WorldWideScience

Sample records for sound localization acuity

  1. Sound localization in common vampire bats: Acuity and use of the binaural time cue by a small mammal

    Science.gov (United States)

    Heffner, Rickye S.; Koay, Gimseong; Heffner, Henry E.

    2015-01-01

    Passive sound-localization acuity and the ability to use binaural time and intensity cues were determined for the common vampire bat (Desmodus rotundus). The bats were tested using a conditioned suppression/avoidance procedure in which they drank defibrinated blood from a spout in the presence of sounds from their right, but stopped drinking (i.e., broke contact with the spout) whenever a sound came from their left, thereby avoiding a mild shock. The mean minimum audible angle for three bats for a 100-ms noise burst was 13.1°—within the range of thresholds for other bats and near the mean for mammals. Common vampire bats readily localized pure tones of 20 kHz and higher, indicating they could use interaural intensity-differences. They could also localize pure tones of 5 kHz and lower, thereby demonstrating the use of interaural time-differences, despite their very small maximum interaural distance of 60 μs. A comparison of the use of locus cues among mammals suggests several implications for the evolution of sound localization and its underlying anatomical and physiological mechanisms. PMID:25618037

  2. Color improves ‘visual’ acuity via sound

    Directory of Open Access Journals (Sweden)

    Shelly eLevy-Tzedek

    2014-11-01

    Full Text Available Visual-to-auditory sensory substitution devices (SSDs convey visual information via sound, with the primary goal of making visual information accessible to blind and visually impaired individuals. We developed the EyeMusic SSD, which transforms shape, location and color information into musical notes. We tested the 'visual' acuity of 23 individuals (13 blind and 10 blindfolded sighted on the Snellen tumbling-E test, with the EyeMusic. Participants were asked to determine the orientation of the letter ‘E’. The test was repeated twice: in one test, the letter ‘E’ was drawn with a single color (white, and in the other test, with two colors (red and white. In the latter case, the vertical line in the letter, when upright, was drawn in red, with the three horizontal lines drawn in white. We found no significant differences in performance between the blind and the sighted groups. We found a significant effect of the added color on the ‘visual’ acuity. The highest acuity participants reached in the monochromatic test was 20/800, whereas with the added color, acuity doubled to 20/400. We conclude that color improves 'visual' acuity via sound.

  3. Color improves “visual” acuity via sound

    OpenAIRE

    Levy-Tzedek, Shelly; Riemer, Dar; Amedi, Amir

    2014-01-01

    Visual-to-auditory sensory substitution devices (SSDs) convey visual information via sound, with the primary goal of making visual information accessible to blind and visually impaired individuals. We developed the EyeMusic SSD, which transforms shape, location, and color information into musical notes. We tested the “visual” acuity of 23 individuals (13 blind and 10 blindfolded sighted) on the Snellen tumbling-E test, with the EyeMusic. Participants were asked to determine the orientation of...

  4. Hearing in alpacas (Vicugna pacos): audiogram, localization acuity, and use of binaural locus cues.

    Science.gov (United States)

    Heffner, Rickye S; Koay, Gimseong; Heffner, Henry E

    2014-02-01

    Behavioral audiograms and sound localization abilities were determined for three alpacas (Vicugna pacos). Their hearing at a level of 60 dB sound pressure level (SPL) (re 20 μPa) extended from 40 Hz to 32.8 kHz, a range of 9.7 octaves. They were most sensitive at 8 kHz, with an average threshold of -0.5 dB SPL. The minimum audible angle around the midline for 100-ms broadband noise was 23°, indicating relatively poor localization acuity and potentially supporting the finding that animals with broad areas of best vision have poorer sound localization acuity. The alpacas were able to localize low-frequency pure tones, indicating that they can use the binaural phase cue, but they were unable to localize pure tones above the frequency of phase ambiguity, thus indicating complete inability to use the binaural intensity-difference cue. In contrast, the alpacas relied on their high-frequency hearing for pinna cues; they could discriminate front-back sound sources using 3-kHz high-pass noise, but not 3-kHz low-pass noise. These results are compared to those of other hoofed mammals and to mammals more generally.

  5. Local and non-local deficits in amblyopia: acuity and spatial interactions.

    Science.gov (United States)

    Bonneh, Yoram S; Sagi, Dov; Polat, Uri

    2004-12-01

    Amblyopic vision is thought to be limited by abnormal long-range spatial interactions, but their exact mode of action and relationship to the main amblyopic deficit in visual acuity is largely unknown. We studied this relationship in a group (N=59) of anisometropic (N=21) and strabismic (or combined, N=38) subjects, using (1) a single and multi-pattern (crowded) computerized static Tumbling-E test with scaled spacing of two pattern widths (TeVA), in addition to an optotype (ETDRS chart) acuity test (VA) and (2) contrast detection of Gabor patches with lateral flankers (lateral masking) along the horizontal and vertical axes as well as in collinear and parallel configurations. By correlating the different measures of visual acuity and contrast suppression, we found that (1) the VA of the strabismic subjects could be decomposed into two uncorrelated components measured in TeVA: acuity for isolated patterns and acuity reduction due to flanking patterns. The latter comprised over 60% of the VA magnitude, on the average and accounted for over 50% of its variance. In contrast, a slight reduction in acuity was found in the anisometropic subjects, and the acuity for a single pattern could account for 70% of the VA variance. (2) The lateral suppression (contrast threshold elevation) in a parallel configuration along the horizontal axis was correlated with the VA (R2=0.7), as well as with the crowding effect (TeVA elevation, R2=0.5) for the strabismic group. Some correlation with the VA was also found for the collinear configuration in the anisometropic group, but less suppression and no correlation were found for all the vertical configurations in all the groups. The results indicate the existence of a specific non-local component of the strabismic deficit, in addition to the local acuity deficit in all amblyopia types. This deficit might reflect long-range lateral inhibition, or alternatively, an inaccurate and scattered top-down attentional selection mechanism.

  6. Sound localization and occupational noise

    Directory of Open Access Journals (Sweden)

    Pedro de Lemos Menezes

    2014-02-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the effects of occupational noise on sound localization in different spatial planes and frequencies among normal hearing firefighters. METHOD: A total of 29 adults with pure-tone hearing thresholds below 25 dB took part in the study. The participants were divided into a group of 19 firefighters exposed to occupational noise and a control group of 10 adults who were not exposed to such noise. All subjects were assigned a sound localization task involving 117 stimuli from 13 sound sources that were spatially distributed in horizontal, vertical, midsagittal and transverse planes. The three stimuli, which were square waves with fundamental frequencies of 500, 2,000 and 4,000 Hz, were presented at a sound level of 70 dB and were randomly repeated three times from each sound source. The angle between the speaker's axis in the same plane was 45°, and the distance to the subject was 1 m. RESULT: The results demonstrate that the sound localization ability of the firefighters was significantly lower (p<0.01 than that of the control group. CONCLUSION: Exposure to occupational noise, even when not resulting in hearing loss, may lead to a diminished ability to locate a sound source.

  7. Numerical value biases sound localization.

    Science.gov (United States)

    Golob, Edward J; Lewald, Jörg; Getzmann, Stephan; Mock, Jeffrey R

    2017-12-08

    Speech recognition starts with representations of basic acoustic perceptual features and ends by categorizing the sound based on long-term memory for word meaning. However, little is known about whether the reverse pattern of lexical influences on basic perception can occur. We tested for a lexical influence on auditory spatial perception by having subjects make spatial judgments of number stimuli. Four experiments used pointing or left/right 2-alternative forced choice tasks to examine perceptual judgments of sound location as a function of digit magnitude (1-9). The main finding was that for stimuli presented near the median plane there was a linear left-to-right bias for localizing smaller-to-larger numbers. At lateral locations there was a central-eccentric location bias in the pointing task, and either a bias restricted to the smaller numbers (left side) or no significant number bias (right side). Prior number location also biased subsequent number judgments towards the opposite side. Findings support a lexical influence on auditory spatial perception, with a linear mapping near midline and more complex relations at lateral locations. Results may reflect coding of dedicated spatial channels, with two representing lateral positions in each hemispace, and the midline area represented by either their overlap or a separate third channel.

  8. Material sound source localization through headphones

    Science.gov (United States)

    Dunai, Larisa; Peris-Fajarnes, Guillermo; Lengua, Ismael Lengua; Montaña, Ignacio Tortajada

    2012-09-01

    In the present paper a study of sound localization is carried out, considering two different sounds emitted from different hit materials (wood and bongo) as well as a Delta sound. The motivation of this research is to study how humans localize sounds coming from different materials, with the purpose of a future implementation of the acoustic sounds with better localization features in navigation aid systems or training audio-games suited for blind people. Wood and bongo sounds are recorded after hitting two objects made of these materials. Afterwards, they are analysed and processed. On the other hand, the Delta sound (click) is generated by using the Adobe Audition software, considering a frequency of 44.1 kHz. All sounds are analysed and convolved with previously measured non-individual Head-Related Transfer Functions both for an anechoic environment and for an environment with reverberation. The First Choice method is used in this experiment. Subjects are asked to localize the source position of the sound listened through the headphones, by using a graphic user interface. The analyses of the recorded data reveal that no significant differences are obtained either when considering the nature of the sounds (wood, bongo, Delta) or their environmental context (with or without reverberation). The localization accuracies for the anechoic sounds are: wood 90.19%, bongo 92.96% and Delta sound 89.59%, whereas for the sounds with reverberation the results are: wood 90.59%, bongo 92.63% and Delta sound 90.91%. According to these data, we can conclude that even when considering the reverberation effect, the localization accuracy does not significantly increase.

  9. Numerical value biases sound localization

    OpenAIRE

    Golob, Edward J.; Lewald, Jörg; Getzmann, Stephan; Mock, Jeffrey R.

    2017-01-01

    Speech recognition starts with representations of basic acoustic perceptual features and ends by categorizing the sound based on long-term memory for word meaning. However, little is known about whether the reverse pattern of lexical influences on basic perception can occur. We tested for a lexical influence on auditory spatial perception by having subjects make spatial judgments of number stimuli. Four experiments used pointing or left/right 2-alternative forced choice tasks to examine perce...

  10. Sound localization under perturbed binaural hearing.

    NARCIS (Netherlands)

    Wanrooij, M.M. van; Opstal, A.J. van

    2007-01-01

    This paper reports on the acute effects of a monaural plug on directional hearing in the horizontal (azimuth) and vertical (elevation) planes of human listeners. Sound localization behavior was tested with rapid head-orienting responses toward brief high-pass filtered (>3 kHz; HP) and broadband

  11. Sound Localization Strategies in Three Predators

    DEFF Research Database (Denmark)

    Carr, Catherine E; Christensen-Dalsgaard, Jakob

    2015-01-01

    . Despite the similar organization of their auditory systems, archosaurs and lizards use different strategies for encoding the ITDs that underlie localization of sound in azimuth. Barn owls encode ITD information using a place map, which is composed of neurons serving as labeled lines tuned for preferred......In this paper, we compare some of the neural strategies for sound localization and encoding interaural time differences (ITDs) in three predatory species of Reptilia, alligators, barn owls and geckos. Birds and crocodilians are sister groups among the extant archosaurs, while geckos are lepidosaurs...... spatial locations, while geckos may use a meter strategy or population code composed of broadly sensitive neurons that represent ITD via changes in the firing rate....

  12. Second Sound for Heat Source Localization

    CERN Document Server

    Vennekate, Hannes; Uhrmacher, Michael; Quadt, Arnulf; Grosse-Knetter, Joern

    2011-01-01

    Defects on the surface of superconducting cavities can limit their accelerating gradient by localized heating. This results in a phase transition to the normal conduction state | a quench. A new application, involving Oscillating Superleak Transducers (OST) to locate such quench inducing heat spots on the surface of the cavities, has been developed by D. Hartill et al. at Cornell University in 2008. The OSTs enable the detection of heat transfer via second sound in super uid helium. This thesis presents new results on the analysis of their signal. Its behavior has been studied for dierent circumstances at setups at the University of Gottingen and at CERN. New approaches for an automated signal processing have been developed. Furthermore, a rst test setup for a single-cell Superconducting Proton Linac (SPL) cavity has been prepared. Recommendations of a better signal retrieving for its operation are presented.

  13. Sound source localization and segregation with internally coupled ears

    DEFF Research Database (Denmark)

    Bee, Mark A; Christensen-Dalsgaard, Jakob

    2016-01-01

    to their correct sources (sound source segregation). Here, we review anatomical, biophysical, neurophysiological, and behavioral studies aimed at identifying how the internally coupled ears of frogs contribute to sound source localization and segregation. Our review focuses on treefrogs in the genus Hyla......, as they are the most thoroughly studied frogs in terms of sound source localization and segregation. They also represent promising model systems for future work aimed at understanding better how internally coupled ears contribute to sound source localization and segregation. We conclude our review by enumerating...

  14. Sound localization in the presence of one or two distracters

    NARCIS (Netherlands)

    Langendijk, E.H.A.; Kistler, D.J.; Wightman, F.L

    2001-01-01

    Localizing a target sound can be a challenge when one or more distracter sounds are present at the same time. This study measured the effect of distracter position on target localization for one distracter (17 positions) and two distracters (21 combinations of 17 positions). Listeners were

  15. Spherical loudspeaker array for local active control of sound.

    Science.gov (United States)

    Rafaely, Boaz

    2009-05-01

    Active control of sound has been employed to reduce noise levels around listeners' head using destructive interference from noise-canceling sound sources. Recently, spherical loudspeaker arrays have been studied as multiple-channel sound sources, capable of generating sound fields with high complexity. In this paper, the potential use of a spherical loudspeaker array for local active control of sound is investigated. A theoretical analysis of the primary and secondary sound fields around a spherical sound source reveals that the natural quiet zones for the spherical source have a shell-shape. Using numerical optimization, quiet zones with other shapes are designed, showing potential for quiet zones with extents that are significantly larger than the well-known limit of a tenth of a wavelength for monopole sources. The paper presents several simulation examples showing quiet zones in various configurations.

  16. Learning to Localize Sound with a Lizard Ear Model

    DEFF Research Database (Denmark)

    Shaikh, Danish; Hallam, John; Christensen-Dalsgaard, Jakob

    The peripheral auditory system of a lizard is strongly directional in the azimuth plane due to the acoustical coupling of the animal's two eardrums. This feature by itself is insufficient to accurately localize sound as the extracted directional information cannot be directly mapped to the sound...

  17. Ambient Sound-Based Collaborative Localization of Indeterministic Devices

    NARCIS (Netherlands)

    Kamminga, Jacob Wilhelm; Le Viet Duc, L Duc; Havinga, Paul J.M.

    2016-01-01

    Localization is essential in wireless sensor networks. To our knowledge, no prior work has utilized low-cost devices for collaborative localization based on only ambient sound, without the support of local infrastructure. The reason may be the fact that most low-cost devices are indeterministic and

  18. How to generate a sound-localization map in fish

    Science.gov (United States)

    van Hemmen, J. Leo

    2015-03-01

    How sound localization is represented in the fish brain is a research field largely unbiased by theoretical analysis and computational modeling. Yet, there is experimental evidence that the axes of particle acceleration due to underwater sound are represented through a map in the midbrain of fish, e.g., in the torus semicircularis of the rainbow trout (Wubbels et al. 1997). How does such a map arise? Fish perceive pressure gradients by their three otolithic organs, each of which comprises a dense, calcareous, stone that is bathed in endolymph and attached to a sensory epithelium. In rainbow trout, the sensory epithelia of left and right utricle lie in the horizontal plane and consist of hair cells with equally distributed preferred orientations. We model the neuronal response of this system on the basis of Schuijf's vector detection hypothesis (Schuijf et al. 1975) and introduce a temporal spike code of sound direction, where optimality of hair cell orientation θj with respect to the acceleration direction θs is mapped onto spike phases via a von-Mises distribution. By learning to tune in to the earliest synchronized activity, nerve cells in the midbrain generate a map under the supervision of a locally excitatory, yet globally inhibitory visual teacher. Work done in collaboration with Daniel Begovic. Partially supported by BCCN - Munich.

  19. Development of the sound localization cues in cats

    Science.gov (United States)

    Tollin, Daniel J.

    2004-05-01

    Cats are a common model for developmental studies of the psychophysical and physiological mechanisms of sound localization. Yet, there are few studies on the development of the acoustical cues to location in cats. The magnitude of the three main cues, interaural differences in time (ITDs) and level (ILDs), and monaural spectral shape cues, vary with location in adults. However, the increasing interaural distance associated with a growing head and pinnae during development will result in cues that change continuously until maturation is complete. Here, we report measurements, in cats aged 1 week to adulthood, of the physical dimensions of the head and pinnae and the localization cues, computed from measurements of directional transfer functions. At 1 week, ILD depended little on azimuth for frequencies 10 dB) shift to lower frequencies, and the maximum ITD increases to nearly 370 μs. Changes in the cues are correlated with the increasing size of the head and pinnae. [Work supported by NIDCD DC05122.

  20. Spatial resolution limits for the localization of noise sources using direct sound mapping

    DEFF Research Database (Denmark)

    Comesana, D. Fernandez; Holland, K. R.; Fernandez Grande, Efren

    2016-01-01

    the relationship between spatial resolution, noise level and geometry. The proposed expressions are validated via simulations and experiments. It is shown that particle velocity mapping yields better results for identifying closely spaced sound sources than sound pressure or sound intensity, especially...... extensively been used for many years to locate sound sources. However, it is not yet well defined when two sources should be regarded as resolved by means of direct sound mapping. This paper derives the limits of the direct representation of sound pressure, particle velocity and sound intensity by exploring......One of the main challenges arising from noise and vibration problems is how to identify the areas of a device, machine or structure that produce significant acoustic excitation, i.e. the localization of main noise sources. The direct visualization of sound, in particular sound intensity, has...

  1. Heart Sound Localization and Reduction in Tracheal Sounds by Gabor Time-Frequency Masking

    OpenAIRE

    SAATCI, Esra; Akan, Aydın

    2018-01-01

    Background and aim: Respiratorysounds, i.e. tracheal and lung sounds, have been of great interest due to theirdiagnostic values as well as the potential of their use in the estimation ofthe respiratory dynamics (mainly airflow). Thus the aim of the study is topresent a new method to filter the heart sound interference from the trachealsounds. Materials and methods: Trachealsounds and airflow signals were collected by using an accelerometer from 10 healthysubjects. Tracheal sounds were then pr...

  2. Enhanced Soundings for Local Coupling Studies Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, Craig R [University at Albany, State University of New York; Santanello, Joseph A [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States); Gentine, Pierre [Columbia Univ., New York, NY (United States)

    2016-04-01

    This document presents initial analyses of the enhanced radiosonde observations obtained during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Enhanced Soundings for Local Coupling Studies Field Campaign (ESLCS), which took place at the ARM Southern Great Plains (SGP) Central Facility (CF) from June 15 to August 31, 2015. During ESLCS, routine 4-times-daily radiosonde measurements at the ARM-SGP CF were augmented on 12 days (June 18 and 29; July 11, 14, 19, and 26; August 15, 16, 21, 25, 26, and 27) with daytime 1-hourly radiosondes and 10-minute ‘trailer’ radiosondes every 3 hours. These 12 intensive operational period (IOP) days were selected on the basis of prior-day qualitative forecasts of potential land-atmosphere coupling strength. The campaign captured 2 dry soil convection advantage days (June 29 and July 14) and 10 atmospherically controlled days. Other noteworthy IOP events include: 2 soil dry-down sequences (July 11-14-19 and August 21-25-26), a 2-day clear-sky case (August 15-16), and the passing of Tropical Storm Bill (June 18). To date, the ESLCS data set constitutes the highest-temporal-resolution sampling of the evolution of the daytime planetary boundary layer (PBL) using radiosondes at the ARM-SGP. The data set is expected to contribute to: 1) improved understanding and modeling of the diurnal evolution of the PBL, particularly with regard to the role of local soil wetness, and (2) new insights into the appropriateness of current ARM-SGP CF thermodynamic sampling strategies.

  3. Sound

    CERN Document Server

    Robertson, William C

    2003-01-01

    Muddled about what makes music? Stuck on the study of harmonics? Dumbfounded by how sound gets around? Now you no longer have to struggle to teach concepts you really don t grasp yourself. Sound takes an intentionally light touch to help out all those adults science teachers, parents wanting to help with homework, home-schoolers seeking necessary scientific background to teach middle school physics with confidence. The book introduces sound waves and uses that model to explain sound-related occurrences. Starting with the basics of what causes sound and how it travels, you'll learn how musical instruments work, how sound waves add and subtract, how the human ear works, and even why you can sound like a Munchkin when you inhale helium. Sound is the fourth book in the award-winning Stop Faking It! Series, published by NSTA Press. Like the other popular volumes, it is written by irreverent educator Bill Robertson, who offers this Sound recommendation: One of the coolest activities is whacking a spinning metal rod...

  4. Visual acuity test

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003396.htm Visual acuity test To use the sharing features on this page, please enable JavaScript. The visual acuity test is used to determine the smallest ...

  5. Horizontal sound localization in cochlear implant users with a contralateral hearing aid.

    Science.gov (United States)

    Veugen, Lidwien C E; Hendrikse, Maartje M E; van Wanrooij, Marc M; Agterberg, Martijn J H; Chalupper, Josef; Mens, Lucas H M; Snik, Ad F M; John van Opstal, A

    2016-06-01

    Interaural differences in sound arrival time (ITD) and in level (ILD) enable us to localize sounds in the horizontal plane, and can support source segregation and speech understanding in noisy environments. It is uncertain whether these cues are also available to hearing-impaired listeners who are bimodally fitted, i.e. with a cochlear implant (CI) and a contralateral hearing aid (HA). Here, we assessed sound localization behavior of fourteen bimodal listeners, all using the same Phonak HA and an Advanced Bionics CI processor, matched with respect to loudness growth. We aimed to determine the availability and contribution of binaural (ILDs, temporal fine structure and envelope ITDs) and monaural (loudness, spectral) cues to horizontal sound localization in bimodal listeners, by systematically varying the frequency band, level and envelope of the stimuli. The sound bandwidth had a strong effect on the localization bias of bimodal listeners, although localization performance was typically poor for all conditions. Responses could be systematically changed by adjusting the frequency range of the stimulus, or by simply switching the HA and CI on and off. Localization responses were largely biased to one side, typically the CI side for broadband and high-pass filtered sounds, and occasionally to the HA side for low-pass filtered sounds. HA-aided thresholds better than 45 dB HL in the frequency range of the stimulus appeared to be a prerequisite, but not a guarantee, for the ability to indicate sound source direction. We argue that bimodal sound localization is likely based on ILD cues, even at frequencies below 1500 Hz for which the natural ILDs are small. These cues are typically perturbed in bimodal listeners, leading to a biased localization percept of sounds. The high accuracy of some listeners could result from a combination of sufficient spectral overlap and loudness balance in bimodal hearing. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Spike-timing-based computation in sound localization.

    Directory of Open Access Journals (Sweden)

    Dan F M Goodman

    2010-11-01

    Full Text Available Spike timing is precise in the auditory system and it has been argued that it conveys information about auditory stimuli, in particular about the location of a sound source. However, beyond simple time differences, the way in which neurons might extract this information is unclear and the potential computational advantages are unknown. The computational difficulty of this task for an animal is to locate the source of an unexpected sound from two monaural signals that are highly dependent on the unknown source signal. In neuron models consisting of spectro-temporal filtering and spiking nonlinearity, we found that the binaural structure induced by spatialized sounds is mapped to synchrony patterns that depend on source location rather than on source signal. Location-specific synchrony patterns would then result in the activation of location-specific assemblies of postsynaptic neurons. We designed a spiking neuron model which exploited this principle to locate a variety of sound sources in a virtual acoustic environment using measured human head-related transfer functions. The model was able to accurately estimate the location of previously unknown sounds in both azimuth and elevation (including front/back discrimination in a known acoustic environment. We found that multiple representations of different acoustic environments could coexist as sets of overlapping neural assemblies which could be associated with spatial locations by Hebbian learning. The model demonstrates the computational relevance of relative spike timing to extract spatial information about sources independently of the source signal.

  7. A SOUND SOURCE LOCALIZATION TECHNIQUE TO SUPPORT SEARCH AND RESCUE IN LOUD NOISE ENVIRONMENTS

    Science.gov (United States)

    Yoshinaga, Hiroshi; Mizutani, Koichi; Wakatsuki, Naoto

    At some sites of earthquakes and other disasters, rescuers search for people buried under rubble by listening for the sounds which they make. Thus developing a technique to localize sound sources amidst loud noise will support such search and rescue operations. In this paper, we discuss an experiment performed to test an array signal processing technique which searches for unperceivable sound in loud noise environments. Two speakers simultaneously played a noise of a generator and a voice decreased by 20 dB (= 1/100 of power) from the generator noise at an outdoor space where cicadas were making noise. The sound signal was received by a horizontally set linear microphone array 1.05 m in length and consisting of 15 microphones. The direction and the distance of the voice were computed and the sound of the voice was extracted and played back as an audible sound by array signal processing.

  8. Robust Sound Localization: An Application of an Auditory Perception System for a Humanoid Robot

    National Research Council Canada - National Science Library

    Irie, Robert E

    1995-01-01

    .... This thesis presents an integrated auditory system for a humanoid robot, currently under development, that will, among other things, learn to localize normal, everyday sounds in a realistic environment...

  9. Improvement of directionality and sound-localization by internal ear coupling in barn owls

    DEFF Research Database (Denmark)

    Wagner, Hermann; Christensen-Dalsgaard, Jakob; Kettler, Lutz

    Mark Konishi was one of the first to quantify sound-localization capabilities in barn owls. He showed that frequencies between 3 and 10 kHz underlie precise sound localization in these birds, and that they derive spatial information from processing interaural time and interaural level differences....... However, despite intensive research during the last 40 years it is still unclear whether and how internal ear coupling contributes to sound localization in the barn owl. Here we investigated ear directionality in anesthetized birds with the help of laser vibrometry. Care was taken that anesthesia...... time difference in the low-frequency range, barn owls hesitate to approach prey or turn their heads when only low-frequency auditory information is present in a stimulus they receive. Thus, the barn-owl's sound localization system seems to be adapted to work best in frequency ranges where interaural...

  10. Robust Sound Localization: An Application of an Auditory Perception System for a Humanoid Robot

    National Research Council Canada - National Science Library

    Irie, Robert E

    1995-01-01

    Localizing sounds with different frequency and time domain characteristics in a dynamic listening environment is a challenging task that has not been explored in the field of robotics as much as other perceptual tasks...

  11. The effect of brain lesions on sound localization in complex acoustic environments.

    Science.gov (United States)

    Zündorf, Ida C; Karnath, Hans-Otto; Lewald, Jörg

    2014-05-01

    Localizing sound sources of interest in cluttered acoustic environments--as in the 'cocktail-party' situation--is one of the most demanding challenges to the human auditory system in everyday life. In this study, stroke patients' ability to localize acoustic targets in a single-source and in a multi-source setup in the free sound field were directly compared. Subsequent voxel-based lesion-behaviour mapping analyses were computed to uncover the brain areas associated with a deficit in localization in the presence of multiple distracter sound sources rather than localization of individually presented sound sources. Analyses revealed a fundamental role of the right planum temporale in this task. The results from the left hemisphere were less straightforward, but suggested an involvement of inferior frontal and pre- and postcentral areas. These areas appear to be particularly involved in the spectrotemporal analyses crucial for effective segregation of multiple sound streams from various locations, beyond the currently known network for localization of isolated sound sources in otherwise silent surroundings.

  12. Looking at the ventriloquist: visual outcome of eye movements calibrates sound localization.

    Directory of Open Access Journals (Sweden)

    Daniel S Pages

    Full Text Available A general problem in learning is how the brain determines what lesson to learn (and what lessons not to learn. For example, sound localization is a behavior that is partially learned with the aid of vision. This process requires correctly matching a visual location to that of a sound. This is an intrinsically circular problem when sound location is itself uncertain and the visual scene is rife with possible visual matches. Here, we develop a simple paradigm using visual guidance of sound localization to gain insight into how the brain confronts this type of circularity. We tested two competing hypotheses. 1: The brain guides sound location learning based on the synchrony or simultaneity of auditory-visual stimuli, potentially involving a Hebbian associative mechanism. 2: The brain uses a 'guess and check' heuristic in which visual feedback that is obtained after an eye movement to a sound alters future performance, perhaps by recruiting the brain's reward-related circuitry. We assessed the effects of exposure to visual stimuli spatially mismatched from sounds on performance of an interleaved auditory-only saccade task. We found that when humans and monkeys were provided the visual stimulus asynchronously with the sound but as feedback to an auditory-guided saccade, they shifted their subsequent auditory-only performance toward the direction of the visual cue by 1.3-1.7 degrees, or 22-28% of the original 6 degree visual-auditory mismatch. In contrast when the visual stimulus was presented synchronously with the sound but extinguished too quickly to provide this feedback, there was little change in subsequent auditory-only performance. Our results suggest that the outcome of our own actions is vital to localizing sounds correctly. Contrary to previous expectations, visual calibration of auditory space does not appear to require visual-auditory associations based on synchrony/simultaneity.

  13. Sound localization and speech identification in the frontal median plane with a hear-through headset

    DEFF Research Database (Denmark)

    Hoffmann, Pablo F.; Møller, Anders Kalsgaard; Christensen, Flemming

    2014-01-01

    signals can be superimposed via earphone reproduction. An important aspect of the hear-through headset is its transparency, i.e. how close to real life can the electronically amplied sounds be perceived. Here we report experiments conducted to evaluate the auditory transparency of a hear-through headset...... prototype by comparing human performance in natural, hear-through, and fully occluded conditions for two spatial tasks: frontal vertical-plane sound localization and speech-on-speech spatial release from masking. Results showed that localization performance was impaired by the hear-through headset relative...... to the natural condition though not as much as in the fully occluded condition. Localization was affected the least when the sound source was in front of the listeners. Different from the vertical localization performance, results from the speech task suggest that normal speech-on-speech spatial release from...

  14. Analysis, Design and Implementation of an Embedded Realtime Sound Source Localization System Based on Beamforming Theory

    Directory of Open Access Journals (Sweden)

    Arko Djajadi

    2009-12-01

    Full Text Available This project is intended to analyze, design and implement a realtime sound source localization system by using a mobile robot as the media. The implementated system uses 2 microphones as the sensors, Arduino Duemilanove microcontroller system with ATMega328p as the microprocessor, two permanent magnet DC motors as the actuators for the mobile robot and a servo motor as the actuator to rotate the webcam directing to the location of the sound source, and a laptop/PC as the simulation and display media. In order to achieve the objective of finding the position of a specific sound source, beamforming theory is applied to the system. Once the location of the sound source is detected and determined, the choice is either the mobile robot will adjust its position according to the direction of the sound source or only webcam will rotate in the direction of the incoming sound simulating the use of this system in a video conference. The integrated system has been tested and the results show the system could localize in realtime a sound source placed randomly on a half circle area (0 - 1800 with a radius of 0.3m - 3m, assuming the system is the center point of the circle. Due to low ADC and processor speed, achievable best angular resolution is still limited to 25o.

  15. An Algorithm for the Accurate Localization of Sounds

    National Research Council Canada - National Science Library

    MacDonald, Justin A

    2005-01-01

    .... The algorithm requires no a priori knowledge of the stimuli to be localized. The accuracy of the algorithm was tested using binaural recordings from a pair of microphones mounted in the ear canals of an acoustic mannequin...

  16. Maximum likelihood approach to “informed” Sound Source Localization for Hearing Aid applications

    DEFF Research Database (Denmark)

    Farmani, Mojtaba; Pedersen, Michael Syskind; Tan, Zheng-Hua

    2015-01-01

    Most state-of-the-art Sound Source Localization (SSL) algorithms have been proposed for applications which are "uninformed'' about the target sound content; however, utilizing a wireless microphone worn by a target talker, enables recent Hearing Aid Systems (HASs) to access to an almost noise......-free sound signal of the target talker at the HAS via the wireless connection. Therefore, in this paper, we propose a maximum likelihood (ML) approach, which we call MLSSL, to estimate the Direction of Arrival (DoA) of the target signal given access to the target signal content. Compared with other "informed...

  17. Prior Visual Experience Modulates Learning of Sound Localization Among Blind Individuals.

    Science.gov (United States)

    Tao, Qian; Chan, Chetwyn C H; Luo, Yue-Jia; Li, Jian-Jun; Ting, Kin-Hung; Lu, Zhong-Lin; Whitfield-Gabrieli, Susan; Wang, Jun; Lee, Tatia M C

    2017-05-01

    Cross-modal learning requires the use of information from different sensory modalities. This study investigated how the prior visual experience of late blind individuals could modulate neural processes associated with learning of sound localization. Learning was realized by standardized training on sound localization processing, and experience was investigated by comparing brain activations elicited from a sound localization task in individuals with (late blind, LB) and without (early blind, EB) prior visual experience. After the training, EB showed decreased activation in the precuneus, which was functionally connected to a limbic-multisensory network. In contrast, LB showed the increased activation of the precuneus. A subgroup of LB participants who demonstrated higher visuospatial working memory capabilities (LB-HVM) exhibited an enhanced precuneus-lingual gyrus network. This differential connectivity suggests that visuospatial working memory due to the prior visual experience gained via LB-HVM enhanced learning of sound localization. Active visuospatial navigation processes could have occurred in LB-HVM compared to the retrieval of previously bound information from long-term memory for EB. The precuneus appears to play a crucial role in learning of sound localization, disregarding prior visual experience. Prior visual experience, however, could enhance cross-modal learning by extending binding to the integration of unprocessed information, mediated by the cognitive functions that these experiences develop.

  18. Sound localization in noise in hearing-impaired listeners.

    Science.gov (United States)

    Lorenzi, C; Gatehouse, S; Lever, C

    1999-06-01

    The present study assesses the ability of four listeners with high-frequency, bilateral symmetrical sensorineural hearing loss to localize and detect a broadband click train in the frontal-horizontal plane, in quiet and in the presence of a white noise. The speaker array and stimuli are identical to those described by Lorenzi et al. (in press). The results show that: (1) localization performance is only slightly poorer in hearing-impaired listeners than in normal-hearing listeners when noise is at 0 deg azimuth, (2) localization performance begins to decrease at higher signal-to-noise ratios for hearing-impaired listeners than for normal-hearing listeners when noise is at +/- 90 deg azimuth, and (3) the performance of hearing-impaired listeners is less consistent when noise is at +/- 90 deg azimuth than at 0 deg azimuth. The effects of a high-frequency hearing loss were also studied by measuring the ability of normal-hearing listeners to localize the low-pass filtered version of the clicks. The data reproduce the effects of noise on three out of the four hearing-impaired listeners when noise is at 0 deg azimuth. They reproduce the effects of noise on only two out of the four hearing-impaired listeners when noise is at +/- 90 deg azimuth. The additional effects of a low-frequency hearing loss were investigated by attenuating the low-pass filtered clicks and the noise by 20 dB. The results show that attenuation does not strongly affect localization accuracy for normal-hearing listeners. Measurements of the clicks' detectability indicate that the hearing-impaired listeners who show the poorest localization accuracy also show the poorest ability to detect the clicks. The inaudibility of high frequencies, "distortions," and reduced detectability of the signal are assumed to have caused the poorer-than-normal localization accuracy for hearing-impaired listeners.

  19. Sound localization with head movement: implications for 3-d audio displays.

    Directory of Open Access Journals (Sweden)

    Ken Ian McAnally

    2014-08-01

    Full Text Available Previous studies have shown that the accuracy of sound localization is improved if listeners are allowed to move their heads during signal presentation. This study describes the function relating localization accuracy to the extent of head movement in azimuth. Sounds that are difficult to localize were presented in the free field from sources at a wide range of azimuths and elevations. Sounds remained active until the participants’ heads had rotated through windows ranging in width of 2°, 4°, 8°, 16°, 32°, or 64° of azimuth. Error in determining sound-source elevation and the rate of front/back confusion were found to decrease with increases in azimuth window width. Error in determining sound-source lateral angle was not found to vary with azimuth window width. Implications for 3-d audio displays: The utility of a 3-d audio display for imparting spatial information is likely to be improved if operators are able to move their heads during signal presentation. Head movement may compensate in part for a paucity of spectral cues to sound-source location resulting from limitations in either the audio signals presented or the directional filters (i.e., head-related transfer functions used to generate a display. However, head movements of a moderate size (i.e., through around 32° of azimuth may be required to ensure that spatial information is conveyed with high accuracy.

  20. Sound Localization in Patients With Congenital Unilateral Conductive Hearing Loss With a Transcutaneous Bone Conduction Implant.

    Science.gov (United States)

    Vyskocil, Erich; Liepins, Rudolfs; Kaider, Alexandra; Blineder, Michaela; Hamzavi, Sasan

    2017-03-01

    There is no consensus regarding the benefit of implantable hearing aids in congenital unilateral conductive hearing loss (UCHL). This study aimed to measure sound source localization performance in patients with congenital UCHL and contralateral normal hearing who received a new bone conduction implant. Evaluation of within-subject performance differences for sound source localization in a horizontal plane. Tertiary referral center. Five patients with atresia of the external auditory canal and contralateral normal hearing implanted with transcutaneous bone conduction implant at the Medical University of Vienna were tested. Activated/deactivated implant. Sound source localization test; localization performance quantified using the root mean square (RMS) error. Sound source localization ability was highly variable among individual subjects, with RMS errors ranging from 21 to 40 degrees. Horizontal plane localization performance in aided conditions showed statistically significant improvement compared with the unaided conditions, with RMS errors ranging from 17 to 27 degrees. The mean RMS error decreased by a factor of 0.71 (p conduction implant. Some patients with congenital UCHL might be capable of developing improved horizontal plane localization abilities with the binaural cues provided by this device.

  1. Hybrid local piezoelectric and conductive functions for high performance airborne sound absorption

    Science.gov (United States)

    Rahimabady, Mojtaba; Statharas, Eleftherios Christos; Yao, Kui; Sharifzadeh Mirshekarloo, Meysam; Chen, Shuting; Tay, Francis Eng Hock

    2017-12-01

    A concept of hybrid local piezoelectric and electrical conductive functions for improving airborne sound absorption is proposed and demonstrated in composite foam made of porous polar polyvinylidene fluoride (PVDF) mixed with conductive single-walled carbon nanotube (SWCNT). According to our hybrid material function design, the local piezoelectric effect in the PVDF matrix with the polar structure and the electrical resistive loss of SWCNT enhanced sound energy conversion to electrical energy and subsequently to thermal energy, respectively, in addition to the other known sound absorption mechanisms in a porous material. It is found that the overall energy conversion and hence the sound absorption performance are maximized when the concentration of the SWCNT is around the conductivity percolation threshold. For the optimal composition of PVDF/5 wt. % SWCNT, a sound reduction coefficient of larger than 0.58 has been obtained, with a high sound absorption coefficient higher than 50% at 600 Hz, showing their great values for passive noise mitigation even at a low frequency.

  2. Physiological correlates of sound localization in a parasitoid fly, Ormia ochracea

    Science.gov (United States)

    Oshinsky, Michael Lee

    A major focus of research in the nervous system is the investigation of neural circuits. The question of how neurons connect to form functional units has driven modern neuroscience research from its inception. From the beginning, the neural circuits of the auditory system and specifically sound localization were used as a model system for investigating neural connectivity and computation. Sound localization lends itself to this task because there is no mapping of spatial information on a receptor sheet as in vision. With only one eye, an animal would still have positional information for objects. Since the receptor sheet in the ear is frequency oriented and not spatially oriented, positional information for a sound source does not exist with only one ear. The nervous system computes the location of a sound source based on differences in the physiology of the two ears. In this study, I investigated the neural circuits for sound localization in a fly, Ormia ochracea (Diptera, Tachinidae, Ormiini), which is a parasitoid of crickets. This fly possess a unique mechanically coupled hearing organ. The two ears are contained in one air sac and a cuticular bridge, that has a flexible spring-like structure at its center, connects them. This mechanical coupling preprocesses the sound before it is detected by the nervous system and provides the fly with directional information. The subject of this study is the neural coding of the location of sound stimuli by a mechanically coupled auditory system. In chapter 1, I present the natural history of an acoustic parasitoid and I review the peripheral processing of sound by the Ormian ear. In chapter 2, I describe the anatomy and physiology of the auditory afferents. I present this physiology in the context of sound localization. In chapter 3, I describe the directional dependent physiology for the thoracic local and ascending acoustic interneurons. In chapter 4, I quantify the threshold and I detail the kinematics of the phonotactic

  3. Audio-Visual Fusion for Sound Source Localization and Improved Attention

    International Nuclear Information System (INIS)

    Lee, Byoung Gi; Choi, Jong Suk; Yoon, Sang Suk; Choi, Mun Taek; Kim, Mun Sang; Kim, Dai Jin

    2011-01-01

    Service robots are equipped with various sensors such as vision camera, sonar sensor, laser scanner, and microphones. Although these sensors have their own functions, some of them can be made to work together and perform more complicated functions. AudioFvisual fusion is a typical and powerful combination of audio and video sensors, because audio information is complementary to visual information and vice versa. Human beings also mainly depend on visual and auditory information in their daily life. In this paper, we conduct two studies using audioFvision fusion: one is on enhancing the performance of sound localization, and the other is on improving robot attention through sound localization and face detection

  4. Localization of self-generated synthetic footstep sounds on different walked-upon materials through headphones

    DEFF Research Database (Denmark)

    Turchet, Luca; Spagnol, Simone; Geronazzo, Michele

    2016-01-01

    typologies of surface materials: solid (e.g., wood) and aggregate (e.g., gravel). Different sound delivery methods (mono, stereo, binaural) as well as several surface materials, in presence or absence of concurrent contextual auditory information provided as soundscapes, were evaluated in a vertical...... localization task. Results showed that solid surfaces were localized significantly farther from the walker's feet than the aggregate ones. This effect was independent of the used rendering technique, of the presence of soundscapes, and of merely temporal or spectral attributes of sound. The effect...

  5. Audio-Visual Fusion for Sound Source Localization and Improved Attention

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byoung Gi; Choi, Jong Suk; Yoon, Sang Suk; Choi, Mun Taek; Kim, Mun Sang [Korea Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Dai Jin [Pohang University of Science and Technology, Pohang (Korea, Republic of)

    2011-07-15

    Service robots are equipped with various sensors such as vision camera, sonar sensor, laser scanner, and microphones. Although these sensors have their own functions, some of them can be made to work together and perform more complicated functions. AudioFvisual fusion is a typical and powerful combination of audio and video sensors, because audio information is complementary to visual information and vice versa. Human beings also mainly depend on visual and auditory information in their daily life. In this paper, we conduct two studies using audioFvision fusion: one is on enhancing the performance of sound localization, and the other is on improving robot attention through sound localization and face detection.

  6. Evolution of Sound Source Localization Circuits in the Nonmammalian Vertebrate Brainstem

    DEFF Research Database (Denmark)

    Walton, Peggy L; Christensen-Dalsgaard, Jakob; Carr, Catherine E

    2017-01-01

    The earliest vertebrate ears likely subserved a gravistatic function for orientation in the aquatic environment. However, in addition to detecting acceleration created by the animal's own movements, the otolithic end organs that detect linear acceleration would have responded to particle movement...... to increased sensitivity to a broader frequency range and to modification of the preexisting circuitry for sound source localization....

  7. 3-D inversion of airborne electromagnetic data parallelized and accelerated by local mesh and adaptive soundings

    Science.gov (United States)

    Yang, Dikun; Oldenburg, Douglas W.; Haber, Eldad

    2014-03-01

    Airborne electromagnetic (AEM) methods are highly efficient tools for assessing the Earth's conductivity structures in a large area at low cost. However, the configuration of AEM measurements, which typically have widely distributed transmitter-receiver pairs, makes the rigorous modelling and interpretation extremely time-consuming in 3-D. Excessive overcomputing can occur when working on a large mesh covering the entire survey area and inverting all soundings in the data set. We propose two improvements. The first is to use a locally optimized mesh for each AEM sounding for the forward modelling and calculation of sensitivity. This dedicated local mesh is small with fine cells near the sounding location and coarse cells far away in accordance with EM diffusion and the geometric decay of the signals. Once the forward problem is solved on the local meshes, the sensitivity for the inversion on the global mesh is available through quick interpolation. Using local meshes for AEM forward modelling avoids unnecessary computing on fine cells on a global mesh that are far away from the sounding location. Since local meshes are highly independent, the forward modelling can be efficiently parallelized over an array of processors. The second improvement is random and dynamic down-sampling of the soundings. Each inversion iteration only uses a random subset of the soundings, and the subset is reselected for every iteration. The number of soundings in the random subset, determined by an adaptive algorithm, is tied to the degree of model regularization. This minimizes the overcomputing caused by working with redundant soundings. Our methods are compared against conventional methods and tested with a synthetic example. We also invert a field data set that was previously considered to be too large to be practically inverted in 3-D. These examples show that our methodology can dramatically reduce the processing time of 3-D inversion to a practical level without losing resolution

  8. Development of Sound Localization Strategies in Children with Bilateral Cochlear Implants.

    Directory of Open Access Journals (Sweden)

    Yi Zheng

    Full Text Available Localizing sounds in our environment is one of the fundamental perceptual abilities that enable humans to communicate, and to remain safe. Because the acoustic cues necessary for computing source locations consist of differences between the two ears in signal intensity and arrival time, sound localization is fairly poor when a single ear is available. In adults who become deaf and are fitted with cochlear implants (CIs sound localization is known to improve when bilateral CIs (BiCIs are used compared to when a single CI is used. The aim of the present study was to investigate the emergence of spatial hearing sensitivity in children who use BiCIs, with a particular focus on the development of behavioral localization patterns when stimuli are presented in free-field horizontal acoustic space. A new analysis was implemented to quantify patterns observed in children for mapping acoustic space to a spatially relevant perceptual representation. Children with normal hearing were found to distribute their responses in a manner that demonstrated high spatial sensitivity. In contrast, children with BiCIs tended to classify sound source locations to the left and right; with increased bilateral hearing experience, they developed a perceptual map of space that was better aligned with the acoustic space. The results indicate experience-dependent refinement of spatial hearing skills in children with CIs. Localization strategies appear to undergo transitions from sound source categorization strategies to more fine-grained location identification strategies. This may provide evidence for neural plasticity, with implications for training of spatial hearing ability in CI users.

  9. Crowing Sound Analysis of Gaga' Chicken; Local Chicken from South Sulawesi Indonesia

    OpenAIRE

    Aprilita Bugiwati, Sri Rachma; Ashari, Fachri

    2008-01-01

    Gaga??? chicken was known as a local chicken at South Sulawesi Indonesia which has unique, specific, and different crowing sound, especially at the ending of crowing sound which is like the voice character of human laughing, comparing with the other types of singing chicken in the world. 287 birds of Gaga??? chicken at 3 districts at the centre habitat of Gaga??? chicken were separated into 2 groups (163 birds of Dangdut type and 124 birds of Slow type) which is based on the speed...

  10. Repeatability of visual acuity measurement.

    Science.gov (United States)

    Raasch, T W; Bailey, I L; Bullimore, M A

    1998-05-01

    This study investigates features of visual acuity chart design and acuity testing scoring methods which affect the validity and repeatability of visual acuity measurements. Visual acuity was measured using the Sloan and British Standard letter series, and Landolt rings. Identifiability of the different letters as a function of size was estimated, and expressed in the form of frequency-of-seeing curves. These functions were then used to simulate acuity measurements with a variety of chart designs and scoring criteria. Systematic relationships exist between chart design parameters and acuity score, and acuity score repeatability. In particular, an important feature of a chart, that largely determines the repeatability of visual acuity measurement, is the amount of size change attributed to each letter. The methods used to score visual acuity performance also affect repeatability. It is possible to evaluate acuity score validity and repeatability using the statistical principles discussed here.

  11. A novel method for direct localized sound speed measurement using the virtual source paradigm

    DEFF Research Database (Denmark)

    Byram, Brett; Trahey, Gregg E.; Jensen, Jørgen Arendt

    2007-01-01

    ) mediums. The inhomogeneous mediums were arranged as an oil layer, one 6 mm thick and the other 11 mm thick, on top of a water layer. To complement the phantom studies, sources of error for spatial registration of virtual detectors were simulated. The sources of error presented here are multiple sound...... registered virtual detector. Between a pair of registered virtual detectors a spherical wave is propagated. By beamforming the received data the time of flight between the two virtual sources can be calculated. From this information the local sound speed can be estimated. Validation of the estimator used...... both phantom and simulation results. The phantom consisted of two wire targets located near the transducer's axis at depths of 17 and 28 mm. Using this phantom the sound speed between the wires was measured for a homogeneous (water) medium and for two inhomogeneous (DB-grade castor oil and water...

  12. An acuity cards cookbook.

    Science.gov (United States)

    Vital-Durand, F

    1996-01-01

    Acuity cards are being more commonly used in clinical and screening practice. The author describes his experience from over 6000 infants tested with the method, using two commercially available sets of cards to provide users with comprehensive guidelines to allow them to get the most out of this useful test.

  13. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    Directory of Open Access Journals (Sweden)

    Shimoda T

    2017-03-01

    sound recordings could be used to identify sites of local airway inflammation. Keywords: airway obstruction, expiration sound pressure level, inspiration sound pressure level, expiration-to-inspiration sound pressure ratio, 7-point analysis

  14. Design of UAV-Embedded Microphone Array System for Sound Source Localization in Outdoor Environments

    Directory of Open Access Journals (Sweden)

    Kotaro Hoshiba

    2017-11-01

    Full Text Available In search and rescue activities, unmanned aerial vehicles (UAV should exploit sound information to compensate for poor visual information. This paper describes the design and implementation of a UAV-embedded microphone array system for sound source localization in outdoor environments. Four critical development problems included water-resistance of the microphone array, efficiency in assembling, reliability of wireless communication, and sufficiency of visualization tools for operators. To solve these problems, we developed a spherical microphone array system (SMAS consisting of a microphone array, a stable wireless network communication system, and intuitive visualization tools. The performance of SMAS was evaluated with simulated data and a demonstration in the field. Results confirmed that the SMAS provides highly accurate localization, water resistance, prompt assembly, stable wireless communication, and intuitive information for observers and operators.

  15. Design of UAV-Embedded Microphone Array System for Sound Source Localization in Outdoor Environments †

    Science.gov (United States)

    Hoshiba, Kotaro; Washizaki, Kai; Wakabayashi, Mizuho; Ishiki, Takahiro; Bando, Yoshiaki; Gabriel, Daniel; Nakadai, Kazuhiro; Okuno, Hiroshi G.

    2017-01-01

    In search and rescue activities, unmanned aerial vehicles (UAV) should exploit sound information to compensate for poor visual information. This paper describes the design and implementation of a UAV-embedded microphone array system for sound source localization in outdoor environments. Four critical development problems included water-resistance of the microphone array, efficiency in assembling, reliability of wireless communication, and sufficiency of visualization tools for operators. To solve these problems, we developed a spherical microphone array system (SMAS) consisting of a microphone array, a stable wireless network communication system, and intuitive visualization tools. The performance of SMAS was evaluated with simulated data and a demonstration in the field. Results confirmed that the SMAS provides highly accurate localization, water resistance, prompt assembly, stable wireless communication, and intuitive information for observers and operators. PMID:29099790

  16. Design of UAV-Embedded Microphone Array System for Sound Source Localization in Outdoor Environments.

    Science.gov (United States)

    Hoshiba, Kotaro; Washizaki, Kai; Wakabayashi, Mizuho; Ishiki, Takahiro; Kumon, Makoto; Bando, Yoshiaki; Gabriel, Daniel; Nakadai, Kazuhiro; Okuno, Hiroshi G

    2017-11-03

    In search and rescue activities, unmanned aerial vehicles (UAV) should exploit sound information to compensate for poor visual information. This paper describes the design and implementation of a UAV-embedded microphone array system for sound source localization in outdoor environments. Four critical development problems included water-resistance of the microphone array, efficiency in assembling, reliability of wireless communication, and sufficiency of visualization tools for operators. To solve these problems, we developed a spherical microphone array system (SMAS) consisting of a microphone array, a stable wireless network communication system, and intuitive visualization tools. The performance of SMAS was evaluated with simulated data and a demonstration in the field. Results confirmed that the SMAS provides highly accurate localization, water resistance, prompt assembly, stable wireless communication, and intuitive information for observers and operators.

  17. Do you hear where I hear?: Isolating the individualized sound localization cues.

    Directory of Open Access Journals (Sweden)

    Griffin David Romigh

    2014-12-01

    Full Text Available It is widely acknowledged that individualized head-related transfer function (HRTF measurements are needed to adequately capture all of the 3D spatial hearing cues. However, many perceptual studies have shown that localization accuracy in the lateral dimension is only minimally decreased by the use of non-individualized head-related transfer functions. This evidence supports the idea that the individualized components of an HRTF could be isolated from those that are more general in nature. In the present study we decomposed the HRTF at each location into average, lateral and intraconic spectral components, along with an ITD in an effort to isolate the sound localization cues that are responsible for the inter-individual differences in localization performance. HRTFs for a given listener were then reconstructed systematically with components that were both individualized and non-individualized in nature, and the effect of each modification was analyzed via a virtual localization test where brief 250-ms noise bursts were rendered with the modified HRTFs. Results indicate that the cues important for individualization of HRTFs are contained almost exclusively in the intraconic portion of the HRTF spectra and localization is only minimally affected by introducing non-individualized cues into the other HRTF components. These results provide new insights into what specific inter-individual differences in head-related acoustical features are most relevant to sound localization, and provide a framework for how future human-machine interfaces might be more effectively generalized and/or individualized.

  18. Localization of Simultaneous Moving Sound Sources for Mobile Robot Using a Frequency-Domain Steered Beamformer Approach

    OpenAIRE

    Valin, Jean-Marc; Michaud, François; Hadjou, Brahim; Rouat, Jean

    2016-01-01

    Mobile robots in real-life settings would benefit from being able to localize sound sources. Such a capability can nicely complement vision to help localize a person or an interesting event in the environment, and also to provide enhanced processing for other capabilities such as speech recognition. In this paper we present a robust sound source localization method in three-dimensional space using an array of 8 microphones. The method is based on a frequency-domain implementation of a steered...

  19. The natural history of sound localization in mammals – a story of neuronal inhibition

    Directory of Open Access Journals (Sweden)

    Benedikt eGrothe

    2014-10-01

    Full Text Available Our concepts of sound localization in the vertebrate brain are widely based on the general assumption that both the ability to detect air-borne sounds and the neuronal processing are homologous in archosaurs (present day crocodiles and birds and mammals. Yet studies repeatedly report conflicting results on the neuronal circuits and mechanisms, in particular the role of inhibition, as well as the coding strategies between avian and mammalian model systems.Here we argue that mammalian and avian phylogeny of spatial hearing is characterized by a convergent evolution of hearing air-borne sounds rather than by homology. In particular, the different evolutionary origins of tympanic ears and the different availability of binaural cues in early mammals and archosaurs imposed distinct constraints on the respective binaural processing mechanisms. The role of synaptic inhibition in generating binaural spatial sensitivity in mammals is highlighted, as it reveals a unifying principle of mammalian circuit design for encoding sound position. Together, we combine evolutionary, anatomical and physiological arguments for making a clear distinction between mammalian processing mechanisms and coding strategies and those of archosaurs. We emphasize that a consideration of the convergent nature of neuronal mechanisms will significantly increase the explanatory power of studies of spatial processing in both mammals and birds.

  20. The natural history of sound localization in mammals--a story of neuronal inhibition.

    Science.gov (United States)

    Grothe, Benedikt; Pecka, Michael

    2014-01-01

    Our concepts of sound localization in the vertebrate brain are widely based on the general assumption that both the ability to detect air-borne sounds and the neuronal processing are homologous in archosaurs (present day crocodiles and birds) and mammals. Yet studies repeatedly report conflicting results on the neuronal circuits and mechanisms, in particular the role of inhibition, as well as the coding strategies between avian and mammalian model systems. Here we argue that mammalian and avian phylogeny of spatial hearing is characterized by a convergent evolution of hearing air-borne sounds rather than by homology. In particular, the different evolutionary origins of tympanic ears and the different availability of binaural cues in early mammals and archosaurs imposed distinct constraints on the respective binaural processing mechanisms. The role of synaptic inhibition in generating binaural spatial sensitivity in mammals is highlighted, as it reveals a unifying principle of mammalian circuit design for encoding sound position. Together, we combine evolutionary, anatomical and physiological arguments for making a clear distinction between mammalian processing mechanisms and coding strategies and those of archosaurs. We emphasize that a consideration of the convergent nature of neuronal mechanisms will significantly increase the explanatory power of studies of spatial processing in both mammals and birds.

  1. Near-Field Sound Localization Based on the Small Profile Monaural Structure

    Directory of Open Access Journals (Sweden)

    Youngwoong Kim

    2015-11-01

    Full Text Available The acoustic wave around a sound source in the near-field area presents unconventional properties in the temporal, spectral, and spatial domains due to the propagation mechanism. This paper investigates a near-field sound localizer in a small profile structure with a single microphone. The asymmetric structure around the microphone provides a distinctive spectral variation that can be recognized by the dedicated algorithm for directional localization. The physical structure consists of ten pipes of different lengths in a vertical fashion and rectangular wings positioned between the pipes in radial directions. The sound from an individual direction travels through the nearest open pipe, which generates the particular fundamental frequency according to the acoustic resonance. The Cepstral parameter is modified to evaluate the fundamental frequency. Once the system estimates the fundamental frequency of the received signal, the length of arrival and angle of arrival (AoA are derived by the designed model. From an azimuthal distance of 3–15 cm from the outer body of the pipes, the extensive acoustic experiments with a 3D-printed structure show that the direct and side directions deliver average hit rates of 89% and 73%, respectively. The closer positions to the system demonstrate higher accuracy, and the overall hit rate performance is 78% up to 15 cm away from the structure body.

  2. Sound localization and word discrimination in reverberant environment in children with developmental dyslexia

    Directory of Open Access Journals (Sweden)

    Wendy Castro-Camacho

    2015-04-01

    Full Text Available Objective Compare if localization of sounds and words discrimination in reverberant environment is different between children with dyslexia and controls. Method We studied 30 children with dyslexia and 30 controls. Sound and word localization and discrimination was studied in five angles from left to right auditory fields (-90o, -45o, 0o, +45o, +90o, under reverberant and no-reverberant conditions; correct answers were compared. Results Spatial location of words in no-reverberant test was deficient in children with dyslexia at 0º and +90o. Spatial location for reverberant test was altered in children with dyslexia at all angles, except –-90o. Word discrimination in no-reverberant test in children with dyslexia had a poor performance at left angles. In reverberant test, children with dyslexia exhibited deficiencies at -45o, -90o, and +45o angles. Conclusion Children with dyslexia could had problems when have to locate sound, and discriminate words in extreme locations of the horizontal plane in classrooms with reverberation.

  3. ICE on the road to auditory sensitivity reduction and sound localization in the frog.

    Science.gov (United States)

    Narins, Peter M

    2016-10-01

    Frogs and toads are capable of producing calls at potentially damaging levels that exceed 110 dB SPL at 50 cm. Most frog species have internally coupled ears (ICE) in which the tympanic membranes (TyMs) communicate directly via the large, permanently open Eustachian tubes, resulting in an inherently directional asymmetrical pressure-difference receiver. One active mechanism for auditory sensitivity reduction involves the pressure increase during vocalization that distends the TyM, reducing its low-frequency airborne sound sensitivity. Moreover, if sounds generated by the vocal folds arrive at both surfaces of the TyM with nearly equal amplitudes and phases, the net motion of the eardrum would be greatly attenuated. Both of these processes appear to reduce the motion of the frog's TyM during vocalizations. The implications of ICE in amphibians with respect to sound localizations are discussed, and the particularly interesting case of frogs that use ultrasound for communication yet exhibit exquisitely small localization jump errors is brought to light.

