, Fabian; Burtin, Arnaud; McArdell, Brian W.; Hovius, Niels; Weder, Bianca; Turowski, Jens M.

    2017-06-01

    Heavy precipitation can mobilize tens to hundreds of thousands of cubic meters of sediment in steep Alpine torrents in a short time. The resulting debris flows (mixtures of water, sediment and boulders) move downstream with velocities of several meters per second and have a high destruction potential. Warning protocols for affected communities rely on raising awareness about the debris-flow threat, precipitation monitoring and rapid detection methods. The latter, in particular, is a challenge because debris-flow-prone torrents have their catchments in steep and inaccessible terrain, where instrumentation is difficult to install and maintain. Here we test amplitude source location (ASL) as a processing scheme for seismic network data for early warning purposes. We use debris-flow and noise seismograms from the Illgraben catchment, Switzerland, a torrent system which produces several debris-flow events per year. Automatic in situ detection is currently based on geophones mounted on concrete check dams and radar stage sensors suspended above the channel. The ASL approach has the advantage that it uses seismometers, which can be installed at more accessible locations where a stable connection to mobile phone networks is available for data communication. Our ASL processing uses time-averaged ground vibration amplitudes to estimate the location of the debris-flow front. Applied to continuous data streams, inversion of the seismic amplitude decay throughout the network is robust and efficient, requires no manual identification of seismic phase arrivals and eliminates the need for a local seismic velocity model. We apply the ASL technique to a small debris-flow event on 19 July 2011, which was captured with a temporary seismic monitoring network. The processing rapidly detects the debris-flow event half an hour before arrival at the outlet of the torrent and several minutes before detection by the in situ alarm system. An analysis of continuous seismic records furthermore

  19. Testing seismic amplitude source location for fast debris-flow detection at Illgraben, Switzerland

    Directory of Open Access Journals (Sweden)

    F. Walter

    2017-06-01

    Full Text Available Heavy precipitation can mobilize tens to hundreds of thousands of cubic meters of sediment in steep Alpine torrents in a short time. The resulting debris flows (mixtures of water, sediment and boulders move downstream with velocities of several meters per second and have a high destruction potential. Warning protocols for affected communities rely on raising awareness about the debris-flow threat, precipitation monitoring and rapid detection methods. The latter, in particular, is a challenge because debris-flow-prone torrents have their catchments in steep and inaccessible terrain, where instrumentation is difficult to install and maintain. Here we test amplitude source location (ASL as a processing scheme for seismic network data for early warning purposes. We use debris-flow and noise seismograms from the Illgraben catchment, Switzerland, a torrent system which produces several debris-flow events per year. Automatic in situ detection is currently based on geophones mounted on concrete check dams and radar stage sensors suspended above the channel. The ASL approach has the advantage that it uses seismometers, which can be installed at more accessible locations where a stable connection to mobile phone networks is available for data communication. Our ASL processing uses time-averaged ground vibration amplitudes to estimate the location of the debris-flow front. Applied to continuous data streams, inversion of the seismic amplitude decay throughout the network is robust and efficient, requires no manual identification of seismic phase arrivals and eliminates the need for a local seismic velocity model. We apply the ASL technique to a small debris-flow event on 19 July 2011, which was captured with a temporary seismic monitoring network. The processing rapidly detects the debris-flow event half an hour before arrival at the outlet of the torrent and several minutes before detection by the in situ alarm system. An analysis of continuous seismic

  20. A new power mapping method based on ordinary kriging and determination of optimal detector location strategy

    International Nuclear Information System (INIS)

    Peng, Xingjie; Wang, Kan; Li, Qing

    2014-01-01

    Highlights: • A new power mapping method based on Ordinary Kriging (OK) is proposed. • Measurements from DayaBay Unit 1 PWR are used to verify the OK method. • The OK method performs better than the CECOR method. • An optimal neutron detector location strategy based on ordinary kriging and simulated annealing is proposed. - Abstract: The Ordinary Kriging (OK) method is presented that is designed for a core power mapping calculation of pressurized water reactors (PWRs). Measurements from DayaBay Unit 1 PWR are used to verify the accuracy of the OK method. The root mean square (RMS) reconstruction errors are kept at less than 0.35%, and the maximum reconstruction relative errors (RE) are kept at less than 1.02% for the entire operating cycle. The reconstructed assembly power distribution results show that the OK method is fit for core power distribution monitoring. The quality of power distribution obtained by the OK method is partly determined by the neutron detector locations, and the OK method is also applied to solve the optimal neutron detector location problem. The spatially averaged ordinary kriging variance (AOKV) is minimized using simulated annealing, and then, the optimal in-core neutron detector locations are obtained. The result shows that the current neutron detector location of DayaBay Unit 1 reactor is near-optimal

  1. INEMO: Distributed RF-Based Indoor Location Determination with Confidence Indicator

    Directory of Open Access Journals (Sweden)

    Youxian Sun

    2007-12-01

    Full Text Available Using radio signal strength (RSS in sensor networks localization is an attractive method since it is a cost-efficient method to provide range indication. In this paper, we present a two-tier distributed approach for RF-based indoor location determination. Our approach, namely, INEMO, provides positioning accuracy of room granularity and office cube granularity. A target can first give a room granularity request and the background anchor nodes cooperate to accomplish the positioning process. Anchors in the same room can give cube granularity if the target requires further accuracy. Fixed anchor nodes keep monitoring status of nearby anchors and local reference matching is used to support room separation. Furthermore, we utilize the RSS difference to infer the positioning confidence. The simulation results demonstrate the efficiency of the proposed RF-based indoor location determination.

  2. A mathematical model for leak location and leak area determination in pipeline networks

    Directory of Open Access Journals (Sweden)

    Oyedokun O.I.

    2013-01-01

    Full Text Available Prompt leak location and leak area determination in oil and gas pipeline installations is an indispensable approach to controlling petroleum products wastages in pipes. However, there is an evident lack of literature information on this subject. In this paper, we modelled leak location detection and leak area determination in pipes by applying two methodologies and gave an illustrative example using simulated data with the aid of Matlab. A comparison of these two approaches resulted in an error of 6.24%, suggesting that the closer the leak is to the measurement station, the lower will be the time interval between two successive waves that will pass through the leak and get to the measurement station. The relationship between the pipe area and coefficient of reflection is parabolic. This contribution is valuable to pipeline engineers in the economic control of leaks.

  3. A Panel data analysis of locational determinants of outward Foreign Direct Investment from China and India

    OpenAIRE

    Duanmu, J; Guney, Y

    2009-01-01

    The upsurge of Chinese and Indian outward foreign direct investment (FDI) raises an unanswered question about locational determinants of direct investment from the two countries. Using an unbalanced bilateral FDI database, we find that Chinese and Indian FDI are attracted to countries with large market size, low GDP growth, high volumes of imports from China or India, and low corporate tax rates. We also find important differences between China and India. While Chinese FDI is drawn to countri...

  4. Locating non-volcanic tremor along the San Andreas Fault using a multiple array source imaging technique

    Science.gov (United States)

    Ryberg, T.; Haberland, C.H.; Fuis, G.S.; Ellsworth, W.L.; Shelly, D.R.

    2010-01-01

    Non-volcanic tremor (NVT) has been observed at several subduction zones and at the San Andreas Fault (SAF). Tremor locations are commonly derived by cross-correlating envelope-transformed seismic traces in combination with source-scanning techniques. Recently, they have also been located by using relative relocations with master events, that is low-frequency earthquakes that are part of the tremor; locations are derived by conventional traveltime-based methods. Here we present a method to locate the sources of NVT using an imaging approach for multiple array data. The performance of the method is checked with synthetic tests and the relocation of earthquakes. We also applied the method to tremor occurring near Cholame, California. A set of small-aperture arrays (i.e. an array consisting of arrays) installed around Cholame provided the data set for this study. We observed several tremor episodes and located tremor sources in the vicinity of SAF. During individual tremor episodes, we observed a systematic change of source location, indicating rapid migration of the tremor source along SAF. ?? 2010 The Authors Geophysical Journal International ?? 2010 RAS.

  5. Method for Determining Appropriate Clustering Criteria of Location-Sensing Data

    Directory of Open Access Journals (Sweden)

    Youngmin Lee

    2016-08-01

    Full Text Available Large quantities of location-sensing data are generated from location-based social network services. These data are provided as point properties with location coordinates acquired from a global positioning system or Wi-Fi signal. To show the point data on multi-scale map services, the data should be represented by clusters following a grid-based clustering method, in which an appropriate grid size should be determined. Currently, there are no criteria for determining the proper grid size, and the modifiable areal unit problem has been formulated for the purpose of addressing this issue. The method proposed in this paper is applies a hexagonal grid to geotagged Twitter point data, considering the grid size in terms of both quantity and quality to minimize the limitations associated with the modifiable areal unit problem. Quantitatively, we reduced the original Twitter point data by an appropriate amount using Töpfer’s radical law. Qualitatively, we maintained the original distribution characteristics using Moran’s I. Finally, we determined the appropriate sizes of clusters from zoom levels 9–13 by analyzing the distribution of data on the graphs. Based on the visualized clustering results, we confirm that the original distribution pattern is effectively maintained using the proposed method.

  6. Load flow analysis for determining the location of NPP power distribution in West Kalimantan

    International Nuclear Information System (INIS)

    Citra Candranurani; Rizki Finnansyah Setya Budi; Sahala M Lumbanraja

    2015-01-01

    Electricity crisis condition happened in West Kalimantan (Kalbar) as a result of power plant capacity almost equal to the peak load. The system will experience a shortfall if there are plants that not operating and do not have reserve. The policy of electricity planning until 2022 is replacing diesel power plant with steam power plant. For long-term planning is required the role of new and renewable energy in order to reduce dependency on fossil fuel consumption, such as NPP utilization. The purpose of this study was to determine the optimum location of the NPP power distribution in order to prepare electricity infrastructure. Load flow calculation in this study using ETAP 12.5 software. NPP is planned to supply base load, so the optimum capacity factor is above 80 %. The result show that there are three location where NPP can generate over 80 % of its capacity, namely: Mempawah Substation, Singkawang Substation, and Sambas Substation. The most optimum located in Mempawah Substation with capacity factor 83.5 %. The location of the three Substation are onshore and in line with one requirement for NPP construction, namely: the availability of cooling water. (author)

  7. Socioeconomic assessment guidance report: Determining the effects of amenity characteristics on business location decisions

    International Nuclear Information System (INIS)

    Allison, T.

    1993-02-01

    Evaluating perception-based impacts of hazardous waste facilities has become an increasingly important part of socioeconomic impact assessments in recent years. One area of discussion has been the potential effect of risk perceptions on business location decision making. This report evaluates the importance of environmental amenities (broadly defined to include natural, cultural, and recreational features; environmental quality; and other indexes of quality of life) with respect to decisions on locating both manufacturing and business service activities. It discusses the major theoretical and empirical issues that arise in attempting to determine the effects of environmental amenities on the location choices for businesses and business activities. This discussion is followed by a survey of major findings from the academic literature and a review of research by the state of Nevada. A number of recommendations for further research are also provided to help the US Department of Energy's Office of Civilian Radioactive Waste Management better understand the importance of perception-based impacts in business location decision making and estimate the scale of socioeconomic impacts that would result from siting a high-level waste repository in Nevada

  8. Socioeconomic assessment guidance report: Determining the effects of amenity characteristics on business location decisions

    Energy Technology Data Exchange (ETDEWEB)

    Allison, T.

    1993-02-01

    Evaluating perception-based impacts of hazardous waste facilities has become an increasingly important part of socioeconomic impact assessments in recent years. One area of discussion has been the potential effect of risk perceptions on business location decision making. This report evaluates the importance of environmental amenities (broadly defined to include natural, cultural, and recreational features; environmental quality; and other indexes of quality of life) with respect to decisions on locating both manufacturing and business service activities. It discusses the major theoretical and empirical issues that arise in attempting to determine the effects of environmental amenities on the location choices for businesses and business activities. This discussion is followed by a survey of major findings from the academic literature and a review of research by the state of Nevada. A number of recommendations for further research are also provided to help the US Department of Energy`s Office of Civilian Radioactive Waste Management better understand the importance of perception-based impacts in business location decision making and estimate the scale of socioeconomic impacts that would result from siting a high-level waste repository in Nevada.

  9. Source Population and Acceleration Location of Suprathermal Heavy Ions in Corotating Interaction Regions

    Energy Technology Data Exchange (ETDEWEB)

    Filwett, R. J.; Desai, M. I. [University of Texas at San Antonio, San Antonio, TX (United States); Dayeh, M. A.; Broiles, T. W. [Southwest Research Institute, San Antonio, TX (United States)

    2017-03-20

    We have analyzed the ∼20–320 keV nucleon{sup −1} suprathermal (ST) heavy ion abundances in 41 corotating interaction regions (CIRs) observed by the Wind spacecraft from 1995 January to 2008 December. Our results are: (1) the CIR Fe/CNO and NeS/CNO ratios vary with the sunspot number, with values being closer to average solar energetic particle event values during solar maxima and lower than nominal solar wind values during solar minima. The physical mechanism responsible for the depleted abundances during solar minimum remains an open question. (2) The Fe/CNO increases with energy in the 6 events that occurred during solar maximum, while no such trends are observed for the 35 events during solar minimum. (3) The Fe/CNO shows no correlation with the average solar wind speed. (4) The Fe/CNO is well correlated with the corresponding upstream ∼20–320 keV nucleon{sup −1} Fe/CNO and not with the solar wind Fe/O measured by ACE in 31 events. Using the correlations between the upstream ∼20–40 keV nucleon{sup −1} Fe/CNO and the ∼20–320 keV nucleon{sup −1} Fe/CNO in CIRs, we estimate that, on average, the ST particles traveled ∼2 au along the nominal Parker spiral field line, which corresponds to upper limits for the radial distance of the source or acceleration location of ∼1 au beyond Earth orbit. Our results are consistent with those obtained from recent surveys, and confirm that CIR ST heavy ions are accelerated more locally, and are at odds with the traditional viewpoint that CIR ions seen at 1 au are bulk solar wind ions accelerated between 3 and 5 au.

  10. Determination of the Earth's Plasmapause Location from the CE-3 EUVC Images

    Science.gov (United States)

    He, Fei; Zhang, Xiao-Xin; Chen, Bo; Fok, Mei-Ching; Nakano, Shinya

    2016-01-01

    The Moon-based Extreme Ultraviolet Camera (EUVC) aboard China's Chang'e-3 (CE-3) mission has successfully imaged the entire Earth's plasmasphere for the first time from the side views on lunar surface. An EUVC image on 21 April 2014 is used in this study to demonstrate the characteristics and configurations of the Moon-based EUV imaging and to illustrate the determination algorithm of the plasmapause locations on the magnetic equator. The plasmapause locations determined from all the available EUVC images with the Minimum L Algorithm are quantitatively compared with those extracted from insitu observations (Defense Meteorological Satellite Program, Time History of Events and Macroscale Interactions during Substorms, and Radiation Belt Storm Probes). Excellent agreement between the determined plasmapauses seen by EUVC and the extracted ones from other satellites indicates the reliability of the Moon-based EUVC images as well as the determination algorithm. This preliminary study provides an important basis for future investigation of the dynamics of the plasmasphere with the Moon-based EUVC imaging.

  11. Source contributions to PM2.5 and PM10 at an urban background and a street location

    Science.gov (United States)

    Keuken, M. P.; Moerman, M.; Voogt, M.; Blom, M.; Weijers, E. P.; Röckmann, T.; Dusek, U.

    2013-06-01

    The contribution of regional, urban and traffic sources to PM2.5 and PM10 in an urban area was investigated in this study. The chemical composition of PM2.5 and PM10 was measured over a year at a street location and up- and down-wind of the city of Rotterdam, the Netherlands. The 14C content in EC and OC concentrations was also determined, to distinguish the contribution from "modern" carbon (e.g., biogenic emissions, biomass burning and wildfires) and fossil fuel combustion. It was concluded that the urban background of PM2.5 and PM10 is dominated by the regional background, and that primary and secondary PM emission by urban sources contribute less than 15%. The 14C analysis revealed that 70% of OC originates from modern carbon and 30% from fossil fuel combustion. The corresponding percentages for EC are, respectively 17% and 83%. It is concluded that in particular the urban population living in street canyons with intense road traffic has potential health risks. This is due to exposure to elevated concentrations of a factor two for EC from exhaust emissions in PM2.5 and a factor 2-3 for heavy metals from brake and tyre wear, and re-suspended road dust in PM10. It follows that local air quality management may focus on local measures to street canyons with intense road traffic.

  12. Determinants, obstacles, sources and cooperation to innovation in Portuguese firms, using community innovation survey

    Science.gov (United States)

    Correia, Aldina; Braga, Alexandra; Braga, Vitor

    2017-06-01

    Innovation is a topic of interest for the management researchers, confirmed by the creation of a Community Innovation Survey, which is an harmonised tool designed to provide information about Innovation in European Union enterprises. In this study, we use factorial analysis to identify the determinants and obstacles to innovation in Portuguese firms. The sources of innovation and cooperation to innovation are also analysed, using crossed information. For the determinants of innovation six factors were identified: Production costs and impacts to health and environment, Process and product innovation, Organizational innovation, Institutional sources of information, Others sources of information and Market sources of information. Obstacles to innovation were clustered into three groups: Knowledge and market factors, Cost factors and Reasons not to innovate. The main sources of innovation identified, in this study, are Suppliers and Clients, located in Portugal and in Europe. Cooperation partners are also majority Clients and Suppliers, in addition to other enterprises in the same group.

  13. Determination of Effective Criteria for Location Selection of Kiln Wood Drying Plants by AHP Technique

    Directory of Open Access Journals (Sweden)

    Rahim Mohebbi

    2011-12-01

    Full Text Available This study was aimed at determining the effective criteria for location selection of wood drying plants in Iran. For this purpose, after review and field visit of the industries, 35 key indicators were identified. These criteria were divided into five major groups as: materials, infrastructure, technical, economical and instructional indices. The priority rates of these criteria and sub-criteria were evaluated by AHP technique. The results indicated that among 35 effective sub-criteria in location selection of the plants, the sub-criteria of quality of raw materials(0.152, purchasing raw materials, land cost, profitability, reliability of supply, and sales had the highest priorities, which were rated as 0.118, 0.105, 0.067, 0.061 and 0.057, respectively

  14. Groundwater drilling location determination in Girirejo Village, Tempuran Sub-District, Magelang

    International Nuclear Information System (INIS)

    FD Indrastomo; I Gde Sukadana

    2010-01-01

    Girirejo Village is one of the villages in Tempuran Sub-district, Magelang Regency which have fresh water difficulty. Determination of groundwater drilling location conducted with phases of activity include desk study stage, topographic data collection, geology and hydrogeology mapping, geo electrical surveys, and integrated analysis. Based on the results of field geological mapping, it is found that the area is composed of three rock units, namely andesite, breccia tuff and sandy tuff. Results of rock resistivity measurements show the value of resistivity 16 - 32 ohm-m are interpreted as sandy tuff with wet conditions, and the value of resistivity 60 - 80 ohm-m is interpreted as a breccia. Location TMG-14 at depths of 1.6 - 29.1 m by 27.5 m thick aquifer is a potential point which next recommended as potential sites of groundwater drilling. (author)

  15. Determination of the water quality and radon content in wells located at the Cuitzeo basin, Michoacan

    International Nuclear Information System (INIS)

    Alfaro, R.; Segovia, N.; Pena, P.; Lopez, M.B.E.; Martinez, V.; Armienta, M.A.; Rangel, J.; Seidel, J.L.

    2001-01-01

    Major elements, trace elements, presence of microorganisms and, radon content in wells located in urban and rural zones around the Cuitzeo lake at the Lerma River basin in Mexico were determined. The techniques to determine the parameters were the liquid scintillation method for 222 Rn, Icp-Ms for trace elements, conventional chemical analysis for major components and the counting in slide for the bacteriological determination. The average concentration of radon oscillated between 0.88 and 4.75 Bq/lt which, indicated a fast transit from the reload toward the spring exit. The major components and trace elements are analysed considering the geological characteristics of the sites in study. Faecal coliforms were not found. (Author)

  16. Gas Well Top Hole Locations, LP and LNG - Marcellus Gas Well Water Sources View

    Data.gov (United States)

    NSGIC Education | GIS Inventory — This data set contains all approved water sources within water managment plans (WMP). A WMP contains water sources utilized in the fracture stimulation of Marcellus...

  17. New electronic apex locator Romiapex A-15 presented accuracy for working length determination in permanent teeth

    Directory of Open Access Journals (Sweden)

    Etevaldo Matos Maia Filho

    2014-12-01

    Full Text Available Purpose: The present study aims to evaluate, ex vivo, the accuracy of electronic apex locators Root ZX II and Romiapex-15, for working length (WL determination in permanent teeth. Materials and Methods: Fourteen single-rooted teeth (incisors and canines, with their apices fully formed were used. The dental crowns were removed. The anatomic length of the tooth (real measurement was visually determined through the insertion of a size 10 K-file until the tip of the instrument could be observed in the apical foramen under a microscope (20X. Teeth were fixed in a model of resin and adapted into alginate soaked with saline solution, which was used as an  electrical conductor. Using a K-file, root canals were measured electronically using both devices. The results obtained for each apex locator were compared to the real measurements. The accuracy between the devices was statistically analyzed using the Bland-Altman graph, Intraclass Correlation Coefficient (ICC, and Student’s t-test. Results: The mean difference between the measurements using the Root ZX II was 0.277mm greater than the real measurement, while the measurements from the Romiapex-15 were 0.308mm higher on average. The comparison between Root ZX II and Romiapex-15 had no significant difference (p= 0.868. Conclusion: It was concluded that Root ZX II and Romiapex-15 had similar accuracy. Romiapex-15 could be an option for WL determination in permanent teeth.

  18. Joint sensor location/power rating optimization for temporally-correlated source estimation

    KAUST Repository

    Bushnaq, Osama M.; Chaaban, Anas; Al-Naffouri, Tareq Y.

    2017-01-01

    via wireless AWGN channel. In addition to selecting the optimal sensing location, the sensor type to be placed in these locations is selected from a pool of T sensor types such that different sensor types have different power ratings and costs

  19. Strategic Sourcing of R&D: The Determinants of Success

    Science.gov (United States)

    Brook, Jacques W.; Plugge, Albert

    The outsourcing of the R&D function is an emerging practice of corporate firms. In their attempt to reduce the increasing cost of research and technology development, firms are strategically outsourcing the R&D function or repositioning their internal R&D organisation. By doing so, they are able to benefit from other technology sources around the world. So far, there is only limited research on how firms develop their R&D sourcing strategies and how these strategies are implemented. This study aims to identify which determinants contribute to the success of R&D sourcing strategies. The results of our empirical research indicate that a clear vision of how to manage innovation strategically on a corporate level is a determinant of an effective R&D strategy. Moreover, our findings revealed that the R&D sourcing strategy influences a firm's sourcing capabilities. These sourcing capabilities need to be developed to manage the demand as well as the supply of R&D services. The alignment between the demand capabilities and the supply capabilities contributes to the success of R&D sourcing.

  20. Comparative analysis of diffused solar radiation models for optimum tilt angle determination for Indian locations

    International Nuclear Information System (INIS)

    Yadav, P.; Chandel, S.S.

    2014-01-01

    Tilt angle and orientation greatly are influenced on the performance of the solar photo voltaic panels. The tilt angle of solar photovoltaic panels is one of the important parameters for the optimum sizing of solar photovoltaic systems. This paper analyses six different isotropic and anisotropic diffused solar radiation models for optimum tilt angle determination. The predicted optimum tilt angles are compared with the experimentally measured values for summer season under outdoor conditions. The Liu and Jordan model is found to exhibit t lowest error as compared to other models for the location. (author)

  1. Assessment of environmental gamma radiation levels at locations having different source characteristics using TLDs

    International Nuclear Information System (INIS)

    Sahu, S.K.; Swarnkar, M.; Takale, R.A.; Shetty, P.G.; Pandit, G.G.; Puranik, V.D.

    2012-01-01

    Naturally occurring radionuclides are the major contributor to the total effective dose of ionizing radiation received by the population (UNSCEAR, 1993). The dose in environment thus depends largely on natural radiation than manmade or artificially produced radiation. In the last few decades, there is a growing concern all over the world about radiation and their exposure to population. Thus, it is a necessity to conduct frequent radiological environmental surveillance in order to assess population exposure accurately. Recently, application of thermoluminescence dosimeters (TLDs) has been extended to the measurement of mixed radiation field as encountered in the environment. The advantages of passive TL dosimeters for environmental monitoring are that they are small, cheap and do not require power supply during application. The passive TL dosimeters play an important role to provide data on natural background radiation and to determine the contribution to the dose to public from man-made sources. In the present study, three different sites were chosen to compare environmental gamma radiation levels in different scenarios. Kaiga has been chosen as site 1, where four unit of pressurized heavy water reactor (PHWR) of 220 MWe each are in operation. Site 2 is chosen at natural high background radiation area (NHBRA) of Kerala and Vishakhapatnam was chosen as site 3, which is situated at a normal background area. The objective of the study is to illustrate the effect, if any, of an operating nuclear power reactor on environmental gamma radiation levels

  2. Depth determination of buried caesium-137 and cobalt-60 sources using scatter peak data

    International Nuclear Information System (INIS)

    Adams, J. C.; Joyce, M. J.; Mellor, M.

    2009-01-01

    An investigation into an alternative approach to 3D (3-dimensional) source mapping is proposed, by combining the insights of two existing techniques. The first of these is a 3D 'imaging' tool, N-Visage TM that has been developed by REACT Engineering Ltd. This technique is efficient and robust, but is not a true 3D technique as it relies on user-supplied 2D (2-dimensional) manifolds to constrain source locations. The second technique uses the γ-photopeak and an X-ray peak to determine radionuclide source depth using a relative attenuation method. We look at the possibility of combining both techniques to constrain both the location and depth of a radiological source buried under shielding. It is believed a combined method using spectra recorded above the shielding object will be of use in the nuclear decommissioning and land contamination industries. N-Visage TM has previously been used to map source distributions of mixed radionuclides with complex geometries through shielding media. The software works by producing a computer model which recreates the experimental setup. A survey is imported, comprising a set of γ-spectra recorded with an instrument of known efficiency and isotropy taken at a variety of locations around the area of interest. A survey plan recording the location and orientation of the instrument for each reading is also reconstructed. N-Visage TM is then able to determine the locations of the source(s) without prior knowledge of exactly where they are located, by building and inverting a simple physical model relating potential source locations to the recorded spectra. This research sets out to investigate the possibility of combining the geometric insights of N-Visage TM with a method of extracting depth information from scatter data, rather than the X-ray peak. By combining the γ-photopeak and scatter areas of a spectrum, the thickness of the shielding media between source and detector can potentially be inferred. Using scattered photons rather

  3. A Compton scattering technique to determine wood density and locating defects in it

    International Nuclear Information System (INIS)

    Tondon, Akash; Sandhu, B. S.; Singh, Bhajan; Singh, Mohinder

    2015-01-01

    A Compton scattering technique is presented to determine density and void location in the given wooden samples. The technique uses a well collimated gamma ray beam from 137 Cs along with the NaI(Tl) scintillation detector. First, a linear relationship is established between Compton scattered intensity and known density of chemical compounds, and then density of the wood is determined from this linear relation. In another experiment, the ability of penetration of gamma rays is explored to detect voids in wooden (low Z) sample. The sudden reduction in the Compton scattered intensities agrees well with the position and size of voids in the wooden sample. It is concluded that wood density and the voids of size ∼ 4 mm and more can be detected easily by this method

  4. In vitro comparison of working length determination using three different electronic apex locators

    Directory of Open Access Journals (Sweden)

    Alper Kuştarci

    2014-01-01

    Full Text Available Background: The aim of this study was to compare the accuracy of the apex-locating functions of DentaPort ZX, Raypex 5 and Endo Master electronic apex locators (EALs in vitro. Materials and Methods: Thirty extracted human single-rooted teeth with mature apices were used for the study. The real working length (RWL was established by subtracting 0.5 mm from the actual root canal length. All teeth were mounted in an alginate model that was especially developed to test the EALs and the teeth were then measured with each EAL. The results were compared with the corresponding RWL, which was subtracted from the electronically determined distance. Data were analyzed using a paired-samples t-test, a Chi-square test and a repeated measure analysis of variance evaluation at the 0.05 level of significance. Results: Statistical analysis showed that no significant difference was found among all EALs (P > 0.05. Conclusion: The accuracy of the EALs was evaluated and all of the devices showed an acceptable determination of electronic working length between the ranges of ±0.5 mm.

  5. Joint sensor location/power rating optimization for temporally-correlated source estimation

    KAUST Repository

    Bushnaq, Osama M.

    2017-12-22

    The optimal sensor selection for scalar state parameter estimation in wireless sensor networks is studied in the paper. A subset of N candidate sensing locations is selected to measure a state parameter and send the observation to a fusion center via wireless AWGN channel. In addition to selecting the optimal sensing location, the sensor type to be placed in these locations is selected from a pool of T sensor types such that different sensor types have different power ratings and costs. The sensor transmission power is limited based on the amount of energy harvested at the sensing location and the type of the sensor. The Kalman filter is used to efficiently obtain the MMSE estimator at the fusion center. Sensors are selected such that the MMSE estimator error is minimized subject to a prescribed system budget. This goal is achieved using convex relaxation and greedy algorithm approaches.

  6. Neutron source strength determination for on-line reactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; Sluijs, A.R. van der

    1988-01-01

    A method is described to determine the effective neutron source strength in a nuclear reactor, which must be known when calculating the time-varying reactivity from inverse reactor kinetics for a reactor at low power. When for an initially subcritical reactor the reactivity is changed and kept constant after the change, the effective source strength can be determined from a linear regression of reactor power to a function proportional to the emission rate of delayed neutrons, which can be calculated from the reactor power history. In view of the relatively strong noise present in the reactor power signal at low power, a grouping method for the regression is preferred over the least-squares method. Experiments with a reactor simulator with known source strength showed good agreement. Application to actual reactor signals gave consistent and satisfactory results.

  7. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  8. Avoiding radiation exposure while training to locate a radioactive source: a virtual reality exercise

    International Nuclear Information System (INIS)

    Marins, E.R.; Cotelli do Espírito Santo, A.; Abreu Mól, A. C. de; Cunha, G.; Landau, L.

    2015-01-01

    A technician undergoing radioprotection training must learn to use radiation detectors. Practical exercises involve being near to radiation sources. The work here presented reduces the exposure to individuals using a virtual environment to achieve preliminary apprenticeship prior using real radioactive sources. (authors)

  9. Efficient Location of Research Reference Sources in the Field of Dance.

    Science.gov (United States)

    Kissinger, Pat; Jay, Danielle

    More than 45 basic dance reference research sources that would be useful to students, scholars, teachers, historians, and therapists are discussed in this bibliographic essay. Aspects of dance covered include choreography, criticism, teaching principles, aesthetic theory, dance therapy, and history. Sources are grouped by type: dictionaries and…

  10. Source contributions to PM2.5 and PM10 at an urban background and a street location

    NARCIS (Netherlands)

    Keuken, M. P.; Moerman, M.; Voogt, M.; Blom, M.; Weijers, E. P.; Rockmann, T.; Dusek, U.

    The contribution of regional, urban and traffic sources to PM2.5 and PM10 in an urban area was investigated in this study. The chemical composition of PM2.5 and PM10 was measured over a year at a street location and up- and down-wind of the city of Rotterdam, the Netherlands. The C-14 content in EC

  11. Source contributions to PM2.5 and PM10 at an urban background and a street location

    NARCIS (Netherlands)

    Keuken, M.P.; Moerman, M.M.; Voogt, M.H.

    2013-01-01

    The contribution of regional, urban and traffic sources to PM2.5 and PM10 in an urban area was investigated in this study. The chemical composition of PM2.5 and PM10 was measured over a year at a street location and up- and down-wind of the city of Rotterdam, the Netherlands. The 14C content in EC

  12. Tree Coring as a Complement to Soil Gas Screening to Locate PCE and TCE Source Zones and Hot Spots

    DEFF Research Database (Denmark)

    Nielsen, Mette Algreen; Trapp, Stefan; Rehne Jensen, Pernille

    2015-01-01

    ) or trichloroethylene (TCE) to evaluate their ability to locate source zones and contaminant hot spots. One test site represented a relatively homogeneous sandy soil and aquifer, and the second a more heterogeneous geology with both sandy and less permeable clay till layers overlying a chalk aquifer. Tree cores from...

  13. Locating sensors for detecting source-to-target patterns of special nuclear material smuggling: a spatial information theoretic approach.

    Science.gov (United States)

    Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong

    2010-01-01

    In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  14. Locating Sensors for Detecting Source-to-Target Patterns of Special Nuclear Material Smuggling: A Spatial Information Theoretic Approach

    Directory of Open Access Journals (Sweden)

    Xuesong Zhou

    2010-08-01

    Full Text Available In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  15. Using web-sources for location based systems on mobile phones

    OpenAIRE

    Pannevis, M.; Marx, M.

    2008-01-01

    The paper describes the implementation of a context aware location and time based system on a normal mobile phone, with a minimum of requirements (Bluetooth, Internet access, Java ME, and a simple webbrowser). We can answer the following queries based on data crawled from the web and enriched with location coordinates: • Where are my friends? • What movies are playing, right here, right now? • I need to park my car. Where is the closest parking lot with free space? • What is a good place to h...

  16. Source term assessment using inverse modeling of radiation dose measured with environmental radiation monitors located at different positions

    International Nuclear Information System (INIS)

    Srinivas, C.V.; Rakesh, P.T.; Baskaran, R.; Venkatraman, B.

    2018-01-01

    Source term is an important input for consequence analysis using Decision Support Systems (DSS) to project radiological impact in the event of nuclear emergencies. A source term model called 'ASTER' is incorporated in the Online Nuclear Emergency Response System (ONERS) operational at Kalpakkam site for decision making during nuclear emergencies. This computes release rates using inverse method by employing an atmospheric dispersion model and gamma dose rates measured by environmental radiation monitors (ERM) deployed around the nuclear plant. The estimates may depend on the distribution of ERMs around the release location. In this work, data from various gamma monitors located at different radii 0.75 km and 1.5 km is used to assess the accuracy in the source term estimation for stack releases of MAPS-PHWR at Kalpakkam

  17. Model for Determining the Optimum Location for Performance Improvement in Supply-Chain Strategies

    Directory of Open Access Journals (Sweden)

    Ramona Iulia ȚARȚAVULEA (DIEACONESCU

    2015-06-01

    Full Text Available The economic crisis which started in 2007 has caused damaging effects to most international companies. In several EU countries, foreign investments decreased and international companies closed or relocated production and/or distribution centres, due to cost reduction measures. This paper is aiming to demonstrate that applying a performant solution in defining the supply chain strategy can be a low cost process, which can generate positive effects on the sales and revenues. The research objective is to present a concrete solution for redesigning the supply chain, in order to achieve the optimal delivery strategy. The solution implies the use of mathematic methods, for determining the optimum location for placing a central warehouse, in a geographic region. The use of an optimum delivery strategy leads to lower depositing and transport costs, which generates positive effects on sales, by offering more competitive prices on products. The main contribution of the author is the development of a model, used to identify the optimal location for placing a central warehouse.

  18. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  19. Location of odor sources and the affected population in Imperial County, California

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, J.L.

    1981-08-01

    This report is divided into four sections. The first two sections contain general background information on Imperial County. The third section is a general discussion of odor sources in Imperial County, and the fourth maps the specific odor sources, the expected areas of perception, and the affected populations. this mapping is done for the Imperial Valley and each of the four Imperial County KGRA's (Known Geothermal Resource Areas) where odor from the development of the geothermal energy may affect population.

  20. Congestion management by determining optimal location of TCSC in deregulated power systems

    International Nuclear Information System (INIS)

    Besharat, Hadi; Taher, Seyed Abbas

    2008-01-01

    In a deregulated electricity market, it may always not be possible to dispatch all of the contracted power transactions due to congestion of the transmission corridors. The ongoing power system restructuring requires an opening of unused potentials of transmission system due to environmental, right-of-way and cost problems which are major hurdles for power transmission network expansion. Flexible AC transmission systems (FACTSs) devices can be an alternative to reduce the flows in heavily loaded lines, resulting in an increased loadability, low system loss, improved stability of the network, reduced cost of production and fulfilled contractual requirement by controlling the power flows in the network. A method to determine the optimal location of thyristor controlled series compensators (TCSCs) has been suggested in this paper based on real power performance index and reduction of total system VAR power losses. (author)

  1. Application of source-receptor models to determine source areas of biological components (pollen and butterflies)

    OpenAIRE

    M. Alarcón; M. Àvila; J. Belmonte; C. Stefanescu; R. Izquierdo

    2010-01-01

    The source-receptor models allow the establishment of relationships between a receptor point (sampling point) and the probable source areas (regions of emission) through the association of concentration values at the receptor point with the corresponding atmospheric back-trajectories, and, together with other techniques, to interpret transport phenomena on a synoptic scale. These models are generally used in air pollution studies to determine the areas of origin of chemical compounds measured...

  2. Using web-sources for location based systems on mobile phones

    NARCIS (Netherlands)

    Pannevis, M.; Marx, M.

    2008-01-01

    The paper describes the implementation of a context aware location and time based system on a normal mobile phone, with a minimum of requirements (Bluetooth, Internet access, Java ME, and a simple webbrowser). We can answer the following queries based on data crawled from the web and enriched with

  3. Application Research of Horn Array Multi-Beam Antenna in Reference Source System for Satellite Interference Location

    Science.gov (United States)

    Zhou, Ping; Lin, Hui; Zhang, Qi

    2018-01-01

    The reference source system is a key factor to ensure the successful location of the satellite interference source. Currently, the traditional system used a mechanical rotating antenna which leaded to the disadvantages of slow rotation and high failure-rate, which seriously restricted the system’s positioning-timeliness and became its obvious weaknesses. In this paper, a multi-beam antenna scheme based on the horn array was proposed as a reference source for the satellite interference location, which was used as an alternative to the traditional reference source antenna. The new scheme has designed a small circularly polarized horn antenna as an element and proposed a multi-beamforming algorithm based on planar array. Moreover, the simulation analysis of horn antenna pattern, multi-beam forming algorithm and simulated satellite link cross-ambiguity calculation have been carried out respectively. Finally, cross-ambiguity calculation of the traditional reference source system has also been tested. The comparison between the results of computer simulation and the actual test results shows that the scheme is scientific and feasible, obviously superior to the traditional reference source system.

  4. A PROCEDURE FOR DETERMINING OPTIMAL FACILITY LOCATION AND SUB-OPTIMAL POSITIONS

    Directory of Open Access Journals (Sweden)

    P.K. Dan

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: This research presents a methodology for determining the optimal location of a new facility, having physical flow interaction of various degrees with other existing facilities in the presence of barriers impeding the shortest flow-path as well as the sub-optimal iso-cost positions. It also determines sub-optimal iso-cost positions with additional cost or penalty for not being able to site it at the computed optimal point. The proposed methodology considers all types of quadrilateral barrier or forbidden region configurations to generalize and by-pass such impenetrable obstacles, and adopts a scheme of searching through the vertices of the quadrilaterals to determine the alternative shortest flow-path. This procedure of obstacle avoidance is novel. Software has been developed to facilitate computations for the search algorithm to determine the optimal and iso-cost co-ordinates. The test results are presented.

