  1. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  2. Three-dimensional versus two-dimensional sonography of the temporomandibular joint in comparison to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Landes, Constantin A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: c.landes@lycos.com; Goral, Wojciech A. [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: w.goral@gmx.de; Sader, Robert [Oral, Maxillofacial and Plastic Facial Surgery, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: r.sader@em.uni-frankfurt.de; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, Frankfurt University Medical Centre, Theodor-Stern-Kai 7, 60596 Frankfurt (Germany)]. E-mail: martinmack@arcor.de

    2007-02-15

    Aim: To compare clinical feasibility of static two-dimensional (2D) to three-dimensional (3D) sonography of the temporomandibular joint (TMJ) in assessment of disk dislocation and joint degeneration compared to magnetic resonance imaging (MRI). Method: Thirty-three patients, 66 TMJ were prospectively sonographed 2D and 3D (8-12.5 MHz step motor scan), in occlusion and maximum opening with a probe position parallel inferior to the zygomatic arch. Axial 2D images were judged independent from the 3D scans; 3D volumes were cut axial, sagittal, frontal and rotated in real-time. Disk position and joint degeneration were assessed and compared to a subsequent MRI examination. Results: The specific appearance of the disk was hypoechogenic overlying a hyperechogenic condyle in axial (2D) or sagittal and frontal (3D) viewing. Specificity of 2D sonography for disk dislocation was 63%, sensitivity 58%, accuracy 64%, positive predictive value 46%, negative predictive value 73%; for joint degeneration synonymously 59/68/61/38/83%. 3D sonography for disk displacement reached synonymously 68/60/69/51/76%, for joint degeneration 75/65/73/48/86%. 2D sonographic diagnoses of disk dislocation in the closed mouth position and of joint degeneration showed significantly different results from the expected values (MRI) in {chi} {sup 2} testing; 3D diagnoses of disk dislocation in closed mouth position, of joint degeneration, 2D and 3D diagnoses in open mouth position were nonsignificant. Conclusions: Acceptable was the overall negative predictive value, as specificity and accuracy for joint degeneration in 3D. 3D appears superior diagnosing disk dislocation in closed mouth position as for overall joint degeneration. Sensitivity, accuracy and positive predictive value will have to ameliorate with future equipment of higher resolution in real-time 2D and 3D, if sonographic screening shall be clinically applied prior to MRI.

  3. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  4. Accuracy of renal volume assessment in children by three-dimensional sonography; Nierenvolumetrie im Kindesalter: Genauigkeit der dreidimensionalen Sonographie im Vergleich zur konventionellen Sonographie und CT/MRT

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, G.A.; Riccabona, M.; Bohdal, G. [Klinik fuer Radiologie, Universitaetsklinikum Graz (Austria); Quehenberger, F. [Inst. fuer medizinische Informatik, Statistik und Dokumentation, Universitaetsklinikum Graz (Austria)

    2003-04-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 {+-} 4.6% versus a mean difference of -2.4 {+-} 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 {+-} 4.4% for 3DUS and -3.8 {+-} 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 {+-} 5.9% and +9.6 {+-} 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were {+-} 7.3% and {+-} 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [German] Studienziel: Prospektive Evaluation der Genauigkeit des drei-dimensionalen Ultraschalls (3DUS) bei der Volumetrie der kindlichen Niere im Vergleich zur CT/MRT. Methode: Bei 40 Patienten (Alter: 0 - 17 Jahre) mit einer klinisch indizierten CT/MRT des Abdomens oder des Harntrakts wurde zusaetzlich ein 2D- und 3DUS inklusive Volumetrie des

  5. Prenatal diagnosis of Cantrell's pentalogy with conventional and three-dimensional sonography.

    Science.gov (United States)

    León, G; Chedraui, P; San Miguel, G

    2002-09-01

    Omphaloceles and gastroschisis are the most common defects of the fetal anterior abdominal wall. The association of an omphalocele with an anterior thoracic wall defect could result from a variety of congenital syndromes of which Cantrell's pentalogy is the most common. For proper surgical scheduling of the neonate, early diagnosis of each of the components of this syndrome is important. The presence of a congenital intracardiac anomaly is the best predictor of neonatal mortality. We present a case of Cantrell's pentalogy diagnosed prenatally with conventional and three-dimensional sonographic imaging, and confirmed at birth. We discuss this case and the reports in the world literature.

  6. Accuracy of renal volume assessment in children by three-dimensional sonography

    International Nuclear Information System (INIS)

    Fritz, G.A.; Riccabona, M.; Bohdal, G.; Quehenberger, F.

    2003-01-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 ± 4.6% versus a mean difference of -2.4 ± 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 ± 4.4% for 3DUS and -3.8 ± 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 ± 5.9% and +9.6 ± 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were ± 7.3% and ± 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [de

  7. Assessment of the facial features and chin development of fetuses with use of serial three-dimensional sonography and the mandibular size monogram in a Chinese population.

    Science.gov (United States)

    Tsai, Meng-Yin; Lan, Kuo-Chung; Ou, Chia-Yo; Chen, Jen-Huang; Chang, Shiuh-Young; Hsu, Te-Yao

    2004-02-01

    Our purpose was to evaluate whether the application of serial three-dimensional (3D) sonography and the mandibular size monogram can allow observation of dynamic changes in facial features, as well as chin development in utero. The mandibular size monogram has been established through a cross-sectional study involving 183 fetal images. The serial changes of facial features and chin development are assessed in a cohort study involving 40 patients. The monogram reveals that the Biparietal distance (BPD)/Mandibular body length (MBL) ratio is gradually decreased with the advance of gestational age. The cohort study conducted with serial 3D sonography shows the same tendency. Both the images and the results of paired-samples t test (Pmonogram display disproportionate growth of the fetal head and chin that leads to changes in facial features in late gestation. This fact must be considered when we evaluate fetuses at risk for development of micrognathia.

  8. Two- and three-dimensional transvaginal ultrasound with power Doppler angiography and gel infusion sonography for diagnosis of endometrial malignancy.

    Science.gov (United States)

    Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G

    2015-06-01

    To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of

  9. Transabdominal bowl sonography

    DEFF Research Database (Denmark)

    Wilkens, Rune; Strandberg, Charlotte

    2014-01-01

    This focused review describes the current use and future perspectives regarding transabdominal bowel sonography (TABS). The technique for B-mode and Doppler is described and the use of ultrasound contrast and elastography is discussed. Pathology and subsequent imaging findings are focused on appe...... on appendicitis, diverticulitis, inflammatory bowel diseases and within paediatric conditions along with other common intestinal pathology. In conclusion we find that TABS is a fast, efficient, low-cost and non-ionization imaging technique without any patient discomfort....

  10. Evaluation of the therapeutic efficacy of high-intensity focused ultrasound ablation of hepatocellular carcinoma by three-dimensional sonography with a perflubutane-based contrast agent

    International Nuclear Information System (INIS)

    Numata, Kazushi; Fukuda, Hiroyuki; Ohto, Masao; Itou, Ryu; Nozaki, Akito; Kondou, Masaaki; Morimoto, Manabu; Karasawa, Eii; Tanaka, Katsuaki

    2010-01-01

    Objective: We performed contrast-enhanced three-dimensional sonography (CE 3D US) with a perflubutane-based contrast agent to immediately evaluate the completeness of ablation of small hepatocellular carcinoma (HCC) lesions by extracorporeal high-intensity focused ultrasound (HIFU). Subjects and methods: Twenty-one HCC lesions were treated by a single ultrasound-guided HIFU ablation session, and CE 3D US was performed before, immediately after, and 1 week, and 1 month after HIFU, and contrast-enhanced CT (CE CT) or contrast-enhanced MRI (CE MRI) was performed before HIFU, 1 week and 1 month after HIFU, and during the follow-up period. Results: Immediately and 1 month after HIFU, 17 lesions were evaluated as adequately ablated by CE 3D US, and the other 4 lesions as residual tumors. One month after HIFU, 18 were evaluated as adequately ablated by CE CT or CE MRI, and the other 3 as residual tumors. The evaluation by CE 3D US immediately after HIFU and by CE CT or CE MRI 1 month after HIFU was concordant with 20 lesions. The kappa value for agreement between the findings of CE 3D US and other modalities by two blinded observers was 0.83. When the 1-month CE CT or CE MRI findings were used as the reference standard, the sensitivity, specificity, and accuracy of CE 3D US immediately after HIFU for the diagnosis of the adequate ablation were 100%, 75%, and 95%, respectively. Conclusion: CE 3D US appears to be a useful method for immediate evaluation of therapeutic efficacy of HIFU ablation of HCC lesions.

  11. Evaluation of the therapeutic efficacy of high-intensity focused ultrasound ablation of hepatocellular carcinoma by three-dimensional sonography with a perflubutane-based contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Numata, Kazushi, E-mail: kz-numa@urahp.yokohama-cu.ac.j [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Fukuda, Hiroyuki; Ohto, Masao; Itou, Ryu [Department of Internal Medicine, Naruto General Hospital, 167 Naruto, Sanbu, Chiba 289-1326 (Japan); Nozaki, Akito; Kondou, Masaaki; Morimoto, Manabu [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan); Karasawa, Eii [Department of Gastroenterology, International University of Health and Welfare Atami Hospital, 13-1 Higashi Kaigan-cho, Atami, Shizuoka 413-0012 (Japan); Tanaka, Katsuaki [Gastroenterological Center, Yokohama City University Medical Center, 4-57 Urafune-cho, Minami-ku, Yokohama, Kanagawa 232-0024 (Japan)

    2010-08-15

    Objective: We performed contrast-enhanced three-dimensional sonography (CE 3D US) with a perflubutane-based contrast agent to immediately evaluate the completeness of ablation of small hepatocellular carcinoma (HCC) lesions by extracorporeal high-intensity focused ultrasound (HIFU). Subjects and methods: Twenty-one HCC lesions were treated by a single ultrasound-guided HIFU ablation session, and CE 3D US was performed before, immediately after, and 1 week, and 1 month after HIFU, and contrast-enhanced CT (CE CT) or contrast-enhanced MRI (CE MRI) was performed before HIFU, 1 week and 1 month after HIFU, and during the follow-up period. Results: Immediately and 1 month after HIFU, 17 lesions were evaluated as adequately ablated by CE 3D US, and the other 4 lesions as residual tumors. One month after HIFU, 18 were evaluated as adequately ablated by CE CT or CE MRI, and the other 3 as residual tumors. The evaluation by CE 3D US immediately after HIFU and by CE CT or CE MRI 1 month after HIFU was concordant with 20 lesions. The kappa value for agreement between the findings of CE 3D US and other modalities by two blinded observers was 0.83. When the 1-month CE CT or CE MRI findings were used as the reference standard, the sensitivity, specificity, and accuracy of CE 3D US immediately after HIFU for the diagnosis of the adequate ablation were 100%, 75%, and 95%, respectively. Conclusion: CE 3D US appears to be a useful method for immediate evaluation of therapeutic efficacy of HIFU ablation of HCC lesions.

  12. Chest sonography. 2. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Mathis, Gebhard (ed.)

    2008-07-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  13. Chest sonography. 2. ed.

    International Nuclear Information System (INIS)

    Mathis, Gebhard

    2008-01-01

    Chest sonography is an established procedure in the stepwise imaging diagnosis of pulmonary and pleural disease. It is the method of choice to distinguish between solid and liquid lesions and allows the investigator to make an unequivocal diagnosis without exposing the patient to costly and stressful procedures. This book presents the state of the art in chest investigation by means of ultrasonography. A number of excellent illustrations and the compact text provide concise and easy-to-assimilate information about the diagnostic procedure. Basic elements such as indications, investigation techniques and image artifacts are detailed in separate chapters. (orig.)

  14. Sonography of acne vulgaris.

    Science.gov (United States)

    Wortsman, Ximena; Claveria, Pedro; Valenzuela, Fernando; Molina, Maria Teresa; Wortsman, Jacobo

    2014-01-01

    The purpose of this study was to assess the sonographic morphology of the clinical and subclinical pathology of facial acne vulgaris. We studied patients with facial acne vulgaris diagnosed by certified dermatologists, and using a standardized protocol for sonographic examinations, we sequentially described the sonographic pathomorphologic characteristics. Lesions of particular interest to the referring clinician were also analyzed separately. Additionally, acne involvement was staged clinically and sonographically (SOS-Acne) using morphologic definitions of the relevant lesions and predefined scoring systems for gradation of the severity of acne lesions. A total of 245 acne lesions in 20 consecutive patients were studied. Sonographic abnormalities consisted of pseudocysts, folliculitis, fistulas, and calcinosis. Most conditions were subclinical and mostly due to lesion extensions deep into the dermis and hypodermis (52% of pseudocysts and 68% of fistulas). The statistical concordance between acne severity scores assigned by two separate clinicians was strong (κ = 0.8020), but the corresponding sonographic scores generally showed more severe and clinically occult involvement. Facial acne vulgaris often involves deeper tissues, beyond the reach of the spatially restricted clinical examination; these subclinical conditions can be detected and defined with sonography. Additionally, acne vulgaris is amenable to sonographic scoring.

  15. Principles and practice of sonography

    International Nuclear Information System (INIS)

    Fleischer, A.C.; James, A.E.

    1987-01-01

    This book is a text of sonographic technique, emphasizing clinical and diagnostic procedures. Ultrasound images and explanatory line drawings are placed side-by-side to facilitate interpretation. This book covers instrumentation and scanning principles, obstetric, gynecologic, abdominal, renal and urologic, pediatric, plus superficial structure sonography

  16. Perforated pyloroduodenal peptic ulcer and sonography.

    Science.gov (United States)

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  17. Duplex sonography in portal hypertension

    International Nuclear Information System (INIS)

    Kwon, Hyuk Po; Jang, J. C.; Park, B. H.

    1990-01-01

    We measure the diameter and blood velocity of the portal vein in 50 patients with cirrhosis of the liver and 40 healthy subjects, and calculated cross sectional area, mean blood flow velocity, blood flow volume and congestion index. In patients with cirrhosis of the liver, the cross sectional area of the portal vein was significantly increased: the mean blood flow volume was significantly reduced; the blood flow volume was significantly increased; the congestion index of the portal vein was significantly increased. Duples sonography may play an important role in the diagnosis of portal hypertension

  18. Ideal Positions: 3D Sonography, Medical Visuality, Popular Culture.

    Science.gov (United States)

    Seiber, Tim

    2016-03-01

    As digital technologies are integrated into medical environments, they continue to transform the experience of contemporary health care. Importantly, medicine is increasingly visual. In the history of sonography, visibility has played an important role in accessing fetal bodies for diagnostic and entertainment purposes. With the advent of three-dimensional (3D) rendering, sonography presents the fetus visually as already a child. The aesthetics of this process and the resulting imagery, made possible in digital networks, discloses important changes in the relationship between technology and biology, reproductive health and political debates, and biotechnology and culture.

  19. One-step transvaginal three-dimensional hysterosalpingo-foam sonography (3D-HyFoSy) confirmation test for Essure® follow-up: a multicenter study.

    Science.gov (United States)

    Zizolfi, B; Lazzeri, L; Franchini, M; Di Spiezio Sardo, A; Nappi, C; Piccione, E; Exacoustos, C

    2018-01-01

    To evaluate, in patients who underwent Fallopian-tube sterilization by hysteroscopic insertion of an Essure® device, the feasibility and accuracy of three-dimensional (3D) transvaginal sonography (TVS) to check the position of the device and 3D hysterosalpingo-foam sonography (3D-HyFoSy) using contrast-enhanced gel foam to assess consequent tubal occlusion. This was a prospective multicenter study conducted from June 2012 to July 2014 in four Italian centers, which included 50 women who underwent hysteroscopic Essure microinsert placement in a total of 95 Fallopian tubes. Placement of the microinserts was performed in an outpatient setting following standard procedure recommendations. All patients underwent transvaginal 3D-HyFoSy and hysterosalpingography (HSG) approximately 12-14 weeks after the procedure. The position of the devices was first checked on 3D-TVS and classified according to specific criteria (Positions A, B, C and D). Then, 3D-HyFoSy with ExEm® gel foam as the ultrasound contrast agent was performed to confirm tubal occlusion by the absence of contrast agent within the tubes and/or around the ovaries. To evaluate the feasibility of 3D-HyFoSy, consecutive volume acquisitions were performed while injecting the gel foam. After sonographic evaluation, women underwent HSG to assess the success of sterilization, as standard methodology. Side effects and pain evoked during and after 3D-HyFoSy and HSG were evaluated using a numeric pain rating scale. On 3D-TVS, 10 devices (10.5%) were in Position A, two (2.1%) in Position B, 59 (62.1%) in Position C and 24 (25.3%) in Position D. During 3D-HyFoSy, tubal occlusion was observed in 89 of 95 tubes (93.7%). In the six cases in which the passage of the contrast was observed, one device (16.7%) was in Position B, one device (16.7%) in Position D and four devices (66.7%) were found to lie in Position C. Tubal patency was confirmed at HSG with a concordance rate of 100%. The mean pain score associated with 3D

  20. Sonography of cat scratch disease.

    Science.gov (United States)

    Melville, David M; Jacobson, Jon A; Downie, Brian; Biermann, J Sybil; Kim, Sung Moon; Yablon, Corrie M

    2015-03-01

    To characterize the sonographic features of cat scratch disease and to identify features that allow differentiation from other causes of medial epitrochlear masses. After Institutional Review Board approval was obtained, patients who underwent sonography for a medial epitrochlear mass or lymph node were identified via the radiology information system. Patients were divided into 2 groups: cat scratch disease and non-cat scratch disease, based on pathologic results and clinical information. Sonograms were retrospectively reviewed and characterized with respect to dimension, shape (round, oval, or lobular), symmetry, location (subcutaneous or intramuscular), multiplicity, echogenicity (anechoic, hypoechoic, isoechoic, hyperechoic, or mixed), hyperechoic hilum (present or absent), adjacent anechoic or hypoechoic area, hyperemia (present or absent), pattern of hyperemia if present (central, peripheral, or mixed), increased posterior through-transmission (present or absent), and shadowing (present or absent). Sonographic findings were compared between the patients with and without cat scratch disease. The final patient group consisted of 5 cases of cat scratch disease and 16 cases of other causes of medial epitrochlear masses. The 2 sonographic findings that were significantly different between the cat scratch disease and non-cat scratch disease cases included mass asymmetry (P = .0062) and the presence of a hyperechoic hilum (P = .0075). The other sonographic findings showed no significant differences between the groups. The sonographic finding of an epitrochlear mass due to cat scratch disease most commonly is that of a hypoechoic lobular or oval mass with central hyperemia and a possible adjacent fluid collection; however, the presence of asymmetry and a hyperechoic hilum differentiate cat scratch disease from other etiologies. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Sonography in the diagnosis of acute appendicitis

    Directory of Open Access Journals (Sweden)

    Ahmad Ryazi

    2003-09-01

    Full Text Available Graded compressive sonography may be useful as an adjuvant in the diagnosis of acute appendicitis. To determine the role of sonography in the differential diagnosis of acute appendicitis, preappendectomy sonographic data of 164 consecutive cases in Fatemeh-Zahra Teaching Hospital were evaluated. Of 113 (68.9% patients who had acute appendicitis in histopathology, 64 (56.6% cases had preoperative sonographic diagnosis of acute appendicitis. Of 51 patients who had normal appendices, 40 (78.4% cases had normal appendices in sonographic evaluations. Sensitivity, specificity and accuracy of sonography for acute appendicitis were 56.7%, 78.4% and 0.63, respectively. The positive and negative predictive values were 85.3% and 44.49% respectively. As a result, sonographic evaluation is an additional diagnostic tool in acute appendicitis.

  2. Brain sonography in African infants with complicated sporadic ...

    African Journals Online (AJOL)

    Background: To determine the structural findings in brain sonography of African infants with complicated sporadic bacterial meningitis. Materials and Methods: Retrospective assessment of medical records of patients who underwent brain sonography on account of complicated bacterial meningitis. The brain sonography ...

  3. Transvaginal sonography of acute pelvic inflammatory disease

    International Nuclear Information System (INIS)

    Choi, Jin Soo; Kim, Young Hwa; Shin, Hyung Chul; Han, Gun Soo; Kim, Il Young

    1999-01-01

    To determine the value of transvaginal sonography in evaluating women with acute pelvic inflammatory disease (PID). Transvaginal sonography was performed in 25 patients with clinically suggested PID during recent 36 months. The sonographic findings of fallopian tubes and ovaries were analyzed and correlated with pathological findings of 2 fallopian tubes and 19 ovaries in 16 patients who had operations. The correct diagnosis of acute PID was made in 20/25 (80%) by transvaginal sonography. the abnormal sonographic findings of the fallopian tube include tubal thickening or dilatation with internal echo. The sensitivity, specificity, and accuracy for tubal abnormality were 88%, 96%, and 86% , respectively. Ovarian changes were seen on TVS in 14/19 (73%), which include multiple follicular enlargement in 5, tubo-ovarian complex in 9 (tubo-ovarian adhesion in 3, tubo-ovarian abscess in 6). At surgery, the ovay was not involved in all three women who showed tubo-ovarian adhesion on TVS. Among 6 women who showed tubo-ovarian abscess on TVS, tubo-ovarian abscess was confirmed in 3 and the remaining 3 had ovarian cysts. Trandvaginal sonography, a facilitative and accurate modality, is highly sensitive in detecting the abnormality of the tube and useful in differentiating the tubo-ovarian complex in patients with acute PID.

  4. Gastrointestinal tract sonography in fetuses and children

    Energy Technology Data Exchange (ETDEWEB)

    Couture, Alain; Baud, Catherine; Ferran, Jean Louis; Saguintaah, Magali; Veyrac, Corinne [Hopital Arnaud de Villeneuve, 34 - Montpellier (France). Service de Radiologie Pediatrique

    2008-07-01

    Sonography of the gastrointestinal tract in fetuses, neonates and children entails no known biological risk, permits serial scanning and can provide information unobtainable with any other imaging modality. In experienced hands it can be used as the initial imaging technique in a number of gastrointestinal diseases and conditions. This book provides a comprehensive account of the current state of the art regarding sonography in this context. An introductory chapter compares the merits of sonography and magnetic resonance imaging of the fetal gastrointestinal tract. Subsequent chapters focus on the technique, pitfalls and findings in a wide variety of applications, including antropyloric diseases, bowel obstruction, bowel wall thickening, colitis, appendicitis, some types of intussusception, abdominal wall and umbilical abnormalities, intraperitoneal tumors, and trauma. In each case the sonographic morphology is considered in depth with the aid of high-quality illustrations. A concluding chapter comprises a quiz based on 15 case reports. Gastrointestinal Tract Sonography in Fetuses and Children will be of value to all with an interest in this field. (orig.)

  5. Mammography and breast sonography in transsexual women

    Energy Technology Data Exchange (ETDEWEB)

    Weyers, S., E-mail: steven.weyers@ugent.b [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Villeirs, G.; Vanherreweghe, E. [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Verstraelen, H. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Monstrey, S. [Department of Plastic Surgery, Ghent University Hospital, Ghent (Belgium); Van den Broecke, R.; Gerris, J. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium)

    2010-06-15

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  6. Mammography and breast sonography in transsexual women

    International Nuclear Information System (INIS)

    Weyers, S.; Villeirs, G.; Vanherreweghe, E.; Verstraelen, H.; Monstrey, S.; Van den Broecke, R.; Gerris, J.

