WorldWideScience

Sample records for source attribution measuring

  1. Greenhouse Gas Source Attribution: Measurements Modeling and Uncertainty Quantification

    Liu, Zhen [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Safta, Cosmin [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sargsyan, Khachik [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Najm, Habib N. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); van Bloemen Waanders, Bart Gustaaf [Sandia National Lab. (SNL-CA), Livermore, CA (United States); LaFranchi, Brian W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Ivey, Mark D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Schrader, Paul E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michelsen, Hope A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bambha, Ray P. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    assimilated meteorology fields, making it possible to perform a hybrid simulation, in which the Eulerian model (CMAQ) can be used to compute the initial condi- tion needed by the Lagrangian model, while the source-receptor relationships for a large state vector can be efficiently computed using the Lagrangian model in its backward mode. In ad- dition, CMAQ has a complete treatment of atmospheric chemistry of a suite of traditional air pollutants, many of which could help attribute GHGs from different sources. The inference of emissions sources using atmospheric observations is cast as a Bayesian model calibration problem, which is solved using a variety of Bayesian techniques, such as the bias-enhanced Bayesian inference algorithm, which accounts for the intrinsic model deficiency, Polynomial Chaos Expansion to accelerate model evaluation and Markov Chain Monte Carlo sampling, and Karhunen-Lo %60 eve (KL) Expansion to reduce the dimensionality of the state space. We have established an atmospheric measurement site in Livermore, CA and are collect- ing continuous measurements of CO2 , CH4 and other species that are typically co-emitted with these GHGs. Measurements of co-emitted species can assist in attributing the GHGs to different emissions sectors. Automatic calibrations using traceable standards are performed routinely for the gas-phase measurements. We are also collecting standard meteorological data at the Livermore site as well as planetary boundary height measurements using a ceilometer. The location of the measurement site is well suited to sample air transported between the San Francisco Bay area and the California Central Valley.

  2. Optimized spectroscopic scheme for enhanced precision CO measurements with applications to urban source attribution

    Nottrott, A.; Hoffnagle, J.; Farinas, A.; Rella, C.

    2014-12-01

    Carbon monoxide (CO) is an urban pollutant generated by internal combustion engines which contributes to the formation of ground level ozone (smog). CO is also an excellent tracer for emissions from mobile combustion sources. In this work we present an optimized spectroscopic sampling scheme that enables enhanced precision CO measurements. The scheme was implemented on the Picarro G2401 Cavity Ring-Down Spectroscopy (CRDS) analyzer which measures CO2, CO, CH4 and H2O at 0.2 Hz. The optimized scheme improved the raw precision of CO measurements by 40% from 5 ppb to 3 ppb. Correlations of measured CO2, CO, CH4 and H2O from an urban tower were partitioned by wind direction and combined with a concentration footprint model for source attribution. The application of a concentration footprint for source attribution has several advantages. The upwind extent of the concentration footprint for a given sensor is much larger than the flux footprint. Measurements of mean concentration at the sensor location can be used to estimate source strength from a concentration footprint, while measurements of the vertical concentration flux are necessary to determine source strength from the flux footprint. Direct measurement of vertical concentration flux requires high frequency temporal sampling and increases the cost and complexity of the measurement system.

  3. The attribute measurement technique

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  4. Source attribution of Arctic black carbon constrained by aircraft and surface measurements

    J.-W. Xu

    2017-10-01

    Full Text Available Black carbon (BC contributes to Arctic warming, yet sources of Arctic BC and their geographic contributions remain uncertain. We interpret a series of recent airborne (NETCARE 2015; PAMARCMiP 2009 and 2011 campaigns and ground-based measurements (at Alert, Barrow and Ny-Ålesund from multiple methods (thermal, laser incandescence and light absorption with the GEOS-Chem global chemical transport model and its adjoint to attribute the sources of Arctic BC. This is the first comparison with a chemical transport model of refractory BC (rBC measurements at Alert. The springtime airborne measurements performed by the NETCARE campaign in 2015 and the PAMARCMiP campaigns in 2009 and 2011 offer BC vertical profiles extending to above 6 km across the Arctic and include profiles above Arctic ground monitoring stations. Our simulations with the addition of seasonally varying domestic heating and of gas flaring emissions are consistent with ground-based measurements of BC concentrations at Alert and Barrow in winter and spring (rRMSE  < 13 % and with airborne measurements of the BC vertical profile across the Arctic (rRMSE  = 17 % except for an underestimation in the middle troposphere (500–700 hPa.Sensitivity simulations suggest that anthropogenic emissions in eastern and southern Asia have the largest effect on the Arctic BC column burden both in spring (56 % and annually (37 %, with the largest contribution in the middle troposphere (400–700 hPa. Anthropogenic emissions from northern Asia contribute considerable BC (27 % in spring and 43 % annually to the lower troposphere (below 900 hPa. Biomass burning contributes 20 % to the Arctic BC column annually.At the Arctic surface, anthropogenic emissions from northern Asia (40–45 % and eastern and southern Asia (20–40 % are the largest BC contributors in winter and spring, followed by Europe (16–36 %. Biomass burning from North America is the most important

  5. Greenhouse Gas Source Detection and Attribution in the San Francisco Bay Area of California Using a Mobile Measurement Platform

    Martien, P. T.; Guha, A.; Newman, S.; Young, A.; Bower, J.; Perkins, I.; Randall, S.; Stevenson, E.; Hilken, H.

    2017-12-01

    The Bay Area Air Quality Management District, the San Francisco Bay Area's air quality regulatory agency, has set a goal to reduce the region's greenhouse gas (GHG) emissions 80% below 1990 levels by 2050, consistent with the State of California's climate goals. Recently, the Air District's governing board adopted a 2017 Clean Air Plan advancing the agency's vision and including actions to put the region on a path to achieving the 2050 goal while also reducing air pollution and related health impacts. The Plan includes GHG rule-making efforts, policy initiatives, local government partnerships, outreach, grants and incentives, encompassing over 250 specific implementation actions across all economic sectors to effect ambitious emission reductions in the region. To support the 2017 Plan, the Air District has built a mobile measurement platform (GHG research van) to perform targeted CH4 emissions hotspot detection and source attribution. Instruments in the van measure CH4, CO2 and N2O in ambient plumes. Coincident measurements of source tracers like isotopic methane (13C - CH4), CO and ethane (C2H6) provide the capability to distinguish between biogenic, combustion-based and fossil-based fugitive methane sources. We report observations of CH4 plumes from source-specific measurements in and around facilities including a wastewater treatment plant, a composting operation, a waste-to-energy anaerobic digestion plant and a few refineries. We performed leak surveys inside several electric utility-operated facilities including a power plant and an underground natural gas storage facility. We sampled exhaust from a roadway tunnel and computed fleet-averaged automobile-related CH4 and N2O emission factors. We used tracer-to-tracer emission ratios to create chemical signatures of emissions from each sampled source category. We compare measurement-based ratios with those used to derive the regional GHG inventory. Data from these and other sources will lead to an improved

  6. Source attribution of tropospheric ozone

    Butler, T. M.

    2015-12-01

    Tropospheric ozone is a harmful pollutant with adverse effects on human health and ecosystems. As well as these effects, tropospheric ozone is also a powerful greenhouse gas, with an anthropogenic radiative forcing one quarter of that of CO2. Along with methane and atmospheric aerosol, tropospheric ozone belongs to the so-called Short Lived Climate forcing Pollutants, or SLCP. Recent work has shown that efforts to reduce concentrations of SLCP in the atmosphere have the potential to slow the rate of near-term climate change, while simultaneously improving public health and reducing crop losses. Unlike many other SLCP, tropospehric ozone is not directly emitted, but is instead influenced by two distinct sources: transport of air from the ozone-rich stratosphere; and photochemical production in the troposphere from the emitted precursors NOx (oxides of nitrogen), CO (Carbon Monoxide), and VOC (volatile organic compounds, including methane). Better understanding of the relationship between ozone production and the emissions of its precursors is essential for the development of targeted emission reduction strategies. Several modeling methods have been employed to relate the production of tropospheric ozone to emissions of its precursors; emissions perturbation, tagging, and adjoint sensitivity methods all deliver complementary information about modelled ozone production. Most studies using tagging methods have focused on attribution of tropospheric ozone production to emissions of NOx, even though perturbation methods have suggested that tropospheric ozone is also sensitive to VOC, particularly methane. In this study we describe the implementation into a global chemistry-climate model of a scheme for tagging emissions of NOx and VOC with an arbitrary number of labels, which are followed through the chemical reactions of tropospheric ozone production in order to perform attribution of tropospehric ozone to its emitted precursors. Attribution is performed to both

  7. Tropospheric Ozone Source Attribution in Southern California during Summer 2014 Based on Lidar Measurements and Model Simulations

    Granados Munoz, Maria Jose; Johnson, Matthew S.; Leblanc, Thierry

    2016-01-01

    In the past decades, significant efforts have been made to increase tropospheric ozone long-term monitoring. A large number of ground-based, airborne and space-borne instruments are currently providing valuable data to contribute to better understand tropospheric ozone budget and variability. Nonetheless, most of these instruments provide in-situ surface and column-integrated data, whereas vertically resolved measurements are still scarce. Besides ozonesondes and aircraft, lidar measurements have proven to be valuable tropospheric ozone profilers. Using the measurements from the tropospheric ozone differential absorption lidar (DIAL) located at the JPL Table Mountain Facility, California, and the GEOS-Chem and GEOS-5 model outputs, the impact of the North American monsoon on tropospheric ozone during summer 2014 is investigated. The influence of the Monsoon lightning-induced NOx will be evaluated against other sources (e.g. local anthropogenic emissions and the stratosphere) using also complementary data such as backward-trajectories analysis, coincident water vapor lidar measurements, and surface ozone in-situ measurements.

  8. A methodology for translating positional error into measures of attribute error, and combining the two error sources

    Yohay Carmel; Curtis Flather; Denis Dean

    2006-01-01

    This paper summarizes our efforts to investigate the nature, behavior, and implications of positional error and attribute error in spatiotemporal datasets. Estimating the combined influence of these errors on map analysis has been hindered by the fact that these two error types are traditionally expressed in different units (distance units, and categorical units,...

  9. Source attribution of human campylobacteriosis in Denmark.

    Boysen, L; Rosenquist, H; Larsson, J T; Nielsen, E M; Sørensen, G; Nordentoft, S; Hald, T

    2014-08-01

    SUMMARY This study assesses the contribution of different sources of human campylobacteriosis in Denmark using two different source-attribution approaches. In total, 794 non-human isolates and 406 isolates from human cases (domestic, travel related, and cases with unknown travel history) were collected. Isolates were characterized by multilocus sequence typing, flaA typing and susceptibility to antibiotics. Both models used indicate that the major burden of human campylobacteriosis in Denmark originates from the domestic broiler chicken reservoir. The second most important reservoir was found to be cattle. The Asymmetric Island model attributed 52% [95% credibility interval (CrI) 37-67] to Danish chicken, 17% (95% CrI 3-33) to imported chicken, and 17% (95% CrI 7-28) to cattle. Similarly, the Campylobacter source-attribution model apportioned 38% (95% CrI 28-47) to Danish chicken, 14% (95% CrI 10-18) to imported chicken, and 16% (95% CrI 7-25) to cattle. The addition of flaA type as an extra discriminatory typing parameter did not change the attribution of cases markedly.

  10. Measurements of volatile organic compounds at a suburban ground site (T1 in Mexico City during the MILAGRO 2006 campaign: measurement comparison, emission ratios, and source attribution

    D. M. Bon

    2011-03-01

    Full Text Available Volatile organic compound (VOC mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS quantified 12 VOC species including oxygenated VOCs (OVOCs and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of ~2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

  11. Measurements of volatile organic compounds at a suburban ground site (T1) in Mexico City during the MILAGRO 2006 campaign: Measurement comparison, emission ratios, and source attribution

    Bon, D.M.; Springston, S.; M.Ulbrich, I.; de Gouw, J. A.; Warneke, C.; Kuster, W. C.; Alexander, M. L.; Baker, A.; Beyersdorf, A. J.; Blake, D.; Fall, R.; Jimenez, J. L., Herndon, S. C.; Huey, L. G.; Knighton, W. B.; Ortega, J.; Vargas, O.

    2011-03-16

    Volatile organic compound (VOC) mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO) campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID) quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS) quantified 12 VOC species including oxygenated VOCs (OVOCs) and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS) to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS) deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG) emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of {approx}2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF) is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

  12. A Statistical Framework for Microbial Source Attribution

    Velsko, S P; Allen, J E; Cunningham, C T

    2009-04-28

    This report presents a general approach to inferring transmission and source relationships among microbial isolates from their genetic sequences. The outbreak transmission graph (also called the transmission tree or transmission network) is the fundamental structure which determines the statistical distributions relevant to source attribution. The nodes of this graph are infected individuals or aggregated sub-populations of individuals in which transmitted bacteria or viruses undergo clonal expansion, leading to a genetically heterogeneous population. Each edge of the graph represents a transmission event in which one or a small number of bacteria or virions infects another node thus increasing the size of the transmission network. Recombination and re-assortment events originate in nodes which are common to two distinct networks. In order to calculate the probability that one node was infected by another, given the observed genetic sequences of microbial isolates sampled from them, we require two fundamental probability distributions. The first is the probability of obtaining the observed mutational differences between two isolates given that they are separated by M steps in a transmission network. The second is the probability that two nodes sampled randomly from an outbreak transmission network are separated by M transmission events. We show how these distributions can be obtained from the genetic sequences of isolates obtained by sampling from past outbreaks combined with data from contact tracing studies. Realistic examples are drawn from the SARS outbreak of 2003, the FMDV outbreak in Great Britain in 2001, and HIV transmission cases. The likelihood estimators derived in this report, and the underlying probability distribution functions required to calculate them possess certain compelling general properties in the context of microbial forensics. These include the ability to quantify the significance of a sequence 'match' or &apos

  13. New paradigms for Salmonella source attribution based on microbial subtyping.

    Mughini-Gras, Lapo; Franz, Eelco; van Pelt, Wilfrid

    Microbial subtyping is the most common approach for Salmonella source attribution. Typically, attributions are computed using frequency-matching models like the Dutch and Danish models based on phenotyping data (serotyping, phage-typing, and antimicrobial resistance profiling). Herewith, we

  14. Balanced Sourcing As An Important Attribute Of Operations Strategy ...

    Balanced Sourcing As An Important Attribute Of Operations Strategy: Reality Or ... the questions “who should perform an activity or process in the value chain? ... Operations Strategy, Strategic Sourcing, Sustainable Competitive Advantage, ...

  15. New paradigms for Salmonella source attribution based on microbial subtyping.

    Mughini-Gras, Lapo; Franz, Eelco; van Pelt, Wilfrid

    2018-05-01

    Microbial subtyping is the most common approach for Salmonella source attribution. Typically, attributions are computed using frequency-matching models like the Dutch and Danish models based on phenotyping data (serotyping, phage-typing, and antimicrobial resistance profiling). Herewith, we critically review three major paradigms facing Salmonella source attribution today: (i) the use of genotyping data, particularly Multi-Locus Variable Number of Tandem Repeats Analysis (MLVA), which is replacing traditional Salmonella phenotyping beyond serotyping; (ii) the integration of case-control data into source attribution to improve risk factor identification/characterization; (iii) the investigation of non-food sources, as attributions tend to focus on foods of animal origin only. Population genetics models or simplified MLVA schemes may provide feasible options for source attribution, although there is a strong need to explore novel modelling options as we move towards whole-genome sequencing as the standard. Classical case-control studies are enhanced by incorporating source attribution results, as individuals acquiring salmonellosis from different sources have different associated risk factors. Thus, the more such analyses are performed the better Salmonella epidemiology will be understood. Reparametrizing current models allows for inclusion of sources like reptiles, the study of which improves our understanding of Salmonella epidemiology beyond food to tackle the pathogen in a more holistic way. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Salmonella source attribution based on microbial subtyping

    Barco, Lisa; Barrucci, Federica; Olsen, John Elmerdahl

    2013-01-01

    Source attribution of cases of food-borne disease represents a valuable tool for identifying and prioritizing effective food-safety interventions. Microbial subtyping is one of the most common methods to infer potential sources of human food-borne infections. So far, Salmonella microbial subtyping...... source attribution through microbial subtyping approach. It summarizes the available microbial subtyping attribution models and discusses the use of conventional phenotypic typing methods, as well as of the most commonly applied molecular typing methods in the European Union (EU) laboratories...

  17. Salmonella Source Attribution in Japan by a Microbiological Subtyping Approach

    Toyofuku, Hajime; Pires, Sara Monteiro; Hald, Tine

    2011-01-01

    In order to estimate the number of human Salmonella infections attributable to each of major animal-food source, and help identifying the best Salmonella intervention strategies, a microbial subtyping approach for source attribution was applied. We adapted a Bayesian model that attributes illnesses......-food sources, subtype-related factors, and source-related factors. National-surveillance serotyping data from 1998 to 2007 were applied to the model. Results suggested that the relative contribution of the sources to salmonellosis varied during the 10 year period, and that eggs are the most important source...... to specific sources and allows for the estimation of the differences in the ability of Salmonella subtypes and food types to result in reported salmonellosis. The number of human cases caused by different Salmonella subtypes is estimated as a function of the prevalence of these subtypes in the animal...

  18. An evolution of image source camera attribution approaches.

    Jahanirad, Mehdi; Wahab, Ainuddin Wahid Abdul; Anuar, Nor Badrul

    2016-05-01

    Camera attribution plays an important role in digital image forensics by providing the evidence and distinguishing characteristics of the origin of the digital image. It allows the forensic analyser to find the possible source camera which captured the image under investigation. However, in real-world applications, these approaches have faced many challenges due to the large set of multimedia data publicly available through photo sharing and social network sites, captured with uncontrolled conditions and undergone variety of hardware and software post-processing operations. Moreover, the legal system only accepts the forensic analysis of the digital image evidence if the applied camera attribution techniques are unbiased, reliable, nondestructive and widely accepted by the experts in the field. The aim of this paper is to investigate the evolutionary trend of image source camera attribution approaches from fundamental to practice, in particular, with the application of image processing and data mining techniques. Extracting implicit knowledge from images using intrinsic image artifacts for source camera attribution requires a structured image mining process. In this paper, we attempt to provide an introductory tutorial on the image processing pipeline, to determine the general classification of the features corresponding to different components for source camera attribution. The article also reviews techniques of the source camera attribution more comprehensively in the domain of the image forensics in conjunction with the presentation of classifying ongoing developments within the specified area. The classification of the existing source camera attribution approaches is presented based on the specific parameters, such as colour image processing pipeline, hardware- and software-related artifacts and the methods to extract such artifacts. The more recent source camera attribution approaches, which have not yet gained sufficient attention among image forensics

  19. Using Outbreak Data for Source Attribution of Human Salmonellosis and Campylobacteriosis in Europe

    Pires, Sara Monteiro; Vigre, Håkan; Makela, Pia

    2010-01-01

    % of campylobacteriosis cases were attributed to chicken. Results also revealed regional differences in the relative importance of specific sources. We assessed the method to be of limited value to attribute human campylobacteriosis due to the limited number of outbreaks. Nevertheless, the presented source attribution...... are observed at the public health endpoint and can therefore be a direct measure of attribution at the point of exposure. An analysis or summary of outbreak investigations is useful for attributing illnesses to foods, but often the implicated foods in reported outbreaks are complex foods, containing several...... food items, many of which could be the specific source of the infection. We describe a method that is able to attribute human cases to specific food items contained in complex foods. The model is based on data from investigations of Salmonella and Campylobacter outbreaks in the European Union in 2005...

  20. Complex Event Detection via Multi Source Video Attributes (Open Access)

    2013-10-03

    Complex Event Detection via Multi-Source Video Attributes Zhigang Ma† Yi Yang‡ Zhongwen Xu‡§ Shuicheng Yan Nicu Sebe† Alexander G. Hauptmann...under its International Research Centre @ Singapore Fund- ing Initiative and administered by the IDM Programme Of- fice, and the Intelligence Advanced

  1. Source attribution and mitigation strategies for air pollution in Delhi

    Kiesewetter, Gregor; Purohit, Pallav; Schoepp, Wolfgang; Liu, Jun; Amann, Markus; Bhanarkar, Anil

    2017-04-01

    Indian cities, and the megacity of Delhi in particular, have suffered from high air pollution for years. Recent observations show that ambient concentrations of fine particulate matter (PM2.5) in Delhi strongly exceed the Indian national ambient air quality standards as well as the World Health Organization's interim target levels. At the same time, India is experiencing strong urbanization, and both Delhi's emissions as well as the exposed population are growing. Therefore the question arises how PM2.5 concentrations will evolve in the future, and how they can be improved efficiently. In the past, typical responses of the Delhi government to high pollution episodes have been restrictions on motorized road traffic, on power plant operations and on construction activities. However, to design sustainable and efficient pollution mitigation measures, the contribution of different source sectors and spatial scales needs to be quantified. Here we combine the established emission calculation scheme of the Greenhouse Gas - Air Pollution Interactions and Synergies (GAINS) model with regional chemistry-transport model simulations (0.5° resolution) as well as local particle dispersion (2 × 2 km resolution) to arrive at a source attribution of ambient PM2.5 in Delhi. Calculated concentrations compare well to observations. We find that roughly 60% of total population-weighted PM2.5 originates from sources outside the national capital territory of Delhi itself. Consequently, mitigation strategies need to involve neighboring states and address the typical sources there. We discuss the likely evolution of ambient concentrations under different scenarios which assume either current emission control legislation, or application of a Clean Air Scenario foreseeing additional regulations in non-industrial sectors which are often overlooked, such as phase-out of solid fuel cookstoves, and road paving. Only in the case where the Clean Air Scenario is applied both in Delhi as well as in

  2. Bayesian Source Attribution of Salmonellosis in South Australia.

    Glass, K; Fearnley, E; Hocking, H; Raupach, J; Veitch, M; Ford, L; Kirk, M D

    2016-03-01

    Salmonellosis is a significant cause of foodborne gastroenteritis in Australia, and rates of illness have increased over recent years. We adopt a Bayesian source attribution model to estimate the contribution of different animal reservoirs to illness due to Salmonella spp. in South Australia between 2000 and 2010, together with 95% credible intervals (CrI). We excluded known travel associated cases and those of rare subtypes (fewer than 20 human cases or fewer than 10 isolates from included sources over the 11-year period), and the remaining 76% of cases were classified as sporadic or outbreak associated. Source-related parameters were included to allow for different handling and consumption practices. We attributed 35% (95% CrI: 20-49) of sporadic cases to chicken meat and 37% (95% CrI: 23-53) of sporadic cases to eggs. Of outbreak-related cases, 33% (95% CrI: 20-62) were attributed to chicken meat and 59% (95% CrI: 29-75) to eggs. A comparison of alternative model assumptions indicated that biases due to possible clustering of samples from sources had relatively minor effects on these estimates. Analysis of source-related parameters showed higher risk of illness from contaminated eggs than from contaminated chicken meat, suggesting that consumption and handling practices potentially play a bigger role in illness due to eggs, considering low Salmonella prevalence on eggs. Our results strengthen the evidence that eggs and chicken meat are important vehicles for salmonellosis in South Australia. © 2015 Society for Risk Analysis.

  3. Sulfate Aerosol in the Arctic: Source Attribution and Radiative Forcing

    Yang, Yang [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Wang, Hailong [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Smith, Steven J. [Joint Global Change Research Institute, Pacific Northwest National Laboratory, College Park MD USA; Easter, Richard C. [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Rasch, Philip J. [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA

    2018-02-08

    Source attributions of Arctic sulfate and its direct radiative effect for 2010–2014 are quantified in this study using the Community Earth System Model (CESM) equipped with an explicit sulfur source-tagging technique. Regions that have high emissions and/or are near/within the Arctic present relatively large contributions to Arctic sulfate burden, with the largest contribution from sources in East Asia (27%). East Asia and South Asia together have the largest contributions to Arctic sulfate concentrations at 9–12 km, whereas sources within or near the Arctic account largely below 2 km. For remote sources with strong emissions, their contributions to Arctic sulfate burden are primarily driven by meteorology, while contributions of sources within or near the Arctic are dominated by their emission strength. The sulfate direct radiative effect (DRE) is –0.080 W m-2 at the Arctic surface, offsetting the net warming effect from the combination of in-snow heating and DRE cooling from black carbon. East Asia, Arctic local and Russia/Belarus/Ukraine sources contribute –0.017, –0.016 and –0.014 W m-2, respectively, to Arctic sulfate DRE. A 20% reduction in anthropogenic SO2 emissions leads to a net increase of +0.013 W m-2 forcing at the Arctic surface. These results indicate that a joint reduction in BC emissions could prevent possible Arctic warming from future reductions in SO2 emissions. Sulfate DRE efficiency calculations suggest that short transport pathways together with meteorology favoring long sulfate lifetimes make certain sources more efficient in influencing the Arctic sulfate DRE.

  4. Global source attribution of sulfate aerosol and its radiative forcing

    Yang, Y.; Wang, H.; Smith, S.; Easter, R. C.; Ma, P. L.; Qian, Y.; Li, C.; Yu, H.; Rasch, P. J.

    2017-12-01

    Sulfate is an important aerosol that poses health risks and influences climate. Due to long-range atmospheric transport, local sulfate pollution could result from intercontinental influences, making domestic efforts of improving air quality inefficient. Accurate understanding of source attribution of sulfate and its radiative forcing is important for both regional air quality improvement and global climate mitigation. In this study, for the first time, a sulfur source-tagging capability is implemented in the Community Atmosphere Model (CAM5) to quantify the global source-receptor relationships of sulfate and its direct and indirect radiative forcing (DRF and IRF). Near-surface sulfate concentrations are mostly contributed by local emissions in regions with high emissions, while over regions with relatively low SO2 emissions, the near-surface sulfate is primarily attributed to non-local sources from long-range transport. The export of SO2 and sulfate from Europe contributes 20% of sulfate concentrations over North Africa, Russia and Central Asia. Sources from the Middle East account for 20% of sulfate over North Africa, Southern Africa and Central Asia in winter and autumn, and 20% over South Asia in spring. East Asia accounts for about 50% of sulfate over Southeast Asia in winter and autumn, 15% over Russia in summer, and 10% over North America in spring. South Asia contributes to 25% of sulfate over Southeast Asia in spring. Lifetime of aerosols, together with regional export, is found to determine regional air quality. The simulated global total sulfate DRF is -0.42 W m-2, with 75% contributed by anthropogenic sulfate and 25% contributed by natural sulfate. In the Southern Hemisphere tropics, dimethyl sulfide (DMS) contributes the most to the total DRF. East Asia has the largest contribution of 20-30% over the Northern Hemisphere mid- and high-latitudes. A 20% perturbation of sulfate and its precursor emissions gives a sulfate IRF of -0.44 W m-2. DMS has the

  5. The Validity of Attribute-Importance Measurement: A Review

    Ittersum, van K.; Pennings, J.M.E.; Wansink, B.; Trijp, van J.C.M.

    2007-01-01

    A critical review of the literature demonstrates a lack of validity among the ten most common methods for measuring the importance of attributes in behavioral sciences. The authors argue that one of the key determinants of this lack of validity is the multi-dimensionality of attribute importance.

  6. Online Game Addiction among Chinese College Students Measurement and Attribution.

    Zhou, Yuqiong; Li, Zhitian

    2009-01-01

    This study made an initial attempt to measure and attribute online game addiction among Chinese college students. We generated three factors of online game addiction: Control Disorder, Conflict, and Injury, as well as proposed a comprehensive model that attributed online game addiction to three groups of driving forces: environmental influences (most significant), characteristics of online games, and personal reasons.

  7. Real-time hostile attribution measurement and aggression in children.

    Yaros, Anna; Lochman, John E; Rosenbaum, Jill; Jimenez-Camargo, Luis Alberto

    2014-01-01

    Hostile attributions are an important predictor of aggression in children, but few studies have measured hostile attributions as they occur in real-time. The current study uses an interactive video racing game to measure hostile attributions while children played against a presumed peer. A sample of 75 children, ages 10-13, used nonverbal and verbal procedures to respond to ambiguous provocation by their opponent. Hostile attributions were significantly positively related to parent-rated reactive aggression, when controlling for proactive aggression. Hostile attributions using a nonverbal response procedure were negatively related to proactive aggression, when controlling for reactive aggression. Results suggest hostile attributions in real-time occur quickly and simultaneously with social interaction, which differs from the deliberative, controlled appraisals measured with vignette-based instruments. The relation between real-time hostile attributions and reactive aggression could be accounted for by the impulsive response style that is characteristic of reactive aggression, whereas children exhibiting proactive aggression may be more deliberate and intentional in their responding, resulting in a negative relation with real-time hostile attributions. These findings can be used both to identify children at risk for aggression and to enhance preventive interventions. © 2014 Wiley Periodicals, Inc.

  8. Attribute measurement systems prototypes and equipment in the United States

    Langner, D.C.; Landry, R.P.; Hsue, S.-T.; MacArthur, D.W.; Mayo, D.R.; Smith, M.K.; Nicholas, N.J.; Whiteson, R.

    2001-01-01

    Since the fall of 1997, the United States has been developing prototypical attribute verification technology for potential use by the International Atomic Energy Agency (IAEA) under the Trilateral Initiative. The first attribute measurement equipment demonstration took place in December 1997 at the Lawrence Livermore National Laboratory. This demonstration led to a series of joint Russian Federatioin/US/IAEA technical discussions that focused on attribute measurement technology that could be applied to plutonium bearing items having classified characteristics. A first prototype attribute verification system with an information barrier was demonstrated at a Trilateral Technical Workshop in June 1999 at Los Alamos. This prototype nourished further fruitful discussions between the three parties that has in turn led to the documents discussed in a previous paper. Prototype development has continued in the US, under other initiatives, using an integrated approach that includes the Trilatleral Initiative. Specifically for the Trilateral Initiative, US development has turned to some peripheral equipment that would support verifications by the IAEA. This equipment includes an authentication tool for measurement systems with information barriers and in situ probes that would facilitate inspections by reducing the need to move material out of storage locations for reverification. In this paper, we will first summarize the development of attribute verification measurement system technology in the US and then report on the status of the development of other equipment to support the Trilateral Initiative.

  9. Assessing Precision in Conventional Field Measurements of Individual Tree Attributes

    Ville Luoma

    2017-02-01

    Full Text Available Forest resource information has a hierarchical structure: individual tree attributes are summed at the plot level and then in turn, plot-level estimates are used to derive stand or large-area estimates of forest resources. Due to this hierarchy, it is imperative that individual tree attributes are measured with accuracy and precision. With the widespread use of different measurement tools, it is also important to understand the expected degree of precision associated with these measurements. The most prevalent tree attributes measured in the field are tree species, stem diameter-at-breast-height (dbh, and tree height. For dbh and height, the most commonly used measuring devices are calipers and clinometers, respectively. The aim of our study was to characterize the precision of individual tree dbh and height measurements in boreal forest conditions when using calipers and clinometers. The data consisted of 319 sample trees at a study area in Evo, southern Finland. The sample trees were measured independently by four trained mensurationists. The standard deviation in tree dbh and height measurements was 0.3 cm (1.5% and 0.5 m (2.9%, respectively. Precision was also assessed by tree species and tree size classes; however, there were no statistically significant differences between the mensurationists for dbh or height measurements. Our study offers insights into the expected precision of tree dbh and height as measured with the most commonly used devices. These results are important when using sample plot data in forest inventory applications, especially now, at a time when new tree attribute measurement techniques based on remote sensing are being developed and compared to the conventional caliper and clinometer measurements.

  10. Source Attribution of Methane Emissions in Northeastern Colorado Using Ammonia to Methane Emission Ratios

    Eilerman, S. J.; Neuman, J. A.; Peischl, J.; Aikin, K. C.; Ryerson, T. B.; Perring, A. E.; Robinson, E. S.; Holloway, M.; Trainer, M.

    2015-12-01

    Due to recent advances in extraction technology, oil and natural gas extraction and processing in the Denver-Julesburg basin has increased substantially in the past decade. Northeastern Colorado is also home to over 250 concentrated animal feeding operations (CAFOs), capable of hosting over 2 million head of ruminant livestock (cattle and sheep). Because of methane's high Global Warming Potential, quantification and attribution of methane emissions from oil and gas development and agricultural activity are important for guiding greenhouse gas emission policy. However, due to the co-location of these different sources, top-down measurements of methane are often unable to attribute emissions to a specific source or sector. In this work, we evaluate the ammonia:methane emission ratio directly downwind of CAFOs using a mobile laboratory. Several CAFOs were chosen for periodic study over a 12-month period to identify diurnal and seasonal variation in the emission ratio as well as differences due to livestock type. Using this knowledge of the agricultural ammonia:methane emission ratio, aircraft measurements of ammonia and methane over oil and gas basins in the western US during the Shale Oil and Natural Gas Nexus (SONGNEX) field campaign in March and April 2015 can be used for source attribution of methane emissions.

  11. Evaluation of an attributive measurement system in the automotive industry

    Simion, C.

    2016-08-01

    Measurement System Analysis (MSA) is a critical component for any quality improvement process. MSA is defined as an experimental and mathematical method of determining how much the variation within the measurement process contributes to overall process variability and it falls into two categories: attribute and variable. Most problematic measurement system issues come from measuring attribute data, which are usually the result of human judgment (visual inspection). Because attributive measurement systems are often used in some manufacturing processes, their assessment is important to obtain the confidence in the inspection process, to see where are the problems in order to eliminate them and to guide the process improvement. It was the aim of this paper to address such a issue presenting a case study made in a local company from the Sibiu region supplying products for the automotive industry, specifically the bag (a technical textile component, i.e. the fabric) for the airbag module. Because defects are inherent in every manufacturing process and in the field of airbag systems a minor defect can influence their performance and lives depend on the safety feature, there is a stringent visual inspection required on the defects of the bag material. The purpose of this attribute MSA was: to determine if all inspectors use the same criteria to determine “pass” from “fail” product (i.e. the fabric); to assess company inspection standards against customer's requirements; to determine how well inspectors are conforming to themselves; to identify how inspectors are conforming to a “known master,” which includes: how often operators ship defective product, how often operators dispose of acceptable product; to discover areas where training is required, procedures must be developed and standards are not available. The results were analyzed using MINITAB software with its module called Attribute Agreement Analysis. The conclusion was that the inspection process must

  12. Identification, Attribution, and Quantification of Highly Heterogeneous Methane Sources Using a Mobile Stable Isotope Analyzer

    Crosson, E.; Rella, C.; Cunningham, K.

    2012-04-01

    Despite methane's importance as a potent greenhouse gas second only to carbon dioxide in the magnitude of its contribution to global warming, natural contributions to the overall methane budget are only poorly understood. A big contributor to this gap in knowledge is the highly spatially and temporally heterogeneous nature of most natural (and for that matter anthropogenic) methane sources. This high degree of heterogeneity, where the methane emission rates can vary over many orders of magnitude on a spatial scale of meters or even centimeters, and over a temporal scale of minutes or even seconds, means that traditional methods of emissions flux estimation, such as flux chambers or eddy-covariance, are difficult or impossible to apply. In this paper we present new measurement methods that are capable of detecting, attributing, and quantifying emissions from highly heterogeneous sources. These methods take full advantage of the new class of methane concentration and stable isotope analyzers that are capable of laboratory-quality analysis from a mobile field platform in real time. In this paper we present field measurements demonstrating the real-time detection of methane 'hot spots,' attribution of the methane to a source process via real-time stable isotope analysis, and quantification of the emissions flux using mobile concentration measurements of the horizontal and vertical atmospheric dispersion, combined with atmospheric transport calculations. Although these techniques are applicable to both anthropogenic and natural methane sources, in this initial work we focus primarily on landfills and fugitive emissions from natural gas distribution, as these sources are better characterized, and because they provide a more reliable and stable source of methane for quantifying the measurement uncertainty inherent in the different methods. Implications of these new technologies and techniques are explored for the quantification of natural methane sources in a variety of

  13. Source attribution of black carbon in Arctic snow.

    Hegg, Dean A; Warren, Stephen G; Grenfell, Thomas C; Doherty, Sarah J; Larson, Timothy V; Clarke, Antony D

    2009-06-01

    Snow samples obtained at 36 sites in Alaska, Canada, Greenland, Russia, and the Arctic Ocean in early 2007 were analyzed for light-absorbing aerosol concentration together with a suite of associated chemical species. The light absorption data, interpreted as black carbon concentrations, and other chemical data were input into the EPA PMF 1.1 receptor model to explore the sources for black carbon in the snow. The analysis found four factors or sources: two distinct biomass burning sources, a pollution source, and a marine source. The first three of these were responsible for essentially all of the black carbon, with the two biomass sources (encompassing both open and closed combustion) together accounting for >90% of the black carbon.

  14. Nuclear Forensics Attributing the Source of Spent Fuel Used in an RDD Event

    Scott, M.R.

    2005-01-01

    An RDD attack against the U.S. is something America needs to prepare against. If such an event occurs the ability to quickly identify the source of the radiological material used in an RDD would aid investigators in identifying the perpetrators. Spent fuel is one of the most dangerous possible radiological sources for an RDD. In this work, a forensics methodology was developed and implemented to attribute spent fuel to a source reactor. The specific attributes determined are the spent fuel burnup, age from discharge, reactor type, and initial fuel enrichment. It is shown that by analyzing the post-event material, these attributes can be determined with enough accuracy to be useful for investigators. The burnup can be found within a 5% accuracy, enrichment with a 2% accuracy, and age with a 10% accuracy. Reactor type can be determined if specific nuclides are measured. The methodology developed was implemented into a code call NEMASYS. NEMASYS is easy to use and it takes a minimum amount of time to learn its basic functions. It will process data within a few minutes and provide detailed information about the results and conclusions

  15. Nuclear Forensics Attributing the Source of Spent Fuel Used in an RDD Event

    Scott, Mark Robert [Texas A & M Univ., College Station, TX (United States)

    2005-05-01

    An RDD attack against the U.S. is something America needs to prepare against. If such an event occurs the ability to quickly identify the source of the radiological material used in an RDD would aid investigators in identifying the perpetrators. Spent fuel is one of the most dangerous possible radiological sources for an RDD. In this work, a forensics methodology was developed and implemented to attribute spent fuel to a source reactor. The specific attributes determined are the spent fuel burnup, age from discharge, reactor type, and initial fuel enrichment. It is shown that by analyzing the post-event material, these attributes can be determined with enough accuracy to be useful for investigators. The burnup can be found within a 5% accuracy, enrichment with a 2% accuracy, and age with a 10% accuracy. Reactor type can be determined if specific nuclides are measured. The methodology developed was implemented into a code call NEMASYS. NEMASYS is easy to use and it takes a minimum amount of time to learn its basic functions. It will process data within a few minutes and provide detailed information about the results and conclusions.

  16. Use of Commericially Available Software in an Attribute Measurement System

    MacArthur, Duncan W.; Bracken, David S.; Carrillo, Louis A.; Elmont, Timothy H.; Frame, Katherine C.; Hirsch, Karen L.

    2005-01-01

    A major issue in international safeguards of nuclear materials is the ability to verify that processes and materials in nuclear facilities are consistent with declaration without revealing sensitive information. An attribute measurement system (AMS) is a non-destructive assay (NDA) system that utilizes an information barrier to protect potentially sensitive information about the measurement item. A key component is the software utilized for operator interface, data collection, analysis, and attribute determination, as well as the operating system under which they are implemented. Historically, custom software has been used almost exclusively in transparency applications, and it is unavoidable that some amount of custom software is needed. The focus of this paper is to explore the extent to which commercially available software may be used and the relative merits.

  17. Inferring source attribution from a multiyear multisource data set of Salmonella in Minnesota.

    Ahlstrom, C; Muellner, P; Spencer, S E F; Hong, S; Saupe, A; Rovira, A; Hedberg, C; Perez, A; Muellner, U; Alvarez, J

    2017-12-01

    Salmonella enterica is a global health concern because of its widespread association with foodborne illness. Bayesian models have been developed to attribute the burden of human salmonellosis to specific sources with the ultimate objective of prioritizing intervention strategies. Important considerations of source attribution models include the evaluation of the quality of input data, assessment of whether attribution results logically reflect the data trends and identification of patterns within the data that might explain the detailed contribution of different sources to the disease burden. Here, more than 12,000 non-typhoidal Salmonella isolates from human, bovine, porcine, chicken and turkey sources that originated in Minnesota were analysed. A modified Bayesian source attribution model (available in a dedicated R package), accounting for non-sampled sources of infection, attributed 4,672 human cases to sources assessed here. Most (60%) cases were attributed to chicken, although there was a spike in cases attributed to a non-sampled source in the second half of the study period. Molecular epidemiological analysis methods were used to supplement risk modelling, and a visual attribution application was developed to facilitate data exploration and comprehension of the large multiyear data set assessed here. A large amount of within-source diversity and low similarity between sources was observed, and visual exploration of data provided clues into variations driving the attribution modelling results. Results from this pillared approach provided first attribution estimates for Salmonella in Minnesota and offer an understanding of current data gaps as well as key pathogen population features, such as serotype frequency, similarity and diversity across the sources. Results here will be used to inform policy and management strategies ultimately intended to prevent and control Salmonella infection in the state. © 2017 Blackwell Verlag GmbH.

  18. Attributing human salmonellosis and campylobacteriosis to food, animal and environmental sources

    Pires, Sara Monteiro

    to the responsible sources, compare methods and results, and make recommendations on which approach to choose to answer specific risk management questions. The work is based on six manuscripts. In the first manuscript, concepts and terminology on source attribution are presented, and the remaining manuscripts...... recommendations on how to choose one or more source attribution methods to address different risk management problems. For this purpose, a “source attribution tool-box” based on the experiences from this PhD was developed....... sources of the pathogen and estimate the relative contribution of each source to the burden of human disease. A variety of methods to attribute human illness to specific sources is available, including microbial subtyping, comparative exposure assessment, analysis of studies of sporadic infections...

  19. Attributes measurements by calorimetry in 15 to 30 minutes

    Fiarman, S.; Perry, R.B.

    1987-01-01

    An analysis of the early portion of the power-history data collected with both of the IAEA's air-cooled bulk calorimeters has demonstrated that such calorimeters can measure the power from preheated containers of plutonium oxide with an accuracy of 2 to 5% in 15 to 30 minutes. Material accountancy at plutonium facilities has a need for such a capability for measurement of Pu scrap. Also, the International Atomic Energy Agency (IAEA) could use just two calorimeters and a gamma-ray assay system for reliable variables and attributes measurements of plutonium mass during a two-day physical-inventory verification (PIV) at a mixed-oxide (MOX) fuel-fabrication facility. The assay results would be free of the concerns about sample moisture, impurities, and geometry that previously have limited the accuracy of assays based on neutron measurements

  20. Instrumental measurement of beer taste attributes using an electronic tongue

    Rudnitskaya, Alisa; Polshin, Evgeny; Kirsanov, Dmitry; Lammertyn, Jeroen; Nicolai, Bart; Saison, Daan; Delvaux, Freddy R.; Delvaux, Filip; Legin, Andrey

    2009-01-01

    The present study deals with the evaluation of the electronic tongue multisensor system as an analytical tool for the rapid assessment of taste and flavour of beer. Fifty samples of Belgian and Dutch beers of different types (lager beers, ales, wheat beers, etc.), which were characterized with respect to the sensory properties, were measured using the electronic tongue (ET) based on potentiometric chemical sensors developed in Laboratory of Chemical Sensors of St. Petersburg University. The analysis of the sensory data and the calculation of the compromise average scores was made using STATIS. The beer samples were discriminated using both sensory panel and ET data based on PCA, and both data sets were compared using Canonical Correlation Analysis. The ET data were related to the sensory beer attributes using Partial Least Square regression for each attribute separately. Validation was done based on a test set comprising one-third of all samples. The ET was capable of predicting with good precision 20 sensory attributes of beer including such as bitter, sweet, sour, fruity, caramel, artificial, burnt, intensity and body.

  1. Instrumental measurement of beer taste attributes using an electronic tongue.

    Rudnitskaya, Alisa; Polshin, Evgeny; Kirsanov, Dmitry; Lammertyn, Jeroen; Nicolai, Bart; Saison, Daan; Delvaux, Freddy R; Delvaux, Filip; Legin, Andrey

    2009-07-30

    The present study deals with the evaluation of the electronic tongue multisensor system as an analytical tool for the rapid assessment of taste and flavour of beer. Fifty samples of Belgian and Dutch beers of different types (lager beers, ales, wheat beers, etc.), which were characterized with respect to the sensory properties, were measured using the electronic tongue (ET) based on potentiometric chemical sensors developed in Laboratory of Chemical Sensors of St. Petersburg University. The analysis of the sensory data and the calculation of the compromise average scores was made using STATIS. The beer samples were discriminated using both sensory panel and ET data based on PCA, and both data sets were compared using Canonical Correlation Analysis. The ET data were related to the sensory beer attributes using Partial Least Square regression for each attribute separately. Validation was done based on a test set comprising one-third of all samples. The ET was capable of predicting with good precision 20 sensory attributes of beer including such as bitter, sweet, sour, fruity, caramel, artificial, burnt, intensity and body.

  2. Instrumental measurement of beer taste attributes using an electronic tongue

    Rudnitskaya, Alisa, E-mail: alisa.rudnitskaya@gmail.com [Chemistry Department, University of Aveiro, Aveiro (Portugal); Laboratory of Chemical Sensors, Chemistry Department, St. Petersburg University, St. Petersburg (Russian Federation); Polshin, Evgeny [Laboratory of Chemical Sensors, Chemistry Department, St. Petersburg University, St. Petersburg (Russian Federation); BIOSYST/MeBioS, Catholic University of Leuven, W. De Croylaan 42, B-3001 Leuven (Belgium); Kirsanov, Dmitry [Laboratory of Chemical Sensors, Chemistry Department, St. Petersburg University, St. Petersburg (Russian Federation); Lammertyn, Jeroen; Nicolai, Bart [BIOSYST/MeBioS, Catholic University of Leuven, W. De Croylaan 42, B-3001 Leuven (Belgium); Saison, Daan; Delvaux, Freddy R.; Delvaux, Filip [Centre for Malting and Brewing Sciences, Katholieke Universiteit Leuven, Heverelee (Belgium); Legin, Andrey [Laboratory of Chemical Sensors, Chemistry Department, St. Petersburg University, St. Petersburg (Russian Federation)

    2009-07-30

    The present study deals with the evaluation of the electronic tongue multisensor system as an analytical tool for the rapid assessment of taste and flavour of beer. Fifty samples of Belgian and Dutch beers of different types (lager beers, ales, wheat beers, etc.), which were characterized with respect to the sensory properties, were measured using the electronic tongue (ET) based on potentiometric chemical sensors developed in Laboratory of Chemical Sensors of St. Petersburg University. The analysis of the sensory data and the calculation of the compromise average scores was made using STATIS. The beer samples were discriminated using both sensory panel and ET data based on PCA, and both data sets were compared using Canonical Correlation Analysis. The ET data were related to the sensory beer attributes using Partial Least Square regression for each attribute separately. Validation was done based on a test set comprising one-third of all samples. The ET was capable of predicting with good precision 20 sensory attributes of beer including such as bitter, sweet, sour, fruity, caramel, artificial, burnt, intensity and body.

  3. Photon sources for absorptiometric measurements

    Witt, R.M.; Sandrik, J.M.; Cameron, J.R.

    1976-01-01

    Photon absorptiometry is defined and the requirements of photon sources for these measurements are described. Both x-ray tubes and radionuclide sources are discussed, including the advantages of each in absorptiometric systems

  4. Attributing human foodborne illness to food sources and water in Latin America and the Caribbean using data from outbreak investigations

    Pires, Sara Monteiro; Vieira, Antonio; Perez, Enrique

    2012-01-01

    &C). Foods implicated in outbreaks were classified by their ingredients as simple foods (i.e. belonging to one single food category), or complex foods (i.e. belonging to multiple food categories). For each agent, the data from simple-food outbreaks were summarized, and the proportion of outbreaks caused...... by each category was used to define the probability that an outbreak was caused by a source. For the calculation of the number of outbreaks attributed to each source, simple-food outbreaks were attributed to the single food category in question, and complex-food outbreaks were partitioned to each category......Foodborne pathogens are responsible for an increasing burden of disease worldwide. Knowledge on the contribution of different food sources and water for disease is essential to prioritize food safety interventions and implement appropriate control measures. Source attribution using outbreak data...

  5. Authorship attribution of source code by using back propagation neural network based on particle swarm optimization.

    Yang, Xinyu; Xu, Guoai; Li, Qi; Guo, Yanhui; Zhang, Miao

    2017-01-01

    Authorship attribution is to identify the most likely author of a given sample among a set of candidate known authors. It can be not only applied to discover the original author of plain text, such as novels, blogs, emails, posts etc., but also used to identify source code programmers. Authorship attribution of source code is required in diverse applications, ranging from malicious code tracking to solving authorship dispute or software plagiarism detection. This paper aims to propose a new method to identify the programmer of Java source code samples with a higher accuracy. To this end, it first introduces back propagation (BP) neural network based on particle swarm optimization (PSO) into authorship attribution of source code. It begins by computing a set of defined feature metrics, including lexical and layout metrics, structure and syntax metrics, totally 19 dimensions. Then these metrics are input to neural network for supervised learning, the weights of which are output by PSO and BP hybrid algorithm. The effectiveness of the proposed method is evaluated on a collected dataset with 3,022 Java files belong to 40 authors. Experiment results show that the proposed method achieves 91.060% accuracy. And a comparison with previous work on authorship attribution of source code for Java language illustrates that this proposed method outperforms others overall, also with an acceptable overhead.

  6. The Prevalence and Quality of Source Attribution in Middle and High School Science Papers

    Vieyra, Michelle; Weaver, Kari

    2016-01-01

    Plagiarism is a commonly cited problem in higher education, especially in scientific writing and assignments for science courses. Students may not intentionally plagiarize, but may instead be confused about what proper source attribution entails. Much of this confusion likely stems from high school, either from lack of or inconsistent instruction…

  7. A content analysis of depression-related discourses on Sina Weibo: attribution, efficacy, and information sources.

    Pan, Jiabao; Liu, Bingjie; Kreps, Gary L

    2018-06-20

    Depression is a mood disorder that may lead to severe outcomes including mental breakdown, self-injury, and suicide. Potential causes of depression include genetic, sociocultural, and individual-level factors. However, public understandings of depression guided by a complex interplay of media and other societal discourses might not be congruent with the scientific knowledge. Misunderstandings of depression can lead to under-treatment and stigmatization of depression. Against this backdrop, this study aims to achieve a holistic understanding of the patterns and dynamics in discourses about depression from various information sources in China by looking at related posts on social media. A content analysis was conducted with 902 posts about depression randomly selected within a three-year period (2014 to 2016) on the mainstream social media platform in China, Sina Weibo. Posts were analyzed with a focus on attributions of and solutions to depression, attitudes towards depression, and efficacy indicated by the posts across various information sources. Results suggested that depression was most often attributed to individual-level factors. Across all the sources, individual-level attributions were often adopted by state-owned media whereas health and academic experts and organizations most often mentioned biological causes of depression. Citizen journalists and unofficial social groups tended to make societal-level attributions. Overall, traditional media posts suggested the lowest efficacy in coping with depression and the most severe negative outcomes as compared with other sources. The dominance of individual-level attributions and solutions regarding depression on Chinese social media on one hand manifests the public's limited understanding of depression and on the other hand, may further constrain adoption of scientific explanations about depression and exacerbate stigmatization towards depressed individuals. Mass media's posts centered on description of severe

  8. Attribution of the French human Salmonellosis cases to the main food-sources according to the type of surveillance data.

    David, J M; Sanders, P; Bemrah, N; Granier, S A; Denis, M; Weill, F-X; Guillemot, D; Watier, L

    2013-05-15

    Salmonella are the most common bacterial cause of foodborne infections in France and ubiquitous pathogens present in many animal productions. Assessing the relative contribution of the different food-animal sources to the burden of human cases is a key step towards the conception, prioritization and assessment of efficient control policy measures. For this purpose, we considered a Bayesian microbial subtyping attribution approach based on a previous published model (Hald et al., 2004). It requires quality integrated data on human cases and on the contamination of their food sources, per serotype and microbial subtype, which were retrieved from the French integrated surveillance system for Salmonella. The quality of the data available for such an approach is an issue for many countries in which the surveillance system has not been designed for this purpose. In France, the sources are monitored simultaneously by an active, regulation-based surveillance system that produces representative prevalence data (as ideally required for the approach) and a passive system relying on voluntary laboratories that produces data not meeting the standards set by Hald et al. (2004) but covering a broader range of sources. These data allowed us to study the impact of data quality on the attribution results, globally and focusing on specific features of the data (number of sources and contamination indicator). The microbial subtyping attribution model was run using an adapted parameterization previously proposed (David et al., 2012). A total of 9076 domestic sporadic cases were included in the analyses as well as 9 sources among which 5 were common to the active and the passive datasets. The greatest impact on the attribution results was observed for the number of sources. Thus, especially in the absence of data on imported products, the attribution estimates presented here should be considered with caution. The results were comparable for both types of surveillance, leading to the

  9. Comparing different types of source memory attributes in dementia of Alzheimer's type.

    Mammarella, Nicola; Fairfield, Beth; Di Domenico, Alberto

    2012-04-01

    Source monitoring (SM) refers to our ability to discriminate between memories from different sources. Twenty healthy high-cognitive functioning older adults, 20 healthy low-cognitive functioning older adults, and 20 older adults with dementia of Alzheimer's type (DAT) were asked to perform a series of SM tasks that varied in terms of the to-be-remembered source attribute (perceptual, spatial, temporal, semantic, social, and affective details). Results indicated that older DAT adults had greater difficulty in SM compared to the healthy control groups, especially with spatial and semantic details. Data are discussed in terms of the SM framework and suggest that poor memory for some types of source information may be considered as an important indicator of clinical memory function when assessing for the presence and severity of dementia.

  10. Practical Use of the Braking Attributes Measurements Results

    Ondruš Ján

    2017-01-01

    Full Text Available This contribution deals with issues of braking the passenger car. The measurement of braking deceleration of the vehicle Kia Cee´d 1,6 16 V was carried out by an optical device Correvit system. The measurement was carried out on the airport of the village of Rosina located close to Zilina. 10 drivers of different age, praxis, and kilometers driven participated in the measurement. The measured process was the vehicle full braking with the service brake of the initial speed of approximately 50 km.h-1. Each of the drivers had 10 attempts. In the closure of this contribution the results of the performed measurements, their evaluation and comparison are presented. Practical result from the contribution is mainly the measurement set of braking deceleration of the respective vehicle during intensive braking.

  11. Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

    Mirjankar, Nikhil S.; Fraga, Carlos G.; Carman, April J.; Moran, James J.

    2016-01-08

    Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to

  12. Source attribution of light-absorbing impurities in seasonal snow across northern China

    Zhang, R.; Hegg, D. A.; Huang, J.; Fu, Q.

    2013-01-01

    Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of light-absorbing impurities (LAI), including all particles that absorb light in the 650-700 nm wavelength interval. The LAI, together with 14 other analytes, are used as input to a positive matrix factorization (PMF) receptor model to explore the sources of the LAI in the snow. The PMF analysis for the LAI sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured snow light absorption: a soil dust source, an industrial pollution source, and a biomass and biofuels burning source. Soil dust was the main source of the LAI, accounting for ~ 53% of the LAI on average.

  13. Source attribution of insoluble light-absorbing particles in seasonal snow across northern China

    Zhang, R.; Hegg, D. A.; Huang, J.; Fu, Q.

    2013-06-01

    Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of insoluble light-absorbing particles (ILAP), including all particles that absorb light in the 650-700 nm wavelength interval. The ILAP, together with 14 other analytes, are used as input to a positive matrix factorization (PMF) receptor model to explore the sources of ILAP in the snow. The PMF analysis for ILAP sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured light absorption of snow: a soil dust source, an industrial pollution source, and a biomass and / or biofuel burning source. Soil dust was the main source of the ILAP, accounting for ~53% of ILAP on average.

  14. Molecular Approaches to Understanding Transmission and Source Attribution in Nontyphoidal Salmonella and Their Application in Africa.

    Mather, Alison E; Vaughan, Timothy G; French, Nigel P

    2015-11-01

    Nontyphoidal Salmonella (NTS) is a frequent cause of diarrhea around the world, yet in many African countries it is more commonly associated with invasive bacterial disease. Various source attribution models have been developed that utilize microbial subtyping data to assign cases of human NTS infection to different animal populations and foods of animal origin. Advances in molecular microbial subtyping approaches, in particular whole-genome sequencing, provide higher resolution data with which to investigate these sources. In this review, we provide updates on the source attribution models developed for Salmonella, and examine the application of whole-genome sequencing data combined with evolutionary modeling to investigate the putative sources and transmission pathways of NTS, with a focus on the epidemiology of NTS in Africa. This is essential information to decide where, what, and how control strategies might be applied most effectively. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. Identification of Multiple Subtypes of Campylobacter jejuni in Chicken Meat and the Impact on Source Attribution

    John A. Hudson

    2013-09-01

    Full Text Available Most source attribution studies for Campylobacter use subtyping data based on single isolates from foods and environmental sources in an attempt to draw epidemiological inferences. It has been suggested that subtyping only one Campylobacter isolate per chicken carcass incurs a risk of failing to recognise the presence of clinically relevant, but numerically infrequent, subtypes. To investigate this, between 21 and 25 Campylobacter jejuni isolates from each of ten retail chicken carcasses were subtyped by pulsed-field gel electrophoresis (PFGE using the two restriction enzymes SmaI and KpnI. Among the 227 isolates, thirteen subtypes were identified, the most frequently occurring subtype being isolated from three carcasses. Six carcasses carried a single subtype, three carcasses carried two subtypes each and one carcass carried three subtypes. Some subtypes carried by an individual carcass were shown to be potentially clonally related. Comparison of C. jejuni subtypes from chickens with isolate subtypes from human clinical cases (n = 1248 revealed seven of the thirteen chicken subtypes were indistinguishable from human cases. None of the numerically minor chicken subtypes were identified in the human data. Therefore, typing only one Campylobacter isolate from individual chicken carcasses may be adequate to inform Campylobacter source attribution.

  16. Source attribution of black carbon and its direct radiative forcing in China

    Yang, Yang; Wang, Hailong; Ma, Po-Lun; Rasch, Philip J.; Smith, Steven J.