    AFRIKAANSE OPSOMMING: Die navorsing behandel ‘n procedure vir die bepaling van optimum stigtingsposisie vir ‘n onderneming met vloei vanaf ander bestaande fasiliteite in die teenwoordigheid van ‘n verskeidenheid van randvoorwaardes. Die prodedure lewer as resultaat suboptimale isokoste-stigtingsplekke met bekendmaking van die koste wat onstaan a.g.v. afwyking van die randvoorwaardlose optimum oplossingskoste, die prosedure maak gebruik van ‘n vindingryke soekmetode wat toegepas word op niersydige meerkundige voorstellings vir die bepaling van korste roetes wat versperring omseil. Die prosedure word onderskei deur programmatuur. Toetsresultate word voorgehou.

  5. Determination of source term for Krsko NPP extended fuel cycle

    International Nuclear Information System (INIS)

    Nemec, T.; Persic, A.; Zagar, T.; Zefran, B.

    2004-01-01

    The activity and composition of the potential radioactive releases (source term) is important in the decision making about off-site emergency measures in case of a release into environment. Power uprate of Krsko NPP during modernization in 2000 as well as changing of the fuel type and the core design have influenced the source term value. In 2003 a project of 'Jozef Stefan' Institute and Slovenian nuclear safety administration determined a plantspecific source term for new conditions of fuel type and burnup for extended fuel cycle. Calculations of activity and isotopic composition of the core have been performed with ORIGEN-ARP program. Results showed that the core activity for extended 15 months fuel cycle is slightly lower than for the 12 months cycles, mainly due to larger share of fresh fuel. (author)

  6. The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration.

    Science.gov (United States)

    Kim, Yong Chan; Jung, Younhea; Park, Hae-Young Lopilly; Park, Chan Kee

    2017-07-19

    Tilted and rotated appearances are hallmarks of the myopic optic disc. As the eyeball grows axially, the posterior pole elongates not only globally but in a localized manner as well. In this process, the optic disc is pulled towards the deepest point of the elongated eyeball, which might result in a change in optic disc configuration. Thus, we hypothesized that analyzing the variation of posterior pole contour can play a major role in understanding optic disc configuration in myopic subjects. By analyzing consecutive images of swept source OCT coronal sections at the posterior pole, the deepest interface between Bruch's membrane and the choroid could be identified as the deepest point of the eyeball (DPE). The location and the properties of the DPE differed significantly between the 125 eyes of non-glaucomatous myopic group and the 40 eyes of non-glaucomatous emmetropic group classified based on 24 mm axial length. The results suggested that the larger disc to DPE angle and the larger disc to DPE depth strongly predicts the optic disc torsion degree and the optic disc tilt. Our findings suggest that identifying the posterior pole profile plays a major role in understanding the optic disc alterations found in myopic subjects.

  7. Source location in plates based on the multiple sensors array method and wavelet analysis

    International Nuclear Information System (INIS)

    Yang, Hong Jun; Shin, Tae Jin; Lee, Sang Kwon

    2014-01-01

    A new method for impact source localization in a plate is proposed based on the multiple signal classification (MUSIC) and wavelet analysis. For source localization, the direction of arrival of the wave caused by an impact on a plate and the distance between impact position and sensor should be estimated. The direction of arrival can be estimated accurately using MUSIC method. The distance can be obtained by using the time delay of arrival and the group velocity of the Lamb wave in a plate. Time delay is experimentally estimated using the continuous wavelet transform for the wave. The elasto dynamic theory is used for the group velocity estimation.

  8. Source location in plates based on the multiple sensors array method and wavelet analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hong Jun; Shin, Tae Jin; Lee, Sang Kwon [Inha University, Incheon (Korea, Republic of)

    2014-01-15

    A new method for impact source localization in a plate is proposed based on the multiple signal classification (MUSIC) and wavelet analysis. For source localization, the direction of arrival of the wave caused by an impact on a plate and the distance between impact position and sensor should be estimated. The direction of arrival can be estimated accurately using MUSIC method. The distance can be obtained by using the time delay of arrival and the group velocity of the Lamb wave in a plate. Time delay is experimentally estimated using the continuous wavelet transform for the wave. The elasto dynamic theory is used for the group velocity estimation.

  9. Influence of Sound Source Location on the Behavior and Physiology of the Precedence Effect in Cats

    OpenAIRE

    Dent, Micheal L.; Tollin, Daniel J.; Yin, Tom C. T.

    2009-01-01

    Psychophysical experiments on the precedence effect (PE) in cats have shown that they localize pairs of auditory stimuli presented from different locations in space based on the spatial position of the stimuli and the interstimulus delay (ISD) between the stimuli in a manner similar to humans. Cats exhibit localization dominance for pairs of transient stimuli with |ISDs| from ∼0.4 to 10 ms, summing localization for |ISDs| 10 ms, which is the appro...

  10. Fast 3D elastic micro-seismic source location using new GPU features

    Science.gov (United States)

    Xue, Qingfeng; Wang, Yibo; Chang, Xu

    2016-12-01

    In this paper, we describe new GPU features and their applications in passive seismic - micro-seismic location. Locating micro-seismic events is quite important in seismic exploration, especially when searching for unconventional oil and gas resources. Different from the traditional ray-based methods, the wave equation method, such as the method we use in our paper, has a remarkable advantage in adapting to low signal-to-noise ratio conditions and does not need a person to select the data. However, because it has a conspicuous deficiency due to its computation cost, these methods are not widely used in industrial fields. To make the method useful, we implement imaging-like wave equation micro-seismic location in a 3D elastic media and use GPU to accelerate our algorithm. We also introduce some new GPU features into the implementation to solve the data transfer and GPU utilization problems. Numerical and field data experiments show that our method can achieve a more than 30% performance improvement in GPU implementation just by using these new features.

  11. Application of the PROMETHEE technique to determine depression outlet location and flow direction in DEM

    Science.gov (United States)

    Chou, Tien-Yin; Lin, Wen-Tzu; Lin, Chao-Yuan; Chou, Wen-Chieh; Huang, Pi-Hui

    2004-02-01

    With the fast growing progress of computer technologies, spatial information on watersheds such as flow direction, watershed boundaries and the drainage network can be automatically calculated or extracted from a digital elevation model (DEM). The stubborn problem that depressions exist in DEMs has been frequently encountered while extracting the spatial information of terrain. Several filling-up methods have been proposed for solving depressions. However, their suitability for large-scale flat areas is inadequate. This study proposes a depression watershed method coupled with the Preference Ranking Organization METHod for Enrichment Evaluations (PROMETHEEs) theory to determine the optimal outlet and calculate the flow direction in depressions. Three processing procedures are used to derive the depressionless flow direction: (1) calculating the incipient flow direction; (2) establishing the depression watershed by tracing the upstream drainage area and determining the depression outlet using PROMETHEE theory; (3) calculating the depressionless flow direction. The developed method was used to delineate the Shihmen Reservoir watershed located in Northern Taiwan. The results show that the depression watershed method can effectively solve the shortcomings such as depression outlet differentiating and looped flow direction between depressions. The suitability of the proposed approach was verified.

  12. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  13. A New Wave Equation Based Source Location Method with Full-waveform Inversion

    KAUST Repository

    Wu, Zedong; Alkhalifah, Tariq Ali

    2017-01-01

    with illumination artifacts. We develop a waveform inversion approach with an additional penalty term in the objective function to reward the focusing of the source image. This penalty term is relaxed early to allow for data fitting, and avoid cycle skipping, using

  14. Impacts of Reverberation Time, Absorption Location and Background Noise on Listening Conditions in Multi Source Environment

    DEFF Research Database (Denmark)

    Saher, Konca; Rindel, Jens Holger; Nijs, Lau

    2005-01-01

    index (STI) needs to be improved. The impact of the reverberation time (RT), the distribution of the absorptive materials and the introduction of a screen on STI are discussed briefly .However, these objective parameters have to be assessed through subjective judgement. Auralizations of the multi source...

  15. Locating People Diagnosed With HIV for Public Health Action: Utility of HIV Case Surveillance and Other Data Sources.

    Science.gov (United States)

    Padilla, Mabel; Mattson, Christine L; Scheer, Susan; Udeagu, Chi-Chi N; Buskin, Susan E; Hughes, Alison J; Jaenicke, Thomas; Wohl, Amy Rock; Prejean, Joseph; Wei, Stanley C

    Human immunodeficiency virus (HIV) case surveillance and other health care databases are increasingly being used for public health action, which has the potential to optimize the health outcomes of people living with HIV (PLWH). However, often PLWH cannot be located based on the contact information available in these data sources. We assessed the accuracy of contact information for PLWH in HIV case surveillance and additional data sources and whether time since diagnosis was associated with accurate contact information in HIV case surveillance and successful contact. The Case Surveillance-Based Sampling (CSBS) project was a pilot HIV surveillance system that selected a random population-based sample of people diagnosed with HIV from HIV case surveillance registries in 5 state and metropolitan areas. From November 2012 through June 2014, CSBS staff members attempted to locate and interview 1800 sampled people and used 22 data sources to search for contact information. Among 1063 contacted PLWH, HIV case surveillance data provided accurate telephone number, address, or HIV care facility information for 239 (22%), 412 (39%), and 827 (78%) sampled people, respectively. CSBS staff members used additional data sources, such as support services and commercial people-search databases, to locate and contact PLWH with insufficient contact information in HIV case surveillance. PLWH diagnosed surveillance than were PLWH diagnosed ≥1 year ago ( P = .002), and the benefit from using additional data sources was greater for PLWH with more longstanding HIV infection ( P surveillance cannot provide accurate contact information, health departments can prioritize searching additional data sources, especially for people with more longstanding HIV infection.

  16. Crowd-Sourced Mobility Mapping for Location Tracking Using Unlabeled Wi-Fi Simultaneous Localization and Mapping

    Directory of Open Access Journals (Sweden)

    Mu Zhou

    2015-01-01

    Full Text Available Due to the increasing requirements of the seamless and round-the-clock Location-based services (LBSs, a growing interest in Wi-Fi network aided location tracking is witnessed in the past decade. One of the significant problems of the conventional Wi-Fi location tracking approaches based on received signal strength (RSS fingerprinting is the time-consuming and labor intensive work involved in location fingerprint calibration. To solve this problem, a novel unlabeled Wi-Fi simultaneous localization and mapping (SLAM approach is developed to avoid the location fingerprinting and additional inertial or vision sensors. In this approach, an unlabeled mobility map of the coverage area is first constructed by using the crowd-sourcing from a batch of sporadically recorded Wi-Fi RSS sequences based on the spectral cluster assembling. Then, the sequence alignment algorithm is applied to conduct location tracking and mobility map updating. Finally, the effectiveness of this approach is verified by the extensive experiments carried out in a campus-wide area.

  17. Military Service Records and Unit Histories: A Guide to Locating Sources

    Science.gov (United States)

    2012-07-26

    records, therefoa- e , written authorization from the veta -an or ne.’Ct of kin is not rEqUired. However, in ordet" to protect the privacy of the...line E -mail: MPR.center@nara.gov Older military personnel records (generally prior to World War I, depending on the service branch) are located at...AFB, DC 20032-5000 E -mail: afhso.research@pentagon.af.mil http://www.afhso.af.mil/ (202) 404-2264 National Museum of the U.S. Air Force 1100

  18. A rotating modulation imager for locating mid-range point sources

    International Nuclear Information System (INIS)

    Kowash, B.R.; Wehe, D.K.; Fessler, J.A.

    2009-01-01

    Rotating modulation collimators (RMC) are relatively simple indirect imaging devices that have proven useful in gamma ray astronomy (far field) and have more recently been studied for medical imaging (very near field). At the University of Michigan a RMC has been built to study the performance for homeland security applications. This research highlights the imaging performance of this system and focuses on three distinct regions in the RMC field of view that can impact the search for hidden sources. These regions are a blind zone around the axis of rotation, a two mask image zone that extends from the blind zone to the edge of the field of view, and a single mask image zone that occurs when sources fall outside the field of view of both masks. By considering the extent and impact of these zones, the size of the two mask region can be optimized for the best system performance.

  19. Locating the Tohoku-Oki 2011 tsunami source using acoustic-gravity waves

    OpenAIRE

    Andriamiranto Raveloson; Rainer Kind; Xiaohui Yuan; L. Cerana

    2012-01-01

    The giant Tohoku-Oki earthquake of 11 March 2011 in offshore Japan did not only generate tsunami waves in the ocean but also infrasound (or acoustic-gravity) waves in the atmosphere. We indentified ultra-long-period signals (>500s) in the recordings of infrasound stations in northeast Asia, the northwest Pacific, and Alaska. Their source was fond close to the earthquake epicenter. Therefore, we conclude that in general, infrasound observations after a large offshore earthquake are evidence th...

  20. Source Apportionment of Particle Bound Polycyclic Aromatic Hydrocarbons at an Industrial Location in Agra, India

    Directory of Open Access Journals (Sweden)

    Anita Lakhani

    2012-01-01

    Full Text Available 16 US EPA priority polycyclic aromatic hydrocarbons (PAHs were quantified in total suspended ambient particulate matter (TSPM collected from an industrial site in Agra (India using gas chromatography. The major industrial activities in Agra are foundries that previously used coal and coke as fuel in cupola furnaces. These foundries have now switched over to natural gas. In addition, use of compressed natural gas has also been promoted and encouraged in automobiles. This study attempts to apportion sources of PAH in the ambient air and the results reflect the advantages associated with the change of fuel. The predominant PAHs in TSPM include high molecular weight (HMW congeners BghiP, DbA, IP, and BaP. The sum of 16 priority PAHs had a mean value of 72.7 ± 4.7 ng m−3. Potential sources of PAHs in aerosols were identified using diagnostic ratios and principal component analysis. The results reflect a blend of emissions from diesel and natural gas as the major sources of PAH in the city along with contribution from emission of coal, coke, and gasoline.

  1. Sources of Caffeine in Diets of US Children and Adults: Trends by Beverage Type and Purchase Location

    OpenAIRE

    Adam Drewnowski; Colin D. Rehm

    2016-01-01

    New sources of caffeine, besides coffee and tea, have been introduced into the US food supply. Data on caffeine consumption age and purchase location can help guide public health policy. National Health and Nutrition Examination Surveys (NHANES) were used to estimate population-level caffeine intakes, using data from 24-h dietary recall. First, caffeine intakes by age-group and beverage type were estimated using the most recent 2011?2012 data (n = 7456). Second, fourteen years trends in caffe...

  2. Automated Determination of Magnitude and Source Length of Large Earthquakes

    Science.gov (United States)

    Wang, D.; Kawakatsu, H.; Zhuang, J.; Mori, J. J.; Maeda, T.; Tsuruoka, H.; Zhao, X.

    2017-12-01

    Rapid determination of earthquake magnitude is of importance for estimating shaking damages, and tsunami hazards. However, due to the complexity of source process, accurately estimating magnitude for great earthquakes in minutes after origin time is still a challenge. Mw is an accurate estimate for large earthquakes. However, calculating Mw requires the whole wave trains including P, S, and surface phases, which takes tens of minutes to reach stations at tele-seismic distances. To speed up the calculation, methods using W phase and body wave are developed for fast estimating earthquake sizes. Besides these methods that involve Green's Functions and inversions, there are other approaches that use empirically simulated relations to estimate earthquake magnitudes, usually for large earthquakes. The nature of simple implementation and straightforward calculation made these approaches widely applied at many institutions such as the Pacific Tsunami Warning Center, the Japan Meteorological Agency, and the USGS. Here we developed an approach that was originated from Hara [2007], estimating magnitude by considering P-wave displacement and source duration. We introduced a back-projection technique [Wang et al., 2016] instead to estimate source duration using array data from a high-sensitive seismograph network (Hi-net). The introduction of back-projection improves the method in two ways. Firstly, the source duration could be accurately determined by seismic array. Secondly, the results can be more rapidly calculated, and data derived from farther stations are not required. We purpose to develop an automated system for determining fast and reliable source information of large shallow seismic events based on real time data of a dense regional array and global data, for earthquakes that occur at distance of roughly 30°- 85° from the array center. This system can offer fast and robust estimates of magnitudes and rupture extensions of large earthquakes in 6 to 13 min (plus

  3. Method to determine the strength of a neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Chacon R, A.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Depto. Ingenieria Nuclear, Universidad Politecnica de Madrid, (Spain)

    2006-07-01

    The use of a gamma-ray spectrometer with a 3 {phi} x 3 NaI(Tl) detector, with a moderator sphere has been studied in the aim to measure the neutron fluence rate and to determine the source strength. Moderators with a large amount of hydrogen are able to slowdown and thermalize neutrons; once thermalized there is a probability that thermal neutron to be captured by hydrogen producing 2.22 MeV prompt gamma-ray. The pulse-height spectrum collected in a multicharmel analyzer shows a photopeak around 2.22 MeV whose net area is proportional to total neutron fluence rate and to the neutron source strength. The characteristics of this system were determined by a Monte Carlo study using the MCNP 4C code, where a detailed model of the Nal(Tl) was utilized. As moderators 3, 5, and 10 inches-diameter spheres where utilized and the response was calculated for monoenergetic and isotopic neutrons sources. (Author)

  4. Source locations for impulsive electric signals seen in the night ionosphere of Venus

    Science.gov (United States)

    Russell, C. T.; Von Dornum, M.; Scarf, F. L.

    1989-01-01

    A mapping of the rate of occurrence of impulsive VLF noise bursts in Venus' dark low altitude ionosphere, which increases rapidly with decreasing altitude, as a function of latitude and longitude indicates enhanced occurrence rates over Atla. In a 30-sec observing period, there are impulsive signals 70 percent of the time at 160 km in the region of maximum occurrence; the occurrence rates, moreover, increase with decreasing latitude, so that the equatorial rate is of the order of 1.6 times that at 30 deg latitude. These phenomena are in keeping with lightning-generated wave sources.

  5. Radar Determination of Fault Slip and Location in Partially Decorrelated Images

    Science.gov (United States)

    Parker, Jay; Glasscoe, Margaret; Donnellan, Andrea; Stough, Timothy; Pierce, Marlon; Wang, Jun

    2017-06-01

    Faced with the challenge of thousands of frames of radar interferometric images, automated feature extraction promises to spur data understanding and highlight geophysically active land regions for further study. We have developed techniques for automatically determining surface fault slip and location using deformation images from the NASA Uninhabited Aerial Vehicle Synthetic Aperture Radar (UAVSAR), which is similar to satellite-based SAR but has more mission flexibility and higher resolution (pixels are approximately 7 m). This radar interferometry provides a highly sensitive method, clearly indicating faults slipping at levels of 10 mm or less. But interferometric images are subject to decorrelation between revisit times, creating spots of bad data in the image. Our method begins with freely available data products from the UAVSAR mission, chiefly unwrapped interferograms, coherence images, and flight metadata. The computer vision techniques we use assume no data gaps or holes; so a preliminary step detects and removes spots of bad data and fills these holes by interpolation and blurring. Detected and partially validated surface fractures from earthquake main shocks, aftershocks, and aseismic-induced slip are shown for faults in California, including El Mayor-Cucapah (M7.2, 2010), the Ocotillo aftershock (M5.7, 2010), and South Napa (M6.0, 2014). Aseismic slip is detected on the San Andreas Fault from the El Mayor-Cucapah earthquake, in regions of highly patterned partial decorrelation. Validation is performed by comparing slip estimates from two interferograms with published ground truth measurements.

  6. Waveform inversion of lateral velocity variation from wavefield source location perturbation

    KAUST Repository

    Choi, Yun Seok

    2013-09-22

    It is challenge in waveform inversion to precisely define the deep part of the velocity model compared to the shallow part. The lateral velocity variation, or what referred to as the derivative of velocity with respect to the horizontal distance, with well log data can be used to update the deep part of the velocity model more precisely. We develop a waveform inversion algorithm to obtain the lateral velocity variation by inverting the wavefield variation associated with the lateral shot location perturbation. The gradient of the new waveform inversion algorithm is obtained by the adjoint-state method. Our inversion algorithm focuses on resolving the lateral changes of the velocity model with respect to a fixed reference vertical velocity profile given by a well log. We apply the method on a simple-dome model to highlight the methods potential.

  7. Metamaterials-based sensor to detect and locate nonlinear elastic sources

    Energy Technology Data Exchange (ETDEWEB)

    Gliozzi, Antonio S.; Scalerandi, Marco [Department of Applied Science and Technology, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Miniaci, Marco; Bosia, Federico [Department of Physics, University of Torino, Via Pietro Giuria 1, 10125 Torino (Italy); Pugno, Nicola M. [Laboratory of Bio-Inspired and Graphene Nanomechanics, Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano 77, 38123 Trento (Italy); Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo (Trento) (Italy); School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom)

    2015-10-19

    In recent years, acoustic metamaterials have attracted increasing scientific interest for very diverse technological applications ranging from sound abatement to ultrasonic imaging, mainly due to their ability to act as band-stop filters. At the same time, the concept of chaotic cavities has been recently proposed as an efficient tool to enhance the quality of nonlinear signal analysis, particularly in the ultrasonic/acoustic case. The goal of the present paper is to merge the two concepts in order to propose a metamaterial-based device that can be used as a natural and selective linear filter for the detection of signals resulting from the propagation of elastic waves in nonlinear materials, e.g., in the presence of damage, and as a detector for the damage itself in time reversal experiments. Numerical simulations demonstrate the feasibility of the approach and the potential of the device in providing improved signal-to-noise ratios and enhanced focusing on the defect locations.

  8. Metamaterials-based sensor to detect and locate nonlinear elastic sources

    International Nuclear Information System (INIS)

    Gliozzi, Antonio S.; Scalerandi, Marco; Miniaci, Marco; Bosia, Federico; Pugno, Nicola M.

    2015-01-01

    In recent years, acoustic metamaterials have attracted increasing scientific interest for very diverse technological applications ranging from sound abatement to ultrasonic imaging, mainly due to their ability to act as band-stop filters. At the same time, the concept of chaotic cavities has been recently proposed as an efficient tool to enhance the quality of nonlinear signal analysis, particularly in the ultrasonic/acoustic case. The goal of the present paper is to merge the two concepts in order to propose a metamaterial-based device that can be used as a natural and selective linear filter for the detection of signals resulting from the propagation of elastic waves in nonlinear materials, e.g., in the presence of damage, and as a detector for the damage itself in time reversal experiments. Numerical simulations demonstrate the feasibility of the approach and the potential of the device in providing improved signal-to-noise ratios and enhanced focusing on the defect locations

  9. Toward morphological thoracic EIT: major signal sources correspond to respective organ locations in CT.

    Science.gov (United States)

    Ferrario, Damien; Grychtol, Bartłomiej; Adler, Andy; Solà, Josep; Böhm, Stephan H; Bodenstein, Marc

    2012-11-01

    Lung and cardiovascular monitoring applications of electrical impedance tomography (EIT) require localization of relevant functional structures or organs of interest within the reconstructed images. We describe an algorithm for automatic detection of heart and lung regions in a time series of EIT images. Using EIT reconstruction based on anatomical models, candidate regions are identified in the frequency domain and image-based classification techniques applied. The algorithm was validated on a set of simultaneously recorded EIT and CT data in pigs. In all cases, identified regions in EIT images corresponded to those manually segmented in the matched CT image. Results demonstrate the ability of EIT technology to reconstruct relevant impedance changes at their anatomical locations, provided that information about the thoracic boundary shape (and electrode positions) are used for reconstruction.

  10. Seasonal Differences in Determinants of Time Location Patterns in an Urban Population: A Large Population-Based Study in Korea.

    Science.gov (United States)

    Lee, Sewon; Lee, Kiyoung

    2017-06-22

    Time location patterns are a significant factor for exposure assessment models of air pollutants. Factors associated with time location patterns in urban populations are typically due to high air pollution levels in urban areas. The objective of this study was to determine the seasonal differences in time location patterns in two urban cities. A Time Use Survey of Korean Statistics (KOSTAT) was conducted in the summer, fall, and winter of 2014. Time location data from Seoul and Busan were collected, together with demographic information obtained by diaries and questionnaires. Determinants of the time spent at each location were analyzed by multiple linear regression and the stepwise method. Seoul and Busan participants had similar time location profiles over the three seasons. The time spent at own home, other locations, workplace/school and during walk were similar over the three seasons in both the Seoul and Busan participants. The most significant time location pattern factors were employment status, age, gender, monthly income, and spouse. Season affected the time spent at the workplace/school and other locations in the Seoul participants, but not in the Busan participants. The seasons affected each time location pattern of the urban population slightly differently, but overall there were few differences.

  11. Seasonal Differences in Determinants of Time Location Patterns in an Urban Population: A Large Population-Based Study in Korea

    Directory of Open Access Journals (Sweden)

    Sewon Lee

    2017-06-01

    Full Text Available Time location patterns are a significant factor for exposure assessment models of air pollutants. Factors associated with time location patterns in urban populations are typically due to high air pollution levels in urban areas. The objective of this study was to determine the seasonal differences in time location patterns in two urban cities. A Time Use Survey of Korean Statistics (KOSTAT was conducted in the summer, fall, and winter of 2014. Time location data from Seoul and Busan were collected, together with demographic information obtained by diaries and questionnaires. Determinants of the time spent at each location were analyzed by multiple linear regression and the stepwise method. Seoul and Busan participants had similar time location profiles over the three seasons. The time spent at own home, other locations, workplace/school and during walk were similar over the three seasons in both the Seoul and Busan participants. The most significant time location pattern factors were employment status, age, gender, monthly income, and spouse. Season affected the time spent at the workplace/school and other locations in the Seoul participants, but not in the Busan participants. The seasons affected each time location pattern of the urban population slightly differently, but overall there were few differences.

  12. Determination of heavy metals in the fruit of date palm growing at different locations of Riyadh.

    Science.gov (United States)

    Aldjain, Ibrahim M; Al-Whaibi, Mohamed H; Al-Showiman, Salim S; Siddiqui, Manzer H

    2011-04-01

    Exposure of heavy metals to human beings has risen dramatically in the last 50 years. In today's urban and industrial society, there is no escaping from exposure to toxic chemicals and heavy metals. Humans are more likely to be exposed to heavy metal contamination from the dust that adheres to edible plants than from bioaccumulation. This is because it is very difficult to wash off all the dust particles from the plant material before ingesting them. The objectives of this experiment were to determine the concentrations of lead (Pb) and cadmium (Cd) in washing residues and in the tissues of fruits of date palm growing in 14 sites of Riyadh and also to assess whether the fruits were safe for human consumption. The washing residues and tissue of date palm fruits collected from different sites showed the presence of significant amounts of the Pb and Cd. The concentration of Pb in the dust and fruit tissue increased with increasing anthropogenic sources. Therefore, fruits of date palm might be used as a pollution indicator; it might be recommend that fruits of date palm could be safe for human consumption after washing. The mean concentration of Pb and Cd in all the samples collected from different sites is within the safe limits recommended by FAO/WHO.

  13. The determination of neutron energy spectra of radioisotope sources

    International Nuclear Information System (INIS)

    Lutkin, J.E.

    1975-08-01

    The neutron energy spectrum of a 241 Am-Be radioisotope neutron source has been determined by use of a time of flight neutron spectrometer; this spectrometer not being subject to the same uncertainties as a scintillation spectrometer. Neutron spectra have been determined using a scintillation spectrometer with which the effects of instrumental uncertainties, particularly the pulse shape discrimination have been assessed. In the course of the development of the time flight spectrometer a zero crossover pulse shape discrimination system was developed in order to reduce the unwanted background. Using this system a quantitative survey of pulse shape discrimination with experimental and commercial liquid and plastic organic scintillators were carried out. In addition the pulse shape discrimination properties of inorganic scintillators were also examined. (author)

  14. Seismic swarm associated with the 2008 eruption of Kasatochi Volcano, Alaska: earthquake locations and source parameters

    Science.gov (United States)

    Ruppert, Natalia G.; Prejean, Stephanie G.; Hansen, Roger A.

    2011-01-01

    An energetic seismic swarm accompanied an eruption of Kasatochi Volcano in the central Aleutian volcanic arc in August of 2008. In retrospect, the first earthquakes in the swarm were detected about 1 month prior to the eruption onset. Activity in the swarm quickly intensified less than 48 h prior to the first large explosion and subsequently subsided with decline of eruptive activity. The largest earthquake measured as moment magnitude 5.8, and a dozen additional earthquakes were larger than magnitude 4. The swarm exhibited both tectonic and volcanic characteristics. Its shear failure earthquake features were b value = 0.9, most earthquakes with impulsive P and S arrivals and higher-frequency content, and earthquake faulting parameters consistent with regional tectonic stresses. Its volcanic or fluid-influenced seismicity features were volcanic tremor, large CLVD components in moment tensor solutions, and increasing magnitudes with time. Earthquake location tests suggest that the earthquakes occurred in a distributed volume elongated in the NS direction either directly under the volcano or within 5-10 km south of it. Following the MW 5.8 event, earthquakes occurred in a new crustal volume slightly east and north of the previous earthquakes. The central Aleutian Arc is a tectonically active region with seismicity occurring in the crusts of the Pacific and North American plates in addition to interplate events. We postulate that the Kasatochi seismic swarm was a manifestation of the complex interaction of tectonic and magmatic processes in the Earth's crust. Although magmatic intrusion triggered the earthquakes in the swarm, the earthquakes failed in context of the regional stress field.

  15. Use of Loran-C navigation system to accurately determine sampling site location in an above ground cooling reservoir

    International Nuclear Information System (INIS)

    Lockwood, R.E.; Blankinship, D.R.

    1994-01-01

    Environmental monitoring programs often require accurate determination of sampling site locations in aquatic environments. This is especially true when a open-quotes pictureclose quotes of high resolution is needed for observing a changing variable in a given area and location is assumed to be important to the distribution of that variable. Sample site location can be difficult if few visible land marks are available for reference on a large body of water. The use of navigational systems such as Global Positioning System (GPS) and its predecessor, Loran-C, provide an excellent method for sample site location. McFarland (1992) discusses the practicality of GPS for location determination. This article discusses the use of Loran-C in a sampling scheme implemented at the South Texas Project Electrical Generating Station (STPEGS), Wadsworth, Texas

  16. Characterizing and locating air pollution sources in a complex industrial district using optical remote sensing technology and multivariate statistical modeling.

    Science.gov (United States)

    Chang, Pao-Erh Paul; Yang, Jen-Chih Rena; Den, Walter; Wu, Chang-Fu

    2014-09-01

    Emissions of volatile organic compounds (VOCs) are most frequent environmental nuisance complaints in urban areas, especially where industrial districts are nearby. Unfortunately, identifying the responsible emission sources of VOCs is essentially a difficult task. In this study, we proposed a dynamic approach to gradually confine the location of potential VOC emission sources in an industrial complex, by combining multi-path open-path Fourier transform infrared spectrometry (OP-FTIR) measurement and the statistical method of principal component analysis (PCA). Close-cell FTIR was further used to verify the VOC emission source by measuring emitted VOCs from selected exhaust stacks at factories in the confined areas. Multiple open-path monitoring lines were deployed during a 3-month monitoring campaign in a complex industrial district. The emission patterns were identified and locations of emissions were confined by the wind data collected simultaneously. N,N-Dimethyl formamide (DMF), 2-butanone, toluene, and ethyl acetate with mean concentrations of 80.0 ± 1.8, 34.5 ± 0.8, 103.7 ± 2.8, and 26.6 ± 0.7 ppbv, respectively, were identified as the major VOC mixture at all times of the day around the receptor site. As the toxic air pollutant, the concentrations of DMF in air samples were found exceeding the ambient standard despite the path-average effect of OP-FTIR upon concentration levels. The PCA data identified three major emission sources, including PU coating, chemical packaging, and lithographic printing industries. Applying instrumental measurement and statistical modeling, this study has established a systematic approach for locating emission sources. Statistical modeling (PCA) plays an important role in reducing dimensionality of a large measured dataset and identifying underlying emission sources. Instrumental measurement, however, helps verify the outcomes of the statistical modeling. The field study has demonstrated the feasibility of

  17. Plasma assisted growth of MoO{sub 3} films on different substrate locations relative to sublimation source

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Rabindar K., E-mail: rkrksharma6@gmail.com; Saini, Sujit K.; Kumar, Prabhat; Singh, Megha; Reddy, G. B. [Thin film laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi – 110016 (India)

    2016-05-06

    In the present paper, we reported the role of substrate locations relative to source on the growth of MoO{sub 3} films deposited on Ni coated glass substrates using plasma assisted sublimation process (PASP). According to the XRD and SEM results, substrate location is very crucial factor to control the morphology of MoO{sub 3} films and the best nanostructure growth (in terms of alignments and features) is obtained in case of Sample B (in which substrate is placed on source). The structural results point out that all films exhibit only orthorhombic phase of molybdenum oxide (i.e. α-MoO{sub 3})but the most preferential growth is recorded in Sample B due to the presence of intense peaks crossponding to only (0 k 0) family of crystal planes (k = 2, 4,6..). The Raman analysis again confirms the orthorhombic nature of MoO{sub 3} NFs and details of vibrational bondsin Sample B have been given in the present report. The MoO{sub 3} NFs show intense PL emission in wavelength range of 300-700 nm with three peaks located at 415, 490, and 523 nm in accordance to the improved crystallinity in Sample B.

  18. Fuel from Wastewater - Harnessing a Potential Energy Source in Canada through the Co-location of Algae Biofuel Production to Sources of Effluent, Heat and CO2

    Science.gov (United States)

    Klise, G. T.; Roach, J. D.; Passell, H. D.; Moreland, B. D.; O'Leary, S. J.; Pienkos, P. T.; Whalen, J.

    2010-12-01

    Sandia National Laboratories is collaborating with the National Research Council (NRC) Canada and the National Renewable Energy Laboratory (NREL) to develop a decision-support model that will evaluate the tradeoffs associated with high-latitude algae biofuel production co-located with wastewater, CO2, and waste heat. This project helps Canada meet its goal of diversifying fuel sources with algae-based biofuels. The biofuel production will provide a wide range of benefits including wastewater treatment, CO2 reuse and reduction of demand for fossil-based fuels. The higher energy density in algae-based fuels gives them an advantage over crop-based biofuels as the “production” footprint required is much less, resulting in less water consumed and little, if any conversion of agricultural land from food to fuel production. Besides being a potential source for liquid fuel, algae have the potential to be used to generate electricity through the burning of dried biomass, or anaerobically digested to generate methane for electricity production. Co-locating algae production with waste streams may be crucial for making algae an economically valuable fuel source, and will certainly improve its overall ecological sustainability. The modeling process will address these questions, and others that are important to the use of water for energy production: What are the locations where all resources are co-located, and what volumes of algal biomass and oil can be produced there? In locations where co-location does not occur, what resources should be transported, and how far, while maintaining economic viability? This work is being funded through the U.S. Department of Energy (DOE) Biomass Program Office of Energy Efficiency and Renewable Energy, and is part of a larger collaborative effort that includes sampling, strain isolation, strain characterization and cultivation being performed by the NREL and Canada’s NRC. Results from the NREL / NRC collaboration including specific

  19. Determination of the X, Y coordinates of a pulsed ultrasonic source of signals

    International Nuclear Information System (INIS)

    Sokolov, B.V.; Shemyakin, V.V.

    1975-01-01

    A range of problems in predicting the emergency state of large-scale vessel housings are determined for subsequent solution involving acoustic emission phenomena. The authors specify the position of a given problem and present substantial grounds for selecting the minimum number of group signal receivers for unambiguous calculation of the location of the source. Relationships are obtained between X, Y - the coordinates of the pulse signal source - and experimentally measured time differences in recording of signals by group receivers. A criterion is given for selecting the true signal group combination when the receivers simultaneously record waves from several sources. Specific suggestions are made regarding the experimental information to be stored in a central computer for subsequent processing [ru

  20. Ownership characteristics as determinants of FDI location decisions in emerging economies

    OpenAIRE

    Lien, Y-C.; Filatotchev, I.

    2015-01-01

    Building on agency theory and international business research, this paper explores how parent firm and subsidiary ownership factors affect FDI location decisions in emerging economies. Our analysis suggests that ownerships of block-shareholders in the parent firm (i.e., controlling family, non-family TMT members and institutional investors) and equity stake in a subsidiary owned by the parent company are positively associated with FDI location decisions in less-explored and risky areas. Howev...

  1. Development of a method for determining the location of heterogeneous activity present in 200 litre waste drum using USB based MCS system

    International Nuclear Information System (INIS)

    Singh, Sarbjit; Mhatre, Amol; Sagar, Veena; Gupta, Nidhi

    2014-01-01

    A method was developed for determining the location of activity present in 200 litre waste drum using USB based MCS system coupled to a segmented gamma ray scanner. 137 Cs source was kept at various distances from centre of the drum along the axis of the detector. Drum was rotated and the activity profiles were determined as a function of angle of rotation. The plot of the count rate as a function of angle of rotation was found to have two peaks. The experimental and calculated data were found to match well at all angles. Present studies have shown that the ratio of height and width of the profile at angles of 0 ° and 180° can be used to determine the location of the activity in the drum. (author)

  2. Shifting primary energy source and NOx emission location with plug-in hybrid vehicles

    Science.gov (United States)

    Karman, Deniz

    2011-06-01

    Plug-in hybrid vehicles (PHEVs) present an interesting technological opportunity for using non-fossil primary energy in light duty passenger vehicles, with the associated potential for reducing air pollutant and greenhouse gas emissions, to the extent that the electric power grid is fed by non-fossil sources. This perspective, accompanying the article by Thompson et al (2011) in this issue, will touch on two other studies that are directly related: the Argonne study (Elgowainy et al 2010) and a PhD thesis from Utrecht (van Vliet 2010). Thompson et al (2011) have examined air quality effects in a case where the grid is predominantly fossil fed. They estimate a reduction of 7.42 tons/day of NOx from motor vehicles as a result of substituting electric VMTs for 20% of the light duty gasoline vehicle miles traveled. To estimate the impact of this reduction on air quality they also consider the increases in NOx emissions due to the increased load on electricity generating units. The NOx emission increases are estimated as 4.0, 5.5 and 6.3 tons for the Convenience, Battery and Night charging scenarios respectively. The net reductions are thus in the 1.1-3.4 tons/day range. The air quality modelling results presented show that the air quality impact from a ground-level ozone perspective is favorable overall, and while the effect is stronger in some localities, the difference between the three scenarios is small. This is quite significant and suggests that localization of the NOx emissions to point sources has a more pronounced effect than the absolute reductions achieved. Furthermore it demonstrates that localization of NOx emissions to electricity generating units by using PHEVs in vehicle traffic has beneficial effects for air quality not only by minimizing direct human exposure to motor vehicle emissions, but also due to reduced exposure to secondary pollutants (i.e. ozone). In an electric power grid with a smaller share of fossil fired generating units, the beneficial

  3. New methodology for source location and activity determination in preparation of repairing or decommissioning activities

    International Nuclear Information System (INIS)

    Toubon, H.; Boudergui, K.; Pin, P.; Nohl, B.; Lefevre, S.; Chiron, M.

