WorldWideScience

Sample records for soundproofing

  1. Development of a Soundproof Device for 950 Watt rated Portable ...

    African Journals Online (AJOL)

    The noise emanating from generators has adverse effects on our health. In view of this, this paper reports the development of soundproof device for 950Watt rated generators which are widely used portable generators. Performance evaluation of the soundproof device was carried out, and the sound pressure level of the ...

  2. Comparison Criteria and Performance Levels for Soundproofing Panels Made in Different Constructive Variants

    Directory of Open Access Journals (Sweden)

    Ana Gheorghe

    2013-09-01

    Full Text Available This paper presents an analysis of the performance lavels and comparison criteria for panels made from different soundproofing materials, in different constructive variants. Setting the performance level, on the basis of normative and regulatory documents, for soundproofing materials contained inside of noise reduction devices, is determined so that it can be defined, tested and established feasible technical solutions for sound absorbing protection, through a dissemination of obtained results as well for ensuring requirements for implementing the technology transfer for manufacturing.

  3. Development of a Soundproof Device for 950 Watt rated Portable ...

    African Journals Online (AJOL)

    Dr. N.A Musa

    ABSTRACT: The noise emanating from generators has adverse effects on ... soundproof device was carried out, and the sound pressure level of the ... Heat resistance rubber pipe and. 8. ... attached to the exhaust of the generator, respectively.

  4. Sound-proof Sandwich Panel Design via Metamaterial Concept

    Science.gov (United States)

    Sui, Ni

    Sandwich panels consisting of hollow core cells and two face-sheets bonded on both sides have been widely used as lightweight and strong structures in practical engineering applications, but with poor acoustic performance especially at low frequency regime. Basic sound-proof methods for the sandwich panel design are spontaneously categorized as sound insulation and sound absorption. Motivated by metamaterial concept, this dissertation presents two sandwich panel designs without sacrificing weight or size penalty: A lightweight yet sound-proof honeycomb acoustic metamateiral can be used as core material for honeycomb sandwich panels to block sound and break the mass law to realize minimum sound transmission; the other sandwich panel design is based on coupled Helmholtz resonators and can achieve perfect sound absorption without sound reflection. Based on the honeycomb sandwich panel, the mechanical properties of the honeycomb core structure were studied first. By incorporating a thin membrane on top of each honeycomb core, the traditional honeycomb core turns into honeycomb acoustic metamaterial. The basic theory for such kind of membrane-type acoustic metamaterial is demonstrated by a lumped model with infinite periodic oscillator system, and the negative dynamic effective mass density for clamped membrane is analyzed under the membrane resonance condition. Evanescent wave mode caused by negative dynamic effective mass density and impedance methods are utilized to interpret the physical phenomenon of honeycomb acoustic metamaterials at resonance. The honeycomb metamaterials can extraordinarily improve low-frequency sound transmission loss below the first resonant frequency of the membrane. The property of the membrane, the tension of the membrane and the numbers of attached membranes can impact the sound transmission loss, which are observed by numerical simulations and validated by experiments. The sandwich panel which incorporates the honeycomb metamateiral as

  5. Finite-element analysis of elastic sound-proof coupling thermal state

    Science.gov (United States)

    Tsyss, V. G.; Strokov, I. M.; Sergaeva, M. Yu

    2018-01-01

    The aim is in calculated determining of the elastic rubber-metal element thermal state of soundproof coupling ship shafting under variable influence during loads in time. Thermal coupling calculation is performed with finite element method using NX Simens software with Nastran solver. As a result of studies, the following results were obtained: - a volumetric picture of the temperature distribution over the array of the deformed coupling body is obtained; - time to reach steady-state thermal coupling mode has been determined; - dependences of maximum temperature and time to reach state on the established operation mode on rotation frequency and ambient temperature are determined. The findings prove the conclusion that usage of finite element analysis modern software can significantly speed up problem solving.

  6. SoundProof: A Smartphone Platform for Wireless Monitoring of Wildlife and Environment

    Science.gov (United States)

    Lukac, M.; Monibi, M.; Lane, M. L.; Howell, L.; Ramanathan, N.; Borker, A.; McKown, M.; Croll, D.; Terschy, B.

    2011-12-01

    We are developing an open-source, low-cost wildlife and environmental monitoring solution based on Android smartphones. Using a smartphone instead of a traditional microcontroller or single board computer has several advantages: smartphones are single integrated devices with multiple radios and a battery; they have a robust software interface which enables customization; and are field-tested by millions of users daily. Consequently, smartphones can improve the cost, configurability, and real-time access to data for environmental monitoring, ultimately replacing existing monitoring solutions which are proprietary, difficult to customize, expensive, and require labor-intensive maintenance. While smartphones can radically change environmental and wildlife monitoring, there are a number of technical challenges to address. We present our smartphone-based platform, SoundProof, discuss the challenges of building an autonomous system based on Android phones, and our ongoing efforts to enable environmental monitoring. Our system is built using robust off-the-shelf hardware and mature open-source software where available, to increase scalability and ease of installation. Key features include: * High-quality acoustic signal collection from external microphones to monitor wildlife populations. * Real-time data access, remote programming, and configuration of the field sensor via wireless cellular or WiFi channels, accessible from a website. * Waterproof packaging and solar charger setup for long-term field deployments. * Rich instrumentation of the end-to-end system to quickly identify and debug problems. * Supplementary mesh networking system with long-range wireless antennae to provide coverage when no cell network is available. We have deployed this system to monitor Rufous Crowned Sparrows on Anacapa Island, Chinese Crested Turns on the Matsu Islands in Taiwan, and Ashy Storm Petrels on South East Farallon Island. We have testbeds at two UC Natural Reserves to field

  7. Panels with low-Q-factor resonators with theoretically infinite sound-proofing ability at a single frequency

    Science.gov (United States)

    Lazarev, L. A.

    2015-07-01

    An infinite panel with two types of resonators regularly installed on it is theoretically considered. Each resonator is an air-filled cavity hermetically closed by a plate, which executes piston vibrations. The plate and air inside the cavity play the roles of mass and elasticity, respectively. Every other resonator is reversed. At a certain ratio between the parameters of the resonators at the tuning frequency of the entire system, the acoustic-pressure force that directly affects the panel can be fully compensated by the action forces of the resonators. In this case, the sound-proofing ability (transmission loss) tends to infinity. The presented calculations show that a complete transmission-loss effect can be achieved even with low- Q resonators.

  8. ENERGY CONSERVATION AND GRAVITY WAVES IN SOUND-PROOF TREATMENTS OF STELLAR INTERIORS. II. LAGRANGIAN CONSTRAINED ANALYSIS

    International Nuclear Information System (INIS)

    Vasil, Geoffrey M.; Lecoanet, Daniel; Brown, Benjamin P.; Zweibel, Ellen G.; Wood, Toby S.

    2013-01-01

    The speed of sound greatly exceeds typical flow velocities in many stellar and planetary interiors. To follow the slow evolution of subsonic motions, various sound-proof models attempt to remove fast acoustic waves while retaining stratified convection and buoyancy dynamics. In astrophysics, anelastic models typically receive the most attention in the class of sound-filtered stratified models. Generally, anelastic models remain valid in nearly adiabatically stratified regions like stellar convection zones, but may break down in strongly sub-adiabatic, stably stratified layers common in stellar radiative zones. However, studying stellar rotation, circulation, and dynamos requires understanding the complex coupling between convection and radiative zones, and this requires robust equations valid in both regimes. Here we extend the analysis of equation sets begun in Brown et al., which studied anelastic models, to two types of pseudo-incompressible models. This class of models has received attention in atmospheric applications, and more recently in studies of white-dwarf supernova progenitors. We demonstrate that one model conserves energy but the other does not. We use Lagrangian variational methods to extend the energy conserving model to a general equation of state, and dub the resulting equation set the generalized pseudo-incompressible (GPI) model. We show that the GPI equations suitably capture low-frequency phenomena in both convection and radiative zones in stars and other stratified systems, and we provide recommendations for converting low-Mach number codes to this equation set

  9. Auditory Processing Testing: In the Booth versus Outside the Booth.

    Science.gov (United States)

    Lucker, Jay R

    2017-09-01

    Many audiologists believe that auditory processing testing must be carried out in a soundproof booth. This expectation is especially a problem in places such as elementary schools. Research comparing pure-tone thresholds obtained in sound booths compared to quiet test environments outside of these booths does not support that belief. Auditory processing testing is generally carried out at above threshold levels, and therefore may be even less likely to require a soundproof booth. The present study was carried out to compare test results in soundproof booths versus quiet rooms. The purpose of this study was to determine whether auditory processing tests can be administered in a quiet test room rather than in the soundproof test suite. The outcomes would identify that audiologists can provide auditory processing testing for children under various test conditions including quiet rooms at their school. A battery of auditory processing tests was administered at a test level equivalent to 50 dB HL through headphones. The same equipment was used for testing in both locations. Twenty participants identified with normal hearing were included in this study, ten having no auditory processing concerns and ten exhibiting auditory processing problems. All participants underwent a battery of tests, both inside the test booth and outside the booth in a quiet room. Order of testing (inside versus outside) was counterbalanced. Participants were first determined to have normal hearing thresholds for tones and speech. Auditory processing tests were recorded and presented from an HP EliteBook laptop computer with noise-canceling headphones attached to a y-cord that not only presented the test stimuli to the participants but also allowed monitor headphones to be worn by the evaluator. The same equipment was used inside as well as outside the booth. No differences were found for each auditory processing measure as a function of the test setting or the order in which testing was done

  10. METHODOLOGY FOR DETERMINATION OF SOUND INSULATION OF APARTMENTS’ ENCLOSING STRUCTURES TO MEET NOISE PROTECTION REQUIREMENTS

    Directory of Open Access Journals (Sweden)

    Giyasov Botir Iminzhonovich

    2017-10-01

    Full Text Available Subject: an important task in the design of internal enclosing structures of apartments is the establishment of their required soundproofing ability. At present, there is no reliable method for determining the required sound insulation and in this regard internal enclosures are designed without proper justification for noise protection. Research objectives: development of a technique for determining the required sound insulation of apartment’s internal enclosures to ensure an acceptable noise regime in the apartments’ rooms under the action of intra-apartment noise sources. Materials and methods: the methodology was developed on the basis of a statistical method for noise calculation in the apartments, treated as systems of acoustically coupled proportionate rooms, and with the help of a computer program that implements this method. Results: the technique makes it possible to generate, with the use of computer technologies, a targeted selection of internal enclosures of the apartment to meet their soundproofing requirements. Conclusions: the technique proposed in the article can be used at the design stage of apartments when determining the required soundproofing of partitions and doors. Using this technique, it is possible to harmonize the sound insulation ratio of individual elements among themselves and thereby guarantee a selection of internal structures for their acoustic and economic efficiency.