  4. Cue Reliability Represented in the Shape of Tuning Curves in the Owl's Sound Localization System.

    Science.gov (United States)

    Cazettes, Fanny; Fischer, Brian J; Peña, Jose L

    2016-02-17

    Optimal use of sensory information requires that the brain estimates the reliability of sensory cues, but the neural correlate of cue reliability relevant for behavior is not well defined. Here, we addressed this issue by examining how the reliability of spatial cue influences neuronal responses and behavior in the owl's auditory system. We show that the firing rate and spatial selectivity changed with cue reliability due to the mechanisms generating the tuning to the sound localization cue. We found that the correlated variability among neurons strongly depended on the shape of the tuning curves. Finally, we demonstrated that the change in the neurons' selectivity was necessary and sufficient for a network of stochastic neurons to predict behavior when sensory cues were corrupted with noise. This study demonstrates that the shape of tuning curves can stand alone as a coding dimension of environmental statistics. In natural environments, sensory cues are often corrupted by noise and are therefore unreliable. To make the best decisions, the brain must estimate the degree to which a cue can be trusted. The behaviorally relevant neural correlates of cue reliability are debated. In this study, we used the barn owl's sound localization system to address this question. We demonstrated that the mechanisms that account for spatial selectivity also explained how neural responses changed with degraded signals. This allowed for the neurons' selectivity to capture cue reliability, influencing the population readout commanding the owl's sound-orienting behavior. Copyright © 2016 the authors 0270-6474/16/362101-10$15.00/0.

  5. On the influence of microphone array geometry on HRTF-based Sound Source Localization

    DEFF Research Database (Denmark)

    Farmani, Mojtaba; Pedersen, Michael Syskind; Tan, Zheng-Hua

    2015-01-01

    The direction dependence of Head Related Transfer Functions (HRTFs) forms the basis for HRTF-based Sound Source Localization (SSL) algorithms. In this paper, we show how spectral similarities of the HRTFs of different directions in the horizontal plane influence performance of HRTF-based SSL...... algorithms; the more similar the HRTFs of different angles to the HRTF of the target angle, the worse the performance. However, we also show how the microphone array geometry can assist in differentiating between the HRTFs of the different angles, thereby improving performance of HRTF-based SSL algorithms....... Furthermore, to demonstrate the analysis results, we show the impact of HRTFs similarities and microphone array geometry on an exemplary HRTF-based SSL algorithm, called MLSSL. This algorithm is well-suited for this purpose as it allows to estimate the Direction-of-Arrival (DoA) of the target sound using any...

  6. Ormiaochracea as a Model Organism in Sound Localization Experiments and in Inventing Hearing Aids.

    Directory of Open Access Journals (Sweden)

    - -

    1998-09-01

    Full Text Available Hearing aid prescription for patients suffering hearing loss has always been one of the main concerns of the audiologists. Thanks to technology that has provided Hearing aids with digital and computerized systems which has improved the quality of sound heard by hearing aids. Though we can learn from nature in inventing such instruments as in the current article that has been channeled to a kind of fruit fly. Ormiaochracea is a small yellow nocturnal fly, a parasitoid of crickets. It is notable because of its exceptionally acute directional hearing. In the current article we will discuss how it has become a model organism in sound localization experiments and in inventing hearing aids.

  7. Mice Lacking the Alpha9 Subunit of the Nicotinic Acetylcholine Receptor Exhibit Deficits in Frequency Difference Limens and Sound Localization

    Directory of Open Access Journals (Sweden)

    Amanda Clause

    2017-06-01

    Full Text Available Sound processing in the cochlea is modulated by cholinergic efferent axons arising from medial olivocochlear neurons in the brainstem. These axons contact outer hair cells in the mature cochlea and inner hair cells during development and activate nicotinic acetylcholine receptors composed of α9 and α10 subunits. The α9 subunit is necessary for mediating the effects of acetylcholine on hair cells as genetic deletion of the α9 subunit results in functional cholinergic de-efferentation of the cochlea. Cholinergic modulation of spontaneous cochlear activity before hearing onset is important for the maturation of central auditory circuits. In α9KO mice, the developmental refinement of inhibitory afferents to the lateral superior olive is disturbed, resulting in decreased tonotopic organization of this sound localization nucleus. In this study, we used behavioral tests to investigate whether the circuit anomalies in α9KO mice correlate with sound localization or sound frequency processing. Using a conditioned lick suppression task to measure sound localization, we found that three out of four α9KO mice showed impaired minimum audible angles. Using a prepulse inhibition of the acoustic startle response paradigm, we found that the ability of α9KO mice to detect sound frequency changes was impaired, whereas their ability to detect sound intensity changes was not. These results demonstrate that cholinergic, nicotinic α9 subunit mediated transmission in the developing cochlear plays an important role in the maturation of hearing.

  8. Tactile acuity charts: a reliable measure of spatial acuity.

    Directory of Open Access Journals (Sweden)

    Patrick Bruns

    Full Text Available For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  9. Tactile acuity charts: a reliable measure of spatial acuity.

    Science.gov (United States)

    Bruns, Patrick; Camargo, Carlos J; Campanella, Humberto; Esteve, Jaume; Dinse, Hubert R; Röder, Brigitte

    2014-01-01

    For assessing tactile spatial resolution it has recently been recommended to use tactile acuity charts which follow the design principles of the Snellen letter charts for visual acuity and involve active touch. However, it is currently unknown whether acuity thresholds obtained with this newly developed psychophysical procedure are in accordance with established measures of tactile acuity that involve passive contact with fixed duration and control of contact force. Here we directly compared tactile acuity thresholds obtained with the acuity charts to traditional two-point and grating orientation thresholds in a group of young healthy adults. For this purpose, two types of charts, using either Braille-like dot patterns or embossed Landolt rings with different orientations, were adapted from previous studies. Measurements with the two types of charts were equivalent, but generally more reliable with the dot pattern chart. A comparison with the two-point and grating orientation task data showed that the test-retest reliability of the acuity chart measurements after one week was superior to that of the passive methods. Individual thresholds obtained with the acuity charts agreed reasonably with the grating orientation threshold, but less so with the two-point threshold that yielded relatively distinct acuity estimates compared to the other methods. This potentially considerable amount of mismatch between different measures of tactile acuity suggests that tactile spatial resolution is a complex entity that should ideally be measured with different methods in parallel. The simple test procedure and high reliability of the acuity charts makes them a promising complement and alternative to the traditional two-point and grating orientation thresholds.

  10. Sound Source Localization through 8 MEMS Microphones Array Using a Sand-Scorpion-Inspired Spiking Neural Network.

    Science.gov (United States)

    Beck, Christoph; Garreau, Guillaume; Georgiou, Julius

    2016-01-01

    Sand-scorpions and many other arachnids perceive their environment by using their feet to sense ground waves. They are able to determine amplitudes the size of an atom and locate the acoustic stimuli with an accuracy of within 13° based on their neuronal anatomy. We present here a prototype sound source localization system, inspired from this impressive performance. The system presented utilizes custom-built hardware with eight MEMS microphones, one for each foot, to acquire the acoustic scene, and a spiking neural model to localize the sound source. The current implementation shows smaller localization error than those observed in nature.

  11. Sound Source Localization Through 8 MEMS Microphones Array Using a Sand-Scorpion-Inspired Spiking Neural Network

    Directory of Open Access Journals (Sweden)

    Christoph Beck

    2016-10-01

    Full Text Available Sand-scorpions and many other arachnids perceive their environment by using their feet to sense ground waves. They are able to determine amplitudes the size of an atom and locate the acoustic stimuli with an accuracy of within 13° based on their neuronal anatomy. We present here a prototype sound source localization system, inspired from this impressive performance. The system presented utilizes custom-built hardware with eight MEMS microphones, one for each foot, to acquire the acoustic scene, and a spiking neural model to localize the sound source. The current implementation shows smaller localization error than those observed in nature.

  12. Towards a Synesthesia Laboratory: Real-time Localization and Visualization of a Sound Source for Virtual Reality Applications

    OpenAIRE

    Kose, Ahmet; Tepljakov, Aleksei; Astapov, Sergei; Draheim, Dirk; Petlenkov, Eduard; Vassiljeva, Kristina

    2018-01-01

    In this paper, we present our findings related to the problem of localization and visualization of a sound source placed in the same room as the listener. The particular effect that we aim to investigate is called synesthesia—the act of experiencing one sense modality as another, e.g., a person may vividly experience flashes of colors when listening to a series of sounds. Towards that end, we apply a series of recently developed methods for detecting sound source in a three-dimensional space ...

  13. The role of envelope shape in the localization of multiple sound sources and echoes in the barn owl.

    Science.gov (United States)

    Baxter, Caitlin S; Nelson, Brian S; Takahashi, Terry T

    2013-02-01

    Echoes and sounds of independent origin often obscure sounds of interest, but echoes can go undetected under natural listening conditions, a perception called the precedence effect. How does the auditory system distinguish between echoes and independent sources? To investigate, we presented two broadband noises to barn owls (Tyto alba) while varying the similarity of the sounds' envelopes. The carriers of the noises were identical except for a 2- or 3-ms delay. Their onsets and offsets were also synchronized. In owls, sound localization is guided by neural activity on a topographic map of auditory space. When there are two sources concomitantly emitting sounds with overlapping amplitude spectra, space map neurons discharge when the stimulus in their receptive field is louder than the one outside it and when the averaged amplitudes of both sounds are rising. A model incorporating these features calculated the strengths of the two sources' representations on the map (B. S. Nelson and T. T. Takahashi; Neuron 67: 643-655, 2010). The target localized by the owls could be predicted from the model's output. The model also explained why the echo is not localized at short delays: when envelopes are similar, peaks in the leading sound mask corresponding peaks in the echo, weakening the echo's space map representation. When the envelopes are dissimilar, there are few or no corresponding peaks, and the owl localizes whichever source is predicted by the model to be less masked. Thus the precedence effect in the owl is a by-product of a mechanism for representing multiple sound sources on its map.

  14. A Survey of Sound Source Localization Methods in Wireless Acoustic Sensor Networks

    Directory of Open Access Journals (Sweden)

    Maximo Cobos

    2017-01-01

    Full Text Available Wireless acoustic sensor networks (WASNs are formed by a distributed group of acoustic-sensing devices featuring audio playing and recording capabilities. Current mobile computing platforms offer great possibilities for the design of audio-related applications involving acoustic-sensing nodes. In this context, acoustic source localization is one of the application domains that have attracted the most attention of the research community along the last decades. In general terms, the localization of acoustic sources can be achieved by studying energy and temporal and/or directional features from the incoming sound at different microphones and using a suitable model that relates those features with the spatial location of the source (or sources of interest. This paper reviews common approaches for source localization in WASNs that are focused on different types of acoustic features, namely, the energy of the incoming signals, their time of arrival (TOA or time difference of arrival (TDOA, the direction of arrival (DOA, and the steered response power (SRP resulting from combining multiple microphone signals. Additionally, we discuss methods not only aimed at localizing acoustic sources but also designed to locate the nodes themselves in the network. Finally, we discuss current challenges and frontiers in this field.

  15. A functional neuroimaging study of sound localization: visual cortex activity predicts performance in early-blind individuals.

    Directory of Open Access Journals (Sweden)

    Frédéric Gougoux

    2005-02-01

    Full Text Available Blind individuals often demonstrate enhanced nonvisual perceptual abilities. However, the neural substrate that underlies this improved performance remains to be fully understood. An earlier behavioral study demonstrated that some early-blind people localize sounds more accurately than sighted controls using monaural cues. In order to investigate the neural basis of these behavioral differences in humans, we carried out functional imaging studies using positron emission tomography and a speaker array that permitted pseudo-free-field presentations within the scanner. During binaural sound localization, a sighted control group showed decreased cerebral blood flow in the occipital lobe, which was not seen in early-blind individuals. During monaural sound localization (one ear plugged, the subgroup of early-blind subjects who were behaviorally superior at sound localization displayed two activation foci in the occipital cortex. This effect was not seen in blind persons who did not have superior monaural sound localization abilities, nor in sighted individuals. The degree of activation of one of these foci was strongly correlated with sound localization accuracy across the entire group of blind subjects. The results show that those blind persons who perform better than sighted persons recruit occipital areas to carry out auditory localization under monaural conditions. We therefore conclude that computations carried out in the occipital cortex specifically underlie the enhanced capacity to use monaural cues. Our findings shed light not only on intermodal compensatory mechanisms, but also on individual differences in these mechanisms and on inhibitory patterns that differ between sighted individuals and those deprived of vision early in life.

  16. High frequency source localization in a shallow ocean sound channel using frequency difference matched field processing.

    Science.gov (United States)

    Worthmann, Brian M; Song, H C; Dowling, David R

    2015-12-01

    Matched field processing (MFP) is an established technique for source localization in known multipath acoustic environments. Unfortunately, in many situations, particularly those involving high frequency signals, imperfect knowledge of the actual propagation environment prevents accurate propagation modeling and source localization via MFP fails. For beamforming applications, this actual-to-model mismatch problem was mitigated through a frequency downshift, made possible by a nonlinear array-signal-processing technique called frequency difference beamforming [Abadi, Song, and Dowling (2012). J. Acoust. Soc. Am. 132, 3018-3029]. Here, this technique is extended to conventional (Bartlett) MFP using simulations and measurements from the 2011 Kauai Acoustic Communications MURI experiment (KAM11) to produce ambiguity surfaces at frequencies well below the signal bandwidth where the detrimental effects of mismatch are reduced. Both the simulation and experimental results suggest that frequency difference MFP can be more robust against environmental mismatch than conventional MFP. In particular, signals of frequency 11.2 kHz-32.8 kHz were broadcast 3 km through a 106-m-deep shallow ocean sound channel to a sparse 16-element vertical receiving array. Frequency difference MFP unambiguously localized the source in several experimental data sets with average peak-to-side-lobe ratio of 0.9 dB, average absolute-value range error of 170 m, and average absolute-value depth error of 10 m.

  17. 38 CFR 4.76 - Visual acuity.

    Science.gov (United States)

    2010-07-01

    ... DISABILITIES Disability Ratings The Organs of Special Sense § 4.76 Visual acuity. (a) Examination of visual acuity. Examination of visual acuity must include the central uncorrected and corrected visual acuity for... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Visual acuity. 4.76...

  18. The effect of multimicrophone noise reduction systems on sound source localization by users of binaural hearing aids.

    Science.gov (United States)

    Van den Bogaert, Tim; Doclo, Simon; Wouters, Jan; Moonen, Marc

    2008-07-01

    This paper evaluates the influence of three multimicrophone noise reduction algorithms on the ability to localize sound sources. Two recently developed noise reduction techniques for binaural hearing aids were evaluated, namely, the binaural multichannel Wiener filter (MWF) and the binaural multichannel Wiener filter with partial noise estimate (MWF-N), together with a dual-monaural adaptive directional microphone (ADM), which is a widely used noise reduction approach in commercial hearing aids. The influence of the different algorithms on perceived sound source localization and their noise reduction performance was evaluated. It is shown that noise reduction algorithms can have a large influence on localization and that (a) the ADM only preserves localization in the forward direction over azimuths where limited or no noise reduction is obtained; (b) the MWF preserves localization of the target speech component but may distort localization of the noise component. The latter is dependent on signal-to-noise ratio and masking effects; (c) the MWF-N enables correct localization of both the speech and the noise components; (d) the statistical Wiener filter approach introduces a better combination of sound source localization and noise reduction performance than the ADM approach.

  19. Contribution of monaural and binaural cues to sound localization in listeners with acquired unilateral conductive hearing loss: improved directional hearing with a bone-conduction device.

    Science.gov (United States)

    Agterberg, Martijn J H; Snik, Ad F M; Hol, Myrthe K S; Van Wanrooij, Marc M; Van Opstal, A John

    2012-04-01

    Sound localization in the horizontal (azimuth) plane relies mainly on interaural time differences (ITDs) and interaural level differences (ILDs). Both are distorted in listeners with acquired unilateral conductive hearing loss (UCHL), reducing their ability to localize sound. Several studies demonstrated that UCHL listeners had some ability to localize sound in azimuth. To test whether listeners with acquired UCHL use strongly perturbed binaural difference cues, we measured localization while they listened with a sound-attenuating earmuff over their impaired ear. We also tested the potential use of monaural pinna-induced spectral-shape cues for localization in azimuth and elevation, by filling the cavities of the pinna of their better-hearing ear with a mould. These conditions were tested while a bone-conduction device (BCD), fitted to all UCHL listeners in order to provide hearing from the impaired side, was turned off. We varied stimulus presentation levels to investigate whether UCHL listeners were using sound level as an azimuth cue. Furthermore, we examined whether horizontal sound-localization abilities improved when listeners used their BCD. Ten control listeners without hearing loss demonstrated a significant decrease in their localization abilities when they listened with a monaural plug and muff. In 4/13 UCHL listeners we observed good horizontal localization of 65 dB SPL broadband noises with their BCD turned off. Localization was strongly impaired when the impaired ear was covered with the muff. The mould in the good ear of listeners with UCHL deteriorated the localization of broadband sounds presented at 45 dB SPL. This demonstrates that they used pinna cues to localize sounds presented at low levels. Our data demonstrate that UCHL listeners have learned to adapt their localization strategies under a wide variety of hearing conditions and that sound-localization abilities improved with their BCD turned on.

  20. Localizing semantic interference from distractor sounds in picture naming: A dual-task study.

    Science.gov (United States)

    Mädebach, Andreas; Kieseler, Marie-Luise; Jescheniak, Jörg D

    2017-10-13

    In this study we explored the locus of semantic interference in a novel picture-sound interference task in which participants name pictures while ignoring environmental distractor sounds. In a previous study using this task (Mädebach, Wöhner, Kieseler, & Jescheniak, in Journal of Experimental Psychology: Human Perception and Performance, 43, 1629-1646, 2017), we showed that semantically related distractor sounds (e.g., BARKING dog ) interfere with a picture-naming response (e.g., "horse") more strongly than unrelated distractor sounds do (e.g., DRUMMING drum ). In the experiment reported here, we employed the psychological refractory period (PRP) approach to explore the locus of this effect. We combined a geometric form classification task (square vs. circle; Task 1) with the picture-sound interference task (Task 2). The stimulus onset asynchrony (SOA) between the tasks was systematically varied (0 vs. 500 ms). There were three central findings. First, the semantic interference effect from distractor sounds was replicated. Second, picture naming (in Task 2) was slower with the short than with the long task SOA. Third, both effects were additive-that is, the semantic interference effects were of similar magnitude at both task SOAs. This suggests that the interference arises during response selection or later stages, not during early perceptual processing. This finding corroborates the theory that semantic interference from distractor sounds reflects a competitive selection mechanism in word production.

  1. Effects of Active and Passive Hearing Protection Devices on Sound Source Localization, Speech Recognition, and Tone Detection.

    Directory of Open Access Journals (Sweden)

    Andrew D Brown

    Full Text Available Hearing protection devices (HPDs such as earplugs offer to mitigate noise exposure and reduce the incidence of hearing loss among persons frequently exposed to intense sound. However, distortions of spatial acoustic information and reduced audibility of low-intensity sounds caused by many existing HPDs can make their use untenable in high-risk (e.g., military or law enforcement environments where auditory situational awareness is imperative. Here we assessed (1 sound source localization accuracy using a head-turning paradigm, (2 speech-in-noise recognition using a modified version of the QuickSIN test, and (3 tone detection thresholds using a two-alternative forced-choice task. Subjects were 10 young normal-hearing males. Four different HPDs were tested (two active, two passive, including two new and previously untested devices. Relative to unoccluded (control performance, all tested HPDs significantly degraded performance across tasks, although one active HPD slightly improved high-frequency tone detection thresholds and did not degrade speech recognition. Behavioral data were examined with respect to head-related transfer functions measured using a binaural manikin with and without tested HPDs in place. Data reinforce previous reports that HPDs significantly compromise a variety of auditory perceptual facilities, particularly sound localization due to distortions of high-frequency spectral cues that are important for the avoidance of front-back confusions.

  2. What and Where in auditory sensory processing: A high-density electrical mapping study of distinct neural processes underlying sound object recognition and sound localization

    Directory of Open Access Journals (Sweden)

    Victoria M Leavitt

    2011-06-01

    Full Text Available Functionally distinct dorsal and ventral auditory pathways for sound localization (where and sound object recognition (what have been described in non-human primates. A handful of studies have explored differential processing within these streams in humans, with highly inconsistent findings. Stimuli employed have included simple tones, noise bursts and speech sounds, with simulated left-right spatial manipulations, and in some cases participants were not required to actively discriminate the stimuli. Our contention is that these paradigms were not well suited to dissociating processing within the two streams. Our aim here was to determine how early in processing we could find evidence for dissociable pathways using better titrated what and where task conditions. The use of more compelling tasks should allow us to amplify differential processing within the dorsal and ventral pathways. We employed high-density electrical mapping using a relatively large and environmentally realistic stimulus set (seven animal calls delivered from seven free-field spatial locations; with stimulus configuration identical across the where and what tasks. Topographic analysis revealed distinct dorsal and ventral auditory processing networks during the where and what tasks with the earliest point of divergence seen during the N1 component of the auditory evoked response, beginning at approximately 100 ms. While this difference occurred during the N1 timeframe, it was not a simple modulation of N1 amplitude as it displayed a wholly different topographic distribution to that of the N1. Global dissimilarity measures using topographic modulation analysis confirmed that this difference between tasks was driven by a shift in the underlying generator configuration. Minimum norm source reconstruction revealed distinct activations that corresponded well with activity within putative dorsal and ventral auditory structures.

  3. Local Mechanisms for Loud Sound-Enhanced Aminoglycoside Entry into Outer Hair Cells

    Directory of Open Access Journals (Sweden)

    Hongzhe eLi

    2015-04-01

    Full Text Available Loud sound exposure exacerbates aminoglycoside ototoxicity, increasing the risk of permanent hearing loss and degrading the quality of life in affected individuals. We previously reported that loud sound exposure induces temporary threshold shifts (TTS and enhances uptake of aminoglycosides, like gentamicin, by cochlear outer hair cells (OHCs. Here, we explore mechanisms by which loud sound exposure and TTS could increase aminoglycoside uptake by OHCs that may underlie this form of ototoxic synergy.Mice were exposed to loud sound levels to induce TTS, and received fluorescently-tagged gentamicin (GTTR for 30 minutes prior to fixation. The degree of TTS was assessed by comparing auditory brainstem responses before and after loud sound exposure. The number of tip links, which gate the GTTR-permeant mechanoelectrical transducer (MET channels, was determined in OHC bundles, with or without exposure to loud sound, using scanning electron microscopy.We found wide-band noise (WBN levels that induce TTS also enhance OHC uptake of GTTR compared to OHCs in control cochleae. In cochlear regions with TTS, the increase in OHC uptake of GTTR was significantly greater than in adjacent pillar cells. In control mice, we identified stereociliary tip links at ~50% of potential positions in OHC bundles. However, the number of OHC tip links was significantly reduced in mice that received WBN at levels capable of inducing TTS.These data suggest that GTTR uptake by OHCs during TTS occurs by increased permeation of surviving, mechanically-gated MET channels, and/or non-MET aminoglycoside-permeant channels activated following loud sound exposure. Loss of tip links would hyperpolarize hair cells and potentially increase drug uptake via aminoglycoside-permeant channels expressed by hair cells. The effect of TTS on aminoglycoside-permeant channel kinetics will shed new light on the mechanisms of loud sound-enhanced aminoglycoside uptake, and consequently on ototoxic

  4. A "looming bias" in spatial hearing? Effects of acoustic intensity and spectrum on categorical sound source localization.

    Science.gov (United States)

    McCarthy, Lisa; Olsen, Kirk N

    2017-01-01

    Continuous increases of acoustic intensity (up-ramps) can indicate a looming (approaching) sound source in the environment, whereas continuous decreases of intensity (down-ramps) can indicate a receding sound source. From psychoacoustic experiments, an "adaptive perceptual bias" for up-ramp looming tonal stimuli has been proposed (Neuhoff, 1998). This theory postulates that (1) up-ramps are perceptually salient because of their association with looming and potentially threatening stimuli in the environment; (2) tonal stimuli are perceptually salient because of an association with single and potentially threatening biological sound sources in the environment, relative to white noise, which is more likely to arise from dispersed signals and nonthreatening/nonbiological sources (wind/ocean). In the present study, we extrapolated the "adaptive perceptual bias" theory and investigated its assumptions by measuring sound source localization in response to acoustic stimuli presented in azimuth to imply looming, stationary, and receding motion in depth. Participants (N = 26) heard three directions of intensity change (up-ramps, down-ramps, and steady state, associated with looming, receding, and stationary motion, respectively) and three levels of acoustic spectrum (a 1-kHz pure tone, the tonal vowel /ә/, and white noise) in a within-subjects design. We first hypothesized that if up-ramps are "perceptually salient" and capable of eliciting adaptive responses, then they would be localized faster and more accurately than down-ramps. This hypothesis was supported. However, the results did not support the second hypothesis. Rather, the white-noise and vowel conditions were localized faster and more accurately than the pure-tone conditions. These results are discussed in the context of auditory and visual theories of motion perception, auditory attentional capture, and the spectral causes of spatial ambiguity.

  5. Experimental analysis of considering the sound pressure distribution pattern at the ear canal entrance as an unrevealed head-related localization clue

    Institute of Scientific and Technical Information of China (English)

    TONG Xin; QI Na; MENG Zihou

    2018-01-01

    By analyzing the differences between binaural recording and real listening,it was deduced that there were some unrevealed auditory localization clues,and the sound pressure distribution pattern at the entrance of ear canal was probably a clue.It was proved through the listening test that the unrevealed auditory localization clues really exist with the reduction to absurdity.And the effective frequency bands of the unrevealed localization clues were induced and summed.The result of finite element based simulations showed that the pressure distribution at the entrance of ear canal was non-uniform,and the pattern was related to the direction of sound source.And it was proved that the sound pressure distribution pattern at the entrance of the ear canal carried the sound source direction information and could be used as an unrevealed localization cluc.The frequency bands in which the sound pressure distribution patterns had significant differences between front and back sound source directions were roughly matched with the effective frequency bands of unrevealed localization clues obtained from the listening tests.To some extent,it supports the hypothesis that the sound pressure distribution pattern could be a kind of unrevealed auditory localization clues.

  6. Ionospheric Electron Densities at Mars: Comparison of Mars Express Ionospheric Sounding and MAVEN Local Measurement

    Czech Academy of Sciences Publication Activity Database

    Němec, F.; Morgan, D. D.; Fowler, C.M.; Kopf, A.J.; Andersson, L.; Gurnett, D. A.; Andrews, D.J.; Truhlík, Vladimír

    2017-01-01

    Roč. 122, č. 12 (2017), s. 12393-12405 E-ISSN 2169-9402 Institutional support: RVO:68378289 Keywords : Mars * ionosphere * MARSIS * Mars Express * MAVEN * radar sounding Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) http://onlinelibrary.wiley.com/doi/10.1002/2017JA024629/full

  7. Hoeren unter Wasser: Absolute Reizschwellen und Richtungswahrnehnumg (Underwater Hearing: Absolute Thresholds and Sound Localization),

    Science.gov (United States)

    The article deals first with the theoretical foundations of underwater hearing, and the effects of the acoustical characteristics of water on hearing...lead to the conclusion that, in water , man can locate the direction of sound at low and at very high tonal frequencies of the audio range, but this ability is probably vanishing in the middle range of frequencies. (Author)

  8. The Effect of Microphone Placement on Interaural Level Differences and Sound Localization Across the Horizontal Plane in Bilateral Cochlear Implant Users.

    Science.gov (United States)

    Jones, Heath G; Kan, Alan; Litovsky, Ruth Y

    2016-01-01

    This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for microphones placed in the ear (ITE), behind the ear (BTE), and on the shoulders (SHD). The ILDs across source locations were calculated for each placement to analyze their effect on sound localization performance. Sound localization was tested using a repeated-measures, within-participant design for the three microphone placements. The ITE microphone placement provided significantly larger ILDs compared to BTE and SHD placements, which correlated with overall localization errors. However, differences in localization errors across the microphone conditions were small. The BTE microphones worn by many BiCI users in everyday life do not capture the full range of acoustic ILDs available, and also reduce the change in cue magnitudes for sound sources across the horizontal plane. Acute testing with an ITE placement reduced sound localization errors along the horizontal plane compared to the other placements in some patients. Larger improvements may be observed if patients had more experience with the new ILD cues provided by an ITE placement.

  9. Noise source separation of diesel engine by combining binaural sound localization method and blind source separation method

    Science.gov (United States)

    Yao, Jiachi; Xiang, Yang; Qian, Sichong; Li, Shengyang; Wu, Shaowei

    2017-11-01

    In order to separate and identify the combustion noise and the piston slap noise of a diesel engine, a noise source separation and identification method that combines a binaural sound localization method and blind source separation method is proposed. During a diesel engine noise and vibration test, because a diesel engine has many complex noise sources, a lead covering method was carried out on a diesel engine to isolate other interference noise from the No. 1-5 cylinders. Only the No. 6 cylinder parts were left bare. Two microphones that simulated the human ears were utilized to measure the radiated noise signals 1 m away from the diesel engine. First, a binaural sound localization method was adopted to separate the noise sources that are in different places. Then, for noise sources that are in the same place, a blind source separation method is utilized to further separate and identify the noise sources. Finally, a coherence function method, continuous wavelet time-frequency analysis method, and prior knowledge of the diesel engine are combined to further identify the separation results. The results show that the proposed method can effectively separate and identify the combustion noise and the piston slap noise of a diesel engine. The frequency of the combustion noise and the piston slap noise are respectively concentrated at 4350 Hz and 1988 Hz. Compared with the blind source separation method, the proposed method has superior separation and identification effects, and the separation results have fewer interference components from other noise.

  10. Auditory disorders and acquisition of the ability to localize sound in children born to HIV-positive mothers

    Directory of Open Access Journals (Sweden)

    Carla Gentile Matas

    Full Text Available The objective of the present study was to evaluate children born to HIV-infected mothers and to determine whether such children present auditory disorders or poor acquisition of the ability to localize sound. The population studied included 143 children (82 males and 61 females, ranging in age from one month to 30 months. The children were divided into three groups according to the classification system devised in 1994 by the Centers for Disease Control and Prevention: infected; seroreverted; and exposed. The children were then submitted to audiological evaluation, including behavioral audiometry, visual reinforcement audiometry and measurement of acoustic immittance. Statistical analysis showed that the incidence of auditory disorders was significantly higher in the infected group. In the seroreverted and exposed groups, there was a marked absence of auditory disorders. In the infected group as a whole, the findings were suggestive of central auditory disorders. Evolution of the ability to localize sound was found to be poorer among the children in the infected group than among those in the seroreverted and exposed groups.

  11. Effects of user training with electronically-modulated sound transmission hearing protectors and the open ear on horizontal localization ability.

    Science.gov (United States)

    Casali, John G; Robinette, Martin B

    2015-02-01

    To determine if training with electronically-modulated hearing protection (EMHP) and the open ear results in auditory learning on a horizontal localization task. Baseline localization testing was conducted in three listening conditions (open-ear, in-the-ear (ITE) EMHP, and over-the-ear (OTE) EMHP). Participants then wore either an ITE or OTE EMHP for 12, almost daily, one-hour training sessions. After training was complete, participants again underwent localization testing in all three listening conditions. A computer with a custom software and hardware interface presented localization sounds and collected participant responses. Twelve participants were recruited from the student population at Virginia Tech. Audiometric requirements were 35 dBHL at 500, 1000, and 2000 Hz bilaterally, and 55 dBHL at 4000 Hz in at least one ear. Pre-training localization performance with an ITE or OTE EMHP was worse than open-ear performance. After training with any given listening condition, including open-ear, performance in that listening condition improved, in part from a practice effect. However, post-training localization performance showed near equal performance between the open-ear and training EMHP. Auditory learning occurred for the training EMHP, but not for the non-training EMHP; that is, there was no significant training crossover effect between the ITE and the OTE devices. It is evident from this study that auditory learning (improved horizontal localization performance) occurred with the EMHP for which training was performed. However, performance improvements found with the training EMHP were not realized in the non-training EMHP. Furthermore, localization performance in the open-ear condition also benefitted from training on the task.

  12. Predicting visual acuity from detection thresholds.

    Science.gov (United States)

    Newacheck, J S; Haegerstrom-Portnoy, G; Adams, A J

    1990-03-01

    Visual performance based exclusively on high luminance and high contrast letter acuity measures often fails to predict individual performance at low contrast and low luminance. Here we measured visual acuity over a wide range of contrasts and luminances (low mesopic to photopic) for 17 young normal observers. Acuity vs. contrast functions appear to fit a single template which can be displaced laterally along the log contrast axis. The magnitude of this lateral displacement for different luminances was well predicted by the contrast threshold difference for a 4 min arc spot. The acuity vs. contrast template, taken from the mean of all 17 subjects, was used in conjunction with individual spot contrast threshold measures to predict an individual's visual acuity over a wide range of luminance and contrast levels. The accuracy of the visual acuity predictions from this simple procedure closely approximates test-retest accuracy for both positive (projected Landolt rings) and negative contrast (Bailey-Lovie charts).

  13. Sound and sound sources

    DEFF Research Database (Denmark)

    Larsen, Ole Næsbye; Wahlberg, Magnus

    2017-01-01

    There is no difference in principle between the infrasonic and ultrasonic sounds, which are inaudible to humans (or other animals) and the sounds that we can hear. In all cases, sound is a wave of pressure and particle oscillations propagating through an elastic medium, such as air. This chapter...... is about the physical laws that govern how animals produce sound signals and how physical principles determine the signals’ frequency content and sound level, the nature of the sound field (sound pressure versus particle vibrations) as well as directional properties of the emitted signal. Many...... of these properties are dictated by simple physical relationships between the size of the sound emitter and the wavelength of emitted sound. The wavelengths of the signals need to be sufficiently short in relation to the size of the emitter to allow for the efficient production of propagating sound pressure waves...

  14. 77 FR 33967 - Special Local Regulations; OPSAIL 2012 Connecticut, Niantic Bay, Long Island Sound, Thames River...

    Science.gov (United States)

    2012-06-08

    ..., Operation Sail, Inc., is planning to publish information on the event in local newspapers, internet sites... areas for viewing the ``Parade of Sail'' have been established to allow for maximum use of the waterways... SLIS or designated representative. Before the effective period, the Coast Guard will make notifications...

  15. 76 FR 39292 - Special Local Regulations & Safety Zones; Marine Events in Captain of the Port Long Island Sound...

    Science.gov (United States)

    2011-07-06

    ... Port Long Island Sound Zone AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast... and fireworks displays within the Captain of the Port (COTP) Long Island Sound Zone. This action is... Island Sound. DATES: This rule is effective in the CFR on July 6, 2011 through 6 p.m. on October 2, 2011...

  16. Using ILD or ITD Cues for Sound Source Localization and Speech Understanding in a Complex Listening Environment by Listeners with Bilateral and with Hearing-Preservation Cochlear Implants

    Science.gov (United States)

    Loiselle, Louise H.; Dorman, Michael F.; Yost, William A.; Cook, Sarah J.; Gifford, Rene H.

    2016-01-01

    Purpose: To assess the role of interaural time differences and interaural level differences in (a) sound-source localization, and (b) speech understanding in a cocktail party listening environment for listeners with bilateral cochlear implants (CIs) and for listeners with hearing-preservation CIs. Methods: Eleven bilateral listeners with MED-EL…

  17. Human locognosic acuity on the arm varies with explicit and implicit manipulations of attention: implications for interpreting elevated tactile acuity on an amputation stump.

    Science.gov (United States)

    O'Boyle, D J; Moore, C E; Poliakoff, E; Butterworth, R; Sutton, A; Cody, F W

    2001-06-01

    In Experiment 1, normal subjects' ability to localize tactile stimuli (locognosia) delivered to the upper arm was significantly higher when they were instructed explicitly to direct their attention selectively to that segment than when they were instructed explicitly to distribute their attention across the whole arm. This elevation of acuity was eliminated when subjects' attentional resources were divided by superimposition of an effortful, secondary task during stimulation. In Experiment 2, in the absence of explicit attentional instruction, subjects' locognosic acuity on one of three arm segments was significantly higher when stimulation of that segment was 2.5 times more probable than that of stimulation of the other two segments. We surmise that the attentional mechanisms responsible for such modulations of locognosic acuity in normal subjects may contribute to the elevated sensory acuity observed on the stumps of amputees.

  18. The stability of second sound waves in a rotating Darcy–Brinkman porous layer in local thermal non-equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Eltayeb, I A; Elbashir, T B A, E-mail: ieltayeb@squ.edu.om, E-mail: elbashir@squ.edu.om [Department of Mathematics and Statistics, College of Science, Sultan Qaboos University, Muscat 123 (Oman)

    2017-08-15

    The linear and nonlinear stabilities of second sound waves in a rotating porous Darcy–Brinkman layer in local thermal non-equilibrium are studied when the heat flux in the solid obeys the Cattaneo law. The simultaneous action of the Brinkman effect (effective viscosity) and rotation is shown to destabilise the layer, as compared to either of them acting alone, for both stationary and overstable modes. The effective viscosity tends to favour overstable modes while rotation tends to favour stationary convection. Rapid rotation invokes a negative viscosity effect that suppresses the stabilising effect of porosity so that the stability characteristics resemble those of the classical rotating Benard layer. A formal weakly nonlinear analysis yields evolution equations of the Landau–Stuart type governing the slow time development of the amplitudes of the unstable waves. The equilibrium points of the evolution equations are analysed and the overall development of the amplitudes is examined. Both overstable and stationary modes can exhibit supercritical stability; supercritical instability, subcritical instability and stability are not possible. The dependence of the supercritical stability on the relative values of the six dimensionless parameters representing thermal non-equilibrium, rotation, porosity, relaxation time, thermal diffusivities and Brinkman effect is illustrated as regions in regime diagrams in the parameter space. The dependence of the heat transfer and the mean heat flux on the parameters of the problem is also discussed. (paper)

  19. Contribution of a 3D ray tracing model in a complex medium to the localization of infra-sound sources

    International Nuclear Information System (INIS)

    Mialle, Pierrick

    2007-01-01

    Localisation of infra-sound sources is a difficult task due to large propagation distances at stake and because of the atmospheric complexity. In order to resolve this problem, one can seek as many necessary information as the comprehension of wave propagation, the role and influence of the atmosphere and its spatio-temporal variations, the knowledge of sources and detection parameters, but also the configuration of the stations and their global spreading. Two methods based on the construction of propagation tables depending on station, date and time are introduced. Those tables require a long range propagation tool to simulate the propagation through a complex medium, which are carried out by WASP-3D Sph a 3D paraxial ray tracing based-theory tool integrating both amplitude estimation and horizontal wind fields in space and time. Tables are centered on the receptor. They describe spatial variations of the main observation parameters and offer a snapshot of the atmospheric propagation depending on the range for every simulated phase. For each path, celerity, azimuth deviation, attenuation and return altitude are predicted and allow building the tables. The latter help to identify detected phases and are integrated in an accurate localization procedure. The procedure is tested on three case study, such as the explosion of gas-pipeline in Belgium 2004 near Ghislenghien, the explosion of a military facility in 2007 in Novaky, Slovakia and the explosion of the Buncefield oil depot in 2005 in the United Kingdom, where event specificities, propagation parameters and used configurations are introduced. The accuracy and optimization of the localization are discussed. A validation study is presented regarding International Monitoring System stations along a meridian - I18DK (Greenland, Denmark), I51UK (Bermuda, United Kingdom), I25FR (Guyane, France), I08BO (La Paz, Bolivia), I01AR (Paso Flores, Argentina), I02AR (Ushuaia, Argentina), I54US (Antarctica, U.S.A.) - to

  20. Mutation in the kv3.3 voltage-gated potassium channel causing spinocerebellar ataxia 13 disrupts sound-localization mechanisms.

    Directory of Open Access Journals (Sweden)

    John C Middlebrooks

    Full Text Available Normal sound localization requires precise comparisons of sound timing and pressure levels between the two ears. The primary localization cues are interaural time differences, ITD, and interaural level differences, ILD. Voltage-gated potassium channels, including Kv3.3, are highly expressed in the auditory brainstem and are thought to underlie the exquisite temporal precision and rapid spike rates that characterize brainstem binaural pathways. An autosomal dominant mutation in the gene encoding Kv3.3 has been demonstrated in a large Filipino kindred manifesting as spinocerebellar ataxia type 13 (SCA13. This kindred provides a rare opportunity to test in vivo the importance of a specific channel subunit for human hearing. Here, we demonstrate psychophysically that individuals with the mutant allele exhibit profound deficits in both ITD and ILD sensitivity, despite showing no obvious impairment in pure-tone sensitivity with either ear. Surprisingly, several individuals exhibited the auditory deficits even though they were pre-symptomatic for SCA13. We would expect that impairments of binaural processing as great as those observed in this family would result in prominent deficits in localization of sound sources and in loss of the "spatial release from masking" that aids in understanding speech in the presence of competing sounds.

  1. The influence of signal parameters on the sound source localization ability of a harbor porpoise (Phocoena phocoena)

    NARCIS (Netherlands)

    Kastelein, R.A.; Haan, D.de; Verboom, W.C.

    2007-01-01

    It is unclear how well harbor porpoises can locate sound sources, and thus can locate acoustic alarms on gillnets. Therefore the ability of a porpoise to determine the location of a sound source was determined. The animal was trained to indicate the active one of 16 transducers in a 16-m -diam

  2. Comparison between bilateral cochlear implants and Neurelec Digisonic(®) SP Binaural cochlear implant: speech perception, sound localization and patient self-assessment.

    Science.gov (United States)

    Bonnard, Damien; Lautissier, Sylvie; Bosset-Audoit, Amélie; Coriat, Géraldine; Beraha, Max; Maunoury, Antoine; Martel, Jacques; Darrouzet, Vincent; Bébéar, Jean-Pierre; Dauman, René

    2013-01-01

    An alternative to bilateral cochlear implantation is offered by the Neurelec Digisonic(®) SP Binaural cochlear implant, which allows stimulation of both cochleae within a single device. The purpose of this prospective study was to compare a group of Neurelec Digisonic(®) SP Binaural implant users (denoted BINAURAL group, n = 7) with a group of bilateral adult cochlear implant users (denoted BILATERAL group, n = 6) in terms of speech perception, sound localization, and self-assessment of health status and hearing disability. Speech perception was assessed using word recognition at 60 dB SPL in quiet and in a 'cocktail party' noise delivered through five loudspeakers in the hemi-sound field facing the patient (signal-to-noise ratio = +10 dB). The sound localization task was to determine the source of a sound stimulus among five speakers positioned between -90° and +90° from midline. Change in health status was assessed using the Glasgow Benefit Inventory and hearing disability was evaluated with the Abbreviated Profile of Hearing Aid Benefit. Speech perception was not statistically different between the two groups, even though there was a trend in favor of the BINAURAL group (mean percent word recognition in the BINAURAL and BILATERAL groups: 70 vs. 56.7% in quiet, 55.7 vs. 43.3% in noise). There was also no significant difference with regard to performance in sound localization and self-assessment of health status and hearing disability. On the basis of the BINAURAL group's performance in hearing tasks involving the detection of interaural differences, implantation with the Neurelec Digisonic(®) SP Binaural implant may be considered to restore effective binaural hearing. Based on these first comparative results, this device seems to provide benefits similar to those of traditional bilateral cochlear implantation, with a new approach to stimulate both auditory nerves. Copyright © 2013 S. Karger AG, Basel.

  3. Assessment of Grating Acuity in Infants and Toddlers Using an Electronic Acuity Card: The Dobson Card.

    Science.gov (United States)

    Mohan, Kathleen M; Miller, Joseph M; Harvey, Erin M; Gerhart, Kimberly D; Apple, Howard P; Apple, Deborah; Smith, Jordana M; Davis, Amy L; Leonard-Green, Tina; Campus, Irene; Dennis, Leslie K

    2016-01-01

    To determine if testing binocular visual acuity in infants and toddlers using the Acuity Card Procedure (ACP) with electronic grating stimuli yields clinically useful data. Participants were infants and toddlers ages 5 to 36.7 months referred by pediatricians due to failed automated vision screening. The ACP was used to test binocular grating acuity. Stimuli were presented on the Dobson Card. The Dobson Card consists of a handheld matte-black plexiglass frame with two flush-mounted tablet computers and is similar in size and form to commercially available printed grating acuity testing stimuli (Teller Acuity Cards II [TACII]; Stereo Optical, Inc., Chicago, IL). On each trial, one tablet displayed a square-wave grating and the other displayed a luminance-matched uniform gray patch. Stimuli were roughly equivalent to the stimuli available in the printed TACII stimuli. After acuity testing, each child received a cycloplegic eye examination. Based on cycloplegic retinoscopy, patients were categorized as having high or low refractive error per American Association for Pediatric Ophthalmology and Strabismus vision screening referral criteria. Mean acuities for high and low refractive error groups were compared using analysis of covariance, controlling for age. Mean visual acuity was significantly poorer in children with high refractive error than in those with low refractive error (P = .015). Electronic stimuli presented using the ACP can yield clinically useful measurements of grating acuity in infants and toddlers. Further research is needed to determine the optimal conditions and procedures for obtaining accurate and clinically useful automated measurements of visual acuity in infants and toddlers. Copyright 2016, SLACK Incorporated.

  4. Improvements of sound localization abilities by the facial ruff of the barn owl (Tyto alba as demonstrated by virtual ruff removal.

    Directory of Open Access Journals (Sweden)

    Laura Hausmann

    Full Text Available BACKGROUND: When sound arrives at the eardrum it has already been filtered by the body, head, and outer ear. This process is mathematically described by the head-related transfer functions (HRTFs, which are characteristic for the spatial position of a sound source and for the individual ear. HRTFs in the barn owl (Tyto alba are also shaped by the facial ruff, a specialization that alters interaural time differences (ITD, interaural intensity differences (ILD, and the frequency spectrum of the incoming sound to improve sound localization. Here we created novel stimuli to simulate the removal of the barn owl's ruff in a virtual acoustic environment, thus creating a situation similar to passive listening in other animals, and used these stimuli in behavioral tests. METHODOLOGY/PRINCIPAL FINDINGS: HRTFs were recorded from an owl before and after removal of the ruff feathers. Normal and ruff-removed conditions were created by filtering broadband noise with the HRTFs. Under normal virtual conditions, no differences in azimuthal head-turning behavior between individualized and non-individualized HRTFs were observed. The owls were able to respond differently to stimuli from the back than to stimuli from the front having the same ITD. By contrast, such a discrimination was not possible after the virtual removal of the ruff. Elevational head-turn angles were (slightly smaller with non-individualized than with individualized HRTFs. The removal of the ruff resulted in a large decrease in elevational head-turning amplitudes. CONCLUSIONS/SIGNIFICANCE: The facial ruff a improves azimuthal sound localization by increasing the ITD range and b improves elevational sound localization in the frontal field by introducing a shift of iso-ILD lines out of the midsagittal plane, which causes ILDs to increase with increasing stimulus elevation. The changes at the behavioral level could be related to the changes in the binaural physical parameters that occurred after the

  5. How to measure distance visual acuity

    Directory of Open Access Journals (Sweden)

    Janet Marsden

    2014-04-01

    Full Text Available Visual acuity (VA is a measure of the ability of the eye to distinguish shapes and the details of objects at a given distance. It is important to assess VA in a consistent way in order to detect any changes in vision. One eye is tested at a time.

  6. Sound algorithms

    OpenAIRE

    De Götzen , Amalia; Mion , Luca; Tache , Olivier

    2007-01-01

    International audience; We call sound algorithms the categories of algorithms that deal with digital sound signal. Sound algorithms appeared in the very infancy of computer. Sound algorithms present strong specificities that are the consequence of two dual considerations: the properties of the digital sound signal itself and its uses, and the properties of auditory perception.

  7. Buccal mucosal cancer patient who failed to recover taste acuity after partial oral cavity irradiation

    International Nuclear Information System (INIS)

    Saito, Tsutomu; Fukushima, Shoko; Furuhashi, Satoru; Yoshinobu, Takashi; Takahashi, Motoichiro; Miyake, Masahiko; Kawamori, Jiro; Tanaka, Yoshiaki

    2002-01-01

    We report a patient who suffered from prolonged loss of taste acuity after partial oral cavity irradiation. The electric taste threshold (ETT) of each point in the oral cavity was measured with an electric gustometer to evaluate quantitative local taste acuity. A subjective total taste acuity (STTA) scale was used to evaluate subjective total taste acuity. A 61-year-old male patient with right buccal mucosal cancer underwent radiation therapy more than 11 years ago, and has suffered from loss of taste acuity since then. He received electron beam irradiation to part of the oral cavity and right upper neck, mainly the right buccal mucosa near the retromolar trigone and a metastatic right submandibular node. He did not receive irradiation to the anterior portion of the tongue or left side of the posterior portion of the tongue. His ETT scores for each point were equal to or greater than 26, and his STTA score was grade 3. The present case implies that radiation damage to part of the oral cavity can cause the loss of subjective total taste acuity. (author)

  8. Buccal mucosal cancer patient who failed to recover taste acuity after partial oral cavity irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Tsutomu; Fukushima, Shoko; Furuhashi, Satoru; Yoshinobu, Takashi; Takahashi, Motoichiro [Nihon Univ., Tokyo (Japan). Surugadai Hospital; Miyake, Masahiko [Nihon Univ., Tokyo (Japan). School of Dentistry; Kawamori, Jiro; Tanaka, Yoshiaki [Nihon Univ., Tokyo (Japan). School of Medicine

    2002-10-01

    We report a patient who suffered from prolonged loss of taste acuity after partial oral cavity irradiation. The electric taste threshold (ETT) of each point in the oral cavity was measured with an electric gustometer to evaluate quantitative local taste acuity. A subjective total taste acuity (STTA) scale was used to evaluate subjective total taste acuity. A 61-year-old male patient with right buccal mucosal cancer underwent radiation therapy more than 11 years ago, and has suffered from loss of taste acuity since then. He received electron beam irradiation to part of the oral cavity and right upper neck, mainly the right buccal mucosa near the retromolar trigone and a metastatic right submandibular node. He did not receive irradiation to the anterior portion of the tongue or left side of the posterior portion of the tongue. His ETT scores for each point were equal to or greater than 26, and his STTA score was grade 3. The present case implies that radiation damage to part of the oral cavity can cause the loss of subjective total taste acuity. (author)

  9. Variable acuity remote viewing system flight demonstration

    Science.gov (United States)

    Fisher, R. W.

    1983-01-01

    The Variable Acuity Remote Viewing System (VARVS), originally developed under contract to the Navy (ONR) as a laboratory brassboard, was modified for flight demonstration. The VARVS system was originally conceived as a technique which could circumvent the acuity/field of view/bandwidth tradeoffs that exists in remote viewing to provide a nearly eye limited display in both field of view (160 deg) and resolution (2 min arc) while utilizing conventional TV sensing, transmission, and display equipment. The modifications for flight demonstration consisted of modifying the sensor so it could be installed and flow in a Piper PA20 aircraft, equipped for remote control and modifying the display equipment so it could be integrated with the NASA Research RPB (RPRV) remote control cockpit.

  10. Three-year experience with the Sophono in children with congenital conductive unilateral hearing loss: tolerability, audiometry, and sound localization compared to a bone-anchored hearing aid.

    Science.gov (United States)

    Nelissen, Rik C; Agterberg, Martijn J H; Hol, Myrthe K S; Snik, Ad F M

    2016-10-01

    Bone conduction devices (BCDs) are advocated as an amplification option for patients with congenital conductive unilateral hearing loss (UHL), while other treatment options could also be considered. The current study compared a transcutaneous BCD (Sophono) with a percutaneous BCD (bone-anchored hearing aid, BAHA) in 12 children with congenital conductive UHL. Tolerability, audiometry, and sound localization abilities with both types of BCD were studied retrospectively. The mean follow-up was 3.6 years for the Sophono users (n = 6) and 4.7 years for the BAHA users (n = 6). In each group, two patients had stopped using their BCD. Tolerability was favorable for the Sophono. Aided thresholds with the Sophono were unsatisfactory, as they did not reach under a mean pure tone average of 30 dB HL. Sound localization generally improved with both the Sophono and the BAHA, although localization abilities did not reach the level of normal hearing children. These findings, together with previously reported outcomes, are important to take into account when counseling patients and their caretakers. The selection of a suitable amplification option should always be made deliberately and on individual basis for each patient in this diverse group of children with congenital conductive UHL.

  11. Visual acuity in adults with Asperger's syndrome: no evidence for "eagle-eyed" vision.

    Science.gov (United States)

    Falkmer, Marita; Stuart, Geoffrey W; Danielsson, Henrik; Bram, Staffan; Lönebrink, Mikael; Falkmer, Torbjörn

    2011-11-01

    Autism spectrum conditions (ASC) are defined by criteria comprising impairments in social interaction and communication. Altered visual perception is one possible and often discussed cause of difficulties in social interaction and social communication. Recently, Ashwin et al. suggested that enhanced ability in local visual processing in ASC was due to superior visual acuity, but that study has been the subject of methodological criticism, placing the findings in doubt. The present study investigated visual acuity thresholds in 24 adults with Asperger's syndrome and compared their results with 25 control subjects with the 2 Meter 2000 Series Revised ETDRS Chart. The distribution of visual acuities within the two groups was highly similar, and none of the participants had superior visual acuity. Superior visual acuity in individuals with Asperger's syndrome could not be established, suggesting that differences in visual perception in ASC are not explained by this factor. A continued search for explanations of superior ability in local visual processing in persons with ASC is therefore warranted. Copyright © 2011 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  12. Foley Sounds vs Real Sounds

    DEFF Research Database (Denmark)

    Trento, Stefano; Götzen, Amalia De

    2011-01-01

    This paper is an initial attempt to study the world of sound effects for motion pictures, also known as Foley sounds. Throughout several audio and audio-video tests we have compared both Foley and real sounds originated by an identical action. The main purpose was to evaluate if sound effects...

  13. Evaluation of contrast visual acuity in patients with retinitis pigmentosa

    Science.gov (United States)

    Oomachi, Kazumi; Ogata, Kazuha; Sugawara, Takeshi; Hagiwara, Akira; Hata, Akira; Yamamoto, Shuichi

    2011-01-01

    Background The purpose of this study was to determine visual acuity at different contrast levels under photopic and mesopic conditions in patients with retinitis pigmentosa. Methods Sixty eyes of 31 normal controls, 92 eyes of 52 patients with retinitis pigmentosa without other ocular disorders (RP-1 group), and 20 eyes of 14 patients with retinitis pigmentosa with cataracts and without other ocular disorders (RP-2 group) were studied. Conventional visual acuity was measured using a conventional Landolt ring chart with 100% contrast and luminance of 150 cd/m2. All of the patients with retinitis pigmentosa had a decimal visual acuity better than 1.0. Contrast visual acuity was measured with the same Landolt ring chart with contrasts of 100% and 10% and under photopic (200 cd/m2) and mesopic (10 cd/m2) conditions. Decimal visual acuities were converted to logMAR units for the analyses. Results The 100% contrast visual acuity and the 10% contrast visual acuity determined under both photopic and mesopic conditions were significantly poorer in both the RP-1 and RP-2 groups than in the controls. The differences between the conventional visual acuity and the 100% contrast visual acuity were significantly greater in the RP-1 and RP-2 groups than in the controls under both photopic and mesopic conditions. The differences between the 100% contrast visual acuity and the 10% contrast visual acuity were not significant among the three groups under photopic and mesopic conditions. Conclusion Contrast visual acuities were greatly reduced in patients with retinitis pigmentosa with relatively well preserved conventional visual acuity, and the contrast visual acuity was largely influenced by ambient light levels in patients with retinitis pigmentosa. Although a longitudinal study for confirmation has to be performed, our findings indicate that contrast visual acuity is a better test to follow changes in visual function in patients with retinitis pigmentosa. PMID:22069346

  14. Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

    Science.gov (United States)

    Livingstone, I A T; Tarbert, C M; Giardini, M E; Bastawrous, A; Middleton, D; Hamilton, R

    2016-01-01

    Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≥ 120 cd/m2) and Weber contrast (≥ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%). Two charts were operating beyond manufacturer's recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out

  15. Photometric Compliance of Tablet Screens and Retro-Illuminated Acuity Charts As Visual Acuity Measurement Devices.

    Directory of Open Access Journals (Sweden)

    I A T Livingstone

    Full Text Available Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc. and three ETDRS (Early Treatment Diabetic Retinopathy Study visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2 providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90% regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%. Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off had adequate mean luminance (≥ 120 cd/m2 and Weber contrast (≥ 90%, but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%. Two charts were operating beyond manufacturer's recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out

  16. High visual acuity revealed in dogs.

    Science.gov (United States)

    Lind, Olle; Milton, Ida; Andersson, Elin; Jensen, Per; Roth, Lina S V

    2017-01-01

    Humans have selectively bred and used dogs over a period of thousands of years, and more recently the dog has become an important model animal for studies in ethology, cognition and genetics. These broad interests warrant careful descriptions of the senses of dogs. Still there is little known about dog vision, especially what dogs can discriminate in different light conditions. We trained and tested whippets, pugs, and a Shetland sheepdog in a two-choice discrimination set-up and show that dogs can discriminate patterns with spatial frequencies between 5.5 and 19.5 cycle per degree (cpd) in the bright light condition (43 cd m-2). This is a higher spatial resolution than has been previously reported although the individual variation in our tests was large. Humans tested in the same set-up reached acuities corresponding to earlier studies, ranging between 32.1 and 44.2 cpd. In the dim light condition (0.0087 cd m-2) the acuity of dogs ranged between 1.8 and 3.5 cpd while in humans, between 5.9 and 9.9 cpd. Thus, humans make visual discrimination of objects from roughly a threefold distance compared to dogs in both bright and dim light.

  17. High visual acuity revealed in dogs.

    Directory of Open Access Journals (Sweden)

    Olle Lind

    Full Text Available Humans have selectively bred and used dogs over a period of thousands of years, and more recently the dog has become an important model animal for studies in ethology, cognition and genetics. These broad interests warrant careful descriptions of the senses of dogs. Still there is little known about dog vision, especially what dogs can discriminate in different light conditions. We trained and tested whippets, pugs, and a Shetland sheepdog in a two-choice discrimination set-up and show that dogs can discriminate patterns with spatial frequencies between 5.5 and 19.5 cycle per degree (cpd in the bright light condition (43 cd m-2. This is a higher spatial resolution than has been previously reported although the individual variation in our tests was large. Humans tested in the same set-up reached acuities corresponding to earlier studies, ranging between 32.1 and 44.2 cpd. In the dim light condition (0.0087 cd m-2 the acuity of dogs ranged between 1.8 and 3.5 cpd while in humans, between 5.9 and 9.9 cpd. Thus, humans make visual discrimination of objects from roughly a threefold distance compared to dogs in both bright and dim light.

  18. Imagining Sound

    DEFF Research Database (Denmark)

    Grimshaw, Mark; Garner, Tom Alexander

    2014-01-01

    We make the case in this essay that sound that is imagined is both a perception and as much a sound as that perceived through external stimulation. To argue this, we look at the evidence from auditory science, neuroscience, and philosophy, briefly present some new conceptual thinking on sound...... that accounts for this view, and then use this to look at what the future might hold in the context of imagining sound and developing technology....