    2006-01-01

    The operations of dismantling of nuclear installations are often difficult due to the lack of knowledge about the position, the identification and the radiological characteristics of the contamination. To avoid the manual mapping and simply sampling and radiochemical analysis, which takes time and causes doses new tools are now used: - CARTOGAM to detect the position of the activity and the relative dose rates of the different hot spots, - NaI, CZT or Ge gamma spectrometers to characterize the major radionuclides, - a model with ISOCS gamma attenuation code or MERCURAD-PASCALYS gamma attenuation and dose rate evaluation code CARTOGAM and MERCURAD were developed in collaboration with CEA and COGEMA. All these tools are used to build a complete methodology to give adapted solutions to the nuclear facilities. This methodology helps to prepare for and execute decontamination and dismantling activities. After describing the methodology, examples are given of its use in preparation of repairing at an EDF NPP site and in dismantling operations at a CEA site. These examples give concrete insights into their significance and the productivity gains they offer. (authors)

  4. Use of Particle Tracking to Determine Optimal Release Dates and Locations for Rehabilitated Neonate Sea Turtles

    Directory of Open Access Journals (Sweden)

    Natalie A. Robson

    2017-06-01

    Full Text Available Sea turtles found stranded on beaches are often rehabilitated before being released back into the wild. The location and date of release is largely selected on an informal basis, which may not maximize the chance of survival. As oceanic conditions have a large influence on the movements of neonate sea turtles, this study aimed to identify the best locations and months to release rehabilitated sea turtles that would assist in their transport by ocean currents to the habitat and thermal conditions required for their survival. A particle tracking model, forced by ocean surface velocity fields, was used to simulate the dispersal pathways of millions of passively drifting particles released from different locations in Western Australia. The particles represented rehabilitated, neonate turtles requiring oceanic habitats [green (Chelonia mydas, hawksbill (Eretmochelys imbricata and loggerheads (Caretta caretta] and flatback turtles (Natator depressus which require neritic habitats. The results clearly identified regions and months where ocean currents were more favorable for transport to suitable habitats. Tantabiddi, near Exmouth on the north-west coast, was consistently the best location for release for the oceanic species, with dominant offshore-directed currents and a very narrow continental shelf reducing the time taken for particles to be transported into deep water. In contrast, release locations with more enclosed geography, wide continental shelves, and/or proximity to cooler ocean temperatures were less successful. Our results produced a decision support system for the release of neonate marine turtles in Western Australia and our particle tracking approach has global transferability.

  5. Particulate-bound polycyclic aromatic hydrocarbon sources and determinants in residential homes.

    Science.gov (United States)

    Cattaneo, Andrea; Fermo, Paola; Urso, Patrizia; Perrone, Maria Grazia; Piazzalunga, Andrea; Tarlassi, Jessica; Carrer, Paolo; Cavallo, Domenico Maria

    2016-11-01

    Human exposure to polycyclic aromatic hydrocarbons (PAHs) in indoor environments can be particularly relevant because people spend most of their time inside buildings, especially in homes. This study aimed to investigate the most important particle-bound PAH sources and exposure determinants in PM 2.5 samples collected in 19 homes located in northern Italy. Complementary information about ion content in PM 10 was also collected in 12 of these homes. Three methods were used for the identification of PAH sources and determinants: diagnostic ratios with principal component and hierarchical cluster analyses (PCA and HCA), chemical mass balance (CMB) and linear mixed models (LMMs). This combined and tiered approach allowed the infiltration of outdoor PAHs into indoor environments to be identified as the most important source in winter, with a relevant role played by biomass burning and traffic exhausts to be identified as a general source of PAHs in both seasons. Tobacco smoke exhibited an important impact on PAH levels in smokers' homes, whereas in the whole sample, cooking food and natural gas sources played a minor or negligible role. Nitrate, sulfate and ammonium were the main inorganic constituents of indoor PM 10 owing to the secondary formation of ammonium sulfates and nitrates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Analytic model of the stress waves propagation in thin wall tubes, seeking the location of a harmonic point source in its surface

    International Nuclear Information System (INIS)

    Boaratti, Mario Francisco Guerra

    2006-01-01

    Leaks in pressurized tubes generate acoustic waves that propagate through the walls of these tubes, which can be captured by accelerometers or by acoustic emission sensors. The knowledge of how these walls can vibrate, or in another way, how these acoustic waves propagate in this material is fundamental in the detection and localization process of the leak source. In this work an analytic model was implemented, through the motion equations of a cylindrical shell, with the objective to understand the behavior of the tube surface excited by a point source. Since the cylindrical surface has a closed pattern in the circumferential direction, waves that are beginning their trajectory will meet with another that has already completed the turn over the cylindrical shell, in the clockwise direction as well as in the counter clockwise direction, generating constructive and destructive interferences. After enough time of propagation, peaks and valleys in the shell surface are formed, which can be visualized through a graphic representation of the analytic solution created. The theoretical results were proven through measures accomplished in an experimental setup composed of a steel tube finished in sand box, simulating the condition of infinite tube. To determine the location of the point source on the surface, the process of inverse solution was adopted, that is to say, known the signals of the sensor disposed in the tube surface , it is determined through the theoretical model where the source that generated these signals can be. (author)

  7. Determination of Original Infection Source of H7N9 Avian Influenza by Dynamical Model

    Science.gov (United States)

    Zhang, Juan; Jin, Zhen; Sun, Gui-Quan; Sun, Xiang-Dong; Wang, You-Ming; Huang, Baoxu

    2014-05-01

    H7N9, a newly emerging virus in China, travels among poultry and human. Although H7N9 has not aroused massive outbreaks, recurrence in the second half of 2013 makes it essential to control the spread. It is believed that the most effective control measure is to locate the original infection source and cut off the source of infection from human. However, the original infection source and the internal transmission mechanism of the new virus are not totally clear. In order to determine the original infection source of H7N9, we establish a dynamical model with migratory bird, resident bird, domestic poultry and human population, and view migratory bird, resident bird, domestic poultry as original infection source respectively to fit the true dynamics during the 2013 pandemic. By comparing the date fitting results and corresponding Akaike Information Criterion (AIC) values, we conclude that migrant birds are most likely the original infection source. In addition, we obtain the basic reproduction number in poultry and carry out sensitivity analysis of some parameters.

  8. Two Simon tasks with different sources of conflict: an ERP study of motion- and location-based compatibility effects.

    Science.gov (United States)

    Galashan, Daniela; Wittfoth, Matthias; Fehr, Thorsten; Herrmann, Manfred

    2008-07-01

    Behavioral and electrophysiological correlates of two Simon tasks were examined using comparable stimuli but different task-irrelevant and conflict-inducing stimulus features. Whereas target shape was always the task-relevant stimulus attribute, either target location (location-based task) or motion direction within the target stimuli (motion-based task) was used as a source of conflict. Data from ten healthy participants who performed both tasks are presented. In the motion-based task the incompatible condition showed smaller P300 amplitudes at Pz than the compatible condition and the location-based task yielded a trend towards a reduced P300 amplitude in the incompatible condition. For both tasks, no P300 latency differences between the conditions were found at Pz. The results suggest that the motion-based task elicits behavioral and electrophysiological effects comparable with regular Simon tasks. As all stimuli in the motion-based Simon task were presented centrally the present data strongly argue against the attention-shifting account as an explanatory approach.

  9. Consumption of added sugars among US children and adults by food purchase location and food source123

    Science.gov (United States)

    Drewnowski, Adam; Rehm, Colin D

    2014-01-01

    Background: The proposed changes to the Nutrition Facts Label by the US Food and Drug Administration will include information on added sugars for the first time. Objective: The objective was to evaluate the sources of added sugars in the diets of a representative sample of US children and adults by food purchase location and food source (eg, food group). Design: This cross-sectional study among 31,035 children, adolescents, and adults aged ≥6 y from the 2003–2004, 2005–2006, 2007–2008, and 2009–2010 NHANES used data from a 24-h dietary recall to evaluate consumption of added sugars. Food locations of origin were identified as stores (supermarket or grocery store), quick-service restaurants/pizza (QSRs), full-service restaurants (FSRs), schools, and others (eg, vending machines or gifts). Added sugars consumption by food purchase location was evaluated by age, family income-to-poverty ratio, and race-ethnicity. Food group sources of added sugars were identified by using the National Cancer Institute food categories. Results: Added sugars accounted for ∼14.1% of total dietary energy. Between 65% and 76% of added sugars came from stores, 6% and 12% from QSRs, and 4% and 6% from FSRs, depending on age. Older adults (aged ≥51 y) obtained a significantly greater proportion of added sugars from stores than did younger adults. Lower-income adults obtained a significantly greater proportion of added sugars from stores than did higher-income adults. Intake of added sugars did not vary by family income among children/adolescents. Soda and energy and sports drinks were the largest food group sources of added sugars (34.4%), followed by grain desserts (12.7%), fruit drinks (8.0%), candy (6.7%), and dairy desserts (5.6%). Conclusions: Most added sugars came from foods obtained from stores. The proposed changes to the Nutrition Facts Label should capture the bulk of added sugars in the US food supply, which suggests that the recommended changes have the potential to

  10. Sodium intakes of US children and adults from foods and beverages by location of origin and by specific food source.

    Science.gov (United States)

    Drewnowski, Adam; Rehm, Colin D

    2013-05-28

    Sodium intakes, from foods and beverages, of 22,852 persons in the National Health and Nutrition Examination Surveys (NHANES 2003-2008) were examined by specific food source and by food location of origin. Analyses were based on a single 24-h recall. Separate analyses were conducted for children (6-11 years of age), adolescents (12-19), and adults (20-50 and ≥51 years). Grouping of like foods (e.g., food sources) used a scheme proposed by the National Cancer Institute, which divides foods/beverages into 96 food subgroups (e.g., pizza, yeast breads or cold cuts). Food locations of origin were stores (e.g., grocery, convenience and specialty stores), quick-service restaurant/pizza (QSR), full-service restaurant (FSR), school, or other. Food locations of sodium were also evaluated by race/ethnicity amongst adults. Stores provided between 58.1% and 65.2% of dietary sodium, whereas QSR and FSR together provided between 18.9% and 31.8% depending on age. The proportion of sodium from QSR varied from 10.1% to 19.9%, whereas that from FSR varied from 3.4% to 13.3%. School meals provided 10.4% of sodium for 6-11 year olds and 6.0% for 12-19 year olds. Pizza from QSR, the top away from home food item, provided 5.4% of sodium in adolescents. QSR pizza, chicken, burgers and Mexican dishes combined provided 7.8% of total sodium in adult diets. Most sodium came from foods purchased in stores. Food manufacturers, restaurants, and grocery stores all have a role to play in reducing the amount of sodium in the American diet.

  11. A Diagnostic Test for Determining the Location of the GeV Emission in Powerful Blazars

    Science.gov (United States)

    Dotson, Amanda; Georganopoulos, Markos; Kazanas, Demosthenes; Perlman, Eric

    2011-01-01

    An issue currently under debate in the literature is how far from the black hole is the Fermi-observed GeV emission of powerful blazars emitted. Here we present a clear diagnostic tool for testing whether the Ge V emission site is located within the sub-pc broad emission line (BLR) region or further out in the few pc scale molecular torus (MT) environment. Within the BLR the scatteri takes place at the onset of the Klein-Nishina regime, causing the electron cooling time to become almost energy independent and as a result, the variation of high-energy emission is expected to be achromatic. Contrarily, if the emission site is located outside the BLR, the expected GeY variability is energy-dependent and with amplitude increasing with energy. We demonstrate this using time-dependent numerical simulations of blazar variability.

  12. Influence of the faces relative arrangement on the optimal reloading station location and analytical determination of its coordinates

    Directory of Open Access Journals (Sweden)

    V.К. Slobodyanyuk

    2017-04-01

    Full Text Available The purpose of this study is to develop a methodology of the optimal rock mass run-of-mine (RoM stock point determination and research of the influence of faces spatial arrangement on this point. The research represents an overview of current researches, where algorithms of the Fermat-Torricelli-Steiner point are used in order to minimize the logistic processes. The methods of mathematical optimization and analytical geometry were applied. Formulae for the optimal point coordinates determination for a 4 faces were established using the latter methods. Mining technology with use of reloading stations is rather common at the deep iron ore pits. In most cases, when deciding on location of RoM stock, its high-altitude position in space of the pit is primarily taken into account. However, the location of the reloading station in a layout also has a significant influence on technical and economic parameters of open-pit mining operations. The traditional approach, which considers a point of the center of gravity as an optimal point for RoM stock location, does not guarantee the minimum haulage. In mathematics, the Fermat-Torricelli point that provides a minimum distance to the vertices of the triangle is known. It is shown that the minimum haulage is provided when the point of RoM stock location and Fermat-Torricelli point coincide. In terms of open pit mining operations, the development of a method that will determine an optimal point of RoM stock location for a working area with respect to the known coordinates of distinguished points on the basis of new weight factors is of particular practical importance. A two-stage solution to the problem of determining the rational point of RoM stock location (with a minimal transport work for any number of faces is proposed. Such optimal point for RoM stock location reduces the transport work by 10–20 %.

  13. Determination of Key Risk Supervision Areas around River-Type Water Sources Affected by Multiple Risk Sources: A Case Study of Water Sources along the Yangtze’s Nanjing Section

    Directory of Open Access Journals (Sweden)

    Qi Zhou

    2017-02-01

    Full Text Available To provide a reference for risk management of water sources, this study screens the key risk supervision areas around river-type water sources (hereinafter referred to as the water sources threatened by multiple fixed risk sources (the risk sources, and establishes a comprehensive methodological system. Specifically, it comprises: (1 method of partitioning risk source concentrated sub-regions for screening water source perimeter key risk supervision areas; (2 approach of determining sub-regional risk indexes (SrRI, which characterizes the scale of sub-regional risks considering factors like risk distribution intensity within sub-regions, risk indexes of risk sources (RIRS, characterizing the risk scale of risk sources and the number of risk sources; and (3 method of calculating sub-region’s risk threats to the water sources (SrTWS which considers the positional relationship between water sources and sub-regions as well as SrRI, and the criteria for determining key supervision sub-regions. Favorable effects are achieved by applying this methodological system in determining water source perimeter sub-regions distributed along the Yangtze’s Nanjing section. Results revealed that for water sources, the key sub-regions needing supervision were SD16, SD06, SD21, SD26, SD15, SD03, SD02, SD32, SD10, SD11, SD14, SD05, SD27, etc., in the order of criticality. The sub-region with the greatest risk threats on the water sources was SD16, which was located in the middle reaches of Yangtze River. In general, sub-regions along the upper Yangtze reaches had greater threats to water sources than the lower reach sub-regions other than SD26 and SD21. Upstream water sources were less subject to the threats of sub-regions than the downstream sources other than NJ09B and NJ03.

  14. Cloud Fingerprinting: Using Clock Skews To Determine Co Location Of Virtual Machines

    Science.gov (United States)

    2016-09-01

    expenses. However, because the cloud infrastructure is located off-site from an organization and the cloud is available to anyone who pays for its...Defense DNS Domain Name Service EC2 Elastic Cloud Computing EoR End of Row GCE Google Compute Engine IaaS Infrastructure -as-a-Service ICMP Internet...de facto method for both managing and processing this data [1]. The high demand for cloud services has caused many companies to offer easy solutions at

  15. A Linear Programming Approach for Determining Travel Cost Minimizing ECSS Training Locations

    Science.gov (United States)

    2010-03-01

    can accommodate the simultaneous training of many personnel. 1. Gulfport CRTC, Mississippi 2. Savannah CRTC, Georgia 3. Alpena CRTC, Michigan 4...327 224 Savannah CRTC 266 182 Alpena CRTC 493 343 Volk Field CRTC 136 91 Hill ALC 210 147 Hanscom ALC 414 287 Tinker ALC 620 434 Robins ALC 1332...Location Frequency within Optimal Solutions across All Phases 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Gulfport CRTC Savannah CRTC Alpena CRTC Volk

  16. Octopus vulgaris uses visual information to determine the location of its arm.

    Science.gov (United States)

    Gutnick, Tamar; Byrne, Ruth A; Hochner, Binyamin; Kuba, Michael

    2011-03-22

    Octopuses are intelligent, soft-bodied animals with keen senses that perform reliably in a variety of visual and tactile learning tasks. However, researchers have found them disappointing in that they consistently fail in operant tasks that require them to combine central nervous system reward information with visual and peripheral knowledge of the location of their arms. Wells claimed that in order to filter and integrate an abundance of multisensory inputs that might inform the animal of the position of a single arm, octopuses would need an exceptional computing mechanism, and "There is no evidence that such a system exists in Octopus, or in any other soft bodied animal." Recent electrophysiological experiments, which found no clear somatotopic organization in the higher motor centers, support this claim. We developed a three-choice maze that required an octopus to use a single arm to reach a visually marked goal compartment. Using this operant task, we show for the first time that Octopus vulgaris is capable of guiding a single arm in a complex movement to a location. Thus, we claim that octopuses can combine peripheral arm location information with visual input to control goal-directed complex movements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Inter fractional variability of breathing phase definition as determined by fiducial location

    International Nuclear Information System (INIS)

    Killoran, Joseph H.; Allen, Aaron M.; Kann, Benjamin H.; Lyatskaya, Yulia

    2008-01-01

    Reconstruction of four-dimensional (4D) imaging typically requires an externally measurable surrogate to represent the real-time relative phase of respiration. A common method is to use a reflective marker on the external surface of the patient which moves with respiration and can be tracked in real time. The location of the marker is often chosen to maximize the observable motion, though this location may not be at the region of interest. We evaluate the importance of infrared (IR) marker placement location on breathing phase definition for the purpose of respiratory gating and 4D computed tomography (CT) image reconstruction. Data were collected for ten patients enrolled on an approved IRB protocol. Real-time position data were collected during CT imaging and daily treatments for two external IR reflective markers: one placed near the xyphoid and another at the approximate location of the treatment isocenter. Motion traces from the markers were compared using cross-correlation coefficient and by estimating the relative respiratory phase, based on either marker, as would be used for 4D-CT reconstruction. Cross-correlation analysis revealed differences in the motion waveform, as well as phase differences, both of which were variable between patients as well as day to day for the same patient. Estimated relative phases from each marker were compared by the percentage amount of time the estimated phase for each marker was different, binned based on increments of 10% of a full cycle. For all collected data combined, the frequency with which breathing phase mismatch led to different bin allocation in steps of 10% was as follows: T 010% =65.1%, T 1020% =25.3%, T 2030% =7.8%, T 3040% =1.5% and T 4050% =0.4%. Based on ten images per cycle, this indicates that 4D reconstructions would be influenced, depending on which marker was used, by at least 1 bin 34.9% of the time. This number was noticeably higher for some patients; the maximum was 71% of the time for one patient of

  18. Determination of the neutron spectrum at different locations in the Argentine RA-1 Reactor

    International Nuclear Information System (INIS)

    Lerner, A.M.; Madariaga, M.R.

    1998-01-01

    Full text: It is well known that the RA-1 reactor is used to irradiate different types of materials with neutrons. The Radio dosimetry Group (which belongs to the Nuclear Regulatory Authority) uses its fast column for the design, calibration and set up of criticality dosimeters as well as for a quick assessment of the dose to workers in case of an accident. With such purpose, Au(1), Au under Cd and In(2) foils were irradiated to estimate absolute thermal, epithermal and fast neutron fluxes at the irradiation location. The accuracy of this estimation is higher when the response to the present neutron spectrum of the different materials constituting the detectors is better known. This, in turn, requires the previous knowledge of such spectrum (a detailed energy dependence of neutron flux) at the analysed location. In this work a neutronic calculation is presented at the fast irradiation location. The whole calculation was carried out following two different methodologies, and considering a power of 40 kW. The reactor and its surroundings were represented by a simplified one-dimensional model, as a concentric cylindrical set of regions. Figures are drawn representing fast and thermal fluxes (with the cut at 0.4 eV) as a function of the distance to the core centre. The neutron flux (in n/cm 2 sec.eV) as a function of energy is also shown at the fast irradiation location. Values of flux (in n/cm 2 .sec.eV) are also provided as a function of energy in other typical locations, as well as the equivalent integrated flux values (in n/cm 2 .sec). ((1) According to the reaction Au 197 (n,γ)Au 198 , having a cross section of σ 0 =98.8b for thermal neutrons. (2) According to the reaction In 115 (n,n')In 115m , with a cross section of some 70 mb for neutrons with energies above 1.2MeV). (author) [es

  19. Determining suitable locations for seed transfer under climate change: a global quantitative method

    Science.gov (United States)

    Kevin M. Potter; William W. Hargrove

    2012-01-01

    Changing climate conditions will complicate efforts to match seed sources with the environments to which they are best adapted. Tree species distributions may have to shift to match new environmental conditions, potentially requiring the establishment of some species entirely outside of their current distributions to thrive. Even within the portions of tree species...

  20. Non-traditional Physics-based Inverse Approaches for Determining a Buried Object’s Location

    Science.gov (United States)

    2008-09-01

    parameterization of its time-decay curve) in dipole models ( Pasion and Oldenburg, 2001) or the amplitudes of responding magnetic sources in the NSMS...commonly in use. According to the simple dipole model ( Pasion and Oldenburg, 2001), the secondary magnetic field due to the dipole m is 3 0 1 ˆ ˆ(3...Forum, St. Louis, MO. L. R. Pasion and D. W. Oldenburg (2001), “A discrimination algorithm for UXO using time domain electromagnetics.” J. Environ

  1. Positron annihilation lifetime spectroscopy source correction determination: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, Gurmeet S.; Keeble, David J., E-mail: d.j.keeble@dundee.ac.uk

    2016-02-01

    Positron annihilation lifetime spectroscopy (PALS) can provide sensitive detection and identification of vacancy-related point defects in materials. These measurements are normally performed using a positron source supported, and enclosed by, a thin foil. Annihilation events from this source arrangement must be quantified and are normally subtracted from the spectrum before analysis of the material lifetime components proceeds. Here simulated PALS spectra reproducing source correction evaluation experiments have been systematically fitted and analysed using the packages PALSfit and MELT. Simulations were performed assuming a single lifetime material, and for a material with two lifetime components. Source correction terms representing a directly deposited source and various foil supported sources were added. It is shown that in principle these source terms can be extracted from suitably designed experiments, but that fitting a number of independent, nominally identical, spectra is recommended.

  2. USING GROUND PENETRATING RADAR TO DETERMINE THE TUNNEL LOCATION BURIED UNDER THE GLACIER

    Directory of Open Access Journals (Sweden)

    Deryuga Andrey Mikhaylovich

    2013-09-01

    Full Text Available The works were carried out with the help of ground penetrating radar “Grot-10”. Doublet broadband antennas with the central frequency of 100 MHz were used. Georadar measures the speed of EM waves v in ice-saturated soil and then the value ε′ is calculated. The radargrams received as a result of georadar survey, which represents stacked data (the two-way time is indicated on vertical scale, were transformed into depth sections, which reflect the space structure located below ground. The distance between the bottom landing and buried mountain road near the north tunnel portal is 78,5 m (profile # 1, and the distance from the upper landing is 84,5 m (profile no. 2. Later, in the April 2003 during the hole boring with the diameter 1,2 m the vertical distance between the upper landing, where ground penetrating works were carried out, and the carpet road of the tunnel was calculated. This distance appeared to be 83 m, that means, the discrepancy between boring and georadar data (84,5 m was only 1,5 m. Thus, the results of ground penetrating investigations helped the workers of glacier to make the correct conclusion on time about the location and burial depth of the tunnel.

  3. Earthquake locations determined by the Southern Alaska seismograph network for October 1971 through May 1989

    Science.gov (United States)

    Fogleman, Kent A.; Lahr, John C.; Stephens, Christopher D.; Page, Robert A.

    1993-01-01

    This report describes the instrumentation and evolution of the U.S. Geological Survey’s regional seismograph network in southern Alaska, provides phase and hypocenter data for seismic events from October 1971 through May 1989, reviews the location methods used, and discusses the completeness of the catalog and the accuracy of the computed hypocenters. Included are arrival time data for explosions detonated under the Trans-Alaska Crustal Transect (TACT) in 1984 and 1985.The U.S. Geological Survey (USGS) operated a regional network of seismographs in southern Alaska from 1971 to the mid 1990s. The principal purpose of this network was to record seismic data to be used to precisely locate earthquakes in the seismic zones of southern Alaska, delineate seismically active faults, assess seismic risks, document potential premonitory earthquake phenomena, investigate current tectonic deformation, and study the structure and physical properties of the crust and upper mantle. A task fundamental to all of these goals was the routine cataloging of parameters for earthquakes located within and adjacent to the seismograph network.The initial network of 10 stations, 7 around Cook Inlet and 3 near Valdez, was installed in 1971. In subsequent summers additions or modifications to the network were made. By the fall of 1973, 26 stations extended from western Cook Inlet to eastern Prince William Sound, and 4 stations were located to the east between Cordova and Yakutat. A year later 20 additional stations were installed. Thirteen of these were placed along the eastern Gulf of Alaska with support from the National Oceanic and Atmospheric Administration (NOAA) under the Outer Continental Shelf Environmental Assessment Program to investigate the seismicity of the outer continental shelf, a region of interest for oil exploration. Since then the region covered by the network remained relatively fixed while efforts were made to make the stations more reliable through improved electronic

  4. Multi-criteria optimization for determining installation locations for the power-to-gas technologies

    OpenAIRE

    Moskalenko, Natalia; Lombardi, Pio Alessandro; Komarnicki, Przemyslaw

    2014-01-01

    The steady rise of the integration of renewable energy sources (RES) has led to a re-examination of existing energy storage technologies as well as the development of new ones, e.g. power-to-gas (P2G) technology. This technology uses surplus of electricity from RES to create the synthetic natural gas, which can be stored for long periods of time, and thus it can significantly support the integration of RES into the existing power grid and extend a system transmission capacity, which is needed...

  5. Design of Experiments to Determine Causes of Flex Cable Solder Wicking, Discoloration and Hole Location Defects

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, Larry

    2009-04-22

    Design of Experiments (DoE) were developed and performed in an effort to discover and resolve the causes of three different manufacturing issues; large panel voids after Hot Air Solder Leveling (HASL), cable hole locations out of tolerance after lamination and delamination/solder wicking around flat flex cable circuit lands after HASL. Results from a first DoE indicated large panel voids could be eliminated by removing the pre-HASL cleaning. It also revealed eliminating the pre-HASL bake would not be detrimental when using a hard press pad lamination stackup. A second DoE indicated a reduction in hard press pad stackup lamination pressure reduced panel stretch in the y axis approximately 70%. A third DoE illustrated increasing the pre-HASL bake temperature could reduce delamination/solder wicking when using a soft press pad lamination stackup.

  6. Efficacy of CTA portography for preoperatively determining the segmental location of focal hepatic lesions

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chemzmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1989-01-01

    Using cross-sectional images to localize tumors to specific hepatic segments before resection might be difficult because the transverse scissura, an important segmental landmark, is approximately parallel to the axial plane. Since this plane is parallel to the main right and left portal pedicles, the authors postulated that they could localize lesions above this plane to segments 2,4A,7, or 8, and below this plane to segments 3, 4B,5, or 6. The authors have retrospectively evaluated, in a blinded fashion, 24 hepatic masses in 13 patients who underwent CTA-portography and subsequent tumor resection. Using this scheme, they have accurately predicted the primary segmental location in 22 (92%) of 24 surgically confirmed lesions

  7. Determinants of SME location in a suburban area: Evidence from the Gdańsk–Gdynia–Sopot Metropolitan Area

    Directory of Open Access Journals (Sweden)

    Justyna Martyniuk-Pęczek

    2017-06-01

    Full Text Available Given the importance of small and medium enterprises (SMEs in the European economy, it is essential to have adequate information about the various factors that determine their choice of location. However, the size of a company is often an aspect not covered in theoretical studies and empirical research on industrial locations and urban planning. This article examines the place of residence as a stimulator of SME development in suburbs. Multidisciplinary research carried out in the Gdańsk–Gdynia–Sopot Metropolitan Area, known as the Tricity, confirms this trend. The location determinants of SMEs in suburban areas were identified using a questionnaire. The survey was conducted in 251 enterprises located in seven municipalities with the highest suburbanisation rates within the Tricity. The study confirms that the municipalities characterised by the highest intensity of suburbanisation processes have higher business activity than other municipalities. Location decisions were largely made by business owners in line with behavioural theory. This means that SME owners more often consider personal factors than cost or demand factors. From the perspective of an entrepreneur, living conditions, the quality of public space, education and healthcare are significant.

  8. Sources of Information as Determinants of Product and Process Innovation

    OpenAIRE

    G?mez, Jaime; Salazar, Idana; Vargas, Pilar

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are ...

  9. Is rectal MRI beneficial for determining the location of rectal cancer with respect to the peritoneal reflection?

    International Nuclear Information System (INIS)

    Jung, Eun Joo; Ryu, Chun Geun; Kim, Gangmi; Kim, Su Ran; Nam, Sang Eun; Park, Hee Sun; Kim, Young Jun; Hwang, Dae-Yong

    2012-01-01

    An objective method for determining the location of the cancer with respect to peritoneal reflection would be helpful to decide the treatment modality for rectal cancer. This study was designed to evaluate the accuracy and usefulness of rectal MRI to determine spatial relations between the peritoneal reflection and rectal cancer and to compare these with operative findings. Patients that underwent a rectal cancer operation after a rectal MRI check between November 2008 and June 2010 were considered for the study. The patients that received preoperative concurrent chemoradiation or trans-anal local excision were excluded. Fifty-four patients constituted the study cohort. By comparing surgical and radiologic findings, the accuracy for predicting tumour location in relation to the peritoneal reflection by rectal MRI in all patients was 90.7%. In terms of tumour location in relation to peritoneal reflection, the accuracy of rectal MRI was 93.5% in patients with a tumour located above the peritoneal reflection, 90.0% in patients with a tumour located on the peritoneal reflection, and 84.6% in patients with a tumour located below the peritoneal reflection (p=0.061). When the cohort was subdivided by gender, body mass index (BMI), operative findings, or tumour size, no significant difference was observed among subgroups. Rectal MRI could be a useful tool for evaluating the relation between rectal cancer and peritoneal reflection especially when tumour size is less than 8cm. Rectal MRI can provide information regarding the location of rectal cancer in relation to the peritoneal reflection for treatment planning purposes

  10. Application of a water quality model for determining instream aeration station location and operational rules: A case study

    Directory of Open Access Journals (Sweden)

    Charles S. Melching

    2018-01-01

    Full Text Available Instream aeration has been used as a supplement to secondary treatment or a substitute for tertiary treatment for meeting dissolved oxygen (DO standards in rivers. Many studies have used water quality models to determine the number, location, and capacity of instream aeration stations (IASs needed to meet DO standards in combination with other pollution control measures. DO concentrations have been improved in the North Shore Channel and North Branch Chicago River by the Devon Avenue IAS for more than 35 years. A study was initiated to determine whether it was better to rehabilitate or relocate this station and to determine appropriate operational guidance for the IAS at the selected location. A water quality model capable of simulating DO concentrations during unsteady flow was used to evaluate the proper location for an IAS and operational guidance for this IAS. Three test years, a dry year, a wet year, and an extreme year, were considered in the evaluation. The study found that the Devon Avenue IAS should be rehabilitated as this location performed as well as or better than any of 10 alternative locations. According to the new operational guidance for this IAS, the amount of time with blowers operating could be substantially reduced compared to traditional operations while at the same time the attainment of the DO standards could be increased. This study shows that a carefully designed modeling study is key to effective selection, location, and operation of IASs such that attainment of DO standards can be maximized while operation hours of blowers can be minimized. Keywords: Instream aeration, Dissolved oxygen, Water quality modeling, Water quality management, Computer simulation

  11. Sources of Information as Determinants of Product and Process Innovation.

    Science.gov (United States)

    Gómez, Jaime; Salazar, Idana; Vargas, Pilar

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process) considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent.

  12. Sources of Information as Determinants of Product and Process Innovation.

    Directory of Open Access Journals (Sweden)

    Jaime Gómez

    Full Text Available In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent.

  13. Sources of Information as Determinants of Product and Process Innovation

    Science.gov (United States)

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process) considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent. PMID:27035456

  14. Comparison of Hydraulic Conductivity Determinations in Co-located Conventional and Direct-Push Monitoring Wells

    Science.gov (United States)

    2011-03-08

    and Development Center (ERDC) provided the funding for this project. We wish to thank our project monitors Tony Bednar (ERDC Environmental Laboratory...method for field determination of hy- draulic conductivity at contaminated sites (Butler 1997; Henebry and Robbins 2000; Bartlett et al. 2004). For a...ASTM International. www.astm.org Bartlett, Stephen A., Gary A. Robbins , J. Douglas Mandrick, Michael Barcelona, Wes McCall, and Mark Kram. 2004

  15. Determination of Flaw Type and Location Using an Expert Module in Ultrasonic Nondestructive Testing for Weld Inspection

    Science.gov (United States)

    Shahriari, D.; Zolfaghari, A.; Masoumi, F.

    2011-01-01

    Nondestructive evaluation is explained as nondestructive testing, nondestructive inspection, and nondestructive examination. It is a desire to determine some characteristic of the object or to determine whether the object contains irregularities, discontinuities, or flaws. Ultrasound based inspection techniques are used extensively throughout industry for detection of flaws in engineering materials. The range and variety of imperfections encountered is large, and critical assessment of location, size, orientation and type is often difficult. In addition, increasing quality requirements of new standards and codes of practice relating to fitness for purpose are placing higher demands on operators. Applying of an expert knowledge-based analysis in ultrasonic examination is a powerful tool that can help assure safety, quality, and reliability; increase productivity; decrease liability; and save money. In this research, an expert module system is coupled with ultrasonic examination (A-Scan Procedure) to determine and evaluate type and location of flaws that embedded during welding parts. The processing module of this expert system is implemented based on EN standard to classify welding defects, acceptance condition and measuring of their location via echo static pattern and image processing. The designed module introduces new system that can automate evaluating of the results of A-scan method according to EN standard. It can simultaneously recognize the number and type of defects, and determine flaw position during each scan.

  16. Determining Correlation between Shark Location and Atmospheric Wind and Thermal Parameters.

    Science.gov (United States)

    Merchant, J.

    2017-12-01

    Millions of people visit the nation's shorelines every summer. As recreational use of the ocean increases across the country, so too does the risk of shark attacks on people. According to George H. Burgess, curator for the International Shark Attack File and the Florida Program for Shark Research "The number of shark-human interactions occurring in a given year is directly correlated with the amount of time humans spend in the sea. As world population continues its upsurge and interest in aquatic recreation concurrently rises, we realistically should expect increases in the number of shark attacks and other aquatic recreation-related injuries". Burgess' analysis released in February of 2016, states "2015 yearly total of 98 unprovoked attacks (worldwide) was the highest on record" until 2016. Adding to the previous record number of global shark/human interactions in 2015 were 10 confirmed cases of people bitten by sharks off the shores of North Carolina and South Carolina over a five week period in June and July of 2015. The unusually high amount of attacks within close proximity over a short period of time garnered significant media attention nationwide. Preliminary data resulting from the analysis of these 2015 shark attacks and separate acoustic shark location data from Dr. Gregory Skomal's (Program Manager, Senior Marine Fisheries Biologist for the state of Massachusetts) ongoing research across Cape Code do indicate a correlation between environmental and biological factors leading up to human/shark interactions. Not only will these preliminary findings be presented, but a full description of how the use of higher resolution remote sensing and in-situ surface wind and thermal measurements would improve real time detection and prediction of these dangerous conditions, up to hours in advance, mitigating human risk and interaction with shark.

  17. Location of lesion determines motor vs. cognitive consequences in patients with cerebellar stroke

    Directory of Open Access Journals (Sweden)

    Catherine J. Stoodley

    2016-01-01

    Full Text Available Cerebellar lesions can cause motor deficits and/or the cerebellar cognitive affective syndrome (CCAS; Schmahmann's syndrome. We used voxel-based lesion-symptom mapping to test the hypothesis that the cerebellar motor syndrome results from anterior lobe damage whereas lesions in the posterolateral cerebellum produce the CCAS. Eighteen patients with isolated cerebellar stroke (13 males, 5 females; 20–66 years old were evaluated using measures of ataxia and neurocognitive ability. Patients showed a wide range of motor and cognitive performance, from normal to severely impaired; individual deficits varied according to lesion location within the cerebellum. Patients with damage to cerebellar lobules III–VI had worse ataxia scores: as predicted, the cerebellar motor syndrome resulted from lesions involving the anterior cerebellum. Poorer performance on fine motor tasks was associated primarily with strokes affecting the anterior lobe extending into lobule VI, with right-handed finger tapping and peg-placement associated with damage to the right cerebellum, and left-handed finger tapping associated with left cerebellar damage. Patients with the CCAS in the absence of cerebellar motor syndrome had damage to posterior lobe regions, with lesions leading to significantly poorer scores on language (e.g. right Crus I and II extending through IX, spatial (bilateral Crus I, Crus II, and right lobule VIII, and executive function measures (lobules VII–VIII. These data reveal clinically significant functional regions underpinning movement and cognition in the cerebellum, with a broad anterior-posterior distinction. Motor and cognitive outcomes following cerebellar damage appear to reflect the disruption of different cerebro-cerebellar motor and cognitive loops.

  18. Locations of oxygen, nitrogen and carbon atoms in vanadium determined by neutron diffraction

    International Nuclear Information System (INIS)

    Hiraga, K.; Onozuka, T.; Hirabayashi, M.

    1977-01-01

    The occupation sites of oxygen, nitrogen, and carbon atoms dissolved interstitially in vanadium have been determined by means of neutron diffraction with use of single crystals of VOsub(0.032), VNsub(0.013) and VCsub(0.006). It is revealed that the interstitial atoms occupy, randomly, the octahedral sites in the b.c.c. host lattice of the three crystals. Neutron diffraction is advantageous for the present purpose, since the coherent scattering amplitudes of the solute atoms are much larger than that of the vanadium atom. (Auth.)

  19. Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study.

    Science.gov (United States)

    ElAyouti, A; Kimionis, I; Chu, A-L; Löst, C

    2005-11-01

    To assess ex vivo the accuracy of various electronic apex locators in locating the apical terminus of root-end resected teeth. Ninety extracted human posterior teeth (182 root canals) were prepared to a minimum size of 40 and filled with gutta-percha and sealer. After resection of the apical 3 mm of the root, the root canal filling was removed using HERO rotary instruments. The size of the root canal at the apical terminus after removal of the filling ranged from size 50 to 90. The root canal length to the apical terminus was determined using 3 apex locators (Root ZX, Raypex4 and Apex Pointer). A new mounting model that utilized a micrometer was used to perform the measurements and to visually determine the actual position of the apical terminus. The frequency of locating the apical terminus and the corresponding 95% confidence interval (CI) were calculated. Additionally, the coefficient of repeatability of each apex locator and the limits of inter-operator agreement were determined. All apex locators showed an acceptable repeatability (0.02-0.03 mm coefficient of repeatability) and narrow limits of inter-operator agreement (+0.07 and -0.07 mm). The accuracy of determining the apical terminus within 1 mm in the root canal was as follows: Root ZX 90% (164/182 root-canals) [95%CI: 86-94%], Raypex4 74% (135/182 root-canals) [95%CI: 68-80%], and Apex Pointer 71% (129/182 root canals) [95%CI: 65-77%]. No over-instrumentation resulted when the Root ZX device was used. In contrast, using the Raypex4 or the Apex Pointer device resulted in over-instrumentation in 8 of 182 root canals (4%). Under the conditions of this study all three apex locators were able to detect the apical terminus of root-end resected teeth with an acceptable range. The Root ZX device was the most accurate without over-instrumentation of the root canals.