  11. Soundproofed exhaust system; Gegen stoerenden Abgasschall. Akustik

    Energy Technology Data Exchange (ETDEWEB)

    Paul-Faerber, M.

    2008-03-15

    Acoustic emissions of heating systems are a nuisance, especially the humming noise of big heating boilers and cogeneration units. Noise reduction measures, e.g. with exhaust sound absorbers, should be considered already in the projecting stage. (orig.)

  12. Market Analysis of Soundproof and Noise Reduction Plate

    Directory of Open Access Journals (Sweden)

    Chang Heyu

    2017-01-01

    Full Text Available Since the reform and opening up, China has a booming economy development, transportation industry as an important part of the economic processes has made a considerable progress, and continue to promote the rapid economic development. At the end of 2012, China's highway mileage has reached 4.238 million km and highway mileage ranks first in the world. Transportation in promoting rapid economic development, but also brings the traffic noise which has a tremendous influence on residents’ daily life, and this influence has gradually deepening and widening, in this situation the production of noise reduction panel gradually emerged. In this paper, a noise barriers manufacturer’ business model in Beijing Daxing District and analyze existing data will be analyzed, it will give much guidance and reference for a new noise reduction factory. The study has shown that plant will target all levels of government departments in charge of roads and the property of management department of residence as our customer groups, increasing technological innovation and improving product quality to establish a more extensive business relationships, and gradually formed noise barriers market competitiveness.

  13. Kelder. Gerda Taljaard. Kaapstad: Tafelberg, 2012. 224 pp. ISBN ...

    African Journals Online (AJOL)

    There are. Benjamin's girlfriends—Elzette, the evil blonde skinny lawyer, and Martine, the goth with porcelain skin who plays jazz saxophone in her soundproof bathroom whilst standing on the toilet seat. One of Esmeralda's boyfriends is a butcher with massive sideburns. Another boyfriend is a professional big game hunter,.

  14. Speaking the Undead

    DEFF Research Database (Denmark)

    Christiansen, Steen Ledet

    2010-01-01

    the soundproof studio. With a minimum of gore or visual exploitation, Pontypool reveals how we have become immune to the frenzy of the visible - we no longer fear the image. Instead, for our post-literate society, language is the one thing we have no defense against. The zombie virus spreads through Pontypool...

  15. PERANCANGAN DAN IMPLEMENTASI SOUND LEVEL METER (SLM DALAM SKALA LABORATORIUM SEBAGAI ALAT UKUR INTENSITAS BUNYI

    Directory of Open Access Journals (Sweden)

    Jamaludin .

    2014-09-01

    Full Text Available Laboratory based research is the implementation of Wave Mechanics ( GM . In this physical peristtiwa will be examined on Wave Mechanics in measuring the intensity of sound . In order to determine the relevant SLM using a condenser mic as well as determine the level of noise in the sound of different frequencies in the laboratory scale . Tests carried out under conditions of sound intensity soundproof space and sound intensity comparison with SLM industrial design . In this study also compares the design of the SLM SLM Nor- 118 . So that the data obtained is the result of data collection we did the design of the SLM SLM Nor- 118 can be said to be relevant , but there is a difference is a difference of ± 5.0 % . And at a certain frequency when he would decline due to several internal and external factors . The conclusions drawn are in any retrieval of data must be in the soundproof room so that when the data collection is no factor that affects both external and internal.

  16. Handbook Of Noise And Vibration

    International Nuclear Information System (INIS)

    1995-12-01

    This book is about noise and vibration. The first chapter has explanations of noise such as basic of sound, influence of noise, assessment of noise, measurement of prevention of noise and technology, case of noise measurement and soundproof. The second chapter describes vibration with outline, theory of vibration, interpretation of vibration, measurement for reduction of vibration, case of design of protection against vibration. It deals with related regulation and method of measurement.

  17. Method and Apparatus of Measuring Velocity and Sound Attenuation Coefficient in Bulk Materials Based on the Analysis of the Structure of Sound-Insulation Materials on the Basis of Perlite

    Science.gov (United States)

    Kapranov, B. I.; Mashanov, A. P.

    2017-04-01

    This paper presents the results of research and describes the apparatus for measuring the acoustic characteristics of bulk materials. Ultrasound, it has passed through a layer of bulk material, is further passes through an air gap. The presence of air gap prevents from measuring tract mechanical contacts, but complicates the measurement technology Studies were conducted on the example of measuring the acoustic characteristics of the widely used perlite-based sound-proofing material.

  18. Research on soundproof properties of cylindrical shells of generalized phononic crystals

    Science.gov (United States)

    Liu, Ru; Shu, Haisheng; Wang, Xingguo

    2017-04-01

    Based on the previous studies, the concept of generalized phononic crystals (GPCs) is further introduced into the cylindrical shell structures in this paper. And a type of cylindrical shells of generalized phononic crystals (CS-GPCs) is constructed, the structural field and acoustic-structural coupled field of the composite cylindrical shells are examined respectively. For the structural field, the transfer matrix method of mechanical state vector is adopted to build the transfer matrix of radial waves propagating from inside to outside. For the acoustic-structural coupled field, the expressions of the acoustic transmission/reflection coefficients and the sound insulation of acoustic waves with the excitation of center line sound source are set up. And the acoustic transmission coefficient and the frequency response of sound insulation in this mode were numerical calculated. Furthermore, the theoretical analysis results are verified by using the method of combining the numerical calculation and finite element simulation. Finally, the effects of inner and outer fluid parameters on the transmission/reflection coefficients of CS-GPCs are analyzed in detail.

  19. Use of D8K's at the Arjuzanx lignite mine

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-01

    Gives a general account of the Arjuzanx opencast site, Landes, which supplies a 245 MW thermal power station. Describes the special use of Caterpillar machines: three D8's for loading out of dirt under the stacker at the rate of 2500 t/hour, over a maximum distance of 120 m and two D8H's with three D8K tractors, fitted with a special device for snaking the conveyor forward. The drivers' cabs are sound-proofed and air-conditioned.

  20. Aspectos económicos del aislamiento acústico

    Directory of Open Access Journals (Sweden)

    Amarilla, Beatriz C.

    1990-12-01

    Full Text Available The general objective of this study was to analyze the soundproofing/cost ratio with different building alternatives for interior walls and floors. This technical-economic study was divided into three parts: — Dividing walls (environmental noises — Floors (impact noises — Special Solutions (double walls, floating floors, etcetera The results show that in developing countries the most costly solutions are not always the best for housing, as far as soundproofing is concerned. A good knowledge of the economic aspects related to this matter allows obtaining a good quality at a moderate cost, which is a priority in this type of country.

    El objetivo general de este trabajo fue el de analizar el comportamiento de la relación costo-aislamiento acústico en soluciones constructivas alternativas para muros interiores y entrepisos. Este estudio técnico-económico comprende tres partes: * Muros divisorios (ruidos aéreos. * Entrepisos (ruidos de impacto. * Soluciones especiales (muros de doble hoja, pisos flotantes, etc. Se llega a la conclusión que, en los países en desarrollo, no siempre las mejores soluciones para la vivienda, desde el punto de vista acústico, son las de mayor costo. Conocer en profundidad los aspectos económicos de esta cuestión significa poder lograr una buena calidad con costos moderados, lo cual constituye una prioridad en este tipo de países.

  1. Development of Active Noise Control System for Quieting Transformer Noise

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bok Kyu; Song, Seik Young; Choi, Huo Yul [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Yun, Dae Hea; Lee, Hyuk Jae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1997-12-31

    The passive noise control technique made use of sound-absorbing or soundproofing materials, so it required a large area and high cost for installation and had a drawback of poor performance at low frequency. Compared to this, the Active Noise Control attenuates noise sound pressure by using secondary source which has same performance ay low-frequency. Furthermore, it is able to save space and expenses. - research on adaptive algorithms - evaluation of global attenuation of the control - computer simulation - real-time Active Noise Control System Hardware Implementation - ANC system setting in the noisy area.

  2. Estonia teater - helikindel ja sinine = Estonian National Opera - soundproof and blue / Urmas Oja

    Index Scriptorium Estoniae

    Oja, Urmas, 1981-2012

    2006-01-01

    Rahvusooperi Estonia maja teatritiiva interjööri renoveerimine. Sisekujundus: Juta Lember (kavandas ka uued valgustid), Aulo Padar (SAB Lember & Padar). Arhitekt Indrek Suigusaar (AB Pluss OÜ). Restaureerimistööd: KAR-Grupp. Projekt ja valmis 2005. Ill.: 8 värv. sisevaadet

  3. Sustainability or Bust: Malaysian Home Buyers’ Stated Preferences for Sus-Tainable Housing

    Directory of Open Access Journals (Sweden)

    Syahid A.

    2016-01-01

    Full Text Available The lack of data on sustainable home buying behaviour in developing countries such as Malaysia is due to the absence of sustainable housing itself. However, it is still possible to solicit home buyers for their stated preferences and quantify its effects on housing demand. In this study, a sample of 300 responses to a Discrete Choice Experiment (DCE on sustainable housing features was analysed using the “support.CEs” program. This study found that the addition of sustainable features; renewable energy generation, enhanced soundproofing and ventilation, energy saving features, and higher green area ratios significantly increase home buyer’s willingness to pay (WTP for sustainable housing.

  4. Photovoltaics - solar power stations. Prospects of a cutting edge technology

    International Nuclear Information System (INIS)

    Heidenreich, M.

    2002-01-01

    Photovoltaics is the sector of the future in this millennium. The process of human urbanization has led to a high demand for electricity; at the same time high-density urban settlement offers an enormous surface area that could be used for photovoltaic equipment. Such surfaces include rooftops, building facades, parking lots for automobiles, train stations and solar soundproofing walls. According to conservative estimates, Austria has sufficient surface area for a peak solar output of 4,000 MW. This would be sufficient to supply some 1.6 million households with electricity from unlimited solar energy. However, a tremendous marketing effort will be required in order to achieve generation on such a scale. (author)

  5. The reduction of noise from hydraulic equipments; La reduction du bruit provenant des equipements hydrauliques

    Energy Technology Data Exchange (ETDEWEB)

    Gential, R.

    1996-09-01

    Noise pollution from hydraulic equipments (bath filling, toilets taps, waste waters flow, vibrations, knocks in water pipes, dilatation clattering in heating pipes, hissing of heater taps etc..) are one of the principal causes of nuisance inside residential buildings. Solutions exist and consist in the replacement of old cocks and fittings, the use of soundproof clamps for pipes and noise absorbing supports for baths etc.. This paper summarizes the available modern equipments with a low-noise warranty (cocks and fittings, noise dampers, anti-backflow valves, pressure reducers) and the practical solutions for the modification of existing installations (increase of pipe diameters, reduction of pipe lengths, use of flexible fittings, hydraulic counterbalancing of water flows in heaters etc..). (J.S.)