    2017-01-01

    The source attributions for mass concentration, haze formation, transport and direct radiative forcing of black carbon (BC) in various regions of China are quantified in this study using the Community Earth System Model (CESM) with a source-tagging technique. Anthropogenic emissions are from the Community Emissions Data System that is newly developed for the Coupled Model Intercomparison Project Phase 6 (CMIP6). Over north China where the air quality is often poor, about 90 % of near-surface BC concentration is contributed by local emissions. Overall, 35 % of BC concentration over south China in winter can be attributed to emissions from north China, and 19 % comes from sources outside China in spring. For other regions in China, BC is largely contributed from nonlocal sources. We further investigated potential factors that contribute to the poor air quality in China. During polluted days, a net inflow of BC transported from nonlocal source regions associated with anomalous winds plays an important role in increasing local BC concentrations. BC-containing particles emitted from East Asia can also be transported across the Pacific. Our model results show that emissions from inside and outside China are equally important for the BC outflow from East Asia, while emissions from China account for 8 % of BC concentration and 29 % in column burden in the western United States in spring. Radiative forcing estimates show that 65 % of the annual mean BC direct radiative forcing (2.2 W m -2 ) in China results from local emissions, and the remaining 35 % is contributed by emissions outside of China. Efficiency analysis shows that a reduction in BC emissions over eastern China could have a greater benefit for the regional air quality in China, especially in the winter haze season.

  17. Development of a user-friendly interface version of the Salmonella source-attribution model

    Hald, Tine; Lund, Jan

    of travel and outbreak-related cases, also per country and subtype, ii) food-animal prevalence data per country and subtype, including the number of units tested and the number of positive units, and iii) data on the production and trade of the different food-animal sources in the EU Member States. The EFSA...... cases by subtype including data on the number of travel, domestic, unknown travel history and outbreak-related cases, also per subtype, ii) food-animal prevalence data per subtype, including the number of units tested and the number of positive units, and iii) data on the amount of the included animal...... for example in future mandates dealing with similar questions. The objective of the work described in this report was, therefore, to develop a flexible and user-friendly interface for attributing human cases of food-borne pathogens to the responsible food-animal reservoirs and/or food sources. The interface...

  18. Source attribution and credibility of health and appearance exercise advertisements: relationship with implicit and explicit attitudes and intentions.

    Berry, Tanya R; Shields, Chris

    2014-02-01

    The relationship of attributed source (commercial or nonprofit) and credibility of exercise advertisements to explicit and implicit exercise-related attitudes and intentions was examined. Male and female participants (N = 227) were randomly assigned to watch health or appearance-related advertisements and then completed an implicit attitudes task and questionnaires. Health advertisements and those attributed to a nonprofit source were rated more credible. Appearance condition participants who attributed the advertisement to a nonprofit source also rated the advertisement as more credible. Participants who rated a commercial advertisement as credible reported higher implicit instrumental attitudes. Implications for exercise promotion are discussed.

  19. Range and number-of-levels effects in derived and stated measures of attribute importance

    Verlegh, PWJ; Schifferstein, HNJ; Wittink, DR

    We study how the range of variation and the number of ttribute levels affect five measures of attribute importance: full profile conjoint estimates, ranges in attribute level attractiveness ratings. regression coefficients. graded paired comparisons. and self-reported ratings, We find that all

  20. The concordance of directly and indirectly measured built environment attributes and physical activity adoption

    O'Connor Daniel P

    2011-07-01

    Full Text Available Background Physical activity (PA adoption is essential for obesity prevention and control, yet ethnic minority women report lower levels of PA and are at higher risk for obesity and its comorbidities compared to Caucasians. Epidemiological studies and ecologic models of health behavior suggest that built environmental factors are associated with health behaviors like PA, but few studies have examined the association between built environment attribute concordance and PA, and no known studies have examined attribute concordance and PA adoption. Purpose The purpose of this study was to associate the degree of concordance between directly and indirectly measured built environment attributes with changes in PA over time among African American and Hispanic Latina women participating in a PA intervention. Method Women (N = 410 completed measures of PA at Time 1 (T1 and Time 2 (T2; environmental data collected at T1 were used to compute concordance between directly and indirectly measured built environment attributes. The association between changes in PA and the degree of concordance between each directly and indirectly measured environmental attribute was assessed using repeated measures analyses. Results There were no significant associations between built environment attribute concordance values and change in self-reported or objectively measured PA. Self-reported PA significantly increased over time (F(1,184 = 7.82, p = .006, but this increase did not vary by ethnicity or any built environment attribute concordance variable. Conclusions Built environment attribute concordance may not be associated with PA changes over time among minority women. In an effort to promote PA, investigators should clarify specific built environment attributes that are important for PA adoption and whether accurate perceptions of these attributes are necessary, particularly among the vulnerable population of minority women.

  1. Premature deaths attributed to source-specific BC emissions in six urban US regions

    Turner, Matthew D; Henze, Daven K; Capps, Shannon L; Hakami, Amir; Zhao, Shunliu; Resler, Jaroslav; Carmichael, Gregory R; Stanier, Charles O; Baek, Jaemeen; Sandu, Adrian; Russell, Armistead G; Nenes, Athanasios; Pinder, Rob W; Napelenok, Sergey L; Bash, Jesse O; Percell, Peter B; Chai, Tianfeng

    2015-01-01

    Recent studies have shown that exposure to particulate black carbon (BC) has significant adverse health effects and may be more detrimental to human health than exposure to PM 2.5 as a whole. Mobile source BC emission controls, mostly on diesel-burning vehicles, have successfully decreased mobile source BC emissions to less than half of what they were 30 years ago. Quantification of the benefits of previous emissions controls conveys the value of these regulatory actions and provides a method by which future control alternatives could be evaluated. In this study we use the adjoint of the Community Multiscale Air Quality (CMAQ) model to estimate highly-resolved spatial distributions of benefits related to emission reductions for six urban regions within the continental US. Emissions from outside each of the six chosen regions account for between 7% and 27% of the premature deaths attributed to exposure to BC within the region. While we estimate that nonroad mobile and onroad diesel emissions account for the largest number of premature deaths attributable to exposure to BC, onroad gasoline is shown to have more than double the benefit per unit emission relative to that of nonroad mobile and onroad diesel. Within the region encompassing New York City and Philadelphia, reductions in emissions from large industrial combustion sources that are not classified as EGUs (i.e., non-EGU) are estimated to have up to triple the benefits per unit emission relative to reductions to onroad diesel sectors, and provide similar benefits per unit emission to that of onroad gasoline emissions in the region. While onroad mobile emissions have been decreasing in the past 30 years and a majority of vehicle emission controls that regulate PM focus on diesel emissions, our analysis shows the most efficient target for stricter controls is actually onroad gasoline emissions. (letter)

  2. Source attribution of insoluble light-absorbing particles in seasonal snow across northern China

    R. Zhang

    2013-06-01

    Full Text Available Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of insoluble light-absorbing particles (ILAP, including all particles that absorb light in the 650–700 nm wavelength interval. The ILAP, together with 14 other analytes, are used as input to a positive matrix factorization (PMF receptor model to explore the sources of ILAP in the snow. The PMF analysis for ILAP sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured light absorption of snow: a soil dust source, an industrial pollution source, and a biomass and / or biofuel burning source. Soil dust was the main source of the ILAP, accounting for ~53% of ILAP on average.

  3. Impacts of Irradiation Sources on Quality Attributes of Low-salt Sausage during Refrigerated Storage

    Kim, Hyun-Wook; Choi, Yun-Sang

    2017-01-01

    This study was performed to investigate the impacts of irradiation sources on quality attributes of low-salt sausage during refrigerated storage. Control sausage was prepared with 1.5% sodium chloride (NaCl), whereas low-salt sausage was formulated with 0.75% NaCl (a 50% reduction; L-control). Sausage samples were vacuum-packaged, and low-sausages were irradiated with gamma-ray, electron-beam and X-ray at 5 kGy, respectively. The samples were stored at 4°C for 28 d to determine changes in quality attributes. The pH of low-salt sausages was unaffected by irradiation at 5 kGy (p>0.05). Higher redness values were found at irradiated low-salt sausages compared to control (psausage were higher than those of low-salt sausages (psausage treatments. The overall sensory acceptability score of irradiated/low-salt sausages were lower than L-control due to decreased scores for cooked meat flavor but increased radiolytic off-flavor (psausages were higher than control and L-control (psausages (psausages, and suggest that further studies should be necessary to reducing radiolytic off-flavor of irradiated/low-salt sausages. PMID:29147093

  4. Country of origin image attributes as a source of competitive advantage: study in international brazilian fashion industry

    Mariana Bassi Sutter

    2014-08-01

    Full Text Available The study sought to understand which attributes of the country of origin image are source of international competitive advantage in the context of Brazilian fashion. From the theoretical framework related to competitive advantage, country of origin image, Brazilianness and their attributes in fashion, we conducted exploratory research with a qualitative approach. The results suggest that the image of Brazil is understood by the international fashion market in accordance with the attributes of the literature. However (i in fashion, market still does not have a steady concept on the image of Brazil, (ii Brazilianness attributes in fashion can be a source of competitive advantage in international trades if they are communicated, promoted and understood by the international market; finally, (iii among the eight Brazilianness trendy attributes identified in the literature, four were highlighted as differentiators: shape and volumes, colors, prints and lifestyle.

  5. Global source attribution of sulfate concentration and direct and indirect radiative forcing

    Yang, Yang; Wang, Hailong; Smith, Steven J.; Easter, Richard; Ma, Po-Lun; Qian, Yun; Yu, Hongbin; Li, Can; Rasch, Philip J.

    2017-07-01

    The global source-receptor relationships of sulfate concentrations, and direct and indirect radiative forcing (DRF and IRF) from 16 regions/sectors for years 2010-2014 are examined in this study through utilizing a sulfur source-tagging capability implemented in the Community Earth System Model (CESM) with winds nudged to reanalysis data. Sulfate concentrations are mostly contributed by local emissions in regions with high emissions, while over regions with relatively low SO2 emissions, the near-surface sulfate concentrations are primarily attributed to non-local sources from long-range transport. Regional source efficiencies of sulfate concentrations are higher over regions with dry atmospheric conditions and less export, suggesting that lifetime of aerosols, together with regional export, is important in determining regional air quality. The simulated global total sulfate DRF is -0.42 W m-2, with -0.31 W m-2 contributed by anthropogenic sulfate and -0.11 W m-2 contributed by natural sulfate, relative to a state with no sulfur emissions. In the Southern Hemisphere tropics, dimethyl sulfide (DMS) contributes 17-84 % to the total DRF. East Asia has the largest contribution of 20-30 % over the Northern Hemisphere mid- and high latitudes. A 20 % perturbation of sulfate and its precursor emissions gives a sulfate incremental IRF of -0.44 W m-2. DMS has the largest contribution, explaining -0.23 W m-2 of the global sulfate incremental IRF. Incremental IRF over regions in the Southern Hemisphere with low background aerosols is more sensitive to emission perturbation than that over the polluted Northern Hemisphere.

  6. Investigating microearthquake finite source attributes with IRIS Community Wavefield Demonstration Experiment in Oklahoma

    Fan, Wenyuan; McGuire, Jeffrey J.

    2018-05-01

    An earthquake rupture process can be kinematically described by rupture velocity, duration and spatial extent. These key kinematic source parameters provide important constraints on earthquake physics and rupture dynamics. In particular, core questions in earthquake science can be addressed once these properties of small earthquakes are well resolved. However, these parameters of small earthquakes are poorly understood, often limited by available datasets and methodologies. The IRIS Community Wavefield Experiment in Oklahoma deployed ˜350 three component nodal stations within 40 km2 for a month, offering an unprecedented opportunity to test new methodologies for resolving small earthquake finite source properties in high resolution. In this study, we demonstrate the power of the nodal dataset to resolve the variations in the seismic wavefield over the focal sphere due to the finite source attributes of a M2 earthquake within the array. The dense coverage allows us to tightly constrain rupture area using the second moment method even for such a small earthquake. The M2 earthquake was a strike-slip event and unilaterally propagated towards the surface at 90 per cent local S- wave speed (2.93 km s-1). The earthquake lasted ˜0.019 s and ruptured Lc ˜70 m by Wc ˜45 m. With the resolved rupture area, the stress-drop of the earthquake is estimated as 7.3 MPa for Mw 2.3. We demonstrate that the maximum and minimum bounds on rupture area are within a factor of two, much lower than typical stress drop uncertainty, despite a suboptimal station distribution. The rupture properties suggest that there is little difference between the M2 Oklahoma earthquake and typical large earthquakes. The new three component nodal systems have great potential for improving the resolution of studies of earthquake source properties.

  7. Aerosol Health Impact Source Attribution Studies with the CMAQ Adjoint Air Quality Model

    Turner, M. D.

    Fine particulate matter (PM2.5) is an air pollutant consisting of a mixture of solid and liquid particles suspended in the atmosphere. Knowledge of the sources and distributions of PM2.5 is important for many reasons, two of which are that PM2.5 has an adverse effect on human health and also an effect on climate change. Recent studies have suggested that health benefits resulting from a unit decrease in black carbon (BC) are four to nine times larger than benefits resulting from an equivalent change in PM2.5 mass. The goal of this thesis is to quantify the role of emissions from different sectors and different locations in governing the total health impacts, risk, and maximum individual risk of exposure to BC both nationally and regionally in the US. We develop and use the CMAQ adjoint model to quantify the role of emissions from all modeled sectors, times, and locations on premature deaths attributed to exposure to BC. From a national analysis, we find that damages resulting from anthropogenic emissions of BC are strongly correlated with population and premature death. However, we find little correlation between damages and emission magnitude, suggesting that controls on the largest emissions may not be the most efficient means of reducing damages resulting from BC emissions. Rather, the best proxy for locations with damaging BC emissions is locations where premature deaths occur. Onroad diesel and nonroad vehicle emissions are the largest contributors to premature deaths attributed to exposure to BC, while onroad gasoline emissions cause the highest deaths per amount emitted. Additionally, emissions in fall and winter contribute to more premature deaths (and more per amount emitted) than emissions in spring and summer. From a regional analysis, we find that emissions from outside each of six urban areas account for 7% to 27% of the premature deaths attributed to exposure to BC within the region. Within the region encompassing New York City and Philadelphia

  8. Global source attribution of sulfate concentration and direct and indirect radiative forcing

    Y. Yang

    2017-07-01

    Full Text Available The global source–receptor relationships of sulfate concentrations, and direct and indirect radiative forcing (DRF and IRF from 16 regions/sectors for years 2010–2014 are examined in this study through utilizing a sulfur source-tagging capability implemented in the Community Earth System Model (CESM with winds nudged to reanalysis data. Sulfate concentrations are mostly contributed by local emissions in regions with high emissions, while over regions with relatively low SO2 emissions, the near-surface sulfate concentrations are primarily attributed to non-local sources from long-range transport. Regional source efficiencies of sulfate concentrations are higher over regions with dry atmospheric conditions and less export, suggesting that lifetime of aerosols, together with regional export, is important in determining regional air quality. The simulated global total sulfate DRF is −0.42 W m−2, with −0.31 W m−2 contributed by anthropogenic sulfate and −0.11 W m−2 contributed by natural sulfate, relative to a state with no sulfur emissions. In the Southern Hemisphere tropics, dimethyl sulfide (DMS contributes 17–84 % to the total DRF. East Asia has the largest contribution of 20–30 % over the Northern Hemisphere mid- and high latitudes. A 20 % perturbation of sulfate and its precursor emissions gives a sulfate incremental IRF of −0.44 W m−2. DMS has the largest contribution, explaining −0.23 W m−2 of the global sulfate incremental IRF. Incremental IRF over regions in the Southern Hemisphere with low background aerosols is more sensitive to emission perturbation than that over the polluted Northern Hemisphere.

  9. Source attribution of Bornean air masses by back trajectory analysis during the OP3 project

    N. H. Robinson

    2011-09-01

    Full Text Available Atmospheric composition affects the radiative balance of the Earth through the creation of greenhouse gases and the formation of aerosols. The latter interact with incoming solar radiation, both directly and indirectly through their effects on cloud formation and lifetime. The tropics have a major influence on incoming sunlight however the tropical atmosphere is poorly characterised, especially outside Amazonia. The origins of air masses influencing a measurement site in a protected rainforest in Borneo, South East Asia, were assessed and the likely sources of a range of trace gases and particles were determined. This was conducted by interpreting in situ measurements made at the site in the context of ECMWF backwards air mass trajectories. Two different but complementary methods were employed to interpret the data: comparison of periods classified by cluster analysis of trajectories, and inspection of the dependence of mean measured values on geographical history of trajectories. Sources of aerosol particles, carbon monoxide and halocarbons were assessed. The likely source influences include: terrestrial organic biogenic emissions; long range transport of anthropogenic emissions; biomass burning; sulphurous emissions from marine phytoplankton, with a possible contribution from volcanoes; marine production of inorganic mineral aerosol; and marine production of halocarbons. Aerosol sub- and super-saturated water affinity was found to be dependent on source (and therefore composition, with more hygroscopic aerosol and higher numbers of cloud condensation nuclei measured in air masses of marine origin. The prevailing sector during the majority of measurements was south-easterly, which is from the direction of the coast closest to the site, with a significant influence inland from the south-west. This analysis shows that marine and terrestrial air masses have different dominant chemical sources. Comparison with the AMAZE-08 project in the Amazon

  10. Let another praise you? The effects of source and attributional content on responses to group-directed praise.

    Rabinovich, Anna; Morton, Thomas A; Crook, Michael; Travers, Claire

    2012-12-01

    Not all types of praise may be equally stimulating. Instead, positive feedback carries different meaning depending on the source that delivers it and the attributions for success that it contains. In the present study, source (in-group vs. out-group) of praise and its content (attributing success to internal vs. external causes) were experimentally manipulated. The results revealed that there was a significant interaction between source and content of praise on performance in a praise-related task. As predicted, participants exposed to out-group praise were motivated by external attributions for success rather than by internal attributions. Conversely, when praise originated from an in-group source, the attributional content of praise did not affect performance. This effect of source and content of praise on relevant behaviour was mediated by willingness to protect group image. Thus, responses to praise are contingent on what it implies about group success--corresponding to patterns demonstrated in previous work on group-directed criticism. ©2012 The British Psychological Society.

  11. The use of Pb, Sr, and Hg isotopes in Great Lakes precipitation as a tool for pollution source attribution

    Sherman, Laura S., E-mail: lsaylors@umich.edu [University of Michigan, Department of Earth and Environmental Sciences, 1100 N. University Ave., Ann Arbor, MI 48109 (United States); Blum, Joel D. [University of Michigan, Department of Earth and Environmental Sciences, 1100 N. University Ave., Ann Arbor, MI 48109 (United States); Dvonch, J. Timothy [University of Michigan, Air Quality Laboratory, 1415 Washington Heights, Ann Arbor, MI 48109 (United States); Gratz, Lynne E. [University of Washington-Bothell, 18115 Campus Way NE, Bothell, WA 98011 (United States); Landis, Matthew S. [U.S. EPA, Office of Research and Development, Research Triangle Park, NC 27709 (United States)

    2015-01-01

    The anthropogenic emission and subsequent deposition of heavy metals including mercury (Hg) and lead (Pb) present human health and environmental concerns. Although it is known that local and regional sources of these metals contribute to deposition in the Great Lakes region, it is difficult to trace emissions from point sources to impacted sites. Recent studies suggest that metal isotope ratios may be useful for distinguishing between and tracing source emissions. We measured Pb, strontium (Sr), and Hg isotope ratios in daily precipitation samples that were collected at seven sites across the Great Lakes region between 2003 and 2007. Lead isotope ratios ({sup 207}Pb/{sup 206}Pb = 0.8062 to 0.8554) suggest that Pb deposition was influenced by coal combustion and processing of Mississippi Valley-Type Pb ore deposits. Regional differences in Sr isotope ratios ({sup 87}Sr/{sup 86}Sr = 0.70859 to 0.71155) are likely related to coal fly ash and soil dust. Mercury isotope ratios (δ{sup 202}Hg = − 1.13 to 0.13‰) also varied among the sites, likely due to regional differences in coal isotopic composition, and fractionation occurring within industrial facilities and in the atmosphere. These data represent the first combined characterization of Pb, Sr, and Hg isotope ratios in precipitation collected across the Great Lakes region. We demonstrate the utility of multiple metal isotope ratios in parallel with traditional trace element multivariate statistical modeling to enable more complete pollution source attribution. - Highlights: • We measured Pb, Sr, and Hg isotopes in precipitation from the Great Lakes region. • Pb isotopes suggest that deposition was impacted by coal combustion and metal production. • Sr isotope ratios vary regionally, likely due to soil dust and coal fly ash. • Hg isotopes vary due to fractionation occurring within facilities and the atmosphere. • Isotope results support conclusions of previous trace element receptor modeling.

  12. Developing methodologies for source attribution. Glass phase separation in Trinitite using NF{sub 3}

    Koeman, Elizabeth C.; Simonetti, Antonio [Notre Dame Univ., IN (United States). Dept. of Civil and Environmental Engineering and Earth Sciences; McNamara, Bruce K.; Smith, Frances N. [Pacific Northwest National Laboratory, Richland, WA (United States). Nuclear Chemistry and Engineering; Burns, Peter C. [Notre Dame Univ., IN (United States). Dept. of Civil and Environmental Engineering and Earth Sciences; Notre Dame Univ., IN (United States). Dept. of Chemistry and Biochemistry

    2017-08-01

    separation of silica from minerals (i.e. naturally occurring crystalline materials) and glasses (i.e. amorphous materials), leaving behind non-volatile fluorinated species and refractory phases. The results from our investigation clearly indicate that the NF{sub 3} treatment of nuclear materials is a technique that provides effective separation of bomb components from complex matrices (e.g. post-detonation samples), which will aid with rapid and accurate source attribution.

  13. Point source attribution of ambient contamination events near unconventional oil and gas development.

    Hildenbrand, Zacariah L; Mach, Phillip M; McBride, Ethan M; Dorreyatim, M Navid; Taylor, Josh T; Carlton, Doug D; Meik, Jesse M; Fontenot, Brian E; Wright, Kenneth C; Schug, Kevin A; Verbeck, Guido F

    2016-12-15

    We present an analysis of ambient benzene, toluene, and xylene isomers in the Eagle Ford shale region of southern Texas. In situ air quality measurements using membrane inlet mobile mass spectrometry revealed ambient benzene and toluene concentrations as high as 1000 and 5000 parts-per-billion, respectively, originating from specific sub-processes on unconventional oil and gas well pad sites. The detection of highly variant contamination events attributable to natural gas flaring units, condensate tanks, compressor units, and hydrogen sulfide scavengers indicates that mechanical inefficiencies, and not necessarily the inherent nature of the extraction process as a whole, result in the release of these compounds into the environment. This awareness of ongoing contamination events contributes to an enhanced knowledge of ambient volatile organic compounds on a regional scale. While these reconnaissance measurements on their own do not fully characterize the fluctuations of ambient BTEX concentrations that likely exist in the atmosphere of the Eagle Ford Shale region, they do suggest that contamination events from unconventional oil and gas development can be monitored, controlled, and reduced. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Measuring diversity in medical reports based on categorized attributes and international classification systems

    Přečková Petra

    2012-04-01

    Full Text Available Abstract Background Narrative medical reports do not use standardized terminology and often bring insufficient information for statistical processing and medical decision making. Objectives of the paper are to propose a method for measuring diversity in medical reports written in any language, to compare diversities in narrative and structured medical reports and to map attributes and terms to selected classification systems. Methods A new method based on a general concept of f-diversity is proposed for measuring diversity of medical reports in any language. The method is based on categorized attributes recorded in narrative or structured medical reports and on international classification systems. Values of categories are expressed by terms. Using SNOMED CT and ICD 10 we are mapping attributes and terms to predefined codes. We use f-diversities of Gini-Simpson and Number of Categories types to compare diversities of narrative and structured medical reports. The comparison is based on attributes selected from the Minimal Data Model for Cardiology (MDMC. Results We compared diversities of 110 Czech narrative medical reports and 1119 Czech structured medical reports. Selected categorized attributes of MDMC had mostly different numbers of categories and used different terms in narrative and structured reports. We found more than 60% of MDMC attributes in SNOMED CT. We showed that attributes in narrative medical reports had greater diversity than the same attributes in structured medical reports. Further, we replaced each value of category (term used for attributes in narrative medical reports by the closest term and the category used in MDMC for structured medical reports. We found that relative Gini-Simpson diversities in structured medical reports were significantly smaller than those in narrative medical reports except the "Allergy" attribute. Conclusions Terminology in narrative medical reports is not standardized. Therefore it is nearly

  15. Comparison of cluster-based and source-attribution methods for estimating transmission risk using large HIV sequence databases.

    Le Vu, Stéphane; Ratmann, Oliver; Delpech, Valerie; Brown, Alison E; Gill, O Noel; Tostevin, Anna; Fraser, Christophe; Volz, Erik M

    2018-06-01

    Phylogenetic clustering of HIV sequences from a random sample of patients can reveal epidemiological transmission patterns, but interpretation is hampered by limited theoretical support and statistical properties of clustering analysis remain poorly understood. Alternatively, source attribution methods allow fitting of HIV transmission models and thereby quantify aspects of disease transmission. A simulation study was conducted to assess error rates of clustering methods for detecting transmission risk factors. We modeled HIV epidemics among men having sex with men and generated phylogenies comparable to those that can be obtained from HIV surveillance data in the UK. Clustering and source attribution approaches were applied to evaluate their ability to identify patient attributes as transmission risk factors. We find that commonly used methods show a misleading association between cluster size or odds of clustering and covariates that are correlated with time since infection, regardless of their influence on transmission. Clustering methods usually have higher error rates and lower sensitivity than source attribution method for identifying transmission risk factors. But neither methods provide robust estimates of transmission risk ratios. Source attribution method can alleviate drawbacks from phylogenetic clustering but formal population genetic modeling may be required to estimate quantitative transmission risk factors. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Statistical Determination of Impact of Property Attributes for Weak Measurement Scales

    Doszyń Mariusz

    2017-12-01

    Full Text Available Many of the property attributes are measured on weak scales (nominal and ordinal scale. For example, land allocation in the development plan is measured on a nominal scale and such categories as proximity, equipment, access to means of communication, location, and soil and water conditions, are measured on an ordinal scale. The use of statistical measures appropriate for interval or quotient scales is wrong in such cases. Therefore, the article presents statistical measures that allow specifying the impact of the attributes on real estate prices, which can be used for the weaker scales, mainly for the ordinal scale. In the empirical illustration the proposed measures will be calculated by using the actual database of transaction prices.

  17. Multi-Sensor Constrained Time Varying Emissions Estimation of Black Carbon: Attributing Urban and Fire Sources Globally

    Cohen, J. B.

    2015-12-01

    The short lifetime and heterogeneous distribution of Black Carbon (BC) in the atmosphere leads to complex impacts on radiative forcing, climate, and health, and complicates analysis of its atmospheric processing and emissions. Two recent papers have estimated the global and regional emissions of BC using advanced statistical and computational methods. One used a Kalman Filter, including data from AERONET, NOAA, and other ground-based sources, to estimate global emissions of 17.8+/-5.6 Tg BC/year (with the increase attributable to East Asia, South Asia, Southeast Asia, and Eastern Europe - all regions which have had rapid urban, industrial, and economic expansion). The second additionally used remotely sensed measurements from MISR and a variance maximizing technique, uniquely quantifying fire and urban sources in Southeast Asia, as well as their large year-to-year variability over the past 12 years, leading to increases from 10% to 150%. These new emissions products, when run through our state-of-the art modelling system of chemistry, physics, transport, removal, radiation, and climate, match 140 ground stations and satellites better in both an absolute and a temporal sense. New work now further includes trace species measurements from OMI, which are used with the variance maximizing technique to constrain the types of emissions sources. Furthermore, land-use change and fire estimation products from MODIS are also included, which provide other constraints on the temporal and spatial nature of the variations of intermittent sources like fires or new permanent sources like expanded urbanization. This talk will introduce a new, top-down constrained, weekly varying BC emissions dataset, show that it produces a better fit with observations, and draw conclusions about the sources and impacts from urbanization one hand, and fires on another hand. Results specific to the Southeast and East Asia will demonstrate inter- and intra-annual variations, such as the function of

  18. What is the source of cultural differences? -- Examining the influence of thinking style on the attribution process.

    Jen, Chun-Hui; Lien, Yunn-Wen

    2010-02-01

    The present research is intended to find out whether individuals with analytic or holistic thought have different attribution processes. Cross-cultural research has suggested that East Asians, who tend to have a holistic thought pattern, differ in cognitive process from Westerners, who tend to engage in analytic thought. However, studies that found cultural difference in attribution process may have non-equivalence problems that make it hard to interpret the causal relationship between thinking style and attribution process. The present research extends this by measuring participants' thinking style within a single culture in order to ensure equivalence on potentially confounding variables such as prior knowledge and cognitive capacity. Two experiments demonstrate that both types of thinkers have identical attribution processes and suggest different thinking styles might relate to different tendencies toward situational information, but not to the attribution process itself. Copyright 2009 Elsevier B.V. All rights reserved.

  19. Measuring online interpretations and attributions of social situations: Links with adolescent social anxiety.

    Haller, Simone P W; Raeder, Sophie M; Scerif, Gaia; Cohen Kadosh, Kathrin; Lau, Jennifer Y F

    2016-03-01

    We evaluated the utility of a novel, picture-based tool to measure how adolescents interpret and attribute cause to social exchanges and whether biases in these processes relate to social anxiety. Briefly presented ambiguous visual social scenes, each containing a photograph of the adolescent as the protagonist, were followed by three possible interpretations (positive, negative, neutral/unrelated) and two possible causal attributions (internal, external) to which participants responded. Ninety-five adolescents aged 14 to 17 recruited from mainstream schools, with varying levels of social anxiety rated the likelihood of positive, negative and unrelated interpretations before selecting the single interpretation they deemed as most likely. This was followed by a question prompting them to decide between an internal or external causal attribution for the interpreted event. Across scenarios, adolescents with higher levels of social anxiety rated negative interpretations as more likely and positive interpretations as less likely compared to lower socially anxious adolescents. Higher socially anxious adolescents were also more likely to select internal attributions to negative and less likely to select internal attributions for positive events than adolescents with lower levels of social anxiety. Adolescents with higher social anxiety display cognitive biases in interpretation and attribution. This tool is suitable for measuring cognitive biases of complex visual-social cues in youth populations with social anxiety and simulates the demands of daily social experiences more closely. As we did not measure depressive symptoms, we cannot be sure that biases linked to social anxiety are not due to concurrent low mood. Copyright © 2015. Published by Elsevier Ltd.

  20. Assessing the Differences in Public Health Impact of Salmonella Subtypes Using a Bayesian Microbial Subtyping Approach for Source Attribution

    Pires, Sara Monteiro; Hald, Tine

    2010-01-01

    Salmonella is a major cause of human gastroenteritis worldwide. To prioritize interventions and assess the effectiveness of efforts to reduce illness, it is important to attribute salmonellosis to the responsible sources. Studies have suggested that some Salmonella subtypes have a higher health...... impact than others. Likewise, some food sources appear to have a higher impact than others. Knowledge of variability in the impact of subtypes and sources may provide valuable added information for research, risk management, and public health strategies. We developed a Bayesian model that attributes...... illness to specific sources and allows for a better estimation of the differences in the ability of Salmonella subtypes and food types to result in reported salmonellosis. The model accommodates data for multiple years and is based on the Danish Salmonella surveillance. The number of sporadic cases caused...

  1. Assessing the Applicability of Currently Available Methods for Attributing Foodborne Disease to Sources, Including Food and Food Commodities

    Pires, Sara Monteiro

    2013-01-01

    on the public health question being addressed, on the data requirements, on advantages and limitations of the method, and on the data availability of the country or region in question. Previous articles have described available methods for source attribution, but have focused only on foodborne microbiological...

  2. AVNG System Software-Attribute Verification System with Information Barriers for Mass Isotopic Measurements

    Elmont, T.H.; Langner, Diana C.; MacArthur, D.W.; Mayo, D.R.; Smith, M.K.; Modenov, A.

    2005-01-01

    This report describes the software development for the plutonium attribute verification system - AVNG. A brief synopsis of the technical solution for the measurement system is presented. The main tasks for the software development that is underway are formulated. The development tasks are shown in software structural flowcharts, measurement system state diagram and a description of the software. The current status of the AVNG software development is elucidated.

  3. Measuring radon source magnitude in residential buildings

    Nazaroff, W.W.; Boegel, M.L.; Nero, A.V.

    1981-08-01

    A description is given of procedures used in residences for rapid grab-sample and time-dependent measurements of the air-exchange rate and radon concentration. The radon source magnitude is calculated from the results of simultaneous measurements of these parameters. Grab-sample measurements in three survey groups comprising 101 US houses showed the radon source magnitude to vary approximately log-normally with a geometric mean of 0.37 and a range of 0.01 to 6.0 pCi 1 -1 h -1 . Successive measurements in six houses in the northeastern United States showed considerable variability in source magnitude within a given house. In two of these houses the source magnitude showed a strong correlation with the air-exchange rate, suggesting that soil gas influx can be an important transport process for indoor radon

  4. Particulate Matter and Ozone Prediction and Source Attribution for U.S. Air Quality Management in a Changing World

    Sanyal, S.; Wuebbles, D. J.

    2017-12-01

    In this study, the focus is on how global changes in climate and emissions will affect the U.S. air quality, especially on fine particulate matter and ozone, projecting their future trends and quantifying key source attribution. We are conducting three primary experiments : (1) historical simulations for period 1994-2013 to establish the credibility of the system and refine process-level understanding of U.S. regional air quality; (2) projections for period 2041-2060 to quantify individual and combined impacts of global climate and emissions changes under multiple scenarios; (3) sensitivity analyses to determine future changes in pollution sources and their relative contributions from anthropogenic and natural emissions, long-range pollutant transport, and climate change effects. Here we will present the result from the first experiment with the global model CESM1.2 (with fully coupled chemistry using CAM-chem5) driven by NASA Modern-Era Retrospective analysis for Research and Applications (MERRA) reanalysis data at 0.9o x 1.25o resolution. We will present the comparison between the results from model simulation with observation data from EPA database. Since there is always a challenge in comparing gridded prediction from model data with point data from the observation databases, because the model simulations calculate the average outcome over a grid for a given set of conditions while the stochastic component (e.g. sub-grid variations) embedded in the observations are not accounted for, we are using extensive statistical measure to do the comparison. We will also determine relative contributions from multiscale (local, regional, global) processes, major source regions (Mexico, Canada, Asia, Africa) and types (natural, anthropogenic) and associated uncertainties (climate decadal oscillations/interannual variations, emissions and model structure errors).

  5. Measurements of magnetic field sources in schools

    Johnson, G.B.

    1992-01-01

    The Electrical Systems Division of the Electric Power Research Institute (EPRI) has initiated several research projects to investigate magnetic field levels, their characteristics, and their sources. This paper describes measurements of magnetic field sources in schools. Magnetic field measurements were made at four schools in the service areas of two utility companies. Magnetic field measurements included profiles of the magnetic field versus distance near power lines, around the perimeter of the school buildings, and at several locations within each school. Twenty-four hour measurements were also made to record the temporal variation of the magnetic field at several locations at each school. The instrumentation, measurement techniques, and magnetic field sources identified are discussed

  6. Coupling meteorology, metal concentrations, and Pb isotopes for source attribution in archived precipitation samples.

    Graney, Joseph R; Landis, Matthew S

    2013-03-15

    A technique that couples lead (Pb) isotopes and multi-element concentrations with meteorological analysis was used to assess source contributions to precipitation samples at the Bondville, Illinois USA National Trends Network (NTN) site. Precipitation samples collected over a 16month period (July 1994-October 1995) at Bondville were parsed into six unique meteorological flow regimes using a minimum variance clustering technique on back trajectory endpoints. Pb isotope ratios and multi-element concentrations were measured using high resolution inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) on the archived precipitation samples. Bondville is located in central Illinois, ~250km downwind from smelters in southeast Missouri. The Mississippi Valley Type ore deposits in Missouri provided a unique multi-element and Pb isotope fingerprint for smelter emissions which could be contrasted to industrial emissions from the Chicago and Indianapolis urban areas (~125km north and east, of Bondville respectively) and regional emissions from electric utility facilities. Differences in Pb isotopes and element concentrations in precipitation corresponded to flow regime. Industrial sources from urban areas, and thorogenic Pb from coal use, could be differentiated from smelter emissions from Missouri by coupling Pb isotopes with variations in element ratios and relative mass factors. Using a three endmember mixing model based on Pb isotope ratio differences, industrial processes in urban airsheds contributed 56±19%, smelters in southeast Missouri 26±13%, and coal combustion 18±7%, of the Pb in precipitation collected in Bondville in the mid-1990s. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Is Causal Attribution of Sexual Deviance the Source of Thinking Errors?

    Paulauskas, Roland

    2013-01-01

    Adult and juvenile offenders exhibit a number of cognitive distortions related to sexually offending behaviors. The latter may be attributed to their developmental deficiencies, the result of operant conditioning, psychological self-defense mechanisms and biases, influence of negative environmental factors or criminal subculture. A group of…

  8. Progress of the AVNG System - Attribute Verification System with Information Barriers for Mass Isotopics Measurements

    Budnikov, D.; Bulatov, M.; Jarikhine, I.; Lebedev, B.; Livke, A.; Modenov, A.; Morkin, A.; Razinkov, S.; Tsaregorodtsev, D.; Vlokh, A.; Yakovleva, S.; Elmont, T.H.; Langner, D.C.; MacArthur, D.W.; Mayo, D.R.; Smith, M.K.; Luke, S.J.

    2005-01-01

    An attribute verification system (AVNG) with information barriers for mass and isotopics measurements has been designed and its fabrication is nearly completed. The AVNG is being built by scientists at the Russian Federal Nuclear Center-VNIIEF, with support of Los Alamos National Laboratory (LANL) and Lawrence Livermore National Laboratory (LLNL). Such a system could be used to verify the presence of several unclassified attributes of classified material with no classified information release. The system is comprised of a neutron multiplicity counter and gamma-spectrometry system based on a high purity germanium gamma detector (nominal relative efficiency @ 1332 keV 50%) and digital gamma-ray spectrometer DSPEC PLUS . The neutron multiplicity counter is a three ring counter with 164 3 He tubes. The system was designed to measure prototype containers 491 mm in diameter and 503 mm high. This paper provides a brief history of the project and documents the progress of this effort with drawings and photographs.

  9. High dose rate brachytherapy source measurement intercomparison.

    Poder, Joel; Smith, Ryan L; Shelton, Nikki; Whitaker, May; Butler, Duncan; Haworth, Annette

    2017-06-01

    This work presents a comparison of air kerma rate (AKR) measurements performed by multiple radiotherapy centres for a single HDR 192 Ir source. Two separate groups (consisting of 15 centres) performed AKR measurements at one of two host centres in Australia. Each group travelled to one of the host centres and measured the AKR of a single 192 Ir source using their own equipment and local protocols. Results were compared to the 192 Ir source calibration certificate provided by the manufacturer by means of a ratio of measured to certified AKR. The comparisons showed remarkably consistent results with the maximum deviation in measurement from the decay-corrected source certificate value being 1.1%. The maximum percentage difference between any two measurements was less than 2%. The comparisons demonstrated the consistency of well-chambers used for 192 Ir AKR measurements in Australia, despite the lack of a local calibration service, and served as a valuable focal point for the exchange of ideas and dosimetry methods.

  10. Seasonal Characteristics of Widespread Ozone Pollution in China and India: Current Model Capabilities and Source Attributions

    Gao, M.; Song, S.; Beig, G.; Zhang, H.; Hu, J.; Ying, Q.; McElroy, M. B.

    2017-12-01

    Fast urbanization and industrialization in China and India have led to severe ozone pollution, threatening public health in these densely populated countries. We show the spatial and seasonal characteristics of ozone concentrations using nation-wide observations for these two countries in 2013. We used the Weather Research and Forecasting model coupled to chemistry (WRF-Chem) to conduct one-year simulations and to evaluate how current models capture the important photochemical processes using the exhaustive available datasets in China and India, including surface measurements, ozonesonde data and satellite retrievals. We also employed the factor separation approach to distinguish the contributions of different sectors to ozone during different seasons. The back trajectory model FLEXPART was applied to investigate the role of transport in highly polluted regions (e.g., North China Plain, Yangtze River delta, and Pearl River Delta) during different seasons. Preliminary results indicate that the WRF-Chem model provides a satisfactory representation of the temporal and spatial variations of ozone for both China and India. The factor separation approach offers valuable insights into relevant sources of ozone for both countries providing valuable guidance for policy options designed to mitigate the related problem.

  11. Exploring the uncertainty in attributing sediment contributions in fingerprinting studies due to uncertainty in determining element concentrations in source areas.

    Gomez, Jose Alfonso; Owens, Phillip N.; Koiter, Alex J.; Lobb, David

    2016-04-01

    One of the major sources of uncertainty in attributing sediment sources in fingerprinting studies is the uncertainty in determining the concentrations of the elements used in the mixing model due to the variability of the concentrations of these elements in the source materials (e.g., Kraushaar et al., 2015). The uncertainty in determining the "true" concentration of a given element in each one of the source areas depends on several factors, among them the spatial variability of that element, the sampling procedure and sampling density. Researchers have limited control over these factors, and usually sampling density tends to be sparse, limited by time and the resources available. Monte Carlo analysis has been used regularly in fingerprinting studies to explore the probable solutions within the measured variability of the elements in the source areas, providing an appraisal of the probability of the different solutions (e.g., Collins et al., 2012). This problem can be considered analogous to the propagation of uncertainty in hydrologic models due to uncertainty in the determination of the values of the model parameters, and there are many examples of Monte Carlo analysis of this uncertainty (e.g., Freeze, 1980; Gómez et al., 2001). Some of these model analyses rely on the simulation of "virtual" situations that were calibrated from parameter values found in the literature, with the purpose of providing insight about the response of the model to different configurations of input parameters. This approach - evaluating the answer for a "virtual" problem whose solution could be known in advance - might be useful in evaluating the propagation of uncertainty in mixing models in sediment fingerprinting studies. In this communication, we present the preliminary results of an on-going study evaluating the effect of variability of element concentrations in source materials, sampling density, and the number of elements included in the mixing models. For this study a virtual

  12. Deaths Attributable to Diabetes in the United States: Comparison of Data Sources and Estimation Approaches.

    Stokes, Andrew; Preston, Samuel H

    2017-01-01

    The goal of this research was to identify the fraction of deaths attributable to diabetes in the United States. We estimated population attributable fractions (PAF) for cohorts aged 30-84 who were surveyed in the National Health Interview Survey (NHIS) between 1997 and 2009 (N = 282,322) and in the National Health and Nutrition Examination Survey (NHANES) between 1999 and 2010 (N = 21,814). Cohort members were followed prospectively for mortality through 2011. We identified diabetes status using self-reported diagnoses in both NHIS and NHANES and using HbA1c in NHANES. Hazard ratios associated with diabetes were estimated using Cox model adjusted for age, sex, race/ethnicity, educational attainment, and smoking status. We found a high degree of consistency between data sets and definitions of diabetes in the hazard ratios, estimates of diabetes prevalence, and estimates of the proportion of deaths attributable to diabetes. The proportion of deaths attributable to diabetes was estimated to be 11.5% using self-reports in NHIS, 11.7% using self-reports in NHANES, and 11.8% using HbA1c in NHANES. Among the sub-groups that we examined, the PAF was highest among obese persons at 19.4%. The proportion of deaths in which diabetes was assigned as the underlying cause of death (3.3-3.7%) severely understated the contribution of diabetes to mortality in the United States. Diabetes may represent a more prominent factor in American mortality than is commonly appreciated, reinforcing the need for robust population-level interventions aimed at diabetes prevention and care.

  13. Deaths Attributable to Diabetes in the United States: Comparison of Data Sources and Estimation Approaches.

    Andrew Stokes

    Full Text Available The goal of this research was to identify the fraction of deaths attributable to diabetes in the United States.We estimated population attributable fractions (PAF for cohorts aged 30-84 who were surveyed in the National Health Interview Survey (NHIS between 1997 and 2009 (N = 282,322 and in the National Health and Nutrition Examination Survey (NHANES between 1999 and 2010 (N = 21,814. Cohort members were followed prospectively for mortality through 2011. We identified diabetes status using self-reported diagnoses in both NHIS and NHANES and using HbA1c in NHANES. Hazard ratios associated with diabetes were estimated using Cox model adjusted for age, sex, race/ethnicity, educational attainment, and smoking status.We found a high degree of consistency between data sets and definitions of diabetes in the hazard ratios, estimates of diabetes prevalence, and estimates of the proportion of deaths attributable to diabetes. The proportion of deaths attributable to diabetes was estimated to be 11.5% using self-reports in NHIS, 11.7% using self-reports in NHANES, and 11.8% using HbA1c in NHANES. Among the sub-groups that we examined, the PAF was highest among obese persons at 19.4%. The proportion of deaths in which diabetes was assigned as the underlying cause of death (3.3-3.7% severely understated the contribution of diabetes to mortality in the United States.Diabetes may represent a more prominent factor in American mortality than is commonly appreciated, reinforcing the need for robust population-level interventions aimed at diabetes prevention and care.

  14. Atmospheric nitrogen deposition in the Yangtze River basin: Spatial pattern and source attribution

    Xu, Wen; Zhao, Yuanhong; Liu, Xuejun; Dore, Anthony J.; Zhang, Lin; Liu, Lei; Cheng, Miaomiao

    2018-01-01

    The Yangtze River basin is one of the world's hotspots for nitrogen (N) deposition and likely plays an important role in China's riverine N output. Here we constructed a basin-scale total dissolved inorganic N (DIN) deposition (bulk plus dry) pattern based on published data at 100 observational sites between 2000 and 2014, and assessed the relative contributions of different reactive N (N r ) emission sectors to total DIN deposition using the GEOS-Chem model. Our results show a significant spatial variation in total DIN deposition across the Yangtze River basin (33.2 kg N ha −1 yr −1 on average), with the highest fluxes occurring mainly in the central basin (e.g., Sichuan, Hubei and Hunan provinces, and Chongqing municipality). This indicates that controlling N deposition should build on mitigation strategies according to local conditions, namely, implementation of stricter control of N r emissions in N deposition hotspots but moderate control in the areas with low N deposition levels. Total DIN deposition in approximately 82% of the basin area exceeded the critical load of N deposition for semi-natural ecosystems along the basin. On the basin scale, the dominant source of DIN deposition is fertilizer use (40%) relative to livestock (11%), industry (13%), power plant (9%), transportation (9%), and others (18%, which is the sum of contributions from human waste, residential activities, soil, lighting and biomass burning), suggesting that reducing NH 3 emissions from improper fertilizer (including chemical and organic fertilizer) application should be a priority in curbing N deposition. This, together with distinct spatial variations in emission sector contributions to total DIN deposition also suggest that, in addition to fertilizer, major emission sectors in different regions of the basin should be considered when developing synergistic control measures. - Highlights: • Total DIN deposition fluxes showed a significant spatial variation in the

  15. The Effects of information barrier requirements on the trilateral initiative attribute measurement system (AVNG)

    MacArthur, D.W.; Langner, D.C.; Whiteson, R.; Wolford, J.K.

    2001-01-01

    Although the detection techniques used for measuring classified materials are very similar to those used in unclassified measurements, the surrounding packaging is generally very different. If iZ classified item is to be measured, an information barrier is required to protect any classified data acquired. This information barrier must protect the classified information while giving the inspector confidence that the unclassified outputs accurately reflect the classified inputs, Both information barrier and authentication considerations must be considered during all phases of system design and fabrication. One example of such a measurement system is the attribute measurement system (termed the AVNG) designed for the: Trilateral Initiative. We will discuss the integration of information barrier components into this system as well as the effects of an information barrier (including authentication) concerns on the implementation of the detector systems.

  16. High Speed Railway Environment Safety Evaluation Based on Measurement Attribute Recognition Model

    Qizhou Hu

    2014-01-01

    Full Text Available In order to rationally evaluate the high speed railway operation safety level, the environmental safety evaluation index system of high speed railway should be well established by means of analyzing the impact mechanism of severe weather such as raining, thundering, lightning, earthquake, winding, and snowing. In addition to that, the attribute recognition will be identified to determine the similarity between samples and their corresponding attribute classes on the multidimensional space, which is on the basis of the Mahalanobis distance measurement function in terms of Mahalanobis distance with the characteristics of noncorrelation and nondimensionless influence. On top of the assumption, the high speed railway of China environment safety situation will be well elaborated by the suggested methods. The results from the detailed analysis show that the evaluation is basically matched up with the actual situation and could lay a scientific foundation for the high speed railway operation safety.

  17. Accurate shear measurement with faint sources

    Zhang, Jun; Foucaud, Sebastien; Luo, Wentao

    2015-01-01

    For cosmic shear to become an accurate cosmological probe, systematic errors in the shear measurement method must be unambiguously identified and corrected for. Previous work of this series has demonstrated that cosmic shears can be measured accurately in Fourier space in the presence of background noise and finite pixel size, without assumptions on the morphologies of galaxy and PSF. The remaining major source of error is source Poisson noise, due to the finiteness of source photon number. This problem is particularly important for faint galaxies in space-based weak lensing measurements, and for ground-based images of short exposure times. In this work, we propose a simple and rigorous way of removing the shear bias from the source Poisson noise. Our noise treatment can be generalized for images made of multiple exposures through MultiDrizzle. This is demonstrated with the SDSS and COSMOS/ACS data. With a large ensemble of mock galaxy images of unrestricted morphologies, we show that our shear measurement method can achieve sub-percent level accuracy even for images of signal-to-noise ratio less than 5 in general, making it the most promising technique for cosmic shear measurement in the ongoing and upcoming large scale galaxy surveys

  18. Source Attributions and Persuasion: Perceived Honesty as a Determinant of Message Scrutiny.

    Priester, Joseph R.; Petty, Richard E.

    1995-01-01

    Examined hypothesis that cognitive misers (CM)--individuals low in the need for cognition--forego effortful message scrutiny with a presumably truthful communicator. Results showed that CMs depended more on message scrutiny when a knowledgeable source is of questionable honesty than when the source's honesty is clear. Other factors are discussed.…

  19. Radon measurements: the sources of uncertainties

    Zhukovsky, Michael; Onischenko, Alexandra; Bastrikov, Vladislav

    2008-01-01

    Full text: Radon measurements are quite complicated process and the correct estimation of uncertainties is very important. The sources of uncertainties for grab sampling, short term measurements (charcoal canisters), long term measurements (track detectors) and retrospective measurements (surface traps) are analyzed. The main sources of uncertainties for grab sampling measurements are: systematic bias of reference equipment; random Poisson and non-Poisson errors during calibration; random Poisson and non-Poisson errors during measurements. These sources are also common both for short term measurements (charcoal canisters) and long term measurements (track detectors). Usually during the calibration the high radon concentrations are used (1-5 kBq/m 3 ) and the Poisson random error rarely exceed some percents. Nevertheless the dispersion of measured values even during the calibration usually exceeds the Poisson dispersion expected on the basis of counting statistic. The origins of such non-Poisson random errors during calibration are different for different kinds of instrumental measurements. At present not all sources of non-Poisson random errors are trustworthy identified. The initial calibration accuracy of working devices rarely exceeds the value 20%. The real radon concentrations usually are in the range from some tens to some hundreds Becquerel per cubic meter and for low radon levels Poisson random error can reach up to 20%. The random non-Poisson errors and residual systematic biases are depends on the kind of measurement technique and the environmental conditions during radon measurements. For charcoal canisters there are additional sources of the measurement errors due to influence of air humidity and the variations of radon concentration during the canister exposure. The accuracy of long term measurements by track detectors will depend on the quality of chemical etching after exposure and the influence of season radon variations. The main sources of

  20. Risk Factors for Campylobacteriosis of Chicken, Ruminant, and Environmental Origin: A Combined Case-Control and Source Attribution Analysis

    Wagenaar, Jaap A.; de Boer, Albert G.; Havelaar, Arie H.; Friesema, Ingrid H. M.; French, Nigel P.; Busani, Luca; van Pelt, Wilfrid

    2012-01-01

    campylobacteriosis are investigated in relation to the attributed reservoirs based on MLST profiles. Combining epidemiological and source attribution data improved campylobacteriosis risk factor identification and characterization, generated hypotheses, and showed that genotype-based source attribution is epidemiologically sensible. PMID:22880049

  1. Risk factors for campylobacteriosis of chicken, ruminant, and environmental origin: a combined case-control and source attribution analysis.

    Lapo Mughini Gras

    factors for campylobacteriosis are investigated in relation to the attributed reservoirs based on MLST profiles. Combining epidemiological and source attribution data improved campylobacteriosis risk factor identification and characterization, generated hypotheses, and showed that genotype-based source attribution is epidemiologically sensible.

  2. Atmospheric nitrogen deposition in the Yangtze River basin: Spatial pattern and source attribution.

    Xu, Wen; Zhao, Yuanhong; Liu, Xuejun; Dore, Anthony J; Zhang, Lin; Liu, Lei; Cheng, Miaomiao

    2018-01-01

    The Yangtze River basin is one of the world's hotspots for nitrogen (N) deposition and likely plays an important role in China's riverine N output. Here we constructed a basin-scale total dissolved inorganic N (DIN) deposition (bulk plus dry) pattern based on published data at 100 observational sites between 2000 and 2014, and assessed the relative contributions of different reactive N (N r ) emission sectors to total DIN deposition using the GEOS-Chem model. Our results show a significant spatial variation in total DIN deposition across the Yangtze River basin (33.2 kg N ha -1 yr -1 on average), with the highest fluxes occurring mainly in the central basin (e.g., Sichuan, Hubei and Hunan provinces, and Chongqing municipality). This indicates that controlling N deposition should build on mitigation strategies according to local conditions, namely, implementation of stricter control of N r emissions in N deposition hotspots but moderate control in the areas with low N deposition levels. Total DIN deposition in approximately 82% of the basin area exceeded the critical load of N deposition for semi-natural ecosystems along the basin. On the basin scale, the dominant source of DIN deposition is fertilizer use (40%) relative to livestock (11%), industry (13%), power plant (9%), transportation (9%), and others (18%, which is the sum of contributions from human waste, residential activities, soil, lighting and biomass burning), suggesting that reducing NH 3 emissions from improper fertilizer (including chemical and organic fertilizer) application should be a priority in curbing N deposition. This, together with distinct spatial variations in emission sector contributions to total DIN deposition also suggest that, in addition to fertilizer, major emission sectors in different regions of the basin should be considered when developing synergistic control measures. Copyright © 2017. Published by Elsevier Ltd.

  3. Calorimetric measurement of strong γ emitting sources

    Brangier, B.; Herczeg, C.; Henry, R.

    1968-01-01

    This publication gives the principle and a description of an adiabatic calorimeter for measuring the real activity of strong gamma-emitting sources by absorbing the emitted energy in a mass of copper. Because of the difficulty of evaluating the amount self- absorption, we have built a calorimeter for measuring the self- absorption, and a description of it is given.The results of these three measurements are fairly satisfactory. The calibration and the actual measurements obtained are given with a few corrections made necessary by the design of the apparatus. The correlation of the various results is discussed. (author) [fr

  4. Beam emittance measurements on multicusp ion sources

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  5. Beam emittance measurements on multicusp ion sources

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  6. Attribute measurement equipment for the verification of plutonium in classified forms for the Trilateral Initiative

    Langner, D.G.; Hsue, S.-T.; Macarthur, D.W.

    2001-01-01

    Full text: A team of technical experts from the Russian Federation, the International Atomic Energy Agency (IAEA) and the United States have been working for almost five years on the development of a tool kit of instruments that could be used to verify plutonium-bearing items that have classified characteristics in nuclear weapons states. This suite of instruments is similar in many ways to standard safeguards equipment and includes high-resolution gamma-ray spectrometers, neutron multiplicity counters, gross neutron counters and gross gamma-ray detectors. In safeguards applications, this equipment is known to be robust, and authentication methods are well understood. This equipment is very intrusive, however, and a traditional safeguards application of such equipment for verification of materials with classified characteristics would reveal classified information to the inspector, Several enabling technologies have been or are being developed to facilitate the use of these trusted, but intrusive technologies. In this paper, these technologies will be described. One of the new technologies is called an Attribute Verification System with an Information Barrier Utilizing Neutron Multiplicity Counting and High-Resolution Gamma-Ray Spectrometry' or AVNG. The radiation measurement equipment, comprising a neutron multiplicity counter and high-resolution gamma-ray spectrometer, is standard safeguards-type equipment with information security features added. The information barrier is a combination of technical and procedural methods that protect classified information while allowing the inspector to have confidence that the measurement equipment is providing authentic results. The approach is to reduce the radiation data collected by the measurement equipment to a simple 'yes/no' result regarding attributes of the plutonium-bearing item. The 'yes/no' result is unclassified by design so that it can be shared with an inspector. The attributes that the Trilateral Initiative

  7. Attributing Methane and Carbon Dioxide Emissions from Anthropogenic and Natural Sources Using AVIRIS-NG

    Thorpe, A. K.; Frankenberg, C.; Thompson, D. R.; Duren, R. M.; Aubrey, A. D.; Bue, B. D.; Green, R. O.; Gerilowski, K.; Krings, T.; Borchardt, J.; Kort, E. A.; Sweeney, C.; Conley, S. A.; Roberts, D. A.; Dennison, P. E.; Ayasse, A.

    2016-12-01

    Imaging spectrometers like the next generation Airborne Visible/Infrared Imaging Spectrometer (AVIRIS-NG) can map large regions with the high spatial resolution necessary to resolve methane (CH4) and carbon dioxide (CO2) emissions. This capability is aided by real time detection and geolocation of gas plumes, permitting unambiguous identification of individual emission source locations and communication to ground teams for rapid follow up. We present results from AVIRIS-NG flight campaigns in the Four Corners region (Colorado and New Mexico) and the San Joaquin Valley (California). Over three hundred plumes were observed, reflecting emissions from anthropogenic and natural sources. Examples of plumes will be shown for a number of sources, including CH4 from well completions, gas processing plants, tanks, pipeline leaks, natural seeps, and CO2 from power plants. Despite these promising results, an imaging spectrometer built exclusively for quantitative mapping of gas plumes would have improved sensitivity compared to AVIRIS-NG. For example, an instrument providing a 1 nm spectral sampling (2,000-2,400 micron) would permit mapping CH4, CO2, H2O, CO, and N2O from more diffuse sources using both airborne and orbital platforms. The ability to identify emission sources offers the potential to constrain regional greenhouse gas budgets and improve partitioning between anthropogenic and natural emission sources. Because the CH4 lifetime is only about 9 years and CH4 has a Global Warming Potential 86 times that of CO2 for a 20 year time interval, mitigating these emissions is a particularly cost-effective approach to reduce overall atmospheric radiative forcing. Fig. 1. True color image subset with superimposed gas plumes showing concentrations in ppmm. Left: AVIRIS-NG observed CH4 plumes from natural gas processing plant extending over 500 m downwind of multiple emissions sources. Right: Multiple CO2 plumes observed from coal-fired power plant.