  19. Photovoltaic restoration of sight with high visual acuity

    Science.gov (United States)

    Lorach, Henri; Goetz, Georges; Smith, Richard; Lei, Xin; Mandel, Yossi; Kamins, Theodore; Mathieson, Keith; Huie, Philip; Harris, James; Sher, Alexander; Palanker, Daniel

    2015-01-01

    Patients with retinal degeneration lose sight due to gradual demise of photoreceptors. Electrical stimulation of the surviving retinal neurons provides an alternative route for delivery of visual information. We demonstrate that subretinal arrays with 70 μm photovoltaic pixels provide highly localized stimulation, with electrical and visual receptive fields of comparable sizes in rat retinal ganglion cells. Similarly to normal vision, retinal response to prosthetic stimulation exhibits flicker fusion at high frequencies, adaptation to static images and non-linear spatial summation. In rats with retinal degeneration, these photovoltaic arrays provide spatial resolution of 64 ± 11 μm, corresponding to half of the normal visual acuity in pigmented rats. Ease of implantation of these wireless and modular arrays, combined with their high resolution opens the door to functional restoration of sight. PMID:25915832

  20. Localização sonora em usuários de aparelhos de amplificação sonora individual Sound localization by hearing aid users

    Directory of Open Access Journals (Sweden)

    Paula Cristina Rodrigues

    2010-06-01

    Full Text Available OBJETIVO: comparar o desempenho, no teste de localização de fontes sonoras, de usuários de aparelhos de amplificação sonora individual (AASI do tipo retroauricular e intracanal, com o desempenho de ouvintes normais, nos planos espaciais horizontal e sagital mediano, para as frequências de 500, 2.000 e 4.500 Hz; e correlacionar os acertos no teste de localização sonora com o tempo de uso dos AASI. MÉTODOS: foram testados oito ouvintes normais e 20 usuários de próteses auditivas, subdivididos em dois grupos. Um formado por 10 indivíduos usuários de próteses auditivas do tipo intracanal e o outro grupo formado por 10 usuários de próteses auditivas do tipo retroauricular. Todos foram submetidos ao teste de localização de fontes sonoras, no qual foram apresentados, aleatoriamente, três tipos de ondas quadradas, com frequências fundamentais em 0,5 kHz, 2 kHz e 4,5 kHz, na intensidade de 70 dBA. RESULTADOS: encontrou-se percentuais de acertos médios de 78,4%, 72,2% e 72,9% para os ouvintes normais, em 0,5 kHz, 2 kHz e 4,5 kHz, respectivamente e 40,1%, 39,4% e 41,7% para os usuários de aparelho de amplificação sonora individual. Quanto aos tipos de aparelhos, os usuários do modelo intracanal acertaram a origem da fonte sonora em 47,2% das vezes e os usuários do modelo retroauricular em 37,4% das vezes. Não foi observada correlação entre o percentual de acertos no teste de localização sonora e o tempo de uso da prótese auditiva. CONCLUSÃO: ouvintes normais localizam as fontes sonoras de maneira mais eficiente que os usuários de aparelho de amplificação sonora individual e, dentre estes, os que utilizam o modelo intracanal obtiveram melhor desempenho. Além disso, o tempo de uso não interferiu no desempenho para localizar a origem das fontes sonoras.PURPOSE: to compare the sound localization performance of hearing aids users, with the performance of normal hearing in the horizontal and sagittal planes, at 0.5, 2 and 4

  1. LARA. Localization of an automatized refueling machine by acoustical sounding in breeder reactors - implementation of artificial intelligence techniques

    International Nuclear Information System (INIS)

    Lhuillier, C.; Malvache, P.

    1987-01-01

    The automatic control of the machine which handles the nuclear subassemblies in fast neutron reactors requires autonomous perception and decision tools. An acoustical device allows the machine to position in the work area. Artificial intelligence techniques are implemented to interpret the data: pattern recognition, scene analysis. The localization process is managed by an expert system. 6 refs.; 8 figs

  2. [Schoolchildren's visual acuity in the dynamics of learning].

    Science.gov (United States)

    Bezrukikh, M M; Voinov, V B; Kul'ba, S N; Shurygina, I P

    2014-12-01

    The results of the screening study of the acuity of schoolchildren between 7 and 17 years old living in Rostov Region of the Russian Federation are discussed in the article. The method of computer optometry was used to measure acuity. 93772 pupils, 48621 girls and 45151 boys, from 150 schools participated in this examination. It was found that there is sustained growth of those with low acuity (0,2 and less) among children of both sexes from junior group (7 years) to the senior (17). The signs of the decline in visual acuity among girls (14%) are manifested earlier than in boys (8%). The decline in visual acuity among 7-8-year-old children is about 3%. While comparing children from rural areas with those from big cities a true dependence of the parameter (acuity) on the factors (city and sex) was found.

  3. Visual acuity in pelagic fishes and mollusks.

    Science.gov (United States)

    Gagnon, Yakir L; Sutton, Tracey T; Johnsen, Sönke

    2013-11-01

    In the sea, visual scenes change dramatically with depth. At shallow and moderate depths (cephalopods, and a gastropod using a custom-built apparatus. The hatchetfishes (Argyropelecus aculeatus and Sternoptyx diaphana) and the barrel-eye (Opisthoproctus soleatus) were found to have the best lenses, which may allow them to break the counterillumination camouflage of their prey. The heteropod lens had unidirectional aberrations that matched its ribbon-shaped retina. We also found that lens angular resolution increased with depth. Due to a similar trend in the angular separation between adjacent ganglion cells in the retinas of fishes, the perceived visual contrast at the retinal cutoff frequency was constant with depth. The increase in acuity with depth allows the predators to focus all the available light bioluminescent prey animals emit and detect their next meal. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Characteristic sounds facilitate visual search.

    Science.gov (United States)

    Iordanescu, Lucica; Guzman-Martinez, Emmanuel; Grabowecky, Marcia; Suzuki, Satoru

    2008-06-01

    In a natural environment, objects that we look for often make characteristic sounds. A hiding cat may meow, or the keys in the cluttered drawer may jingle when moved. Using a visual search paradigm, we demonstrated that characteristic sounds facilitated visual localization of objects, even when the sounds carried no location information. For example, finding a cat was faster when participants heard a meow sound. In contrast, sounds had no effect when participants searched for names rather than pictures of objects. For example, hearing "meow" did not facilitate localization of the word cat. These results suggest that characteristic sounds cross-modally enhance visual (rather than conceptual) processing of the corresponding objects. Our behavioral demonstration of object-based cross-modal enhancement complements the extensive literature on space-based cross-modal interactions. When looking for your keys next time, you might want to play jingling sounds.

  5. Artificial Intelligence Can Predict Daily Trauma Volume and Average Acuity.

    Science.gov (United States)

    Stonko, David P; Dennis, Bradley M; Betzold, Richard D; Peetz, Allan B; Gunter, Oliver L; Guillamondegui, Oscar D

    2018-04-19

    The goal of this study was to integrate temporal and weather data in order to create an artificial neural network (ANN) to predict trauma volume, the number of emergent operative cases, and average daily acuity at a level 1 trauma center. Trauma admission data from TRACS and weather data from the National Oceanic and Atmospheric Administration (NOAA) was collected for all adult trauma patients from July 2013-June 2016. The ANN was constructed using temporal (time, day of week), and weather factors (daily high, active precipitation) to predict four points of daily trauma activity: number of traumas, number of penetrating traumas, average ISS, and number of immediate OR cases per day. We trained a two-layer feed-forward network with 10 sigmoid hidden neurons via the Levenberg-Marquardt backpropagation algorithm, and performed k-fold cross validation and accuracy calculations on 100 randomly generated partitions. 10,612 patients over 1,096 days were identified. The ANN accurately predicted the daily trauma distribution in terms of number of traumas, number of penetrating traumas, number of OR cases, and average daily ISS (combined training correlation coefficient r = 0.9018+/-0.002; validation r = 0.8899+/- 0.005; testing r = 0.8940+/-0.006). We were able to successfully predict trauma and emergent operative volume, and acuity using an ANN by integrating local weather and trauma admission data from a level 1 center. As an example, for June 30, 2016, it predicted 9.93 traumas (actual: 10), and a mean ISS score of 15.99 (actual: 13.12); see figure 3. This may prove useful for predicting trauma needs across the system and hospital administration when allocating limited resources. Level III STUDY TYPE: Prognostic/Epidemiological.

  6. Unsound Sound

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    2016-01-01

    This article discusses the change in premise that digitally produced sound brings about and how digital technologies more generally have changed our relationship to the musical artifact, not simply in degree but in kind. It demonstrates how our acoustical conceptions are thoroughly challenged...... by the digital production of sound and, by questioning the ontological basis for digital sound, turns our understanding of the core term substance upside down....

  7. Sound Absorbers

    Science.gov (United States)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  8. Whose Line Sound is it Anyway? Identifying the Vocalizer on Underwater Video by Localizing with a Hydrophone Array

    Directory of Open Access Journals (Sweden)

    Matthias Hoffmann-Kuhnt

    2016-11-01

    Full Text Available A new device that combined high-resolution (1080p wide-angle video and three channels of high-frequency acoustic recordings (at 500 kHz per channel in a portable underwater housing was designed and tested with wild bottlenose and spotted dolphins in the Bahamas. It consisted of three hydrophones, a GoPro camera, a small Fit PC, a set of custom preamplifiers and a high-frequency data acquisition board. Recordings were obtained to identify individual vocalizing animals through time-delay-of-arrival localizing in post-processing. The calculated source positions were then overlaid onto the video – providing the ability to identify the vocalizing animal on the recorded video. The new tool allowed for much clearer analysis of the acoustic behavior of cetaceans than was possible before.

  9. Empiric determination of corrected visual acuity standards for train crews.

    Science.gov (United States)

    Schwartz, Steven H; Swanson, William H

    2005-08-01

    Probably the most common visual standard for employment in the transportation industry is best-corrected, high-contrast visual acuity. Because such standards were often established absent empiric linkage to job performance, it is possible that a job applicant or employee who has visual acuity less than the standard may be able to satisfactorily perform the required job activities. For the transportation system that we examined, the train crew is required to inspect visually the length of the train before and during the time it leaves the station. The purpose of the inspection is to determine if an individual is in a hazardous position with respect to the train. In this article, we determine the extent to which high-contrast visual acuity can predict performance on a simulated task. Performance at discriminating hazardous from safe conditions, as depicted in projected photographic slides, was determined as a function of visual acuity. For different levels of visual acuity, which was varied through the use of optical defocus, a subject was required to label scenes as hazardous or safe. Task performance was highly correlated with visual acuity as measured under conditions normally used for vision screenings (high-illumination and high-contrast): as the acuity decreases, performance at discriminating hazardous from safe scenes worsens. This empirically based methodology can be used to establish a corrected high-contrast visual acuity standard for safety-sensitive work in transportation that is linked to the performance of a job-critical task.

  10. 21 CFR 886.1150 - Visual acuity chart.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual acuity chart. 886.1150 Section 886.1150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1150 Visual acuity chart. (a) Identification...

  11. Gender and environmental influences on visual acuity in Owerri ...

    African Journals Online (AJOL)

    This study assessed the gender and environmental influences on visual function among adults in Owerri, Nigeria. Visual acuity (V.A.) is a measure of visual function in health and disease. Visual disability together with other disabling conditions is a barrier to development, yet there is little known about the visual acuity and ...

  12. Visual Acuity in Primary School Pupils in Lagos, Nigeria | Okoro ...

    African Journals Online (AJOL)

    ... in visual acuity. Conclusion: Eye defects occur among school children with potential negative effects. Pre-school entry eye examinations and regular screening is advocated and glasses should be made available for children with refractive error. Keywords: Visual Acuity, Screening, School Children, School Health ...

  13. Grating-acuity in children. Normal values of visual acuity in children up to 13 years as assessed by the acuity card procedure.

    Science.gov (United States)

    Schenk-Rootlieb, A J; van Nieuwenhuizen, O; van Zoggel, J; van der Graaf, Y; Willemse, J

    1992-09-01

    The acuity card procedure proved to be a useful method for assessing visual acuity in children. Normal values of visual acuity measured by this method had already been assessed in children up to four years. To enable application of the test in older children this study obtained values in a group of 396 normal children, aged three months to 13 years. The mean curve as well as the 10th centile was calculated in different age groups. A considerable variation of acuity values causing a 'dip' in the 10th centile was found in the ages 18 to 24 months. A smaller 'dip' was found in the ages 48 to 52 months. This has to be attributed to behavioural properties connected with age. The results obtained in the group of children under four years of age corresponded fairly well with other studies. In schoolchildren a fair agreement could also be found between the data obtained using the acuity card procedure and the data obtained with the Landolt-C rings. Obtaining normal values for the acuity card procedure in children covering a wide age range facilitates recognition of visual handicap in children who are difficult to assess.

  14. The association between higher education and approximate number system acuity

    Science.gov (United States)

    Lindskog, Marcus; Winman, Anders; Juslin, Peter

    2014-01-01

    Humans are equipped with an approximate number system (ANS) supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity) and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities), measured either early (First year) or late (Third year) in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity. PMID:24904478

  15. The association between higher education and approximate number system acuity.

    Science.gov (United States)

    Lindskog, Marcus; Winman, Anders; Juslin, Peter

    2014-01-01

    Humans are equipped with an approximate number system (ANS) supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity) and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities), measured either early (First year) or late (Third year) in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity.

  16. The Association Between Higher Education and Approximate Number System Acuity

    Directory of Open Access Journals (Sweden)

    Marcus eLindskog

    2014-05-01

    Full Text Available Humans are equipped with an Approximate Number System (ANS supporting non-symbolic numerosity representation. Studies indicate a relationship between ANS-precision (acuity and math achievement. Whether the ANS is a prerequisite for learning mathematics or if mathematics education enhances the ANS remains an open question. We investigated the association between higher education and ANS acuity with university students majoring in subjects with varying amounts of mathematics (mathematics, business, and humanities, measured either early (1th year or late (3rd year in their studies. The results suggested a non-significant trend where students taking more mathematics had better ANS acuity and a significant improvement in ANS acuity as a function of study length that was mainly confined to the business students. The results provide partial support for the hypothesis that education in mathematics can enhance the ANS acuity.

  17. Visual acuity and stereoacuity among mentally retarded children.

    Science.gov (United States)

    Letourneau, J E; Beaulne, C; Duplessis, L

    1992-12-01

    To evaluate the reliability and the validity of Landolt Rings and of the Frisby Test as measures of visual acuity and stereoacuity, respectively, the visual acuity of 30 mentally retarded children was measured with Landolt Rings shown as games, the Sjögren Test, the Dot Visual Acuity Test and stereoacuity with the Frisby Test. Subjects were tested 3 times over a period of 3 weeks to measure the reliability of the tests. No significant difference was observed among these tests. The validity of the Landolt Rings was measured by a correlation of .55 for the highest logMAR values of the Sjögren Test with the highest logMAR values of the Landolt Rings. Visual acuity was systematically lower on the Dot Visual Acuity Test. The Frisby Test was not reliable among a group of 16 normal children who improved systematically over 3 weeks.

  18. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2008-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  19. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2010-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  20. Sound generator

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2007-01-01

    A sound generator, particularly a loudspeaker, configured to emit sound, comprising a rigid element (2) enclosing a plurality of air compartments (3), wherein the rigid element (2) has a back side (B) comprising apertures (4), and a front side (F) that is closed, wherein the generator is provided

  1. Lawn mower injuries as a cause of serious visual acuity impairment - Case reports.

    Science.gov (United States)

    Jasielska, Monika; Winiarczyk, Mateusz; Bieliński, Paweł; Mackiewicz, Jerzy

    2017-05-11

    [b]Abstract Objective.[/b] The aim of the study is to present four cases of lawn mowers injuries as a cause of serious visual acuity impairment. [b]Materials and Method[/b]. A retrospective study of four patients admitted in 2013-2015 to the Department of Vitreoretinal Surgery in Lublin with severe open or closed globe injury, one with an intraocular foreign body (IOFB). The presence of eye protective equipment was assessed, as well as visual acuity, eye tissue condition before and after treatment, and applied therapy. In all cases an improvement was achieved in local conditions. The intraocular foreign body was removed, wounds sutured and damaged tissues placed in position. All eyeballs were saved. In three cases, visual acuity was improved to a usable level. Three patients underwent pars plana vitrectomy, one with IOFB removal from the vitreous cavity. [b]Conclusions[/b]. Lawn mower induced eye injuries are a significant cause of serious visual acuity impairment or blindness. The presented study shows that lawn mower eye injuries are still a therapeutic, social and economic problem, yet are very preventable with proper eye protection and patients' education. Current prevention strategies are inadequate, and therefore should be updated.

  2. Sound Zones

    DEFF Research Database (Denmark)

    Møller, Martin Bo; Olsen, Martin

    2017-01-01

    Sound zones, i.e. spatially confined regions of individual audio content, can be created by appropriate filtering of the desired audio signals reproduced by an array of loudspeakers. The challenge of designing filters for sound zones is twofold: First, the filtered responses should generate...... an acoustic separation between the control regions. Secondly, the pre- and post-ringing as well as spectral deterioration introduced by the filters should be minimized. The tradeoff between acoustic separation and filter ringing is the focus of this paper. A weighted L2-norm penalty is introduced in the sound...

  3. Sound intensity

    DEFF Research Database (Denmark)

    Crocker, Malcolm J.; Jacobsen, Finn

    1998-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  4. Sound Intensity

    DEFF Research Database (Denmark)

    Crocker, M.J.; Jacobsen, Finn

    1997-01-01

    This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique.......This chapter is an overview, intended for readers with no special knowledge about this particular topic. The chapter deals with all aspects of sound intensity and its measurement from the fundamental theoretical background to practical applications of the measurement technique....

  5. Localization of a sound source in in a guided medium and reverberating field. Contribution to a study on leak localization in the internal wall of containment of a nuclear reactor in the case of a severe reactor accident

    International Nuclear Information System (INIS)

    Thomann, F.

    1996-01-01

    Basic data necessary for the localization of a leak in the internal wall of the containment are presented by studying the sound generated by gas jets coming out of (leaking fissures) as well as propagation in a guided medium. The results acquired have led us to choose the simple intercorrelation method and the matched filed processing method, both of which are likely to adequately handle our problems. Whereas the intercorrelation method appears to be limited in scope when dealing in the guided medium, the matched field processing is suited to leak localization over a surface of approximately 1000 m 2 (for a total surface of 10 000 m 2 ). Preliminary studies on the leak signal and on replicated signals have led us to limit the frequency band to 2600 - 3000 Hz. We have succeeded in locating a leak situated in an ordinary position with a minimum amount of replicated signals and basic data. We have improved on the estimation of Bartlett and MVDE (minimum variance distortion less filter) rendering them even more effective. Afterwards, we considered the severe accident situation and showed that the system can be installed in situ. (author)

  6. Sound Localization in Multisource Environments

    Science.gov (United States)

    2009-03-01

    A total of 7 paid volunteer listeners (3 males and 4 females, 20-25 years of age ) par- ticipated in the experiment. All had normal hearing (i.e...effects of the loudspeaker frequency responses, and were then sent from an experimental control computer to a Mark of the Unicorn (MOTU 24 I/O) digital-to...after the overall multisource stimulus has been presented (the ’post-cue’ condition). 3.2 Methods 3.2.1 Listeners Eight listeners, ranging in age from

  7. The two sides of sensory-cognitive interactions: effects of age, hearing acuity, and working memory span on sentence comprehension

    Directory of Open Access Journals (Sweden)

    Renee eDeCaro

    2016-02-01

    Full Text Available Reduced hearing acuity is among the most prevalent of chronic medical conditions among older adults. An experiment is reported in which comprehension of spoken sentences was tested for older adults with good hearing acuity or with a mild-to-moderate hearing loss, and young adults with age-normal hearing. Comprehension was measured by participants’ ability to determine of the agent of an action in sentences that expressed this relation with a syntactically less complex subject-relative construction or a syntactically more complex object-relative construction. Agency determination was further challenged by inserting a prepositional phrase into sentences between the person performing an action and the action being performed. As a control, prepositional phrases of equivalent length were also inserted into sentences in a non-disruptive position. Effects on sentence comprehension of age, hearing acuity, prepositional phrase placement and sound level of stimulus presentations appeared only for comprehension of sentences with the more syntactically complex object-relative structures. Working memory as tested by reading span scores accounted for a significant amount of the variance in comprehension accuracy. Once working memory capacity and hearing acuity were taken into account, chronological age among the older adults contributed no further variance to comprehension accuracy. Results are discussed in terms of the positive and negative effects of sensory-cognitive interactions in comprehension of spoken sentences and lend support to a framework in which domain-general executive resources, notably verbal working memory, play a role in both linguistic and perceptual processing.

  8. Gender and environmental influences on visual acuity in Owerri ...

    African Journals Online (AJOL)

    olayemitoyin

    1Optometry Unit, Eye Clinic, Federal Medical Centre, Owerri, Imo State, 2Department of Physiology, College ... Visual acuity (V.A.) is a measure of visual function in health and disease. ..... environment especially during harmattan and dry.

  9. Modelling the training effects of kinaesthetic acuity measurement in children.

    Science.gov (United States)

    Sims, K; Morton, J

    1998-07-01

    In previous papers (Sims, Henderson, Hulme, & Morton, 1996a; Sims, Henderson, Morton, & Hulme, 1996b) we have found that the motor skills of clumsy children are capable of significant improvement following relatively brief interventions. Most remarkably, this included a 10-minute intervention while testing the kinaesthetic acuity of the children using a staircase method (Pest). In this paper, we show that Pest testing improves the kinaesthetic acuity of normal children as well. We analyse the available data on the development and improvement of motor skills and kinaesthetic acuity and derive a causal model for the underlying skills. We show that at least three independent cognitive/biological components are required to account for the data. These three components are affected differently by the various interventions that have been tried. We deduce that improvement on a general test of motor impairment can be found as a result of training in kinaesthetic acuity or through other, independent factors.

  10. RETENTION OF HIGH TACTILE ACUITY THROUGHOUT THE LIFESPAN IN BLINDNESS

    OpenAIRE

    Legge, Gordon E.; Madison, Cindee; Vaughn, Brenna N.; Cheong, Allen M.Y.; Miller, Joseph C.

    2008-01-01

    Previous studies of tactile acuity on the fingertip using passive touch have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have re-examined this age dependence with two newly designed tactile-acuity charts requiring active exploration of the test symbols. One chart used dot patterns similar to Braille and the other used embossed Landolt rings. Groups of blind Braille readers and sighted subjects, ranging in age from 12 to 85 years, were test...

  11. Fluid Sounds

    DEFF Research Database (Denmark)

    Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects and in arch......Explorations and analysis of soundscapes have, since Canadian R. Murray Schafer's work during the early 1970's, developed into various established research - and artistic disciplines. The interest in sonic environments is today present within a broad range of contemporary art projects...... and in architectural design. Aesthetics, psychoacoustics, perception, and cognition are all present in this expanding field embracing such categories as soundscape composition, sound art, sonic art, sound design, sound studies and auditory culture. Of greatest significance to the overall field is the investigation...

  12. Seeing 'where' through the ears: effects of learning-by-doing and long-term sensory deprivation on localization based on image-to-sound substitution.

    Directory of Open Access Journals (Sweden)

    Michael J Proulx

    Full Text Available BACKGROUND: Sensory substitution devices for the blind translate inaccessible visual information into a format that intact sensory pathways can process. We here tested image-to-sound conversion-based localization of visual stimuli (LEDs and objects in 13 blindfolded participants. METHODS AND FINDINGS: Subjects were assigned to different roles as a function of two variables: visual deprivation (blindfolded continuously (Bc for 24 hours per day for 21 days; blindfolded for the tests only (Bt and system use (system not used (Sn; system used for tests only (St; system used continuously for 21 days (Sc. The effect of learning-by-doing was assessed by comparing the performance of eight subjects (BtSt who only used the mobile substitution device for the tests, to that of three subjects who, in addition, practiced with it for four hours daily in their normal life (BtSc and BcSc; two subjects who did not use the device at all (BtSn and BcSn allowed assessment of its use in the tasks we employed. The impact of long-term sensory deprivation was investigated by blindfolding three of those participants throughout the three week-long experiment (BcSn, BcSn/c, and BcSc; the other ten subjects were only blindfolded during the tests (BtSn, BtSc, and the eight BtSt subjects. Expectedly, the two subjects who never used the substitution device, while fast in finding the targets, had chance accuracy, whereas subjects who used the device were markedly slower, but showed much better accuracy which improved significantly across our four testing sessions. The three subjects who freely used the device daily as well as during tests were faster and more accurate than those who used it during tests only; however, long-term blindfolding did not notably influence performance. CONCLUSIONS: Together, the results demonstrate that the device allowed blindfolded subjects to increasingly know where something was by listening, and indicate that practice in naturalistic conditions

  13. Sound Settlements

    DEFF Research Database (Denmark)

    Mortensen, Peder Duelund; Hornyanszky, Elisabeth Dalholm; Larsen, Jacob Norvig

    2013-01-01

    Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice......Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice...

  14. Nuclear sound

    International Nuclear Information System (INIS)

    Wambach, J.

    1991-01-01

    Nuclei, like more familiar mechanical systems, undergo simple vibrational motion. Among these vibrations, sound modes are of particular interest since they reveal important information on the effective interactions among the constituents and, through extrapolation, on the bulk behaviour of nuclear and neutron matter. Sound wave propagation in nuclei shows strong quantum effects familiar from other quantum systems. Microscopic theory suggests that the restoring forces are caused by the complex structure of the many-Fermion wavefunction and, in some cases, have no classical analogue. The damping of the vibrational amplitude is strongly influenced by phase coherence among the particles participating in the motion. (author)

  15. An Acuity Tool for Heart Failure Case Management: Quantifying Workload, Service Utilization, and Disease Severity.

    Science.gov (United States)

    Kilgore, Matthew D

    and practice application of the KHFCM Acuity Tool. Quality improvement outcomes included a more valid reflection of encounter times and demonstration of the KHFCM Acuity Tool as a reliable, practical, credible, and satisfying tool for reflecting HF case manager workloads and HF disease severity. The KHFCM Acuity Tool defines workload simply as a function of the number of HFCM services performed and the duration of time spent on a client encounter. The design of the tool facilitates the measure of workload, service utilization, and HF disease characteristics, independently from the overall measure of acuity, so that differences in individual case manager practice, as well as client characteristics within sites, across sites, and potentially throughout annual seasons, can be demonstrated. Data produced from long-term applications of the KHFCM Acuity Tool, across all regions, could serve as a driver for establishing systemwide HFCM productivity benchmarks or standards of practice for HF case managers. Data produced from localized applications could serve as a reference for coordinating staffing resources or developing HFCM productivity benchmarks within individual regions or sites.

  16. Sound Settlements

    DEFF Research Database (Denmark)

    Mortensen, Peder Duelund; Hornyanszky, Elisabeth Dalholm; Larsen, Jacob Norvig

    2013-01-01

    Præsentation af projektresultater fra Interreg forskningen Sound Settlements om udvikling af bæredygtighed i det almene boligbyggerier i København, Malmø, Helsingborg og Lund samt europæiske eksempler på best practice...

  17. Second Sound

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 4; Issue 6. Second Sound - The Role of Elastic Waves. R Srinivasan. General Article Volume 4 Issue 6 June 1999 pp 15-19. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/004/06/0015-0019 ...

  18. Relationships between luminance and visual acuity in the rhesus monkey

    Science.gov (United States)

    Cavonius, C. R.; Robbins, D. O.

    1973-01-01

    1. The ability of rhesus monkeys to detect the gap in Landolt ring test-objects that were presented against background luminances between 5 × 10-5 cd/m2 and 5 × 103 cd/m2 was compared with similar human data. 2. At high luminance-levels the acuity of human observers is slightly better than that of rhesus, but rhesus have better acuity at scotopic luminance-levels. Both species have distinct photopic and scotopic acuity functions that cross at 6 × 10-3 cd/m2. 3. The threshold for light detection is estimated to be the same for both species when specified in quanta incident on the retina. 4. It is concluded that the receptor and neural mechanisms that mediate visual-acuity function similarly in rhesus and man, and that the differences in acuity that were measured in the two species may be attributed to optical rather than to physiological factors. PMID:4199366

  19. A case-control study of visual acuity in onychocryptosis.

    LENUS (Irish Health Repository)

    Hogan, Aisling M

    2012-02-01

    BACKGROUND: There are many theories surrounding the etiology of ingrown toenails (IGTN). Few factors have been formally assessed, but it is widely accepted that a poor nail cutting technique has a causative role. AIM: To investigate the hypothesis that decreased visual acuity may lead to inadequate nail cutting and the formation of IGTN. METHODS: A prospective case-control study was performed. Near and distance visual acuity were tested on a population with IGTN (n = 19) and compared with that of an age- and sex-matched control cohort (n = 24) who underwent epidermal cyst excision in the same tertiary referral center. Comparisons of visual acuity were made between groups by Mann-Whitney U-test. Differences were taken to be significant if P < 0.05. Institutional Review Board approval was sought and granted. RESULTS: No significant difference in visual acuity (near or distance) was demonstrated between patients with IGTN and the control group (P = 0.33). CONCLUSION: Visual acuity does not appear to play a significant role in the development of IGTN.

  20. [Evaluation of visual acuity in a historical cohort of 137 patients treated for amblyopia by occlusion 30-35 years ago].

    Science.gov (United States)

    Simonsz-Tóth, B; Loudon, S E; van Kempen-du Saar, H; van de Graaf, E S; Groenewoud, J H; Simonsz, H J

    2007-01-01

    Opinions differ on the course of the visual acuity in the amblyopic eye after cessation of occlusion therapy. This study evaluated visual acuity in a historical cohort treated for amblyopia with occlusion therapy 30-35 years ago. Between 1968 and 1975, 1250 patients had been treated by the orthoptist in the Waterland Hospital in Purmerend, The Netherlands. Of these, 471 received occlusion treatment for amblyopia (prevalence 5.0%, after comparison with the local birth rate). We were able to contact 203 of these patients, 137 were orthoptically re-examined in 2003. We correlated the current visual acuity with the cause of amblyopia, the age at start and end of treatment, the visual acuity at start and end of treatment, fixation, binocular vision and refractive errors. Mean age at the start of treatment was 5.4 +/- 1.9 years, 7.4 +/- 1.7 years at the end and 37 +/- 2.7 years at follow-up. Current visual acuity in the amblyopic eye was correlated with a low visual acuity at the start (p occlusion therapy, an eccentric fixation (p amblyopia (p = 0.005). At the end of the treatment, patients with a strabismic amblyopia (n = 98) had a visual acuity in the amblyopic eye of 0.29 logMAR +/- 0.3, and in 2003 0.27 +/- 0.3 logMAR. In patients with an anisometropic amblyopia (> 1 D, n = 16) visual acuity had decreased from 0.17 +/- 0.23 logMAR to 0.21 logMAR +/- 0.23. In patients with both strabismic and anisometropic amblyopia (n = 23), visual acuity had decreased from 0.52 logMAR +/- 0.54 to 0.65 logMAR +/- 0.54. Overall, acuity had decreased in 54 patients (39%) after cessation of treatment. Of these, 18 patients had an acuity decrease to less than 50% of their acuity at the end of treatment. In 15 of these 18 patients anisohypermetropia had increased. A decrease in visual acuity after cessation of occlusion therapy occurred in patients with a combined cause of amblyopia or with an increase in anisohypermetropia.

  1. PREFACE: Aerodynamic sound Aerodynamic sound

    Science.gov (United States)

    Akishita, Sadao

    2010-02-01

    The modern theory of aerodynamic sound originates from Lighthill's two papers in 1952 and 1954, as is well known. I have heard that Lighthill was motivated in writing the papers by the jet-noise emitted by the newly commercialized jet-engined airplanes at that time. The technology of aerodynamic sound is destined for environmental problems. Therefore the theory should always be applied to newly emerged public nuisances. This issue of Fluid Dynamics Research (FDR) reflects problems of environmental sound in present Japanese technology. The Japanese community studying aerodynamic sound has held an annual symposium since 29 years ago when the late Professor S Kotake and Professor S Kaji of Teikyo University organized the symposium. Most of the Japanese authors in this issue are members of the annual symposium. I should note the contribution of the two professors cited above in establishing the Japanese community of aerodynamic sound research. It is my pleasure to present the publication in this issue of ten papers discussed at the annual symposium. I would like to express many thanks to the Editorial Board of FDR for giving us the chance to contribute these papers. We have a review paper by T Suzuki on the study of jet noise, which continues to be important nowadays, and is expected to reform the theoretical model of generating mechanisms. Professor M S Howe and R S McGowan contribute an analytical paper, a valuable study in today's fluid dynamics research. They apply hydrodynamics to solve the compressible flow generated in the vocal cords of the human body. Experimental study continues to be the main methodology in aerodynamic sound, and it is expected to explore new horizons. H Fujita's study on the Aeolian tone provides a new viewpoint on major, longstanding sound problems. The paper by M Nishimura and T Goto on textile fabrics describes new technology for the effective reduction of bluff-body noise. The paper by T Sueki et al also reports new technology for the

  2. Improved Mental Acuity Forecasting with an Individualized Quantitative Sleep Model

    Directory of Open Access Journals (Sweden)

    Brent D. Winslow

    2017-04-01

    Full Text Available Sleep impairment significantly alters human brain structure and cognitive function, but available evidence suggests that adults in developed nations are sleeping less. A growing body of research has sought to use sleep to forecast cognitive performance by modeling the relationship between the two, but has generally focused on vigilance rather than other cognitive constructs affected by sleep, such as reaction time, executive function, and working memory. Previous modeling efforts have also utilized subjective, self-reported sleep durations and were restricted to laboratory environments. In the current effort, we addressed these limitations by employing wearable systems and mobile applications to gather objective sleep information, assess multi-construct cognitive performance, and model/predict changes to mental acuity. Thirty participants were recruited for participation in the study, which lasted 1 week. Using the Fitbit Charge HR and a mobile version of the automated neuropsychological assessment metric called CogGauge, we gathered a series of features and utilized the unified model of performance to predict mental acuity based on sleep records. Our results suggest that individuals poorly rate their sleep duration, supporting the need for objective sleep metrics to model circadian changes to mental acuity. Participant compliance in using the wearable throughout the week and responding to the CogGauge assessments was 80%. Specific biases were identified in temporal metrics across mobile devices and operating systems and were excluded from the mental acuity metric development. Individualized prediction of mental acuity consistently outperformed group modeling. This effort indicates the feasibility of creating an individualized, mobile assessment and prediction of mental acuity, compatible with the majority of current mobile devices.

  3. VEP-based acuity assessment in low vision.

    Science.gov (United States)

    Hoffmann, Michael B; Brands, Jan; Behrens-Baumann, Wolfgang; Bach, Michael

    2017-12-01

    Objective assessment of visual acuity (VA) is possible with VEP methodology, but established with sufficient precision only for vision better than about 1.0 logMAR. We here explore whether this can be extended down to 2.0 logMAR, highly desirable for low-vision evaluations. Based on the stepwise sweep algorithm (Bach et al. in Br J Ophthalmol 92:396-403, 2008) VEPs to monocular steady-state brief onset pattern stimulation (7.5-Hz checkerboards, 40% contrast, 40 ms on, 93 ms off) were recorded for eight different check sizes, from 0.5° to 9.0°, for two runs with three occipital electrodes in a Laplace-approximating montage. We examined 22 visually normal participants where acuity was reduced to ≈ 2.0 logMAR with frosted transparencies. With the established heuristic algorithm the "VEP acuity" was extracted and compared to psychophysical VA, both obtained at 57 cm distance. In 20 of the 22 participants with artificially reduced acuity the automatic analysis indicated a valid result (1.80 logMAR on average) in at least one of the two runs. 95% test-retest limits of agreement on average were ± 0.09 logMAR for psychophysical, and ± 0.21 logMAR for VEP-derived acuity. For 15 participants we obtained results in both runs and averaged them. In 12 of these 15 the low-acuity results stayed within the 95% confidence interval (± 0.3 logMAR) as established by Bach et al. (2008). The fully automated analysis yielded good agreement of psychophysical and electrophysiological VAs in 12 of 15 cases (80%) in the low-vision range down to 2.0 logMAR. This encourages us to further pursue this methodology and assess its value in patients.

  4. Sound Visualisation

    OpenAIRE

    Dolenc, Peter

    2013-01-01

    This thesis contains a description of a construction of subwoofer case that has an extra functionality of being able to produce special visual effects and display visualizations that match the currently playing sound. For this reason, multiple lighting elements made out of LED (Light Emitting Diode) diodes were installed onto the subwoofer case. The lighting elements are controlled by dedicated software that was also developed. The software runs on STM32F4-Discovery evaluation board inside a ...

  5. [Determining visual acuity with LH symbols and Landolt rings].

    Science.gov (United States)

    Gräf, M; Becker, R

    1999-08-01

    Lea (LH) symbols seem to be favourable for visual acuity assessment in childhood. The symbols of the LH test are well standardized and applicable to preschool children. We compared the visual acuity determined by LH single symbols (LH) and the acuity measured with the Landolt-C (LC). 138 cooperative subjects aged 7 to 91 years were examined. Their visual acuity was either normal or reduced due to various etiologies. Their refractive error was corrected. The monocular LH and LC were determined by a 3/4 criterion (study 1). In 19 healthy subjects aged 21 to 58 years, acuity was reduced stepwise by 5 different calibrated occlusives (study 2). A Lighthouse single symbol book (LH symbols) was used at a distance of 3 m. LC was determined at a distance of 5 m. The luminance of the test field was 180-200 cd/m2. The right eye of each patient and the amblyopic eye of the squinting patients was taken for statistical evaluation. The strabismic patients' interocular differences of LC and LH were compared. Within study 1, LC ranged from 0.02 to 2.0 and LH from 0.03 to 2.5. LH overestimated LC by 1.4 lines on an average (t-test p 1 line, 85.7% resp. 90% of the strabismic amblyopic patients with an interocular LC difference > 1 resp > 2 lines were detected. In study 2, LC ranged from 0.1 to 1.6, LH from 0.12 to 2.0. The mean difference LH-LC was 1.3 lines. The regression equation was lgLH = 0.91 lgLC + 0.08 (r = 0.95). LH symbols allow a reliable measurement of recognition acuity. Due to the design of the symbols, they are excellently suitable for application to preschool children. Age related normal values should be established. The systematic difference between the LC acuity and the LH acuity measured with the Lighthouse LH single symbol book by 1.4 lines has to be considered.

  6. Socio-Demographic Factors Associated With Loss Of Visual Acuity ...

    African Journals Online (AJOL)

    The study was designed to identify the sociodemographic factors, which significantly affect the visual acuity of glaucoma patients at presentation. It is a prospective study of 154 new patients with a diagnosis of primary open angle glaucoma seen over 1 year and 8 months at the eye clinic of the University of Benin Teaching ...

  7. Visual acuity outcomes in eyes with flat corneas after PRK.

    Science.gov (United States)

    Varssano, David; Waisbourd, Michael; Minkev, Liza; Sela, Tzahi; Neudorfer, Meira; Binder, Perry S

    2013-06-01

    To evaluate the impact of corneal curvatures less than 35 diopters (D) after photorefractive keratectomy (PRK) on visual acuity outcomes. Visual acuity outcomes of 5,410 eyes that underwent PRK from January 2006 to November 2010 were retrospectively analyzed for the impact of postoperative corneal curvatures on visual outcomes. All procedures were performed on a single platform (Allegretto 200Hz excimer laser; Alcon Laboratories, Inc., Irvine, CA). Main outcome measures were postoperative corrected distance visual acuity (CDVA) and loss of CDVA. Corneas with a measured or a calculated postoperative flat meridian less than 35 D and those with a measured postoperative steep meridian less than 35 D had worse postoperative CDVA than corneas with meridians of either 35 D or more (P ≤ .021). However, the preoperative CDVA was worse in the flatter curvatures in all comparisons performed (P ≤ .024). Consequently, the measured or calculated meridian curvature had no effect on CDVA loss (P ≥ .074). Postoperative corneal keratometry values (flat and steep meridians) less than 35 D did not have a predictive effect on the risk of losing visual acuity following myopic PRK performed on the Allegretto 200Hz excimer laser. Copyright 2013, SLACK Incorporated.

  8. Arithmetic Training Does Not Improve Approximate Number System Acuity

    Directory of Open Access Journals (Sweden)

    Marcus Lindskog

    2016-10-01

    Full Text Available The Approximate Number System (ANS is thought to support non-symbolic representations of numerical magnitudes in humans. Recently much debate has focused on the causal direction for an observed relation between ANS acuity and arithmetic fluency. Here we investigate if arithmetic training can improve ANS acuity. We show with an experimental training study consisting of six 45-minute training sessions that although feedback during arithmetic training improves arithmetic performance substantially, it does not influence ANS acuity. Hence, we find no support for a causal link where symbolic arithmetic training influences the ANS acuity. Further, although short-term number memory is likely involved in arithmetic tasks we did not find that short-term memory capacity for numbers, measured by a digit-span test, was effected by arithmetic training. This suggests that the improvement in arithmetic fluency may have occurred independent of short-term memory efficiency, but rather due to long-term memory processes and/or mental calculation strategy development. The theoretical implications of these findings are discussed.

  9. P3-4: Binocular Visual Acuity in Exotropia

    Directory of Open Access Journals (Sweden)

    Heekyung Yang

    2012-10-01

    Full Text Available Purpose: To investigate binocular interaction of visual acuity in patients with intermittent exotropia and its relationship with accommodative responses during binocular vision. Methods: Sixty-seven patients with intermittent exotropia of 8 years or older were included. Binocular visual acuity (BVA and monocular visual acuity (MVA were measured in sequence. Accommodative responses of both eyes were measured using the WAM-5500 autorefractor/keratometer (GrandSeiko, Fukuyama, Japan during binocular and monocular viewing conditions at 6 m. Accommodative responses during binocular vision were calculated using the difference between the refractive errors of binocular and monocular vision. Main outcome measures: Binocular interactions of visual acuity were categorized as binocular summation, equivalency, or inhibition. The prevalence of the 3 patterns of binocular interaction was investigated. Accommodative responses were correlated with differences between BVA and better MVA. Results: Most patients (41 patients, 61.2% showed binocular equivalency. Binocular inhibition and summation were noted in 6 (9.0% and 20 (29.9% patients, respectively. Linear regression analysis revealed a significant correlation between binocular interaction and accommodative responses during binocular vision (p < .001. Accommodative responses significantly correlated with the angle of exodeviation at distance (p = .002. Conclusions: In patients with intermittent exotropia, binocular inhibition is associated with increased accommodation and a larger angle of exodeviation, suggesting that accommodative convergence is a mechanism that maintains ocular alignment. Thus, BVA inhibition may be attributed to diminishing fusional control in patients with intermittent exotropia.

  10. Astronauts Cooper and Conrad prepare cameras during visual acuity tests

    Science.gov (United States)

    1965-01-01

    Astronauts L. Gordon Cooper Jr. (left), command pilot, and Charles Conrad Jr., pilot, the prime crew of the Gemini 5 space flight, prepare their cameras while aboard a C-130 aircraft flying near Laredo. The two astronauts are taking part in a series of visual acuity experiments to aid them in learning to identify known terrestrial features under controlled conditions.

  11. Visual acuity and visual field impairment in Usher syndrome.

    Science.gov (United States)

    Edwards, A; Fishman, G A; Anderson, R J; Grover, S; Derlacki, D J

    1998-02-01

    To determine the extent of visual acuity and visual field impairment in patients with types 1 and 2 Usher syndrome. The records of 53 patients with type 1 and 120 patients with type 2 Usher syndrome were reviewed for visual acuity and visual field area at their most recent visit. Visual field areas were determined by planimetry of the II4e and V4e isopters obtained with a Goldmann perimeter. Both ordinary and logistic regression models were used to evaluate differences in visual acuity and visual field impairment between patients with type 1 and type 2 Usher syndrome. The difference in visual acuity of the better eye between patients with type 1 and type 2 varied by patient age (P=.01, based on a multiple regression model). The maximum difference in visual acuity between the 2 groups occurred during the third and fourth decades of life (with the type 1 patients being more impaired), while more similar acuities were seen in both younger and older patients. Fifty-one percent (n=27) of the type 1 patients had a visual acuity of 20/40 or better in at least 1 eye compared with 72% (n=87) of the type 2 patients (age-adjusted odds ratio, 3.9). Visual field area to both the II4e (P=.001) and V4e (Ptype 1 patients than type 2 patients. A concentric central visual field greater than 20 degrees in at least 1 eye was present in 20 (59%) of the available 34 visual fields of type 1 patients compared with 70 (67%) of the available 104 visual fields of type 2 patients (age-adjusted odds ratio, 2.9) with the V4e target and in 6 (21%) of the available 29 visual fields of type 1 patients compared with 36 (38%) of the available 94 visual fields of type 2 patients (age-adjusted odds ratio, 4.9) with the II4e target. The fraction of patients who had a visual acuity of 20/40 or better and a concentric central visual field greater than 20 degrees to the II4e target in at least 1 eye was 17% (n=5) in the type 1 patients and 35% (n=33) in the type 2 patients (age-adjusted odds ratio, 3

  12. Desktop publishing and validation of custom near visual acuity charts.

    Science.gov (United States)

    Marran, Lynn; Liu, Lei; Lau, George

    2008-11-01

    Customized visual acuity (VA) assessment is an important part of basic and clinical vision research. Desktop computer based distance VA measurements have been utilized, and shown to be accurate and reliable, but computer based near VA measurements have not been attempted, mainly due to the limited spatial resolution of computer monitors. In this paper, we demonstrate how to use desktop publishing to create printed custom near VA charts. We created a set of six near VA charts in a logarithmic progression, 20/20 through 20/63, with multiple lines of the same acuity level, different letter arrangements in each line and a random noise background. This design allowed repeated measures of subjective accommodative amplitude without the potential artifact of familiarity of the optotypes. The background maintained a constant and spatial frequency rich peripheral stimulus for accommodation across the six different acuity levels. The paper describes in detail how pixel-wise accurate black and white bitmaps of Sloan optotypes were used to create the printed custom VA charts. At all acuity levels, the physical sizes of the printed custom optotypes deviated no more than 0.034 log units from that of the standard, satisfying the 0.05 log unit ISO criterion we used to demonstrate physical equivalence. Also, at all acuity levels, log unit differences in the mean target distance for which reliable recognition of letters first occurred for the printed custom optotypes compared to the standard were found to be below 0.05, satisfying the 0.05 log unit ISO criterion we used to demonstrate functional equivalence. It is possible to use desktop publishing to create custom near VA charts that are physically and functionally equivalent to standard VA charts produced by a commercial printing process.

  13. The high cost of low-acuity ICU outliers.

    Science.gov (United States)

    Dahl, Deborah; Wojtal, Greg G; Breslow, Michael J; Holl, Randy; Huguez, Debra; Stone, David; Korpi, Gloria

    2012-01-01

    Direct variable costs were determined on each hospital day for all patients with an intensive care unit (ICU) stay in four Phoenix-area hospital ICUs. Average daily direct variable cost in the four ICUs ranged from $1,436 to $1,759 and represented 69.4 percent and 45.7 percent of total hospital stay cost for medical and surgical patients, respectively. Daily ICU cost and length of stay (LOS) were higher in patients with higher ICU admission acuity of illness as measured by the APACHE risk prediction methodology; 16.2 percent of patients had an ICU stay in excess of six days, and these LOS outliers accounted for 56.7 percent of total ICU cost. While higher-acuity patients were more likely to be ICU LOS outliers, 11.1 percent of low-risk patients were outliers. The low-risk group included 69.4 percent of the ICU population and accounted for 47 percent of all LOS outliers. Low-risk LOS outliers accounted for 25.3 percent of ICU cost and incurred fivefold higher hospital stay costs and mortality rates. These data suggest that severity of illness is an important determinant of daily resource consumption and LOS, regardless of whether the patient arrives in the ICU with high acuity or develops complications that increase acuity. The finding that a substantial number of long-stay patients come into the ICU with low acuity and deteriorate after ICU admission is not widely recognized and represents an important opportunity to improve patient outcomes and lower costs. ICUs should consider adding low-risk LOS data to their quality and financial performance reports.

  14. The Dual-channel Extreme Ultraviolet Continuum Experiment: Sounding Rocket EUV Observations of Local B Stars to Determine Their Potential for Supplying Intergalactic Ionizing Radiation

    Science.gov (United States)

    Erickson, Nicholas; Green, James C.; France, Kevin; Stocke, John T.; Nell, Nicholas

    2018-06-01

    We describe the scientific motivation and technical development of the Dual-channel Extreme Ultraviolet Continuum Experiment (DEUCE). DEUCE is a sounding rocket payload designed to obtain the first flux-calibrated spectra of two nearby B stars in the EUV 650-1150Å bandpass. This measurement will help in understanding the ionizing flux output of hot B stars, calibrating stellar models and commenting on the potential contribution of such stars to reionization. DEUCE consists of a grazing incidence Wolter II telescope, a normal incidence holographic grating, and the largest (8” x 8”) microchannel plate detector ever flown in space, covering the 650-1150Å band in medium and low resolution channels. DEUCE will launch on December 1, 2018 as NASA/CU sounding rocket mission 36.331 UG, observing Epsilon Canis Majoris, a B2 II star.

  15. Sounds of Space

    Science.gov (United States)

    Gurnett, D. A.

    2005-12-01

    Starting in the early 1960s, spacecraft-borne plasma wave instruments revealed that space is filled with an astonishing variety of radio and plasma wave sounds, which have come to be called "sounds of space." For over forty years these sounds have been collected and played to a wide variety of audiences, often as the result of press conferences or press releases involving various NASA projects for which the University of Iowa has provided plasma wave instruments. This activity has led to many interviews on local and national radio programs, and occasionally on programs haviang world-wide coverage, such as the BBC. As a result of this media coverage, we have been approached many times by composers requesting copies of our space sounds for use in their various projects, many of which involve electronic synthesis of music. One of these collaborations led to "Sun Rings," which is a musical event produced by the Kronos Quartet that has played to large audiences all over the world. With the availability of modern computer graphic techniques we have recently been attempting to integrate some of these sound of space into an educational audio/video web site that illustrates the scientific principles involved in the origin of space plasma waves. Typically I try to emphasize that a substantial gas pressure exists everywhere in space in the form of an ionized gas called a plasma, and that this plasma can lead to a wide variety of wave phenomenon. Examples of some of this audio/video material will be presented.

  16. Otite média recorrente e habilidade de localização sonora em pré-escolares Otitis media and sound localization ability in preschool children

    Directory of Open Access Journals (Sweden)

    Aveliny Mantovan Lima-Gregio

    2010-12-01

    Full Text Available OBJETIVO: comparar o desempenho de 40 pré-escolares no teste de localização sonora com as respostas de seus pais para um questionário que investigou a ocorrência de episódios de otite média (OM e os sintomas indicativos de desordens audiológicas e do processamento auditivo. MÉTODOS: após aplicação e análise das respostas do questionário, dois grupos foram formados: GO, com histórico de OM, e GC, sem este histórico. Cada grupo com 20 pré-escolares de ambos os gêneros foi submetido ao teste de localização da fonte sonora em cinco direções (Pereira, 1993. RESULTADOS: a comparação entre GO e GC não mostrou diferença estatisticamente significante (p=1,0000. CONCLUSÃO: as otites recorrentes na primeira infância não influenciaram no desempenho da habilidade de localização sonora dos pré-escolares deste estudo. Embora sejam dois instrumentos baratos e de fácil aplicação, o questionário e o teste de localização não foram suficientes para diferenciar os dois grupos testados.PURPOSE: to compare the sound localization ability of 40 preschool children with their parents' answers. The questionnaire answered by the parents investigated otitis media (OM episodes and symptoms that indicated the audiological and auditory processing disabilities. METHODS: after applying and analyzing the questionnaire's answers, two groups were formed: OG (with OM and CG (control group. Each group with 20 preschool children, of both genders, was submitted to the sound localization test in five directions (according to Pereira, 1993. RESULTS: comparison between OG and CG did not reveal statistically significant difference (p=1.0000. CONCLUSION: OM episodes during first infancy did not influence the sound localization ability in this preschool children study. Although both used evaluation instruments (questionnaire and sound localization test are cheap and easy to apply they are not sufficient to differ both tested groups.

  17. Contributing factors to VEP grating acuity deficit and inter-ocular acuity difference in children with cerebral visual impairment.

    Science.gov (United States)

    Cavascan, Nívea Nunes; Salomão, Solange Rios; Sacai, Paula Yuri; Pereira, Josenilson Martins; Rocha, Daniel Martins; Berezovsky, Adriana

    2014-04-01

    To investigate contributing factors to visual evoked potential (VEP) grating acuity deficit (GAD) and inter-ocular acuity difference (IAD) measured by sweep-VEPs in children with cerebral visual impairment (CVI). VEP GAD was calculated for the better acuity eye by subtracting acuity thresholds from mean normal VEP grating acuity according to norms from our own laboratory. Deficits were categorized as mild (0.17 ≤ deficit children (66 males-57 %) with ages ranging from 1.2 to 166.5 months (median = 17.7) was examined. VEP GAD ranged from 0.17 to 1.28 log units (mean = 0.68 ± 0.27; median = 0.71), and it was mild in 23 (20 %) children, moderate in 32 (28 %) and severe in 60 (52 %). Severe deficit was significantly associated with older age and anti-seizure drug therapy. IAD ranged from 0 to 0.49 log units (mean = 0.06 ± 0.08; median = 0.04) and was acceptable in 96 (83 %) children. Children with strabismus and nystagmus had IAD significantly larger compared to children with orthoposition. In a large cohort of children with CVI, variable severity of VEP GAD was found, with more than half of the children with severe deficits. Older children and those under anti-seizure therapy were at higher risk for larger deficits. Strabismus and nystagmus provided larger IADs. These results should be taken into account on the clinical management of children with this leading cause of bilateral visual impairment.

  18. local

    Directory of Open Access Journals (Sweden)

    Abílio Amiguinho

    2005-01-01

    Full Text Available The process of socio-educational territorialisation in rural contexts is the topic of this text. The theme corresponds to a challenge to address it having as main axis of discussion either the problem of social exclusion or that of local development. The reasons to locate the discussion in this last field of analysis are discussed in the first part of the text. Theoretical and political reasons are there articulated because the question is about projects whose intentions and practices call for the political both in the theoretical debate and in the choices that anticipate intervention. From research conducted for several years, I use contributions that aim at discuss and enlighten how school can be a potential locus of local development. Its identification and recognition as local institution (either because of those that work and live in it or because of those that act in the surrounding context are crucial steps to progressively constitute school as a partner for development. The promotion of the local values and roots, the reconstruction of socio-personal and local identities, the production of sociabilities and the equation and solution of shared problems were the dimensions of a socio-educative intervention, markedly globalising. This scenario, as it is argued, was also, intentionally, one of transformation and of deliberate change of school and of the administration of the educative territoires.

  19. Sound knowledge

    DEFF Research Database (Denmark)

    Kauffmann, Lene Teglhus

    as knowledge based on reflexive practices. I chose ‘health promotion’ as the field for my research as it utilises knowledge produced in several research disciplines, among these both quantitative and qualitative. I mapped out the institutions, actors, events, and documents that constituted the field of health...... of the research is to investigate what is considered to ‘work as evidence’ in health promotion and how the ‘evidence discourse’ influences social practices in policymaking and in research. From investigating knowledge practices in the field of health promotion, I develop the concept of sound knowledge...... result of a rigorous and standardized research method. However, this anthropological analysis shows that evidence and evidence-based is a hegemonic ‘way of knowing’ that sometimes transposes everyday reasoning into an epistemological form. However, the empirical material shows a variety of understandings...

  20. Intercepting a sound without vision

    Science.gov (United States)

    Vercillo, Tiziana; Tonelli, Alessia; Gori, Monica

    2017-01-01

    Visual information is extremely important to generate internal spatial representations. In the auditory modality, the absence of visual cues during early infancy does not preclude the development of some spatial strategies. However, specific spatial abilities might result impaired. In the current study, we investigated the effect of early visual deprivation on the ability to localize static and moving auditory stimuli by comparing sighted and early blind individuals’ performance in different spatial tasks. We also examined perceptual stability in the two groups of participants by matching localization accuracy in a static and a dynamic head condition that involved rotational head movements. Sighted participants accurately localized static and moving sounds. Their localization ability remained unchanged after rotational movements of the head. Conversely, blind participants showed a leftward bias during the localization of static sounds and a little bias for moving sounds. Moreover, head movements induced a significant bias in the direction of head motion during the localization of moving sounds. These results suggest that internal spatial representations might be body-centered in blind individuals and that in sighted people the availability of visual cues during early infancy may affect sensory-motor interactions. PMID:28481939

  1. Statistics of natural binaural sounds.

    Directory of Open Access Journals (Sweden)

    Wiktor Młynarski

    Full Text Available Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD and level (ILD disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA. Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  2. Statistics of natural binaural sounds.

    Science.gov (United States)

    Młynarski, Wiktor; Jost, Jürgen

    2014-01-01

    Binaural sound localization is usually considered a discrimination task, where interaural phase (IPD) and level (ILD) disparities at narrowly tuned frequency channels are utilized to identify a position of a sound source. In natural conditions however, binaural circuits are exposed to a stimulation by sound waves originating from multiple, often moving and overlapping sources. Therefore statistics of binaural cues depend on acoustic properties and the spatial configuration of the environment. Distribution of cues encountered naturally and their dependence on physical properties of an auditory scene have not been studied before. In the present work we analyzed statistics of naturally encountered binaural sounds. We performed binaural recordings of three auditory scenes with varying spatial configuration and analyzed empirical cue distributions from each scene. We have found that certain properties such as the spread of IPD distributions as well as an overall shape of ILD distributions do not vary strongly between different auditory scenes. Moreover, we found that ILD distributions vary much weaker across frequency channels and IPDs often attain much higher values, than can be predicted from head filtering properties. In order to understand the complexity of the binaural hearing task in the natural environment, sound waveforms were analyzed by performing Independent Component Analysis (ICA). Properties of learned basis functions indicate that in natural conditions soundwaves in each ear are predominantly generated by independent sources. This implies that the real-world sound localization must rely on mechanisms more complex than a mere cue extraction.

  3. Sound Search Engine Concept

    DEFF Research Database (Denmark)

    2006-01-01

    Sound search is provided by the major search engines, however, indexing is text based, not sound based. We will establish a dedicated sound search services with based on sound feature indexing. The current demo shows the concept of the sound search engine. The first engine will be realased June...

  4. Simulating Visibility Under Reduced Acuity and Contrast Sensitivity

    Science.gov (United States)

    Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan

    2017-01-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328

  5. Radiation-induced changes in taste acuity in cancer patients

    International Nuclear Information System (INIS)

    Mossman, K.L.; Henkin, R.I.