  6. The Health Consequences of Industrial Noise and Methods for Protection

    Directory of Open Access Journals (Sweden)

    Hasan Cetin Ekerbicer

    2008-06-01

    Full Text Available Noise-induced hearing loss in the work-site is the most prevalent irreversible occupational disease in the industrialized or industrializing communities. Because noise-induced hearing loss is permanent, it is essential to apply any measure likely to reduce exposure. This includes reduction at the source (quieter machines and equipment or encasing them in sound-proof enclosures or the use of individual protective devices such as ear plugs and/or ear muffs. If reliance is placed on the latter, it is imperative to verify that their manufacturers' claims for effectiveness are valid and that exposed workers are using them properly at all times. [TAF Prev Med Bull 2008; 7(3.000: 261-264

  7. Vibroacoustic Modeling of Mechanically Coupled Structures: Artificial Spring Technique Applied to Light and Heavy Mediums

    Directory of Open Access Journals (Sweden)

    L. Cheng

    1996-01-01

    Full Text Available This article deals with the modeling of vibrating structures immersed in both light and heavy fluids, and possible applications to noise control problems and industrial vessels containing fluids. A theoretical approach, using artificial spring systems to characterize the mechanical coupling between substructures, is extended to include fluid loading. A structure consisting of a plate-ended cylindrical shell and its enclosed acoustic cavity is analyzed. After a brief description of the proposed technique, a number of numerical results are presented. The analysis addresses the following specific issues: the coupling between the plate and the shell; the coupling between the structure and the enclosure; the possibilities and difficulties regarding internal soundproofing through modifications of the joint connections; and the effects of fluid loading on the vibration of the structure.

  8. Low frequency seismic noise acquisition and analysis in the Homestake Mine with tunable monolithic horizontal sensors

    Science.gov (United States)

    Acernese, Fausto; De Rosa, Rosario; DeSalvo, Riccardo; Giordano, Gerardo; Harms, Jan; Mandic, Vuk; Sajeva, Angelo; Trancynger, Thomas; Barone, Fabrizio

    2010-04-01

    In this paper we describe the scientific data recorded along one month of data taking of two mechanical monolithic horizontal sensor prototypes located in a blind-ended (side) tunnel 2000 ft deep in the Homestake (South Dakota, USA) mine chosen to host the Deep Underground Science and Engineering Laboratory (DUSEL). The two mechanical monolithic sensors, developed at the University of Salerno, are placed, in thermally insulating enclosures, onto concrete slabs connected to the bedrock, and behind a sound-proofing wall. The main goal of this experiment is to characterize the Homestake site in the frequency band 10-4 - 30Hz and to estimate the level of Newtonian noise in a deep underegropund laboratory. The horizontal semidiurnal Earth tide and the Peterson's New Low Noise Model have been measured.

  9. Long term seismic noise acquisition and analysis in the Homestake mine with tunable monolithic sensors

    Science.gov (United States)

    Acernese, Fausto; De Rosa, Rosario; De Salvo, Riccardo; Giordano, Gerardo; Harms, Jan; Mandic, Vuk; Sajeva, Angelo; Trancynger, Thomas; Barone, Fabrizio

    2009-09-01

    In this paper we describe the scientific data recorded along one month of data taking of two mechanical monolithic horizontal sensor prototypes located in a blind-ended (side) tunnel 2000 ft deep in the Homestake (South Dakota, USA) mine chosen to host the Deep Underground Science and Engineering Laboratory (DUSEL). The two mechanical monolithic sensors, developed at the University of Salerno, are placed, in thermally insulating enclosures, onto concrete slabs connected to the bedrock, and behind a sound-proofing wall. The main goal of this experiment is to characterize the Homestake site in the frequency band 10-4 ÷ 30 H z and to estimate the level of Newtonian noise, providing also the necessary preliminary information to understand the feasibility of underground gravitational-wave interferometers sensitive at 1 H z and below.

  10. A lightweight low-frequency sound insulation membrane-type acoustic metamaterial

    Directory of Open Access Journals (Sweden)

    Kuan Lu

    2016-02-01

    Full Text Available A novel membrane-type acoustic metamaterial with a high sound transmission loss (STL at low frequencies (⩽500Hz was designed and the mechanisms were investigated by using negative mass density theory. This metamaterial’s structure is like a sandwich with a thin (thickness=0.25mm lightweight flexible rubber material within two layers of honeycomb cell plates. Negative mass density was demonstrated at frequencies below the first natural frequency, which results in the excellent low-frequency sound insulation. The effects of different structural parameters of the membrane on the sound-proofed performance at low frequencies were investigated by using finite element method (FEM. The numerical results show that, the STL can be modulated to higher value by changing the structural parameters, such as the membrane surface density, the unite cell film shape, and the membrane tension. The acoustic metamaterial proposed in this study could provide a potential application in the low-frequency noise insulation.

  11. Noise-proof bubbles to protect sea life

    International Nuclear Information System (INIS)

    Deboutte, G.

    2012-01-01

    The construction of wind turbines in shallow sea might jeopardize the life of mammals living nearby. The wave sound generated by each hammer impact to drive the pillars deep in the sea bottom can reach up to 200 decibels at 750 m away from the construction site. Repeated noises at this sound level is thought to be damaging for audition systems of sea mammals. The German authorities have launched a 4-year long program to find efficient technical solutions to damp sound waves. Various techniques have been tested in the Baltic sea and it appears that most techniques are efficient but some seem more relevant like the bubble curtain in which air bubbles generated around the site disturb the propagation of sound waves, or the balloon curtain in which air balloons plays the role of the bubbles, or the network of vertical pipes set around the construction site, or the sound-proofed sheath set around the pillar and hammer. (A.C.)

  12. A lightweight low-frequency sound insulation membrane-type acoustic metamaterial

    Science.gov (United States)

    Lu, Kuan; Wu, Jiu Hui; Guan, Dong; Gao, Nansha; Jing, Li

    2016-02-01

    A novel membrane-type acoustic metamaterial with a high sound transmission loss (STL) at low frequencies (⩽500Hz) was designed and the mechanisms were investigated by using negative mass density theory. This metamaterial's structure is like a sandwich with a thin (thickness=0.25mm) lightweight flexible rubber material within two layers of honeycomb cell plates. Negative mass density was demonstrated at frequencies below the first natural frequency, which results in the excellent low-frequency sound insulation. The effects of different structural parameters of the membrane on the sound-proofed performance at low frequencies were investigated by using finite element method (FEM). The numerical results show that, the STL can be modulated to higher value by changing the structural parameters, such as the membrane surface density, the unite cell film shape, and the membrane tension. The acoustic metamaterial proposed in this study could provide a potential application in the low-frequency noise insulation.

  13. Coherence between fluid-, solid- and airsound by shock-waves in clamped plumbing pipes. Zusammenhang zwischen Fluid-, Koerper- und Luftschall installierter Rohrleitungen bei Druckstoessen

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, H. (Kaiserslautern Univ. (Germany, F.R.). Lehrstuhl fuer Stroemungslehre); Willrich, G. (Kaiserslautern Univ. (Germany, F.R.). Fachbereich Maschinenwesen)

    1989-12-01

    On a test setup with which it will be possible to measure the statical and the dynamical fluid pressure simultaneously and also the acceleration of the pipe and the reflected sound within a soundproofed room, the fluid dynamic boundary conditions were adjusted so, that the Joukowsky-push was produced by the 'fast closure' of the valve and that no cavitation resulted by reflections. The height of the Joukowsky-push as well as the spectral composition of the shock pressure waves resulting from the Joukowsky-push, have been calculated exactly. Cavitations by reflection occur under realistic conditions on the selected pipe line configuration and so they do no permit an exact calculation of the shock pressure spectrum. By a comparison of the fluid spectrum, the impact sound spectrum and the sound spectrum on different pipe clamp distances it will be recognized that the impact sound modifies its spectral components but that the sound spectrum does not modify its composition which essentially refers to the impact sound spectrum. (orig./GL).

  14. PW-6ES gas turbine generator for Maglev linear motor car. Yamanashi rinia jikkensen daiichi hensei sharyo tosaiyo PW-6ES gas tabin hatsuden sochi

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T [JR Railway Technical Research Inst., Tokyo (Japan); Nakamura, S [Ebara Corp., Tokyo (Japan)

    1994-06-10

    A power generator is developed to be used as the auxiliary power source for the first carriage at the levitation type railway Yamanashi linear experimental line. The gas turbine generator is installed to supply power to the electric equipment on the carriage, and the power generating conditions are transmitted to the ground commanding room via on-board central control system for centralized controlling. An aircraft diversion type ST6 gas turbine and a high frequency light weight generator are combined for the gas turbine generator developed this time. Single reduction planetary gear is employed for the reduction gear which connects the two units directly, the gas turbine being connected to one side and the generator to the other side with no coupling. The output of the generator is 350kW, AC 455V, and 400Hz, and power is supplied to the electric devices on the carriage after having been converted to DC 600V. Aluminium is used to reduce the weights of the soundproof enclosure and exhaust dust shell plate. 1 fig., 1 tab.

  15. 'Stay friends...and keep your distance!'

    CERN Multimedia

    2002-01-01

    The third part of CERN's road safety campaign focuses on road users on two wheels.   Cyclists are just like pedestrians, only they travel somewhat faster and have to venture out among the cars. This makes them highly vulnerable. In the third part of CERN's road safety campaign we speak to a cyclist and motor-cyclist who is particularly aware of the dangers of the road. Daniel Valero walked away unscathed from an accident for which he was responsible. A few months on, he analyses the problems associated with two-wheeled transport. What criticisms do you have of car drivers? When riding a bike you always seem to take car drivers by surprise, as if they're not aware of your presence. The problem is that they sit inside a shell, their car, in conditions of ever-increasing comfort. Sound-proofing, car stereos and car-phones are leading to a general decline in car drivers' attention levels and they end up forgetting that other people use the road as well themselves, in particular cyclists. Cyclists also...