    2010-01-01

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  7. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  8. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  9. Intelligent navigation to improve obstetrical sonography.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2016-04-01

    'Manual navigation' by the operator is the standard method used to obtain information from two-dimensional and volumetric sonography. Two-dimensional sonography is highly operator dependent and requires extensive training and expertise to assess fetal anatomy properly. Most of the sonographic examination time is devoted to acquisition of images, while 'retrieval' and display of diagnostic planes occurs rapidly (essentially instantaneously). In contrast, volumetric sonography has a rapid acquisition phase, but the retrieval and display of relevant diagnostic planes is often time-consuming, tedious and challenging. We propose the term 'intelligent navigation' to refer to a new method of interrogation of a volume dataset whereby identification and selection of key anatomical landmarks allow the system to: 1) generate a geometrical reconstruction of the organ of interest; and 2) automatically navigate, find, extract and display specific diagnostic planes. This is accomplished using operator-independent algorithms that are both predictable and adaptive. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) is a tool that allows operator-independent sonographic navigation and exploration of the surrounding structures in previously identified diagnostic planes. The advantage of intelligent (over manual) navigation in volumetric sonography is the short time required for both acquisition and retrieval and display of diagnostic planes. Intelligent navigation technology automatically realigns the volume, and reorients and standardizes the anatomical position, so that the fetus and the diagnostic planes are consistently displayed in the same manner each time, regardless of the fetal position or the initial orientation. Automatic labeling of anatomical structures, subject orientation and each of the diagnostic planes is also possible. Intelligent navigation technology can operate on conventional computers, and is not dependent on specific ultrasound platforms or on the

  10. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  11. The cardiac sonography workforce in New Zealand

    Science.gov (United States)

    White, Steve; Poppe, Katrina; Whalley, Gillian

    2015-01-01

    Abstract Introduction: The aim of this paper is to investigate the cardiac sonography workforce characteristics and registration requirements in New Zealand (NZ), with a comparison to similar workforces internationally. Methods: The Survey of Clinical Echocardiography in New Zealand 2 (SCANZ2) audit was performed in December 2010. All of NZ's public‐funded District Health Board (DHB) centers providing echocardiography services responded to questions relating to staff, equipment, procedure types and patient statistics. The Medical Radiation Technologists Board (MRTB), Clinical Physiologists Registration Board (CPRB) and Australian Sonographers Association Registry (ASAR) websites were reviewed in March 2012 for registered sonographers with a cardiac scope of practice. The cardiac sonography workforces in Australia, the UK, the USA and Canada were investigated for comparison. Results: There are 84 cardiac sonographers (60.3 full‐time equivalent) working in DHBs: 71% from a cardiac technical background; 40% have post‐graduate qualifications; a further 17% are undertaking post‐graduate qualifications; and 59 cardiac sonographers have registration with professional bodies in NZ and/or Australia. Cardiac sonographers in NZ do not undergo compulsory registration, but other sonographers in NZ have compulsory registration with the MRTB. Sonographers are predominantly not licensed internationally. Discussion: Disparity exists between registration of cardiac and non‐cardiac sonographers in NZ. Many cardiac sonographers have voluntary registration but few are registered with the MRTB. Reasons for this include professional alignment, educational qualifications and representation. International trends show increased pressure from governments and professional bodies to regulate sonographers. Conclusion: This study provides a snapshot of the cardiac sonography workforce in NZ for the first time. PMID:28191178

  12. Role of sonography in the diagnosis of Echinococcus alveolaris

    Energy Technology Data Exchange (ETDEWEB)

    Maier, W.

    1983-02-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation.

  13. The role of sonography in the diagnosis of Echinococcus alveolaris

    International Nuclear Information System (INIS)

    Maier, W.

    1983-01-01

    Abdominal sonography and computed tomography were performed in eleven patients with operatively and histologically proven Echinococcus alveolaris of the liver and the detailed appearances were compared. Sonography is a useful screening method in the assessment of E. alveolaris, but its previous importance is being gradually superseded by computed tomography, which is capable of providing more detailed information in the diagnosis of Echinococcus infestation. (orig.)

  14. 21 CFR 872.2050 - Dental sonography device.

    Science.gov (United States)

    2010-04-01

    ... § 872.9. (b) Dental sonography device for interpretation and diagnosis—(1) Identification. A dental sonography device for interpretation and diagnosis is an electrically powered device, intended to interpret temporomandibular joint sounds for the diagnosis of temporomandibular joint disorders and associated orofacial pain...

  15. Transvaginal versus transabdominal sonography in the evaluation of pelvic pathology

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Ullah, H.; Akram, M.H.; Ashfaq, S.; Nayyar, S.

    2004-01-01

    Objective: To find the accuracy of sonographic information provided by transvaginal sonography (TVS) in pelvic pathology as compared to transabdominal sonography (TAS). Materials and Methods: Hundred patients were included in the study from a total of 212 referred for pelvic sonography. Two radiologists independently performed transabdominal and transvaginal sonography of these patients. An independent observer compared the findings. TVS was graded as superior, equal or inferior to TAS depending on the score assigned by them. Results: TVS was considered superior in 63%, equal in 27% and inferior in 10% of the cases as compared to transabdominal sonography. It was graded inferior to TAS in cases with large pelvic masses and superior in majority of cases of ovarian follicle monitoring, polycystic ovaries, endometrial carcinoma and suspected ectopic pregnancy. Cases in which both techniques were considered equal included patients with no abnormal finding, some pelvic masses and advanced pelvic inflammatory disease. Conclusion: Transvagival sonography is superior to transabdominal sonography in most cases of pelvic pathology. However, TAS should still be the initial sonographic technique for routine evaluation of the female pelvis followed by TVS if indicated. In cases of ovarian follicle monitoring, suspected polycystic ovaries, endometrial pathology and suspected ectopic pregnancy, TVS may be used as the initial sonographic technique and can even replace TAS. (author)

  16. Duplex sonography of the near-surface leg veins

    International Nuclear Information System (INIS)

    Mendoza, E.

    2007-01-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins

  17. Real-time sonography in obstetrics.

    Science.gov (United States)

    Anderson, S G

    1978-03-01

    Three hundred fifty real-time scans were performed on pregnant women for various indications. Placental localization was satisfactorily obtained in 173 of 174 studies. Estimates of fetal gestation from directly measured biparietal diameter were +/-2 weeks of actual gestation in 153 of 172 (88.9%) measurements. The presence or absence of fetal motion and cardiac activity established a diagnosis of fetal viability or fetal death in 32 patients after the first trimester. Accurate diagnosis was made in 52 of 57 patients with threatened abortions, and two of these errors occurred in scans performed before completion of the eighth postmenstrual week. Because of the ability to demonstrate fetal motion, real-time sonography should have many applications in obstetrics.

  18. Rotator cuff ruptures of the shoulder joint, sonography - arthrography

    International Nuclear Information System (INIS)

    Triebel, H.J.; Wening, V.; Witte, G.; Hamburg Univ.

    1986-01-01

    47 patients suspected of rutpure of the rotator cuff were sonographed and arthrographed. Rupture of the rotator cuff was diagnosed in 12 cases, both diagnostic methods yielding the same result. In 29 patients sonography and arthrography did not reveal any abnormal findings. Six ruptures evident in sonography were not confirmed by arthrography and were considered false positive. Direct pointers towards rupture of the cuff would be: echoless defects, cuff cannot be visualised fully or in part and irregularities of movement during dynamic examination. Echoless 'cystic' areas in the periarticular soft parts must be considered an indirect pointer. Echorich focal findings in the echopoor cuff represent a differential diagnostic problem and we cannot give a final assessment as yet. Shoulder sonography is justified as a screening method in suspicion of rotator cuff rupture before initiating arthrography. If sonography reveals no abnormal findings, shoulder arthrography need not be performed. (orig.) [de

  19. Transcranial Duplex Sonography Predicts Outcome following an Intracerebral Hemorrhage.

    Science.gov (United States)

    Camps-Renom, P; Méndez, J; Granell, E; Casoni, F; Prats-Sánchez, L; Martínez-Domeño, A; Guisado-Alonso, D; Martí-Fàbregas, J; Delgado-Mederos, R

    2017-08-01

    Several radiologic features such as hematoma volume are related to poor outcome following an intracerebral hemorrhage and can be measured with transcranial duplex sonography. We sought to determine the prognostic value of transcranial duplex sonography in patients with intracerebral hemorrhage. We conducted a prospective study of patients diagnosed with spontaneous intracerebral hemorrhage. Transcranial duplex sonography examinations were performed within 2 hours of baseline CT, and we recorded the following variables: hematoma volume, midline shift, third ventricle and lateral ventricle diameters, and the pulsatility index in both MCAs. We correlated these data with the CT scans and assessed the prognostic value of the transcranial duplex sonography measurements. We assessed early neurologic deterioration during hospitalization and mortality at 1-month follow-up. We included 35 patients with a mean age of 72.2 ± 12.8 years. Median baseline hematoma volume was 9.85 mL (interquartile range, 2.74-68.29 mL). We found good agreement and excellent correlation between transcranial duplex sonography and CT when measuring hematoma volume ( r = 0.791; P duplex sonography measurements showed that hematoma volume was an independent predictor of early neurologic deterioration (OR, 1.078; 95% CI, 1.023-1.135) and mortality (OR, 1.089; 95% CI, 1.020-1.160). A second regression analysis with CT variables also demonstrated that hematoma volume was associated with early neurologic deterioration and mortality. When we compared the rating operation curves of both models, their predictive power was similar. Transcranial duplex sonography showed an excellent correlation with CT in assessing hematoma volume and midline shift in patients with intracerebral hemorrhage. Hematoma volume measured with transcranial duplex sonography was an independent predictor of poor outcome. © 2017 by American Journal of Neuroradiology.

  20. The accuracy of transvaginal sonography to detect endometriosis cyst

    Science.gov (United States)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  1. Transcranial Doppler sonography as diagnostic method

    Directory of Open Access Journals (Sweden)

    Jasminka Đelilović-Vranić

    2002-02-01

    Full Text Available Having in mind the fact that cerebrovascular disease (CVB takes today in medicine, in spite of diagnostic and therapeutic modernisation, the third place of mortality causes in the world (behind cordial and malignant diseases, but in front of depressions, and the second place of invalidity cause (right after trauma as well as the second place of dementia cause (after Alzheimer disease, it urges primary prophylaxis. Developing countries, but before all countries of East and Middle Europe, where is our country, are highly risked areas where CV disease has trend of incidence and total frequency increase. In the neighbouring Croatia today CV disease is at the first place of mortality causes. In the world today 5 million people annually suffer CV disease, in Europe about 700.000, but frequency of suffering on Balkan is about 5 prom. Age of CV disease effecting unfortunately moved towards young age, and today 49% of effected by CV disease are of 46 to 59 years of age. Early detection and treatment of risk factors (before hypertension, smoking, diabetes mellitus, hyperlipidaemia, stress and physical non-activities are the first aspect of CV disease prophylaxis. Together with this aspect of primary prophylaxis is early detection of complications of mentioned risk factors on the walls of blood vessels, before all changing in sense of arteriosclerosis, with consequence of disorder of cerebral haemodynamics. With that objective - verification of circulator and total haemodynamic disorders, there is obvious disclose of non-invasive diagnostic methods, and one of them is Transcranial Doppler Sonography(TCD. TCD is method comfortable for patient, reliable and rather precise, dynamic, and can be repeated several times, without side effects and in comparison with others rather cheap.

  2. Transcranial sonography for diagnosis of Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Maaser Peter

    2010-01-01

    Full Text Available Abstract Background In idiopathic Parkinson's disease (IPD transcranial sonography (TCS represents an alternative diagnostic method to verify clinical diagnosis. Although the phenomenon of an increased echogenicity of the Substantia nigra (SN is well known this method is still not widly used in the diagnostic workup. Until now reliability of this method is still a matter of debate, partly because data only existed from a few laboratories using the same ultrasound machine. Therefore our study was conducted to test the reliability of this method by using a different ultrasound device and examining a large population of control and IPD subjects by two examiners to calculate interobserver reliability. Method In this study echogenicity of SN was examined in 199 IPD patients and 201 control subjects. All individuals underwent a neurological assessment including Perdue pegboard test and Webster gait test. Using a Sonos 5500 ultrasound device area of SN was measured, echogenicity of raphe, red nuclei, thalamus, caudate and lenticular nuclei, width of third and lateral ventricle were documented. Results We found a highly characteristic enlargement of the SN echogenic signal in IPD. The cut-off value for the SN area was established using a ROC curve with a sensitivity of 95% corresponding to an area of SN of 0.2 cm2 and was found to be equivalent to the cut-off values of other studies using different ultrasound devices. Conclusions Our study shows that TCS is a reliable and highly sensitive tool for differentiation of IPD patients from individuals without CNS disorders.

  3. Not all ultrasounds are created equal: general sonography versus musculoskeletal sonography in the detection of rotator cuff tears

    Science.gov (United States)

    Cole, Brandi; Twibill, Kristen; Lam, Patrick; Hackett, Lisa

    2016-01-01

    Background This cross-sectional analytic diagnostic accuracy study was designed to compare the accuracy of ultrasound performed by general sonographers in local radiology practices with ultrasound performed by an experienced musculoskeletal sonographer for the detection of rotator cuff tears. Methods In total, 238 patients undergoing arthroscopy who had previously had an ultrasound performed by both a general sonographer and a specialist musculoskeletal sonographer made up the study cohort. Accuracy of diagnosis was compared with the findings at arthroscopy. Results When analyzed as all tears versus no tears, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 95%, whereas general sonography had an accuracy of 91%, a sensitivity of 91% and a specificity of 86%. When the partial tears were split with those ≥ 50% thickness in the tear group and those tear group, musculoskeletal sonography had an accuracy of 97%, a sensitivity of 97% and a specificity of 100% and general sonography had an accuracy of 85%, a sensitivity of 84% and a specificity of 87%. Conclusions Ultrasound in the hands of an experienced musculoskeletal sonographer is highly accurate for the diagnosis of rotator cuff tears. General sonography has improved subsequent to earlier studies but remains inferior to an ultrasound performed by a musculoskeletal sonographer. PMID:27660657

  4. Clinical applications of imaging reconstruction by virtual sonography

    International Nuclear Information System (INIS)

    Mori, Akihiro; Oohashi, Noritsugu; Maruyama, Takako; Tatebe, Hideharu; Fushimi, Nobutoshi; Asano, Takayuki; Inoue, Hiroshi; Okuno, Masataka

    2008-01-01

    One of the pitfalls in managing multiple liver tumors is the difficulty in identifying individual tumors on ultrasonography. Computed tomography (CT)-assisted virtual sonography has been shown to improve sonographic diagnosis, however it requires additional equipment and software. We have developed a simple reconstruction method of virtual sonography (SRVS). We reconstructed SRVS mimicking ultrasonographic images, utilizing a workstation software attached to a multi-detector row CT system without any additional program. We have performed SRVS in 32 patients with 41 liver tumors that could hardly be identify on ultrasonography. SRVS assisted the identification of malignant form non-pathologic ones and thereby contributed to the appropriate clinical strategy including radiofrequency ablation (RFA) (18 tumors), liver biopsy (2 tumors), other therapies (4 tumors) and follow-up (17 tumors). We have developed virtual sonography using conventional CT software. SRVS seems useful in the clinical practice in managing liver tumors. (author)

  5. New developments in imaging: Sonography, cine-CT, MRI

    International Nuclear Information System (INIS)

    Otto, R.J.; Higgins, C.B.

    1987-01-01

    The book can be conveniently subdivided into three sections: the first on magnetic resonance imaging the second on cine-computed tomography and the third on advances in ultrasound (US). The MR imaging section includes two chapters: the first on indications for MR in abdominal disease (a cookbook layout of indications for MR imaging versus CT) and the second on MR imaging of the heart. There are also chapters on MR imaging and US in the pelvis, contrast agent principles, and a chapter on imaging renal tumors. The third section, on US, contains chapters on the liver and gastrointenstinal disease, interventional US sonography during neurosurgery, state-of-the-art echocardiography. Doppler flow imaging, contrast media for sonography, endometrial sonography, and high-resolution US in the first trimester. The final chapter is presented as a scientific paper rather than as a chapter in a book and has no illustrations

  6. Sonography in the postoperative evaluation of laparoscopic inguinal hernia repair.

    Science.gov (United States)

    Furtschegger, A; Sandbichler, P; Judmaier, W; Gstir, H; Steiner, E; Egender, G

    1995-09-01

    We evaluated the use of sonography as a means of assessing hernial occlusion and possible postoperative changes such as hematomas or seromas in the inguinal and scrotal regions after 1139 laparoscopic repairs of hernias between August 1992 and November 1994. Changes after laparoscopic hernia repair were found in 307 patients (27%). Hematomas or seromas were seen in 132 patients, protrusion of the prosthetic mesh in 17, mesh infection in two, and small bowel entrapment in an insufficient peritoneal suture in two. Recurrences were diagnosed correctly in six patients, mobile preperitoneal lipomas in five. Sonography is useful in the evaluation of complications after laparoscopic hernia repair, including recurrent hernia. In the absence of symptoms, sonography is not indicated.

  7. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  8. Addison's disease with adrenal enlargement on sonography and computed toimography

    International Nuclear Information System (INIS)

    Renner, F.; Graninger, W.

    1986-01-01

    One of the major causes of chronic adrenal insufficiency (Addison's disease) is tuberculous adrenalopathy. Since sonography and computed tomography have become generally available in recent years and are of potential help in the diagnosis of this disease the merits of these methods are discussed in the light of 2 cases of adrenal tuberculosis, followed by a review of the literature. Adrenal calcification is the most significant, although not specific sign of adrenal insufficiency due to tuberculosis. Computed tomography has proven to be the method of choice in the non-invasive diagnosis of tuberculous adrenalopathy and in the monitoring of tuberculostatic treatment in this disease. Sonography is helpful as a preliminary investigation. (Author)

  9. The demonstration of gall stones by sonography and radiography

    International Nuclear Information System (INIS)

    Gladisch, R.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1983-01-01

    Eighty-seven unselected gall stones were examined radiologically and by ultrasound in vitro. No relationship of diagnostic value could be established between the amount of calcification and stone demonstration, the sonogram being influenced by the size of the stone, its surface contour and its position in the ultrasound beam. Sonography is therefore not suitable for selecting those patients on whom litholysis could be carried out. Sonography appears to be useful only in a negative way by establishing the exact size of the concretion. (orig.) [de

  10. Management of threatened abortion with real-time sonography.

    Science.gov (United States)

    Anderson, S G

    1980-02-01

    Real-time sonography was used to evaluate 158 patients with threatened abortion. Fetal motion was first detected during the seventh gestational week and with increasing frequency thereafter in 73 patients with viable pregnancies continuing to term. Only 2 of 65 patients who aborted demonstrated fetal motion. The presence or absence of fetal motion was most reliable after 7 weeks' gestation for establishing a prognosis for a given pregnancy. Seventy-two of 74 pregnancies with fetal motion continued to term, whereas 63 of 64 pregnancies without fetal motion aborted. A method for using real-time sonography in the management of threatened abortion is presented.

  11. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  12. Language Lateralization in Children Using Functional Transcranial Doppler Sonography

    Science.gov (United States)

    Haag, Anja; Moeller, Nicola; Knake, Susanne; Hermsen, Anke; Oertel, Wolfgang H.; Rosenow, Felix; Hamer, Hajo M.

    2010-01-01

    Aim: Language lateralization with functional transcranial Doppler sonography (fTCD) and lexical word generation has been shown to have high concordance with the Wada test and functional magnetic resonance imaging in adults. We evaluated a nonlexical paradigm to determine language dominance in children. Method: In 23 right-handed children (12…

  13. Upper Abdominal Ultra-Sonography Findings in HIV Patients at ...

    African Journals Online (AJOL)

    Design: A descriptive cross-sectional study. Setting: Kenyatta National Hospital and the Defence Forces Memorial Hospital, Nairobi, Kenya. Subjects: HIV infected patients referred for upper abdominal sonography within the study duration of eight months. Results: Two hundred and seventy three (273) patients were ...

  14. Pseudoaneurysm of the posterior circumflex humeral artery diagnosed by sonography

    DEFF Research Database (Denmark)

    Damgaard, Bodil; Court-Payen, Michel; Larsen, Lone

    2009-01-01

    with a painless, nonpulsatile mass in the posterior shoulder region and was suspected of a malignant soft-tissue tumor. Sonography, including power Doppler imaging, demonstrated a pseudoaneurysm, with the intralesional blood-filled cavity developed from the posterior circumflex humeral artery. The diagnosis...

  15. Role of focused assessment with sonography for trauma as a ...

    African Journals Online (AJOL)

    Background: The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical ...

  16. Afferent loop syndrome: Role of sonography and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1992-03-15

    Afferent loop syndrome(ALS) is caused by obstruction of the afferent loop after subtotal gastrectomy with Billroth II gastrojejunostomy. Prompt diagnosis of ALS is important as perforation of the loop occurs. The aim of study is to ascertain the sonography and CT to diagnose ALS. We describe the radiologic findings in ten patients with ALS. The cause of ALS, established at surgery, included cancer recurrence (n=4), internal hernia (n=4), marginal ulcer (n=1), and development of cancer at the anastomosis site (n=1). Abdominal X-ray and sonography were performed in all cases, upper GI series in five cases and computed tomography in two cases. The dilated afferent loop was detected in only two cases out often patients in retrospective review of abdominal X-ray. ALS with recurrence of cancer was diagnosed in three cases by upper GI series. Of the cases that had sonography, the afferent loop was seen in the upper abdomen crossing transversely over the midline in all ten patients. The cause of ALS were predicated on the basis of the sonograms in three of the five patients. In two cases of computed tomography, the dilated afferent loop and recurrent cancer at the remnant stomach were seen.Our experience suggests that the diagnosis of afferent syndrome can be made on the basis of the typical anatomic location and shape of the dilated bowel loop in both sonography and computed tomography.

  17. Diagnostic accuracy of sonography for pleural effusion: systematic review

    Directory of Open Access Journals (Sweden)

    Alexandre Grimberg

    Full Text Available CONTEXT AND OBJECTIVE: The initial method for evaluating the presence of pleural effusion was chest radiography. Isolated studies have shown that sonography has greater accuracy than radiography for this diagnosis; however, no systematic reviews on this matter are available in the literature. Thus, the aim of this study was to evaluate the accuracy of sonography in detecting pleural effusion, by means of a systematic review of the literature. DESIGN AND SETTING: This was a systematic review with meta-analysis on accuracy studies. This study was conducted in the Department of Diagnostic Imaging and in the Brazilian Cochrane Center, Discipline of Emergency Medicine and Evidence-Based Medicine, Department of Medicine, Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHOD: The following databases were searched: Cochrane Library, Medline, Web of Science, Embase and Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs. The references of relevant studies were also screened for additional citations of interest. Studies in which the accuracy of sonography for detecting pleural effusion was tested, with an acceptable reference standard (computed tomography or thoracic drainage, were included. RESULTS: Four studies were included. All of them showed that sonography had high sensitivity, specificity and accuracy for detecting pleural effusions. The mean sensitivity was 93% (95% confidence interval, CI: 89% to 96%, and specificity was 96% (95% CI: 95% to 98%. CONCLUSIONS: In different populations and clinical settings, sonography showed consistently high sensitivity, specificity and accuracy for detecting fluid in the pleural space.

  18. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.