    1978-01-01

    Changes in taste acuity were measured in 27 patients with various forms of cancer who received radiation to the head and neck region. In 9 of these patients (group I), measurements of taste acuity were made more than 1 year after completion of radiation therapy. In the other 18 patients (group II), taste measurements were made before, during, and approximately 1 month after radiation therapy. Taste acuity was measured for four taste qualities (salt, sweet, sour, and bitter) by a forced choice-three stimulus drop technique which measured detection and recognition thresholds and by a forced scaling technique which measured taste intensity responsiveness. In group II patients, impaired acuity, as indicated by elevated detection and recognition thresholds, was observed approximately 3 weeks after initiation of radiotherapy. The bitter and salt qualities showed the earliest and greatest impairment and the sweet quality the least. Taste intensity responsiveness also was impaired in group II patients. As for thresholds, scaling impairment was most severe for bitter and salt taste qualities. Scaling impairment occurred before changes in either detection or recognition thresholds. Detection and recognition thresholds determined in group I patients also showed salt and bitter qualities were affected more severely than either sweet or sour qualities. Zinc administration to group I patients in an uncontrolled study suggested that zinc therapy may be useful in ameliorating taste impairment in some patients. These results suggest that taste loss may be a factor in the anorexia and weight loss that is observed commonly in patients who have undergone radiation treatment. Correction of this abnormality may be useful in aiding the nutritional status of these patients

  6. A new Snellen's visual acuity chart with 'Indian' numerals.

    OpenAIRE

    Al-Salem, M

    1987-01-01

    'Indian' numerals, which are popular among the Arab population, were used to devise a new Snellen's visual acuity chart. The new chart has the advantages of a reading chart. It keeps the patient's interest, does not miss alexic patients, and is quicker to perform. It is also devoid of the many disadvantages of a kinetic response chart (the capital E letter or Landolt's broken rings), especially that of the limited option of test objects.

  7. Eye size and visual acuity influence vestibular anatomy in mammals.

    Science.gov (United States)

    Kemp, Addison D; Christopher Kirk, E

    2014-04-01

    The semicircular canals of the inner ear detect head rotations and trigger compensatory movements that stabilize gaze and help maintain visual fixation. Mammals with large eyes and high visual acuity require precise gaze stabilization mechanisms because they experience diminished visual functionality at low thresholds of uncompensated motion. Because semicircular canal radius of curvature is a primary determinant of canal sensitivity, species with large canal radii are expected to be capable of more precise gaze stabilization than species with small canal radii. Here, we examine the relationship between mean semicircular canal radius of curvature, eye size, and visual acuity in a large sample of mammals. Our results demonstrate that eye size and visual acuity both explain a significant proportion of the variance in mean canal radius of curvature after statistically controlling for the effects of body mass and phylogeny. These findings suggest that variation in mean semicircular canal radius of curvature among mammals is partly the result of selection for improved gaze stabilization in species with large eyes and acute vision. Our results also provide a possible functional explanation for the small semicircular canal radii of fossorial mammals and plesiadapiforms. Copyright © 2014 Wiley Periodicals, Inc.

  8. Diagnosing cerebral visual impairment in children with good visual acuity.

    Science.gov (United States)

    van Genderen, Maria; Dekker, Marjoke; Pilon, Florine; Bals, Irmgard

    2012-06-01

    To identify elements that could facilitate the diagnosis of cerebral visual impairment (CVI) in children with good visual acuity in the general ophthalmic clinic. We retrospectively investigated the clinical characteristics of 30 children with good visual acuity and CVI and compared them with those of 23 children who were referred with a suspicion of CVI, but proved to have a different diagnosis. Clinical characteristics included medical history, MRI findings, visual acuity, crowding ratio (CR), visual field assessment, and the results of ophthalmologic and orthoptic examination. We also evaluated the additional value of a short CVI questionnaire. Eighty-three percent of the children with an abnormal medical history (mainly prematurity and perinatal hypoxia) had CVI, in contrast with none of the children with a normal medical history. Cerebral palsy, visual field defects, and partial optic atrophy only occurred in the CVI group. 41% of the children with CVI had a CR ≥2.0, which may be related to dorsal stream dysfunction. All children with CVI, but also 91% of the children without CVI gave ≥3 affirmative answers on the CVI questionnaire. An abnormal pre- or perinatal medical history is the most important risk factor for CVI in children, and therefore in deciding which children should be referred for further multidisciplinary assessment. Additional symptoms of cerebral damage, i.e., cerebral palsy, visual field defects, partial optic atrophy, and a CR ≥2 may support the diagnosis. CVI questionnaires should not be used for screening purposes as they yield too many false positives.

  9. NASA Space Sounds API

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA has released a series of space sounds via sound cloud. We have abstracted away some of the hassle in accessing these sounds, so that developers can play with...

  10. Fluctuation in visual acuity during soft toric contact lens wear.

    Science.gov (United States)

    Chamberlain, Paul; Morgan, Philip B; Moody, Kurt J; Maldonado-Codina, Carole

    2011-04-01

    To quantify changes in visual acuity (VA) with soft toric contact lenses as a result of lens movement and/or rotational instability caused by versional eye movements. A novel chart for vision assessment at near (40 cm) for soft toric contact lenses (VANT chart),consisting of a central, color-coded logMAR panel and eight peripheral letter targets set on a white background measuring 60 × 40 cm was constructed. In the developmental phase of the work, 10 subjects (20 eyes) wore 2 toric lenses in random order, and the impact of rapid and delayed eye versions in 8 directions of gaze on VANT acuity was investigated. In phase 2, 35 subjects (68 eyes) wore 4 toric lenses in random order, and a streamlined clinical protocol using the VANT chart was implemented. Standard assessments of toric lens fit and distance VA were also performed. Testing in the first phase showed no difference for change in VA for rapid vs. delayed version movements, (p = 0.17) but acuity reduction was greater for diagonal compared with horizontal/vertical versions (p = 0.06). As such, testing in phase 2 proceeded using rapid, diagonal versions only. In this second phase, there were differences for low-contrast distance VA measures between lens types (p = 0.02) and for both VANT baseline acuity (p = 0.03) and postversion acuity (p = 0.04), but no differences were found between lenses for magnitude of vision loss (p = 0.91), which was about one line. No relationship was established between the magnitude of vision loss and measured rotational stability (p = 0.75). This work has demonstrated that conventional approaches to measuring VA do not fully replicate the "real world" experience of soft toric lens wearers. The VANT chart has shown that VA is reduced immediately after versional eye movements and suggests that more dynamic methods of assessing visual performance should be considered for soft toric contact lens wearers, especially given the apparent inability of lens stability measurements to predict

  11. Effect of ocular transverse chromatic aberration on detection acuity for peripheral vision.

    Science.gov (United States)

    Cheney, Frank; Thibos, Larry; Bradley, Arthur

    2015-01-01

    We examined the effect of transverse chromatic aberration (TCA) on detection acuity for white-light interference fringes seen in Maxwellian view at various orientations and locations in the visual field. A circular patch (3.5° diameter, 3.2 log Trolands) of nominally high-contrast fringes was produced on the retina by a commercial instrument (the Lotmar Visometer, Haag Streit) mounted on a gimbal for controlled positioning of the stimulus in the visual field from 0° to 35° eccentricity. Detection acuity for white light fringes for all meridians and eccentricities ≥15° was maximum when fringes were oriented parallel to the visual meridian line. This meridional effect disappeared when a narrow-band filter was used to eliminate TCA. The meridional effect also disappeared when the interferometric stimulator was displaced laterally to align the instrument with the eye's local achromatic axis. Modelling confirmed that TCA is the major factor responsible for white-light meridional bias, with minor contribution arising from higher-order monochromatic aberrations and neural factors. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  12. Suppressive competition: how sounds may cheat sight.

    Science.gov (United States)

    Kayser, Christoph; Remedios, Ryan

    2012-02-23

    In this issue of Neuron, Iurilli et al. (2012) demonstrate that auditory cortex activation directly engages local GABAergic circuits in V1 to induce sound-driven hyperpolarizations in layer 2/3 and layer 6 pyramidal neurons. Thereby, sounds can directly suppress V1 activity and visual driven behavior. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Outcome of visual acuity after surgical removal of pituitary adenomas

    Directory of Open Access Journals (Sweden)

    Grković Desanka

    2013-01-01

    Full Text Available Introduction. Pituitary adenomas with suprasellar extension may produce anterior visual pathway compression, resulting in characteristic visual deficit. Surgical decompression of these structures prevents further visual deterioration and its postop­ erative recovery. Objective. The aim of this study was to investigate pre­ and postoperative visual acuity (VA in patients with pituitary ad­ enomas, and to detect the influence of prognostic factors, such as symptoms duration, degree of visual acuity reduction and tumor size in the assessment of the prognosis of postoperative visual function. Methods. We analyzed 40 consecutive patients who fulfilled three criteria: evidence of preoperative visual dysfunction, transsphenoidal or transfrontal tumor resection and hystologically verified pituitary adenoma. A visual examination was performed under standard conditions, pre and postoperatively (10 days, one month and six months after surgery. A paired t­test was used to assess the differences of pre­ and postoperative characteristics values, and the Chisquare test of independence in the assessment of the influence of prognostic factors. Results. Postoperative improvement of VA was seen in 84.61% patients (68% eyes. Eyes with preoperative mild and moderate degree of VA reduction showed improvement in 89.65% eyes in contrast to 22.60% eyes with preoperative severe reduction of VA, which was all statistically significant. Eyes in patients with tumor smaller than 20 mm had improvement of VA in 91.66% eyes, while eyes with tumor larger than 40 mm had improvement of VA in 61.11% eyes, which was statistically significant. When symptoms duration was below two years the improvement of VA was detected in 65.38% eyes as related to 50% eyes with symptoms duration exceeding two years, which was not statistically significant. Conclusion. Pituitary adenomas commonly cause visual impairment. Postoperatively the majority of patients show a distinct improvement of

  14. The influence of tongue strength on oral viscosity discrimination acuity.

    Science.gov (United States)

    Steele, Catriona M

    2018-06-01

    The ability to generate tongue pressures is widely considered to be critical for liquid bolus propulsion in swallowing. It has been proposed that the application of tongue pressure may also serve the function of collecting sensory information regarding bolus viscosity (resistance to flow). In this study, we explored the impact of age-related reductions in tongue strength on oral viscosity discrimination acuity. The experiment employed a triangle test discrimination protocol with an array of xanthan-gum thickened liquids in the mildly to moderately thick consistency range. A sample of 346 healthy volunteers was recruited, with age ranging from 12 to 86 (164 men, 182 women). On average, participants were able to detect a 0.29-fold increase in xanthan-gum concentration, corresponding to a 0.5-fold increase in viscosity at 50/s. Despite having significantly reduced tongue strength on maximum isometric tongue-palate pressure tasks, and regardless of sex, older participants in this study showed no reductions in viscosity discrimination acuity. In this article, the relationship between tongue strength and the ability to discriminate small differences in liquid viscosity during oral processing is explored. Given that tongue strength declines with age in healthy adults and is also reduced in individuals with dysphagia, it is interesting to determine whether reduced tongue strength might contribute to difficulties in evaluating liquid viscosity during the oral stage of swallowing. Using an array of mildly to moderately thick xanthan-gum thickened liquids, this experiment failed to find any evidence that reductions in tongue strength influence oral viscosity discrimination acuity. © 2017 Wiley Periodicals, Inc.

  15. The Sound of Science

    Science.gov (United States)

    Merwade, Venkatesh; Eichinger, David; Harriger, Bradley; Doherty, Erin; Habben, Ryan

    2014-01-01

    While the science of sound can be taught by explaining the concept of sound waves and vibrations, the authors of this article focused their efforts on creating a more engaging way to teach the science of sound--through engineering design. In this article they share the experience of teaching sound to third graders through an engineering challenge…

  16. Sounds Exaggerate Visual Shape

    Science.gov (United States)

    Sweeny, Timothy D.; Guzman-Martinez, Emmanuel; Ortega, Laura; Grabowecky, Marcia; Suzuki, Satoru

    2012-01-01

    While perceiving speech, people see mouth shapes that are systematically associated with sounds. In particular, a vertically stretched mouth produces a /woo/ sound, whereas a horizontally stretched mouth produces a /wee/ sound. We demonstrate that hearing these speech sounds alters how we see aspect ratio, a basic visual feature that contributes…

  17. Making Sound Connections

    Science.gov (United States)

    Deal, Walter F., III

    2007-01-01

    Sound provides and offers amazing insights into the world. Sound waves may be defined as mechanical energy that moves through air or other medium as a longitudinal wave and consists of pressure fluctuations. Humans and animals alike use sound as a means of communication and a tool for survival. Mammals, such as bats, use ultrasonic sound waves to…

  18. Little Sounds

    Directory of Open Access Journals (Sweden)

    Baker M. Bani-Khair

    2017-10-01

    Full Text Available The Spider and the Fly   You little spider, To death you aspire... Or seeking a web wider, To death all walking, No escape you all fighters… Weak and fragile in shape and might, Whatever you see in the horizon, That is destiny whatever sight. And tomorrow the spring comes, And the flowers bloom, And the grasshopper leaps high, And the frogs happily cry, And the flies smile nearby, To that end, The spider has a plot, To catch the flies by his net, A mosquito has fallen down in his net, Begging him to set her free, Out of that prison, To her freedom she aspires, Begging...Imploring...crying,  That is all what she requires, But the spider vows never let her free, His power he admires, Turning blind to light, And with his teeth he shall bite, Leaving her in desperate might, Unable to move from site to site, Tied up with strings in white, Wrapped up like a dead man, Waiting for his grave at night,   The mosquito says, Oh little spider, A stronger you are than me in power, But listen to my words before death hour, Today is mine and tomorrow is yours, No escape from death... Whatever the color of your flower…     Little sounds The Ant The ant is a little creature with a ferocious soul, Looking and looking for more and more, You can simply crush it like dead mold, Or you can simply leave it alone, I wonder how strong and strong they are! Working day and night in a small hole, Their motto is work or whatever you call… A big boon they have and joy in fall, Because they found what they store, A lesson to learn and memorize all in all, Work is something that you should not ignore!   The butterfly: I’m the butterfly Beautiful like a blue clear sky, Or sometimes look like snow, Different in colors, shapes and might, But something to know that we always die, So fragile, weak and thin, Lighter than a glimpse and delicate as light, Something to know for sure… Whatever you have in life and all these fields, You are not happier than a butterfly

  19. Electromagnetic sounding of the Earth's interior

    CERN Document Server

    Spichak, Viacheslav V

    2015-01-01

    Electromagnetic Sounding of the Earth's Interior 2nd edition provides a comprehensive up-to-date collection of contributions, covering methodological, computational and practical aspects of Electromagnetic sounding of the Earth by different techniques at global, regional and local scales. Moreover, it contains new developments such as the concept of self-consistent tasks of geophysics and , 3-D interpretation of the TEM sounding which, so far, have not all been covered by one book. Electromagnetic Sounding of the Earth's Interior 2nd edition consists of three parts: I- EM sounding methods, II- Forward modelling and inversion techniques, and III - Data processing, analysis, modelling and interpretation. The new edition includes brand new chapters on Pulse and frequency electromagnetic sounding for hydrocarbon offshore exploration. Additionally all other chapters have been extensively updated to include new developments. Presents recently developed methodological findings of the earth's study, including seism...

  20. Changes in brain morphology in albinism reflect reduced visual acuity.

    Science.gov (United States)

    Bridge, Holly; von dem Hagen, Elisabeth A H; Davies, George; Chambers, Claire; Gouws, Andre; Hoffmann, Michael; Morland, Antony B

    2014-07-01

    Albinism, in humans and many animal species, has a major impact on the visual system, leading to reduced acuity, lack of binocular function and nystagmus. In addition to the lack of a foveal pit, there is a disruption to the routing of the nerve fibers crossing at the optic chiasm, resulting in excessive crossing of fibers to the contralateral hemisphere. However, very little is known about the effect of this misrouting on the structure of the post-chiasmatic visual pathway, and the occipital lobes in particular. Whole-brain analyses of cortical thickness in a large cohort of subjects with albinism showed an increase in cortical thickness, relative to control subjects, particularly in posterior V1, corresponding to the foveal representation. Furthermore, mean cortical thickness across entire V1 was significantly greater in these subjects compared to controls and negatively correlated with visual acuity in albinism. Additionally, the group with albinism showed decreased gyrification in the left ventral occipital lobe. While the increase in cortical thickness in V1, also found in congenitally blind subjects, has been interpreted to reflect a lack of pruning, the decreased gyrification in the ventral extrastriate cortex may reflect the reduced input to the foveal regions of the ventral visual stream. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Influences of multiple memory systems on auditory mental image acuity.

    Science.gov (United States)

    Navarro Cebrian, Ana; Janata, Petr

    2010-05-01

    The influence of different memory systems and associated attentional processes on the acuity of auditory images, formed for the purpose of making intonation judgments, was examined across three experiments using three different task types (cued-attention, imagery, and two-tone discrimination). In experiment 1 the influence of implicit long-term memory for musical scale structure was manipulated by varying the scale degree (leading tone versus tonic) of the probe note about which a judgment had to be made. In experiments 2 and 3 the ability of short-term absolute pitch knowledge to develop was manipulated by presenting blocks of trials in the same key or in seven different keys. The acuity of auditory images depended on all of these manipulations. Within individual listeners, thresholds in the two-tone discrimination and cued-attention conditions were closely related. In many listeners, cued-attention thresholds were similar to thresholds in the imagery condition, and depended on the amount of training individual listeners had in playing a musical instrument. The results indicate that mental images formed at a sensory/cognitive interface for the purpose of making perceptual decisions are highly malleable.

  2. Distinct eye movement patterns enhance dynamic visual acuity

    Science.gov (United States)

    Palidis, Dimitrios J.; Wyder-Hodge, Pearson A.; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics—eye latency, acceleration, velocity gain, position error—and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns—minimizing eye position error, tracking smoothly, and inhibiting reverse saccades—were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA. PMID:28187157

  3. Distinct eye movement patterns enhance dynamic visual acuity.

    Science.gov (United States)

    Palidis, Dimitrios J; Wyder-Hodge, Pearson A; Fooken, Jolande; Spering, Miriam

    2017-01-01

    Dynamic visual acuity (DVA) is the ability to resolve fine spatial detail in dynamic objects during head fixation, or in static objects during head or body rotation. This ability is important for many activities such as ball sports, and a close relation has been shown between DVA and sports expertise. DVA tasks involve eye movements, yet, it is unclear which aspects of eye movements contribute to successful performance. Here we examined the relation between DVA and the kinematics of smooth pursuit and saccadic eye movements in a cohort of 23 varsity baseball players. In a computerized dynamic-object DVA test, observers reported the location of the gap in a small Landolt-C ring moving at various speeds while eye movements were recorded. Smooth pursuit kinematics-eye latency, acceleration, velocity gain, position error-and the direction and amplitude of saccadic eye movements were linked to perceptual performance. Results reveal that distinct eye movement patterns-minimizing eye position error, tracking smoothly, and inhibiting reverse saccades-were related to dynamic visual acuity. The close link between eye movement quality and DVA performance has important implications for the development of perceptual training programs to improve DVA.

  4. Stimulus-dependent effects on tactile spatial acuity

    Directory of Open Access Journals (Sweden)

    Tommerdahl M

    2005-10-01

    Full Text Available Abstract Background Previous studies have shown that spatio-tactile acuity is influenced by the clarity of the cortical response in primary somatosensory cortex (SI. Stimulus characteristics such as frequency, amplitude, and location of tactile stimuli presented to the skin have been shown to have a significant effect on the response in SI. The present study observes the effect of changing stimulus parameters of 25 Hz sinusoidal vertical skin displacement stimulation ("flutter" on a human subject's ability to discriminate between two adjacent or near-adjacent skin sites. Based on results obtained from recent neurophysiological studies of the SI response to different conditions of vibrotactile stimulation, we predicted that the addition of 200 Hz vibration to the same site that a two-point flutter stimulus was delivered on the skin would improve a subject's spatio-tactile acuity over that measured with flutter alone. Additionally, similar neurophysiological studies predict that the presence of either a 25 Hz flutter or 200 Hz vibration stimulus on the unattended hand (on the opposite side of the body from the site of two-point limen testing – the condition of bilateral stimulation – which has been shown to evoke less SI cortical activity than the contralateral-only stimulus condition would decrease a subject's ability to discriminate between two points on the skin. Results A Bekesy tracking method was employed to track a subject's ability to discriminate between two-point stimuli delivered to the skin. The distance between the two points of stimulation was varied on a trial-by-trial basis, and several different stimulus conditions were examined: (1 The "control" condition, in which 25 Hz flutter stimuli were delivered simultaneously to the two points on the skin of the attended hand, (2 the "complex" condition, in which a combination of 25 Hz flutter and 200 Hz vibration stimuli were delivered to the two points on the attended hand, and (3 a

  5. [The relationship between eyeball structure and visual acuity in high myopia].

    Science.gov (United States)

    Liu, Yi-Chang; Xia, Wen-Tao; Zhu, Guang-You; Zhou, Xing-Tao; Fan, Li-Hua; Liu, Rui-Jue; Chen, Jie-Min

    2010-06-01

    To explore the relationship between eyeball structure and visual acuity in high myopia. Totally, 152 people (283 eyeballs) with different levels of myopia were tested for visual acuity, axial length, and fundus. All cases were classified according to diopter, axial length, and fundus. The relationships between diopter, axial length, fundus and visual acuity were studied. The mathematical models were established for visual acuity and eyeball structure markers. The visual acuity showed a moderate correlation with fundus class, comus, axial length and diopter ([r] > 0.4, P eyeball structure markers. The visual acuity should decline with axial length extension, diopter deepening and pathological deterioration of fundus. To detect the structure changes by combining different kinds of objective methods can help to assess and to judge the vision in high myopia.

  6. Testbed for High-Acuity Imaging and Stable Photometry

    Science.gov (United States)

    Gregory, James

    This proposal from MIT Lincoln Laboratory (LL) accompanies the NASA/APRA proposal enti-tled THAI-SPICE: Testbed for High-Acuity Imaging - Stable Photometry and Image-Motion Compensa-tion Experiment (submitted by Eliot Young, Southwest Research Institute). The goal of the THAI-SPICE project is to demonstrate three technologies that will help low-cost balloon-borne telescopes achieve diffraction-limited imaging: stable pointing, passive thermal stabilization and in-flight monitoring of the wave front error. This MIT LL proposal supplies a key element of the pointing stabilization component of THAI-SPICE: an electronic camera based on an orthogonaltransfer charge-coupled device (OTCCD). OTCCD cameras have been demonstrated with charge-transfer efficiencies >0.99999, noise of 90%. In addition to supplying a camera with an OTCCD detector, MIT LL will help with integration and testing of the OTCCD with the THAI-SPICE payload’s guide camera.

  7. Experimental validation of a Bayesian model of visual acuity.

    LENUS (Irish Health Repository)

    Dalimier, Eugénie

    2009-01-01

    Based on standard procedures used in optometry clinics, we compare measurements of visual acuity for 10 subjects (11 eyes tested) in the presence of natural ocular aberrations and different degrees of induced defocus, with the predictions given by a Bayesian model customized with aberrometric data of the eye. The absolute predictions of the model, without any adjustment, show good agreement with the experimental data, in terms of correlation and absolute error. The efficiency of the model is discussed in comparison with image quality metrics and other customized visual process models. An analysis of the importance and customization of each stage of the model is also given; it stresses the potential high predictive power from precise modeling of ocular and neural transfer functions.

  8. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    OpenAIRE

    Jonathan S. Pointer

    2008-01-01

    Purpose: To quantify the difference between recognition (letter) and resolution (Landolt) visual acuity (VA) in a group of normally sighted subjects. Is it reasonable to assume that the two acuity measures are clinically equivalent? Methods: A pair of 6 m acuity test charts was produced: one comprised letters and the other Landolt broken rings. Construction of both charts conformed to the logMAR design format. Monocular VA was determined for the dominant eye of 300 screened and normally si...

  9. Sound wave transmission (image)

    Science.gov (United States)

    When sounds waves reach the ear, they are translated into nerve impulses. These impulses then travel to the brain where they are interpreted by the brain as sound. The hearing mechanisms within the inner ear, can ...

  10. Making fictions sound real

    DEFF Research Database (Denmark)

    Langkjær, Birger

    2010-01-01

    This article examines the role that sound plays in making fictions perceptually real to film audiences, whether these fictions are realist or non-realist in content and narrative form. I will argue that some aspects of film sound practices and the kind of experiences they trigger are related...... to basic rules of human perception, whereas others are more properly explained in relation to how aesthetic devices, including sound, are used to characterise the fiction and thereby make it perceptually real to its audience. Finally, I will argue that not all genres can be defined by a simple taxonomy...... of sounds. Apart from an account of the kinds of sounds that typically appear in a specific genre, a genre analysis of sound may also benefit from a functionalist approach that focuses on how sounds can make both realist and non-realist aspects of genres sound real to audiences....

  11. Principles of underwater sound

    National Research Council Canada - National Science Library

    Urick, Robert J

    1983-01-01

    ... the immediately useful help they need for sonar problem solving. Its coverage is broad-ranging from the basic concepts of sound in the sea to making performance predictions in such applications as depth sounding, fish finding, and submarine detection...

  12. An Antropologist of Sound

    DEFF Research Database (Denmark)

    Groth, Sanne Krogh

    2015-01-01

    PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology.......PROFESSOR PORTRAIT: Sanne Krogh Groth met Holger Schulze, newly appointed professor in Musicology at the Department for Arts and Cultural Studies, University of Copenhagen, to a talk about anthropology of sound, sound studies, musical canons and ideology....

  13. Broadcast sound technology

    CERN Document Server

    Talbot-Smith, Michael

    1990-01-01

    Broadcast Sound Technology provides an explanation of the underlying principles of modern audio technology. Organized into 21 chapters, the book first describes the basic sound; behavior of sound waves; aspects of hearing, harming, and charming the ear; room acoustics; reverberation; microphones; phantom power; loudspeakers; basic stereo; and monitoring of audio signal. Subsequent chapters explore the processing of audio signal, sockets, sound desks, and digital audio. Analogue and digital tape recording and reproduction, as well as noise reduction, are also explained.

  14. Propagation of sound

    DEFF Research Database (Denmark)

    Wahlberg, Magnus; Larsen, Ole Næsbye

    2017-01-01

    properties can be modified by sound absorption, refraction, and interference from multi paths caused by reflections.The path from the source to the receiver may be bent due to refraction. Besides geometrical attenuation, the ground effect and turbulence are the most important mechanisms to influence...... communication sounds for airborne acoustics and bottom and surface effects for underwater sounds. Refraction becomes very important close to shadow zones. For echolocation signals, geometric attenuation and sound absorption have the largest effects on the signals....

  15. Sparse representation of Gravitational Sound

    Science.gov (United States)

    Rebollo-Neira, Laura; Plastino, A.

    2018-03-01

    Gravitational Sound clips produced by the Laser Interferometer Gravitational-Wave Observatory (LIGO) and the Massachusetts Institute of Technology (MIT) are considered within the particular context of data reduction. We advance a procedure to this effect and show that these types of signals can be approximated with high quality using significantly fewer elementary components than those required within the standard orthogonal basis framework. Furthermore, a local measure sparsity is shown to render meaningful information about the variation of a signal along time, by generating a set of local sparsity values which is much smaller than the dimension of the signal. This point is further illustrated by recourse to a more complex signal, generated by Milde Science Communication to divulge Gravitational Sound in the form of a ring tone.

  16. Abnormal sound detection device

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji.

    1995-01-01

    Only components synchronized with rotation of pumps are sampled from detected acoustic sounds, to judge the presence or absence of abnormality based on the magnitude of the synchronized components. A synchronized component sampling means can remove resonance sounds and other acoustic sounds generated at a synchronously with the rotation based on the knowledge that generated acoustic components in a normal state are a sort of resonance sounds and are not precisely synchronized with the number of rotation. On the other hand, abnormal sounds of a rotating body are often caused by compulsory force accompanying the rotation as a generation source, and the abnormal sounds can be detected by extracting only the rotation-synchronized components. Since components of normal acoustic sounds generated at present are discriminated from the detected sounds, reduction of the abnormal sounds due to a signal processing can be avoided and, as a result, abnormal sound detection sensitivity can be improved. Further, since it is adapted to discriminate the occurrence of the abnormal sound from the actually detected sounds, the other frequency components which are forecast but not generated actually are not removed, so that it is further effective for the improvement of detection sensitivity. (N.H.)

  17. Modelling Hyperboloid Sound Scattering

    DEFF Research Database (Denmark)

    Burry, Jane; Davis, Daniel; Peters, Brady

    2011-01-01

    The Responsive Acoustic Surfaces workshop project described here sought new understandings about the interaction between geometry and sound in the arena of sound scattering. This paper reports on the challenges associated with modelling, simulating, fabricating and measuring this phenomenon using...... both physical and digital models at three distinct scales. The results suggest hyperboloid geometry, while difficult to fabricate, facilitates sound scattering....

  18. Errors in Sounding of the Atmosphere Using Broadband Emission Radiometry (SABER) Kinetic Temperature Caused by Non-Local Thermodynamic Equilibrium Model Parameters

    Science.gov (United States)

    Garcia-Comas, Maya; Lopez-Puertas, M.; Funke, B.; Bermejo-Pantaleon, D.; Marshall, Benjamin T.; Mertens, Christopher J.; Remsberg, Ellis E.; Mlynczak, Martin G.; Gordley, L. L.; Russell, James M.

    2008-01-01

    The vast set of near global and continuous atmospheric measurements made by the SABER instrument since 2002, including daytime and nighttime kinetic temperature (T(sub k)) from 20 to 105 km, is available to the scientific community. The temperature is retrieved from SABER measurements of the atmospheric 15 micron CO2 limb emission. This emission separates from local thermodynamic equilibrium (LTE) conditions in the rarefied mesosphere and thermosphere, making it necessary to consider the CO2 vibrational state non-LTE populations in the retrieval algorithm above 70 km. Those populations depend on kinetic parameters describing the rate at which energy exchange between atmospheric molecules take place, but some of these collisional rates are not well known. We consider current uncertainties in the rates of quenching of CO2 (v2 ) by N2 , O2 and O, and the CO2 (v2 ) vibrational-vibrational exchange to estimate their impact on SABER T(sub k) for different atmospheric conditions. The T(sub k) is more sensitive to the uncertainty in the latter two and their effects depend on altitude. The T(sub k) combined systematic error due to non-LTE kinetic parameters does not exceed +/- 1.5 K below 95 km and +/- 4-5 K at 100 km for most latitudes and seasons (except for polar summer) if the Tk profile does not have pronounced vertical structure. The error is +/- 3 K at 80 km, +/- 6 K at 84 km and +/- 18 K at 100 km under the less favourable polar summer conditions. For strong temperature inversion layers, the errors reach +/- 3 K at 82 km and +/- 8 K at 90 km. This particularly affects tide amplitude estimates, with errors of up to +/- 3 K.

  19. Effects of lighting and task parameters on visual acuity and performance

    Energy Technology Data Exchange (ETDEWEB)

    Halonen, L.

    1993-12-31

    Lighting and task parameters and their effects on visual acuity and visual performance are dealt with. The parameters studied are target contrast, target size and subject`s age; and also adaptation luminance, luminance ratio between task and its surrounding and temporal change in luminances are studied. Experiments were carried out to examine the effects of luminance and light spectrum on visual acuity. Young normally sighted, older and low vision people participated in the measurements. In the young and older subject groups the visual acuity remained unchanged at contrasts 0.93 and 0.63 at the luminance range of 15-630 cd/m{sub 2}. The results show that at contrasts 0.03-0.93 young and older subjects` visual acuity remained unchanged in the luminance range of 105-630 cd/m{sub 2}. In the low vision group, the changes in luminances between 25-860 cd/m{sub 2} did not have significant effects on visual acuity measured at high contrast 0.93, at low contrast, slight individual changes were found. The colour temperature of the light sources was altered between 2900-9500 K in the experiment. In the groups of the older, young and low vision subjects the light spectrum did not have significant effects on visual acuity, except for two retinitis pigmentosa subjects. On the basis of the visual acuity experiments, a three dimensional visual acuity model (VA-HUT) has been developed. The model predicts visual acuity as a function of luminance, target contrast and observer age. On the basis of visual acuity experiments visual acuity reserve values have been calculated for different text sizes

  20. Analysis of environmental sounds

    Science.gov (United States)

    Lee, Keansub

    consumer videos in conjunction with user studies. We model the soundtrack of each video, regardless of its original duration, as a fixed-sized clip-level summary feature. For each concept, an SVM-based classifier is trained according to three distance measures (Kullback-Leibler, Bhattacharyya, and Mahalanobis distance). Detecting the time of occurrence of a local object (for instance, a cheering sound) embedded in a longer soundtrack is useful and important for applications such as search and retrieval in consumer video archives. We finally present a Markov-model based clustering algorithm able to identify and segment consistent sets of temporal frames into regions associated with different ground-truth labels, and at the same time to exclude a set of uninformative frames shared in common from all clips. The labels are provided at the clip level, so this refinement of the time axis represents a variant of Multiple-Instance Learning (MIL). Quantitative evaluation shows that the performance of our proposed approaches tested on the 60h personal audio archives or 1900 YouTube video clips is significantly better than existing algorithms for detecting these useful concepts in real-world personal audio recordings.

  1. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: Dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1993, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. 9 patients were excluded from analysis secondary to co-morbidities or disease progression. 43 records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in (7(63)) (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to treat

  2. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. Nine patients were excluded from analysis secondary to co-morbidities or disease progression. Forty-three records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in 7/63 (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to

  3. The influence of ski helmets on sound perception and sound localisation on the ski slope

    Directory of Open Access Journals (Sweden)

    Lana Ružić

    2015-04-01

    Full Text Available Objectives: The aim of the study was to investigate whether a ski helmet interferes with the sound localization and the time of sound perception in the frontal plane. Material and Methods: Twenty-three participants (age 30.7±10.2 were tested on the slope in 2 conditions, with and without wearing the ski helmet, by 6 different spatially distributed sound stimuli per each condition. Each of the subjects had to react when hearing the sound as soon as possible and to signalize the correct side of the sound arrival. Results: The results showed a significant difference in the ability to localize the specific ski sounds; 72.5±15.6% of correct answers without a helmet vs. 61.3±16.2% with a helmet (p < 0.01. However, the performance on this test did not depend on whether they were used to wearing a helmet (p = 0.89. In identifying the timing, at which the sound was firstly perceived, the results were also in favor of the subjects not wearing a helmet. The subjects reported hearing the ski sound clues at 73.4±5.56 m without a helmet vs. 60.29±6.34 m with a helmet (p < 0.001. In that case the results did depend on previously used helmets (p < 0.05, meaning that that regular usage of helmets might help to diminish the attenuation of the sound identification that occurs because of the helmets. Conclusions: Ski helmets might limit the ability of a skier to localize the direction of the sounds of danger and might interfere with the moment, in which the sound is firstly heard.

  4. Presenting visual acuities in a new eye centre in Port Harcourt: initial ...

    African Journals Online (AJOL)

    Background: Visual acuity is a fundamental of an eye examination. It establishes in a quantitative way how well an eye can see. Apart from being a starting point in dealing with an eye, it is also a prognostic reference point and a medico-legal tool. Very few studies directly related to visual acuities are available as many ...

  5. When approximate number acuity predicts math performance: The moderating role of math anxiety

    Science.gov (United States)

    Libertus, Melissa E.

    2018-01-01

    Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS) have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments. PMID:29718939

  6. Tactile acuity is disrupted in osteoarthritis but is unrelated to disruptions in motor imagery performance.

    NARCIS (Netherlands)

    Stanton, T.R.; Lin, C.W.; Bray, H.; Smeets, R.J.P.; Taylor, D.; Law, R.Y.; Moseley, G.L.

    2013-01-01

    OBJECTIVE: To determine whether tactile acuity is disrupted in people with knee OA and to determine whether tactile acuity, a clinical signature of primary sensory cortex representation, is related to motor imagery performance (MIP; evaluates working body schema) and pain. METHODS: Experiment 1:

  7. When approximate number acuity predicts math performance: The moderating role of math anxiety.

    Science.gov (United States)

    Braham, Emily J; Libertus, Melissa E

    2018-01-01

    Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS) have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments.

  8. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Science.gov (United States)

    Pointer, Jonathan S.

    2010-01-01

    Purpose To quantify the difference between recognition (letter) and resolution (Landolt) visual acuity (VA) in a group of normally sighted subjects. Is it reasonable to assume that the two acuity measures are clinically equivalent? Methods A pair of 6 m acuity test charts was produced: one comprised letters and the other Landolt broken rings. Construction of both charts conformed to the logMAR design format. Monocular VA was determined for the dominant eye of 300 screened and normally sighted optometric patients aged 16 to 40, each wearing an optical refractive (spectacle) correction. Results Letter acuity was superior to Landolt acuity (P≤0.0001). The mean paired acuity difference was -0.041 logMAR (standard deviation 0.034): the 95% limits of agreement were ±0.067 logMAR units or ±3.3 chart optotype. Repeatability was high and similar for each chart type (±2.1 and ±2.4 optotype for letter and Landolt, respectively). Gender, test sequence, and laterality of the dominant eye (left or right) were each non-statistically significant variables. Conclusions For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  9. Recognition versus Resolution: a Comparison of Visual Acuity Results Using Two Alternative Test Chart Optotype

    Directory of Open Access Journals (Sweden)

    Jonathan S. Pointer

    2008-01-01

    Conclusions: For normally sighted subjects wearing an optimal refractive correction, a bias was recorded in favour of recognition over resolution acuity: the clinical difference amounted to approximately 40% of one logMAR chart line, with similar high repeatability for either chart optotype. We conclude that the assumption of clinical equivalence between letter and Landolt acuity is reasonable under optimum test conditions.

  10. When approximate number acuity predicts math performance: The moderating role of math anxiety.

    Directory of Open Access Journals (Sweden)

    Emily J Braham

    Full Text Available Separate lines of research suggest that people who are better at estimating numerical quantities using the approximate number system (ANS have better math performance, and that people with high levels of math anxiety have worse math performance. Only a handful of studies have examined both ANS acuity and math anxiety in the same participants and those studies report contradictory results. To address these inconsistencies, in the current study 87 undergraduate students completed assessments of ANS acuity, math anxiety, and three different measures of math. We considered moderation models to examine the interplay of ANS acuity and math anxiety on different aspects of math performance. Math anxiety and ANS acuity were both unique significant predictors of the ability to automatically recall basic number facts. ANS acuity was also a unique significant predictor of the ability to solve applied math problems, and this relation was further qualified by a significant interaction with math anxiety: the positive association between ANS acuity and applied problem solving was only present in students with high math anxiety. Our findings suggest that ANS acuity and math anxiety are differentially related to various aspects of math and should be considered together when examining their respective influences on math ability. Our findings also raise the possibility that good ANS acuity serves as a protective factor for highly math-anxious students on certain types of math assessments.

  11. Tactile spatial acuity in childhood: effects of age and fingertip size.

    Directory of Open Access Journals (Sweden)

    Ryan M Peters

    Full Text Available Tactile acuity is known to decline with age in adults, possibly as the result of receptor loss, but less is understood about how tactile acuity changes during childhood. Previous research from our laboratory has shown that fingertip size influences tactile spatial acuity in young adults: those with larger fingers tend to have poorer acuity, possibly because mechanoreceptors are more sparsely distributed in larger fingers. We hypothesized that a similar relationship would hold among children. If so, children's tactile spatial acuity might be expected to worsen as their fingertips grow. However, concomitant CNS maturation might result in more efficient perceptual processing, counteracting the effect of fingertip growth on tactile acuity. To investigate, we conducted a cross-sectional study, testing 116 participants ranging in age from 6 to 16 years on a precision-controlled tactile grating orientation task. We measured each participant's grating orientation threshold on the dominant index finger, along with physical properties of the fingertip: surface area, volume, sweat pore spacing, and temperature. We found that, as in adults, children with larger fingertips (at a given age had significantly poorer acuity, yet paradoxically acuity did not worsen significantly with age. We propose that finger growth during development results in a gradual decline in innervation density as receptive fields reposition to cover an expanding skin surface. At the same time, central maturation presumably enhances perceptual processing.

  12. Should we add visual acuity ratios to referral criteria for potential cerebral visual impairment?

    Science.gov (United States)

    van der Zee, Ymie J; Stiers, Peter; Evenhuis, Heleen M

    To determine whether the assessment of visual acuity ratios might improve the referral of children with (sub)normal visual acuity but at risk of cerebral visual impairment. In an exploratory study, we assessed visual acuity, crowding ratio and the ratios between grating acuity (Teller Acuity Cards-II) and optotype acuity (Cambridge Crowding Cards) in 60 typically developing school children (mean age 5y8m±1y1m), 21 children with ocular abnormalities only (5y7m±1y9m) and 26 children with (suspected) brain damage (5y7m±1y11m). Sensitivities and specificities were calculated for targets and controls from the perspective of different groups of diagnosticians: youth health care professionals (target: children with any visual abnormalities), ophthalmologists and low vision experts (target: children at risk of cerebral visual impairment). For youth health care professionals subnormal visual acuity had the best sensitivity (76%) and specificity (70%). For ophthalmologists and low vision experts the crowding ratio had the best sensitivity (67%) and specificity (79 and 86%). Youth health care professionals best continue applying subnormal visual acuity for screening, whereas ophthalmologists and low vision experts best add the crowding ratio to their routine diagnostics, to distinguish children at risk of visual impairment in the context of brain damage from children with ocular pathology only. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  13. 78 FR 13869 - Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy...

    Science.gov (United States)

    2013-03-01

    ...-123-LNG; 12-128-NG; 12-148-NG; 12- 158-NG] Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; Puget Sound Energy, Inc.; CE FLNG, LLC; Consolidated...-NG Puget Sound Energy, Inc Order granting long- term authority to import/export natural gas from/to...

  14. The natural horn as an efficient sound radiating system ...

    African Journals Online (AJOL)

    Results obtained showed that the locally made horn are efficient sound radiating systems and are therefore excellent for sound production in local musical renditions. These findings, in addition to the portability and low cost of the horns qualify them to be highly recommended for use in music making and for other purposes ...

  15. Binaural Processing of Multiple Sound Sources

    Science.gov (United States)

    2016-08-18

    AFRL-AFOSR-VA-TR-2016-0298 Binaural Processing of Multiple Sound Sources William Yost ARIZONA STATE UNIVERSITY 660 S MILL AVE STE 312 TEMPE, AZ 85281...18-08-2016 2. REPORT TYPE Final Performance 3. DATES COVERED (From - To) 15 Jul 2012 to 14 Jul 2016 4. TITLE AND SUBTITLE Binaural Processing of...three topics cited above are entirely within the scope of the AFOSR grant. 15. SUBJECT TERMS Binaural hearing, Sound Localization, Interaural signal

  16. Visual acuity after Ruthenium106 brachytherapy of choroidal melanomas

    International Nuclear Information System (INIS)

    Damato, Bertil; Patel, Imran M.; Campbell, Ian R.; Mayles, Helen M.; Errington, R. Douglas

    2005-01-01

    Purpose: To report on conservation of visual acuity after Ruthenium 106 (Ru-106) brachytherapy of choroidal melanoma. Methods and materials: This study was a noncomparative interventional case series of 458 patients with choroidal melanoma treated at a single center between January 1993 and December 2001. The intervention consisted of Ru-106 brachytherapy delivering minimum scleral and apex doses of 300 Gy and 80 Gy, respectively, using a 15-mm or 20-mm plaque. For discrete, posterior tumors, the plaque was positioned eccentrically with its posterior edge aligned with the posterior tumor margin. To ensure correct plaque positioning, any overlying extraocular muscles were dis-inserted, and the locations of both tumor and plaque edges were confirmed by transillumination and indentation. The main outcome measures were conservation of vision of 20/40 or better, 20/200 or better, and Counting Fingers or better, according to baseline variables. Results: The actuarial rate of conservation of 20/40 or better was 55% at 9 years, loss of such vision correlating with posterior tumor extension (p 106 brachytherapy of posterior choroidal melanoma achieves good conservation of vision if the tumor does not extend close to the optic nerve or fovea

  17. Analysis of relationship among visual evoked potential, oscillatory potential and visual acuity under stimulated weightlessness

    Directory of Open Access Journals (Sweden)

    Jun Zhao

    2013-05-01

    Full Text Available AIM: To observe the influence of head-down tilt simulated weightlessness on visual evoked potential(VEP, oscillatory potentials(OPsand visual acuity, and analyse the relationship among them. METHODS: Head-down tilt for -6° was adopted in 14 healthy volunteers. Distant visual acuity, near visual acuity, VEP and OPs were recorded before, two days and five days after trial. The record procedure of OPs followed the ISCEV standard for full-field clinical electroretinography(2008 update. RESULTS: Significant differences were detected in the amplitude of P100 waves and ∑OPs among various time points(P<0.05. But no relationship was observed among VEP, OPs and visual acuity. CONCLUSION: Head-down tilt simulated weightlessness induce the rearrange of blood of the whole body including eyes, which can make the change of visual electrophysiology but not visual acuity.

  18. Female carpet weavers' visual acuity and effective factors: Fordu rural area of Qom

    Directory of Open Access Journals (Sweden)

    Khajenasiri F.

    2007-11-01

    Full Text Available Background: Healthy vision of workers is one of the important elements in carpet weaving industry which has essential role in improving of the job quality and efficiency. Visual acuity is the primary outcome measure in most studies involving eye diseases. Ihe aim of this study was determination of visual acuity and its effective factors in women carpet weaver in fordu rural area of Qom has been investigated.  Methods: In a cross-sectional (descriptive-analytical study visual acuity of 177 women carpet weaver has been determined. Job hours per day, job history, age, literacy, trauma history, diabetes history, family history of eye diseases, eye diseases history and family size  of subjects were determined .Results: The results of study indicated that the right eyes visual acuity of 72.4 % of women were desirable (0 - 0.8 and 27.6 % were undesirable (0.9-1.2. These results for the left eyes were 69.5 % and 30.5 % respectively. In addition, the result showed that with increasing the job hours and history and age, percent of women with undesirable both eyes visual acuity were increased. With higher literacy levels, percent of women with undesirable both eyes visual acuity decreased. In subjects with truma history, the undesirable visual acuity was higher. In this study the relation between visual acuity and job history, age, literacy, truma history and eye diseases history were statistically significant (in all cases P<0.05.Conclusions: High percentage of women carpet weaver were in undesirable  visual acuity and in this study the relation between visual acuity and job history, age, literacy, trauma history and eye diseases history were statistically significant (in all cases P<0.05.

  19. Sound a very short introduction

    CERN Document Server

    Goldsmith, Mike

    2015-01-01

    Sound is integral to how we experience the world, in the form of noise as well as music. But what is sound? What is the physical basis of pitch and harmony? And how are sound waves exploited in musical instruments? Sound: A Very Short Introduction looks at the science of sound and the behaviour of sound waves with their different frequencies. It also explores sound in different contexts, covering the audible and inaudible, sound underground and underwater, acoustic and electronic sound, and hearing in humans and animals. It concludes with the problem of sound out of place—noise and its reduction.

  20. Sound Insulation between Dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2011-01-01

    Regulatory sound insulation requirements for dwellings exist in more than 30 countries in Europe. In some countries, requirements have existed since the 1950s. Findings from comparative studies show that sound insulation descriptors and requirements represent a high degree of diversity...... and initiate – where needed – improvement of sound insulation of new and existing dwellings in Europe to the benefit of the inhabitants and the society. A European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs...... 2009-2013. The main objectives of TU0901 are to prepare proposals for harmonized sound insulation descriptors and for a European sound classification scheme with a number of quality classes for dwellings. Findings from the studies provide input for the discussions in COST TU0901. Data collected from 24...

  1. [Dice test--a simple method for assessment of visual acuity in infants with visual deficits].

    Science.gov (United States)

    Rohrschneider, K; Brill, B; Bayer, Y; Ahrens, P

    2010-07-01

    Determination of visual acuity in low vision infants or patients with additional cerebral retardation is difficult. In our low vision department we used dice of different sizes and colors as well as other defined objects to determine visual acuity (VA). In this study we compared the results of the dice test with conventional tests for measurement of visual acuity. A total of 88 children with different causes of visual impairment e.g. albinism, retinal scars, retinopathy of prematurity (ROP), achromatopsia and optic atrophy etc., were included in this longitudinal study. Median follow-up time was 8.7 years (range 2.9-18.9 years). The first reliable examination was performed between the ages of 4 and 24 months (median 11 months). We estimated VA depending on the edge length of the dice, which were recognized at a distance of 30 cm, while 4 mm complied with VA 20/200. Best corrected binocular visual acuity was compared between the dice test, measurement with the Lea symbols and with numbers or Landolt rings. Estimation of visual acuity using the dice test was possible at the end of the first year of life (median 11 months, range 4-27 months). Although observation is limited to visual acuity results in the low vision range between light reaction and 20/120 there was nearly complete agreement between all three VA measurements. Visual acuity ranged from light perception to 20/20 with a median of 20/100. In 39 patients visual acuity was 20/200 or less at the end of the observation period. Visual acuity estimation overestimated visual acuity only in 5 out of the 88 patients, while in all of the patients with later acuity measurements better than 20/200, our best value of 20/200 was achieved. Using simple visual objects, such as dice with different colors and size down to an edge length of 4 mm, it is possible to estimate visual acuity in low vision infants within the first year of life. This option is also very helpful in patients who are not able to perform other visual

  2. The velocity of sound

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews the work carried out on the velocity of sound in liquid alkali metals. The experimental methods to determine the velocity measurements are described. Tables are presented of reported data on the velocity of sound in lithium, sodium, potassium, rubidium and caesium. A formula is given for alkali metals, in which the sound velocity is a function of shear viscosity, atomic mass and atomic volume. (U.K.)

  3. Michael Jackson's Sound Stages

    OpenAIRE

    Morten Michelsen

    2012-01-01

    In order to discuss analytically spatial aspects of recorded sound William Moylan’s concept of ‘sound stage’ is developed within a musicological framework as part of a sound paradigm which includes timbre, texture and sound stage. Two Michael Jackson songs (‘The Lady in My Life’ from 1982 and ‘Scream’ from 1995) are used to: a) demonstrate the value of such a conceptualisation, and b) demonstrate that the model has its limits, as record producers in the 1990s began ignoring the conventions of...

  4. What is Sound?

    OpenAIRE

    Nelson, Peter

    2014-01-01

    What is sound? This question is posed in contradiction to the every-day understanding that sound is a phenomenon apart from us, to be heard, made, shaped and organised. Thinking through the history of computer music, and considering the current configuration of digital communi-cations, sound is reconfigured as a type of network. This network is envisaged as non-hierarchical, in keeping with currents of thought that refuse to prioritise the human in the world. The relationship of sound to musi...

  5. Light and Sound

    CERN Document Server

    Karam, P Andrew

    2010-01-01

    Our world is largely defined by what we see and hear-but our uses for light and sound go far beyond simply seeing a photo or hearing a song. A concentrated beam of light, lasers are powerful tools used in industry, research, and medicine, as well as in everyday electronics like DVD and CD players. Ultrasound, sound emitted at a high frequency, helps create images of a developing baby, cleans teeth, and much more. Light and Sound teaches how light and sound work, how they are used in our day-to-day lives, and how they can be used to learn about the universe at large.

  6. Visual acuity with simulated and real astigmatic defocus.

    Science.gov (United States)

    Ohlendorf, Arne; Tabernero, Juan; Schaeffel, Frank

    2011-05-01

    To compare the effects of "simulated" and "real" spherical and astigmatic defocus on visual acuity (VA). VA was determined with letter charts that were blurred by calculated spherical or astigmatic defocus (simulated defocus) or were seen through spherical or astigmatic trial lenses (real defocus). Defocus was simulated using ZEMAX and the Liou-Brennan eye model. Nine subjects participated [mean age, 27.2 ± 1.8 years; logarithm of the minimum angle of resolution (logMAR), -0.1]. Three different experiments were conducted in which VA was reduced by 20% (logMAR 0.0), 50% (logMAR 0.2), or 75% (logMAR 0.5) by either (1) imposing positive spherical defocus, (2) imposing positive and negative astigmatic defocus in three axes (0, 45, and 90°), and (3) imposing cross-cylinder defocus in the same three axes as in (2). Experiment (1): there were only minor differences in VA with simulated and real positive spherical defocus. Experiment (2): simulated astigmatic defocus reduced VA twice as much as real astigmatic defocus in all tested axes (p < 0.01 in all cases). Experiment (3): simulated cross-cylinder defocus reduced VA much more than real cross-cylinder defocus (p < 0.01 in all cases), similarly for all three tested axes. The visual system appears more tolerant against "real" spherical, astigmatic, and cross-cylinder defocus than against "simulated" blur. Possible reasons could be (1) limitations in the modeling procedures to simulate defocus, (2) higher ocular aberrations, and (3) fluctuations of accommodation. However, the two optical explanations (2) and (3) cannot account for the magnitude of the effect, and (1) was carefully analyzed. It is proposed that something may be special about the visual processing of real astigmatic and cross-cylinder defocus-because they have less effect on VA than simulations predict.

  7. Early Sound Symbolism for Vowel Sounds

    Directory of Open Access Journals (Sweden)

    Ferrinne Spector

    2013-06-01

    Full Text Available Children and adults consistently match some words (e.g., kiki to jagged shapes and other words (e.g., bouba to rounded shapes, providing evidence for non-arbitrary sound–shape mapping. In this study, we investigated the influence of vowels on sound–shape matching in toddlers, using four contrasting pairs of nonsense words differing in vowel sound (/i/ as in feet vs. /o/ as in boat and four rounded–jagged shape pairs. Crucially, we used reduplicated syllables (e.g., kiki vs. koko rather than confounding vowel sound with consonant context and syllable variability (e.g., kiki vs. bouba. Toddlers consistently matched words with /o/ to rounded shapes and words with /i/ to jagged shapes (p < 0.01. The results suggest that there may be naturally biased correspondences between vowel sound and shape.

  8. Development and clinical application of a color pediatric visual acuity chart

    Directory of Open Access Journals (Sweden)

    Shu-Guo Yin

    2014-12-01

    Full Text Available AIM: To introduce a new color pediatric visual acuity chart and its clinical application.METHODS:The color pediatric visual acuity chart was designed based on principle of visual angle. The optotype on the color chart had graphics. The progression rate of optotype size between 2 lines was 10(101/2 and 1.2589. A regular geometric progression of optotype sizes and distribution was employed to arrange 8 lines with 11 optotype on the color chart. The testing distance was 3m. The visual acuity score could be recorded as logarithm of the minimum angle of resolution notation or decimal notation. The reliability of naked distant measurements with this new chart was tested in one eye of 100 children(4 ~6 years oldtaking the Chinese national standard logarithm visual acuity chart standard. RESULTS: The color pediatric visual acuity chart and logarithmic chart controls, visual acuity test results that in the two groups had no significant difference(t=1.2671, P>0.05. Two sets of vision data existed positive correlation(r=0.924, PCONCLUSION:Children are easier to accept used new color pediatric visual acuity chart to inspect vision. New chart is reliability and apply to children's vision screening.

  9. Distinct Circuits for Recovery of Eye Dominance and Acuity in Murine Amblyopia.

    Science.gov (United States)

    Stephany, Céleste-Élise; Ma, Xiaokuang; Dorton, Hilary M; Wu, Jie; Solomon, Alexander M; Frantz, Michael G; Qiu, Shenfeng; McGee, Aaron W

    2018-05-24

    Degrading vision by one eye during a developmental critical period yields enduring deficits in both eye dominance and visual acuity. A predominant model is that "reactivating" ocular dominance (OD) plasticity after the critical period is required to improve acuity in amblyopic adults. However, here we demonstrate that plasticity of eye dominance and acuity are independent and restricted by the nogo-66 receptor (ngr1) in distinct neuronal populations. Ngr1 mutant mice display greater excitatory synaptic input onto both inhibitory and excitatory neurons with restoration of normal vision. Deleting ngr1 in excitatory cortical neurons permits recovery of eye dominance but not acuity. Reciprocally, deleting ngr1 in thalamus is insufficient to rectify eye dominance but yields improvement of acuity to normal. Abolishing ngr1 expression in adult mice also promotes recovery of acuity. Together, these findings challenge the notion that mechanisms for OD plasticity contribute to the alterations in circuitry that restore acuity in amblyopia. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. ANS acuity and mathematics ability in preschoolers from low-income homes: contributions of inhibitory control.

    Science.gov (United States)

    Fuhs, Mary Wagner; McNeil, Nicole M

    2013-01-01

    Recent findings by Libertus, Feigenson, and Halberda (2011) suggest that there is an association between the acuity of young children's approximate number system (ANS) and their mathematics ability before exposure to instruction in formal schooling. The present study examined the generalizability and validity of these findings in a sample of preschoolers from low-income homes. Children attending Head Start (N = 103) completed measures to assess ANS acuity, mathematics ability, receptive vocabulary, and inhibitory control. Results showed only a weak association between ANS acuity and mathematics ability that was reduced to non-significance when controlling for a direct measure of receptive vocabulary. Results also revealed that inhibitory control plays an important role in the relation between ANS acuity and mathematics ability. Specifically, ANS acuity accounted for significant variance in mathematics ability over and above receptive vocabulary, but only for ANS acuity trials in which surface area conflicted with numerosity. Moreover, this association became non-significant when controlling for inhibitory control. These results suggest that early mathematical experiences prior to formal schooling may influence the strength of the association between ANS acuity and mathematics ability and that inhibitory control may drive that association in young children. © 2012 Blackwell Publishing Ltd.

  11. Retention of high tactile acuity throughout the life span in blindness.

    Science.gov (United States)

    Legge, Gordon E; Madison, Cindee; Vaughn, Brenna N; Cheong, Allen M Y; Miller, Joseph C

    2008-11-01

    Previous studies of tactile acuity on the fingertip, using passive touch, have demonstrated an age-related decline in spatial resolution for both sighted and blind subjects. We have reexamined this age dependence with two newly designed tactile-acuity charts that require active exploration of the test symbols. One chart used dot patterns similar to braille, and the other used embossed Landolt rings. Groups of blind braille readers and sighted subjects ranging from 12 to 85 years old were tested in two experiments. We replicated previous findings for sighted subjects by showing an age-related decrease in tactile acuity by nearly 1% per year. Surprisingly, the blind subjects retained high acuity into old age, showing no age-related decline. For the blind subjects, tactile acuity did not correlate with braille reading speed, the amount of daily reading, or the age at which braille was learned. We conclude that when measured with active touch, blind subjects retain high tactile acuity into old age, unlike their aging sighted peers. We propose that blind people's use of active touch in daily activities, not specifically braille reading, results in preservation of tactile acuity across the life span.

  12. Visual acuity and quality of life in dry eye disease: Proceedings of the OCEAN group meeting.

    Science.gov (United States)

    Benítez-Del-Castillo, José; Labetoulle, Marc; Baudouin, Christophe; Rolando, Maurizio; Akova, Yonca A; Aragona, Pasquale; Geerling, Gerd; Merayo-Lloves, Jesús; Messmer, Elisabeth M; Boboridis, Kostas

    2017-04-01

    Dry eye disease (DED) results in tear film instability and hyperosmolarity, inflammation of the ocular surface and, ultimately, visual disturbance that can significantly impact a patient's quality of life. The effects on visual acuity result in difficulties with driving, reading and computer use and negatively impact psychological health. These effects also extend to the workplace, with a loss of productivity and quality of work causing substantial economic losses. The effects of DED and the impact on vision experienced by patients may not be given sufficient importance by ophthalmologists. Functional visual acuity (FVA) is a measure of visual acuity after sustained eye opening without blinking for at least 10 s and mimics the sustained visual acuity of daily life. Measuring dynamic FVA allows the detection of impaired visual function in patients with DED who may display normal conventional visual acuity. There are currently several tests and methods that can be used to measure dynamic visual function: the SSC-350 FVA measurement system, assessment of best-corrected visual acuity decay using the interblink visual acuity decay test, serial measurements of ocular and corneal higher order aberrations, and measurement of dynamic vision quality using the Optical Quality Analysis System. Although the equipment for these methods may be too large or unaffordable for use in clinical practice, FVA testing is an important assessment for DED. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Factors accounting for the 4-year change in acuity in patients between 50 and 80 years.