  16. EVALUACIÓN POST-OCUPACIÓN DEL PABELLÓN PROF. PABELLÓN ANTONIO FERNANDO RODRIGUES (UERJ DE LA SATISFACCIÓN DEL USUARIO

    Directory of Open Access Journals (Sweden)

    Jairo Ferreira Lopes de Farias

    2015-12-01

    Full Text Available Post Occupancy Evaluation defines the methods and techniques to characterize the strength and weaknesses of a constructed structure by considering the users satisfaction in meeting their needs during the course of its use. This evaluation records the findings of the POE of the Pavillon Prof. Antônio Fernando Rodrigues, Maracanã campus of the State University of Rio de Janeiro (UERJ, relative to the environmental quality from the satisfaction of users. Results of the evaluation of the degree of satisfaction of the users reveal a positive response towards artificial illumination, artificial ventilation, the temperature in winter and in summer and the natural illumination. In general it was found that users considered the building well lit, properly temperature controlled and of appropriate size, but needed better soundproofing. The analysis led to recommendations for improvements in comforts and functionality of this environment. These findings can contribute to the improvement for future projects, avoiding the repetition of inadequacies and the consequent dissatisfaction of users, and for better post-occupancy management. DOI: http://dx.doi.org/10.12957/sustinere.2015.20004

  17. Tunneling works. Tunnel koji

    Energy Technology Data Exchange (ETDEWEB)

    Higo, M [Hazam Gumi, Ltd., Tokyo (Japan)

    1991-10-25

    A mountain tunneling method for rock-beds used to be applied mainly to construction works in the mountains under few restrictions by environmental problems. However, construction works near residential sreas have been increasing. There are such enviromental problems due to tunneling works as vibration, noise, lowering of ground-water level, and influences on other structures. This report mainly describes the measurement examples of vibration and noise accompanied with blasting and the effects of the measures to lessen such influences. When the tunneling works for the railroad was carried out on the natural ground mainly composed of basalt, vibration of the test blasting was measured at three stations with piezoelectric accelerometers. Then, ordinary blasting, mutistage blasting, and ABM blasting methods were used properly besed on the above results, and only a few complaints were made. In the different works, normal noise and low-frequency sound were mesured at 22 stations around the pit mouth. As countermeasures for noise, sound-proof sheets, walls, and single and double doors were installed and foundto be effective. 1 ref., 6 figs., 1 tab.

  18. WOODEN FLOORING – BETWEEN PRESENT AND FUTURE

    Directory of Open Access Journals (Sweden)

    Ivan CISMARU

    2015-06-01

    Full Text Available The paper aims at presenting a systematization of the wood floors, both in terms of the areas of application, and in terms of the fastening solutions and structures in constructions. In this respect, an extensive bibliographic research was achieved, on the researchers’ preoccupations. Starting from the current situation and forecasting the future, from the point of view of the chances held by wooden flooring, in competition with other types of materials, we dare say the wooden flooring or the wood in combination with other materials are not likely to be eliminated from the “civil-engineering market”. The wood floors are likely to develop as an application, especially in the area of the “special floors”, specific to the indoor sports or social halls; and even for some industrial sectors, with strict operating conditions (elasticity, thermal insulation, soundproofing that cannot be provided by other types of materials or structures. Starting from this last observation, the paper also aims at submitting current opinions with respect to this type of floors, both in the light of the current databases and in the light of the future researches, to this end

  19. Perfect sound insulation property of reclaimed waste tire rubber

    Science.gov (United States)

    Ubaidillah, Harjana, Yahya, Iwan; Kristiani, Restu; Muqowi, Eki; Mazlan, Saiful Amri

    2016-03-01

    This article reports an experimental investigation of sound insulation and absorption performance of a materials made of reclaimed ground tire rubber which is known as un-recyclable thermoset. The bulk waste tire is processed using single step recycling methods namely high-pressure high-temperature sintering (HPHTS). The bulk waste tire is simply placed into a mold and then a pressure load of 3 tons and a heating temperature of 200°C are applied to the mold. The HPHTS conducted for an hour and then it is cooled in room temperature. The resulted product is then evaluated the acoustical properties namely sound transmission loss (STL) and sound absorption coefficient using B&K Tube Kit Type 4206-T based on ISO 10534-2, ASTM E1050 and ASTM E2611. The sound absorption coefficient is found about 0.04 until 0.08 while STL value ranges between 50 to 60 dB. The sound absorption values are found to be very low (<0.1), while the average STL is higher than other elastomeric matrix found in previous work. The reclaimed tire rubber through HPHTS technique gives good soundproof characteristic.

  20. Plate-type metamaterials for extremely broadband low-frequency sound insulation

    Science.gov (United States)

    Wang, Xiaopeng; Guo, Xinwei; Chen, Tianning; Yao, Ge

    2018-01-01

    A novel plate-type acoustic metamaterial with a high sound transmission loss (STL) in the low-frequency range ( ≤1000 Hz) is designed, theoretically proven and then experimentally verified. The thin plates with large modulus used in this paper mean that we do not need to apply tension to the plates, which is more applicable to practical engineering, the achievement of noise reduction is better and the installation of plates is more user-friendly than that of the membranes. The effects of different structural parameters of the plates on the sound-proofed performance at low-frequencies were also investigated by experiment and finite element method (FEM). The results showed that the STL can be modulated effectively and predictably using vibration theory by changing the structural parameters, such as the radius and thickness of the plate. Furthermore, using unit cells of different geometric sizes which are responsible for different frequency regions, the stacked panels with thickness ≤16 mm and weight ≤5 kg/m2 showed high STL below 2000 Hz. The acoustic metamaterial proposed in this study could provide a potential application in the low-frequency noise insulation.

  1. The development of the Athens Emotional States Inventory (AESI): collection, validation and automatic processing of emotionally loaded sentences.

    Science.gov (United States)

    Chaspari, Theodora; Soldatos, Constantin; Maragos, Petros

    2015-01-01

    The development of ecologically valid procedures for collecting reliable and unbiased emotional data towards computer interfaces with social and affective intelligence targeting patients with mental disorders. Following its development, presented with, the Athens Emotional States Inventory (AESI) proposes the design, recording and validation of an audiovisual database for five emotional states: anger, fear, joy, sadness and neutral. The items of the AESI consist of sentences each having content indicative of the corresponding emotion. Emotional content was assessed through a survey of 40 young participants with a questionnaire following the Latin square design. The emotional sentences that were correctly identified by 85% of the participants were recorded in a soundproof room with microphones and cameras. A preliminary validation of AESI is performed through automatic emotion recognition experiments from speech. The resulting database contains 696 recorded utterances in Greek language by 20 native speakers and has a total duration of approximately 28 min. Speech classification results yield accuracy up to 75.15% for automatically recognizing the emotions in AESI. These results indicate the usefulness of our approach for collecting emotional data with reliable content, balanced across classes and with reduced environmental variability.

  2. Deflection of resilient materials for reduction of floor impact sound.

    Science.gov (United States)

    Lee, Jung-Yoon; Kim, Jong-Mun

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.

  3. Result on speech perception after conversion from Spectra® to Freedom®.

    Science.gov (United States)

    Magalhães, Ana Tereza de Matos; Goffi-Gomez, Maria Valéria Schmidt; Hoshino, Ana Cristina; Tsuji, Robinson Koji; Bento, Ricardo Ferreira; Brito, Rubens

    2012-04-01

    New technology in the Freedom® speech processor for cochlear implants was developed to improve how incoming acoustic sound is processed; this applies not only for new users, but also for previous generations of cochlear implants. To identify the contribution of this technology-- the Nucleus 22®--on speech perception tests in silence and in noise, and on audiometric thresholds. A cross-sectional cohort study was undertaken. Seventeen patients were selected. The last map based on the Spectra® was revised and optimized before starting the tests. Troubleshooting was used to identify malfunction. To identify the contribution of the Freedom® technology for the Nucleus22®, auditory thresholds and speech perception tests were performed in free field in sound-proof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB) were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. Freedom® applied for the Nucleus22® showed a statistically significant difference in all speech perception tests and audiometric thresholds. The Freedom® technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22®.

  4. Video Tutorial of Continental Food

    Science.gov (United States)

    Nurani, A. S.; Juwaedah, A.; Mahmudatussa'adah, A.

    2018-02-01

    This research is motivated by the belief in the importance of media in a learning process. Media as an intermediary serves to focus on the attention of learners. Selection of appropriate learning media is very influential on the success of the delivery of information itself both in terms of cognitive, affective and skills. Continental food is a course that studies food that comes from Europe and is very complex. To reduce verbalism and provide more real learning, then the tutorial media is needed. Media tutorials that are audio visual can provide a more concrete learning experience. The purpose of this research is to develop tutorial media in the form of video. The method used is the development method with the stages of analyzing the learning objectives, creating a story board, validating the story board, revising the story board and making video tutorial media. The results show that the making of storyboards should be very thorough, and detailed in accordance with the learning objectives to reduce errors in video capture so as to save time, cost and effort. In video capturing, lighting, shooting angles, and soundproofing make an excellent contribution to the quality of tutorial video produced. In shooting should focus more on tools, materials, and processing. Video tutorials should be interactive and two-way.

  5. Silence is golden : keeping a lid on noise quiets opposition to oilpatch operations

    International Nuclear Information System (INIS)

    Macedo, R.

    2006-01-01

    Record levels of drilling activity have led to denser well spacings that are often close to residential areas. Many oil and gas operators are now investing in noise suppression technology in order to suppress public concern over noise levels. This article reviewed some new silencing technologies available to the oil and gas industry. Issues concerning permissible sound levels for remote facilities were discussed. Silencing equipment details were presented for turbine exhaust engines, turbo inlet systems, reciprocating engines, and specialty silencers for ventilation systems. Issues concerning acoustical systems and retrofits for existing buildings were also examined. It was noted that a new muffler has been acoustically engineered to provide engine exhaust noise removal along with an internal acoustic treatment to eliminate radiated noise from the muffler shell. The loudest noise source at a compression station is often the engine exhaust of large reciprocating engines. Various computer programs are now available that analyze noise, create models to predict noise levels in decibels for nearby residents, and help to engineer noise control plans. It was concluded that many of the new sound-proofing technologies for the walls and roofs of buildings and enclosures were developed during the design of new compression units built by TransCanada Pipeline on main pipelines across Canada. 2 figs

  6. Limiting hazardous noise exposure from noisy toys: simple, sticky solutions.

    Science.gov (United States)

    Weinreich, Heather M; Jabbour, Noel; Levine, Samuel; Yueh, Bevan

    2013-09-01

    To assess noise levels of toys from the Sight & Hearing Association (SHA) 2010 Noisy Toys List and evaluate the change in noise of these toys after covering the speakers with tape or glue. One Group Pretest-Posttest Design. SHA 2010 Toys List (n = 18) toys were tested at distances of 0 and 25 cm from sound source in a soundproof booth using a digital sound-level meter. The dBA level of sound produced by toy was obtained. Toys with speakers (n = 16) were tested before and after altering speakers with plastic packing tape or nontoxic glue. Mean noise level for non-taped toys at 0 and 25 cm was 107.6 dBA (SD ± 8.5) and 82.5 dBA (SD ± 8.8), respectively. With tape, there was a statistically significant decrease in noise level at 0 and 25 cm: 84.2 dBA and 68.2 dBA (P toys. However, there was no significant difference between tape or glue. Overall, altering the toy can significantly decrease the sound a child may experience when playing with toys. However, some toys, even after altering, still produce sound levels that may be considered dangerous. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Adaptive Wavelet Threshold Denoising Method for Machinery Sound Based on Improved Fruit Fly Optimization Algorithm