  8. The Effect of Irrigation and Nitrogen on Growth Attributes and Chlorophyll Content of Garlic in Line Source Sprinkler Irrigation System

    rahim motalebifard

    2017-02-01

    Full Text Available Introduction: With 12 million tons production per year, garlic is the fourth important crop in world. In addition to its medical value, it has been used in food industry. The Hamedan province with 1900 ha cultivation area and 38 percent of production is one of the most important garlic area productions in Iran. Few studies on water use and management of garlic exist in the world. Garlic is very sensitive to water deficit especially in tubers initiation and ripening periods. The current research was done because of scarce research on garlic production under water deficit condition in Iran and importance of plant nutrition and nutrients especially nitrogen on garlic production under stressful conditions. Nitrogen is necessary and important element for increasing the yield and quality of garlic. Application of nitrogen increases the growth trend of garlic such as number of leaves, leaf length and plant body. Reports have shown that garlic has high nitrogen requirement, particularly in the early stages of growth. Materials and Methods: This study was conducted for evaluating the combined effects of nitrogen and irrigation on the yield and quality of garlic (Allium sativumL.. The study was performed as a split-block based on randomized complete blocks design with factors of irrigation at four levels (0-3(normal irrigation, 3-6 (slight water deficit, 6-9 (moderate water deficit and 9-12 (sever water deficit meters distance from main line source sprinkler system, nitrogen at four levels (0, 50,100 and 150 kg nitrogen per ha using three replications and line source sprinkler irrigation system. The total water of irrigation levels was measured by boxes that were fixed in meddle of each plot. The statistical analysis of results were performed using themethod described by Hanks (1980. The chlorophyll index was measured using the chlorophyll meter 502 (Minolta, Spain. The chlorophyll a and bwas measured by the method described by Arnon (1946 and Gross (1991

  9. Psychological restoration can depend on stimulus-source attribution: A challenge for the evolutionary account?

    Andreas Haga

    2016-11-01

    Full Text Available Visiting or viewing nature environments can have restorative psychological effects, while exposure to the built environment typically has less positive effects. A classic view is that this difference in restorative potential of nature and built environments depends on differences in the intrinsic characteristics of the stimuli. In addition, an evolutionary account is often assumed whereby restoration is believed to be a hardwired response to nature’s stimulus-features. Here, we propose the novel hypothesis that the restorative effects of a stimulus do not entirely depend on the stimulus-features per se, but also on the meaning that people assign to the stimulus. Participants conducted cognitively demanding tests prior to and after a brief pause. During the pause, the participants were exposed to an ambiguous sound consisting of pink noise with white noise interspersed. Participants in the nature sound-source condition were told that the sound originated from a nature scene with a waterfall; participants in the industrial sound-source condition were told that the sound originated from an industrial environment with machinery; and participants in the control condition were told nothing about the sound origin. Self-reported mental exhaustion showed that participants in the nature sound-source condition were more psychologically restored after the pause than participants in the industrial sound-source condition. One potential interpretation of the results is that restoration from nature experiences depends on learned, positive associations with nature; not only on hardwired responses shaped by evolution.

  10. Attributing the human disease burden of foodborne infections to specific sources.

    Pires, S.M.; Evers, E.G.; van Pelt, W.; Ayers, T.; Scallan, E.; Angulo, F.J.; Havelaar, A.H.; Hald, T.

    2009-01-01

    Foodborne diseases are an important cause of human illness worldwide. Humans acquire these infections from a variety of sources and routes of transmission. Many efforts have been made in the last decades to prevent and control foodborne diseases, particularly foodborne zoonoses. However, information

  11. Premature Deaths Attributed to Source-Specific BC Emissions in Six Urban US Regions

    Turner, M.D.; Henze, D.K.; Capps, S.; Hakami, A.; Zhao, S.; Resler, Jaroslav; Carmichael, G.; Stanier, C.; Baek, J.; Sandu, A.; Russell, A.G.; Nenes, A.; Pinder, R.; Napelenok, S.; Bash, J.; Percell, P.; Chai, T.

    2015-01-01

    Roč. 10, č. 11 (2015), Article 114014 ISSN 1748-9326 Grant - others:NASA Applied Sciences Program(US) NNX09AN77G Institutional support: RVO:67985807 Keywords : air quality * health impact * source apportionment * adjoint * particulate matter * black car bon Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 4.134, year: 2015

  12. Attributing the Human Disease Burden of Foodborne Infections to Specific Sources

    Pires, Sara Monteiro; Evers, Eric E.; Van Pely, Wilfrid

    2009-01-01

    Foodborne diseases are an important cause of human illness worldwide. Humans acquire these infections from a variety of sources and routes of transmission. Many efforts have been made in the last decades to prevent and control foodborne diseases, particularly foodborne zoonoses. However...

  13. Premature Deaths Attributed to Source-Specific BC Emissions in Six Urban US Regions

    Turner, M.D.; Henze, D.K.; Capps, S.; Hakami, A.; Zhao, S.; Resler, Jaroslav; Carmichael, G.; Stanier, C.; Baek, J.; Sandu, A.; Russell, A.G.; Nenes, A.; Pinder, R.; Napelenok, S.; Bash, J.; Percell, P.; Chai, T.

    2015-01-01

    Roč. 10, č. 11 (2015), Article 114014 ISSN 1748-9326 Grant - others: NASA Applied Sciences Program(US) NNX09AN77G Institutional support: RVO:67985807 Keywords : air quality * health impact * source apportionment * adjoint * particulate matter * black carbon Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 4.134, year: 2015

  14. Spatiotemporal patterns and source attribution of nitrogen pollution in a typical headwater agricultural watershed in Southeastern China.

    Chen, Wenjun; He, Bin; Nover, Daniel; Duan, Weili; Luo, Chuan; Zhao, Kaiyan; Chen, Wen

    2018-01-01

    Excessive nitrogen (N) discharge from agriculture causes widespread problems in aquatic ecosystems. Knowledge of spatiotemporal patterns and source attribution of N pollution is critical for nutrient management programs but is poorly studied in headwaters with various small water bodies and mini-point pollution sources. Taking a typical small watershed in the low mountains of Southeastern China as an example, N pollution and source attribution were studied for a multipond system around a village using the Hydrological Simulation Program-Fortran (HSPF) model. The results exhibited distinctive spatio-seasonal variations with an overall seriousness rank for the three indicators: total nitrogen (TN) > nitrate/nitrite nitrogen (NO x - -N) > ammonia nitrogen (NH 3 -N), according to the Chinese Surface Water Quality Standard. TN pollution was severe for the entire watershed, while NO x - -N pollution was significant for ponds and ditches far from the village, and the NH 3 -N concentrations were acceptable except for the ponds near the village in summer. Although food and cash crop production accounted for the largest source of N loads, we discovered that mini-point pollution sources, including animal feeding operations, rural residential sewage, and waste, together contributed as high as 47% of the TN and NH 3 -N loads in ponds and ditches. So, apart from eco-fertilizer programs and concentrated animal feeding operations, the importance of environmental awareness building for resource management is highlighted for small farmers in headwater agricultural watersheds. As a first attempt to incorporate multipond systems into the process-based modeling of nonpoint source (NPS) pollution, this work can inform other hydro-environmental studies on scattered and small water bodies. The results are also useful to water quality improvement for entire river basins.

  15. Using temporal sampling to improve attribution of source populations for invasive species.

    Sharyn J Goldstien

    Full Text Available Numerous studies have applied genetic tools to the identification of source populations and transport pathways for invasive species. However, there are many gaps in the knowledge obtained from such studies because comprehensive and meaningful spatial sampling to meet these goals is difficult to achieve. Sampling populations as they arrive at the border should fill the gaps in source population identification, but such an advance has not yet been achieved with genetic data. Here we use previously acquired genetic data to assign new incursions as they invade populations within New Zealand ports and marinas. We also investigated allelelic frequency change in these recently established populations over a two-year period, and assessed the effect of temporal genetic sampling on our ability to assign new incursions to their population of source. We observed shifts in the allele frequencies among populations, as well as the complete loss of some alleles and the addition of alleles novel to New Zealand, within these recently established populations. There was no significant level of genetic differentiation observed in our samples between years, and the use of these temporal data did alter the assignment probability of new incursions. Our study further suggests that new incursions can add genetic variation to the population in a single introduction event as the founders themselves are often more genetically diverse than theory initially predicted.

  16. Multi-attribute integrated measurement of node importance in complex networks.

    Wang, Shibo; Zhao, Jinlou

    2015-11-01

    The measure of node importance in complex networks is very important to the research of networks stability and robustness; it also can ensure the security of the whole network. Most researchers have used a single indicator to measure the networks node importance, so that the obtained measurement results only reflect certain aspects of the networks with a loss of information. Meanwhile, because of the difference of networks topology, the nodes' importance should be described by combining the character of the networks topology. Most of the existing evaluation algorithms cannot completely reflect the circumstances of complex networks, so this paper takes into account the degree of centrality, the relative closeness centrality, clustering coefficient, and topology potential and raises an integrated measuring method to measure the nodes' importance. This method can reflect nodes' internal and outside attributes and eliminate the influence of network structure on the node importance. The experiments of karate network and dolphin network show that networks topology structure integrated measure has smaller range of metrical result than a single indicator and more universal. Experiments show that attacking the North American power grid and the Internet network with the method has a faster convergence speed than other methods.

  17. A generalized measurement model to quantify health: the multi-attribute preference response model.

    Krabbe, Paul F M

    2013-01-01

    After 40 years of deriving metric values for health status or health-related quality of life, the effective quantification of subjective health outcomes is still a challenge. Here, two of the best measurement tools, the discrete choice and the Rasch model, are combined to create a new model for deriving health values. First, existing techniques to value health states are briefly discussed followed by a reflection on the recent revival of interest in patients' experience with regard to their possible role in health measurement. Subsequently, three basic principles for valid health measurement are reviewed, namely unidimensionality, interval level, and invariance. In the main section, the basic operation of measurement is then discussed in the framework of probabilistic discrete choice analysis (random utility model) and the psychometric Rasch model. It is then shown how combining the main features of these two models yields an integrated measurement model, called the multi-attribute preference response (MAPR) model, which is introduced here. This new model transforms subjective individual rank data into a metric scale using responses from patients who have experienced certain health states. Its measurement mechanism largely prevents biases such as adaptation and coping. Several extensions of the MAPR model are presented. The MAPR model can be applied to a wide range of research problems. If extended with the self-selection of relevant health domains for the individual patient, this model will be more valid than existing valuation techniques.

  18. Assessing the empirical validity of alternative multi-attribute utility measures in the maternity context

    Morrell Jane

    2009-05-01

    Full Text Available Abstract Background Multi-attribute utility measures are preference-based health-related quality of life measures that have been developed to inform economic evaluations of health care interventions. The objective of this study was to compare the empirical validity of two multi-attribute utility measures (EQ-5D and SF-6D based on hypothetical preferences in a large maternity population in England. Methods Women who participated in a randomised controlled trial of additional postnatal support provided by trained community support workers represented the study population for this investigation. The women were asked to complete the EQ-5D descriptive system (which defines health-related quality of life in terms of five dimensions: mobility, self care, usual activities, pain/discomfort and anxiety/depression and the SF-36 (which defines health-related quality of life, using 36 items, across eight dimensions: physical functioning, role limitations (physical, social functioning, bodily pain, general health, mental health, vitality and role limitations (emotional at six months postpartum. Their responses were converted into utility scores using the York A1 tariff set and the SF-6D utility algorithm, respectively. One-way analysis of variance was used to test the hypothetically-constructed preference rule that each set of utility scores differs significantly by self-reported health status (categorised as excellent, very good, good, fair or poor. The degree to which EQ-5D and SF-6D utility scores reflected alternative dichotomous configurations of self-reported health status and the Edinburgh Postnatal Depression Scale score was tested using the relative efficiency statistic and receiver operating characteristic (ROC curves. Results The mean utility score for the EQ-5D was 0.861 (95% CI: 0.844, 0.877, whilst the mean utility score for the SF-6D was 0.809 (95% CI: 0.796, 0.822, representing a mean difference in utility score of 0.052 (95% CI: 0.040, 0

  19. Measuring Modularity in Open Source Code Bases

    Roberto Milev

    2009-03-01

    Full Text Available Modularity of an open source software code base has been associated with growth of the software development community, the incentives for voluntary code contribution, and a reduction in the number of users who take code without contributing back to the community. As a theoretical construct, modularity links OSS to other domains of research, including organization theory, the economics of industry structure, and new product development. However, measuring the modularity of an OSS design has proven difficult, especially for large and complex systems. In this article, we describe some preliminary results of recent research at Carleton University that examines the evolving modularity of large-scale software systems. We describe a measurement method and a new modularity metric for comparing code bases of different size, introduce an open source toolkit that implements this method and metric, and provide an analysis of the evolution of the Apache Tomcat application server as an illustrative example of the insights gained from this approach. Although these results are preliminary, they open the door to further cross-discipline research that quantitatively links the concerns of business managers, entrepreneurs, policy-makers, and open source software developers.

  20. Elemental source attribution signatures for calcium ammonium nitrate (CAN) fertilizers used in homemade explosives

    Fraga, Carlos G.; Mitroshkov, Alexander V.; Mirjankar, Nikhil S.; Dockendorff, Brian P.; Melville, Angie M.

    2017-11-01

    Calcium ammonium nitrate (CAN) is a widely available fertilizer composed of ammonium nitrate mixed with some form of calcium carbonate such as limestone or dolomite. CAN is also frequently used to make homemade explosives. The potential of using elemental profiling and chemometrics to match both pristine and reprocessed CAN fertilizers to their factories for use in future forensic investigations was examined. Inductively coupled plasma-mass spectrometry (ICP-MS) analysis was performed on 64 elements in 125 samples from 11 CAN stocks from 6 different CAN factories. Fisher ratio, degree-of-class-separation, and partial least squares discriminant analysis (PLSDA) were used to develop a model using the concentrations of Na, V, Mn, Cu, Ga, Sr, Ba and U to classify a validation set of CAN samples into 5 factory groups; one group was two factories from the same fertilizer company. In terms of the pristine CAN samples, i.e., unadulterated prills, 64% of the test samples were matched to their correct factory group with zero false positives. The same PLSDA model was used to correctly match 100% of the CAN samples that were reprocessed by crushing and mixing the CAN with powdered sugar. In the case of crushed CAN samples mixed with aluminum powder, correct matches were made for zero to 100% of the samples depending on the factory the CAN originated. Remarkably, for one factory, 100% of the ammonium nitrate samples that were extracted from CAN using tap or bottled water were matched to the correct CAN factory group. Lastly, the water-insoluble (calcium carbonate) portions of CAN provided a greater degree of discrimination between factories than the water-soluble portions of CAN. In summary, this work illustrates that sourcing unadulterated CAN fertilizer can potentially be done with high frequency and high confidence using elemental profiling and chemometrics while the sourcing of reprocessed CAN is dependent on how much an adulterant alters the recovered elemental profile of

  1. Portable gamma-ray holdup and attributes measurements of high- and variable-burnup plutonium

    Wenz, T.R.; Russo, P.A.; Miller, M.C.; Menlove, H.O.; Takahashi, S.; Yamamoto, Y.; Aoki, I.

    1991-01-01

    High burnup-plutonium holdup has been assayed quantitatively by low resolution gamma-ray spectrometry. The assay was calibrated with four plutonium standards representing a range of fuel burnup and 241 Am content. Selection of a calibration standard based on its qualitative spectral similarity to gamma-ray spectra of the process material is partially responsible for the success of these holdup measurements. The spectral analysis method is based on the determination of net counts in a single spectral region of interest (ROI). However, the low-resolution gamma-ray assay signal for the high-burnup plutonium includes unknown amounts of contamination from 241 Am. For most needs, the range of calibration standards required for this selection procedure is not available. A new low-resolution gamma-ray spectral analysis procedure for assay of 239 Pu has been developed. The procedure uses the calculated isotope activity ratios and the measured net counts in three spectral ROIs to evaluate and remove the 241 Am contamination from the 239 Pu assay signal on a spectrum-by-spectrum basis. The calibration for the new procedure requires only a single plutonium standard. The procedure also provides a measure of the burnup and age attributes of holdup deposits. The new procedure has been demonstrated using portable gamma-ray spectroscopy equipment for a wide range of plutonium standards and has also been applied to the assay of 239 Pu holdup in a mixed oxide fuel fabrication facility. 10 refs., 5 figs., 3 tabs

  2. Near-ground ozone source attributions and outflow in central eastern China during MTX2006

    Li, J.; Wang, Z.; Akimoto, H.; Yamaji, K.; Takigawa, M.; Pochanart, P.; Liu, Y.; Tanimoto, H.; Kanaya, Y.

    2008-12-01

    A 3-D regional chemical transport model, the Nested Air Quality Prediction Model System (NAQPMS), with an on-line tracer tagging module was used to study the source of the near-ground (pollutants, and it captured highly polluted and clean cases well. The simulated near-ground ozone level over CEC was 60-85 ppbv (parts per billion by volume), which was higher than values in Japan and over the North Pacific (20-50 ppbv). The simulated tagged tracer data indicated that the regional-scale transport of chemically produced ozone over other areas in CEC contributed to the greatest fraction (49%) of the near-ground mean ozone at Mt. Tai in June; in situ photochemistry contributed only 12%. Due to high anthropogenic and biomass burning emissions that occurred in the southern part of the CEC, the contribution to ground ozone levels from this area played the most important role (32.4 ppbv, 37.9% of total ozone) in the monthly mean ozone concentration at Mt. Tai; values reached 59 ppbv (62%) on 6-7 June 2006. The monthly mean horizontal distribution of chemically produced ozone from various ozone production regions indicated that photochemical reactions controlled the spatial distribution of O3 over CEC. The regional-scale transport of pollutants also played an important role in the spatial and temporal distribution of ozone over CEC. Chemically produced ozone from the southern part of the study region can be transported northeastwardly to the northern rim of CEC; the mean contribution was 5-10 ppbv, and it reached 25 ppbv during high ozone events. Studies of the outflow of CEC ozone and its precursors, as well as their influences and contributions to the ozone level over adjacent regions/countries, revealed that the contribution of CEC ozone to mean ozone mixing ratios over the Korean Peninsula and Japan was 5-15 ppbv, of which about half was due to the direct transport of ozone from CEC and half was produced locally by ozone precursors transported from CEC.

  3. A Python-Based Open Source System for Geographic Object-Based Image Analysis (GEOBIA Utilizing Raster Attribute Tables

    Daniel Clewley

    2014-06-01

    Full Text Available A modular system for performing Geographic Object-Based Image Analysis (GEOBIA, using entirely open source (General Public License compatible software, is presented based around representing objects as raster clumps and storing attributes as a raster attribute table (RAT. The system utilizes a number of libraries, developed by the authors: The Remote Sensing and GIS Library (RSGISLib, the Raster I/O Simplification (RIOS Python Library, the KEA image format and TuiView image viewer. All libraries are accessed through Python, providing a common interface on which to build processing chains. Three examples are presented, to demonstrate the capabilities of the system: (1 classification of mangrove extent and change in French Guiana; (2 a generic scheme for the classification of the UN-FAO land cover classification system (LCCS and their subsequent translation to habitat categories; and (3 a national-scale segmentation for Australia. The system presented provides similar functionality to existing GEOBIA packages, but is more flexible, due to its modular environment, capable of handling complex classification processes and applying them to larger datasets.

  4. Sources and protective measures of indoor radon

    Gou Quanlu; Wang Hengde

    1993-01-01

    This paper presents the relative contribution to indoor radon 222 Rn of various sources in twenty three rooms of three kinds in Taiyuan area. The results show that the major sources in this area are radon emanation from surfaces of soil and building materials and that from outdoor air, while the contribution of water and gas consumed in the rooms is less important. These results suggest a basis for taking suitable protective measures against indoor radon. Some materials are also recommended which are effective in restraining radon exhalation and low in price, by testing more than ten kinds of materials and comparing them using cost-effectiveness analysis technique, such as painting materials, polyvinyl alcohol (CH 2 :CHOH)n, etc. Their sealing effects on radon exhalation were examined with home-made REM-89 Radon Exhalation Monitor. The deposition effects of negative ion generator and humidifier on radon progeny were also tested. The maximum deposition may reach 70-90%, which proves they are also effective and economical in radon protection. (2 tabs., 3 figs.)

  5. Multi-Attribute Decision Making Based on Several Trigonometric Hamming Similarity Measures under Interval Rough Neutrosophic Environment

    Surapati Pramanik

    2018-03-01

    Full Text Available In this paper, the sine, cosine and cotangent similarity measures of interval rough neutrosophic sets is proposed. Some properties of the proposed measures are discussed. We have proposed multi attribute decision making approaches based on proposed similarity measures. To demonstrate the applicability, a numerical example is solved.

  6. Aircrew radiation exposure: sources-risks-measurement

    Duftschmid, K.E.

    1994-05-01

    A short review is given on the actual aircrew exposure and its sources. The resulting risks for harmful effects to the health and discuss methods for in-flight measurements of exposure is evaluated. An idea for a fairly simple and economic approach to a practical, airborne active dosimeter for the assessment of individual crew exposure is presented. The exposure of civil aircrew to cosmic radiation, should not be considered a tremendous risk to the health, there is no reason for panic. However, being significantly higher than the average exposure to radiation workers, it can certainly not be neglected. As recommended by ICRP, aircrew exposure has to be considered occupational radiation exposure and aircrews are certainly entitled to the same degree of protection, as other ground-based radiation workers have obtained by law, since long time. (author)

  7. Developing a Questionnaire to Measure Perceived Attributes of eHealth Innovations

    Atkinson, Nancy L.

    2007-01-01

    Objectives: To design a valid and reliable questionnaire to assess perceived attributes of technology-based health education innovations. Methods: College students in 12 personal health courses reviewed a prototype eHealth intervention using a 30-item instrument based upon diffusion theory's perceived attributes of an innovation. Results:…

  8. Positivity effect in source attributions of arousal-matched emotional and non-emotional words during item-based directed forgetting.

    Gallant, Sara N; Yang, Lixia

    2014-01-01

    Consistent with their emphasis on emotional goals, older adults often exhibit a positivity bias in attention and memory relative to their young counterparts (i.e., a positivity effect). The current study sought to determine how this age-related positivity effect would impact intentional forgetting of emotional words, a process critical to efficient operation of memory. Using an item-based directed forgetting task, 36 young and 36 older adults studied a series of arousal-equivalent words that varied in valence (i.e., positive, negative, and neutral). Each word was followed by a cue to either remember or forget the word. A subsequent "tagging" recognition task required classification of items as to-be-remembered (TBR), to-be-forgotten (TBF), or new as a measure of directed forgetting and source attribution in participants' memory. Neither young nor older adults' intentional forgetting was affected by the valence of words. A goal-consistent valence effect did, however, emerge in older adults' source attribution performance. Specifically, older adults assigned more TBR-cues to positive words and more TBF-cues to negative words. Results are discussed in light of existing literature on emotion and directed forgetting as well as the socioemotional selectivity theory underlying the age-related positivity effect.

  9. Positivity effect in source attributions of arousal-matched emotional and non-emotional words during item-based directed forgetting

    Sara N. Gallant

    2014-11-01

    Full Text Available Consistent with their emphasis on emotional goals, older adults often exhibit a positivity bias in attention and memory relative to their young counterparts (i.e., a positivity effect. The current study sought to determine how this age-related positivity effect would impact intentional forgetting of emotional words, a process critical to efficient operation of memory. Using an item-based directed forgetting task, 36 young and 36 older adults studied a series of arousal-equivalent words that varied in valence (i.e., positive, negative, and neutral. Each word was followed by a cue to either remember or forget the word. A subsequent tagging recognition task required classification of items as to-be-remembered (TBR, to-be-forgotten (TBF, or new as a measure of directed forgetting and source attribution in participants’ memory. Valence did not affect intentional forgetting in both young and older age groups. A goal-consistent valence effect did, however, emerge in older adults’ source attribution performance. Specifically, older adults assigned more TBR-cues to positive words and more TBF-cues to negative words. Results are discussed in light of existing literature on emotion and directed forgetting as well as the socioemotional selectivity theory underlying the age-related positivity effect.

  10. How do different humanness measures relate? Confronting the attribution of secondary emotions, human uniqueness, and human nature traits.

    Martínez, Rocío; Rodriguez-Bailon, Rosa; Moya, Miguel; Vaes, Jeroen

    2017-01-01

    The present research examines the relationship between the infrahumanization approach and the two-dimensional model of humanness: an issue that has received very little empirical attention. In Study 1, we created three unknown groups (Humanized, Animalized, and Mechanized) granting/denying them Human Nature (HN) and Human Uniqueness (HU) traits. The attribution of primary/secondary emotions was measured. As expected, participants attributed more secondary emotions to the humanized compared to dehumanized groups. Importantly, both animalized and mechanized groups were attributed similar amounts of secondary emotions. In Study 2, the groups were described in terms of their capacity to express secondary emotions. We measured the attribution of HN/HU traits. Results showed that the infrahumanized group was denied both HU/HN traits. The results highlight the importance of considering the common aspects of both approaches in understanding processes of dehumanization.

  11. Application of Molecular Typing Results in Source Attribution Models: The Case of Multiple Locus Variable Number Tandem Repeat Analysis (MLVA) of Salmonella Isolates Obtained from Integrated Surveillance in Denmark

    de Knegt, Leonardo; Pires, Sara Monteiro; Löfström, Charlotta

    2016-01-01

    , and antibiotic resistance profiles for the Salmonella source attribution, and assess the utility of the results for the food safety decisionmakers. Full and simplified MLVA schemes from surveillance data were tested, and model fit and consistency of results were assessed using statistical measures. We conclude...

  12. Attributed graph distance measure for automatic detection of attention deficit hyperactive disordered subjects.

    Dey, Soumyabrata; Rao, A Ravishankar; Shah, Mubarak

    2014-01-01

    Attention Deficit Hyperactive Disorder (ADHD) is getting a lot of attention recently for two reasons. First, it is one of the most commonly found childhood disorders and second, the root cause of the problem is still unknown. Functional Magnetic Resonance Imaging (fMRI) data has become a popular tool for the analysis of ADHD, which is the focus of our current research. In this paper we propose a novel framework for the automatic classification of the ADHD subjects using their resting state fMRI (rs-fMRI) data of the brain. We construct brain functional connectivity networks for all the subjects. The nodes of the network are constructed with clusters of highly active voxels and edges between any pair of nodes represent the correlations between their average fMRI time series. The activity level of the voxels are measured based on the average power of their corresponding fMRI time-series. For each node of the networks, a local descriptor comprising of a set of attributes of the node is computed. Next, the Multi-Dimensional Scaling (MDS) technique is used to project all the subjects from the unknown graph-space to a low dimensional space based on their inter-graph distance measures. Finally, the Support Vector Machine (SVM) classifier is used on the low dimensional projected space for automatic classification of the ADHD subjects. Exhaustive experimental validation of the proposed method is performed using the data set released for the ADHD-200 competition. Our method shows promise as we achieve impressive classification accuracies on the training (70.49%) and test data sets (73.55%). Our results reveal that the detection rates are higher when classification is performed separately on the male and female groups of subjects.

  13. Attributed graph distance measure for automatic detection of Attention Deficit Hyperactive Disordered subjects

    Soumyabrata eDey

    2014-06-01

    Full Text Available Attention Deficit Hyperactive Disorder (ADHD is getting a lot of attention recently for two reasons. First, it is one of the most commonly found childhood disorders and second, the root cause of the problem is still unknown. Functional Magnetic Resonance Imaging (fMRI data has become a popular tool for the analysis of ADHD, which is the focus of our current research. In this paper we propose a novel framework for the automatic classification of the ADHD subjects using their resting state fMRI (rs-fMRI data of the brain. We construct brain functional connectivity networks for all the subjects. The nodes of the network are constructed with clusters of highly active voxels and edges between any pair of nodes represent the correlations between their average fMRI time series. The activity level of the voxels are measured based on the average power of their corresponding fMRI time-series. For each node of the networks, a local descriptor comprising of a set of attributes of the node is computed. Next, the Multi-Dimensional Scaling (MDS technique is used to project all the subjects from the unknown graph-space to a low dimensional space based on their inter-graph distance measures. Finally, the Support Vector Machine (SVM classifier is used on the low dimensional projected space for automatic classification of the ADHD subjects. Exhaustive experimental validation of the proposed method is performed using the data set released for the ADHD-200 competition. Our method shows promise as we achieve impressive classification accuracies on the training (70.49% and test data sets (73.55%. Our results reveal that the detection rates are higher when classification is performed separately on the male and female groups of subjects.

  14. Spatio-temporal Variations and Source Contributions of China's Premature Deaths Attributable to Ambient PM2.5

    Rong, X.; Wang, H.

    2016-12-01

    With rapid economic growth, China has witnessed increasingly frequent and severe haze and smog episodes over the past decade, posing serious health impacts to the Chinese population, especially those in densely populated city clusters. Quantifications of the spatial and temporal variations of health impacts attributed to ambient fine particulate matter (PM2.5) are not only important for designing effective strategies in mitigating the health damage of air pollution, but also provide valuable references for other developing regions in the world. In this study, we evaluated the spatial distribution of premature deaths in China between 2000 and 2014 attributed to ambient PM2.5 in accord with Global Burden of Disease (GBD) based on a high resolution population density map, satellite retrieved PM2.5 concentration, and provincial health data. An Integrated Exposure Response (IER) model was applied to analyze the premature deaths for four leading causes (ischemic heart disease (IHD), chronic obstructive pulmonary disease (COPD), lung cancer (LC), stroke) in China. The contributions of emission sources to air pollution and related mortality burdens across China were further evaluated by incorporating CMAQ model. Our results suggest that China's anthropogenic ambient PM2.5 led to 1,255,400 premature deaths in 2010, 42% higher than the level in 2000. Besides the increased PM2.5 concentration, rapid urbanization has been attracting large population migration into the more developed eastern coastal urban areas, intensifying the overall health impacts. Our analysis implies that the health burdens were exacerbated in some developing inner provinces with high population density (e.g. Henan, Anhui, Sichuan) because of the relocation of more polluting and resource-intensive industries into these regions. China's regulations on PM2.5 should not be loosened on inner provinces to avoid such national level environmental inequities, and furthermore policies should be designed to form

  15. Attributes identification of nuclear material by non-destructive radiation measurement methods

    Gan Lin

    2002-01-01

    Full text: The nuclear materials should be controlled under the regulation of National Safeguard System. The non-destructive analysis method, which is simple and quick, provide a effective process in determining the nuclear materials, nuclear scraps and wastes. The method play a very important role in the fields of nuclear material control and physical protection against the illegal removal and smuggling of nuclear material. The application of non-destructive analysis in attributes identification of nuclear material is briefly described in this paper. The attributes determined by radioactive detection technique are useful tolls to identify the characterization of special nuclear material (isotopic composition, enrichment etc.). (author)

  16. Black Carbon and Sulfate Aerosols in the Arctic: Long-term Trends, Radiative Impacts, and Source Attributions

    Wang, H.; Zhang, R.; Yang, Y.; Smith, S.; Rasch, P. J.

    2017-12-01

    North America contributed significantly to the overall decreasing trend in Arctic BC and sulfate, especially, in the lower troposphere. The long-term changes in the spatial distributions of aerosols, their radiative impacts and source attributions, along with implications for the Arctic warming trend, will be discussed.

  17. Mobile source air toxics mitigation measures.

    2013-10-01

    In accordance with the Federal Highway Administration (FHWA) Interim Guidance Update on Mobile Source Air Toxic Analysis in NEPA Documents (September 30, 2009), transportation projects subject to the National Environmental Policy Act (NEPA) mus...

  18. Source attribution of human campylobacteriosis at the point of exposure by combining comparative exposure assessment and subtype comparison based on comparative genomic fingerprinting.

    André Ravel

    Full Text Available Human campylobacteriosis is a common zoonosis with a significant burden in many countries. Its prevention is difficult because humans can be exposed to Campylobacter through various exposures: foodborne, waterborne or by contact with animals. This study aimed at attributing campylobacteriosis to sources at the point of exposure. It combined comparative exposure assessment and microbial subtype comparison with subtypes defined by comparative genomic fingerprinting (CGF. It used isolates from clinical cases and from eight potential exposure sources (chicken, cattle and pig manure, retail chicken, beef, pork and turkey meat, and surface water collected within a single sentinel site of an integrated surveillance system for enteric pathogens in Canada. Overall, 1518 non-human isolates and 250 isolates from domestically-acquired human cases were subtyped and their subtype profiles analyzed for source attribution using two attribution models modified to include exposure. Exposure values were obtained from a concurrent comparative exposure assessment study undertaken in the same area. Based on CGF profiles, attribution was possible for 198 (79% human cases. Both models provide comparable figures: chicken meat was the most important source (65-69% of attributable cases whereas exposure to cattle (manure ranked second (14-19% of attributable cases, the other sources being minor (including beef meat. In comparison with other attributions conducted at the point of production, the study highlights the fact that Campylobacter transmission from cattle to humans is rarely meat borne, calling for a closer look at local transmission from cattle to prevent campylobacteriosis, in addition to increasing safety along the chicken supply chain.

  19. Source attribution of human campylobacteriosis at the point of exposure by combining comparative exposure assessment and subtype comparison based on comparative genomic fingerprinting.

    Ravel, André; Hurst, Matt; Petrica, Nicoleta; David, Julie; Mutschall, Steven K; Pintar, Katarina; Taboada, Eduardo N; Pollari, Frank

    2017-01-01

    Human campylobacteriosis is a common zoonosis with a significant burden in many countries. Its prevention is difficult because humans can be exposed to Campylobacter through various exposures: foodborne, waterborne or by contact with animals. This study aimed at attributing campylobacteriosis to sources at the point of exposure. It combined comparative exposure assessment and microbial subtype comparison with subtypes defined by comparative genomic fingerprinting (CGF). It used isolates from clinical cases and from eight potential exposure sources (chicken, cattle and pig manure, retail chicken, beef, pork and turkey meat, and surface water) collected within a single sentinel site of an integrated surveillance system for enteric pathogens in Canada. Overall, 1518 non-human isolates and 250 isolates from domestically-acquired human cases were subtyped and their subtype profiles analyzed for source attribution using two attribution models modified to include exposure. Exposure values were obtained from a concurrent comparative exposure assessment study undertaken in the same area. Based on CGF profiles, attribution was possible for 198 (79%) human cases. Both models provide comparable figures: chicken meat was the most important source (65-69% of attributable cases) whereas exposure to cattle (manure) ranked second (14-19% of attributable cases), the other sources being minor (including beef meat). In comparison with other attributions conducted at the point of production, the study highlights the fact that Campylobacter transmission from cattle to humans is rarely meat borne, calling for a closer look at local transmission from cattle to prevent campylobacteriosis, in addition to increasing safety along the chicken supply chain.

  20. Validation of the Consumer Values versus Perceived Product Attributes Model Measuring the Purchase of Athletic Team Merchandise

    Lee, Donghun; Byon, Kevin K.; Schoenstedt, Linda; Johns, Gary; Bussell, Leigh Ann; Choi, Hwansuk

    2012-01-01

    Various consumer values and perceived product attributes trigger consumptive behaviors of athletic team merchandise (Lee, Trail, Kwon, & Anderson, 2011). Likewise, using a principal component analysis technique on a student sample, a measurement scale was proposed that consisted of nine factors affecting the purchase of athletic team…

  1. Source preparations for alpha and beta measurements

    Holm, E. [Risoe National Lab., Roskilde (Denmark)

    2001-01-01

    Regarding alpha particle emitters subject for environmental studies, electrodeposition or co-precipitation as fluorides are the most common methods. For electro deposition stainless steel is generally used as cathode material but also other metals such as Ni, Ag, and Cu showed promising results. The use of other anode material than platinum, such as graphite should be investigated. For other purposes such as optimal resolution other more sophisticated methods are used but often resulting in poorer recovery. For beta particle emitters the type of detection system will decide the source preparation. Similar methods as for alpha particle emitters, electrodeposition or precipitation techniques can be used. Due to the continuous energy distribution of the beta pulse height distribution a high resolution is not required. Thicker sources from the precipitates or a stable isotopic carrier can be accepted but correction for absorption in the source must be done. (au)

  2. Source attribution using FLEXPART and carbon monoxide emission inventories for the IAGOS In-situ Observation database

    Fontaine, Alain; Sauvage, Bastien; Pétetin, Hervé; Auby, Antoine; Boulanger, Damien; Thouret, Valerie

    2016-04-01

    Since 1994, the IAGOS program (In-Service Aircraft for a Global Observing System http://www.iagos.org) and its predecessor MOZAIC has produced in-situ measurements of the atmospheric composition during more than 46000 commercial aircraft flights. In order to help analyzing these observations and further understanding the processes driving their evolution, we developed a modelling tool SOFT-IO quantifying their source/receptor link. We improved the methodology used by Stohl et al. (2003), based on the FLEXPART plume dispersion model, to simulate the contributions of anthropogenic and biomass burning emissions from the ECCAD database (http://eccad.aeris-data.fr) to the measured carbon monoxide mixing ratio along each IAGOS flight. Thanks to automated processes, contributions are simulated for the last 20 days before observation, separating individual contributions from the different source regions. The main goal is to supply add-value products to the IAGOS database showing pollutants geographical origin and emission type. Using this information, it may be possible to link trends in the atmospheric composition to changes in the transport pathways and to the evolution of emissions. This tool could be used for statistical validation as well as for inter-comparisons of emission inventories using large amounts of data, as Lagrangian models are able to bring the global scale emissions down to a smaller scale, where they can be directly compared to the in-situ observations from the IAGOS database.

  3. Measuring the importance of attributes that influence consumer attitudes to colorectal cancer screening.

    Salkeld, Glenn P; Solomon, Michael J; Short, Leonie; Ward, Jeanette

    2003-03-01

    The aim of the present study was to rate the importance of attributes of screening for bowel cancer. Randomly selected households in central Sydney were contacted to identify men and women aged 50-70 years who were then asked to complete a self-administered questionnaire about bowel cancer screening and related issues. Seven hundred and ninety-one residents (362 men and 429 women) returned questionnaires. Respondents were asked to rate the extent to which each of 34 attributes would encourage them to participate in bowel cancer screening. The three most highly rated attributes were: if the test was recommended by their general practitioner (GP; 94% either 'strongly agreed' or 'agreed'); if the test identified early cancers (92%); and if the test would avert a premature death due to bowel cancer (90%). Having a friend or relative with bowel cancer (61%), advertising (41%) or famous people promoting the program (62%) were less influential. Respondents who were unemployed or on a pension were less likely to participate in screening than those who were employed if there was an 'out of pocket' charge of 15.00 Australian dollars (chi 2 = 7.56, 2df, P = 0.006). Respondents with higher levels of education were significantly more concerned than respondents with lower levels of education about test accuracy (chi 2 = 15.76, 2df, P < 0.001), its availability from their local chemist (chi 2 = 16.96, 2df, P < 0.001), being able to return the test kit by post (chi 2 = 21.9, 2df, P < 0.001) or deposit it with their local chemist (chi 2 = 10.0, 2df, P < 0.01). They were also less likely to be influenced by a famous person promoting bowel cancer screening (chi 2 = 18.87, 2df, P < 0.001). Our results endorse the role of the GP in bowel cancer screening. However, the study also has demonstrated that test accuracy, the convenience of the screening service and notification of test results are valued differently by subgroups in the community, according to their level of education.

  4. Source term measurements on vitrified HLW

    Hough, A.; Marples, J.A.C.

    1988-01-01

    The equilibrium concentrations of Tc-99, Np-237, Pu-239/240 and Am-241 have been measured in the presence of materials likely to be present in a vitrified HLW repository: glass, iron, backfill and rock. Results were measured under both oxidising and reducing conditions and at pH values set by the backfill bentonite and cement. Under reducing conditions and with cementitious backfills, the equilibrium concentrations ranged from three to 30 times allowed drinking water levels for the four isotopes. (author)

  5. Analysis of ozone and nitric acid in spring and summer Arctic pollution using aircraft, ground-based, satellite observations and MOZART-4 model: source attribution and partitioning

    C. Wespes

    2012-01-01

    Full Text Available In this paper, we analyze tropospheric O3 together with HNO3 during the POLARCAT (Polar Study using Aircraft, Remote Sensing, Surface Measurements and Models, of Climate, Chemistry, Aerosols, and Transport program, combining observations and model results. Aircraft observations from the NASA ARCTAS (Arctic Research of the Composition of the Troposphere from Aircraft and Satellites and NOAA ARCPAC (Aerosol, Radiation and Cloud Processes affecting Arctic Climate campaigns during spring and summer of 2008 are used together with the Model for Ozone and Related Chemical Tracers, version 4 (MOZART-4 to assist in the interpretation of the observations in terms of the source attribution and transport of O3 and HNO3 into the Arctic (north of 60° N. The MOZART-4 simulations reproduce the aircraft observations generally well (within 15%, but some discrepancies in the model are identified and discussed. The observed correlation of O3 with HNO3 is exploited to evaluate the MOZART-4 model performance for different air mass types (fresh plumes, free troposphere and stratospheric-contaminated air masses.

    Based on model simulations of O3 and HNO3 tagged by source type and region, we find that the anthropogenic pollution from the Northern Hemisphere is the dominant source of O3 and HNO3 in the Arctic at pressures greater than 400 hPa, and that the stratospheric influence is the principal contribution at pressures less 400 hPa. During the summer, intense Russian fire emissions contribute some amount to the tropospheric columns of both gases over the American sector of the Arctic. North American fire emissions (California and Canada also show an important impact on tropospheric ozone in the Arctic boundary layer.

    Additional analysis of tropospheric O3 measurements from ground-based FTIR and from the IASI satellite sounder made

  6. Microflown based monopole sound sources for reciprocal measurements

    Bree, H.E. de; Basten, T.G.H.

    2008-01-01

    Monopole sound sources (i.e. omni directional sound sources with a known volume velocity) are essential for reciprocal measurements used in vehicle interior panel noise contribution analysis. Until recently, these monopole sound sources use a sound pressure transducer sensor as a reference sensor. A

  7. Evaluation of Sources of Uncertainties in Solar Resource Measurement

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sengupta, Manajit [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-25

    This poster presents a high-level overview of sources of uncertainties in solar resource measurement, demonstrating the impact of various sources of uncertainties -- such as cosine response, thermal offset, spectral response, and others -- on the accuracy of data from several radiometers. The study provides insight on how to reduce the impact of some of the sources of uncertainties.

  8. The magnet measurement facility for the Advanced Photon Source

    Kim, S.H.; Doose, C.; Hogrefe, R.; Kim, K.; Merl, R.

    1993-01-01

    A magnet measurement facility has been developed to measure the prototype and production magnets for the Advance Photon Source. The measurement facility is semi-automatic in measurement control and data analysis. One dipole system and three rotating coil measurement systems for quadrupole and sextupole magnets and corresponding probe coils are described

  9. Procedures for measurement of anisotropy factor of neutron sources

    Creazolla, P.G.; Camargo, A.; Astuto, A.; Silva, F.; Pereira, W.W.

    2017-01-01

    Radioisotope sources of neutrons allow the production of reference fields for calibration of neutron measurement devices for radioprotection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in the source capsule material and variations in the concentration of the emitting material may produce differences in its neutron emission rate relative to the source axis, this effect is called anisotropy. A proposed procedure for measuring the anisotropy factor of the sources belonging to the IRD/LNMRI/LN Neutron Metrology Laboratory using a Precision Long Counter (PLC) detector will be presented

  10. Human Campylobacteriosis in Luxembourg, 2010-2013: A Case-Control Study Combined with Multilocus Sequence Typing for Source Attribution and Risk Factor Analysis.

    Mossong, Joël; Mughini-Gras, Lapo; Penny, Christian; Devaux, Anthony; Olinger, Christophe; Losch, Serge; Cauchie, Henry-Michel; van Pelt, Wilfrid; Ragimbeau, Catherine

    2016-02-10

    Campylobacteriosis has increased markedly in Luxembourg during recent years. We sought to determine which Campylobacter genotypes infect humans, where they may originate from, and how they may infect humans. Multilocus sequence typing was performed on 1153 Campylobacter jejuni and 136 C. coli human strains to be attributed to three putative animal reservoirs (poultry, ruminants, pigs) and to environmental water using the asymmetric island model. A nationwide case-control study (2010-2013) for domestic campylobacteriosis was also conducted, including 367 C. jejuni and 48 C. coli cases, and 624 controls. Risk factors were investigated by Campylobacter species, and for strains attributed to different sources using a combined case-control and source attribution analysis. 282 sequence types (STs) were identified: ST-21, ST-48, ST-572, ST-50 and ST-257 were prevailing. Most cases were attributed to poultry (61.2%) and ruminants (33.3%). Consuming chicken outside the home was the dominant risk factor for both Campylobacter species. Newly identified risk factors included contact with garden soil for either species, and consuming beef specifically for C. coli. Poultry-associated campylobacteriosis was linked to poultry consumption in wintertime, and ruminant-associated campylobacteriosis to tap-water provider type. Besides confirming chicken as campylobacteriosis primary source, additional evidence was found for other reservoirs and transmission routes.

  11. Questionnaire for measuring organisational attributes in dental-care practices: psychometric properties and test-retest reliability.

    Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M

    2016-04-01

    The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.

  12. The OpenPMU Platform for Open Source Phasor Measurements

    Laverty, David M.; Best, Robert J.; Brogan, Paul; Al-Khatib, Iyad; Vanfretti, Luigi; Morrow, D John

    2013-01-01

    OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. Th...

  13. Data format standard for sharing light source measurements

    Gregory, G. Groot; Ashdown, Ian; Brandenburg, Willi; Chabaud, Dominique; Dross, Oliver; Gangadhara, Sanjay; Garcia, Kevin; Gauvin, Michael; Hansen, Dirk; Haraguchi, Kei; Hasna, Günther; Jiao, Jianzhong; Kelley, Ryan; Koshel, John; Muschaweck, Julius

    2013-09-01

    Optical design requires accurate characterization of light sources for computer aided design (CAD) software. Various methods have been used to model sources, from accurate physical models to measurement of light output. It has become common practice for designers to include measured source data for design simulations. Typically, a measured source will contain rays which sample the output distribution of the source. The ray data must then be exported to various formats suitable for import into optical analysis or design software. Source manufacturers are also making measurements of their products and supplying CAD models along with ray data sets for designers. The increasing availability of data has been beneficial to the design community but has caused a large expansion in storage needs for the source manufacturers since each software program uses a unique format to describe the source distribution. In 2012, the Illuminating Engineering Society (IES) formed a working group to understand the data requirements for ray data and recommend a standard file format. The working group included representatives from software companies supplying the analysis and design tools, source measurement companies providing metrology, source manufacturers creating the data and users from the design community. Within one year the working group proposed a file format which was recently approved by the IES for publication as TM-25. This paper will discuss the process used to define the proposed format, highlight some of the significant decisions leading to the format and list the data to be included in the first version of the standard.

  14. Risk factors for campylobacteriosis of chicken, ruminant, and environmental origin: a combined case-control and source attribution analysis

    Mughini Gras, L.|info:eu-repo/dai/nl/413306046; Smid, J.H.|info:eu-repo/dai/nl/313996458; Wagenaar, J.A.|info:eu-repo/dai/nl/126613354; de Boer, A.G.; Havelaar, A.H.|info:eu-repo/dai/nl/072306122; Friesema, I.H.M.; French, N.P.; Busani, L.; van Pelt, W.

    2012-01-01

    BACKGROUND Campylobacteriosis contributes strongly to the disease burden of food-borne pathogens. Case-control studies are limited in attributing human infections to the different reservoirs because they can only trace back to the points of exposure, which may not point to the original reservoirs

  15. Risk Factors for Campylobacteriosis of Chicken, Ruminant, and Environmental Origin: A Combined Case-Control and Source Attribution Analysis

    Gras, L.M.; Smid, J.H.; Wagenaar, J.A.; Boer, de A.G.; Havelaar, A.H.; Friesema, I.H.M.; French, N.P.; Busani, L.; Pelt, van W.

    2012-01-01

    Background: Campylobacteriosis contributes strongly to the disease burden of food-borne pathogens. Case-control studies are limited in attributing human infections to the different reservoirs because they can only trace back to the points of exposure, which may not point to the original reservoirs

  16. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis

    Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.

    2016-01-01

    Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker

  17. Attribution of Human Listeria monocytogenes Infections in England and Wales to Ready-to-Eat Food Sources Placed on the Market: Adaptation of the Hald Salmonella Source Attribution Model

    Little, Christine L.; Pires, Sara Monteiro; Gillespie, Iain A.

    2010-01-01

    the potential of this approach to quantify the contribution of different food sources to the burden of human listeriosis in England and Wales from 2004 to 2007. The most important food sources for the overall population were multicomponent foods (sandwiches and prepacked mixed salad vegetables) (23.1%), finfish...

  18. Comparison of Laser and Stereo Optical, SAR and InSAR Point Clouds from Air- and Space-Borne Sources in the Retrieval of Forest Inventory Attributes

    Xiaowei Yu

    2015-11-01

    Full Text Available It is anticipated that many of the future forest mapping applications will be based on three-dimensional (3D point clouds. A comparison study was conducted to verify the explanatory power and information contents of several 3D remote sensing data sources on the retrieval of above ground biomass (AGB, stem volume (VOL, basal area (G, basal-area weighted mean diameter (Dg and Lorey’s mean height (Hg at the plot level, utilizing the following data: synthetic aperture radar (SAR Interferometry, SAR radargrammetry, satellite-imagery having stereo viewing capability, airborne laser scanning (ALS with various densities (0.8–6 pulses/m2 and aerial stereo imagery. Laser scanning is generally known as the primary source providing a 3D point cloud. However, photogrammetric, radargrammetric and interferometric techniques can be used to produce 3D point clouds from space- and air-borne stereo images. Such an image-based point cloud could be utilized in a similar manner as ALS providing that accurate digital terrain model is available. In this study, the performance of these data sources for providing point cloud data was evaluated with 91 sample plots that were established in Evo, southern Finland within a boreal forest zone and surveyed in 2014 for this comparison. The prediction models were built using random forests technique with features derived from each data sources as independent variables and field measurements of forest attributes as response variable. The relative root mean square errors (RMSEs varied in the ranges of 4.6% (0.97 m–13.4% (2.83 m for Hg, 11.7% (3.0 cm–20.6% (5.3 cm for Dg, 14.8% (4.0 m2/ha–25.8% (6.9 m2/ha for G, 15.9% (43.0 m3/ha–31.2% (84.2 m3/ha for VOL and 14.3% (19.2 Mg/ha–27.5% (37.0 Mg/ha for AGB, respectively, depending on the data used. Results indicate that ALS data achieved the most accurate estimates for all forest inventory attributes. For image-based 3D data, high-altitude aerial images and WorldView-2

  19. Cross Entropy Measures of Bipolar and Interval Bipolar Neutrosophic Sets and Their Application for Multi-Attribute Decision-Making

    Surapati Pramanik

    2018-03-01

    Full Text Available The bipolar neutrosophic set is an important extension of the bipolar fuzzy set. The bipolar neutrosophic set is a hybridization of the bipolar fuzzy set and neutrosophic set. Every element of a bipolar neutrosophic set consists of three independent positive membership functions and three independent negative membership functions. In this paper, we develop cross entropy measures of bipolar neutrosophic sets and prove their basic properties. We also define cross entropy measures of interval bipolar neutrosophic sets and prove their basic properties. Thereafter, we develop two novel multi-attribute decision-making strategies based on the proposed cross entropy measures. In the decision-making framework, we calculate the weighted cross entropy measures between each alternative and the ideal alternative to rank the alternatives and choose the best one. We solve two illustrative examples of multi-attribute decision-making problems and compare the obtained result with the results of other existing strategies to show the applicability and effectiveness of the developed strategies. At the end, the main conclusion and future scope of research are summarized.

  20. [A multi-measure analysis of the similarity, attraction, and compromise effects in multi-attribute decision making].

    Tsuzuki, Takashi; Matsui, Hiroshi; Kikuchi, Manabu

    2012-12-01

    In multi-attribute decision making, the similarity, attraction, and compromise effects warrant specific investigation as they cause violations of principles in rational choice. In order to investigate these three effects simultaneously, we assigned 145 undergraduates to three context effect conditions. We requested them to solve the same 20 hypothetical purchase problems, each of which had three alternatives described along two attributes. We measured their choices, confidence ratings, and response times. We found that manipulating the third alternative had significant context effects for choice proportions and confidence ratings in all three conditions. Furthermore, the attraction effect was the most prominent with regard to choice proportions. In the compromise effect condition, although the choice proportion of the third alternative was high, the confidence rating was low and the response time was long. These results indicate that the relationship between choice proportions and confidence ratings requires further theoretical investigation. They also suggest that a combination of experimental and modeling studies is imperative to reveal the mechanisms underlying the context effects in multi-attribute, multi-alternative decision making.

  1. Fission Meter Information Barrier Attribute Measurement System: Task 1 Report: Document existing Fission Meter neutron IB system

    Kerr, P. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-28

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements in a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.

  2. Fission Meter Information Barrier Attribute Measurement System - NA-243 FNI/UKC FY2017 Task 1-2 Report

    Kerr, P. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Decman, D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Prasad, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Castro, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-03

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements in a way the does not reveal sensitive information. In full IB mode, only the pass/fail result is displayed as a “Mass <= Threshold Amount” or “Mass >= Threshold Amount” as shown in Figure 4. This can easily be adapted to a red/green “lights” display similar to the Detective IB system for Pu isotopics as shown in Figure 6. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.

  3. Attribution of aerosol radiative forcing over India during the winter monsoon to emissions from source categories and geographical regions

    Verma, S.; Venkataraman, C.; Boucher, O.

    2011-08-01

    We examine the aerosol radiative effects due to aerosols emitted from different emission sectors (anthropogenic and natural) and originating from different geographical regions within and outside India during the northeast (NE) Indian winter monsoon (January-March). These studies are carried out through aerosol transport simulations in the general circulation (GCM) model of the Laboratoire de Météorologie Dynamique (LMD). The model estimates of aerosol single scattering albedo (SSA) show lower values (0.86-0.92) over the region north to 10°N comprising of the Indian subcontinent, Bay of Bengal, and parts of the Arabian Sea compared to the region south to 10°N where the estimated SSA values lie in the range 0.94-0.98. The model estimated SSA is consistent with the SSA values inferred through measurements on various platforms. Aerosols of anthropogenic origin reduce the incoming solar radiation at the surface by a factor of 10-20 times the reduction due to natural aerosols. At the top-of-atmosphere (TOA), aerosols from biofuel use cause positive forcing compared to the negative forcing from fossil fuel and natural sources in correspondence with the distribution of SSA which is estimated to be the lowest (0.7-0.78) from biofuel combustion emissions. Aerosols originating from India and Africa-west Asia lead to the reduction in surface radiation (-3 to -8 W m -2) by 40-60% of the total reduction in surface radiation due to all aerosols over the Indian subcontinent and adjoining ocean. Aerosols originating from India and Africa-west Asia also lead to positive radiative effects at TOA over the Arabian Sea, central India (CNI), with the highest positive radiative effects over the Bay of Bengal and cause either negative or positive effects over the Indo-Gangetic plain (IGP).

  4. Measuring Conflict in a Multi-Source Environment as a Normal Measure

    Wei, Pan; Ball, John E.; Anderson, Derek T.; Harsh, Archit; Archibald, Christopher

    2018-01-01

    In a multi-source environment, each source has its own credibility. If there is no external knowledge about credibility then we can use the information provided by the sources to assess their credibility. In this paper, we propose a way to measure conflict in a multi-source environment as a normal measure. We examine our algorithm using three simulated examples of increasing conflict and one experimental example. The results demonstrate that the proposed measure can represent conflict in a me...

  5. Development of the multi-attribute Adolescent Health Utility Measure (AHUM

    Beusterien Kathleen M

    2012-08-01

    Full Text Available Abstract Objective Obtain utilities (preferences for a generalizable set of health states experienced by older children and adolescents who receive therapy for chronic health conditions. Methods A health state classification system, the Adolescent Health Utility Measure (AHUM, was developed based on generic health status measures and input from children with Hunter syndrome and their caregivers. The AHUM contains six dimensions with 4–7 severity levels: self-care, pain, mobility, strenuous activities, self-image, and health perceptions. Using the time trade off (TTO approach, a UK population sample provided utilities for 62 of 16,800 AHUM states. A mixed effects model was used to estimate utilities for the AHUM states. The AHUM was applied to trial NCT00069641 of idursulfase for Hunter syndrome and its extension (NCT00630747. Results Observations (i.e., utilities totaled 3,744 (12*312 participants, with between 43 to 60 for each health state except for the best and worst states which had 312 observations. The mean utilities for the best and worst AHUM states were 0.99 and 0.41, respectively. The random effects model was statistically significant (p  Discussion The AHUM health state classification system may be used in future research to enable calculation of quality-adjust life expectancy for applicable health conditions.

  6. Application research of tune measurement system in Hefei light source

    Sun Baogen; He Duohui; Xu Hongliang; Lu Ping; Wang Junhua; Gao Yunfeng; Wang Lin; Liu Jinying

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  7. Procedure for measurement of anisotropy factor for neutron sources

    Creazolla, Prycylla Gomes

    2017-01-01

    Radioisotope neutron sources allow the production of reference fields for calibration of neutron detectors for radiation protection and analysis purposes. When the emission rate of these sources is isotropic, no correction is necessary. However, variations in source encapsulation and in the radioactive material concentration produce differences in its neutron emission rate, relative to the source axis, this effect is called anisotropy. In this study, is describe a procedure for measuring the anisotropy factor of neutron sources performed in the Laboratório de Metrologia de Neutrons (LN) using a Precision Long Counter (PLC) detector. A measurement procedure that takes into account the anisotropy factor of neutron sources contributes to solve some issues, particularly with respect to the high uncertainties associated with neutron dosimetry. Thus, a bibliographical review was carried out based on international standards and technical regulations specific to the area of neutron fields, and were later reproduced in practice by means of the procedure for measuring the anisotropy factor in neutron sources of the LN. The anisotropy factor is determined as a function of the angle of 90° in relation to the cylindrical axis of the source. This angle is more important due to its high use in measurements and also of its higher neutron emission rate if compared with other angles. (author)

  8. Risk factors for human salmonellosis originating from pigs, cattle, broiler chickens and egg laying hens: a combined case-control and source attribution analysis.