    Science.gov (United States)

    Koenig, Darren E; Nguyen, Lan Chi; Parker, Katrina E; Applegate, Raymond A

    2013-07-01

    It is well known that acuity slowly decreases in the later decades of life. We wish to determine the extent by which 4-year longitudinal acuity changes can be accounted for by changes in optical quality, or combination of optical quality metrics and of age between 50 and 80 years. High-contrast logMAR acuity, 35 image quality metrics, 4 intraocular scatter metrics, and 4 Lens Opacification Classification System III metrics and entry age were measured on one eye of each of the 148 subjects. Acuity change between baseline and the last visit was regressed against change in each metric for all eyes and a faster changing subset of 50 eyes with a gain or loss of four or more letters. Average change across 148 subjects was a 1.6 ± 4 letter loss (t148 = 4.31, p model for faster changing eyes included change in point spread function entropy, posterior subcapsular cataract, and trefoil and baseline age (sequential r adjusted values of 0.19, 0.27, 0.32, and 0.34, respectively; p = 1.48 × 10 for the full four-factor model). The same variables entered the multiple-regression model for the full 148 data set where most of the acuity measurements were within test-retest error and accounted for less of the variance (r adjusted = 0.15, p = 2.37 × 10). Despite being near noise levels for the measurement of acuity, change in optical quality metrics was the most important factor in eyes that lost or gained four or more letters of acuity. These findings should be generalizable given that our 4-year acuity change is essentially identical to other studies and indicate that these optical quality markers can be used to help identify those on a faster track to an acuity change.

  14. Acuity and case management: a healthy dose of outcomes, part III.

    Science.gov (United States)

    Huber, Diane L; Craig, Kathy

    2007-01-01

    This is the third of a 3-part series presenting 2 effective applications--acuity and dosage--that describe how the business case for case management (CM) can be made. In Part I, dosage and acuity concepts were explained as client need-severity, CM intervention-intensity, and CM activity-dose prescribed by amount, frequency, duration, and breadth of activities. Concepts were presented that related the practice of CM to the use of evidence-based practice (EBP), knowledge, and methods and the development of instruments that measure and score pivotal CM actions. Part I also featured a specific exemplar, the CM Acuity Tool, and described how to use acuity to identify and score the complexity of a CM case. Part II further explained dosage and 2 acuity instruments, the Acuity Tool and AccuDiff. Part III presents linkage to EBP and practical applications. The information contained in the 3-part series applies to all CM practice settings and contains ideas and recommendations useful to CM generalists, specialists, supervisors, and business and outcomes managers. The Acuity Tools Project was developed from frontline CM practice in one large, national telephonic CM company. Dosage: A literature search failed to find research into dosage of a behavioral intervention. The Huber-Hall model was developed and tested in a longitudinal study of CM models in substance abuse treatment and reported in the literature. Acuity: A structured literature search and needs assessment launched the development of the suite of acuity tools. A gap analysis identified that an instrument to assign and measure case acuity specific to CM activities was needed. Clinical experts, quality specialists, and business analysts (n = 7) monitored the development and testing of the tools, acuity concepts, scores, differentials, and their operating principles and evaluated the validity of the acuity tools' content related to CM activities. During the pilot phase of development, interrater reliability testing of

  15. Acuity and case management: a healthy dose of outcomes, part II.

    Science.gov (United States)

    Craig, Kathy; Huber, Diane L

    2007-01-01

    This is the second of a 3-part series presenting 2 effective applications-acuity and dosage-that describe how the business case for case management (CM) can be made. In Part I, dosage and acuity concepts were explained as client need-severity, CM intervention-intensity, and CM activity-dose prescribed by amount, frequency, duration, and breadth of activities. Part I also featured a specific exemplar, the CM Acuity Tool, and described how to use acuity to identify and score the complexity of a CM case. Appropriate dosage prescription of CM activity was discussed. Part II further explains dosage and presents two acuity instruments, the Acuity Tool and AccuDiff. Details are provided that show how these applications produce opportunities for better communication about CM cases and for more accurate measurement of the right content that genuinely reflects the essentials of CM practice. The information contained in the 3-part series applies to all CM practice settings and contains ideas and recommendations useful to CM generalists, specialists, and supervisors, plus business and outcomes managers. The Acuity Tools Project was developed from frontline CM practice in one large, national telephonic CM company. Dosage: A literature search failed to find research into dosage of a behavioral intervention. The Huber-Hall model was developed and tested in a longitudinal study of CM models in substance abuse treatment and reported in the literature. Acuity: A structured literature search and needs assessment launched the development of the suite of acuity tools. A gap analysis identified that an instrument to assign and measure case acuity specific to CM activities was needed. Clinical experts, quality specialists, and business analysts (n = 7) monitored the development and testing of the tools, acuity concepts, scores, differentials, and their operating principles and evaluated the validity of the Acuity Tools' content related to CM activities. During the pilot phase of

  16. InfoSound

    DEFF Research Database (Denmark)

    Sonnenwald, Diane H.; Gopinath, B.; Haberman, Gary O.

    1990-01-01

    The authors explore ways to enhance users' comprehension of complex applications using music and sound effects to present application-program events that are difficult to detect visually. A prototype system, Infosound, allows developers to create and store musical sequences and sound effects with...

  17. Breaking the Sound Barrier

    Science.gov (United States)

    Brown, Tom; Boehringer, Kim

    2007-01-01

    Students in a fourth-grade class participated in a series of dynamic sound learning centers followed by a dramatic capstone event--an exploration of the amazing Trashcan Whoosh Waves. It's a notoriously difficult subject to teach, but this hands-on, exploratory approach ignited student interest in sound, promoted language acquisition, and built…

  18. Sound propagation in cities

    NARCIS (Netherlands)

    Salomons, E.; Polinder, H.; Lohman, W.; Zhou, H.; Borst, H.

    2009-01-01

    A new engineering model for sound propagation in cities is presented. The model is based on numerical and experimental studies of sound propagation between street canyons. Multiple reflections in the source canyon and the receiver canyon are taken into account in an efficient way, while weak

  19. OMNIDIRECTIONAL SOUND SOURCE

    DEFF Research Database (Denmark)

    1996-01-01

    A sound source comprising a loudspeaker (6) and a hollow coupler (4) with an open inlet which communicates with and is closed by the loudspeaker (6) and an open outlet, said coupler (4) comprising rigid walls which cannot respond to the sound pressures produced by the loudspeaker (6). According...

  20. Hamiltonian Algorithm Sound Synthesis

    OpenAIRE

    大矢, 健一

    2013-01-01

    Hamiltonian Algorithm (HA) is an algorithm for searching solutions is optimization problems. This paper introduces a sound synthesis technique using Hamiltonian Algorithm and shows a simple example. "Hamiltonian Algorithm Sound Synthesis" uses phase transition effect in HA. Because of this transition effect, totally new waveforms are produced.

  1. Poetry Pages. Sound Effects.

    Science.gov (United States)

    Fina, Allan de

    1992-01-01

    Explains how elementary teachers can help students understand onomatopoeia, suggesting that they define onomatopoeia, share examples of it, read poems and have students discuss onomatopoeic words, act out common household sounds, write about sound effects, and create choral readings of onomatopoeic poems. Two appropriate poems are included. (SM)

  2. Exploring Noise: Sound Pollution.

    Science.gov (United States)

    Rillo, Thomas J.

    1979-01-01

    Part one of a three-part series about noise pollution and its effects on humans. This section presents the background information for teachers who are preparing a unit on sound. The next issues will offer learning activities for measuring the effects of sound and some references. (SA)

  3. Effects of dynamic-range compression on temporal acuity

    DEFF Research Database (Denmark)

    Wiinberg, Alan; Jepsen, Morten Løve; Epp, Bastian

    2016-01-01

    Some of the challenges that hearing-aid listeners experience with speech perception in complex acoustic environments may originate from limitations in the temporal processing of sounds. To systematically investigate the influence of hearing impairment and hearing-aid signal processing on temporal...... processing, temporal modulation transfer functions (TMTFs) and “supra-threshold” modulation-depth discrimination (MDD) thresholds were obtained in normal-hearing (NH) and hearing-impaired (HI) listeners with and without wide-dynamic range compression (WDRC). The TMTFs were obtained using tonal carriers of 1...... with the physical compression of the modulation depth due to the WDRC. Indications of reduced temporal resolution in the HI listeners were observed in the TMTF patterns for the 5 kHz carrier. Significantly higher MDD thresholds were found for the HI group relative to the NH group. No relationship was found between...

  4. Waveform analysis of sound

    CERN Document Server

    Tohyama, Mikio

    2015-01-01

    What is this sound? What does that sound indicate? These are two questions frequently heard in daily conversation. Sound results from the vibrations of elastic media and in daily life provides informative signals of events happening in the surrounding environment. In interpreting auditory sensations, the human ear seems particularly good at extracting the signal signatures from sound waves. Although exploring auditory processing schemes may be beyond our capabilities, source signature analysis is a very attractive area in which signal-processing schemes can be developed using mathematical expressions. This book is inspired by such processing schemes and is oriented to signature analysis of waveforms. Most of the examples in the book are taken from data of sound and vibrations; however, the methods and theories are mostly formulated using mathematical expressions rather than by acoustical interpretation. This book might therefore be attractive and informative for scientists, engineers, researchers, and graduat...

  5. Sound classification of dwellings

    DEFF Research Database (Denmark)

    Rasmussen, Birgit

    2012-01-01

    National schemes for sound classification of dwellings exist in more than ten countries in Europe, typically published as national standards. The schemes define quality classes reflecting different levels of acoustical comfort. Main criteria concern airborne and impact sound insulation between...... dwellings, facade sound insulation and installation noise. The schemes have been developed, implemented and revised gradually since the early 1990s. However, due to lack of coordination between countries, there are significant discrepancies, and new standards and revisions continue to increase the diversity...... is needed, and a European COST Action TU0901 "Integrating and Harmonizing Sound Insulation Aspects in Sustainable Urban Housing Constructions", has been established and runs 2009-2013, one of the main objectives being to prepare a proposal for a European sound classification scheme with a number of quality...

  6. Higher-order aberrations and visual acuity after LASEK.

    Science.gov (United States)

    Urgancioglu, Berrak; Bilgihan, Kamil; Ozturk, Sertac

    2008-08-01

    To determine ocular higher-order aberrations (HOAs) in eyes with supernormal vision after myopic astigmatic laser subepithelial keratomileusis (LASEK) and to compare the findings with those in eyes with natural supernormal vision. Ocular HOAs were measured after LASEK in 20 eyes of 12 myopic astigmatic patients with postoperative uncorrected visual acuity (UCVA) of >20/16 (group 1). Patients who were included in the study had no visual symptoms like glare, halo or double vision. The measurements were taken 8.3 +/- 3 months after LASEK surgery. In group 2 ocular HOAs were examined in 20 eyes of 10 subjects with natural UCVA of >20/16 as a control. Measurements were taken across a pupil with a diameter of 4.0 mm and 6.0 mm. Root-mean-square (RMS) values of HOAs, Z(3)-1, Z(3)1, Z(4)0, Z(5)-1, Z(5)1 and Z(6)0 were analyzed. The mean RMS values for each order were higher in group 1 when compared with group 2 at 4.0 mm and 6.0 mm pupil diameters. There was no statistically significant difference between groups in spherical and coma aberrations (P > 0.05). Mean RMS values for total HOAs were 0.187 +/- 0.09 microm at 4.0 mm and 0.438 +/- 0.178 microm at 6.0 mm pupil in group 1 and 0.120 +/- 0.049 microm at 4.0 mm and 0.344 +/- 0.083 microm at 6.0 mm pupil in group 2. The difference between groups in total HOAs was statistically significant at 4.0 mm and 6.0 mm pupil diameters (P < 0.05). Ocular HOAs exist in eyes with supernormal vision. After LASEK, the amount of HOAs of the eye increases under both mesopic and photopic conditions. However the amount of HOA increase does not seem to be consistent with visual symptoms.

  7. Revealing Detail along the Visual Hierarchy: Neural Clustering Preserves Acuity from V1 to V4.

    Science.gov (United States)

    Lu, Yiliang; Yin, Jiapeng; Chen, Zheyuan; Gong, Hongliang; Liu, Ye; Qian, Liling; Li, Xiaohong; Liu, Rui; Andolina, Ian Max; Wang, Wei

    2018-04-18

    How primates perceive objects along with their detailed features remains a mystery. This ability to make fine visual discriminations depends upon a high-acuity analysis of spatial frequency (SF) along the visual hierarchy from V1 to inferotemporal cortex. By studying the transformation of SF across macaque parafoveal V1, V2, and V4, we discovered SF-selective functional domains in V4 encoding higher SFs up to 12 cycles/°. These intermittent higher-SF-selective domains, surrounded by domains encoding lower SFs, violate the inverse relationship between SF preference and retinal eccentricity. The neural activities of higher- and lower-SF domains correspond to local and global features, respectively, of the same stimuli. Neural response latencies in high-SF domains are around 10 ms later than in low-SF domains, consistent with the coarse-to-fine nature of perception. Thus, our finding of preserved resolution from V1 into V4, separated both spatially and temporally, may serve as a connecting link for detailed object representation. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. [Measuring contrast sensitivity using visual acuity tests in retinal and optic nerve diseases].

    Science.gov (United States)

    Sommer, E; Marré, E; Mierdel, P

    1990-01-01

    The luminance contrast needed to discern various test types was measured with monochromatic and achromatic light to detect discrete functional deficiencies of the retina and optic nerve in cases of normal visual acuity. Landolt rings corresponding to visual acuity levels from 0.04 to 1.0 were used as test types. A significant increase in the necessary minimum contrast was detectable with blue test light on large Landolt rings in patients with diabetic retinopathy, ocular hypertension and glaucoma and with green or yellow test light on medium-sized and small Landolt rings in patients with central serous chorioidopathy and optic atrophy. The additional contrast needed to reach the maximum visual acuity amounts to 14-100% compared with normal visual acuity, depending on the color of the test light and the diagnosis. The amount of contrast needed is greatest in retinal diseases, and it is therefore possible to a certain extent to distinguish these from diseases of the optic nerve.

  9. The sound manifesto

    Science.gov (United States)

    O'Donnell, Michael J.; Bisnovatyi, Ilia

    2000-11-01

    Computing practice today depends on visual output to drive almost all user interaction. Other senses, such as audition, may be totally neglected, or used tangentially, or used in highly restricted specialized ways. We have excellent audio rendering through D-A conversion, but we lack rich general facilities for modeling and manipulating sound comparable in quality and flexibility to graphics. We need coordinated research in several disciplines to improve the use of sound as an interactive information channel. Incremental and separate improvements in synthesis, analysis, speech processing, audiology, acoustics, music, etc. will not alone produce the radical progress that we seek in sonic practice. We also need to create a new central topic of study in digital audio research. The new topic will assimilate the contributions of different disciplines on a common foundation. The key central concept that we lack is sound as a general-purpose information channel. We must investigate the structure of this information channel, which is driven by the cooperative development of auditory perception and physical sound production. Particular audible encodings, such as speech and music, illuminate sonic information by example, but they are no more sufficient for a characterization than typography is sufficient for characterization of visual information. To develop this new conceptual topic of sonic information structure, we need to integrate insights from a number of different disciplines that deal with sound. In particular, we need to coordinate central and foundational studies of the representational models of sound with specific applications that illuminate the good and bad qualities of these models. Each natural or artificial process that generates informative sound, and each perceptual mechanism that derives information from sound, will teach us something about the right structure to attribute to the sound itself. The new Sound topic will combine the work of computer

  10. Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.

    Science.gov (United States)

    Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara

    2017-01-01

    Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.

  11. Managing the impact of growing low-acuity demand on ambulance services

    OpenAIRE

    KATHRYN JEAN EASTWOOD

    2018-01-01

    Increasing demand for emergency ambulances places a substantial burden on ambulance services. Many cases are low-acuity, having no urgent clinical need for paramedic treatment. Ambulance Victoria implemented a secondary telephone triage services to divert low-acuity cases away from emergency ambulances to more appropriate care. This research found this ‘Referral Service’ has had a substantial impact upon emergency operations, referring over 70% of the cases it managed away from emergency am...

  12. The effect of state medicaid case-mix payment on nursing home resident acuity.

    Science.gov (United States)

    Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Mor, Vincent

    2006-08-01

    To examine the relationship between Medicaid case-mix payment and nursing home resident acuity. Longitudinal Minimum Data Set (MDS) resident assessments from 1999 to 2002 and Online Survey Certification and Reporting (OSCAR) data from 1996 to 2002, for all freestanding nursing homes in the 48 contiguous U.S. states. We used a facility fixed-effects model to examine the effect of introducing state case-mix payment on changes in nursing home case-mix acuity. Facility acuity was measured by aggregating the nursing case-mix index (NCMI) from the MDS using the Resource Utilization Group (Version III) resident classification system, separately for new admits and long-stay residents, and by an OSCAR-derived index combining a range of activity of daily living dependencies and special treatment measures. We followed facilities over the study period to create a longitudinal data file based on the MDS and OSCAR, respectively, and linked facilities with longitudinal data on state case-mix payment policies for the same period. Across three acuity measures and two data sources, we found that states shifting to case-mix payment increased nursing home acuity levels over the study period. Specifically, we observed a 2.5 percent increase in the average acuity of new admits and a 1.3 to 1.4 percent increase in the acuity of long-stay residents, following the introduction of case-mix payment. The adoption of case-mix payment increased access to care for higher acuity Medicaid residents.

  13. EXAMINATION OF THE VISUAL ACUITY ON THE LCD OPTOTYPE WITH WHOLE-LINE AND INTERPOLATION METHOD

    OpenAIRE

    Zajíček Tomáš; Veselý Petr; Veselý Petr; Synek Svatopluk; Synek Svatopluk

    2012-01-01

    The goal of this work is to show the possibility of us using the LCD optotype in common optometrist practice. Furthermore two commonly used methods for measuring visual acuity will be compared. 69 respondents were used for the measurements. The respondents were divided into two groups according to the measured LCD optotype. The visual acuity was measured using the whole-line method on modified Snellen charts as well as the interpolation method on ETDRS charts. Measurements were taken on the S...

  14. Crowded letter and crowded picture logMAR acuity in children with amblyopia: a quantitative comparison.

    Science.gov (United States)

    O'Boyle, Cathy; Chen, Sean I; Little, Julie-Anne

    2017-04-01

    Clinically, picture acuity tests are thought to overestimate visual acuity (VA) compared with letter tests, but this has not been systematically investigated in children with amblyopia. This study compared VA measurements with the LogMAR Crowded Kay Picture test to the LogMAR Crowded Keeler Letter acuity test in a group of young children with amblyopia. 58 children (34 male) with amblyopia (22 anisometropic, 18 strabismic and 18 with both strabismic/anisometropic amblyopia) aged 4-6 years (mean=68.7, range=48-83 months) underwent VA measurements. VA chart testing order was randomised, but the amblyopic eye was tested before the fellow eye. All participants wore up-to-date refractive correction. The Kay Picture test significantly overestimated VA by 0.098 logMAR (95% limits of agreement (LOA), 0.13) in the amblyopic eye and 0.088 logMAR (95% LOA, 0.13) in the fellow eye, respectively (pocclusion therapy, refractive correction or type of amblyopia on VA results (p>0.23). For both the amblyopic and fellow eyes, Bland-Altman plots demonstrated a systematic and predictable difference between Kay Picture and Keeler Letter charts across the range of acuities tested (Keeler acuity: amblyopic eye 0.75 to -0.05 logMAR; fellow eye 0.45 to -0.15 logMAR). Linear regression analysis (pamblyopia. Due to the predictable difference found between both crowded logMAR acuity tests, it is reasonable to adjust Kay Picture acuity thresholds by +0.10 logMAR to compute expected Keeler Letter acuity scores. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Proprioceptive acuity into knee hypermobile range in children with Joint Hypermobility Syndrome

    OpenAIRE

    Pacey, Verity; Adams, Roger D; Tofts, Louise; Munns, Craig F; Nicholson, Leslie L

    2014-01-01

    Background Children with Joint Hypermobility Syndrome (JHS) have reduced knee joint proprioceptive acuity compared to peers. Altered proprioception at end of range in individuals with JHS is hypothesised to contribute to recurrent joint injuries and instability. This study aims to provide the first objective comparison of functional knee joint proprioceptive acuity in hyperextension range compared to early flexion range in children with JHS. Methods Active, weight-bearing knee joint proprioce...

  16. Lrit1, a Retinal Transmembrane Protein, Regulates Selective Synapse Formation in Cone Photoreceptor Cells and Visual Acuity

    Directory of Open Access Journals (Sweden)

    Akiko Ueno

    2018-03-01

    Full Text Available Summary: In the vertebrate retina, cone photoreceptors play crucial roles in photopic vision by transmitting light-evoked signals to ON- and/or OFF-bipolar cells. However, the mechanisms underlying selective synapse formation in the cone photoreceptor pathway remain poorly understood. Here, we found that Lrit1, a leucine-rich transmembrane protein, localizes to the photoreceptor synaptic terminal and regulates the synaptic connection between cone photoreceptors and cone ON-bipolar cells. Lrit1-deficient retinas exhibit an aberrant morphology of cone photoreceptor pedicles, as well as an impairment of signal transmission from cone photoreceptors to cone ON-bipolar cells. Furthermore, we demonstrated that Lrit1 interacts with Frmpd2, a photoreceptor scaffold protein, and with mGluR6, an ON-bipolar cell-specific glutamate receptor. Additionally, Lrit1-null mice showed visual acuity impairments in their optokinetic responses. These results suggest that the Frmpd2-Lrit1-mGluR6 axis regulates selective synapse formation in cone photoreceptors and is essential for normal visual function. : Ueno et al. finds that Lrit1 plays an important role in regulating the synaptic connection between cone photoreceptors and cone ON-bipolar cells. The Frmpd2-Lrit1-mGluR6 axis is crucial for selective synapse formation in cone photoreceptors and for development of normal visual function. Keywords: retina, circuit, synapse formation, cone photoreceptor cell, ON-bipolar cell, visual acuity

  17. Influence of Passive Joint Stiffness on Proprioceptive Acuity in Individuals With Functional Instability of the Ankle.

    Science.gov (United States)

    Marinho, Hellen Veloso Rocha; Amaral, Giovanna Mendes; de Souza Moreira, Bruno; Araújo, Vanessa Lara; Souza, Thales Rezende; Ocarino, Juliana Melo; da Fonseca, Sérgio Teixeira

    2017-12-01

    Study Design Controlled laboratory study, cross-sectional. Background Deficits in ankle proprioceptive acuity have been reported in persons with functional instability of the ankle. Passive stiffness has been proposed as a possible mechanism underlying proprioceptive acuity. Objective To compare proprioceptive acuity and passive ankle stiffness in persons with and without functional ankle instability, and to assess the influence of passive joint stiffness on proprioceptive acuity in persons with functional ankle instability. Methods A sample of 18 subjects with and 18 without complaints of functional ankle instability following lateral ankle sprain participated. An isokinetic dynamometer was used to compare motion perception threshold, passive position sense, and passive ankle stiffness between groups. To evaluate the influence of passive stiffness on proprioceptive acuity, individuals in the lateral functional ankle instability group were divided into 2 subgroups: "high" and "low" passive ankle stiffness. Results The functional ankle instability group exhibited increased motion perception threshold when compared with the corresponding limb of the control group. Between-group differences were not found for passive position sense and passive ankle stiffness. Those in the functional ankle instability group with higher passive ankle stiffness had smaller motion perception thresholds than those with lower passive ankle stiffness. Conclusion Unlike motion perception threshold, passive position sense is not affected by the presence of functional ankle instability. Passive ankle stiffness appears to influence proprioceptive acuity in persons with functional ankle instability. J Orthop Sports Phys Ther 2017;47(12):899-905. Epub 7 Oct 2017. doi:10.2519/jospt.2017.7030.

  18. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    Science.gov (United States)

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  19. Tactile acuity and lumbopelvic motor control in patients with back pain and healthy controls.

    Science.gov (United States)

    Luomajoki, H; Moseley, G L

    2011-04-01

    Voluntary lumbopelvic control is compromised in patients with back pain. Loss of proprioceptive acuity is one contributor to decreased control. Several reasons for decreased proprioceptive acuity have been proposed, but the integrity of cortical body maps has been overlooked. We investigated whether tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to lumbopelvic control in people with back pain. Forty-five patients with back pain and 45 age- and sex-matched healthy controls participated in this cross-sectional study. Tactile acuity at the back was assessed using two-point discrimination (TPD) threshold in vertical and horizontal directions. Voluntary motor control was assessed using an established battery of clinical tests. Patients performed worse on the voluntary lumbopelvic tasks than healthy controls did (p<0.001). TPD threshold was larger in patients (mean (SD)=61 (13) mm) than in healthy controls (44 (10) mm). Moreover, larger TPD threshold was positively related to worse performance on the voluntary lumbopelvic tasks (Pearson's r=0.49; p<0.001). Tactile acuity, a clear clinical signature of primary sensory cortex organisation, relates to voluntary lumbopelvic control. This relationship raises the possibility that the former contributes to the latter, in which case training tactile acuity may aid recovery and assist in achieving normal motor performance after back injury.

  20. Digitizing a sound archive

    DEFF Research Database (Denmark)

    Cone, Louise

    2017-01-01

    Danish and international artists. His methodology left us with a large collection of unique and inspirational time-based media sound artworks that have, until very recently, been inaccessible. Existing on an array of different media formats, such as open reel tapes, 8-track and 4 track cassettes, VHS......In 1990 an artist by the name of William Louis Sørensen was hired by the National Gallery of Denmark to collect important works of art – made from sound. His job was to acquire sound art, but also recordings that captured rare artistic occurrences, music, performances and happenings from both...

  1. Sounds of Web Advertising

    DEFF Research Database (Denmark)

    Jessen, Iben Bredahl; Graakjær, Nicolai Jørgensgaard

    2010-01-01

    Sound seems to be a neglected issue in the study of web ads. Web advertising is predominantly regarded as visual phenomena–commercial messages, as for instance banner ads that we watch, read, and eventually click on–but only rarely as something that we listen to. The present chapter presents...... an overview of the auditory dimensions in web advertising: Which kinds of sounds do we hear in web ads? What are the conditions and functions of sound in web ads? Moreover, the chapter proposes a theoretical framework in order to analyse the communicative functions of sound in web advertising. The main...... argument is that an understanding of the auditory dimensions in web advertising must include a reflection on the hypertextual settings of the web ad as well as a perspective on how users engage with web content....

  2. Sound Art Situations

    DEFF Research Database (Denmark)

    Krogh Groth, Sanne; Samson, Kristine

    2017-01-01

    and combine theories from several fields. Aspects of sound art studies, performance studies and contemporary art studies are presented in order to theoretically explore the very diverse dimensions of the two sound art pieces: Visual, auditory, performative, social, spatial and durational dimensions become......This article is an analysis of two sound art performances that took place June 2015 in outdoor public spaces in the social housing area Urbanplanen in Copenhagen, Denmark. The two performances were On the production of a poor acoustics by Brandon LaBelle and Green Interactive Biofeedback...... Environments (GIBE) by Jeremy Woodruff. In order to investigate the complex situation that arises when sound art is staged in such contexts, the authors of this article suggest exploring the events through approaching them as ‘situations’ (Doherty 2009). With this approach it becomes possible to engage...

  3. Sound as Popular Culture

    DEFF Research Database (Denmark)

    The wide-ranging texts in this book take as their premise the idea that sound is a subject through which popular culture can be analyzed in an innovative way. From an infant’s gurgles over a baby monitor to the roar of the crowd in a stadium to the sub-bass frequencies produced by sound systems...... in the disco era, sound—not necessarily aestheticized as music—is inextricably part of the many domains of popular culture. Expanding the view taken by many scholars of cultural studies, the contributors consider cultural practices concerning sound not merely as semiotic or signifying processes but as material......, physical, perceptual, and sensory processes that integrate a multitude of cultural traditions and forms of knowledge. The chapters discuss conceptual issues as well as terminologies and research methods; analyze historical and contemporary case studies of listening in various sound cultures; and consider...

  4. It sounds good!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Both the atmosphere and we ourselves are hit by hundreds of particles every second and yet nobody has ever heard a sound coming from these processes. Like cosmic rays, particles interacting inside the detectors at the LHC do not make any noise…unless you've decided to use the ‘sonification’ technique, in which case you might even hear the Higgs boson sound like music. Screenshot of the first page of the "LHC sound" site. A group of particle physicists, composers, software developers and artists recently got involved in the ‘LHC sound’ project to make the particles at the LHC produce music. Yes…music! The ‘sonification’ technique converts data into sound. “In this way, if you implement the right software you can get really nice music out of the particle tracks”, says Lily Asquith, a member of the ATLAS collaboration and one of the initiators of the project. The ‘LHC...

  5. Sound Visualization and Holography

    Science.gov (United States)

    Kock, Winston E.

    1975-01-01

    Describes liquid surface holograms including their application to medicine. Discusses interference and diffraction phenomena using sound wave scanning techniques. Compares focussing by zone plate to holographic image development. (GH)

  6. Improvement of visual acuity by refraction in a low-vision population.

    Science.gov (United States)

    Sunness, Janet S; El Annan, Jaafar

    2010-07-01

    Refraction often may be overlooked in low-vision patients, because the main cause of vision decrease is not refractive, but rather is the result of underlying ocular disease. This retrospective study was carried out to determine how frequently and to what extent visual acuity is improved by refraction in a low-vision population. Cross-sectional study. Seven hundred thirty-nine low-vision patients seen for the first time. A database with all new low-vision patients seen from November 2005 through June 2008 recorded presenting visual acuity using an Early Treatment Diabetic Retinopathy Study chart; it also recorded the best-corrected visual acuity (BCVA) if it was 2 lines or more better than the presenting visual acuity. Retinoscopy was carried out on all patients, followed by manifest refraction. Improvement in visual acuity. Median presenting acuity was 20/80(-2) (interquartile range, 20/50-20/200). There was an improvement of 2 lines or more of visual acuity in 81 patients (11% of all patients), with 22 patients (3% of all patients) improving by 4 lines or more. There was no significant difference in age or in presenting visual acuity between the group that did not improve by refraction and the group that did improve. When stratified by diagnosis, the only 2 diagnoses with a significantly higher rate of improvement than the age-related macular degeneration group were myopic degeneration and progressive myopia (odds ratio, 4.8; 95% confidence interval [CI], 3.0-6.7) and status post-retinal detachment (odds ratio, 7.1; 95% CI, 5.2-9.0). For 5 patients (6% of those with improvement), the eye that was 1 line or more worse than the fellow eye at presentation became the eye that was 1 line or more better than the fellow eye after refraction. A significant improvement in visual acuity was attained by refraction in 11% of the new low-vision patients. Improvement was seen across diagnoses and the range of presenting visual acuity. The worse-seeing eye at presentation may

  7. March 1964 Prince William Sound, USA Images

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Prince William Sound magnitude 9.2 Mw earthquake on March 28, 1964 at 03:36 GMT (March 27 at 5:36 pm local time), was the largest U.S. earthquake ever recorded...

  8. Sound Stuff? Naïve materialism in middle-school students' conceptions of sound

    Science.gov (United States)

    Eshach, Haim; Schwartz, Judah L.

    2006-06-01

    Few studies have dealt with students’ preconceptions of sounds. The current research employs Reiner et al. (2000) substance schema to reveal new insights about students’ difficulties in understanding this fundamental topic. It aims not only to detect whether the substance schema is present in middle school students’ thinking, but also examines how students use the schema’s properties. It asks, moreover, whether the substance schema properties are used as islands of local consistency or whether one can identify more global coherent consistencies among the properties that the students use to explain the sound phenomena. In-depth standardized open-ended interviews were conducted with ten middle school students. Consistent with the substance schema, sound was perceived by our participants as being pushable, frictional, containable, or transitional. However, sound was also viewed as a substance different from the ordinary with respect to its stability, corpuscular nature, additive properties, and inertial characteristics. In other words, students’ conceptions of sound do not seem to fit Reiner et al.’s schema in all respects. Our results also indicate that students’ conceptualization of sound lack internal consistency. Analyzing our results with respect to local and global coherence, we found students’ conception of sound is close to diSessa’s “loosely connected, fragmented collection of ideas.” The notion that sound is perceived only as a “sort of a material,” we believe, requires some revision of the substance schema as it applies to sound. The article closes with a discussion concerning the implications of the results for instruction.

  9. The upper lithostratigraphic unit of ANDRILL AND-2A core (Southern McMurdo Sound, Antarctica): local Pleistocene volcanic sources, paleoenvironmental implications and subsidence in the southern Victoria Land Basin

    Science.gov (United States)

    Del Carlo, P.; Panter, K. S.; Bassett, K. N.; Bracciali, L.; di Vincenzo, G.; Rocchi, S.

    2009-12-01

    We report results from the study of the uppermost 37 meters of the Southern McMurdo Sound (SMS) AND-2A drillcore, corresponding to the lithostratigraphic unit 1 (LSU 1), the most volcanogenic unit within the core. Nearly all of LSU 1 consists of volcanic breccia and sandstone that is a mixture of near primary volcanic material dominated by lava and vitric clasts with minor exotic material derived from distal basement sources. Lava clasts and glass are mafic and range from strongly alkaline (basanite, tephrite) to moderately alkaline (alkali basalt, hawaiite) compositions that are similar to nearby land deposits. 40Ar-39Ar laser step-heating analyses on groundmass separated from lava clasts yield Pleistocene ages (692±38 and 793±63, ±2σ internal errors). Volcanoes of the Dailey Island group, located ~13 km SW of the drillsite, are a possible source for the volcanic materials based on their close proximity, similar composition and age. A basanite lava flow on Juergens Island yields a comparable Pleistocene age of 775±22 ka. Yet there is evidence to suggest that the volcanic source is much closer to the drillsite and that the sediments were deposited in much shallower water relative to the present-day water depth of 384 mbsl. Evidence for local volcanic activity is based in part on the common occurrence of delicate vitriclasts (e.g. glass shards and Pele’s hair) and a minimally reworked ~2 meter thick monomict breccia that is interpreted to have formed by autobrecciating lava. In addition, conical-shaped seamounts and high frequency magnetic anomalies encompass the drillsite and extend south including the volcanoes of the Dailey Islands. Sedimentary features and structures indicate shallow water sedimentation for the whole of LSU 1. Rippled asymmetric cross-laminated sands and hummocky cross-stratification occur intermittently throughout LSU 1 and indicate water depths shallower than 100 meters. The occurrence of ooliths and layers containing siderite and Fe

  10. Acuity-adaptable nursing care: exploring its place in designing the future patient room.

    Science.gov (United States)

    Kwan, Melissa A

    2011-01-01

    To substantiate the anticipated benefits of the original acuity-adaptable care delivery model as defined by innovator Ann Hendrich. In today's conveyor belt approach to healthcare, upon admission and through discharge, patients are commonly transferred based on changing acuity needs. Wasted time and money and inefficiencies in hospital operations often result-in addition to jeopardizing patient safety. In the last decade, a handful of hospitals pioneered the implementation of the acuity-adaptable care delivery model. Built on the concept of eliminating patient transfers, the projected outcomes of acuity-adaptable units-decreased average lengths of stay, increased patient safety and satisfaction, and increased nurses' satisfaction from reduced walking distances-make a good case for a model patient room. Although some hospitals experienced the projected benefits of the acuity-adaptable care delivery model, sustaining the outcomes proved to be difficult; hence, the original definition of acuity-adaptable units has not fared well. Variations on the original concept demonstrate that eliminating patient transfers has not been completely abandoned in healthcare redesign and construction initiatives. Terms such as flex-up, flex-down, universal room, and single-stay unit have since emerged. These variations convolute the search for empirical evidence to support the anticipated benefits of the original concept. To determine the future of this concept and its variants, a significant amount of outcome data must be generated by piloting the concept in different hospital settings. As further refinements and adjustments to the concept emerge, the acuity-adaptable room may find a place in future hospitals.

  11. Effect of Target Location on Dynamic Visual Acuity During Passive Horizontal Rotation

    Science.gov (United States)

    Appelbaum, Meghan; DeDios, Yiri; Kulecz, Walter; Peters, Brian; Wood, Scott

    2010-01-01

    The vestibulo-ocular reflex (VOR) generates eye rotation to compensate for potential retinal slip in the specific plane of head movement. Dynamic visual acuity (DVA) has been utilized as a functional measure of the VOR. The purpose of this study was to examine changes in accuracy and reaction time when performing a DVA task with targets offset from the plane of rotation, e.g. offset vertically during horizontal rotation. Visual acuity was measured in 12 healthy subjects as they moved a hand-held joystick to indicate the orientation of a computer-generated Landolt C "as quickly and accurately as possible." Acuity thresholds were established with optotypes presented centrally on a wall-mounted LCD screen at 1.3 m distance, first without motion (static condition) and then while oscillating at 0.8 Hz (DVA, peak velocity 60 deg/s). The effect of target location was then measured during horizontal rotation with the optotypes randomly presented in one of nine different locations on the screen (offset up to 10 deg). The optotype size (logMar 0, 0.2 or 0.4, corresponding to Snellen range 20/20 to 20/50) and presentation duration (150, 300 and 450 ms) were counter-balanced across five trials, each utilizing horizontal rotation at 0.8 Hz. Dynamic acuity was reduced relative to static acuity in 7 of 12 subjects by one step size. During the random target trials, both accuracy and reaction time improved proportional to optotype size. Accuracy and reaction time also improved between 150 ms and 300 ms presentation durations. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements when acquiring vertical targets. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of motion. Both reaction time and accuracy are functionally relevant DVA parameters of VOR function.

  12. Visual Acuity Testing: Feedback Affects Neither Outcome nor Reproducibility, but Leaves Participants Happier.

    Science.gov (United States)

    Bach, Michael; Schäfer, Kerstin

    2016-01-01

    Assessment of visual acuity is a well standardized procedure at least for expert opinions and clinical trials. It is often recommended not giving patients feedback on the correctness of their responses. As this viewpoint has not been quantitatively examined so far, we quantitatively assessed possible effects of feedback on visual acuity testing. In 40 normal participants we presented Landolt Cs in 8 orientations using the automated Freiburg Acuity Test (FrACT, feedback was provided in 2 x 4 conditions: (A) no feedback, (B) acoustic signals indicating correctness, (C)visual indication of correct orientation, and (D) a combination of (B) and (C). After each run the participants judged comfort. Main outcome measures were absolute visual acuity (logMAR), its test-retest agreement (limits of agreement) and participants' comfort estimates on a 5-step symmetric Likert scale. Feedback influenced acuity outcome significantly (p = 0.02), but with a tiny effect size: 0.02 logMAR poorer acuity for (D) compared to (A), even weaker effects for (B) and (C). Test-retest agreement was high (limits of agreement: ± 1.0 lines) and did not depend on feedback (p>0.5). The comfort ranking clearly differed, by 2 steps on the Likert scale: the condition (A)-no feedback-was on average "slightly uncomfortable", the other three conditions were "slightly comfortable" (pFeedback affected neither reproducibility nor the acuity outcome to any relevant extent. The participants, however, reported markedly greater comfort with any kind of feedback. We conclude that systematic feedback (as implemented in FrACT) offers nothing but advantages for routine use.

  13. Visual Acuity does not Moderate Effect Sizes of Higher-Level Cognitive Tasks

    Science.gov (United States)

    Houston, James R.; Bennett, Ilana J.; Allen, Philip A.; Madden, David J.

    2016-01-01

    Background Declining visual capacities in older adults have been posited as a driving force behind adult age differences in higher-order cognitive functions (e.g., the “common cause” hypothesis of Lindenberger & Baltes, 1994). McGowan, Patterson and Jordan (2013) also found that a surprisingly large number of published cognitive aging studies failed to include adequate measures of visual acuity. However, a recent meta-analysis of three studies (LaFleur & Salthouse, 2014) failed to find evidence that visual acuity moderated or mediated age differences in higher-level cognitive processes. In order to provide a more extensive test of whether visual acuity moderates age differences in higher-level cognitive processes, we conducted a more extensive meta-analysis of topic. Methods Using results from 456 studies, we calculated effect sizes for the main effect of age across four cognitive domains (attention, executive function, memory, and perception/language) separately for five levels of visual acuity criteria (no criteria, undisclosed criteria, self-reported acuity, 20/80-20/31, and 20/30 or better). Results As expected, age had a significant effect on each cognitive domain. However, these age effects did not further differ as a function of visual acuity criteria. Conclusion The current meta-analytic, cross-sectional results suggest that visual acuity is not significantly related to age group differences in higher-level cognitive performance—thereby replicating LaFleur and Salthouse (2014). Further efforts are needed to determine whether other measures of visual functioning (e.g. contrast sensitivity, luminance) affect age differences in cognitive functioning. PMID:27070044

  14. Propagation of Sound in a Bose-Einstein Condensate

    International Nuclear Information System (INIS)

    Andrews, M.R.; Kurn, D.M.; Miesner, H.; Durfee, D.S.; Townsend, C.G.; Inouye, S.; Ketterle, W.

    1997-01-01

    Sound propagation has been studied in a magnetically trapped dilute Bose-Einstein condensate. Localized excitations were induced by suddenly modifying the trapping potential using the optical dipole force of a focused laser beam. The resulting propagation of sound was observed using a novel technique, rapid sequencing of nondestructive phase-contrast images. The speed of sound was determined as a function of density and found to be consistent with Bogoliubov theory. This method may generally be used to observe high-lying modes and perhaps second sound. copyright 1997 The American Physical Society

  15. Measuring the Influence of Galilean Loupe System on Near Visual Acuity of Dentists under Simulated Clinical Conditions

    Directory of Open Access Journals (Sweden)

    Iris Urlić

    2016-01-01

    Full Text Available Aim: The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC with near visual acuity of those using the Galilean telescope system (VGA2 with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. Methods: The study included 46 dentists (visual acuity 1.0 without correction. A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1 without correction at a distance of 300-400 mm (VSC; 2 with Galilean loupes with magnification of x2.5, focal length of 350mm. Results: The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001. Conclusion: If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC.

  16. The Textile Form of Sound

    DEFF Research Database (Denmark)

    Bendixen, Cecilie

    Sound is a part of architecture, and sound is complex. Upon this, sound is invisible. How is it then possible to design visual objects that interact with the sound? This paper addresses the problem of how to get access to the complexity of sound and how to make textile material revealing the form...... goemetry by analysing the sound pattern at a specific spot. This analysis is done theoretically with algorithmic systems and practical with waves in water. The paper describes the experiments and the findings, and explains how an analysis of sound can be catched in a textile form....

  17. The flex track: flexible partitioning between low- and high-acuity areas of an emergency department.

    Science.gov (United States)

    Laker, Lauren F; Froehle, Craig M; Lindsell, Christopher J; Ward, Michael J

    2014-12-01

    Emergency departments (EDs) with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated 10 beds to a fast track for low-acuity patients. We estimated the effect of a flex track policy, which involved switching up to 5 of these fast track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and Emergency Severity Index score. A flex track policy using 3 flexible beds produced the lowest mean patient waiting time of 30.9 minutes (95% confidence interval [CI] 30.6 to 31.2 minutes). The typical fast track approach of rigidly separating high- and low-acuity beds produced a mean patient wait time of 40.6 minutes (95% CI 40.2 to 50.0 minutes), 31% higher than that of the 3-bed flex track. A completely flexible ED, in which all beds can accommodate any patient, produced mean wait times of 35.1 minutes (95% CI 34.8 to 35.4 minutes). The results from the 3-bed flex track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low and high acuity can provide substantial reductions in overall patient waiting and a more efficient ED. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc

  18. Sound lateralization test in adolescent blind individuals.

    Science.gov (United States)

    Yabe, Takao; Kaga, Kimitaka

    2005-06-21

    Blind individuals require to compensate for the lack of visual information by other sensory inputs. In particular, auditory inputs are crucial to such individuals. To investigate whether blind individuals localize sound in space better than sighted individuals, we tested the auditory ability of adolescent blind individuals using a sound lateralization method. The interaural time difference discrimination thresholds of blind individuals were statistically significantly shorter than those of blind individuals with residual vision and controls. These findings suggest that blind individuals have better auditory spatial ability than individuals with visual cues; therefore, some perceptual compensation occurred in the former.

  19. Bevacizumab Injection in Patients with Age-Related Macular Degeneration Associated with Poor Initial Visual Acuity

    Directory of Open Access Journals (Sweden)

    Leila El Matri

    2012-01-01

    Full Text Available Purpose. To evaluate functional and anatomic effects of intravitreal bevacizumab in patients with neovascular AMD and initial low visual acuity. Methods. Retrospective case series of 38 eyes with neovascular AMD and initial visual acuity of 20/200 or less, treated with intravitreal bevacizumab injection. Results. Mean followup was 14.1 months ±7.1 (range: 5 to 24 months. Mean logMAR vision at baseline was 1.38 logMAR ±0.33, at 6 months was 1.14 logMAR ±0.37 (=0.001 and at 12 months was 1.22 logMar ±0.33 (=0.004. Mean baseline central retinal thickness was 431 μm ±159.7 at 6 months was 293.43 μm  ±122.79 (=10−4 and at 12 months was 293.1 μm  ±130 (=0.004. Visual acuity improved in both patients with or without prior PDT treatment. Conclusions. Intravitreal bevacizumab injection may increase the chance of visual acuity gain in neovascular AMD even in cases with initial low visual acuity.

  20. Visual Acuity is Related to Parafoveal Retinal Thickness in Patients with Retinitis Pigmentosa and Macular Cysts

    Science.gov (United States)

    Brockhurst, Robert J.; Gaudio, Alexander R.; Berson, Eliot L.

    2008-01-01

    Purpose To quantify the prevalence and effect on visual acuity of macular cysts in a large cohort of patients with retinitis pigmentosa. Methods In 316 patients with typical forms of retinitis pigmentosa, we measured visual acuities with Early Treatment Diabetic Retinopathy Study (ETDRS) charts, detected macular cysts with optical coherence tomography (OCT), and quantified retinal thicknesses by OCT. We used the FREQ, LOGISTIC, and GENMOD procedures of SAS to evaluate possible risk factors for cyst prevalence and the MIXED procedure to quantify the relationships of visual acuity to retinal thickness measured at different locations within the macula. Results We found macular cysts in 28% of the patients, 40% of whom had cysts in only one eye. Macular cysts were seen most often in patients with dominant disease and not at all in patients with X-linked disease (p = 0.006). In eyes with macular cysts, multiple regression analysis revealed that visual acuity was inversely and independently related to retinal thickness at the foveal center (p = 0.038) and within a ring spanning an eccentricity of 5° to 10° from the foveal center (p = 0.004). Conclusions Macular cysts are a common occurrence in retinitis pigmentosa, especially among patients with dominantly-inherited disease. Visual acuity is influenced by edema in the parafovea, as well as in the fovea. PMID:18552390

  1. Vernier But Not Grating Acuity Contributes to an Early Stage of Visual Word Processing.

    Science.gov (United States)

    Tan, Yufei; Tong, Xiuhong; Chen, Wei; Weng, Xuchu; He, Sheng; Zhao, Jing

    2018-03-28

    The process of reading words depends heavily on efficient visual skills, including analyzing and decomposing basic visual features. Surprisingly, previous reading-related studies have almost exclusively focused on gross aspects of visual skills, while only very few have investigated the role of finer skills. The present study filled this gap and examined the relations of two finer visual skills measured by grating acuity (the ability to resolve periodic luminance variations across space) and Vernier acuity (the ability to detect/discriminate relative locations of features) to Chinese character-processing as measured by character form-matching and lexical decision tasks in skilled adult readers. The results showed that Vernier acuity was significantly correlated with performance in character form-matching but not visual symbol form-matching, while no correlation was found between grating acuity and character processing. Interestingly, we found no correlation of the two visual skills with lexical decision performance. These findings provide for the first time empirical evidence that the finer visual skills, particularly as reflected in Vernier acuity, may directly contribute to an early stage of hierarchical word processing.

  2. Out of sight, out of mind? Relations between visual acuity and cognition.

    Science.gov (United States)

    La Fleur, Claire G; Salthouse, Timothy A

    2014-10-01

    Prior research has established significant relations between measures of sensory ability and cognitive function in adults of different ages, and several explanations for this relation have been proposed. One explanation is that sensory abilities restrict cognitive processing, a second is that cognitive abilities influence assessments of sensory ability, and a third is that both sensory function and cognition are affected by a common, potentially age-based, third factor. These explanations were investigated using mediation and moderation analyses, with near visual acuity as the sensory measure and scores on visual speed tests and auditory memory tests as the cognitive measures. Measures of visual acuity, speed, and memory were obtained from three moderately large samples, two cross-sectional (N = 380, N = 4,779) and one longitudinal (N = 2,258), with participants ranging from 18 to 90 years of age. The visual acuity and cognitive measures had different age trajectories, and the visual acuity-cognition relations were similar in each 5-year age band. The results suggest that the age-related differences and changes in near visual acuity are unlikely to contribute to the age-related differences and changes in speed and memory measures.

  3. Impact of Target Distance, Target Size, and Visual Acuity on the Video Head Impulse Test.

    Science.gov (United States)

    Judge, Paul D; Rodriguez, Amanda I; Barin, Kamran; Janky, Kristen L

    2018-05-01

    The video head impulse test (vHIT) assesses the vestibulo-ocular reflex. Few have evaluated whether environmental factors or visual acuity influence the vHIT. The purpose of this study was to evaluate the influence of target distance, target size, and visual acuity on vHIT outcomes. Thirty-eight normal controls and 8 subjects with vestibular loss (VL) participated. vHIT was completed at 3 distances and with 3 target sizes. Normal controls were subdivided on the basis of visual acuity. Corrective saccade frequency, corrective saccade amplitude, and gain were tabulated. In the normal control group, there were no significant effects of target size or visual acuity for any vHIT outcome parameters; however, gain increased as target distance decreased. The VL group demonstrated higher corrective saccade frequency and amplitude and lower gain as compared with controls. In conclusion, decreasing target distance increases gain for normal controls but not subjects with VL. Preliminarily, visual acuity does not affect vHIT outcomes.

  4. [Congenital lens subluxation: visual acuity outcomes and intraocular lens postoperative position].

    Science.gov (United States)

    Arraes, Caroline; Endriss, Daniela; Lobato, Francisco; Arraes, João; Ventura, Marcelo

    2010-01-01

    To evaluate the visual acuity outcomes and to investigate the intraocular lens (IOL) and endocapsular ring positions with ultrasound biomicroscopy in 17 eyes of 10 patients with congenital lens subluxation who underwent the same surgical technique, by the same surgeon. The study was performed in the ''Hospital de Olhos de Pernambuco'' and ''Fundação Altino Ventura''. The surgical technique consisted of phacoaspiration with implant of endocapsular ring and intraocular lens with one loop haptic amputated. The age varied from 7 to 22 years. Data on visual acuity (VA) before and after surgery, surgery follow-up period, and complications were analyzed. All patients underwent ultrasound biomicroscopy. The mean follow-up period was 2.8 years. There was a VA improvement in 17 (100%) eyes: in 12 eyes (70.6%) the visual acuity was better than 20/40; 4 (23.5%) ranged from 20/40 to 20/100, and 1 (5.9%) had visual acuity worse than 20/100, however better than the preoperative visual acuity. The posterior capsular opacification occurred in 10 eyes (58.9%). Ultrasound biomicroscopy showed that all IOL were partially decentralized, however without surpassing the pupil border limit. Endocapsular ring position was correct and there was a good capsular support in all cases. The evaluated surgical treatment provided good intraocular lens and endocapsular ring position, with VA improvement Thus, this technique is a viable, effective and safe option for the visual rehabilitation of patients with congenital lens subluxation.

  5. Sound & The Society

    DEFF Research Database (Denmark)

    Schulze, Holger

    2014-01-01

    How are those sounds you hear right now socially constructed and evaluated, how are they architecturally conceptualized and how dependant on urban planning, industrial developments and political decisions are they really? How is your ability to hear intertwined with social interactions and their ...... and their professional design? And how is listening and sounding a deeply social activity – constructing our way of living together in cities as well as in apartment houses? A radio feature with Nina Backmann, Jochen Bonz, Stefan Krebs, Esther Schelander & Holger Schulze......How are those sounds you hear right now socially constructed and evaluated, how are they architecturally conceptualized and how dependant on urban planning, industrial developments and political decisions are they really? How is your ability to hear intertwined with social interactions...

  6. Urban Sound Interfaces

    DEFF Research Database (Denmark)

    Breinbjerg, Morten

    2012-01-01

    This paper draws on the theories of Michel de Certeau and Gaston Bachelard to discuss how media architecture, in the form of urban sound interfaces, can help us perceive the complexity of the spaces we inhabit, by exploring the history and the narratives of the places in which we live. In this pa......This paper draws on the theories of Michel de Certeau and Gaston Bachelard to discuss how media architecture, in the form of urban sound interfaces, can help us perceive the complexity of the spaces we inhabit, by exploring the history and the narratives of the places in which we live....... In this paper, three sound works are discussed in relation to the iPod, which is considered as a more private way to explore urban environments, and as a way to control the individual perception of urban spaces....

  7. Predicting outdoor sound

    CERN Document Server

    Attenborough, Keith; Horoshenkov, Kirill

    2014-01-01

    1. Introduction  2. The Propagation of Sound Near Ground Surfaces in a Homogeneous Medium  3. Predicting the Acoustical Properties of Outdoor Ground Surfaces  4. Measurements of the Acoustical Properties of Ground Surfaces and Comparisons with Models  5. Predicting Effects of Source Characteristics on Outdoor Sound  6. Predictions, Approximations and Empirical Results for Ground Effect Excluding Meteorological Effects  7. Influence of Source Motion on Ground Effect and Diffraction  8. Predicting Effects of Mixed Impedance Ground  9. Predicting the Performance of Outdoor Noise Barriers  10. Predicting Effects of Vegetation, Trees and Turbulence  11. Analytical Approximations including Ground Effect, Refraction and Turbulence  12. Prediction Schemes  13. Predicting Sound in an Urban Environment.

  8. Sensorimotor posture control in the blind: superior ankle proprioceptive acuity does not compensate for vision loss.

    Science.gov (United States)

    Ozdemir, Recep A; Pourmoghaddam, Amir; Paloski, William H

    2013-09-01

    To better understand sensorimotor posture control differences between blind and sighted individuals, we examined the role of ankle joint proprioception and ankle muscle strength on postural control in healthy blind (n=13, 25-58 years) and age- and sex-matched sighted (n=15, 20-65 years) volunteers. We measured ankle joint proprioceptive acuity and isokinetic muscle strength in plantarflexion and dorsiflexion using an isokinetic dynamometer. We also assessed postural control performance during quiet bipedal stance with and without sudden postural perturbations, and during quiet unipedal stance. We found that while our blind subjects exhibited significantly better proprioceptive acuity than our sighted subjects their postural control performance was significantly poorer than that of the sighted group with eyes open, and no different from that of the sighted group with eyes closed suggesting that their superior proprioceptive acuity does not translate to improved balance control. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. The use of acuity and frailty measures for district nursing workforce plans.

    Science.gov (United States)

    David, Ami; Saunders, Mary

    2018-02-02

    This article discusses the use of Quest acuity and frailty measures for community nursing interventions to quantify and qualify the contributions of district nursing teams. It describes the use of a suite of acuity and frailty tools tested in 8 UK community service trusts over the past 5years. In addition, a competency assessment tool was used to gauge both capacity and capability of individual nurses. The consistency of the results obtained from the Quest audits offer significant evidence and potential for realigning community nursing services to offer improvements in efficiency and cost-effectiveness. The National Quality Board (NQB) improvement resource for the district nursing services ( NQB, 2017 ) recommends a robust method for classifying patient acuity/frailty/dependency. It is contended the Quest tools and their usage articulated here offer a suitable methodology.

  10. Visual Acuity Improvement in Continuous vs Divided Occlusion in Anisometropic Amblyopia.

    Science.gov (United States)

    Irfani, Irawati; Feriyanto, Feri; Oktarima, Primawita; Kartasasmita, Arief

    2018-01-01

    To compare visual acuity improvement between continuous and split part-time occlusion for the treatment of moderate and severe anisometropic amblyopia. Randomised clinical trials in 6 - 13 y.o children with moderate and severe anisometropic amblyopia. Each patient was consecutively selected with continuous or split part-time occlusion. Best corrected visual acuity's improvement was followed up to six weeks and statistical data were analyzed using chi square and unpaired t-test. Best corrected visual acuity's improvement was comparable between continuous and split part-time occlusion (0.20±0.27 vs 0.21±0.25; p = 0.79). Split part-time occlusion may be considered as an alternative treatment for moderate and severe anisometropic amblyopia treatment.

  11. Sound & The Senses

    DEFF Research Database (Denmark)

    Schulze, Holger

    2012-01-01

    How are those sounds you hear right now technically generated and post-produced, how are they aesthetically conceptualized and how culturally dependant are they really? How is your ability to hear intertwined with all the other senses and their cultural, biographical and technological constructio...... over time? And how is listening and sounding a deeply social activity – constructing our way of living together in cities as well as in apartment houses? A radio feature with Jonathan Sterne, AGF a.k.a Antye Greie, Jens Gerrit Papenburg & Holger Schulze....

  12. Handbook for sound engineers

    CERN Document Server

    Ballou, Glen

    2013-01-01

    Handbook for Sound Engineers is the most comprehensive reference available for audio engineers. All audio topics are explored: if you work on anything related to audio you should not be without this book! The 4th edition of this trusted reference has been updated to reflect changes in the industry since the publication of the 3rd edition in 2002 -- including new technologies like software-based recording systems such as Pro Tools and Sound Forge; digital recording using MP3, wave files and others; mobile audio devices such as iPods and MP3 players. Over 40 topic

  13. Sound for digital video

    CERN Document Server

    Holman, Tomlinson

    2013-01-01

    Achieve professional quality sound on a limited budget! Harness all new, Hollywood style audio techniques to bring your independent film and video productions to the next level.In Sound for Digital Video, Second Edition industry experts Tomlinson Holman and Arthur Baum give you the tools and knowledge to apply recent advances in audio capture, video recording, editing workflow, and mixing to your own film or video with stunning results. This fresh edition is chockfull of techniques, tricks, and workflow secrets that you can apply to your own projects from preproduction

  14. Beacons of Sound

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    2018-01-01

    The chapter discusses expectations and imaginations vis-à-vis the concert hall of the twenty-first century. It outlines some of the central historical implications of western culture’s haven for sounding music. Based on the author’s study of the Icelandic concert-house Harpa, the chapter considers...... how these implications, together with the prime mover’s visions, have been transformed as private investors and politicians took over. The chapter furthermore investigates the objectives regarding musical sound and the far-reaching demands concerning acoustics that modern concert halls are required...

  15. Neuroplasticity beyond sounds

    DEFF Research Database (Denmark)

    Reybrouck, Mark; Brattico, Elvira

    2015-01-01

    Capitalizing from neuroscience knowledge on how individuals are affected by the sound environment, we propose to adopt a cybernetic and ecological point of view on the musical aesthetic experience, which includes subprocesses, such as feature extraction and integration, early affective reactions...... and motor actions, style mastering and conceptualization, emotion and proprioception, evaluation and preference. In this perspective, the role of the listener/composer/performer is seen as that of an active "agent" coping in highly individual ways with the sounds. The findings concerning the neural...