    Directory of Open Access Journals (Sweden)

    Jing Xu

    2016-07-01

    Full Text Available As the sound signal of a machine contains abundant information and is easy to measure, acoustic-based monitoring or diagnosis systems exhibit obvious superiority, especially in some extreme conditions. However, the sound directly collected from industrial field is always polluted. In order to eliminate noise components from machinery sound, a wavelet threshold denoising method optimized by an improved fruit fly optimization algorithm (WTD-IFOA is proposed in this paper. The sound is firstly decomposed by wavelet transform (WT to obtain coefficients of each level. As the wavelet threshold functions proposed by Donoho were discontinuous, many modified functions with continuous first and second order derivative were presented to realize adaptively denoising. However, the function-based denoising process is time-consuming and it is difficult to find optimal thresholds. To overcome these problems, fruit fly optimization algorithm (FOA was introduced to the process. Moreover, to avoid falling into local extremes, an improved fly distance range obeying normal distribution was proposed on the basis of original FOA. Then, sound signal of a motor was recorded in a soundproof laboratory, and Gauss white noise was added into the signal. The simulation results illustrated the effectiveness and superiority of the proposed approach by a comprehensive comparison among five typical methods. Finally, an industrial application on a shearer in coal mining working face was performed to demonstrate the practical effect.

  8. Electron spin resonance of particulate soot samples from automobiles to help environmental studies

    International Nuclear Information System (INIS)

    Yamanaka, C.; Matsuda, T.; Ikeya, M.

    2005-01-01

    The application of electron spin resonance (ESR) was studied for diesel soot samples and suspended particulate matter (SPM) from automobile engines. Soot samples or diesel exhaust particles (DEP) were recovered at various points: in the exhaust pipe of a diesel engine, at the dust sampler of a highway tunnel (standard DEP), on the soundproofing wall alongside a heavy traffic road, and on the filters of a dust sampler for SPM. The diesel soot samples apparently showed two ESR spectra: one was a broad spectrum at g=2.1 with a line width of ca. 80-120mT and the other was a sharp signal of a carbon radical at g=2.003 with a line width of 0.4mT. Annealing experiments with a DEP sample at 250 deg. C revealed drastic enhancement of the sharp ESR signal, which suggested a thermal process of carbonization of remnant organics. An oximetric study by ESR showed an enhancement of the broad signal in the diesel soot sample as well as in the sharp ESR signal. Therefore, the main part of the broad ESR signal would be attributed to carbon radicals, which form a different configuration, probably closely interacting aggregates. Enhancement of the sharp ESR signal was not observed in the standard DEP sample under vacuum condition, which suggested less adsorption sites on the surface of DEP samples

  9. Systematic assessment of noise amplitude generated by toys intended for young children.

    Science.gov (United States)

    Mahboubi, Hossein; Oliaei, Sepehr; Badran, Karam W; Ziai, Kasra; Chang, Janice; Zardouz, Shawn; Shahriari, Shawn; Djalilian, Hamid R

    2013-06-01

    To systematically evaluate the noise generated by toys targeted for children and to compare the results over the course of 4 consecutive holiday shopping seasons. Experimental study. Academic medical center. During 2008-2011, more than 200 toys marketed for children older than 6 months were screened for loudness. The toys with sound output of more than 80 dBA at speaker level were retested in a soundproof audiometry booth. The generated sound amplitude of each toy was measured at speaker level and at 30 cm away from the speaker. Ninety different toys were analyzed. The mean (SD) noise amplitude was 100 (8) dBA (range, 80-121 dBA) at the speaker level and 80 (11) dBA (range, 60-109 dBA) at 30 cm away from the speaker. Eighty-eight (98%) had more than an 85-dBA noise amplitude at speaker level, whereas 19 (26%) had more than an 85-dBA noise amplitude at a 30-cm distance. Only the mean noise amplitude at 30 cm significantly declined during the studied period (P toys specified for different age groups. Our findings demonstrate the persistence of extremely loud toys marketed for very young children. Acoustic trauma from toys remains a potential risk factor for noise-induced hearing loss in this age group, warranting promotion of public awareness and regulatory considerations for manufacture and marketing of toys.

  10. Acid reflux directly causes sleep disturbances in rat with chronic esophagitis.

    Science.gov (United States)

    Nakahara, Kenichi; Fujiwara, Yasuhiro; Tsukahara, Takuya; Yamagami, Hirokazu; Tanigawa, Tetsuya; Shiba, Masatsugu; Tominaga, Kazunari; Watanabe, Toshio; Urade, Yoshihiro; Arakawa, Tetsuo

    2014-01-01

    Gastroesophageal reflux disease (GERD) is strongly associated with sleep disturbances. Proton pump inhibitor (PPI) therapy improves subjective but not objective sleep parameters in patients with GERD. This study aimed to investigate the association between GERD and sleep, and the effect of PPI on sleep by using a rat model of chronic acid reflux esophagitis. Acid reflux esophagitis was induced by ligating the transitional region between the forestomach and the glandular portion and then wrapping the duodenum near the pylorus. Rats underwent surgery for implantation of electrodes for electroencephalogram and electromyogram recordings, and they were transferred to a soundproof recording chamber. Polygraphic recordings were scored by using 10-s epochs for wake, rapid eye movement sleep, and non-rapid eye movement (NREM) sleep. To examine the role of acid reflux, rats were subcutaneously administered a PPI, omeprazole, at a dose of 20 mg/kg once daily. Rats with reflux esophagitis presented with several erosions, ulcers, and mucosal thickening with basal hyperplasia and marked inflammatory infiltration. The reflux esophagitis group showed a 34.0% increase in wake (232.2±11.4 min and 173.3±7.4 min in the reflux esophagitis and control groups, respectively; preflux esophagitis, and this effect was not observed when the PPI was withdrawn. Acid reflux directly causes sleep disturbances in rats with chronic esophagitis.

  11. Association between community noise and adiposity in patients with cardiovascular disease

    Directory of Open Access Journals (Sweden)

    Angel M Dzhambov

    2017-01-01

    Full Text Available Introduction: This study aimed to explore the effect of community noise on body mass index (BMI and waist circumference (WC in patients with cardiovascular disease (CVD. Materials and Methods: A representative sample of 132 patients from three tertiary hospitals in the city of Plovdiv, Bulgaria was collected. Anthropometric measurements were linked to global noise annoyance (GNA based on different residential noise annoyances, day–evening–night (Lden, and nighttime (Lnight road traffic noise exposure. Noise map Lden and Lnight were determined at the living room and bedroom façades, respectively, and further corrected to indoor exposure based on the window-opening frequency and soundproofing insulation. Results and Discussion: Results showed that BMI and WC increased (non-significantly per 5 dB. The effect of indoor noise was stronger in comparison with that of outdoor noise. For indoor Lden, the effect was more pronounced in men, those with diabetes, family history of diabetes, high noise sensitivity, using solid fuel/gas for domestic heating/cooking, and living on the first floor. As regards indoor Lnight, its effect was more pronounced in those with low socioeconomic status, hearing loss, and using solid fuel/gas for domestic heating/cooking. GNA was associated with lower BMI and WC. Conclusion: Road traffic noise was associated with an increase in adiposity in some potentially vulnerable patients with CVD.

  12. Wheel liner design for improved sound and structural performances

    Science.gov (United States)

    Oltean, Alexandru; Diaconescu, Claudiu; Tabacu, Ştefan

    2017-10-01

    Vehicle noise is composed mainly of wheel-road noise and noise from the power unit. At low speeds power unit noise dominates while at high speeds wheel-road noise dominates as wheel-road noise level increases approximately logarithmically with speed. The wheel liner is designed as a component of the vehicle that has a multiple role. It has to prevent the dirt or water from the road surface that are engaged by the wheel to access the engine/front bay. Same time it has the important role to reduce perceived noised in the passenger’s compartment that comes from the wheel-road interaction. Progress in plastic injection moulding technology allowed for new structures to be developed - nonwoven materials in combination with a PP based carrier structure which benefits from a cell structure caused by MuCell injection moulding. The results are light parts with increased sound absorption performances. An adapted combination of materials and production processes can provide the solution for stiff yet soundproofing structures valued for modern vehicles. Sound absorption characteristics of materials used for wheel liners applications were reported in this study. Different polypropylene and polyester fibre-based thermally bonded nonwovens varying in weight and thickness were investigated. Having as a background the performances of the nonwoven material the microcellular structure was part of the analysis. Acoustical absorptive behaviour was explained by analysing the results obtained using the impedance tube and correlating with the knowledge of materials structure.

  13. Study on the living environment of semi-underground room with attached green house; Fusetsu onshitsu no aru hanchikashitsu no kyojusei ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Tsukayama, N [Ochanomizu University, Tokyo (Japan)

    1996-10-27

    In response to demand for the expansion of living space, the living environment of semi-underground room has been investigated. An attached green house (passive solar house) is adjacent to the semi-underground room. This is reinforced concrete construction, having flat type solar collector on its roof and lighting window in its north side. It does not have artificial air conditioners. Based on the measurements of daylight factor, artificial lighting is not required at the window in the daytime, but it is desirable to use daylight and artificial lighting together at the center. The performance of sound insulation depends on the high performance soundproof sash level. There is less daily temperature variation due to its large heat capacity, and less yearly temperature variation than the outside. By shielding the solar radiation, the insolation in the green house in summer can be restricted in the same as in winter. The insolation can be easily received in winter due to its large vertical intensity of solar radiation. The green house in the south side is useful for improving the living environment of semi-underground room. The temperature rise in the semi-underground room can be restricted by opening window in summer. It is desirable for the comfortable living to use artificial cooling to reduce the daytime temperature by 3 to 4{degree}C. In winter, it is comfortable to heat by 4 to 5{degree}C. 2 refs., 7 figs.