    Science.gov (United States)

    Swiat, Maciej; Weigele, John; Hurst, Robert W; Kasner, Scott E; Pawlak, Mikolaj; Arkuszewski, Michal; Al-Okaili, Riyadh N; Swiercz, Miroslaw; Ustymowicz, Andrzej; Opala, Grzegorz; Melhem, Elias R; Krejza, Jaroslaw

    2009-03-01

    To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

  19. Diabetic mastopathy: a diagnostic challenge in breast sonography.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Triggiani, Vincenzo; Rella, Leonarda; Cornacchia, Ilaria; Serio, Gabriella; Ianora, Amato Antonio Stabile; Angelelli, Giuseppe

    2015-02-01

    Our purpose was to retrospectively evaluate the incidence and morphologic features of diabetic mastopathy in a group of patients with diabetes, searching for specific sonographic characteristics of diabetic mastopathy. One hundred twenty diabetic patients underwent breast clinical examination, mammography, and sonography. All detected breast lesions were confirmed histopathologically. Breast lesions were found in 11 of the 120 patients (9%), including two cases of invasive ductal carcinomas and nine cases of diabetic mastopathy. In seven of those nine cases (77%), diabetic mastopathy appeared as a hypoechoic solid mass with irregular margins, inhomogeneous echotexture, and marked posterior shadowing. In the other two cases (23%), it appeared as a mildly inhomogeneous, hypoechoic solid mass. Diabetic mastopathy is a diagnostic challenge and needs to be suspected in all patients with diabetes mellitus. Imaging features are nonspecific and highly susggestive on breast sonography in most cases. Core-needle biopsy confirmation remains mandatory for a definitive diagnosis. © 2015 Wiley Periodicals, Inc.

  20. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    Science.gov (United States)

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.

    2010-01-01

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. PMID:20737145

  1. Fetal tracheolaryngeal airway obstruction: prenatal evaluation by sonography and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Courtier, Jesse; Poder, Liina; Wang, Zhen J.; Westphalen, Antonio C.; Yeh, Benjamin M.; Coakley, Fergus V. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States)

    2010-11-15

    We reviewed the sonographic and MRI findings of tracheolaryngeal obstruction in the fetus. Conditions that can cause tracheolaryngeal obstruction include extrinsic causes such as lymphatic malformation, cervical teratoma and vascular rings and intrinsic causes such as congenital high airway obstruction syndrome (CHAOS). Accurate distinction of these conditions by sonography or MRI can help facilitate parental counseling and management, including the decision to utilize the ex utero intrapartum treatment (EXIT) procedure. (orig.)

  2. Thyroid disease in the pediatric patient: emphasizing imaging with sonography

    International Nuclear Information System (INIS)

    Babcock, Diane S.

    2006-01-01

    Thyroid disease does occur in the pediatric patient, and imaging plays an important role in its evaluation. A review is presented of normal development of the thyroid gland, the technique and indications for thyroid sonography, and key imaging features of congenital thyroid disorders (ectopic or absent thyroid, infantile goiter, thyroglossal duct remnants), benign thyroid masses (follicular adenoma, degenerative nodules, colloid and thyroid cysts), malignant masses (follicular, papillary and medullary carcinoma) and diffuse thyroid disease (acute bacterial thyroiditis, Hashimoto's thyroiditis, Grave's disease). (orig.)

  3. Assessment of cutaneous radiation fibrosis by 20 MHz-sonography

    International Nuclear Information System (INIS)

    Gottloeber, P.; Braun-Falco, B.; Plewig, G.; Kerscher, M.; Peter, R.U.; Nadeshina, N.

    1996-01-01

    Radiation fibrosis is the cardinal symptom of the chronicle stage of the cutaneous radiation syndrome. The degree of cutaneous fibrosis can clinically be estimated by palpation. High-frequency 20 MHz-sonography is an established, noninvasive procedure, which renders an exact determination of skin thickness and additionally densitometry is possible. We investigated 15 survivors of the Chernobyl accident in 1986, who developed symptoms of the chronic stage of the cutaneous radiation syndrome. We determined skin thickness and echogenicity of skin areas clinically suggestive of radiation fibrosis before, during and after treatment. 20 MHz-sonography showed a distinct enlargement of the echorich corium and a reduction of the subcutaneous fatty tissue in comparison with the unaffected, contralateral skin, here demonstrating typical features of radiation fibrosis, namely dermal fibrosis and reactive pseudoatrophy and fatty tissue. The histology presented an increase and swelling of the collagen fibers and atypical fibroblastic cells. The patients received treatment with low-dose interferon y (Polyfcron R , 3 x 50μg s.C., three times per week) up to 30 months. A marked reduction of skin thickness and echogenicity reaching nearly normal values could be observed. We conclude that 20 MHz-sonography is an easy to apply, noninvasive, well established procedure to quantify cutaneous radiation fibrosis and to assess therapeutic outcome

  4. Interobserver variability of sonography for prediction of placenta accreta.

    Science.gov (United States)

    Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M

    2014-12-01

    The sensitivity of sonography to predict accreta has been reported as higher than 90%. However, most studies are from single expert investigators. Our objective was to analyze interobserver variability of sonography for prediction of placenta accreta. Patients with previa with and without accreta were ascertained, and images with placental views were collected, deidentified, and placed in random sequence. Three radiologists and 3 maternal-fetal medicine specialists interpreted each study for the presence of accreta and specific findings reported to be associated with its diagnosis. Investigator-specific sensitivity, specificity, and accuracy were calculated. κ statistics were used to assess variability between individuals and types of investigators. A total of 229 sonographic studies from 55 patients with accreta and 56 control patients were examined. Accuracy ranged from 55.9% to 76.4%. Of imaging studies yielding diagnoses, sensitivity ranged from 53.4% to 74.4%, and specificity ranged from 70.8% to 94.8%. Overall interobserver agreement was moderate (mean κ ± SD = 0.47 ± 0.12). κ values between pairs of investigators ranged from 0.32 (fair agreement) to 0.73 (substantial agreement). Average individual agreement ranged from fair (κ = 0.35) to moderate (κ = 0.53). Blinded from clinical data, sonography has significant interobserver variability for the diagnosis of placenta accreta. © 2013 by the American Institute of Ultrasound in Medicine.

  5. Radiology of the male breast. Radiologische Diagnostik der maennlichen Brustdruese. Mammographie, Sonographie, pathohistologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Penz, T; Strasser, K [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Toetsch, M [Innsbruck Univ. (Austria). Inst. fuer Pathologische Anatomie

    1991-09-01

    61 men with breast enlargement underwent mammography; complementary sonography was performed in 34 cases. Diagnoses included gynaecomastia in 53 cases, pseudogynaecomastia in 9 cases, 3 carcinomas, 2 inflammatory lesions and 1 lipoma. Mammography and sonography can differentiate reliably true gynaecomastia from pseudogynaecomastia. Gynaecomastia and especially inflammatory lesions may not always be readily differentiated from carcinoma. Sonography can be helpful by demonstrating hyperreflexive glandular tissue, whereas carcinomas are usually hypoechoic. (orig./GDG).

  6. Sonography as an initial study in patients with suspected ureteral stone

    International Nuclear Information System (INIS)

    Lee, Jae Gue; Lim, Joo Won; Ko, Young Tae; Lee, Dong Ho; Lee, Hye Won; Oh, Joo Hyeong; Yoon, Yup; Lee, Sun Ju

    1999-01-01

    To evaluate the usefulness of sonography as an initial study in patients with suspected ureteral stone. We have undertaken a prospective study for 106 patients with suspected ureteral stone during 15 months. All the patients subsequently underwent urography at a mean interval of 1.8 days after the abdominopelvic sonography. We had only a clinical impression at the sonography and didn't refer to the other study such as KUB. We observed the degree of hydronephrosis using a grading system by Ellenbogen et aland location and size of stone. Seventy four patients had ureteral stone disease. The sonographic findings of these 74 patients showed a stone with hydronephrosis in 61 patients, a stone without hydronephrosis in 9, only hydronephrosis without stone in 2, and unremarkable finding in 2. In 3 of the remaining 32 patients, sonography showed hydronephrosis without stone. Locations of stone were 9 patients of ureteropelvic junction(UPJ), 19 of proximal ureter, 30 of distal ureter, and 16 of ureterovesical junction(UVJ). The sensitivity of sonography for stone was 95% and the specificity was 100%. When a ureteral stone was present, ipsilateral hydronephrosis was detected in 85% of cases on sonography. When only hydronephrosis without stone was detected on sonography, a ureteral stone was diagnosed in 2(40%) of 5 patients. Mean discrepancy of stone size between sonography and KUB was 3.1mm and stone size on sonography was larger. Grade of hydronephrosis between sonography and urography was the same in 32(59%) of 54 patients, whose stones were not expelled until urography after sonography. Sonography could be used as an initial study in patients with suspected ureteral stone.

  7. Radiofrequency Ablation Assisted by Real-Time Virtual Sonography and CT for Hepatocellular Carcinoma Undetectable by Conventional Sonography

    International Nuclear Information System (INIS)

    Nakai, Motoki; Sato, Morio; Sahara, Shinya; Takasaka, Isao; Kawai, Nobuyuki; Minamiguchi, Hiroki; Tanihata, Hirohiko; Kimura, Masashi; Takeuchi, Nozomu

    2009-01-01

    Real-time virtual sonography (RVS) is a diagnostic imaging support system, which provides the same cross-sectional multiplanar reconstruction images as ultrasound images on the same monitor screen in real time. The purpose of this study was to evaluate radiofrequency ablation (RFA) assisted by RVS and CT for hepatocellular carcinoma (HCC) undetectable with conventional sonography. Subjects were 20 patients with 20 HCC nodules not detected by conventional sonography but detectable by CT or MRI. All patients had hepatitis C-induced liver cirrhosis; there were 13 males and 7 females aged 55-81 years (mean, 69.3 years). RFA was performed in the CT room, and the tumor was punctured with the assistance of RVS. CT was performed immediately after puncture, and ablation was performed after confirming that the needle had been inserted into the tumor precisely. The mean number of punctures and success rates of the first puncture were evaluated. Treatment effects were evaluated with dynamic CT every 3 months after RFA. RFA was technically feasible and local tumor control was achieved in all patients. The mean number of punctures was 1.1, and the success rate of the first puncture was 90.0%. This method enabled safe ablation without complications. The mean follow-up period was 13.5 month (range, 9-18 months). No local recurrence was observed at the follow-up points. In conclusion, RFA assisted by RVS and CT is a safe and efficacious method of treatment for HCC undetectable by conventional sonography.

  8. [Fetal neurosonography using 3-dimensional multiplanar sonography].

    Science.gov (United States)

    Chaoui, R; Heling, K S; Kainer, F; Karl, K

    2012-04-01

    This review focuses on the examination of the fetal brain, using three-dimensional (3D) ultrasound and the multiplanar rendering mode (MPR). The routine examination of the brain is achieved with axial planes but a dedicated fetal neurosonogram requires additional coronal and sagittal views, in order to provide a complete view of the different brain structures. Because these planes are difficult to obtain under many conditions, the present paper shows how 3D MPR allows one to obtain 1 or multiple reconstructed images from a digital volume. The display can be either as orthogonal planes, tomographic planes with parallel slices or as one single plane of the region of interest, which can be selected by the examiner. This approach allows easily the demonstration of the corpus callosum, the cerebellar vermis, the three-horn view, the foetal hippocampus and other regions. In addition, early neurosonography of the developing brain from the 7th week of pregnancy onwards can be achieved. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Transcranial sonography and functional imaging in glucocerebrosidase mutation Parkinson disease.

    Science.gov (United States)

    Barrett, M J; Hagenah, J; Dhawan, V; Peng, S; Stanley, K; Raymond, D; Deik, A; Gross, S J; Schreiber-Agus, N; Mirelman, A; Marder, K; Ozelius, L J; Eidelberg, D; Bressman, S B; Saunders-Pullman, R

    2013-02-01

    Heterozygous glucocerebrosidase (GBA) mutations are the leading genetic risk factor for Parkinson disease, yet imaging correlates, particularly transcranial sonography, have not been extensively described. To determine whether GBA mutation heterozygotes with Parkinson disease demonstrate hyperechogenicity of the substantia nigra, transcranial sonography was performed in Ashkenazi Jewish Parkinson disease subjects, tested for the eight most common Gaucher disease mutations and the LRRK2 G2019S mutation, and in controls. [(18)F]-fluorodeoxyglucose or [(18)F]-fluorodopa positron emission tomography is also reported from a subset of Parkinson disease subjects with heterozygous GBA mutations. Parkinson disease subjects with heterozygous GBA mutations (n = 23) had a greater median maximal area of substantia nigral echogenicity compared to controls (n = 34, aSNmax = 0.30 vs. 0.18, p = 0.007). There was no difference in median maximal area of nigral echogenicity between Parkinson disease groups defined by GBA and LRRK2 genotype: GBA heterozygotes; GBA homozygotes/compound heterozygotes (n = 4, aSNmax = 0.27); subjects without LRRK2 or GBA mutations (n = 32, aSNmax = 0.27); LRRK2 heterozygotes/homozygotes without GBA mutations (n = 27, aSNmax = 0.28); and GBA heterozygotes/LRRK2 heterozygotes (n = 4, aSNmax = 0.32, overall p = 0.63). In secondary analyses among Parkinson disease subjects with GBA mutations, maximal area of nigral echogenicity did not differ based on GBA mutation severity or mutation number. [(18)F]-fluorodeoxyglucose (n = 3) and [(18)F]-fluorodopa (n = 2) positron emission tomography in Parkinson disease subjects with heterozygous GBA mutations was consistent with findings in idiopathic Parkinson disease. Both transcranial sonography and positron emission tomography are abnormal in GBA mutation associated Parkinson disease, similar to other Parkinson disease subjects. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Deginerative changes of femoral articular cartilage in the knee : comparative study of specimen sonography and pathology

    International Nuclear Information System (INIS)

    Park, Ju Youn; Hong, Sung Hwan; Sohn, Jin Hee; Wee, Young Hoon; Chang, Jun Dong; Park, Hong Seok; Lee, Eil Seoung; Kang Ik Won

    2001-01-01

    To determine the sonographic findings of degenerative change in femoral articular cartilage of the knee by comparative study of specimen sonography and pathology. We obtained 40 specimens of cartilage of the femur (20 medial and 20 lateral condylar) from 20 patients with osteoarthritis of the knee who had undergone total knee replacement. The specimens were placed in a saline-filled container and sonography was performed using a 10-MHz linear transducer. Sonographic abnormalities were evaluated at the cartilage surface, within the cartilage, and at the bone-cartilage interface, and were compared with the corresponding pathologic findings. In addition, cartilage thickness was measured at a representative portion of each femoral cartilage specimen and was compared with the thickness determined by sonography. 'Dot' lesions, irregularity or loss of the hyperechoic line, were demonstrated by sonography at the saline-cartilage interface of 14 cartilages. Pathologic examination showed that these findings corresponded to cleft, detachment, erosion, and degeneration. Irregularities in the hyperechoic line at the bone-cartilage interface were revealed by sonography in eight cartilages and were related to irregularity or loss of tidemark, downward displacement of the cartilage, and subchondral callus formation. Dot lesions, corresponding to cleft and degeneration, were noted within one cartilage. Cartilage thickness measured on specimen and by sonography showed no significant difference (p=0.446). Specimen sonography suggested that articular cartilage underwent degenerative histopathological change. Cartilage thickness measured by sonography exactly reflected real thickness

  11. Re-Appraising the Role of Sonography in Pediatric Acute Abdominal Pain

    OpenAIRE

    Lin, Wei-Ching; Lin, Chien-Heng

    2013-01-01

    Objective Most pediatric emergency department (ED) visits are due to acute abdominal pain. Sonography is a reliable technique for differential diagnosis. The objective of this study was to re-appraise the role of sonography in evaluating acute abdominal pain in children. Methods Retrospective chart review of children aged

  12. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  13. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography

    Science.gov (United States)

    2010-05-01

    worldwide. Peer Reviewed Title: Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular Sonography Journal Issue: Western...Preferred Citation: Thompson D, Stanescu C, Pryor P, Laselle B. Retrobulbar Hematoma from Warfarin Toxicity and the Limitations of Bedside Ocular...nontrauamtic retrobulbar hematoma associated with warfarin toxicity. The application and limitations of focused bedside ocular sonography for this

  14. Can sonography define the chemical composition of gall stones

    International Nuclear Information System (INIS)

    Frentzel-Beyme, B.; Faehndrich, R.; Arnan-Thiele, B.

    1983-01-01

    Eight sonographic patterns caused by gall stones are described. In an attempt to explain these different appearances, 62 stones were analysed chemically and physically. The chemical composition of the stones did not correlate with their sonographic pattern. Cholesterol stones cannot be recognised as such by sonography. The formation of an acoustic shadow depends largely on the position of the stone within the acoustic beam. It therefore follows that the examination must be done by keeping the focal plane of the transducer in proper relationship to the stone. (orig.) [de

  15. Thyroid disease in the pediatric patient: emphasizing imaging with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Babcock, Diane S. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2006-04-15

    Thyroid disease does occur in the pediatric patient, and imaging plays an important role in its evaluation. A review is presented of normal development of the thyroid gland, the technique and indications for thyroid sonography, and key imaging features of congenital thyroid disorders (ectopic or absent thyroid, infantile goiter, thyroglossal duct remnants), benign thyroid masses (follicular adenoma, degenerative nodules, colloid and thyroid cysts), malignant masses (follicular, papillary and medullary carcinoma) and diffuse thyroid disease (acute bacterial thyroiditis, Hashimoto's thyroiditis, Grave's disease). (orig.)

  16. The value of computer tomography and sonography in the investigation of the pancreas

    International Nuclear Information System (INIS)

    Lackner, K.; Frommhold, H.; Grauthoff, H.; Moedder, U.; Heuser, L.; Braun, G.; Buurman, R.; Scherer, K.; Hamburg Univ.; Koeln Univ.

    1980-01-01

    Three hundred and five patients were examined by computer tomography and sonography. In 117 patients no abnormalities were found in the pancreas. The accuracy of computer tomography was 87%, of sonography 85%. In 41 patients the presence of a carcinoma of the pancreas was confirmed histologically. In this group the sensitivity of computer tomography was 83%, of sonography 85%. Thirty-four patients suffered from acute pancreatitis. In this group sensitivity of the two methods was equal at 79%. 113 patients had changes of chronic pancreatitis. Sensitivity of computer tomography was 84%, of sonography 70%. Computer tomography is better at demonstrating calcification in the pancreas. Atrophy of the pancreas cannot be diagnosed by sonography. (orig.) [de

  17. Clinical experience with contrast infusion sonography as an Essure confirmation test.

    Science.gov (United States)

    Connor, Viviane F

    2011-06-01

    The purpose of this study was to assess the clinical experience, including the feasibility, safety, compliance, and efficacy, of contrast infusion sonography as an Essure (Conceptus Inc, Mountain View, CA) confirmation test. A retrospective chart review and telephone survey were conducted at an academic multispecialty group. The study participants were women with Essure intervention who underwent contrast infusion sonography, transvaginal sonography, and hysterosalpingography as Essure confirmation tests. The main outcome measures included the feasibility, safety, compliance, and efficacy of contrast infusion sonography as a first-line Essure confirmation test. A total of 118 women had successful bilateral Essure placement. Of the 63 who consented to contrast infusion sonography, 53 (84.1%) had proper bilateral placement and tubal occlusion and were encouraged to rely on Essure. Four were suspected of having unilateral tubal patency; hysterosalpingography in 2 confirmed bilateral tubal occlusion, and 2 were noncompliant with second-line hysterosalpingography. Three patients suspected of having unsatisfactory or uncertain placement on initial transvaginal sonography were encouraged to undergo hysterosalpingography in lieu of contrast infusion sonography, which confirmed unsatisfactory placement in 2 and proper placement and occlusion in 1. Three contrast infusion sonographic procedures could not be completed because of technical issues; therefore, contrast infusion sonography was feasible in 95.2% of the patients (60 of 63). No notable adverse events occurred. Only 17 patients were noncompliant with any confirmation test, yielding an overall compliance rate of 86% (101 of 118). No pregnancies occurred during 669 woman-months of follow-up. The average reimbursement for contrast infusion sonography was US$251.78. Preliminary clinical data suggest that contrast infusion sonography is a feasible, safe, and accurate Essure confirmation test, which is well accepted by

  18. Use of chest sonography in acute-care radiology☆

    Science.gov (United States)

    De Luca, C.; Valentino, M.; Rimondi, M.R.; Branchini, M.; Baleni, M. Casadio; Barozzi, L.

    2008-01-01

    Diagnosis of acute lung disease is a daily challenge for radiologists working in acute-care areas. It is generally based on the results of chest radiography performed under technically unfavorable conditions. Computed tomography (CT) is undoubtedly more accurate in these cases, but it cannot always be performed on critically ill patients who need continuous care. The use of thoracic ultrasonography (US) has recently been proposed for the study of acute lung disease. It can be carried out rapidly at the bedside and does not require any particularly sophisticated equipment. This report analyzes our experience with chest sonography as a supplement to chest radiography in an Emergency Radiology Unit. We performed chest sonography – as an adjunct to chest radiography – on 168 patients with acute chest pathology. Static and dynamic US signs were analyzed in light of radiographic findings and, when possible, CT. The use of chest US improved the authors' ability to provide confident diagnoses of acute disease of the chest and lungs. PMID:23397048

  19. Muscle sonography in six patients with hereditary inclusion body myopathy

    International Nuclear Information System (INIS)

    Adler, Ronald S.; Garolfalo, Giovanna; Paget, Stephen; Kagen, Lawrence

    2008-01-01

    To evaluate the morphological changes of muscle with sonography in six patients affected by hereditary inclusion body myopathy (HIBM). We studied a group of six Persian Jews diagnosed with HIBM. All were homozygous for the GNE mutation M712T. Ultrasonographic examinations of the quadriceps femoris and hamstring muscle groups were performed. A follow-up ultrasound examination was performed, after an interval of 3 years, in four of these patients. Muscles were assessed subjectively as to echogenicity, determined by gray-scale assessment, and loss of normal muscle morphology. Power Doppler sonography (PDS) was used to assess vascularity. A sonographic finding of central atrophy and peripheral sparing resulting in a target-like appearance was noted in the hamstring compartment of all six patients. The quadriceps compartment also showed involvement of the rectus femoris of all patients, which, in some cases, was the only muscle involved in the quadriceps. Vascularity was markedly reduced in the affected areas, with blood flow demonstrated in the peripherally spared areas. The severity of atrophy increased with disease duration. In this case series, we describe a new sonographic finding as well as document progression of HIBM disease, which has generally been described as quadriceps sparing. The myopathic target lesion, as well as isolated rectus femoris atrophy, may provide a useful adjunct to disease diagnosis. (orig.)

  20. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  1. Transvaginal sonography in abnormal uterine bleeding and correlation to hysteroscopy

    International Nuclear Information System (INIS)

    Saeed, S.; Shah, S.; Ali, H.; Khan, S.; Ehsan, N.; Ahmed, S.Z.