  20. Factors determining family planning in Catalonia. Sources of inequity

    Directory of Open Access Journals (Sweden)

    Saurina Carme

    2012-07-01

    Full Text Available Abstract Introduction In recent decades, the foreign population in Spain has increased significantly, particularly for Catalonia, an autonomous region of Spain (2.90% in 2000 and 15.95% in 2010 and in particular Girona province (6.18% in 2000 and 21.55% in 2010. Several studies have shown a lower use of family planning methods by immigrants. This same trend is observed in Spain. The objective of this paper is to determine the existence of differences and possible sources of inequity in the use of family planning methods among health service users in Catalonia (Spain by sex, health status, place of birth and socioeconomic conditions. Methods Data were taken from an ad-hoc questionnaire which was compiled following a qualitative stage of individual interviews. Said questionnaire was administered to 1094 Catalan public health service users during 2007. A complete descriptive analysis was carried out for variables related to public health service users’ sociodemographic characteristics and variables indicating knowledge and use of family planning methods, and bivariate relationships were analysed by means of chi-square contrasts. Considering the use (or non-use of family planning methods as a dependent variable and a set of demographic, socioeconomic and health status variables as explanatory factors, the relationship was modelled using mixed models. Results The analysed sample is comprised of 54.3% women and 45.7% men, with 74.3% natives (or from the EU and 25.7% economic immigrants. 54.8% use some method of family planning, the condom (46.7% and the pill (28.0% being the two most frequently used methods. Statistical modelling indicates that those factors which most influence the use of family planning methods are level of education (30.59% and 39.29% more likelihood and having children over 14 (35.35% more likelihood. With regard to the origin of the user, we observe that patients from North Africa,sub. Saharan Africa and Asia are less likely to

  1. Factors determining family planning in Catalonia. Sources of inequity.

    Science.gov (United States)

    Saurina, Carme; Vall-Llosera, Laura; Saez, Marc

    2012-07-20

    In recent decades, the foreign population in Spain has increased significantly, particularly for Catalonia, an autonomous region of Spain (2.90% in 2000 and 15.95% in 2010) and in particular Girona province (6.18% in 2000 and 21.55% in 2010). Several studies have shown a lower use of family planning methods by immigrants. This same trend is observed in Spain. The objective of this paper is to determine the existence of differences and possible sources of inequity in the use of family planning methods among health service users in Catalonia (Spain) by sex, health status, place of birth and socioeconomic conditions. Data were taken from an ad-hoc questionnaire which was compiled following a qualitative stage of individual interviews. Said questionnaire was administered to 1094 Catalan public health service users during 2007. A complete descriptive analysis was carried out for variables related to public health service users' sociodemographic characteristics and variables indicating knowledge and use of family planning methods, and bivariate relationships were analysed by means of chi-square contrasts. Considering the use (or non-use) of family planning methods as a dependent variable and a set of demographic, socioeconomic and health status variables as explanatory factors, the relationship was modelled using mixed models. The analysed sample is comprised of 54.3% women and 45.7% men, with 74.3% natives (or from the EU) and 25.7% economic immigrants. 54.8% use some method of family planning, the condom (46.7%) and the pill (28.0%) being the two most frequently used methods. Statistical modelling indicates that those factors which most influence the use of family planning methods are level of education (30.59% and 39.29% more likelihood) and having children over 14 (35.35% more likelihood). With regard to the origin of the user, we observe that patients from North Africa,sub. Saharan Africa and Asia are less likely to use family planning methods (36.68%, 38.59% and 70

  2. Knee Kinematics During Noncontact Anterior Cruciate Ligament Injury as Determined From Bone Bruise Location.

    Science.gov (United States)

    Kim, Sophia Y; Spritzer, Charles E; Utturkar, Gangadhar M; Toth, Alison P; Garrett, William E; DeFrate, Louis E

    2015-10-01

    The motions causing noncontact anterior cruciate ligament (ACL) injury remain unclear. Tibiofemoral bone bruises are believed to be the result of joint impact near the time of ACL rupture. The locations and frequencies of these bone bruises have been reported, but there are limited data quantifying knee position and orientation near the time of injury based on these contusions. Knee position and orientation near the time of noncontact ACL injury include extension and anterior tibial translation. Descriptive laboratory study. Magnetic resonance images of 8 subjects with noncontact ACL injuries were acquired within 1 month of injury and were subsequently analyzed. All subjects exhibited bruises on both the femur and tibia in both medial and lateral compartments. The outer margins of bone and the bone bruise surfaces were outlined on each image to create a 3-dimensional model of each subject's knee in its position during magnetic resonance imaging (MRI position). Numerical optimization was used to maximize overlap of the bone bruises on the femur and tibia and to predict the position of injury. Flexion angle, valgus orientation, internal tibial rotation, and anterior tibial translation were measured in both the MRI position and the predicted position of injury. Differences in kinematics between the MRI position, which served as an unloaded reference, and the predicted position of injury were compared by use of paired t tests. Flexion angle was near full extension in both the MRI position and the predicted position of injury (8° vs 12°; P = .2). Statistically significant increases in valgus orientation (5°; P = .003), internal tibial rotation (15°; P = .003), and anterior tibial translation (22 mm; P injury relative to the MRI position. These results suggest that for the bone bruise pattern studied, landing on an extended knee is a high risk for ACL injury. Extension was accompanied by increased anterior tibial translation (22 mm), internal tibial rotation (15

  3. Sources of Caffeine in Diets of US Children and Adults: Trends by Beverage Type and Purchase Location

    Science.gov (United States)

    Drewnowski, Adam; Rehm, Colin D.

    2016-01-01

    New sources of caffeine, besides coffee and tea, have been introduced into the US food supply. Data on caffeine consumption age and purchase location can help guide public health policy. National Health and Nutrition Examination Surveys (NHANES) were used to estimate population-level caffeine intakes, using data from 24-h dietary recall. First, caffeine intakes by age-group and beverage type were estimated using the most recent 2011–2012 data (n = 7456). Second, fourteen years trends in caffeine consumption, overall and by beverage type, were evaluated for adults and children. Trend analyses were conducted by age groups. Last, trends in caffeine intakes by purchase location and beverage type were estimated. In 2011–2012, children aged four to eight years consumed the least caffeine (15 mg/day), and adults aged 51–70 years consumed the most (213 mg/day). The population mean (age ≥ four years) was 135 mg/day, driven largely by coffee (90 mg/day), tea (25 mg/day), and soda (21 mg/day). For the 14–19 years and 20–34 years age-groups, energy drinks contributed 6 mg/day (9.9%) and 5 mg/day (4.5%), respectively. The bulk of caffeine came from store-bought coffee and tea. Among both children and adults combined, caffeine intakes declined from 175 mg/day (1999–2000) to 142 mg/day (2011–2012), largely driven by a drop in caffeine from soda (41 mg/day to 21 mg/day). Store-bought coffee and tea remain principal drivers of caffeine intake in the US. Sodas and energy drinks make minor contributions to overall caffeine intakes. PMID:26978391

  4. Sources of Caffeine in Diets of US Children and Adults: Trends by Beverage Type and Purchase Location.

    Science.gov (United States)

    Drewnowski, Adam; Rehm, Colin D

    2016-03-10

    New sources of caffeine, besides coffee and tea, have been introduced into the US food supply. Data on caffeine consumption age and purchase location can help guide public health policy. National Health and Nutrition Examination Surveys (NHANES) were used to estimate population-level caffeine intakes, using data from 24-h dietary recall. First, caffeine intakes by age-group and beverage type were estimated using the most recent 2011-2012 data (n = 7456). Second, fourteen years trends in caffeine consumption, overall and by beverage type, were evaluated for adults and children. Trend analyses were conducted by age groups. Last, trends in caffeine intakes by purchase location and beverage type were estimated. In 2011-2012, children aged four to eight years consumed the least caffeine (15 mg/day), and adults aged 51-70 years consumed the most (213 mg/day). The population mean (age ≥ four years) was 135 mg/day, driven largely by coffee (90 mg/day), tea (25 mg/day), and soda (21 mg/day). For the 14-19 years and 20-34 years age-groups, energy drinks contributed 6 mg/day (9.9%) and 5 mg/day (4.5%), respectively. The bulk of caffeine came from store-bought coffee and tea. Among both children and adults combined, caffeine intakes declined from 175 mg/day (1999-2000) to 142 mg/day (2011-2012), largely driven by a drop in caffeine from soda (41 mg/day to 21 mg/day). Store-bought coffee and tea remain principal drivers of caffeine intake in the US. Sodas and energy drinks make minor contributions to overall caffeine intakes.

  5. Sources of Caffeine in Diets of US Children and Adults: Trends by Beverage Type and Purchase Location

    Directory of Open Access Journals (Sweden)

    Adam Drewnowski

    2016-03-01

    Full Text Available New sources of caffeine, besides coffee and tea, have been introduced into the US food supply. Data on caffeine consumption age and purchase location can help guide public health policy. National Health and Nutrition Examination Surveys (NHANES were used to estimate population-level caffeine intakes, using data from 24-h dietary recall. First, caffeine intakes by age-group and beverage type were estimated using the most recent 2011–2012 data (n = 7456. Second, fourteen years trends in caffeine consumption, overall and by beverage type, were evaluated for adults and children. Trend analyses were conducted by age groups. Last, trends in caffeine intakes by purchase location and beverage type were estimated. In 2011–2012, children aged four to eight years consumed the least caffeine (15 mg/day, and adults aged 51–70 years consumed the most (213 mg/day. The population mean (age ≥ four years was 135 mg/day, driven largely by coffee (90 mg/day, tea (25 mg/day, and soda (21 mg/day. For the 14–19 years and 20–34 years age-groups, energy drinks contributed 6 mg/day (9.9% and 5 mg/day (4.5%, respectively. The bulk of caffeine came from store-bought coffee and tea. Among both children and adults combined, caffeine intakes declined from 175 mg/day (1999–2000 to 142 mg/day (2011–2012, largely driven by a drop in caffeine from soda (41 mg/day to 21 mg/day. Store-bought coffee and tea remain principal drivers of caffeine intake in the US. Sodas and energy drinks make minor contributions to overall caffeine intakes.

  6. Automated phase picker and source location algorithm for local distances using a single three component seismic station

    International Nuclear Information System (INIS)

    Saari, J.

    1989-12-01

    The paper describes procedures for automatic location of local events by using single-site, three-component (3c) seismogram records. Epicentral distance is determined from the time difference between P- and S-onsets. For onset time estimates a special phase picker algorithm is introduced. Onset detection is accomplished by comparing short-term average with long-term average after multiplication of north, east and vertical components of recording. For epicentral distances up to 100 km, errors seldom exceed 5 km. The slowness vector, essentially the azimuth, is estimated independently by using the Christoffersson et al. (1988) 'polarization' technique, although a priori knowledge of the P-onset time gives the best results. Differences between 'true' and observed azimuths are generally less than 12 deg C. Practical examples are given by demonstrating the viability of the procedures for automated 3c seismogram analysis. The results obtained compare favourably with those achieved by a miniarray of three stations. (orig.)

  7. Radioimmunochemical characterization of hemoglobins Lepore and Kenya: unique antigenic determinants located on hybrid hemoglobins

    International Nuclear Information System (INIS)

    Garver, F.A.; Altay, G.; Baker, M.M.; Gravely, M.; Huisman, T.H.J.

    1978-01-01

    Antisera were produced in rabbits to the three known types of Lepore hemoglobins, which contain hybrid delta-β non-α-chains, and to hemoglobin Kenya, which has a hybrid γ-β non-α-chain. By using a sensitive radioimmunoassay technique, the absorbed antisera were shown to contain an antibody population that was specific for the hybrid hemoglobin and did not cross-react with normal hemoglobins. However, with the absorbed Lepore-specific antisera, the three known types of Lepore hemoglobins were antigenically indistinguishable from each other, suggesting that antibodies are not produced to the primary structural differences which define the three non-α-chains of the Lepore hemoglobins. These studies demonstrate that the non-α-subunits of hemoglobins Lepore and Kenya possess unique antigenic determinant sites, evidently resulting from an altered polypeptide conformation

  8. Systematic optimization of exterior measurement locations for the determination of interior magnetic field vector components in inaccessible regions

    Energy Technology Data Exchange (ETDEWEB)

    Nouri, N.; Plaster, B.

    2014-12-11

    An experiment may face the challenge of real-time determination of the magnetic field vector components present within some interior region of the experimental apparatus over which it is impossible to directly measure the field components during the operation of the experiment. As a solution to this problem, we propose a general concept which provides for a unique determination of the field components within such an interior region solely from exterior measurements at fixed discrete locations. The method is general and does not require the field to possess any type of symmetry. We describe our systematic approach for optimizing the locations of these exterior measurements which maximizes their sensitivity to successive terms in a multipole expansion of the field.

  9. Can we determine the filament chirality by the filament footpoint location or the barb-bearing?

    Science.gov (United States)

    Hao, Qi; Guo, Yang; Fang, Cheng; Chen, Peng-Fei; Cao, Wen-Da

    2016-01-01

    We attempt to propose a method for automatically detecting the solar filament chirality and barb bearing. We first introduce the concept of an unweighted undirected graph and adopt the Dijkstra shortest path algorithm to recognize the filament spine. Then, we use the polarity inversion line (PIL) shift method for measuring the polarities on both sides of the filament, and employ the connected components labeling method to identify the barbs and calculate the angle between each barb and the spine to determine the bearing of the barbs, i.e., left or right. We test the automatic detection method with Hα filtergrams from the Big Bear Solar Observatory (BBSO) Hα archive and magnetograms observed with the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO). Four filaments are automatically detected and illustrated to show the results. The barbs in different parts of a filament may have opposite bearings. The filaments in the southern hemisphere (northern hemisphere) mainly have left-bearing (right-bearing) barbs and positive (negative) magnetic helicity, respectively. The tested results demonstrate that our method is efficient and effective in detecting the bearing of filament barbs. It is demonstrated that the conventionally believed one-to-one correspondence between filament chirality and barb bearing is not valid. The correct detection of the filament axis chirality should be done by combining both imaging morphology and magnetic field observations.

  10. Can we determine the filament chirality by the filament footpoint location or the barb-bearing?

    International Nuclear Information System (INIS)

    Hao, Qi; Guo, Yang; Fang, Cheng; Chen, Peng-Fei; Cao, Wen-Da

    2016-01-01

    We attempt to propose a method for automatically detecting the solar filament chirality and barb bearing. We first introduce the concept of an unweighted undirected graph and adopt the Dijkstra shortest path algorithm to recognize the filament spine. Then, we use the polarity inversion line (PIL) shift method for measuring the polarities on both sides of the filament, and employ the connected components labeling method to identify the barbs and calculate the angle between each barb and the spine to determine the bearing of the barbs, i.e., left or right. We test the automatic detection method with Hα filtergrams from the Big Bear Solar Observatory (BBSO) Hα archive and magnetograms observed with the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO). Four filaments are automatically detected and illustrated to show the results. The barbs in different parts of a filament may have opposite bearings. The filaments in the southern hemisphere (northern hemisphere) mainly have left-bearing (right-bearing) barbs and positive (negative) magnetic helicity, respectively. The tested results demonstrate that our method is efficient and effective in detecting the bearing of filament barbs. It is demonstrated that the conventionally believed one-to-one correspondence between filament chirality and barb bearing is not valid. The correct detection of the filament axis chirality should be done by combining both imaging morphology and magnetic field observations. (paper)

  11. Labor Force – Main Determinant Of the Foreign Direct Investments Located in Romania

    Directory of Open Access Journals (Sweden)

    Aniela Raluca Danciu

    2015-03-01

    Full Text Available The foreign direct investments can be considered as one of the main factors that have sustained the evolution of the centralized former communist East-European economies into open competitive market systems. The East-European countries were the destination of some significant capital inflow because of some important features of each market as: development level of the infrastructure, labor force characteristics, market size and its future development possibilities, regulation level of the market, liberalization level of the prices, tax policies and technology absorption capability. When talking about Romania one of the main determinants of the foreign direct investments was the labor force, which attracted in the manufacturing industry to types of investors: cost oriented investors and quality oriented investors. The main goal of this research paper is to provide a clear description of the similarities and of the differences of the two investor types, at national and regional. Data used in this research were collected using a questionnaire and were further analyzed using the SPSS software.

  12. Determination of the 51Cr source strength at BNL

    International Nuclear Information System (INIS)

    Boger, J.; Hahn, R.L.; Chu, Y.Y.

    1995-11-01

    Neutron activation analysis (NAA) and γ-ray counting have been used to measure the activity of 24 samples removed from the GALLEX radioactive Cr neutrino source. In 9.86% of the disintegrations, 51 Cr decays with the emission of a 320-keV γ-ray. Counting this γ-ray provides a direct means to obtain the disintegration rates of the Cr samples. Based upon these disintegration rates, the authors obtain a strength of 63.1 ± 1.0 PBq for the entire Cr source. The Cr source activity has also been obtained through measuring the 51 V content of each sample by means of NAA. 51 V is the decay daughter for all decay modes of 51 Cr. Through neutron bombardment, radioactive 52 V is produced, which decays with the emission of a 1,434-keV γ-ray. By counting this γ-ray from NAA, they obtain a disintegration rate of 62.1 ± 1.0 PBq for the entire source. These values are consistent with all other measurements of the source strength done at other GALLEX Laboratories

  13. Determination of disintegration rates of a 60Co point source and volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The disintegration rates of 60 Co as a point source (<2 mm in diameter on a thin plastic disc) and volume sources (10-100 mL solutions in a polyethylene bottle) are determined by the sum-peak method. The sum-peak formula gives the exact disintegration rate for the point source at different positions from the detector. However, increasing the volume of the solution results in enlarged deviations from the true disintegration rate. Extended sources must be treated as an amalgam of many point sources. (author)

  14. A methodology to determine the power performance of wave energy converters at a particular coastal location

    International Nuclear Information System (INIS)

    Carballo, R.; Iglesias, G.

    2012-01-01

    Highlights: ► We develop a method to accurately compute the power output of a WEC at a site. ► The analysis of the wave resource is integrated seamlessly with the WEC efficiency. ► The intra-annual variability of the resource is considered. ► The method is illustrated with a case study: a WEC projected to be built in Spain. - Abstract: The assessment of the power performance of a wave energy converter (WEC) at a given site involves two tasks: (i) the characterisation of the wave resource at the site in question, and (ii) the computation of its power performance. These tasks are generally seen as disconnected, and tackled as such; they are, however, deeply interrelated – so much so that they should be treated as two phases of the same procedure. Indeed, beyond the characterisation of the wave resource of a certain area lies a crucial question: how much power would a WEC installed in that area output to the network? This work has two main objectives. First, to develop a methodology that integrates both tasks seamlessly and guarantees the accurate computation of the power performance of a WEC installed at a site of interest; it involves a large dataset of deepwater records and the implementation of a high-resolution, nested spectral model, which is used to propagate 95% of the total offshore wave energy to the WEC site. The second objective is to illustrate this methodology with a case study: an Oscillating Water Column (OWC) projected to be constructed at the breakwater of A Guarda (NW Spain). It is found that the approach presented allows to accurately determine the power that the WEC will output to the network, and that this power exhibits a significant monthly variability, so an estimate of the energy production based on mean annual values may be misleading.

  15. Determination of the properties of magnetic turbulence in radio sources

    International Nuclear Information System (INIS)

    Spangler, S.R.

    1983-01-01

    We have considered the transport of polarized synchrotron radiation in a source possessing a highly irregular magnetic field, as proposed by Laing. The transport equation has been solved in a special case, relating the observable correlation functions in the Stokes parameters Q and U to the correlation functions of magnetic field and plasma density in the source. A rough application of our results to observations of the radio galaxy 3C 166 indicates that the turbulent scale length may be a few percent of the lobe size

  16. Determining the Location of the Snowline in an Externally-Photoevaporated Solar Nebula

    Science.gov (United States)

    Kalyaan, Anusha; Desch, Steven

    2015-11-01

    The water snowline in the solar nebula, the point beyond which water exists abundantly as ice, is often taken to lie at 2.7 AU from the Sun, where temperatures are ~170 K, the sublimation point of water [1,2]. While superficially consistent with the spatial distribution of (wet) C-type and (dry) S-type asteroids between 2-3AU [3], most disk models place the snowline closer to ~1AU [4]. Aside from temperature, radial transport and outward diffusion of water vapor, and the inward drift of ices also determine where the snowline is [5,6]. Over many Myr, a steady cycling of water inward and outward across the T=170 K line balance out, with an enhanced ice abundance outside creating the ‘snowline’[2]. But external effects like photoevaporation of the nebula by nearby massive stars can potentially shift this balance, lead to net outward water vapor transport from the inner nebula [7,8], pushing the snowline beyond T=170 K, thus giving rise to water-poor planets.To test this hypothesis, we have first built a 1+1D protoplanetary disk evolution model, incorporating viscosity due to the magnetorotational instability with a non-uniform turbulent viscosity α across disk radius r, ionization equilibrium with dust, and external photoevaporation [8]. Our simulation results suggest that the structure of the photoevaporated solar nebula with a non-uniform α(r) was more complex than previously thought, with the following features: (i) very steep Σ profile (Σ(r)=Σ0 r-p, where slope p = 3-5, > pMMSN=1.5) due to the varying α(r), that is further steepened by the effect of dust and photoevaporation, and (ii) transition radius (where net disk mass flow changes from inward flow to outward) that is present very close to the star (~3AU). We apply these new results to study the distribution of water in the solar nebula. References: [1] Hayashi, C., (1981) PThP.Supp. 70, 35-53 [2] Stevenson,D., & Lunine,J., (1988) Icarus 75, 146-155 [3] Gradie, J., & Tedesco, E.,(1982) Science 216

  17. Experimental facility for determining plasma characteristics in ion sources

    International Nuclear Information System (INIS)

    Abroyan, M.A.; Kagan, Yu.M.; Kolokolov, N.B.; Lavrov, B.P.

    A facility for optical and electrical measurements of the plasma parameters in the arc plasma ion sources is described. The potentialities of the system are demonstrated on the basis of the electron concentration, the electron energy distribution function, and the radial population distribution of the excited states of hydrogen atoms in the arc plasma of the duoplasmatron. (U.S.)

  18. Determination of source terms in a degenerate parabolic equation

    International Nuclear Information System (INIS)

    Cannarsa, P; Tort, J; Yamamoto, M

    2010-01-01

    In this paper, we prove Lipschitz stability results for inverse source problems relative to parabolic equations. We use the method introduced by Imanuvilov and Yamamoto in 1998 based on Carleman estimates. What is new here is that we study a class of one-dimensional degenerate parabolic equations. In our model, the diffusion coefficient vanishes at one extreme point of the domain. Instead of the classical Carleman estimates obtained by Fursikov and Imanuvilov for non degenerate equations, we use and extend some recent Carleman estimates for degenerate equations obtained by Cannarsa, Martinez and Vancostenoble. Finally, we obtain Lipschitz stability results in inverse source problems for our class of degenerate parabolic equations both in the case of a boundary observation and in the case of a locally distributed observation

  19. Effects of methods of attenuation correction on source parameter determination

    Science.gov (United States)

    Sonley, Eleanor; Abercrombie, Rachel E.

    We quantify the effects of using different approaches to model individual earthquake spectra. Applying different approaches can introduce significant variability in the calculated source parameters, even when applied to the same data. To compare large and small earthquake source parameters, the results of multiple studies need to be combined to extend the magnitude range, but the variability introduced by the different approaches hampers the outcome. When studies are combined, there is large uncertainty and large scatter and some systematic differences have been neglected. We model individual earthquake spectra from repeating earthquakes (M˜2) at Parkfield, CA, recorded by a borehole network. We focus on the effects of trade-offs between attenuation (Q) and corner frequency in spectral fitting and the effect of the model shape at the corner frequency on radiated energy. The trade-off between attenuation and corner frequency can increase radiated energy by up to 400% and seismic moment by up to 100%.

  20. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  1. Determining Source Attenuation History to Support Closure by Natural Attenuation

    Science.gov (United States)

    2013-11-01

    restrictive and not very representative • Passes “ eyeball test” for style Source history captures the style of measured field data: Ratio of... eyeball test.” For all of the cases, the simulated and measured soil data often appeared very similar in style throughout the entire low permeability...representative metric confirmed that the modeling results demonstrated reasonable accuracy, which matches the expectations based on simple “ eyeball

  2. Cell source determines the immunological impact of biomimetic nanoparticles.

    Science.gov (United States)

    Evangelopoulos, Michael; Parodi, Alessandro; Martinez, Jonathan O; Yazdi, Iman K; Cevenini, Armando; van de Ven, Anne L; Quattrocchi, Nicoletta; Boada, Christian; Taghipour, Nima; Corbo, Claudia; Brown, Brandon S; Scaria, Shilpa; Liu, Xuewu; Ferrari, Mauro; Tasciotti, Ennio

    2016-03-01

    Recently, engineering the surface of nanotherapeutics with biologics to provide them with superior biocompatibility and targeting towards pathological tissues has gained significant popularity. Although the functionalization of drug delivery vectors with cellular materials has been shown to provide synthetic particles with unique biological properties, these approaches may have undesirable immunological repercussions upon systemic administration. Herein, we comparatively analyzed unmodified multistage nanovectors and particles functionalized with murine and human leukocyte cellular membrane, dubbed Leukolike Vectors (LLV), and the immunological effects that may arise in vitro and in vivo. Previously, LLV demonstrated an avoidance of opsonization and phagocytosis, in addition to superior targeting of inflammation and prolonged circulation. In this work, we performed a comprehensive evaluation of the importance of the source of cellular membrane in increasing their systemic tolerance and minimizing an inflammatory response. Time-lapse microscopy revealed LLV developed using a cellular coating derived from a murine (i.e., syngeneic) source resulted in an active avoidance of uptake by macrophage cells. Additionally, LLV composed of a murine membrane were found to have decreased uptake in the liver with no significant effect on hepatic function. As biomimicry continues to develop, this work demonstrates the necessity to consider the source of biological material in the development of future drug delivery carriers. Copyright © 2015. Published by Elsevier Ltd.

  3. Determination of Destress Blasting Effectiveness Using Seismic Source Parameters

    Science.gov (United States)

    Wojtecki, Łukasz; Mendecki, Maciej J.; Zuberek, Wacaław M.

    2017-12-01

    Underground mining of coal seams in the Upper Silesian Coal Basin is currently performed under difficult geological and mining conditions. The mining depth, dislocations (faults and folds) and mining remnants are responsible for rockburst hazard in the highest degree. This hazard can be minimized by using active rockburst prevention, where destress blastings play an important role. Destress blastings in coal seams aim to destress the local stress concentrations. These blastings are usually performed from the longwall face to decrease the stress level ahead of the longwall. An accurate estimation of active rockburst prevention effectiveness is important during mining under disadvantageous geological and mining conditions, which affect the risk of rockburst. Seismic source parameters characterize the focus of tremor, which may be useful in estimating the destress blasting effects. Investigated destress blastings were performed in coal seam no. 507 during its longwall mining in one of the coal mines in the Upper Silesian Coal Basin under difficult geological and mining conditions. The seismic source parameters of the provoked tremors were calculated. The presented preliminary investigations enable a rapid estimation of the destress blasting effectiveness using seismic source parameters, but further analysis in other geological and mining conditions with other blasting parameters is required.

  4. Determination of Effective Criteria for location Selection of WPC Plants from agricultural residues in Iran by AHP Technique

    Directory of Open Access Journals (Sweden)

    hasan alizadeh

    2017-02-01

    Full Text Available This study was aimed at determining the effective criteria for location selection of WPC Plants from agricultural residues in Iran. For this purpose, after review and studies papers and books, Six criteria" products and materials, regulations, technical and human, economic, infrastructure and environmental and also 30 sub-criteria were identified. The priority rates of these criteria and sub-criteria were evaluated by AHP technique. The results indicated that among 30 effective sub-criteria in location selection of the WPC plants from agricultural residues, amount of wastes supply (0.087, continuity of wastes supply, cost of wastes supply, amount of sales and export, granted facilities and less Hazards for the environment and forest had the highest priorities, which were rated as 0.071, 0.067, 0.065, 0.064 and 0.062 respectively.

  5. Source contributions to PM{sub 2.5} and PM{sub 10} at an urban background and a street location

    Energy Technology Data Exchange (ETDEWEB)

    Keuken, M.; Voogt, M.; Moerman, M. [TNO, Utrecht (Netherlands); Blom, M.; Weijers, E.P. [Energy research Centre of the Netherlands ECN, Petten (Netherlands); Roeckmann, T.; Dusek, U. [Institute for Marine and Atmospheric Research IMAU, Utrecht (Netherlands)

    2013-06-15

    The contribution of regional, urban and traffic sources to PM{sub 2.5} and PM{sub 10} in an urban area was investigated in this study. The chemical composition of PM{sub 2.5} and PM{sub 10} was measured over a year at a street location and up- and down-wind of the city of Rotterdam, Netherlands. The {sup 14}C content in EC and OC concentrations was also determined, to distinguish the contribution from 'modern' carbon (e.g., biogenic emissions, biomass burning and wildfires) and fossil fuel combustion. It was concluded that the urban background of PM{sub 2.5} and PM{sub 10} is dominated by the regional background, and that primary and secondary PM emission by urban sources contribute less than 15%. The {sup 14}C analysis revealed that 70% of OC originates from modern carbon and 30% from fossil fuel combustion. The corresponding percentages for EC are, respectively 17% and 83%. It is concluded that in particular the urban population living in street canyons with intense road traffic has potential health risks. This is due to exposure to elevated concentrations of a factor two for EC from exhaust emissions in PM{sub 2.5} and a factor 2-3 for heavy metals from brake and tyre wear, and re-suspended road dust in PM{sub 10}. It follows that local air quality management may focus on local measures to street canyons with intense road traffic.

  6. Consideration of Fugitive Emissions in Major Source Determinations

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  7. Northeast Hub Partners and United Salts Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  8. Single Source Determination for Coors/TriGen

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  9. Determination of illuminants representing typical white light emitting diodes sources

    DEFF Research Database (Denmark)

    Jost, S.; Ngo, M.; Ferrero, A.

    2017-01-01

    is to develop LED-based illuminants that describe typical white LED products based on their Spectral Power Distributions (SPDs). Some of these new illuminants will be recommended in the update of the CIE publication 15 on colorimetry with the other typical illuminants, and among them, some could be used......Solid-state lighting (SSL) products are already in use by consumers and are rapidly gaining the lighting market. Especially, white Light Emitting Diode (LED) sources are replacing banned incandescent lamps and other lighting technologies in most general lighting applications. The aim of this work...... to complement the CIE standard illuminant A for calibration use in photometry....

  10. Determining the shape of the universe using discrete sources

    International Nuclear Information System (INIS)

    Gomero, G I

    2003-01-01

    Suppose we have identified three clusters of galaxies as being topological copies of the same object. How does this information constrain the possible models for the shape of our universe? It is shown here that, if our universe has flat spatial sections, these multiple images can be accommodated within any of the six classes of compact orientable three-dimensional flat space forms. Moreover, the discovery of two more triples of multiple images in the neighbourhood of the first one would allow the determination of the topology of the universe, and in most cases the determination of its size

  11. Determining Sediment Sources in the Anacostia River Watershed

    Science.gov (United States)

    Devereux, O. H.; Needelman, B. A.; Prestegaard, K. L.; Gellis, A. C.; Ritchie, J. C.

    2005-12-01

    Suspended sediment is a water-quality problem in the Chesapeake Bay. This project is designed to identify sediment sources in an urban watershed, the Northeast Branch of the Anacostia River (in Washington, D.C. and Maryland - drainage area = 188.5 km2), which delivers sediment directly to the Bay. This watershed spans two physiographic regions - the Piedmont and Coastal Plain. Bank sediment and suspended-sediment deposits were characterized using the following techniques: radionuclide (Cs-137) analysis by gamma ray spectrometry, trace-element analysis by ICP-MS, clay mineralogy by XRD, and particle-size analysis by use of a laser particle-size analyzer. Sampling of bank and suspended sediment was designed to: a) characterize tributary inputs from both Piedmont and Coastal Plain sources, and b) differentiate tributary inputs from bank erosion along the main stem of the Northeast Branch. Thirteen sample sites were chosen that represent tributary source areas of each physiographic region and the main stem where mixing occurs. Surface samples of the banks were compared to overbank deposits from a ten year storm (a proxy for the suspended sediments). Fingerprint components are selected from these data. Cesium-137 concentrations were analyzed for bank and overbank deposits for each physiographic region. No clear differences were seen between the two physiographic regions. Significant differences were observed between upland tributaries and the main stem of the Anacostia River. The average activity of Cs-137 for the tributaries was 5.4 bq/kg and the average for the main stem was 1.1 bq/kg. This suggests that there is significant erosion and storage of sediment in the tributaries. The low activity from Cs-137 in the main stem suggests a lack of storage of sediment along the main stem of the river. For the trace-element data, we focused on elements that showed significant variation among the sites. For the bank sediment, these elements include: Sr, V, Y, Ce, and Nd. For the

  12. Lattice location of Tm in Si and Ge determined from ion channeling followed by Monte Carlo simulations

    International Nuclear Information System (INIS)

    Yamamoto, Y.; Wakaiki, M.; Ikeda, A.; Kido, Y.

    1999-01-01

    The lattice location of Tm implanted into Si(1 0 0) and Ge(1 1 1) with energy of 180 keV was determined precisely by ion channeling followed by Monte Carlo simulations of ion trajectories. The implantations were performed at 550 deg. C with a dose of 5 x 10 14 ions/cm 2 . In the case of Tm in Si, 25 at.% and 50 at.% of Tm are located in the tetrahedral interstitial site and in the random site, respectively and the rest takes the substitutional position. The assumption of the Gaussian distribution centered at the exact tetrahedral site with a standard deviation of 0.2 Angstroms reproduced the azimuth angular-scan spectrum around the [1 1 0] axis. However, the observed angular spectrum is significantly broader than the simulated one. This is probably due to the fact that there exist slightly different Tm lattice sites from the exact tetrahedral position. For Ge(1 1 1) substrates, 25 at.% of Tm occupied the tetrahedral interstitial site and the rest was located randomly

  13. A method to determine the detector locations of the cone-beam projection of the balls’ centers

    International Nuclear Information System (INIS)

    Deng, Lin; Xi, Xiaoqi; Li, Lei; Han, Yu; Yan, Bin

    2015-01-01

    In geometric calibration of cone-beam computed tomography (CBCT), sphere-like objects such as balls are widely imaged, the positioning information of which is obtained to determine the unknown geometric parameters. In this process, the accuracy of the detector location of CB projection of the center of the ball, which we call the center projection, is very important, since geometric calibration is sensitive to errors in the positioning information. Currently in almost all the geometric calibration using balls, the center projection is invariably estimated by the center of the support of the projection or the centroid of the intensity values inside the support approximately. Clackdoyle’s work indicates that the center projection is not always at the center of the support or the centroid of the intensity values inside, and has given a quantitative analysis of the maximum errors in evaluating the center projection by the centroid. In this paper, an exact method is proposed to calculate the center projection, utilizing both the detector location of the ellipse center and the two axis lengths of the ellipse. Numerical simulation results have demonstrated the precision and the robustness of the proposed method. Finally there are some comments on this work with non-uniform density balls, as well as the effect by the error occurred in the evaluation for the location of the orthogonal projection of the cone vertex onto the detector. (paper)

  14. The Dietary Composition and Source of Macronutrients Determine Obesity Development

    DEFF Research Database (Denmark)

    Myrmel, Lene Secher

    The drastic worldwide increase in obesity during the last decades is accompanied with several different health disorders. The underlying mechanisms for this escalation is not clear, but certain alterations in the dietary macronutrient composition are suggested to be of importance. In addition...... fat and marine oils. To further investigate the importance of the macronutrient composition on obesity development, we have performed a series of mice experiments. Our results demonstrate that both the amount and source of macronutrients influence obesity development and related disorders. The anti...... to attenuate obesity development. The gut microbiota is less affected by alterations in protein:carbohydrate ratio and adiposity, but is altered in response to an elevated fat intake. The macronutrient composition is able to affect obesity development through direct influence on energy consuming metabolic...

  15. Determining the sources of calcium for migratory songbirds using stable strontium isotopes.

    Science.gov (United States)

    Blum, Joel D; Taliaferro, E Hank; Holmes, Richard T

    2001-02-01

    We investigated natural variations in the stable isotopic composition of strontium (a surrogate for calcium) in the bones of a single species of breeding migratory songbird, as well as in their eggshells, egg contents, and food sources. We use this information to determine the sources of calcium to these migratory songbirds and their offspring. Samples were collected from two locations in the northeastern USA (Hubbard Brook, NH, and Downer Forest, VT.) that differed in soil geochemistry. The mean 87 Sr/ 86 Sr ratios of food items (caterpillars and snails), eggshells, and egg contents were indistinguishable within each site, but significantly different between the two sites. Mean 87 Sr/ 86 Sr ratios for the bones of adult females were significantly different between the two sites, but values were significantly lower than those of food items and eggshells at each site. Two of four adult individuals studied at each site had 87 Sr/ 86 Sr ratios lower than the entire range of values for local food sources. Mixing calculations indicate that up to 60% of skeletal strontium and calcium was derived from foods consumed in the winter grounds where lower 87 Sr/ 86 Sr ratios predominate. At each study site, the 87 Sr/ 86 Sr ratio of eggshells differed significantly between clutches, but the mean clutch 87 Sr/ 86 Sr ratios were unrelated to the skeletal 87 Sr/ 86 Sr ratio of the laying adult. These findings suggest that strontium (and hence calcium) for eggshell production in this species is derived predominantly from local food sources in breeding areas. Thus, reductions in available calcium in northern temperate ecosystems due to the influences of acid deposition could be potentially harmful to this and other species of migratory bird.

  16. Determination, source identification and GIS mapping for nitrate concentration in ground water from Bara aquifer

    International Nuclear Information System (INIS)

    Elfaki Taha, G. M. E.

    2010-09-01

    The study was carried-out determine the level of nitrate concentration in well water from Bara aquifer in North Kordofan State. The analysis was conducted for 69 wells from different villages within Bara basin. Physical characteristics were measured including pH, electrical conductivity and dissolved oxygen. Spectrophotometric analysis was used to determine nitrate, nitrite and ammonia. Chloride and hardness were determined telemetrically and flame photometer was used for major elements namely sodium and potassium, whereas atomic absorption spectroscopy was used for trace elements namely iron, manganese, zinc and copper. Results revealed that nitrate concentration range from 9.68 to 891 mg/1 in sampled wells with 81% exceeding the maximum permissible limits set for drinking water by WHO and SSMO. Animal waste and organic soil nitrogen were found to be the sources of nitrate in these wells as indicated by 15 N%. Majority of wells with high nitrate are located in the north and the north-east part of the study area as shown by GIS predictive map. On the average, the concentrations of sodium, potassium, calcium, magnesium, iron, manganese, zinc and copper were found to be within WHO limits for drinking water. (Author)

  17. ANL calculational methodologies for determining spent nuclear fuel source term

    International Nuclear Information System (INIS)

    McKnight, R. D.

    2000-01-01

    Over the last decade Argonne National Laboratory has developed reactor depletion methods and models to determine radionuclide inventories of irradiated EBR-II fuels. Predicted masses based on these calculational methodologies have been validated using available data from destructive measurements--first from measurements of lead EBR-II experimental test assemblies and later using data obtained from processing irradiated EBR-II fuel assemblies in the Fuel Conditioning Facility. Details of these generic methodologies are described herein. Validation results demonstrate these methods meet the FCF operations and material control and accountancy requirements

  18. Dynamic determination of equivalent CT source models for personalized dosimetry

    Directory of Open Access Journals (Sweden)

    Rosendahl Stephan

    2017-09-01

    Full Text Available With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.

  19. Determination of Magnitude and Location of Earthquakes With Only Five Seconds of a Three Component Broadband Sensor Signal Located Near Bogota, Colombia Using Support Vector Machines

    Science.gov (United States)

    Ochoa Gutierrez, L. H.; Vargas Jiménez, C. A.; Niño Vasquez, L. F., Sr.