  14. Air barrier systems: Construction applications

    Energy Technology Data Exchange (ETDEWEB)

    Perrault, J.C

    1989-01-01

    An examination is presented of how ordinary building materials can be used in an innovative manner to design, detail, and construct effective air barrier systems for common types of walls. For residential construction, the air drywall approach uses the interior gypsum board as the main component of the wall air barrier system. Joints between the gypsum board and adjacent materials or assemblies are sealed by gaskets. In commercial construction, two different techniques are employed for using gypsum board as air barrier material: the accessible drywall and non-accessible drywall approaches. The former is similar to the air drywall approach except that high performance sealants are used instead of gaskets. In the latter approach, exterior drywall sheathing is the main component of the air barrier system; joints between boards are taped and joints between boards and other components are sealed using elastomeric membrane strips. For various types of commercial and institutional buildings, metal air barrier systems are widely used and include pre-engineered curtain walls or sheet metal walls. Masonry wall systems are regarded as still the most durable, fireproof, and soundproof wall type available but an effective air barrier system has typically been difficult to implement. Factory-made elastomeric membranes offer the potential to provide airtightness to masonry walls. These membranes are applied on the entire masonry wall surface and are used to make airtight connections with other building components. Two types of product are available: thermofusible and peel-and-stick membranes. 5 figs.

  15. Acid reflux directly causes sleep disturbances in rat with chronic esophagitis.

    Directory of Open Access Journals (Sweden)

    Kenichi Nakahara

    Full Text Available BACKGROUND & AIMS: Gastroesophageal reflux disease (GERD is strongly associated with sleep disturbances. Proton pump inhibitor (PPI therapy improves subjective but not objective sleep parameters in patients with GERD. This study aimed to investigate the association between GERD and sleep, and the effect of PPI on sleep by using a rat model of chronic acid reflux esophagitis. METHODS: Acid reflux esophagitis was induced by ligating the transitional region between the forestomach and the glandular portion and then wrapping the duodenum near the pylorus. Rats underwent surgery for implantation of electrodes for electroencephalogram and electromyogram recordings, and they were transferred to a soundproof recording chamber. Polygraphic recordings were scored by using 10-s epochs for wake, rapid eye movement sleep, and non-rapid eye movement (NREM sleep. To examine the role of acid reflux, rats were subcutaneously administered a PPI, omeprazole, at a dose of 20 mg/kg once daily. RESULTS: Rats with reflux esophagitis presented with several erosions, ulcers, and mucosal thickening with basal hyperplasia and marked inflammatory infiltration. The reflux esophagitis group showed a 34.0% increase in wake (232.2±11.4 min and 173.3±7.4 min in the reflux esophagitis and control groups, respectively; p<0.01 accompanied by a reduction in NREM sleep during light period, an increase in sleep fragmentation, and more frequent stage transitions. The use of omeprazole significantly improved sleep disturbances caused by reflux esophagitis, and this effect was not observed when the PPI was withdrawn. CONCLUSIONS: Acid reflux directly causes sleep disturbances in rats with chronic esophagitis.

  16. Automatic teleaudiometry: a low cost method to auditory screening

    Directory of Open Access Journals (Sweden)

    Campelo, Victor Eulálio Sousa

    2010-03-01

    Full Text Available Introduction: The auditory screening' benefits has been demonstrated, however these programs has been restricted to the big centers. Objectives: (a Developing a auditory screening method to distance; (b Testing its accuracy and comparing to the screening audiometry test (AV. Method: The teleaudiometry (TA, consists in a developed software, installed in a computer with phone TDH39. It was realized a study in series in 73 individuals between 17 and 50 years, being 57,%% of the female sex, they were randomly selected between patients and companions of the Hospital das Clínicas. Before were subjected to a symptom questionnaire and otoscopy, the individuals realized the tests of TA AV, with scanning in 20dB in the frequencies of 1,2 and 4kHz following the ASHA (1997 protocol and to the gold standard test of audiometry of pure tones in soundproof booth in aleatory order. Results: the TA has lasted average 125+11s and the AV 65+18s. 69 individuals (94,5% declaring to be found difficult or very easy to performing the TA and 61 (83,6% have considered easy or very easy the AV. The accuracy results of TA and AV were respectively: sensibility (86,7% / 86,7%, specificity (75,9%/ 72,4% and negative predictive value (95,7% / 95,5%, positive predictive value (48,1% / 55,2%. Conclusion: The teleaudiometry has showed a good option as an auditory screening method, presenting accuracy next to screening audiometry. In comparison with this method, the teleaudiometry has presented a similar sensibility, major specificity, negative predictive value and endurance time and, under positive predictive value.

  17. VALIDATION OF THE ASSR TEST THROUGH COMPLEMENTARY AUDIOLOGYICAL METHODS

    Directory of Open Access Journals (Sweden)

    C. Mârtu

    2016-04-01

    Full Text Available Introduction: Auditory Steady State Response (ASSR is an objective method for determining the auditive threshold, applicable and necessary especially in children. The test is extremely important for recommending cochlear implant in children. The aim of the study was to compare pure tone audiometry responses and auditory steady-state thresholds. Materials and method: The study was performed on a group including both patients with normal hearing and with hearing loss. The main inclusion criteria accepted only patients with normal otomicroscopic aspect, normal tympanogram, capable to respond to pure tone audiometry, and with ear conduction thresholds between 0 and 80 dB NHL. The patients with suppurative otic processes or ear malformations were excluded. The research protocol was followed, the tests being performed in soundproofed rooms, starting with pure tone audiometry followed, after a pause, by ASSR determinations at frequencies of 0.5, 1.2 and 4 KHz. The audiological instruments were provided by a single manufacturer. ASSR was recorded at least two times for both borderline intensities, namely the one defining the auditory threshold and the first no-response intensity. The recorded responses were stored in a database and further processed in Excel. Discussion: The differences observed between pure tone audiometry and ASSR thresholds are important at 500 Hz and insignificant at the other frequencies. When approaching the PTA-ASSR relation, whatever the main characteristic between the PTA and ASSR thresholds in one ear, the profile of the lines gap maintains the same shape on the opposite ear. Conclusions: ASSR is a confident objective test, maintaining attention to low frequencies, where some differences might occur.

  18. The Distribution and Environmental Impacts of Noise Pollution Sadouqi Martyr Yazd International Airport Using GIS

    Directory of Open Access Journals (Sweden)

    H Zarei Mahmoud Abadi

    2016-03-01

    Full Text Available Introduction: Persecutors of aircraft noise at an airport has a close relationship with the alternate of landing and take-off weight of the aircraft and operations planning during the night. Now aircraft that spill in Yazd airport and take-off of aircraft is of jet engines or so-turbofan mean that the resulting sound will be very high. Methods: In this descriptive, cross-sectional  measurement of noise from aircraft traffic noise measuring station 7,The completed questionnaires to assess the effects of noise pollution in Yazd International Airport and the surrounding noise sensitive areas in 2014 by a portable audio device measurement is done. Results: The most amount of noise caused by aircraft traffic in the airport area and in adjacent areas with average noise level 84.8 dB at station No. 5 Regional Airport, located south of the airport, with an average noise level which was 75.5 dB. The results of analysis of questionnaires showed that 75 percent of people living in residential areas around the airport are being harassed by aircraft noise. Results indicate that, sleep disorders, nervousness, stress and mental illness and interfere with speech, regardless of the priority of different factors in the study area, are of the highest impact of aircraft noise. Conclusion: Aircraft noise is the strongest negative environmental factors that affect employees and residents around Yazd International Airport and can be harmful to health. The noise for health personnel, particularly those of daily tasks, are daily exposed to aircraft intense noise , are highly undesirable. So, essentially preventive severe conditions such as mandatory use of protective devices and soundproof acoustic shortening service personnel are needed for these people.

  19. Cardiac autonomic regulation during exposure to auditory stimulation with classical baroque or heavy metal music of different intensities.

    Science.gov (United States)

    Amaral, Joice A T; Nogueira, Marcela L; Roque, Adriano L; Guida, Heraldo L; De Abreu, Luiz Carlos; Raimundo, Rodrigo Daminello; Vanderlei, Luiz Carlos M; Ribeiro, Vivian L; Ferreira, Celso; Valenti, Vitor E

    2014-03-01

    The effects of chronic music auditory stimulation on the cardiovascular system have been investigated in the literature. However, data regarding the acute effects of different styles of music on cardiac autonomic regulation are lacking. The literature has indicated that auditory stimulation with white noise above 50 dB induces cardiac responses. We aimed to evaluate the acute effects of classical baroque and heavy metal music of different intensities on cardiac autonomic regulation. The study was performed in 16 healthy men aged 18-25 years. All procedures were performed in the same soundproof room. We analyzed heart rate variability (HRV) in time (standard deviation of normal-to-normal R-R intervals [SDNN], root-mean square of differences [RMSSD] and percentage of adjacent NN intervals with a difference of duration greater than 50 ms [pNN50]) and frequency (low frequency [LF], high frequency [HF] and LF/HF ratio) domains. HRV was recorded at rest for 10 minutes. Subsequently, the volunteers were exposed to one of the two musical styles (classical baroque or heavy metal music) for five minutes through an earphone, followed by a five-minute period of rest, and then they were exposed to the other style for another five minutes. The subjects were exposed to three equivalent sound levels (60-70dB, 70-80dB and 80-90dB). The sequence of songs was randomized for each individual. Auditory stimulation with heavy metal music did not influence HRV indices in the time and frequency domains in the three equivalent sound level ranges. The same was observed with classical baroque musical auditory stimulation with the three equivalent sound level ranges. Musical auditory stimulation of different intensities did not influence cardiac autonomic regulation in men.

  20. Levels of vibration transmitted to the operator of the tractor equipped with front axle suspension

    Directory of Open Access Journals (Sweden)

    Daniele Pochi

    2013-09-01

    Full Text Available In recent years the comfort and the preservation of the health of the operators became central issues in the evolution of agricultural machinery and led to the introduction of devices aimed at improving working conditions. Thereby, for instance, the presence of air conditioner, soundproof cab and driver seat suspension became normal on agricultural tractors. The vibrations are one of the most complex issues to deal with, being determined by the characteristics and interaction of elements such as tyres, axles, mainframe, cab and seat suspension. In this respect, manufacturers are trying to improve their products, even integrating these elements with new devices such as the suspension on the front axle of the tractor, aimed at reducing the level of vibrations during the transfers at high speed. One of these underwent tests at CRA-ING. Since its purpose is to reduce the level of vibration transmitted to the driver, their measurements in different points of the tractor and in different operating conditions, were compared in order to evaluate the effectiveness of the device, expressed as time of exposure. The suspension system of the front axle is designed to absorb the oscillations (especially pitching determined by irregularities in the road surface, allowing an increased control of the vehicle at high speed, as demonstrated by the test results and confirmed by the driving impressions outlined by the operator. The action of the device under these conditions results in an increase of the exposure time, important fact because of the relevance of the road transfer operations of tractors with mounted implements or trailers to tow and of the tendency to increase the speed limit for the road tractors (in Germany were brought to 50 km h–1 for several years. The action just described is less evident with increasing irregularity of the road surface and with the decrease of the travel speed. Nevertheless, in such conditions, the device appears to

  1. Symbolic Analysis of Heart Rate Variability During Exposure to Musical Auditory Stimulation.

    Science.gov (United States)