    Lapo Mughini-Gras

    Full Text Available Several case-control studies have investigated risk factors for human salmonellosis while others have used Salmonella subtyping to attribute human infections to different food and animal reservoirs. This study combined case-control and source attribution data into a single analysis to explore risk factors at the point of exposure for human salmonellosis originating from four putative food-producing animal reservoirs (pigs, cattle, broilers and layers/eggs in the Netherlands. We confirmed that most human cases (∼ 90% were attributable to layers/eggs and pigs. Layers/eggs and broilers were the most likely reservoirs of salmonellosis in adults, in urban areas, and in spring/summer, whereas pigs and cattle were the most likely reservoirs of salmonellosis in children, in rural areas, and in autumn/winter. Several reservoir-specific risk factors were identified. Not using a chopping board for raw meat only and consuming raw/undercooked meat were risk factors for infection with salmonellas originating from pigs, cattle and broilers. Consuming raw/undercooked eggs and by-products were risk factors for layer/egg-associated salmonellosis. Using antibiotics was a risk factor for pig- and cattle-associated salmonellosis and using proton-pump inhibitors for salmonellosis attributable to any reservoir. Pig- and cattle-associated infections were also linked to direct contact with animals and environmental exposure (e.g. playing in sandboxes. Eating fish, meat in pastry, and several non-meat foods (fruit, vegetables and pasteurized dairy products were protective factors. Consuming pork and occupational exposure to animals and/or raw meats were protective against layer/egg-associated salmonellosis. We concluded that individuals acquiring salmonellosis from different reservoirs have different associated risk factors, suggesting that salmonellas may infect humans through various transmission pathways depending on their original reservoirs. The outcome of

  9. Risk Factors for Human Salmonellosis Originating from Pigs, Cattle, Broiler Chickens and Egg Laying Hens: A Combined Case-Control and Source Attribution Analysis

    Mughini-Gras, Lapo; Enserink, Remko; Friesema, Ingrid; Heck, Max; van Duynhoven, Yvonne; van Pelt, Wilfrid

    2014-01-01

    Several case-control studies have investigated risk factors for human salmonellosis while others have used Salmonella subtyping to attribute human infections to different food and animal reservoirs. This study combined case-control and source attribution data into a single analysis to explore risk factors at the point of exposure for human salmonellosis originating from four putative food-producing animal reservoirs (pigs, cattle, broilers and layers/eggs) in the Netherlands. We confirmed that most human cases (∼90%) were attributable to layers/eggs and pigs. Layers/eggs and broilers were the most likely reservoirs of salmonellosis in adults, in urban areas, and in spring/summer, whereas pigs and cattle were the most likely reservoirs of salmonellosis in children, in rural areas, and in autumn/winter. Several reservoir-specific risk factors were identified. Not using a chopping board for raw meat only and consuming raw/undercooked meat were risk factors for infection with salmonellas originating from pigs, cattle and broilers. Consuming raw/undercooked eggs and by-products were risk factors for layer/egg-associated salmonellosis. Using antibiotics was a risk factor for pig- and cattle-associated salmonellosis and using proton-pump inhibitors for salmonellosis attributable to any reservoir. Pig- and cattle-associated infections were also linked to direct contact with animals and environmental exposure (e.g. playing in sandboxes). Eating fish, meat in pastry, and several non-meat foods (fruit, vegetables and pasteurized dairy products) were protective factors. Consuming pork and occupational exposure to animals and/or raw meats were protective against layer/egg-associated salmonellosis. We concluded that individuals acquiring salmonellosis from different reservoirs have different associated risk factors, suggesting that salmonellas may infect humans through various transmission pathways depending on their original reservoirs. The outcome of classical case

  10. Racial Residential Segregation: Measuring Location Choice Attributes of Environmental Quality and Self-Segregation

    Zhaohua Zhang

    2018-04-01

    Full Text Available Both sorting on public goods and tastes for segregation contribute to the persistence of segregation in America. Incorporating Schelling’s (1969, 1971 concept of “neighborhood tipping” into a two-stage equilibrium sorting model, in which both neighborhood demographic composition and public goods (e.g., environmental quality affect households’ residential location choice, this study investigates how preferences for neighborhood demographic composition could obscure the role of exogenous public goods on segregation. The results reveal that non-white households face higher level of exposure to air pollution, suggesting the presence of environmental injustice in Franklin County, OH. Using a counterfactual scenario of switching off heterogeneous taste for environmental quality, this study identifies that sorting on Toxic Release Inventory (TRI emissions drives little correlations between emissions and demographics. However, when taste parameters of the interactions between neighborhood demographic composition and household race are eliminated, segregation (as measured by over-exposure to households of the same race of black and white households decreases by 7.63% and 16.36%, respectively, and own-race neighbor preferences contribute to segregation differently according to household income. These results may help explain some recent puzzles in the relationship between environmental quality and demographics.

  11. Global Scale Attribution of Anthropogenic and Natural Dust Sources and their Emission Rates Based on MODIS Deep Blue Aerosol Products

    Ginoux, Paul; Prospero, Joseph M.; Gill, Thomas E.; Hsu, N. Christina; Zhao, Ming

    2012-01-01

    Our understanding of the global dust cycle is limited by a dearth of information about dust sources, especially small-scale features which could account for a large fraction of global emissions. Here we present a global-scale high-resolution (0.1 deg) mapping of sources based on Moderate Resolution Imaging Spectroradiometer (MODIS) Deep Blue estimates of dust optical depth in conjunction with other data sets including land use. We ascribe dust sources to natural and anthropogenic (primarily agricultural) origins, calculate their respective contributions to emissions, and extensively compare these products against literature. Natural dust sources globally account for 75% of emissions; anthropogenic sources account for 25%. North Africa accounts for 55% of global dust emissions with only 8% being anthropogenic, mostly from the Sahel. Elsewhere, anthropogenic dust emissions can be much higher (75% in Australia). Hydrologic dust sources (e.g., ephemeral water bodies) account for 31% worldwide; 15% of them are natural while 85% are anthropogenic. Globally, 20% of emissions are from vegetated surfaces, primarily desert shrublands and agricultural lands. Since anthropogenic dust sources are associated with land use and ephemeral water bodies, both in turn linked to the hydrological cycle, their emissions are affected by climate variability. Such changes in dust emissions can impact climate, air quality, and human health. Improved dust emission estimates will require a better mapping of threshold wind velocities, vegetation dynamics, and surface conditions (soil moisture and land use) especially in the sensitive regions identified here, as well as improved ability to address small-scale convective processes producing dust via cold pool (haboob) events frequent in monsoon regimes.

  12. Laser driven white light source for BRDF measurement

    Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    In this paper, we will present a setup with laser driven light source (LDLS) for measuring a 2D bidirectional reflectance distribution function (BRDF). We have carried out measurements to acquire the BRDF of different samples based on our setup: which consists of a new laser driven broadband light...... source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...

  13. The Sanskrit and Arabic Sources of the Praśnatantra Attributed to Nīlakaṇṭha

    Martin Gansten

    2014-12-01

    Full Text Available The highly popular Praśnatantra attributed to Nīlakaṇṭha of Kāśī (fl. late 16th century and sometimes regarded as the third volume of his Tājikanīlakaṇṭhī is shown to depend for its basic structure on an abridged Sanskrit version of the Kitāb fi l-masāʾil wa-l-aḥkām by Sahl ibn Bishr (early 9th century, apparently authored by Samarasiṃha in the 13th century, to which quotations primarily from Sanskrit astrological works in the classical Indian style have been added, resulting in a hybrid of Indian and Perso-Arabic interrogational astrology.

  14. The attribution of human infections with antimicrobial resistant Salmonella bacteria in Denmark to sources of animal origin

    Hald, Tine; Lo Fo Wong, Danilo M. A.; Aarestrup, Frank Møller

    2007-01-01

    Based on the Danish Salmonella surveillance in 2000-2001, we developed a mathematical model for quantifying the contribution of each major animal-food sources to human salmonellosis caused by antimicrobial resistant bacteria. Domestic food products accounted for 53.1% of all cases, mainly caused......, but infections with multidrug- and quinolone-resistant isolates were more commonly caused by imported food products and travelling, emphasizing the need for a global perspective on food safety and antimicrobial usage....... by table eggs (37.6%). A large proportion (19%) of cases were travel related, while 18% could not be associated with any source. Imported food products accounted for 9.5% of all cases; the most important source being imported chicken. Multidrug and quinolone resistance was rarely found in cases acquired...

  15. Residual stress measurement using the pulsed neutron source at LANSCE

    Bourke, M.A.M.; Goldstone, J.A.; Holden, T.M.

    1991-01-01

    The presence of residual stress in engineering components can effect their mechanical properties and structural integrity. Neutron diffraction is the only measuring technique which can make spatially resolved non-destructive strain measurements in the interior of components. By recording the change in the crystalline interplanar spacing, elastic strains can be measured for individual lattice reflections. Using a pulsed neutron source, all the lattice reflections are recorded in each measurement which allows anisotropic effects to be studied. Measurements made at the Manuel Lujan Jr Neutron Scattering Centre (LANSCE) demonstrate the potential for stress measurements on a pulsed source and indicate the advantages and disadvantages over measurements made on a reactor. 15 refs., 7 figs

  16. Source attribution of human salmonellosis using a meta-analysis of case-control studies of sporadic infections

    Coutinho Calado Domingues, Ana Rita; Pires, Sara Monteiro; Hisham Beshara Halasa, Tariq

    2012-01-01

    Salmonella is an important cause of human illness. Disease is frequently associated with foodborne transmission, but other routes of exposure are recognized. Identifying sources of disease is essential for prioritizing public health interventions. Numerous case-control studies of sporadic salmone...

  17. The use of Pb, Sr, and Hg isotopes in Great Lakes precipitation as a tool for pollution source attribution

    The anthropogenic emission and subsequent deposition of heavy metals including mercury (Hg) and lead (Pb) presents human health and environmental concerns. Although it is known that local and regional sources of these metals contribute to deposition in the Great Lakes region, it ...

  18. Use of on-ground gamma-ray spectrometry to measure plant-available potassium and other topsoil attributes

    Wong, M.T.F.; Harper, R.J.

    1999-01-01

    The incidence of potassium (K) deficiency is increasing in crops, pastures, and forestry in south-western Australia. Although soil K can be measured using soil sampling and analysis, γ-ray spectrometry offers a potentially cheaper and spatially more precise alternative. This could be particularly useful in precision agriculture, where inputs are applied according to need rather than by general prescription. In a study of topsoils near Jerramungup, Western Australia, strong relationships (r 2 = 0.9) were found between on-ground counts of γ-rays derived from 40 K (γ-K) and both total K and plant-available K. The success of γ-ray spectrometry in predicting available K relied on a strong relationship (r 2 0.9) between total K and available K which may not hold in all areas. Although the relationship between γ-K and available K held over the range of 36-1012 mg/kg, crop response to K fertilisers is only expected when the available K content is 2 = 0.9) were also found between γ-K and a range of other soil attributes, including clay, silt, and organic carbon content. These relationships depended on the locally strong relationship between total K and these soil attributes. Since such relationships do not hold everywhere, the utility of γ-ray spectrometry will likewise be limited. Site-specific calibrations are required if γ-ray spectrometry is to be used for soil property mapping. Copyright (1999) CSIRO Publishing

  19. Purslane weed (Portulaca oleracea): a prospective plant source of nutrition, omega-3 fatty acid, and antioxidant attributes.

    Uddin, Md Kamal; Juraimi, Abdul Shukor; Hossain, Md Sabir; Nahar, Most Altaf Un; Ali, Md Eaqub; Rahman, M M

    2014-01-01

    Purslane (Portulaca oleracea L.) is an important plant naturally found as a weed in field crops and lawns. Purslane is widely distributed around the globe and is popular as a potherb in many areas of Europe, Asia, and the Mediterranean region. This plant possesses mucilaginous substances which are of medicinal importance. It is a rich source of potassium (494 mg/100 g) followed by magnesium (68 mg/100 g) and calcium (65 mg/100 g) and possesses the potential to be used as vegetable source of omega-3 fatty acid. It is very good source of alpha-linolenic acid (ALA) and gamma-linolenic acid (LNA, 18 : 3 w3) (4 mg/g fresh weight) of any green leafy vegetable. It contained the highest amount (22.2 mg and 130 mg per 100 g of fresh and dry weight, resp.) of alpha-tocopherol and ascorbic acid (26.6 mg and 506 mg per 100 g of fresh and dry weight, resp.). The oxalate content of purslane leaves was reported as 671-869 mg/100 g fresh weight. The antioxidant content and nutritional value of purslane are important for human consumption. It revealed tremendous nutritional potential and has indicated the potential use of this herb for the future.

  20. Low noise constant current source for bias dependent noise measurements

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  1. Preparation of protactinium measurement source by electroplating method

    Li Zongwei; Yang Weifan; Fang Keming; Yuan Shuanggui; Guo Junsheng; Pan Qiangyan

    1998-01-01

    An electroplating method for the preparation of Pa sources is described, and the main factors (such as pH value of solution, electroplating time and current density) influencing the electroplating of Pa are tested and discussed with 233 Pa as a tracer. A thin and uniform electroplating Pa-Layer of 1 mg/cm 2 thick on thin stainless steel disk was obtained. The Pa source was measured by a HPGe detector to determine the chemical efficiency

  2. Ion implanted Na22 source for positron lifetime measurements

    Fluss, M.J.; Smedeskjaer, L.C.

    1979-04-01

    A new positron source-sample fabrication technique, intended for high temperature positron annihilation measurements, was developed. The method makes use of a mass separator to implant pure Na 22 into the sample surface. The application of this technique to Cu is described. A brief discussion of the origin of the source component is given, and different possibilities of correcting for it are pointed out. 3 references

  3. Development of a questionnaire to measure the key attributes of the community palliative care specialist nurse role.

    Cameron, Dee; Johnston, Bridget

    2015-02-01

    Recent worldwide economic events have forced an examination of the nurse's contribution to high-quality, effective, person-centred care. Since the role of specialist nurses is considered one of the least understood or valued developments in nursing, specialist nurses must demonstrate their contribution to quality, person-centred health care. To develop a questionnaire which aims to measure the quality of care provided by palliative care specialist nurses from the patients' perspective and to undertake initial validation. The process of questionnaire development involved six phases including systematic literature reviews, patient advisory groups and expert panel reviews, each of which contributed to the questionnaire face and content validity. Johnston's Expert Palliative Care Nurse Model (2002; 2005) provided an evidence-based framework for the development of the questionnaire, and enabled the identification of the key attributes of the palliative care specialist nurse role, thereby providing the themes on which to base the questionnaire. The Quality Measure for Palliative Nursing, a questionnaire, was developed. The themes identified in the questionnaire--personal characteristics, communication skills, knowledge, relationship with patient and providing comfort--aim to facilitate measurement of the quality of care provided by palliative care specialist nurses. Designed for use by palliative patients the Quality Measure for Palliative Nursing is a one-page questionnaire comprising of 15 questions. The Quality Measure for Palliative Nursing is unique since it aims to measure the quality of care provided by community palliative care specialist nurses, and could also be used to measure patient satisfaction with the quality of care provided. Further testing is recommended to ensure that this questionnaire can provide reliable and valid results.

  4. From digital earth to digital neighbourhood: A study of subjective measures of walkability attributes in objectively assessed digital neighbourhood

    Qureshi, S; Ho, C S

    2014-01-01

    According to IEA report (2011), about 23% of the World's CO 2 emissions result from transport and this is one of the few areas where emissions are still rapidly increasing. The use of private vehicles is one of the principle contributors to green house gas emissions from transport sector. Therefore this paper focuses on the shift to more sustainable and low carbon forms of transportation mode such as walking. Neighbourhood built environment attributes may influence walkability. For this study, the author used a modified version of the ''Neighbourhood Environment Walkability Scale'' to make comparison between respondents' perceptions regarding attributes of two neighborhoods of Putrajaya. The 21st Century really needs planners to use the Digital Earth Concept, to go from global to regional to national to very local issues, using integrated, advanced technologies such as earth observation, GIS, virtual reality, etc. For this research, two (2) neighborhoods of different densities (High and Low density) were selected. A sample total of 381(195 and 186) between 7 to 65 years old participants were selected For subjective measures we used 54 questions questionnaire survey where as for the objective measures we used desktop 9.3 version of Arc GIS soft ware. Our results shows that respondents who reside in high-walkable neighbourhood precinct 9 in Putrajaya rated factors such as residential density, land use mix, proximity to destination and street connectivity, consistently higher then did respondents of the low walkable neighbourhood precinct 8 in Putrajaya

  5. Use of β-ray source for measurement of adsorption

    Kawakami, Hirokane; Nishimura, Keigo; Oshima, Takayoshi

    1987-01-01

    A research project has been carried out with the goal of determining the mass of a neutrino from β-decay measurements. During a study seeking the development of a β-ray source for this purpose, it was found that the amount of residual gas adsorbed on a cooled β-ray source can be measured successfully. Electrons emitted from a β-ray source is measured by an electron spectrometer. A sharp, nearly symmetric peak is obtained if all electrons have the same energy. If gas is adsorbed on the surface of the source, on the other hand, the resultant spectrum has a rather different profile due to energy loss caused by the gas. The difference between the energy loss spectrum and the original spectrum must be proportional to the amount of the adsorbed gas. In this study, a 109 Cd source with an electron energy peak at 18 keV is selected and the number of molecules adsorbed on the source, cooled to -35 deg C at 5 x 10 -7 Torr, is determined. Assuming that the gas is water vapor, it is shown that the adsorbed layer is of a two-molecular thickness on the average. It is also found that the thickness is reversible at varrying temperatures and does not change for two days. This gas amount is 7,500 time as large as that in the case of physical adsorption of water. (Nogami, K.)

  6. Radioactive Sources in Medicine: Impact of Additional Security Measures

    Classic, K. L.; Vetter, R. J.; Nelson, K. L.

    2004-01-01

    For many years, medical centers and hospitals have utilized appropriate security measures to prevent theft or unauthorized use of radioactive materials. Recent anxiety about orphan sources and terrorism has heightened concern about diversion of radioactive sources for purposes of constructing a radiological dispersion device. Some medical centers and hospitals may have responded by conducting threat assessments and incorporating additional measures into their security plans, but uniform recommendations or regulations have not been promulgated by regulatory agencies. The International Atomic Energy Agency drafted interim guidance for the purpose of assisting member states in deciding what security measures should be taken for various radioactive sources. The recommendations are aimed at regulators, but suppliers and users also may find the recommendations to be helpful. The purpose of this paper is to describe threat assessments and additional security actions that were taken by one large and one medium-sized medical center and the impact these measures had on operations. Both medical centers possess blood bank irradiators, low-dose-rate therapy sources, and Mo-99/Tc-99m generators that are common to many health care organizations. Other medical devices that were evaluated include high-dose-rate after loaders, intravascular brachytherapy sources, a Co-60 stereotactic surgery unit, and self-shielded irradiators used in biomedical research. This paper will discuss the impact additional security has had on practices that utilize these sources, cost of various security alternatives, and the importance of a security culture in assuring the integrity of security measures without negatively impacting beneficial use of these sources. (Author) 10 refs

  7. Inversion of Atmospheric Tracer Measurements, Localization of Sources

    Issartel, J.-P.; Cabrit, B.; Hourdin, F.; Idelkadi, A.

    When abnormal concentrations of a pollutant are observed in the atmosphere, the question of its origin arises immediately. The radioactivity from Tchernobyl was de- tected in Sweden before the accident was announced. This situation emphasizes the psychological, political and medical stakes of a rapid identification of sources. In tech- nical terms, most industrial sources can be modeled as a fixed point at ground level with undetermined duration. The classical method of identification involves the cal- culation of a backtrajectory departing from the detector with an upstream integration of the wind field. We were first involved in such questions as we evaluated the ef- ficiency of the international monitoring network planned in the frame of the Com- prehensive Test Ban Treaty. We propose a new approach of backtracking based upon the use of retroplumes associated to available measurements. Firstly the retroplume is related to inverse transport processes, describing quantitatively how the air in a sam- ple originates from regions that are all the more extended and diffuse as we go back far in the past. Secondly it clarifies the sensibility of the measurement with respect to all potential sources. It is therefore calculated by adjoint equations including of course diffusive processes. Thirdly, the statistical interpretation, valid as far as sin- gle particles are concerned, should not be used to investigate the position and date of a macroscopic source. In that case, the retroplume rather induces a straightforward constraint between the intensity of the source and its position. When more than one measurements are available, including zero valued measurements, the source satisfies the same number of linear relations tightly related to the retroplumes. This system of linear relations can be handled through the simplex algorithm in order to make the above intensity-position correlation more restrictive. This method enables to manage in a quantitative manner the

  8. Attribution of the Main Sources of Biomass Burning in South East Asia that Impact on Air Quality in Singapore

    Hansen, A. B.; Kendall, E.; Chew, B. N.; Chong, W. M.; Gan, C.; Hort, M. C.; Shaw, F.; Witham, C. S.

    2017-12-01

    Biomass burning in South East Asia causes intense haze episodes in Singapore, these are of major concern to the local government and the population exposed to the haze. Using a Lagrangian dispersion model we have studied haze in the seven most recent years (2010 - 2016) to gain a deeper understanding of intense haze in Singapore. In this study, modelled haze time-series at one eastern and one western monitoring station in Singapore are compared to local observed PM10 and PM2.5 air concentrations. The haze time-series are broken down by season or month, source region, and monitoring location.The analysis, presented as time series and pie charts, illustrates the relative contribution to haze in Singapore from different regions, variations between seasons and the correlation of impact to the combined timing of burning activity and meteorological patterns. Air history maps, showing where air arriving in Singapore originates from and/or has travelled through, are used to isolate the meteorological dependence of impacts. These show a strong monsoonal variation and help explain the inter-annual differences between sources and actual concentrations of biomass burning PM in Singapore. For example, there is a strong correlation in 2013 between burning in Riau and haze in Singapore, but a weak correlation in other years when a significant part of haze originates from, e.g., Peninsula Malaysia, but emissions are seemingly negligible. We see that, in spite of the size of Singapore, there is significant difference in concentrations and major contributing source regions between the two monitoring stations, annually and seasonally. The differences at the two monitoring stations are seen in varying degrees in the years 2011, 2012, 2014, and 2015, throughout different seasons. Although only biomass burning is considered in the simulations, our modelled results are in good agreement with local observations. We have identified the source regions with the biggest contributions to haze

  9. Allocation and source attribution of lead and cadmium in maize (Zea mays L.) impacted by smelting emissions

    Bi Xiangyang; Feng Xinbin; Yang Yuangen; Li Xiangdong; Shin, Grace P.Y.; Li Feili; Qiu Guangle; Li Guanghui; Liu Taoze; Fu Zhiyou

    2009-01-01

    Plants grown in contaminated areas may accumulate trace metals to a toxic level via their roots and/or leaves. In the present study, we investigated the distribution and sources of Pb and Cd in maize plants (Zea mays L.) grown in a typical zinc smelting impacted area of southwestern China. Results showed that the smelting activities caused significantly elevated concentrations of Pb and Cd in the surrounding soils and maize plants. Pb isotope data revealed that the foliar uptake of atmospheric Pb was the dominant pathway for Pb to the leaf and grain tissues of maize, while Pb in the stalk and root tissues was mainly derived from root uptake. The ratio of Pb to Cd concentrations in the plants indicated that Cd had a different behavior from Pb, with most Cd in the maize plants coming from the soil via root uptake. - The sources and pathways of Pb and Cd accumulated in maize were assessed using Pb isotopes and Pb/Cd ratios

  10. Directional passive ambient air monitoring of ammonia for fugitive source attribution; a field trial with wind tunnel characteristics

    Solera García, M. A.; Timmis, R. J.; Van Dijk, N.; Whyatt, J. D.; Leith, I. D.; Leeson, S. R.; Braban, C. F.; Sheppard, L. J.; Sutton, M. A.; Tang, Y. S.

    2017-10-01

    Atmospheric ammonia is a precursor for secondary particulate matter formation, which harms human health and contributes to acidification and eutrophication. Under the 2012 Gothenburg Protocol, 2005 emissions must be cut by 6% by 2020. In the UK, 83% of total emissions originate from agricultural practices such as fertilizer use and rearing of livestock, with emissions that are spatially extensive and variable in nature. Such fugitive emissions make resolving and tracking of individual site performance challenging. The Directional Passive Air quality Sampler (DPAS) was trialled at Whim Bog, an experimental site with a wind-controlled artificial release of ammonia, in combination with CEH-developed ammonia samplers. Whilst saturation issues were identified, two DPAS-MANDE (Mini Annular Denuder) systems, when deployed in parallel, displayed an average relative deviation of 15% (2-54%) across all 12 directions, with the directions exposed to the ammonia source showing ∼5% difference. The DPAS-MANDE has shown great potential for directional discrimination and can contribute to the understanding and management of fugitive ammonia sources from intensive agriculture sites.

  11. Allocation and source attribution of lead and cadmium in maize (Zea mays L.) impacted by smelting emissions

    Bi Xiangyang [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China); Key Laboratory of Biogeology and Environmental Geology, Ministry of Education, China University of Geosciences, Wuhan 430074 (China); Feng Xinbin [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China)], E-mail: fengxinbin@vip.skleg.cn; Yang Yuangen [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China); Li Xiangdong; Shin, Grace P.Y. [Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong); Li Feili [College of Biological and Environmental Engineering, Zhejiang University of Technology, Hangzhou 310032 (China); Qiu Guangle; Li Guanghui; Liu Taoze; Fu Zhiyou [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China)

    2009-03-15

    Plants grown in contaminated areas may accumulate trace metals to a toxic level via their roots and/or leaves. In the present study, we investigated the distribution and sources of Pb and Cd in maize plants (Zea mays L.) grown in a typical zinc smelting impacted area of southwestern China. Results showed that the smelting activities caused significantly elevated concentrations of Pb and Cd in the surrounding soils and maize plants. Pb isotope data revealed that the foliar uptake of atmospheric Pb was the dominant pathway for Pb to the leaf and grain tissues of maize, while Pb in the stalk and root tissues was mainly derived from root uptake. The ratio of Pb to Cd concentrations in the plants indicated that Cd had a different behavior from Pb, with most Cd in the maize plants coming from the soil via root uptake. - The sources and pathways of Pb and Cd accumulated in maize were assessed using Pb isotopes and Pb/Cd ratios.

  12. Evaluation of Personal and Built Environment Attributes to Physical Activity: A Multilevel Analysis on Multiple Population-Based Data Sources

    Wei Yang

    2012-01-01

    Full Text Available Background. Studies have documented that built environment factors potentially promote or impede leisure time physical activity (LTPA. This study explored the relationship between multiple built environment factors and individual characteristics on LTPA. Methods. Multiple data sources were utilized including individual level data for health behaviors and health status from the Nevada Behavioral Risk Factor Surveillance System (BRFSS and community level data from different data sources including indicators for recreation facilities, safety, air quality, commute time, urbanization, population density, and land mix level. Mixed model logistic regression and geographic information system (GIS spatial analysis were conducted. Results. Among 6,311 respondents, 24.4% reported no LTPA engagement during the past 30 days. No engagement in LTPA was significantly associated with (1 individual factors: older age, less education, lower income, being obesity, and low life satisfaction and (2 community factors: more commute time, higher crime rate, urban residence, higher population density, but not for density and distance to recreation facilities, air quality, and land mix. Conclusions. Multiple data systems including complex population survey and spatial analysis are valuable tools on health and built environment studies.

  13. Development of negative heavy ion sources for plasma potential measurement

    Sasao, M.; Okabe, Y.; Fujisawa, A.; Iguchi, H.; Fujita, J.; Yamaoka, H.; Wada, M.

    1991-10-01

    A plasma sputter negative ion source was studied for its applicability to the potential measurement of a fusion plasma. Both the beam current density and the beam energy spread are key issues. Energy spectra of a self extracted Au - beam from the source were measured under the condition of a constant work function of the production surface. The full width of half maximum (FWHM) increases from 3 eV to 9 eV monotonically as the target voltage increases from 50 V to 300 V, independently from the target surface work function of 2.2 - 3 eV. (author)

  14. Bread fortified with anthocyanin-rich extract from black rice as nutraceutical sources: Its quality attributes and in vitro digestibility.

    Sui, Xiaonan; Zhang, Yan; Zhou, Weibiao

    2016-04-01

    Anthocyanin-rich black rice extract powder (ABREP) as a nutraceutical source was fortified into bread. The quality and digestibility behaviors of bread with ABREP were evaluated through instrumental and in vitro digestion studies. The quality of bread with 2% of ABREP was not significantly (p>0.05) different from the control bread; however, increasing the ABREP level to 4% caused less elasticity and higher density of bread. A mathematical model was further developed to systemically describe the trajectory of bread digestion. The digestion rates of bread with ABREP were found to be reduced by 12.8%, 14.1%, and 20.5% for bread with 1%, 2%, and 4% of ABREP, respectively. Results of the study suggest that the fortification of anthocyanins into bread could be an alternative way to produce functional bread with a lower digestion rate and extra health benefits. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Measuring device for strong gamma-ray sources; Dispositif de mesure des fortes sources emettrices {gamma}

    Engelman, J; Vagner, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    We are given the description of a hollow argon-filled cylindrical ionisation chamber which is to be used to measure gamma-emitting sources. The instrument is currently used at the Measures Department in routine gauging of some radioelements. Sources are introduced into the central part of the chamber through a remote handling device. Measures are directly registered, it is not worth while removing the source from the container; a deviation of the source has little effect on the ionization current. The chamber was gauged to test such elements as: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. Its measuring power approximately ranges from 100 micro-curies to 5 curies. (author) [French] On decrit une chambre d'ionisation cylindrique creuse, a remplissage d'argon, destinee a la mesure des sources emettrices {gamma}. Cet appareil est utilise couramment par la Section Mesures pour l'etalonnage de routine d'un certain nombre de radioelements. Les sources sont mises en place au centre de la chambre par un dispositif de manipulation a distance. La mesure est faite directement, sans qu'il soit necessaire d'extraire la source de son container; un decentrement de la source n'a en effet pas d'influence sensible sur le courant d'ionisation. Cette chambre d'ionisation a ete etalonnee pour divers radioelements: {sup 198}Au, {sup 60}Co, {sup 192}Ir, {sup 24}Na, {sup 137}Cs. La flamme d'activite mesurable s'etend de 100 microcuries a 5 curies, environ. (auteur)

  16. Campylobacteriosis in urban versus rural areas: a case-case study integrated with molecular typing to validate risk factors and to attribute sources of infection.

    Simon Lévesque

    Full Text Available Campylobacter infection is a leading cause of bacterial gastroenteritis worldwide, and most clinical cases appear as isolated, sporadic infections for which the source is rarely apparent. From July 2005 to December 2007 we conducted a prospective case-case study of sporadic, domestically-acquired Campylobacter enteritis in rural versus urban areas and a prevalence study of Campylobacter in animal and environmental sources in the Eastern Townships, Quebec. Isolates were typed using Multilocus Sequence Typing (MLST to reinforce the case-case findings and to assign a source probability estimate for each human isolate. The risk of human campylobacteriosis was 1.89-fold higher in rural than urban areas. Unconditional multivariate logistic regression analysis identified two independent risk factors associated with human Campylobacter infections acquired in rural area: occupational exposure to animals (OR = 10.6, 95% CI: 1.2-91, p = 0.032, and household water coming from a private well (OR = 8.3, 95% CI: 3.4-20.4, p<0.0001. A total of 851 C. jejuni isolates (178 human, 257 chicken, 87 bovine, 266 water, 63 wild bird were typed using MLST. Among human isolates, the incidence rates of clonal complexes (CC CC-21, CC-45, and CC-61 were higher in rural than urban areas. MLST-based source attribution analysis indicated that 64.5% of human C. jejuni isolates were attributable to chicken, followed by cattle (25.8%, water (7.4%, and wild birds (2.3%. Chicken was the attributable source for the majority of cases, independent of residential area, sex and age. The increased incidence in rural compared to urban areas was associated with occupational exposure to animals, particularly cattle among those aged 15-34 years, and with consumption of private well water. Both bovine and water exposure appeared to contribute to the seasonal variation in campylobacteriosis. These results provide a basis for developing public education and preventive programs targeting the

  17. Measurement of radiation skyshine with D-T neutron source

    Yoshida, S.; Nishitani, T. E-mail: nisitani@naka.jaeri.go.jp; Ochiai, K.; Kaneko, J.; Hori, J.; Sato, S.; Yamauchi, M.; Tanaka, R.; Nakao, M.; Wada, M.; Wakisaka, M.; Murata, I.; Kutsukake, C.; Tanaka, S.; Sawamura, T.; Takahashi, A

    2003-09-01

    The D-T neutron skyshine experiments have been carried out at the Fusion Neutronics Source (FNS) of JAERI with the neutron yield of {approx}1.7x10{sup 11} n/s. The concrete thickness of the roof and the wall of a FNS target room are 1.15 and 2 m, respectively. The FNS skyshine port with a size of 0.9x0.9 m{sup 2} was open during the experimental period. The radiation dose rate outside the target room was measured a maximum distance of 550 m from the D-T target point with a spherical rem-counter. Secondary gamma-rays were measured with high purity Ge detectors and NaI scintillation counters. The highest neutron dose was about 9x10{sup -22} Sv/(source neutron) at a distance of 30 m from the D-T target point and the dose rate was attenuated to 4x10{sup -24} Sv/(source neutron) at a distance of 550 m. The measured neutron dose distribution was analyzed with Monte Carlo code MCNP-4B and a simple line source model. The MCNP calculation overestimates the neutron dose in the distance range larger than 230 m. The line source model agrees well with the experimental results within the distance of 350 m.

  18. Absorptivity Measurements and Heat Source Modeling to Simulate Laser Cladding

    Wirth, Florian; Eisenbarth, Daniel; Wegener, Konrad

    The laser cladding process gains importance, as it does not only allow the application of surface coatings, but also additive manufacturing of three-dimensional parts. In both cases, process simulation can contribute to process optimization. Heat source modeling is one of the main issues for an accurate model and simulation of the laser cladding process. While the laser beam intensity distribution is readily known, the other two main effects on the process' heat input are non-trivial. Namely the measurement of the absorptivity of the applied materials as well as the powder attenuation. Therefore, calorimetry measurements were carried out. The measurement method and the measurement results for laser cladding of Stellite 6 on structural steel S 235 and for the processing of Inconel 625 are presented both using a CO2 laser as well as a high power diode laser (HPDL). Additionally, a heat source model is deduced.

  19. Radioactivity measurements of metallic 192Ir sources by calorimetric methods

    Genka, Tsuguo; Iwamoto, Seikichi; Takeuchi, Norio

    1992-01-01

    The necessity of establishing the traceability of dose measurement in brachytherapy 192 Ir sources is realized by physicians and researchers in the medical field. Standard sources of various shapes such as open-quotes hairpin,close quotes open-quotes single pin,close quotes open-quotes thin wire,close quotes and open-quotes seedclose quotes for calibrating ionization chambers in hospitals are being demanded. Nominal activities of not only these source products but also the standard sources have been so far specified by open-quotes apparentclose quotes values. Determination of open-quotes absoluteclose quotes activity by an established means such as 4pi-beta-gamma coincidence counting is not practical because quantitative dissolution of metallic iridium is very difficult. We tried to determine the open-quotes absoluteclose quotes activity by a calorimetric method in a fully nondestructive way

  20. Measurement-device-independent quantum communication with an untrusted source

    Xu, Feihu

    2015-07-01

    Measurement-device-independent quantum key distribution (MDI-QKD) can provide enhanced security compared to traditional QKD, and it constitutes an important framework for a quantum network with an untrusted network server. Still, a key assumption in MDI-QKD is that the sources are trusted. We propose here a MDI quantum network with a single untrusted source. We have derived a complete proof of the unconditional security of MDI-QKD with an untrusted source. Using simulations, we have considered various real-life imperfections in its implementation, and the simulation results show that MDI-QKD with an untrusted source provides a key generation rate that is close to the rate of initial MDI-QKD in the asymptotic setting. Our work proves the feasibility of the realization of a quantum network. The network users need only low-cost modulation devices, and they can share both an expensive detector and a complicated laser provided by an untrusted network server.

  1. Measurement and correction of chromaticity in Hefei light source

    Sun Baogen; Xu Hongliang; He Duohui; Wang Junhua; Lu Ping

    2001-01-01

    The measurement and correction of chromaticity for Hefei light source is introduced. The natural chromaticity is obtained by detecting the variation of the betatron tune with the main dipole field strength. The correction chromaticity is obtained by detecting the variation of the betatron tune with the RF frequency. The theoretic analysis and formula for the two methods is given. The measurement results of chromaticity are given

  2. Do energy efficiency measures promote the use of renewable sources?

    Marques, Antonio C.; Fuinhas, Jose A.

    2011-01-01

    This paper analyses the factors behind the deployment of renewable energy, focusing particularly on the effect of energy efficiency policies and measures. The impact of these factors is appraised within the context of several phases of the use of renewable sources. We therefore apply the quantile regression technique to a set of 21 European Countries in two time spans: from 1990 to 1998, and from 1999 to 2006. We control variables of policy, environment, socioeconomic characteristics, and electricity generation. For the second period, energy efficiency policies and measures concerning renewable sources effectively promote renewables, namely in the take-off phase. We shed light on the lobbying effect of traditional energy industries, showing that it depends both on the period under analysis, and on the kind of traditional energy source.

  3. Spectroscopic measurements of an H- ion source discharge

    Keller, R.; Smith, H.V. Jr.

    1985-01-01

    Spectral emission lines from an H - Penning surface-plasma source (SPS), the 4X source, are examined in the visible and near ultraviolet. Electron distribution temperatures are deduced from integral line-strength measurements. These temperatures are surprisingly low, about 0.5 eV. Electron density values of about 1.5 x 10 14 cm -3 and H-atom energies between 2 and 2.6 eV are determined from the measured Balmer-line profiles. Assuming the H - energy is identical to the H-atom energy, an emittance limit of 0.006 π x cm x mrad is deduced for this source with a 5.4-mm aperture

  4. Miniature electron bombardment evaporation source: evaporation rate measurement

    Nehasil, V.; Masek, K.; Matolin, V.; Moreau, O.

    1997-01-01

    Miniature electron beam evaporation sources which operate on the principle of vaporization of source material, in the form of a tip, by electron bombardment are produced by several companies specialized in UHV equipment. These sources are used primarily for materials that are normally difficult to deposit due to their high evaporation temperature. They are appropriate for special applications such as heteroepitaxial thin film growth requiring a very low and well controlled deposition rate. A simple and easily applicable method of evaporation rate control is proposed. The method is based on the measurement of ion current produced by electron bombardment of evaporated atoms. The absolute evaporation flux values were measured by means of the Bayard-Alpert ion gauge, which enabled the ion current vs evaporation flux calibration curves to be plotted. (author). 1 tab., 4 figs., 6 refs

  5. Security measures in transport of radiation source in Jordan

    Mohammad, Alslman [Korea Advanced Institute of Science and Technology, Kaist Daejeon (Korea, Republic of); Choi, Kwang Sik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-05-15

    Radioactive materials are used in Jordan for peaceful applications in medicine, industry, agriculture, environmental science, education and research and military applications. Most of these radioactive sources used are imported, therefore trans-boundary movement is a significant factor in consideration of security measures during movement of these sources. After 11/9 2001 event, IAEA efforts began to focus and concentrate on security in transport of radioactive materials, after the emergence of risks of using these sources in terrorist activities. In 2002, Efforts were initiated by the IAEA to provide additional guidance for security in the transport of radioactive materials, based upon the new security requirements in the Recommendations on the Transport of Dangerous Goods. This paper reviews some of the measures relating to the transport of radioactive materials in Jordan

  6. Attributing illness to food

    Batz, M. B.; Doyle, M. P.; Morris, J. G.

    2005-01-01

    source responsible for illness. A wide variety of food attribution approaches and data are used around the world including the analysis of outbreak data, case-control studies, microbial subtyping and source tracking methods, and expert judgment, among others. The Food Safety Research Consortium sponsored......Identification and prioritization of effective food safety interventions require an understanding of the relationship between food and pathogen from farm to consumption. Critical to this cause is food attribution, the capacity to attribute cases of foodborne disease to the food vehicle or other...... the Food Attribution Data Workshop in October 2003 to discuss the virtues and limitations of these approaches and to identify future options for collecting food attribution data in the United States. We summarize workshop discussions and identify challenges that affect progress in this critical component...

  7. Effects of neutron source type on soil moisture measurement

    Irving Goldberg; Norman A. MacGillivray; Robert R. Ziemer

    1967-01-01

    A number of radioisotopes have recently become commercially available as alternatives to radium-225 in moisture gauging devices using alpha-neutron sources for determining soil moisture, for well logging, and for other industrial applications in which hydrogenous materials are measured.

  8. Source apportionment of hydrocarbons measured in the Eagle Ford shale

    Roest, G. S.; Schade, G. W.

    2016-12-01

    The rapid development of unconventional oil and gas in the US has led to hydrocarbon emissions that are yet to be accurately quantified. Emissions from the Eagle Ford Shale in southern Texas, one of the most productive shale plays in the U.S., have received little attention due to a sparse air quality monitoring network, thereby limiting studies of air quality within the region. We use hourly atmospheric hydrocarbon and meteorological data from three locations in the Eagle Ford Shale to assess their sources. Data are available from the Texas commission of environmental quality (TCEQ) air quality monitors in Floresville, a small town southeast of San Antonio and just north of the shale area; and Karnes city, a midsize rural city in the center of the shale. Our own measurements were carried out at a private ranch in rural Dimmit County in southern Texas from April to November of 2015. Air quality monitor data from the TCEQ were selected for the same time period. Non-negative matrix factorization in R (package NMF) was used to determine likely sources and their contributions above background. While the TCEQ monitor data consisted mostly of hydrocarbons, our own data include both CO, CO2, O3, and NOx. We find that rural Dimmit County hydrocarbons are dominated by oil and gas development sources, while central shale hydrocarbons at the TCEQ monitoring sites have a mix of sources including car traffic. However, oil and gas sources also dominate hydrocarbons at Floresville and Karnes City. Toxic benzene is nearly exclusively due to oil and gas development sources, including flaring, which NMF identifies as a major hydrocarbon source in Karnes City. Other major sources include emissions of light weight alkanes (C2-C5) from raw natural gas emissions and a larger set of alkanes (C2-C10) from oil sources, including liquid storage tanks.

  9. Exploration of the formation mechanism and source attribution of ambient ozone in Chongqing with an observation-based model

    SU Rong; ZHAI ChongZhi; ZHANG YuanHang; LU KeDing; YU JiaYan; TAN ZhaoFeng; JIANG MeiQing; LI Jing; XIE ShaoDong; WU YuSheng; ZENG LiMin

    2018-01-01

    An intensive field campaign was conducted in Chongqing during the summer of 2015 to explore the formation mechanisms of ozone pollution.The sources of ozone,the local production rates,and the controlling factors,as well as key species of volatile organic compounds (VOCs),were quantified by integrating a local ozone budget analysis,calculations of the relative incremental reactivity,and an empirical kinetic model approach.It was found that the potential for rapid local ozone formation exists in Chongqing.During ozone pollution episodes,the ozone production rates were found to be high at the upwind station Nan Quan,the urban station Chao Zhan,and the downwind station Jin-Yun Shan.The average local ozone production rate was 30× 10-9 V/V h1 and the daily integration of the produced ozone was greater than 180× 10-9 V/V.High ozone concentrations were associated with urban and downwind air masses.At most sites,the local ozone production was VOC-limited and the key species were aromatics and alkene,which originated mainly from vehicles and solvent usage.In addition,the air masses at the northwestern rural sites were NOx-limited and the local ozone production rates were significantly higher during the pollution episodes due to the increased NOx concentrations.In summary,the ozone abatement strategies of Chongqing should be focused on the mitigation of VOCs.Nevertheless,a reduction in NOx is also beneficial for reducing the regional ozone peak values in Chongqing and the surrounding areas.

  10. Gluon attributes

    Weiler, T.

    1981-01-01

    An overview is presented of the attributes of gluons, deducible from experimental data. Particular attention is given to the photon-gluon fusion model of charm leptoproduction. The agreement with QCD and theoretical prejudice is qualitatively good

  11. Bayesian source term determination with unknown covariance of measurements

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  12. Dynamic Aperture Measurements at the Advanced Light Source

    Decking, W.; Robin, D.

    1999-01-01

    A large dynamic aperture for a storage ring is of importance for long lifetimes and a high injection efficiency. Measurements of the dynamic aperture of the third generation synchrotron light source Advanced Light Source (ALS) using beam excitation with kicker magnets are presented. The experiments were done for various accelerator conditions, allowing us to investigate the influence of different working points, chromaticities, insertion devices, etc.. The results are compared both with tracking calculations and a simple model for the dynamic aperture yielding good agreements. This gives us confidence in the predictability of the nonlinear accelerator model. This is especially important for future ALS upgrades as well as new storage ring designs

  13. Study of localized photon source in space of measures

    Lisi, M.

    2010-01-01

    In this paper we study a three-dimensional photon transport problem in an interstellar cloud, with a localized photon source inside. The problem is solved indirectly, by defining the adjoint of an operator acting on an appropriate space of continuous functions. By means of sun-adjoint semi groups theory of operators in a Banach space of regular Borel measures, we prove existence and uniqueness of the solution of the problem. A possible approach to identify the localization of the photon source is finally proposed.

  14. The error sources appearing for the gamma radioactive source measurement in dynamic condition

    Sirbu, M.

    1977-01-01

    The error analysis for the measurement of the gamma radioactive sources, placed on the soil, with the help of the helicopter are presented. The analysis is based on a new formula that takes account of the attenuation gamma ray factor in the helicopter walls. They give a complete error formula and an error diagram. (author)

  15. Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements.

    Malin, Martha J; Palmer, Benjamin R; DeWerd, Larry A

    2016-02-01

    Energy-based source strength metrics may find use with model-based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low-dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low-dose rate, photon-emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work. A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four (125)I sources with air-kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39-0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air-kerma strengths to EPs through Monte Carlo-derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique. The calorimeter had a noise floor of 1-3 nW and a repeatability of 30-60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level. A calorimeter capable of measuring the EP from LDR sources has been developed and validated for (125)I sources with EPs between 0.43 and 0.79 μW.

  16. Eddy covariance methane flux measurements over a grazed pasture: effect of cows as moving point sources

    Felber, R.; Münger, A.; Neftel, A.; Ammann, C.

    2015-06-01

    Methane (CH4) from ruminants contributes one-third of global agricultural greenhouse gas emissions. Eddy covariance (EC) technique has been extensively used at various flux sites to investigate carbon dioxide exchange of ecosystems. Since the development of fast CH4 analyzers, the instrumentation at many flux sites has been amended for these gases. However, the application of EC over pastures is challenging due to the spatially and temporally uneven distribution of CH4 point sources induced by the grazing animals. We applied EC measurements during one grazing season over a pasture with 20 dairy cows (mean milk yield: 22.7 kg d-1) managed in a rotational grazing system. Individual cow positions were recorded by GPS trackers to attribute fluxes to animal emissions using a footprint model. Methane fluxes with cows in the footprint were up to 2 orders of magnitude higher than ecosystem fluxes without cows. Mean cow emissions of 423 ± 24 g CH4 head-1 d-1 (best estimate from this study) correspond well to animal respiration chamber measurements reported in the literature. However, a systematic effect of the distance between source and EC tower on cow emissions was found, which is attributed to the analytical footprint model used. We show that the EC method allows one to determine CH4 emissions of cows on a pasture if the data evaluation is adjusted for this purpose and if some cow distribution information is available.

  17. Lunar occultations for gamma-ray source measurements

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  18. Estimating source-attributable health impacts of ambient fine particulate matter exposure: global premature mortality from surface transportation emissions in 2005

    Chambliss, S E; Zeinali, M; Minjares, R; Silva, R; West, J J

    2014-01-01

    Exposure to ambient fine particular matter (PM 2.5 ) was responsible for 3.2 million premature deaths in 2010 and is among the top ten leading risk factors for early death. Surface transportation is a significant global source of PM 2.5 emissions and a target for new actions. The objective of this study is to estimate the global and national health burden of ambient PM 2.5 exposure attributable to surface transportation emissions. This share of health burden is called the transportation attributable fraction (TAF), and is assumed equal to the proportional decrease in modeled ambient particulate matter concentrations when surface transportation emissions are removed. National population-weighted TAFs for 190 countries are modeled for 2005 using the MOZART-4 global chemical transport model. Changes in annual average concentration of PM 2.5 at 0.5 × 0.67 degree horizontal resolution are based on a global emissions inventory and removal of all surface transportation emissions. Global population-weighted average TAF was 8.5 percent or 1.75 μg m −3 in 2005. Approximately 242 000 annual premature deaths were attributable to surface transportation emissions, dominated by China, the United States, the European Union and India. This application of TAF allows future Global Burden of Disease studies to estimate the sector-specific burden of ambient PM 2.5 exposure. Additional research is needed to capture intraurban variations in emissions and exposure, and to broaden the range of health effects considered, including the effects of other pollutants. (letter)

  19. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Yang, Yuan-Pei; Zhang, Bing, E-mail: yypspore@gmail.com, E-mail: zhang@physics.unlv.edu [Kavli Institute for Astronomy and Astrophysics, Peking University, Beijing 100871 (China)

    2017-09-20

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  20. Dispersion Measure Variation of Repeating Fast Radio Burst Sources

    Yang, Yuan-Pei; Zhang, Bing

    2017-01-01

    The repeating fast radio burst (FRB) 121102 was recently localized in a dwarf galaxy at a cosmological distance. The dispersion measure (DM) derived for each burst from FRB 121102 so far has not shown significant evolution, even though an apparent increase was recently seen with newly detected VLA bursts. It is expected that more repeating FRB sources may be detected in the future. In this work, we investigate a list of possible astrophysical processes that might cause DM variation of a particular FRB source. The processes include (1) cosmological scale effects such as Hubble expansion and large-scale structure fluctuations; (2) FRB local effects such as gas density fluctuation, expansion of a supernova remnant (SNR), a pulsar wind nebula, and an H ii region; and (3) the propagation effect due to plasma lensing. We find that the DM variations contributed by the large-scale structure are extremely small, and any observable DM variation is likely caused by the plasma local to the FRB source. In addition to mechanisms that decrease DM over time, we suggest that an FRB source in an expanding SNR around a nearly neutral ambient medium during the deceleration (Sedov–Taylor and snowplow) phases or in a growing H ii region can increase DM. Some effects (e.g., an FRB source moving in an H ii region or plasma lensing) can produce either positive or negative DM variations. Future observations of DM variations of FRB 121102 and other repeating FRB sources can provide important clues regarding the physical origin of these sources.

  1. The rotation measures of radio sources and their interpretation

    Vallee, J.P.; Kronberg, P.P.

    1975-01-01

    Rotation measures of 251 discrete radio sources have been determined after incorporating new polarization data at short wavelenghts. These have been applied to a 'slab' model-fitting technique to determine the most likely spiral arm magnetic field structure. The best agreement is obtained for a longitudinal spiral arm magnetic field, directed toward (lII approximately 90 0 , bII approximately 0 0 ), but perturbed by an anomaly towards the North Galactic Spur. (orig.) [de

  2. Bayesian statistics in radionuclide metrology: measurement of a decaying source

    Bochud, F. O.; Bailat, C.J.; Laedermann, J.P.

    2007-01-01

    The most intuitive way of defining a probability is perhaps through the frequency at which it appears when a large number of trials are realized in identical conditions. The probability derived from the obtained histogram characterizes the so-called frequentist or conventional statistical approach. In this sense, probability is defined as a physical property of the observed system. By contrast, in Bayesian statistics, a probability is not a physical property or a directly observable quantity, but a degree of belief or an element of inference. The goal of this paper is to show how Bayesian statistics can be used in radionuclide metrology and what its advantages and disadvantages are compared with conventional statistics. This is performed through the example of an yttrium-90 source typically encountered in environmental surveillance measurement. Because of the very low activity of this kind of source and the small half-life of the radionuclide, this measurement takes several days, during which the source decays significantly. Several methods are proposed to compute simultaneously the number of unstable nuclei at a given reference time, the decay constant and the background. Asymptotically, all approaches give the same result. However, Bayesian statistics produces coherent estimates and confidence intervals in a much smaller number of measurements. Apart from the conceptual understanding of statistics, the main difficulty that could deter radionuclide metrologists from using Bayesian statistics is the complexity of the computation. (authors)

  3. Timing jitter measurements at the SLC electron source

    Sodja, J.; Browne, M.J.; Clendenin, J.E.

    1989-03-01

    The SLC thermionic gun and electron source produce a beam of up to 15 /times/ 10 10 /sub e//minus/ in a single S-band bunch. A 170 keV, 2 ns FWHM pulse out of the gun is compressed by means of two subharmonic buncher cavities followed by an S-band buncher and a standard SLAC accelerating section. Ceramic gaps in the beam pipe at the output of the gun allow a measure of the beam intensity and timing. A measurement at these gaps of the timing jitter, with a resolution of <10 ps, is described. 3 refs., 5 figs

  4. A gamma-source method of measuring soil moisture

    Al-Jeboori, M.A.; Ameen, I.A.

    1986-01-01

    Water content in soil column was measured using NaI scintillation detector 5 mci Cs-137 as a gamma source. The measurements were done with a back scatter gauge, restricted with scattering angle less to than /2 overcome the effect of soil type. A 3 cm air gap was maintained between the front of the detector and the wall of the soil container in order to increase the counting rate. The distance between the center of the source and the center of the back scattering detector was 14 cm. The accuracy of the measurements was 0.63. For comparision, a direct rays method was used to measure the soil moisture. The results gave an error of 0.65. Results of the two methods were compared with the gravimetric method which gave an error of 0.18 g/g and 0.17 g/g for direct and back method respectively. The quick direct method was used to determine the gravimetric and volumetric percentage constants, and were found to be 1.62 and 0.865 respectively. The method then used to measure the water content in the layers of soil column.(6 tabs., 4 figs., 12 refs.)

  5. Team composition and chronic disease management within primary healthcare practices in eastern Ontario: an application of the Measuring Organizational Attributes of Primary Health Care Survey.

    Lukewich, Julia; Edge, Dana S; VanDenKerkhof, Elizabeth; Williamson, Tyler; Tranmer, Joan

    2018-04-15

    Various organizational-level attributes are being implemented in primary healthcare to improve healthcare delivery. There is a need to describe the distribution and nature of these attributes and explore differences across practices.AimThe aim of this study was to better understand organizational attributes of primary care teams, focusing specifically on team composition, nursing roles, and strategies that support chronic disease management. We employed a cross-sectional survey design. Team composition, nursing roles, availability of health services, and chronic disease management activities were described using the 'Measuring Organizational Attributes of Primary Health Care Survey.'FindingsA total of 76% (n=26 out of 34) of practice locations completed the survey, including family health teams (FHT; n=21) and community health centers (CHC; n=4). Nurse practitioners (NPs) and registered nurses (RNs) were the most common non-physician providers, and CHCs had a greater proportion of non-physician providers than FHTs. There was overlap in roles performed by NPs and RNs, and registered practical nurses engaged in fewer roles compared with NPs and RNs. A greater proportion of FHTs had systematic chronic disease management services for hypertension, depression and Alzheimer's disease compared with CHC practices. The 'Measuring Organizational Attributes of Primary Health Care Survey' was a useful tool to highlight variability in organizational attributes across PHC practices. Nurses are prominent within PHC practices, engaging in a wide range of roles related to chronic disease management, suggesting a need to better understand their contributions to patient care to optimize their roles.

  6. Effect of dietary incorporation of n-3 polyunsaturated fatty acids rich oil sources on fatty acid profile, keeping quality and sensory attributes of broiler chicken meat

    Sridhar Kalakuntla

    2017-12-01

    Full Text Available The present study was undertaken to investigate the effect of dietary replacement of commonly used vegetable oil (sunflower oil, SFO with n-3 polyunsaturated fatty acids (PUFA rich oil sources on broiler chicken performance, carcass yield, meat fatty acid composition, keeping quality and sensory attributes of meat. In the current experiment, 300 day-old Krishibro broiler chicks were randomly distributed to 5 dietary groups (50 replicates with 6 chicks in each prepared by replacing SFO (2% and 3% of diet during starter and finisher periods, respectively with n-3 PUFA rich soybean oil (SO, mustard oil (MO, linseed oil (LO or fish oil (FO on weight basis. Variation in oil sources had no influence (P > 0.05 on performance and carcass yield. Supplementation of MO, LO or FO significantly (P < 0.01 increased the n-3 PUFA, lowered the n-6 PUFA deposition and n-6:n-3 ratio in breast and thigh without affecting the organoleptic characters (appearance, flavour, juiciness, tenderness and overall acceptability of meat. However, thiobarbituric acid reacting substances concentration in meat was increased (P < 0.01 with LO and FO supplementation compared with SFO. It is concluded that, dietary incorporation of MO, LO or FO at 2% and 3% levels during starter and finisher phase can enrich broiler chicken meat with n-3 PUFA without affecting the bird's performance and sensory characters of meat.

  7. Application of trajectory clustering and source attribution methods for investigating regional CO2 and CH4 concentrations at Germany's highest mountain site

    Giemsa, Esther; Jacobeit, Jucundus; Ries, Ludwig; Frank, Gabriele; Hachinger, Stephan; Meyer-Arnek, Julian

    2017-04-01

    Carbon dioxide (CO2) and methane (CH4) represent the most important contributors to increased radiative forcing enhancing it together by contemporary 2.65 W/m2 on the global average (IPCC 2013). The unbroken increase of atmospheric greenhouse gases (GHG) has been unequivocally attributed to human emissions mainly coming from fossil fuel burning and land-use changes, while the oceans and terrestrial ecosystems slightly attenuate this rise with seasonally varying strength. Short-term fluctuations in the GHG concentrations that superimpose the seasonal cycle and the climate change driven trend reflect the presence of regional sources and sinks. A perfect place for investigating the comprehensive influence of these regional emissions is provided by the Environmental Research Station Schneefernerhaus (47.42°N, 10.98°E, 2.650m a.s.l.) situated in the eastern Alps at the southern side of Zugspitze mountain. Located just 300m below the highest peak of the German Alps, the exposed site is one of the currently 30 global core sites of the World Meteorological Organisation (WMO) Global Atmosphere Watch (GAW) programme and thus provides ideal conditions to study source-receptor relationships for greenhouse gases. We propose a stepwise statistical methodology for examining the relationship between synoptic-scale atmospheric transport patterns and climate gas mole fractions to finally receive a characterization of the sampling site with regard to the key processes driving CO2 and CH4 concentration levels. The first step entails a reliable radon-based filtering approach to subdivide the detected air masses according to their regional or 'background' origin. Simultaneously, a large number of ten-day back-trajectories from Schneefernerhaus every two hours over the entire study period 2011 - 2015 is calculated with the Lagrangian transport and dispersion model FLEXPART (Stohl et al. 2005) and subjected to cluster analysis. The weather- and emission strength-related (short

  8. Electromagnetic-coil (EM-coil) measurement technique to verify presence of metal/absence of oxide attribute

    Fuller, J.L.; Hockey, R.L.