    2017-12-01

    Early warning generation for earthquakes that occur near the city of Bogotá-Colombia is extremely important. Using the information of a broadband and three component station, property of the Servicio Geológico Colombiano (SGC), called El Rosal, which is located very near the city, we developed a model based on support vector machines techniques (SVM), with a standardized polynomial kernel, using as descriptors or input data, seismic signal features, complemented by the hipocentral parameters calculated for each one of the reported events. The model was trained and evaluated by cross correlation and was used to predict, with only five seconds of signal, the magnitude and location of a seismic event. With the proposed model we calculated local magnitude with an accuracy of 0.19 units of magnitude, epicentral distance with an accuracy of about 11 k, depth with a precision of approximately 40 km and the azimuth of arrival with a precision of 45°. This research made a significant contribution for early warning generation for the country, in particular for the city of Bogotá. These models will be implemented in the future in the "Red Sismológica de la Sabana de Bogotá y sus Alrededores (RSSB)" which belongs to the Universidad Nacional de Colombia.

  20. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  1. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  2. Determining the sources of fine-grained sediment using the Sediment Source Assessment Tool (Sed_SAT)

    Science.gov (United States)

    Gorman Sanisaca, Lillian E.; Gellis, Allen C.; Lorenz, David L.

    2017-07-27

    A sound understanding of sources contributing to instream sediment flux in a watershed is important when developing total maximum daily load (TMDL) management strategies designed to reduce suspended sediment in streams. Sediment fingerprinting and sediment budget approaches are two techniques that, when used jointly, can qualify and quantify the major sources of sediment in a given watershed. The sediment fingerprinting approach uses trace element concentrations from samples in known potential source areas to determine a clear signature of each potential source. A mixing model is then used to determine the relative source contribution to the target suspended sediment samples.The computational steps required to apportion sediment for each target sample are quite involved and time intensive, a problem the Sediment Source Assessment Tool (Sed_SAT) addresses. Sed_SAT is a user-friendly statistical model that guides the user through the necessary steps in order to quantify the relative contributions of sediment sources in a given watershed. The model is written using the statistical software R (R Core Team, 2016b) and utilizes Microsoft Access® as a user interface but requires no prior knowledge of R or Microsoft Access® to successfully run the model successfully. Sed_SAT identifies outliers, corrects for differences in size and organic content in the source samples relative to the target samples, evaluates the conservative behavior of tracers used in fingerprinting by applying a “Bracket Test,” identifies tracers with the highest discriminatory power, and provides robust error analysis through a Monte Carlo simulation following the mixing model. Quantifying sediment source contributions using the sediment fingerprinting approach provides local, State, and Federal land management agencies with important information needed to implement effective strategies to reduce sediment. Sed_SAT is designed to assist these agencies in applying the sediment fingerprinting

  3. Effects of source and receiver locations in predicting room transfer functions by a phased beam tracing method

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Ih, Jeong-Guon

    2012-01-01

    The accuracy of a phased beam tracing method in predicting transfer functions is investigated with a special focus on the positions of the source and receiver. Simulated transfer functions for various source-receiver pairs using the phased beam tracing method were compared with analytical Green’s...

  4. Influence of the vibration source location on the modes of jet disintegration in the priller and on monodispersity of the finished product

    OpenAIRE

    Skydanenko, Maksym; Kononenko, Mykola; Kurdes, Yuliia

    2017-01-01

    Influence of the vibration source location on the modes of liquid jets disintegration and obtaining monodisperse droplets and granules of the finished product is theoretically grounded and experimentally confirmed. The experiment was conducted on an experimental stand of industrial granulation equipment.

  5. Real-time determination of magnetic island location for neoclassical tearing mode control in DIII-D

    International Nuclear Information System (INIS)

    Park, Y S; Welander, A S

    2006-01-01

    Accurate measurement of island location is crucial for efficient suppression of the neoclassical tearing mode by electron cyclotron current drive (ECCD). In the control system on DIII-D the contour of the resonant q-surface is measured in real time based on real-time magnetohydrodynamic reconstructions, EFITs, that include motional Stark effect measurements of pitch angle in the analysis. A new method for determination of the radial position of the q-surface using a 40 channel electron cyclotron emission radiometer has been developed. This method analyses localized temperature fluctuations caused by motion of the island and can be used by the plasma control system as a complementary measurement of the radial position of the q-surface contour for faster and more accurate alignment of the ECCD

  6. Determination of a source term for a time fractional diffusion equation with an integral type over-determining condition

    Directory of Open Access Journals (Sweden)

    Timurkhan S. Aleroev

    2013-12-01

    Full Text Available We consider a linear heat equation involving a fractional derivative in time, with a nonlocal boundary condition. We determine a source term independent of the space variable, and the temperature distribution for a problem with an over-determining condition of integral type. We prove the existence and uniqueness of the solution, and its continuous dependence on the data.

  7. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    International Nuclear Information System (INIS)

    Joenemalm, C.; Malen, K

    1966-10-01

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources

  8. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Joenemalm, C; Malen, K

    1966-10-15

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources.

  9. SOURCE AND PATHWAY DETERMINATION FOR BERYLLIUM FOUND IN BECHTEL NEVADA NORTH LAS VEGAS FACILITIES

    Energy Technology Data Exchange (ETDEWEB)

    BECHTEL NEVADA

    2004-07-01

    In response to the report ''Investigation of Beryllium Exposure Cases Discovered at the North Las Vegas Facility of the National Nuclear Security Administration'', published by the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA) in August 2003, Bechtel Nevada (BN) President and General Manager Dr. F. A. Tarantino appointed the Beryllium Investigation & Assessment Team (BIAT) to identify both the source and pathway for the beryllium found in the North Las Vegas (NLV) B-Complex. From September 8 to December 18, 2003, the BIAT investigated the pathway for beryllium and determined that a number of locations existed at the Nevada Test Site (NTS) which could have contained sufficient quantities of beryllium to result in contamination if transported. Operations performed in the B-1 Building as a result of characterization activities at the Engine Maintenance, Assembly, and Disassembly (EMAD); Reactor Maintenance, Assembly, and Disassembly (RMAD); Test Cells A and C; and the Central Support Facility in Area 25 had the greatest opportunity for transport of beryllium. Investigative monitoring and sampling was performed at these sites with subsequent transport of sample materials, equipment, and personnel from the NTS to the B-1 Building. The timeline established by the BIAT for potential transport of the beryllium contamination into the B-1 Building was from September 1997 through November 2002. Based on results of recently completed swipe sampling, no evidence of transport of beryllium from test areas has been confirmed. Results less than the DOE beryllium action level of 0.2 ???g/100 cm2 were noted for work support facilities located in Area 25. All of the identified sites in Area 25 worked within the B-1 tenant's residency timeline have been remediated. Legacy contaminants have either been disposed of or capped with clean borrow material. As such, no current opportunity exists for release or spread of beryllium

  10. New sites of Australasian microtektites in the central Indian Ocean: Implications for the location and size of source crater

    Digital Repository Service at National Institute of Oceanography (India)

    ShyamPrasad, M.; Mahale, V.P.; Kodagali, V.N.

    Fifteen new Australasian microtektite sites have been identified along a transect roughly N-S in the central Indian Ocean. These locations, in addition to the existing 46 sites, total to 61 microtektite sites in the oceans. We carried out regression...

  11. Determination of boron in water solution by an indirect neutron activation technique from a 241Am/Be source

    International Nuclear Information System (INIS)

    Sales, H.B.

    1981-08-01

    Boron content in water solutions has been analysed by Indirect Activation Technique a twin 241 Am/Be neutron source with a source strength of 9x10 6 n/seg. The boron concentration was inferred from the measurement of the activity induced in a vanadium flux monitor. The vanadium rod was located inside the boron solution in a standart geometrical set up with respect to the neutron source. Boron concentrations in the range of 100 to 1000 ppm were determined with an overall accuracy of about 2% during a total analysis time of about 20 minutes. Eventhough the analysis is not selective for boron yet due the rapid, simple and precise nature, it is proposed for the analysis of boron in the primary coolant circuit of Nuclear Power Plants of PWR type. (Author) [pt

  12. Area Median Income and Metropolitan Versus Nonmetropolitan Location of Care for Acute Coronary Syndromes: A Complex Interaction of Social Determinants.

    Science.gov (United States)

    Fabreau, Gabriel E; Leung, Alexander A; Southern, Danielle A; James, Matthew T; Knudtson, Merrill L; Ghali, William A; Ayanian, John Z

    2016-02-23

    Metropolitan versus nonmetropolitan status and area median income may independently affect care for and outcomes of acute coronary syndromes. We sought to determine whether location of care modifies the association among area income, receipt of cardiac catheterization, and mortality following an acute coronary syndrome in a universal health care system. We studied a cohort of 14 012 acute coronary syndrome patients admitted to cardiology services between April 18, 2004, and December 31, 2011, in southern Alberta, Canada. We used multivariable logistic regression to determine the odds of cardiac catheterization within 1 day and 7 days of admission and the odds of 30-day and 1-year mortality according to area median household income quintile for patients presenting at metropolitan and nonmetropolitan hospitals. In models adjusting for area income, patients who presented at nonmetropolitan facilities had lower adjusted odds of receiving cardiac catheterization within 1 day of admission (odds ratio 0.22, 95% CI 0.11-0.46, Pcommunities. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  13. Accuracy Assessment in Determining the Location of Corners of Building Structures Using a Combination of Various Measurement Methods

    Science.gov (United States)

    Krzyżek, Robert; Przewięźlikowska, Anna

    2017-12-01

    When surveys of corners of building structures are carried out, surveyors frequently use a compilation of two surveying methods. The first one involves the determination of several corners with reference to a geodetic control using classical methods of surveying field details. The second method relates to the remaining corner points of a structure, which are determined in sequence from distance-distance intersection, using control linear values of the wall faces of the building, the so-called tie distances. This paper assesses the accuracy of coordinates of corner points of a building structure, determined using the method of distance-distance intersection, based on the corners which had previously been determined by the conducted surveys tied to a geodetic control. It should be noted, however, that such a method of surveying the corners of building structures from linear measures is based on the details of the first-order accuracy, while the regulations explicitly allow such measurement only for the details of the second- and third-order accuracy. Therefore, a question arises whether this legal provision is unfounded, or whether surveyors are acting not only against the applicable standards but also without due diligence while performing surveys? This study provides answers to the formulated problem. The main purpose of the study was to verify whether the actual method which is used in practice for surveying building structures allows to obtain the required accuracy of coordinates of the points being determined, or whether it should be strictly forbidden. The results of the conducted studies clearly demonstrate that the problem is definitely more complex. Eventually, however, it might be assumed that assessment of the accuracy in determining a location of corners of a building using a combination of two different surveying methods will meet the requirements of the regulation [MIA, 2011), subject to compliance with relevant baseline criteria, which have been

  14. Study of the precision of the gamma-ray burst source locations obtained with the Ulysses/PVO/CGRO network

    International Nuclear Information System (INIS)

    Cline, T.L.; Hurley, K.C.; Sommer, M.; Boer, M.; Niel, M.; Fishman, G.; Kouveliotou, C.; Meegan, C.; Paciesas, W.S.; Wilson, R.B.; Laros, J.G.; Klebesadel, R.W.

    1994-01-01

    The interplanetary gamma-ray burst network of the Ulysses, Compton-GRO, and Pioneer-Venus Orbiter missions has made source localizations with fractional-arc-minute precision for a number of events, and with auxiliary data, will provide useful annular-segment loci for many more. These studies have, thus far, yielded one possible counterpart, a Rosat x-ray association with the 92 May 1 burst. Similar to the historic 1978 November 19 burst/Einstein association, this possibility gives hope that network studies will provide a fundamental source clue for 'classical' bursts, just as a second supernova remnant in a network-defined source field has done for sgr events

  15. Bounds in the location-allocation problem

    DEFF Research Database (Denmark)

    Juel, Henrik

    1981-01-01

    Develops a family of stronger lower bounds on the objective function value of the location-allocation problem. Solution methods proposed to solve problems in location-allocation; Efforts to develop a more efficient bound solution procedure; Determination of the locations of the sources....

  16. Lippmann-Schwinger integral equation approach to the emission of radiation by sources located inside finite-sized dielectric structures

    DEFF Research Database (Denmark)

    Søndergaard, T.; Tromborg, Bjarne

    2002-01-01

    uses for analyzing the emission of light by sources in some antennas and optical components such as vertical cavity surface emitting lasers, microdisk lasers, and light emitting diodes. The methods also have prospective uses in quantum electrodynamics for studies of spontaneous emission from, e...

  17. The deposition of anal excretions by Melipona favosa foragers (Apidae: Meliponinae): behavioural observations concerning the location of food sources

    NARCIS (Netherlands)

    Aguilar, I. (Ingrid); Sommeijer, M.J.

    2000-01-01

    Melipona favosa consistently deposited anal excretions while foraging. Anal depositions were released more frequently and by more bees on artificial food sources at a greater distance from the nest. Our hypothesis that these deposits serve as scent marks is supported by experimental evidence

  18. Comparison of imaging modalities and source-localization algorithms in locating the induced activity during deep brain stimulation of the STN.

    Science.gov (United States)

    Mideksa, K G; Singh, A; Hoogenboom, N; Hellriegel, H; Krause, H; Schnitzler, A; Deuschl, G; Raethjen, J; Schmidt, G; Muthuraman, M

    2016-08-01

    One of the most commonly used therapy to treat patients with Parkinson's disease (PD) is deep brain stimulation (DBS) of the subthalamic nucleus (STN). Identifying the most optimal target area for the placement of the DBS electrodes have become one of the intensive research area. In this study, the first aim is to investigate the capabilities of different source-analysis techniques in detecting deep sources located at the sub-cortical level and validating it using the a-priori information about the location of the source, that is, the STN. Secondly, we aim at an investigation of whether EEG or MEG is best suited in mapping the DBS-induced brain activity. To do this, simultaneous EEG and MEG measurement were used to record the DBS-induced electromagnetic potentials and fields. The boundary-element method (BEM) have been used to solve the forward problem. The position of the DBS electrodes was then estimated using the dipole (moving, rotating, and fixed MUSIC), and current-density-reconstruction (CDR) (minimum-norm and sLORETA) approaches. The source-localization results from the dipole approaches demonstrated that the fixed MUSIC algorithm best localizes deep focal sources, whereas the moving dipole detects not only the region of interest but also neighboring regions that are affected by stimulating the STN. The results from the CDR approaches validated the capability of sLORETA in detecting the STN compared to minimum-norm. Moreover, the source-localization results using the EEG modality outperformed that of the MEG by locating the DBS-induced activity in the STN.

  19. The analytical determination of useful life and replacement intervals for equipment located in a non-harsh environment

    International Nuclear Information System (INIS)

    Glazman, J.S.; Ahluwalia, J.S.; Kneppel, D.S.; Harter, T.G.

    1985-01-01

    In order to establish useful life and replacement intervals for equipment located in a non-harsh environment, an analysis can be performed to show that either the thermal degradation of the equipment is insignificant over the life of the plant or that certain components must be replaced periodically. In these analyses it is necessary to calculate the thermal lives of the components based on their actual operating temperatures rather than at a single cabinet temperature. The Infrared Thermal Imaging Measurement System is a rapid technique for measuring the temperatures of all points on a board or cabinet side simultaneously. The infrared scan of the operating equipment is displayed on a monitor, analyzed and stored on videotape for future reference. This paper presents an approach to performing such an analysis using the example of a process analysis and display system. The equilibrium operating temperatures of the individual components in the above system were measured by the Infrared Thermal Imaging Measurement System and compared to a calculated maximum permitted service temperature determined by the Arrhenius methodology. Examples will be shown where it was possible to exempt entire assemblies from replacement by showing that no point on the assembly exceeds the calculated maximum permitted temperature

  20. Quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.

    1978-01-01

    Experimental details are given of the quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry. The effects of interfering species, and corrections that can be applied, are discussed. (U.K.)

  1. Determination of the power of multielement aerosol composition emission from distant industrial sources

    International Nuclear Information System (INIS)

    Popova, S.A.; Kutsenogij, K.P.; Chankina, O.V.

    2008-01-01

    The results from the monitoring of the temporal variability of the multielement composition of atmospheric aerosols are presented. They are used to determine the emission power of a series of elements from distant sources.

  2. Determination of activation level energy of nuclear isomers by calibration of microspectra of radioactive sources

    International Nuclear Information System (INIS)

    Veres, A.; Pavlicsek, I.

    1980-01-01

    Nuclear isomers with unknown activation level were irradiated by calibrated radioactive sources. The integral cross sections were calculated for different energies of the sources. The activation energy was given by values coinciding with each other within the limits of error. The method made the determination of the unknown level of 1180+-10 keV of 195 Pt nucleus possible. (author)

  3. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    International Nuclear Information System (INIS)

    Gaffney, Jeffrey

    2012-01-01

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  4. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Jeffrey [Univ. of Arkansas, Little Rock, AR (United States)

    2012-12-12

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  5. Determining the source region of auroral emissions in the prenoon oval using coordinated Polar BEAR UV-imaging and DMSP particle measurements

    Science.gov (United States)

    Newell, Patrick T.; Meng, CHING-I.; Huffman, Robert E.

    1992-01-01

    The Polar Beacon Experiment and Auroral Research (Polar BEAR) satellite included the capability for imaging the dayside auroral oval in full sunlight at several wavelengths. Particle observations from the DMSP F7 satellite during dayside auroral oval crossings are compared with approximately simultaneous Polar BEAR 1356-A images to determine the magnetospheric source region of the dayside auroral oval. The source region is determined from the DMSP particle data, according to recent work concerning the classification and identification of precipitation source regions. The close DMSP/Polar BEAR coincidences all occur when the former satellite is located between 0945 and 1000 MLT. Instances of auroral arcs mapping to each of several different regions, including the boundary plasma sheet, the low-latitude boundary layer, and the plasma mantle were found. It was determined that about half the time the most prominent auroral arcs are located at the interfaces between distinct plasma regions, at least at the local time studied here.

  6. Rate Proposal for Remuneration of Air Pollutants Emissions From Stationary Sources Located in Bogota D.C.

    Directory of Open Access Journals (Sweden)

    Gabriel Herrera Torres

    2011-04-01

    Full Text Available The objective of this project is to develop a methodological proposal for the establishment of the retributive rate for the direct use of the atmosphere as the receptor of pollutant emissions that come from stationary resources on Bogotá D.C. By means of the emissions from stationary sources inventory and the air quality analysis, the pollutant that are emitted by the industries and the ones that are regulated by the network observations of the were identified selecting the particulated matter (PM10, sulfur oxides (SOx, and nitrogen oxides (NOx as the atmospheric pollutants that should be the object of payment in the retributive rate. Besides the selection of the pollutants that should be in the payment, the analysis of the retributive rate structure was made witch was based on the description or four key elements the generated fact, the tax base, the passive subject, and the fee of the rate. taking into account the social costs which are related to the investment being made by the district for the treatment of patients that present acute respiratory diseases ERA´s, associated and the costs of program control and monitoring of the air quality in Bogotá, the tariffs of the payment of the retributive rate were redefined in 281 $/Kg for the PM10, 2816 $/kg for the SOX and 2866 $/kg for NOX. Finally a new model of the payment was established, which is the result of the multiplication of the respective tariff for each of the pollutants that were selected as object of payment, expressed in ($/kg times, the charge of the pollutants emitted by the source expressed in (kg/ day.times the total number of days of the operation of the source emissions in a year.

  7. Controls of tectonics and sediment source locations on along-strike variations in transgressive deposits on the northern California margin

    Science.gov (United States)

    Spinelli, G.A.; Field, M.E.

    2003-01-01

    We identify two surfaces in the shallow subsurface on the Eel River margin offshore northern California, a lowstand erosion surface, likely formed during the last glacial maximum, and an overlying surface likely formed during the most recent transgression of the shoreline. The lowstand erosion surface, which extends from the inner shelf to near the shelfbreak and from the Eel River to Trinidad Head (???80 km), truncates underlying strata on the shelf. Above the surface, inferred transgressive coastal and estuarine sedimentary units separate it from the transgressive surface on the shelf. Early in the transgression, Eel River sediment was likely both transported down the Eel Canyon and dispersed on the slope, allowing transgressive coastal sediment from the smaller Mad River to accumulate in a recognizable deposit on the shelf. The location of coastal Mad River sediment accumulation was controlled by the location of the paleo-Mad River. Throughout the remainder of the transgression, dispersed sediment from the Eel River accumulated an average of 20 m of onlapping shelf deposits. The distribution and thickness of these transgressive marine units was strongly modified by northwest-southeast trending folds. Thick sediment packages accumulated over structural lows in the lowstand surface. The thinnest sediment accumulations (0-10 m) were deposited over structural highs along faults and uplifting anticlines. The Eel margin, an active margin with steep, high sediment-load streams, has developed a thick transgressive systems tract. On this margin sediment accumulates as rapidly as the processes of uplift and downwarp locally create and destroy accommodation space. Sequence stratigraphic models of tectonically active margins should account for variations in accommodation space along margins as well as across them. ?? 2003 Elsevier Science B.V. All rights reserved.

  8. Determination of Proton dose distal fall-off location by detecting right-angled prompt gamma rays

    International Nuclear Information System (INIS)

    Seo, Kyu Seok

    2006-02-01

    The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume while effectively sparing the neighboring healthy tissue and organs. The number of proton therapy facility is very rapidly increasing in the world. And now the 230 MeV cyclotron facility for proton therapy is constructing at National Cancer Center, this facility until 2006. The distal fall-off location of proton beam is simply calculated by analytical method, but this method has many uncertain when anatomical structure is very complicated. It is very important to know the exact position of the proton beam distal fall-off, or beam range, in the patient's body for both the safety of the patient and the effectiveness of the treatment itself. In 2003, Stichelbaut and Jongen reported the possibility of using the right-angled prompt gamma rays, which are emitted at 90 .deg. from the incident proton beam direction, to determine the position of the proton beam distal fall-off. They studied the interactions of the protons and other secondary particles in a water phantom and concluded that there is a correlation between the position of the distal fall-off and the distribution of the right-angled prompt gamma rays. We have recently designed a prompt gamma scanning system to measure the proton range in situ by using Monte Carlo technique employing MCNPX, FLUKA, and Sabrina TM . The prompt gamma scanning system was designed to measure only the right-angled prompt gamma rays passing through a narrow collimation hole in order to correlate the position with the dose distribution. The collimation part of the scanning system, which has been constructed to measure the gamma rays at 70 MeV of proton energy, is made of a set of paraffin, boron carbide, and lead layers to shield the high-energy neutrons and secondary photons. After the different proton energies and SOBP beam widths are irradiated at the water phantom. we detected prompt gamma at 5 cm

  9. Determining Methane Leak Locations and Rates with a Wireless Network Composed of Low-Cost, Printed Sensors

    Science.gov (United States)

    Smith, C. J.; Kim, B.; Zhang, Y.; Ng, T. N.; Beck, V.; Ganguli, A.; Saha, B.; Daniel, G.; Lee, J.; Whiting, G.; Meyyappan, M.; Schwartz, D. E.

    2015-12-01

    We will present our progress on the development of a wireless sensor network that will determine the source and rate of detected methane leaks. The targeted leak detection threshold is 2 g/min with a rate estimation error of 20% and localization error of 1 m within an outdoor area of 100 m2. The network itself is composed of low-cost, high-performance sensor nodes based on printed nanomaterials with expected sensitivity below 1 ppmv methane. High sensitivity to methane is achieved by modifying high surface-area-to-volume-ratio single-walled carbon nanotubes (SWNTs) with materials that adsorb methane molecules. Because the modified SWNTs are not perfectly selective to methane, the sensor nodes contain arrays of variously-modified SWNTs to build diversity of response towards gases with adsorption affinity. Methane selectivity is achieved through advanced pattern-matching algorithms of the array's ensemble response. The system is low power and designed to operate for a year on a single small battery. The SWNT sensing elements consume only microwatts. The largest power consumer is the wireless communication, which provides robust, real-time measurement data. Methane leak localization and rate estimation will be performed by machine-learning algorithms built with the aid of computational fluid dynamics simulations of gas plume formation. This sensor system can be broadly applied at gas wells, distribution systems, refineries, and other downstream facilities. It also can be utilized for industrial and residential safety applications, and adapted to other gases and gas combinations.

  10. Utilizing NASA EOS to Assist in Determining Suitable Planting Locations for Bottomland Hardwood Trees in St. Bernard Parish, Louisiana

    Science.gov (United States)

    Reahard, R. R.; Arguelles, M.; Ewing, M.; Kelly, C.; Strong, E.

    2012-12-01

    St. Bernard Parish, located in southeast Louisiana, is rapidly losing coastal forests and wetlands due to a variety of natural and anthropogenic disturbances (e.g. subsidence, saltwater intrusion, low sedimentation, nutrient deficiency, herbivory, canal dredging, levee construction, spread of invasive species, etc.). After Hurricane Katrina severely impacted the area in 2005, multiple Non-Governmental Organizations (NGOs) have focused not only on rebuilding destroyed dwellings, but on rebuilding the ecosystems that once protected the citizens of St. Bernard Parish. Volunteer groups, NGOs, and government entities often work separately and independently of each other and use different sets of information to choose the best planting sites for restoring coastal forests. Using NASA Earth Observing Systems (EOS), Natural Resource Conservation Service (NRCS) soil surveys, and ancillary road and canal data in conjunction with ground truthing, the team created maps of optimal planting sites for several species of bottomland hardwood trees to aid in unifying these organizations, who share a common goal, under one plan. The methodology for this project created a comprehensive Geographic Information System (GIS) to help identify suitable planting sites in St. Bernard Parish. This included supplementing existing elevation data using Digital Elevation Models derived from LIDAR data, and determining existing land cover in the study area from classified Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) imagery. Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data from a single low-altitude swath was used to assess the health of vegetation over an area near the Mississippi River Gulf Outlet Canal (MRGO) and Bayou La Loutre. Historic extent of coastal forests was also mapped using aerial photos collected between 1952 and 1956. The final products demonstrated yet another application of NASA EOS in the rebuilding and monitoring of coastal ecosystems in

  11. Magnetic Data Interpretation for the Source-Edge Locations in Parts of the Tectonically Active Transition Zone of the Narmada-Son Lineament in Central India

    Science.gov (United States)

    Ghosh, G. K.

    2016-02-01

    The study has been carried out in the transition zone of the Narmada-Son lineament (NSL) which is seismically active with various geological complexities, upwarp movement of the mantle material into the crust through fault, fractures lamination and upwelling. NSL is one of the most prominent lineaments in central India after the Himalaya in the Indian geology. The area of investigation extends from longitude 80.25°E to 81.50°E and latitude 23.50°N to 24.37°N in the central part of the Indian continent. Different types of subsurface geological formations viz. alluvial, Gondwana, Deccan traps, Vindhyan, Mahakoshal, Granite and Gneisses groups exist in this area with varying geological ages. In this study area tectonic movement and crustal variation have been taken place during the past time and which might be reason for the variation of magnetic field. Magnetic anomaly suggests that the area has been highly disturbed which causes the Narmada-Son lineament trending in the ENE-WSW direction. Magnetic anomaly variation has been taken place due to the lithological variations subject to the changes in the geological contacts like thrusts and faults in this area. Shallow and deeper sources have been distinguished using frequency domain analysis by applying different filters. To enhance the magnetic data, various types of derivatives to identify the source-edge locations of the causative source bodies. The present study carried out the interpretation using total horizontal derivative, tilt angle derivative, horizontal tilt angle derivative and Cos (θ) derivative map to get source-edge locations. The results derived from various derivatives of magnetic data have been compared with the basement depth solutions calculated from 3D Euler deconvolution. It is suggested that total horizontal derivative, tilt angle derivative and Cos (θ) derivative are the most useful tools for identifying the multiple source edge locations of the causative bodies in this tectonically active

  12. Gravitational wave sources from Pop III stars are preferentially located within the cores of their host Galaxies

    Science.gov (United States)

    Pacucci, Fabio; Loeb, Abraham; Salvadori, Stefania

    2017-10-01

    The detection of gravitational waves (GWs) generated by merging black holes has recently opened up a new observational window into the Universe. The mass of the black holes in the first and third Laser Interferometer Gravitational Wave Observatory (LIGO) detections (36-29 M⊙ and 32-19 M⊙) suggests low-metallicity stars as their most likely progenitors. Based on high-resolution N-body simulations, coupled with state-of-the-art metal enrichment models, we find that the remnants of Pop III stars are preferentially located within the cores of galaxies. The probability of a GW signal to be generated by Pop III stars reaches ∼90 per cent at ∼0.5 kpc from the galaxy centre, compared to a benchmark value of ∼5 per cent outside the core. The predicted merger rates inside bulges is ∼60 × βIII Gpc-3 yr-1 (βIII is the Pop III binarity fraction). To match the 90 per cent credible range of LIGO merger rates, we obtain: 0.03 proof for the existence of Pop III stars.

  13. Location and wavefield attributes of long-period signals at Villarrica volcano (Chile) determined by array and polarization-moveout analysis

    Science.gov (United States)

    Lehr, Johanna; Thorwart, Martin; Rabbel, Wolfgang

    2016-04-01

    Villarrica Volcano is the most active volcano in Chile whose latest eruption occurred in March 2015. Increasing the knowledge on its processes, structure and behavior is thus crucial to an effective monitoring and hazard assessment. In this context, long-period volcanic signals (LP) are considered to be a key to the understanding of fluid dynamics and volcanic plumbing systems, accessible by seismological observations. However, standard seismological location tools usually fail due to the emergent onset of the signal and its serious distortion caused by attenuation and scattering in a complex geology. Therefore, alternative methods are needed. In March 2012, a dense seismic network was installed at Villarrica for two weeks with 50 stations covering the volcanic edifice including 6 subarrays. About 400 LP events were identified. LP-events recorded on crater stations look similar to typical earthquakes arrivals with distinguishable P- and S-wave onsets indicating a source near the crater. But with increasing source distance waveforms gradually change into typical LP-events. To investigate how to locate these LP-events we tested two approaches at the basis of a show-case event. In a first trial, records of the subarrays were used to determine backazimuths and slowness by beamforming in the time domain. The analysis was performed in a moving window, using semblance to measure the beam quality. The epicenter was derived by intersecting azimuthal rays. It locates ca. 1 km southeast of the summit crater. Slownesses range from 0.5 s/km up to 2.0 s/km. At frequencies above 2 Hz, additional maxima appear in the semblance distribution of near-summit arrays which can be interpreted as side-scattered signals. Since the crossing points of the backazimuth rays showed some scattering we tested polarization analysis (applied to the subset of 3-component stations) as an alternative location method. Although the direct interpretation of the backazimuths was unreliable, we identified

  14. Implications of wall recycling and carbon source locations on core plasma fueling and impurity content in DIII-D

    International Nuclear Information System (INIS)

    Groth, M.; Porter, G.D.; Fenstermacher, M.E.; Lasnier, C.J.; Meyer, W.M.; Rensink, M.E.; Wolf, N.S.; Boedo, J.A.; Moyer, R.A.; Rudakov, D.L.; Brooks, N.H.; Groebner, R.J.; Petrie, T.W.; Owen, L.W.; Wang, G.; Zeng, L.; Watkins, J.G.

    2005-01-01

    Measurement and modeling of the 2-D poloidal D α intensity distribution in DIII-D low and medium density L-mode and ELMy H-mode plasmas indicate that hydrogen neutrals predominantly fuel the core from the divertor X-point region. The 2-D distribution of neutral deuterium and low-charge-state carbon were measured in the divertor and the high-field side midplane scrape-off layer (SOL) using tangentially viewing cameras. The emission in the high-field SOL at the equatorial plane was found to be three to four orders of magnitude lower than at the strike points in the divertor, suggesting a strong divertor particle source. Modeling using the UEDGE/DEGAS codes predicted the poloidal fueling distribution to be dependent on the direction of the ion Bx∇B drift. In plasmas with the Bx∇B drift into the divertor stronger fueling from the inner divertor than from the outer is predicted, due to a lower-temperature and higher-density plasma in the inner leg. UEDGE simulations with carbon produced by both physical and chemical sputtering at the divertor plates and walls only are in agreement with a large set of diagnostic data. The simulations indicate flow reversal in the inner divertor that augments the leakage of carbon ions from the divertor into the core. (author)

  15. Mental Health and Drivers of Need in Emergent and Non-Emergent Emergency Department (ED) Use: Do Living Location and Non-Emergent Care Sources Matter?

    Science.gov (United States)

    McManus, Moira C; Cramer, Robert J; Boshier, Maureen; Akpinar-Elci, Muge; Van Lunen, Bonnie

    2018-01-13

    Emergency department (ED) utilization has increased due to factors such as admissions for mental health conditions, including suicide and self-harm. We investigate direct and moderating influences on non-emergent ED utilization through the Behavioral Model of Health Services Use. Through logistic regression, we examined correlates of ED use via 2014 New York State Department of Health Statewide Planning and Research Cooperative System outpatient data. Consistent with the primary hypothesis, mental health admissions were associated with emergent use across models, with only a slight decrease in effect size in rural living locations. Concerning moderating effects, Spanish/Hispanic origin was associated with increased likelihood for emergent ED use in the rural living location model, and non-emergent ED use for the no non-emergent source model. 'Other' ethnic origin increased the likelihood of emergent ED use for rural living location and no non-emergent source models. The findings reveal 'need', including mental health admissions, as the largest driver for ED use. This may be due to mental healthcare access, or patients with mental health emergencies being transported via first responders to the ED, as in the case of suicide, self-harm, manic episodes or psychotic episodes. Further educating ED staff on this patient population through gatekeeper training may ensure patients receive the best treatment and aid in driving access to mental healthcare delivery changes.

  16. Connecting smoke plumes to sources using Hazard Mapping System (HMS) smoke and fire location data over North America

    Science.gov (United States)

    Brey, Steven J.; Ruminski, Mark; Atwood, Samuel A.; Fischer, Emily V.

    2018-02-01

    Fires represent an air quality challenge because they are large, dynamic and transient sources of particulate matter and ozone precursors. Transported smoke can deteriorate air quality over large regions. Fire severity and frequency are likely to increase in the future, exacerbating an existing problem. Using the National Environmental Satellite, Data, and Information Service (NESDIS) Hazard Mapping System (HMS) smoke data for North America for the period 2007 to 2014, we examine a subset of fires that are confirmed to have produced sufficient smoke to warrant the initiation of a U.S. National Weather Service smoke forecast. We find that gridded HMS-analyzed fires are well correlated (r = 0.84) with emissions from the Global Fire Emissions Inventory Database 4s (GFED4s). We define a new metric, smoke hours, by linking observed smoke plumes to active fires using ensembles of forward trajectories. This work shows that the Southwest, Northwest, and Northwest Territories initiate the most air quality forecasts and produce more smoke than any other North American region by measure of the number of HYSPLIT points analyzed, the duration of those HYSPLIT points, and the total number of smoke hours produced. The average number of days with smoke plumes overhead is largest over the north-central United States. Only Alaska, the Northwest, the Southwest, and Southeast United States regions produce the majority of smoke plumes observed over their own borders. This work moves a new dataset from a daily operational setting to a research context, and it demonstrates how changes to the frequency or intensity of fires in the western United States could impact other regions.

  17. The regulation for delivery of subsidies for measures of promoting power source location for nuclear power generating facilities

    International Nuclear Information System (INIS)

    1984-01-01

    According to the law for the arrangement of surrounding areas of power generating facilities, the regulations concern the allocation of subsidies to promote the most efficient way of siting nuclear power facilities. The contents consist of the following: limits on the subsidies, terms of subsidy allocations, the sum of subsidies for each respective year, applications for subsidies, determination of subsidy allocations, withdrawal of applications, the conditions attached to the allocations, a report on the work proceedings, a report on the results, confirmation on the sum of the subsidies, withdrawal of the decision for subsidies, limitations for disposal of the properties, payment of subsidies, accounting of the subsidy operations, a record of the subsidies, and the chief in the governmental office concerned. (Mori, K.)

  18. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  19. Hydrochemical determination of source water contributions to Lake Lungo and Lake Ripasottile (central Italy

    Directory of Open Access Journals (Sweden)

    Claire Archer

    2016-12-01

    Full Text Available Lake Lungo and Lake Ripasottile are two shallow (4-5 m lakes located in the Rieti Basin, central Italy, that have been described previously as surface outcroppings of the groundwater table. In this work, the two lakes as well as springs and rivers that represent their potential source waters are characterized physio-chemically and isotopically, using a combination of environmental tracers. Temperature and pH were measured and water samples were analyzed for alkalinity, major ion concentration, and stable isotope (δ2H, δ18O, δ13C of dissolved inorganic carbon, and δ34S and δ18O of sulfate composition.  Chemical data were also investigated in terms of local meteorological data (air temperature, precipitation to determine the sensitivity of lake parameters to changes in the surrounding environment. Groundwater represented by samples taken from Santa Susanna Spring was shown to be distinct with SO42- and Mg2+ content of 270 and 29 mg/L, respectively, and heavy sulfate isotopic composition (δ34S=15.2 ‰ and δ18O=10‰. Outflow from the Santa Susanna Spring enters Lake Ripasottile via a canal and both spring and lake water exhibits the same chemical distinctions and comparatively low seasonal variability. Major ion concentrations in Lake Lungo are similar to the Vicenna Riara Spring and are interpreted to represent the groundwater locally recharged within the plain. The δ13CDIC exhibit the same groupings as the other chemical parameters, providing supporting evidence of the source relationships. Lake Lungo exhibited exceptional ranges of δ13CDIC (±5 ‰ and δ2H, δ18O (±5 ‰ and ±7 ‰, respectively, attributed to sensitivity to seasonal changes. The hydrochemistry results, particularly major ion data, highlight how the two lakes, though geographically and morphologically similar, represent distinct hydrochemical facies. These data also show a different response in each lake to temperature and precipitation patterns in the basin that

  20. An application of time-frequency signal analysis technique to estimate the location of an impact source on a plate type structure

    International Nuclear Information System (INIS)

    Park, Jin Ho; Lee, Jeong Han; Choi, Young Chul; Kim, Chan Joong; Seong, Poong Hyun

    2005-01-01

    It has been reviewed whether it would be suitable that the application of the time-frequency signal analysis techniques to estimate the location of the impact source in plate structure. The STFT(Short Time Fourier Transform), WVD(Wigner-Ville distribution) and CWT(Continuous Wavelet Transform) methods are introduced and the advantages and disadvantages of those methods are described by using a simulated signal component. The essential of the above proposed techniques is to separate the traveling waves in both time and frequency domains using the dispersion characteristics of the structural waves. These time-frequency methods are expected to be more useful than the conventional time domain analyses for the impact localization problem on a plate type structure. Also it has been concluded that the smoothed WVD can give more reliable means than the other methodologies for the location estimation in a noisy environment

  1. The regulation for delivery of subsidies for measures of promoting power source location for nuclear power generating facilities

    International Nuclear Information System (INIS)

    1979-01-01

    The regulation is defined under the law for arrangement of surrounding areas of power generating facilities and the law concerning subsidies and others. Limits of the subsidies are stipulated respectively for establishment of a unit and simultaneous construction of more than 2 units of power generating facilities in the area of self-governing bodies concerned. Limits of the subsidies for an arrangement business out of the area of self-governing bodies where the facilities are set up shall be equal to those of the subsidies for such bodies. The Director General of Science and Technology Agency and the Minister of International Trade and Industry may make the amounts otherwise determined the limits of the subsidies, when considered necessary successfully to build the facilities. The term of delivery is from a fiscal year in which a later one of either the day of beginning of the construction concerned or the day of acknowledgment of the arrangement program of the business is included, through a fiscal year when the work finishes. An application for subsidies shall be filed to the head of the authorities concerned with gists of the business according to the forms attached. Receiving the application, the head of the authorities shall examine it and notify to the applicant without delay in writing the decision of delivery and its conditions, when such settlement is made. (Okada, K.)