    Vanderlei, Franciele Marques; de Abreu, Luiz Carlos; Garner, David Matthew; Valenti, Vitor Engrácia

    2016-01-01

    In recent years, the application of nonlinear methods for analysis of heart rate variability (HRV) has increased. However, studies on the influence of music on cardiac autonomic modulation in those circumstances are rare. The research team aimed to evaluate the acute effects on HRV of selected auditory stimulation by 2 musical styles, measuring the results using nonlinear methods of analysis: Shannon entropy, symbolic analysis, and correlation-dimension analysis. Prospective control study in which the volunteers were exposed to music and variables were compared between control (no auditory stimulation) and during exposure to music. All procedures were performed in a sound-proofed room at the Faculty of Science and Technology at São Paulo State University (UNESP), São Paulo, Brazil. Participants were 22 healthy female students, aged between 18 and 30 y. Prior to the actual intervention, the participants remained at rest for 20 min, and then they were exposed to one of the selected types of music, either classical baroque (64-84 dB) or heavy-metal (75-84 dB). Each musical session lasted a total of 5 min and 15 s. At a point occurring up to 1 wk after that day, the participants listened to the second type of music. The 2 types of music were delivered in a random sequence that depended on the group to which the participant was assigned. The study analyzed the following HRV indices through Shannon entropy; symbolic analysis-0V%, 1V%, 2LV%, and 2ULV%; and correlation-dimension analysis. During exposure to auditory stimulation by heavy-metal or classical baroque music, the study established no statistically significant variations regarding the indices for the Shannon entropy; the symbolic analysis-0V%, 1V%, and 2ULV%; and the correlation-dimension analysis. However, during heavy-metal music, the 2LV% index in the symbolic analysis was reduced compared with the controls. Auditory stimulation with the heavy-metal music reduced the parasympathetic modulation of HRV

  2. An examination of the effects of various noise on physiological sensibility responses by using human EEG

    International Nuclear Information System (INIS)

    Cho, W. H.; Lee, J. K.; Son, T. Y.; Hwang, S. H.; Choi, H.; Lee, M. S.

    2013-01-01

    This study investigated human stress levels based on electroencephalogram (EEG) data and carried out a subjective evaluation analysis about noise. Visual information is very important for finding human's emotional state. And relatively more previous works have been done than those using auditory stimulus. Since there are fewer previous works, we thought that using auditory stimulus is good choice for our study. Twelve human subjects were exposed to classic piano, ocean wave, army alarm, ambulance, and mosquito noises. We used two groups of comfortable and uncomfortable noises are to see the difference between the definitely different two groups to confirm usefulness of using this setting of experiment. EEG data were collected during the experimental session. The subjects were tested in a soundproof chamber and asked to minimize blinking, head movement, and swallowing during the experiment. The total time of the noise experiment included the time of the relaxation phase, during which the subjects relaxed in silence for 10 minutes. The relaxation phase was followed by a 20 -second noise exposure. The alpha band activities of the subjects were significantly decreased for the ambulance and mosquito noises, as it compared to the classic piano and ocean wave noises. The alpha band activities of the subjects decreased by 12.8 ± 2.3% for the ocean wave noise, decreased by 32.0 ± 5.4% for the army alarm noise, decreased by 34.5 ± 6.7% for the ambulance noise and decreased by 58.3 ± 9.1% for the mosquito noise compared to that of classic piano. On the other hand, their beta band activities were significantly increased for the ambulance and mosquito noises as it compared to classic piano and ocean wave. The beta band activities of the subjects increased by 7.9 ± 1.7% for the ocean wave noise, increased by 20.6 ± 5.3% for the army alarm noise, increased by 48.0 ± 7.5% for the ambulance noise and increased by 61.9 ± 11.2% for the mosquito noise, as it is compared to

  3. Insonorización en el aeropuerto de Hamburgo

    Directory of Open Access Journals (Sweden)

    Havemann, H. Konrad

    1963-04-01

    Full Text Available Airports, especially the older ones, are faced with the problem of sound intensity. At the time of their construction most of them were situated in sparesely inhabited zones. But the expansion of the urban radius of the large cities has extended the residential areas to the neighbourhood of the airports, and this has given rise to the problem of sound abatement since it is obviously necessary to reduce as far as possible the nuisance which excessive noise creates to the local population. To overcome one aspect of the problem, the construction of a soundproof hangar has been initiated at Hamburg, so that the noise which the engines make, during their warmingup period, can be controlled. The airliners will be inside this hanger during the period of tuning up, or warming up of the engines. The tests of this hangar, under working conditions, have proved satisfactory. The general structure is of prestressed concrete, with strong transversal portal frames. A number of accoustical plates have been supported from the roof, and they will act as sound absorbers. The exterior aspect of the building is original, showing a powerful design of strong lines.Los aeropuertos, particularmente los más antiguos, presentan actualmente el problema del ruido, ya que cuando se construyeron se hallaban enclavados en zonas apenas habitadas. La expansión y diario crecimiento del radio urbano de las grandes ciudades lleva los barrios residenciales a las inmediaciones de los aeropuertos y, con ello, aparece el problema de la insonorización, pues deben evitarse, o por lo menos atenuar, las molestias que los ruidos excesivos crean en las zonas de habitación. Para dar solución a este estado de cosas se ha emprendido, en Hamburgo, la construcción de un hangar de insonorización de los ruidos que los aparatos modernos hacen al poner sus motores en marcha. El tiempo de calentamiento de motores, espera, etc., lo pasará el aparato en marcha en el interior de este hangar. Los

  4. Perbedaan Pola Spektrum Frekuensi Suara Pengucapan Daftar Tutur Kata Bahasa Indonesia pada Anak dengan Geligi Protrusif (Kajian pada Anak Laki-Laki Umur 9 dan 12 Tahun

    Directory of Open Access Journals (Sweden)

    Rinaldi Budi Utomo

    2015-12-01

    persamaan grafik pola spektrum frekuensi suara. Anak laki-laki umur 9 tahun memiliki pola spektrum frekuensi suara lebih rendah dan datar daripada anak laki-laki umur 12 tahun Difference of Sound Frequency Spectrum Pattern of Pronunciation of Indonesian Speech List in Children with Protrusive Teeth (In 9-12 Year Old Male Children. Clarity of pronouncations for early detection of oral disorders in children has been standardized into an Indonesian speech list that is popularly spoken by primary school children, but it requires a clinical application to be used as a speech test tool lists. The purpose of this study is that the standardized Indonesian speech list can be applied clinically in the case of Angle Class I malocclusion with protrusive anterior teeth in male children aged 9 and 12 years. The list is expected to be used as a test tool for speech disorders by looking at the spectrum patterns of speech sound frequency using Readability Meter tool. The arrangement of Indonesian speech list that is popular at children in school age is a contribution to the development of early detection of cavum oris abnormalities that occur in children to ease and accelerate the determination of diagnosis. This study was conducted using analytical epidemiological method with cross sectional design; the subjects were observed one time. The subjects were 24 male children from Javanese ethnic; 12 of there were 9 years old and the other 12 were 12 years old with protrusive anterior teeth and overjet 3-4 mm. Both of the groups pronounced the Indonesian speech list containing the dominant sound frequency in malocclusion Angle class I protrusive variation in the form of words /bakteri/, /demokrasi/, /formulir/, /konveksi/, /limbah/, /nasional/, /ringkas/, /samudera/, /takjub/, /ventilasi/. The recording was directly conducted in a soundproof room through sound recorder program using flat microphones and sound processing mixer. Then, the dominant sound frequency (Hz and the display of

  5. An examination of the effects of various noise on physiological sensibility responses by using human EEG

    Energy Technology Data Exchange (ETDEWEB)

    Cho, W. H.; Lee, J. K.; Son, T. Y.; Hwang, S. H.; Choi, H. [Sungkyunkwan University, Suwon (Korea, Republic of); Lee, M. S. [Hyundai Motor Company, Hwaseong (Korea, Republic of)

    2013-12-15

    This study investigated human stress levels based on electroencephalogram (EEG) data and carried out a subjective evaluation analysis about noise. Visual information is very important for finding human's emotional state. And relatively more previous works have been done than those using auditory stimulus. Since there are fewer previous works, we thought that using auditory stimulus is good choice for our study. Twelve human subjects were exposed to classic piano, ocean wave, army alarm, ambulance, and mosquito noises. We used two groups of comfortable and uncomfortable noises are to see the difference between the definitely different two groups to confirm usefulness of using this setting of experiment. EEG data were collected during the experimental session. The subjects were tested in a soundproof chamber and asked to minimize blinking, head movement, and swallowing during the experiment. The total time of the noise experiment included the time of the relaxation phase, during which the subjects relaxed in silence for 10 minutes. The relaxation phase was followed by a 20 -second noise exposure. The alpha band activities of the subjects were significantly decreased for the ambulance and mosquito noises, as it compared to the classic piano and ocean wave noises. The alpha band activities of the subjects decreased by 12.8 ± 2.3% for the ocean wave noise, decreased by 32.0 ± 5.4% for the army alarm noise, decreased by 34.5 ± 6.7% for the ambulance noise and decreased by 58.3 ± 9.1% for the mosquito noise compared to that of classic piano. On the other hand, their beta band activities were significantly increased for the ambulance and mosquito noises as it compared to classic piano and ocean wave. The beta band activities of the subjects increased by 7.9 ± 1.7% for the ocean wave noise, increased by 20.6 ± 5.3% for the army alarm noise, increased by 48.0 ± 7.5% for the ambulance noise and increased by 61.9 ± 11.2% for the mosquito noise, as it is compared

  6. Nuevos materiales aislantes y de seguridad en la construcción

    Directory of Open Access Journals (Sweden)

    Rodríguez, G.

    1978-02-01

    Full Text Available After highlighting the importance of Construction and Public Works and the important role the chemical industry plays in improving the characteristics of traditional products, this article analyzes the qualities of new insulation and safety materials. Amongst these materials, the following deserve special mention: — Polyvinyl chloride, used in carpentry, water pipes, etc., because of its water-proof properties, good heat and acoustic insulation and practically non-existent maintenance expenses; — Polyethylene, used for water by-passes and sewers, because of tis lightness and non-inflammability; — Polyamides, used in locksmithing, because of its considerable mechanical properties and high rust resistance, etc.; — Polystyrene foam, used in different types of linings; — Polyester foam, used for sound-proofing and combined with lead it is used against vibrations; — Cellular glass pellets, with many properties; — Layered glass, with polyvinyl butyral layers: good shock resistance properties and also used for reducing solar energy transmission; — Polycarbonate, used in airspace investigations and as a safety material.