    2001-01-01

    This paper summarizes how an Electromagnetic-coil (EM-coil) measurement technique can be used to discriminate between plutonium metal and plutonium oxide inside sealed storage containers. As evidence, measurements on a variety of metals and their oxides are presented. This non-radiation measurement method provides assurance of the 'presence of metal/absence of oxide' attribute in less than a minute. During initial development, researchers at Pacific Northwest Laboratory have demonstrated the ability of this method to discriminate between aluminum and aluminum oxide placed inside an AT-400R storage container (total stainless steel wall thickness of over 2.5 cm). Similar results are expected, since Pu metal is electrically conductive and a Pu oxide behaves as an electrical insulator. At this writing, work is underway to perform the same demonstration using plutonium and plutonium oxide. Similar success has been demonstrated when using ALR-8 storage containers (basically carbon steel drums). Within these container types two scenarios have been explored. 1.) The same configuration made from different metals for demonstrating material property effects. A clear distinction was seen between the slight alloy changes among various forms of aluminum and brass in the same configuration. 2.) The same metal configured differently to demonstrate how mass distribution affects the EM signature. Hundreds of bb's (each about 2 mm in diameter) were placed in different containers to show how a slight change in distribution will affect the EM signature. With a five percent change in bb container diameter, the resulting EM signature changes are clear. This measurement method offers an extremely wide dynamic range resulting from its sensitivity to the wide range in electrical conductivity and magnetic permeability found in most metals and alloys. In fact, electrical conductivity spans the widest spectrum of all the known physical properties. Most insulators such as the oxides cover the

  9. Attributing Hacks

    Liu, Ziqi; Smola, Alexander J.; Soska, Kyle; Wang, Yu-Xiang; Zheng, Qinghua; Zhou, Jun

    2016-01-01

    In this paper we describe an algorithm for estimating the provenance of hacks on websites. That is, given properties of sites and the temporal occurrence of attacks, we are able to attribute individual attacks to joint causes and vulnerabilities, as well as estimating the evolution of these vulnerabilities over time. Specifically, we use hazard regression with a time-varying additive hazard function parameterized in a generalized linear form. The activation coefficients on each feature are co...

  10. Geometric buckling measurements using the pulsed neutron source method

    Sjoestrand, N G; Mednis, J; Nilsson, T

    1959-03-15

    The geometric buckling of cylindrical reactors with one or both ends rounded has been determined by pulsed source measurements with small polyethylene geometries. The results were in general accord with theoretical calculations. The diffusion parameters of polyethylene were also determined. The diffusion length was 2.12 {+-} 0.03 cm, and for the capture cross section of hydrogen a value of 0.337 {+-} 0.005 barns was found. The effect of control rods was studied using thin cadmium rods in water. Good agreement was found for axial, central rods, whereas the theoretical predictions for the effect of diagonal rods were too high.

  11. Geometric buckling measurements using the pulsed neutron source method

    Sjoestrand, N.G.; Mednis, J.; Nilsson, T.

    1959-03-01

    The geometric buckling of cylindrical reactors with one or both ends rounded has been determined by pulsed source measurements with small polyethylene geometries. The results were in general accord with theoretical calculations. The diffusion parameters of polyethylene were also determined. The diffusion length was 2.12 ± 0.03 cm, and for the capture cross section of hydrogen a value of 0.337 ± 0.005 barns was found. The effect of control rods was studied using thin cadmium rods in water. Good agreement was found for axial, central rods, whereas the theoretical predictions for the effect of diagonal rods were too high

  12. Development of an instrument measuring the perceived attributes of implementing a healthy diet innovation in the Lower Mississippi Delta

    The purpose of this research was to develop a valid and reliable instrument to assess individuals' perceived attributes of implementing a healthy diet. Using the Diffusion of Innovations (DOI) theory as a conceptual framework, this descriptive study consisted of three phases. Phase 1 included group ...

  13. PWFA plasma source - interferometric diagnostics for Li vapor density measurements

    Sivakumaran, V.; Mohandas, K.K.; Singh, Sneha; Ravi Kumar, A.V.

    2015-01-01

    A prototype (40 cm long) plasma source based on Li heat pipe oven has been developed for the Plasma Wakefield Acceleration (PWFA) experiments at IPR (IPR), Gujarat as a part of the ongoing Accelerator Programme. Li vapor in the oven is produced by heating solid Li in helium buffer gas. A uniform column of Li plasma is generated by UV photo ionization (193 nm) of the Li vapor in the heat pipe oven. In these experiments, an accurate measurement of Li vapor density is important as it has got a direct consequence on the plasma electron density. In the present experiment, the vapor density is measured optically by using Hook method (spectrally resolved white light interferometry). The hook like structure formed near the vicinity of the Li 670.8 nm resonance line was recorded with a white light Mach Zehnder interferometer crossed with an imaging spectrograph to estimate the Li vapor density. The vapor density measurements have been carried out as a function of external oven temperature and the He buffer gas pressure. This technique has the advantage of being insensitive to line broadening and line shape, and its high dynamic range even with optically thick absorption line. Here, we present the line integrated Lithium vapor density measurement using Hook method and also compare the same with other optical diagnostic techniques (White light absorption and UV absorption) for Li vapor density measurements. (author)

  14. Gasdynamic measurements for the LASL intense neutron source

    Johnston, S.C.

    1978-02-01

    Measurements made on a two-dimensional simulation of the Los Alamos Scientific Laboratory (LASL) Intense Neutron Source (INS) experiment are discussed. The purpose of this work was to characterize the supersonic INS channel flow under conditions of large amounts of energy deposition. Nozzle channel wall pressure measurements, cold flow leakage rates, vacuum channel pressure and Mach number, leakage flow rates with mass addition to and momentum extraction from the main flow, and flow visualization photographs are given. Energy addition up to thirty percent of the theoretical maximum was achieved via mass addition to and momentum extraction from the main channel flow. In this range, both a weak and strong regime for leakage flow were identified. These regimes differed by about twenty percent in leakage flow rates

  15. Spectroscopic measurements of anode plasma with cryogenic pulsed ion sources

    Yoneda, H.; Urata, T.; Ohbayashi, K.; Kim, Y.; Horioka, K.; Kasuya, K.

    1987-01-01

    In ion beam diodes, electromagnetic wave is coupled to ion beam. Ion is extracted from anode plasma, which is produced early in the power pulse. However, exact mechanism of anode plasma production, expansion and ion extraction process is unknown. In particularly, anode plasma expansion is seemed to be one of the reasons of rapid impedance collapse of the diode, which is serious problem in high power experiments. Some experimental results showed that anode plasma expansion velocity was about 5 times larger than that inferred from simple thermal velocity. Several explanations for these results were proposed; for example, electron collisionarity in anode plasma, fast neutral gas particle, diamagnetism. To solve this question, it is necessary to measure the characteristic of anode plasma with space and time resolution. The authors made spectroscopic measurements to investigate variety of electron temperature, electron density, expansion velocity of anode plasma with various ion sources

  16. The Suicidal Ideation Attributes Scale (SIDAS): Community-Based Validation Study of a New Scale for the Measurement of Suicidal Ideation

    van Spijker, B.A.J.; Batterham, P.J.; Calear, A.L.; Farrer, L.; Christensen, H.; Reynolds, J.; Kerkhof, A.

    2014-01-01

    While suicide prevention efforts are increasingly being delivered using technology, no scales have been developed specifically for web-based use. The Suicidal Ideation Attributes Scale (SIDAS) was developed and validated as a brief, web-based measure for severity of suicidal ideation, using an

  17. Attribution and evolution of ozone from Asian wild fires using satellite and aircraft measurements during the ARCTAS campaign

    R. Dupont

    2012-01-01

    Full Text Available We use ozone and carbon monoxide measurements from the Tropospheric Emission Spectrometer (TES, model estimates of Ozone, CO, and ozone pre-cursors from the Real-time Air Quality Modeling System (RAQMS, and data from the NASA DC8 aircraft to characterize the source and dynamical evolution of ozone and CO in Asian wildfire plumes during the spring ARCTAS campaign 2008. On the 19 April, NASA DC8 O3 and aerosol Differential Absorption Lidar (DIAL observed two biomass burning plumes originating from North-Western Asia (Kazakhstan and South-Eastern Asia (Thailand that advected eastward over the Pacific reaching North America in 10 to 12 days. Using both TES observations and RAQMS chemical analyses, we track the wildfire plumes from their source to the ARCTAS DC8 platform. In addition to photochemical production due to ozone pre-cursors, we find that exchange between the stratosphere and the troposphere is a major factor influencing O3 concentrations for both plumes. For example, the Kazakhstan and Siberian plumes at 55 degrees North is a region of significant springtime stratospheric/tropospheric exchange. Stratospheric air influences the Thailand plume after it is lofted to high altitudes via the Himalayas. Using comparisons of the model to the aircraft and satellite measurements, we estimate that the Kazakhstan plume is responsible for increases of O3 and CO mixing ratios by approximately 6.4 ppbv and 38 ppbv in the lower troposphere (height of 2 to 6 km, and the Thailand plume is responsible for increases of O3 and CO mixing ratios of approximately 11 ppbv and 71 ppbv in the upper troposphere (height of 8 to 12 km respectively. However, there are significant sources of uncertainty in these estimates that point to the need for future improvements in both model and satellite observations. For example, it is challenging to characterize the fraction of air parcels from the stratosphere versus those from the

  18. sources

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  19. Mobile Measurement of Methane and Ethane for the Detection and Attribution of Natural Gas Pipeline Leaks Using Off-Axis Integrated Output Spectroscopy

    Leen, J. B.; Spillane, S.; Gardner, A.; Hansen, P. C.; Gupta, M.; Baer, D. S.

    2015-12-01

    Natural gas leaks pose a risk to public safety both because of potential explosions as well as from the greenhouse gas potential of fugitive methane. The rapid and cost effective detection of leaks in natural gas distribution is critical to providing a system that is safe for the public and the environment. Detection of methane from a mobile platform (vehicles, aircraft, etc.) is an accepted method of identifying leaks. A robust approach to differentiating pipeline gas (thermogenic) from other biogenic sources is the detection of ethane along with methane. Ethane is present in nearly all thermogenic gas but not in biogenic sources and its presence can be used to positively identify a gas sample. We present a mobile system for the simultaneous measurement of methane and ethane that is capable of detecting pipeline leaks and differentiating pipeline gas from other biogenic sources such as landfills, swamps, sewers, and enteric fermentation. The mobile system consists of a high precision GPS, sonic anemometer, and methane/ethane analyzer based on off-axis integrated cavity output spectroscopy (OA-ICOS). In order to minimize the system cost and facilitate the wide use of mobile leak detection, the analyzer operates in the near-infrared portion of the spectrum where lasers and optics are significantly less costly than in the mid-infrared. The analyzer is capable of detecting methane with a precision of detecting ethane with a precision of detection of leaks at speeds up to 50 mph. The sonic anemometer, GPS and analyzer inlet are mounted to a generic roof rack for attachment to available fleet vehicles. The system can detect leaks having a downwind concentration of as little as 10 ppb of methane above ambient, while leaks 500 ppb above ambient can be identified as thermogenic with greater than 99% certainty (for gas with 6% ethane). Finally, analysis of wind data provides an estimate of leak direction and distance. The system presented provides a robust, cost effective

  20. Determining the VLF/ULF source height using phase measurements

    Ryabov, A.; Kotik, D. S.

    2012-12-01

    Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.

  1. Pulsed Source Measurements on a Uranium-Water Subcritical Assembly

    Gibson, I.H.; Walker, J.

    1964-01-01

    An unreflected assembly of natural uranium and light water has been used in conjunction with a pulsed source of neutrons for decay-time measurements at different bucklings. Four different lattice pitches over the range 3.94 cm to 5.08 cm were obtained by using different pairs of accurately machined lattice plates and in each case the uranium was in the form of bars 109.8 cm long and 3.0 cm diameter. The fuel- was mounted horizontally and loadings up to approximately 6 t were involved. Spatial harmonics were eliminated or selected by appropriate placing of a small scintillation detector. Experimental results showing the dependence of decay constant on buckling are presented and compared with theoretical values. (author) [fr

  2. Measuring The Variability Of Gamma-Ray Sources With AGILE

    Chen, Andrew W.; Vercellone, Stefano; Pellizzoni, Alberto; Tavani, Marco

    2005-01-01

    Variability in the gamma-ray flux above 100 MeV at various time scales is one of the primary characteristics of the sources detected by EGRET, both allowing the identification of individual sources and constraining the unidentified source classes. We present a detailed simulation of the capacity of AGILE to characterize the variability of gamma-ray sources, discussing the implications for source population studies

  3. Apportionment of urban aerosol sources in Cork (Ireland) by synergistic measurement techniques.

    Dall'Osto, Manuel; Hellebust, Stig; Healy, Robert M; O'Connor, Ian P; Kourtchev, Ivan; Sodeau, John R; Ovadnevaite, Jurgita; Ceburnis, Darius; O'Dowd, Colin D; Wenger, John C

    2014-09-15

    The sources of ambient fine particulate matter (PM2.5) during wintertime at a background urban location in Cork city (Ireland) have been determined. Aerosol chemical analyses were performed by multiple techniques including on-line high resolution aerosol time-of-flight mass spectrometry (Aerodyne HR-ToF-AMS), on-line single particle aerosol time-of-flight mass spectrometry (TSI ATOFMS), on-line elemental carbon-organic carbon analysis (Sunset_EC-OC), and off-line gas chromatography/mass spectrometry and ion chromatography analysis of filter samples collected at 6-h resolution. Positive matrix factorization (PMF) has been carried out to better elucidate aerosol sources not clearly identified when analyzing results from individual aerosol techniques on their own. Two datasets have been considered: on-line measurements averaged over 2-h periods, and both on-line and off-line measurements averaged over 6-h periods. Five aerosol sources were identified by PMF in both datasets, with excellent agreement between the two solutions: (1) regional domestic solid fuel burning--"DSF_Regional," 24-27%; (2) local urban domestic solid fuel burning--"DSF_Urban," 22-23%; (3) road vehicle emissions--"Traffic," 15-20%; (4) secondary aerosols from regional anthropogenic sources--"SA_Regional" 9-13%; and (5) secondary aged/processed aerosols related to urban anthropogenic sources--"SA_Urban," 21-26%. The results indicate that, despite regulations for restricting the use of smoky fuels, solid fuel burning is the major source (46-50%) of PM2.5 in wintertime in Cork, and also likely other areas of Ireland. Whilst wood combustion is strongly associated with OC and EC, it was found that peat and coal combustion is linked mainly with OC and the aerosol from these latter sources appears to be more volatile than that produced by wood combustion. Ship emissions from the nearby port were found to be mixed with the SA_Regional factor. The PMF analysis allowed us to link the AMS cooking organic

  4. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source.

    Rivard, Mark J; Davis, Stephen D; DeWerd, Larry A; Rusch, Thomas W; Axelrod, Steve

    2006-11-01

    A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, S700 Source exhibited depth dose behavior similar to low-energy photon-emitting low dose rate sources 125I and l03Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages.

  5. 'Manage and mitigate punitive regulatory measures, enhance the corporate image, influence public policy': industry efforts to shape understanding of tobacco-attributable deforestation.

    Lee, Kelley; Carrillo Botero, Natalia; Novotny, Thomas

    2016-09-20

    Deforestation due to tobacco farming began to raise concerns in the mid 1970s. Over the next 40 years, tobacco growing increased significantly and shifted markedly to low- and middle-income countries. The percentage of deforestation caused by tobacco farming reached 4 % globally by the early 2000s, although substantially higher in countries such as China (18 %), Zimbabwe (20 %), Malawi (26 %) and Bangladesh (>30 %). Transnational tobacco companies (TTCs) have argued that tobacco-attributable deforestation is not a serious problem, and that the industry has addressed the issue through corporate social responsibility (CSR) initiatives. After reviewing the existing scholarly literature on tobacco and deforestation, we analysed industry sources of public information to understand how the industry framed deforestation, its key causes, and policy responses. To analyse industry strategies between the 1970s and early 2000s to shape understanding of deforestation caused by tobacco farming and curing, the Truth Tobacco Documents Library was systematically searched. The above sources were compiled and triangulated, thematically and chronologically, to derive a narrative of how the industry has framed the problem of, and solutions to, tobacco-attributable deforestation. The industry sought to undermine responses to tobacco-attributable deforestation by emphasising the economic benefits of production in LMICs, blaming alternative causes, and claiming successful forestation efforts. To support these tactics, the industry lobbied at the national and international levels, commissioned research, and colluded through front groups. There was a lack of effective action to address tobacco-attributable deforestation, and indeed an escalation of the problem, during this period. The findings suggest the need for independent data on the varied environmental impacts of the tobacco industry, awareness of how the industry seeks to work with environmental researchers and groups to

  6. A View on the Importance of "Multi-Attribute Method" for Measuring Purity of Biopharmaceuticals and Improving Overall Control Strategy.

    Rogers, Richard S; Abernathy, Michael; Richardson, Douglas D; Rouse, Jason C; Sperry, Justin B; Swann, Patrick; Wypych, Jette; Yu, Christopher; Zang, Li; Deshpande, Rohini

    2017-11-30

    Today, we are experiencing unprecedented growth and innovation within the pharmaceutical industry. Established protein therapeutic modalities, such as recombinant human proteins, monoclonal antibodies (mAbs), and fusion proteins, are being used to treat previously unmet medical needs. Novel therapies such as bispecific T cell engagers (BiTEs), chimeric antigen T cell receptors (CARTs), siRNA, and gene therapies are paving the path towards increasingly personalized medicine. This advancement of new indications and therapeutic modalities is paralleled by development of new analytical technologies and methods that provide enhanced information content in a more efficient manner. Recently, a liquid chromatography-mass spectrometry (LC-MS) multi-attribute method (MAM) has been developed and designed for improved simultaneous detection, identification, quantitation, and quality control (monitoring) of molecular attributes (Rogers et al. MAbs 7(5):881-90, 2015). Based on peptide mapping principles, this powerful tool represents a true advancement in testing methodology that can be utilized not only during product characterization, formulation development, stability testing, and development of the manufacturing process, but also as a platform quality control method in dispositioning clinical materials for both innovative biotherapeutics and biosimilars.

  7. MEASURING THE SOURCES OF THE INTERGALACTIC IONIZING FLUX

    Cowie, L. L.; Barger, A. J.; Trouille, L.

    2009-01-01

    We use a wide-field (0.9 deg 2 ) X-ray sample with optical and Galaxy Evolution Explorer (GALEX) ultraviolet observations to measure the contribution of active galactic nuclei (AGNs) to the ionizing flux as a function of redshift. Our analysis shows that the AGN contribution to the metagalactic ionizing background peaks at around z = 2. The measured values of the ionizing background from the AGNs are lower than previous estimates and confirm that ionization from AGNs is insufficient to maintain the observed ionization of the intergalactic medium (IGM) at z > 3. We show that only X-ray sources with broad lines in their optical spectra have detectable ionizing flux and that the ionizing flux seen in an AGN is not correlated with its X-ray color. We also use the GALEX observations of the GOODS-N region to place a 2σ upper limit of 0.008 on the average ionization fraction f ν (700 A)/f ν (1500 A) for 626 UV selected galaxies in the redshift range z = 0.9-1.4. We then use this limit to estimate an upper bound to the galaxy contribution in the redshift range z = 0-5. If the z ∼ 1.15 ionization fraction is appropriate for higher-redshift galaxies, then contributions from the galaxy population are also too low to account for the IGM ionization at the highest redshifts (z > 4).

  8. Aerosol source apportionment from 1-year measurements at the CESAR tower in Cabauw, the Netherlands

    P. Schlag

    2016-07-01

    Full Text Available Intensive measurements of submicron aerosol particles and their chemical composition were performed with an Aerosol Chemical Speciation Monitor (ACSM at the Cabauw Experimental Site for Atmospheric Research (CESAR in Cabauw, the Netherlands, sampling at 5 m height above ground. The campaign lasted nearly 1 year from July 2012 to June 2013 as part of the EU-FP7-ACTRIS project (Q-ACSM Network. Including equivalent black carbon an average particulate mass concentration of 9.50 µg m−3 was obtained during the whole campaign with dominant contributions from ammonium nitrate (45 %, organic aerosol (OA, 29 %, and ammonium sulfate (19 %. There were 12 exceedances of the World Health Organization (WHO PM2.5 daily mean limit (25 µg m−3 observed at this rural site using PM1 instrumentation only. Ammonium nitrate and OA represented the largest contributors to total particulate matter during periods of exceedance. Source apportionment of OA was performed season-wise by positive matrix factorization (PMF using the multilinear engine 2 (ME-2 controlled via the source finder (SoFi. Primary organic aerosols were attributed mainly to traffic (8–16 % contribution to total OA, averaged season-wise and biomass burning (0–23 %. Secondary organic aerosols (SOAs, 61–84 % dominated the organic fraction during the whole campaign, particularly on days with high mass loadings. A SOA factor which is attributed to humic-like substances (HULIS was identified as a highly oxidized background aerosol in Cabauw. This shows the importance of atmospheric aging processes for aerosol concentration at this rural site. Due to the large secondary fraction, the reduction of particulate mass at this rural site is challenging on a local scale.

  9. Back-trajectory modeling of high time-resolution air measurement data to separate nearby sources

    Strategies to isolate air pollution contributions from sources is of interest as voluntary or regulatory measures are undertaken to reduce air pollution. When different sources are located in close proximity to one another and have similar emissions, separating source emissions ...

  10. Generalised perturbation theory and source of information through chemical measurements

    Lelek, V.; Marek, T.

    2001-01-01

    It is important to make all analyses and collect all information from the work of the new facility (which the transmutation demonstration unit will surely be) to be sure that the operation corresponds to the forecast or to correct the equations of the facility. The behaviour of the molten salt reactor and in particular the system of measurement are very different from that of the solid fuel reactor. Key information from the long time kinetics could be the nearly on line knowledge of the fuel composition. In this work it is shown how to include it into the control and use such data for the correction of neutron cross-sections for the high actinides or other characteristics. Also the problem of safety - change of the boundary problem to the initial problem - is mentioned. The problem is transformed into the generalised perturbation theory in which the adjoint function is obtained through the solution of the equations with right hand side having the form of source. Such an approach should be a theoretical base for the calculation of the sensitivity coefficients. (authors)

  11. A MOX fuel attribute monitor

    Bliss, Mary; Jordan, David V.; Barnett, Debra S.; Redding, Rebecca L.; Pearce, Stephen K.

    2007-01-01

    Euratom performs safeguards monitoring of Fresh MOX fuel for domestic power production in the European Union. Video cameras monitor the reactor storage ponds. If video surveillance is lost for a certain amount of time a measurement is required to verify that no fuel was diverted. The attribute measurement to verify the continued presence of MOX fuel is neutron emission. Ideally this measurement would be made without moving or handling the fuel rod assembly. A prototype attribute measurement system was made using scintillating neutron sensitive glass waveguides developed by Pacific Northwest National Laboratory. Short lengths (5-20 cm) of the neutron sensitive fiber were mechanically spliced to 15 m lengths of commercial high numerical aperture fiber optic cable (Ceramoptec Optran Ultra 0.44). The light detector is a Hamamatsu R7400P photomultiplier tube. An electronics package was built to use the sensors with a GBS Elektronik MCA-166 multichannel analyzer and user interface. The MCA-166 is the system most commonly used by Euratom inspectors. It can also be run from a laptop computer using Maestro (Ortec) or other software. A MCNP model was made to compare to measurements made with several neutron sources including NIST traceable 252 Cf

  12. Radioactivity measurements in Egyptian Phosphate Mines and Their Significance As a Source of Hazardous Radioactive Waste

    Hussein, A.Z.; Hussein, M.I.; Abdel Hady, M.L.

    1999-01-01

    Phosphate mines that may contain radioactive traces in the composition of their ores represent source of hazardous radioactive waste in the environment. Radioactivity measurements have been conducted in nine underground phosphate mines in the Egyptian Eastern Desert in order to estimate the occupational radiation exposure of mine workers in those mining sites. Measurements were carried out of airborne radon and its short- lived decay products (progeny) and thoron progeny, as well as radiation from mines walls, ceilings and floors. Conventional, well established techniques, methods and instrumentation were used to make these measurements. Comparison of experimental data and theoretical predictions showed partial agreement between these two sets of data. This result is partly attributed to the complex layout of these mines, which causes undesirable ventilation conditions, such as recirculation airflow patterns, which could not be adequately identified or quantified. The radiation data obtained were used to estimate the maximum Annual Dose (MAD), and other important occupational radiation exposure variables. These calculations indicate that in eight out of the nine mines surveyed, the MAD exceeded (by a factor of up to 7) the maximum recommended level by ICRP 60. Numbers of suggestions are made in order to reduce the MAD in the affected mines. This study could help in the estimation of the environmental impact of these mine operations on the environment

  13. Optimal Measurement Conditions for Spatiotemporal EEG/MEG Source Analysis.

    Huizenga, Hilde M.; Heslenfeld, Dirk J.; Molenaar, Peter C. M.

    2002-01-01

    Developed a method to determine the required number and position of sensors for human brain electromagnetic source analysis. Studied the method through a simulation study and an empirical study on visual evoked potentials in one adult male. Results indicate the method is fast and reliable and improves source precision. (SLD)

  14. Measurement of the equivalent fundamental-mode source strength

    Spriggs, G.D.; Busch, R.D.

    1997-01-01

    The steady-state multiplication, M, of a subcritical system that is in equilibrium with an external/intrinsic source is defined as the total neutron-production rate divided by the external/ intrinsic neutron source rate, S. The total neutron-production rate, in this context, is the sum of the fission-production rate plus the source rate. Because the system is in equilibrium, the total neutron-production rate is identically equal to the loss rate from the system due to absorption plus leakage. If the source S is distributed identically to the fission source distribution (i.e., angle, energy, and space), then M will be related to the effective multiplication factor of the system, k eff , as M = 1/1-k eff

  15. Fugitive Methane Emission Identification and Source Attribution: Ethane-to-Methane Analysis Using a Portable Cavity Ring-Down Spectroscopy Analyzer

    Kim-Hak, D.; Fleck, D.

    2017-12-01

    Natural gas analysis and methane specifically have become increasingly important by virtue of methane's 28-36x greenhouse warming potential compared to CO2 and accounting for 10% of total greenhouse gas emissions in the US alone. Additionally, large uncontrolled leaks, such as the recent one from Aliso Canyon in Southern California, originating from uncapped wells, storage facilities and coal mines have increased the total global contribution of methane missions even further. Determining the specific fingerprint of methane sources by quantifying the ethane to methane (C2:C1) ratios provides us with means to understand processes yielding methane and allows for sources of methane to be mapped and classified through these processes; i.e. biogenic or thermogenic, oil vs. gas vs. coal gas-related. Here we present data obtained using a portable cavity ring-down spectrometry analyzer weighing less than 25 lbs and consuming less than 35W that simultaneously measures methane and ethane in real-time with a raw 1-σ precision of plane gas propagation.

  16. Resolution and drift measurements on the Advanced Photon Source beam position monitors

    Chung, Y.; Kahana, E.

    1994-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N = 2 n , n = 1, 2, ... , 11). Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√ N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed

  17. Resolution and drift measurements on the advanced photon source beam position monitor

    Chung, Y.; Kahana, E.

    1995-01-01

    The resolution and long-term drift of the Advanced Photon Source (APS) beam position monitor (BPM) electronics were measured using the charged particle beams in the ESRF storage ring with various beam current and configurations (single bunch, 8 and 16 equally spaced bunches, and 1/3-fill). The energy of the stored electrons was 6 GeV. The integrated BPM electronics system as used for this work is capable of measuring the beam position on a turn-by-turn basis, which can be accumulated for N turns (N=2 n , n=1,2,...,11) . Estimation of the BPM resolution apart from the low-frequency beam motion was made by measuring the standard deviation in the measured beam position with different Ns. The analysis of the results indicates a BPM resolution of 18/√N [μm] for the APS storage ring, which is equivalent to 0.07 μm/√Hz. For the miniature insertion device BPM with 2.8 times higher sensitivity, the resolution will be 0.02 μm/√Hz. The long-term drift of the BPM electronics independent of the actual beam motion was measured at 2 μm/hr, which settled after approximately 1.5 hours. This drift can be attributed mainly to the temperature effect. Comparison of the results with the laboratory measurements shows good agreement. Implication of the BPM resolution limit on the proposed global and local beam position feedback systems for the APS storage ring will also be discussed. copyright 1995 American Institute of Physics

  18. Measurement and apportionment of radon source terms for modeling indoor environments

    Harley, N.H.

    1990-01-01

    This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters

  19. Environmental radioactivity in Caithness and Sutherland. Pt. 1: Food-chain model validation and the attribution of radionuclide sources to deposition

    Rose, C.L.; Halliwell, C.M.

    1995-01-01

    This study is part of a continuing programme investigating the behaviour of environmental radioactivity in the vicinity of the AEA Technology establishment at Dounreay, Caithness and Sutherland. The study aims were to assess the applicability of a National Radiological Protection Board (NRPB) food-chain model to the Caithness and Sutherland area, and to determine the contribution of different radionuclide sources to activities in measured total deposition in the same region. The NRPB model predicts the movement of radionuclides through the food-chain, and in this study was validated by comparing model outputs with measured crop data (ryegrass and clover). Five radionuclides ( 137 Cs, 90 Sr, 239+240 Pu, 238 Pu, 241 Am) were considered. The contribution of different radionuclide sources to activities in total deposition were divided into three categories: Dounreay stack inputs, sea-to-land transfer, and the combined contribution from nuclear weapons testing and Chernobyl fallout. The analyses indicated that the contribution of the Dounreay stack to total deposition was very small for the radionuclides studied. The Chernobyl accident made a large impact on the total deposition of 137 Cs in the study area, and 90 Sr deposition was also affected by this, but to a much lesser extent. The Chernobyl accident appeared to have no effect on total Pu deposition in the region. The cessation of nuclear weapons testing and the length of time since Chernobyl meant that actual 137 Cs and 90 Sr deposition as a result of weapons/Chernobyl inputs had reached a low level by the end of the study period (summer 1987). It became evident that a contribution to total deposition was being made by additional factors, thought to be local resuspension of large particles for 137 Cs, and possibly deposition of plant material for 90 Sr. For Pu, sea-to-land transfer was probably an important contributor at coastal sites. (Author)

  20. Antimalarial measures - type, sources of advice and compliance ...

    1994-06-01

    Jun 1, 1994 ... pharmacies as well as actual behaviour in this regard and sources of advice accessed ... pharmacies and 53 'care providers' (members of travel parties). Doctors ... TPS Drug Information Services, Johannesburg. L Baker, DIP.

  1. National Management Measures to Control Nonpoint Source Pollution from Forestry

    This report helps forest owners protect lakes and streams from polluted runoff that can result from forestry activities. The report will also help states to implement their nonpoint source control programs.

  2. Challenges and Opportunities for Using Crowd-Sourced Air Pollution Measurements for Education and Outreach

    Stanier, C. O.; Dong, C.; Janechek, N. J.; Bryngelson, N.; Schultz, P.; Heimbinder, M.

    2017-12-01

    As part of the CLE4R air quality education project, the University of Iowa has been working with AirBeam low-cost consumer-grade fine particulate matter (PM2.5) sensors in educational and outreach settings, both in K-12 environments and in informal settings such as science days and technology fairs. Users are attracted to the AirBeam device, in part, because of the easy creation of crowd-sourced maps of air pollution. With over 1000 AirBeam devices in use, extensive measurements are now available at aircasting.org. The AirBeam sensor is a portable, low-cost sensor which measures light scattering due to aerosols as a single bin converting the detected signal to a particle count and uses a calibration fit to estimate particle mass. The AirBeam is able to detect particle sizes of 0.5 - 2.5 µm, concentrations up to 400 µg m-3, and with a time resolution of 1 s. A corresponding Android device is used to visualize, record, and upload measured data to a community website (aircasting.org) that maps the spatial and temporal resolved data. The non-profit vendor's website constructs crowdsourced maps of air quality, environmental, and meteorological variables. As of April 1st, 2017, through the CLE4R project, 109 people had used the AirBeam sensors for educational purposes, for a total of 271 person hours. In the poster, we will explain the outreach that was done, and share best practices for education and outreach using consumer-grade PM sensors. Strengths and needed improvements to the technology for these outreach, education, and classroom uses will also be detailed. Sources of particles that can be artificially generated for educational use, including authentic smoke, spray smoke, and various dust sources will be enumerated. For use in K-12 classrooms, requirements for robust startup, operation, and ease-of-use are high. Mapping of concentrations is a desirable attribute but adds additional sources of failure to the hardware-software system used for education/outreach.

  3. Neutron source strength determination for on-line reactivity measurements

    Hoogenboom, J.E.; Sluijs, A.R. van der

    1988-01-01

    A method is described to determine the effective neutron source strength in a nuclear reactor, which must be known when calculating the time-varying reactivity from inverse reactor kinetics for a reactor at low power. When for an initially subcritical reactor the reactivity is changed and kept constant after the change, the effective source strength can be determined from a linear regression of reactor power to a function proportional to the emission rate of delayed neutrons, which can be calculated from the reactor power history. In view of the relatively strong noise present in the reactor power signal at low power, a grouping method for the regression is preferred over the least-squares method. Experiments with a reactor simulator with known source strength showed good agreement. Application to actual reactor signals gave consistent and satisfactory results.

  4. Protocol of source shielding maintenance in a level measurement systems

    Gonzales, E.; Figueroa, J.

    1996-01-01

    Maintenance labor of the source shielding and locking system is not performed in many Venezuelan enterprises that employ radioactive level gauge in large container. The lack of maintenance and the ambient long lasting action have produced impairment of many devices and their given parts rise to economical and radiological protection problems. In order to help to solve the mentioned problems, principally to reduce the unjustified dose to workers, the IVIC Health Physics Service worked out a protocol to perform, in a safety way, the maintenance of source shielding and its locking system. This protocol is presented in this paper. (authors)

  5. Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source

    Rivard, Mark J.; Davis, Stephen D.; DeWerd, Larry A.; Rusch, Thomas W.; Axelrod, Steve

    2006-01-01

    A new x-ray source, the model S700 Axxent trade mark sign X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, P (5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1 125 I and 103 Pd, yet with capability for variable and much higher dose rates and subsequently adjustable penetration capabilities. This paper presents the calculated and measured in-water brachytherapy dosimetry parameters for the model S700 Source at the aforementioned three operating voltages

  6. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    C. B. Alden

    2018-03-01

    Full Text Available Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m, integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB. The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1 a non-leaking source location and (2 a source location where a controlled emission of 3.1  ×  10−5 kg s−1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests. The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability and measurement uncertainty of 5 ppb (1σ, when

  7. Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

    Alden, Caroline B.; Ghosh, Subhomoy; Coburn, Sean; Sweeney, Colm; Karion, Anna; Wright, Robert; Coddington, Ian; Rieker, Gregory B.; Prasad, Kuldeep

    2018-03-01

    Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model-data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10-5 kg s-1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4+ km2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1σ), when measurements are averaged over 2 min. The

  8. Measurement of radon in Spanish houses: characterization of its sources

    1998-01-01

    The determination of radon concentrations in-house are analyzed by different universities. The programs of Cantabria, Valencia, Barcelona and La Laguna Universities are presented. These programs study the environmental impact of radon in Barcelona and Madrid and characterize the radon sources

  9. Human Campylobacteriosis in Luxembourg, 2010?2013: A Case-Control Study Combined with Multilocus Sequence Typing for Source Attribution and Risk Factor Analysis

    Mossong, Jo?l; Mughini-Gras, Lapo; Penny, Christian; Devaux, Anthony; Olinger, Christophe; Losch, Serge; Cauchie, Henry-Michel; van Pelt, Wilfrid; Ragimbeau, Catherine

    2016-01-01

    Campylobacteriosis has increased markedly in Luxembourg during recent years. We sought to determine which Campylobacter genotypes infect humans, where they may originate from, and how they may infect humans. Multilocus sequence typing was performed on 1153 Campylobacter jejuni and 136 C. coli human strains to be attributed to three putative animal reservoirs (poultry, ruminants, pigs) and to environmental water using the asymmetric island model. A nationwide case-control study (2010?2013) for...

  10. Stable source reconstruction from a finite number of measurements in the multi-frequency inverse source problem

    Karamehmedovic, Mirza; Kirkeby, Adrian; Knudsen, Kim

    2018-01-01

    setting: From measurements made at a finite set of frequencies we uniquely determine and reconstruct sources in a subspace spanned by finitely many Fourier-Bessel functions. Further, we obtain a constructive criterion for identifying a minimal set of measurement frequencies sufficient for reconstruction......, and under an additional, mild assumption, the reconstruction method is shown to be stable." Our analysis is based on a singular value decomposition of the source-to-measurement forward operators and the distribution of positive zeros of the Bessel functions of the first kind. The reconstruction method...

  11. Psychometric attributes of the Cervantes short-form questionnaire for measuring health-related quality of life in menopausal women.

    Coronado, Pluvio J; Sánchez-Borrego, Rafael; Ruiz, Miguel A; Baquedano, Laura; Sánchez, Sonia; Argudo, Cristina; Fernández-Abellán, Mariela; González, Silvia; Iglesias, Eva; Calleja, Jackie; Presa, Jesus; Duque, Alfonso; Ruiz, Fernando; Otero, Borja; Rejas, Javier

    2016-02-01

    To analyse the psychometric properties of the Cervantes scale short-form (SF) in the peri- and post-menopausal periods. Outpatients women 45-65 years with menstrual problems associated with the climacteric syndrome were analysed. Original and SF versions of the Cervantes scale were administered along with the EuroQol-5D (EQ-5D) and work productivity and activity impairment questionnaire (WPAI) scales. Conceptual model, burden of administration, feasibility, reliability, criteria validity and construct validity were assessed. 317 women [55.7±5.3 years (mean±standard deviation)] were recruited: 75.4% were post- and 22.3% were peri-menopausal. The Cervantes-SF was completed in 2.5±1.6min, and 86% answered all items. Cronbach's α was 0.820, and ranged from 0.510 (Aging) to 0.918 (Vasomotor Symptoms) for individual dimensions. The scale structure matched the structure of the original version, χ(2)/(degrees of freedom)=3.6, Comparative Fit Index=0.848, Tucker-Lewis Index=0.850, and root mean square error of approximation=0.099, although differences were found between sexual activity statuses. Criteria validity was good (r=0.890), concurrent validity was congruent with a priori hypothesis using either the EQ-5D or the WPAI scales. The scale discriminated significantly the severity of both vasomotor and genital climacteric associated symptoms. The Cervantes-SF has shown good psychometric properties for measuring Health related quality of life in peri- and post-menopausal women who regularly attended gynaecology clinics in Spain. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Identifying and correcting epigenetics measurements for systematic sources of variation.

    Perrier, Flavie; Novoloaca, Alexei; Ambatipudi, Srikant; Baglietto, Laura; Ghantous, Akram; Perduca, Vittorio; Barrdahl, Myrto; Harlid, Sophia; Ong, Ken K; Cardona, Alexia; Polidoro, Silvia; Nøst, Therese Haugdahl; Overvad, Kim; Omichessan, Hanane; Dollé, Martijn; Bamia, Christina; Huerta, José Marìa; Vineis, Paolo; Herceg, Zdenko; Romieu, Isabelle; Ferrari, Pietro

    2018-01-01

    Methylation measures quantified by microarray techniques can be affected by systematic variation due to the technical processing of samples, which may compromise the accuracy of the measurement process and contribute to bias the estimate of the association under investigation. The quantification of

  13. Volatile organic compounds in Tijuana during the Cal-Mex 2010 campaign: Measurements and source apportionment

    Zheng, Jun; Garzón, Jessica P.; Huertas, María E.; Zhang, Renyi; Levy, Misti; Ma, Yan; Huertas, José I.; Jardón, Ricardo T.; Ruíz, Luis G.; Tan, Haobo; Molina, Luisa T.

    2013-05-01

    As part of the Cal-Mex 2010 air quality study, a proton transfer reaction-mass spectrometer (PTR-MS) was deployed at the San Diego-Tijuana border area to measure volatile organic compounds (VOCs) from 15 May to 30 June 2010. The major VOCs identified during the study included oxygenated VOCs (e.g., methanol, acetaldehyde, acetone, and methyl ethyl ketone) and aromatics (e.g., benzene, toluene, C8- and C9-aromatics). Biogenic VOCs (e.g., isoprene) were scarce in this region because of the lack of vegetation in this arid area. Using an U.S. EPA positive matrix factorization model, VOCs together with other trace gases (NOx, NOz and SO2) observed in this border region were attributed to four types of sources, i.e., local industrial solvent usage (58% in ppbC), gasoline vehicle exhaust (19% in ppbC), diesel vehicle exhaust (14% in ppbC), and aged plume (9% in ppbC) due to regional background and/or long-range transport. Diesel vehicle emission contributed to 87% of SO2 and 75% of NOx, and aged plume contributed to 92% of NOz. An independent conditional probability function analysis of VOCs, wind direction, and wind speed indicated that the industrial source did not show a significant tendency with wind direction. Both gasoline and diesel engine emissions were associated with air masses passing through two busy cross-border ports. Aged plumes were strongly associated with NW wind, which likely brought in aged air masses from the populated San Diego area.

  14. Orbital electron capture measurements with an internal-source spectrometer

    Gerner, C.P.

    1978-01-01

    Electron-capture measurements have been performed on 131 Ba and on 106 Agsup(m). For 131 Ba the L/K-and M/L-capture rations of the allowed decay have been measured to the 1048 keV level in 131 Cs. The Qsub(EC) value, the exchange- and overlap-correction factors Xsup(L/K) and Xsup(M/L) and the reduced capture ratios have been determined. For 106 Agsup(m) the L/K-capture ratio of the allowed decay has been measured to the 2757 keV level in 106 Pd. The Q value, the exchange- and overlap-correction factor Xsup(L/K) and the reduced L/K- capture ratio have been derived. The measurements indicate that agreement between experimentally determined capture ratios and exchange-corrected theoretical predictions is fairly good, both for allowed and for first-forbidden non-unique transitions. (Auth./C.F.)

  15. Gamma-ray measurements at the WNR white neutron source

    Nelson, R.O.; Wender, S.A.; Mayo, D.R.

    1994-01-01

    Photon production data have been acquired in the incident neutron energy range, 1 n γ 56 Fe, and 207,208 Pb. These data are useful both for testing nuclear reaction models at intermediate energies and for numerous applied purposes. BGO detectors do not have the good energy resolution of Ge detectors, but have much greater detection efficiency for gamma rays with energies greater than a few MeV. We have used an array of 5 BGO detectors to measure cross sections and angular distributions for photon production from C and N. A large, well-shielded BGO detector has been used to measure fast neutron capture in the giant resonance region with a maximum gamma-ray energy of 52 MeV. We present results of our study of the isovector giant quadrupole resonance in 41 Ca via these capture measurements. Recent measurements of inclusive photon spectra from our neutron proton Bremsstrahlung experiment have been made using a gamma-ray telescope to detect gamma-rays in the energy range, 40 γ < 300 MeV. This detector is briefly described. The advantages and disadvantages of these detector systems are discussed using examples from our measurements. The status of current measurements is presented

  16. 76 FR 53897 - EPA Seeking Input Materials Measurement; Municipal Solid Waste (MSW), Recycling, and Source...

    2011-08-30

    ... Measurement; Municipal Solid Waste (MSW), Recycling, and Source Reduction Measurement in the U.S. AGENCY... Subjects Environmental protection, municipal solid waste (MSW) characterization, MSW management, recycling, measurement, data, data collection, construction and demolition (C&D) recycling, source reduction, life cycle...

  17. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  18. Measurement and apportionment of radon source terms for modeling indoor environments

    Harley, N.H.

    1992-01-01

    This research has two main goals; (1) to quantify mechanisms for radon entry into homes of different types and to determine the fraction of indoor radon attributable to each source and (2) to model and calculate the dose (and therefore alpha particle fluence) to cells in the human and animal tracheobronchial tree that is pertinent to induction of bronchogenic carcinoma from inhaled radon daughters. The dosimetry has been extended to include organs other than the lung

  19. Measures to remove impediments to better utilization. Renewable energy sources

    Diekmann, J.; Eichelbroenner, M.; Langniss, O.

    1997-01-01

    The utilization of renewable energy sources meets with a number of obstacles created in particular by economic framework conditions, regulatory provisions, lengthy administrative procedures, insufficient information, and to some part also to the reluctance of bankers and utilities. This is why an action programme was put underway by the Forum fuer Zukunftsenergien, together with the Berlin-based DIW (German economic research institute) and the Stuttgart-based DLR (German aerospace research institute), financed from public funds of the Federal Ministry of Economics. Under this programme, almost 900 operators of systems for electricity generation from wind power, hydropower, biomass, ambient heat, solar thermal energy and by photovoltaic conversion have been interviewed. Based on the information obtained, the article reveals the existing impediments and proposed action for overcoming the obstacles. (orig.) [de

  20. Social attribution test--multiple choice (SAT-MC) in schizophrenia: comparison with community sample and relationship to neurocognitive, social cognitive and symptom measures.

    Bell, Morris D; Fiszdon, Joanna M; Greig, Tamasine C; Wexler, Bruce E

    2010-09-01

    This is the first report on the use of the Social Attribution Task - Multiple Choice (SAT-MC) to assess social cognitive impairments in schizophrenia. The SAT-MC was originally developed for autism research, and consists of a 64-second animation showing geometric figures enacting a social drama, with 19 multiple choice questions about the interactions. Responses from 85 community-dwelling participants and 66 participants with SCID confirmed schizophrenia or schizoaffective disorders (Scz) revealed highly significant group differences. When the two samples were combined, SAT-MC scores were significantly correlated with other social cognitive measures, including measures of affect recognition, theory of mind, self-report of egocentricity and the Social Cognition Index from the MATRICS battery. Using a cut-off score, 53% of Scz were significantly impaired on SAT-MC compared with 9% of the community sample. Most Scz participants with impairment on SAT-MC also had impairment on affect recognition. Significant correlations were also found with neurocognitive measures but with less dependence on verbal processes than other social cognitive measures. Logistic regression using SAT-MC scores correctly classified 75% of both samples. Results suggest that this measure may have promise, but alternative versions will be needed before it can be used in pre-post or longitudinal designs. (c) 2009 Elsevier B.V. All rights reserved.

  1. Validation of a standard forensic anthropology examination protocol by measurement of applicability and reliability on exhumed and archive samples of known biological attribution.

    Francisco, Raffaela Arrabaça; Evison, Martin Paul; Costa Junior, Moacyr Lobo da; Silveira, Teresa Cristina Pantozzi; Secchieri, José Marcelo; Guimarães, Marco Aurelio

    2017-10-01

    Forensic anthropology makes an important contribution to human identification and assessment of the causes and mechanisms of death and body disposal in criminal and civil investigations, including those related to atrocity, disaster and trafficking victim identification. The methods used are comparative, relying on assignment of questioned material to categories observed in standard reference material of known attribution. Reference collections typically originate in Europe and North America, and are not necessarily representative of contemporary global populations. Methods based on them must be validated when applied to novel populations. This study describes the validation of a standardized forensic anthropology examination protocol by application to two contemporary Brazilian skeletal samples of known attribution. One sample (n=90) was collected from exhumations following 7-35 years of burial and the second (n=30) was collected following successful investigations following routine case work. The study presents measurement of (1) the applicability of each of the methods: used and (2) the reliability with which the biographic parameters were assigned in each case. The results are discussed with reference to published assessments of methodological reliability regarding sex, age and-in particular-ancestry estimation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. The assessment of source attribution of soil pollution in a typical e-waste recycling town and its surrounding regions using the combined organic and inorganic dataset.

    Luo, Jie; Qi, Shihua; Xie, Xianming; Gu, X W Sophie; Wang, Jinji

    2017-01-01

    Guiyu is a well-known electronic waste dismantling and recycling town in south China. Concentrations and distribution of the 21 mineral elements and 16 polycyclic aromatic hydrocarbons (PAHs) collected there were evaluated. Principal component analyses (PCA) applied to the data matrix of PAHs in the soil extracted three major factors explaining 85.7% of the total variability identified as traffic emission, coal combustion, and an unidentified source. By using metallic or metalloid element concentrations as variables, five principal components (PCs) were identified and accounted for 70.4% of the information included in the initial data matrix, which can be denoted as e-waste dismantling-related contamination, two different geological origins, anthropogenic influenced source, and marine aerosols. Combining the 21 metallic and metalloid element datasets with the 16 PAH concentrations can narrow down the coarse source and decrease the unidentified contribution to soil in the present study and therefore effectively assists the source identification process.

  3. Measurements on the source properties of a hollow cathode

    Vogels, J.M.M.J.; Konings, L.U.E.; Koelman, J.M.V.A.; Schram, D.C.; Bötticher, W.; Wenk, H.; Schulz-Gulde, E.

    1983-01-01

    The ion production rate of a hollow cathode in a magnetized arc has been measured. At low magnetic fields supersonic ion drifts have been observed. The ionized fraction of the gas flow decreases with increasing flow and the ion flux saturates at high flow rates

  4. Use of radioactive sources in measuring characteristics of snowpacks

    Henry W. Anderson; Philip M. McDonald; Lloyd W. Gay

    1963-01-01

    Use of radioactive probes inserted in mountain snowpacks may make possible more accurate appraisal and prediction of snowmelt water. Commercially available gamma and neutron probes were tested for their ability to measure snow density, ice lenses, and the thermal quality of individual layers in the snowpack.

  5. A review of international sources for road safety measures assessment.

    Yannis, G. Weijermars, W. & Kauppila, J.

    2012-01-01

    The efficiency assessment of road safety measures is considered to be an extremely useful tool in decision making; in particular, cost-benefit and cost-effectiveness analyses are carried out in several countries, in a more or less systematic way. The objective of this paper is to present findings

  6. Sources of errors in the measurements of underwater profiling radiometer

    Silveira, N.; Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; Lotlikar, A.

    to meet the stringent quality requirements of marine optical data for satellite ocean color sensor validation, development of algorithms and other related applications, it is very essential to take great care while measuring these parameters. There are two... of the pelican hook. The radiometer dives vertically and the cable is paid out with less tension, keeping in tandem with the descent of the radiometer while taking care to release only the required amount of cable. The operation of the release mechanism lever...

  7. Global-scale attribution of anthropogenic and natural dust sources and their emission rates based on MODIS Deep Blue aerosol products

    Ginoux, Paul; Prospero, Joseph M.; Gill, Thomas E.; Hsu, N. Christina; Zhao, Ming

    2012-09-01

    Our understanding of the global dust cycle is limited by a dearth of information about dust sources, especially small-scale features which could account for a large fraction of global emissions. Here we present a global-scale high-resolution (0.1°) mapping of sources based on Moderate Resolution Imaging Spectroradiometer (MODIS) Deep Blue estimates of dust optical depth in conjunction with other data sets including land use. We ascribe dust sources to natural and anthropogenic (primarily agricultural) origins, calculate their respective contributions to emissions, and extensively compare these products against literature. Natural dust sources globally account for 75% of emissions; anthropogenic sources account for 25%. North Africa accounts for 55% of global dust emissions with only 8% being anthropogenic, mostly from the Sahel. Elsewhere, anthropogenic dust emissions can be much higher (75% in Australia). Hydrologic dust sources (e.g., ephemeral water bodies) account for 31% worldwide; 15% of them are natural while 85% are anthropogenic. Globally, 20% of emissions are from vegetated surfaces, primarily desert shrublands and agricultural lands. Since anthropogenic dust sources are associated with land use and ephemeral water bodies, both in turn linked to the hydrological cycle, their emissions are affected by climate variability. Such changes in dust emissions can impact climate, air quality, and human health. Improved dust emission estimates will require a better mapping of threshold wind velocities, vegetation dynamics, and surface conditions (soil moisture and land use) especially in the sensitive regions identified here, as well as improved ability to address small-scale convective processes producing dust via cold pool (haboob) events frequent in monsoon regimes.

  8. On the usability of frequency distributions and source attribution of Cs-137 detections encountered in the IMS radio-nuclide network for radionuclide event screening and climate change monitoring

    Becker, A.; Wotawa, G.; Zähringer, M.

    2009-04-01

    Under the provisions of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), airborne radioactivity is measured by means of high purity Germanium gamma ray detectors deployed in a global monitoring network. Almost 60 of the scheduled 80 stations have been put in provisional operations by the end of 2008. Each station daily sends the 24 hour samples' spectroscopic data to the Vienna based Provisional Technical Secretariat (PTS) of the CTBT Organization (CTBTO) for review for treaty-relevant nuclides. Cs-137 is one of these relevant isotopes. Its typical minimum detectable concentration is in the order of a few Bq/m3. However, this isotope is also known to occur in atmospheric trace concentrations, due to known non CTBT relevant processes and sources related to, for example, the re-suspension of cesium from historic nuclear tests and/or the Chernobyl reactor disaster, temporarily enhanced by bio-mass burning (Wotawa et al. 2006). Properly attributed cesium detections can be used as a proxy to detect Aeolian dust events (Igarashi et al, 2001) that potentially carry cesium from all aforementioned sources but are also known to play an important role for the radiative forcing in the atmosphere (shadow effect), at the surface (albedo) and the carbon dioxide cycle when interacting with oceanic phytoplankton (Mikami and Shi, 2005). In this context this paper provides a systematic attribution of recent Cs-137 detections in the PTS monitoring network in order to Characterize those stations which are regularly affected by Cs-137 Provide input for procedures that distinguish CTBT relevant detection from other sources (event screening) Explore on the capability of certain stations to use their Cs-137 detections as a proxy to detect aeolian dust events and to flag the belonging filters to be relevant for further investigations in this field (-> EGU-2009 Session CL16/AS4.6/GM10.1: Aeolian dust: initiator, player, and recorder of environmental change). References Igarashi, Y., M

  9. Magnetic measurements of the injector synchrotron magnets for the Advanced Photon Source

    Kim, S.H.; Carnegie, D.W.; Doose, C.L.; Hogrefe, R.; Kim, K.; Merl, R.; Turner, L.R.

    1993-01-01

    The magnetic measurement data of the dipole, quadrupole, and sextupole magnets for the Advanced Photon Source injector synchrotron are summarized. Magnet design and magnetic measurements of the field strength, field shape, and multipole coefficients are described

  10. Magnetic measurements of the injector synchrotron magnets for the advanced photon source

    Kim, S. H.; Carnegie, D. W.; Doose, C. L.; Hogrefe, R.; Kim, K.; Merl, R.; Turner, L. R.

    1994-07-01

    The magnetic measurement data of the dipole, quadrupole, and sextupole magnets for the Advanced Photon Source injector synchrotron are summarized. Magnet design and magnetic measurements of the field strength, field shape, and multipole coefficients are described.

  11. Measured Performance of a Low Temperature Air Source Heat Pump

    Johnson, R. K. [Johnson Research LLC, Pueblo West, CO (United States)

    2013-09-01

    A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system's Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.

  12. Sources and performance criteria of uncertainty of reference measurement procedures.

    Mosca, Andrea; Paleari, Renata

    2018-05-29

    This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018

  13. 2π absolute measurement research for α-electroplating source covering ZnS(Ag)

    Zhu Tianxia

    1999-01-01

    2π absolute measurement can be completed after the quantitative deposit (5 +- 1) mg/cm 2 with ZnS(Ag) on surface of the alpha electroplating source. The measuring efficiency is 100%. This method is suitable for both of electroplating ordinary sample and electroplating standard (of reference) source

  14. A Novel Relevance Feedback Approach Based on Similarity Measure Modification in an X-Ray Image Retrieval System Based on Fuzzy Representation Using Fuzzy Attributed Relational Graph

    Hossien Pourghassem

    2011-04-01

    Full Text Available Relevance feedback approaches is used to improve the performance of content-based image retrieval systems. In this paper, a novel relevance feedback approach based on similarity measure modification in an X-ray image retrieval system based on fuzzy representation using fuzzy attributed relational graph (FARG is presented. In this approach, optimum weight of each feature in feature vector is calculated using similarity rate between query image and relevant and irrelevant images in user feedback. The calculated weight is used to tune fuzzy graph matching algorithm as a modifier parameter in similarity measure. The standard deviation of the retrieved image features is applied to calculate the optimum weight. The proposed image retrieval system uses a FARG for representation of images, a fuzzy matching graph algorithm as similarity measure and a semantic classifier based on merging scheme for determination of the search space in image database. To evaluate relevance feedback approach in the proposed system, a standard X-ray image database consisting of 10000 images in 57 classes is used. The improvement of the evaluation parameters shows proficiency and efficiency of the proposed system.

  15. Measuring Burden of Unhealthy Behaviours Using a Multivariable Predictive Approach: Life Expectancy Lost in Canada Attributable to Smoking, Alcohol, Physical Inactivity, and Diet.

    Manuel, Douglas G; Perez, Richard; Sanmartin, Claudia; Taljaard, Monica; Hennessy, Deirdre; Wilson, Kumanan; Tanuseputro, Peter; Manson, Heather; Bennett, Carol; Tuna, Meltem; Fisher, Stacey; Rosella, Laura C

    2016-08-01

    Behaviours such as smoking, poor diet, physical inactivity, and unhealthy alcohol consumption are leading risk factors for death. We assessed the Canadian burden attributable to these behaviours by developing, validating, and applying a multivariable predictive model for risk of all-cause death. A predictive algorithm for 5 y risk of death-the Mortality Population Risk Tool (MPoRT)-was developed and validated using the 2001 to 2008 Canadian Community Health Surveys. There were approximately 1 million person-years of follow-up and 9,900 deaths in the development and validation datasets. After validation, MPoRT was used to predict future mortality and estimate the burden of smoking, alcohol, physical inactivity, and poor diet in the presence of sociodemographic and other risk factors using the 2010 national survey (approximately 90,000 respondents). Canadian period life tables were generated using predicted risk of death from MPoRT. The burden of behavioural risk factors attributable to life expectancy was estimated using hazard ratios from the MPoRT risk model. The MPoRT 5 y mortality risk algorithms were discriminating (C-statistic: males 0.874 [95% CI: 0.867-0.881]; females 0.875 [0.868-0.882]) and well calibrated in all 58 predefined subgroups. Discrimination was maintained or improved in the validation cohorts. For the 2010 Canadian population, unhealthy behaviour attributable life expectancy lost was 6.0 years for both men and women (for men 95% CI: 5.8 to 6.3 for women 5.8 to 6.2). The Canadian life expectancy associated with health behaviour recommendations was 17.9 years (95% CI: 17.7 to 18.1) greater for people with the most favourable risk profile compared to those with the least favourable risk profile (88.2 years versus 70.3 years). Smoking, by itself, was associated with 32% to 39% of the difference in life expectancy across social groups (by education achieved or neighbourhood deprivation). Multivariable predictive algorithms such as MPoRT can be used

  16. PM10 source apportionment applying PMF and chemical tracer analysis to ship-borne measurements in the Western Mediterranean

    Bove, M. C.; Brotto, P.; Calzolai, G.; Cassola, F.; Cavalli, F.; Fermo, P.; Hjorth, J.; Massabò, D.; Nava, S.; Piazzalunga, A.; Schembari, C.; Prati, P.

    2016-01-01

    A PM10 sampling campaign was carried out on board the cruise ship Costa Concordia during three weeks in summer 2011. The ship route was Civitavecchia-Savona-Barcelona-Palma de Mallorca-Malta (Valletta)-Palermo-Civitavecchia. The PM10 composition was measured and utilized to identify and characterize the main PM10 sources along the ship route through receptor modelling, making use of the Positive Matrix Factorization (PMF) algorithm. A particular attention was given to the emissions related to heavy fuel oil combustion by ships, which is known to be also an important source of secondary sulphate aerosol. Five aerosol sources were resolved by the PMF analysis. The primary contribution of ship emissions to PM10 turned out to be (12 ± 4)%, while secondary ammonium sulphate contributed by (35 ± 5)%. Approximately, 60% of the total sulphate was identified as secondary aerosol while about 20% was attributed to heavy oil combustion in ship engines. The measured concentrations of methanesulphonic acid (MSA) indicated a relevant contribution to the observed sulphate loading by biogenic sulphate, formed by the atmospheric oxidation of dimethyl sulphide (DMS) emitted by marine phytoplankton.