    2017-01-01

    To correlate results of Transvaginal sonography with those of hysteroscopy and biopsy in abnormal uterine bleeding to estimate the accuracy and analytical values of non-invasive transvaginal sonography in abnormal uterine bleeding. Methodology: This cross-sectional Study was carried out at BMCH, Quetta, Balochistan, Pakistan from March 2013 to February 2014 and included 200 patients of abnormal uterine bleeding. Exclusion criteria were pregnancy, virginity, local bleeding of perineal or vaginal origin. Hysteroscopy and biopsy and Transvaginal Ultrasound (TVS) were performed in all. Result: The most common type of bleeding was found to be menorrhagia in 39% while the least common type was postmenopausal bleeding in 9%. Mean endometrial thickness was 11.64 mm and it was noted that at less than 14mm thickness no serious pathology was found. Sensitivity of TVS for endometrial hyperplasia was found to be 66.66% while specificity was 100%. Positive analytical value was 100% while negative value was 100%. Overall sensitivity calculated for TVS was 94.44%, specificity 98.55%, PPV was 81.93% and NPV 98.55%. Conclusion: Sensitivity and specificity of TVS were lower than hysteroscopy and biopsy but the difference was not significant. TVS can be used as first line investigation while hysteroscopy and biopsy may be left for cases of high risk or in those cases where some positive findings could be found on TVS. (author)

  2. Diagnosis of brain death by transcranial Doppler sonography.

    Science.gov (United States)

    Bode, H; Sauer, M; Pringsheim, W

    1988-12-01

    The blood flow velocities in the basal cerebral arteries can be recorded at any age by transcranial Doppler sonography. We examined nine children with either initial or developing clinical signs of brain death. Soon after successful resuscitation increased diastolic flow velocities indicated a probable decrease in cerebrovascular resistance; this was of no particular prognostic importance. As soon as there was a clinical deterioration, there was a reduction in flow velocities with retrograde flow during early diastole, probably due to an increase in cerebrovascular resistance; this indicated a doubtful prognosis. In eight of the nine children with clinical signs of brain death a typical reverberating flow pattern was found, which was characterised by a counterbalancing short forward flow in systole and a short retrograde flow in early diastole. This indicated arrest of cerebral blood flow. One newborn showed normal systolic and end diastolic flow velocities in the basal cerebral arteries for two days despite clinical and electroencephalographic signs of brain death. Shunting of blood through the circle of Willis without effective cerebral perfusion may explain this phenomenon. No patient had the typical reverberating flow pattern without being clinically brain dead. Transcranial Doppler sonography is a reliable technique, which can be used at the bedside for the confirmation or the exclusion of brain death in children in addition to the clinical examination.

  3. Noninvasive Prenatal Diagnosis of Hypohidrotic Ectodermal Dysplasia by Tooth Germ Sonography.

    Science.gov (United States)

    Wünsche, S; Jüngert, J; Faschingbauer, F; Mommsen, H; Goecke, T; Schwanitz, K; Stepan, H; Schneider, H

    2015-08-01

    Hypohidrotic ectodermal dysplasia, a potentially life-threatening heritable disorder, may be recognized already in utero by characteristic features such as oligodontia and mandibular hypoplasia. As therapeutic options and prognosis depend on the time point of diagnosis, early recognition was attempted during routine prenatal ultrasound examinations. Fetuses of nine pregnant women (one triplet and eight singleton pregnancies) with family histories of hypohidrotic ectodermal dysplasia were investigated by sonography between the 20th and 24th week of gestation. In 4 male and 2 female fetuses reduced amounts of tooth germs were detected, whereas 5 fetal subjects showed the normal amount. Three-dimensional ultrasound evaluation revealed mandibular hypoplasia in 5 of the 6 fetuses with oligodontia. Molecular genetic analysis and/or clinical findings after birth confirmed the prenatal sonographic diagnosis in each subject. In subjects with a family history of hypohidrotic ectodermal dysplasia, the diagnosis of this rare condition can be established noninvasively by sonography in the second trimester of pregnancy. Early recognition of the disorder may help to prevent dangerous hyperthermic episodes in infancy and may allow timely therapeutic interventions. © Georg Thieme Verlag KG Stuttgart · New York.

  4. 3-D sonography for diagnosis of disk dislocation of the temporomandibular joint compared with MRI.

    Science.gov (United States)

    Landes, Constantin A; Goral, Wojciech A; Sader, Robert; Mack, Martin G

    2006-05-01

    This study determines the value of three-dimensional (3-D) sonography for the assessment of disk dislocation of the temporomandibular joint (TMJ). Sixty-eight patients (i.e.,136 TMJ) with clinical dysfunction were examined by 272 sonographic 3-D scans. An 8- to 12.5-MHz transducer, angulated by step-motor, was used after picking a volume box on 2-D scan; magnetic resonance imaging followed immediately. Every TMJ was scrutinized in closed- and open-mouth position for normal or dislocated disk position. Fifty-three patients had complete data sets, i.e., 106 TMJ, 212 examinations. Sonographic examination took 5 min, with 74% specificity (62% closed-mouth; 85% open-mouth); sensitivity 53% (62/43%); accuracy 70% (62/77%); positive predictive value 49% (57/41%); and negative predictive value 77% (67/86%). This study encourages more research on the diagnostic capacity of 3-D TMJ sonography, with the advantage of multidimensional joint visualization. Although fair in specificity and negative predictive value, sensitivity and accuracy may ameliorate with future higher-sound frequency, real-time 3-D viewing and automated image analysis.

  5. Sonography for diagnosis of benign and malignant tumors of the nose and paranasal sinuses.

    Science.gov (United States)

    Liu, Jun-jie; Gao, Yong; Wu, Ya-Fei; Zhu, Shang-Yong

    2014-09-01

    The purpose of this study was to demonstrate the reliability of sonography for diagnosis of nose and paranasal sinus tumors. Ninety-six consecutive patients with tumors underwent sonography and computed tomography (CT) before surgical treatment. Tumor detectability and imaging findings were evaluated independently and then compared with pathologic findings. Of 96 tumors, 75 were detected by sonography, for a detectability rate of 78.1%; 93 tumors were detected by CT, for a detectability rate of 96.9%. By comparison, sonography showed a trend toward higher detectability of nasal vestibular tumors than CT (87.5% for sonography versus 50.0% for CT) and small lumps on the wing of the nose (78.8% for sonography versus 33.3% for CT). Among the sonographic features, boundary, shape, internal echo, calcification, bone invasion, vascular pattern, and cervical lymph node metastasis all had significantly positive correlations with malignancy (P benign and malignant tumors of the nose and paranasal sinuses. Consequently, sonography has high value for diagnosis of benign and malignant tumors of the nose and paranasal sinuses, especially for nasal vestibular tumors and small lumps on the wing of the nose. © 2014 by the American Institute of Ultrasound in Medicine.

  6. Sonography in the 29th Olympic and Paralympic Games: a retrospective analysis.

    Science.gov (United States)

    He, Wen; Xiang, Dong-ying; Dai, Jian-ping

    2011-01-01

    The purpose of this study was to evaluate the application of sonography at the polyclinic of the Olympic/Paralympic village during the Olympic/Paralympic Games. We retrospectively reviewed 759 consecutive patients who underwent sonography at the ultrasound division of the polyclinic in the Olympic/Paralympic village from July 20, 2008, to September 20, 2008. Prevalence of emergency sonography after sports injury and non-sports-related urgent conditions during the games was analyzed. The benefit of sonographic services in large sporting events was discussed. There were 759 patients (484 athletes, 101 coaches, 88 team officials, and 86 volunteers; 462 men and 297 women) in the ultrasound division at the polyclinic. The indications for sonography included abdominal pain (315 cases, 41.50%), muskuloskeletal disorders (228 cases, 30.04%), gynecology related (104 cases, 13.70%), cardiac conditions (49 cases, 6.46%), small parts (29 cases, 3.82%), and vascular problems (34 cases, 4.48%). The rates of positive findings on sonography were 46.03% in the abdomen, 70.17% in musculoskeleton, 41.34% in gynecology, 10.20% in the heart, 75.86% in small parts, and 38.24% in vessels, respectively. Sonography plays an important role in the medical services at the polyclinic in the Olympic/Paralympic village. The benefits of sonography in such large sporting events are accuracy, fast result, portability, and noninvasiveness. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. The Benefit of Sonography in Pregnancy-associated Breast Cancer

    International Nuclear Information System (INIS)

    Son, Eun Ju; Oh, Ki Keun; Kim, Eun Kyung

    2005-01-01

    To evaluate the sonographic, mammographic and MRI features of pregnancy-associated breast cancer with the major focus on the sonographic benefit in a diagnosis of pregnancy associated breast cancer. From 1998 to 2002, sonography was performed on a total 7 patients (age 23 to 38 years), who were pathologically diagnosed with breast cancer during pregnancy. Six of those patients underwent mammography. Five patients underwent a breast MRI, preoperatively. The radiological findings were evaluated retrospectively. Six patients underwent surgery and 1 patient underwent a core biopsy and chemotherapy. The histological, nuclear grading and pathological staging were evaluated. The sonographic findings showed a mass with irregular shapes (n=6), irregular margins (n=6), a non-parallel orientation (n=5), complex echo patterns (n=5). Associated findings could be observed in 3 patients, including Cooper's ligament thickening (n=2), edema (n=2), skin thickening (n=1) and axillary lymphadenopathy (n=3). The sonographic findings were positive and showed masses in 6 patients. All the patients had a dense breast in mammography. The mammographic findings included masses (n=4), masses with microcalcifications (n=2), masses with axillary lymphadenopathy (n=3), calcifications alone (n=1), an asymmetric density alone (n=1), extremely dense breasts with negative findings (n=2). A breast MRI showed an irregular shaped mass (n=4) with a rim-like enhancement (n=3), linear ductal enhancement without a mass (n= 1), and the time intensity cure revealed the typical pattern and level of enhancement in the carcinoma. Sonography is a valuable tool for diagnosing pregnancy-associated breast cancer. However, mammography should be performed if there is a suspicious lesion on sonography in order to confirm the pregnancy-associated breast cancer. Mammography has a lower sensitivity during pregnancy due to the physiologic changes in the breasts. However, calcifications and associated findings are helpful

  8. Sonography and electrodiagnosis in carpal tunnel syndrome diagnosis, an analysis of the literature

    International Nuclear Information System (INIS)

    Seror, P.

    2008-01-01

    We present a review of the international literature concerning sonography for the diagnosis of carpal tunnel syndrome (CTS). Analysis of the results and comparison with electrodiagnostic data provide a sensible albeit personal view on the relevance of sonography and whether it competes or is complementary to electrodiagnosis (EDX). Although EDX is considered as the gold standard for CTS diagnosis, one author chose surgical results to define CTS. The normal and threshold mean values for sonography are particularly variable from one study to another. The standard deviation (S.D.), when compared to mean values, makes normal and abnormal data overlap considerably and produces many false negatives when the specificity is high, and many false positives when the sensitivity is high. In fact, sonography is non-interpretable in only 10 to 15% of the population, and it affirms the median nerve lesion at the wrist in 55% of cases when EDX does it in more than 90% with common tests. Further more the specificity of sonography leads to a false positive diagnosis in 1 case out of 5 versus 1 out of 40 with EDX. The main conclusion is that there is no competition but rather a complementarity between sonography and EDX: sonography is certainly an efficient imaging technique but cannot replace proper EDX performed for upper limb paresthesiae. Namely, sonography can answer only one out of the 8 questions a complete EDX answer: Are sonographic images compatible with a median nerve lesion at the wrist? The answer to this solely question can be obtain with a partial EDX using a single conduction test (motor or sensitive), then duration and cost will be comparable to sonography but will be both more sensitive and specific. Finally, one must kept in mind that the final aim of all examinations in CTS is to determine the cause(s) of upper limb paresthesiae, not simply if there is a median nerve lesion at wrist or not

  9. Duplex sonography of the near-surface leg veins; Duplexsonographie der oberflaechlichen Beinvenen

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, E.

    2007-07-01

    The book contains the following contributions: The ultrasonograph, selection of the ultrasonic transducer, anatomy of the near-surface vein system, physiology of the near-surface vein system, varicose status classification, systematics of the duplex sonography of near-surface leg veins, provocational maneuver for the duplex sonographic varicose diagnostics, exploration of vena saphena parva, perforans veins, side branches, phlebitis, sonography for varicose therapy, postsurgical sonography, deep leg veins, examination of near-surface leg veins for the pathology of the deep vein system, differential diagnostic clarification of leg oedema from the phlebologic-lymphological view, diagnostic side features along the near-surface leg veins.

  10. Fatty liver: prospective comparative study with sonography and CT

    International Nuclear Information System (INIS)

    Kim, Sung Jin; Kim, Y. M.; Kim, W. S.; Choi, B. I.; Lee, J. S.; Han, C. K.; Kim, C. W.

    1990-01-01

    To identify the reasonable criteria in detection of the degree of Fatty liver, we prospectively evaluated sonograms and CT scans in 33 Patients With bright liver on sonography. On sonograms, we analyzed the echogenicity of the liver, acoustic attenuation, and visualization of the portal vein and the diaphragm, Each criterion was scored from 0 to 2. CT criterion for fatty liver was assessed by the attenuation difference between the liver and the spleen on nonocontrast CT scans, The average sonographic grade for CT Grade I was 1.3, Grade II was 2.1,and Grade III was 2.8. The accurate detection rate of each sonographic grade was as follows, Grade

  11. The forgotten organ: Contrast enhanced sonography of the spleen

    International Nuclear Information System (INIS)

    Goerg, Christian

    2007-01-01

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration

  12. The forgotten organ: Contrast enhanced sonography of the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35043 Marburg/Lahn (Germany)], E-mail: goergc@med.uni-marburg.de

    2007-11-15

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration.

  13. Contrast infusion sonography in the post-Essure setting.

    Science.gov (United States)

    Connor, Viviane

    2008-01-01

    To compare contrast infusion sonogram (CIS) to hysterosalpingogram (HSG) for use as a 3-month confirmation test after Essure. Pilot study (Canadian Task Force classification II-2). Healthy women in an academic multispecialty group. Seventeen women desiring permanent sterilization who had had successful bilateral Essure placement within 12 weeks. Contrast infusion sonography was performed and immediately followed by an HSG at the same appointment, between 1 and 12 weeks after Essure placement. To determine how well microinsert location and tubal status can be assessed with CIS, an adaptation of hysterosalpingo contrast sonography (HyCoSy), when compared with sequential HSG. Tubal occlusion rate within 4 to 8 weeks after Essure placement was also noted. All microinserts were readily identified with ultrasound, and location was accurately determined. In all patients (100%) with at least 1 tube patent on HSG, patency was also demonstrated on CIS by visualizing real-time flow in the tube or the presence of dye in the cul-de-sac or adnexa. There were no significant adverse events, and pain ratings were similar for both tests. The majority (88%) of patients felt strongly that they would prefer to have a 3-month confirmation test performed in the gynecologist's office rather than an unfamiliar radiologic facility. Tubal occlusion was noted on both CIS and HSG in 82% of patients before 12 weeks. Based on this pilot study with a small sample, CIS, an adaptation of HyCoSy, has comparable accuracy to HSG in the post-Essure setting. The safety, convenience, and comfort of an in-office test using ultrasound and a non-iodine-based dye would be a welcome alternative to HSG. There was also a high rate of bilateral fallopian tube occlusion noted on HSG at 4 weeks after Essure.

  14. Differential diagnosis of persistent neonatal jaundice: Role of sonography and scintigraphy

    International Nuclear Information System (INIS)

    Lee, Sun Wha; Ko, Young Tae; Lim, Jae Hoon

    1993-01-01

    The most common causes of conjugated hyperbilirubinaemia after the first or second week of life are neonatal hepatitis and biliary atresia. Since these entities represent variable expressions of same pathologic process and have similar clinical, biochemical, and histologic features, differential diagnosis is extremely difficult. We prospectively studies 28 jaundiced infants by sonography and hepatobiliary scintigraphy. Final diagnoses included 12 biliary atresia and 16 neonatal hepatitis. Visualization of a normal sized common bile duct or gallbladder was compatible with the diagnosis of neonatal hepatitis. Non-visualized or atrophic gallbladder on sonography coupled with non-visualization of bowel activity on scintigraphy was highly suggestive of biliary atresia. We believe that sonography plays a valuable role in the initial evaluation of the infants with persistent neonatal jaundice. The combined use of sonography and hepatobiliary scintigraphy provides the most valuable information in suspected biliary atresia for prompt surgical treatment

  15. Duplex sonography in the planning and evaluation of arteriovenous fistulae for haemodialysis

    International Nuclear Information System (INIS)

    Kerr, S.F.; Krishan, S.; Lapham, R.C.; Weston, M.J.

    2010-01-01

    This paper describes how to perform duplex sonography in the planning and evaluation of arteriovenous fistulae in haemodialysis patients, discusses its roles in these settings, and presents a review of commonly encountered complications.

  16. Using modern teaching strategies to teach upper abdominal sonography to medical students

    Directory of Open Access Journals (Sweden)

    Wei-Chun Cheng

    2013-07-01

    Conclusion: We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives.

  17. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles({+-}2 standard error) in rest and stress states were 136.3({+-}7.2) .deg. , and 145.9({+-}7.0) .deg. for chain cystourethrography and 131.4({+-}5.6) .deg. and 143.4({+-}5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  18. Stress Urinary lncontinence : Comparative Study of Perineal Sonography in Erect Position and Chain Cystourethrograpy

    International Nuclear Information System (INIS)

    Han, Gi Seok; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung; Paick, Jae Seung

    1995-01-01

    Authors investigated the diagnostic value of perineal sonography in erect position for patients with stress urinary incontinence. Perineal sonography and chain cystourethrography were performed in 18 female patients(mean age 51.2) with stress urinary incontinence. The posterior are throvesical angles in stress and rest states were measured in both studies and compared with each other. Mean posteriorurethrovesical angles(±2 standard error) in rest and stress states were 136.3(±7.2) .deg. , and 145.9(±7.0) .deg. for chain cystourethrography and 131.4(±5.6) .deg. and 143.4(±5.9) .deg. for perineal sonography, respectively. The data frorm both studies correlated well with cach other. Perineal sonography inerect position is easy,non-invasive technique and may substitute the chain cystourethrography in the evaluation of the patients with stress urinary in continece

  19. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma

    International Nuclear Information System (INIS)

    Faruque, A. V.; Qazi, S. H.; Khan, M. A. M.

    2013-01-01

    Objective: To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. Methods: The retrospective study covered 10 years, from January 1, 2000 to December 31, 2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Results: Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonography had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Conclusions: Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be

  20. Specific preoperative diagnosis of choledochal cysts by combined sonography and hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Papanicolaou, N.; Abramson, S.J.; Teele, R.L.; Treves, S.

    1985-01-01

    The combined use of sonography and hepatobiliary scintigraphy correctly identified a choledochal cyst preoperatively in seven consecutive infants and children. The high resolution anatomic images provided by sonography coupled with physiologic data on filing of the cyst, biliary patency and liver function derived from radionuclide scanning offer valuable information in the diagnosis and planning of corrective surgery of the cyst and coexisting hepatobiliary anomalies. Invasive diagnostic procedures should be reserved for occasional problematic cases [fr

  1. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    International Nuclear Information System (INIS)

    Schueller-Weidekamm, Claudia; Schueller, Gerd; Aringer, Martin; Weber, Michael; Kainberger, Franz

    2007-01-01

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings

  2. Impact of sonography in gouty arthritis: Comparison with conventional radiography, clinical examination, and laboratory findings

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)]. E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Aringer, Martin [Department of Rheumatology, Internal Medicine III, Medical University of Vienna (Austria); Weber, Michael [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2007-06-15

    Objective: To explore the typical sonographic features of gray-scale and Power Doppler of acute and chronic gouty arthritis in conjunction with radiographic, clinical, and laboratory findings. Materials and methods: All hand, finger, and toe joints of 19 patients with acute and chronic gout were examined with gray-scale and Power Doppler sonography. The number and size of bone changes detected with sonography was compared to radiographic findings. Vascularization of the synovial tissue was scored on Power Doppler (grades 0-3), and was compared with clinical appearance, including swelling, tenderness, and redness (grades 0-3). Results: In acute gout, mild to moderate echogenic periarticular nodules with sonotransmission and hypervascularization of the edematous surrounding soft tissue were found. In chronic gout, tophaceous nodules completely blocked transmission of US wave, leading to strong reflexion and dorsal shadowing in a minority of cases. No significant difference in the detection of large bone changes (>2 mm) was found between sonography and radiography. However, gray-scale sonography was significantly more sensitive in the detection of small bone changes (p < 0.001). Power Doppler scores were statistically significantly higher than clinical examination scores (p < 0.001). Discussion: Sonography is superior to radiographs in evaluating small bone changes. The inflammatory process in joints can be better detected with Power Doppler sonography than with clinical examination. Typical sonographic appearance of acute and in particular of chronic gout might provide clues on gouty arthritis that adds to the information available from conventional radiography, clinical, and laboratory findings.

  3. High resolution compression elastography and color doppler sonography in characterization of breast fibroadenoma.

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reu, S; Deak, Z; Hetterich, H; Kolben, T; Reiser, M; Clevert, D A

    2014-01-01

    To evaluate the use of color Doppler sonography and free hand sonoelastography in the assessment of breast fibroadenomas according to their size and shape. From December 2012 to March 2013 women with 16 solid breast masses, classified as BI-RADS category 3 or 4 were examined with B-mode ultrasound, sonoelastography and color Doppler sonography. Lesions were subdivided according to their shape in round, ovoid or macrolobulated and according to their size (fibroadenomas in B-mode sonography could be shown (p = 0.91) and also comparison of Tsukuba-scores and size of masses revealed no significant differences (p = 1.0). Sizes of fibroadenomas ≥2 cm were significantly associated with an increased vascularization of the lesions (p = 0.04) and a macrolobulated appearance in B-mode sonography (p = 0.04). The combination of color Doppler sonography and sonoelastography in addition to B-mode sonography leads to an increased accuracy in distinguishing benign from malignant breast masses and to an improvement in characterization of fibroadenomas independent of their shape or size.

  4. Intratumoral vascularity of experimentally induced VX2 carcinoma : comparison of power doppler sonography and microangiography

    International Nuclear Information System (INIS)

    Park, Kil Sun; Won, Hyung Jin; Seo, Joon Beom; Kim, Tae Kyoung; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To evaluate the usefulness and limitations of power Doppler sonography in determining the tumor vascularity Power Doppler sonography was performed on VX2 carcinomas present in rabbit thighs, and the findings were compared with those of microangiography in an almost identical plane. Tumor vascularity was qualitatively analysed on the basis of tumor vessel distribution and density, and the presence of thick and thin vesels;for a comparison of tumor vascularity as seen on microangiography, tumor blood flow signals shown by power Doppler sonography were graded 3, 2, 1, 0. For quantitative analysis, a comparison was made of the percentage of tumor area occupied by vessels, as shown in each study. Data analysis utilized the Wilcoxon signed-rank test and Spearman correlation test. Mean tumor vascularity scores, as seen on power Doppler sonography and relating to tumor vessel distribution and density, and the presence of thick and thin vessels, were 2.87, 2.73, 2.93 and 2.73, respectively. The means and medians of the percentages of tumor area occupied by vessels were 22.7% and 23.5% and 36.4% and 34.7% on microangiography and power Doppler sonography, respectively. Thus, there was good correlation between these two modes. Power doppler sonography could demonstrate the tumor vascularity on microangiography relatively well but tend to overestimate it

  5. The efficiency of sonography in diagnosing volvulus in neonates with suspected intestinal malrotation.

    Science.gov (United States)

    Zhang, Wenhua; Sun, Hongjun; Luo, Fangqiong

    2017-10-01

    This study is to prospectively evaluate the efficiency of sonography for volvulus diagnosis in neonates with clinically suspected intestinal malrotation.A total of 83 patients with suspected intestinal malrotation who underwent detailed abdominal sonography and upper gastrointestinal contrast study were included. Malrotation was characterized by inversion of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in sonographic examination. The "whirlpool sign" of Color Doppler Sonography was recognized as a characteristic for malrotation with volvulus. The degrees of rotation of the SMV winding around SMA were also detected by sonography. Surgery was performed in patients with sonography diagnosed malrotation.A total of 39 patients were sonographically diagnosed as malrotation which was subsequently confirmed by surgery. The sensitivity and positive predictive value of the sonographic diagnosis were both 100% (39/39). The sensitivity, specificity and accuracy of "whirlpool sign" for the detection of midgut volvulus were 95.2% (20/21), 88.9% (16/18), and 92.3% (36/39), respectively. Greater degrees of rotation (equal or greater than 720°) showed higher risk (odds ratio, 5.0; P volvulus may be used as a potential indicator for intestinal necrosis. In addition, sonography can exclude malrotation and may help the diagnosis of other diseases, such as annular pancreas and duodenal atresia.