  2. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  3. A photon spectrometric dose-rate constant determination for the Advantage™ Pd-103 brachytherapy source

    OpenAIRE

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage™ Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and ...

  4. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  5. Alpha spectrometry of thick sources. I. Application to alpha emitters determination

    International Nuclear Information System (INIS)

    Acena, M.L.; Garcia-Torano, E.; Rivero, M.C.

    1977-01-01

    A method for determining alpha emitters by silicon surface barrier detector spectroscopy using thick sources is studied. Two types of spectra have been obtained. They have different shapes of line according to the procedure used for preparing the sources. For both spectra a computing least square programme has been developed. In this way it is possible to calculate line intensities with accuracy better than 20 percent. (author) [es

  6. The determination of a neutron source position in an unknown homogeneous medium: The planar case

    International Nuclear Information System (INIS)

    Dubinski, S.; Talmor, A.; Presler, O.; Tshuva, A.; Yaar, I.; Orion, I.; Alfassi, Z.B.

    2005-01-01

    The possibility of localization of an unknown neutron source in various bulky homogeneous media (box) was studied. For the planar case, two 3 He detectors on the opposite faces of the box were used. A constant polypropylene shield around the box and detectors was used to eliminate the varying contribution from the environment to increase count rates of the detectors and to protect the experimentalist. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron detectors positioned on parallel faces of the box, coplanar with the source. The localization requires measurement of the count rate of both the unknown source and an extra source positioned on one of the faces of the box. The localization is based on the finding that the ratio of the count rates of the two detectors is an exponential function of the distance of the source from one of the detectors

  7. Genetic variation in total number and locations of GnRH neurons identified using in situ hybridization in a wild-source population.

    Science.gov (United States)

    Kaugars, Katherine E; Rivers, Charlotte I; Saha, Margaret S; Heideman, Paul D

    2016-02-01

    The evolution of brain function in the regulation of physiology may depend in part upon the numbers and locations of neurons. Wild populations of rodents contain natural genetic variation in the inhibition of reproduction by winter-like short photoperiod, and it has been hypothesized that this functional variation might be due in part to heritable variation in the numbers or location of gonadotropin releasing hormone (GnRH) neurons. A naturally variable wild-source population of white-footed mice was used to develop lines artificially selected for or against mature gonads in short, winter-like photoperiods. We compared a selection line that is reproductively inhibited in short photoperiod (Responsive) to a line that is weakly inhibited by short photoperiod (Nonresponsive) for differences in counts of neurons identified using in situ hybridization for GnRH mRNA. There was no effect of photoperiod, but there were 60% more GnRH neurons in total in the Nonresponsive selection line than the Responsive selection line. The lines differed specifically in numbers of GnRH neurons in more anterior regions, whereas numbers of GnRH neurons in posterior areas were not statistically different between lines. We compare these results to those of an earlier study that used immunohistochemical labeling for GnRH neurons. The results are consistent with the hypothesis that the selection lines and natural source population contain significant genetic variation in the number and location of GnRH neurons. The variation in GnRH neurons may contribute to functional variation in fertility that occurs in short photoperiods in the laboratory and in the wild source population in winter. © 2015 Wiley Periodicals, Inc.

  8. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    International Nuclear Information System (INIS)

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  9. Semi-empirical Determination of Detection Efficiency for Voluminous Source by Effective Solid Angle Method

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In the field of γ-ray measurements, the determination of full energy (FE) absorption peak efficiency for a voluminous sample is difficult, because the preparation of the certified radiation source with the same chemical composition and geometry for the original voluminous sample is not easy. In order to solve this inconvenience, simulation or semi-empirical methods are preferred in many cases. Effective Solid Angle (ESA) Code which includes semi-empirical approach has been developed by the Applied Nuclear Physics Group in Seoul National University. In this study, we validated ESA code by using Marinelli type voluminous KRISS (Korea Research Institute of Standards and Science) CRM (Certified Reference Materials) sources and IAEA standard γ-ray point sources. And semi-empirically determined efficiency curve for voluminous source by using the ESA code is compared with the experimental value. We calculated the efficiency curve of voluminous source from the measured efficiency of standard point source by using the ESA code. We will carry out the ESA code validation by measurement of various CRM volume sources with detector of different efficiency.

  10. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2010-02-15

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd

  11. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ( PST Λ) was then compared to those determined by TLD ( TLD Λ) and Monte Carlo ( MC Λ) techniques. A likely consensus Λ value was estimated as the arithmetic mean of the average Λ values determined by each of three different techniques. Results: The average PST Λ value for the three Advantage sources was found to be (0.676±0.026) cGyh -1 U -1 . Intersource variation in PST Λ was less than 0.01%. The PST Λ was within 2% of the reported MC Λ values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported TLD Λ. A likely consensus Λ value was estimated to be (0.688±0.026) cGyh -1 U -1 , similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686±0.033) cGyh -1 U -1 , the NASI (Chatsworth, CA) Model MED3633 (0.688±0.033) cGyh -1 U -1 , and the Best Medical (Springfield, VA) Model 2335 (0.685±0.033) cGyh -1 U -1 103 Pd sources. Conclusions: An independent Λ determination has been performed for the Advantage Pd-103 source. The PST Λ obtained in this work provides additional information

  12. Determination of apical constriction and apical foramen using electronic apex locator in vivo: Comparison between vital and nonvital teeth

    Directory of Open Access Journals (Sweden)

    Gaurav Aggarwal

    2018-01-01

    Conclusion: The study supports that EAL measures the location of AC and apical foramen with similar accuracy in vital and nonvital teeth. Furthermore, the distance between the two is reliable when compared with the actual distance observed under stereomicroscope supporting its widespread usage in clinical endodontics.

  13. 40 CFR 761.283 - Determination of the number of samples to collect and sample collection locations.

    Science.gov (United States)

    2010-07-01

    ...) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Sampling To Verify Completion of Self... cleanup verification conducted in accordance with § 761.61(a)(6), follow the procedures in paragraph (b... verification conducted in accordance with § 761.61(a)(6), follow the procedures in this section for locating...

  14. TCSC control structures for line power scheduling and methods to determine their location and tuning to damp system oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Martins, N; Pinto, H J.C.P.; Bianco, A [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil); Macedo, N J.P. [FURNAS, Rio de Janeiro, RJ (Brazil)

    1994-12-31

    This paper describes control structures and computer methods to enhance the practical use of thyristor controlled series compensation (TCSC) in power systems. The location and controller design of the TCS devices, to damp system oscillations, are based on modal analysis and frequency response techniques, respectively. Results are given for a large practical power system. (author) 15 refs., 18 figs., 5 tabs.

  15. Determination of the chemical yield on the Fricke dosimetry for 192Ir sources used in brachytherapy

    International Nuclear Information System (INIS)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de; Rosado, P.H.

    2015-01-01

    With the aim of developing a primary standard for the absorbed dose to water, for the 192 Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe +3 ), using Fricke dosimetry, for the energy of those sources . The G(Fe +3 ) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for 60 Co energy. The G(Fe +3 ) value for the average energy of 192 Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  16. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  17. New method to determine initial surface water displacement at tsunami source

    Science.gov (United States)

    Lavrentyev, Mikhail; Romanenko, Alexey; Tatarintsev, Pavel

    2013-04-01

    Friday, March 11, 2011 at 05:46:23 UTC, Japan was struck by an 8.9-magnitude earthquake near its Northeastern coast. This is one of the largest earthquakes that Japan has ever experienced. Tsunami waves swept away houses and cars and caused massive human losses. To predict tsunami wave parameters better and faster, we propose to improve data inversion scheme and achieve the performance gain of data processing. One of the reasons of inaccurate predictions of tsunami parameters is that very little information is available about the initial disturbance of the sea bed at tsunami source. In this paper, we suggest a new way of improving the quality of tsunami source parameters prediction. Modern computational technologies can accurately calculate tsunami wave propagation over the deep ocean provided that the initial displacement (perturbation of the sea bed at tsunami source) is known [4]. Direct geophysical measurements provide the location of an earthquake hypocenter and its magnitude (the released energy evaluation). Among the methods of determination of initial displacement the following ones should be considered. Calculation through the known fault structure and available seismic information. This method is widely used and provides useful information. However, even if the exact knowledge about rock blocks shifts is given, recalculation in terms of sea bed displacement is needed. This results in a certain number of errors. GPS data analysis. This method was developed after the December 2004 event in the Indian Ocean. A good correlation between dry land based GPS sensors and tsunami wave parameters was observed in the particular case of the West coast of Sumatra, Indonesia. This approach is very unique and can hardly been used in other geo locations. Satellite image analysis. The resolution of modern satellite images has dramatically improved. In the future, correct data of sea surface displacement will probably be available in real time, right after a tsunamigenic

  18. Application of a Dynamic Fuzzy Search Algorithm to Determine Optimal Wind Plant Sizes and Locations in Iowa

    International Nuclear Information System (INIS)

    Milligan, M. R.; Factor, T.

    2001-01-01

    This paper illustrates a method for choosing the optimal mix of wind capacity at several geographically dispersed locations. The method is based on a dynamic fuzzy search algorithm that can be applied to different optimization targets. We illustrate the method using two objective functions for the optimization: maximum economic benefit and maximum reliability. We also illustrate the sensitivity of the fuzzy economic benefit solutions to small perturbations of the capacity selections at each wind site. We find that small changes in site capacity and/or location have small effects on the economic benefit provided by wind power plants. We use electric load and generator data from Iowa, along with high-quality wind-speed data collected by the Iowa Wind Energy Institute

  19. Application of a Dynamic Fuzzy Search Algorithm to Determine Optimal Wind Plant Sizes and Locations in Iowa

    Energy Technology Data Exchange (ETDEWEB)

    Milligan, M. R., National Renewable Energy Laboratory; Factor, T., Iowa Wind Energy Institute

    2001-09-21

    This paper illustrates a method for choosing the optimal mix of wind capacity at several geographically dispersed locations. The method is based on a dynamic fuzzy search algorithm that can be applied to different optimization targets. We illustrate the method using two objective functions for the optimization: maximum economic benefit and maximum reliability. We also illustrate the sensitivity of the fuzzy economic benefit solutions to small perturbations of the capacity selections at each wind site. We find that small changes in site capacity and/or location have small effects on the economic benefit provided by wind power plants. We use electric load and generator data from Iowa, along with high-quality wind-speed data collected by the Iowa Wind Energy Institute.

  20. Experimental/analytical determination of optimal piezoelectric actuator locations on complex structures based on the actuator power factor

    OpenAIRE

    Bhargava, Adesh

    1995-01-01

    The actuator power factor is defined as the ratio of the total dissipative mechanical power of a PZT actuator to the total supplied electrical power to the PZT actuator. If measured experimentally, it can be used to optinlize the actuator location and configuration for complex structures. The concept of actuator power factor is based on the ability of an integrated induced strain actuator such as a PZT actuator to transfer supplied electrical energy into structural mechanical energy. For a gi...

  1. Relationship between the pitch of modulation collimators and the determination accuracy of source positions

    International Nuclear Information System (INIS)

    Fujii, Masami; Nishimura, Jun

    1989-01-01

    The celestial positions of X-ray bursters and gamma-ray burst sources can be accurately determined with rotating modulation collimators which possess wide fields of view and also high angular resolutions. Since the determination accuracy is dependent on the signal to noise ratio of incident photons, the distribution of signal power is analysed and the optimum pitch of the modulation collimator for a burst of a given size is discussed. (author)

  2. Geodynamic models assist in determining the South Loyalty Basin's slab location and its implications for regional topography

    Science.gov (United States)

    Clark, Stuart R.

    2010-05-01

    In the Western Pacific, two competing kinematic reconstructions exist: one with wholly westward subduction of the Pacific plate at what is now the Tonga-Kermadec trench and one combining a degree of eastward subduction under what has been termed the New Caledonia trench. New seismological observations indicate that eastward subduction could explain the existence of a fast anomaly, the hyothesised South Loyalty Basin slab, below the 660km transition zone distinct from the fast anomaly aligned with the Tonga-Kermadec slab. A plate reconstruction dated from the suggested initiation of New Caledonia subduction in the Eocene has been developed. This reconstruction is then used to predict the thermal history of the region and together provide kinematic and thermal boundary conditions for a regional mantle convection model. The model-predicted location of the South Loyalty Basin slab's location will be presented along with the location's dependence on the mantle rheological parameters and the hotspot reference frame. The implications for the topography of the region will also be discussed.

  3. Preliminary PM2.5 and PM10 fractions source apportionment complemented by statistical accuracy determination

    Directory of Open Access Journals (Sweden)

    Samek Lucyna

    2016-03-01

    Full Text Available Samples of PM10 and PM2.5 fractions were collected between the years 2010 and 2013 at the urban area of Krakow, Poland. Numerous types of air pollution sources are present at the site; these include steel and cement industries, traffic, municipal emission sources and biomass burning. Energy dispersive X-ray fluorescence was used to determine the concentrations of the following elements: Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, As and Pb within the collected samples. Defining the elements as indicators, airborne particulate matter (APM source profiles were prepared by applying principal component analysis (PCA, factor analysis (FA and multiple linear regression (MLR. Four different factors identifying possible air pollution sources for both PM10 and PM2.5 fractions were attributed to municipal emissions, biomass burning, steel industry, traffic, cement and metal industry, Zn and Pb industry and secondary aerosols. The uncertainty associated with each loading was determined by a statistical simulation method that took into account the individual elemental concentrations and their corresponding uncertainties. It will be possible to identify two or more sources of air particulate matter pollution for a single factor in case it is extremely difficult to separate the sources.

  4. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  5. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  6. Determination of void fraction from source range monitor and mass flow rate data

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-09-01

    This is a report on the calculation of the TMI-2 primary coolant system local void fraction from source range neutron flux monitor data and from hot leg mass flowrate meter data during the first 100 minutes of the accident. The methods of calculation of void fraction from the two data sources is explained and the results are compared. It is indicated that the void fraction determined using the mass flowrate data contained an error of unknown magnitude due to the assumption of constant homogeneous volumetric flowrate used in the calculation and required further work. Void fraction determined from the source range monitor data is felt to be usable although an uncertainty analysis has not been performed

  7. Open-Source Low-Cost Wireless Potentiometric Instrument for pH Determination Experiments

    Science.gov (United States)

    Jin, Hao; Qin, Yiheng; Pan, Si; Alam, Arif U.; Dong, Shurong; Ghosh, Raja; Deen, M. Jamal

    2018-01-01

    pH determination is an essential experiment in many chemistry laboratories. It requires a potentiometric instrument with extremely low input bias current to accurately measure the voltage between a pH sensing electrode and a reference electrode. In this technology report, we propose an open-source potentiometric instrument for pH determination…

  8. Demographic Information Sources and Utilization as Determinants of Educational Policy Making in South Western Nigeria

    Science.gov (United States)

    Gbadamosi, Belau Olatunde

    2013-01-01

    The paper examines demographic information sources and utilization as determinants of educational policy making in South West Nigeria. Using validated and structured questionnaire, the study population of 398 officers in the ministries of education in the affected states were enumerated. The study establishes population census, vital registration,…

  9. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  10. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples

    2001-12-01

    This annual technical progress report is for part of Task 4 (site evaluation), Task 5 (2D seismic design, acquisition, and processing), and Task 6 (2D seismic reflection, interpretation, and AVO analysis) on DOE contact number DE-AR26-98FT40369. The project had planned one additional deployment to another site other than Savannah River Site (SRS) or DOE Hanford Site. After the SUBCON midyear review in Albuquerque, NM, it was decided that two additional deployments would be performed. The first deployment is to test the feasibility of using non-invasive seismic reflection and AVO analysis as a monitoring tool to assist in determining the effectiveness of Dynamic Underground Stripping (DUS) in removal of DNAPL. The second deployment is to the Department of Defense (DOD) Charleston Naval Weapons Station Solid Waste Management Unit 12 (SWMU-12), Charleston, SC to further test the technique to detect high concentrations of DNAPL. The Charleston Naval Weapons Station SWMU-12 site was selected in consultation with National Energy Technology Laboratory (NETL) and DOD Naval Facilities Engineering Command Southern Division (NAVFAC) personnel. Based upon the review of existing data and due to the shallow target depth, the project team collected three Vertical Seismic Profiles (VSP) and an experimental P-wave seismic reflection line. After preliminary data analysis of the VSP data and the experimental reflection line data, it was decided to proceed with Task 5 and Task 6. Three high resolution P-wave reflection profiles were collected with two objectives; (1) design the reflection survey to image a target depth of 20 feet below land surface to assist in determining the geologic controls on the DNAPL plume geometry, and (2) apply AVO analysis to the seismic data to locate the zone of high concentration of DNAPL. Based upon the results of the data processing and interpretation of the seismic data, the project team was able to map the channel that is controlling the DNAPL plume

  11. Determination of factors through Monte Carlo method for Fricke dosimetry from 192Ir sources for brachytherapy

    International Nuclear Information System (INIS)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo

    2014-01-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of 192 Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  12. Determination of the effective source of particles associated with pellet injection. Application to ITER

    International Nuclear Information System (INIS)

    Nehme, H.

    2009-11-01

    The determination of the effective source of particle associated with the injection of a pellet requires a thorough description of both pellet ablation and deposited material homogenization. The goal of this report is the description of such a study. In the first part, which is devoted to ablation physics, we first analyze the relative importance of the different processes shielding the pellet against the plasma heat flux, then present an attempt for validating the calculation of the over-ablation due to the suprathermal ion tail generated by the discharge heating systems and then estimate the influence of the initial shape of the pellet on the ablation rate. In the second part, which is devoted to the description of the drift of the pellet deposited material down the magnetic field gradient, we present a critical review of the drift models available up to now, then compare the measured characteristics of deposition profiles to our own simulations, showing a good agreement. This was done for data originating from different machines. Then, we describe the several improvements brought to our model and demonstrate - which is new, that there is a correlation between the location of the maximum of matter deposition and that of integer (and/or half-integer) q-surfaces. It must be noted that the underlying process is intrinsic to our modeling and that our calculations reproduce reasonably well the observed correlation for both the LFS (Low Field Side) and HFS (High Field Side) pellet data bases of Tore Supra and DIII-D. The last part reports on the modeling of pellet injection in ITER. First, from the present design of the pellet injection system, we estimate the expected deposition depth of the pellet material (ρ/a ∼ 0.85) and the flux to be injected for pacing the ELMs (Edge Localized Mode) and maintaining the core density (between 150 and 200 Pam 3 s -1 ). Then, we present a parametric study demonstrating that it is not possible to improve significantly the fuelling

  13. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  14. The Use of LiDAR Elevation Data and Satellite Imagery to Locate Critical Source Areas to Diffuse Pollution in Agricultural Watersheds

    Science.gov (United States)

    Drouin, Ariane; Michaud, Aubert; Thériault, Georges; Beaudin, Isabelle; Rodrigue, Jean-François; Denault, Jean-Thomas; Desjardins, Jacques; Côté, Noémi

    2013-04-01

    In Quebec / Canada, water quality improvement in rural areas greatly depends on the reduction of diffuse pollution. Indeed, point source pollution has been reduced significantly in Canada in recent years by creating circumscribed pits for manure and removing animals from stream. Diffuse pollution differs from point source pollution because it is spread over large areas. In agricultural areas, sediment loss by soil and riverbank erosion along with loss of nutrients (phosphorus, nitrogen, etc.) and pesticides from fields represent the main source of non-point source pollution. The factor mainly responsible for diffuse pollution in agricultural areas is surface runoff occurring in poorly drained areas in fields. The presence of these poorly drained areas is also one of the most limiting factors in crop productivity. Thus, a reconciliation of objectives at the farm (financial concern for farmers) and off-farm concerns (environmental concern) is possible. In short, drainage, runoff, erosion, water quality and crop production are all interconnected issues that need to be tackled together. Two complementary data sources are mainly used in the diagnosis of drainage, surface runoff and erosion : elevation data and multispectral satellite images. In this study of two watersheds located in Québec (Canada), LiDAR elevation data and satellite imagery (QuickBird, Spot and Landsat) were acquired. The studied territories have been partitioned in hydrologic response units (HRUs) according to sub-basins, soils, elevation (topographic index) and land use. These HRUs are afterwards used in a P index software (P-Edit) that calculates the quantities of sediments and phosphorus exported from each HRUs. These exports of sediments and phosphorus are validated with hydrometric and water quality data obtain in two sub-basins and are also compared to soil brightness index derived from multispectral images. This index is sensitive to soil moisture and thus highlights areas where the soil is

  15. Determination of the maximum-depth to potential field sources by a maximum structural index method

    Science.gov (United States)

    Fedi, M.; Florio, G.

    2013-01-01

    A simple and fast determination of the limiting depth to the sources may represent a significant help to the data interpretation. To this end we explore the possibility of determining those source parameters shared by all the classes of models fitting the data. One approach is to determine the maximum depth-to-source compatible with the measured data, by using for example the well-known Bott-Smith rules. These rules involve only the knowledge of the field and its horizontal gradient maxima, and are independent from the density contrast. Thanks to the direct relationship between structural index and depth to sources we work out a simple and fast strategy to obtain the maximum depth by using the semi-automated methods, such as Euler deconvolution or depth-from-extreme-points method (DEXP). The proposed method consists in estimating the maximum depth as the one obtained for the highest allowable value of the structural index (Nmax). Nmax may be easily determined, since it depends only on the dimensionality of the problem (2D/3D) and on the nature of the analyzed field (e.g., gravity field or magnetic field). We tested our approach on synthetic models against the results obtained by the classical Bott-Smith formulas and the results are in fact very similar, confirming the validity of this method. However, while Bott-Smith formulas are restricted to the gravity field only, our method is applicable also to the magnetic field and to any derivative of the gravity and magnetic field. Our method yields a useful criterion to assess the source model based on the (∂f/∂x)max/fmax ratio. The usefulness of the method in real cases is demonstrated for a salt wall in the Mississippi basin, where the estimation of the maximum depth agrees with the seismic information.

  16. Determination of seasonal, diurnal, and height resolved average number concentration in a pollution impacted rural continental location

    Science.gov (United States)

    Bullard, Robert L.; Stanier, Charles O.; Ogren, John A.; Sheridan, Patrick J.

    2013-05-01

    The impact of aerosols on Earth's radiation balance and the associated climate forcing effects of aerosols represent significant uncertainties in assessment reports. The main source of ultrafine aerosols in the atmosphere is the nucleation and subsequent growth of gas phase aerosol precursors into liquid or solid phase particles. Long term records of aerosol number, nucleation event frequency, and vertical profiles of number concentration are rare. The data record from multiagency monitoring assets at Bondville, IL can contribute important information on long term and vertically resolved patterns. Although particle number size distribution data are only occasionally available at Bondville, highly time-resolved particle number concentration data have been measured for nearly twenty years by the NOAA ESRL Global Monitoring Division. Furthermore, vertically-resolved aerosol counts and other aerosol physical parameters are available from more than 300 flights of the NOAA Airborne Aerosol Observatory (AAO). These data sources are used to better understand the seasonal, diurnal, and vertical variation and trends in atmospheric aerosols. The highest peaks in condensation nuclei greater than 14 nm occur during the spring months (May, April) with slightly lower peaks during the fall months (September, October). The diurnal pattern of aerosol number has a midday peak and the timing of the peak has seasonal patterns (earlier during warm months and later during colder months). The seasonal and diurnal patterns of high particle number peaks correspond to seasons and times of day associated with low aerosol mass and surface area. Average vertical profiles show a nearly monotonic decrease with altitude in all months, and with peak magnitudes occurring in the spring and fall. Individual flight tracks show evidence of plumes (i.e., enhanced aerosol number is limited to a small altitude range, is not homogeneous horizontally, or both) as well as periods with enhanced particle number

  17. Determining the temperature and density distribution from a Z-pinch radiation source

    International Nuclear Information System (INIS)

    Matuska, W.; Lee, H.

    1997-01-01

    High temperature radiation sources exceeding one hundred eV can be produced via z-pinches using currently available pulsed power. The usual approach to compare the z-pinch simulation and experimental data is to convert the radiation output at the source, whose temperature and density distributions are computed from the 2-D MHD code, into simulated data such as a spectrometer reading. This conversion process involves a radiation transfer calculation through the axially symmetric source, assuming local thermodynamic equilibrium (LTE), and folding the radiation that reaches the detector with the frequency-dependent response function. In this paper the authors propose a different approach by which they can determine the temperature and density distributions of the radiation source directly from the spatially resolved spectral data. This unfolding process is reliable and unambiguous for the ideal case where LTE holds and the source is axially symmetric. In reality, imperfect LTE and axial symmetry will introduce inaccuracies into the unfolded distributions. The authors use a parameter optimization routine to find the temperature and density distributions that best fit the data. They know from their past experience that the radiation source resulting from the implosion of a thin foil does not exhibit good axial symmetry. However, recent experiments carried out at Sandia National Laboratory using multiple wire arrays were very promising to achieve reasonably good symmetry. For these experiments the method will provide a valuable diagnostic tool

  18. Mobile System for the Measurement of Dose Rates with locations determined by means of satellite positioning technology

    International Nuclear Information System (INIS)

    Baeza, A.; Rio, L.M. del; Macias, J.A.; Vasco, J.

    1998-01-01

    Our laboratory has been developing and implementing a Real Time Radiological Warning Network around the Almaraz Nuclear Power Plant since 1990. It consists of six gamma dosimetry stations, two devices for the detection of radio-iodines and alpha, beta, and gamma emissions in air, a monitor for the continuous measurement of gamma radiation in water, and two basic meteorological stations. In this context, we have developed a mobile station endowed with a device for the measurement of dose rates which uses satellite positioning technology (GPS) so that it can be located remotely. The information gathered is sent back to our central laboratory in real/or deferred time through the digital mobile telephone network. A twofold utility is foreseen for this station: (a) action in the case of a radiological alert situation detected by our network, and (b) the performance of radiological-dosimetric studies of distant geographical zones. (Author)

  19. Locating S-wave sources for the SPE-5 explosion using time reversal methods and a close-in, 1000 sensor network

    Science.gov (United States)

    Myers, S. C.; Pitarka, A.; Mellors, R. J.

    2016-12-01

    The Source Physics Experiment (SPE) is producing new data to study the generation of seismic waves from explosive sources. Preliminary results show that far-field S-waves are generated both within the non-elastic volume surrounding explosive sources and by P- to S-wave scattering. The relative contribution of non-elastic phenomenology and elastic-wave scattering to far-field S-waves has been debated for decades, and numerical simulations based on the SPE experiments are addressing this question. The match between observed and simulated data degrades with event-station distance and with increasing time in each seismogram. This suggests that a more accurate model of subsurface elastic properties could result in better agreement between observed and simulated seismograms. A detailed model of subsurface structure has been developed using geologic maps and the extensive database of borehole logs, but uncertainty in structural details remains high. The large N instrument deployment during the SPE-5 experiment offers an opportunity to use time-reversal techniques to back project the wave field into the subsurface to locate significant sources of scattered energy. The large N deployment was nominally 1000, 5 Hz sensors (500 Z and 500 3C geophones) deployed in a roughly rectangular array to the south and east of the SPE-5 shot. Sensor spacing was nominally 50 meters in the interior portion of the array and 100 meters in the outer region, with two dense lines at 25 m spacing. The array covers the major geologic boundary between the Yucca Flat basin and the granitic Climax Stock in which the SPE experiments have been conducted. Improved mapping of subsurface scatterers is expected to result in better agreement between simulated and observed seismograms and aid in our understanding of S-wave generation from explosions. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.

  20. Determination of 3D location and rotation of lumbar vertebrae in CT images by symmetry-based auto-registration

    Science.gov (United States)

    Vrtovec, Tomaž; Likar, Boštjan; Pernuš, Franjo

    2007-03-01

    Quantitative measurement of vertebral rotation is important in surgical planning, analysis of surgical results, and monitoring of the progression of spinal deformities. However, many established and newly developed techniques for measuring axial vertebral rotation do not exploit three-dimensional (3D) information, which may result in virtual axial rotation because of the sagittal and coronal rotation of vertebrae. We propose a novel automatic approach to the measurement of the location and rotation of vertebrae in 3D without prior volume reformation, identification of appropriate cross-sections or aid by statistical models. The vertebra under investigation is encompassed by a mask in the form of an elliptical cylinder in 3D, defined by its center of rotation and the rotation angles. We exploit the natural symmetry of the vertebral body, vertebral column and vertebral canal by dividing the vertebral mask by its mid-axial, mid-sagittal and mid-coronal plane, so that the obtained volume pairs contain symmetrical parts of the observed anatomy. Mirror volume pairs are then simultaneously registered to each other by robust rigid auto-registration, using the weighted sum of absolute differences between the intensities of the corresponding volume pairs as the similarity measure. The method was evaluated on 50 lumbar vertebrae from normal and scoliotic computed tomography (CT) spinal scans, showing relatively large capture ranges and distinctive maxima at the correct locations and rotation angles. The proposed method may aid the measurement of the dimensions of vertebral pedicles, foraminae and canal, and may be a valuable tool for clinical evaluation of the spinal deformities in 3D.

  1. Integrating cut-and-solve and semi-Lagrangean based dual ascent for the single-source capacitated facility location problem

    DEFF Research Database (Denmark)

    Gadegaard, Sune Lauth

    polytope with generalized upper bounds. From our computational study, we show that the semi-Lagrangean relaxation approach has its merits when the instances are tightly constrained with regards to the capacity of the system, but that it is very hard to compete with a standalone implementation of the cut......This paper describes how the cut-and-solve framework and semi-Lagrangean based dual ascent algorithms can be integrated in two natural ways in order to solve the single source capacitated facility location problem. The first uses the cut-and-solve framework both as a heuristic and as an exact...... solver for the semi-Lagrangean subproblems. The other uses a semi-Lagrangean based dual ascent algorithm to solve the sparse problems arising in the cut-and-solve algorithm. Furthermore, we developed a simple way to separate a special type of cutting planes from what we denote the effective capacity...

  2. Simultaneous Determination of Structure and Event Location Using Body and Surface Wave Measurements at a Single Station: Preparation for Mars Data from the InSight Mission

    Science.gov (United States)

    Panning, M. P.; Banerdt, W. B.; Beucler, E.; Blanchette-Guertin, J. F.; Boese, M.; Clinton, J. F.; Drilleau, M.; James, S. R.; Kawamura, T.; Khan, A.; Lognonne, P. H.; Mocquet, A.; van Driel, M.

    2015-12-01

    An important challenge for the upcoming InSight mission to Mars, which will deliver a broadband seismic station to Mars along with other geophysical instruments in 2016, is to accurately determine event locations with the use of a single station. Locations are critical for the primary objective of the mission, determining the internal structure of Mars, as well as a secondary objective of measuring the activity of distribution of seismic events. As part of the mission planning process, a variety of techniques have been explored for location of marsquakes and inversion of structure, and preliminary procedures and software are already under development as part of the InSight Mars Quake and Mars Structure Services. One proposed method, involving the use of recordings of multiple-orbit surface waves, has already been tested with synthetic data and Earth recordings. This method has the strength of not requiring an a priori velocity model of Mars for quake location, but will only be practical for larger events. For smaller events where only first orbit surface waves and body waves are observable, other methods are required. In this study, we implement a transdimensional Bayesian inversion approach to simultaneously invert for basic velocity structure and location parameters (epicentral distance and origin time) using only measurements of body wave arrival times and dispersion of first orbit surface waves. The method is tested with synthetic data with expected Mars noise and Earth data for single events and groups of events and evaluated for errors in both location and structural determination, as well as tradeoffs between resolvable parameters and the effect of 3D crustal variations.

  3. Determination of the smoke-plume heights with scanning lidar using alternative functions for establishing the atmospheric heterogeneity locations

    Science.gov (United States)

    Vladimir A. Kovalev; Alexander Petkov; Cyle Wold; Wei Min Hao

    2010-01-01

    Data-processing techniques for the scanning lidar data are considered that allow determining the upper and lower boundaries of the smoke plume or smoke layering in the vicinity of wildfires. The task is fulfilled by utilizing the Atmospheric Heterogeneity Height Indicator (AHHI). The AHHI is a histogram, which shows a number of heterogeneity events defined by scanning...

  4. On the Determinations of Class-Based Storage Assignments in AS/RS having two I/O Locations

    NARCIS (Netherlands)

    Ashayeri, J.; Heuts, R.M.J.; Beekhof, M.; Wilhelm, M.R.

    2001-01-01

    This paper presents the use and extension of a geometrical-based algorithmic approach for determining the expected S/R machine cycle times, and therefore warehouse throughput, for class-based storage assignment layouts in an AS/RS.The approach was designed for the purpose of solving a practical

  5. A Location Intelligence System for the Assessment of Pluvial Flooding Risk and the Identification of Storm Water Pollutant Sources from Roads in Suburbanised Areas

    Directory of Open Access Journals (Sweden)

    Szymon Szewrański

    2018-06-01

    Full Text Available The interplay of an ever-growing number of inhabitants, sprawl development, soil sealing, changes in urban traffic characteristics, as well as observed climate trends gives rise to more frequent pluvial flooding in cities, a higher run-off of water, and an increasing pollution of surface water. The aim of this research is to develop a location intelligence system for the assessment of pluvial flooding risks and the identification of storm water pollutant sources from roads in newly-developed areas. The system combines geographic information systems and business intelligence software, and it is based on the original Pluvial Flood Risk Assessment tool. The location intelligence system effectively identifies the spatial and temporal distribution of pluvial flood risks, allows to preliminarily evaluate the total run-off from roads, and helps localise potential places for new water management infrastructure. Further improvements concern the modelling of a flow accumulation and drainage system, the application of weather radar precipitation data, and traffic monitoring and modelling.

  6. Determination of the direction to a source of antineutrinos via inverse beta decay in Double Chooz

    Science.gov (United States)

    Nikitenko, Ya.

    2016-11-01

    To determine the direction to a source of neutrinos (and antineutrinos) is an important problem for the physics of supernovae and of the Earth. The direction to a source of antineutrinos can be estimated through the reaction of inverse beta decay. We show that the reactor neutrino experiment Double Chooz has unique capabilities to study antineutrino signal from point-like sources. Contemporary experimental data on antineutrino directionality is given. A rigorous mathematical approach for neutrino direction studies has been developed. Exact expressions for the precision of the simple mean estimator of neutrinos' direction for normal and exponential distributions for a finite sample and for the limiting case of many events have been obtained.

  7. Source and path parameters determination based on data from the digital accelerometer and CALIXTO networks to assess the seismic hazard

    International Nuclear Information System (INIS)

    Radulian, M.; Anghel, M.; Ardeleanu, L.; Bazacliu, O.; Grecu, B.; Popa, M.; Popescu, E.; Rizescu, M.

    2002-01-01

    For any strategy of seismic risk mitigation, it is essential to have a realistic description of the seismic input that means of the source and structure parameters. The present project is focused on the problem of determining accurate source and structure parameters and to analyze the way these parameters influence the seismic hazard distribution. The main objectives of the project are: determination of seismic source parameters, scaling properties, database of recent earthquakes, seismic source effects on the seismic hazard distribution, seismic attenuation, site effects, realistic scenarios for Vrancea earthquakes. To this purpose, we valorize the data provided by the instruments installed recently on the Romanian territory, in the framework of multiple international cooperation programs. Thus, a new digital accelerometer network was installed between 1996 and 1999 in cooperation with the Institute of Geophysics of the University of Karlsruhe (Germany), and an ample tomography experiment deployed for a 6-month time window (May - November 1999).The results obtained up to now refer to the determination of seismic source parameters and scaling. The source parameters are constrained using the spectral ratio technique and the seismic moment tensor inversion. The spectral ratio method is efficient when pairs of co-located earthquakes recorded at common stations are available. In this case the spectral ratio depends essentially on source only, and corrections for path, local response and instrument are not required. Another advantage of the method is the possibility to determine simultaneously source parameters for both selected events of a pair, if the instrument has a broadband frequency response and the signal/noise ratio is sufficiently high in the frequency domain of interest. The spectral ratio method is applied for 37 events, occurred between 1996 and 2000, with magnitudes between 3.0 and 5.3 in the intermediate-depth range. Seismic moment, source dimension and

  8. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  9. Determination of potential sources of PCBs and PBDEs in sediments of the Niagara River

    Energy Technology Data Exchange (ETDEWEB)

    Samara, Fatin [Department of Chemistry, 611 Natural Science Complex, University at Buffalo, State University of New York, Buffalo, NY 14260-3000 (United States); Tsai, Christina W. [Department of Civil, Structural and Environmental Engineering, 233 Jarvis Hall, University at Buffalo, State University of New York, Buffalo, NY 14260-4400 (United States); Aga, Diana S. [Department of Chemistry, 611 Natural Science Complex, University at Buffalo, The State University of New York, Buffalo, NY 14260-3000 (United States)]. E-mail: dianaaga@buffalo.edu

    2006-02-15

    Sediments from Niagara River, an important waterway connecting two of the Great Lakes (Lake Erie to Lake Ontario), were analyzed for 14 congeners of polychlorinated biphenyls (PCBs) and 9 congeners of polybrominated diphenyl ethers (PBDEs) using accelerated solvent extraction and gas chromatography/mass spectrometry. Total concentrations of PCBs ranged from 1.7 to 124.6 ng/g were PCBs 138 and 153 were found in all samples. All sites but one showed PBDE in sediments with total concentrations as high as 148 ng/g, suggesting that PBDE is becoming an important class of POP. A land-use and coverage map was used to trace potential localized sources of PCB and PBDE contamination. Results indicate that the highest levels of PCBs and PBDEs were found in sediments collected from areas closest to the discharge locations of municipal wastewater treatment plants (WWTP) and local industries. This is the first study that suggests the importance of WWTP discharges as a potential source of PBDE contamination in the Great Lakes. - Wastewater treatment plant discharges are a main source of PCBs and PBDEs to Niagara River sediments.

  10. Methods for the determination of lunisolar precession from observations of extragalactic radio sources

    International Nuclear Information System (INIS)

    Elsmore, B.

    1976-01-01

    Although it is not practicable at present to determine the position or motion of the equinox using radio techniques, lunisolar precession may be determined from measurements at two epochs of differences of (i) Right Ascension -RA, and (ii) Declinations - Dec., of extragalactic radio sources. The determinations are largely free from systematic errors, and the magnitudes of random errors, arising principally from tropospheric irregularities, are given for observations with the Cambridge 5-km telescope. Some first epoch measure-ments have been made with this instrument and it is estimated that by carrying out second epoch measurements after an interval of 5 yr, the centennial value of lunisolar precession will be determined with a standard error of +- 0''.25. (author)

  11. Glovebox enclosed dc plasma source for the determination of metals in plutonium

    International Nuclear Information System (INIS)

    Morris, W.F.

    1986-01-01

    The direct current plasma source of a Beckman Spectraspan IIIB emission spectrometer was enclosed in a glovebox at Lawrence Livermore National Laboratory in December 1982. Since that time, the system has been used for the routine determination of alloy and impurity metals in plutonium. This paper presents the systematic steps involved in developing the glovebox and gives information regarding performance of the plasma in the glovebox and the effectiveness of containment of plutonium. 8 refs., 9 figs., 3 tabs

  12. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  13. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Aasa

    2007-11-01

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192 Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192 Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the ±3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192 Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  14. Determining Sources of Fecal Contamination in Two Rivers of Northumberland County, Virginia

    OpenAIRE

    Szeles, Cheryl Lynne

    2003-01-01

    DETERMINING SOURCES OF FECAL CONTAMINATION IN TWO RIVERS OF NORTHUMBERLAND COUNTY, VIRGINIA By Cheryl Lynne Szeles Dr. Charles Hagedorn III, Chairman Crop and Soil Environmental Sciences (ABSTRACT) The goal of monitoring the water quality of shellfish beds is to provide protection against transmission of water-borne infectious diseases. The Coan River and the Little Wicomico River contain shellfish beds that are closed to harvest due to contamination with fecal ...