  17. On-line Field Measurements of Speciated PM1 Emission Factors from Common South Asian Combustion Sources

    DeCarlo, P. F.; Goetz, J. D.; Giordano, M.; Stockwell, C.; Maharjan, R.; Adhikari, S.; Bhave, P.; Praveen, P. S.; Panday, A. K.; Jayarathne, T. S.; Stone, E. A.; Yokelson, R. J.

    2017-12-01

    Characterization of aerosol emissions from prevalent but under sampled combustion sources in South Asia was performed as part of the Nepal Ambient Monitoring and Source Testing Experiment (NAMaSTE) in April 2015. Targeted emission sources included cooking stoves with a variety of solid fuels, brick kilns, garbage burning, crop-residue burning, diesel irrigation pumps, and motorcycles. Real-time measurements of submicron non-refractory particulate mass concentration and composition were obtained using an Aerodyne mini Aerosol Mass Spectrometer (mAMS). Speciated PM1 mass emission factors were calculated for all particulate species (e.g. organics, sulfates, nitrates, chlorides, ammonium) and for each source type using the carbon mass balance approach. Size resolved emission factors were also acquired using a novel high duty cycle particle time-of-flight technique (ePTOF). Black carbon and brown carbon absorption emission factors and absorption Angström exponents were measured using filter loading and scattering corrected attenuation at 370 nm and 880 nm with a dual spot aethalometer (Magee Scientific AE-33). The results indicate that open garbage burning is a strong emitter of organic aerosol, black carbon, and internally mixed particle phase hydrogen chloride (HCl). Emissions of HCl were attributed to the presence chlorinated plastics. The primarily coal fired brick kilns were found to be large emitters of sulfate but large differences in the organic and light absorbing component of emissions were observed between the two kiln types investigated (technologically advanced vs. traditional). These results, among others, bring on-line and field-tested aerosol emission measurements to an area of atmoshperic research dominated by off-line or laboratory based measurements.

  18. Improved finite-source inversion through joint measurements of rotational and translational ground motions: a numerical study

    Reinwald, Michael; Bernauer, Moritz; Igel, Heiner; Donner, Stefanie

    2016-10-01

    With the prospects of seismic equipment being able to measure rotational ground motions in a wide frequency and amplitude range in the near future, we engage in the question of how this type of ground motion observation can be used to solve the seismic source inverse problem. In this paper, we focus on the question of whether finite-source inversion can benefit from additional observations of rotational motion. Keeping the overall number of traces constant, we compare observations from a surface seismic network with 44 three-component translational sensors (classic seismometers) with those obtained with 22 six-component sensors (with additional three-component rotational motions). Synthetic seismograms are calculated for known finite-source properties. The corresponding inverse problem is posed in a probabilistic way using the Shannon information content to measure how the observations constrain the seismic source properties. We minimize the influence of the source receiver geometry around the fault by statistically analyzing six-component inversions with a random distribution of receivers. Since our previous results are achieved with a regular spacing of the receivers, we try to answer the question of whether the results are dependent on the spatial distribution of the receivers. The results show that with the six-component subnetworks, kinematic source inversions for source properties (such as rupture velocity, rise time, and slip amplitudes) are not only equally successful (even that would be beneficial because of the substantially reduced logistics installing half the sensors) but also statistically inversions for some source properties are almost always improved. This can be attributed to the fact that the (in particular vertical) gradient information is contained in the additional motion components. We compare these effects for strike-slip and normal-faulting type sources and confirm that the increase in inversion quality for kinematic source parameters is

  19. Interpretation of the source-specific substantive control measures of the Minamata Convention on Mercury.

    You, Mingqing

    2015-02-01

    Being persistent, toxic, and bio-accumulative, Mercury (Hg) seriously affects the environment and human health. Due to Hg's attribute of long-range environmental transport across national borders, especially through atmospheric transport, no country can fully protect its environment and human health with its own efforts, without global cooperation. The Minamata Convention on Mercury, which was formally adopted and opened for signature in October 2013, is the only global environmental regime on the control of Hg pollution. Its main substantive control measures are source-specific: its phasing-out, phasing-down, and other main substantive requirements all direct to specific categories of pollution sources through the regulation of specific sectors of the economy and social life. This Convention does not take a national quota approach to quantify the Parties' nationwide total allowable consumption or discharge of Hg or Hg compounds, nor does it quantify their nationwide total reduction requirements. This paper attempts to find the underlying reasons for this source-specific approach and offers two interpretations. One possible interpretation is that Hg might be a non-threshold pollutant, i.e., a pollutant without a risk-free value of concentration. The existence of a reference dose (RfD), reference concentration (RfC), provisional tolerable weekly intake (PTWI), minimal risk level (MRL) or other similar reference values of Hg does not necessarily mean that Hg cannot be regarded as non-threshold because such reference values have scientific uncertainties and may also involve policy considerations. Another interpretation is that Hg lacks a feasibly determinable total allowable quantity. There is evidence that negotiators might have treated Hg as non-threshold, or at least accepted that Hg lacks a feasibly determinable total allowable quantity: (1) The negotiators were informed about the serious situations of the current emissions, releases, and legacy deposition; (2

  20. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  1. A portable measurement system for subcriticality measurements by the Cf-source-driven neutron noise analysis method

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1987-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the 252 Cf-source-driven neutron noise analysis method. 8 refs

  2. Localisation of a neutron source using measurements and calculation of the neutron flux and its gradient

    Linden, P; Dahl, B; Pázsit, I; Por, G

    1999-01-01

    We have performed laboratory measurements of the neutron flux and its gradient in a static model experiment, similar to a model problem proposed in Pazsit (Ann. Nucl. Energy 24 (1997) 1257). The experimental system consists of a radioactive neutron source located in a water tank. The measurements are performed using a recently developed very small optical fibre detector. The measured values of the flux and its gradient are then used to test the possibility of localising the source. The results show that it is possible to measure the flux on the circumference of a circle and from this calculate the flux gradient vector. Then, by comparison of the measured quantities with corresponding MCNP calculations, both the direction and the distance to the source are found and thus the position of the source can be determined.

  3. Tritium and the environment: sources, measurement and transfer; Le tritium et l'environnement: sources, mesures et transferts

    Guetat, P.; Douche, C.; Hubinois, J.C. [CEA Valduc, 21 - Is-sur-Tille (France)

    2008-10-15

    Within the framework of a seminar on environmental and health impact of tritium organized by article 31 EURATOM expert group in November 2007, it was expected to make a point on tritium knowledge and to define R and D and regulatory axes. This document presents the different sources of tritium, different methods of measurement associated to tritium processes and survey, transfer in the biosphere compartments in normal and accidental conditions. It suggests some R and D subjects and discusses some regulatory aspects. (authors)

  4. Enhancing the water management schemes of H08 global hydrological model to attribute human water use to six major water sources

    Hanasaki, N.; Yoshikawa, S.; Pokhrel, Y. N.; Kanae, S.

    2017-12-01

    Humans abstract water from various sources to sustain their livelihood and society. Some global hydrological models (GHMs) include explicit schemes of human water management, but the representation and performance of these schemes remain limited. We substantially enhanced the human water management schemes of the H08 GHM by incorporating the latest data and techniques. The model enables us to estimate water abstraction from six major water sources, namely, river flow regulated by global reservoirs (i.e., reservoirs regulating the flow of the world's major rivers), aqueduct water transfer, local reservoirs, seawater desalination, renewable groundwater, and nonrenewable groundwater. All the interactions were simulated in a single computer program and the water balance was always strictly closed at any place and time during the simulation period. Using this model, we first conducted a historical global hydrological simulation at a spatial resolution of 0.5 x 0.5 degree to specify the sources of water for humanity. The results indicated that, in 2000, of the 3628 km3yr-1 global freshwater requirement, 2839 km3yr-1 was taken from surface water and 789 km3yr-1 from groundwater. Streamflow, aqueduct water transfer, local reservoirs, and seawater desalination accounted for 1786, 199, 106, and 1.8 km3yr-1 of the surface water, respectively. The remaining 747 km3yr-1 freshwater requirement was unmet, or surface water was not available when and where it was needed in our simulation. Renewable and nonrenewable groundwater accounted for 607 and 182 km3yr-1 of the groundwater total, respectively. Second, we evaluated the water stress using our simulations and contrasted it with earlier global assessments based on empirical water scarcity indicators, namely, the Withdrawal to Availability ratio and the Falkenmark index (annual renewable water resources per capita). We found that inclusion of water infrastructures in our model diminished water stress in some parts of the world, on

  5. Dosimetric measurements of an 192Ir HDR source with a diamond detector

    Rustgi, Surendra N.

    1996-01-01

    Purpose: To study the feasibility of using a diamond detector for the dosimetry of a high dose rate (HDR) 192 Ir source and to compare the measurement results with published data and calculations from a commercial treatment planning system. Materials and methods: The sensitive volume of the diamond detector consists of a disk of 0.26 mm thickness and 3 mm diameter. The detector was applied an external bias of +100 V and was preirradiated to a dose of 500 cGy to stabilize its response. The 192 Ir source from the Nucletron microSelectron unit has an active diameter of 0.6 mm and a length of 3.5 mm. Photon fluence anisotropy factors in air were measured at distances of 5 and 10 cm from two sources and compared with TLD measurements. Dose profiles and isodose distributions were measured at several distances from the source and compared with calculations from a Nucletron treatment planning system. These dose calculations in water use a point source approximation with the anisotropy factors independent of the radial distance from the source. Results: The photon fluence around the 192 Ir HDR source, measured with a diamond detector at distances of 5 and 10 cm from the source, is very anisotropic. Compared to the source transverse direction, the photon fluence intensity along the source axis reduces to approximately 60%. Measurements performed on two sources indicate that the photon anisotropy does not change with distance in air. Within experimental uncertainty, similar results were obtained with TLD rods and are in excellent agreement with published anisotropy factors 1 . Dose profiles, measured with the diamond detector in a water phantom, at distances of 1,2,3 and 5 cm from the source, are found to be in excellent agreement with the Nucletron planning system calculations. Similar excellent agreement is observed between the measured and calculated isodose curves in planes parallel to the source plane. Conclusion: The diamond detector has been demonstrated to be suitable

  6. Measurements of bremsstrahlung spectra of Lanzhou ECR Ion Source No. 3 (LECR3)

    Zhao, H.Y.; Zhao, H.W.; Ma, X.W.; Zhang, S.F.; Feng, W.T.; Zhu, X.L.; Zhang, Z.M.; He, W.; Sun, L.T.; Feng, Y.C.; Cao, Y.; Li, J.Y.; Li, X.X.; Wang, H.; Ma, B.H.

    2006-01-01

    In order to diagnose the electron cyclotron resonance (ECR) plasma, electron bremsstrahlung spectra were measured by a HPGe detector on Lanzhou ECR Ion Source No. 3 at IMP. The ion source was operated with argon under various working conditions, including different microwave power, mixing gas, extraction high voltage (HV), and so on. Some of the measured spectra are presented in this article. The dependence of energetic electron population on mixing gas and extraction HV is also described. Additionally, we are looking forward to further measurements on SECRAL (Superconducting ECR Ion Source with Advanced design at Lanzhou)

  7. Experience and problems of the automated measuring and sorting of sealed radiation sources

    Shmidt, G.

    1979-01-01

    It has been shown that with the help of a serial device for samples changing and a mini-computer with a suitable software it is possible to organize the radioactivity measuring and sorting of sealed gamma-sources with activity in the microcuri region. Application of the computer permits to rise accuracy of the data on the radiation sources radioactivity, sorted according to the preset activity level groups and, in the casa of necessity, to perform the activity measurements with lower error. The method listed, gives the working-time economy of nearly 4 hours in measuring and sorting of some 500 sealed radiation sources [ru

  8. Source attribution and interannual variability of Arctic pollution in spring constrained by aircraft (ARCTAS, ARCPAC and satellite (AIRS observations of carbon monoxide

    J. A. Fisher

    2010-02-01

    Full Text Available We use aircraft observations of carbon monoxide (CO from the NASA ARCTAS and NOAA ARCPAC campaigns in April 2008 together with multiyear (2003–2008 CO satellite data from the AIRS instrument and a global chemical transport model (GEOS-Chem to better understand the sources, transport, and interannual variability of pollution in the Arctic in spring. Model simulation of the aircraft data gives best estimates of CO emissions in April 2008 of 26 Tg month−1 for Asian anthropogenic, 9.4 for European anthropogenic, 4.1 for North American anthropogenic, 15 for Russian biomass burning (anomalously large that year, and 23 for Southeast Asian biomass burning. We find that Asian anthropogenic emissions are the dominant source of Arctic CO pollution everywhere except in surface air where European anthropogenic emissions are of similar importance. Russian biomass burning makes little contribution to mean CO (reflecting the long CO lifetime but makes a large contribution to CO variability in the form of combustion plumes. Analysis of two pollution events sampled by the aircraft demonstrates that AIRS can successfully observe pollution transport to the Arctic in the mid-troposphere. The 2003–2008 record of CO from AIRS shows that interannual variability averaged over the Arctic cap is very small. AIRS CO columns over Alaska are highly correlated with the Ocean Niño Index, suggesting a link between El Niño and Asian pollution transport to the Arctic. AIRS shows lower-than-average CO columns over Alaska during April 2008, despite the Russian fires, due to a weakened Aleutian Low hindering transport from Asia and associated with the moderate 2007–2008 La Niña. This suggests that Asian pollution influence over the Arctic may be particularly large under strong El Niño conditions.

  9. Distributed 3D Source Localization from 2D DOA Measurements Using Multiple Linear Arrays

    Antonio Canclini

    2017-01-01

    Full Text Available This manuscript addresses the problem of 3D source localization from direction of arrivals (DOAs in wireless acoustic sensor networks. In this context, multiple sensors measure the DOA of the source, and a central node combines the measurements to yield the source location estimate. Traditional approaches require 3D DOA measurements; that is, each sensor estimates the azimuth and elevation of the source by means of a microphone array, typically in a planar or spherical configuration. The proposed methodology aims at reducing the hardware and computational costs by combining measurements related to 2D DOAs estimated from linear arrays arbitrarily displaced in the 3D space. Each sensor measures the DOA in the plane containing the array and the source. Measurements are then translated into an equivalent planar geometry, in which a set of coplanar equivalent arrays observe the source preserving the original DOAs. This formulation is exploited to define a cost function, whose minimization leads to the source location estimation. An extensive simulation campaign validates the proposed approach and compares its accuracy with state-of-the-art methodologies.

  10. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-07

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients' CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  11. A measurement-based generalized source model for Monte Carlo dose simulations of CT scans

    Ming, Xin; Feng, Yuanming; Liu, Ransheng; Yang, Chengwen; Zhou, Li; Zhai, Hezheng; Deng, Jun

    2017-03-01

    The goal of this study is to develop a generalized source model for accurate Monte Carlo dose simulations of CT scans based solely on the measurement data without a priori knowledge of scanner specifications. The proposed generalized source model consists of an extended circular source located at x-ray target level with its energy spectrum, source distribution and fluence distribution derived from a set of measurement data conveniently available in the clinic. Specifically, the central axis percent depth dose (PDD) curves measured in water and the cone output factors measured in air were used to derive the energy spectrum and the source distribution respectively with a Levenberg-Marquardt algorithm. The in-air film measurement of fan-beam dose profiles at fixed gantry was back-projected to generate the fluence distribution of the source model. A benchmarked Monte Carlo user code was used to simulate the dose distributions in water with the developed source model as beam input. The feasibility and accuracy of the proposed source model was tested on a GE LightSpeed and a Philips Brilliance Big Bore multi-detector CT (MDCT) scanners available in our clinic. In general, the Monte Carlo simulations of the PDDs in water and dose profiles along lateral and longitudinal directions agreed with the measurements within 4%/1 mm for both CT scanners. The absolute dose comparison using two CTDI phantoms (16 cm and 32 cm in diameters) indicated a better than 5% agreement between the Monte Carlo-simulated and the ion chamber-measured doses at a variety of locations for the two scanners. Overall, this study demonstrated that a generalized source model can be constructed based only on a set of measurement data and used for accurate Monte Carlo dose simulations of patients’ CT scans, which would facilitate patient-specific CT organ dose estimation and cancer risk management in the diagnostic and therapeutic radiology.

  12. Directivity of Spherical Polyhedron Sound Source Used in Near-Field HRTF Measurements

    Yu Guang-Zheng; Xie Bo-Sun; Rao Dan

    2010-01-01

    The omnidirectional character is one of important requirements for the sound source used in near-field head-related transfer function (HRTF) measurements. Based on the analysis on the radiation sound pressure and directivity character of various spherical polyhedron sound sources, a spherical dodecahedral sound source with radius of 0.035m is proposed and manufactured. Theoretical and measured results indicate that the sound source is approximately omnidirectional below the frequency of 8 kHz. In addition, the sound source has reasonable magnitude response from 350Hz to 20kHz and linear phase characteristics. Therefore, it is suitable for the near-field HRTF measurements. (fundamental areas of phenomenology(including applications))

  13. Radio measurements in the fields of gamma-ray sources. Pt. 1

    Sieber, W.; Schlickeiser, R.

    1982-01-01

    The γ-ray source CG 195+04 has been searched for radio counterparts at wavelengths between 2.8 cm and 18 cm with the 100-m telescope of the Max-Planck-Institut fuer Radioastronomie, Bonn. We have detected a number of sources and measured their spectra. Our positions may form the basis for future surveys in other frequency ranges. Different physical emission models suggest compactness of the γ-ray source. (orig.)

  14. THE Q/U IMAGING EXPERIMENT: POLARIZATION MEASUREMENTS OF RADIO SOURCES AT 43 AND 95 GHz

    Huffenberger, K. M. [Department of Physics, Florida State University, P.O. Box 3064350, Tallahassee, FL 32306-4350 (United States); Araujo, D.; Zwart, J. T. L. [Department of Physics and Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Bischoff, C.; Buder, I. [Kavli Institute for Cosmological Physics, Department of Physics, Enrico Fermi Institute, The University of Chicago, Chicago, IL 60637 (United States); Chinone, Y.; Hasegawa, M. [High Energy Accelerator Research Organization (KEK), 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Cleary, K. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, 1200 E. California Blvd M/C 249-17, Pasadena, CA 91125 (United States); Kusaka, A. [Physics Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Monsalve, R. [School of Earth and Space Exploration, Arizona State University, 781 E. Terrace Road, Tempe, AZ 85287 (United States); Næss, S. K. [Department of Astrophysics, University of Oxford, Keble Road, Oxford, OX1 3RH (United Kingdom); Newburgh, L. B. [Dunlap Institute, University of Toronto, 50 St. George Street, Toronto, ON M5S 3H4 (Canada); Reeves, R. [CePIA, Departamento de Astronomía, Universidad de Concepción (Chile); Ruud, T. M.; Eriksen, H. K. [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Wehus, I. K.; Gaier, T. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Dickinson, C. [Jodrell Bank Centre for Astrophysics, Alan Turing Building, School of Physics and Astronomy, The University of Manchester, Oxford Road, Manchester M13 9PL (United Kingdom); Gundersen, J. O., E-mail: huffenbe@physics.fsu.edu [Department of Physics, University of Miami, 1320 Campo Sano Drive, Coral Gables, FL 33146 (United States); Collaboration: QUIET Collaboration; and others

    2015-06-10

    We present polarization measurements of extragalactic radio sources observed during the cosmic microwave background polarization survey of the Q/U Imaging Experiment (QUIET), operating at 43 GHz (Q-band) and 95 GHz (W-band). We examine sources selected at 20 GHz from the public, >40 mJy catalog of the Australia Telescope (AT20G) survey. There are ∼480 such sources within QUIET’s four low-foreground survey patches, including the nearby radio galaxies Centaurus A and Pictor A. The median error on our polarized flux density measurements is 30–40 mJy per Stokes parameter. At signal-to-noise ratio > 3 significance, we detect linear polarization for seven sources in Q-band and six in W-band; only 1.3 ± 1.1 detections per frequency band are expected by chance. For sources without a detection of polarized emission, we find that half of the sources have polarization amplitudes below 90 mJy (Q-band) and 106 mJy (W-band), at 95% confidence. Finally, we compare our polarization measurements to intensity and polarization measurements of the same sources from the literature. For the four sources with WMAP and Planck intensity measurements >1 Jy, the polarization fractions are above 1% in both QUIET bands. At high significance, we compute polarization fractions as much as 10%–20% for some sources, but the effects of source variability may cut that level in half for contemporaneous comparisons. Our results indicate that simple models—ones that scale a fixed polarization fraction with frequency—are inadequate to model the behavior of these sources and their contributions to polarization maps.

  15. Complementarity between innovation knowledge sources: Does the innovation performance measure matter?

    Ana Mª Serrano-Bedia

    2018-01-01

    Full Text Available We analyse complementarity between different knowledge sources (internal, external and/or cooperation employing a wide range of innovation performance measures (product, process, organizational, and commercial. The empirical study uses 2014 Spanish CIS data and studies complementarities by performing conditional complementarity/substitutability tests. The results show evidence of conditional complementarity in product innovation performance between external and internal knowledge sources in absence of cooperation and of conditional substitute relationship between external and cooperation knowledge sources in presence of internal source. In product and process innovation performance we found a conditional substitute relationship between internal and cooperation sources when external source is used and not used, respectively. This relationship turns to conditional complementarity in organisational innovation in absence of external knowledge source. Therefore, when designing innovation strategy, managers must consider their objectives on a priority basis, since not all the strategies have the same effects on innovation performance.

  16. Measurement-device-independent quantum key distribution with correlated source-light-intensity errors

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2018-04-01

    We present an analysis for measurement-device-independent quantum key distribution with correlated source-light-intensity errors. Numerical results show that the results here can greatly improve the key rate especially with large intensity fluctuations and channel attenuation compared with prior results if the intensity fluctuations of different sources are correlated.

  17. AcquisitionFootprintAttenuationDrivenbySeismicAttributes

    Cuellar-Urbano Mayra

    2014-04-01

    Full Text Available Acquisition footprint, one of the major problems that PEMEX faces in seismic imaging, is noise highly correlated to the geometric array of sources and receivers used for onshore and offshore seismic acquisitions. It prevails in spite of measures taken during acquisition and data processing. This pattern, throughout the image, is easily confused with geological features and misguides seismic attribute computation. In this work, we use seismic data from PEMEX Exploración y Producción to show the conditioning process for removing random and coherent noise using linear filters. Geometric attributes used in a workflow were computed for obtaining an acquisition footprint noise model and adaptively subtract it from the seismic data.

  18. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  19. The optical properties of a double focusing bending magnet measured with a thin alpha source

    Armitage, S.A.; Eastham, D.A.

    1978-01-01

    The focusing properties of the 90 0 inflector magnet for the Nuclear Structure Facility (NSF) tandem at Daresbury Laboratory have been measured in the 2rho configuration using very thin alpha sources and a position-sensitive detector. (Auth.)

  20. Some problems of neutron source multiplication method for site measurement technology in nuclear critical safety

    Shi Yongqian; Zhu Qingfu; Hu Dingsheng; He Tao; Yao Shigui; Lin Shenghuo

    2004-01-01

    The paper gives experiment theory and experiment method of neutron source multiplication method for site measurement technology in the nuclear critical safety. The measured parameter by source multiplication method actually is a sub-critical with source neutron effective multiplication factor k s , but not the neutron effective multiplication factor k eff . The experiment research has been done on the uranium solution nuclear critical safety experiment assembly. The k s of different sub-criticality is measured by neutron source multiplication experiment method, and k eff of different sub-criticality, the reactivity coefficient of unit solution level, is first measured by period method, and then multiplied by difference of critical solution level and sub-critical solution level and obtained the reactivity of sub-critical solution level. The k eff finally can be extracted from reactivity formula. The effect on the nuclear critical safety and different between k eff and k s are discussed

  1. Spectral dependence of backscattering coefficient of mixed phase clouds over West Africa measured with two-wavelength Raman polarization lidar: Features attributed to ice-crystals corner reflection

    Veselovskii, I.; Goloub, P.; Podvin, T.; Tanre, D.; Ansmann, A.; Korenskiy, M.; Borovoi, A.; Hu, Q.; Whiteman, D. N.

    2017-11-01

    The existing models predict that corner reflection (CR) of laser radiation by simple ice crystals of perfect shape, such as hexagonal columns or plates, can provide a significant contribution to the ice cloud backscattering. However in real clouds the CR effect may be suppressed due to crystal deformation and surface roughness. In contrast to the extinction coefficient, which is spectrally independent, consideration of diffraction associated with CR results in a spectral dependence of the backscattering coefficient. Thus measuring the spectral dependence of the cloud backscattering coefficient, the contribution of CR can be identified. The paper presents the results of profiling of backscattering coefficient (β) and particle depolarization ratio (δ) of ice and mixed-phase clouds over West Africa by means of a two-wavelength polarization Mie-Raman lidar operated at 355 nm and 532 nm during the SHADOW field campaign. The lidar observations were performed at a slant angle of 43 degree off zenith, thus CR from both randomly oriented crystals and oriented plates could be analyzed. For the most of the observations the cloud backscatter color ratio β355/β532 was close to 1.0, and no spectral features that might indicate the presence of CR of randomly oriented crystals were revealed. Still, in two measurement sessions we observed an increase of backscatter color ratio to a value of nearly 1.3 simultaneously with a decrease of the spectral depolarization ratio δ355/δ532 ratio from 1.0 to 0.8 inside the layers containing precipitating ice crystals. We attribute these changes in optical properties to corner reflections by horizontally oriented ice plates.

  2. Finite element approximation for time-dependent diffusion with measure-valued source

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  3. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd source

    Sadeghi, Mahdi; Hosseini, Hamed; Raisali, Gholamreza

    2008-01-01

    Full text: The use of 103 Pd seed sources for permanent prostate implantation has become a popular brachytherapy application. As recommended by AAPM the dosimetric characteristics of the new source must be determined using experimental and Monte Carlo simulations, before its use in clinical applications thus The goal of this report is the experimental and theoretical determination of the dosimetric characteristics of this source following the recommendations in the AAPM TG-43U1 protocol. Figure 1 shows the geometry of the IRA- 103 Pd source. The source consists of a cylindrical silver core, 0.3 cm long x 0.05 cm in diameter, onto which 0.5 nm layer of 103 Pd has been uniformly adsorbed. The effective active length of source is 0.3 cm and the silver core encapsulated inside a hollow titanium tube with 0.45 cm long, 0.07 cm and 0.08 inner and outer diameters and two caps. The Monte Carlo N-Particle (MCNP) code, version 4C, was used to determine the relevant dosimetric parameters of the source. The geometry of the Monte Carlo simulation performed in this study consisted of a sphere with 30 cm diameter. Dose distributions around this source were measured in two Perspex phantom using enough TLD chips. For these measurements, slabs of Perspex material were machined to accommodate the source and TLD chips. A value of 0.67± 1% cGy.h -1 .U -1 for, Λ, was calculated as the ratio of d(r 0 ,θ 0 ) and s K , that may be compared with Λ values obtained for 103 Pd sources. Result of calculations and measurements values of dosimetric parameters of the source including radial dose function, g(r), and anisotropy function, F(r,θ), has been shown in separate figures. The radial dose function, g(r), for the IRA- 103 Pd source and other 103 Pd sources is included in Fig. 2. Comparison between measured and Monte Carlo simulated dose function, g(r), and anisotropy function, F(r,θ), of this source demonstrated that they are in good agreement with each other and The value of Λ is

  4. Implementation of 252Cf-source-driven power spectrum density measurement system

    Ren Yong; Wei Biao; Feng Peng; Li Jiansheng; Ye Cenming

    2012-01-01

    The principle of 252 Cf-source-driven power spectrum density measurement method is introduced. A measurement system and platform is realized accordingly, which is a combination of hardware and software, for measuring nuclear parameters. The detection method of neutron pulses based on an ultra-high-speed data acquisition card (three channels, 1 GHz sampling rate, 1 ns synchronization) is described, and the data processing process and the power spectrum density algorithm on PC are designed. This 252 Cf-source-driven power spectrum density measurement system can effectively obtain the nuclear tag parameters of nuclear random processes, such as correlation function and power spectrum density. (authors)

  5. Response of a BGO detector to photon and neutron sources simulations and measurements

    Vincke, H H; Fabjan, Christian Wolfgang; Otto, T

    2002-01-01

    In this paper Monte Carlo simulations (FLUKA) and measurements of the response of a BGO detector are reported. %For the measurements different radioactive sources were used to irradiate the BGO crystal. For the measurements three low-energy photon emitters $\\left({}^{60}\\rm{Co},\\right.$ ${}^{54}\\rm{Mn},$ $\\left. {}^{137}\\rm{Cs}\\right)$ were used to irradiate the BGO from various distances and angles. The neutron response was measured with an Am--Be neutron source. Simulations of the experimental irradiations were carried out. Our study can also be considered as a benchmark for FLUKA in terms of its reliability to predict the detector response of a BGO scintillator.

  6. Sources

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  7. Regularity of the wear control of radioactive sources from the nuclear measurers

    Ferreira L, M.

    2006-01-01

    The control of radioactive sources in Brazil is regulated by the CNEN (National Comissao of Nuclear Energy). The Laboratory of Descontaminacao of the IPEN (Institute of Energy Y Nuclear Investigations) it offers to the companies that work with nuclear measurers, essays for control of the source wear according to the ISO 9978/1992 through the smear tests Y of leakage. The analyses are taken in alpha Y beta detectors of low bottom radiation with annual detection limits around 1 Bq. Certificates of the accepted analyses by the CNEN for sources that already passed its time of validity assured by the makers, but its continue operational are emitted. The smear test is repeated the whole year, while the leakage test repeats to every two years. A balance of the last two years of the activities of the laboratory shows the regularity of the clients Y the growth of companies specialized in radioprotection with official of radioprotection, credited by the regulatory authority that its act as intermediaries in the process, contacting the clients, gathering the samples next to the proprietors of sources Y hiring our services. Overalls, proves that the inspection activities by part of the regulatory authority are fulfil. In 2004, 192 sources were analyzed by the smear method Y 86 sources by leakage. In 2005, 232 sources were analyzed by the smear method Y 60 sources by leakage. All the leakage tests was made in sources of Americium of oneself Y only client that brings the sources so that they dismantle them to him in the Sources production laboratory of the IPEN. By the quantity Y age of the sources that were analyzed in those two years, it is proven that the number of sources without use conditions (total activity measured by the two added methods smaller than 180Bq) it doesn't arrive to 2%. (Author)

  8. Characterization of the γ background in epithermal neutron scattering measurements at pulsed neutron sources

    Pietropaolo, A.; Tardocchi, M.; Schooneveld, E.M.; Senesi, R.

    2006-01-01

    This paper reports the characterization of the different components of the γ background in epithermal neutron scattering experiments at pulsed neutron sources. The measurements were performed on the VESUVIO spectrometer at ISIS spallation neutron source. These measurements, carried out with a high purity germanium detector, aim to provide detailed information for the investigation of the effect of the γ energy discrimination on the signal-to-background ratio. It is shown that the γ background is produced by different sources that can be identified with their relative time structure and relative weight

  9. On-line measurement of microwave power in ECR ion source

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang; Li Xiaoyun

    2005-01-01

    It is a new technology to apply an ECR ion source to the neutron generator. Because of the structure limitation, working state of the ECR ion source could not be judged by the color of gas discharging in discharge chamber. Therefore, it was hard to estimate if the ECR ion source was working properly in the neutron generator. The method to resolve the problem was described in this paper. The microwave power was measured on-line by a directional coupler and a small microwave power meter. The ion beam current could be educed from the measured incidence microwave power, and discharge state in discharge chamber could be determined. (authors)

  10. Methane source identification in Boston, Massachusetts using isotopic and ethane measurements

    Down, A.; Jackson, R. B.; Plata, D.; McKain, K.; Wofsy, S. C.; Rella, C.; Crosson, E.; Phillips, N. G.

    2012-12-01

    Methane has substantial greenhouse warming potential and is the principle component of natural gas. Fugitive natural gas emissions could be a significant source of methane to the atmosphere. However, the cumulative magnitude of natural gas leaks is not yet well constrained. We used a combination of point source measurements and ambient monitoring to characterize the methane sources in the Boston urban area. We developed distinct fingerprints for natural gas and multiple biogenic methane sources based on hydrocarbon concentration and isotopic composition. We combine these data with periodic measurements of atmospheric methane and ethane concentration to estimate the fractional contribution of natural gas and biogenic methane sources to the cumulative urban methane flux in Boston. These results are used to inform an inverse model of urban methane concentration and emissions.

  11. Brightness measurement of an electron impact gas ion source for proton beam writing applications

    Liu, N.; Santhana Raman, P. [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583 (Singapore); Xu, X.; Pang, R.; Kan, J. A. van, E-mail: phyjavk@nus.edu.sg [Centre for Ion Beam Applications, Department of Physics, National University of Singapore, Singapore 117542 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, Singapore 117583 (Singapore)

    2016-02-15

    We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

  12. Angular and mass resolved energy distribution measurements with a gallium liquid metal ion source

    Marriott, Philip

    1987-06-01

    Ionisation and energy broadening mechanisms relevant to liquid metal ion sources are discussed. A review of experimental results giving a picture of source operation and a discussion of the emission mechanisms thought to occur for the ionic species and droplets emitted is presented. Further work is suggested by this review and an analysis system for angular and mass resolved energy distribution measurements of liquid metal ion source beams has been constructed. The energy analyser has been calibrated and a series of measurements, both on and off the beam axis, of 69 Ga + , Ga ++ and Ga 2 + ions emitted at various currents from a gallium source has been performed. A comparison is made between these results and published work where possible, and the results are discussed with the aim of determining the emission and energy spread mechanisms operating in the gallium liquid metal ion source. (author)

  13. Measurement of the activity of an artificial neutrino source based on 37Ar

    Abdurashitov, D. N.; Veretenkin, E. P.; Gavrin, V. N.; Gorbachev, V. V.; Ibragimova, T. V.; Kalikhov, A. V.; Mirmov, I. N.; Shikhin, A. A.; Yants, V. E.; Barsanov, V. I.; Dzhanelidze, A. A.; Zlokazov, S. B.; Markov, S. Yu.; Shakirov, Z. N.; Cleveland, B. T.

    2007-01-01

    The activity of an artificial neutrino source based on 37 Ar was measured by a specially developed method of directly counting 37 Ar decays in a proportional counter. This source was used to irradiate the target of the SAGE radiochemical gallium-germanium neutrino telescope at the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences, Moscow), whereupon the measurements were performed at the Institute of Reactor Materials (Zarechny, Sverdlovsk oblast, Russia). The method used to prepare gaseous samples for measurements in proportional counters and the counting procedure are described. The measured activity of the 37 Ar neutrino source is 405.1 ± 3.7 kCi (corrected for decays that occurred within the period between the instant of activity measurement and the commencement of the irradiation of Ga target at 04:00 Moscow time, 30.04.2004)

  14. Flux density measurements of radio sources at 2.14 millimeter wavelength

    Cogdell, J.R.; Davis, J.H.; Ulrich, B.T.; Wills, B.J.

    1975-01-01

    Flux densities of galactic and extragalactic sources, and planetary temperatures, have been measured at 2.14 mm wavelength (140 GHz). Results are presented for OJ 287; the galactic sources DR 21, W3, and Orion A; the extragalactic sources PKS 0106plus-or-minus01, 3C 84, 3C 120, BL Lac, 3C 216, 3C 273, 3C 279, and NGC 4151; and the Sun, Venus, Mars, and Jupiter. Also presented is the first measurement of the 2.14-mm temperature of Uranus. The spectra of some of these sources are discussed. The flux density scale was calibrated absolutely. The measurements were made with a new continuum receiver on the 4.88-m radio telescope of The University of Texas

  15. Interferometry with flexible point source array for measuring complex freeform surface and its design algorithm

    Li, Jia; Shen, Hua; Zhu, Rihong; Gao, Jinming; Sun, Yue; Wang, Jinsong; Li, Bo

    2018-06-01

    The precision of the measurements of aspheric and freeform surfaces remains the primary factor restrict their manufacture and application. One effective means of measuring such surfaces involves using reference or probe beams with angle modulation, such as tilted-wave-interferometer (TWI). It is necessary to improve the measurement efficiency by obtaining the optimum point source array for different pieces before TWI measurements. For purpose of forming a point source array based on the gradients of different surfaces under test, we established a mathematical model describing the relationship between the point source array and the test surface. However, the optimal point sources are irregularly distributed. In order to achieve a flexible point source array according to the gradient of test surface, a novel interference setup using fiber array is proposed in which every point source can be independently controlled on and off. Simulations and the actual measurement examples of two different surfaces are given in this paper to verify the mathematical model. Finally, we performed an experiment of testing an off-axis ellipsoidal surface that proved the validity of the proposed interference system.

  16. A method for measuring power signal background and source strength in a fission reactor

    Baers, B.; Kall, L.; Visuri, P.

    1977-01-01

    Theory and experimental verification of a novel method for measuring power signal bias and source strength in a fission reactor are reported. A minicomputer was applied in the measurements. The method is an extension of the inverse kinetics method presented by Mogilner et al. (Auth.)

  17. A method for the coherence measurement of the supercontinuum source using Michelson interferometer

    Semenova, V A; Tsypkin, A V; Putilin, S E; Bespalov, V G

    2014-01-01

    Coherent properties of supercontinuum sources are highly significant for various applications, including low-coherence interferometry and optical frequency metrology. We propose a fast method for the spatial and temporal self-coherence of the SC measurement using Michelson interferometer without a mirror movement. Furthermore, we present self-coherence measurements of the supercontinuum, generated in microstructured fiber at 780 nm.

  18. Statistical measurement of the gamma-ray source-count distribution as a function of energy

    Zechlin, H.-S.; Cuoco, A.; Donato, F.; Fornengo, N.; Regis, M.

    2017-01-01

    Photon counts statistics have recently been proven to provide a sensitive observable for characterizing gamma-ray source populations and for measuring the composition of the gamma-ray sky. In this work, we generalize the use of the standard 1-point probability distribution function (1pPDF) to decompose the high-latitude gamma-ray emission observed with Fermi-LAT into: (i) point-source contributions, (ii) the Galactic foreground contribution, and (iii) a diffuse isotropic background contribution. We analyze gamma-ray data in five adjacent energy bands between 1 and 171 GeV. We measure the source-count distribution dN/dS as a function of energy, and demonstrate that our results extend current measurements from source catalogs to the regime of so far undetected sources. Our method improves the sensitivity for resolving point-source populations by about one order of magnitude in flux. The dN/dS distribution as a function of flux is found to be compatible with a broken power law. We derive upper limits on further possible breaks as well as the angular power of unresolved sources. We discuss the composition of the gamma-ray sky and capabilities of the 1pPDF method.

  19. Development of source range measurement instrument in Xi'an pulsed reactor

    Wang Li

    2002-01-01

    Source range measurement instrument in Xi'an pulsed reactor is key equipment of low-side measuring in source range. At the same time, it is also weighty component of out-of-pile neutron-flux level observation system. The authors have done some researching and renovating based on the similar type devices used in nuclear reactor to improve the meter sensitivity, measuring range, noise proof features, reliability in running and maintainability which belong to the main performance index of the instrument. The design ideas, configurations, working principle, performance indexes, technique features and effect in utilizing are introduced briefly

  20. Radiation measurement practice for understanding statistical fluctuation of radiation count using natural radiation sources

    Kawano, Takao

    2014-01-01

    It is known that radiation is detected at random and the radiation counts fluctuate statistically. In the present study, a radiation measurement experiment was performed to understand the randomness and statistical fluctuation of radiation counts. In the measurement, three natural radiation sources were used. The sources were fabricated from potassium chloride chemicals, chemical fertilizers and kelps. These materials contain naturally occurring potassium-40 that is a radionuclide. From high schools, junior high schools and elementary schools, nine teachers participated to the radiation measurement experiment. Each participant measured the 1-min integration counts of radiation five times using GM survey meters, and 45 sets of data were obtained for the respective natural radiation sources. It was found that the frequency of occurrence of radiation counts was distributed according to a Gaussian distribution curve, although the obtained 45 data sets of radiation counts superficially looked to be fluctuating meaninglessly. (author)

  1. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source.

    Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W

    2012-06-01

    The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

  2. Stability check source measurements with a secondary standard dosimeter in SSDL-Pakistan

    Salman, S.; Mahmoud, K.; Orfi, S.D.

    1988-01-01

    The stability check source is an integral part of a Secondary Standard Dosimetry System. The purpose of the stability check source is to confirm that the overall response of the dosimeter has not changed significantly since the instrument was calibrated. In case any change in the sensitivity of the ionization chamber or measuring assembly occurs the same is reflected in the reference check source measurements. Stability check source measurements are taken in a Primary Standard Dosimetry Laboratory (PSDL) at the time of calibration of secondary standard dosimeter and mean time (in seconds) to the reference setting of 50 scale divisions with ambient conditions of air at 20 deg. C, 101.3 kPa and 50% RH is quoted in a calibration certificate. This quoted stability check source time figure is the basis for future confirmation of overall response of the secondary standard dosimeter system. This note presents the results of stability check source measurements carried out in SSDL Pakistan over a period of five years

  3. Methods and apparatus for safely handling radioactive sources in measuring-while-drilling tools

    Wraight, P.D.

    1989-01-01

    This patent describes a method for removing a chemical radioactive source from a MWD tool which is coupled in a drill string supported by a drilling rig while a borehole is drilled and includes logging means for measuring formation characteristics in response to irradiation of the adjacent formations by the radioactive source during the drilling operation. The steps of the method are: halting the drilling operation and then removing the drill string from the borehole for moving the MWD tool to a work station at the surface where the source is at a safe working distance from the drilling rig and will be accessible by way of one end of the MWD tool; positioning a radiation shield at a location adjacent to the one end of the MWD tool where the shield is ready for receiving the source as it is moved away from the other end of the MWD tool and then moving the source away from the other end of the MWD tool for enclosing the source within the shield; and once the source is enclosed within the shield; removing the shield together with the enclosed source from the MWD tool for transferring the enclosed source to another work station

  4. Single-source gamma radiation procedures for improved calibration and measurements in porous media

    Oostrom, M.; Hofstee, C.; Dane, H.; Lenhard, R.J.

    1998-01-01

    When dual-energy gamma radiation systems are employed for measurements in porous media, count rates from both sources are often used to compute parameter values. However, for several applications, the count rates of just one source are insufficient. These applications include the determination of volumetric liquid content values in two-liquid systems and salt concentration values in water-saturated porous media. Single-energy gamma radiation procedures for three applications are described in this paper. Through an error analysis, single-source procedures are shown to reduce the probable error in the determinations considerably. Example calculations and simple column experiments were conducted for each application to compare the performance of the new single-source and standard dual-source methods. In all cases, the single-source methods provided more reliable data than the traditional dual-source methods. In addition, a single-source calibration procedure is proposed to determine incident count rates indirectly. This procedure, which requires packing under saturated conditions, can be used in all single- and dual-source applications and yields accurate porosity and dry bulk density values

  5. Unaccounted source of systematic errors in measurements of the Newtonian gravitational constant G

    DeSalvo, Riccardo

    2015-01-01

    Many precision measurements of G have produced a spread of results incompatible with measurement errors. Clearly an unknown source of systematic errors is at work. It is proposed here that most of the discrepancies derive from subtle deviations from Hooke's law, caused by avalanches of entangled dislocations. The idea is supported by deviations from linearity reported by experimenters measuring G, similarly to what is observed, on a larger scale, in low-frequency spring oscillators. Some mitigating experimental apparatus modifications are suggested. - Highlights: • Source of discrepancies on universal gravitational constant G measurements. • Collective motion of dislocations results in breakdown of Hook's law. • Self-organized criticality produce non-predictive shifts of equilibrium point. • New dissipation mechanism different from loss angle and viscous models is necessary. • Mitigation measures proposed may bring coherence to the measurements of G

  6. Ground motion measurements at the LBL Light Source site, the Bevatron and at SLAC

    Green, M.A.; Majer, E.I.; More, V.D.; O'Connell, D.R.; Shilling, R.C.

    1986-12-01

    This report describes the technique for measuring ground motion at the site of the 1.0 to 2.0 GeV Synchrotron Radiation Facility which was known as the Advanced Light Source (in 1983 when the measurements were taken). The results of ground motion measurements at the Light Source site at Building 6 at LBL are presented. As comparison, ground motion measurements were made at the Byerly Tunnel, the Bevatron, Blackberry Canyon, and SLAC at the Spear Ring. Ground Motion at the Light Source site was measured in a band from 4 to 100 Hz. The measured noise is primarily local in origin and is not easily transported through LBL soils. The background ground motion is for the most part less than 0.1 microns. Localized truck traffic near Building 6 and the operation of the cranes in the building can result in local ground motions of a micron or more for short periods of time. The background motion at Building 6 is between 1 and 2 orders of magnitude higher than ground motion in a quiet seismic tunnel, which is representative of quiet sites worldwide. The magnitude of the ground motions at SLAC and the Bevatron are comparable to ground motions measured at the Building 6 Light Source site. However, the frequency signature of each site is very different

  7. Investigation of gasoline distributions within petrol stations: spatial and seasonal concentrations, sources, mitigation measures, and occupationally exposed symptoms.

    Sairat, Theerapong; Homwuttiwong, Sahalaph; Homwutthiwong, Kritsana; Ongwandee, Maneerat

    2015-09-01

    We measured levels of VOCs and determined the distributions of benzene concentrations over the area of two petrol stations in all three seasons. Using the concentrations and sampling positions, we created isoconcentration contour maps. The average concentrations ranged 18-1288 μg m(-3) for benzene and 12-81 μg m(-3) for toluene. The contour maps indicate that high-level contours of benzene were found not only at the fuel dispenser areas but also at the storage tank refilling points, open drainage areas where gasoline-polluted wastewater was flowing, and the auto service center located within the station area. An assessment of the benzene to toluene ratio contour plots implicates that airborne benzene and toluene near the fuel dispenser area were attributed to gasoline evaporation although one of the studied stations may be influenced by other VOC sources besides gasoline evaporation. Additionally, during the routine refilling of the underground fuel storage tanks by a tank truck, the ambient levels of benzene and toluene increased tremendously. The implementation of source control by replacing old dispensers with new fuel dispensers that have an efficient cutoff feature and increased delivery speed can reduce spatial benzene concentrations by 77%. Furthermore, a questionnaire survey among 63 service attendants in ten stations revealed that headache was the most reported health complaint with a response rate of 32%, followed by fatigue with 20%. These prominent symptoms could be related to an exposure to high benzene concentrations.

  8. Internal Combustion Engines as the Main Source of Ultrafine Particles in Residential Neighborhoods: Field Measurements in the Czech Republic

    Jitka Stolcpartova

    2015-11-01

    Full Text Available Ultrafine particles (UFP, diameter < 100 nm exposure has already been associated with adverse effects on human health. Spatial distribution of UFP is non-uniform; they concentrate in the vicinity of the source, e.g. traffic, because of their short lifespan. This work investigates spatial distribution of UFP in three areas in the Czech Republic with different traffic load: High traffic (Prague neighborhood—Sporilov, commuter road vicinity (Libeznice, and a small city with only local traffic (Celakovice. Size-resolved measurements of particles in the 5–500 nm range were taken with a particle classifier mounted, along with batteries, GPS and other accessories, on a handcart and pushed around the areas, making one-minute or longer stops at places of interest. Concentrations along main roads were elevated in comparison with places farther from the road; this pattern was observed in all sites, while particle number distributions both close and away from main roads had similar patterns. The absence of larger particles, the relative absence of higher concentrations of particles away from the main roads, and similar number distributions suggest that high particle number concentrations cannot be readily attributed to sources other than internal combustion engines in vehicles and mobile machinery (i.e., mowers and construction machines.

  9. On-line measurement of the microwave power in ECR ion source

    Zhou Changgeng; Kang Wu; Hu Yonghong; Li Yan; Lou Benchao; Zu Xiulan; Xiong Riheng; Chen Junguang

    2005-01-01

    It is a new technology that ECR ion source is applied in the neutron generator. Because of effect of the structure, working state of ECR ion source could not be judged by the color of gas discharging in discharging chamber as doing in high frequency ion source. Therefore, state adjusting of ECR ion source was difficult in running of the neutron generator. The method to resolve the question is described in this paper. The micro-wave power was measured in case of running by using the method of directional coupler adding small microwave power meter. Because both were in the direct proportion, the ion beam current could be educed from microwave incidence power measured, and discharge state in discharge chamber could be judged. Finally, the neutron generator might be operated in best running state. (authors)

  10. Unaccounted source of systematic errors in measurements of the Newtonian gravitational constant G

    DeSalvo, Riccardo

    2015-06-01

    Many precision measurements of G have produced a spread of results incompatible with measurement errors. Clearly an unknown source of systematic errors is at work. It is proposed here that most of the discrepancies derive from subtle deviations from Hooke's law, caused by avalanches of entangled dislocations. The idea is supported by deviations from linearity reported by experimenters measuring G, similarly to what is observed, on a larger scale, in low-frequency spring oscillators. Some mitigating experimental apparatus modifications are suggested.

  11. Measuring Prosocial Tendencies in Germany: Sources of Validity and Reliablity of the Revised Prosocial Tendency Measure

    Rodrigues, Johannes; Ulrich, Natalie; Mussel, Patrick; Carlo, Gustavo; Hewig, Johannes

    2017-01-01

    The prosocial tendencies measure (PTM; Carlo and Randall, 2002) is a widely used measurement for prosocial tendencies in English speaking participants. This instrument distinguishes between six different types of prosocial tendencies that partly share some common basis, but also can be opposed to each other. To examine these constructs in Germany, a study with 1067 participants was conducted. The study investigated the structure of this German version of the PTM-R via exploratory factor analysis, confirmatory factor analysis, correlations with similar constructs in subsamples as well as via measurement invariance test concerning the original English version. The German translation showed a similar factor structure to the English version in exploratory factor analysis and in confirmatory factor analysis. Measurement invariance was found between the English and German language versions of the PTM and support for the proposed six-factor structure (altruistic, anonymous, compliant, dire, emotional and public prosocial behavior) was also found in confirmatory factor analysis. Furthermore, the expected interrelations of these factors of prosocial behavior tendencies were obtained. Finally, correlations of the prosocial behavior tendencies with validating constructs and behaviors were found. Thus, the findings stress the importance of seeing prosocial behavior not as a single dimension construct, but as a factored construct which now can also be assessed in German speaking participants. PMID:29270144

  12. A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method

    Mihalczo, J.T.; Ragan, G.E.; Blakeman, E.D.

    1988-01-01

    A portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with associated electronics that provide the signals to analog-to-digital (A/D) convertors) has been assembled to measure subcriticality by the /sup 252/Cf-source-driven neutron noise analysis method. The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcritical neutron multiplication factor of a configuration of fissile material requires measurement of the frequency-dependent cross-power spectral density (CPSD), G/sub 23/(ω), between a pair of detectors (Nos. 2 and 3) located in or near the fissile material and CPSDs G/sub 12/(ω) and G/sub 13/(ω) between these same detectors and a source of neutrons emanating from an ionization chamber (No. 1) containing /sup 252/Cf, also positioned in or near the fissile material. The auto-power spectral density (APSD), G/sub 11/(ω), of the source is also required. A particular ratio of spectral densities, G/sub 12//sup */G/sub 13//G/sub 11/G/sub 23/ (/sup */ denotes complex conjugation), is then formed. This ratio is related to the subcritical neutron multiplication factor and is independent of detector efficiencies

  13. A 6.13MeV gamma reference source, measurement of the emission rate

    Robert, Andre; Blondel, Maurice; Morel, Jean; Thomas, Claude.

    1977-08-01

    A 6.13MeV γ reference source has been produced by using 13 C(α, nγ) 16 O reaction occurring in an intimate 13 C and 238 Pu mixture. With two walls made leak proof this standard source is easy handled and convenient to the calibration of detectors. The 6.13MeV gamma ray is emitted without Doeppler effect, is measured with an uncertainty of 6% by three independent methods [fr

  14. Design of γ measurement system of neutron source strength standard with a manganese sulphate bath method

    Wang Xiaoqiong; Wang Pan; Chen Mingchi; Zhang Hui

    2010-01-01

    It mostly introduced the hardware and software design and test of Measurement System of Neutron Source Strength Standard with a Manganese Sulphate Bath Method. Hardware of system mainly contains six modules named detector, high voltage source, head amplifier, main amplifier, single channel pulse-amplitude analyzer and data acquisition system. The software program of system data acquisition is made up of four functional modules: user login, parameter setting, data collection, and data saving. (authors)

  15. Source profiles of volatile organic compounds (VOCs) measured in China: Part I

    Liu, Ying; Shao, Min; Fu, Linlin; Lu, Sihua; Zeng, Limin; Tang, Dagang

    The profiles of major volatile organic compound (VOC) sources in China, including vehicle exhaust, gasoline vapor, paint, asphalt, industrial and residential coal burning, biomass burning, and the petrochemical industry, were experimentally determined. Source samples were taken using a dilution chamber for mobile and stationary sources, biomass burning in an actual Chinese farmer's house, and ambient air in a petrochemical industrial area. The concentrations of 92 VOC species were quantified using canister sampling and a gas chromatography-flame ionization detection/mass spectrometry system, and VOC source profiles were developed for source apportionment of VOCs in the Pearl River Delta region. Based on the measurement of source profiles, possible tracers for various emission sources were identified; e.g., 2-methylpentane and 1,3-butadiene could be used as tracers for vehicle exhaust; the characteristic compounds of architectural coating were aromatics such as toluene and m, p-xylene; the light hydrocarbons, namely n-butane, trans-2-butene, and n-pentane, dominated the composition of gasoline vapor; and n-nonane, n-decane, and n-undecane were found to be typical of diesel vapor and asphalt application processes. As different emission sources are characterized by overlapping VOC species, the ratio of possible VOC tracers could be used to assess the contribution of various sources. The ratios between n-butane and isobutane, 1,3-butadiene and isoprene, and the ratios of aromatics (e.g., toluene to benzene and ethylbenzene to m, p-xylene) in the measured sources were compared.

  16. Source modelling of train noise - Literature review and some initial measurements

    Zhang Xuetao; Jonasson, Hans; Holmberg, Kjell

    2000-07-01

    A literature review of source modelling of railway noise is reported. Measurements on a special test rig at Surahammar and on the new railway line between Arlanda and Stockholm City are reported and analyzed. In the analysis the train is modelled as a number of point sources with or without directivity and each source is combined with analytical sound propagation theory to predict the sound propagation pattern best fitting the measured data. Wheel/rail rolling noise is considered to be the most important noise source. The rolling noise can be modelled as an array of moving point sources, which have a dipole-like horizontal directivity and some kind of vertical directivity. In general it is necessary to distribute the point sources on several heights. Based on our model analysis the source heights for the rolling noise should be below the wheel axles and the most important height is about a quarter of wheel diameter above the railheads. When train speeds are greater than 250 km/h aerodynamic noise will become important and even dominant. It may be important for low frequency components only if the train speed is less than 220 km/h. Little data are available for these cases. It is believed that aerodynamic noise has dipole-like directivity. Its spectrum depends on many factors: speed, railway system, type of train, bogies, wheels, pantograph, presence of barriers and even weather conditions. Other sources such as fans, engine, transmission and carriage bodies are at most second order noise sources, but for trains with a diesel locomotive engine the engine noise will be dominant if train speeds are less than about 100 km/h. The Nord 2000 comprehensive model for sound propagation outdoors, together with the source model that is based on the understandings above, can suitably handle the problems of railway noise propagation in one-third octave bands although there are still problems left to be solved.

  17. Broadband light source for fiber-optic measurement system in spaceborne applications

    Rößner, Max R.; Müller, Mathias S.; Buck, Thorbjörn C.; Koch, Alexander W.

    2012-01-01

    Measuring temperatures, mechanical loads and derived quantities precisely and reliably play an important role in spaceflight. With spacecraft becoming increasingly complex, upscaling of present telemetry techniques can become cumbersome. Additionally, there are entirely new sensory requirements, resulting from emerging technologies such as smart structures, active vibration damping and composite material health monitoring. It has been demonstrated in preceding studies that these measurements can be advantageously and efficiently carried out by means of fiber-optic systems. The most prominent fiber-optic strain and temperature sensor is the fiber Bragg grating. Typically, multiple fiber Bragg gratings are used to translate entire temperature and strain fields into an optical wavelength information. For the interrogation of these sensors, a broadband or scanning light source is required. Additional requirements with respect to the light source are high intensity and unpolarized illumination of the gratings. These constraints can be met by a light source that is based on amplified spontaneous emission in a rare-earth-doped fiber. In the presented work, a compact light source, adapted for measurement applications and targeted towards space applications, has been developed. The design of this light source is presented, as well as its implementation. The light source has been designed and tested for selected core aspects of space robustness and the results of these tests are summarized.

  18. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  19. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  20. Analysis of rod drop and pulsed source measurements of reactivity in the Winfrith SGHWR

    Brittain, I.

    1970-05-01

    Reactivity measurements by the rod-drop and pulsed source methods in the Winfrith SGHWR are seriously affected by spatial harmonics. A method of calculation is described which enables the spatial harmonics to be calculated in non-uniform cores in two or three dimensions, and thus allows a much more rigorous analysis of the experimental results than the usual point model. The method is used to analyse all the rod-drop measurements made during commissioning of the Winfrith SGHWR, and to comment on the results of pulsed source measurements. The reactivity worths of banks of ten and twelve shut-down tubes deduced from rod-drop and pulsed source experiments are in satisfactory agreement with each other and also with AIMAZ calculated values. The ability to calculate higher spatial harmonics in nonuniform cores is thought to be new, and may have a wider application to reactor kinetics through the method of Modal Analysis. (author)

  1. Measurement and simulation of the time-dependent behavior of the UMER source

    Haber, I.; Feldman, D.; Fiorito, R.; Friedman, A.; Grote, D.P.; Kishek, R.A.; Quinn, B.; Reiser, M.; Rodgers, J.; O'Shea, P.G.; Stratakis, D.; Tian, K.; Vay, J.-L.; Walter, M.

    2007-01-01

    Control of the time-dependent characteristics of the beam pulse, beginning when it is born from the source, is important for obtaining adequate beam intensity on a target. Recent experimental measurements combined with the new mesh-refinement capability in WARP have improved the understanding of time-dependent beam characteristics beginning at the source, as well as the predictive ability of the simulation codes. The University of Maryland Electron Ring (UMER), because of its ease of operation and flexible diagnostics has proved particularly useful for benchmarking WARP by comparing simulation to measurement. One source of significant agreement has been in the ability of three-dimensional WARP simulations to predict the onset of virtual cathode oscillations in the vicinity of the cathode grid in the UMER gun, and the subsequent measurement of the predicted oscillations

  2. Determination of delayed neutrons source in the frequency domain based on in-pile oscillation measurements

    Yedvab, Y.; Reiss, I.; Bettan, M.; Harari, R.; Grober, A.; Ettedgui, H.; Caspi, E. N.