  6. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    Science.gov (United States)

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed

  7. Establishment of a course for Focused Assessment Sonography for Trauma

    International Nuclear Information System (INIS)

    Abu-Zidan, Fikri M.; Kazzam, Elsadig E.; Czechowski, Janusz J.; Dittrich, Kenneth

    2005-01-01

    Focused Assessment Sonography for Trauma (FAST) is not widely practiced by Trauma Surgeons in the Middle East despite its international acceptance. A FAST course was established by the Trauma Group at the Faculty of Medicine and Health Sciences at United Arab Emirates (UAE) University aiming to introduce doctors who have limited experience of ultrasound to the basics of FAST. This article summarizes the content of the course; the evaluation of the participants and their recommendations. An 8 hour FAST course was offered to 18 participants in May 2004 in the Faculty of Medicine and Health Sciences, UAE University, Al-Ain, UAE. Lectures with syllabus material were used to cover the following topics: basic ultrasound physics, knobology and sonographic orientation, the FAST scan, chest and cardiac trauma sonographic evaluation, training and credentialing issues. Each participant received 3 hours of hands-on ultrasound instruction. On completion of the course participants responded anonymously to an evaluation questionnaire. All participants responded to the questionnaire (100% response rate). Delegates found the course well organized, relevant, met their needs and encourages them to use FAST in their own practice. The course objectives were met. Participants suggested that including actual patients and the use of animal models improve the practical sessions. Organizing a FAST course is an important step towards recognizing and implementing it in practice. Nevertheless, there is a need for appropriate quality assurance and credentialing guidelines before commencing. (author)

  8. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Quantification of cerebral blood flow via Duplex sonography

    International Nuclear Information System (INIS)

    Vogl, G.; Pohl, P.; Willeit, J.; Aichner, F.

    1987-01-01

    An attempt was made to measure quantitatively the total cerebral blood flow by means of Duplex sonography. In a group of healthy young subjects a median value for total cerebral blood flow was obtained amounting to 469 ml/min ± 30%, repeat measurements yielded a maximum deviation of ± 11%. In three patients the values obtained after severe apoplectic insult due to occlusion of the internal carotid artery were definitely below the value of the group of healthy subjects, whereas the value for the total blood flow was in the upper range of normal values in a patient with occlusion of the a. cerebri media. Comparative measurements of the regional cerebral blood flow with xenon 13 yielded in those patients with occlusion of the internal carotid artery a markedly reduced mean flow and in the patient with occlusion of the a. cerebri media a less markedly reduced mean flow. Regionally reduced perfusion was seen in all the four patients in the range of the clinically and computer tomographically well-known ischaemia zone. Thanks to the simplicity of this sonographic examination method it could be a useful decision parameter in determining the indication for a reconstruction of the carotid artery, especially in asymptotic patients. (orig.) [de

  10. Screen for intracranial dural arteriovenous fistulae with carotid duplex sonography.

    Science.gov (United States)

    Tsai, L-K; Yeh, S-J; Chen, Y-C; Liu, H-M; Jeng, J-S

    2009-11-01

    Early diagnosis and management of intracranial dural arteriovenous fistulae (DAVF) may prevent the occurrence of stroke. This study aimed to identify the best carotid duplex sonography (CDS) parameters for screening DAVF. 63 DAVF patients and 170 non-DAVF patients received both CDS and conventional angiography. The use of seven CDS haemodynamic parameter sets related to the resistance index (RI) of the external carotid artery (ECA) for the diagnosis of DAVF was validated and the applicability of the best CDS parameter set in 20 400 patients was tested. The CDS parameter set (ECA RI (cut-off point = 0.7) and internal carotid artery (ICA) to ECA RI ratio (cut-off point = 0.9)) had the highest specificity (99%) for diagnosis of DAVF with moderate sensitivity (51%). Location of the DAVF was a significant determinant of sensitivity of detection, which was 70% for non-cavernous DAVF and 0% for cavernous sinus DAVF (pdetected abnormality in 92 of 20 400 patients. These abnormalities included DAVF (n = 25), carotid stenosis (n = 32), vertebral artery stenosis (n = 7), intracranial arterial stenosis (n = 6), head and neck tumour (n = 3) and unknown aetiology (n = 19). Combined CDS parameters of ECA RI and ICA to ECA RI ratio can be used as a screening tool for the diagnosis of DAVF.

  11. Sonography-guided percutaneous microwave ablation of intrahepatic primary cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yu Mingan [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Liang Ping, E-mail: Liangping301@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Yu Xiaoling; Cheng Zhigang; Han Zhiyu; Liu Fangyi; Yu Jie [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China)

    2011-11-15

    Objective: To evaluate the efficacy and safety of sonography-guided percutaneous microwave ablation of intrahepatic primary cholangiocarcinoma. Materials and methods: From May 2006 to March 2010, 15 patients (11 men, 4 women; mean age, 57.4 years) with 24 histologically proven intrahepatic primary cholangiocarcinoma lesions (mean tumor size, 3.2 {+-} 1.9 cm; range, 1.3-9.9 cm) were treated with microwave ablation. Results: Thirty-eight sessions were performed for 24 nodules in 15 patients. The follow-up period was 4-31 months (mean, 12.8 {+-} 8.0 months). The ablation success rate, the technique effectiveness rate, and the local tumor progression rate were 91.7% (22/24), 87.5% (21/24), and 25% (6/24) respectively according to the results of follow-up. The cumulative overall 6, 12, 24 month survival rates were 78.8%, 60.0%, and 60.0%, respectively. Major complication occurred including liver abscess in two patients (13.3%) and needle seeding in one patient (6.7%). Both complications were cured satisfied with antibiotic treatment combined to catheter drainage for abscess and resection for needle seeding. The minor complications and side effects were experienced by most patients which subsided with supportive treatment. Conclusion: Microwave ablation can be used as a safe and effective technique to treat intrahepatic primary cholangiocarcinoma.

  12. An economic evaluation of first-trimester genetic sonography for prenatal detection of Down syndrome.

    Science.gov (United States)

    Vintzileos, A M; Ananth, C V; Fisher, A J; Smulian, J C; Day-Salvatore, D; Beazoglou, T

    1998-04-01

    To determine 1) the diagnostic accuracy requirements of first-trimester genetic sonography from the cost-benefit point of view and 2) the economic impact of first-trimester genetic sonography for the United States on the basis of the accuracy of previously published studies. A cost-benefit equation was developed on the basis of the hypothesis that the cost of chorionic villus sampling (CVS) in pregnant women with advanced maternal age (at least 35 years old) should be at least equal to the cost of genetic sonography with CVS used only for those with abnormal ultrasound results. The components of the equation included the diagnostic accuracy of genetic ultrasound (sensitivity and specificity for detecting Down syndrome), the costs of the CVS package and genetic ultrasound, and the lifetime cost of Down syndrome cases. First-trimester genetic sonography was found to be beneficial if the overall sensitivity for detecting Down syndrome was greater than 70%, and even then, the cost-benefit ratio depended on the corresponding false-positive rate. The required minimum ultrasound sensitivity varied according to the maternal age-specific prevalence of Down syndrome and ranged between 40% (for women 35 years old) to 96% (for women 44 years old). Of eight published cohorts using nuchal translucency thickness for genetic sonography, five had accuracies of genetic ultrasound compatible with net benefits. The benefits of first-trimester genetic sonography depend on its diagnostic accuracy. First-trimester genetic sonography has the potential for annual savings of 22 million dollars in the United States.

  13. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  14. Evolutionary Changes of Traumatic lntrahepatic Hematomas at Sonography

    International Nuclear Information System (INIS)

    Kim, Se Hun; Lee, Nam Suk; Lee, Soo Kyung; Cho, Won Soo; Kim, Pyo Nyun; Kim, Il Young

    1995-01-01

    To evaluate the echo pattern of early stage intrahepatic hematoma and change of the echogenicity according to the time lapse. Twenty-four patents with blunt abdominal trauma underwent sonography. Intrahepatic hematomas were sonographic ally, clinically or operatively diagnosed. Sonograms were retrospectively reviewed by the three observers with consensus. We divided the time interval into 4 groups as follows; within 24 hours, 2 to 7 days, 8 to 30 days, and after one month. The echogenicity, shape and location of intrahepatic hematomas were analyzed. Intrapatic hematomas occurred in the right lobe of the liver in 91.6%, especially in the posterior segment. The margin of hematoma was irregular in 23 cases and well-defined in one case. The shape of intrahepatic hematoma was round in 75%. The echogenicity of hematoma was as follows: within24 hours, hyperechoic(6/14), mixed-echoic(6), hypoechoic(2): in 1∼7 days, hyperechoir(1/10), mixed-echoic(6),hypoechoic(3): in 8∼30 days, mixed-echoic(5/14), hypoechoic(9) respectively. Two cases were completely resolved.All 7 cases were hypoechoic on sonogram after 31 days. On available follow-up sonograms the lesion showed decreased echogenicity in 3 of 5 cases at 1∼7 days interval, 7 of 12 cases at 8∼30 days interval, and 5 of 6 cases after 1 month interval. The echogenicity of the early stage of intrahepatic hematoma was mainly hyperechoic or mixed-echoic. The echogenicity of hematoma decreased with time lapse

  15. Transcranial parenhymal sonography in the diagnosis of Parkinson's disease

    Directory of Open Access Journals (Sweden)

    Mijajlović Milija

    2008-01-01

    Full Text Available Bacground/Aim. Modern ultrasound systems allow highresolution transcranial sonography (TCS of the brain structures. Enlargement of the echogenic signal (hyperechogenicity of the substantia nigra (SN has been reported as a highly characteristic finding in idiopathic Parkinson's disease (PD and is thought to reflect increased amounts of iron, bound to proteins other than ferritin, in the SN in the course of neurodegeneration. The aim of our study was to investigate the prevalence of the SN hyperechogenicity in PD patients, as well as its possible clinical correlates. Methods. The study comprised 103 consecutive PD patients and 50 healthy age-matched controls. For TCS examination a color-coded, phased array ultrasound system equipped with a 2.5 MHz transducer was used (ESAOTE Technos MP, Italia. The examination was performed through a preauricular acoustic bone window with a penetration depth of 16 cm and a dynamic range of 45-50 dB. The SN was identified within the butterfly shaped structure of the mesencephalic brainstem, with scanning from both temporal windows. Results. The SN hyperechogenicity was identified in 95 out of 103 examined PD patients (92%, which was marked in 60 (63%, and moderate in 35 patients (37%. Median SN echogenic size was larger contralateral to the clinically more affected side of the body. Unilateral SN hyperechogenicity was also found in 5 out of 50 healthy controls (10%. No ventricular enlargements were notified in our study. Conclusion. Our study demonstrated SN hyperechogenicity in more than 90% of PD patients. In adult subjects without neurological symptoms, the TCS finding of at least unilaterally marked SN hyperechogenicity indicates a subclinical functional impairment of the nigrostriatal dopaminergic system. .

  16. Prognostic Value of Diagnostic Sonography in Patients With Plantar Fasciitis.

    Science.gov (United States)

    Fleischer, Adam E; Albright, Rachel H; Crews, Ryan T; Kelil, Tatiana; Wrobel, James S

    2015-10-01

    The primary objective of this study was to determine whether the sonographic appearance of the plantar fascia is predictive of the treatment (ie, pain) response in patients receiving supportive therapy for proximal plantar fasciitis. This study was a secondary analysis of data obtained from a randomized controlled trial of ambulatory adults, which examined the efficacy of 3 different foot supports for plantar fasciitis. Participants underwent diagnostic sonographic examinations of their heel at baseline and again at 3 months by a single experienced foot and ankle surgeon. Quantitative (eg, thickness) and qualitative (eg, biconvexity) characteristics of the fascia were recorded according to a standard protocol. Logistic regression models were used to identify predictors of the pain response. Seventy patients completed a baseline evaluation, and 63 patients completed a 3-month follow-up assessment. The pain response was not associated with the type of foot support (P> .05). The only significant indicator of an unfavorable response in the univariate and multivariate analyses was biconvexity of the plantar fascia on sonography at presentation (multivariate odds ratio, 4.76 [95% confidence interval, 1.16-19.5; P= .030). Furthermore, changes in self-reported pain over the 3-month study period were not accompanied by alterations in plantar fascia thickness over this time (r = .056; P = .671). We conclude that patients who present with biconvexity of the plantar fascia may be less responsive to tier 1 treatment regimens that center around mechanical support of the plantar fascia. Furthermore, follow-up measurements of the fascia in this population should not weigh heavily in decisions such as return to play. © 2015 by the American Institute of Ultrasound in Medicine.

  17. Sonography of the painful shoulder: role of the operator's experience

    International Nuclear Information System (INIS)

    Corroller, Thomas Le; Cohen, Michel; Champsaur, Pierre; Aswad, Richard; Pauly, Vanessa

    2008-01-01

    The aim of our study was to determine the role of the operator's experience in the sonographic evaluation of the painful shoulder and to validate assumptions about its technical performance in routine practice. Two radiologists, respectively standard and expert sonographic operators, independently and prospectively scanned 65 patients with clinical suspicion of rotator cuff lesion. Magnetic resonance arthrography was the reference standard. The sensitivity of the expert ultrasound operator was 95.3% for full-thickness rotator cuff tears (41/43), 70.6% for partial-thickness tears (12/17), 64.3% for intratendinous tears (9/14), 100% for abnormality of the long head of biceps tendon (seven of seven), 88.9% for supraspinatus tendinosis (16/18), 96.4% for subacromial bursa abnormalities (53/55), and 91.7%for acromioclavicular joint osteoarthritis (33/36). The two sonographic operators were in very good agreement about full-thickness rotator cuff tears (κ=0.90), supraspinatus tendinosis (κ =0.80), abnormalities of the long head of biceps tendon (κ=0.84), subacromial bursa abnormalities (κ=0.89), and acromioclavicular osteoarthritis (κ=0.81). The agreement was only moderate for partial-thickness tears (κ=0.63) and intratendinous tears (κ=0.57). Our results show that in moderately experienced hands as in experts' hands, sonography has a low level of interobserver variability for full-thickness rotator cuff tears. Considering partial-thickness and intratendinous rotator cuff tears, our data suggest that interobserver variability is higher. (orig.)

  18. Transcranial sonography: integration into target volume definition for glioblastoma multiforme

    International Nuclear Information System (INIS)

    Vordermark, Dirk; Becker, Georg; Flentje, Michael; Richter, Susanne; Goerttler-Krauspe, Irene; Koelbl, Oliver

    2000-01-01

    Purpose: Recent studies indicate that transcranial sonography (TCS) reliably displays the extension of malignant brain tumors. The effect of integrating TCS into radiotherapy planning for glioblastoma multiforme (GBM) was investigated herein. Methods and Materials: Thirteen patients subtotally resected for GBM underwent TCS during radiotherapy planning and were conventionally treated (54 to 60 Gy). Gross tumor volumes (GTVs) and stereotactic boost planning target volumes (PTVs, 3-mm margin) were created, based on contrast enhancement on computed tomography (CT) only (PTV CT ) or the combined CT and TCS information (PTV CT+TCS ). Noncoplonar conformal treatment plans for both PTVs were compared. Tumor progression patterns and preoperative magnetic resonance imaging (MRI) were related to both PTVs. Results: A sufficient temporal bone window for TCS was present in 11 of 13 patients. GTVs as defined by TCS were considerably larger than the respective CT volumes: Of the composite GTV CT+TCS (median volume 42 ml), 23%, 13%, and 66% (medians) were covered by the overlap of both methods, CT only and TCS only, respectively. Median sizes of PTV CT and PTV CT+TCS were 34 and 74 ml, respectively. Addition of TCS to CT information led to a median increase of the volume irradiated within the 80% isodose by 32 ml (median factor 1.51). PTV CT+TCS volume was at median 24% of a 'conventional' MRI(T2)-based PTV. Of eight progressions analyzed, three and six occurred inside the 80% isodose of the plans for PTV CT and for PTV CT+TCS , respectively. Conclusion: Addition of TCS tumor volume to the contrast-enhancing CT volume in postoperative radiotherapy planning for GBM increases the treated volume by a median factor of 1.5. Since a high frequency of marginal recurrences is reported from dose-escalation trials of this disease, TCS may complement established methods in PTV definition

  19. Hepatic vein flow pattern in children: assesment with Doppler sonography

    International Nuclear Information System (INIS)

    Ahmetoglu, Ali; Kosucu, Polat; Arikan, Elif; Dinc, Hasan; Resit Guemele, Halit

    2005-01-01

    Background: Aim of this study is to establish normal hepatic vein flow pattern and effect of age, sex, activity and feeding status on the hepatic flow pattern in normal Turkish children less than 15 years of ages and also to compare our values with the previously reported studies. Method: Hepatic vein flow patterns were evaluated in 150 children (83 male, 67 female) without any cardiac, pulmonary and liver disease by using Doppler sonography. Blood flow patterns were compared with age, sex, activity, and feeding status of the children. Results: Only 44% of the children had triphasic flow pattern in all hepatic veins. Monophasic flow pattern was the most common flow pattern in children less then 1 year of age. Triphasic flow pattern increase after 1 year of age. Although most of the children older than 1 year of age had triphasic flow pattern, there is some variation in the flow patterns of the hepatic veins in the same subject. Triphasic hepatic flow pattern is most commonly seen in the left hepatic vein and least commonly seen in the right hepatic vein. There was no significant difference between male and girl, children who were agitated or calm and fasting or not fasting in respect to triphasic flow pattern. Conclusion: Liver stiffening is not only the reason for abnormal hepatic flow pattern and some other physiologic factors may also lead to mono and/or diphasic flow pattern in the children. Absence of triphasic flow pattern must not be accepted as a liver pathology in children especially younger than 1 year of age

  20. Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check?

    International Nuclear Information System (INIS)

    Lanza, Cecilia; Fabrizzi, Giancarlo; Russo, Marco

    2006-01-01

    After the insertion of a central venous catheter, a chest radiograph is usually obtained to ensure correct positioning of the catheter tip. To determine in a paediatric population whether B-mode and colour Doppler sonography after central venous access is useful to evaluate catheter position, thus obviating the need for a postprocedural radiograph. A prospective study of 107 consecutive central venous access procedures placed in a paediatric intensive care unit was performed. At the end of the procedure, B-mode and colour Doppler sonography were used to assess catheter position and check for complications. A postprocedural chest radiograph was obtained in all patients. In 96 patients postprocedural B-mode and colour Doppler sonography showed colour Doppler signals within the vena cava. Among the 11 patients predicted to have a potential complication, there was one pneumothorax and ten malpositions. Chest radiography showed a total of 13 complications - 1 pneumothorax and 12 malpositions. The concordance between colour Doppler sonography and chest radiography was 98.1% in the detection of catheter position; sonography had a sensitivity of 84.6% and a specificity of 100%. The close concordance between B-mode and colour Doppler sonography and chest radiography justifies the more frequent use of sonography to evaluate catheter position because ionizing radiation is eliminated. Chest radiography may then be performed only when there is suspected inappropriate catheter tip position after sonography. (orig.)

  1. Top ten pitfalls to avoid when performing musculoskeletal sonography: What you should know before entering the examination room

    International Nuclear Information System (INIS)

    Arend, Carlos Frederico

    2013-01-01

    Sonography has been used successfully to evaluate a number of musculoskeletal disorders. The method is operator dependent and familiarity with sonographic pitfalls greatly improves diagnostic accuracy and helps to optimize management. In this article, we discuss ten common pitfalls which can become a source of confusion and misdiagnosis in musculoskeletal sonography

  2. Open-access transvaginal sonography in women of reproductive age with abnormal vaginal bleeding: a descriptive study in general practice

    NARCIS (Netherlands)

    de Vries, Corlien J. H.; Wieringa-de Waard, Margreet; Bindels, Patrick J. E.; Ankum, Willem M.

    2011-01-01

    Diagnostic ultrasonography is used by GPs in approximately 10% of patients of reproductive age with abnormal vaginal bleeding. Transvaginal sonography is recommended as a first-line diagnostic instrument for assessing uterine pathology. To assess if findings resulting from open-access sonography

  3. Sonography of the neonatal spine: part 1, Normal anatomy, imaging pitfalls, and variations that may simulate disorders.

    Science.gov (United States)

    Lowe, Lisa H; Johanek, Andrew J; Moore, Charlotte W

    2007-03-01

    Our objective is to discuss neonatal spine sonography with emphasis on imaging pitfalls and normal variants that may simulate disease and to distinguish them from true spinal disorders. Sonography of the neonatal spine is now accepted as a highly sensitive, readily available screening study that can be used to evaluate various anomalies of the lumbar spine in most infants younger than 4 months.

  4. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study.

    Science.gov (United States)

    Zavoreo, Iris; Vučićević, Vanja; Boras; Zadravec, Dijana; Bašić, Vanja; Kes; Ciliga, Dubravka; Gabrić, Dragana

    2017-03-01

    Burning mouth syndrome (BMS) is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. Also, the results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. By use of transcranial sonography of the brain parenchyma, substantia nigra , midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years) and 20 controls with chronic pain in the lumbosacral region (61.5±15). Statistical analysis was performed by use of Student t test with significance set at pburning mouth syndrome might reflect central disturbances within this syndrome. Burning Mouth Syndrome; Transcranial Sonography; substantia nigra; Midbrain Raphe Nuclei; Red Nucleus.

  5. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  6. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    International Nuclear Information System (INIS)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon; Hong, Sung Tae; Lee, Me Jeong

    1999-01-01

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  7. Usefulness of high-resolution sonography in early diagnosis of rabbit clonorchiasis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon; Choi, Don Gil; Chung, Il Gyu; Phyun, Lae Hyun; Pyeun, Yong Seon [Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of); Hong, Sung Tae; Lee, Me Jeong [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1999-09-15

    To determine the role of high-resolution sonography in the early diagnosis of experimentally induced clonorchiasis in rabbits. We performed sonographic examination weekly in 22 lightly-infected rabbits (10 rabbits infected with 10 metacercariae, 6 rabbits infected with 20 metacercariae, and 6 rabbits infected with 40 metacercariae), and 10 heavily-infected rabbits (500 metacercariae). The sonographic criterion of diagnosis with dilatation of the intrahepatic ducts. We sacrificed lightly-infected rabbits and counted numbers of adult worms of clonorchis sinensis 9 weeks after infection. Sonographic abnormalities were found 3 weeks after infection in 2 lightly-infected rabbits and 5 heavily-infected rabbits. On sonography at 9 weeks after infection, we observed dilatation of the intrahepatic ducts in 11 (65%) of 17 lightly-infected rabbits and all of 10 heavily-infected rabbits. High-resolution sonography is very useful in early diagnosis of rabbits clonorchiasis.