  16. Eliciting Sound Memories.

    Science.gov (United States)

    Harris, Anna

    2015-11-01

    Sensory experiences are often considered triggers of memory, most famously a little French cake dipped in lime blossom tea. Sense memory can also be evoked in public history research through techniques of elicitation. In this article I reflect on different social science methods for eliciting sound memories such as the use of sonic prompts, emplaced interviewing, and sound walks. I include examples from my research on medical listening. The article considers the relevance of this work for the conduct of oral histories, arguing that such methods "break the frame," allowing room for collaborative research connections and insights into the otherwise unarticulatable.

  17. SoleSound

    DEFF Research Database (Denmark)

    Zanotto, Damiano; Turchet, Luca; Boggs, Emily Marie

    2014-01-01

    This paper introduces the design of SoleSound, a wearable system designed to deliver ecological, audio-tactile, underfoot feedback. The device, which primarily targets clinical applications, uses an audio-tactile footstep synthesis engine informed by the readings of pressure and inertial sensors...... embedded in the footwear to integrate enhanced feedback modalities into the authors' previously developed instrumented footwear. The synthesis models currently implemented in the SoleSound simulate different ground surface interactions. Unlike similar devices, the system presented here is fully portable...

  18. VISUAL ACUITY AND CLINICAL REFRACTION FOLLOWING IMPLANTATION OF VARIOUS MULTIFOCAL INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    N. N. Temirov

    2015-01-01

    Full Text Available Aim. To analyze visual acuity, clinical refraction, and defocusing tolerance after the implantation of monofocal IOL with rotational asymmetric optic (Lentis Mplus 313 MF compared with Acrysof ReSTOR SN6AD1.Materials and methods. Phacoemulsification was performed in a total of 194 patients (288 eyes, i.e., 144 patients (188 eyes with cataract and 50 patients (100 eyes with presbyopia and high ametropia. The patients were divided into two groups. Study group included 132 patients (194 eyes implanted with Lentis Mplus while control group included 62 patients (94 eyes implanted with Acrysof ReSTOR. Uncorrected distance (5 m, intermediate (50‑70 cm, and near (20‑40 cm visual acuity under photopic (85 cd/m2 and mesopic (8 cd/m2 conditions were measured, objective and subjective refractometry were performed, and defocusing tolerance was evaluated.Results. Postoperatively, uncorrected distance and near visual acuity was high while intermediate visual acuity was moderately low. Lentis Mplus patients had better near and intermediate visual acuity under mesopic conditions as compared with Acrysof ReSTOR patients. Emmetropia (target refraction was achieved in 90.2% of study group patients and in 87.2% of control group patients. In patients implanted with Lentis Mplus, refraction was measured by subjective method. Optimal A-constant for Lentis Mplus and Acrysof ReSTOR was 118.0 and 118.6, respectively. Under defocusing, Lentis Mplus patients had better visual acuity than Acrysof ReSTOR patients. This indirectly confirms better intermediate vision.Conclusions. Lentis Mplus provides better vision at various distances that does not almost depend on light levels and induces minimal dysphotopsia. 

  19. Prevalence of high astigmatism, eyeglass wear, and poor visual acuity among Native American grade school children.

    Science.gov (United States)

    Harvey, Erin M; Dobson, Velma; Miller, Joseph M

    2006-04-01

    The purpose of this study was to examine the prevalence of astigmatism and poor visual acuity and rate of eyeglass wear in grade school children who are members of a Native American tribe reported to have a high prevalence of large amounts of astigmatism. Vision screening was conducted on 1,327 first through eighth grade children attending school on the Tohono O'odham Reservation. Noncycloplegic autorefraction was conducted on the right and left eye of each child using the Nikon Retinomax K+ autorefractor, and monocular recognition acuity was tested using ETDRS logarithm of the minimum angle of resolution (logMAR) letter charts. Tohono O'odham children had a high prevalence of high astigmatism (42% had > or = 1.00 D in the right or left eye) and the axis of astigmatism was uniformly with-the-rule. However, only a small percentage of children arrived at the vision screening wearing glasses, and the prevalence of poor visual acuity (20/40 or worse in either eye) was high (35%). There was a significant relation between amount of astigmatism and uncorrected visual acuity with each additional diopter of astigmatism resulting in an additional 1 logMAR line reduction in visual acuity. Uncorrected astigmatism and poor visual acuity are prevalent among Tohono O'odham children. The results highlight the importance of improving glasses-wearing compliance, determining barriers to receiving eye care, and initiating public education programs regarding the importance of early identification and correction of astigmatism in Tohono O'odham children.

  20. Visual acuity and associated factors. The Central India Eye and Medical Study.

    Directory of Open Access Journals (Sweden)

    Vinay Nangia

    Full Text Available Visual acuity is a major parameter for quality of vision and quality of life. Information on visual acuity and its associated factors in rural societies almost untouched by any industrialization is mostly non-available. It was, therefore, the purpose of our study to determine the distribution of visual acuity and its associated factors in a rural population not marked influenced by modern lifestyle. The population-based Central India Eye and Medical Study included 4711 subjects (aged 30+ years, who underwent a detailed ophthalmologic examination including visual acuity measurement. Visual acuity measurements were available for 4706 subjects with a mean age of 49.5±13.4 years (range: 30-100 years. BCVA decreased significantly (P<0.001 from the moderately hyperopic group (0.08±0.15 logMAR to the emmetropic group (0.16±0.52 logMAR, the moderately myopic group (0.28±0.33 logMAR, the highly hyperopic group (0.66±0.62 logMAR and finally the highly myopic group (1.32±0.92 logMAR. In multivariate analysis, BCVA was significantly associated with the systemic parameters of lower age (P<0.001, higher level of education (P<0.001, higher body stature (P<0.001 and higher body mass index (P<0.001, and with the ophthalmic parameters of more hyperopic refractive error (spherical equivalent (P<0.001, shorter axial length (P<0.001, lower degree of nuclear cataract (P<0.001, and lower intraocular pressure (P = 0.006. The results suggest that in the rural population of Central India, major determinants of visual acuity were socioeconomic background, body stature and body mass index, age, refractive error, cataract and intraocular pressure.

  1. Impact of Near Work Activity on Visual Acuity among Junior High School Students

    Directory of Open Access Journals (Sweden)

    Raisha Pratiwi Indrawati

    2016-03-01

    Full Text Available Background: Uncorrected refractive error is experienced by at least 45 million productive-aged adults (aged 16–45 years old and 13 million children (aged 5–15 years old, and being the main cause of visual impairment in children worldwide and third cause of blindness in any age in Indonesia. Near work activity is estimated as one of environmental risk factor causing this refractive error, leading into decreased visual acuity. This study was conducted to analyse the impact of near work activity on visual acuity among junior high school students in Jatinangor Methods: This study was conducted in junior high school in Jatinangor, using cross sectional method. Total of 147 subjects were screened for visual impairment using Rapid Assessment of Avoidable Blindness (RAAB tumbling E chart and assesed for near work activity using questionnaire-guided interview method after informed consent had been obtained. Data were analysed using unpaired-T test and Mann-Whitney test. Results: Total diopter hours of near work activity among the group with visual acuity ≥6/18 and group with visual acuity <6/18 showed no significant difference (p=0.329, with latter group had less time-spent in near work activity. Similarly, each activity such as reading, watching TV, and using computer also showed no significant difference , except for playing games where the group with better visual acuity had shown significantly longer time spent than another group (p=0.018. Conclusions: Near work activity does not have impact on visual acuity among junior high school students, except for playing games

  2. The Auckland Optotypes: An open-access pictogram set for measuring recognition acuity.

    Science.gov (United States)

    Hamm, Lisa M; Yeoman, Janice P; Anstice, Nicola; Dakin, Steven C

    2018-03-01

    When measuring recognition acuity in a research setting, the most widely used symbols are the Early Treatment of Diabetic Retinopathy Study (ETDRS) set of 10 Sloan letters. However, the symbols are not appropriate for patients unfamiliar with letters, and acuity for individual letters is variable. Alternative pictogram sets are available, but are generally comprised of fewer items. We set out to develop an open-access set of 10 pictograms that would elicit more consistent estimates of acuity across items than the ETDRS letters from visually normal adults. We measured monocular acuity for individual uncrowded optotypes within a newly designed set (The Auckland Optotype [TAO]), the ETDRS set, and Landolt Cs. Eleven visually normal adults were assessed on regular and vanishing formats of each set. Inter-optotype reliability and ability to detect subtle differences between participants were assessed using intraclass correlations (ICC) and fractional rank precision (FRP). The TAO vanishing set showed the strongest performance (ICC = 0.97, FRP = 0.90), followed by the other vanishing sets (Sloan ICC = 0.88, FRP = 0.74; Landolt ICC = 0.86, FRP = 0.80). Within the regular format, TAO again outperformed the existing sets (TAO ICC = 0.77, FRP = 0.75; Sloan ICC = 0.65, FRP = 0.64; Landolt ICC = 0.48, FRP = 0.63). For adults with normal visual acuity, the new optotypes (in both regular and vanishing formats) are more equally legible and sensitive to subtle individual differences than their Sloan counterparts. As this set does not require observers to be able to name Roman letters, and is freely available to use and modify, it may have wide application for measurement of acuity.

  3. Posterior staphyloma in oculocutaneous albinism: another possible cause of reduced visual acuity.

    Science.gov (United States)

    Lee, Susan; Schimmenti, Lisa A; King, Richard A; Brilliant, Murray; Anderson, Jennifer L; Schoonveld, Cheri; Summers, C Gail

    2015-12-01

    Posterior staphyloma is typically associated with myopic degeneration and has not been recognized as a cause of reduced visual acuity in albinism. We report 3 cases of posterior staphyloma, each with oculocutaneous albinism (OCA) defined by phenotype and genotype. Two cases are biological sisters with OCA type 2; one was myopic and the other was hyperopic. The third case involves a man with OCA associated with Hermansky-Pudlak syndrome (HPS-5). Staphyloma may be another cause of reduced visual acuity in albinism, particularly with increasing age. It may occur in association with myopia or hyperopia. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  4. Relationship between photoreceptor outer segment length and visual acuity in diabetic macular edema.

    Science.gov (United States)

    Forooghian, Farzin; Stetson, Paul F; Meyer, Scott A; Chew, Emily Y; Wong, Wai T; Cukras, Catherine; Meyerle, Catherine B; Ferris, Frederick L

    2010-01-01

    The purpose of this study was to quantify photoreceptor outer segment (PROS) length in 27 consecutive patients (30 eyes) with diabetic macular edema using spectral domain optical coherence tomography and to describe the correlation between PROS length and visual acuity. Three spectral domain-optical coherence tomography scans were performed on all eyes during each session using Cirrus HD-OCT. A prototype algorithm was developed for quantitative assessment of PROS length. Retinal thicknesses and PROS lengths were calculated for 3 parameters: macular grid (6 x 6 mm), central subfield (1 mm), and center foveal point (0.33 mm). Intrasession repeatability was assessed using coefficient of variation and intraclass correlation coefficient. The association between retinal thickness and PROS length with visual acuity was assessed using linear regression and Pearson correlation analyses. The main outcome measures include intrasession repeatability of macular parameters and correlation of these parameters with visual acuity. Mean retinal thickness and PROS length were 298 mum to 381 microm and 30 microm to 32 mum, respectively, for macular parameters assessed in this study. Coefficient of variation values were 0.75% to 4.13% for retinal thickness and 1.97% to 14.01% for PROS length. Intraclass correlation coefficient values were 0.96 to 0.99 and 0.73 to 0.98 for retinal thickness and PROS length, respectively. Slopes from linear regression analyses assessing the association of retinal thickness and visual acuity were not significantly different from 0 (P > 0.20), whereas the slopes of PROS length and visual acuity were significantly different from 0 (P < 0.0005). Correlation coefficients for macular thickness and visual acuity ranged from 0.13 to 0.22, whereas coefficients for PROS length and visual acuity ranged from -0.61 to -0.81. Photoreceptor outer segment length can be quantitatively assessed using Cirrus HD-OCT. Although the intrasession repeatability of PROS

  5. Sound Symbolism in Basic Vocabulary

    Directory of Open Access Journals (Sweden)

    Søren Wichmann

    2010-04-01

    Full Text Available The relationship between meanings of words and their sound shapes is to a large extent arbitrary, but it is well known that languages exhibit sound symbolism effects violating arbitrariness. Evidence for sound symbolism is typically anecdotal, however. Here we present a systematic approach. Using a selection of basic vocabulary in nearly one half of the world’s languages we find commonalities among sound shapes for words referring to same concepts. These are interpreted as due to sound symbolism. Studying the effects of sound symbolism cross-linguistically is of key importance for the understanding of language evolution.

  6. ABOUT SOUNDS IN VIDEO GAMES

    Directory of Open Access Journals (Sweden)

    Denikin Anton A.

    2012-12-01

    Full Text Available The article considers the aesthetical and practical possibilities for sounds (sound design in video games and interactive applications. Outlines the key features of the game sound, such as simulation, representativeness, interactivity, immersion, randomization, and audio-visuality. The author defines the basic terminology in study of game audio, as well as identifies significant aesthetic differences between film sounds and sounds in video game projects. It is an attempt to determine the techniques of art analysis for the approaches in study of video games including aesthetics of their sounds. The article offers a range of research methods, considering the video game scoring as a contemporary creative practice.

  7. Exploring Sound with Insects

    Science.gov (United States)

    Robertson, Laura; Meyer, John R.

    2010-01-01

    Differences in insect morphology and movement during singing provide a fascinating opportunity for students to investigate insects while learning about the characteristics of sound. In the activities described here, students use a free online computer software program to explore the songs of the major singing insects and experiment with making…

  8. Second sound tracking system

    Science.gov (United States)

    Yang, Jihee; Ihas, Gary G.; Ekdahl, Dan

    2017-10-01

    It is common that a physical system resonates at a particular frequency, whose frequency depends on physical parameters which may change in time. Often, one would like to automatically track this signal as the frequency changes, measuring, for example, its amplitude. In scientific research, one would also like to utilize the standard methods, such as lock-in amplifiers, to improve the signal to noise ratio. We present a complete He ii second sound system that uses positive feedback to generate a sinusoidal signal of constant amplitude via automatic gain control. This signal is used to produce temperature/entropy waves (second sound) in superfluid helium-4 (He ii). A lock-in amplifier limits the oscillation to a desirable frequency and demodulates the received sound signal. Using this tracking system, a second sound signal probed turbulent decay in He ii. We present results showing that the tracking system is more reliable than those of a conventional fixed frequency method; there is less correlation with temperature (frequency) fluctuation when the tracking system is used.

  9. See This Sound

    DEFF Research Database (Denmark)

    Kristensen, Thomas Bjørnsten

    2009-01-01

    Anmeldelse af udstillingen See This Sound på Lentos Kunstmuseum Linz, Østrig, som markerer den foreløbige kulmination på et samarbejde mellem Lentos Kunstmuseum og Ludwig Boltzmann Institute Media.Art.Research. Udover den konkrete udstilling er samarbejdet tænkt som en ambitiøs, tværfaglig...

  10. Photoacoustic Sounds from Meteors.

    Energy Technology Data Exchange (ETDEWEB)

    Spalding, Richard E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Tencer, John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sweatt, William C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hogan, Roy E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Boslough, Mark B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Spurny, Pavel [Academy of Sciences of the Czech Republic (ASCR), Prague (Czech Republic)

    2015-03-01

    High-speed photometric observations of meteor fireballs have shown that they often produce high-amplitude light oscillations with frequency components in the kHz range, and in some cases exhibit strong millisecond flares. We built a light source with similar characteristics and illuminated various materials in the laboratory, generating audible sounds. Models suggest that light oscillations and pulses can radiatively heat dielectric materials, which in turn conductively heats the surrounding air on millisecond timescales. The sound waves can be heard if the illuminated material is sufficiently close to the observer’s ears. The mechanism described herein may explain many reports of meteors that appear to be audible while they are concurrently visible in the sky and too far away for sound to have propagated to the observer. This photoacoustic (PA) explanation provides an alternative to electrophonic (EP) sounds hypothesized to arise from electromagnetic coupling of plasma oscillation in the meteor wake to natural antennas in the vicinity of an observer.

  11. Sound of Stockholm

    DEFF Research Database (Denmark)

    Groth, Sanne Krogh

    2013-01-01

    Med sine kun 4 år bag sig er Sound of Stockholm relativt ny i det internationale festival-landskab. Festivalen er efter sigende udsprunget af en større eller mindre frustration over, at den svenske eksperimentelle musikscenes forskellige foreninger og organisationer gik hinanden bedene, og...

  12. Making Sense of Sound

    Science.gov (United States)

    Menon, Deepika; Lankford, Deanna

    2016-01-01

    From the earliest days of their lives, children are exposed to all kinds of sound, from soft, comforting voices to the frightening rumble of thunder. Consequently, children develop their own naïve explanations largely based upon their experiences with phenomena encountered every day. When new information does not support existing conceptions,…

  13. The Sounds of Metal

    DEFF Research Database (Denmark)

    Grund, Cynthia M.

    2015-01-01

    Two, I propose that this framework allows for at least a theoretical distinction between the way in which extreme metal – e.g. black metal, doom metal, funeral doom metal, death metal – relates to its sound as music and the way in which much other music may be conceived of as being constituted...

  14. The Universe of Sound

    CERN Multimedia

    CERN. Geneva

    2013-01-01

    Sound Scultor, Bill Fontana, the second winner of the Prix Ars Electronica Collide@CERN residency award, and his science inspiration partner, CERN cosmologist Subodh Patil, present their work in art and science at the CERN Globe of Science and Innovation on 4 July 2013 at 19:00.

  15. Urban Sound Ecologies

    DEFF Research Database (Denmark)

    Groth, Sanne Krogh; Samson, Kristine

    2013-01-01

    . The article concludes that the ways in which recent sound installations work with urban ecologies vary. While two of the examples blend into the urban environment, the other transfers the concert format and its mode of listening to urban space. Last, and in accordance with recent soundscape research, we point...

  16. Parameterizing Sound: Design Considerations for an Environmental Sound Database

    Science.gov (United States)

    2015-04-01

    associated with, or produced by, a physical event or human activity and 2) sound sources that are common in the environment. Reproductions or sound...Rogers S. Confrontation naming of environmental sounds. Journal of Clinical and Experimental Neuropsychology . 2000;22(6):830–864. 14 VanDerveer NJ

  17. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  18. Using patient acuity data to manage patient care outcomes and patient care costs.

    Science.gov (United States)

    Van Slyck, A; Johnson, K R

    2001-01-01

    This article describes actual reported uses for patient acuity data that go beyond historical uses in determining staffing allocations. These expanded uses include managing patient care outcomes and health care costs. The article offers the patient care executive examples of how objective, valid, and reliable data are used to drive approaches to effectively influence decision making in an increasingly competitive health care environment.

  19. Lawn mower injuries as a cause of serious visual acuity impairment – Case reports

    Directory of Open Access Journals (Sweden)

    Monika Jasielska

    2017-05-01

    Lawn mower induced eye injuries are a significant cause of serious visual acuity impairment or blindness. The presented study shows that lawn mower eye injuries are still a therapeutic, social and economic problem, yet are very preventable with proper eye protection and patients’ education. Current prevention strategies are inadequate, and therefore should be updated.

  20. The Microcirculation is Preserved in Emergency Department Low‐acuity Sepsis Patients Without Hypotension

    DEFF Research Database (Denmark)

    Skibsted, Simon; Filbin, Michael; Hou, Peter

    2014-01-01

    -acuity sepsis patients. The hypothesis was that patients with sepsis, but without hypotension, will demonstrate signs of flow abnormalities compared to noninfected control patients. Methods This was a prospective, observational study in a convenience sample of patients with sepsis and noninfected controls...

  1. High-Acuity Information Is Retained through the Cortical Visual Hierarchy of Primates.

    Science.gov (United States)

    Chelazzi, Leonardo; Santandrea, Elisa

    2018-04-18

    Vision requires perception of both coarse layout and fine details of objects. In this issue of Neuron, Lu et al. (2018) describe a possible basis for the latter: neuronal clusters in area V4 coding high-acuity information, despite the tendency along the visual hierarchy to generate global representations of objects. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Cultivating Perspectival Acuity: The Value and Cost of Integrating Theory, Craft, Research, and Practice

    Directory of Open Access Journals (Sweden)

    Joe Manganelli

    2016-10-01

    Full Text Available This paper presents reflections on integrating theory, craft, research, and practice to improve the accuracy and resiliency of each. The reflections build toward a set of statements about the value and the cost of integrating theory, craft, research, and practice. Specifically, the authors offer the Privileged Work / Non-Privileged Work Framework and concept of cultivating Perspectival Acuity.

  3. Is theta burst stimulation applied to visual cortex able to modulate peripheral visual acuity?

    Directory of Open Access Journals (Sweden)

    Sabrina Brückner

    Full Text Available Repetitive transcranial magnetic stimulation is usually applied to visual cortex to explore the effects on cortical excitability. Most researchers therefore concentrate on changes of phosphene threshold, rarely on consequences for visual performance. Thus, we investigated peripheral visual acuity in the four quadrants of the visual field using Landolt C optotypes before and after repetitive stimulation of the visual cortex. We applied continuous and intermittend theta burst stimulation with various stimulation intensities (60%, 80%, 100%, 120% of individual phosphene threshold as well as monophasic and biphasic 1 Hz stimulation, respectively. As an important result, no serious adverse effects were observed. In particular, no seizure was induced, even with theta burst stimulation applied with 120% of individual phosphene threshold. In only one case stimulation was ceased because the subject reported intolerable pain. Baseline visual acuity decreased over sessions, indicating a continuous training effect. Unexpectedly, none of the applied transcranial magnetic stimulation protocols had an effect on performance: no change in visual acuity was found in any of the four quadrants of the visual field. Binocular viewing as well as the use of peripheral instead of foveal presentation of the stimuli might have contributed to this result. Furthermore, intraindividual variability could have masked the TMS- induced effects on visual acuity.

  4. A comparison of behavioural (Landolt C) and anatomical estimates of visual acuity in archerfish (Toxotes chatareus).

    Science.gov (United States)

    Temple, S E; Manietta, D; Collin, S P

    2013-05-03

    Archerfish forage by shooting jets of water at insects above the water's surface. The challenge of detecting small prey items against a complex background suggests that they have good visual acuity, but to date this has never been tested, despite archerfish becoming an increasingly important model species for vertebrate vision. We used a modified Landolt C test to measure visual acuity behaviourally, and compared the results to their predicted minimum separable angle based on both photoreceptor and ganglion cell spacing in the retina. Both measures yielded similar estimates of visual acuity; between 3.23 and 3.57 cycles per degree (0.155-0.140° of visual arc). Such a close match between behavioural and anatomical estimates of visual acuity in fishes is unusual and may be due to our use of an ecologically relevant task that measured the resolving power of the part of the retina that has the highest photoreceptor density and that is used in aligning their spitting angle with potential targets. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, Bianca; Boonstra, F. Nienke; Cox, Ralf F. A.; van Rens, Ger; Cillessen, Antonius H. N.

    PURPOSE. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four-to nine-year-old children with visual impairment. METHODS. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  6. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.A.; van Rens, G.H.M.B.; Cillessen, A.H.N.

    2013-01-01

    Purpose. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. Methods. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  7. Perceptual learning in children with visual impairment improves near visual acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.; Rens, G. van; Cillessen, A.H.

    2013-01-01

    PURPOSE: This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. METHODS: Participants were 45 children with visual impairment and 29 children with normal vision. Children

  8. Perceptual Learning in Children With Visual Impairment Improves Near Visual Acuity

    NARCIS (Netherlands)

    Huurneman, B.; Boonstra, F.N.; Cox, R.F.A.; Rens, G.H.M.B. van; Cillessen, A.H.N.

    2013-01-01

    PURPOSE. This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four-to nine-year-old children with visual impairment. METHODS. Participants were 45 children with visual impairment and 29 children with normal vision. Children

  9. Relationship between Outer Retinal Layers Thickness and Visual Acuity in Diabetic Macular Edema

    Directory of Open Access Journals (Sweden)

    Raymond L. M. Wong

    2015-01-01

    Full Text Available Purpose. To investigate the correlation of outer retinal layers (ORL thickness and visual acuity (VA in patients with diabetic macular edema (DME. Methods. Consecutive DME patients seen at the Retina Clinic of The University of Hong Kong were recruited for OCT assessment. The ORL thickness was defined as the distance between external limiting membrane (ELM and retinal pigment epithelium (RPE at the foveal center. The correlation between total retinal thickness, ORL thickness, and vision was calculated. Results. 78 patients with DME were recruited. The mean age was 58.1 years (±11.5 years and their mean visual acuity measured with Snellen chart was 0.51 (±0.18. The correlation coefficient between total retinal thickness and visual acuity was 0.34 (P < 0.001 whereas the correlation coefficient was 0.65 between ORL thickness and visual acuity (P < 0.001. Conclusion. ORL thickness correlates better with vision than the total retinal thickness. It is a novel OCT parameter in the assessment of DME. Moreover, it could be a potential long term visual prognostic factor for patients with DME.

  10. PATTERN ELECTRORETINOGRAPHY IN RELATION TO KINETIC AND STATIC PERIMETRY AND VISUAL ACUITY IN RETINITIS PIGMENTOSA

    Directory of Open Access Journals (Sweden)

    Petra Popović

    2002-12-01

    Full Text Available Background. This study was conducted to assess whether pattern ERG is a sensitive test in evaluating the retinal function in patients with retinitis pigmentosa. We wanted to determine how pattern ERG, reflecting the activity of inner retinal layers, is related to other psychophysical tests such as perimetry and visual acuity.Methods. An analysis was performed on 50 eyes of 25 patients with typical rod-cone retinitis pigmentosa. The standard Snellen visual acuity was tested. Visual field sensitivity was measured with automated static perimetry (Octopus G2 program where mean defect was taken as an index of visual field loss. In kinetic perimetry (Goldmann the average radius of the visual field measured with target II/4 and V/4 was calculated. Transient pattern ERG and all five flash ERG responses were also measured according to ISCEV standards. Amplitudes of pattern ERG P50 and N95 waves were compared to results of visual acuity and visual field testing.Results. In our group of 25 RP patients with visual acuity ranging from 0.16 to 1.0, PERG responses were preserved much better than full field ERGs. 72% of them had still recordable PERG responses, while 48% had cone and only 32% maximal responses. Scotopic rod responses were extinguished in all eyes. The normalized amplitudes of the PERG responses were also much higher (43.5% than cone (22.5% or maximal responses (4.5%. A strong correlation of both P50 and N95 amplitudes with Octopus mean defect index was found. In kinetic perimetry the correlation with PERG amplitudes was also high, but it was better with II/4 than with V/4 target. Patients with high preserved ERG responses had good visual acuity. In all patients with visual acuity less than 0.4 both flash and pattern ERG responses were already absent.Conclusions. This study shows that pattern ERG is an objective and sensitive test in evaluating the functional visual loss in retinitis pigmentosa. Amplitudes of P50 and N95 responses are linearly

  11. Visual Temporal Acuity Is Related to Auditory Speech Perception Abilities in Cochlear Implant Users.

    Science.gov (United States)

    Jahn, Kelly N; Stevenson, Ryan A; Wallace, Mark T

    Despite significant improvements in speech perception abilities following cochlear implantation, many prelingually deafened cochlear implant (CI) recipients continue to rely heavily on visual information to develop speech and language. Increased reliance on visual cues for understanding spoken language could lead to the development of unique audiovisual integration and visual-only processing abilities in these individuals. Brain imaging studies have demonstrated that good CI performers, as indexed by auditory-only speech perception abilities, have different patterns of visual cortex activation in response to visual and auditory stimuli as compared with poor CI performers. However, no studies have examined whether speech perception performance is related to any type of visual processing abilities following cochlear implantation. The purpose of the present study was to provide a preliminary examination of the relationship between clinical, auditory-only speech perception tests, and visual temporal acuity in prelingually deafened adult CI users. It was hypothesized that prelingually deafened CI users, who exhibit better (i.e., more acute) visual temporal processing abilities would demonstrate better auditory-only speech perception performance than those with poorer visual temporal acuity. Ten prelingually deafened adult CI users were recruited for this study. Participants completed a visual temporal order judgment task to quantify visual temporal acuity. To assess auditory-only speech perception abilities, participants completed the consonant-nucleus-consonant word recognition test and the AzBio sentence recognition test. Results were analyzed using two-tailed partial Pearson correlations, Spearman's rho correlations, and independent samples t tests. Visual temporal acuity was significantly correlated with auditory-only word and sentence recognition abilities. In addition, proficient CI users, as assessed via auditory-only speech perception performance, demonstrated

  12. Correlation Between Near-Vision Acuity and the Incidence of Peritoneal Dialysis-Related Infections.

    Science.gov (United States)

    Kojima, Shigeki; Sakurada, Tsutomu; Koitabashi, Kenichiro; Kojima, Kaori; Watanabe, Shiika; Uchida, Daisuke; Kaneshiro, Nagayuki; Konno, Yusuke; Shibagaki, Yugo

    Peritoneal dialysis (PD)-related infections (PDIs) such as peritonitis, exit-site infection, and tunnel infection are serious complications affecting patients on PD. Because patients with diabetes (DM) and of older age have increased in number in Japan, the number of patients with visual impairment is estimated also to have increased. Near vision is necessary for performing proper PD daily care. However, no studies have reported whether visual impairment is likely to increase the risk of PDIs.Our study included 31 PD patients (16 men, 15 women; mean age: 61.5 ± 11.8 years; mean PD duration: 27.3 ± 20.3 months; 38.7% with DM; 54.8% wearing glasses) who performed their own PD care. At our facility and related facilities, we used a standard near-vision test chart, which classifies vision into 12 grades, from 0.1 (poor) to 1.5 (clear), to assess near-vision binocular visual acuity in those patients between March 2015 and September 2015. In addition, we retrospectively examined the medical records of the patients to determine their history of PDIs. We then evaluated the correlation between near-vision acuity and the incidence of PDIs.Mean measured near-vision acuity was 0.61 ± 0.29, and we observed no significant difference in the visual acuity of patients with and without DM (0.55 ± 0.31 vs. 0.63 ± 0.26 respectively, p = 0.477). In addition, we observed no significant difference in the incidence of PDIs between patients with and without DM (1.298 ± 1.609 per year vs. 1.164 ± 0.908 per year respectively, p = 0.804). We did not find a correlation between near-vision acuity and the incidence of PDIs (r = -0.071, p = 0.795).

  13. Product sounds : Fundamentals and application

    NARCIS (Netherlands)

    Ozcan-Vieira, E.

    2008-01-01

    Products are ubiquitous, so are the sounds emitted by products. Product sounds influence our reasoning, emotional state, purchase decisions, preference, and expectations regarding the product and the product's performance. Thus, auditory experience elicited by product sounds may not be just about

  14. Sonic mediations: body, sound, technology

    NARCIS (Netherlands)

    Birdsall, C.; Enns, A.

    2008-01-01

    Sonic Mediations: Body, Sound, Technology is a collection of original essays that represents an invaluable contribution to the burgeoning field of sound studies. While sound is often posited as having a bridging function, as a passive in-between, this volume invites readers to rethink the concept of

  15. System for actively reducing sound

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    2005-01-01

    A system for actively reducing sound from a primary noise source, such as traffic noise, comprising: a loudspeaker connector for connecting to at least one loudspeaker for generating anti-sound for reducing said noisy sound; a microphone connector for connecting to at least a first microphone placed

  16. Wood for sound.

    Science.gov (United States)

    Wegst, Ulrike G K

    2006-10-01

    The unique mechanical and acoustical properties of wood and its aesthetic appeal still make it the material of choice for musical instruments and the interior of concert halls. Worldwide, several hundred wood species are available for making wind, string, or percussion instruments. Over generations, first by trial and error and more recently by scientific approach, the most appropriate species were found for each instrument and application. Using material property charts on which acoustic properties such as the speed of sound, the characteristic impedance, the sound radiation coefficient, and the loss coefficient are plotted against one another for woods. We analyze and explain why spruce is the preferred choice for soundboards, why tropical species are favored for xylophone bars and woodwind instruments, why violinists still prefer pernambuco over other species as a bow material, and why hornbeam and birch are used in piano actions.

  17. Sounds in context

    DEFF Research Database (Denmark)

    Weed, Ethan

    A sound is never just a sound. It is becoming increasingly clear that auditory processing is best thought of not as a one-way afferent stream, but rather as an ongoing interaction between interior processes and the environment. Even the earliest stages of auditory processing in the nervous system...... time-course of contextual influence on auditory processing in three different paradigms: a simple mismatch negativity paradigm with tones of differing pitch, a multi-feature mismatch negativity paradigm in which tones were embedded in a complex musical context, and a cross-modal paradigm, in which...... auditory processing of emotional speech was modulated by an accompanying visual context. I then discuss these results in terms of their implication for how we conceive of the auditory processing stream....

  18. Sound for Health

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    From astronomy to biomedical sciences: music and sound as tools for scientific investigation Music and science are probably two of the most intrinsically linked disciplines in the spectrum of human knowledge. Science and technology have revolutionised the way artists work, interact, and create. The impact of innovative materials, new communication media, more powerful computers, and faster networks on the creative process is evident: we all can become artists in the digital era. What is less known, is that arts, and music in particular, are having a profound impact the way scientists operate, and think. From the early experiments by Kepler to the modern data sonification applications in medicine – sound and music are playing an increasingly crucial role in supporting science and driving innovation. In this talk. Dr. Domenico Vicinanza will be highlighting the complementarity and the natural synergy between music and science, with specific reference to biomedical sciences. Dr. Vicinanza will take t...

  19. Sound in Ergonomics

    Directory of Open Access Journals (Sweden)

    Jebreil Seraji

    1999-03-01

    Full Text Available The word of “Ergonomics “is composed of two separate parts: “Ergo” and” Nomos” and means the Human Factors Engineering. Indeed, Ergonomics (or human factors is the scientific discipline concerned with the understanding of interactions among humans and other elements of a system, and the profession that applies theory, principles, data and methods to design in order to optimize human well-being and overall system performance. It has applied different sciences such as Anatomy and physiology, anthropometry, engineering, psychology, biophysics and biochemistry from different ergonomics purposes. Sound when is referred as noise pollution can affect such balance in human life. The industrial noise caused by factories, traffic jam, media, and modern human activity can affect the health of the society.Here we are aimed at discussing sound from an ergonomic point of view.

  20. Pitch Based Sound Classification

    DEFF Research Database (Denmark)

    Nielsen, Andreas Brinch; Hansen, Lars Kai; Kjems, U

    2006-01-01

    A sound classification model is presented that can classify signals into music, noise and speech. The model extracts the pitch of the signal using the harmonic product spectrum. Based on the pitch estimate and a pitch error measure, features are created and used in a probabilistic model with soft......-max output function. Both linear and quadratic inputs are used. The model is trained on 2 hours of sound and tested on publicly available data. A test classification error below 0.05 with 1 s classification windows is achieved. Further more it is shown that linear input performs as well as a quadratic......, and that even though classification gets marginally better, not much is achieved by increasing the window size beyond 1 s....

  1. Progressive improvement of impaired visual acuity during the first year after transsphenoidal surgery for non-functioning pituitary macroadenoma

    NARCIS (Netherlands)

    Dekkers, O. M.; de Keizer, R. J. W.; Roelfsema, F.; Vd Klaauw, A. A.; Honkoop, P. J.; van Dulken, H.; Smit, J. W. A.; Romijn, J. A.; Pereira, A. M.

    2007-01-01

    Improvement of visual field defects continues even years after the initial surgical treatment. Because this process of continuing improvement has not been documented for visual acuity, we audited our data to explore the pattern of recovery of visual acuity until 1 year after transsphenoidal surgery

  2. Relationship between socioeconomic deprivation 
or urban/rural residence and visual acuity before cataract surgery in Northern Scotland.

    Science.gov (United States)

    Chua, Paul Y; Mustafa, Mohammed S; Scott, Neil W; Kumarasamy, Manjula; Azuara-Blanco, Augusto

    2013-01-01

    To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. 
 The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. 
 A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (χ2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). 
 Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.

  3. A Demonstration Project on Driving with Reduced Visual Acuity and a Bioptic Telescope System in the Netherlands

    NARCIS (Netherlands)

    Melis-Dankers, Bart J.M.; Kooijman, Aart C.; Brouwer, Wiebo H.; Busscher, Rens B.; Bredewoud, Ruud A.; Derksen, Peter H.; Amersfoort, Anoeska; IJsseldijk, Martin A.M.; Delden, Geert W. van; Grotenhuis, Thea H.P.A.; Witvliet, M.D.

    2008-01-01

    Background: In Europe, driving a passenger car is prohibited if binocular best corrected visual acuity (BCVA) is below 0.5 (20/40). Some US states allow people with reduced visual acuity to use a bioptic telescope system when driving. The aim of our study is to introduce a bioptic telescope system

  4. Sound source location in cavitating tip vortices

    International Nuclear Information System (INIS)

    Higuchi, H.; Taghavi, R.; Arndt, R.E.A.

    1985-01-01

    Utilizing an array of three hydrophones, individual cavitation bursts in a tip vortex could be located. Theoretically, four hydrophones are necessary. Hence the data from three hydrophones are supplemented with photographic observation of the cavitating tip vortex. The cavitation sound sources are found to be localized to within one base chord length from the hydrofoil tip. This appears to correspond to the region of initial tip vortex roll-up. A more extensive study with a four sensor array is now in progress

  5. Airspace: Antarctic Sound Transmission

    OpenAIRE

    Polli, Andrea

    2009-01-01

    This paper investigates how sound transmission can contribute to the public understanding of climate change within the context of the Poles. How have such transmission-based projects developed specifically in the Arctic and Antarctic, and how do these works create alternative pathways in order to help audiences better understand climate change? The author has created the media project Sonic Antarctica from a personal experience of the Antarctic. The work combines soundscape recordings and son...

  6. Design and Calibration Tests of an Active Sound Intensity Probe

    Directory of Open Access Journals (Sweden)

    Thomas Kletschkowski

    2008-01-01

    Full Text Available The paper presents an active sound intensity probe that can be used for sound source localization in standing wave fields. The probe consists of a sound hard tube that is terminated by a loudspeaker and an integrated pair of microphones. The microphones are used to decompose the standing wave field inside the tube into its incident and reflected part. The latter is cancelled by an adaptive controller that calculates proper driving signals for the loudspeaker. If the open end of the actively controlled tube is placed close to a vibrating surface, the radiated sound intensity can be determined by measuring the cross spectral density between the two microphones. A one-dimensional free field can be realized effectively, as first experiments performed on a simplified test bed have shown. Further tests proved that a prototype of the novel sound intensity probe can be calibrated.

  7. Spatial aspects of sound quality - and by multichannel systems subjective assessment of sound reproduced by stereo

    DEFF Research Database (Denmark)

    Choisel, Sylvain

    the fidelity with which sound reproduction systems can re-create the desired stereo image, a laser pointing technique was developed to accurately collect subjects' responses in a localization task. This method is subsequently applied in an investigation of the effects of loudspeaker directivity...... on the perceived direction of panned sources. The second part of the thesis addresses the identification of auditory attributes which play a role in the perception of sound reproduced by multichannel systems. Short musical excerpts were presented in mono, stereo and several multichannel formats to evoke various...

  8. 46 CFR 7.20 - Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island Sound and...

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island Sound and easterly entrance to Long Island Sound, NY. 7.20 Section 7.20... Atlantic Coast § 7.20 Nantucket Sound, Vineyard Sound, Buzzards Bay, Narragansett Bay, MA, Block Island...

  9. Wavefront coherence area for predicting visual acuity of post-PRK and post-PARK refractive surgery patients

    Science.gov (United States)

    Garcia, Daniel D.; van de Pol, Corina; Barsky, Brian A.; Klein, Stanley A.

    1999-06-01

    Many current corneal topography instruments (called videokeratographs) provide an `acuity index' based on corneal smoothness to analyze expected visual acuity. However, post-refractive surgery patients often exhibit better acuity than is predicted by such indices. One reason for this is that visual acuity may not necessarily be determined by overall corneal smoothness but rather by having some part of the cornea able to focus light coherently onto the fovea. We present a new method of representing visual acuity by measuring the wavefront aberration, using principles from both ray and wave optics. For each point P on the cornea, we measure the size of the associated coherence area whose optical path length (OPL), from a reference plane to P's focus, is within a certain tolerance of the OPL for P. We measured the topographies and vision of 62 eyes of patients who had undergone the corneal refractive surgery procedures of photorefractive keratectomy (PRK) and photorefractive astigmatic keratectomy (PARK). In addition to high contrast visual acuity, our vision tests included low contrast and low luminance to test the contribution of the PRK transition zone. We found our metric for visual acuity to be better than all other metrics at predicting the acuity of low contrast and low luminance. However, high contrast visual acuity was poorly predicted by all of the indices we studied, including our own. The indices provided by current videokeratographs sometimes fail for corneas whose shape differs from simple ellipsoidal models. This is the case with post-PRK and post-PARK refractive surgery patients. Our alternative representation that displays the coherence area of the wavefront has considerable advantages, and promises to be a better predictor of low contrast and low luminance visual acuity than current shape measures.

  10. Comparison on testability of visual acuity, stereo acuity and colour vision tests between children with learning disabilities and children without learning disabilities in government primary schools.

    Science.gov (United States)

    Abu Bakar, Nurul Farhana; Chen, Ai-Hong

    2014-02-01

    Children with learning disabilities might have difficulties to communicate effectively and give reliable responses as required in various visual function testing procedures. The purpose of this study was to compare the testability of visual acuity using the modified Early Treatment Diabetic Retinopathy Study (ETDRS) and Cambridge Crowding Cards, stereo acuity using Lang Stereo test II and Butterfly stereo tests and colour perception using Colour Vision Test Made Easy (CVTME) and Ishihara's Test for Colour Deficiency (Ishihara Test) between children in mainstream classes and children with learning disabilities in special education classes in government primary schools. A total of 100 primary school children (50 children from mainstream classes and 50 children from special education classes) matched in age were recruited in this cross-sectional comparative study. The testability was determined by the percentage of children who were able to give reliable respond as required by the respective tests. 'Unable to test' was defined as inappropriate response or uncooperative despite best efforts of the screener. The testability of the modified ETDRS, Butterfly stereo test and Ishihara test for respective visual function tests were found lower among children in special education classes ( P learning disabilities. Modifications of vision testing procedures are essential for children with learning disabilities.

  11. Dynamic Visual Acuity and Landing Sickness in Crewmembers Returning from Long-Duration Spaceflight

    Science.gov (United States)

    Rosenberg, M.J.F; Peters, B.T.; Reschke, M. F.

    2016-01-01

    Long-term exposure to microgravity causes sensorimotor adaptations that result in functional deficits upon returning to a gravitational environment. At landing the vestibular system and the central nervous system, responsible for coordinating head and eye movements, are adapted to microgravity and must re-adapt to the gravitational environment. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with astronauts reporting oscillopsia and blurred vision. Dynamic visual acuity (DVA) is assessed using an oscillating chair developed in the Neuroscience Laboratory at JSC. This chair is lightweight and easily portable for quick deployment in the field. The base of the chair is spring-loaded and allows for manual oscillation of the subject. Using a metronome, the chair is vertically oscillated plus or minus 2 cm at 2 Hz by an operator, to simulate walking. While the subject is being oscillated, they are asked to discern the direction of Landolt-C optotypes of varying sizes and record their direction using a gamepad. The visual acuity thresholds are determined using an algorithm that alters the size of the optotype based on the previous response of the subject using a forced-choice best parameter estimation that is able to rapidly converge on the threshold value. Visual acuity thresholds were determined both for static (seated) and dynamic (oscillating) conditions. Dynamic visual acuity is defined as the difference between the dynamic and static conditions. Dynamic visual acuity measures will be taken prior to flight (typically L-180, L-90, and L-60) and up to eight times after landing, including up to 3 times on R plus 0. Follow up measurements will be taken at R plus 1 (approximately 36 hours after landing). Long-duration International Space Station crewmembers will be tested once at the refueling stop in Europe and once again upon return to Johnson Space Center. In addition to DVA, subjective ratings of motion sickness will be recorded

  12. Active sound reduction system and method

    NARCIS (Netherlands)

    2016-01-01

    The present invention refers to an active sound reduction system and method for attenuation of sound emitted by a primary sound source, especially for attenuation of snoring sounds emitted by a human being. This system comprises a primary sound source, at least one speaker as a secondary sound

  13. Sound exposure during outdoor music festivals

    Directory of Open Access Journals (Sweden)

    Tron V Tronstad

    2016-01-01

    Full Text Available Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival’s duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization’s recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization’s recommendations. The results also show that front-of-house measurements reliably predict participant exposure.

  14. Sound Exposure During Outdoor Music Festivals

    Science.gov (United States)

    Tronstad, Tron V.; Gelderblom, Femke B.

    2016-01-01

    Most countries have guidelines to regulate sound exposure at concerts and music festivals. These guidelines limit the allowed sound pressure levels and the concert/festival's duration. In Norway, where there is such a guideline, it is up to the local authorities to impose the regulations. The need to prevent hearing-loss among festival participants is self-explanatory, but knowledge of the actual dose received by visitors is extremely scarce. This study looks at two Norwegian music festivals where only one was regulated by the Norwegian guideline for concert and music festivals. At each festival the sound exposure of four participants was monitored with noise dose meters. This study compared the exposures experienced at the two festivals, and tested them against the Norwegian guideline and the World Health Organization's recommendations. Sound levels during the concerts were higher at the festival not regulated by any guideline, and levels there exceeded both the national and the Worlds Health Organization's recommendations. The results also show that front-of-house measurements reliably predict participant exposure. PMID:27569410

  15. Broadband sound blocking in phononic crystals with rotationally symmetric inclusions.

    Science.gov (United States)

    Lee, Joong Seok; Yoo, Sungmin; Ahn, Young Kwan; Kim, Yoon Young

    2015-09-01

    This paper investigates the feasibility of broadband sound blocking with rotationally symmetric extensible inclusions introduced in phononic crystals. By varying the size of four equally shaped inclusions gradually, the phononic crystal experiences remarkable changes in its band-stop properties, such as shifting/widening of multiple Bragg bandgaps and evolution to resonance gaps. Necessary extensions of the inclusions to block sound effectively can be determined for given incident frequencies by evaluating power transmission characteristics. By arraying finite dissimilar unit cells, the resulting phononic crystal exhibits broadband sound blocking from combinational effects of multiple Bragg scattering and local resonances even with small-numbered cells.

  16. Magnetospheric radio sounding

    International Nuclear Information System (INIS)

    Ondoh, Tadanori; Nakamura, Yoshikatsu; Koseki, Teruo; Watanabe, Sigeaki; Murakami, Toshimitsu

    1977-01-01

    Radio sounding of the plasmapause from a geostationary satellite has been investigated to observe time variations of the plasmapause structure and effects of the plasma convection. In the equatorial plane, the plasmapause is located, on the average, at 4 R sub(E) (R sub(E); Earth radius), and the plasma density drops outwards from 10 2 -10 3 /cm 3 to 1-10/cm 3 in the plasmapause width of about 600 km. Plasmagrams showing a relation between the virtual range and sounding frequencies are computed by ray tracing of LF-VLF waves transmitted from a geostationary satellite, using model distributions of the electron density in the vicinity of the plasmapause. The general features of the plasmagrams are similar to the topside ionograms. The plasmagram has no penetration frequency such as f 0 F 2 , but the virtual range of the plasmagram increases rapidly with frequency above 100 kHz, since the distance between a satellite and wave reflection point increases rapidly with increasing the electron density inside the plasmapause. The plasmapause sounder on a geostationary satellite has been designed by taking account of an average propagation distance of 2 x 2.6 R sub(E) between a satellite (6.6 R sub(E)) and the plasmapause (4.0 R sub(E)), background noise, range resolution, power consumption, and receiver S/N of 10 dB. The 13-bit Barker coded pulses of baud length of 0.5 msec should be transmitted in direction parallel to the orbital plane at frequencies for 10 kHz-2MHz in a pulse interval of 0.5 sec. The transmitter peak power of 70 watts and 700 watts are required respectively in geomagnetically quiet and disturbed (strong nonthermal continuum emissions) conditions for a 400 meter cylindrical dipole of 1.2 cm diameter on the geostationary satellite. This technique will open new area of radio sounding in the magnetosphere. (auth.)

  17. The Opponent Channel Population Code of Sound Location Is an Efficient Representation of Natural Binaural Sounds

    Science.gov (United States)

    Młynarski, Wiktor

    2015-01-01

    In mammalian auditory cortex, sound source position is represented by a population of broadly tuned neurons whose firing is modulated by sounds located at all positions surrounding the animal. Peaks of their tuning curves are concentrated at lateral position, while their slopes are steepest at the interaural midline, allowing for the maximum localization accuracy in that area. These experimental observations contradict initial assumptions that the auditory space is represented as a topographic cortical map. It has been suggested that a “panoramic” code has evolved to match specific demands of the sound localization task. This work provides evidence suggesting that properties of spatial auditory neurons identified experimentally follow from a general design principle- learning a sparse, efficient representation of natural stimuli. Natural binaural sounds were recorded and served as input to a hierarchical sparse-coding model. In the first layer, left and right ear sounds were separately encoded by a population of complex-valued basis functions which separated phase and amplitude. Both parameters are known to carry information relevant for spatial hearing. Monaural input converged in the second layer, which learned a joint representation of amplitude and interaural phase difference. Spatial selectivity of each second-layer unit was measured by exposing the model to natural sound sources recorded at different positions. Obtained tuning curves match well tuning characteristics of neurons in the mammalian auditory cortex. This study connects neuronal coding of the auditory space with natural stimulus statistics and generates new experimental predictions. Moreover, results presented here suggest that cortical regions with seemingly different functions may implement the same computational strategy-efficient coding. PMID:25996373

  18. Handbook for sound engineers

    CERN Document Server

    Ballou, Glen

    2015-01-01

    Handbook for Sound Engineers is the most comprehensive reference available for audio engineers, and is a must read for all who work in audio.With contributions from many of the top professionals in the field, including Glen Ballou on interpretation systems, intercoms, assistive listening, and fundamentals and units of measurement, David Miles Huber on MIDI, Bill Whitlock on audio transformers and preamplifiers, Steve Dove on consoles, DAWs, and computers, Pat Brown on fundamentals, gain structures, and test and measurement, Ray Rayburn on virtual systems, digital interfacing, and preamplifiers

  19. Facing Sound - Voicing Art

    DEFF Research Database (Denmark)

    Lønstrup, Ansa

    2013-01-01

    This article is based on examples of contemporary audiovisual art, with a special focus on the Tony Oursler exhibition Face to Face at Aarhus Art Museum ARoS in Denmark in March-July 2012. My investigation involves a combination of qualitative interviews with visitors, observations of the audience´s...... interactions with the exhibition and the artwork in the museum space and short analyses of individual works of art based on reception aesthetics and phenomenology and inspired by newer writings on sound, voice and listening....

  20. JINGLE: THE SOUNDING SYMBOL

    Directory of Open Access Journals (Sweden)

    Bysko Maxim V.

    2013-12-01

    Full Text Available The article considers the role of jingles in the industrial era, from the occurrence of the regular radio broadcasting, sound films and television up of modern video games, audio and video podcasts, online broadcasts, and mobile communications. Jingles are researched from the point of view of the theory of symbols: the forward motion is detected in the process of development of jingles from the social symbols (radio callsigns to the individual signs-images (ringtones. The role of technical progress in the formation of jingles as important cultural audio elements of modern digital civilization.

  1. Influence of head posture on the visual acuity of children with nystagmus

    Directory of Open Access Journals (Sweden)

    Ana Carla Ramos Vieira da Costa

    2014-01-01

    Full Text Available Purpose: Evaluate the relationship between the postural alignment of the head and possible interference in the view of children. Methods: We evaluated 11 children between 2 and 7 years of age of both sexes, with the visually impaired, who had nystagmus and head lock position. The test Lea Grating Acuity Test® was used to collect measurements of visual acuity. This applied on two occasions: with and without postural alignment of the head. For reliability of the postural alignment of the head, the slopes were measured by Fisiologic® software. Results: The children had a poorer performance after physiological postural alignment. This poor performance is possible due to loss of position lock nystagmus to gain postural alignment, said to be ideal. Postural compensations were observed, and sharply increased eyestrain. Conclusion: The pursuit of traditional postural alignment affect the visual response of children with visual impairments.

  2. Temporary marked impairment of visual acuity in a case of intraocular malignant lymphoma during radiation therapy

    International Nuclear Information System (INIS)

    Miyao, Yoko; Tada, Rei; Koizumi, Noriko; Yamada, Hideaki; Kinoshita, Shigeru; Ikeda, Tsunehiko

    2000-01-01

    A 56-year-old female was referred to us for blurring of both eyes since 2 years before. She had been diagnosed as chronic uveitis and responded poorly to systemic and topical corticosteroid. Her corrected visual acuity was 0.8 right and 0.5 left. Systemic studies, including magnetic resonance imaging and gadolinium scintigraphy, were negative. Vitreous biopsy led to the diagnosis of malignant lymphoma originating from the eye. Seven days after initiation of radiation at the daily doses of 2 Gy, massive subretinal infiltration developed in her right eye forming a niveau. Systemic prednisolone induced resolution of exudate with improved visual acuity to 1.0 13 days later. This cases illustrates that radiation may induce temporary aggravation of intraocular malignant lymphoma and that it may undergo resolution following systemic corticosteroid. (author)

  3. Changes in smell acuity induced by radiation exposure of the olfactory mucosa

    International Nuclear Information System (INIS)

    Ophir, D.; Guterman, A.; Gross-Isseroff, R.

    1988-01-01

    The effects of ionizing radiation on smell acuity were assessed in 12 patients in whom the olfactory mucosa was exposed to radiation in the course of treatment for nasopharyngeal carcinoma or pituitary adenoma. Olfactory detection thresholds for two odorants (amyl acetate and eugenol) were determined before the start of radiation therapy, within a week of termination of therapy, and 1, 3, and 6 months later. The results show clearly that smell acuity is profoundly affected by therapeutic irradiation. Thresholds had increased in all 12 patients by the end of treatment and were still high one month later. Varying degrees of recovery were noted in most patients three to six months after cessation of treatment. The fate of the sense of smell deserves more attention when considering the disability caused by irradiation to certain head and neck tumors

  4. Gains following perceptual learning are closely linked to the initial visual acuity.

    Science.gov (United States)

    Yehezkel, Oren; Sterkin, Anna; Lev, Maria; Levi, Dennis M; Polat, Uri

    2016-04-28

    The goal of the present study was to evaluate the dependence of perceptual learning gains on initial visual acuity (VA), in a large sample of subjects with a wide range of VAs. A large sample of normally sighted and presbyopic subjects (N = 119; aged 40 to 63) with a wide range of uncorrected near visual acuities (VA, -0.12 to 0.8 LogMAR), underwent perceptual learning. Training consisted of detecting briefly presented Gabor stimuli under spatial and temporal masking conditions. Consistent with previous findings, perceptual learning induced a significant improvement in near VA and reading speed under conditions of limited exposure duration. Our results show that the improvements in VA and reading speed observed following perceptual learning are closely linked to the initial VA, with only a minor fraction of the observed improvement that may be attributed to the additional sessions performed by those with the worse VA.

  5. Visual acuity testing of radiographic inspectors in nondestructive inspection. Final report

    International Nuclear Information System (INIS)

    Yonemura, G.T.

    1981-06-01

    Visual acuity tests for radiographic inspectors should be correlated with the type of tasks encountered in real world radiography. The testing procedures should be capable of assessing differences in day to day performance of a given inspector as well as the performance of one inspector relative to other inspectors. Single line targets with specific parametric values for contrast, width, and blur are recommended to provide a means for testing a radiographic inspector for visual acuity. These targets may be used for periodic tests by the employing organization or for more frequent self testing by the inspector. Statistics from the National Health Survey, procedures recommended by the NAS-NRC Committee on Vision and real world radiographs have been utilized in arriving at recommended test configurations

  6. Microactuator production via high aspect ratio, high edge acuity metal fabrication technology

    Science.gov (United States)

    Guckel, H.; Christenson, T. R.

    1993-01-01

    LIGA is a procession sequence which uses x-ray lithography on photoresist layers of several hundred micrometers to produce very high edge acuity photopolymer molds. These plastic molds can be converted to metal molds via electroplating of many different metals and alloys. The end results are high edge acuity metal parts with large structural heights. The LIGA process as originally described by W. Ehrfeld can be extended by adding a surface micromachining phase to produce precision metal parts which can be assembled to form three-dimensional micromechanisms. This process, SLIGA, has been used to fabricate a dynamometer on a chip. The instrument has been fully implemented and will be applied to tribology issues, speed-torque characterization of planar magnetic micromotors and a new family of sensors.

  7. Assessing physician leadership styles: application of the situational leadership model to transitions in patient acuity.

    Science.gov (United States)

    Skog, Alexander; Peyre, Sarah E; Pozner, Charles N; Thorndike, Mary; Hicks, Gloria; Dellaripa, Paul F

    2012-01-01

    The situational leadership model suggests that an effective leader adapts leadership style depending on the followers' level of competency. We assessed the applicability and reliability of the situational leadership model when observing residents in simulated hospital floor-based scenarios. Resident teams engaged in clinical simulated scenarios. Video recordings were divided into clips based on Emergency Severity Index v4 acuity scores. Situational leadership styles were identified in clips by two physicians. Interrater reliability was determined through descriptive statistical data analysis. There were 114 participants recorded in 20 sessions, and 109 clips were reviewed and scored. There was a high level of interrater reliability (weighted kappa r = .81) supporting situational leadership model's applicability to medical teams. A suggestive correlation was found between frequency of changes in leadership style and the ability to effectively lead a medical team. The situational leadership model represents a unique tool to assess medical leadership performance in the context of acuity changes.

  8. Applying cognitive acuity theory to the development and scoring of situational judgment tests.

    Science.gov (United States)

    Leeds, J Peter

    2017-11-09

    The theory of cognitive acuity (TCA) treats the response options within items as signals to be detected and uses psychophysical methods to estimate the respondents' sensitivity to these signals. Such a framework offers new methods to construct and score situational judgment tests (SJT). Leeds (2012) defined cognitive acuity as the capacity to discern correctness and distinguish between correctness differences among simultaneously presented situation-specific response options. In this study, SJT response options were paired in order to offer the respondent a two-option choice. The contrast in correctness valence between the two options determined the magnitude of signal emission, with larger signals portending a higher probability of detection. A logarithmic relation was found between correctness valence contrast (signal stimulus) and its detectability (sensation response). Respondent sensitivity to such signals was measured and found to be related to the criterion variables. The linkage between psychophysics and elemental psychometrics may offer new directions for measurement theory.

  9. Developmental Changes in Locating Voice and Sound in Space

    Science.gov (United States)

    Kezuka, Emiko; Amano, Sachiko; Reddy, Vasudevi

    2017-01-01

    We know little about how infants locate voice and sound in a complex multi-modal space. Using a naturalistic laboratory experiment the present study tested 35 infants at 3 ages: 4 months (15 infants), 5 months (12 infants), and 7 months (8 infants). While they were engaged frontally with one experimenter, infants were presented with (a) a second experimenter’s voice and (b) castanet sounds from three different locations (left, right, and behind). There were clear increases with age in the successful localization of sounds from all directions, and a decrease in the number of repetitions required for success. Nonetheless even at 4 months two-thirds of the infants attempted to search for the voice or sound. At all ages localizing sounds from behind was more difficult and was clearly present only at 7 months. Perseverative errors (looking at the last location) were present at all ages and appeared to be task specific (only present in the 7 month-olds for the behind location). Spontaneous attention shifts by the infants between the two experimenters, evident at 7 months, suggest early evidence for infant initiation of triadic attentional engagements. There was no advantage found for voice over castanet sounds in this study. Auditory localization is a complex and contextual process emerging gradually in the first half of the first year. PMID:28979220

  10. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.