    2006-01-01

    A method for determining delayed neutrons source in the frequency domain based on measuring power oscillations in a non-critical reactor is presented. This method is unique in the sense that the delayed neutrons source is derived from the dynamic behavior of the reactor, which serves as the measurement system. An algorithm for analyzing power oscillation measurements was formulated, which avoids the need for a multi-parameter non-linear fit process used by other methods. Using this algorithm results of two sets of measurements performed in IRR-I and IRR-II (Israeli Research Reactors I and II) are presented. The agreement between measured values from both reactors and calculated values based on Keepin (and JENDL-3.3) group parameters is very good. (authors)

  3. Corrections to air kerma rate measurements of 125I brachytherapy sources to free space conditions

    Shipley, D.R.; Duane, S.

    1994-05-01

    Air kerma rate measurements have been made between 40 cm and 100 cm from one of a set of 125 I reference sources within the facilities of Amersham International plc. Monte Carlo techniques have been used to calculate the air kerma rate components over the same range of distances from this source. After comparing the calculated data with measurements, the compliance of the data with the inverse square law was investigated, and corrections were derived to obtain the air kerma rate at 1 m in free space from each source. Simulations of the experimental setup with an isotropic monoenergetic point source close to the effective energy of 125 I were found to reproduce the air kerma rate measurements reasonably accurately, and indicated that the contribution due to scattered photons was significant. The overall correction (which is defined as the product of individual corrections for chamber size effect, air attenuation and radiation scatter) required to the inverse square law to obtain the air kerma rate at 1 m in free space was found to be 0.981, 0.984 and 0.980, respectively, for air kerma rate measurements at 40 cm, 60 cm and 100 cm from the 125 I reference source. The total uncertainty in these corrections was estimated to be 0.88% at the 1σ level. (author)

  4. Neutron total cross section measurements of gold and tantalum at the nELBE photoneutron source

    Hannaske, Roland; Beyer, Roland; Junghans, Arnd; Bemmerer, Daniel; Birgersson, Evert; Ferrari, Anna; Grosse, Eckart; Kempe, Mathias; Kögler, Toni; Marta, Michele; Massarczyk, Ralph; Matic, Andrija; Schramm, Georg; Schwengner, Ronald; Wagner, Andreas

    2014-01-01

    Neutron total cross sections of 197 Au and nat Ta have been measured at the nELBE photoneutron source in the energy range from 0.1 - 10 MeV with a statistical uncertainty of up to 2 % and a total systematic uncertainty of 1 %. This facility is optimized for the fast neutron energy range and combines an excellent t ime structure of the neutron pulses (electron bunch width 5 ps) with a short flight path of 7 m. Because of the low instantaneous neutron flux transmission measurements of neutron total cross sections are possible, that exhibit very different beam and back ground conditions than found at other neutron sources.

  5. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    Dowdall, M. (Norwegian Radiation Protection Authority, OEsteraas (Norway)); Smethurst, M.A. (Univ. of Exeter and Avalonia Geophysics, Cornwall Campus, Penryn (United Kingdom)); Andersson, K. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Aage, H.K. (Danish Emergency Management Agency, Birkeroed (Denmark)); Palsson, S.E. (Icelandic Radiation Protection Institute, Reykjavik (Iceland))

    2011-10-15

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  6. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    Dowdall, M.; Smethurst, M.A.; Andersson, K.; Aage, H.K.; Palsson, S.E.

    2011-10-01

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the aftermath of an accident involving the release of radioactive materials. Despite this expansion, the opportunities for gaining practical experience in the field are limited by cost considerations and practicability. These limitations are exacerbated by the fact that data generated and displayed in the field differ significantly from gamma spectral data generated in a laboratory environment. As a means of exercising existing emergency measuring/surveying capability and introducing carborne measurements to a larger group, a virtual exercise was devised. The exercise ORPEX (Orphan Sources and Fresh Fallout Virtual Exercise in Mobile Measurement) featured two typical emergency scenarios in which carborne measuring systems might be deployed: firstly a search for multiple orphan sources and secondly surveying to delineate patchy fallout from a local release point. In the first scenario, synthetic spectral data were generated for imaginary point sources and inserted into genuine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time limit. In the second scenario, synthetic spectral data representing fallout from a local fire involving radioactive material were added to real carborne data from the Trondheim area. Participants were asked to produce maps that identify and characterise the regions of contamination within the same time limit. Fourteen individual organisations from seven different countries supplied results. Results from participants indicate that for strong sources of isotopes with simple spectra featuring

  7. Radio weak lensing shear measurement in the visibility domain - II. Source extraction

    Rivi, M.; Miller, L.

    2018-05-01

    This paper extends the method introduced in Rivi et al. (2016b) to measure galaxy ellipticities in the visibility domain for radio weak lensing surveys. In that paper, we focused on the development and testing of the method for the simple case of individual galaxies located at the phase centre, and proposed to extend it to the realistic case of many sources in the field of view by isolating visibilities of each source with a faceting technique. In this second paper, we present a detailed algorithm for source extraction in the visibility domain and show its effectiveness as a function of the source number density by running simulations of SKA1-MID observations in the band 950-1150 MHz and comparing original and measured values of galaxies' ellipticities. Shear measurements from a realistic population of 104 galaxies randomly located in a field of view of 1 \\deg ^2 (i.e. the source density expected for the current radio weak lensing survey proposal with SKA1) are also performed. At SNR ≥ 10, the multiplicative bias is only a factor 1.5 worse than what found when analysing individual sources, and is still comparable to the bias values reported for similar measurement methods at optical wavelengths. The additive bias is unchanged from the case of individual sources, but it is significantly larger than typically found in optical surveys. This bias depends on the shape of the uv coverage and we suggest that a uv-plane weighting scheme to produce a more isotropic shape could reduce and control additive bias.

  8. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  9. E-line: A new crystal collimator beam line for source size measurements at CHESS

    White, Jeffrey A. [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)], E-mail: jaw7@cornell.edu; Revesz, Peter; Finkelstein, Ken [CHESS, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14850-8001 (United States)

    2007-11-11

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring.

  10. E-line: A new crystal collimator beam line for source size measurements at CHESS

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  11. Validating criticality calculations for spent fuel with 252Cf-source-driven noise measurements

    Mihalczo, J.T.; Krass, A.W.; Valentine, T.E.

    1992-01-01

    The 252 Cf-Source-driven noise analysis method can be used for measuring the subcritical neutron multiplication factor k of arrays of spent light water reactor (LWR) fuel. This type of measurement provides a parameter that is directly related to the criticality state of arrays of LWR fuel. Measurements of this parameter can verify the criticality safety margins of spent LWR fuel configurations and thus could be a means of obtaining the information to justify burnup credit for spent LWR transportation/storage casks. The practicality of a measurement depends on the ability to install the hardware required to perform the measurement. Source chambers containing the 252 Cf at the required source intensity for this application have been constructed and have operated successfully for ∼10 years and can be fabricated to fit into control rod guide tubes of PWR fuel elements. Fission counters especially developed for spent-fuel measurements are available that would allow measurements of a special 3 x 3 spent fuel array and a typical burnup credit rail cask with spent fuel in unborated water. Adding a moderator around these fission counters would allow measurements with the typical burnup credit rail cask with borated water and the special 3 x 3 array with borated water. The recent work of Ficaro on modifying the KENO Va code to calculate by the Monte Carlo method the time sequences of pulses at two detectors near a fissile assembly from the fission chain multiplication process, initiated by a 252 Cf source in the assembly allows a direct computer calculation of the noise analysis data from this measurement method

  12. A new mini-extrapolation chamber for beta source uniformity measurements

    Oliveira, M.L.; Caldas, L.V.E.

    2006-01-01

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90 Sr+ 90 Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90 Sr+ 90 Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  13. Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-103Pd brachytherapy source

    Sadeghi, Mahdi; Raisali, Gholamreza; Hosseini, S. Hamed; Shavar, Arzhang

    2008-01-01

    This article presents a brachytherapy source having 103 Pd adsorbed onto a cylindrical silver rod that has been developed by the Agricultural, Medical, and Industrial Research School for permanent implant applications. Dosimetric characteristics (radial dose function, anisotropy function, and anisotropy factor) of this source were experimentally and theoretically determined in terms of the updated AAPM Task group 43 (TG-43U1) recommendations. Monte Carlo simulations were used to calculate the dose rate constant. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermoluminescent dosimeters in a Perspex phantom. Precision machined bores in the phantom located the dosimeters and the source in a reproducible fixed geometry, providing for transverse-axis and angular dose profiles over a range of distances from 0.5 to 5 cm. The Monte Carlo N-particle (MCNP) code, version 4C simulation techniques have been used to evaluate the dose-rate distributions around this model 103 Pd source in water and Perspex phantoms. The Monte Carlo calculated dose rate constant of the IRA- 103 Pd source in water was found to be 0.678 cGy h -1 U -1 with an approximate uncertainty of ±0.1%. The anisotropy function, F(r,θ), and the radial dose function, g(r), of the IRA- 103 Pd source were also measured in a Perspex phantom and calculated in both Perspex and liquid water phantoms

  14. Measurement of electron beams profile of pierce type electron source using sensor of used Tv tube

    Darsono; Suhartono; Suprapto; Elin Nuraini

    2015-01-01

    The measurement of an electron beam profile has been performed using electron beam monitor based on method of phosphorescent materials. The main components of the electron beam monitor consists of a fluorescent sensor using a used Tv tube, CCTV camera to record images on a Tv screen, video adapter as interface between CCTV and laptop, and the laptop as a viewer and data processing. Two Pierce-type electron sources diode and triode was measured the shape of electron beam profile in real time. Results of the experiments showed that the triode electron source of Pierce type gave the shape of electron beam profiles better than that of the diode electron source .The anode voltage is not so influential on the beam profile shape. The focused voltage in the triode electron source is so influence to the shape of the electron beam profile, but above 5 kV no great effect. It can be concluded that the electron beam monitor can provide real time observations and drawings shape of the electron beam profile displayed on the used Tv tube glass screen which is the real picture of the shape of the electron beam profile. Triode electron source produces a better electron beam profile than that of the diode electron source. (author)

  15. Measurement of electron emission due to energetic ion bombardment in plasma source ion implantation

    Shamim, M. M.; Scheuer, J. T.; Fetherston, R. P.; Conrad, J. R.

    1991-11-01

    An experimental procedure has been developed to measure electron emission due to energetic ion bombardment during plasma source ion implantation. Spherical targets of copper, stainless steel, graphite, titanium alloy, and aluminum alloy were biased negatively to 20, 30, and 40 kV in argon and nitrogen plasmas. A Langmuir probe was used to detect the propagating sheath edge and a Rogowski transformer was used to measure the current to the target. The measurements of electron emission coefficients compare well with those measured under similar conditions.

  16. Measurements on Pb27+ Sources for the CERN Heavy Ion Injection Chain

    Chamings, J A

    2004-01-01

    CERN, the world's largest particle physics laboratory near Geneva, is currently in the process of building the Large Hadron Collider (LHC). Lead-208 will be used in this accelerator and to meet the injection requirements much work is required to find a suitable and reliable heavy ion source. The work in this report covers two ion sources, the Laser Ion Source (LIS), and the Electron Cyclotron Resonance Ion Source (ECRIS). An emittance measurement, using a pepper pot and CCD camera, was completed on the recently re-installed LIS, measured and analysed to be 140mm.mrad un-normalised and 0.8mm.mrad normalised 4rms for the maximum intensity charge state, Pb27+. A Visual Basic Program was modified to allow Charge State Distribution (CSD) and other scans of the ECRIS at CERN to be taken. Chapter 5 presents the results of the CSD scans taken. This program provided a new method to take 1 dimensional transverse beam profiles. From this a direct emittance measurement was formed for the first time since the source was o...

  17. Advances in Mineral Dust Source Composition Measurement with Imaging Spectroscopy at the Salton Sea, CA

    Green, R. O.; Realmuto, V. J.; Thompson, D. R.; Mahowald, N. M.; Pérez García-Pando, C.; Miller, R. L.; Clark, R. N.; Swayze, G. A.; Okin, G. S.

    2015-12-01

    Mineral dust emitted from the Earth's surface is a principal contributor to direct radiative forcing over the arid regions, where shifts in climate have a significant impact on agriculture, precipitation, and desert encroachment around the globe. Dust particles contribute to both positive and negative forcing, depending on the composition of the particles. Particle composition is a function of the surface mineralogy of dust source regions, but poor knowledge of surface mineralogy on regional to global scales limits the skill of Earth System models to predict shifts in regional climate around the globe. Earth System models include the source, emission, transport and deposition phases of the dust cycle. In addition to direct radiative forcing contributions, mineral dust impacts include indirect radiative forcing, modification of the albedo and melting rates of snow and ice, kinetics of tropospheric photochemistry, formation and deposition of acidic aerosols, supply of nutrients to aquatic and terrestrial ecosystems, and impact on human health and safety. We demonstrate the ability to map mineral dust source composition in the Salton Sea dust source region with imaging spectroscopy measurements acquired as part of the NASA HyspIRI preparatory airborne campaign. These new spectroscopically derived compositional measurements provide a six orders of magnitude improvement over current atlases for this dust source region and provide a pathfinder example for a remote measurement approach to address this critical dust composition gap for global Earth System models.

  18. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  19. The inductively coupled plasma as a source for the measurement of fundamental spectroscopic constants

    Farnsworth, P.B.

    1993-01-01

    Inductively coupled plasmas (ICPs) are stable, robust sources for the generation of spectra from neutral and singly ionized atoms. They are used extensively for analytical spectrometry, but have seen limited use for the measurement of fundamental spectroscopic constants. Several properties of the ICP affect its suitability for such fundamental measurements. They include: spatial structure, spectral background, noise characteristics, electron densities and temperatures, and the state of equilibrium in the plasma. These properties are particularly sensitive to the means by which foreign atoms are introduced into the plasma. With some departures from the operating procedures normally used in analytical measurements, the ICP promise to be a useful source for the measurement of fundamental atomic constants. (orig.)

  20. Orphan Sources and Fresh Fallout: Virtual Exercise in Mobile Measurement (ORPEX)

    Dowdall, M.; Smethurst, M.A.; Andersson, Kasper Grann

    In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying in the afterm......In recent years carborne gamma spectrometry has expanded from its role as a geological survey platform to serving as a useful asset in the field of emergency response to radiological and nuclear situations. Its two main applications are searching for orphan sources and for surveying...... spectral data were generated for imaginary point sources and inserted into genu-ine carborne measurements from in the Trondheim area of Norway. Participants were presented with a typical software tool and data in a range of typical formats and asked to report the source locations and isotopes within a time...

  1. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    Goldman, Ashton H.; Hoover, Kevin B.

    2017-01-01

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  2. Source-to-detector distance and beam center do not affect radiographic measurements of acetabular morphology

    Goldman, Ashton H. [Department of Orthopaedic Surgery, Virginia Commonwealth University, Richmond, VA (United States); Hoover, Kevin B. [Virginia Commonwealth University, Department of Radiology, 1250 E Marshall St. 3rd Floor, PO Box 980615, Richmond, VA (United States)

    2017-04-15

    Multiple radiographic acquisition techniques have been evaluated for their effect on measurements of acetabular morphology. This cadaveric study examined the effect of two acquisition parameters not previously evaluated: beam center position and source-to-detector distance. This study also evaluated the effect of reader differences on measurements. Following calibration of measurements between two readers using five clinical radiographs (training), radiographs were obtained from two cadavers using four different source-to-detector distances and three different radiographic centers for a total of 12 radiographic techniques (experimental). Two physician readers acquired four types of measurements from each cadaver radiograph: lateral center edge angle, peak-to-edge distance, Sharp's angle, and the Tonnis angle. All measurements were evaluated for intra-class correlation coefficient (ICC), kappa statistics for hip dysplasia, and factors that resulted in measurement differences using a mixed statistical model. After training of the two physician readers, there was strong agreement in their hip morphology measurements (ICC 0.84-0.93), agreement in the presence of hip dysplasia (κ = 0.58-1.0), and no measurement difference between physician readers (p = 0.12-1.0). Experimental cadaver measurements showed moderate-to-strong agreement of the readers (ICC 0.74-0.93) and complete agreement on dysplasia (κ = 1). After accounting for reader and radiographic technique, there was no difference in hip morphology measurements (p = 0.83-0.99). In this cadaveric study, measurements of hip morphology were not affected by varying source-to-detector distance or beam center. We conclude that these acquisition parameters are not likely to affect the diagnosis of hip dysplasia in a clinical setting. (orig.)

  3. Measurements of neutron intensity from liquid deuterium moderator of the cold neutron source of KUR

    Kawai, Takeshi; Ebisawa, Toru; Akiyoshi, Tsunekazu; Tasaki, Seiji

    1990-01-01

    The neutron spectra from the liquid deuterium moderator of the cold neutron source of KUR were measured by the time of flight (TOF) method similar to the previous measurements for the liquid hydrogen moderator. The cold neutron gain factor is found to be about 20 ∼ 28 times for the wavelength longer than 6 A. Cold neutron intensities from the liquid deuterium moderator and from the liquid hydrogen moderator are compared and discussed. (author)

  4. Measurement and diagnosis system for 1.2 MV repetitive pulsed power source

    Li Yawei; Deng Jianjun; Xie Min; Feng Zongming; Liu Yuntao; Ma Chenggang

    2010-01-01

    In order to analyze the discharge performance and improve the design of the power system, a set of measurement and diagnosis system for the 1.2 MV repetitive pulsed power source, which supplies the drive power for a high power microwave source, has been designed by studying the high-voltage, high-current testing technology, data acquisition, signal processing, fault diagnosis, virtual instruments and electromagnetic compatibility technology, etc. A resistive-capacitive divider and a Rogowski coil are adopted in measurement; ADLINK corporation's PXI chips are used in data acquisition; data transmission system, condition monitoring and data analysis are developed by LabVIEW. This system can realize on-line monitoring and data analysis for the repetitive pulsed power source. (authors)

  5. Size of nuclear sources from measurements of proton-proton correlations at small relative momentum

    Rebreyend, D.; Kox, S.; Merchez, F.; Noren, B.; Perrin, C.; Khelfaoui, B.; Gondrand, J.C.; Bondorf, J.P.

    1990-01-01

    This contribution will present recent measurements performed on light heavy ion reactions at intermediate energies. Nuclear source sizes were determined by measuring the correlation at small relative momentum, between two protons detected in the EMRIC set-up. This technique allows the determination of the extent of the emitting source by constructing a correlation function for the coincident protons and analyzing it in the framework of a final state interaction model. We found the apparent source size to be large compared to the dimension of the studied system and low sensitivity of the extracted radii as a function of the target mass and detection angle. We will show that simulations may be needed to fully estimate the correlation induced by detectors with small angular acceptance

  6. Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

    Ropponen, T.

    2012-01-01

    This series of slides presents: the Superconducting Source for Ions (SuSI), the X-ray measurement setup, the different collimation schemes, the flat B operation versus B(min) operation, and the impact of tuning ∇B while keeping fixed field profile

  7. Exposition by inhalation to the formaldehyde in the air. Source, measures and concentrations

    Del Gratta, F.; Durif, M.; Fagault, Y.; Zdanevitch, I.

    2004-12-01

    This document presents the main techniques today available to characterize the formaldehyde concentrations in the air for different contexts: urban and rural areas or around industrial installations but also indoor and occupational area. It provides information to guide laboratories and research departments. A synthesis gives also the main emissions sources of these compounds as reference concentrations measured in different environments. (A.L.B.)

  8. Low geometry counter for the absolute measurement of the activity of alpha-emitting sources

    Garcia-Torano, E.; Acena, M.L.

    1989-01-01

    A low-geometry counter is described which allows the absolute determination of the activity for alpha-emitting sources. A Si implanted detector is used to obtain the spectrum of the sample. Two samples are measured with this counter and a 2 π gridded ion chamber. The results an their uncertainties for both instruments are discussed. (Author)

  9. Measuring light spectrum as a main indicator of artificial sources quality

    Piotr Dąbrowski

    2015-05-01

    Full Text Available Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units. On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  10. Estimating values for the moisture source load and buffering capacities from indoor climate measurements

    Schijndel, van A.W.M.

    2008-01-01

    The objective of this study is to investigate the potential for estimating values for the total size of human induced moisture source load and the total buffering (moisture storage) capacity of the interior objects with the use of relatively simple measurements and the use of heat, air, and moisture

  11. Using Generalizability Theory to Disattenuate Correlation Coefficients for Multiple Sources of Measurement Error.

    Vispoel, Walter P; Morris, Carrie A; Kilinc, Murat

    2018-05-02

    Over the years, research in the social sciences has been dominated by reporting of reliability coefficients that fail to account for key sources of measurement error. Use of these coefficients, in turn, to correct for measurement error can hinder scientific progress by misrepresenting true relationships among the underlying constructs being investigated. In the research reported here, we addressed these issues using generalizability theory (G-theory) in both traditional and new ways to account for the three key sources of measurement error (random-response, specific-factor, and transient) that affect scores from objectively scored measures. Results from 20 widely used measures of personality, self-concept, and socially desirable responding showed that conventional indices consistently misrepresented reliability and relationships among psychological constructs by failing to account for key sources of measurement error and correlated transient errors within occasions. The results further revealed that G-theory served as an effective framework for remedying these problems. We discuss possible extensions in future research and provide code from the computer package R in an online supplement to enable readers to apply the procedures we demonstrate to their own research.

  12. HDR 192Ir source speed measurements using a high speed video camera

    Fonseca, Gabriel P.; Viana, Rodrigo S. S.; Yoriyaz, Hélio; Podesta, Mark; Rubo, Rodrigo A.; Sales, Camila P. de; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Purpose: The dose delivered with a HDR 192 Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a 192 Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases

  13. Physics of the 252Cf-source-driven noise analysis measurement

    Valentine, T.E.; Mihalczo, J.T.; Perez, R.B.; Mattingly, J.K.

    1997-01-01

    The 252 Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method's broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between detectors, coherences, and ratios of spectral densities. All of these measured parameters can also be calculated using the MCNP-DSP Monte Carlo code. This paper presents a review of the time-domain signatures obtained from this measurement

  14. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  15. Assessment of grid optimisation measures for the German transmission grid using open source grid data

    Böing, F.; Murmann, A.; Pellinger, C.; Bruckmeier, A.; Kern, T.; Mongin, T.

    2018-02-01

    The expansion of capacities in the German transmission grid is a necessity for further integration of renewable energy sources into the electricity sector. In this paper, the grid optimisation measures ‘Overhead Line Monitoring’, ‘Power-to-Heat’ and ‘Demand Response in the Industry’ are evaluated and compared against conventional grid expansion for the year 2030. Initially, the methodical approach of the simulation model is presented and detailed descriptions of the grid model and the used grid data, which partly originates from open-source platforms, are provided. Further, this paper explains how ‘Curtailment’ and ‘Redispatch’ can be reduced by implementing grid optimisation measures and how the depreciation of economic costs can be determined considering construction costs. The developed simulations show that the conventional grid expansion is more efficient and implies more grid relieving effects than the evaluated grid optimisation measures.

  16. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  17. Influence of neutron scattering and source extent on the measurement of neutron energy spectra at ASDEX

    Huebner, K.; Baetzner, R.; Roos, M.; Robouch, B.V.; Ingrosso, L.; Wurz, H.

    1987-08-01

    The problem of nuclear emulsion measurements at ASDEX is considered. Besides the application of the VINIA-3DAMC software, this needs a description of the plasma neutron source, a model of the ASDEX structure, and calculation of the response of the nuclear emulsion to the incoming spectral neutron fluence. The latter is essential for comparing the numerical results with measurements at ASDEX. To treat this part, the NEPMC software was developed. The aim of the present work is to demonstrate the feasibility, reliability and usefulness of the method. Therefore simplified treatments for the ASDEX model, the plasma neutron source and the track statistics in the NEPMC software were used. Such calculations are of interest not only for nuclear emulsion measurements as well as any other neutron diagnostics, but also for all problems of neutron shielding for other diagnostics. (orig./GG)

  18. Analysis of insertion device magnet measurements for the Advanced Light Source

    Marks, S.; Humphries, D.; Kincaid, B.M.; Schlueter, R.; Wang, C.

    1993-07-01

    The Advanced Light Source (ALS), which is currently being commissioned at Lawrence Berkeley Laboratory, is a third generation light source designed to produce XUV radiation of unprecedented brightness. To meet the high brightness goal the storage ring has been designed for very small electron beam emittance and the undulators installed in the ALS are built to a high degree of precision. The allowable magnetic field errors are driven by electron beam and radiation requirements. Detailed magnetic measurements and adjustments are performed on each undulator to qualify it for installation in the ALS. The first two ALS undulators, IDA and IDB, have been installed. This paper describes the program of measurements, data analysis, and adjustments carried out for these two devices. Calculations of the radiation spectrum, based upon magnetic measurements, are included. Final field integral distributions are also shown. Good field integral uniformity has been achieved using a novel correction scheme, which is also described

  19. Systematic investigation of background sources in neutron flux measurements with a proton-recoil silicon detector

    Marini, P., E-mail: marini@cenbg.in2p3.fr [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Mathieu, L. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Acosta, L. [Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, México D.F. 01000 (Mexico); Aïche, M.; Czajkowski, S.; Jurado, B.; Tsekhanovich, I. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France)

    2017-01-01

    Proton-recoil detectors (PRDs), based on the well known standard H(n,p) elastic scattering cross section, are the preferred instruments to perform precise quasi-absolute neutron flux measurements above 1 MeV. The limitations of using a single silicon detector as PRD at a continuous neutron beam facility are investigated, with the aim of extending such measurements to neutron energies below 1 MeV. This requires a systematic investigation of the background sources affecting the neutron flux measurement. Experiments have been carried out at the AIFIRA facility to identify these sources. A study on the role of the silicon detector thickness on the background is presented and an energy limit on the use of a single silicon detector to achieve a neutron flux precision better than 1% is given.

  20. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  1. Measures Against-Illicit Trafficking of Nuclear Materials and Other Radioactive Sources

    Barakat, M.B.; Nassef, M.H.; El Mongy, S.A.

    2008-01-01

    Since the early nineties, illicit trafficking (IT) of nuclear materials and radioactive sources appeared as a new trend which raised the concern of the international community due to the grave consequences that would merge if these materials or radioactive sources fell into the hands of terrorist groups. However, by the end of the last century illicit trafficking of nuclear materials and radioactive sources lost its considerable salience, in spite of seizure of considerable amounts of 2 '3'5U (76% enrichment) in Bulgaria (May 1999) and also 235 U (30% enrichment) in Georgia (April 2000). Nevertheless, IT should be always considered as a continued and viable threat to the international community. Awareness of the problem should be developed and maintained among concerned circles as the first step towards combating illicit trafficking of nuclear materials and radioactive sources. Illicit trafficking of nuclear and radioactive materials needs serious consideration and proper attention by the governmental law enforcement authorities. Measures to combat with IT of nuclear material or radioactive sources should be effective in recovery, of stolen, removed or lost nuclear materials or radioactive sources due to the failure of the physical protection system or the State System Accounting and Control (SSAC) system which are normally applied for protecting these materials against illegal actions. Measures such as use of modern and efficient radiation monitoring equipment at the borders inspection points, is an important step in preventing the illicit trafficking of nuclear and radioactive materials across the borders. Also providing radiological training to specific personnel and workers in this field will minimize the consequences of a radiological attack in case of its occurrence. There is a real need to start to enter into cooperative agreements to strengthen borders security under the umbrella of IAEA to faster as an international cooperation in the illicit trafficking

  2. Apparatus for measuring moisture in moving bulk material using a lithium-7 radiation source

    Ashe, J.B.

    1976-01-01

    A nucleonic device is described for measuring the moisture content of bulk materials using a radioisotopic fast-neutron source such as lithium-7 admixed with an alpha-particle emitter such as americium-241 as a means of minimizing the thickness of the layer of bulk material required proximate to the moisture sensor for a neutron-reflection moisture gauge for proper operation of said gauge. Minimization of the required thickness of the bulk material permits use of a neutron-reflection moisture gauge for measurements of bulk materials on lightly-loaded belts and other types of conveyors where measurements have previously been impracticable

  3. Lithium Blanket Module dosimetry measurements at the LOTUS 14-MeV neutron source facility

    Tsang, F.Y.; Leo, W.R.; Sahraoui, C.; Wuthrich, S.; Harker, Y.D.

    1986-01-01

    This paper describes the measurements and results of the dosimeter material reaction rates inside the Lithium Blanket Module (LBM) after irradiation by the LOTUS 14-MeV neutron source at the Ecole Polytechnique Federale de Lausanne. The measurement program has been designed to utilize sets of passive dosimeter materials in the form of foils and wires. The dosimetry materials reaction thresholds and interaction response ranges chosen for this series of measurements encompass the entire neutron spectra along the full length of the LBM fuel rods

  4. Measurements of Linac4 H$^{-}$ ion source beam with a magnetized Einzel lens electron dump

    Midttun, O; Scrivens, R

    2014-01-01

    Linac4 is a part of the upgrade of CERN’s accelerator complex for increased luminosity in the LHC. A new system to extract the ion beam from the plasma generator has been designed and tested, in order to improve the reliability and beam optics of the pulsed H- ion source. This paper presents the successfully implemented extraction system and three different beam measurements. The simulations compare well to the measurements and show that the plasma density was too low for the extraction system design during the measurements.

  5. Measuring impairment when diagnosing adolescent ADHD: Differentiating problems due to ADHD versus other sources.

    Vazquez, Alejandro L; H Sibley, Margaret; Campez, Mileini

    2018-04-13

    The DSM-5 requires clinicians to link ADHD symptoms to clinically meaningful impairments in daily life functioning. Measuring impairment during ADHD assessments may be particularly challenging in adolescence, when ADHD is often not the sole source of a youth's difficulties. Existing impairment rating scales are criticized for not specifying ADHD as the source of impairment in their instructions, leading to potential problems with rating scale specificity. The current study utilized a within subjects design (N = 107) to compare parent report of impairment on two versions of a global impairment measure: one that specified ADHD as the source of impairment (Impairment Rating Scale-ADHD) and a standard version that did not (Impairment Rating Scale). On the standard family impairment item, parents endorsed greater impairment as compared to the IRS-ADHD. This finding was particularly pronounced when parents reported high levels of parenting stress. More severe ADHD symptoms were associated with greater concordance between the two versions. Findings indicate that adolescent family related impairments reported during ADHD assessments may be due to sources other than ADHD symptoms, such as developmental maladjustment. To prevent false positive diagnoses, symptom-specific wording may optimize impairment measures when assessing family functioning in diagnostic assessments for adolescents with ADHD. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Comparison of sources of submicron particle number concentrations measured at two sites in Rochester, NY.

    Kasumba, John; Hopke, Philip K; Chalupa, David C; Utell, Mark J

    2009-09-01

    Sources contributing to the submicron particles (100-470 nm) measured between January 2002 and December 2007 at two different New York State Department of Environmental Conservation (NYS DEC) sites in Rochester, NY were identified and apportioned using a bilinear receptor model, positive matrix factorization (PMF). Measurements of aerosol size distributions and number concentrations for particles in the size range of 10-500 nm have been made since December 2001 to date in Rochester. The measurements are being made using a scanning mobility particle sizer (SMPS) consisting of a DMA and a CPC (TSI models 3071 and 3010, respectively). From December 2001 to March 2004, particle measurements were made at the NYS DEC site in downtown Rochester, but it was moved to the eastside of Rochester in May 2004. Each measurement period was divided into three seasons i.e., winter (December, January, and February), summer (June, July, and August), and the transitional periods (March, April, May, September, October, and November) so as to avoid experimental uncertainty resulting from too large season-to-season variability in ambient temperature and solar photon intensity that would lead to unstable/non-stationary size distributions. Therefore, the seasons were analyzed independently for possible sources. Ten sources were identified at both sites and these include traffic, nucleation, residential/commercial heating, industrial emissions, secondary nitrate, ozone- rich secondary aerosol, secondary sulfate, regionally transported aerosol, and a mixed source of nucleation and traffic. These results show that the measured total outdoor particle number concentrations in Rochester generally vary with similar temporal patterns, suggesting that the central monitoring site data can be used to estimate outdoor exposure in other parts of the city.

  7. Interpretation of UV radiometric measurements of spectrally non-uniform sources

    Murphy, P.J.; Gardner, D.G.

    1988-01-01

    Narrow bandpass UV radiometers are used in a variety of high-temperature measurement applications. Significant systematic errors, in the form of an apparent wavelength shift in the system response curve, may be introduced when interpreting data obtained from spectrally nonuniform sources. Theoretical calculations, using transmission curves from commercially available narrow bandpass filters, show that the apparent shift in the system spectral response is a function of temperature for a blackbody source. A brief comparison between the theoretical analysis and experimentaal data is presented

  8. Monte Carlo calculations and measurements of spectra from a C-14 source

    Borg, J.

    1996-05-01

    To perform Monte Carlo simulations it is necessary to model the physical geometries i.e., the source and detector geometry. However, a complete model of the physical geometry may not be possible or may result in a very low calculation efficiency. Substituting the complete source model with a simplified model is one way of increasing the calculation efficiency. In this report, the study of a simplified model of a 14 C source is described. Results of Monte Carlo calculations with the EGS4 code are compared with measurements with a β spectrometer consisting of two coaxial Si detectors, and a low-energy photon spectrometer being a Si(Li) detector. Calculations and measurements show generally good agreement. However, the difference (a factor of 4) between calculated and measured response to electrons for the Si(Li) detector indicates that this detector has a dead layer about 12 μm thick instead of 0.2 μm as reported by the manufacturer. The efficiency of the calculations is increased by a factor of 10, when the complete source model is replaced by the simplified source model. This reduces the calculation time of detector responses to a few days instead of weeks on the NRC SGI R4400 computers. Good agreement between measured and calculated data also verifies that the MC code EGS4 is a reliable and useful tool for simulating coupled electron and photon transport for particles with energies down to a few keV. (au) 3 tabs., 15 ills., 11 refs

  9. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  10. Attribution of climate change, vegetation restoration, and engineering measures to the reduction of suspended sediment in the Kejie catchment, southwest China

    Ma, X.; Lu, X.; Noordwijk, van M.; Li, J.T.; Xu, J.C.

    2014-01-01

    Suspended sediment transport in rivers is controlled by terrain, climate, and human activities. These variables affect hillslope and riverbank erosion at the source, transport velocities and sedimentation opportunities in the river channel, and trapping in reservoirs. The relative importance of

  11. Lower-energy neutron sources for increasing the sensitivity of nuclear gages for measuring the water content of bulk materials

    Bailey, S.M.

    1977-01-01

    The sensitivity of a gage using a nuclear source for measuring the water content of bulk materials, such as plastic concrete, is increased by use of a lithium or fluorine neutron nuclear source. 3 figures

  12. The continental source of glyoxal estimated by the synergistic use of spaceborne measurements and inverse modelling

    A. Richter

    2009-11-01

    Full Text Available Tropospheric glyoxal and formaldehyde columns retrieved from the SCIAMACHY satellite instrument in 2005 are used with the IMAGESv2 global chemistry-transport model and its adjoint in a two-compound inversion scheme designed to estimate the continental source of glyoxal. The formaldehyde observations provide an important constraint on the production of glyoxal from isoprene in the model, since the degradation of isoprene constitutes an important source of both glyoxal and formaldehyde. Current modelling studies underestimate largely the observed glyoxal satellite columns, pointing to the existence of an additional land glyoxal source of biogenic origin. We include an extra glyoxal source in the model and we explore its possible distribution and magnitude through two inversion experiments. In the first case, the additional source is represented as a direct glyoxal emission, and in the second, as a secondary formation through the oxidation of an unspecified glyoxal precursor. Besides this extra source, the inversion scheme optimizes the primary glyoxal and formaldehyde emissions, as well as their secondary production from other identified non-methane volatile organic precursors of anthropogenic, pyrogenic and biogenic origin.

    In the first inversion experiment, the additional direct source, estimated at 36 Tg/yr, represents 38% of the global continental source, whereas the contribution of isoprene is equally important (30%, the remainder being accounted for by anthropogenic (20% and pyrogenic fluxes. The inversion succeeds in reducing the underestimation of the glyoxal columns by the model, but it leads to a severe overestimation of glyoxal surface concentrations in comparison with in situ measurements. In the second scenario, the inferred total global continental glyoxal source is estimated at 108 Tg/yr, almost two times higher than the global a priori source. The extra secondary source is the largest contribution to the global glyoxal

  13. A small-plane heat source method for measuring the thermal conductivities of anisotropic materials

    Cheng, Liang; Yue, Kai; Wang, Jun; Zhang, Xinxin

    2017-07-01

    A new small-plane heat source method was proposed in this study to simultaneously measure the in-plane and cross-plane thermal conductivities of anisotropic insulating materials. In this method the size of the heat source element is smaller than the sample size and the boundary condition is thermal insulation due to no heat flux at the edge of the sample during the experiment. A three-dimensional model in a rectangular coordinate system was established to exactly describe the heat transfer process of the measurement system. Using the Laplace transform, variable separation, and Laplace inverse transform methods, the analytical solution of the temperature rise of the sample was derived. The temperature rises calculated by the analytical solution agree well with the results of numerical calculation. The result of the sensitivity analysis shows that the sensitivity coefficients of the estimated thermal conductivities are high and uncorrelated to each other. At room temperature and in a high-temperature environment, experimental measurements of anisotropic silica aerogel were carried out using the traditional one-dimensional plane heat source method and the proposed method, respectively. The results demonstrate that the measurement method developed in this study is effective and feasible for simultaneously obtaining the in-plane and cross-plane thermal conductivities of the anisotropic materials.

  14. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source

    Waldmann, Ole; Ludewigt, Bernhard [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2011-11-15

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm{sup 2} have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material.

  15. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source.

    Waldmann, Ole; Ludewigt, Bernhard

    2011-11-01

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm(2) have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material. © 2011 American Institute of Physics

  16. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-01-01

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years

  17. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  18. Simulation of neutron multiplicity measurements using Geant4. Open source software for nuclear arms control

    Kuett, Moritz

    2016-07-07

    Nuclear arms control, including nuclear safeguards and verification technologies for nuclear disarmament typically use software as part of many different technological applications. This thesis proposes to use three open source criteria for such software, allowing users and developers to have free access to a program, have access to the full source code and be able to publish modifications for the program. This proposition is presented and analyzed in detail, together with the description of the development of ''Open Neutron Multiplicity Simulation'', an open source software tool to simulate neutron multiplicity measurements. The description includes physical background of the method, details of the developed program and a comprehensive set of validation calculations.

  19. A novel method for direct localized sound speed measurement using the virtual source paradigm

    Byram, Brett; Trahey, Gregg E.; Jensen, Jørgen Arendt

    2007-01-01

    ) mediums. The inhomogeneous mediums were arranged as an oil layer, one 6 mm thick and the other 11 mm thick, on top of a water layer. To complement the phantom studies, sources of error for spatial registration of virtual detectors were simulated. The sources of error presented here are multiple sound...... registered virtual detector. Between a pair of registered virtual detectors a spherical wave is propagated. By beamforming the received data the time of flight between the two virtual sources can be calculated. From this information the local sound speed can be estimated. Validation of the estimator used...... both phantom and simulation results. The phantom consisted of two wire targets located near the transducer's axis at depths of 17 and 28 mm. Using this phantom the sound speed between the wires was measured for a homogeneous (water) medium and for two inhomogeneous (DB-grade castor oil and water...

  20. Characterization of the main error sources of chromatic confocal probes for dimensional measurement

    Nouira, H; El-Hayek, N; Yuan, X; Anwer, N

    2014-01-01

    Chromatic confocal probes are increasingly used in high-precision dimensional metrology applications such as roughness, form, thickness and surface profile measurements; however, their measurement behaviour is not well understood and must be characterized at a nanometre level. This paper provides a calibration bench for the characterization of two chromatic confocal probes of 20 and 350 µm travel ranges. The metrology loop that includes the chromatic confocal probe is stable and enables measurement repeatability at the nanometer level. With the proposed system, the major error sources, such as the relative axial and radial motions of the probe with respect to the sample, the material, colour and roughness of the measured sample, the relative deviation/tilt of the probe and the scanning speed are identified. Experimental test results show that the chromatic confocal probes are sensitive to these errors and that their measurement behaviour is highly dependent on them. (paper)

  1. Quality Attribute Design Primitives

    Bass, Len

    2000-01-01

    This report focuses on the quality attribute aspects of mechanisms. An architectural mechanism is a 'structure whereby objects collaborate to provide some behavior that satisfies a requirement of the problem...

  2. 228Ra and 226Ra measurement on a BaSO4 co-precipitation source

    Medley, Peter; Martin, Paul; Bollhöfer, Andreas; Parry, David

    2015-01-01

    One of the most commonly-used methods for determination of 226 Ra, particularly in water samples, utilises co-precipitation of Ra with BaSO 4 , followed by microfiltration to produce a source for alpha counting. This paper describes two extensions to BaSO 4 co-precipitation methods which enable determination of 228 Ra using the same source. The adaptations presented here do not introduce any contaminants that will affect the separation of radium or alpha counting for 226 Ra, and can be used for re-analysis of already existing sources prepared by BaSO 4 co-precipitation. The first adaptation uses detection of 228 Ac on the source by gamma spectrometry. The detection efficiency is high, allowing analysis of water samples at sufficiently low activity to be suitable in testing for compliance with drinking water quality standards. As 228 Ac grows in quickly, taking less than 2 days to reach equilibrium with the 228 Ra parent, this can also be useful in radiological emergency response situations. The second adaptation incorporates a method for the digestion of BaSO 4 sources, allowing separation of thorium and subsequent determination of 228 Th activity. Although ingrowth periods for 228 Th can be lengthy, very low detection limits for 228 Ra can be achieved with this technique. - Highlights: • We developed two methods for 228 Ra measurement on Ba(Ra)SO 4 co-precipitation sources. • Measurement by gamma spectrometry using the daughter 228 Ac is rapid. • Detection limits are suitable for assessment of drinking water quality. • The second approach uses alpha spectrometry on a separated Th fraction. • This is more sensitive than gamma spectrometry after an ingrowth period greater than about 1 month

  3. High order statistical signatures from source-driven measurements of subcritical fissile systems

    Mattingly, J.K.

    1998-01-01

    This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility in a variety of applications. Potential applications include enhanced radiation signature identification of weapons components for nuclear disarmament and safeguards applications and augmented nondestructive analysis of spent nuclear fuel. In general, these techniques expand present capabilities in the analysis of subcritical measurements

  4. Measurement of acoustic characteristics of Japanese Buddhist temples in relation to sound source location and direction.

    Soeta, Yoshiharu; Shimokura, Ryota; Kim, Yong Hee; Ohsawa, Tomohiro; Ito, Ken

    2013-05-01

    Although temples are important buildings in the Buddhist community, the acoustic quality has not been examined in detail. Buddhist monks change the location and direction according to the ceremony, and associated acoustical changes have not yet been examined scientifically. To discuss the desired acoustics of temples, it is necessary to know the acoustic characteristics appropriate for each phase of a ceremony. In this study, acoustic measurements were taken at various source locations and directions in Japanese temples. A directional loudspeaker was used as the source to provide vocal acoustic fields, and impulse responses were measured and analyzed. The speech transmission index was higher and the interaural cross-correlation coefficient was lower for the sound source directed toward the side wall than that directed toward the altar. This suggests that the change in direction improves speech intelligibility, and the asymmetric property of direct sound and complex reflections from the altar and side wall increases the apparent source width. The large and coupled-like structure of the altar of a Buddhist temple may have reinforced the reverberation components and the table in the altar, which is called the "syumidan," may have decreased binaural coherence.

  5. MEASURING THE UNDETECTABLE: PROPER MOTIONS AND PARALLAXES OF VERY FAINT SOURCES

    Lang, Dustin; Hogg, David W.; Jester, Sebastian; Rix, Hans-Walter

    2009-01-01

    The near future of astrophysics involves many large solid-angle, multi-epoch, multiband imaging surveys. These surveys will, at their faint limits, have data on a large number of sources that are too faint to be detected at any individual epoch. Here, we show that it is possible to measure in multi-epoch data not only the fluxes and positions, but also the parallaxes and proper motions of sources that are too faint to be detected at any individual epoch. The method involves fitting a model of a moving point source simultaneously to all imaging, taking account of the noise and point-spread function (PSF) in each image. By this method it is possible to measure the proper motion of a point source with an uncertainty close to the minimum possible uncertainty given the information in the data, which is limited by the PSF, the distribution of observation times (epochs), and the total signal-to-noise in the combined data. We demonstrate our technique on multi-epoch Sloan Digital Sky Survey (SDSS) imaging of the SDSS Southern Stripe (SDSSSS). We show that with our new technique we can use proper motions to distinguish very red brown dwarfs from very high-redshift quasars in these SDSS data, for objects that are inaccessible to traditional techniques, and with better fidelity than by multiband imaging alone. We rediscover all 10 known brown dwarfs in our sample and present nine new candidate brown dwarfs, identified on the basis of significant proper motion.

  6. Study of principle error sources in gamma spectrometry. Application to cross sections measurement

    Majah, M. Ibn.

    1985-01-01

    The principle error sources in gamma spectrometry have been studied in purpose to measure cross sections with great precision. Three error sources have been studied: dead time and pile up which depend on counting rate, and coincidence effect that depends on the disintegration scheme of the radionuclide in question. A constant frequency pulse generator has been used to correct the counting loss due to dead time and pile up in cases of long and short disintegration periods. The loss due to coincidence effect can reach 25% and over, depending on the disintegration scheme and on the distance source-detector. After establishing the correction formula and verifying its validity for four examples: iron 56, scandium 48, antimony 120 and gold 196 m, an application has been done by measuring cross sections of nuclear reactions that lead to long disintegration periods which need short distance source-detector counting and thus correcting the loss due to dead time effect, pile up and coincidence effect. 16 refs., 45 figs., 25 tabs. (author)

  7. Inversion of GPS-measured coseismic displacements for source parameters of Taiwan earthquake

    Lin, J. T.; Chang, W. L.; Hung, H. K.; Yu, W. C.

    2016-12-01

    We performed a method of determining earthquake location, focal mechanism, and centroid moment tensor by coseismic surface displacements from daily and high-rate GPS measurements. Unlike commonly used dislocation model where fault geometry is calculated nonlinearly, our method makes a point source approach to evaluate these parameters in a solid and efficient way without a priori fault information and can thus provide constrains to subsequent finite source modeling of fault slip. In this study, we focus on the resolving ability of GPS data for moderate (Mw=6.0 7.0) earthquakes in Taiwan, and four earthquakes were investigated in detail: the March 27 2013 Nantou (Mw=6.0), the June 2 2013 Nantou (Mw=6.3) , the October 31 2013 Ruisui (Mw=6.3), and the March 31 2002 Hualien (ML=6.8) earthquakes. All these events were recorded by the Taiwan continuous GPS network with data sampling rates of 30-second and 1 Hz, where the Mw6.3 Ruisui earthquake was additionally recorded by another local GPS network with a sampling rate of 20 Hz. Our inverted focal mechanisms of all these earthquakes are consistent with the results of GCMT and USGS that evaluates source parameters by dynamic information from seismic waves. We also successfully resolved source parameters of the Mw6.3 Ruisui earthquake within only 10 seconds following the earthquake occurrence, demonstrating the potential of high-rate GPS data on earthquake early warning and real-time determination of earthquake source parameters.

  8. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Voutta, R.; Gerstl, S.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; Saez de Jauregui, D.; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Migliorati, M.; Spataro, B.

    2016-05-01

    The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  9. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    R. Voutta

    2016-05-01

    Full Text Available The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS. In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  10. Measuring the Plasma Density of a Ferroelectric Plasma Source in an Expanding Plasma

    Dunaevsky, A.; Fisch, N.J.

    2003-01-01

    The initial density and electron temperature at the surface of a ferroelectric plasma source were deduced from floating probe measurements in an expanding plasma. The method exploits negative charging of the floating probe capacitance by fast flows before the expanding plasma reaches the probe. The temporal profiles of the plasma density can be obtained from the voltage traces of the discharge of the charged probe capacitance by the ion current from the expanding plasma. The temporal profiles of the plasma density, at two different distances from the surface of the ferroelectric plasma source, could be further fitted by using the density profiles for the expanding plasma. This gives the initial values of the plasma density and electron temperature at the surface. The method could be useful for any pulsed discharge, which is accompanied by considerable electromagnetic noise, if the initial plasma parameters might be deduced from measurements in expanding plasma

  11. Measurement and calculation of radiation sources in the primary cooling system of JOYO

    Suzuki, S.; Iizawa, K.; Ohtani, N.; Kobayashi, T.; Horie, J.; Handa, H.

    1987-01-01

    Production and transfer of radiation sources in the primary cooling system are important consideration in the LMFBR plant from the viewpoint of radiation protection and shielding design. These items were evaluated with calculations and/or measurements in the Japanese experimental fast reactor JOYO. In this study, calculations were made with the DOT3.5 0 two-dimensional discrete ordinate transport code to determine the neutron flux and production rate distributions of radiation sources in the reactor vessel. Using the DOT results, the behavior in primary coolant sodium of the CP (radioactive corrosion products) which were released from the reactor structural material was also calculationally analyzed with the PSYCHE code developed by PNC. These analytical results were compared with the measured results to get the verification of analysis methods and to estimate the accuracy of calculations

  12. Understanding data sources to measure patient retention in HIV care in sub-Saharan Africa.

    Clouse, Kate; Phillips, Tamsin; Myer, Landon

    2017-07-01

    Antiretroviral therapy (ART) programs in sub-Saharan Africa are moving towards universal treatment, yet the success of these programs is threatened by gaps within the continuum of HIV care. In this commentary, we seek to draw attention to the advantages and limitations of different data sources currently used for measuring retention in HIV care. Within the context of a piecemeal combination of imperfect data sources, selecting a gold standard of collecting retention data is difficult. Currently, our data systems for measuring retention provide an incomplete picture of the health of our national ART systems and, thus, the health of our patients. © The Author 2017. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Acoustical source reconstruction from non-synchronous sequential measurements by Fast Iterative Shrinkage Thresholding Algorithm

    Yu, Liang; Antoni, Jerome; Leclere, Quentin; Jiang, Weikang

    2017-11-01

    Acoustical source reconstruction is a typical inverse problem, whose minimum frequency of reconstruction hinges on the size of the array and maximum frequency depends on the spacing distance between the microphones. For the sake of enlarging the frequency of reconstruction and reducing the cost of an acquisition system, Cyclic Projection (CP), a method of sequential measurements without reference, was recently investigated (JSV,2016,372:31-49). In this paper, the Propagation based Fast Iterative Shrinkage Thresholding Algorithm (Propagation-FISTA) is introduced, which improves CP in two aspects: (1) the number of acoustic sources is no longer needed and the only making assumption is that of a "weakly sparse" eigenvalue spectrum; (2) the construction of the spatial basis is much easier and adaptive to practical scenarios of acoustical measurements benefiting from the introduction of propagation based spatial basis. The proposed Propagation-FISTA is first investigated with different simulations and experimental setups and is next illustrated with an industrial case.

  14. Measurement of thermal conductivity of uranium metal using transient plane source technique

    Subramanian, G.G.S.; Bapuji, T.; Panneerselvam, G.; Antony, M.P.; Nagarajan, K.

    2012-01-01

    Thermo physical properties of fuel, cladding and structural materials play a significant role in the reactor operation. Thermal conductivity is one of the most important physical properties of the fuel which determines the maximum linear heat rating of the fuel in a reactor. As part of this study, the thermal conductivity of uranium metal was measured using a transient plane source (TPS) by Hot-disc method

  15. X-ray stress measurement by use of synchrotron radiation source

    Yoshioka, Yasuo; Matsui, Hisaaki; Moro-oka, Toshimasa; Hasegawa, Ken-ichi; Nakajima, Tetsuo.

    1986-01-01

    In the field of X-ray stress measurement of polycrystalline materials, a diffraction plane at higher Bragg angle has to be selected in order to obtain the precise value of stress. However, the stress measurement on an optional (hkl) plane desired is not always possible because the X-ray beam exited from a metal target has a dispersive wave length. Recently, we have been able to use the synchrotron radiation source (SR) as an excellent X-ray source. In Japan, the facility of synchrotron radiation (Photon Factory, PF) was constructed in the National Laboratory for High Energy Physics (KEK) at Tsukuba academic city. The use of this SR enables the stress measurements on many (hkl) planes with high accuracy in the higher Bragg angle region by providing an X-ray beam having an optional wave length. We have started the X-ray stress analysis by use of the synchrotron radiation source. This paper reports the system of measurement and some results of preliminaly experiments. Since a monochromatic X-ray beam is required for the stress measurement, we used a beam line which consists of a double crystal monochrometer and a focusing mirror. X-rays between 4 KeV (λ = 0.31 nm) and 10 KeV (λ = 0.12 nm) are available with this optical system. We adopted a constant Bragg angle of 2θ = 154 deg for all the diffraction planes. A PSPC having a carbon fiber anode is made and used as a detector with the use of a fast digital signal processor. We could observe the diffraction profiles from (200), (211), (220), (310) and (321) crystal plane of alpha iron, respectively, and the residual stresses in these planes except the (200) plane were measured with high accuracy in a short time. Such feature especially suits the stress analysis of the material which has preferred orientation or stress gradient. (author)

  16. Sources of variability in OSL dose measurements using single grains of quartz

    Thomsen, K.J.; Murray, A.S.; Boetter-Jensen, L.

    2005-01-01

    In luminescence-based measurements of dose distributions in unheated mineral samples, the observed spread in dose values is usually attributed to four main factors: fluctuations in the number of photons counted, incomplete zeroing of any prior trapped charge (including signals arising from thermal transfer), heterogeneity in dosimetry, and instrument reproducibility. For correct interpretation of measured dose distributions in retrospective dosimetry, it is important to understand the relative importance of these components, and to establish whether other factors also contribute to the observed spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation was designed to deliver a uniform dose to the sample. Thus it was anticipated that statistical fluctuations in the number of photons counted and instrument reproducibility, both quantifiable entities, should be able to account for all the observed variance in the measured dose distributions. We examine this assumption in detail, and discuss the origins and importance of the residual variance in our data

  17. The Dynamic Method for Time-of-Flight Measurement of Thermal Neutron Spectra from Pulsed Sources

    Pepelyshev, Yu.N.; Tulaev, A.B.; Bobrakov, V.F.

    1994-01-01

    The time-of-flight method for a measurement of thermal neutron spectra in the pulsed neutron sources with high efficiency of neutron registration, more than 10 5 times higher in comparison with traditional one, is described. The main problems connected with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of a special neutron detector design and other questions are discussed. Some experimental results, spectra from surfaces of the water and solid methane moderators, obtained in the pulsed reactor IBR-2 (Dubna, Russia) are presented. 4 refs., 5 figs

  18. A fission ionization detector for neutron flux measurements at a spallation source

    Wender, S.A. (Los Alamos National Lab., Los Alamos, NM (United States)); Balestrini, S. (Los Alamos National Lab., Los Alamos, NM (United States)); Brown, A. (Los Alamos National Lab., Los Alamos, NM (United States)); Haight, R.C. (Los Alamos National Lab., Los Alamos, NM (United States)); Laymon, C.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lee, T.M. (Los Alamos National Lab., Los Alamos, NM (United States)); Lisowski, P.W. (Los Alamos National Lab., Los Alamos, NM (United States)); McCorkle, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Nelson, R.O. (Los Alamos National Lab., Los Alamos, NM (United States)); Parker, W. (Los Alamos National Lab., Los Alamos, NM (United States)); Hill, N.W. (Oak Ridge National Lab., Oak Ridge, TN (United States))

    1993-11-15

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  19. A fission ionization detector for neutron flux measurements at a spallation source

    Wender, S.A.; Balestrini, S.; Brown, A.; Haight, R.C.; Laymon, C.M.; Lee, T.M.; Lisowski, P.W.; McCorkle, W.; Nelson, R.O.; Parker, W.; Hill, N.W.

    1993-01-01

    The construction of a neutron flux monitor that can measure absolute neutron intensities in the neutron energy range from below 1 MeV to over 500 MeV is described. The detector consists of an ionization chamber with several thin deposits of fissionable material. The ionization chamber is thin enough that it does not significantly affect the neutron beam and may be left in the neutron flight path during experimental measurements to continuously monitor the beam flux. The use of this monitor at the continuous-energy spallation neutron source at the WNR target area at LAMPF is described. (orig.)

  20. Electron Source Brightness and Illumination Semi-Angle Distribution Measurement in a Transmission Electron Microscope.

    Börrnert, Felix; Renner, Julian; Kaiser, Ute

    2018-05-21

    The electron source brightness is an important parameter in an electron microscope. Reliable and easy brightness measurement routes are not easily found. A determination method for the illumination semi-angle distribution in transmission electron microscopy is even less well documented. Herein, we report a simple measurement route for both entities and demonstrate it on a state-of-the-art instrument. The reduced axial brightness of the FEI X-FEG with a monochromator was determined to be larger than 108 A/(m2 sr V).

  1. The dynamic method for time-of-flight measurement of thermal neutron spectra from pulsed sources

    Pepyolyshev, Yu.N.; Chuklyaev, S.V.; Tulaev, A.B.; Bobrakov, V.F.

    1995-01-01

    A time-of-flight method for measurement of thermal neutron spectra in pulsed neutron sources with an efficiency more than 10 5 times higher than the standard method is described. The main problems associated with the electric current technique for time-of-flight spectra measurement are examined. The methodical errors, problems of special neutron detector design and other questions are discussed. Some experimental results for spectra from the surfaces of water and solid methane moderators obtained at the IBR-2 pulsed reactor (Dubna, Russia) are presented. (orig.)

  2. Ion source plasma parameters measurement based on Langmuir probe with commercial frequency sweep

    Xie, Y.H.; Hu, C.D.; Liu, S.; Shong, S.H.; Jiang, C.C.; Liu, Z.M.

    2010-01-01

    Langmuir probe is one of the main diagnostic tools to measure the plasma parameters in the ion source. In this article, the commercial frequency power, which is sine wave of 50 Hz, was supplied on the Langmuir probe to measure the plasma parameters. The best feature of this probe sweep voltage is that it does not need extra design. The probe I-V characteristic curve can be got in less than 5 ms and the plasma parameters, the electron temperature and the electron density, varying with the time can be got in one plasma discharge of 400 ms.