  8. Sonography as a new diagnostic procedure for investigating abnormalities of the shoulder

    International Nuclear Information System (INIS)

    Rapf, C.; Furtschegger, A.; Resch, H.; Innsbruck Univ.

    1986-01-01

    Eighty-one sonographic examinations of patients with complaints relating to the shoulder joint have shown that this is the method next in value to radiological examination. So far, lesions of the rotator cuff and of the long head of the biceps could only be demonstrated by invasive procedures such as arthrography or arthroscopy. In these situations, sonography attains a similar accuracy. Diffuse lesions can also be diagnosed correctly, making arthrography and arthroscopy unnecessary. In addition, sonography can demonstrate inflammatory and degenerative changes and incomplete sub-acromial and intermediary tears of the rotator cuff, unlike conventional diagnostic methods. In future, arthrography and arthroscopy will only be necessary as additional diagnostic methods if sonography remains inconclusive. (orig.) [de

  9. Comparison of sonography and venography in the diagnosis of lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Mostbeck, G.H.; Kettenbach, J.; Henk, C.

    1993-01-01

    In recent years, non-invasive sonographic techniques [real-time ultrasound (US), duplex ultrasonography (DU) and color-coded duplex sonography (CCDS)] have increased in importance for the diagnosis of lower extremity deep venous thrombosis. To ascertain the accuracy and limitations of these techniques prospectively, various studies have been performed to compare sonography with venography. This review deals with basic methodologic considerations when two imaging methds are compared and describes the features of deep venous thrombosis seen on US, DU and CCDS. Reports comparing sonography and phlebography for the diagnosis of deep venous thrombosis are presented and discussed. The advantages and limitations of US, DU and CCDS for the diagnosis of iliac, femoral, popliteal and infrapopliteal venous thrombosis are compared with those of venography, and controversial areas are touched on. (orig.) [de

  10. Suspected leaking abdominal aortic aneurysm: use of sonography in the emergency room.

    Science.gov (United States)

    Shuman, W P; Hastrup, W; Kohler, T R; Nyberg, D A; Wang, K Y; Vincent, L M; Mack, L A

    1988-07-01

    To determine the value of sonography in the emergent evaluation of suspected leaking abdominal aortic aneurysms, the authors examined 60 patients in the emergency department using sonography and a protocol involving advance radio notification from the ambulance; arrival of sonographic personnel and equipment in the triage room before patient arrival; and, during other triage activities, rapid sonographic evaluation of the aorta for aneurysm and of the paraaortic region for extraluminal blood. Sonographic findings were correlated with surgical results and clinical outcome. When performed under these circumstances, sonography was accurate in demonstrating presence or absence of aneurysm (98%), but its sensitivity for extraluminal blood was poor (4%). A combination of sonographic confirmation of aneurysm, abdominal pain, and unstable hemodynamic condition resulted in the correct decision to perform emergent surgery in 21 of 22 patients (95%). An abbreviated sonographic examination done in the emergency room can provide accurate, useful information about the presence of aneurysm; this procedure does not significantly delay triage of these patients.

  11. Evaluation of renal allograft rejection by Doppler sonography and MR imaging

    International Nuclear Information System (INIS)

    Steinberg, H.V.; Nelson, R.C.; Murphy, F.B.; Baumgartner, B.R.; Bourke, E.; Delaney, V.B.; Whelchel, J.B.; Bernardino, M.E.

    1986-01-01

    The authors prospectively studies the efficacy of Doppler sonography and MR imaging in evaluating renal allografts, with specific attention to transplant rejection. Based on study findings, we were unable to make a statement with respect to the appearance or accuracy of diagnosing cyclosporin toxicity or acute tubular necrosis by either modality due to concomitant rejection in the few patients so afflicted. Moreover, the ability to predict and diagnose the presence or absence of allograft rejection was not affected by different serum creatinine values. Most important, however, Doppler sonography was shown to be superior to MR imaging in evaluating for allograft rejection, as evidenced by its higher sensitivity (100% vs. 71%), specificity (88% vs. 75%), and accuracy (96% vs. 73%). Thus, because of its low cost and ease of accessibility, Doppler sonography should become the primary modality for renal transplant screening

  12. Muscle lesion comparing of imaging procedures (sonography and MRT) -experimental and clinical study

    International Nuclear Information System (INIS)

    Mellerowicz, H.; Lubasch, A.; Dulce, M.; Wagner, S.; Paul, B.

    1993-01-01

    Muscle injuries in sports are more common now. Diagnosis and follow up of muscle injuries is nowadays achieved by sonography and MRT. In order to assess the two imagine procedures, a direct test for comparison of sonography and MRT was performed in an experimental study: A standardised disconnection of m. triceps surae in rats was either sutured and glued or not treated. Clinical studies were performed in 26 patients suffering from muscle trauma. Sonography was proved to be a reliable procedure especially in follow up control until full weight bearing and should be used first. Negative or doubtfull findings require further investigation by MRT. Especially contrast medium (Gd-DTPA) assisted examinations enables a long term follow up and may even show small (muscle strain) and deep lying injuries. (orig.) [de

  13. Acute testicular torsion in children: the role of sonography in the diagnostic workup.

    Science.gov (United States)

    Gunther, P; Schenk, J P; Wunsch, R; Holland-Cunz, S; Kessler, U; Troger, J; Waag, K L

    2006-11-01

    Acute testicular torsion in children is an emergency and has to be diagnosed urgently. Doppler sonography is increasingly used in imaging the acute scrotum. Nevertheless, in uncertain cases, surgical exploration is required. In this study, we attempted to define the role of Doppler sonography in the diagnostic workup of the acutely painful scrotum. All patients admitted between 1999 and 2005 with acute scrotal pain were included. After clinical assessment, patients were imaged by Doppler sonography with a ''high-end'' instrument. In cases of absent arterial perfusion of the testis in Doppler sonography, surgical exploration was carried out. Patients with unaffected perfusion were followed clinically by ultrasound for up to 2 years. Sixty-one infants and children aged 1 day to 17 years (median: 7.9 years) were included. In 14 cases, sonography demonstrated absent central perfusion, with abnormal parenchymal echogenicity in six. Absence of venous blood flow together with reduction of central arterial perfusion was found in one infant. In these 15 patients, surgical exploration confirmed testicular torsion. Among the other 46 patients, we found four cases with increased testicular perfusion and 27 with increased perfusion of the epididymis. In one infant, a testicular tumour was found sonographically, and orchiectomy confirmed diagnosis of a teratoma. Follow-up examinations of the conservatively treated patients showed good clinical outcome with physiologic central perfusion as well as normal echogenic pattern of both testes. No case of testicular torsion was missed. By means of Doppler sonography, an unequivocal statement regarding testicular perfusion was possible in all cases. The initial Doppler diagnosis was confirmed by operative evaluation and follow-up ultrasound. Testicular torsion can therefore be excluded by correctly performed ultrasound with modern equipment.

  14. Reliability and precision of stress sonography of the ulnar collateral ligament.

    Science.gov (United States)

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  15. Using modern teaching strategies to teach upper abdominal sonography to medical students.

    Science.gov (United States)

    Cheng, Wei-Chun; Lin, Xi-Zhang; Chen, Chiung-Yu

    2013-07-01

    Upper abdominal sonography can help physicians to confirm the diagnosis of various hepatobiliary diseases. Teaching sonography skills to medical students is important because it may enhance their level of knowledge and overall development during their gastroenterology section rotation. Sonographic imaging is abstract and students can be easily confused when scanning the abdominal structures from different sites and directions. We used several modern teaching strategies to facilitate the learning of sonography skills. The year five medical students beginning a gastroenterology section rotation for their first-year clerkship were taught abdominal sonography skills. Abstract sonographic images were related to concrete objects and the surrounding structures were further indicated. Each of the images was given a specific name and was sorted according to the scanning site. A mnemonics system was designed to help students to memorize the names of these images. A badge was created to recognize the achievement of being able to complete a basic upper abdominal sonography. Students were free (i.e., not obligated) to request a demonstration opportunity to show their skills within 2 weeks after receiving tutelage. We recorded the number of students who received training and were able to successfully complete the task; these individuals then received a badge to be pinned onto their white coats. Sixty-three of 68 students (92.6%) requested evaluation and all of them passed. We have greatly simplified the process of learning about upper abdominal sonography by using andragogy to enhance learning, mnemonics to help memory, and a pin-badge reward system to stimulate incentives. Copyright © 2013. Published by Elsevier B.V.

  16. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  17. Radiofrequency ablation assisted by real-time virtual sonography for hepatocellular carcinoma inconspicuous under sonography and high-risk locations

    Directory of Open Access Journals (Sweden)

    Cheng-Han Lee

    2015-08-01

    Full Text Available Radiofrequency ablation (RFA is an effective and real-time targeting modality for small hepatocellular carcinomas (HCCs. However, mistargeting may occur when the target tumor is confused with cirrhotic nodules or because of the poor conspicuity of the index tumor under ultrasonography (US. Real-time virtual sonography (RVS can provide the same reconstruction computed tomography images as US images. The aim of this study is to investigate the usefulness of RVS-assisted RFA for HCCs that are inconspicuous or conspicuous under US. A total of 21 patients with 28 HCC tumors—divided into US inconspicuous and high-risk subgroup (3 tumors in 3 patients, US inconspicuous and nonhigh-risk subgroup (5 tumors in 4 patients, US conspicuous and high-risk subgroup (16 tumors in 14 patients, and US conspicuous and nonhigh-risk subgroup (4 tumors in 3 patients—underwent RVS-assisted RFA between May 2012 and June 2014 in our institution. The mean diameter of the nodules was 2.0 ± 1.1 cm. The results showed that the complete ablation rate is 87.5% (7/8 in the US undetectable group and 75% (15/20 in the US detectable group. A comparison between six tumors with incomplete ablation and 22 tumors with complete ablation showed higher alpha-fetoprotein level (mean, 1912 ng/mL vs. 112 ng/mL and larger tumor size (mean diameter, 26 mm vs. 16 mm in the incomplete ablation nodules (both p < 0.05. In conclusion, RVS-assisted RFA is useful for tumors that are difficult to detect under conventional US and may also be useful for tumors in high-risk locations because it may prevent complication induced by mistargeting.

  18. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F.

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical that of splenic trauma in all cases. The result show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children [fr

  19. Contributions of scintigraphy and sonography to the diagnosis of traumatic splenic lesions in children

    Energy Technology Data Exchange (ETDEWEB)

    Soucy, J.P.; Danais, S.; Filiatrault, D.; Lamoureux, J.; Lamoureux, F. (Hopital Sainte-Justine, Montreal (Canada))

    1984-01-01

    20 children who were sent to the Nuclear Medicine and Sonography services for evaluation of the spleen in the context of a history of abdominal trauma were studied. All but one of the children were treated conservately, the exception having had on emergency renal procedure performed for renal rupture. The working diagnosis, based on the clinical, was that of splenic trauma in all cases. The results show a sensitivity of 90% (2 false negatives) for scintigraphy, and of 30% (14 false negatives) for sonography for the non-invasive diagnosis of splenic trauma in children.

  20. Diagnosis of Pentalogy of Cantrell in the First Trimester Using Transvaginal Sonography and Color Doppler

    Directory of Open Access Journals (Sweden)

    Ayşe Figen Türkçapar

    2015-01-01

    Full Text Available We report the prenatal diagnosis of Cantrell syndrome in the first trimester. During a routine transabdominal ultrasonographic examination, a midline supraumbilical abdominal wall defect including herniated liver and ectopia cordis with a large omphalocele containing the intestines and cystic hygroma was incidentally identified at the 12th week of gestation. A transvaginal sonography examination revealed a severe lumbosacral scoliosis in addition to the inability to visualize the abdominal aorta which was indicative of a severe intracardiac defect. The parents opted for pregnancy to be terminated. In this case report, we discuss the complementary role of transvaginal sonography and Doppler imaging in the diagnosis of Cantrell syndrome in early pregnancy.

  1. [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

    Science.gov (United States)

    Rjosk-Dendorfer, D; Reichelt, A; Clevert, D-A

    2014-03-01

    In recent years the use of elastography in addition to sonography has become a routine clinical tool for the characterization of breast masses. Whereas free hand compression elastography results in qualitative imaging of tissue stiffness due to induced compression, shear wave elastography displays quantitative information of tissue displacement. Recent studies have investigated the use of elastography in addition to sonography and improvement of specificity in differentiating benign from malignant breast masses could be shown. Therefore, additional use of elastography could help to reduce the number of unnecessary biopsies in benign breast lesions especially in category IV lesions of the ultrasound breast imaging reporting data system (US-BI-RADS).

  2. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Layer, G.; Steudel, A.; Schild, H.H.; Schmitteckert, H.; Tuengerthal, S.; Schirren, J.; Kaick, G. van

    1999-01-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [de

  3. Angle-corrected imaging transcranial doppler sonography versus imaging and nonimaging transcranial doppler sonography in children with sickle cell disease.

    Science.gov (United States)

    Krejza, J; Rudzinski, W; Pawlak, M A; Tomaszewski, M; Ichord, R; Kwiatkowski, J; Gor, D; Melhem, E R

    2007-09-01

    Nonimaging transcranial Doppler sonography (TCD) and imaging TCD (TCDI) are used for determination of the risk of stroke in children with sickle cell disease (SCD). The purpose was to compare angle-corrected, uncorrected TCDI, and TCD blood flow velocities in children with SCD. A total of 37 children (mean age, 7.8 +/- 3.0 years) without intracranial arterial narrowing determined with MR angiography, were studied with use of TCD and TCDI at the same session. Depth of insonation and TCDI mean velocities with and without correction for the angle of insonation in the terminal internal carotid artery (ICA) and middle (MCA), anterior (ACA), and posterior (PCA) cerebral arteries were compared with TCD velocities with use of a paired t test. Two arteries were not found on TCDI compared with 15 not found on TCD. Average angle of insonation in the MCA, ACA, ICA, and PCA was 31 degrees , 44 degrees , 25 degrees , and 29 degrees , respectively. TCDI and TCD mean depth of insonation for all arteries did not differ significantly; however, individual differences varied substantially. TCDI velocities were significantly lower than TCD velocities, respectively, for the right and left sides (mean +/- SD): MCA, 106 +/- 22 cm/s and 111 +/- 33 cm/s versus 130 +/- 19 cm/s and 134 +/- 26 cm/s; ICA, 90 +/- 14 cm/s and 98 +/- 27 cm/s versus 117 +/- 18 cm/s and 119 +/- 23 cm/s; ACA, 74 +/- 24 cm/s and 88 +/- 25 cm/s versus 105 +/- 23 cm/s and 105 +/- 31 cm/s; and PCA, 84 +/- 27 cm/s and 82 +/- 21 cm/s versus 95 +/- 23 cm/s and 94 +/- 20 cm/s. TCD and angle-corrected TCDI velocities were not statistically different except for higher angle-corrected TCDI values in the left ACA and right PCA. TCD velocities are significantly higher than TCDI velocities but are not different from the angle-corrected TCDI velocities. TCDI identifies the major intracranial arteries more effectively than TCD.

  4. Prenatal diagnosis of the Dandy-Walker syndrome by sonography and computed tomography

    International Nuclear Information System (INIS)

    Toelly, E.; Ebner, F.; Oberbauer, R.W.

    1984-01-01

    A case of Dandy-Walker-syndrome is presented, comparing the value of sonography and CT in intrauterine diagnosis. Together with a review of the literature of the subject, pathogenesis, morphology and prognosis in regard to the psychomotoric development are discussed. (orig.) [de

  5. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  6. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  7. Women's perception of transvaginal sonography in a tertiary hospital in nigeria

    International Nuclear Information System (INIS)

    Eze, C.U.; Okaro, A.O.; Nwobi, I.C.

    2008-01-01

    Available studies suggest that pregnant women's views on the desirability of routine ultrasound are Influenced by their perceptions of its potential benefits and concern about possible adverse effects. To assess women's views of transvaginal sonography and to determine any correlation between their perception of the procedure and their prior knowledge and experience of it. We surveyed women presenting with various gynecologic problems or complications of the first trimester. Data collection was by self-administered questionnaires using conveniences sampling technique on women attending the clinic over a period of one year. Only women who had transvaginal sonography were included. A total of 250 women were recruited and interviewed. Transvaginal sonography was considered not embarrassing by 76%, acceptable by 86%, not painful by 87.2% and not stressful by 82% of the women. There were no statistically significant differences in the women's perception of the procedure whether they had prior knowledge and previous experience of the procedure or not (P>0.05). The majority of the women perceived transvaginal sonography favourably. Their perception of the Procedure was favourable whether they had prior knowledge and previous experience of it or not. (author)

  8. The accuracy of chest sonography in the diagnosis of small pleural effusion

    International Nuclear Information System (INIS)

    Kocijancic, I.

    2003-01-01

    Background. The aim of the study was to evaluate the accuracy of chest sonography in the radiological diagnosis of small pleural effusions. Patients and methods. Patients referred for abdominal and/or chest sonographies for various reasons were examined for sonographic features of pleural effusion. From January 1997 till January 2000, 69 patients were included into the study. Fifty-two patients were found to have pleural effusion not exceeding 15 mm in depth, the rest of them served as controls. Subsequently erect posteroanterior and expiratory lateral decubitus projections were done in all patients. Results. Compared to radiological examination chest sonography had a positive predictive value of 92% in the diagnosis of small pleural effusions in our study population. The mean thickness of fluid was 9.2 mm on ultrasonography and 7.6 mm on expiratory lateral decubitus views (P<0.01). Conclusions. Chest sonography showed a high degree of accuracy for demonstrating small pleural effusions and could replace lateral decubitus chest radiographs adequately. (author)

  9. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  10. The role of colour Doppler sonography in the diagnosis of lower limb Klippel–Trénaunay syndrome

    International Nuclear Information System (INIS)

    Qi, H.T.; Wang, X.M.; Zhang, X.D.; Zhang, M.H.; Li, C.M.; Bao, S.G.; Yuan, H.

    2013-01-01

    Aim: To investigate the accuracy of colour Doppler sonography as compared to phlebography in patients with Klippel-Trénaunay syndrome (KTS). Materials and methods: From September 2004 to May 2012, 59 consecutive patients seen in Shandong medical imaging research institute with a clinical suggestion of KTS were included. Thirty-four were female and 25 were male, with a mean age of 28.4 years. Colour Doppler sonography was used to assess the lower limb veins. The main sonographic criteria for a positive diagnosis were visualization of the lateral vein or sciatic vein, capillary haemangioma, and abnormality of the deep veins. These data were compared with phlebography findings. The κ statistic was used to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, and accuracy of colour Doppler sonography as a diagnostic test were assessed. Results: Colour Doppler sonography findings were positive in 21 of 59 patients with a clinical suggestion of KTS. The diagnosis was confirmed using phlebography in 22 patients. There were two false-positive results and one false-negative result by colour Doppler sonography. The κ-value was 0.892. Sensitivity, specificity, positive and negative predictive values, and accuracy for colour Doppler sonography were 95.4, 94.6, 91.3, 97.2, and 94.9%, respectively. Conclusion: Colour Doppler sonography is an accurate, reliable, and non-invasive investigation in the assessment of patients with suspected KTS

  11. The role of sonography in patients with breast cancer presenting as an axillary mass

    International Nuclear Information System (INIS)

    Park, Sun Young; Kim, Eun Kyung; Oh, Ki Keun; Lee, Kyong Sik; Park, Byeong Woo

    2002-01-01

    To compare sonography and mammography in terms of their diagnostic value in breast cancer cases which initially presented as an axillary mass without a palpable mass or other clinical symptoms. Seven patients with enlarged axillary lymph nodes who first presented with no evidence of palpable breast lesions and who underwent both mammography and sonography were enrolled in this study. In six of the seven, the presence of metastatic adenocarcinoma was confirmed preoperatively by axillary needle aspiration biopsy; in four, subsequent sonographically guided breast core biopsy performed after careful examination of the primary site indicated that primary breast cancer was present. In each case, the radiologic findings were evaluated by both breast sonography and mammography. Breast lesions were detected mammographically in four of seven cases (57%); in three of the four, the lesion presented as a mass, and in one as microcalcification. In three of these four detected cases, fatty or scattered fibroglandular breast parenchyma was present; in one, the parenchyma was dense. In the three cases in which lesions were not detected, mammography revealed the presence of heterogeneously dense parenchyma. Breast sonography showed that lesions were present in six of seven cases (86%); in the remaining patient, malignant microcalcification was detected at mammography. Final pathologic examination indicated that all breast lesions except one, which was a ductal carcinoma in situ, with microinvasion, were infiltrating ductal carcinomas whose size ranged from microscopic to greater than 3 cm. At the time of this study, all seven patients were alive and well, having been disease free for up to 61 months after surgery. In women with a palpable axillary mass confirmed as metastatic adenocarcinoma, breast sonography may be a valuable adjunct to mammography

  12. Use and effectiveness of scintigraphy, sonography and angiography in circumscribed disease of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Pokieser, H; Czembirek, H; Mayrhofer, H; Urbanek, A; Kahn, P; Weiss, W; Base, W [Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria); Vienna Univ. (Austria). 1. Medizinische Klinik; Hanuschkrankenhaus, Vienna (Austria). 1. Medizinische Abt.)

    1977-02-01

    The effectiveness of scintigraphy, sonography and angiography is compared in a material of 140 cases of circumscribed disease of the liver. Typical clinical starting points are defined as points of reference of the diagnostic techniques. Clinical diagnosis is very safe in cases of secondary blastoma and hepatocellular carcinoma of the liver. Since the great majority of these conditions cause space-occupying lesions of the liver, problems of radiologic diagnosis are confined to the smaller number of clinically ill-defined lesions. For the diagnosis of secondary blastomas and cystic processes of all kinds, scintigraphy and sonography are not improved by angiography. Solid space-occupying lesions of unknown origin, however, can only be recognized with angiography. Histology of both benign and malignant processes will be correct in more than 90% of cases.

  13. Sonography, CT and MR in soft part growths in the head and neck region

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.; Beigel, A.

    1990-01-01

    14 patients with a space-occupying growth in the head and neck region were examined via sonography, CT and MR to explore and demonstrate by means of a prospective comparative study the possibilities offered by these three imaging methods. Stages are best diagnosed by means of sonography; the leading role of this method is undisputed. To clarify sonographically unclear findings and especially in pre-surgery planning, MR offers advantages over CT on account of the high soft-part contrast and multiplanar visualisation. However, it is impossible or very difficult to differentiate abscesses and lymphadenitides from malignant growths with these three methods solely on the basis of image-morphological criteria. (orig.) [de

  14. Clinical application of a modern high-definition head-mounted display in sonography.

    Science.gov (United States)

    Takeshita, Hideki; Kihara, Kazunori; Yoshida, Soichiro; Higuchi, Saori; Ito, Masaya; Nakanishi, Yasukazu; Kijima, Toshiki; Ishioka, Junichiro; Matsuoka, Yoh; Numao, Noboru; Saito, Kazutaka; Fujii, Yasuhisa

    2014-08-01

    Because of the remarkably improved image quality and wearability of modern head-mounted displays, a monitoring system using a head-mounted display rather than a fixed-site monitor for sonographic scanning has the potential to improve the diagnostic performance and lessen the examiner's physical burden during a sonographic examination. In a preclinical setting, 2 head-mounted displays, the HMZ-T2 (Sony Corporation, Tokyo, Japan) and the Wrap1200 (Vuzix Corporation, Rochester, NY), were found to be applicable to sonography. In a clinical setting, the feasibility of the HMZ-T2 was shown by its good image quality and acceptable wearability. This modern device is appropriate for clinical use in sonography. © 2014 by the American Institute of Ultrasound in Medicine.