  15. Instrumental neutron activation determination of gold in mineral raw materials using a californium neutron source

    International Nuclear Information System (INIS)

    Shilo, N.A.; Ippolitov, E.G.; Ivanenko, V.V.; Kustov, B.N.; Zheleznov, V.V.; Aristov, G.N.; Kovalenko, V.V.; Kondrat'ev, N.B.

    1983-01-01

    A facility using a californium neutron source and a method for the neutron activation analysis of gold were developed. The sensitivity of the determination is 0.1 g/t. The causes of random and systematic errors have been studied. It is concluded that in prospection and evaluation of gold ore deposists, the traditional test tube analysis for gold may be replaced with the developed method. (author)

  16. Determination of dosimetric characteristics of OptiSeedTM a plastic brachytherapy 103Pd source

    International Nuclear Information System (INIS)

    Wang Zhonglu; Hertel, Nolan E.

    2005-01-01

    A new 103 Pd plastic brachytherapy source, OptiSeed TM Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water TM . MCNP5 calculations were performed to determine the dose distributions in Virtual Water TM and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water TM phantom was determined to be 0.727±6.9% cGy h -1 U -1 , and the computed value is 0.716±2.1% cGy h -1 U -1 . The Monte-Carlo simulation yielded a dose rate constant of 0.665±2.1% cGy h -1 U -1 in water. The measured dose rate constant in water is 0.675±7.5% cGy h -1 U -1 . It is determined by multiplying the dose rate constant measured in the Virtual Water TM phantom with the ratio of the value calculated in water to that in Virtual Water TM . The average of the measured and calculated dose rate constant is 0.670±5.5% cGy h -1 U -1 . The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water TM phantom. The anisotropy functions in Virtual Water TM phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water TM phantom and water are reported

  17. Dosimetry audit on the accuracy of {sup 192}Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in {sup 192}Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an {sup 192}Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the {+-}3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The {sup 192}Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI.

  18. Determination of optimal geometry for cylindrical sources for gamma radiation measurements; Odredjivanje optimalne geometrije za mjerenje gama zracenja cilindrichnih izvora

    Energy Technology Data Exchange (ETDEWEB)

    Sinjeri, Lj; Kulisic, P [Elektra - Zagreb, Zagreb (Yugoslavia)

    1990-07-01

    Low radioactive sources were used for experimental determination of optimal dimensions for cylindrical source using coaxial Ge(Li) detector. Then, calculational procedure is used to find optimal dimensions of cylindrical source. The results from calculational procedure confirm with experimental results. In such way the verification of calculational procedure is done and it can be used for determination of optimal geometry for low radioactive cylindrical sources. (author)

  19. STATCONT: A statistical continuum level determination method for line-rich sources

    Science.gov (United States)

    Sánchez-Monge, Á.; Schilke, P.; Ginsburg, A.; Cesaroni, R.; Schmiedeke, A.

    2018-01-01

    STATCONT is a python-based tool designed to determine the continuum emission level in spectral data, in particular for sources with a line-rich spectrum. The tool inspects the intensity distribution of a given spectrum and automatically determines the continuum level by using different statistical approaches. The different methods included in STATCONT are tested against synthetic data. We conclude that the sigma-clipping algorithm provides the most accurate continuum level determination, together with information on the uncertainty in its determination. This uncertainty can be used to correct the final continuum emission level, resulting in the here called `corrected sigma-clipping method' or c-SCM. The c-SCM has been tested against more than 750 different synthetic spectra reproducing typical conditions found towards astronomical sources. The continuum level is determined with a discrepancy of less than 1% in 50% of the cases, and less than 5% in 90% of the cases, provided at least 10% of the channels are line free. The main products of STATCONT are the continuum emission level, together with a conservative value of its uncertainty, and datacubes containing only spectral line emission, i.e., continuum-subtracted datacubes. STATCONT also includes the option to estimate the spectral index, when different files covering different frequency ranges are provided.

  20. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array

    Directory of Open Access Journals (Sweden)

    Yankui Zhang

    2018-05-01

    Full Text Available Direct position determination (DPD is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer–Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  1. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array.

    Science.gov (United States)

    Zhang, Yankui; Ba, Bin; Wang, Daming; Geng, Wei; Xu, Haiyun

    2018-05-08

    Direct position determination (DPD) is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer⁻Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  2. Event Coverage Detection and Event Source Determination in Underwater Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Zhangbing Zhou

    2015-12-01

    Full Text Available With the advent of the Internet of Underwater Things, smart things are deployed in the ocean space and establish underwater wireless sensor networks for the monitoring of vast and dynamic underwater environments. When events are found to have possibly occurred, accurate event coverage should be detected, and potential event sources should be determined for the enactment of prompt and proper responses. To address this challenge, a technique that detects event coverage and determines event sources is developed in this article. Specifically, the occurrence of possible events corresponds to a set of neighboring sensor nodes whose sensory data may deviate from a normal sensing range in a collective fashion. An appropriate sensor node is selected as the relay node for gathering and routing sensory data to sink node(s. When sensory data are collected at sink node(s, the event coverage is detected and represented as a weighted graph, where the vertices in this graph correspond to sensor nodes and the weight specified upon the edges reflects the extent of sensory data deviating from a normal sensing range. Event sources are determined, which correspond to the barycenters in this graph. The results of the experiments show that our technique is more energy efficient, especially when the network topology is relatively steady.

  3. Eicosapentaenoic acid and docosahexaenoic acid have distinct membrane locations and lipid interactions as determined by X-ray diffraction.

    Science.gov (United States)

    Sherratt, Samuel C R; Mason, R Preston

    2018-01-31

    Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) differentially influence lipid oxidation, signal transduction, fluidity, and cholesterol domain formation, potentially due in part to distinct membrane interactions. We used small angle X-ray diffraction to evaluate the EPA and DHA effects on membrane structure. Membrane vesicles composed of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) and cholesterol (C) (0.3C:POPC mole ratio) were prepared and treated with vehicle, EPA, or DHA (1:10 mol ratio to POPC). Electron density profiles generated from the diffraction data showed that EPA increased membrane hydrocarbon core electron density over a broad area, up to ± 20 Å from the membrane center, indicating an energetically favorable extended orientation for EPA likely stabilized by van der Waals interactions. By contrast, DHA increased electron density in the phospholipid head group region starting at ± 12 Å from the membrane center, presumably due to DHA-surface interactions, with coincident reduction in electron density in the membrane hydrocarbon core centered ± 7-9 Å from the membrane center. The membrane width (d-space) decreased by 5 Å in the presence of vehicle as the temperature increased from 10 °C to 30 °C due to increased acyl chain trans-gauche isomerizations, which was unaffected by addition of EPA or DHA. The influence of DHA on membrane structure was modulated by temperature changes while the interactions of EPA were unaffected. The contrasting EPA and DHA effects on membrane structure indicate distinct molecular locations and orientations that may contribute to observed differences in biological activity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Characterization and treatment of water used for human consumption from six sources located in the Cameron/Tuba City abandoned uranium mining area.

    Science.gov (United States)

    Orescanin, Visnja; Kollar, Robert; Nad, Karlo; Mikelic, Ivanka Lovrencic; Kollar, Iris

    2011-01-01

    The purpose of this research was the characterization and improvement of the quality of water used for human consumption of unregulated/regulated water sources located in the Cameron/Tuba City abandoned uranium mining area (NE Arizona, western edge of the Navajo Nation). Samples were collected at six water sources which included regulated sources: Wind Mill (Tank 3T-538), Badger Springs and Paddock Well as well as unregulated sources: Willy Spring, Water Wall and Water Hole. Samples taken from Wind Mill, Water Wall and Water Hole were characterized with high turbidity and color as well as high level of manganese, iron and nickel and elevated value of molybdenum. High level of iron was also found in Badger Spring, Willy Spring, and Paddock Well. These three water sources were also characterized with elevated values of fluoride and vanadium. Significant amounts of zinc were found in Water Wall and Water Hole samples. Water Wall sample was also characterized with high level of Cr(VI). Compared to primary or secondary Navajo Nation Environmental Protection Agency (NNEPA) water quality standard the highest enrichment was found for turbidity (50.000 times), color (up to 1.796 times) and manganese (71 times), Cr(VI) (17.5 times), iron (7.4 times) and arsenic (5.2 times). Activities of (226)Ra and (238)U in water samples were still in agreement with the maximum contaminant levels. In order to comply with NNEPA water quality standard water samples were subjected to electrochemical treatment. This method was selected due to its high removal efficiency for heavy metals and uranium, lower settlement time, production of smaller volume of waste mud and higher stability of waste mud compared to physico-chemical treatment. Following the treatment, concentrations of heavy metals and activities of radionuclides in all samples were significantly lower compared to NNEPA or WHO regulated values. The maximum removal efficiencies for color, turbidity, arsenic, manganese, molybdenum and

  5. Using high-resolution in situ radon measurements to determine groundwater discharge at a remote location: Tonle Sap Lake, Cambodia

    International Nuclear Information System (INIS)

    Burnett, W.C.; Chanyotha, S.

    2013-01-01

    Tonle Sap Lake (Cambodia) is the largest freshwater lake in SE Asia, and is reported to have one of the highest freshwater fish productions anywhere. During the dry season (November-April) the lake drains through a tributary to the Mekong River. The flow in the connecting tributary completely reverses during the wet monsoon (May-October), adding huge volumes of water back to the lake, increasing its area about fourfold. We hypothesize that nutrients are at least partially delivered via groundwater discharge, especially during the draining portion of the annual flood cycle. We surveyed over 200 km in the northern section of the lake using a customized system that measures natural 222 Rn (radon), temperature, conductivity, GPS coordinates and water depth while underway. Results showed that there were portions of the lake with significant enrichments in radon, indicating likely groundwater inputs. These same areas were generally characterized by lower electrical conductivities. Samples collected from nearby wells also showed a general inverse relationship between radon and conductivity. Our data suggest that groundwater pathways are important, accounting for roughly 10-20 % of the freshwater flow of the Tonle Sap tributary (connection to the Mekong River), the largest single source of fresh water to the lake. Nutrient inputs from these inputs, because of higher concentrations in groundwater, will be correspondingly higher. (author)

  6. Accumulations and sources of uranium, of its daughters and of metallic trace elements in wetlands located around old uranium mining sites

    International Nuclear Information System (INIS)

    Cuvier, Alicia

    2015-01-01

    Uranium mining and uranium ore processing increase the environmental activity of U and Th decay products and trace elements, in particular in case of releases to the adjacent rivers. Contaminants accumulate then preferentially in sedimentation areas (such as ponds or lakes) or in wetlands (peat lands, marshes or riverbanks) located downstream to the mine. Wetlands - generally located at the head of watershed - are particularly sensitive to environmental changes and anthropogenic pressure. This poses a risk of release of contaminants from these accumulation areas. The objective of the present study is to propose an easily reproducible methodology - in particular for the orphan mining sites - to identify and characterize accumulation areas. This study also aims to improve our understanding of the mechanisms of accumulation and release, in these areas. This study was performed around the former mining site of Bertholene (France). Standing and mobile in situ gamma spectrometry is used to accurately locate the accumulation areas. Soils, sediments, vegetation, water and peat are also sampled upstream and downstream of the mine, in order to (a) characterize the activities and the disequilibria of the U-Th decay chains and the associated trace elements according to the scale of observation, (b) understand the mechanisms of accumulation and release and (c) identify the potential sources using geochemical proxies and isotopic analyses. The results obtained show that radionuclides are mainly accumulated in a flooding area located downstream the mine. Strong U-238 activities (≥ 20000 Bq.kg"-"1) and strong Ra-226/U-238 and Th-230/Ra-226 activity ratios are recorded, involving preferential inputs of U-238 and Th-230 during flooding events. Trace element contamination is low, except for Mn, Ba and S. Such contaminations are potentially explained by the geochemical composition of the uranium ore and by the past and current processes of ore and water mine. Sequential extractions

  7. Earthquake location determination using data from DOMERAPI and BMKG seismic networks: A preliminary result of DOMERAPI project

    Energy Technology Data Exchange (ETDEWEB)

    Ramdhan, Mohamad [Study Program of Earth Science, Institut Teknologi Bandung, Jl. Ganesa 10, Bandung, 40132 (Indonesia); Agency for Meteorology, Climatology and Geophysics of Indonesia (BMKG) Jl. Angkasa 1 No. 2 Kemayoran, Jakarta Pusat, 10720 (Indonesia); Nugraha, Andri Dian; Widiyantoro, Sri [Global Geophysics Research Group, Faculty of Mining and Petroleum Engineering, Institut TeknologiBandung, Jl. Ganesa 10, Bandung, 40132 (Indonesia); Métaxian, Jean-Philippe [Institut de Recherche pour le Développement (IRD) (France); Valencia, Ayunda Aulia, E-mail: mohamad.ramdhan@bmkg.go.id [Study Program of Geophysical Engineering, Institut Teknologi Bandung, Jl. Ganesa 10, Bandung, 40132 (Indonesia)

    2015-04-24

    DOMERAPI project has been conducted to comprehensively study the internal structure of Merapi volcano, especially about deep structural features beneath the volcano. DOMERAPI earthquake monitoring network consists of 46 broad-band seismometers installed around the Merapi volcano. Earthquake hypocenter determination is a very important step for further studies, such as hypocenter relocation and seismic tomographic imaging. Ray paths from earthquake events occurring outside the Merapi region can be utilized to delineate the deep magma structure. Earthquakes occurring outside the DOMERAPI seismic network will produce an azimuthal gap greater than 180{sup 0}. Owing to this situation the stations from BMKG seismic network can be used jointly to minimize the azimuthal gap. We identified earthquake events manually and carefully, and then picked arrival times of P and S waves. The data from the DOMERAPI seismic network were combined with the BMKG data catalogue to determine earthquake events outside the Merapi region. For future work, we will also use the BPPTKG (Center for Research and Development of Geological Disaster Technology) data catalogue in order to study shallow structures beneath the Merapi volcano. The application of all data catalogues will provide good information as input for further advanced studies and volcano hazards mitigation.

  8. A fugacity model for source determination of the Lake Baikal region pollution with polychlorinated Biphenyls

    Energy Technology Data Exchange (ETDEWEB)

    Sofiev, M. [Finnish Meteorological Inst., Helsinki (Finland); Galperin, M.; Maslyaev, A. [Inst. of Program Systems, Pereslavl-Zalesskiy (Russian Federation); McLachlan, M. [Stockholm Univ. (Sweden); Wania, F. [Toronto Univ. (Canada)

    2004-09-15

    PCBs were discovered in the Lake Baikal ecosystem by Malakhov et al. and Bobovnikova et al. A follow up to the initial study showed no decrease over 1981-1989 4, in contrast to what has been observed in other water bodies in the industrialised world. Further studies also showed the contamination in pinnipeds to be among the highest measured anywhere. Above studies and other data suggested a presence of a strong local PCB source (or several ones), which has had a widespread adverse effect for the whole region. To locate the source, Mamontov et al. collected samples from 34 sites over the region, the analysis of which showed a gradient of a factor of 1000, with the lowest concentrations at the north-east of Lake Baikal and the highest concentrations close to the city of Usolye Sibirskoye, a centre of the chemical industry in the Angara River valley. A continuous decrease in the soil contamination was observed along the path from Usolye Sibirskoye up the Angara River valley to Lake Baikal and from there north-eastward along the lake. These results indicate that there was (and perhaps still is) a major source of PCBs in the Usolye area, from where the PCBs are dispersed over the region. However, various obstacles prevent direct observations of potential sources. Therefore, a mathematical modelling approach was adopted in a currently ongoing INTAS project aiming to shed some more light on this problem. The model principles, setup and the results of the first experiments are presented in the current paper.

  9. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGETM Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Dini, Sharifeh A.; Awan, Shahid B.; Dou, Kai; Koona, Rafiq A.

    2006-01-01

    ADVANTAGE TM Pd-103 brachytherapy source has been recently introduced by IsoAid TM for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water TM using LiF TLD chips and the theoretical calculations were performed in Solid Water TM and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h -1 U -1 in liquid water and 0.67 cGy h -1 U -1 in Solid Water TM medium. The measured dose rate constant in Solid Water TM was found to be 0.68±8% cGy h -1 U -1 , which is in a good agreement (within ±5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE TM Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L eff equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model

  10. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGE{sup TM} Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Meigooni, Ali S. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)]. E-mail: alimeig@uky.edu; Dini, Sharifeh A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Awan, Shahid B. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Dou, Kai [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Koona, Rafiq A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)

    2006-08-15

    ADVANTAGE{sup TM} Pd-103 brachytherapy source has been recently introduced by IsoAid{sup TM} for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water{sup TM} using LiF TLD chips and the theoretical calculations were performed in Solid Water{sup TM} and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h{sup -1} U{sup -1} in liquid water and 0.67 cGy h{sup -1} U{sup -1} in Solid Water{sup TM} medium. The measured dose rate constant in Solid Water{sup TM} was found to be 0.68{+-}8% cGy h{sup -1} U{sup -1}, which is in a good agreement (within {+-}5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE{sup TM} Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L {sub eff} equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model.

  11. Cellular Phone Towers, Cell tower locations as derived from various sources including the Department of Licenses and Inspections and the Department of Planning and Zoning., Published in 2010, 1:2400 (1in=200ft) scale, Howard County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2010. Cell tower locations as derived from various sources including the Department of Licenses and Inspections and the...

  12. NEAR REAL-TIME DETERMINATION OF EARTHQUAKE SOURCE PARAMETERS FOR TSUNAMI EARLY WARNING FROM GEODETIC OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    S. Manneela

    2016-06-01

    Full Text Available Exemplifying the tsunami source immediately after an earthquake is the most critical component of tsunami early warning, as not every earthquake generates a tsunami. After a major under sea earthquake, it is very important to determine whether or not it has actually triggered the deadly wave. The near real-time observations from near field networks such as strong motion and Global Positioning System (GPS allows rapid determination of fault geometry. Here we present a complete processing chain of Indian Tsunami Early Warning System (ITEWS, starting from acquisition of geodetic raw data, processing, inversion and simulating the situation as it would be at warning center during any major earthquake. We determine the earthquake moment magnitude and generate the centroid moment tensor solution using a novel approach which are the key elements for tsunami early warning. Though the well established seismic monitoring network, numerical modeling and dissemination system are currently capable to provide tsunami warnings to most of the countries in and around the Indian Ocean, the study highlights the critical role of geodetic observations in determination of tsunami source for high-quality forecasting.

  13. Location for new research facility determined X-ray laser XFEL to be realized in the federal states of Hamburg and Schleswig-Holstein starting in 2006

    CERN Multimedia

    2003-01-01

    "...The site for the XFEL has now been determined by the research center DESY (Deutsches Elektronen-Synchrotron); it was announced today at a press conference in Hamburg. The 3.3-kilometer-long facility is to be located in the federal states of Hamburg and Schleswig-Holstein. It will begin on the DESY site in Hamburg-Bahrenfeld and run in a north-western direction to the town of Schenefeld (district of Pinneberg), which borders on Hamburg" (1 page).

  14. Determination and evaluation of effective criteria to location selection the optimal for establishing fluting paper mills from agricultural residues of Mazandaran province

    Directory of Open Access Journals (Sweden)

    Abdollah barimani

    2013-11-01

    Full Text Available Location selection for factory competitiveness in the market place plays an important role and should be chosen so that will leads achievement of the strategic advantages compared with other competitors. The objective of this study was determination of the effective criteria for decision making to select the most suitable location for establishing a fluting paper mills from agricultural residues. For this purpose, effective criteria were divided into five major groups: Material and Product, Facilities and limitations of regional (infrastructure, Technical and Human, Economical, Rules & Regulations as well as 33 sub-criteria, after preliminary investigation, preparatory observation, and an interview with some of the paper producers and relevant experts. A hierarchy was designed based on five major groups of criteria and then the priority rates of obtained criteria and sub-criteria were determined by Analytical Hierarchy Process (AHP after compiling expert's opinions via questionnaire. Results have shown that among 33 determined effective criteria in location selection of fluting paper mills from agricultural residues , the sub-criteria of Supply residual amount, Ensure the supply of residual, Cost purchasing of raw material, Cost of transporting raw material have the highest priorities, respectively

  15. Hydrogen isotopic spectral determination in inert gases with the use of light source with contracted discharge

    International Nuclear Information System (INIS)

    Nemets, V.M.; Solov'ev, A.A.

    1981-01-01

    Isotopic-spectral technique for hydrogen determination in helium, neon and argon is developed. It employs a contracted high-frequency discharge as a light source to decrease the distorting effect. of a dummy signal and the ''memory'' effect of the discharge tube. The discharge is realized in a quartz tube approximately 7 mm dia. and gas pressure in it approximately 6x10 4 Pa. The analysis technique comprises sampling of gas, dosed introduction of deuterium into the sample, selection of a mixture portion into the discharge tube, spectroscopic determination of hydrogen isotope ratio and calculation of the sought for hydrogen concentration. The lower boundary of the determined concentrations of hydrogen constitutes 7x10 - 5 , 2x10 - 4 and 4x10 - 4 volumetric per cent in helium, neon, and argon, respectively

  16. Reliability of trans-abdominal ultrasonography in determining exact location of placenta in patients of placenta previa major

    International Nuclear Information System (INIS)

    Zafar, M.; Hayat, N; Gul, U.

    2017-01-01

    Objective: To determine the reliability of trans-abdominal ultrasonographical localization of placenta in cases of placenta previa major, by taking peroperative finding as gold standard. Study Design: Validation study. Place and Duration of Study: Maternity ward, Obstetrics and Gynecology department, Military Hospital Rawalpindi from 2007 to 2008. Patients and Methods: A total of 100 patients fulfilling the inclusion and exclusion criteria were recruited for the study. These patients were admitted to the maternity ward, where trans-abdominal ultrasound was performed, site of the placenta and its relation to the internal os was documented. These patients under went elective cesarean section, during which the site and relation of the placenta to the internal os was confirmed. Results: The mean age of patients was 34.23 +- 6.76 years. Transabdominal ultrasound had a sensitivity of 93.4 percent in localizing major placenta previa while the specificity was 83 percent. Positive predictive value was 94.7 percent, negative predictive value was 80 percent and accuracy 91 percent. Conclusion: Trans-abdominal ultrasound was found highly effective in diagnosing and localizing placenta previa. (author)

  17. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  18. Determination of the growth of nematophagous fungi on diverse carbon sources

    Directory of Open Access Journals (Sweden)

    Martha Orozco

    2015-11-01

    Full Text Available Organic amendments have been widely used to stimulate the populations of predatory nematophagous fungi (PNF in soil; however, the use of organic amendments has produced inconsistent results in the control of parasitic nematodes. The inconsistencies have been partially attributed to the chemical composition of the organic amendments, specifically to carbon and nitrogen contents. Therefore, to know the carbon preferences of these fungi could be helpful to promote the predatory phase of the PNF in soil. The aim of this study was to determine the growth of native PNF strains from Costa Rica in diverse carbon sources. The PNF Arthrobotrys oligospora and Candelabrella musiformis were grown in artificial culture media containing the following carbon sources: cellulose, chitin, pectin, starch, and skim milk. The growth rate developed by the PNF in each one of the culture media was determined and compared. The growth rates developed by both fungal species followed the next order: cellulos e>chitin>pectin>starch>skim milk. Significant differences in the growth rates developed by the fungal strains were detected only in culture medium containing cellulose, in comparison with culture media containing other carbon sources. In culture medium containing cellulose both A. oligospora and C. musiformis grew faster with respect to the other culture media, but A. oligospora strains grew faster in comparison with C. musiformis strains. Both fungal species developed the lowest growth rates in culture media containing starch and skim milk.

  19. Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

    Directory of Open Access Journals (Sweden)

    Mahdi Jahangir Blourchian

    2015-12-01

    Full Text Available Background: In Neonatal intensive care units (NICU different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the intensity of the sounds generated by the internal and external sources in the NICU and neonatal ward was measured using a sound level meter device. The sound produced by each of the sources was individually calculated. Data were analyzed performing descriptive and analytical statistics, using SPSS version 19. Results: The mean noise levels in six rooms and a hallway during morning, afternoon and night shifts with the electromechanical devices turned on were 61.67±4.5, 61.32±4.32 and 60.71±4.56 dB, respectively. Moreover, with the devices tuned off the mean noise levels during morning, afternoon and evening shifts were 64.97±2.6, 60.6±1.29 and 57.91±4.73 dB, respectively. The differences between the mean noise levels in the neonatal wards (standard noise level=45 dB during each shift with the electromechanical devices turned on and off were statistically significant (P=0.002 and P

  20. Determinants of epidemiologic transition in rural Africa: the role of socioeconomic status and drinking water source.

    Science.gov (United States)

    Engelaer, Frouke M; Koopman, Jacob J E; van Bodegom, David; Eriksson, Ulrika K; Westendorp, Rudi G J

    2014-06-01

    Many African countries experience a protracted epidemiologic transition, different from the classical transition in western societies. The factors driving this protracted transition are largely unknown. In northeast Ghana, we studied an ongoing epidemiologic transition and investigated the effects of socioeconomic status and drinking water source on the transition. During a 9-year period, we followed a cohort of almost 30 000 individuals and collected information on mortality and fertility rates. In addition, using the standards set out by the WHO, we obtained the causes of death by verbal autopsy. Individuals were stratified according to their socioeconomic status and the households' use of an improved or unimproved drinking water source. Mortality rates decreased by -5.0% annually (pwater source. Factors other than socioeconomic status and drinking water source are responsible for the observed declines in mortality and fertility observed during the protracted epidemiologic transition. Identifying the specific determinants of the ongoing transition is of importance, as they could be targeted in order to further improve public health in rural African countries. © The Author 2014. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Tritium-labelled steroids, their preparation and application for the determination and location of steroid tissular hormone receptors

    International Nuclear Information System (INIS)

    Jouquey, Alain; Raynaud, J.P.

    1977-01-01

    A product is prepared by the action of tritiated methanol on 11β-hydroxy-estra-4,9-dien-3,17-dione, the action of an aromatisation agent on the (11β)-11-methoxy- 3 H 3 -estra-4,9-dien-3,17-dione formed and the action of an ethynylation agent on the resulting (11β)-3-hydroxy-11-methoxy- 3 H 3 -estra-1,3,5(10)-trien-17-one giving (11β, 17α)-11-methoxy- 3 H 3 -19-norpregna-1,3,5(10)-trien-20-yne-3,17 diol, the free hydroxyl function or functions of this product may be etherified or esterified as the case may be. The tritiated methanol acts in the presence of perchloric acid. The aromatisation agent is palladium hydroxide and the operation is carried out in methanol. The ethynylation agent is acetylene and the reaction takes place in the presence of sodium t-amylate in toluene. This product allows the study and determination of the estrogen specific receptor present in the tissue cells of target organs for the action of estrogens: uterus, vagina, hypophysis, hypothalamus and tumours, of the breast and prostate for example, in both animals and man. Not being fixed by the plasma proteins binding such hormones as testosterone and estradiol in women the product is an ideal indicator of the tissular estrogen receptor with which it forms a complex of strong affinity and great stability, especially since it interacts with the tissular receptors of no other steroid hormone groups (glucocorticoids, androgen or progestogen mineralocorticosteroids) [fr

  2. Strength Restoration of Cracked Sandstone and Coal under a Uniaxial Compression Test and Correlated Damage Source Location Based on Acoustic Emissions

    Science.gov (United States)

    Feng, Xiaowei; Zhang, Nong; Zheng, Xigui; Pan, Dongjiang

    2015-01-01

    Underground rock masses have shown a general trend of natural balance over billions of years of ground movement. Nonetheless, man-made underground constructions disturb this balance and cause rock stability failure. Fractured rock masses are frequently encountered in underground constructions, and this study aims to restore the strength of rock masses that have experienced considerable fracturing under uniaxial compression. Coal and sandstone from a deep-buried coal mine were chosen as experimental subjects; they were crushed by uniaxial compression and then carefully restored by a chemical adhesive called MEYCO 364 with an innovative self-made device. Finally, the restored specimens were crushed once again by uniaxial compression. Axial stress, axial strain, circumferential strain, and volumetric strain data for the entire process were fully captured and are discussed here. An acoustic emission (AE) testing system was adopted to cooperate with the uniaxial compression system to provide better definitions for crack closure thresholds, crack initiation thresholds, crack damage thresholds, and three-dimensional damage source locations in intact and restored specimens. Several remarkable findings were obtained. The restoration effects of coal are considerably better than those of sandstone because the strength recovery coefficient of the former is 1.20, whereas that of the latter is 0.33, which indicates that MEYCO 364 is particularly valid for fractured rocks whose initial intact peak stress is less than that of MEYCO 364. Secondary cracked traces of restored sandstone almost follow the cracked traces of the initial intact sandstone, and the final failure is mainly caused by decoupling between the adhesive and the rock mass. However, cracked traces of restored coal only partially follow the traces of intact coal, with the final failure of the restored coal being caused by both bonding interface decoupling and self-breakage in coal. Three-dimensional damage source

  3. Strength Restoration of Cracked Sandstone and Coal under a Uniaxial Compression Test and Correlated Damage Source Location Based on Acoustic Emissions.

    Directory of Open Access Journals (Sweden)

    Xiaowei Feng

    Full Text Available Underground rock masses have shown a general trend of natural balance over billions of years of ground movement. Nonetheless, man-made underground constructions disturb this balance and cause rock stability failure. Fractured rock masses are frequently encountered in underground constructions, and this study aims to restore the strength of rock masses that have experienced considerable fracturing under uniaxial compression. Coal and sandstone from a deep-buried coal mine were chosen as experimental subjects; they were crushed by uniaxial compression and then carefully restored by a chemical adhesive called MEYCO 364 with an innovative self-made device. Finally, the restored specimens were crushed once again by uniaxial compression. Axial stress, axial strain, circumferential strain, and volumetric strain data for the entire process were fully captured and are discussed here. An acoustic emission (AE testing system was adopted to cooperate with the uniaxial compression system to provide better definitions for crack closure thresholds, crack initiation thresholds, crack damage thresholds, and three-dimensional damage source locations in intact and restored specimens. Several remarkable findings were obtained. The restoration effects of coal are considerably better than those of sandstone because the strength recovery coefficient of the former is 1.20, whereas that of the latter is 0.33, which indicates that MEYCO 364 is particularly valid for fractured rocks whose initial intact peak stress is less than that of MEYCO 364. Secondary cracked traces of restored sandstone almost follow the cracked traces of the initial intact sandstone, and the final failure is mainly caused by decoupling between the adhesive and the rock mass. However, cracked traces of restored coal only partially follow the traces of intact coal, with the final failure of the restored coal being caused by both bonding interface decoupling and self-breakage in coal. Three

  4. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  5. Determination of delayed neutrons source in the frequency domain based on in-pile oscillation measurements

    International Nuclear Information System (INIS)

    Yedvab, Y.; Reiss, I.; Bettan, M.; Harari, R.; Grober, A.; Ettedgui, H.; Caspi, E. N.

    2006-01-01

    A method for determining delayed neutrons source in the frequency domain based on measuring power oscillations in a non-critical reactor is presented. This method is unique in the sense that the delayed neutrons source is derived from the dynamic behavior of the reactor, which serves as the measurement system. An algorithm for analyzing power oscillation measurements was formulated, which avoids the need for a multi-parameter non-linear fit process used by other methods. Using this algorithm results of two sets of measurements performed in IRR-I and IRR-II (Israeli Research Reactors I and II) are presented. The agreement between measured values from both reactors and calculated values based on Keepin (and JENDL-3.3) group parameters is very good. (authors)

  6. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources

    International Nuclear Information System (INIS)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila

    2014-01-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose

  7. An attempt to determine positions of aerosol source by the PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Tokai, Y.; Ishii, K.

    1999-01-01

    Aerosols were continuously collected for 2 or 3 hours during the periods of 4-27 August 1997 and of 23 March-2 April 1998 at a suburb of Sendai City (east 10 km from Sendai), and meteorological data such as wind directions, wind velocities, etc were measured at the same time. The collected aerosol samples were analyzed by the particle-induced X-ray emission (PIXE) method. Fourteen elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Hg and Pb) were contained in these samples. The elemental concentrations increased in the daytime and decreased at night. It coincided with the time variation of people movement. The concentrations of Mn, Fe, Zn and Pb elements depended strongly on the direction of wind and their distributions for wind directions reflected to the position of aerosol sources. This result suggests that the position of aerosol source can be determined by measuring aerosols and wind directions at the many positions. (author)

  8. Locative media

    CERN Document Server

    Wilken, Rowan

    2014-01-01

    Not only is locative media one of the fastest growing areas in digital technology, but questions of location and location-awareness are increasingly central to our contemporary engagements with online and mobile media, and indeed media and culture generally. This volume is a comprehensive account of the various location-based technologies, services, applications, and cultures, as media, with an aim to identify, inventory, explore, and critique their cultural, economic, political, social, and policy dimensions internationally. In particular, the collection is organized around the perception that the growth of locative media gives rise to a number of crucial questions concerning the areas of culture, economy, and policy.

  9. Experimental determination of the neutron source for the Argonauta reactor subcritical assembly

    Energy Technology Data Exchange (ETDEWEB)

    Renke, Carlos A.C.; Furieri, Rosanne C.A.A.; Pereira, Joao C.S.; Voi, Dante L.; Barbosa, Andre L.N., E-mail: renke@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The utilization of a subcritical assembly for the determination of nuclear parameters in a multiplier medium requires a well defined neutron source to carry out the experiments necessary for the acquisition of the desired data. The Argonauta research reactor installed at the Instituto de Engenharia Nuclear has a subcritical assembly, under development, to be coupled at the upper part of the reactor core that will provide the needed neutrons emerging from its internal thermal column made of graphite. In order to perform neutronic calculations to compare with the experimental results, it is necessary a precise knowledge of the emergent neutron flux that will be used as neutron source in the subcritical assembly. In this work, we present the thermal neutron flux profile determined experimentally via the technique of neutron activation analysis, using dysprosium wires uniformly distributed at the top of the internal thermal neutron column of the Argonauta reactor and later submitted to a detection system using Geiger-Mueller detector. These experimental data were then compared with those obtained through neutronic calculation using HAMMER and CITATION codes in order to validate this calculation system and to define a correct neutron source distribution to be used in the subcritical assembly. This procedure avoids a coupled neutronic calculation of the subcritical assembly and the reactor core. It has also been determined the dimension of the graphite pedestal to be used in the bottom of the subcritical assembly tank in order to smooth the emergent neutron flux at the reactor top. Finally, it is estimated the thermal neutron flux inside the assembly tank when filled with water. (author)

  10. Set of programs for determining exposure and dose rates from selected sources of gamma radiation

    International Nuclear Information System (INIS)

    Hep, J.; Kralovcova, E.; Smutny, V.; Valenta, V.

    1982-01-01

    The programs are described for the determination of exposure and dose rate of gamma radiation from point, surface, linear and volume sources with and without shielding. The computation is conducted using the classical method taking into consideration the buildup factor. For the computation of the buildup factor in heterogeneous shielding the Broder and Kitazuma formulas are used. Kitazuma's alpha coefficients were calculated recurrently using a new semi-empirical method. Taylor's approximation was used for the calculation of the buildup factor in a single layer

  11. Determination of radium isotopes by BaSO4 coprecipitation for the preparation of alpha-spectrometric sources

    International Nuclear Information System (INIS)

    Lozano, J.C.; Fernandez, F.; Gomez, J.M.G.

    1997-01-01

    A coprecipitation procedure for the preparation of α-spectrometric sources for radium, using BaSO 4 as carrier, has been applied to the determination of alpha radium isotopes in water samples. The use of 133 Ba as a suitable tracer for radium determination and possible losses of radon isotopes from the sources are studied and discussed. (author)

  12. DETERMINANTS OF THE ACCURACY OF NURSING DIAGNOSES : INFLUENCE OF READY KNOWLEDGE, KNOWLEDGE SOURCES, DISPOSITION TOWARD CRITICAL THINKING, AND REASONING SKILLS

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; Van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  13. Determinants of the accuracy of nursing diagnoses : influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  14. Simultaneous Determination of Source Wavelet and Velocity Profile Using Impulsive Point-Source Reflections from a Layered Fluid

    National Research Council Canada - National Science Library

    Bube, K; Lailly, P; Sacks, P; Santosa, F; Symes, W. W

    1987-01-01

    .... We show that a quasi-impulsive, isotropic point source may be recovered simultaneously with the velocity profile from reflection data over a layered fluid, in linear (perturbation) approximation...

  15. Tracers application method for the quantitative determination of the source of oxygenic inclusions in steel

    International Nuclear Information System (INIS)

    Rewienska-Kosciukowa, B.; Dalecki, W.; Michalik, J.S.

    1976-01-01

    The sense and the possibility of radioactive and nonradioactive isotopic tracers application in investigations of the origin of oxygenic nonmetalic inclusions is presented. The discussed methods touch the investigations such as the origin of egzogenic inclusions which passed from external sources (fireproof lining, slag) to the steel or as the endogenic ones formed during the process of steel deoxidisation. The question of the tracers choice for refractory material and the further investigations concerned the determination of the origin of nonmetallic inclusions are discussed. The question of so called isotopic replacement tracers for the main steel deoxidizing agents is considered. The criterion of determination of oxygenic inclusions formed during the process of steel deoxidization is also discussed. Several results of laboratory and industrial investigations and also the examples of application of the discussed methods in the industrial scale are presented. (author)

  16. Choice of excitation source for determination of rare earth elements with radioisotope excited X ray fluorescence

    International Nuclear Information System (INIS)

    Zhang Quanshi; Chang Yongfu

    2000-01-01

    The comparisons of two radioisotope source ( 241 Am and 238 Pu) which are the most available in the radioisotope excited X Ray Fluorescence (XRF) analysis technique and two characteristic X ray series (KX and LX) analyzed for the determination of the rare-earth (RE) elements were investigated in detail. According to the principle of emission and detection of X ray , the relative excitation efficiencies were calculated by the some fundamental physical parameters including the photoelectric mass attenuation coefficient, the fluorescent yield, the absorption jump factor, the emission probability of the detected fluorescent line with reference to other liens of the same series etc., The advantages and disadvantages of the two conditions are discussed. These results may determine the optimal excitation and detection conditions for different rare-earth elements. The experimental results with nine rare-earth elements (Ce, Nd, Sm, Tb, Tm, Ho, Er, Yb and Lu) are in agreement with the results of theoretical calculations

  17. Determination, Source Identification and GIS Mapping for Nitrate Concentration in Groundwater from Bara Aquifer

    Energy Technology Data Exchange (ETDEWEB)

    Elami, G. M.; Sam, A. K.; Yagob, T. I.; Siddeeg, S. E.M.B.; Hatim, E.; Hajo, I. [Sudan Atomic Energy Commission, Sudan, Khartoum (Sudan)

    2013-07-15

    This study was carried out to determine the level of nitrate concentration in well water from Bara aquifer in north Kordofan state (west central sudan). The analysis was conducted for 69 wells from different villages within the Bara basin. Spectophotometric analysis was used to determine nitrate, nitrite and ammonia. Results revealed that nitrate concentration range was from 9.68 to 891 mg L in the sampled well with 81% exceeding the maximum permissible limits set for drinking water by WHO and SSMO. Animal waste and organic soil nitrogen were found to be the source of nitrate in these wells as indicated by {sup 15}N. The majority of wells with high nitrate are in the north and the north east part of the study area are shown by the GIS predictive map. (author)

  18. Determination of sources and analysis of micro-pollutants in drinking water

    International Nuclear Information System (INIS)

    Md Pauzi Abdullah; Soh Shiau Chian

    2005-01-01

    The objectives of the study are to develop and validate selected analytical methods for the analysis of micro organics and metals in water; to identify, monitor and assess the levels of micro organics and metals in drinking water supplies; to evaluate the relevancy of the guidelines set in the National Standard of Drinking Water Quality 2001; and to identify the sources of pollution and to carryout risk assessment of exposure to drinking water. The presentation discussed the progress of the work include determination of VOCs (Volatile organic compounds) in drinking water using SPME (Solid phase micro-extraction) extraction techniques, analysis of heavy metals in drinking water, determination of Cr(VI) with ICPES (Inductively coupled plasma emission spectrometry) and the presence of halogenated volatile organic compounds (HVOCs), which is heavily used by agricultural sector, in trace concentrations in waters

  19. Location, location, location: Extracting location value from house prices

    OpenAIRE

    Kolbe, Jens; Schulz, Rainer; Wersing, Martin; Werwatz, Axel

    2012-01-01

    The price for a single-family house depends both on the characteristics of the building and on its location. We propose a novel semiparametric method to extract location values from house prices. After splitting house prices into building and land components, location values are estimated with adaptive weight smoothing. The adaptive estimator requires neither strong smoothness assumptions nor local symmetry. We apply the method to house transactions from Berlin, Germany. The estimated surface...