  3. Evolutionary Influences on Attribution and Affect

    Jennie Brown

    2017-12-01

    Full Text Available Evolutionary theory was applied to Reeder and Brewer's schematic theory and Trafimow's affect theory to extend this area of research with five new predictions involving affect and ability attributions, comparing morality and ability attributions, gender differences, and reaction times for affect and attribution ratings. The design included a 2 (Trait Dimension Type: HR, PR × 2 (Behavior Type: morality, ability × 2 (Valence: positive, negative × 2 (Replication: original, replication × 2 (Sex: female or male actor × 2 (Gender: female or male participant × 2 (Order: attribution portion first, affect portion first mixed design. All factors were within participants except the order and participant gender. Participants were presented with 32 different scenarios in which an actor engaged in a concrete behavior after which they made attributions and rated their affect in response to the behavior. Reaction times were measured during attribution and affect ratings. In general, the findings from the experiment supported the new predictions. Affect was related to attributions for both morality and ability related behaviors. Morality related behaviors received more extreme attribution and affect ratings than ability related behaviors. Female actors received stronger attribution and affect ratings for diagnostic morality behaviors compared to male actors. Male and female actors received similar attribution and affect ratings for diagnostic ability behaviors. Diagnostic behaviors were associated with lower reaction times than non-diagnostic behaviors. These findings demonstrate the utility of evolutionary theory in creating new hypotheses and empirical findings in the domain of attribution.

  4. Design of x-ray diagnostic beam line for a synchrotron radiation source and measurement results

    Garg, Akash Deep, E-mail: akash-deep@rrcat.gov.in; Karnewar, A.K.; Ojha, A.; Shrivastava, B.B.; Holikatti, A.C.; Puntambekar, T.A.; Navathe, C.P.

    2014-08-01

    Indus-2 is a 2.5 GeV synchrotron radiation source (SRS) operational at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We have designed, developed and commissioned x-ray diagnostic beam line (X-DBL) at the Indus-2. It is based on pinhole array imaging (8–18 keV). We have derived new equations for online measurements of source position and emission angle with pinhole array optics. Measured values are compared with the measurements at an independent x-ray beam position monitor (staggered pair blade monitor) installed in the X-DBL. The measured values are close to the theoretical expected values within ±12 µm (or ±1.5 μrad) for sufficiently wide range of the beam movements. So, beside the beam size and the beam emittance, online information for the vertical position and angle is also used in the orbit steering. In this paper, the various design considerations of the X-DBL and online measurement results are presented.

  5. EMF Rapid Program Engineering Projects, Project 1, Development of Recommendations for Guidelines for Field Source Measurement

    Electric Research and Management, Inc.

    1997-03-11

    The goal of this project is to develop a protocol for measuring the electric and magnetic fields around sources. Data from these measurements may help direct future biological effects research by better defining the complexity of magnetic and electric fields to which humanity is exposed, as well asprovide the basis for rigorous field exposure analysis and risk assessment once the relationship between field exposure and biological response. is better understood. The data base also should have sufficient spatial and temporal characteristics to guide electric and magnetic field management. The goal of Task A is to construct a set of characteristics that would be ideal to have for guiding and interpreting biological studies and for focusing any future effort at field management. This ideal set will then be quantified and reduced according to the availability (or possible development of) instrumentation to measure the desired characteristics. Factors that also will be used to define pragmatic data sets will be the cost of collecting the data, the cost of developing an adequate data base, and the needed precision in measuring specific characteristics. A field, electric or magnetic, will always be ,some function of time and space. The first step in this section of the protocol development will be to determine what span of time and what portion of space are required to quantify the electric and magnetic fields around sources such as appliances and electrical apparatus. Constraints on time will be set by examining measurement limitations and biological data requirements.

  6. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  7. Oceans circulation and electron cyclotron resonance sources: Measurement of the AR-39 isotopic ratio in Seawater

    Gaelens, M.; Loiselet, M.; Ryckewaert, G.; Pardo, R.C.; Scott, R.H.; Vondrasek, R.; Collon, Ph.; Kutchera, W.

    2004-01-01

    The radionuclide 39 Ar is produced in the atmosphere by cosmic rays and has an isotopic abundance of 8.1x10 -16 . Because its half life (T 1/2 =269 years) is well matched to the time periods involved in the oceanic currents around the Earth, the measurement of the 39 Ar isotopic ratio is an ideal tool to date ocean water from different depths. It would complement the information gained by the 14 C measurements (T 1/2 =5730 years). However, the measurement of the isotopic ratio 39 Ar/ 40 Ar is a technical challenge: 1 L of modern ocean water contains ∼6500 atoms of 39 Ar, and produces ∼17 decays per year. Although it has been possible to detect the 39 Ar decays in large volumes of sea water by using the low level counting technique, the possibility of measuring the number of 39 Ar atoms faster and in smaller samples using the accelerator mass spectrometry (AMS) technique would be a major breakthrough for this type of measurement. The development of a viable AMS method for 39 Ar has been underway for several years at Argonne National Laboratory, and is presently hampered by the presence of stable 39 K ions coming from the ion source. Although the intensity of this isobaric contaminant is low (∼pA extracted from the source), it has to be compared with the 39 Ar beam intensity (atoms per minutes). In order to separate these two beams (whose mass difference is only 1.6x10 -5 ), the intensity of the 39 K beam coming from the ion source has to be reduced by several orders of magnitude. This reduction has been investigated both at Argonne National Laboratory and at Louvain-la-Neuve. Two techniques have been tried out. In the first, a quartz liner is used to provide a clean surface, while in the second these impurities are buried in a SiO 2 layer formed in situ by running the source with a mixture of silane and oxygen. The 39 K background has been reduced by a factor of 100 with these treatments. These techniques and their results obtained both at Argonne and Louvain

  8. Temporal context for authorship attribution

    Hansen, Niels Dalum; Lioma, Christina; Larsen, Birger

    2014-01-01

    A study of temporal aspects of authorship attribution - a task which aims to distinguish automatically between texts written by different authors by measuring textual features. This task is important in a number of areas, including plagiarism detection in secondary education, which we study...... world data from Danish secondary school students show 84% prediction accuracy when using all available material and 71.9% prediction accuracy when using only the five most recent writing samples from each student....

  9. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  10. Composition and Sources of Particulate Matter Measured near Houston, TX: Anthropogenic-Biogenic Interactions

    Jeffrey K. Bean

    2016-05-01

    Full Text Available Particulate matter was measured in Conroe, Texas (~60 km north of downtown Houston, Texas during the September 2013 DISCOVER-AQ campaign to determine the sources of particulate matter in the region. The measurement site is influenced by high biogenic emission rates as well as transport of anthropogenic pollutants from the Houston metropolitan area and is therefore an ideal location to study anthropogenic-biogenic interactions. Data from an Aerosol Chemical Speciation Monitor (ACSM suggest that on average 64 percent of non-refractory PM1 was organic material, including a high fraction (27%–41% of organic nitrates. There was little diurnal variation in the concentrations of ammonium sulfate; however, concentrations of organic and organic nitrate aerosol were consistently higher at night than during the day. Potential explanations for the higher organic aerosol loadings at night include changing boundary layer height, increased partitioning to the particle phase at lower temperatures, and differences between daytime and nighttime chemical processes such as nitrate radical chemistry. Positive matrix factorization was applied to the organic aerosol mass spectra measured by the ACSM and three factors were resolved—two factors representing oxygenated organic aerosol and one factor representing hydrocarbon-like organic aerosol. The factors suggest that the measured aerosol was well mixed and highly processed, consistent with the distance from the site to major aerosol sources, as well as the high photochemical activity.

  11. Measurements of gamma-ray dose from a moderated 252Cf source

    McDonald, J.C.; Griffith, R.V.; Plato, P.; Miklos, J.

    1983-06-01

    The gamma-ray dose fraction from a moderated 252 Cf source was determined by using three types of dosimetry systems. Measurements were carried out in air at a distance of 35 cm from the surface of the moderating sphere (50 cm from the source which is at the center of the sphere) to the geometrical center of each detector. The moderating sphere is 0.8-mm-thick stainless steel shell filled with D 2 O and covered with 0.5 mm of cadmium. Measurements were also carried out with instruments and dosimeters positioned at the surface of a 40 cm x 40 cm x 15 cm plexiglass irradiation phantom whose front surface was also 35 cm from the surface of the moderating sphere. A-150 tissue-equivalent (TE) plastic ionization chambers and a TE proportional counter (TEPC) were used to measure tissue dose, from which the neutron dose equivalent was computed. The ratio of gamma-ray dose to the neutron dose equivalent was determined by using a relatively neutron-insensitive Geiger-Mueller (GM) counter and thermoluminescent dosimeters (TLD). In addition, the event-size spectrum measured by the TEPC was also used to compute the gamma-ray dose fraction. The average value for the ratio of gamma-ray dose to neutron dose equivalent was found to be 0.18 with an uncertainty of about +-18%

  12. Measurements of the cesium flow from a surface-plasma H- ion source

    Smith, H.V.; Allison, P.W.

    1979-01-01

    A surface ionization gauge (SIG) was constructed and used to measure the Cs 0 flow rate through the emission slit of a surface-plasma source (SPS) of H - ions with Penning geometry. The equivalent cesium density in the SPS discharge is deduced from these flow measurements. For dc operation the optimum H - current occurs at an equivalent cesium density of approx. 7 x 10 12 cm -3 (corresponding to an average cesium consumption rate of 0.5 mg/h). For pulsed operation the optimum H - current occurs at an equivalent cesium density of approx. 2 x 10 13 cm -3 (1-mg/h average cesium consumption rate). Cesium trapping by the SPS discharge was observed for both dc and pulsed operation. A cesium energy of approx. 0.1 eV is deduced from the observed time of flight to the SIG. In addition to providing information on the physics of the source, the SIG is a useful diagnostic tool for source startup and operation

  13. World energy consumption 1800-2000: definitions and measurements, information sources, results

    Martin-Amouroux, Jean-Marie

    2015-10-01

    A first article discusses definitions and measurements used to assess world energy consumption, notably the differences between primary, secondary, final and useful levels. The author identifies the different sources of primary energies (endo-somatic and exo-somatic), the various measurement units, and the spatial organisation of consumption statistics (national data bases, regional consolidations). The second article comments the available sources of information and their history (existing long chronological series at the world scale before and after World War 2), presents the evolution of world energy consumption according to Palmer Putnam, indicates and comments national studies on energy consumption for very long periods (USA, UK, France, and other countries). Then the author discusses the assessment of non commercial consumptions. He mentions and comments studies performed in the USA, in France, in Italy and in other countries, and also some assessments of biomass consumption. He finally discusses the availability of statistics on the evolution of world population. The third article presents and comments results obtained for the evolution of world consumption (world consumption per source of primary energy, per region) for the evolution of energy consumption in Africa, in Northern America, in Latin America, in Asia, in Russia and Eastern Europe and in Western Europe since 1800. Tables give these evolutions for coal, oil, natural gas, electricity, and biomass

  14. Investigation of particle transport through the measurement of the electron source in the Texas Experimental Tokamak

    Klepper, C.C.

    1985-01-01

    The spatial distribution of the electron source was measured spectroscopically in the Texas Experimental Tokamak. The method used involves the measurement of the emissivity of the Balmer α and β lines of neutral hydrogen. Modeling of the corresponding atomic transitions provides a relation between the emissivities and the electron source from the ionization of neutrals. Toroidal distributions were obtained by means of a set of relatively calibrated photodiode amplifier-filter packages referred to as plasma light monitors. Such monitors were distributed toroidally, and attached primarily to radial ports. Specially constructed, absolutely calibrated monitors provided absolute calibration. A scanning, rotating mirror system provided in-out brightness profiles. A TV camera system, viewing the limiter through a tangential port, provided a qualitative description of the poloidal asymmetry. Such description was necessary for the inversion of the rotating mirror data. Using electron density profiles obtained by means of far-infrared interferometry, and integrating the electron sources, the global particle confinement time (tau/sub p/) was computed. Parameter scans were performed in ohmically heated plasmas, varying the toroidal field, the plasma current, the electron density, and the plasma position with respect to the center of the poloidal ring limiter. It was found that tau/sub p/ peaks for a critical density that is independent of the other parameters

  15. Target-ion source unit ionization efficiency measurement by method of stable ion beam implantation

    Panteleev, V.N; Fedorov, D.V; Moroz, F.V; Orlov, S.Yu; Volkov, Yu.M

    The ionization efficiency is one of the most important parameters of an on-line used target-ion source system exploited for production of exotic radioactive beams. The ionization efficiency value determination as a characteristic of a target-ion source unit in the stage of its normalizing before on-line use is a very important step in the course of the preparation for an on-line experiment. At the IRIS facility (Petersburg Nuclear Physics Institute, Gatchina) a reliable and rather precise method of the target-ion source unit ionization efficiency measurement by the method of stable beam implantation has been developed. The method worked out exploits an off-line mass-separator for the implantation of the ion beams of selected stable isotopes of different elements into a tantalum foil placed inside the Faraday cup in the focal plane of the mass-separator. The amount of implanted ions has been measured with a high accuracy by the current integrator connected to the Faraday cup. After the implantation of needed a...

  16. Inverse modeling of the Chernobyl source term using atmospheric concentration and deposition measurements

    Evangeliou, Nikolaos; Hamburger, Thomas; Cozic, Anne; Balkanski, Yves; Stohl, Andreas

    2017-07-01

    This paper describes the results of an inverse modeling study for the determination of the source term of the radionuclides 134Cs, 137Cs and 131I released after the Chernobyl accident. The accident occurred on 26 April 1986 in the Former Soviet Union and released about 1019 Bq of radioactive materials that were transported as far away as the USA and Japan. Thereafter, several attempts to assess the magnitude of the emissions were made that were based on the knowledge of the core inventory and the levels of the spent fuel. More recently, when modeling tools were further developed, inverse modeling techniques were applied to the Chernobyl case for source term quantification. However, because radioactivity is a sensitive topic for the public and attracts a lot of attention, high-quality measurements, which are essential for inverse modeling, were not made available except for a few sparse activity concentration measurements far from the source and far from the main direction of the radioactive fallout. For the first time, we apply Bayesian inversion of the Chernobyl source term using not only activity concentrations but also deposition measurements from the most recent public data set. These observations refer to a data rescue attempt that started more than 10 years ago, with a final goal to provide available measurements to anyone interested. In regards to our inverse modeling results, emissions of 134Cs were estimated to be 80 PBq or 30-50 % higher than what was previously published. From the released amount of 134Cs, about 70 PBq were deposited all over Europe. Similar to 134Cs, emissions of 137Cs were estimated as 86 PBq, on the same order as previously reported results. Finally, 131I emissions of 1365 PBq were found, which are about 10 % less than the prior total releases. The inversion pushes the injection heights of the three radionuclides to higher altitudes (up to about 3 km) than previously assumed (≈ 2.2 km) in order to better match both concentration

  17. Inverse modeling of the Chernobyl source term using atmospheric concentration and deposition measurements

    N. Evangeliou

    2017-07-01

    Full Text Available This paper describes the results of an inverse modeling study for the determination of the source term of the radionuclides 134Cs, 137Cs and 131I released after the Chernobyl accident. The accident occurred on 26 April 1986 in the Former Soviet Union and released about 1019 Bq of radioactive materials that were transported as far away as the USA and Japan. Thereafter, several attempts to assess the magnitude of the emissions were made that were based on the knowledge of the core inventory and the levels of the spent fuel. More recently, when modeling tools were further developed, inverse modeling techniques were applied to the Chernobyl case for source term quantification. However, because radioactivity is a sensitive topic for the public and attracts a lot of attention, high-quality measurements, which are essential for inverse modeling, were not made available except for a few sparse activity concentration measurements far from the source and far from the main direction of the radioactive fallout. For the first time, we apply Bayesian inversion of the Chernobyl source term using not only activity concentrations but also deposition measurements from the most recent public data set. These observations refer to a data rescue attempt that started more than 10 years ago, with a final goal to provide available measurements to anyone interested. In regards to our inverse modeling results, emissions of 134Cs were estimated to be 80 PBq or 30–50 % higher than what was previously published. From the released amount of 134Cs, about 70 PBq were deposited all over Europe. Similar to 134Cs, emissions of 137Cs were estimated as 86 PBq, on the same order as previously reported results. Finally, 131I emissions of 1365 PBq were found, which are about 10 % less than the prior total releases. The inversion pushes the injection heights of the three radionuclides to higher altitudes (up to about 3 km than previously assumed (≈ 2.2 km in order

  18. (CH4)-C-14 Measurements in Greenland Ice: Investigating Last Glacial Termination CH4 Sources

    Petrenko, V. V.; Smith, A. M.; Brook, E. J.

    2009-01-01

    by direct cosmogenic C-14 production in ice. C-14 of CO was measured to better understand this process and correct the sample (CH4)-C-14. Corrected results suggest that wetland sources were likely responsible for the majority of the Younger Dryas-Preboreal CH4 rise.......The cause of a large increase of atmospheric methane concentration during the Younger Dryas-Preboreal abrupt climatic transition (similar to 11,600 years ago) has been the subject of much debate. The carbon-14 (C-14) content of methane ((CH4)-C-14) should distinguish between wetland and clathrate...... contributions to this increase. We present measurements of (CH4)-C-14 in glacial ice, targeting this transition, performed by using ice samples obtained from an ablation site in west Greenland. Measured (CH4)-C-14 values were higher than predicted under any scenario. Sample (CH4)-C-14 appears to be elevated...

  19. Measurement of minority carrier lifetime in silicon solar cells using an a. c. light source

    Nagpal, A.; Gupta, R.S.; Srivastava, G.P. (Delhi Univ., New Delhi (India). Dept. of Electronic Sciences); Jain, V.K. (Solid State Physics Lab., Delhi (India)); Chilana, G.S. (Delhi Univ. (India). Dept. of Physics and Astrophysics)

    1990-06-01

    A simple technique for the measurement of minority carriers lifetimes is proposed. It is based on the modification of the junction structure by the addition of a d.c. bias to the a.c. source. This always keeps the solar cell in the forward biased condition and also keeps it in the operating range. This method provides a direct measurement of minority carriers lifetimes. The lifetime is found to increase from 2.89 {mu}s at 30deg C to 4.55 {mu}s at 120deg C. The lifetime reduces to 1.45 {mu}s at liquid air temperature. Based on these lifetime measurements, the diffusion length of the carriers has also been calculated. (orig.).

  20. Resistive plate chamber neutron and gamma sensitivity measurement with a {sup 252}Cf source

    Abbrescia, M.; Altieri, S.; Baratti, V.; Barnaba, O.; Belli, G.; Bruno, G.; Colaleo, A.; DeVecchi, C.; Guida, R. E-mail: roberto.guida@pv.infn.it; Iaselli, G.; Imbres, E.; Loddo, F.; Maggi, M.; Marangelli, B.; Musitelli, G.; Nardo, R.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Ratti, S.; Riccardi, C.; Romano, F.; Torre, P.; Vicini, A.; Vitulo, P.; Volpe, F

    2003-06-21

    A bakelite double gap Resistive Plate Chamber (RPC), operating in avalanche mode, has been exposed to the radiation emitted from a {sup 252}Cf source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF{sub 2} scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63{+-}0.02)x10{sup -3} (average energy 2 MeV) and a gamma sensitivity of (14.0{+-}0.5)x10{sup -3} (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment.

  1. An experiment to measure the electron neutrino mass using a cryogenic tritium source

    Fackler, O.; Jeziorski, B.; Kolos, W.; Monkhorst, H.; Mugge, M.; Sticker, H.; Szalewicz, K.; White, R.M.; Woerner, R.

    1985-01-01

    An experiment has been performed to determine the electron neutrino mass with the precision of a few eV by measuring the tritium beta decay energy distribution near the endpoint. Key features of the experiment are a 2 eV resolution electrostatic spectrometer and a high-activity frozen tritium source. It is important that the source have electronic wavefunctions which can be accurately calculated. These calculations have been made for tritium and the HeT + daughter ion and allow determination of branching fractions to 0.1% and energy of the excited states to 0.1 eV. The excited final molecular state calculations and the experimental apparatus are discussed. 4 refs., 5 figs

  2. Contribution to the study of luminous sources for uranium isotope measurements by emission spectrometry

    Leichnam, J.P.; Capitini, R.

    1964-01-01

    After a brief summary of results obtained with different hollow cathode luminous sources, the reasons for which they cannot be more widely used are given: an insufficient luminosity when uranium oxides are used in the cathode hollow; the large amount of sample required when it is metallic; the impossibility of effecting a chemical purification of the sample. Electrode-less discharge tubes excited by high frequency whose qualities (luminosity, stability, rapidity of preparation starting from small amounts of sample in various chemical forms, in particular iron) satisfy the conditions laid down for the measurement of uranium 235 by interferometry are used. Tho production process for such lamps is given together with the method of excitation. Examples of recordings obtained with an interferometer of the 'HYPEAC' type and a small grating spectrometer give an idea of the spectral qualities of these sources. (authors) [fr

  3. A new ion source for fission-yield measurements of rare-earth isotopes

    Pilzer, E.H.; Engler, G.

    1987-01-01

    A new integrated target-ion source for fission-yield measurements of rare-earth isotopes has been developed for the Soreq on-line isotope separator (SOLIS). The source is heated by electron bombardment to a temperature of 2400 0 C and ionization takes place in a rhenium hot cavity. To overcome the problem of impurities which reduce the ionization efficiency, a ZrC disk was inserted in the cavity. Calculations show that because of its high thermionic emission, ZrC enhances ionization performance considerably. For example, in the presence of 10 -5 mbar of cesium impurity, the ionization efficiency of a rhenium hot cavity for the rare-earth terbium is 6%. However, with a ZrC disk, the efficiency increases to 97%. (orig.)

  4. Tropical forests are a net carbon source based on aboveground measurements of gain and loss

    Baccini, A.; Walker, W.; Carvalho, L.; Farina, M.; Sulla-Menashe, D.; Houghton, R. A.

    2017-10-01

    The carbon balance of tropical ecosystems remains uncertain, with top-down atmospheric studies suggesting an overall sink and bottom-up ecological approaches indicating a modest net source. Here we use 12 years (2003 to 2014) of MODIS pantropical satellite data to quantify net annual changes in the aboveground carbon density of tropical woody live vegetation, providing direct, measurement-based evidence that the world’s tropical forests are a net carbon source of 425.2 ± 92.0 teragrams of carbon per year (Tg C year-1). This net release of carbon consists of losses of 861.7 ± 80.2 Tg C year-1 and gains of 436.5 ± 31.0 Tg C year-1. Gains result from forest growth; losses result from deforestation and from reductions in carbon density within standing forests (degradation or disturbance), with the latter accounting for 68.9% of overall losses.

  5. Chemical characterization and source apportionment of submicron aerosols measured in Senegal during the 2015 SHADOW campaign

    Rivellini, Laura-Hélèna; Chiapello, Isabelle; Tison, Emmanuel; Fourmentin, Marc; Féron, Anaïs; Diallo, Aboubacry; N'Diaye, Thierno; Goloub, Philippe; Canonaco, Francesco; Prévôt, André Stephan Henry; Riffault, Véronique

    2017-09-01

    The present study offers the first chemical characterization of the submicron (PM1) fraction in western Africa at a high time resolution, thanks to collocated measurements of nonrefractory (NR) species with an Aerosol Chemical Speciation Monitor (ACSM), black carbon and iron concentrations derived from absorption coefficient measurements with a 7-wavelength Aethalometer, and total PM1 determined by a TEOM-FDMS (tapered element oscillating microbalance-filtered dynamic measurement system) for mass closure. The field campaign was carried out over 3 months (March to June 2015) as part of the SHADOW (SaHAran Dust Over West Africa) project at a coastal site located in the outskirts of the city of Mbour, Senegal. With an averaged mass concentration of 5.4 µg m-3, levels of NR PM1 in Mbour were 3 to 10 times lower than those generally measured in urban and suburban polluted environments. Nonetheless the first half of the observation period was marked by intense but short pollution events (NR PM1 concentrations higher than 15 µg m-3), sea breeze phenomena and Saharan desert dust outbreaks (PM10 up to 900 µg m-3). During the second half of the campaign, the sampling site was mainly under the influence of marine air masses. The air masses on days under continental and sea breeze influences were dominated by organics (36-40 %), whereas sulfate particles were predominant (40 %) for days under oceanic influence. Overall, measurements showed that about three-quarters of the total PM1 were explained by NR PM1, BC (black carbon) and Fe (a proxy for dust) concentrations, leaving approximately one-quarter for other refractory species. A mean value of 4.6 % for the Fe / PM1 ratio was obtained. Source apportionment of the organic fraction, using positive matrix factorization (PMF), highlighted the impact of local combustion sources, such as traffic and residential activities, which contribute on average to 52 % of the total organic fraction. A new organic aerosol (OA) source

  6. Measuring the fractal dimension of the seismic source through the high-frequency fall-off of source spectra

    Wu, Z.L.; Chen, Y.T.; Kim, S.G.

    1995-09-01

    Using the Wigner-distribution estimation, the high-frequency fall-off of source spectra was estimated. The technique was applied to the analysis of the source spectra of the July 22, 1994, Vladivostok M6.4 deep-focus earthquake and that of the July 22, 1994, Northern Japan Sea M5.7 deep-focus earthquake. It is shown that the high-frequency fall-off of the source spectra of these two earthquakes may be characterized by two parts. Between the first corner frequency f 1 and the second corner frequency f 2 , the high-frequency fall-off of the source spectra can be represented by f 5.0 : above f 2 , the high-frequency fall-off can be represented by f 1.4 . In the perspective of the fractal geometry of earthquake source, it seems that the deep-focus earthquakes under consideration may be characterized as being composed of some 'sub events'. On the other hand, each sub event has its complex structure. (author). 12 refs, 3 figs, 1 tab

  7. A measurement-based X-ray source model characterization for CT dosimetry computations.

    Sommerville, Mitchell; Poirier, Yannick; Tambasco, Mauro

    2015-11-08

    The purpose of this study was to show that the nominal peak tube voltage potential (kVp) and measured half-value layer (HVL) can be used to generate energy spectra and fluence profiles for characterizing a computed tomography (CT) X-ray source, and to validate the source model and an in-house kV X-ray dose computation algorithm (kVDoseCalc) for computing machine- and patient-specific CT dose. Spatial variation of the X-ray source spectra of a Philips Brilliance and a GE Optima Big Bore CT scanner were found by measuring the HVL along the direction of the internal bow-tie filter axes. Third-party software, Spektr, and the nominal kVp settings were used to generate the energy spectra. Beam fluence was calculated by dividing the integral product of the spectra and the in-air NIST mass-energy attenuation coefficients by in-air dose measurements along the filter axis. The authors found the optimal number of photons to seed in kVDoseCalc to achieve dose convergence. The Philips Brilliance beams were modeled for 90, 120, and 140 kVp tube settings. The GE Optima beams were modeled for 80, 100, 120, and 140 kVp tube settings. Relative doses measured using a Capintec Farmer-type ionization chamber (0.65 cc) placed in a cylindrical polymethyl methacrylate (PMMA) phantom and irradiated by the Philips Brilliance, were compared to those computed with kVDoseCalc. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima were measured using a (0.015 cc) PTW Freiburg ionization chamber and compared to computations from kVDoseCalc. The number of photons required to reduce the average statistical uncertainty in dose to measurement over all 12 PMMA phantom positions was found to be 1.44%, 1.47%, and 1.41% for 90, 120, and 140 kVp, respectively. The maximum percent difference between calculation and measurement for all energies, measurement positions, and phantoms was less than 3.50%. Thirty-five out of a total of 36 simulation conditions were

  8. A Statistical Framework for Microbial Source Attribution: Measuring Uncertainty in Host Transmission Events Inferred from Genetic Data (Part 2 of a 2 Part Report)

    Allen, J; Velsko, S

    2009-11-16

    This report explores the question of whether meaningful conclusions can be drawn regarding the transmission relationship between two microbial samples on the basis of differences observed between the two sample's respective genomes. Unlike similar forensic applications using human DNA, the rapid rate of microbial genome evolution combined with the dynamics of infectious disease require a shift in thinking on what it means for two samples to 'match' in support of a forensic hypothesis. Previous outbreaks for SARS-CoV, FMDV and HIV were examined to investigate the question of how microbial sequence data can be used to draw inferences that link two infected individuals by direct transmission. The results are counter intuitive with respect to human DNA forensic applications in that some genetic change rather than exact matching improve confidence in inferring direct transmission links, however, too much genetic change poses challenges, which can weaken confidence in inferred links. High rates of infection coupled with relatively weak selective pressure observed in the SARS-CoV and FMDV data lead to fairly low confidence for direct transmission links. Confidence values for forensic hypotheses increased when testing for the possibility that samples are separated by at most a few intermediate hosts. Moreover, the observed outbreak conditions support the potential to provide high confidence values for hypothesis that exclude direct transmission links. Transmission inferences are based on the total number of observed or inferred genetic changes separating two sequences rather than uniquely weighing the importance of any one genetic mismatch. Thus, inferences are surprisingly robust in the presence of sequencing errors provided the error rates are randomly distributed across all samples in the reference outbreak database and the novel sequence samples in question. When the number of observed nucleotide mutations are limited due to characteristics of the outbreak or the availability of only partial rather than whole genome sequencing, indel information was shown to have the potential to improve performance but only for select outbreak conditions. In examined HIV transmission cases, extended evolution proved to be the limiting factor in assigning high confidence to transmission links, however, the potential to correct for extended evolution not associated with transmission events is demonstrated. Outbreak specific conditions such as selective pressure (in the form of varying mutation rate), are shown to impact the strength of inference made and a Monte Carlo simulation tool is introduced, which is used to provide upper and lower bounds on the confidence values associated with a forensic hypothesis.

  9. Privacy Protection on Multiple Sensitive Attributes

    Li, Zhen; Ye, Xiaojun

    In recent years, a privacy model called k-anonymity has gained popularity in the microdata releasing. As the microdata may contain multiple sensitive attributes about an individual, the protection of multiple sensitive attributes has become an important problem. Different from the existing models of single sensitive attribute, extra associations among multiple sensitive attributes should be invested. Two kinds of disclosure scenarios may happen because of logical associations. The Q&S Diversity is checked to prevent the foregoing disclosure risks, with an α Requirement definition used to ensure the diversity requirement. At last, a two-step greedy generalization algorithm is used to carry out the multiple sensitive attributes processing which deal with quasi-identifiers and sensitive attributes respectively. We reduce the overall distortion by the measure of Masking SA.

  10. Phenomenology and Meaning Attribution

    John Paley. (2017). Phenomenology as Qualitative Research: A Critical Analysis of Meaning Attribution. ... basic philosophical nature of phenomenological meaning and inquiry, and that he not ... In keeping with the title of my book, Researching. Lived Experience ...... a quantitative social science that can make generalizing.

  11. Main designations and attributions

    2010-01-01

    The chapter presents the main designations and attributions of the LNMRI - Brazilian National Laboratory of Metrology of Ionizing Radiation, the Cooperative Center in Radiation Protection and Medical Preparations for Accidents with Radiation; the Treaty for fully banning of nuclear tests and the Regional Center for Training of IAEA

  12. Measures against illicit trafficking of nuclear material and radioactive sources in the Republic of Belarus

    Piotoukh, O.

    2001-01-01

    Full text: The Republic of Belarus strives to take an active part in international cooperation in the field of prevention and interception of illicit uses of nuclear material and radioactive sources through: multilateral international agreements and bilateral interagency treatments; information exchange within the IAEA Illicit Trafficking Database; participation in different international seminars, workshops, conferences including those under the IAEA auspices etc. Belarus is constantly improving regulatory, legal and technical aspects of activities aimed at: accounting, control and ensuring of physical protection of nuclear material and security of radioactive sources; exercising efficient control over their export and import; detecting cases of their illicit uses and illegal cross-border movements and informing of such cases through the IAEA Illicit Trafficking Database; developing and providing training opportunities for personnel. Through Resolution 'On Measures for Physical Protection of Nuclear Materials' issued by the Council of Ministers in 1993, Committee for Supervision of Industrial and Nuclear Safety (PROMATOMNADZOR) was appointed as the authority responsible for ensuring physical protection of nuclear materials and facilities. Through Resolution 'On Measures for Fulfillment of Provisions of the Non-Proliferation Treaty' issued by the Council of Ministers in 1993, Promatomnadzor was designated as the national competent authority responsible for the establishment and maintenance of the State System of Accounting and Control of nuclear material. The system accounts all the nuclear material meeting the criteria defined in the Safeguards Agreement with the IAEA. The system includes two levels: i.e. on-site accounting and control and state accounting and control exercised by Promatomnadzor. Apart from reporting to the Agency, the system also provides for national tasks being accomplished: control over uses of nuclear material, its physical protection, access

  13. Airborne remote sensing and in situ measurements of atmospheric CO2 to quantify point source emissions

    Krings, Thomas; Neininger, Bruno; Gerilowski, Konstantin; Krautwurst, Sven; Buchwitz, Michael; Burrows, John P.; Lindemann, Carsten; Ruhtz, Thomas; Schüttemeyer, Dirk; Bovensmann, Heinrich

    2018-02-01

    Reliable techniques to infer greenhouse gas emission rates from localised sources require accurate measurement and inversion approaches. In this study airborne remote sensing observations of CO2 by the MAMAP instrument and airborne in situ measurements are used to infer emission estimates of carbon dioxide released from a cluster of coal-fired power plants. The study area is complex due to sources being located in close proximity and overlapping associated carbon dioxide plumes. For the analysis of in situ data, a mass balance approach is described and applied, whereas for the remote sensing observations an inverse Gaussian plume model is used in addition to a mass balance technique. A comparison between methods shows that results for all methods agree within 10 % or better with uncertainties of 10 to 30 % for cases in which in situ measurements were made for the complete vertical plume extent. The computed emissions for individual power plants are in agreement with results derived from emission factors and energy production data for the time of the overflight.

  14. Industrial point source CO2 emission strength estimation with aircraft measurements and dispersion modelling.

    Carotenuto, Federico; Gualtieri, Giovanni; Miglietta, Franco; Riccio, Angelo; Toscano, Piero; Wohlfahrt, Georg; Gioli, Beniamino

    2018-02-22

    CO 2 remains the greenhouse gas that contributes most to anthropogenic global warming, and the evaluation of its emissions is of major interest to both research and regulatory purposes. Emission inventories generally provide quite reliable estimates of CO 2 emissions. However, because of intrinsic uncertainties associated with these estimates, it is of great importance to validate emission inventories against independent estimates. This paper describes an integrated approach combining aircraft measurements and a puff dispersion modelling framework by considering a CO 2 industrial point source, located in Biganos, France. CO 2 density measurements were obtained by applying the mass balance method, while CO 2 emission estimates were derived by implementing the CALMET/CALPUFF model chain. For the latter, three meteorological initializations were used: (i) WRF-modelled outputs initialized by ECMWF reanalyses; (ii) WRF-modelled outputs initialized by CFSR reanalyses and (iii) local in situ observations. Governmental inventorial data were used as reference for all applications. The strengths and weaknesses of the different approaches and how they affect emission estimation uncertainty were investigated. The mass balance based on aircraft measurements was quite succesful in capturing the point source emission strength (at worst with a 16% bias), while the accuracy of the dispersion modelling, markedly when using ECMWF initialization through the WRF model, was only slightly lower (estimation with an 18% bias). The analysis will help in highlighting some methodological best practices that can be used as guidelines for future experiments.

  15. Biosignal PI, an Affordable Open-Source ECG and Respiration Measurement System

    Farhad Abtahi

    2014-12-01

    Full Text Available Bioimedical pilot projects e.g., telemedicine, homecare, animal and human trials usually involve several physiological measurements. Technical development of these projects is time consuming and in particular costly. A versatile but affordable biosignal measurement platform can help to reduce time and risk while keeping the focus on the important goal and making an efficient use of resources. In this work, an affordable and open source platform for development of physiological signals is proposed. As a first step an 8–12 leads electrocardiogram (ECG and respiration monitoring system is developed. Chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 for patient safety. The result shows the potential of this platform as a base for prototyping compact, affordable, and medically safe measurement systems. Further work involves both hardware and software development to develop modules. These modules may require development of front-ends for other biosignals or just collect data wirelessly from different devices e.g., blood pressure, weight, bioimpedance spectrum, blood glucose, e.g., through Bluetooth. All design and development documents, files and source codes will be available for non-commercial use through project website, BiosignalPI.org.

  16. Crowd-sourcing as an analytical method: Metrology of smartphone measurements in heritage science.

    Brigham, Rosie; Grau-Bove, Josep; Rudnicka, Anna; Cassar, May; Strlic, Matija

    2018-04-12

    This research assesses the precision, repeatability and accuracy of crowd-sourced scientific measurements, and whether their quality is sufficient to provide usable results. Measurements of colour and area were chosen because of the possibility of producing them with smartphone cameras. The quality of measurements was estimated experimentally by comparing data contributed by anonymous participants in heritage sites with reference measurements of known accuracy and precision. Participants performed the measurements by taking photographs with their smartphones, from which colour and dimensional data could be extracted. The results indicate that smartphone measurements provided by citizen-scientists can be used to measure changes of colour, but that the performance is strongly dependent on the measured colour coordinate and ranges from a minimum detectable colour change or difference between colours of ΔE 3.1 to ΔE 17.2. The same method is able to measure areas when the difference in colour with the neighbouring areas is higher than ΔE 10. These results render the method useful in some heritage science contexts, but higher precision would be desirable: the human eye can detect differences as small as ΔE 2, and a light-fast pigment fades approximately ΔE 8 in its lifetime. There is scope for further research in the automatization of the post-processing of user contributions and the effect of contextual factors (such as detail in the instructions) in the quality of the raw data. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Situational awareness of hazards: Validation of multi-source radiation measurements

    Hultquist, C.; Cervone, G.

    2016-12-01

    Citizen-led movements producing scientific hazard data during disasters are increasingly common. After the Japanese earthquake-triggered tsunami in 2011, and the resulting radioactive releases at the damaged Fukushima Daiichi nuclear power plants, citizens monitored on-ground levels of radiation with innovative mobile devices built from off-the-shelf components. To date, the citizen-led SAFECAST project has recorded 50 million radiation measurements worldwide, with the majority of these measurements from Japan. The analysis of data which are multi-dimensional, not vetted, and provided from multiple devices presents big data challenges due to their volume, velocity, variety, and veracity. While the SAFECAST project produced massive open-source radiation measurements at specific coordinates and times, the reliability and validity of the overall data have not yet been assessed. The nuclear disaster provides a case for assessing the SAFECAST data with official aerial remote sensing radiation data jointly collected by the governments of the United States and Japan. A spatial and statistical assessment of SAFECAST requires several preprocessing steps. First, SAFECAST ionized radiation sensors collected data using different units of measure than the government data, and they had to be converted. Secondly, the normally occurring radiation and decay rates of Cesium from deposition surveys were used to properly compare measurements in space and time. Finally, the GPS located points were selected within overlapping extents at multiple spatial resolutions. Quantitative measures were used to assess the similarity and differences in the observed measurements. Radiation measurements from the same geographic extents show similar spatial variations and statistically significant correlations. The results suggest that actionable scientific data for disasters and emergencies can be inferred from non-traditional and not vetted data generated through citizen science projects. This

  18. Measurement of greenhouse gases (GHGs) and source apportionment in Bakersfield, CA during CALNEX 2010

    Guha, A.; Gentner, D. R.; Goldstein, A.; Provencal, R. A.; Gardner, A.; Calnex Bakersfield Science Team

    2010-12-01

    The California Global Warming Solutions Act 2006 creates a need to validate and improve the GHG inventory of the State, which has been largely based on activity and emission factor based estimates. As part of CALNEX 2010, we conducted measurements at the Bakersfield supersite of CO2, CH4, and N2O using fast response laser analyzers (LGR Inc.) to document the ambient mixing ratios of GHGs and analyze their major sources in the region, with an emphasis on understanding emissions of methane (CH4) and nitrous oxide (N2O). The site was located downwind of the urban center during the day and usually experienced a reversal of wind direction at night. Bakersfield is an urban area with heavy industrialization including petroleum refineries, oilfields, manufacturing, and cogeneration plants, all of which can be sources of the abovementioned GHGs. The site was close to a highway and potentially subject to vehicular CH4 and N2O emissions. Hence, CO and a broad variety of VOCs, which can serve as tracers (particularly for vehicle emissions), were included in the measurements to help with source apportionment. In addition to typical urban and industrial sources, Kern County is a rich agricultural region and includes a large number of cattle feedlots, dairies, settling ponds and landfills which are assumed to be some of the largest anthropogenic sources of methane in the State. Additionally, the agricultural industry uses significant amounts of fertilizers, which can lead to production of N2O from the soils along with emissions from controlled biomass burning of agricultural waste. The three GHGs studied show a strong diurnal pattern with concentrations building up in the night-time as the planetary boundary layer (PBL) becomes smaller and reversal in wind direction causes the site to become downwind of some GHG sources like landfills and feedlots. The mean background concentrations at the site (CNO2= 323 ppb; CCO2 = 390 ppm) during the day were consistent with those from the

  19. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  20. RF radiation measurement for the Advanced Photon Source (AS) personnel safety system

    Song, J.J.; Kim, J.; Otocki, R.; Zhou, J.

    1995-01-01

    The Advanced Photon Source (APS) booster and storage ring RF system consists of five 1-MW klystrons, four 5-cell cavities, and sixteen single-cell cavities. The RF power is distributed through many hundreds of feet of WR2300 waveguide with H-hybrids and circulators. In order to protect personnel from the danger of RF radiation due to loose flanges or other openings in the waveguide system, three detector systems were implemented: an RF radiation detector, a waveguide pressure switch, and a Radiax aperture detector (RAD). This paper describes RF radiation measurements on the WR 2300 waveguide system

  1. Simple emittance measurement of H- beams from a large plasma source

    Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T.

    1996-03-01

    An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the 'image' plane of the pepper-pot. Emittance of H - beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured. The normalized emittance (95%) of a 6 mA H - beam with emission current density of about 10 mA/cm 2 is ∼0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes. (author)

  2. POLICIES AND MEASURES FOR RENEWABLE ENERGY SOURCES AND ACHIEVEMENT OF TARGETS BY 2020 IN CROATIA

    Igor Raguzin

    2010-01-01

    Full Text Available This paper is considering set up a longer-term perspective and plan of actions for the development of renewable energy infrastructure in Croatia in accordance with the new Croatian Energy Sector Development Strategy. Overall target till the year 2020 has been calculated in accordance with effort sharing methodology used for Directive 2009/28/EC. The paper presents some main existing policies and measures for achieving this ambitious target, including feed-in tariffs, guarantees of origin, and greenhouse gas emissions taxation. It is addressed the necessity for creating enabling environment for promotion of renewable energy sources and gradually remove barriers for its stronger penetration on the energy market.

  3. PRISMA - a spectrometer for the measurement of coherent excitations on a pulsed spallation neutron source

    Andreani, C.; Cilloco, F.; Petrillo, C.; Sacchetti, F.; Windsor, C.G.

    1986-04-01

    The measurement of nuclear and magnetic excitation spectra from single crystal samples remains central to condensed matter physics. The requirements in terms of the range and resolution of the scattering vector Q and energy transfer h/2πω are reviewed and typical experiments with a well defined cross-section are chosen. The performance and limitations of existing instruments are reviewed. A design for a new spectrometer, PRISMA, to be installed on the UK spallation neutron source, ISIS, is presented. Its performance for chosen experiments is given in terms of the Q and h/2πω range covered in a single scan, the resolution and the count rate. (author)

  4. Mathematicians, Attributional Complexity, and Gender

    Stalder, Daniel R.

    Given indirect indications in sex role and soda! psychology research that mathematical-deductive reasoning may negatively relate to social acuity, Study 1 investigated whether mathematicians were less attributionally complex than nonmathematicians. Study 1 administered the Attributional Complexity Scale, a measure of social acuity, to female and male faculty members and graduate students in four Midwestern schools. Atlrihutional complexity (AC) is the ability and motivation to give complex explanations for behavior. Study 1 found a significant interaction between field and gender. Only among women did mathematicians score lower on AC. In addition, an established gender difference in AC (that women score higher than men) was present only among nonmathematicians. Studies 2 and 3 offered some preliminary support for the possibility that it is generally female students who score tow on AC who aspire to he mathematicians and for the underlying view that female students' perceived similarity to mathematicians can influence their vocational choices.

  5. Phased Array Noise Source Localization Measurements Made on a Williams International FJ44 Engine

    Podboy, Gary G.; Horvath, Csaba

    2010-01-01

    A 48-microphone planar phased array system was used to acquire noise source localization data on a full-scale Williams International FJ44 turbofan engine. Data were acquired with the array at three different locations relative to the engine, two on the side and one in front of the engine. At the two side locations the planar microphone array was parallel to the engine centerline; at the front location the array was perpendicular to the engine centerline. At each of the three locations, data were acquired at eleven different engine operating conditions ranging from engine idle to maximum (take off) speed. Data obtained with the array off to the side of the engine were spatially filtered to separate the inlet and nozzle noise. Tones occurring in the inlet and nozzle spectra were traced to the low and high speed spools within the engine. The phased array data indicate that the Inflow Control Device (ICD) used during this test was not acoustically transparent; instead, some of the noise emanating from the inlet reflected off of the inlet lip of the ICD. This reflection is a source of error for far field noise measurements made during the test. The data also indicate that a total temperature rake in the inlet of the engine is a source of fan noise.

  6. WormGender - Open-Source Software for Automatic Caenorhabditis elegans Sex Ratio Measurement.

    Marta K Labocha

    Full Text Available Fast and quantitative analysis of animal phenotypes is one of the major challenges of current biology. Here we report the WormGender open-source software, which is designed for accurate quantification of sex ratio in Caenorhabditis elegans. The software functions include, i automatic recognition and counting of adult hermaphrodites and males, ii a manual inspection feature that enables manual correction of errors, and iii flexibility to use new training images to optimize the software for different imaging conditions. We evaluated the performance of our software by comparing manual and automated assessment of sex ratio. Our data showed that the WormGender software provided overall accurate sex ratio measurements. We further demonstrated the usage of WormGender by quantifying the high incidence of male (him phenotype in 27 mutant strains. Mutants of nine genes (brc-1, C30G12.6, cep-1, coh-3, him-3, him-5, him-8, skr-1, unc-86 showed significant him phenotype. The WormGender is written in Java and can be installed and run on both Windows and Mac platforms. The source code is freely available together with a user manual and sample data at http://www.QuantWorm.org/. The source code and sample data are also available at http://dx.doi.org/10.6084/m9.figshare.1541248.

  7. Measurement error in mobile source air pollution exposure estimates due to residential mobility during pregnancy.

    Pennington, Audrey Flak; Strickland, Matthew J; Klein, Mitchel; Zhai, Xinxin; Russell, Armistead G; Hansen, Craig; Darrow, Lyndsey A

    2017-09-01

    Prenatal air pollution exposure is frequently estimated using maternal residential location at the time of delivery as a proxy for residence during pregnancy. We describe residential mobility during pregnancy among 19,951 children from the Kaiser Air Pollution and Pediatric Asthma Study, quantify measurement error in spatially resolved estimates of prenatal exposure to mobile source fine particulate matter (PM 2.5 ) due to ignoring this mobility, and simulate the impact of this error on estimates of epidemiologic associations. Two exposure estimates were compared, one calculated using complete residential histories during pregnancy (weighted average based on time spent at each address) and the second calculated using only residence at birth. Estimates were computed using annual averages of primary PM 2.5 from traffic emissions modeled using a Research LINE-source dispersion model for near-surface releases (RLINE) at 250 m resolution. In this cohort, 18.6% of children were born to mothers who moved at least once during pregnancy. Mobile source PM 2.5 exposure estimates calculated using complete residential histories during pregnancy and only residence at birth were highly correlated (r S >0.9). Simulations indicated that ignoring residential mobility resulted in modest bias of epidemiologic associations toward the null, but varied by maternal characteristics and prenatal exposure windows of interest (ranging from -2% to -10% bias).

  8. Salmonellosis outbreaks in the United States due to fresh produce: sources and potential intervention measures.

    Hanning, Irene B; Nutt, J D; Ricke, Steven C

    2009-01-01

    Foodborne Salmonella spp. is a leading cause of foodborne illness in the United States each year. Traditionally, most cases of salmonellosis were thought to originate from meat and poultry products. However, an increasing number of salmonellosis outbreaks are occurring as a result of contaminated produce. Several produce items specifically have been identified in outbreaks, and the ability of Salmonella to attach or internalize into vegetables and fruits may be factors that make these produce items more likely to be sources of Salmonella. In addition, environmental factors including contaminated water sources used to irrigate and wash produce crops have been implicated in a large number of outbreaks. Salmonella is carried by both domesticated and wild animals and can contaminate freshwater by direct or indirect contact. In some cases, direct contact of produce or seeds with contaminated manure or animal wastes can lead to contaminated crops. This review examines outbreaks of Salmonella due to contaminated produce, the potential sources of Salmonella, and possible control measures to prevent contamination of produce.

  9. Automated tune measurements in the Advanced Light Source storage ring using a LabVIEW application

    Hinkson, J.A.; Chin, M.; Kim, C.H.; Nishimura, H.

    1994-06-01

    Horizontal and vertical betatron tunes and the synchrotron tune are measured frequently during storage ring commissioning. The measurements are tedious and subject to human errors. Automating this kind of repetitive measurement is underway using LabVIEW for Windows, a software application supplied by National Instruments Corporation, that provides acquisition, graphing, and analysis of data as well as instrument control through the General Purpose Interface Bus (GPIB). We have added LabVIEW access to the Advanced Light Source (ALS) data base and control system. LabVIEW is a fast and efficient tool for accelerator commissioning and beam physics studies. Hardware used to perform tune measurements include a tracking generator (or a white noise generator), strip line electrodes for external ''citation of the beam, button monitors, and a spectrum analyzer. All three tunes are displayed simultaneously on the spectrum analyzer. Our program automatically identifies three tunes by applying and analyzing small variations and reports the results. This routine can be encapsulated in other applications, for instance, in a chromaticity measurement and correction program

  10. Experimental sources of variation in avian energetics: estimated basal metabolic rate decreases with successive measurements.

    Jacobs, Paul J; McKechnie, Andrew E

    2014-01-01

    Basal metabolic rate (BMR) is one of the most widely used metabolic variables in endotherm ecological and evolutionary physiology. Surprisingly few studies have investigated how BMR is influenced by experimental and analytical variables over and above the standardized conditions required for minimum normothermic resting metabolism. We tested whether avian BMR is affected by habituation to the conditions experienced during laboratory gas exchange measurements by measuring BMR five times in succession in budgerigars (Melopsittacus undulatus) housed under constant temperature and photoperiod. Both the magnitude and the variability of BMR decreased significantly with repeated measurements, from 0.410 ± 0.092 W (n = 9) during the first measurement to 0.285 ± 0.042 W (n = 9) during the fifth measurement. Thus, estimated BMR decreased by ∼30% within individuals solely on account of the number of times they had previously experienced the experimental conditions. The most likely explanation for these results is an attenuation with repeated exposure of the acute stress response induced by birds being handled and placed in respirometry chambers. Our data suggest that habituation to experimental conditions is potentially an important determinant of observed BMR, and this source of variation needs to be taken into account in future studies of metabolic variation among individuals, populations, and species.

  11. Design of a high order Campbelling mode measurement system using open source hardware

    Izarra, G. de [CEA, DEN,DER, Experimental Programs Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France); Elter, Zs. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); CEA, DEN,DER, Instrumentation, Sensors and Dosimetry Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France); Jammes, C. [CEA, DEN,DER, Instrumentation, Sensors and Dosimetry Laboratory, Cadarache F-13108 Saint-Paul-lez-Durance (France)

    2016-12-11

    This paper reviews a new real-time measurement instrument dedicated for online neutron monitoring with fission chambers in nuclear reactors. The instrument implements the higher order Campbelling methods and self-monitoring capabilities on an open source development board. The board includes an CPU/FPGA System on a Chip. The feasibility of the measurement instrument was tested both in laboratory with a signal generator and in the Minerve reactor. It is shown that the instrument provides reliable and robust count rate estimation over a wide reactor power range based on the third order statistics of the fission chamber signal. In addition, the system is able to identify whether the measured count rate change is due to the malfunction of the detector or due to the change in the neutron flux. The applied self-monitoring method is based on the spectral properties of the fission chamber signal. During the experimental verification, the considered malfunction was the change of the polarization voltage. - Highlights: • A new online High Order Campelling measurement system is proposed. • It includes a fission chamber failure detection system. • The complete architecture of the measurement system is given. • Test on reactor show its accuracy over a wide count rate range.

  12. Initial time-resolved particle beam profile measurements at the Advanced Photon Source

    Yang, B.X.; Lumpkin, A.H.

    1995-01-01

    The commissioning of the 7-GeV Advanced Photon Source (APS) storage ring began in early 1995. Characterization of the stored particle beam properties involved time-resolved transverse and longitudinal profile measurements using optical synchrotron radiation (OSR) monitors. Early results include the observation of the beam on a single turn, measurements of the transverse beam sizes after damping using a 100 μs integration time (σ x ∼ 150 ± 25 μm, σ γ ∼ 65 ± 25 μm, depending on vertical coupling), and measurement of the bunch length (σ τ ∼ 25 to 55 ps, depending on the charge per bunch). The results are consistent with specifications and predictions based on the 8.2 nm-rad natural emittance, the calculated lattice parameters, and vertical coupling less than 10%. The novel, single-element focusing mirror for the photon transport line and the dual-sweep streak camera techniques which allow turn-by-turn measurements will also be presented. The latter measurements are believed to be the first of their kind on a storage ring in the USA

  13. Measurement of the energy and power radiated by a pulsed blackbody x-ray source

    Chandler, Gordon Andrew; McDaniel, Dillon Heirman; Jorgenson, Roy E.; Warne, Larry Kevin; Dropinski, Steven Clark; Hanson, Donald L.; Johnson, William Arthur; York, Mathew William; Lewis, D.F.; Korde, R.; Haslett, C.L.; Wall, D.L.; Ruggles, Laurence E.; Ramirez, L.E.; Stygar, William A.; Porter, John Larry Jr.; McKenney, John Lee; Bryce, Edwin Anthony; Cuneo, Michael Edward; Torres, Jose A.; Mills, Jerry Alan; Leeper, Ramon Joe; McGurn, John Stephen; Fehl, David Lee; Spielman, R. B.; Pyle, John H.; Mazarakis, Michael Gerrassimos; Ives III, Harry Crockett; Seamen, Johann F.; Simpson, Walter W.

    2006-01-01

    We have developed a diagnostic system that measures the spectrally integrated (i.e. the total) energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP) diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38 x 38 square array of 10-(micro)m-diameter pinholes in a 50-(micro)m-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of ∼1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999)RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode's output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation) the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and--on every shot--provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects) of the sensitivity of an array-diode combination is presented

  14. Mapping dry-season tree transpiration of an oak woodland at the catchment scale, using object-attributes derived from satellite imagery and sap flow measurements

    Reyes-Acosta, J.L.; Lubczynski, M.

    2013-01-01

    Tree transpiration is an important plant-physiological process that influences the water cycle, thereby influencing ecosystems and even the quantity of available water resources. However, direct tree-transpiration measurements, particularly at large spatial scales, are still rare, due to the

  15. An update on measurements of helium-production reactions with a spallation neutron source

    Haight, R.C.; Bateman, F.B.; Chadwick, M.B.

    1995-01-01

    This report gives the status, updated since the last Research Coordination Meeting, of alpha-particle production cross sections, emission spectra and angular distributions which we are measuring at the spallation source of fast neutrons at the Los Alamos Meson Physics Facility (LAMPF). Detectors at angles of 30, 60, 90 and 135 degrees are used to identify alpha particles, measure their energy spectra, and indicate the time-of-flight, and hence the energy, of the neutrons inducing the reaction. The useful neutron energy ranges from less than 1 MeV to approximately 50 MeV for the present experimental setup. Targets under study at present include C, N, 0, 27 Al, Si, 51 V, 56 Fe, 59 CO, 58,60 Ni, 89 Y and 93 Nb. Data for 59 Co have been re-analyzed. The results illustrate the capabilities of the approach, agreement with literature values, and comparisons with nuclear reaction model calculations

  16. Measurement of spherical compound refractive X-ray lens at ANKA synchrotron radiation source

    Dudchik, Yu.I.; Simon, R.; Baumbach, T.

    2007-01-01

    Parameters of compound refractive X-ray lens were measured at ANKA synchrotron radiation source. The lens consists of 224 spherical concave epoxy microlenses formed inside glass capillary. The curvature radius of individual microlens is equal to 100 microns. Measured were: X-ray focal spot, lens focal length and gain in intensity. The energy of X-ray beam was equal to 12 keV and 14 keV. It is shown that when X-ray lens is used, the gain in intensity of the X-ray beam in some cases may exceed value of 100. Tested lens is suitable to focus X-rays into, at least, 2-microns in size spot. (authors)

  17. A heat source probe for measuring thermal conductivity in waste rock dumps

    Blackford, M.G.; Harries, J.R.

    1985-10-01

    The development and use of a heat source probe to measure the thermal conductivity of the material in a waste rock dump is described. The probe releases heat at a constant rate into the surrounding material and the resulting temperature rise is inversely related to the thermal conductivity. The probe was designed for use in holes in the dump which are lined with 50 mm i.d. polyethylene liners. The poor thermal contact between the probe and the liner and the unknown conductivity of the backfill material around the liner necessitated long heating and cooling times (>10 hours) to ensure that the thermal conductivity of the dump material was being measured. Temperature data acquired in the field were analysed by comparing them with temperatures calculated using a two-dimensional cylindrical model of the probe and surrounding material, and the heat transfer code HEATRAN

  18. White source gamma-ray production spectral measurement facilities in the USA

    Larson, D.C.; Dickens, J.K.; Nelson, R.O.; Wender, S.A.

    1991-01-01

    The two primary neutron sources for measuring gamma-ray production (GRP) cross sections for basic and applied work in the USA are the Oak Ridge Electron Linear Accelerator (ORELA) located at the Oak Ridge National Laboratory (ORNL) and the Weapons Neutron Research (WNR) facility located at the Los Alamos National Laboratory (LANL). ORELA is based on a 180-MeV electron linear accelerator, while the WNR facility uses the Los Alamos Meson Physics Facility 800 MeV proton beam to produce neutrons. The facilities collectively cover the neutron-energy range from thermal to over 700 MeV. The paper describes the present capabilities for GRP measurements at each facility. 18 refs

  19. Automatic device for measuring β-emitting sources: P.A.P.A. β-meters

    Colomer, J.; Valentin, M.

    1969-01-01

    The apparatus described is designed for measuring β-emitting elements by the absorption method; it is suitable for carrying out a large number of routine analyses. A mechanical device pushes an aluminium absorption set automatically between the source and the detector; the movement is programmed for cutting on and off by a transistorized electronic unit, with printing out and punching of the results on tape; then this can be mathematically processed by a computer (tracing of absorption spectra, extrapolation and calculation of the activity). The detector is either a β-probe or a proportional counter with a specially designed loop. For routine measurements, the accuracy obtained, with all corrections made, is from 5 to 8 per cent; the reproducibility is about 2 per cent. (authors) [fr

  20. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.