    Science.gov (United States)

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.

  11. LASER PHOTOCOAGULATION IN DIABETIC MACULAR EDEMA: EFFECTS ON VISUAL ACUITY AND MACULAR EDEMA

    Directory of Open Access Journals (Sweden)

    M.H. Dehghan

    1999-06-01

    Full Text Available Due to the importance of clinically significant macular edema in diabetic patients, this study is aimed to determine if laser photocoagulation is effective in the treatment of clinically significant diabetic macular edema. In addition, the effects of risk factors arc surveyed* This is an existing data study considering patients with clinically significant diabetic macular edema, treated with argon-green laser photocoagulation in Labbafinejad hospital, department of lasertherapy, from 1995 to 1997. in 60 (42.6% eyes the treatment method was focal, in 22 (15.6% eyes grid, and in 59 (41.84 modified grid laser photocoagulation was performed. The results are based upon deterioration of visual acuity, occurance of moderate visual loss and improvement or persistence of CSME. We studied 114 eyes from 87 patients. Two years after initial treatment, visual acuity improved in 19.1% of eyes, unchanged in 9.5% and worsened in 71.4% of eyes. After this period the rate of moderate visual loss was 28.6% and CSME was improved in 23.8% of eyes. According to our study, baseline visual acuity and retinopathy severity were two important intervening factors in response to lasertherapy. Comparing our results with natural course of diabetic macular edema, indicates that in assessing visual outcome laser photocoagulation is an effective modality in treatment of CSME, but it is not effective in maintaining or improving visual acuity, which is due to patients delay in visiting ophthalmologists and paying not enough attention to follow-up visits.

  12. Vision-guided ocular growth in a mutant chicken model with diminished visual acuity.

    Science.gov (United States)

    Ritchey, Eric R; Zelinka, Christopher; Tang, Junhua; Liu, Jun; Code, Kimberly A; Petersen-Jones, Simon; Fischer, Andy J

    2012-09-01

    Visual experience is known to guide ocular growth. We tested the hypothesis that vision-guided ocular growth is disrupted in a model system with diminished visual acuity. We examine whether ocular elongation is influenced by form-deprivation (FD) and lens-imposed defocus in the Retinopathy, Globe Enlarged (RGE) chicken. Young RGE chicks have poor visual acuity, without significant retinal pathology, resulting from a mutation in guanine nucleotide-binding protein β3 (GNB3), also known as transducin β3 or Gβ3. The mutation in GNB3 destabilizes the protein and causes a loss of Gβ3 from photoreceptors and ON-bipolar cells (Ritchey et al., 2010). FD increased ocular elongation in RGE eyes in a manner similar to that seen in wild-type (WT) eyes. By comparison, the excessive ocular elongation that results from hyperopic defocus was increased, whereas myopic defocus failed to significantly decrease ocular elongation in RGE eyes. Brief daily periods of unrestricted vision interrupting FD prevented ocular elongation in RGE chicks in a manner similar to that seen in WT chicks. Glucagonergic amacrine cells differentially expressed the immediate early gene Egr1 in response to growth-guiding stimuli in RGE retinas, but the defocus-dependent up-regulation of Egr1 was lesser in RGE retinas compared to that of WT retinas. We conclude that high visual acuity, and the retinal signaling mediated by Gβ3, is not required for emmetropization and the excessive ocular elongation caused by FD and hyperopic defocus. However, the loss of acuity and Gβ3 from RGE retinas causes enhanced responses to hyperopic defocus and diminished responses to myopic defocus. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Visual acuity, self-reported vision and falls in the EPIC-Norfolk Eye study

    OpenAIRE

    Yip, Jennifer L Y; Khawaja, Anthony P; Broadway, David; Luben, Robert; Hayat, Shabina; Dalzell, Nichola; Bhaniani, Amit; Wareham, Nicholas; Khaw, Kay-Tee; Foster, Paul J

    2013-01-01

    Purpose To examine the relationship between visual acuity (VA) and self-reported vision (SRV) in relation to falls in 8317 participants of the European Prospective Investigation into Cancer-Norfolk Eye study. Methods All participants completed a health questionnaire that included a question regarding SRV and questions regarding the number of falls in the past year. Distance VA was measured using a logMAR chart for each eye. Poor SRV was defined as those reporting fair or poor distance vision....

  14. Visual acuity measures do not reliably detect childhood refractive error--an epidemiological study.

    Directory of Open Access Journals (Sweden)

    Lisa O'Donoghue

    Full Text Available PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

  15. Macular Structures, Optical Components, and Visual Acuity in Preschool Children after Intravitreal Bevacizumab or Laser Treatment.

    Science.gov (United States)

    Lee, Yung-Sung; See, Lai-Chu; Chang, Shu-Hao; Wang, Nan-Kai; Hwang, Yih-Shiou; Lai, Chi-Chun; Chen, Kuan-Jen; Wu, Wei-Chi

    2018-05-10

    To investigate the macular structures, optical components, and visual acuity in preschool-aged children with a history of type I retinopathy of prematurity who underwent either intravitreal bevacizumab (IVB), laser, or a combination of treatments. Comparative interventional case series. A referred medical center in Taiwan. 80 eyes from 42 patients (33 IVB-treated eyes from 17 children, 24 laser-treated eyes from 13 children, and 23 laser + IVB-treated eyes from 12 children). Spectral-domain optical coherence tomography. The retinal thickness in the foveal area and the associated morphologic changes in foveal depression. Compared with the laser-treated and laser + IVB-treated eyes, the IVB-treated eyes had less myopia and deeper anterior chamber depths but presented similar axial lengths and corneal curvatures (P = .001, .002, .95 and .16, respectively). The IVB-treated eyes had significantly thinner foveal, parafoveal, and perifoveal retinal thicknesses (P < .01 for all) and a higher incidence of foveal depression than the laser- or laser + IVB-treated eyes. The macular and subfoveal choroidal thicknesses did not differ among the groups (P = .21 and .63, respectively). Moreover, compared with the eyes treated with laser or laser + IVB, the IVB-treated eyes had better uncorrected visual acuity, although a significant difference was not observed in best-corrected visual acuity (P = .008 and .29, respectively). Compared with laser therapy, IVB-treated eyes were associated with deeper anterior chamber depths and thinner foveal, parafoveal and perifoveal thicknesses. Moreover, these IVB-treated eyes had less refractive errors and better uncorrected visual acuity. Copyright © 2018. Published by Elsevier Inc.

  16. Temporal acuity and speech recognition score in noise in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Mehri Maleki

    2014-04-01

    Full Text Available Background and Aim: Multiple sclerosis (MS is one of the central nervous system diseases can be associated with a variety of symptoms such as hearing disorders. The main consequence of hearing loss is poor speech perception, and temporal acuity has important role in speech perception. We evaluated the speech perception in silent and in the presence of noise and temporal acuity in patients with multiple sclerosis.Methods: Eighteen adults with multiple sclerosis with the mean age of 37.28 years and 18 age- and sex- matched controls with the mean age of 38.00 years participated in this study. Temporal acuity and speech perception were evaluated by random gap detection test (GDT and word recognition score (WRS in three different signal to noise ratios.Results: Statistical analysis of test results revealed significant differences between the two groups (p<0.05. Analysis of gap detection test (in 4 sensation levels and word recognition score in both groups showed significant differences (p<0.001.Conclusion: According to this survey, the ability of patients with multiple sclerosis to process temporal features of stimulus was impaired. It seems that, this impairment is important factor to decrease word recognition score and speech perception.

  17. Near-field visual acuity of pigeons: effects of head location and stimulus luminance.

    Science.gov (United States)

    Hodos, W; Leibowitz, R W; Bonbright, J C

    1976-03-01

    Two pigeons were trained to discriminate a grating stimulus from a blank stimulus of equivalent luminance in a three-key chamber. The stimuli and blanks were presented behind a transparent center key. The procedure was a conditional discrimination in which pecks on the left key were reinforced if the blank had been present behind the center key and pecks on the right key were reinforced if the grating had been present behind the center key. The spatial frequency of the stimuli was varied in each session from four to 29.5 lines per millimeter in accordance with a variation of the method of constant stimuli. The number of lines per millimeter that the subjects could discriminate at threshold was determined from psychometric functions. Data were collected at five values of stimulus luminance ranging from--0.07 to 3.29 log cd/m2. The distance from the stimulus to the anterior nodal point of the eye, which was determined from measurements taken from high-speed motion-picture photographs of three additional pigeons and published intraocular measurements, was 62.0 mm. This distance and the grating detection thresholds were used to calculate the visual acuity of the birds at each level of luminance. Acuity improved with increasing luminance to a peak value of 0.52, which corresponds to a visual angle of 1.92 min, at a luminance of 2.33 log cd/m2. Further increase in luminance produced a small decline in acuity.

  18. Preschool acuity of the approximate number system correlates with school math ability.

    Science.gov (United States)

    Libertus, Melissa E; Feigenson, Lisa; Halberda, Justin

    2011-11-01

    Previous research shows a correlation between individual differences in people's school math abilities and the accuracy with which they rapidly and nonverbally approximate how many items are in a scene. This finding is surprising because the Approximate Number System (ANS) underlying numerical estimation is shared with infants and with non-human animals who never acquire formal mathematics. However, it remains unclear whether the link between individual differences in math ability and the ANS depends on formal mathematics instruction. Earlier studies demonstrating this link tested participants only after they had received many years of mathematics education, or assessed participants' ANS acuity using tasks that required additional symbolic or arithmetic processing similar to that required in standardized math tests. To ask whether the ANS and math ability are linked early in life, we measured the ANS acuity of 200 3- to 5-year-old children using a task that did not also require symbol use or arithmetic calculation. We also measured children's math ability and vocabulary size prior to the onset of formal math instruction. We found that children's ANS acuity correlated with their math ability, even when age and verbal skills were controlled for. These findings provide evidence for a relationship between the primitive sense of number and math ability starting early in life. 2011 Blackwell Publishing Ltd.

  19. Infants in Drug Withdrawal: A National Description of Nurse Workload, Infant Acuity, and Parental Needs.

    Science.gov (United States)

    Smith, Jessica G; Rogowski, Jeannette A; Schoenauer, Kathryn M; Lake, Eileen T

    Infants in drug withdrawal have complex physiological and behavioral states, requiring intensive nursing care. The study objectives were to describe acuity, parental needs, and nurse workload of infants in drug withdrawal compared with other infants. The design was cross-sectional and involved secondary nurse survey data from 6045 staff nurses from a national sample of 104 neonatal intensive care units. Nurses reported the care of 15 233 infants, 361 (2.4%) of whom were in drug withdrawal. Three-fourths of hospitals had at least 1 infant in drug withdrawal. In these hospitals, the mean number of infants in drug withdrawal was 4.7. Infant acuity was significantly higher among infants in drug withdrawal. Parents of infants in drug withdrawal required significantly more care to address complex social situations (51% vs 12%). The number of infants assigned to nurses with at least 1 infant in withdrawal (mean = 2.69) was significantly higher than typical (mean = 2.51). Given infant acuity and parental needs, policies legislating patient-to-nurse ratios should permit professional discretion on the number of patients to assign nurses caring for infants in drug withdrawal. Managers and charge nurses should consider the demands of caring for infants in drug withdrawal in assignment decisions and provide support and education.

  20. Effect of pupil size on visual acuity in a laboratory model of pseudophakic monovision.

    Science.gov (United States)

    Kawamorita, Takushi; Uozato, Hiroshi; Handa, Tomoya; Ito, Misae; Shimizu, Kimiya

    2010-05-01

    To investigate the effect of pupil size on visual acuity in pseudophakic monovision. For the simulation, a modified Liou-Brennan model eye was used. The model eye was designed to include a centered optical system, corneal asphericity, an iris pupil, a Stiles-Crawford effect, an intraocular lens, and chromatic aberration. Calculation of the modulation transfer function (MTF) was performed with ZEMAX software. Visual acuity was estimated from the MTF and the retinal threshold curve. The sizes of the entrance pupil were 2.0, 2.5, 3.0, and 4.0 mm. Decreasing pupil diameter and increasing myopia progressively improved near visual acuity. For an entrance pupil size of 2.5 mm and a refractive error of -1.50 diopters, the logMAR value (Snellen; metric) in the non-dominant eye at 40 cm was 0.06 (20/23; 6/6.9). Knowledge of the patient's pupil diameter at near fixation can assist surgeons in determining the optimum degree of myopia for successful monovision.

  1. A new dynamic visual acuity test to assess peripheral vestibular function.

    Science.gov (United States)

    Vital, Domenic; Hegemann, Stefan C A; Straumann, Dominik; Bergamin, Oliver; Bockisch, Christopher J; Angehrn, Dominik; Schmitt, Kai-Uwe; Probst, Rudolf

    2010-07-01

    To evaluate a novel test for dynamic visual acuity (DVA) that uses an adaptive algorithm for changing the size of Landolt rings presented during active or passive head impulses, and to compare the results with search-coil head impulse testing. Prospective study in healthy individuals and patients with peripheral vestibular deficits. Tertiary academic center. One hundred neuro-otologically healthy individuals (age range, 19-80 years) and 15 patients with bilateral (n = 5) or unilateral (n = 10) peripheral vestibular loss (age range, 27-72 years). Testing of static visual acuity (SVA), DVA during active and passive horizontal head rotations (optotype presentation at head velocities >100 degrees/s and >150 degrees/s), and quantitative horizontal head impulse testing with scleral search coils. Difference between SVA and DVA, that is, visual acuity loss (VA loss), gain of the high-acceleration vestibulo-ocular reflex. Passive head impulses and higher velocities were more effective than active impulses and lower velocities. Using passive head impulses and velocities higher than 150 degrees/s, the DVA test discriminated significantly (P test sensitivity was 100%, specificity was 94%, and accuracy was 95%, with search-coil head impulse testing used as a reference. In healthy individuals, VA loss increased significantly with age (P testing with Landolt rings that are adaptively changed in size enables detection of peripheral vestibular dysfunction in a fast and simple way.

  2. Does Knee Osteoarthritis Differentially Modulate Proprioceptive Acuity in the Frontal and Sagittal Planes of the Knee?

    Science.gov (United States)

    Cammarata, Martha L; Schnitzer, Thomas J; Dhaher, Yasin Y

    2012-01-01

    Objective Impaired proprioception may alter joint loading and contribute to the progression of knee osteoarthritis (OA). Though frontal plane loading at the knee contributes to OA, proprioception and its modulation with OA in this direction have not been examined. The aim of this study was to assess knee proprioceptive acuity in the frontal and sagittal planes in knee OA and healthy participants. We hypothesized that proprioceptive acuity will be decreased in the OA population in both planes of movement. Methods Thirteen persons with knee OA and fourteen healthy age-matched subjects participated. Proprioceptive acuity was assessed in varus, valgus, flexion, and extension using the threshold to detection of passive movement (TDPM). Repeated measures analysis of variance was used to assess differences in TDPM between subject groups and across movement directions. Linear regression analyses were performed to assess the correlation of TDPM between and within planes of movement. Results TDPM was found to be significantly higher (Pplanes of movement were only weakly correlated, especially in the OA group. Conclusions Consistent differences in TDPM between the OA and control groups across all movement directions suggest a global, not direction-specific, reduction in sensation in knee OA patients. PMID:21547895

  3. Low-level laser therapy improves visual acuity in adolescent and adult patients with amblyopia.

    Science.gov (United States)

    Ivandic, Boris T; Ivandic, Tomislav

    2012-03-01

    The purpose of this study was to examine the effects of low-level laser therapy (LLLT) on visual acuity in adolescent and adult patients with amblyopia. Currently, amblyopia can be treated successfully only in children. In this single-blinded, placebo-controlled study, 178 patients (mean age 46.8 years) with amblyopia caused by ametropia (110 eyes) or strabismus (121 eyes) were included. For LLLT, the area of the macula was irradiated through the conjunctiva from 1 cm distance for 30 sec with laser light (780 nm, 292 Hz, 1:1 duty cycle; average power 7.5 mW; spot area 3 mm(2)). The treatment was repeated on average 3.5 times, resulting in a mean total dose of 0.77 J/cm(2). No occlusion was applied, and no additional medication was administered. Best corrected distant visual acuity was determined using Snellen projection optotypes. In 12 patients (12 eyes), the multifocal visual evoked potential (M-VEP) was recorded. A control group of 20 patients (20 eyes) received mock treatment. Visual acuity improved in ∼90% of the eyes treated with LLLT (pamblyopia caused by ametropia and strabismus, respectively. The treatment effect was maintained for at least 6 months. The mean M-VEP amplitude increased by 1207 nV (pamblyopia caused by ametropia or strabismus.

  4. Perceptual learning in children with visual impairment improves near visual acuity.

    Science.gov (United States)

    Huurneman, Bianca; Boonstra, F Nienke; Cox, Ralf F A; van Rens, Ger; Cillessen, Antonius H N

    2013-09-17

    This study investigated whether visual perceptual learning can improve near visual acuity and reduce foveal crowding effects in four- to nine-year-old children with visual impairment. Participants were 45 children with visual impairment and 29 children with normal vision. Children with visual impairment were divided into three groups: a magnifier group (n = 12), a crowded perceptual learning group (n = 18), and an uncrowded perceptual learning group (n = 15). Children with normal vision also were divided in three groups, but were measured only at baseline. Dependent variables were single near visual acuity (NVA), crowded NVA, LH line 50% crowding NVA, number of trials, accuracy, performance time, amount of small errors, and amount of large errors. Children with visual impairment trained during six weeks, two times per week, for 30 minutes (12 training sessions). After training, children showed significant improvement of NVA in addition to specific improvements on the training task. The crowded perceptual learning group showed the largest acuity improvements (1.7 logMAR lines on the crowded chart, P children in the crowded perceptual learning group showed improvements on all NVA charts. Children with visual impairment benefit from perceptual training. While task-specific improvements were observed in all training groups, transfer to crowded NVA was largest in the crowded perceptual learning group. To our knowledge, this is the first study to provide evidence for the improvement of NVA by perceptual learning in children with visual impairment. (http://www.trialregister.nl number, NTR2537.).

  5. An assessment of the iPad as a testing platform for distance visual acuity in adults

    Science.gov (United States)

    Black, J M; Jacobs, R J; Phillips, G; Chen, L; Tan, E; Tran, A; Thompson, B

    2013-01-01

    Objectives Visual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision. Design Blinded, diagnostic test study. Setting Single centre (University) in Auckland, New Zealand. Participants University staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology. Primary and secondary outcome measures Visual acuity measured under a number of conditions. Results The iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29). Conclusions Tablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated. PMID:23794568

  6. Improving Robustness against Environmental Sounds for Directing Attention of Social Robots

    DEFF Research Database (Denmark)

    Thomsen, Nicolai Bæk; Tan, Zheng-Hua; Lindberg, Børge

    2015-01-01

    This paper presents a multi-modal system for finding out where to direct the attention of a social robot in a dialog scenario, which is robust against environmental sounds (door slamming, phone ringing etc.) and short speech segments. The method is based on combining voice activity detection (VAD......) and sound source localization (SSL) and furthermore apply post-processing to SSL to filter out short sounds. The system is tested against a baseline system in four different real-world experiments, where different sounds are used as interfering sounds. The results are promising and show a clear improvement....

  7. Sound Velocity in Soap Foams

    International Nuclear Information System (INIS)

    Wu Gong-Tao; Lü Yong-Jun; Liu Peng-Fei; Li Yi-Ning; Shi Qing-Fan

    2012-01-01

    The velocity of sound in soap foams at high gas volume fractions is experimentally studied by using the time difference method. It is found that the sound velocities increase with increasing bubble diameter, and asymptotically approach to the value in air when the diameter is larger than 12.5 mm. We propose a simple theoretical model for the sound propagation in a disordered foam. In this model, the attenuation of a sound wave due to the scattering of the bubble wall is equivalently described as the effect of an additional length. This simplicity reasonably reproduces the sound velocity in foams and the predicted results are in good agreement with the experiments. Further measurements indicate that the increase of frequency markedly slows down the sound velocity, whereas the latter does not display a strong dependence on the solution concentration

  8. Sounds like Team Spirit

    Science.gov (United States)

    Hoffman, Edward

    2002-01-01

    I recently accompanied my son Dan to one of his guitar lessons. As I sat in a separate room, I focused on the music he was playing and the beautiful, robust sound that comes from a well-played guitar. Later that night, I woke up around 3 am. I tend to have my best thoughts at this hour. The trouble is I usually roll over and fall back asleep. This time I was still awake an hour later, so I got up and jotted some notes down in my study. I was thinking about the pure, honest sound of a well-played instrument. From there my mind wandered into the realm of high-performance teams and successful projects. (I know this sounds weird, but this is the sort of thing I think about at 3 am. Maybe you have your own weird thoughts around that time.) Consider a team in relation to music. It seems to me that a crack team can achieve a beautiful, perfect unity in the same way that a band of brilliant musicians can when they're in harmony with one another. With more than a little satisfaction I have to admit, I started to think about the great work performed for you by the Knowledge Sharing team, including this magazine you are reading. Over the past two years I personally have received some of my greatest pleasures as the APPL Director from the Knowledge Sharing activities - the Masters Forums, NASA Center visits, ASK Magazine. The Knowledge Sharing team expresses such passion for their work, just like great musicians convey their passion in the music they play. In the case of Knowledge Sharing, there are many factors that have made this so enjoyable (and hopefully worthwhile for NASA). Three ingredients come to mind -- ingredients that have produced a signature sound. First, through the crazy, passionate playing of Alex Laufer, Michelle Collins, Denise Lee, and Todd Post, I always know that something startling and original is going to come out of their activities. This team has consistently done things that are unique and innovative. For me, best of all is that they are always

  9. Mercury in Long Island Sound sediments

    Science.gov (United States)

    Varekamp, J.C.; Buchholtz ten Brink, Marilyn R.; Mecray, E.I.; Kreulen, B.

    2000-01-01

    Mercury (Hg) concentrations were measured in 394 surface and core samples from Long Island Sound (LIS). The surface sediment Hg concentration data show a wide spread, ranging from 600 ppb Hg in westernmost LIS. Part of the observed range is related to variations in the bottom sedimentary environments, with higher Hg concentrations in the muddy depositional areas of central and western LIS. A strong residual trend of higher Hg values to the west remains when the data are normalized to grain size. Relationships between a tracer for sewage effluents (C. perfringens) and Hg concentrations indicate that between 0-50 % of the Hg is derived from sewage sources for most samples from the western and central basins. A higher percentage of sewage-derived Hg is found in samples from the westernmost section of LIS and in some local spots near urban centers. The remainder of the Hg is carried into the Sound with contaminated sediments from the watersheds and a small fraction enters the Sound as in situ atmospheric deposition. The Hg-depth profiles of several cores have well-defined contamination profiles that extend to pre-industrial background values. These data indicate that the Hg levels in the Sound have increased by a factor of 5-6 over the last few centuries, but Hg levels in LIS sediments have declined in modern times by up to 30 %. The concentrations of C. perfringens increased exponentially in the top core sections which had declining Hg concentrations, suggesting a recent decline in Hg fluxes that are unrelated to sewage effluents. The observed spatial and historical trends show Hg fluxes to LIS from sewage effluents, contaminated sediment input from the Connecticut River, point source inputs of strongly contaminated sediment from the Housatonic River, variations in the abundance of Hg carrier phases such as TOC and Fe, and focusing of sediment-bound Hg in association with westward sediment transport within the Sound.

  10. Sound therapies for tinnitus management.

    Science.gov (United States)

    Jastreboff, Margaret M

    2007-01-01

    Many people with bothersome (suffering) tinnitus notice that their tinnitus changes in different acoustical surroundings, it is more intrusive in silence and less profound in the sound enriched environments. This observation led to the development of treatment methods for tinnitus utilizing sound. Many of these methods are still under investigation in respect to their specific protocol and effectiveness and only some have been objectively evaluated in clinical trials. This chapter will review therapies for tinnitus using sound stimulation.

  11. Contrast visual acuity after multifocal intraocular lens implantation:aspheric versus spherical design

    Directory of Open Access Journals (Sweden)

    Jun-Hua Li

    2014-02-01

    Full Text Available AIM: To evaluate contrast visual acuity (CVA after implantation of an aspheric apodized diffractive intraocular lens (IOL or a spherical apodized diffractive IOL in cataract surgery.METHOD: This prospective randomized controlled study with a 12-month follow-up compared the results of cataract surgery with implantation of an aspheric AcrySof ReSTOR SN6AD3 IOL (30 eyes and a spherical AcrySof ReSTOR SN60D3 IOL (30 eyes. CVA with best distance correction was measured at 4 contrast levels (100%, 25%, 10% and 5% under 3 levels of chart luminance [250, 85 and 25 candelas per square meter (cd/m2] using a multi-functional visual acuity tester (MFVA-100.RESULTS:At 12 months after surgery, there were no statistically significant differences in 100% CVA and 25% CVA under 250cd/m2 (P100%=0.875 and P25%=0.057 and 85cd/m2 (P100%=0.198 and P25%=0.193 between the aspheric group and the spherical group. However, the 10% CVA and 5% CVA were significant better in aspheric group than spherical group under 250cd/m2 (P10%=0.042 and P5%=0.007 and 85cd/m2 (P10%=0.002 and P5%=0.039. Under the luminance level of 25cd/m2, no significant differences was found in the 100% CVA between the 2 group (P100%=0.245, while aspheric group had better visual acuity in the remaining 3 contracts (P25%=0.023, P10%=0.026 and P5%=0.002, respectively.CONCULSION:The aspheric AcrySof ReSTOR SN6AD3 IOL provided patients with better low-contrast visual acuity than the spherical AcrySof ReSTOR SN60D3 IOL.Keyword:cataract surgery; intraocular lens; contrast sensitivity; visual acuity

  12. Do top predators cue on sound production by mesopelagic prey?

    Science.gov (United States)

    Baumann-Pickering, S.; Checkley, D. M., Jr.; Demer, D. A.

    2016-02-01

    Deep-scattering layer (DSL) organisms, comprising a variety of mesopelagic fishes, and squids, siphonophores, crustaceans, and other invertebrates, are preferred prey for numerous large marine predators, e.g. cetaceans, seabirds, and fishes. Some of the DSL species migrate from depth during daylight to feed near the surface at night, transitioning during dusk and dawn. We investigated if any DSL organisms create sound, particularly during the crepuscular periods. Over several nights in summer 2015, underwater sound was recorded in the San Diego Trough using a high-frequency acoustic recording package (HARP, 10 Hz to 100 kHz), suspended from a drifting surface float. Acoustic backscatter from the DSL was monitored nearby using a calibrated multiple-frequency (38, 70, 120, and 200 kHz) split-beam echosounder (Simrad EK60) on a small boat. DSL organisms produced sound, between 300 and 1000 Hz, and the received levels were highest when the animals migrated past the recorder during ascent and descent. The DSL are globally present, so the observed acoustic phenomenon, if also ubiquitous, has wide-reaching implications. Sound travels farther than light or chemicals and thus can be sensed at greater distances by predators, prey, and mates. If sound is a characteristic feature of pelagic ecosystems, it likely plays a role in predator-prey relationships and overall ecosystem dynamics. Our new finding inspires numerous questions such as: Which, how, and why have DSL organisms evolved to create sound, for what do they use it and under what circumstances? Is sound production by DSL organisms truly ubiquitous, or does it depend on the local environment and species composition? How may sound production and perception be adapted to a changing environment? Do predators react to changes in sound? Can sound be used to quantify the composition of mixed-species assemblages, component densities and abundances, and hence be used in stock assessment or predictive modeling?

  13. Sound [signal] noise

    DEFF Research Database (Denmark)

    Bjørnsten, Thomas

    2012-01-01

    The article discusses the intricate relationship between sound and signification through notions of noise. The emergence of new fields of sonic artistic practices has generated several questions of how to approach sound as aesthetic form and material. During the past decade an increased attention...... has been paid to, for instance, a category such as ‘sound art’ together with an equally strengthened interest in phenomena and concepts that fall outside the accepted aesthetic procedures and constructions of what we traditionally would term as musical sound – a recurring example being ‘noise’....

  14. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  15. Sounding out the logo shot

    OpenAIRE

    Nicolai Jørgensgaard Graakjær

    2013-01-01

    This article focuses on how sound in combination with visuals (i.e. ‘branding by’) may possibly affect the signifying potentials (i.e. ‘branding effect’) of products and corporate brands (i.e. ‘branding of’) during logo shots in television commercials (i.e. ‘branding through’). This particular focus adds both to the understanding of sound in television commercials and to the understanding of sound brands. The article firstly presents a typology of sounds. Secondly, this typology is applied...

  16. Sound Is Sound: Film Sound Techniques and Infrasound Data Array Processing

    Science.gov (United States)

    Perttu, A. B.; Williams, R.; Taisne, B.; Tailpied, D.

    2017-12-01

    A multidisciplinary collaboration between earth scientists and a sound designer/composer was established to explore the possibilities of audification analysis of infrasound array data. Through the process of audification of the infrasound we began to experiment with techniques and processes borrowed from cinema to manipulate the noise content of the signal. The results of this posed the question: "Would the accuracy of infrasound data array processing be enhanced by employing these techniques?". So a new area of research was born from this collaboration and highlights the value of these interactions and the unintended paths that can occur from them. Using a reference event database, infrasound data were processed using these new techniques and the results were compared with existing techniques to asses if there was any improvement to detection capability for the array. With just under one thousand volcanoes, and a high probability of eruption, Southeast Asia offers a unique opportunity to develop and test techniques for regional monitoring of volcanoes with different technologies. While these volcanoes are monitored locally (e.g. seismometer, infrasound, geodetic and geochemistry networks) and remotely (e.g. satellite and infrasound), there are challenges and limitations to the current monitoring capability. Not only is there a high fraction of cloud cover in the region, making plume observation more difficult via satellite, there have been examples of local monitoring networks and telemetry being destroyed early in the eruptive sequence. The success of local infrasound studies to identify explosions at volcanoes, and calculate plume heights from these signals, has led to an interest in retrieving source parameters for the purpose of ash modeling with a regional network independent of cloud cover.

  17. Método computadorizado para medida da acuidade visual A computerized method for visual acuity assessment

    Directory of Open Access Journals (Sweden)

    Patrícia Katayama Kjaer Arippol

    2006-12-01

    Full Text Available OBJETIVO: Elaborar e validar teste computadorizado para medida da acuidade visual de escolares. MÉTODOS: Foi elaborado teste computadorizado para determinação da acuidade visual utilizando os padrões das tabelas logarítmicas impressas adotadas na clínica oftalmológica. Foram avaliados 90 alunos da primeira série do ensino básico, oito estudantes do curso de Tecnologia Oftálmica da UNIFESP-EPM e 10 pacientes do ambulatório de Estrabismo do Departamento de Oftalmologia da UNIFESP-EPM. Todos os sujeitos foram avaliados pelo mesmo examinador e submetidos ao exame de acuidade visual monocular, pela tabela logarítmica de optotipos E impressa e do novo teste computadorizado no mesmo momento. Os participantes forneceram os seus consentimentos após esclarecimento. RESULTADOS: As análises estatísticas revelaram correlação excelente (r>0,75 entre os dois métodos, apesar da leve tendência apresentada pelo teste computadorizado em superestimar a acuidade visual quando comparado com o padrão-ouro. O teste computadorizado apresentou sensibilidade de 100% e especificidade de 94%. CONCLUSÕES: Os resultados obtidos nos permitem dizer que o teste computadorizado pode ser utilizado como novo recurso para triagem da qualidade visual dos escolares, por ser método rápido, de fácil aplicação, barato, automático e atrativo para as crianças. A automatização desvincula o aplicador da interpretação das respostas dadas pelo aluno testado, garante padronização do procedimento, que favorece as análises de acompanhamento e pode ser realizado por diferentes examinadores. Para melhor compreensão da efetividade do teste como instrumento de triagem visual, seria interessante instituí-lo nas escolas do curso básico, após treinamento dos professores para sua aplicação.PURPOSE: To elaborate and to validate a computerized test for visual acuity screening of school-age children. METHODS: We have created a computerized test for visual acuity

  18. Lrit1, a Retinal Transmembrane Protein, Regulates Selective Synapse Formation in Cone Photoreceptor Cells and Visual Acuity.

    Science.gov (United States)

    Ueno, Akiko; Omori, Yoshihiro; Sugita, Yuko; Watanabe, Satoshi; Chaya, Taro; Kozuka, Takashi; Kon, Tetsuo; Yoshida, Satoyo; Matsushita, Kenji; Kuwahara, Ryusuke; Kajimura, Naoko; Okada, Yasushi; Furukawa, Takahisa

    2018-03-27

    In the vertebrate retina, cone photoreceptors play crucial roles in photopic vision by transmitting light-evoked signals to ON- and/or OFF-bipolar cells. However, the mechanisms underlying selective synapse formation in the cone photoreceptor pathway remain poorly understood. Here, we found that Lrit1, a leucine-rich transmembrane protein, localizes to the photoreceptor synaptic terminal and regulates the synaptic connection between cone photoreceptors and cone ON-bipolar cells. Lrit1-deficient retinas exhibit an aberrant morphology of cone photoreceptor pedicles, as well as an impairment of signal transmission from cone photoreceptors to cone ON-bipolar cells. Furthermore, we demonstrated that Lrit1 interacts with Frmpd2, a photoreceptor scaffold protein, and with mGluR6, an ON-bipolar cell-specific glutamate receptor. Additionally, Lrit1-null mice showed visual acuity impairments in their optokinetic responses. These results suggest that the Frmpd2-Lrit1-mGluR6 axis regulates selective synapse formation in cone photoreceptors and is essential for normal visual function. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.

  19. Sounding the Alarm: An Introduction to Ecological Sound Art

    Directory of Open Access Journals (Sweden)

    Jonathan Gilmurray

    2016-12-01

    Full Text Available In recent years, a number of sound artists have begun engaging with ecological issues through their work, forming a growing movement of ˝ecological sound art˝. This paper traces its development, examines its influences, and provides examples of the artists whose work is currently defining this important and timely new field.

  20. Development of Prediction Tool for Sound Absorption and Sound Insulation for Sound Proof Properties

    OpenAIRE

    Yoshio Kurosawa; Takao Yamaguchi

    2015-01-01

    High frequency automotive interior noise above 500 Hz considerably affects automotive passenger comfort. To reduce this noise, sound insulation material is often laminated on body panels or interior trim panels. For a more effective noise reduction, the sound reduction properties of this laminated structure need to be estimated. We have developed a new calculate tool that can roughly calculate the sound absorption and insulation properties of laminate structure and handy ...

  1. Sound, memory and interruption

    DEFF Research Database (Denmark)

    Pinder, David

    2016-01-01

    This chapter considers how art can interrupt the times and spaces of urban development so they might be imagined, experienced and understood differently. It focuses on the construction of the M11 Link Road through north-east London during the 1990s that demolished hundreds of homes and displaced...... around a thousand people. The highway was strongly resisted and it became the site of one of the country’s longest and largest anti-road struggles. The chapter addresses specifically Graeme Miller’s sound walk LINKED (2003), which for more than a decade has been broadcasting memories and stories...... of people who were violently displaced by the road as well as those who actively sought to halt it. Attention is given to the walk’s interruption of senses of the given and inevitable in two main ways. The first is in relation to the pace of the work and its deployment of slowness and arrest in a context...

  2. Recycling Sounds in Commercials

    DEFF Research Database (Denmark)

    Larsen, Charlotte Rørdam

    2012-01-01

    Commercials offer the opportunity for intergenerational memory and impinge on cultural memory. TV commercials for foodstuffs often make reference to past times as a way of authenticating products. This is frequently achieved using visual cues, but in this paper I would like to demonstrate how...... such references to the past and ‘the good old days’ can be achieved through sounds. In particular, I will look at commercials for Danish non-dairy spreads, especially for OMA margarine. These commercials are notable in that they contain a melody and a slogan – ‘Say the name: OMA margarine’ – that have basically...... remained the same for 70 years. Together these identifiers make OMA an interesting Danish case to study. With reference to Ann Rigney’s memorial practices or mechanisms, the study aims to demonstrate how the auditory aspects of Danish margarine commercials for frying tend to be limited in variety...

  3. The sounds of science

    Science.gov (United States)

    Carlowicz, Michael

    As scientists carefully study some aspects of the ocean environment, are they unintentionally distressing others? That is a question to be answered by Robert Benson and his colleagues in the Center for Bioacoustics at Texas A&M University.With help from a 3-year, $316,000 grant from the U.S. Office of Naval Research, Benson will study how underwater noise produced by naval operations and other sources may affect marine mammals. In Benson's study, researchers will generate random sequences of low-frequency, high-intensity (180-decibel) sounds in the Gulf of Mexico, working at an approximate distance of 1 km from sperm whale herds. Using an array of hydrophones, the scientists will listen to the characteristic clicks and whistles of the sperm whales to detect changes in the animals' direction, speed, and depth, as derived from fluctuations in their calls.

  4. Sound of proteins

    DEFF Research Database (Denmark)

    2007-01-01

    In my group we work with Molecular Dynamics to model several different proteins and protein systems. We submit our modelled molecules to changes in temperature, changes in solvent composition and even external pulling forces. To analyze our simulation results we have so far used visual inspection...... and statistical analysis of the resulting molecular trajectories (as everybody else!). However, recently I started assigning a particular sound frequency to each amino acid in the protein, and by setting the amplitude of each frequency according to the movement amplitude we can "hear" whenever two aminoacids...... example of soundfile was obtained from using Steered Molecular Dynamics for stretching the neck region of the scallop myosin molecule (in rigor, PDB-id: 1SR6), in such a way as to cause a rotation of the myosin head. Myosin is the molecule responsible for producing the force during muscle contraction...

  5. Interactive Sound Propagation using Precomputation and Statistical Approximations

    Science.gov (United States)

    Antani, Lakulish

    Acoustic phenomena such as early reflections, diffraction, and reverberation have been shown to improve the user experience in interactive virtual environments and video games. These effects arise due to repeated interactions between sound waves and objects in the environment. In interactive applications, these effects must be simulated within a prescribed time budget. We present two complementary approaches for computing such acoustic effects in real time, with plausible variation in the sound field throughout the scene. The first approach, Precomputed Acoustic Radiance Transfer, precomputes a matrix that accounts for multiple acoustic interactions between all scene objects. The matrix is used at run time to provide sound propagation effects that vary smoothly as sources and listeners move. The second approach couples two techniques---Ambient Reverberance, and Aural Proxies---to provide approximate sound propagation effects in real time, based on only the portion of the environment immediately visible to the listener. These approaches lie at different ends of a space of interactive sound propagation techniques for modeling sound propagation effects in interactive applications. The first approach emphasizes accuracy by modeling acoustic interactions between all parts of the scene; the second approach emphasizes efficiency by only taking the local environment of the listener into account. These methods have been used to efficiently generate acoustic walkthroughs of architectural models. They have also been integrated into a modern game engine, and can enable realistic, interactive sound propagation on commodity desktop PCs.

  6. Measurement of sound velocity profiles in fluids for process monitoring

    International Nuclear Information System (INIS)

    Wolf, M; Kühnicke, E; Lenz, M; Bock, M

    2012-01-01

    In ultrasonic measurements, the time of flight to the object interface is often the only information that is analysed. Conventionally it is only possible to determine distances or sound velocities if the other value is known. The current paper deals with a novel method to measure the sound propagation path length and the sound velocity in media with moving scattering particles simultaneously. Since the focal position also depends on sound velocity, it can be used as a second parameter. Via calibration curves it is possible to determine the focal position and sound velocity from the measured time of flight to the focus, which is correlated to the maximum of averaged echo signal amplitude. To move focal position along the acoustic axis, an annular array is used. This allows measuring sound velocity locally resolved without any previous knowledge of the acoustic media and without a reference reflector. In previous publications the functional efficiency of this method was shown for media with constant velocities. In this work the accuracy of these measurements is improved. Furthermore first measurements and simulations are introduced for non-homogeneous media. Therefore an experimental set-up was created to generate a linear temperature gradient, which also causes a gradient of sound velocity.

  7. Evaluation of a Public Child Eye Health Tertiary Facility for Pediatric Cataract in Southern Nigeria I: Visual Acuity Outcome

    Science.gov (United States)

    Duke, Roseline E.; Adio, Adedayo; Oparah, Sidney K.; Odey, Friday; Eyo, Okon A.

    2016-01-01

    Purpose: A retrospective study of the outcome of congenital and developmental cataract surgery was conducted in a public child eye health tertiary facility in children <16 years of age in Southern Nigeria, as part of an evaluation. Materials and Method: Manual Small Incision Cataract Surgery with or without anterior vitrectomy was performed. The outcome measures were visual acuity (VA) and change (gain) in visual acuity. The age of the child at onset, duration of delay in presentation, ocular co-morbidity, non ocular co-morbidity, gender, and pre operative visual acuity were matched with postoperative visual acuity. A total of 66 children were studied for a period of six weeks following surgery. Results: Forty eight (72.7%) children had bilateral congenital cataracts and 18 (27.3%) children had bilateral developmental cataracts. There were 38(57.6%) males and 28 (42.4%) females in the study. Thirty Five (53%) children had good visual outcome (normal vision range 6/6/ -6/18) post-operatively. The number of children with blindness (vision <3/60) decreased from 61 (92.4%) pre-operatively to 4 (6.1%) post-operatively. Post operative complication occurred in 6.8% of cases six week after surgery. Delayed presentation had an inverse relationship with change (gain) in visual acuity (r = - 0.342; p-value = 0.005). Pre-operative visual acuity had a positive relationship with post operative change (gain) in visual acuity (r = 0.618; p-value = 0.000). Conclusion: Predictors of change in visual acuity in our study were; delayed presentation and pre-operative VA. Cataract surgery in children showed clinical benefit. PMID:27347247

  8. Audibility of individual reflections in a complete sound field, III

    DEFF Research Database (Denmark)

    Bech, Søren

    1996-01-01

    This paper reports on the influence of individual reflections on the auditory localization of a loudspeaker in a small room. The sound field produced by a single loudspeaker positioned in a normal listening room has been simulated using an electroacoustic setup. The setup models the direct sound......-independent absorption coefficients of the room surfaces, and (2) a loudspeaker with directivity according to a standard two-way system and absorption coefficients according to real materials. The results have shown that subjects can distinguish reliably between timbre and localization, that the spectrum level above 2 k...

  9. Designing a Sound Reducing Wall

    Science.gov (United States)

    Erk, Kendra; Lumkes, John; Shambach, Jill; Braile, Larry; Brickler, Anne; Matthys, Anna

    2015-01-01

    Acoustical engineers use their knowledge of sound to design quiet environments (e.g., classrooms and libraries) as well as to design environments that are supposed to be loud (e.g., concert halls and football stadiums). They also design sound barriers, such as the walls along busy roadways that decrease the traffic noise heard by people in…

  10. Thinking The City Through Sound

    DEFF Research Database (Denmark)

    Kreutzfeldt, Jacob

    2011-01-01

    n Acoutic Territories. Sound Culture and Everyday Life Brandon LaBelle sets out to charts an urban topology through sound. Working his way through six acoustic territories: underground, home, sidewalk, street, shopping mall and sky/radio LaBelle investigates tensions and potentials inherent in mo...

  11. The Textile Form of Sound

    DEFF Research Database (Denmark)

    Bendixen, Cecilie

    2010-01-01

    The aim of this article is to shed light on a small part of the research taking place in the textile field. The article describes an ongoing PhD research project on textiles and sound and outlines the project's two main questions: how sound can be shaped by textiles and conversely how textiles can...

  12. Basic semantics of product sounds

    NARCIS (Netherlands)

    Özcan Vieira, E.; Van Egmond, R.

    2012-01-01

    Product experience is a result of sensory and semantic experiences with product properties. In this paper, we focus on the semantic attributes of product sounds and explore the basic components for product sound related semantics using a semantic differential paradigmand factor analysis. With two

  13. Measuring the 'complexity' of sound

    Indian Academy of Sciences (India)

    cate that specialized regions of the brain analyse different types of sounds [1]. Music, ... The left panel of figure 1 shows examples of sound–pressure waveforms from the nat- ... which is shown in the right panels in the spectrographic representation using a 45 Hz .... Plot of SFM(t) vs. time for different environmental sounds.

  14. Heart sound segmentation of pediatric auscultations using wavelet analysis.

    Science.gov (United States)

    Castro, Ana; Vinhoza, Tiago T V; Mattos, Sandra S; Coimbra, Miguel T

    2013-01-01

    Auscultation is widely applied in clinical activity, nonetheless sound interpretation is dependent on clinician training and experience. Heart sound features such as spatial loudness, relative amplitude, murmurs, and localization of each component may be indicative of pathology. In this study we propose a segmentation algorithm to extract heart sound components (S1 and S2) based on it's time and frequency characteristics. This algorithm takes advantage of the knowledge of the heart cycle times (systolic and diastolic periods) and of the spectral characteristics of each component, through wavelet analysis. Data collected in a clinical environment, and annotated by a clinician was used to assess algorithm's performance. Heart sound components were correctly identified in 99.5% of the annotated events. S1 and S2 detection rates were 90.9% and 93.3% respectively. The median difference between annotated and detected events was of 33.9 ms.

  15. Effects of interaural level differences on the externalization of sound

    DEFF Research Database (Denmark)

    Catic, Jasmina; Santurette, Sébastien; Dau, Torsten

    2012-01-01

    Distant sound sources in our environment are perceived as externalized and are thus properly localized in both direction and distance. This is due to the acoustic filtering by the head, torso, and external ears, which provides frequency-dependent shaping of binaural cues such as interaural level...... differences (ILDs) and interaural time differences (ITDs). In rooms, the sound reaching the two ears is further modified by reverberant energy, which leads to increased fluctuations in short-term ILDs and ITDs. In the present study, the effect of ILD fluctuations on the externalization of sound......, for sounds that contain frequencies above about 1 kHz the ILD fluctuations were found to be an essential cue for externalization....

  16. The Aesthetic Experience of Sound

    DEFF Research Database (Denmark)

    Breinbjerg, Morten

    2005-01-01

    to react on. In an ecological understanding of hearing our detection of audible information affords us ways of responding to our environment. In my paper I will address both these ways of using sound in relation to computer games. Since a game player is responsible for the unfolding of the game, his......The use of sound in (3D) computer games basically falls in two. Sound is used as an element in the design of the set and as a narrative. As set design sound stages the nature of the environment, it brings it to life. As a narrative it brings us information that we can choose to or perhaps need...... exploration of the virtual space laid out before him is pertinent. In this mood of exploration sound is important and heavily contributing to the aesthetic of the experience....

  17. Controlling sound with acoustic metamaterials

    DEFF Research Database (Denmark)

    Cummer, Steven A. ; Christensen, Johan; Alù, Andrea

    2016-01-01

    Acoustic metamaterials can manipulate and control sound waves in ways that are not possible in conventional materials. Metamaterials with zero, or even negative, refractive index for sound offer new possibilities for acoustic imaging and for the control of sound at subwavelength scales....... The combination of transformation acoustics theory and highly anisotropic acoustic metamaterials enables precise control over the deformation of sound fields, which can be used, for example, to hide or cloak objects from incident acoustic energy. Active acoustic metamaterials use external control to create......-scale metamaterial structures and converting laboratory experiments into useful devices. In this Review, we outline the designs and properties of materials with unusual acoustic parameters (for example, negative refractive index), discuss examples of extreme manipulation of sound and, finally, provide an overview...

  18. Short-term visual deprivation does not enhance passive tactile spatial acuity.

    Directory of Open Access Journals (Sweden)

    Michael Wong

    Full Text Available An important unresolved question in sensory neuroscience is whether, and if so with what time course, tactile perception is enhanced by visual deprivation. In three experiments involving 158 normally sighted human participants, we assessed whether tactile spatial acuity improves with short-term visual deprivation over periods ranging from under 10 to over 110 minutes. We used an automated, precisely controlled two-interval forced-choice grating orientation task to assess each participant's ability to discern the orientation of square-wave gratings pressed against the stationary index finger pad of the dominant hand. A two-down one-up staircase (Experiment 1 or a Bayesian adaptive procedure (Experiments 2 and 3 was used to determine the groove width of the grating whose orientation each participant could reliably discriminate. The experiments consistently showed that tactile grating orientation discrimination does not improve with short-term visual deprivation. In fact, we found that tactile performance degraded slightly but significantly upon a brief period of visual deprivation (Experiment 1 and did not improve over periods of up to 110 minutes of deprivation (Experiments 2 and 3. The results additionally showed that grating orientation discrimination tends to improve upon repeated testing, and confirmed that women significantly outperform men on the grating orientation task. We conclude that, contrary to two recent reports but consistent with an earlier literature, passive tactile spatial acuity is not enhanced by short-term visual deprivation. Our findings have important theoretical and practical implications. On the theoretical side, the findings set limits on the time course over which neural mechanisms such as crossmodal plasticity may operate to drive sensory changes; on the practical side, the findings suggest that researchers who compare tactile acuity of blind and sighted participants should not blindfold the sighted participants.

  19. Visual acuity after trans-scleral sutured posterior chamber intraocular lens

    International Nuclear Information System (INIS)

    Mahmood, S.A.; Zafar, S.

    2014-01-01

    To determine the changes in visual acuity in patients undergoing Trans-Scleral Sutured Posterior Chamber Intra-Ocular Lens (TSSPCIOL) implantation at a tertiary care hospital in Karachi, Pakistan. Study Design: Case series. Place and Duration of Study: LRBT Tertiary Eye Hospital, Karachi, from January 2006 to December 2010. Methodology: Records of all patients undergoing implantation of TSSPCIOL were reviewed. Patients with diagnosed glaucoma, diabetic retinopathy, macular degeneration, history of recurrent uveitis, corneal haze or central corneal scars were excluded. For the final analysis, 70 eyes out of a total of 75 were selected. Main outcomes of interest were pre and postoperative visual acuities and surgical complications. SPSS 21 was used for data analysis. Results: Pre-operatively, the average Best Spectacle-Corrected Visual Acuity (BSCVA) was 6/36 on the Snellen chart. This improved to 6/12 postoperatively. The mean improvement seen was 2.4 lines on the Snellen chart (p < 0.05). Complications include transient intraocular pressure elevation in 25 eyes (36%), IOL tilt in 4 eyes (7.1%), Cystoid Macular Edema (CME) in 4 eyes (5.7%), vitreous haemorrhage in 2 eyes (2.9%), hyphema in 2 eyes (2.9%), uveitis in 1 eye (1.4%), and retinal detachment 1 eye (1.4%). No IOL subluxation, suture erosion, iris capture, choroidal effusion or endophthalmitis was encountered and no re-operations were needed. Conclusion: TSSPCIOLs are a good management option for patients with aphakia in whom PC IOLs cannot be placed. (author)

  20. VISUAL ABILITY IN AMBLYOPIC CHILDREN COMPARED TO CHILDREN WITH NORMAL VISUAL ACUITY

    Directory of Open Access Journals (Sweden)

    Zorica Tončić

    2016-03-01

    Full Text Available Vision rehabilitation in adults with low vision, even in children, is achieved with special devices, called low vision aids, LVA. The aim of the study is to determine the degree of visual function in amblyopic children and daily activities that are best related to those of normally sighted peers with normal visual acuity. The subjects were divided into two groups, matched 1:1 by age and gender: the first group consisted of 19 amblyopic children, and the second one consisted of 19 children with normal visual acuity. The questionnaire used to assess visual ability was Cardiff Visual Ability Questionnaire for Children (CVAQC, a reliable instrument for measuring visual ability in children with low vision. The study was conducted in the only rehabilitation center for amblyopic children in this region, so this is also a pioneer study. The overall result of CVAQC in amblyopic children was 1.287 log vs.-2.956, representing statistically significantly poorer visual ability in comparison to peers without vision deficit (p˂0.005. Amblyopic children function best in entertainment activities, especially in listening music (-2.31 log; as for sport, these children report swimming to be their favourite activity (-0.99 log. In the field of education they show best results in language acquisition (-0.79 log and the worst in mathematics (3.13 log. The greatest problem is reading small print texts books (2.61 log. Low vision children have poorer result of visual function in comparison to their peers with normal visual acuity. A precise deficit assessment in the most important spheres of life can be determined by using the questionnaires, so the rehabilitation can be rightly chosen.

  1. Correlation between contrast sensitivity and visual acuity in retinitis pigmentosa patients.

    Science.gov (United States)

    Akeo, Kiyoshi; Hiida, Yoshiki; Saga, Masamichi; Inoue, Rikako; Oguchi, Yoshihisa

    2002-01-01

    High-contrast figures such as Landolt rings are insufficient to evaluate the function of the foveal cones of retinitis pigmentosa (RP) patients. We investigated the correlation between visual function as determined with Landolt rings and with the Vistech Contrast Sensitivity Function Test (VCTS) at various spatial frequencies, in addition to the Cambridge Low Contrast Grating (CLCG). The study included 30 retinitis pigmentosa patients (53 eyes). All patients were assessed with Landolt rings, the Vistech method, and the CLCG. We estimated the relative contribution of contrast sensitivity to visual acuity by VCTS at each spatial frequency and by CLCG by simple linear regression analysis. The results of the regression analysis of VCTS at 1.5, 3.0, and 6.0 cycles/degree showed a significant correlation between Landolt rings and VCTS and between CLCG and VCTS that was strongest at 6.0 cycles/degree. There was no significant correlation between Landolt rings and VCTS or between CLCG and VCTS at 12.0 and 18.0 cycles/degree. Patients with a visual acuity of 20/25 and CLCG greater than 100 were divided into two groups according to their contrast sensitivity at 18.0 cycles/degree on VCTS. The VCTS at the highest frequency was useful for evaluating the foveal visual function in RP patients having good visual acuity with the Landolt rings. Thus, contrast sensitivity should be useful in detecting minute impairment or improvement of visual function in RP. Copyright 2002 S. Karger AG, Basel

  2. Evaluation of a visual acuity test using closed Landolt-Cs to determine malingering.

    Science.gov (United States)

    Kröger, Nils; Jürgens, Clemens; Kohlmann, Thomas; Tost, Frank

    2017-12-01

    To evaluate a visual acuity test (VAT) with unexpected optotypes to detect malingering. We tested two groups. Group 1 consisted of 20 individuals with normal best corrected visual acuity (BCVA). Group 2 included participants with ocular diseases and reduced BCVA. All subjects underwent a VAT proposed by Gräf and Roesen to assess suspected malingering. This test used 36 charts with one Landolt-C per page. The first 20 optotypes were Landolt-Cs, while at positions 21, 26, 30, and 34 closed rings were presented. The testing distance was adapted to 50% of the test person's visual acuity. The test person was requested to name the gap direction of the Landolt-C within 3 s. The complete testing conversation was recorded digitally to determine response latency for each optotype from the audio tracks. The average response time was 0.46 s in group 1 and 0.45 s in group 2 for the first 20 Landolt-Cs. In both groups the response time was significantly extended (p ring compared to the mean of the first 20 Landolt-Cs, (group 1: 2.9 s; group 2: 2.3 s). The following three closed rings had also longer response times. However, these differences were not significant. Our results suggest that the proposed test may be helpful to evaluate ocular malingering. The testing procedure appeared to be feasible and showed good repeatability. The fast training effect may be a limitation for malingering detection.

  3. Individual differences in non-verbal number acuity correlate with maths achievement.

    Science.gov (United States)

    Halberda, Justin; Mazzocco, Michèle M M; Feigenson, Lisa

    2008-10-02

    Human mathematical competence emerges from two representational systems. Competence in some domains of mathematics, such as calculus, relies on symbolic representations that are unique to humans who have undergone explicit teaching. More basic numerical intuitions are supported by an evolutionarily ancient approximate number system that is shared by adults, infants and non-human animals-these groups can all represent the approximate number of items in visual or auditory arrays without verbally counting, and use this capacity to guide everyday behaviour such as foraging. Despite the widespread nature of the approximate number system both across species and across development, it is not known whether some individuals have a more precise non-verbal 'number sense' than others. Furthermore, the extent to which this system interfaces with the formal, symbolic maths abilities that humans acquire by explicit instruction remains unknown. Here we show that there are large individual differences in the non-verbal approximation abilities of 14-year-old children, and that these individual differences in the present correlate with children's past scores on standardized maths achievement tests, extending all the way back to kindergarten. Moreover, this correlation remains significant when controlling for individual differences in other cognitive and performance factors. Our results show that individual differences in achievement in school mathematics are related to individual differences in the acuity of an evolutionarily ancient, unlearned approximate number sense. Further research will determine whether early differences in number sense acuity affect later maths learning, whether maths education enhances number sense acuity, and the extent to which tertiary factors can affect both.

  4. A study of static, kinetic, and dynamic visual acuity in 102 Japanese professional baseball players

    Directory of Open Access Journals (Sweden)

    Hoshina K

    2013-03-01

    Full Text Available Kohji Hoshina,1 Yuichi Tagami,2 Osamu Mimura,3 Hiroshi Edagawa,4 Masao Matsubara,5 Teiichi Nakayama6 1Hoshina Eye Clinic, Nishinomiya, Japan; 2Department of Ophthalmology, Kobe Century Memorial Hospital, Kobe, Japan; 3Department of Ophthalmology, Hyogo College of Medicine, Nishinomiya, Japan; 4Edagawa Eye Clinic, Tokyo, Japan; 5Department of Ophthalmology, Tokyo Women's Medical University Medical Center East, Tokyo, Japan; 6Ritsumeikan University, Kyoto, Japan Background: It seemed that visual functions might have some effects on the performance of baseball players. We measured static, kinetic, and dynamic visual acuity (SVA, KVA, and DVA, respectively of Japanese professional baseball players to ascertain whether there would be any difference in SVA, KVA, and DVA among player groups stratified according to their performance level. Methods: The subjects were 102 male professional baseball players with a mean age of 26 years who were members of a Japanese professional baseball club from 2000 to 2009. They were stratified into three groups according to their performance level: A (players who were on the roster of the top-level team all the time throughout the study period, B (players who were on the roster of the top-level team sometimes but not all the time, and C (players who were never on the roster of the top-level team. They were interviewed for the use of corrective visual aids, and examined for SVA, KVA, and DVA. The measurements of these parameters were compared among groups A, B, and C. We also investigated and analyzed the association of KVA or DVA with player position (pitchers or fielders and with hand dominance for batting. KVA was compared between the pitchers and the fielders because they each require different playing skills. DVA was compared between the right-handed and the left-handed batters. Results: There was no statistically significant difference among groups A, B, and C. There was a statistically significant difference in

  5. Visual acuity and visual skills in Malaysian children with learning disabilities

    Directory of Open Access Journals (Sweden)

    Muzaliha MN

    2012-09-01

    Full Text Available Mohd-Nor Muzaliha,1 Buang Nurhamiza,1 Adil Hussein,1 Abdul-Rani Norabibas,1 Jaafar Mohd-Hisham-Basrun,1 Abdullah Sarimah,2 Seo-Wei Leo,3 Ismail Shatriah11Department of Ophthalmology, 2Biostatistics and Research Methodology Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia; 3Paediatric Ophthalmology and Strabismus Unit, Department of Ophthalmology, Tan Tock Seng Hospital, SingaporeBackground: There is limited data in the literature concerning the visual status and skills in children with learning disabilities, particularly within the Asian population. This study is aimed to determine visual acuity and visual skills in children with learning disabilities in primary schools within the suburban Kota Bharu district in Malaysia.Methods: We examined 1010 children with learning disabilities aged between 8–12 years from 40 primary schools in the Kota Bharu district, Malaysia from January 2009 to March 2010. These children were identified based on their performance in a screening test known as the Early Intervention Class for Reading and Writing Screening Test conducted by the Ministry of Education, Malaysia. Complete ocular examinations and visual skills assessment included near point of convergence, amplitude of accommodation, accommodative facility, convergence break and recovery, divergence break and recovery, and developmental eye movement tests for all subjects.Results: A total of 4.8% of students had visual acuity worse than 6/12 (20/40, 14.0% had convergence insufficiency, 28.3% displayed poor accommodative amplitude, and 26.0% showed signs of accommodative infacility. A total of 12.1% of the students had poor convergence break, 45.7% displayed poor convergence recovery, 37.4% showed poor divergence break, and 66.3% were noted to have poor divergence recovery. The mean horizontal developmental eye movement was significantly prolonged.Conclusion: Although their visual acuity was satisfactory, nearly 30% of the

  6. Origins of Superior Dynamic Visual Acuity in Baseball Players: Superior Eye Movements or Superior Image Processing

    OpenAIRE

    Uchida, Yusuke; Kudoh, Daisuke; Murakami, Akira; Honda, Masaaki; Kitazawa, Shigeru

    2012-01-01

    Dynamic visual acuity (DVA) is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DV...