    En este artículo, después de resaltar la importancia de la Edificación y de las Obras Públicas, y del gran papel de la industria química en orden a mejorar las propiedades de los productos tradicionales, se analizan las cualidades de nuevos materiales aislantes y de seguridad. Entre estos materiales destacan: — El cloruro de polivinilo, usado en carpintería, tuberías para conducción de aguas, etc., por sus propiedades impermeabilizantes, buen aislamiento térmico y acústico y gastos de mantenimiento casi nulos. — El polietileno, utilizado para derivación de aguas y saneamiento por su ligereza e Ininflamabilidad. — Las poliamidas, utilizadas en cerrajería por sus propiedades mecánicas elevadas y alta resistencia a la corrosión, etc. — Espumas de poliestireno, empleadas

  7. Oral Contraceptives Attenuate Cardiac Autonomic Responses to Musical Auditory Stimulation: Pilot Study.

    Science.gov (United States)

    Milan, Réveni Carmem; Plassa, Bruna Oliveira; Guida, Heraldo Lorena; de Abreu, Luiz Carlos; Gomes, Rayana L; Garner, David M; Valenti, Vitor E

    2015-01-01

    The literature presents contradictory results regarding the effects of contraceptives on cardiac autonomic regulation. The research team aimed to evaluate the effects of musical auditory stimulation on cardiac autonomic regulation in women who use oral contraceptives. The research team designed a transversal observational pilot study. The setting was the Centro de Estudos do Sistema Nervoso Autônomo (CESNA) in the Departamento de Fonoaudiologia at the Universidade Estadual Paulista (UNESP) in Marília, SP, Brazil. Participants were 22 healthy nonathletic and nonsedentary females, all nonsmokers and aged between 18 and 27 y. Participants were divided into 2 groups: (1) 12 women who were not taking oral contraceptives, the control group; and (2) 10 women who were taking oral contraceptives, the oral contraceptive group. In the first stage, a rest control, the women sat with their earphones turned off for 20 min. After that period, the participants were exposed to 20 min of classical baroque music (ie, "Canon in D Major," Johann Pachelbel), at 63-84 dB. Measurements of the equivalent sound levels were conducted in a soundproof room, and the intervals between consecutive heartbeats (R-R intervals) were recorded, with a sampling rate of 1000 Hz. For calculation of the linear indices, the research team used software to perform an analysis of heart rate variability (HRV). Linear indices of HRV were analyzed in the time domain: (1) the standard deviation of normal-to-normal R-R intervals (SDNN), (2) the root-mean square of differences between adjacent normal R-R intervals in a time interval (RMSSD), and (3) the percentage of adjacent R-R intervals with a difference of duration greater than 50 ms (pNN50). The study also analyzed the frequency domain-low frequency (LF), high frequency (HF), and LF/HF ratio. For the control group, the musical auditory stimulation reduced (1) the SDNN from 52.2 ± 10 ms to 48.4 ± 16 ms (P = .0034); (2) the RMSSD from 45.8 ± 22 ms to 41.2

  8. Treinamento auditivo formal em idosos usuários de próteses auditivas Formal auditory training in elderly hearing aid users

    Directory of Open Access Journals (Sweden)

    Elisiane Crestani de Miranda

    2008-12-01

    Experiment Group underwent seven formal auditory training sessions, aiming at stimulating their hearing skills for hearing closing, memory, attention, background figure and binaural integration. The participants were assessed by three behavioral tests and one self assessment questionnaire. RESULTS: The elderly from the Experiment Group had significantly better performance in the assessments after auditory training in comparison to the Control Group. conclusion: the formal auditory training program in a soundproof booth, associated with the use of hearing aids, improves speech recognition performance and reduces the perception of auditory handicap for the elderly who use intra-canal hearing aids.

  9. Limiares de reconhecimento de sentenças no ruído, em campo livre: valores de referência para adultos normo-ouvintes Speech recognition thresholds in noisy areas: reference values for normal hearing adults

    Directory of Open Access Journals (Sweden)

    Marília Oliveira Henriques

    2008-04-01

    Full Text Available Nas clínicas de audiologia, as queixas de dificuldade de compreensão da fala em ambientes ruidosos são freqüentes, mesmo para indivíduos normo-ouvintes. Assim, o audiologista deve não só identificar uma perda auditiva, mas também analisar a compreensão da fala, em condições de comunicação próximas às encontradas no cotidiano. OBJETIVO: Determinar o valor de referência para os limiares de reconhecimento de sentenças no ruído, em campo livre, para indivíduos adultos normo-ouvintes. MATERIAL E MÉTODO: O experimento foi realizado nos anos de 2005 e 2006. Participaram da pesquisa 150 indivíduos adultos normo-ouvintes, com idade entre 18 e 64 anos, avaliados em cabine acusticamente tratada. Realizou-se a avaliação a partir da aplicação do teste Listas de Sentenças em Português. As listas de sentenças foram apresentadas em campo livre, na presença de um ruído competitivo, na intensidade fixa de 65 dB A. O ângulo de incidência de ambos os estímulos foi de 0º- 0º azimute. RESULTADOS E CONCLUSÃO: Os limiares de reconhecimento de sentenças em campo-livre foram obtidos na relação sinal-ruído de -8,14 dB A, sendo este o valor de referência para indivíduos normo-ouvintes.In audiology clinics, complaints about difficulties in speech recognition in noise environments are frequent, even for normal-hearing individuals. Thus, the audiologist must not only identify a hearing loss, but also analyze speech recognition, under noisy conditions similar to those found in our daily lives. AIM: Determine the reference value for the recognition of phrases under noisy conditions, in the free field, for adult normal hearing patients. MATERIALS AND METHODS: This study was carried out in 2005 and 2006. We had 150 adult normal hearing individuals participating, with ages between 18 and 64 years, assessed in a sound-proof booth. We evaluation was based on lists of phrases in Portuguese. The phrases lists were presented in the free field

  10. Resultados na percepção de fala após conversão do Spectra® para Freedom® Result on speech perception after conversion from Spectra® to Freedom®

    Directory of Open Access Journals (Sweden)

    Ana Tereza de Matos Magalhães

    2012-04-01

    was used to identify malfunction. To identify the contribution of the Freedom® technology for the Nucleus22®, auditory thresholds and speech perception tests were performed in free field in sound-proof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. RESULTS: Freedom® applied for the Nucleus22® showed a statistically significant difference in all speech perception tests and audiometric thresholds. CONCLUSION: The reedom® technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22®.

  11. Analisis Koefisien Absorpsi Bunyi Pada Komposit Penguat Serat Alam Dengan Menggunakan Alat Uji Tabung Impedansi 2 Microphone

    Directory of Open Access Journals (Sweden)

    Cok Istri Putri Kusuma Kencanawati

    2016-12-01

    Full Text Available Abstrak: Dalam perambatannya gelombang bunyi dapat di halangi dengan menggunakan suatu medium yang memiliki sifat-sifatkedap suara, sehingga energi yang ditransmisikan akan mampu dikurangi/dihambat oleh medium tersebut. Salah satumetode yang dapat dipergunakan untuk mengetahui kemampuan peredaman (koefisien absorpsi suatu mediumterhadap gelombang bunyi yang datang dapat diketahui dengan menggunakan Tabung Impedansi 2 Microphone.Sedangkan sebagai mediumnya adalah panel komposit. Mengingat dalam perkembangan ilmu bahan saat ini banyak digunakan komposit dengan penguat serat alam, dan salah satu sifat yang dikaji adalah sifat akustiknya. Kajian ini lebihmenitik beratkan sifat akustik komposit berpenguat serat alam, mengingat selama ini banyak serat alam yang terbuangpercuma menjadi limbahsehingga mencemari lingkungan. Jenis-jenis serat alam yang digunakan sebagai penguatantara lain : serat serabut kelapa, serat jerami, serat batang pisang, serat nenas, serat kapuk dan serat batang kelapasawit, sedangkan frekuensi pengukuran koefisien absorpsi terhadap medium ini berkisar anatra 200 hz sampai dengan1400 hz, dengan ketebalan spesiemn uji antara 2 mm sampai dengan 4 mmdengan menggunakan metode pengujianTabung impedansi 2 mikrophone, sesuai dengan standart ISO 10534-2:1998 and American Standart forTestingMaterials (ASTM E1050-98. Dalam kajian ini diperoleh kesimpulan bahwa pada frekuensi rendah koefisienabsorpsi bahan cukup tinggi antara 0,4 sampai dengan 0,6 dan kemampuan serap bunyi ini akan menurun denganmeningkatnya frekuensi, sedangkan pengaruh ketebalan bahan juga mempengaruhi sifat akustiknya.Kata kunci: komposit, serat alam, koefisien absorpsi, tabung impedansi Abstract: In the propagation of sound waves can be prevented by using a medium that has properties soundproofed, so that thetransmitted energy to be able to be reduced / inhibited by the medium. One method that can be used to determine theability of damping (absorption coefficient of a

  12. COLLABORATIVE RESEARCH: CONTINUOUS DYNAMIC GRID ADAPTATION IN A GLOBAL ATMOSPHERIC MODEL: APPLICATION AND REFINEMENT

    Energy Technology Data Exchange (ETDEWEB)

    Gutowski, William J.; Prusa, Joseph M.; Smolarkiewicz, Piotr K.

    2012-05-08

    demonstrated range of validity of soundproof models, showing that they are more broadly applicable than some had previously thought. Substantial testing of EULAG included application and extension of the Jablonowski-Williamson baroclinic wave test - an archetype of planetary weather - and further analysis of multi-scale interactions arising from collapse of temperature fronts in both the baroclinic wave test and simulations of the Held-Suarez idealized climate. These analyses revealed properties of atmospheric gravity waves not seen in previous work and further demonstrated the ability of EULAG to simulate realistic behavior over several orders of magnitude of length scales. Additional collaborative work enhanced capability for modeling atmospheric flows with adaptive moving meshes and demonstrated the ability of EULAG to move into petascale computing. 3b. CAM-EULAG Advances We have developed CAM-EULAG in collaboration with former project postdoc, now University of Cape Town Assistant Professor, Babatunde Abiodun. Initial study documented good model performance in aqua-planet simulations. In particular, we showed that the grid adaptivity (stretching) implemented in CAM-EULAG allows higher resolution in selected regions without causing anomalous behavior such as spurious wave reflection. We then used the stretched-grid version to analyze simulated extreme precipitation events in West Africa, comparing the precipitation and event environment with observed behavior. The model simulates fairly well the spatial scale and the interannual and intraseasonal variability of the extreme events, although its extreme precipitation intensity is weaker than observed. In addition, both observations and the simulations show possible forcing of extreme events by African easterly waves. 3c. Other Contributions Through our collaborations, we have made contributions to a wide range of outcomes. For research focused on terrestrial behavior, these have included (1) upwind schemes for gas dynamics