  15. Duplex sonography and magnetic resonance imaging in the clarification of nephrological complications after renal transplant

    International Nuclear Information System (INIS)

    Gueckel, C.; Krestin, G.P.; Wienand, P.

    1989-01-01

    A prospective study compared Duplex sonography and magnetic resonance imaging in evaluating renal transplant. Hundred and two Duplex sonographic and 24 MR examinations were performed and correlated with clinical course or biopsy. All normal renal allografts, 6 transplants with acute tubular necrosis and 2 cases of cyclosporin toxicity had normal Doppler waveforms, whereas 9 renal transplants with evidence of interstitial rejection by biopsy showed an obliteration or reversal of diastolic flow. MR imaging was less specific in identifying allograft rejection. There were false positive results in normal renal transplants, allografts with acute tubular necrosis and after rejection therapy. With regard to cost, accessibility and specificity, Duplex sonography is the method of choice for the evaluation of renal allografts. (orig.) [de

  16. 10 MHz b-scan sonography of the cervical carotid arteries

    International Nuclear Information System (INIS)

    Kuhn, F.P.; Kraemer, G.; Bauer, R.; Klotter, H.J.; Mainz Univ.; Mainz Univ.

    1984-01-01

    Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed. (orig.) [de

  17. Rectal sonography before and after radiation treatment in inoperable cervical cancer

    International Nuclear Information System (INIS)

    Deutinger, J.; Bernaschek, G.; Tatra, G.

    1989-01-01

    Transrectal sonography is helpful in the classification of parametrial infiltration prior to treatment as well as in the follow-up. In this study, we performed rectal sonography in cases of inoperable cervical cancer to objectify the reduction of the infiltration of the uterine cervix and of the parametrium. Rectosonography was performed in 10 patients with histologically confirmed cancer of the uterine cervix before and after radiation treatment. The patients were treated with brachytherapy and teletherapy with an average radiation dose of 7680 rad. The whole therapy was finished after 6 to 9 weeks. Rectosonography enabled us to objectify the effect of radiation therapy. The length and width of parametrial infiltration could be measured in relation to the pelvis wall. Furthermore, the configuration of the parametrium could be imaged. Therefore, in cervical cancer, rectosonography is a valuable method to check and the documentate the effect of treatment and to diagnose recurrency. (orig.) [de

  18. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  19. Malignant and benign diseases of the breast in 41 male patients: mammography, sonography and pathological correlations; Maligne und benigne Erkrankungen der Brust bei 41 maennlichen Patienten: Mammographie und Sonographie mit histopathologischer Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Partik, B.; Mallek, R.; Pokieser, P.; Wunderbaldinger, P.; Helbich, T.H. [Vienna Univ. (Austria). Klinik fuer Radiodiagnostik; Rudas, M. [Vienna Univ. (Austria). Inst. fuer Klinische Pathologie

    2001-11-01

    Aim: The goal of our study was to evaluate findings in mammography and sonography in male patients with pathohistologically proven diseases of the breast. Material and Methods: Mammographies and sonographies, which were obtained in 41 male patients in a 6-year period, were retrospectively evaluated in accordance with the BI-RADS trademark classification. Results: Histologically 13 carcinomas, 21 gynecomastias, 3 pseudogynecomastias, 2 epithelial inclusion cysts and 2 other benign lesions were diagnosed. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of mammography in differentiation of benign versus malignant disease were 92%, 89%, 80%, 96% and 90%, respectively. Additional sonography did not change these results. However, sonography increased diagnostic confidence in 18.2% (2/11) of suspicious lesions. Conclusion: In our study the invasive ductal carcinoma of male patients was a predominantly lobulated, ill-defined lesion in mammography and sonography. The differentiation of carcinoma to pseudogynecomastia and diffuse or dendritic gynecomastia was securely feasible. However, we could not reliably distinguish between carcinoma and some benign mass lesions. In cases of mammographically diagnosed masses or unclear mammography, additional sonography should be performed to increase the diagnostic confidence. (orig.) [German] Ziel: Die Befunde von Mammographie und Sonographie bei histologisch gesicherten malignen und benignen Mammaerkrankungen maennlicher Patienten zu evaluieren. Material und Methode: Retrospektiv wurden die in einem Zeitraum von 6 Jahren durchgefuehrten Mammographien und Sonographien bei 41 maennlichen Patienten in Anlehnung an die BI-RADS trademark Klassifikation ausgewertet. Resultate: Es wurden 13 Karzinome, 21 Gynaekomastien, 3 Pseudogynaekomastien, 2 Atherome und 2 weitere benigne Laesionen histologisch diagnostiziert. Die Mammographie zeigte in der Differenzierung maligne versus benigne Laesion

  20. X-ray or sonography - at the example of the mesotheliomen

    International Nuclear Information System (INIS)

    Wimmer, B.; Grosser, G.; Kaiser, D.

    1981-01-01

    The primary method to present the mesothelioma is always the X-ray picture. The differential-diagnostical spectrum, however, is very wide. Sonography and computerized tomography can help to see the regions around the mesothelioma better. Thus, a large number of differential-diagnostical possibilities can be excluded. None of these methods, however, is able to substitute a histological definition. This is only possible by using effusion cytology, closed or open biopsy. (MG) [de

  1. [Performances and place of sonography in the diagnostic of endometriosis: CNGOF-HAS Endometriosis Guidelines].

    Science.gov (United States)

    Philip, C-A; Dubernard, G

    2018-03-01

    Endometriosis is difficult to diagnose clinically. Transvaginal sonography (TVS) is a procedure that is known to be operator-dependent, which mean that published evidences has to be balanced with the level of the sonographer that produced the data. The objective of this publication was to assess the performances of the sonography in the diagnosis of endometriosis in order to establish the French national recommendations. We searched the MEDLINE database for publication from January 2000 to September 2017 using keywords associated with endometriosis and sonography. Eighty-four trial and reviews published in English or French were included. Ovarian endometrioma can usually be diagnosed by a non-expert sonographer, especially when its aspect is typical. In case of an ovarian cyst with atypical presentation, it is recommended to control the sonography by a referent or to perform an MRI. In menopaused women, any ovarian cyst should be considered as a cancer until proven otherwise. In the diagnosis of posterior deep invasive endometriosis (DIE), TVS with sensitivity and specificity of 96 and 99% respectively, seems at least equivalent if not superior to MRI. However, these performances are related to expert sonographers. To reach sufficient efficiency in posterior DIE, the estimated learning curve for a sonographer is 44 cases. When posterior DIE is suspected, we recommend proposing a TVS "performed by an expert" or a MRI "at least interpreted by an expert". In anterior DIE, TVS has a good specificity (100%), but its sensitivity is poor in the literature (64%). TVS is therefore not able to eliminate the diagnosis. However a renal ultrasound should be proposed each time a urinary endometriosis is confirmed, and should be considered whenever posterior DIE is diagnosed especially the lesion is superior to 3cm. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Mammary blood supply in various diseases as evidenced by color Doppler sonography

    International Nuclear Information System (INIS)

    Kharchenko, V.P.; Rozhkova, N.I.; Zubovskij, G.A.; Medvedeva, N.A.

    1993-01-01

    Color dopplerosonography, traditional sonography, and mammography without contrast staining, as well as physical and pathomorphologic methods were used in examinations of the mammary glands of 76 women aged 18 to 65. Characteristic features of the blood supply to the gland were detected, and differential diagnostic criteria defined on the basis of these findings, to simplify differentiation between malignant and benign nodular formations and the diffuse changes in the mamma

  3. Magnetic resonance tomography and ultrasound in rheumatology; MRT und Sonographie in der Rheumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Ludwig-Boltzmann-Inst. fuer Physikalische und Radiologische Tumordiagnostik, Wien (Austria); Lack, W. [Universitaetsklinik fuer Orthopaedie, Wien (Austria); Machold, K. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie; Graninger, W. [Universitaetsklinik fuer Innere Medizin III, Wien (Austria). Abt. fuer Rheumatologie

    1996-08-01

    Technical innovations and software improvements in magnetic resonance imaging (MRI) and high-resolution sonography (US) have definitely influenced the diagnostic imaging of rheumatic diseases. For MRI, improvements in surface coils, dedicated low-field systems (0.2 T), and software improvements (shorter acquisition times and refinements of fat suppressing techniques) must be mentioned. For sonography, the main innovations concern the development of higher transducer frequencies (7-15 Mhz) and power Doppler imaging. Clinical evaluations have shown that MRI and US are most useful in cases of suspected rheumatic disease with negative plain film radiographs and for documenting the course of the disease, diagnosing of early rheumatoid arthritis, making a differential diagnosis in clinically unclear rheumatic diseases, investigating vascularization, and quantifying pannus formation. In order to improve diagnostic efficacy the role of MRI and US in the management of patients with rheumatic disease should be reconsidered. (orig.) [Deutsch] Technische Innovationen in Hard- und Software von Magnetresonanztomographie (MRT) und Sonographiegeraeten haben die bildgebende Diagnostik in der Rheumatologie massgeblich beeinflusst (Verbesserungen der Oberflaechenspulen mit hohen Gradientenfeldern, dedizierte Niederfeldgeraete, Softwareverbesserungen in Form von kuerzeren Aquisitionszeiten und Verfeinerungen in der Fettunterdrueckung, hoehere Transducerfrequenzen zwischen 7 und 15 Mhz, Powerdopplerverfahren). Fuer die klinische Anwendung bedeutet dies, dass MRT und Sonographie als bildgebende Zusatzverfahren nach der Anfertigung konventioneller Roentgenaufnahmen anzuwenden sind, wenn diese unauffaellige Resultate ergeben oder spezielle Fragen zur Schwere des Krankheitsprozesses bzw. von Folgeerscheinungen zu beantworten sind. Im besonderen betrifft dies den Nachweis der Frueharthritis, die Differentialdiagnose klinisch nicht klar einzuordnender Krankheitsbilder und die Bestimmung des

  4. Prenatal sonography and computed tomography for cerebral malformations of the foetus

    Energy Technology Data Exchange (ETDEWEB)

    Brinkmann, G.; Brix, F.; Weisner, D.

    1987-07-01

    In three pregnant women, sonography and amniocentesis suggested cranial abnormalities of the foetuses. In view of the far-reaching consequences of such a diagnosis, CT was carried out to confirm the diagnosis. It was possible to show the intra-uterine abnormalities and the type of malformation in considerable detail. In one case an encephalocele was demonstrated, in the two others, an anencephalic foetus was shown.

  5. The masked educator-innovative simulation in an Australian undergraduate Medical Sonography and Medical Imaging program.

    Science.gov (United States)

    Reid-Searl, Kerry; Bowman, Anita; McAllister, Margaret; Cowling, Cynthia; Spuur, Kelly

    2014-12-01

    Clinical learning experiences for sonography and medical imaging students can sometimes involve the practice of technical procedures with less of a focus on developing communication skills with patients. Whilst patient-based simulation scenarios have been widely reported in other health education programmes, there is a paucity of research in sonography and medical imaging. The aim of this study was to explore the effectiveness of Mask-Ed™ (KRS Simulation) in the learning and teaching of clinical communication skills to undergraduate medical sonography and medical imaging students. Mask-Ed™ (KRS Simulation) is a simulation technique where the educator is hidden behind wearable realistic silicone body props including masks. Focus group interviews were conducted with 11 undergraduate medical sonography and medical imaging students at CQUniversity, Australia. The number of participants was limited to the size of the cohort of students enrolled in the course. Prior to these interviews participants were engaged in learning activities that featured the use of the Mask-Ed™ (KRS Simulation) method. Thematic analysis was employed to explore how the introduction of Mask-Ed™ (KRS Simulation) contributed to students' learning in relation to clinical communication skills. Key themes included: benefits of interacting with someone real rather than another student, learning made fun, awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection. Mask-Ed™ (KRS Simulation) combined with interactive sessions with an expert facilitator, contributed positively to students' learning in relation to clinical communication skills. Participants believed that interacting with someone real, as in the Mask-Ed characters was beneficial. In addition to the learning being described as fun, participants gained an awareness of empathy, therapeutic communication skills, engaged problem solving and purposeful reflection.

  6. Prenatal sonography and computed tomography for cerebral malformations of the foetus

    International Nuclear Information System (INIS)

    Brinkmann, G.; Brix, F.; Weisner, D.; Kiel Univ.

    1987-01-01

    In three pregnant women, sonography and amniocentesis suggested cranial abnormalities of the foetuses. In view of the far-reaching consequences of such a diagnosis, CT was carried out to confirm the diagnosis. It was possible to show the intra-uterine abnormalities and the type of malformation in considerable detail. In one case an encephalocele was demonstrated, in the two others, an anencephalic foetus was shown. (orig.) [de

  7. Preoperative assessment of intestinal endometriosis: A comparison of transvaginal sonography with water-contrast in the rectum, transrectal sonography, and barium enema.

    Science.gov (United States)

    Bergamini, Valentino; Ghezzi, Fabio; Scarperi, Stefano; Raffaelli, Ricciarda; Cromi, Antonella; Franchi, Massimo

    2010-12-01

    To evaluate the accuracy of Transrectal Sonography (TRS) and a new technique, Transvaginal Sonography with Water-Contrast in the Rectum (RWC-TVS), in the diagnosis of rectosigmoid endometriosis, and the accuracy of Barium Enema (BE) and RWC-TVS in the detection of intestinal stenosis due to endometriosis. In a prospective study, we compared the findings of TRS and RWC-TVS performed before surgery with the operative and pathologic findings in 61 consecutive patients who underwent laparoscopy or laparotomy for suspected rectosigmoid endometriosis. The accuracy of BE and RWC-TVS in the detection of intestinal stenosis was evaluated comparing the radiologic and ultrasonographic results with the macroscopic findings at surgery and pathology. RWC-TVS diagnosed rectosigmoid endometriosis with the same accuracy of TRS and was equally efficient as BE in the detection of a significant intestinal lumen stenosis. For the diagnosis of rectosigmoid endometriosis the sensitivity, specificity, positive and negative predictive values of TRS and RWC-TVS were 88.2% and 96%, 80%, and 90%, 95.7%, and 98%, and 57.1% and 81.8%, respectively. For the detection of intestinal stenosis the sensitivity, specificity, positive and negative predictive values of BE and RWC-TVS were 93.7% and 87.5%, 94.2% and 91.4%, 88.2% and 82.3%, and 97% and 94.1%, respectively. RWC-TVS is a new, simple technique for a single-step and accurate preoperative assessment of rectosigmoid endometriosis.

  8. Comparison of computerized tomography to sonography, applied in diseases of the pancreas

    International Nuclear Information System (INIS)

    Kluge, K.

    1982-01-01

    The examination results of 418 patients whose epigastria had been examined both by computerized tomography and sonography over 1 week in the time from beginning January 1978 until and of July 1979 were compared with regard to the imaging of the pancreas, reliability, and the specificity and sensitivity in establishing the diagnosis. For the sonographic examination, a compound and a real-time unit were used; the computerized tomography was carried out by means of an equipment of the 3rd generation with a scan time of 4 sec. The screening of the pancreas was significantly better using computerized tomography (99.3% US. 84% with US). As for accuracy, computerized tomography had 92.5% exact diagnoses versus 79.9% obtained by sonography. If, however, we look at the cases in which the pancreas could be screened with both methods the accuracy was almost the same (93.7 CT and 93.3% US). Specificity was almost of the same quality, however, the method of computerized tomography with 0.963 was slightly better than ultrasound with 0.943. As for sensitivity, sonography with 0.838 was better than CT with 0.721. The reason for that is the fact that a big part of the chronic pancreatites (30.3%) were not recognized by means of computerized tomography. (orig.) [de

  9. The Significance of Brain Transcranial Sonography in Burning Mouth Syndrome: a Pilot Study

    Directory of Open Access Journals (Sweden)

    Iris Zavoreo

    2017-01-01

    Full Text Available Objective: Burning mouth syndrome (BMS is a chronic disorder which is affecting mostly postmenopausal women and is characterized by burning symptoms in the oral cavity on the clinically healthy oral mucosa. The results of previous studies suggested a possible role of peripheral and/or central neurological disturbances in these patients. The aim of this study was to analyze patients with burning mouth syndrome using transcranial sonography. Methods: By use of transcranial sonography of the brain parenchyma, substantia nigra, midbrain raphe and brain nucleus were evaluated in 20 patients with BMS (64.7±12.3 years and 20 controls with chronic pain in the lumbosacral region (61.5±15. Statistical analysis was performed by use of Student t test with significance set at p<0.05. Results: The results of this study have shown hypoechogenicity of the substantia nigra and midbrain raphe as well as hyperechogenicity of the brain nucleus in BMS patients (p<0,05 as compared to controls. Conclusions: Altered transcranial sonography findings of the brain parenchyma, midbrain raphe and brain nucleus in patients with burning mouth syndrome might reflect central disturbances within this syndrome.

  10. Dedicated training program for shoulder sonography: the results of a quality program reverberate with everyone.

    Science.gov (United States)

    Delzell, Patricia B; Boyle, Alex; Schneider, Erika

    2015-06-01

    The purpose of this study was to define and report on the effect of a comprehensive musculoskeletal sonography training program to improve accuracy (sensitivity and specificity) for the diagnosis of rotator cuff tears in relatively inexperienced operators. Before the training program was implemented, radiologists (n = 12) had a mean of 2 years (range, training shoulder sonographic results were compared to surgical reports or, in their absence, to shoulder magnetic resonance imaging or computed tomographic arthrographic results if within 2 months of the sonographic examination. A total of 82 patients were included in the pre-training group (January 2010-December 2011), and 50 patients were included in the post-training group (January 2012-June 2013). The accuracy, sensitivity, specificity, and positive and negative predictive values were determined for the presence or absence of supraspinatus and infraspinatus tendon tears. After implementation of the training program, the sensitivity of sonography for detecting full-thickness rotator cuff tears increased by 14%, and the sensitivity for detecting partial-thickness rotator cuff tears increased by 3%. Quality improvement programs and acquisition standardization along with ongoing, focused case conferences for the entire care team increased the sensitivity of shoulder sonography for diagnosing both full- and partial-thickness rotator cuff tears, independent of the years of operator experience. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Phylloedes tumor of breast: findings at mammography, sonography and color Doppler imaging

    International Nuclear Information System (INIS)

    Park, Kun Choon; Ahn, Sei Hyun; Kim, Young Hwan; Choi, Hye Yong; Baek, Seung Yon; Yoon, Jeong Hyun

    1994-01-01

    The phylloides tumor of the breast is rare. the purposes of this study were to find the characteristic findings at mammography, sonography, and color Doppler imaging and to evaluate the usefulness of color Doppler study as an additional modality in the diagnosis of phylloides tumor and differentiation between benign and malignant varieties. Eight cases, who were pathologically proven as pylloides tumors, were retrospectively studied. The findings at histologic examination suggested benign in five, malignantin two, and borderline in one. We analyzed the mammograms of all eight patients and sonogram and color Doppler images of four patients. Phylloides tumors were seen as dense masses with lobulated margins in mammograms. On sonography, they showed relatively well-defined masses with in homogenous internal echo pattern and central echogenic areas. They were characterized by the presence of arterial and venous flows in the center and periphery of the lesion on color Doppler imaging and spectral analysis. We conclude that mammographic, sonographic and even color Doppler findings are not predictive of benign or malignant nature of the phylloides tumor. However, mammography and sonography with color Doppler interrogation are helpful in the diagnosis of phylloides tumor

  12. Plantar fascia softening in plantar fasciitis with normal B-mode sonography.

    Science.gov (United States)

    Wu, Chueh-Hung; Chen, Wen-Shiang; Wang, Tyng-Guey

    2015-11-01

    To investigate plantar fascia elasticity in patients with typical clinical manifestations of plantar fasciitis but normal plantar fascia morphology on B-mode sonography. Twenty patients with plantar fasciitis (10 unilateral and 10 bilateral) and 30 healthy volunteers, all with normal plantar fascia morphology on B-mode sonography, were included in the study. Plantar fascia elasticity was evaluated by sonoelastographic examination. All sonoelastograms were quantitatively analyzed, and less red pixel intensity was representative of softer tissue. Pixel intensity was compared among unilateral plantar fasciitis patients, bilateral plantar fasciitis patients, and healthy volunteers by one-way ANOVA. A post hoc Scheffé's test was used to identify where the differences occurred. Compared to healthy participants (red pixel intensity: 146.9 ± 9.1), there was significantly less red pixel intensity in the asymptomatic sides of unilateral plantar fasciitis (140.4 ± 7.3, p = 0.01), symptomatic sides of unilateral plantar fasciitis (127.1 ± 7.4, p plantar fasciitis (129.4 ± 7.5, p plantar fascia thickness or green or blue pixel intensity among these groups. Sonoelastography revealed that the plantar fascia is softer in patients with typical clinical manifestations of plantar fasciitis, even if they exhibit no abnormalities on B-mode sonography.

  13. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  14. Correlation between sonography and antibody activity in patients with Hashimoto thyroiditis.

    Science.gov (United States)

    Willms, Arnulf; Bieler, Dan; Wieler, Helmut; Willms, Diana; Kaiser, Klaus P; Schwab, Robert

    2013-11-01

    Patients with Hashimoto thyroiditis show structural changes of the thyroid that can be identified by a variety of sonographic criteria. We conducted this study to investigate whether there is a correlation between sonography and antibody activity and to assess the role of sonography in the diagnosis and follow-up of Hashimoto thyroiditis. In addition, we present a new classification system (termed the VESINC system [volume, echogenicity, sonographic texture, pseudonodular hypoechoic infiltration, nodules, and cysts]), which helps improve the clarity of sonographic findings. The study included 223 consecutive patients with previously diagnosed Hashimoto autoimmune thyroiditis who attended the thyroid clinic of the German Armed Forces Central Hospital in Koblenz for follow-up examinations between 2006 and 2008. Laboratory tests were performed to measure the levels of free triiodothyronine, free thyroxine, thyrotropin, anti-thyroglobulin antibodies (TgAbs), and antithyroid peroxidase antibodies (TPOAbs). Sonography was performed according to a strict protocol. We then assessed whether a correlation existed between antibody activity and the 6 sonographic variables of the VESINC system. Hypoechogenicity, heterogeneity, and pseudonodular hypoechoic infiltration were associated with significantly higher TPOAb activity (P Hashimoto thyroiditis.

  15. The usefulness of contrast-enhanced sonography in the differential diagnostic of adrenal tumors

    International Nuclear Information System (INIS)

    Slonina, J.; Nienartowicz, E.; Malczewska, J.; Moron, K.; Kumar Agrawal, A.