  7. Nonlocal nonlinear coupling of kinetic sound waves

    Directory of Open Access Journals (Sweden)

    O. Lyubchyk

    2014-11-01

    Full Text Available We study three-wave resonant interactions among kinetic-scale oblique sound waves in the low-frequency range below the ion cyclotron frequency. The nonlinear eigenmode equation is derived in the framework of a two-fluid plasma model. Because of dispersive modifications at small wavelengths perpendicular to the background magnetic field, these waves become a decay-type mode. We found two decay channels, one into co-propagating product waves (forward decay, and another into counter-propagating product waves (reverse decay. All wavenumbers in the forward decay are similar and hence this decay is local in wavenumber space. On the contrary, the reverse decay generates waves with wavenumbers that are much larger than in the original pump waves and is therefore intrinsically nonlocal. In general, the reverse decay is significantly faster than the forward one, suggesting a nonlocal spectral transport induced by oblique sound waves. Even with low-amplitude sound waves the nonlinear interaction rate is larger than the collisionless dissipation rate. Possible applications regarding acoustic waves observed in the solar corona, solar wind, and topside ionosphere are briefly discussed.

  8. Cortical processing of dynamic sound envelope transitions.

    Science.gov (United States)

    Zhou, Yi; Wang, Xiaoqin

    2010-12-08

    Slow envelope fluctuations in the range of 2-20 Hz provide important segmental cues for processing communication sounds. For a successful segmentation, a neural processor must capture envelope features associated with the rise and fall of signal energy, a process that is often challenged by the interference of background noise. This study investigated the neural representations of slowly varying envelopes in quiet and in background noise in the primary auditory cortex (A1) of awake marmoset monkeys. We characterized envelope features based on the local average and rate of change of sound level in envelope waveforms and identified envelope features to which neurons were selective by reverse correlation. Our results showed that envelope feature selectivity of A1 neurons was correlated with the degree of nonmonotonicity in their static rate-level functions. Nonmonotonic neurons exhibited greater feature selectivity than monotonic neurons in quiet and in background noise. The diverse envelope feature selectivity decreased spike-timing correlation among A1 neurons in response to the same envelope waveforms. As a result, the variability, but not the average, of the ensemble responses of A1 neurons represented more faithfully the dynamic transitions in low-frequency sound envelopes both in quiet and in background noise.

  9. Three-dimensional interpretation of TEM soundings

    Science.gov (United States)

    Barsukov, P. O.; Fainberg, E. B.

    2013-07-01

    We describe the approach to the interpretation of electromagnetic (EM) sounding data which iteratively adjusts the three-dimensional (3D) model of the environment by local one-dimensional (1D) transformations and inversions and reconstructs the geometrical skeleton of the model. The final 3D inversion is carried out with the minimal number of the sought parameters. At each step of the interpretation, the model of the medium is corrected according to the geological information. The practical examples of the suggested method are presented.

  10. Localization of a sound source in in a guided medium and reverberating field. Contribution to a study on leak localization in the internal wall of containment of a nuclear reactor in the case of a severe reactor accident; Localisation d`une source acoustique en milieu guide et champ reverberant. Contribution a l`etude sur la localisation de fuite de l`enceinte de confinement d`une centrale nucleaire en situation accidentelle grave

    Energy Technology Data Exchange (ETDEWEB)

    Thomann, F

    1996-11-28

    Basic data necessary for the localization of a leak in the internal wall of the containment are presented by studying the sound generated by gas jets coming out of (leaking fissures) as well as propagation in a guided medium. The results acquired have led us to choose the simple intercorrelation method and the matched filed processing method, both of which are likely to adequately handle our problems. Whereas the intercorrelation method appears to be limited in scope when dealing in the guided medium, the matched field processing is suited to leak localization over a surface of approximately 1000 m{sup 2} (for a total surface of 10 000 m{sup 2}). Preliminary studies on the leak signal and on replicated signals have led us to limit the frequency band to 2600 - 3000 Hz. We have succeeded in locating a leak situated in an ordinary position with a minimum amount of replicated signals and basic data. We have improved on the estimation of Bartlett and MVDE (minimum variance distortion less filter) rendering them even more effective. Afterwards, we considered the severe accident situation and showed that the system can be installed in situ. (author) 88 refs.

  11. Fourth sound in relativistic superfluidity theory

    International Nuclear Information System (INIS)

    Vil'chinskij, S.I.; Fomin, P.I.

    1995-01-01

    The Lorentz-covariant equations describing propagation of the fourth sound in the relativistic theory of superfluidity are derived. The expressions for the velocity of the fourth sound are obtained. The character of oscillation in sound is determined

  12. Normative monocular visual acuity for early treatment diabetic retinopathy study charts in emmetropic children 5 to 12 years of age.

    Science.gov (United States)

    Dobson, Velma; Clifford-Donaldson, Candice E; Green, Tina K; Miller, Joseph M; Harvey, Erin M

    2009-07-01

    To provide normative data for children tested with Early Treatment Diabetic Retinopathy Study (ETDRS) charts. Cross-sectional study. A total of 252 Native American (Tohono O'odham) children aged 5 to 12 years. On the basis of cycloplegic refraction conducted on the day of testing, all were emmetropic (myopia < or =0.25 diopter [D] spherical equivalent, hyperopia < or =1.00 D spherical equivalent, and astigmatism < or =0.50 D in both eyes). Monocular visual acuity was tested at 4 m, using 1 ETDRS chart for the right eye (RE) and another for the left eye (LE). Visual acuity was scored as the total number of letters correctly identified, by naming or matching to letters on a lap card, and as the smallest letter size for which the child identified 3 of 5 letters correctly. Visual acuity results did not differ for the RE versus the LE, so data are reported for the RE only. Mean visual acuity for 5-year-olds (0.16 logarithm of the minimum angle of resolution [logMAR] [20/29]) was significantly worse than for 8-, 9-, 10-, 11-, and 12-year-olds (0.05 logMAR [20/22] or better at each age). The lower 95% prediction limit for determining whether a child has visual acuity within the normal range was 0.38 (20/48) for 5-year-olds and 0.30 (20/40) for 6- to 12-year-olds, which was reduced to 0.32 (20/42) for 5-year-olds and 0.21 (20/32) for 6- to 12-year-olds when recalculated with outlying data points removed. Mean interocular acuity difference did not vary by age, averaging less than 1 logMAR line at each age, with a lower 95% prediction limit of 0.17 log unit (1.7 logMAR lines) across all ages. For monocular visual acuity based on ETDRS charts to be in the normal range, it must be better than 20/50 for 5-year-olds and better than 20/40 for 6- to 12-year-olds. Normal interocular acuity difference includes values of less than 2 logMAR lines. Normative ETDRS visual acuity values are not as good as norms reported for adults, suggesting that a child's visual acuity results should

  13. EUVS Sounding Rocket Payload

    Science.gov (United States)

    Stern, Alan S.

    1996-01-01

    During the first half of this year (CY 1996), the EUVS project began preparations of the EUVS payload for the upcoming NASA sounding rocket flight 36.148CL, slated for launch on July 26, 1996 to observe and record a high-resolution (approx. 2 A FWHM) EUV spectrum of the planet Venus. These preparations were designed to improve the spectral resolution and sensitivity performance of the EUVS payload as well as prepare the payload for this upcoming mission. The following is a list of the EUVS project activities that have taken place since the beginning of this CY: (1) Applied a fresh, new SiC optical coating to our existing 2400 groove/mm grating to boost its reflectivity; (2) modified the Ranicon science detector to boost its detective quantum efficiency with the addition of a repeller grid; (3) constructed a new entrance slit plane to achieve 2 A FWHM spectral resolution; (4) prepared and held the Payload Initiation Conference (PIC) with the assigned NASA support team from Wallops Island for the upcoming 36.148CL flight (PIC held on March 8, 1996; see Attachment A); (5) began wavelength calibration activities of EUVS in the laboratory; (6) made arrangements for travel to WSMR to begin integration activities in preparation for the July 1996 launch; (7) paper detailing our previous EUVS Venus mission (NASA flight 36.117CL) published in Icarus (see Attachment B); and (8) continued data analysis of the previous EUVS mission 36.137CL (Spica occultation flight).

  14. Sound Clocks and Sonic Relativity

    Science.gov (United States)

    Todd, Scott L.; Menicucci, Nicolas C.

    2017-10-01

    Sound propagation within certain non-relativistic condensed matter models obeys a relativistic wave equation despite such systems admitting entirely non-relativistic descriptions. A natural question that arises upon consideration of this is, "do devices exist that will experience the relativity in these systems?" We describe a thought experiment in which `acoustic observers' possess devices called sound clocks that can be connected to form chains. Careful investigation shows that appropriately constructed chains of stationary and moving sound clocks are perceived by observers on the other chain as undergoing the relativistic phenomena of length contraction and time dilation by the Lorentz factor, γ , with c the speed of sound. Sound clocks within moving chains actually tick less frequently than stationary ones and must be separated by a shorter distance than when stationary to satisfy simultaneity conditions. Stationary sound clocks appear to be length contracted and time dilated to moving observers due to their misunderstanding of their own state of motion with respect to the laboratory. Observers restricted to using sound clocks describe a universe kinematically consistent with the theory of special relativity, despite the preferred frame of their universe in the laboratory. Such devices show promise in further probing analogue relativity models, for example in investigating phenomena that require careful consideration of the proper time elapsed for observers.

  15. Fourth sound of holographic superfluids

    International Nuclear Information System (INIS)

    Yarom, Amos

    2009-01-01

    We compute fourth sound for superfluids dual to a charged scalar and a gauge field in an AdS 4 background. For holographic superfluids with condensates that have a large scaling dimension (greater than approximately two), we find that fourth sound approaches first sound at low temperatures. For condensates that a have a small scaling dimension it exhibits non-conformal behavior at low temperatures which may be tied to the non-conformal behavior of the order parameter of the superfluid. We show that by introducing an appropriate scalar potential, conformal invariance can be enforced at low temperatures.

  16. Incidental Learning of Sound Categories is Impaired in Developmental Dyslexia

    Science.gov (United States)

    Gabay, Yafit; Holt, Lori L.

    2015-01-01

    Developmental dyslexia is commonly thought to arise from specific phonological impairments. However, recent evidence is consistent with the possibility that phonological impairments arise as symptoms of an underlying dysfunction of procedural learning. The nature of the link between impaired procedural learning and phonological dysfunction is unresolved. Motivated by the observation that speech processing involves the acquisition of procedural category knowledge, the present study investigates the possibility that procedural learning impairment may affect phonological processing by interfering with the typical course of phonetic category learning. The present study tests this hypothesis while controlling for linguistic experience and possible speech-specific deficits by comparing auditory category learning across artificial, nonlinguistic sounds among dyslexic adults and matched controls in a specialized first-person shooter videogame that has been shown to engage procedural learning. Nonspeech auditory category learning was assessed online via within-game measures and also with a post-training task involving overt categorization of familiar and novel sound exemplars. Each measure reveals that dyslexic participants do not acquire procedural category knowledge as effectively as age- and cognitive-ability matched controls. This difference cannot be explained by differences in perceptual acuity for the sounds. Moreover, poor nonspeech category learning is associated with slower phonological processing. Whereas phonological processing impairments have been emphasized as the cause of dyslexia, the current results suggest that impaired auditory category learning, general in nature and not specific to speech signals, could contribute to phonological deficits in dyslexia with subsequent negative effects on language acquisition and reading. Implications for the neuro-cognitive mechanisms of developmental dyslexia are discussed. PMID:26409017

  17. Incidental learning of sound categories is impaired in developmental dyslexia.

    Science.gov (United States)

    Gabay, Yafit; Holt, Lori L

    2015-12-01

    Developmental dyslexia is commonly thought to arise from specific phonological impairments. However, recent evidence is consistent with the possibility that phonological impairments arise as symptoms of an underlying dysfunction of procedural learning. The nature of the link between impaired procedural learning and phonological dysfunction is unresolved. Motivated by the observation that speech processing involves the acquisition of procedural category knowledge, the present study investigates the possibility that procedural learning impairment may affect phonological processing by interfering with the typical course of phonetic category learning. The present study tests this hypothesis while controlling for linguistic experience and possible speech-specific deficits by comparing auditory category learning across artificial, nonlinguistic sounds among dyslexic adults and matched controls in a specialized first-person shooter videogame that has been shown to engage procedural learning. Nonspeech auditory category learning was assessed online via within-game measures and also with a post-training task involving overt categorization of familiar and novel sound exemplars. Each measure reveals that dyslexic participants do not acquire procedural category knowledge as effectively as age- and cognitive-ability matched controls. This difference cannot be explained by differences in perceptual acuity for the sounds. Moreover, poor nonspeech category learning is associated with slower phonological processing. Whereas phonological processing impairments have been emphasized as the cause of dyslexia, the current results suggest that impaired auditory category learning, general in nature and not specific to speech signals, could contribute to phonological deficits in dyslexia with subsequent negative effects on language acquisition and reading. Implications for the neuro-cognitive mechanisms of developmental dyslexia are discussed. Copyright © 2015 Elsevier Ltd. All rights

  18. Sound intensity as a function of sound insulation partition

    OpenAIRE

    Cvetkovic , S.; Prascevic , R.

    1994-01-01

    In the modern engineering practice, the sound insulation of the partitions is the synthesis of the theory and of the experience acquired in the procedure of the field and of the laboratory measurement. The science and research public treat the sound insulation in the context of the emission and propagation of the acoustic energy in the media with the different acoustics impedance. In this paper, starting from the essence of physical concept of the intensity as the energy vector, the authors g...

  19. An Integrated Approach to Motion and Sound

    National Research Council Canada - National Science Library

    Hahn, James K; Geigel, Joe; Lee, Jong W; Gritz, Larry; Takala, Tapio; Mishra, Suneil

    1995-01-01

    Until recently, sound has been given little attention in computer graphics and related domains of computer animation and virtual environments, although sounds which are properly synchronized to motion...

  20. Evaluating the construct of triage acuity against a set of reference vignettes developed via modified Delphi method.

    Science.gov (United States)

    Twomey, Michèle; Wallis, Lee A; Myers, Jonathan E

    2014-07-01

    To evaluate the construct of triage acuity as measured by the South African Triage Scale (SATS) against a set of reference vignettes. A modified Delphi method was used to develop a set of reference vignettes. Delphi participants completed a 2-round consensus-building process, and independently assigned triage acuity ratings to 100 written vignettes unaware of the ratings given by others. Triage acuity ratings were summarised for all vignettes, and only those that reached 80% consensus during round 2 were included in the reference set. Triage ratings for the reference vignettes given by two independent experts using the SATS were compared with the ratings given by the international Delphi panel. Measures of sensitivity, specificity, associated percentages for over-triage/under-triage were used to evaluate the construct of triage acuity (as measured by the SATS) by examining the association between the ratings by the two experts and the international panel. On completion of the Delphi process, 42 of the 100 vignettes reached 80% consensus on their acuity rating and made up the reference set. On average, over all acuity levels, sensitivity was 74% (CI 64% to 82%), specificity 92% (CI 87% to 94%), under-triage occurred 14% (CI 8% to 23%) and over-triage 12% (CI 8% to 23%) of the time. The results of this study provide an alternative to evaluating triage scales against the construct of acuity as measured with the SATS. This method of using 80% consensus vignettes may, however, systematically bias the validity estimate towards better performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Improvement of visual acuity and VEP after optic nerve contusion by NGF and its safety analysis

    Directory of Open Access Journals (Sweden)

    Ming Zhao

    2018-02-01

    Full Text Available AIM:To investigate the effect of neuropathic factor(NGFon visual acuity and visual evoked potential(VEPin patients with optic nerve contusion. METHODS:Totally 78 patients(78 eyeswith optic nerve contusion were selected. From January 2013 to June 2016, 39 cases(39 eyeswere divided into observation group and control group respectively according to the random number table method. Prednisone, vitamins and mecobalamin tablets treatment were given to both groups, based on that, the observation group was given NGF treatment, continuous treatment of 2 courses(21d for a course of treatment. RESULTS: There was no significant difference in visual field defect and visual field sensitivity between the observation group and the control group before treatment(P>0.05. After treatment, the visual field defect degree of the observation group was smaller, the visual field sensitivity was better than that of the control group(PP>0.05. After treatment, the P100 wave latency of the observation group was significantly shorter than that of the control group(PPPCONCLUSION: NGF treatment for optic nerve contusion can significantly improve the patient's visual acuity, VEP indicators, reduce visual field defects, improve visual field sensitivity.

  2. The Joint Effects of Spatial Cueing and Transcranial Direct Current Stimulation on Visual Acuity

    Directory of Open Access Journals (Sweden)

    Taly Bonder

    2018-02-01

    Full Text Available The present study examined the mutual influence of cortical neuroenhancement and allocation of spatial attention on perception. Specifically, it explored the effects of transcranial Direct Current Stimulation (tDCS on visual acuity measured with a Landolt gap task and attentional precues. The exogenous cues were used to draw attention either to the location of the target or away from it, generating significant performance benefits and costs. Anodal tDCS applied to posterior occipital area for 15 min improved performance during stimulation, reflecting heightened visual acuity. Reaction times were lower, and accuracy was higher in the tDCS group, compared to a sham control group. Additionally, in post-stimulation trials tDCS significantly interacted with the effect of precuing. Reaction times were lower in valid cued trials (benefit and higher in invalid trials (cost compared to neutrally cued trials, the effect which was pronounced stronger in tDCS group than in sham control group. The increase of cost and benefit effects in the tDCS group was of a similar magnitude, suggesting that anodal tDCS influenced the overall process of attention orienting. The observed interaction between the stimulation of the visual cortex and precueing indicates a magnification of attention modulation.

  3. Visual Acuity Improvement of Amblyopia in an Adult With Levodopa/Carbidopa Treatment.

    Science.gov (United States)

    Orge, Faruk H; Dar, Suhail A

    2015-09-09

    Amblyopia is the leading cause of visual loss in children, affecting 2% to 3% of the population. Occlusion of the dominant eye is the primary and best treatment, although efficacy decreases after 6 years of age. As a result, levodopa/carbidopa has been explored as an adjunct to conventional therapy and has been shown to have an immediate impact on visual acuity. Several studies to date have shown mixed results on the benefit of supplementing occlusion therapy with levodopa/carbidopa, although they have primarily studied children. The authors describe the oldest patient (46 years old) documented in the literature to have shown improvement in visual acuity using levodopa/carbidopa. He was given a 16-week course at a dose in line with previous studies while being effectively occluded full time due to a glaucomatous right eye with no light perception. On 3-month follow-up, his left eye improved two lines and stabilized at 6 months. Copyright 2015, SLACK Incorporated.

  4. Taste acuity, plasma zinc levels, and weight loss during radiotherapy: a study of relationships

    International Nuclear Information System (INIS)

    Bolze, M.S.; Fosmire, G.J.; Stryker, J.A.; Chung, C.K.; Flipse, B.G.

    1982-01-01

    Thirty-five patients who were to undergo radiotherapy and 13 normal subjects were evaluated with taste questionnaires, taste acuity tests, and plasma zinc analyses. The studies were repeated on the patients in the fifth week of radiotherapy. The mean taste thresholds for NaCl (salt), sucrose (sweet), HCl (sour), and urea (bitter) were elevated and the plasma zinc levels were lower (77.2 +/- 11.8 vs. 94.6 +/- 30.1 g/100 ml, p . 0.055) for the patients than for the controls. However, there was not a significant correlation between the taste thresholds and plasma zinc levels at any time. The mean weight loss experienced by the 14 patients who reported subjective taste alteration in the fifth week was 3.1 kg versus 0.1 kg (p . 0.005) for those who did not report taste alteration. The data suggest that alterations in taste acuity, but not plasma zinc levels, are associated with weight loss during radiotherapy

  5. Taste acuity, plasma zinc levels, and weight loss during radiotherapy: a study of relationships

    International Nuclear Information System (INIS)

    Bolze, M.S.; Fosmire, G.J.; Stryker, J.A.; Chung, C.K.; Flipse, B.G.

    1982-01-01

    Thirty-five patients who were to undergo radiotherapy and 13 normal subjects were evaluated with taste questionnaires, taste acuity tests, and plasma zinc analyses. The studies were repeated on the patients in the fifth week of radiotherapy. The mean taste thresholds for NaCl (salt), sucrose (sweet), HCl (sour), and urea (bitter) were elevated and the plasma zinc levels were lower (77.2 +/- 11.8 vs. 94.6 +/- 30.1 g/100 ml, p = 0.055) for the patients than for the controls. However, there was not a significant correlation between the taste thresholds and plasma zinc levels at any time. The mean weight loss experienced by the 14 patients who reported subjective taste alteration in the fifth week was 3.1 kg versus 0.1 kg (p = 0.005) for those who did not report taste alteration. The data suggest that alterations in taste acuity, but not plasma zinc levels, are associated with weight loss during radiotherapy

  6. The science of sound recording

    CERN Document Server

    Kadis, Jay

    2012-01-01

    The Science of Sound Recording will provide you with more than just an introduction to sound and recording, it will allow you to dive right into some of the technical areas that often appear overwhelming to anyone without an electrical engineering or physics background.  The Science of Sound Recording helps you build a basic foundation of scientific principles, explaining how recording really works. Packed with valuable must know information, illustrations and examples of 'worked through' equations this book introduces the theory behind sound recording practices in a logical and prac

  7. Gefinex 400S (Sampo) EM-Soundings at Olkiluoto 2007

    International Nuclear Information System (INIS)

    Jokinen, T.; Lehtimaeki, J.

    2007-09-01

    In the beginning of June 2007 Geological Survey of Finland carried out electromagnetic frequency soundings with Gefinex 400S equipment (Sampo) at Onkalo situated in Olkiluoto nuclear power plant area. The same soundings sites were the first time measured and marked in 2004 and repeated after it yearly. The aim of the measurements is to monitor the changes of groundwater conditions by the changes of the electric conductivity of the earth at ONKALO and repository area. The measurements form two 1400 m long broadside profiles, which have 200 m mutual distance and 200 m station separation. The profiles have been measured using 200, 500, and 800 m coil separations. The total number of the soundings stations is 48. In 2007 at 8 sounding stations the transmitter and/or receiver sites were changed and the line L11.400 was substituted by line L11.500. Some changes helped but anyway there were 6 stations that could not be measured because of the strong electromagnetic noise. The numerous power lines and the cables of the area generate local 3-D effects on the sounding curves, but the repeatability of the results is good. However, most suitable for monitoring purposes are the sites without strong 3-D effects. Comparison of results 2004-2007 shows small differences at some sounding sites. (orig.)

  8. Boundary stabilization of memory-type thermoelasticity with second sound

    Science.gov (United States)

    Mustafa, Muhammad I.

    2012-08-01

    In this paper, we consider an n-dimensional thermoelastic system of second sound with a viscoelastic damping localized on a part of the boundary. We establish an explicit and general decay rate result that allows a wider class of relaxation functions and generalizes previous results existing in the literature.

  9. A comparison of Lea Symbol vs ETDRS letter distance visual acuity in a population of young children with a high prevalence of astigmatism.

    Science.gov (United States)

    Dobson, Velma; Clifford-Donaldson, Candice E; Miller, Joseph M; Garvey, Katherine A; Harvey, Erin M

    2009-06-01

    To compare visual acuity results obtained by use of the Lea Symbols chart with results obtained with Early Treatment Diabetic Retinopathy Study (ETDRS) charts in young children who are members of a population with a high prevalence of astigmatism. Subjects were 438 children ages 5 through 7 years who were enrolled in kindergarten or first grade on the Tohono O'odham Reservation: 241 (55%) had astigmatism >or=1.00 D in one or both eyes (range, 0.00-6.75 D). While wearing best correction, each child had right eye visual acuity tested with the 62 cm by 65 cm Lea Symbols chart at 3 m and with the 62 cm by 65 cm ETDRS chart at 4 m. Visual acuity was scored as the smallest optotype size at which the child correctly identified 3 of a maximum of 5 optotypes. ETDRS visual acuity also was scored based on the total number of letters that the child correctly identified. Correlation between Lea Symbols visual acuity and ETDRS visual acuity was 0.78 (p < 0.001). Mean Lea Symbols visual acuity was one-half line (0.04-0.06 logMAR) better than mean ETDRS visual acuity (p < 0.001). The difference between Lea Symbols and ETDRS visual acuity was not correlated with the mean of the Lea Symbols and ETDRS visual acuity scores, which ranged from -0.3 logMAR (20/10) to 0.74 logMAR (20/110). In this population of young children, in whom the primary source of reduced visual acuity is astigmatism-related amblyopia, the Lea Symbols chart produced visual acuity scores that were about 0.5 line better than visual acuity scores obtained with ETDRS charts.

  10. Visualization of Broadband Sound Sources

    OpenAIRE

    Sukhanov Dmitry; Erzakova Nadezhda

    2016-01-01

    In this paper the method of imaging of wideband audio sources based on the 2D microphone array measurements of the sound field at the same time in all the microphones is proposed. Designed microphone array consists of 160 microphones allowing to digitize signals with a frequency of 7200 Hz. Measured signals are processed using the special algorithm that makes it possible to obtain a flat image of wideband sound sources. It is shown experimentally that the visualization is not dependent on the...

  11. The correlation between variation of visual acuity and the anterior chamber depth in the early period after phacoemulsification

    Directory of Open Access Journals (Sweden)

    Kai-jian CHEN

    2011-04-01

    Full Text Available Objective To investigate the correlation between the visual acuity variation and the anterior chamber depth in the early period after phacoemulsification.Methods Thirty-six eyes of 32 patients with age-related cataract underwent 3.2mm clear corneal incision phacoemulsification and intraocular lens(IOL implantation.The visual acuity was examined and horizontal curvature(K1,vertical curvature(K2,corneal astigmatism,and anterior chamber depth were measured with IOL-master preoperatively and also on 1,3,7 and 15 postoperative days.The changes in parameters were compared,and the correlations among visual acuity,corneal astigmatism and anterior chamber depth were analyzed.Results Before operation and 1d,3d,7d and 15d after operation,the corneal astigmatism was-0.87±0.40D,-1.92±1.38D,-1.69±1.13D,-1.45±0.79D and-1.36±0.74D;the anterior chamber depth was 3.08±0.35mm,4.04±0.38mm,4.28±0.29mm,4.22±0.17mm and 4.22±0.16mm;the visual acuity was 0.18±0.10,0.44±0.14,0.59±0.12,0.61±0.11 and 0.62±0.14.Significant difference was found between pre-operative and postoperative visual acuity,corneal astigmatism and anterior chamber depth,and it was also found in corneal astigmatism between 1d and 15d post operation(P < 0.05,as well as in anterior chamber depth and visual acuity between 1d and 3d post operation(P < 0.05.A positive correlation was found between visual acuity and corneal astigmatism on 1d(r=0.42,P < 0.05,3d(r=0.35,P < 0.05 and 7d(r=0.35,P < 0.05 post operation;and a negative correlation was found between visual acuity and anterior chamber depth on 3d(r=-0.29,P < 0.05,7d(r=-0.43,P < 0.01 and 15d(r=-0.37,P < 0.05 post operation.Conclusion Both the corneal astigmatism and the anterior chamber depth are correlated with the visual acuity variation in the early period after phacoemulsification.

  12. A comparison of static near stereo acuity in youth baseball/softball players and non-ball players.

    Science.gov (United States)

    Boden, Lauren M; Rosengren, Kenneth J; Martin, Daniel F; Boden, Scott D

    2009-03-01

    Although many aspects of vision have been investigated in professional baseball players, few studies have been performed in developing athletes. The issue of whether youth baseball players have superior stereopsis to nonplayers has not been addressed specifically. The purpose of this study was to determine if youth baseball/softball players have better stereo acuity than non-ball players. Informed consent was obtained from 51 baseball/softball players and 52 non-ball players (ages 10 to 18 years). Subjects completed a questionnaire, and their static near stereo acuity was measured using the Randot Stereotest (Stereo Optical Company, Chicago, Illinois). Stereo acuity was measured as the seconds of arc between the last pair of images correctly distinguished by the subject. The mean stereo acuity score was 25.5 +/- 1.7 seconds of arc in the baseball/softball players and 56.2 +/- 8.4 seconds of arc in the non-ball players. This difference was statistically significant (P softball players had significantly better static stereo acuity than non-ball players, comparable to professional ball players.

  13. [Amblyopia: reading speed in comparison with visual acuity for gratings, single Landolt Cs and series Landolt Cs].

    Science.gov (United States)

    Bach, M; Strahl, P; Waltenspiel, S; Kommerell, G

    1990-01-01

    In the treatment of amblyopia in preschool children, a means of predicting later reading ability would be helpful. This prediction might be possible using a test for visual acuity where the results correlate with reading ability in adult patients with amblyopia. We measured the following four parameters in 18 experienced readers with strabismic amblyopia: (1) time spent reading ten lines of a standard text in one of three magnifications, (2) visual acuity for gratings, (3) visual acuity for single Landolt Cs, and (4) visual acuity for crowded Landolt Cs (one Landolt C flanked by two full rings on each side each at a distance of 2.6 min of arc). The reading text was presented on paper at a distance of 40 cm; the subject had a choice of three magnifications. The acuity tests were generated by a computer on a VDU at 4.6 m. The relative impairment of the amblyopic eye was defined as the quotient between the performance of the amblyopic and the good eye. In addition, the difference between the times spent reading the ten lines with the amblyopic and with the good eye was calculated.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Posttreatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanomas: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    2002-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque (Collaborative Ocular Melanoma Study [COMS] design) application for the treatment of choroidal melanoma. The mean tumor height was 4.5 mm (range 1.7-8.3). Doses and dose rates at the tumor apex, macula, and optic disc were calculated. Forty-three records were scored to assess whether a decrease in visual acuity of >2 lines on a standard Snellen eye chart had occurred. Patient age and the presence of hypertension or diabetes were noted. Statistical analysis was performed to assess both the rate at which visual decline had occurred and the presence of significant factors that had contributed to this decline. Results: With a median follow-up of 36 months, the 3-year actuarial survival rate was 93.6%. The 3-year actuarial local control rate was 86.9%. The median time to visual loss after therapy was 18.7 months. The 3-year actuarial rate of visual preservation was 40.5%. Multivariate analysis demonstrated higher macula dose rates (p=0.003) to forecast visual decline. Macula dose rates of 111±11.1 cGy/h were associated with a 50% risk of significant visual loss. Conclusion: Patients in our series treated with 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of visual decline. Higher dose rates to the macula correlated strongly with poorer posttreatment visual outcome. This information may be valuable in selecting the optimal dose rates to treat choroidal melanomas and to predict the risk of visual decline

  15. Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity.

    Science.gov (United States)

    Koefoed, Vilhelm F; Baste, Valborg; Roumes, Corinne; Høvding, Gunnar

    2015-03-01

    This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.

  16. 27 CFR 9.151 - Puget Sound.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Puget Sound. 9.151 Section... Sound. (a) Name. The name of the viticultural area described in this section is “Puget Sound.” (b) Approved maps. The appropriate maps for determining the boundary of the Puget Sound viticultural area are...

  17. Seismic and Biological Sources of Ambient Ocean Sound

    Science.gov (United States)

    Freeman, Simon Eric

    Sound is the most efficient radiation in the ocean. Sounds of seismic and biological origin contain information regarding the underlying processes that created them. A single hydrophone records summary time-frequency information from the volume within acoustic range. Beamforming using a hydrophone array additionally produces azimuthal estimates of sound sources. A two-dimensional array and acoustic focusing produce an unambiguous two-dimensional `image' of sources. This dissertation describes the application of these techniques in three cases. The first utilizes hydrophone arrays to investigate T-phases (water-borne seismic waves) in the Philippine Sea. Ninety T-phases were recorded over a 12-day period, implying a greater number of seismic events occur than are detected by terrestrial seismic monitoring in the region. Observation of an azimuthally migrating T-phase suggests that reverberation of such sounds from bathymetric features can occur over megameter scales. In the second case, single hydrophone recordings from coral reefs in the Line Islands archipelago reveal that local ambient reef sound is spectrally similar to sounds produced by small, hard-shelled benthic invertebrates in captivity. Time-lapse photography of the reef reveals an increase in benthic invertebrate activity at sundown, consistent with an increase in sound level. The dominant acoustic phenomenon on these reefs may thus originate from the interaction between a large number of small invertebrates and the substrate. Such sounds could be used to take census of hard-shelled benthic invertebrates that are otherwise extremely difficult to survey. A two-dimensional `map' of sound production over a coral reef in the Hawaiian Islands was obtained using two-dimensional hydrophone array in the third case. Heterogeneously distributed bio-acoustic sources were generally co-located with rocky reef areas. Acoustically dominant snapping shrimp were largely restricted to one location within the area surveyed

  18. Sounds of a Star

    Science.gov (United States)

    2001-06-01

    Acoustic Oscillations in Solar-Twin "Alpha Cen A" Observed from La Silla by Swiss Team Summary Sound waves running through a star can help astronomers reveal its inner properties. This particular branch of modern astrophysics is known as "asteroseismology" . In the case of our Sun, the brightest star in the sky, such waves have been observed since some time, and have greatly improved our knowledge about what is going on inside. However, because they are much fainter, it has turned out to be very difficult to detect similar waves in other stars. Nevertheless, tiny oscillations in a solar-twin star have now been unambiguously detected by Swiss astronomers François Bouchy and Fabien Carrier from the Geneva Observatory, using the CORALIE spectrometer on the Swiss 1.2-m Leonard Euler telescope at the ESO La Silla Observatory. This telescope is mostly used for discovering exoplanets (see ESO PR 07/01 ). The star Alpha Centauri A is the nearest star visible to the naked eye, at a distance of a little more than 4 light-years. The new measurements show that it pulsates with a 7-minute cycle, very similar to what is observed in the Sun . Asteroseismology for Sun-like stars is likely to become an important probe of stellar theory in the near future. The state-of-the-art HARPS spectrograph , to be mounted on the ESO 3.6-m telescope at La Silla, will be able to search for oscillations in stars that are 100 times fainter than those for which such demanding observations are possible with CORALIE. PR Photo 23a/01 : Oscillations in a solar-like star (schematic picture). PR Photo 23b/01 : Acoustic spectrum of Alpha Centauri A , as observed with CORALIE. Asteroseismology: listening to the stars ESO PR Photo 23a/01 ESO PR Photo 23a/01 [Preview - JPEG: 357 x 400 pix - 96k] [Normal - JPEG: 713 x 800 pix - 256k] [HiRes - JPEG: 2673 x 3000 pix - 2.1Mb Caption : PR Photo 23a/01 is a graphical representation of resonating acoustic waves in the interior of a solar-like star. Red and blue

  19. Parafoveal magnification: visual acuity does not modulate the perceptual span in reading.

    Science.gov (United States)

    Miellet, Sébastien; O'Donnell, Patrick J; Sereno, Sara C

    2009-06-01

    Models of eye guidance in reading rely on the concept of the perceptual span-the amount of information perceived during a single eye fixation, which is considered to be a consequence of visual and attentional constraints. To directly investigate attentional mechanisms underlying the perceptual span, we implemented a new reading paradigm-parafoveal magnification (PM)-that compensates for how visual acuity drops off as a function of retinal eccentricity. On each fixation and in real time, parafoveal text is magnified to equalize its perceptual impact with that of concurrent foveal text. Experiment 1 demonstrated that PM does not increase the amount of text that is processed, supporting an attentional-based account of eye movements in reading. Experiment 2 explored a contentious issue that differentiates competing models of eye movement control and showed that, even when parafoveal information is enlarged, visual attention in reading is allocated in a serial fashion from word to word.

  20. Quality of life and visual acuity outcomes in the Registry in Glaucoma Outcomes Research study.

    Science.gov (United States)

    Coleman, Anne L; Lum, Flora C; Gliklich, Richard E; Velentgas, Priscilla; Su, Zhaohui

    2016-01-01

    The RiGOR study evaluated the association of treatment and patient-reported outcomes for open-angle glaucoma patients. The Glaucoma Symptom Scale (National Eye Institute-Visual Function Questionnaire (NEI-VFQ) and visual acuity (VA) were collected as quality of life measures. The proportion of patients with improvement of at least two lines of vision was highest in the incisional surgery group (14.2% compared with 9.9% for laser surgery and 10.9% for additional medication). No clinically relevant differences were seen in benefit for the laser surgery or incisional surgery groups compared with additional medications for the Glaucoma Symptom Scale or NEI-VFQ measures or subscales. Differences in quality of life by race need to be explored in further studies.

  1. The role of visual acuity and segmentation cues in compound word identification

    Directory of Open Access Journals (Sweden)

    Jukka eHyönä

    2012-06-01

    Full Text Available Studies are reviewed that demonstrate how the foveal area of the eye constrains how compound words are identified during reading. When compound words are short, their letters can be identified during a single fixation, leading to the whole-word route dominating word recognition from early on. Hence, visually marking morpheme boundaries by hyphens slows down processing by encouraging morphological decomposition when holistic processing is a feasible option. In contrast, the decomposition route dominates the early stages of identifying long compound words. Thus, visual marking of morpheme boundaries facilitates processing of long compound words, unless the initial fixation made on the word lands very close to the morpheme boundary. The reviewed pattern of results is explained by the visual acuity principle (Bertram & Hyönä, 2003 and the dual-route framework of morphological processing.

  2. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The

  3. Impact of colour in the assessment of potential visual acuity in patients with age-related macular degeneration.

    Science.gov (United States)

    Dorrepaal, Stephen J; Markowitz, Samuel N

    2013-06-01

    To compare chromatic and achromatic potential visual acuity (PVA) in patients with bilateral low vision caused by age-related macular degeneration (AMD). Prospective, nonrandomized, observational case series. Fifty-five patients, representing a consecutive series of patients all presenting with bilateral AMD. Best-corrected visual acuity of each eye was measured using an Early Treatment in Diabetic Retinopathy Study (ETDRS) chart with appropriate near correction. Included were cases with visual acuity of 0.4 logMAR (20/50) or worse in both eyes. Achromatic and chromatic PVA were measured in each eye using white on black and red on yellow flooding E charts at 50 cm in controlled lighting conditions. One hundred and seven eyes from 55 patients were included in the analysis. Mean achromatic and chromatic PVA were 0.69 ± 0.26 and 0.65 ± 0.22 logMAR, respectively. Overall, patients had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity worse than 0.9 logMAR also had a significantly higher chromatic than achromatic PVA, with a median difference of 0.1 logMAR (p<0.05). Patients with ETDRS visual acuity between 0.4 and 0.9 logMAR had a trend toward a higher chromatic than achromatic visual acuity that was not significant, with a median difference of 0.1 logMAR (p = 0.8539). Patients with low vision caused by AMD can discern smaller targets when a red on yellow colour scheme is used than when using achromatic white on black charts. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  4. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors.

    Science.gov (United States)

    Yazar, Seyhan; Hewitt, Alex W; Forward, Hannah; McKnight, Charlotte M; Tan, Alex; Mountain, Jenny A; Mackey, David A

    2014-03-01

    To compare the monochromatic aberrations in a large cohort of 20-year-old Australians with differing levels of visual acuity and explore the relationship between these aberrations and refractive error. Lions Eye Institute, Perth, Western Australia, Australia. Cross-sectional analysis of a population-based cohort. Monochromatic aberrations were measured using a Zywave II wavefront aberrometer with natural pupils in a dark room. The logMAR corrected distance visual acuity (CDVA) was measured monocularly under normal illumination. Cycloplegic autorefraction was also performed. The study enrolled 2039 eyes of 1040 participants. Data from 1007 right eyes were analyzed. The median CDVA and spherical equivalent were -0.06 logMAR (interquartile range [IQR], -0.10 to 0.00) and +0.25 diopters (D) (IQR, -0.38 to 0.63), respectively. The median 6.0 mm higher-order aberration (HOA) was 0.58 μm (IQR, 0.44 to 0.79). Coma-like aberrations and 3rd-, 4th-, and 5th-order HOAs were significantly different between subjects with a CDVA of -0.10 logMAR or better and those with a CDVA worse than -0.10 logMAR. Fourth-order aberrations Z(4,-4) (P=.024) and Z(4,-2) (P=.029) and 2nd-order aberration Z(2,0) (Peyes, emmetropic eyes, and hyperopic eyes. Subjects with higher myopia had slightly higher total HOAs. The HOAs in this population were marginally higher than previously reported values. The findings confirm there is a difference in monochromatic aberrations between different vision and refractive groups. Results in this study will benefit decision-making processes in the clinical setting. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. A cross-sectional examination of visual acuity by specific type of albinism.

    Science.gov (United States)

    Winsor, Caitlin Nosanov; Holleschau, Ann M; Connett, John E; Summers, C Gail

    2016-10-01

    Reports of best-corrected visual acuity (BCVA) in albinism are often based on overlapping clinical phenotypes. BCVA in albinism has been shown to improve with age. This study reports a large cross-sectional investigation to determine whether BCVA differs by specific type of albinism when age-corrected. This retrospective review identified 170 individuals with a specific type of albinism identified by mutation(s) in a gene known to cause albinism (for OCA1, OCA2, and Hermansky-Pudlak syndrome ([HPS]) or a specific phenotype (white hair and no melanin pigment in OCA1A; pigmentary mosaicism in the obligate carriers for males with OA1). We recorded optotype binocular BCVA at final follow-up. Patients were age-grouped (2-5 years, 6-14 years, and ≥15 years) for comparison. The greatest visual acuity deficit was found for OCA1A in all age groups. At age ≥15 years (n = 79), mean BCVA was 20/128 for OCA1A, 20/37 for OCA1B, 20/59 for OCA2, 20/63 for OA1, and 20/121 for HPS. Significant differences between BCVA at ≥15 years were found in the following: OCA1A vs OCA1B, OCA1A vs OCA2, OCA1A vs OA1, OCA1B vs HPS, OCA2 vs HPS, and OA1 vs HPS (P ≤ 0.02). This study provides a large sample size and includes only those with a specific type of albinism. BCVA varies by albinism type, and there is overlap in BCVA, particularly in the younger age groups. For ages ≥15 years, there are significant differences in BCVA between several types of albinism. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  6. Using the Freiburg Acuity and Contrast Test to measure visual performance in USAF personnel after PRK.

    Science.gov (United States)

    Dennis, Richard J; Beer, Jeremy M A; Baldwin, J Bruce; Ivan, Douglas J; Lorusso, Frank J; Thompson, William T

    2004-07-01

    Photorefractive keratectomy (PRK) may be an alternative to spectacle and contact lens wear for United States Air Force (USAF) aircrew and may offer some distinct advantages in operational situations. However, any residual corneal haze or scar formation from PRK could exacerbate the disabling effects of a bright glare source on a complex visual task. The USAF recently completed a longitudinal clinical evaluation of the long-term effects of PRK on visual performance, including the experiment described herein. After baseline data were collected, 20 nonflying active duty USAF personnel underwent PRK. Visual performance was then measured at 6, 12, and 24 months after PRK. Visual acuity (VA) and contrast sensitivity (CS) data were collected by using the Freiburg Acuity and Contrast Test (FrACT), with the subject viewing half of the runs through a polycarbonate windscreen. Experimental runs were completed under 3 glare conditions: no glare source and with either a broadband or a green laser (532-nm) glare annulus (luminance approximately 6090 cd/m) surrounding the Landolt C stimulus. Systematic effects of PRK on VA relative to baseline were not identified. However, VA was almost 2 full Snellen lines worse with the laser glare source in place versus the broadband glare source. A significant drop-off was observed in CS performance after PRK under conditions of no glare and broadband glare; this was the case both with and without the windscreen. As with VA, laser glare disrupted CS performance significantly and more than broadband glare did. PRK does not appear to have affected VA, but the changes in CS might represent a true decline in visual performance. The greater disruptive effects from laser versus broadband glare may be a result of increased masking from coherent spatial noise (speckle) surrounding the laser stimulus.

  7. Visual acuity and refraction by age for children of three different ethnic groups in Paraguay

    Directory of Open Access Journals (Sweden)

    Marissa Janine Carter

    2013-04-01

    Full Text Available PURPOSE: To characterize refractive errors in Paraguayan children aged 5-16 years and investigate effect of age, gender, and ethnicity. METHODS:The study was conducted at 3 schools that catered to Mennonite, indigenous, and mixed race children. Children were examined for presenting visual acuity, autorefraction with and without cycloplegia, and retinoscopy. Data were analyzed for myopia and hyperopia (SE ≤-1 D or -0.5 D and ≥2 D or ≥3 D and astigmatism (cylinder ≥1 D. Spherical equivalent (SE values were calculated from right eye cycloplegic autorefraction data and analyzed using general linear modelling. RESULTS: There were 190, 118, and 168 children of Mennonite, indigenous and mixed race ethnicity, respectively. SE values between right/left eyes were nonsignificant. Mean visual acuity (VA without correction was better for Mennonites compared to indigenous or mixed race children (right eyes: 0.031, 0.090, and 0.102 logMAR units, respectively; P<0.000001. There were 2 cases of myopia in the Mennonite group (1.2% and 2 cases in the mixed race group (1.4% (SE ≤-0.5 D. The prevalence of hyperopia (SE ≥2 D was 40.6%, 34.2%, and 46.3% for Mennonite, indigenous and mixed race children. Corresponding astigmatism rates were 3.2%, 9.5%, and 12.7%. Females were slightly more hyperopic than males, and the 9-11 years age group was the most hyperopic. Mennonite and mixed race children were more hyperopic than indigenous children. CONCLUSIONS: Paraguayan children were remarkably hyperopic and relatively free of myopia. Differences with regard to gender, age, and ethnicity were small.

  8. Hearing acuity as a predictor of walking difficulties in older women.

    Science.gov (United States)

    Viljanen, Anne; Kaprio, Jaakko; Pyykkö, Ilmari; Sorri, Martti; Koskenvuo, Markku; Rantanen, Taina

    2009-12-01

    To examine whether hearing acuity correlates with walking ability and whether impaired hearing at baseline predicts new self-reported walking difficulties after 3 years. Prospective follow-up. Research laboratory and community. Four hundred thirty-four women aged 63 to 76. Hearing was measured using clinical audiometry. A person was defined as having a hearing impairment if a pure-tone average of thresholds at 0.5 to 4 kHz in the better ear was 21 dB or greater. Maximal walking speed was measured over 10 m (m/s), walking endurance as the distance (m), covered in 6 minutes and difficulties in walking 2 km according to self-report. At baseline, women with hearing impairment (n=179) had slower maximal walking speed (1.7 +/- 0.3 m/s vs 1.8 +/- 0.3 m/s, P=.007), lower walking endurance (520 +/- 75 m vs 536 +/- 75 m, P=.08), and more selfreported major difficulties in walking 2 km (12.8% vs 5.5%, P=.02) than those without hearing impairment. During follow-up, major walking difficulties developed for 33 participants. Women with hearing impairment at baseline had a twice the age-adjusted risk for new walking difficulties as those without hearing impairment (odds ratio=2.04, 95% confidence interval=0.96-4.33). Hearing acuity correlated with mobility, which may be explained by the association between impaired hearing and poor balance and greater risk for falls, both of which underlie decline in mobility. Prevention of hearing loss is not only important for the ability to communicate, but may also have more wide-ranging influences on functional ability.

  9. Sound engineering for diesel engines; Sound Engineering an Dieselmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Enderich, A.; Fischer, R. [MAHLE Filtersysteme GmbH, Stuttgart (Germany)

    2006-07-01

    The strong acceptance for vehicles powered by turbo-charged diesel engines encourages several manufacturers to think about sportive diesel concepts. The approach of suppressing unpleasant noise by the application of distinctive insulation steps is not adequate to satisfy sportive needs. The acoustics cannot follow the engine's performance. This report documents, that it is possible to give diesel-powered vehicles a sportive sound characteristic by using an advanced MAHLE motor-sound-system with a pressure-resistant membrane and an integrated load controlled flap. With this the specific acoustic disadvantages of the diesel engine, like the ''diesel knock'' or a rough engine running can be masked. However, by the application of a motor-sound-system you must not negate the original character of the diesel engine concept, but accentuate its strong torque characteristic in the middle engine speed range. (orig.)

  10. Sound field separation with sound pressure and particle velocity measurements

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn; Leclère, Quentin

    2012-01-01

    separation techniques make it possible to distinguish between outgoing and incoming waves from the two sides, and thus NAH can be applied. In this paper, a separation method based on the measurement of the particle velocity in two layers and another method based on the measurement of the pressure...... and the velocity in a single layer are proposed. The two methods use an equivalent source formulation with separate transfer matrices for the outgoing and incoming waves, so that the sound from the two sides of the array can be modeled independently. A weighting scheme is proposed to account for the distance......In conventional near-field acoustic holography (NAH) it is not possible to distinguish between sound from the two sides of the array, thus, it is a requirement that all the sources are confined to only one side and radiate into a free field. When this requirement cannot be fulfilled, sound field...

  11. Sounds of silence: How to animate virtual worlds with sound

    Science.gov (United States)

    Astheimer, Peter

    1993-01-01

    Sounds are an integral and sometimes annoying part of our daily life. Virtual worlds which imitate natural environments gain a lot of authenticity from fast, high quality visualization combined with sound effects. Sounds help to increase the degree of immersion for human dwellers in imaginary worlds significantly. The virtual reality toolkit of IGD (Institute for Computer Graphics) features a broad range of standard visual and advanced real-time audio components which interpret an object-oriented definition of the scene. The virtual reality system 'Virtual Design' realized with the toolkit enables the designer of virtual worlds to create a true audiovisual environment. Several examples on video demonstrate the usage of the audio features in Virtual Design.

  12. Locating and classification of structure-borne sound occurrence using wavelet transformation

    International Nuclear Information System (INIS)

    Winterstein, Martin; Thurnreiter, Martina

    2011-01-01

    For the surveillance of nuclear facilities with respect to detached or loose parts within the pressure boundary structure-borne sound detector systems are used. The impact of loose parts on the wall causes energy transfer to the wall that is measured a so called singular sound event. The run-time differences of sound signals allow a rough locating of the loose part. The authors performed a finite element based simulation of structure-borne sound measurements using real geometries. New knowledge on sound wave propagation, signal analysis and processing, neuronal networks or hidden Markov models were considered. Using the wavelet transformation it is possible to improve the localization of structure-borne sound events.

  13. Visual acuity loss associated with excessive “dry macula” in exudative age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Takahashi H

    2018-02-01

    Full Text Available Hidenori Takahashi,1–3 Yuji Inoue,1,2 Xue Tan,2,3 Satoru Inoda,1 Shinichi Sakamoto,1 Yusuke Arai,1 Yasuo Yanagi,4–6 Yujiro Fujino,2,3 Hidetoshi Kawashima1 1Department of Ophthalmology, Jichi Medical University, Shimotsuke, 2Department of Ophthalmology, The University of Tokyo, Bunkyo, 3Department of Ophthalmology, Japan Community Health Care Organization Tokyo Shinjuku Medical Center, Shinjuku, Japan; 4Medical Retina, Singapore National Eye Centre, 5Medical Retina, Singapore Eye Research Institute, 6Eye-ACP, Duke NUS Medical School, National University of Singapore, Singapore Purpose: To investigate the correlation between visual acuity and central macular thickness (CMT and choroidal thickness (CCT in patients with wet age-related macular degeneration (AMD. Methods: In this retrospective analysis, 14 eyes that received >10 ranibizumab injections (based on pro re nata [PRN] regimen and maintained initial visual acuity gain were analyzed. The following 5 parameters were measured at the foveal center: CMT (distance from the inner limiting membrane [ILM] to Bruch’s membrane; central retinal thickness (CRT; distance from the ILM to the inner limit of the retinal pigment epithelium or subretinal fluid [SRF]; SRF thickness (SRFT; pigment epithelium detachment thickness (PEDT; and CCT. The correlation between the logarithm of the minimum angle of resolution (logMAR best-corrected visual acuity (BCVA and the 5 parameters was examined with generalized estimating equations. Results: CMT, CRT, and CCT were negatively correlated with logMAR BCVA (P=0.031, 0.023, and 0.036, respectively when only CMT values less than the thickness that maximized visual acuity for each eye were used for the analysis. Each 100-µm reduction in CMT, CRT, or CCT improved logMAR BCVA by -0.1, -0.08, or -0.07, respectively. SRFT and PEDT were not correlated with BCVA. The median CMT that maximized the visual acuity was 230 µm. Conclusion: Dry macula with CMT <230 µm was

  14. Refraction and visual acuity in a national Danish cohort of 4-year-old children of extremely preterm delivery

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Bangsgaard, Regitze; Slidsborg, Carina

    2015-01-01

    PURPOSE: A recent threefold increase in laser treatment for advanced retinopathy of prematurity (ROP) triggered a nationwide preschool ophthalmic and developmental status among extremely preterm survivors. Here, we discuss refraction and visual acuity. METHODS: Survivors (n = 178) from a national...... was 0.1 in FT and 0.2 in PT, in Snellen equivalents 0.8 and 0.63. Snellen acuity ≤0.5 occurred across the ROP subgroups, but mainly in those with at least ROP stage 3. Two children had low vision. CONCLUSIONS: The overall fair outcome for refraction and function is in accordance with other recent...

  15. Mobile sound: media art in hybrid spaces

    OpenAIRE

    Behrendt, Frauke

    2010-01-01

    The thesis explores the relationships between sound and mobility through an examination\\ud of sound art. The research engages with the intersection of sound, mobility and\\ud art through original empirical work and theoretically through a critical engagement with\\ud sound studies. In dialogue with the work of De Certeau, Lefebvre, Huhtamo and Habermas\\ud in terms of the poetics of walking, rhythms, media archeology and questions of\\ud publicness, I understand sound art as an experimental mobil...

  16. 33 CFR 167.1702 - In Prince William Sound: Prince William Sound Traffic Separation Scheme.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false In Prince William Sound: Prince William Sound Traffic Separation Scheme. 167.1702 Section 167.1702 Navigation and Navigable Waters COAST....1702 In Prince William Sound: Prince William Sound Traffic Separation Scheme. The Prince William Sound...

  17. Sounding the field: recent works in sound studies.

    Science.gov (United States)

    Boon, Tim

    2015-09-01

    For sound studies, the publication of a 593-page handbook, not to mention the establishment of at least one society - the European Sound Studies Association - might seem to signify the emergence of a new academic discipline. Certainly, the books under consideration here, alongside many others, testify to an intensification of concern with the aural dimensions of culture. Some of this work comes from HPS and STS, some from musicology and cultural studies. But all of it should concern members of our disciplines, as it represents a long-overdue foregrounding of the aural in how we think about the intersections of science, technology and culture.

  18. Conditioned sounds enhance visual processing.

    Directory of Open Access Journals (Sweden)

    Fabrizio Leo

    Full Text Available This psychophysics study investigated whether prior auditory conditioning influences how a sound interacts with visual perception. In the conditioning phase, subjects were presented with three pure tones ( =  conditioned stimuli, CS that were paired with positive, negative or neutral unconditioned stimuli. As unconditioned reinforcers we employed pictures (highly pleasant, unpleasant and neutral or monetary outcomes (+50 euro cents, -50 cents, 0 cents. In the subsequent visual selective attention paradigm, subjects were presented with near-threshold Gabors displayed in their left or right hemifield. Critically, the Gabors were presented in synchrony with one of the conditioned sounds. Subjects discriminated whether the Gabors were presented in their left or right hemifields. Participants determined the location more accurately when the Gabors were presented in synchrony with positive relative to neutral sounds irrespective of reinforcer type. Thus, previously rewarded relative to neutral sounds increased the bottom-up salience of the visual Gabors. Our results are the first demonstration that prior auditory conditioning is a potent mechanism to modulate the effect of sounds on visual perception.

  19. Moth hearing and sound communication

    DEFF Research Database (Denmark)

    Nakano, Ryo; Takanashi, Takuma; Surlykke, Annemarie

    2015-01-01

    Active echolocation enables bats to orient and hunt the night sky for insects. As a counter-measure against the severe predation pressure many nocturnal insects have evolved ears sensitive to ultrasonic bat calls. In moths bat-detection was the principal purpose of hearing, as evidenced by compar......Active echolocation enables bats to orient and hunt the night sky for insects. As a counter-measure against the severe predation pressure many nocturnal insects have evolved ears sensitive to ultrasonic bat calls. In moths bat-detection was the principal purpose of hearing, as evidenced...... by comparable hearing physiology with best sensitivity in the bat echolocation range, 20–60 kHz, across moths in spite of diverse ear morphology. Some eared moths subsequently developed sound-producing organs to warn/startle/jam attacking bats and/or to communicate intraspecifically with sound. Not only...... the sounds for interaction with bats, but also mating signals are within the frequency range where bats echolocate, indicating that sound communication developed after hearing by “sensory exploitation”. Recent findings on moth sound communication reveal that close-range (~ a few cm) communication with low...

  20. L-type calcium channels refine the neural population code of sound level

    Science.gov (United States)

    Grimsley, Calum Alex; Green, David Brian

    2016-01-01

    The coding of sound level by ensembles of neurons improves the accuracy with which listeners identify how loud a sound is. In the auditory system, the rate at which neurons fire in response to changes in sound level is shaped by local networks. Voltage-gated conductances alter local output by regulating neuronal firing, but their role in modulating responses to sound level is unclear. We tested the effects of L-type calcium channels (CaL: CaV1.1–1.4) on sound-level coding in the central nucleus of the inferior colliculus (ICC) in the auditory midbrain. We characterized the contribution of CaL to the total calcium current in brain slices and then examined its effects on rate-level functions (RLFs) in vivo using single-unit recordings in awake mice. CaL is a high-threshold current and comprises ∼50% of the total calcium current in ICC neurons. In vivo, CaL activates at sound levels that evoke high firing rates. In RLFs that increase monotonically with sound level, CaL boosts spike rates at high sound levels and increases the maximum firing rate achieved. In different populations of RLFs that change nonmonotonically with sound level, CaL either suppresses or enhances firing at sound levels that evoke maximum firing. CaL multiplies the gain of monotonic RLFs with dynamic range and divides the gain of nonmonotonic RLFs with the width of the RLF. These results suggest that a single broad class of calcium channels activates enhancing and suppressing local circuits to regulate the sensitivity of neuronal populations to sound level. PMID:27605536