  20. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  1. Determinants of Internet use as a preferred source of information on personal health.

    Science.gov (United States)

    Lemire, Marc; Paré, Guy; Sicotte, Claude; Harvey, Charmian

    2008-11-01

    To understand the personal, social and cultural factors likely to explain recourse to the Internet as a preferred source of personal health information. A cross-sectional survey was conducted among a population of 2923 Internet users visiting a firmly established website that offers information on personal health. Multiple regression analysis was performed to identify the determinants of site use. The analysis template comprised four classes of determinants likely to explain Internet use: beliefs, intentions, user satisfaction and socio-demographic characteristics. Seven-point Likert scales were used. An analysis of the psychometric qualities of the variables provided compelling evidence of the construct's validity and reliability. A confirmatory factor analysis confirmed the correspondence with the factors predicted by the theoretical model. The regression analysis explained 35% of the variance in Internet use. Use was directly associated with five factors: perceived usefulness, importance given to written media in searches for health information, concern for personal health, importance given to the opinions of physicians and other health professionals, and the trust placed in the information available on the site itself. This study confirms the importance of the credibility of information on the frequency of Internet use as a preferred source of information on personal health. It also shows the potentially influential role of the Internet in the development of personal knowledge of health issues.

  2. Determination of neutron radiation source on components in the decy 13 cyclotron tank

    International Nuclear Information System (INIS)

    Sunardi; Silakhuddin

    2015-01-01

    In order to design the shielding on the Decy 13 cyclotron system, a study to identify the potency of neutron radiation at the cyclotron components in the vacuum tank has been carried out. The method used is to identify the kind of components material, analyzing significant nuclear reactions producing neutron, and determining the radial distribution of the formation probability of the nuclear reaction. The results of identification show that the nuclear reaction producing neutron are Cu 65 (p,n)Zn 65 , Cu 63 (p,n)Zn 63 and Fe 56 (p,n)Co 56 . The peaks of distribution curve of the formation probability of those reactions are located on the area between 37 cm and 39 cm. (author)

  3. Determining the nature of faint X-ray sources from the ASCA Galactic center survey

    Science.gov (United States)

    Lutovinov, A. A.; Revnivtsev, M. G.; Karasev, D. I.; Shimansky, V. V.; Burenin, R. A.; Bikmaev, I. F.; Vorob'ev, V. S.; Tsygankov, S. S.; Pavlinsky, M. N.

    2015-05-01

    We present the results of the the identification of six objects from the ASCA Galactic center and Galactic plane surveys: AX J173548-3207, AX J173628-3141, AX J1739.5-2910, AX J1740.4-2856, AX J1740.5-2937, and AX J1743.9-2846. Chandra, XMM-Newton, and XRT/Swift X-ray data have been used to improve the positions of the optical counterparts to these sources. Thereafter, we have carried out a series of spectroscopic observations of the established optical counterparts at the RTT-150 telescope. Analysis of X-ray and optical spectra as well as photometric measurements in a wide wavelength range based on optical and infrared catalogs has allowed the nature of the program sources to be determined. Two X-ray objects have been detected in the error circle of AX J173628-3141: one is a coronally active G star and the other may be a symbiotic star, a red giant with an accreting white dwarf. Three sources (AX J1739.5-2910, AX J1740.5-2937, AX J1743.9-2846) have turned out to be active G-K stars, presumably RS CVn objects, one (AX J1740.4-2856) is an M dwarf, and another one (AX J173548-3207) most likely a low-mass X-ray binary in its low state. The distances and corresponding luminosities of the sources in the soft X-ray band (0.5-10 keV) have been estimated; analysis of deep INTEGRAL Galactic center observations has not revealed a statistically significant flux at energies >20 keV from any of them.

  4. Chemical characterisation and source apportionment of PM1 during massive loading at an urban location in Indo-Gangetic Plain: impact of local sources and long-range transport

    Directory of Open Access Journals (Sweden)

    Prashant Rajput

    2016-07-01

    Full Text Available This study assesses temporal variability and source contributions of PM1 (particles with aerodynamic diameter ≤ 1.0 µm samples (n=51; November 2009–February 2010 from an urban location at Kanpur (26.30°N; 80.13°E; 142 m above mean sea-level in the Indo-Gangetic Plain (IGP. A study period from November to February is preferred owing to massive loading of particulate matter in entire IGP. PM1 varies from 18 to 348 (Avg±SD: 113±72 µg m−3 in this study. A total of 11 trace metals, five major elements and four water-soluble inorganic species (WSIS have been measured. Mass fraction of total metals (∑metals=trace+major centres at 18±14 %, of which nearly 15 % is contributed by major elements. Furthermore, ∑WSIS contributes about 26 % to PM1 mass concentration. Abundance pattern among assessed WSIS in this study follows the order: ≈> > Cl−. The K-to-PM1 mass fraction (Avg: 2 % in conjunction with air-mass back trajectories (AMBT indicates that the prevailing north-westerly winds transport biomass burning derived pollutants from upwind IGP. A recent version of positive matrix factorisation (PMF 5.0 has been utilised to quantify the contribution of fine-mode aerosols from various sources. The contribution from each source is highly variable and shows a strong dependence on AMBT. Events with predominant contribution from biomass burning emission (>70 % indicate origin of air-masses from source region upwind in IGP. One of the most interesting features of our study relates to the observation that secondary aerosols (contributing as high as ~60 % to PM1 loading are predominantly derived from stationary combustion sources (/ ratio: 0.30±0.23. Thus, our study highlights a high concentration of PM1 loading and atmospheric fog prevalent during wintertime can have a severe impact on atmospheric chemistry in the air-shed of IGP.

  5. Determination of geochemical and anthropogenic uranium sources in soil and tailing

    International Nuclear Information System (INIS)

    Stojanovic, M.; Potpara, D.; Tesmanovic, L.

    2002-01-01

    The origin of uranium in soil (geochemical or anthropogenic) influences the degree of its accessibility to plants. Uranium originating from the geochemical sources is much less, if not quite inaccessible to plants. On the other hand uranium accumulated in soil as a result of anthropogenic activity (use of phosphate fertilisers, dissemination of flying ash from the thermal power plants, dissemination of mining wastes, disposal of nuclear waste and use of ammunition produced from depleted uranium) is most often present in forms much more accessible to plants. The aim of this work was to determine the efficiency of different methods of uranium extraction from soil (used to determine the 'mobile' and accessible contents) which could give the answer on the level of its accessibility to plants, and to determine uranium distribution in various chemical fractions by the method of fractional extraction.The applied method of fractional extraction is based on the idea that all metals form bonds of different strength with the solid phase of soil and such bonds can be completely broken under the effect of reagents such as: 0.1M CaCl 2 (pH - 7.0) for extraction of water-soluble and alternately adsorbed forms of metals; 1M CH 3 COONa (pH - 5.0) for the extraction of specifically adsorbed forms of metals bonded to carbonates; 0.04M hydroxylamine hydrochloride in 25% CH 3 COOH (pH - 3.0) for extraction of metals bonded to Fe and Mn oxide; 0.02M HNO 3 in 30% H 2 O 2 for metals bonded to organic matter. Structurally bonded forms of metals in silicates are determined from the difference of the total uranium content and sum of the metal quantity from the first four fractions. Determination of uranium content in samples was performed by the fluorimetric method. (author)

  6. Air-kerma strength determination of a new directional 103Pd source

    International Nuclear Information System (INIS)

    Aima, Manik; Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S.

    2015-01-01

    Purpose: A new directional 103 Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing 103 Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active 103 Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S K ) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S K to a well-type ionization chamber. Methods: S K measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S K from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S K with the presence of gold fluorescent energy lines. In addition to S K measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S K values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S K of four CivaDots with reproducibilities within

  7. Air-kerma strength determination of a new directional {sup 103}Pd source

    Energy Technology Data Exchange (ETDEWEB)

    Aima, Manik, E-mail: aima@wisc.edu; Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S. [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2015-12-15

    Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S

  8. Determinants of the accuracy of nursing diagnoses: influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills.

    Science.gov (United States)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used the following questionnaires: (a) knowledge inventory, (b) California Critical Thinking Disposition Inventory, and (c) Health Science Reasoning Test (HSRT). The use of knowledge sources had very little influence on the accuracy of nursing diagnoses. Accuracy was significantly related to the analysis domain of the HSRT. Students were unable to operationalize knowledge sources to derive accurate diagnoses and did not effectively use reasoning skills. Copyright 2010 Elsevier Inc. All rights reserved.

  9. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  10. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J, E-mail: z.lu@sheffield.ac.uk, E-mail: s.j.matcher@sheffield.ac.uk [Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ (United Kingdom)

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  11. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    International Nuclear Information System (INIS)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J

    2011-01-01

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  12. [Determination of sulfur in plant using a high-resolution continuum source atomic absorption spectrometer].

    Science.gov (United States)

    Wang, Yu; Li, Jia-xi

    2009-05-01

    A method for the analysis of sulfur (S) in plant by molecular absorption of carbon monosulfide (CS) using a high-resolution continuum source atomic absorption spectrometer (CS AAS) with a fuel-rich air/acetylene flame has been devised. The strong CS absorption band was found around 258 nm. The half-widths of some absorption bands were of the order of picometers, the same as the common atomic absorption lines. The experimental procedure in this study provided optimized instrumental conditions (the ratio of acetylene to air, the burner height) and parameters, and researched the spectral interferences and chemical interferences. The influence of the organic solvents on the CS absorption signals and the different digestion procedures for the determination of sulfur were also investigated. The limit of detection achieved for sulfur was 14 mg x L(-1), using the CS wavelength of 257. 961 nm and a measurement time of 3 s. The accuracy and precision were verified by analysis of two plant standard reference materials. The major applications of this method have been used for the determination of sulfur in plant materials, such as leaves. Compared to the others, this method for the analysis of sulfur is rapid, easy and simple for sulfur determination in plant.

  13. Determination of impurity elements in steel by spark source mass spectrometry using powdered salts

    International Nuclear Information System (INIS)

    Saito, Morimasa; Sudo, Emiko

    1975-01-01

    Determination of impurity elements in steel by speak source mass spectrometry using powdered salts sample electrode was studied. The instrument used in this study was an AEI MS-7 mass spectrograph and the ion detector was Ilford Q2 photograph. Sample, (0.5--1) gram, was dissolved in hydrochloric acid (1 : 1) or nitric acid (1 : 1) together with yttrium of 1 microgram as the internal standard and then the solution was evaporated to dryness without baking. The salt residues were dried at 70 0 C for 30 minutes under vacuum. They were mixed with an equal amount of graphite powder for 5 minutes in a mixer mill, and then pressed into electrodes. When the relative sensitivity coefficient (Fe=1) was determined by using NBS 460 series standard samples, the results obtained by the proposed method for elements of Mo, Sn, Cu, Cr, Co, Ni, Mn, V, P, Si, and B were in good agreement with those obtained by the conventional method using solid sample electrodes (the solid method) and the precision of this method for 11 elements mentioned above was about 10% better than those of the solid method. However, both the accuracy and precision for elements of Nb, Ti, S and W were not good. This method was applied to the determination of impurities in NBS stainless steel and others. The relative standard deviations were within 20%. (auth.)

  14. Industrial location and competitiveness

    NARCIS (Netherlands)

    S. Brakman (Steven); J.H. Garretsen (Harry); J.G.M. van Marrewijk (Charles)

    2006-01-01

    textabstractThe interaction between the extent of location advantages and the intensity of firm competition relative to the size of the market jointly determines the location of industrial activity. Technology, factor endowments, geography, and scale economies are influential for determining

  15. Utility of the tetrophosmine-99mTc in the determination of malignant tumours located in the muscle-skeletal system, preliminary report

    International Nuclear Information System (INIS)

    Garcia R, J.C.; Gonzalez, I.F.; Rico, G.; Linares, L.M.; Delgado C, E.; Baena, L.; Adame, G.; Gonzalez R, D.; Perez C, J.P.; Valencia, S.

    2005-01-01

    From its authorization by the FDA, as radiopharmaceutical to be used in studies of myocardial perfusion, multiple articles have appeared in the literature it prescribes that its validate the use of the tetrophosmine- 99m Tc in the valuation of different tumors, so much in the determination of malignancy, like in the evolution and in the response to the treatment. For that reason the objective of this protocol is to evaluate the utility of the tetrophosmine- 99m Tc in the determination of malignancy in non treated tumors located in the skeletal muscle system, in a population of 40 patients coming from the service of bony tumors of the National Center of Rehabilitation. For the time being its report the discoveries in 27 studies. (Author)

  16. Determining the source region of auroral emissions in the prenoon oval using coordinated Polar BEAR UV-imaging and DMSP particle measurements

    International Nuclear Information System (INIS)

    Newell, P.T.; Meng, C.I.; Huffman, R.E.

    1992-01-01

    The Polar Beacon Experiment and Auroral Research (Polar BEAR) satellite included the capability for imaging the dayside auroral oval in full sunlight at several wavelengths. The authors compare particle observations from the DMSP F7 satellite during dayside auroral oval crossings with approximately simultaneous Polar BEAR 1,356-angstrom images to determine the magnetospheric source region of the dayside auroral oval. The source region is determined from the Defense Meteorological Satellite Program (DMSP) particle data, according to recent work concerning the classification and identification of precipitation source regions. The close DMSP/Polar BEAR coincidences all occur when the former satellite is located between 0945 and 1,000 MLT. The authors found instances of auroral arcs mapping to each of several different regions, including the boundary plasma sheet, the low-latitude boundary layer, and the plasma mantle. However, the results indicate that about half the time the most prominent auroral arcs are located at the interfaces between distinct plasma regions, at least at the local time studied here

  17. Determination of material and its thickness for Cs-137 gamma source shielding

    International Nuclear Information System (INIS)

    Tukiman

    2008-01-01

    Its has been determined the shielding material and its thickness necessarily conducted due to every material will have different half-thickness characteristics, and by the selection a suitable material and its thickness will be obtained. Half-thickness of any material is the ability of the material at a certain thickness to absorb any radiation intensity so that the intensity becomes half of its source. Sample materials to be used are concrete, wood, and lead with their thickness varied. From experiment data and theoretical computation can be concluded that lead is the suitable material for shielding with the value of HVT for gamma radiation 0,732 cm. For wood and concrete will give half-thickness of 11,0 cm and 3,164 cm respectively. (author)

  18. Determination of discharge parameters via OES at the Linac4 H− ion source

    International Nuclear Information System (INIS)

    Briefi, S.; Fink, D.; Mattei, S.; Lettry, J.; Fantz, U.

    2016-01-01

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T e ≈ 1.2 eV, n e ≈ 1 × 10 19 m −3 , and n H /n H 2 ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients

  19. Determination of the silver content in some ancient coins using an Am-Be neutron source

    International Nuclear Information System (INIS)

    Cosma, C.; Fiat, T.; Znamizovschi, V.; Daraban, L.; Morariu, V.; Boros, D.; Alicu, D.

    1985-01-01

    The silver content of 40 Roman and Greek coins was determined using neutron activation analysis. with an M-Be thermal source. The pure silver standard had a weigth and shape similar to those of the analyzed coins. A monopchannel spectrometer with a NaI(Tl), 45x40 mm scintillator crystal was used. The coins were placed at the center of the entrance window of the crystal, the maximum measuring geometry being about 2π. A VA-5-968 scintillation probe was used, placed in a VA-H-161 lead shield in order to reduce the background of the detector. The irradiation time, cooling time and measuring time were 2 min, 20 sec and 1 min correspondingly. The ratio of counting rates for the standard material and the background was 2,5. The experimental errors were about 5% for concentrations higher than 50% and increasingly higher for lower silver concentrations

  20. Determining water use of sorghum from two-source energy balance and radiometric temperatures

    Directory of Open Access Journals (Sweden)

    J. M. Sánchez

    2011-10-01

    Full Text Available Estimates of surface actual evapotranspiration (ET can assist in predicting crop water requirements. An alternative to the traditional crop-coefficient methods are the energy balance models. The objective of this research was to show how surface temperature observations can be used, together with a two-source energy balance model, to determine crop water use throughout the different phenological stages of a crop grown. Radiometric temperatures were collected in a sorghum (Sorghum bicolor field as part of an experimental campaign carried out in Barrax, Spain, during the 2010 summer growing season. Performance of the Simplified Two-Source Energy Balance (STSEB model was evaluated by comparison of estimated ET with values measured on a weighing lysimeter. Errors of ±0.14 mm h−1 and ±1.0 mm d−1 were obtained at hourly and daily scales, respectively. Total accumulated crop water use during the campaign was underestimated by 5%. It is then shown that thermal radiometry can provide precise crop water necessities and is a promising tool for irrigation management.

  1. Sources and transport of phosphorus to rivers in California and adjacent states, U.S., as determined by SPARROW modeling

    Science.gov (United States)

    Domagalski, Joseph L.; Saleh, Dina

    2015-01-01

    The SPARROW (SPAtially Referenced Regression on Watershed attributes) model was used to simulate annual phosphorus loads and concentrations in unmonitored stream reaches in California, U.S., and portions of Nevada and Oregon. The model was calibrated using de-trended streamflow and phosphorus concentration data at 80 locations. The model explained 91% of the variability in loads and 51% of the variability in yields for a base year of 2002. Point sources, geological background, and cultivated land were significant sources. Variables used to explain delivery of phosphorus from land to water were precipitation and soil clay content. Aquatic loss of phosphorus was significant in streams of all sizes, with the greatest decay predicted in small- and intermediate-sized streams. Geological sources, including volcanic rocks and shales, were the principal control on concentrations and loads in many regions. Some localized formations such as the Monterey shale of southern California are important sources of phosphorus and may contribute to elevated stream concentrations. Many of the larger point source facilities were located in downstream areas, near the ocean, and do not affect inland streams except for a few locations. Large areas of cultivated land result in phosphorus load increases, but do not necessarily increase the loads above those of geological background in some cases because of local hydrology, which limits the potential of phosphorus transport from land to streams.

  2. Library Locations

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Carnegie Library of Pittsburgh locations including address, coordinates, phone number, square footage, and standard operating hours. The map below does not display...

  3. Sediment budgets and source determinations using fallout Cesium-137 in a semiarid rangeland watershed, Arizona, USA

    International Nuclear Information System (INIS)

    Ritchie, Jerry C.; Nearing, Mark A.; Rhoton, Fred E.

    2009-01-01

    Analysis of soil redistribution and sediment sources in semiarid and arid watersheds provides information for implementing management practices to improve rangeland conditions and reduce sediment loads to streams. The purpose of this research was to develop sediment budgets and identify potential sediment sources using 137 Cs and other soil properties in a series of small semiarid subwatersheds on the USDA ARS Walnut Gulch Experimental Watershed near Tombstone, Arizona, USA. Soils were sampled in a grid pattern on two small subwatersheds and along transects associated with soils and geomorphology on six larger subwatersheds. Soil samples were analyzed for 137 Cs and selected physical and chemical properties (i.e., bulk density, rocks, particle size, soil organic carbon). Suspended sediment samples collected at measuring flume sites on the Walnut Gulch Experimental Watershed were also analyzed for these properties. Soil redistribution measured using 137 Cs inventories for a small shrub-dominated subwatershed and a small grass-dominated subwatershed found eroding areas in these subwatersheds were losing -5.6 and -3.2 t ha -1 yr -1 , respectively; however, a sediment budget for each of these subwatersheds, including depositional areas, found net soil loss to be -4.3 t ha -1 yr -1 from the shrub-dominated subwatershed and -0.1 t ha -1 yr -1 from the grass-dominated subwatershed. Generally, the suspended sediment collected at the flumes of the six other subwatersheds was enriched in silt and clay. Using a mixing model to determine sediment source indicated that shrub-dominated subwatersheds were contributing most of the suspended sediment that was measured at the outlet flume of the Walnut Gulch Experimental Watershed. The two methodologies (sediment budgets and sediment source analyses) indicate that shrub-dominated systems provide more suspended sediment to the stream systems. The sediment budget studies also suggest that sediment yields measured at the outlet of a

  4. 75 FR 69591 - Medicaid Program; Withdrawal of Determination of Average Manufacturer Price, Multiple Source Drug...

    Science.gov (United States)

    2010-11-15

    ..., Multiple Source Drug Definition, and Upper Limits for Multiple Source Drugs AGENCY: Centers for Medicare... withdrawing the definition of ``multiple source drug'' as it was revised in the ``Medicaid Program; Multiple Source Drug Definition'' final rule published in the October 7, 2008 Federal Register. DATES: Effective...

  5. Application of AmBe source neutron irradiator for determination of inorganic elements in commercial fertilizers

    International Nuclear Information System (INIS)

    Madi Filho, Tufic; Armelim, Maria Jose Aguirre; Fulas, Paulo Marcelo Marangon; Trevizam, Anderson Ricardo; Figueira, Rubens Cesar Lopes

    2005-01-01

    The rational use of fertilizers , for the soil fertility correction, contributes to the increase of agricultural production, using the same areas previously available. The quality of products could ne improved with reduced costs. Therefore, knowledge of the chemical characteristics of the correctives used is required to streamline the application and avoid excesses or deficiencies. The studied characteristics are generally limited to the essential nutrients for the nutrition of plants and animals, e.g.: Mn, Zn, P, K, Cu and those known toxic, such as: As, Cd, Hg and Pb. Neutron activation analysis (NAA) is a highly sensitive non destructive technique, for the determination of the elemental composition in samples. It has been particularly useful in the simultaneous determination of inorganic elements in complex samples of several kinds. Several analysis methods for activation are used, such as: comparative and absolute. Commercial fertilizers were analyzed applying the absolute and comparative methods. Using the absolute method, samples were submitted to neutron flux generated by an irradiator with two Am Be sources. The obtained results were compared with those obtained by the comparative method using neutrons generated in the IEA-R1 Reactor. (author)

  6. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Science.gov (United States)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L- 1 HNO3 solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L- 1 and 36.4 mg L- 1, respectively. The repeatability of the results expressed as relative standard deviation was typically beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93-105% with the repeatability in the range of 4.1-5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg- 1), egg white (2188 ± 29 mg kg- 1), mineral water (31.0 ± 0.9 mg L- 1), white wine (260 ± 4 mg L- 1) and red wine (82 ± 2 mg L- 1), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L- 1).

  7. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata, E-mail: bgodlew@uwb.edu.pl

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L{sup −1} HNO{sub 3} solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L{sup −1} and 36.4 mg L{sup −1}, respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93–105% with the repeatability in the range of 4.1–5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg{sup −1}), egg white (2188 ± 29 mg kg{sup −1}), mineral water (31.0 ± 0.9 mg L{sup −1}), white wine (260 ± 4 mg L{sup −1}) and red wine (82 ± 2 mg L{sup −1}), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L{sup −1}). - Highlights: • HR-CS FMAS technique was used for sulfur measurement via molecular absorption of carbon monosulfide, CS. • Organic DL

  8. Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Nath, Ravinder

    2007-01-01

    Accurate determination of dose-rate constant (Λ) for interstitial brachytherapy sources emitting low-energy photons (<50 keV) has remained a challenge in radiation dosimetry because of the lack of a suitable absolute dosimeter for accurate measurement of the dose rates near these sources. Indeed, a consensus value of Λ taken as the arithmetic mean of the dose-rate constants determined by different research groups and dosimetry techniques has to be used at present for each source model in order to minimize the uncertainties associated with individual determinations of Λ. Because the dosimetric properties of a source are fundamentally determined by the characteristics of the photons emitted by the source, a new technique based on photon spectrometry was developed in this work for the determination of dose-rate constant. The photon spectrometry technique utilized a high-resolution gamma-ray spectrometer to measure source-specific photon characteristics emitted by the low-energy sources and determine their dose-rate constants based on the measured photon-energy spectra and known dose-deposition properties of mono-energetic photons in water. This technique eliminates many of the difficulties arising from detector size, the energy dependence of detector sensitivity, and the use of non-water-equivalent solid phantoms in absolute dose rate measurements. It also circumvents the uncertainties that might be associated with the source modeling in Monte Carlo simulation techniques. It was shown that the estimated overall uncertainty of the photon spectrometry technique was less than 4%, which is significantly smaller than the reported 8-10% uncertainty associated with the current thermo-luminescent dosimetry technique. In addition, the photon spectrometry technique was found to be stable and quick in Λ determination after initial setup and calibration. A dose-rate constant can be determined in less than two hours for each source. These features make it ideal to determine

  9. Pitfalls in the assessment of radioresponse as determined by tumor regression. Consideration based on the location and histologic constitution of tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Shimizu, Wakako; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2000-05-01

    To prove the following hypotheses regarding tumor shrinkage after radiotherapy. Tumors located on an outer tissue surface, e.g. esophageal tumors shrink faster than parenchymal tumors, e.g. lymph-node metastasis, because two clearance mechanisms, exfoliation and absorption, can operate in the former type of tumors whereas only absorption can function in the latter. Tumors which are being controlled do not necessarily respond completely, because tumors are constituted not only of tumor cells but also stromal tissues that are difficult to be absorbed. Long-term shrinkage patterns of a parenchymal tumor were determined by using 18 curatively irradiated hepatomas. Preoperatively irradiated thymomas (10) and lymph-node metastases (37) from head and neck cancers were examined histopathologically. Twenty-one esophageal cancers were used for intra-patient response comparison between the primary disease and the lymph-node metastases. Shrinkage patterns were generally biphasic: rapid exponential regression followed by a plateau phase. Histologically, thymomas generally consisted of predominant fibrous tissues and few remaining tumor cells. Radioresponse did not predict the presence of remaining cancer cells in the lymph nodes. Esophageal-cancer radiorespone was always higher for the primary disease than the lymph-node metastases. The location and histologic constitution of tumors must be taken into account in predicting radiocurability using radioresponse. (author)

  10. Gene Locater

    DEFF Research Database (Denmark)

    Anwar, Muhammad Zohaib; Sehar, Anoosha; Rehman, Inayat-Ur

    2012-01-01

    software's for calculating recombination frequency is mostly limited to the range and flexibility of this type of analysis. GENE LOCATER is a fully customizable program for calculating recombination frequency, written in JAVA. Through an easy-to-use interface, GENE LOCATOR allows users a high degree...... of flexibility in calculating genetic linkage and displaying linkage group. Among other features, this software enables user to identify linkage groups with output visualized graphically. The program calculates interference and coefficient of coincidence with elevated accuracy in sample datasets. AVAILABILITY...

  11. Location and determination of steps of capacitors in shunt for distribution power lines; Localizacion y determinacion de pasos de capacitores en derivacion para lineas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Pampin Vergara, Gabriela; Sarmiento Uruchurtu, Hector [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    A methodology is presented to determine the optimal location of the capacitor banks in shunt for distribution networks. The proposed tool allows knowing the bank type to install (fixed, disconnect able or of pass), as well as the electrical parameters of the feeder and the economic benefit that the banks of capacitors represent, with a minimum of input data. Its development in a spreadsheet allows the analysis of numerous alternatives in an easy way. The method is based on that the structure of the feeders of distribution is, generally, of radial type, with which, and by means of an iterative process, the optimal location of the capacitor banks in shunt is looked for. The type of bank is determined based of the demand, as well as the number of steps. The results of the analysis in feeders of the network of the central area are shown. [Spanish] Se presenta una metodologia para determinar la localizacion optima de los bancos de capacitores en derivacion en redes de distribucion. La herramienta propuesta permite conocer el tipo de banco a instalar (fijo, desconcectable o de paso), asi como los parametros electricos del alimentador y el beneficio economico que representan los bancos de capacitores, con un minimo de datos de entrada. Su desarrollo en una hoja de calculo permite el analisis de numerosas alternativas de manera facil. El metodo se basa en que la estructura de los alimentadores de distribucion es, por lo general, de tipo radial, con lo cual, y por medio de un proceso iterativo, se busca la localizacion optima de los bancos de capacitores en derivacion. Se determina el tipo de banco en funcion de la demanda, asi como el numero de pasos. Se muestran resultados del analisis en alimentadores de la red del area central.

  12. Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of 103Pd-model Pd-1

    International Nuclear Information System (INIS)

    Nath, Ravinder; Yue Ning; Roa, Eduardo

    2002-01-01

    A newly designed encapsulated 103 Pd source has been introduced (BrachySeed trade mark sign -Pd-103, also named Model Pd-1, manufactured by DRAXIMAGE Inc. and distributed by Cytogen Corp.) for interstitial brachytherapy to provide more isotropic dose distributions. In this work, the dosimetric characteristics of the 103 Pd source were measured with micro LiF TLD chips and dosimetry parameters were characterized based upon the American Association of Physicists in Medicine (AAPM) Task Group No. 43 formalism. The dose rate constant of the sources was determined to be 0.66±0.05 cGy h-1 U-1. The radial dose function was measured and was found to be similar to that of the Theragenics Model 200 103 Pd source. The anisotropy constant for the Model Pd-1 source was determined to be 1.03

  13. Physical, lifestyle, psychological, and social determinants of pain intensity, pain disability, and the number of pain locations in depressed older adults.

    Science.gov (United States)

    Hanssen, Denise J C; Naarding, Paul; Collard, Rose M; Comijs, Hannie C; Oude Voshaar, Richard C

    2014-10-01

    Late-life depression and pain more often co-occur than can be explained by chance. Determinants of pain in late-life depression are unknown, even though knowledge on possible determinants of pain in depression is important for clinical practice. Therefore, the objectives of the present study were 1) to describe pain characteristics of depressed older adults and a nondepressed comparison group, and 2) to explore physical, lifestyle, psychological, and social determinants of acute and chronic pain intensity, disability, and multisite pain in depressed older adults. Data from the Netherlands Study of Depression in Older Persons cohort, consisting of 378 depressed persons, diagnosed according to Diagnostic and Statistical Manual of Mental Disorders, 4th edition criteria, and 132 nondepressed persons aged 60 years and older, were used in a cross-sectional design. Pain characteristics were measured by the Chronic Graded Pain Scale. Multiple linear regression analyses were performed to explore the contribution of physical, lifestyle, psychological, and social determinants to outcomes pain intensity, disability, and the number of pain locations. Depressed older adults more often reported chronic pain and experienced their pain as more intense and disabling compared to nondepressed older adults. Adjusted for demographic, physical, and lifestyle characteristics, multinomial logistic regression analyses showed increased odds ratios (OR) for depression in acute pain (OR 3.010; P=0.005) and chronic pain (OR 4.544, Presearch could focus on the temporal relationship between anxiety, late-life depression, and pain. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  14. Separation of mycotoxin-containing sources in grain dust and determination of their mycotoxin potential.

    Science.gov (United States)

    Palmgren, M S; Lee, L S

    1986-01-01

    Two distinct reservoirs of mycotoxins exist in fungal-infected cereal grains--the fungal spores and the spore-free mycelium-substrate matrix. Many fungal spores are of respirable size and the mycelium-substrate matrix can be pulverized to form particles of respirable size during routine handling of grain. In order to determine the contribution of each source to the level of mycotoxin contamination of dust, we developed techniques to harvest and separate mycelium-substrate matrices from spores of fungi. Conventional quantitative chromatographic analyses of separated materials indicated that aflatoxin from Aspergillus parasiticus, norsolorinic acid from a mutant of A. parasiticus, and secalonic acid D from Penicillium oxalicum were concentrated in the mycelium-substrate matrices and not in the spores. In contrast, spores of Aspergillus niger and Aspergillus fumigatus contained significant concentrations of aurasperone C and fumigaclavine C, respectively; only negligible amounts of the toxins were detected in the mycelium-substrate matrices of these two fungi. PMID:3709472

  15. Release of radionuclides following severe accident in interim storage facility. Source term determination

    International Nuclear Information System (INIS)

    Morandi, S.; Mariani, M.; Giacobbo, F.; Covini, R.

    2006-01-01

    Among the severe accidents that can cause the release of radionuclides from an interim storage facility, with a consequent relevant radiological impact on the population, there is the impact of an aircraft on the facility. In this work, a safety assessment analysis for the case of an aircraft crash into an interim storage facility is tackled. To this aim a methodology, based upon DOE, IAEA and NUREG standard procedures and upon conservative yet realistic hypothesis, has been developed in order to evaluate the total radioactivity, source term, released to the biosphere in consequence of the impact, without recurring to the use of complicated numerical codes. The procedure consists in the identification of the accidental scenarios, in the evaluation of the consequent damage to the building structures and to the waste packages and in the determination of the total release of radionuclides through the building-atmosphere interface. The methodology here developed has been applied to the case of an aircraft crash into an interim storage facility currently under design. Results show that in case of perforation followed by a fire incident the total released activity would be greater of some orders of magnitude with respect to the case of mere perforation. (author)

  16. Determination of discharge parameters via OES at the Linac4 H{sup −} ion source

    Energy Technology Data Exchange (ETDEWEB)

    Briefi, S., E-mail: stefan.briefi@physik.uni-augsburg.de [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Fink, D.; Mattei, S.; Lettry, J. [Linac4 Ion Source Team, CERN-ABP, 1211 Geneva 23 (Switzerland); Fantz, U. [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany)

    2016-02-15

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T{sub e} ≈ 1.2 eV, n{sub e} ≈ 1 × 10{sup 19} m{sup −3}, and n{sub H}/n{sub H{sub 2}} ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients.

  17. Manganese determination om minerals by activation analysis, using the californium-252 as a neutron source

    International Nuclear Information System (INIS)

    Cardoso, Antonio

    1976-01-01

    Neutron Activation Analysis, using a Californium-252 neutron source, has been applied for the determination of manganese in ores such as pyrolusite, rodonite (manganese silicate)' and blending used in dry-batteries The favorable nuclear properties of manganese, such as high thermal neutron cross-section for the reaction 55 Mn (n.gamma) 56 Mn, high concentration of manganese in the matrix and short half - life of 56 Mn, are an ideal combination for non-destructive analysis of manganese in ores. Samples and standards of manganese dioxide were irradiated for about 20 minutes, followed by a 4 to 15 minutes decay and counted in a single channel pulse-height discrimination using a NaI(Tl) scintillation detector. Counting time was equal to 10 minutes. The interference of nuclear reactions 56 Fe(n,p) 56 Mn and 59 Co (n, α) 56 were studied, as well as problems in connection with neutron shadowing during irradiation, gamma-rays attenuation during counting and influence of granulometry of samples. One sample,was also analysed by wet-chemical method (sodium bismuthate) in order to compare results. As a whole, i t was shown that the analytical method of neutron activation for manganese in ores and blending, is a method simple, rapid and with good precision and accuracy. (author)

  18. Measurement of Dα sources for particle confinement time determination in TEXTOR

    International Nuclear Information System (INIS)

    Gray, D.S.; Boedo, J.A.; Conn, R.W.; Finken, K.H.; Mank, G.; Pospieszczyk, A.; Samm, U.

    1993-01-01

    An important quantity in the study of tokamak discharges is the global particle confinement time, defined for each ionic species i by the equation below, where N i is the total population of the species in the plasma and S i is the source rate (ionization rate) of the species: τ pi N i /(S i - dN i /dt). Of particular significance is the confinement time of the main plasma component, deuterium; here, in most cases of interest, the time derivative is negligible and the confinement time is given by N/S. The deuterium content N can be estimated from the electron content, measured by interferometry, if Z eff is known. A common method of estimating the fueling rate S is to measure the emission of D α light from recycling neutrals in the plasma boundary, since collisional-radiative modeling has shown that, for plasma conditions typical in the tokamak edge, the rate of ionization of D atoms and the rate of emission of D α photons are related by a factor that varies only weakly with electron density and temperature. This paper describes the use of a CCD video camera at TEXTOR for the purpose of spatially resolving the D α light in order to measure more accurately the total emission so that τ p can be determined reliably. (author) 5 refs., 5 figs

  19. Determination of Cr, Mn, Si, and Ni in carbon steels by optical emission spectrometry with spark source

    International Nuclear Information System (INIS)

    Garcia Gonzalez, M.A.; Pomares Alfonso, M.; Mora Lopez, L.

    1995-01-01

    Elemental composition of steels determines some important of his characteristic moreover it is necessary to obtain their quality certification. Analytical procedure has performed for determination of Cr, Mn, Si and Ni in carbon steels by optical emission spectrometry with spark source. reproducibility of results is 5-11 %. Exactitude has tested with results that have obtained by internationally recognised methods-

  20. NON-INVASIVE DETERMINATION OF THE LOCATION AND DISTRIBUTION OF FREE-PHASE DENSE NONAQUEOUS PHASE LIQUIDS (DNAPL) BY SEISMIC REFLECTION TECHNIQUES

    International Nuclear Information System (INIS)

    Michael G. Waddell; William J. Domoracki; Tom J. Temples; Jerome Eyer

    2001-01-01

    The Earth Sciences and Resources Institute, University of South Carolina is conducting a 14 month proof of concept study to determine the location and distribution of subsurface Dense Nonaqueous Phase Liquid (DNAPL) carbon tetrachloride (CCl 4 ) contamination at the 216-Z-9 crib, 200 West area, Department of Energy (DOE) Hanford Site, Washington by use of two-dimensional high resolution seismic reflection surveys and borehole geophysical data. The study makes use of recent advances in seismic reflection amplitude versus offset (AVO) technology to directly detect the presence of subsurface DNAPL. The techniques proposed are a noninvasive means towards site characterization and direct free-phase DNAPL detection. This report covers the results of Task 3 and change of scope of Tasks 4-6. Task 1 contains site evaluation and seismic modeling studies. The site evaluation consists of identifying and collecting preexisting geological and geophysical information regarding subsurface structure and the presence and quantity of DNAPL. The seismic modeling studies were undertaken to determine the likelihood that an AVO response exists and its probable manifestation. Task 2 is the design and acquisition of 2-D seismic reflection data designed to image areas of probable high concentration of DNAPL. Task 3 is the processing and interpretation of the 2-D data. Task 4, 5, and 6 were designing, acquiring, processing, and interpretation of a three dimensional seismic survey (3D) at the Z-9 crib area at 200 west area, Hanford