    2006-01-01

    Introduction: The occurrence of gland tumors causes significant clinical problem. Non hormone-secreting tumors provide the most complicated diagnostic difficulties. The application of contrast-enhanced sonography could improve the vessels visualization and point out characteristic features of benign and malignant changes. The authors believe that this new method make possible the differential adrenal tumor diagnostic process more precise and increase the specificity of ultrasonography in the recognition of benign and malignant tumors. The aim of this study was to define the usefulness of contrasting agent Levovist in differential diagnostics of adrenal tumors and its influence on sensitivity and specificity of ultrasound examination and to establish patients qualification criteria for surgical procedures. Material and methods: Ultrasound examinations were made with the use of digital devise by GE Voluson 740, probe 4.6 MHz with Doppler options and volumetric probe 3D according to the following protocol: 26 patients with recognized adrenal tumor were qualified for the examination. Patients in the first stage of tumor vascularisation had Doppler examination with color (CD) and power Doppler (PD). Three-dimensional ultrasonography was used to improve visualization of vascularisation. In the final phase of the examination the patients were administrated of Levovist in the recommended by the producer dose: 2,5 g in the concentration of 400 mg/l. Results: 26 cases of adrenal gland tumours were subjected to analysis. In standard ultrasonographic examination focal changes in 25 patients were hipoechogenic focuses and in one case the focus was hyperechogenic. Heterogeneity of focuses was observed in 16 cases. In Doppler examination with color (CD) and power Doppler (PD) vascular blood flow was revealed within 12. After using contrasting agent Levovist vascular blood flow was achieved in 4 additional cases, which constituted 61% . Conclusions: 1. 3D ultrasound could be

  16. Prenatal Diagnosis of Persistent Right Umbilical Vein Using Three-dimensional Sonography with Power Doppler

    Directory of Open Access Journals (Sweden)

    Pei-Yin Yang

    2007-03-01

    Conclusion: PRUV is a common vascular anomaly that is easy to be overlooked. Reconstruction of the portal system in the affected fetuses using 3D ultrasound facilitated the identification of the DV. If the DV is present, and other anomalies are excluded, the fetus with PRUV has a good outcome.

  17. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  18. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  19. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    International Nuclear Information System (INIS)

    Poletti, Pierre-Alexandre; Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-01-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT

  20. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  1. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    International Nuclear Information System (INIS)

    Woo, Jeong Joo; Jung, Myung Ja; Kim, Eun Ryung

    2005-01-01

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment

  2. Clinical significance of neonatal parafrontal horn cysts detected by cranial sonography

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jeong Joo [Eulji University of Medicine, Daejeon (Korea, Republic of); Jung, Myung Ja [Sanggye Paik Hospital, Inje University of Medicine, Seoul (Korea, Republic of); Kim, Eun Ryung [Sungae General Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The describe the significance, incidence and characteristics of sonographic findings and long term outcomes of parafrontal horn cysts detected by screening cranial sonography done within the first week following birth. 2122 first cranial ultrasound scans performed over a five year period were retrospectively evaluated and 23 neonates with parafrontal horn cysts were found (which are different from secondary cystic lesions). 17 cases had a birth weight of < 2400 gm with gestation between 30 and 35 weeks, 6 cases had a birth weight of > 2400 gm with gestation between 34 and 41 weeks. The size, shape and location of the parafrontal horn cysts and other associated abnormalities shown on the cranial sonogram were evaluated and sequential ultrasound study, maternal records, neonatal events and neurodevelopmental evaluations were retrospectively assessed. Of the 23 subjects, 21 had isolated parafrontal horn cysts and 2 had subependymal hemorrhages. There was no record of any abnormal perinatal history. The cysts were bilateral in 20 neonates and unilateral in the others. The size of the cysts ranged from 3 to 18 mm in diameter (mean 9 mm). Sonographic features of the parafrontal horn cysts were distinctive morphology (elliptical, thin walled) and location (adjacent to the tip of the frontal horn). In 17 of the cases a follow-up cranial sonography was performed, and all parafrontal horn cysts disappeared within 3 to 6 months. Neurodevelopmental outcomes were normal in those 17 cases. Screening cranial sonography of neonates discovers isolated parafrontal horn cyst. The incidence of parafrontal horn cysts in neonates in our study was 1.1%. They are present in the first week following birth and resolve themselves without medical treatment within a few months. In addition, they show normal neurodevelopment. The parafrontal cysts are suspected to be a benign variant of normal neurodevelopment.

  3. Differentiation of widely invasive and minimally invasive follicular thyroid carcinoma with sonography

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young; Oh, Young Lyun; Kim, Jung Han

    2010-01-01

    Purpose: We evaluated the sonographic findings that can help differentiate widely invasive follicular thyroid carcinomas (WIFTC) from minimally invasive follicular thyroid carcinomas (MIFTC). Methods: We retrospectively compared the sonographic and clinical findings of 24 patients (M:F = 5:19) with 24 MIFTCs and 12 patients (M:F = 1:11) with 13 WIFTCs that were confirmed pathologically and available in sonography at our institution between 1995 and 2007. Results: WIFTC was more common in elderly patients than MIFTC (p < 0.0001). WIFTC was seen with a larger size than MIFTC (p = 0.0092). The best cut-off values for age and size were 49 years and 5.6 cm, respectively. On sonography, all tumors were seen as a well-defined oval or round mass. Heterogeneous mulberry-like echotexture was more common for WIFTC than for MIFTC (77% vs. 25%) (p = 0.0046). The presence of calcifications was more frequent in WIFTC than in MIFTC (54% vs. 8%) (p = 0.0041). Ring calcifications (86%) were the most common type for WIFTC. WIFTC was commonly hypoechoic (70%) and rarely cystic change (8%), but without statistical differences. When WIFTCs represented tumors with two or more findings with a statistical difference, the specificity was 96%. Conclusion: WIFTC is distinguishable from MIFTC by sonography for patients with an age ≥49 years, a tumor ≥5.6 cm, a heterogeneous mulberry-like echotexure, or the presence of calcifications. The sonographic impression of a WIFTC can support a preoperative or intraoperative diagnosis of a difficult case as determined by FNA or with a frozen section.

  4. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    International Nuclear Information System (INIS)

    Reissig, Angelika; Heyne, Jens-Peter; Kroegel, Claus

    2004-01-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli

  5. Reframing conceptual physics: Improving relevance to elementary education and sonography majors

    Science.gov (United States)

    LaFazia, David Gregory

    This study outlines the steps taken to reframe the Waves and Periodicity unit within a conceptual physics course. Beyond this unit reframing process, this paper explores the activities that made up the reframed unit and how each was developed and revised. The unit was reframed to improve relevance of the activities to the Elementary Education and Diagnostic Medical Sonography majors who make up the bulk of the course roster. The unit was reframed around ten design principles that were built on best practices from the literature, survey responses, and focused interviews. These principles support the selection of a biology-integrated themed approach to teaching physics. This is done through active and highly kinesthetic learning across three realms of human experience: physical, social, and cognitive. The unit materials were designed around making connections to students' future careers while requiring students to take progressively more responsibility in activities and assessments. Several support strategies are employed across these activities and assessments, including an energy-first, guided-inquiry approach to concept scaffolding and accommodations for diverse learners. Survey responses were solicited from physics instructors experienced with this population, Elementary Education and Sonography program advisors, and curriculum design, learning strategies, and educational technology experts. The reframed unit was reviewed by doctoral-level science education experts and revised to further improve the depth and transparency with which the design principles reframe the unit activities. The reframed unit contains a full unit plan, lesson plans, and full unit materials. These include classroom and online activities, assessments, and templates for future unit and lesson planning. Additional supplemental materials are provided to support Elementary Education and Sonography students and program advisors and also further promote the reframed unit materials and design

  6. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    Energy Technology Data Exchange (ETDEWEB)

    Reissig, Angelika E-mail: angelika.reissig@med.uni-jena.de; Heyne, Jens-Peter; Kroegel, Claus

    2004-03-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli.

  7. Is sonography performed by the rheumatologist as useful as arthrography executed by the radiologist for the assessment of full thickness rotator cuff tears?

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Neve, W. C.; Bal, D.; Bijlsma, J. W.

    1998-01-01

    Sonography and arthrography are techniques used to detect rotator cuff tears (RCT). The diagnostic value of sonography executed by a rheumatologist versus that of arthrography performed by a radiologist for assessment of RCT was investigated among patients with unilateral chronic shoulder complaints

  8. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  9. Advances in the early diagnosis of congenital hip dysplasia by real-time sonography

    Energy Technology Data Exchange (ETDEWEB)

    Brockmann, W.P.; Wilmsdorf, H.v.; Weh, L.; Korn, U.

    1984-05-01

    Twenty-four infants and children aged five days to three years had their hips examined by ultrasound, and in 17 the findings were compared with the radiographic appearances. Real-time sonography, because of its flexibility, is a suitable screening method for the early diagnosis of hip dysplasia. It has the typical characteristics of a screening method: so far there have been no false negative findings. False positive results are rare, but cannot be completely excluded. The patients examined so far were mostly abnormal, and a final assessment of false positive findings will have to await larger clinical material, including normals. 6 figs.

  10. Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography

    International Nuclear Information System (INIS)

    Yoon, Seok Hwan; Lee, Won Hong; Lee, Dae Hyung

    2009-01-01

    Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of

  11. Diagnosis of Cervical Abortion by TransvaginaI Color Doppler Sonography : A Case Report

    International Nuclear Information System (INIS)

    Lee, Eun Ju; Ryu, Hee Sug; Ji, Hoon; Suh, Jung Ho

    1995-01-01

    Cervical abortion is a spontaneous abortion of an intrauterine pregnancy into the cervical canal where the abortus is retained by a closed external os, causing distension of the cervical canal. Cervical abortion should be distinguished from the cervical pregnancy. We present a case of cervical abortion diagnosed preoperatively by transvaginal sonography and color doppler imaging, and treated by dilatation and curettage. Charateristic transvaginal sonographic findings and identification of subtrophoblastic blood flow by color doppler imaging could allow differentiation of the cevical aborition from the cervical pregnancy

  12. Sonography and CT findings in perigraft reactions after surgical implantation of vascular prostheses

    International Nuclear Information System (INIS)

    Scherer, G.; Roeren, T.; Paetz, B.; Hupp, T.; Kauffmann, G.W.

    1995-01-01

    Between January 1988 and January 1994, 24 patients with heterologeous vascular bypasses were examined with suspected diagnosis of a perigraft reaction (PGR). All patients were subjected to ultrasound and CT. PGR ist defined as a sterile inflammation along the course of a vascular prosthesis. The typical clinical presentation is a fluctuating tumour with a localised painless swelling. In all cases liquid formations could be confirmed by diagnostic imaging procedures; signs of infection could be excluded. The synopsis of the clinical presentation, the time interval after implantation of the prosthetic material and the signs of sonography and CT can reliably exclude infection of the prosthesis and confirm the diagnosis of a PGR. (orig.) [de

  13. Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study.

    Science.gov (United States)

    Saengsin, Jirawat; Vaseenon, Tanawat; Pattamapaspong, Nuttaya; Kritsaneephaiboon, Apipop

    2017-08-01

    A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation >0.7) and after reduction (Pearson Correlation >0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland

  14. Budd-chiari syndrome by membranous obstruction of inferior vena cava: comparison of sonography and computed tomography

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae; Yoon, Yup; Lim, Joo Won

    1992-01-01

    Membranous obstruction of the hepatic inferior vena cava (MOVC) is one of the common causes of Budd-Chiari syndrome. The aim of this study is to ascertain and compare the characteristic sonographic and CT findings of Budd-Chiari syndrome caused by MOVC. We studied 10 patients of Budd-Chiari syndrome caused by MOVC thorough sonography and CT. MOVC was confirmed by operation and/or inferior vena cavography. The cases included 9 men and one woman. With sonography, IVC obstruction was diagnosed in 9 cases. The cause of IVC obstruction was web in 5 cases and fibrous cord in 3 cases. The cause was unspecified in one case. Obliteration of the hepatic veins and intrahepatic collateral vessels were delineated in 9 cases. With color doppler sonography, the directions of blood flow of the hepatic veins through the intervenous communication were fairly well demonstrated in all 5 cases. With CT, IVC obstruction was diagnosed in 7 cases. The obliteration of the hepatic segment of the IVC were segmental in 6 cases and diffuse in one case. CT demonstrated communicating vessels between the hepatic veins in 3 cases. Furthermore, systemic collateral vessels (azygos and hemiazygos veins, veins along the abdominal wall, and internal mammary veins) were demonstrated in all cases. Liver cirrhosis was combined in all cases and hepatoma developed in 4 cases. Sonography is useful to detect the MOVC and to demonstrate hepatic venous obstruction and intrahepatic collateral vessels. Color doppler sonography is easily performed to show the direction of the blood flow through interconnecting vessels. CT shows the obliterated segment of the IVC clearly and multiple prominent systemic collaterals. In conclusion, Budd-Chiari syndrome caused by MOVC is accurately diagnosed by combined color doppler sonography and CT

  15. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  16. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  17. Demographics of new Undergraduate Medical Imaging and Medical Sonography degree students at CQUniversity, Australia

    International Nuclear Information System (INIS)

    Spuur, Kelly M.; Falconi, Caroline L.; Cowling, Cynthia M.; Bowman, Anita L.; Maroney, Maria A.

    2012-01-01

    Aim: To report the student demographics of the inaugural intake into the Bachelor of Medical Imaging and Bachelor of Medical Sonography/Graduate Diploma of Medical Sonography at CQUniversity, Mackay, Australia. Method: Surveys were distributed to students enrolled in the course MEDI11001 Fundamentals of the Imaging Professions; this course is common to both cohorts in Term 1 of the programs. All students enrolled at the time of the survey were present to participate in the survey. Participation was voluntary. Descriptive statistics were developed from responses and thematic analysis applied to open-ended questions. Results: A total of 44 students were enrolled in the programs. The most common place of residence on enrolment was within 40 km of the Mackay campus (16/36.4%); mature age students (30/68.2%); live on campus in the purpose built residences (18/40.9%) and were influenced by the location of the programs in Mackay to enrol (27/61.2%), with the primary justification for this being that the programs were offered close to home. The university website was identified as the primary source of information regarding the programs (15/34.1%) followed by family and friends (11/25%). The programs were first preference for 31 students (70.5%). The majority (23/52.3%) undertakes some type of paid work. Conclusion: Both programs have attracted a diverse student cohort. The majority of students were mature age students from outside of the area local to the Mackay campus of CQUniversity.

  18. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    International Nuclear Information System (INIS)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon

    2002-01-01

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  19. Color coded duplex sonography. Interdisciplinary vascular ultrasonography; Farbkodierte Duplexsonographie. Interdisziplinaerer vaskulaerer Ultraschall

    Energy Technology Data Exchange (ETDEWEB)

    Kubale, R. [Institut fuer Radiologie, Sonographie und Nuklearmedizin, Pirmasens (Germany); Stiegler, H. [Staedtisches Krankenhaus Schwabing, Muenchen (Germany). 7. Medizinische Abt.

    2002-07-01

    An interdisciplinary team of experts impart the state of the art in color coded duplex sonography applied for examination of all anatomic areas. Detailed information is given for every vascular area, describing the examination procedure, possible origins of mistakes or faults, and means to avoid them. In addition to the classical applications, eg. for examination of the extra- and intracranial vessels, vessels of the limbs, visceral vessels and the vessels of liver and kidney, there are chapters devoted to: haemodialysis shunts, arteriovenous malformations, duplex sonography of the penis, tumor vascularisation. (orig./CB) [German] Ein interdisziplinaeres Autorenteam vermittelt Ihnen den State of the Art der FKDS fuer alle anatomischen Regionen. Fuer jede der Gefaessregionen werden detaillierte Angaben zum Untersuchungsablauf, zu moeglichen Fehlerquellen und zu deren Vermeidung geboten. Neben den klassischen Anwendungen bei der Untersuchung - der extra- und intrakraniellen Gefaesse, - der Extremitaetengefaesse, - der viszeralen Gefaesse sowie der Gefaesse von Niere und Leber finden Sie Kapitel zu den Themen: Haemodialyseshunt, arteriovenoese Malformationen, Duplexsonographie des Penis und Tumorvaskularisation. (orig./AJ)

  20. Emergency Sonography Aids Diagnostic Accuracy of Torso Injuries: A Study in a Resource Limited Setting

    Directory of Open Access Journals (Sweden)

    Charles Edward Tunuka

    2014-01-01

    Full Text Available Introduction. Clinical evaluation of patients with torso trauma is often a diagnostic challenge. Extended focused assessment with sonography for trauma (EFAST is an emergency ultrasound scan that adds to the evaluation of intrathoracic abdominal and pericardial cavities done in FAST (focused assessment with sonography for trauma. Objective. This study compares EFAST (the index test with the routine standard of care (SoC investigations (the standard reference test for torso trauma injuries. Methods. A cross-sectional descriptive study was conducted over a 3-month period. Eligible patients underwent EFAST scanning and the SoC assessment. The diagnostic accuracy of EFAST was calculated using sensitivity and specificity scores. Results. We recruited 197 patients; the M : F ratio was 5 : 1, with mean age of 27 years (SD 11. The sensitivity of EFAST was 100%, the specificity was 97%, the PPV was 87%, and the NPV was 100%. It took 5 minutes on average to complete an EFAST scan. 168 (85% patients were EFAST-scanned. Most patients (82 (48% were discharged on the same day of hospitalization, while 7 (4% were still at the hospital after two weeks. The mortality rate was 18 (9%. Conclusion. EFAST is a reliable method of diagnosing torso injuries in a resource limited context.

  1. Value of sonography in establishing severity of liver cirrhosis:correlation of sonographic features with Childclass

    International Nuclear Information System (INIS)

    Choi, Byung Ihn; KIm, Ho Chul; Shin, Yong Moon; Kim, Chu Wan; Lee, Hyo suk; Kim, Chung Yong

    1993-01-01

    This prospective study was designed to investigate the utility of sonography in establishing severity of liver cirrhosis as compared with Child class in clinical creteria. Seventy-our consecutive patients with liver cirrhosis were examined with sonography. This study included 50 males and 24 females, aged 35 to 72 years (mean ; 51) The number of patients in child A,B, and C group was 30,29,15 respectively. Sonographic features evaluated were hepatic parenchymal echo pattern, presence of nodularity of hepatic surface, degree of hepatic sonic attenuation,degree of obliteration of wall echo of the intrahepatic portal vein, size of the main portal vein, thickness of the gallbladder wall, size of the spleen, and presence of ascites. Each sonographic features was graded from 0 to depending upon the degree of severity, and was correlated with Child class of liver cirrhosis. Hepatic parenchymal echo pattern, presence of nodularity of hepatic surface, thickness of gallbladder wall, and presence of ascites were correlated well with Child class (p 0.05). In conclusion, these results indicate that careful evaluation of sonographic features are helpful in predicting severity of liver cirrhosis

  2. Is there a relationship between ultrasound scanning ability (sonography) and visuospatial perception or psychomotor ability?

    Science.gov (United States)

    Hagen, Suzanne; Gallagher, Helen

    2016-01-01

    Background Competent sonography is thought to include a unique combination of skills not yet fully defined. This presents challenges when recruiting the correct people for training. Skills are thought to include visuospatial perception and psychomotor skills, but little is known about the relationship between these aptitudes and scanning ability. This feasibility study explored such relationships, to identify evaluation techniques which may improve selection and recruitment. Methods A sample of 30 experienced ultrasound practitioners and 30 trainees at commencement and on completion of training were administered eight tests. Results No significant relationships between experienced practitioners’ or trainees’ visuospatial abilities or psychomotor abilities and scanning abilities were found. Results demonstrated that two of the visuospatial perception tests were not influenced by training and therefore, may be measuring the innate skills of ultrasound practitioners. As ultrasound practitioners had not performed any of the tests previously, ranges of scores for each of the eight tests were established for this group. This included measures for psychomotor skills which added to the current body of knowledge for sonography. Conclusions Although no significant correlations were found between participants’ visuospatial perception or psychomotor abilities and scanning ability, performance on the Obstetric Structured Assessment Test (combining all the skills required) pre-training gave the best indication of post-training scanning performance. The Obstetric Structured Assessment Test may prove a useful tool for initial assessment of potential trainees but abilities will require further investigation. PMID:27847536

  3. [Changes of renal blood flow during organ-associated foot reflexology measured by color Doppler sonography].

    Science.gov (United States)

    Sudmeier, I; Bodner, G; Egger, I; Mur, E; Ulmer, H; Herold, M

    1999-06-01

    Using colour Doppler sonography blood flow changes of the right kidney during foot reflexology were determined in a placebo-controlled, double-blind, randomised study. 32 healthy young adults (17 women, 15 men) were randomly assigned to the verum or placebo group. The verum group received foot reflexology at zones corresponding to the right kidney, the placebo group was treated on other foot zones. Before, during and after foot reflexology the blood flow of three vessels of the right kidney was measured using colour Doppler sonography. Systolic peak velocity and end diastolic peak velocity were measured in cm/s, and the resistive index, a parameter of the vascular resistance, was calculated. The resistive index in the verum group showed a highly significant decrease (p foot reflexology. There was no difference between men and women and no difference between smokers and non-smokers. Verum and placebo group significantly differed concerning alterations of the resistive index both between the measuring points before versus during foot reflexology (p = 0.002) and those during versus after foot reflexology (p = 0.031). The significant decrease of the resistive index during foot reflexology in the verum group indicates a decrease of flow resistance in renal vessels and an increase of renal blood flow. These findings support the hypothesis that organ-associated foot reflexology is effective in changing renal blood flow during therapy.

  4. Doppler sonography of diabetic feet: Quantitative analysis of blood flow volume

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Kim, Ho Chul; Choi, Chul Soon; Yoon, Dae Young; Han, Dae Hee; Moon, Jeung Hee; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of)

    2002-09-15

    To analyze Doppler sonographic findings of diabetic feet by estimating the quantitative blood flow volume and by analyzing waveform on Doppler. Doppler sonography was performed in thirty four patients (10 diabetic patients with foot ulceration, 14 diabetic patients without ulceration and 10 normal patients as the normal control group) to measure the flow volume of the arteries of the lower extremities (posterior and anterior tibial arteries, and distal femoral artery. Analysis of doppler waveforms was also done to evaluate the nature of the changed blood flow volume of diabetic patients, and the waveforms were classified into triphasic, biphasic-1, biphasic-2 and monophasic patterns. Flow volume of arteries in diabetic patients with foot ulceration was increased witha statistical significance when compared to that of diabetes patients without foot ulceration of that of normal control group (P<0.05). Analysis of Doppler waveform revealed that the frequency of biphasic-2 pattern was significantly higher in diabetic patients than in normal control group(p<0.05). Doppler sonography in diabetic feet showed increased flow volume and biphasic Doppler waveform, and these findings suggest neuropathy rather than ischemic changes in diabetic feet.

  5. Sonography and dynamic scintigraphy with 99mTc-DTPA in children with nephrotic syndrome

    International Nuclear Information System (INIS)

    Bliznakova, D.; Klisarove, A.

    2000-01-01

    The aim of the study is to assay the clinical application of kidney sonography and dynamic scintigraphy with 99m Tc-DTPA in children presenting nephrotic syndrome. A total of 32 children (mean age 9.5±1.2) are covered by the study, with the most important laboratory investigations being performed. All patients undergo abdominal sonography and dynamic kidney scintigraphy following iv administration of 100 μC/kg 99m Tc-DTPA, and glomerular filtration clarence (GFR) measured by the method of full and empty syringe activity. The functional curves are also shown. In children with primary nephrotic syndrome the sonographic imaging reveals enlarged kidney size and enhanced sonogeneity of parenchyma in the first stage. In patients with secondary nephrotic syndrome increased kidney size is likewise observed with enhanced sonogeneity of parenchyma in second stage and unclear visualization of pyramids. In children with idiopathic nephrotic syndrome the scintigraphic data confirm the enlarged kidneys with moderately increased values of GFR. In the mixed forms of nephrotic syndrome the kidneys preserve their moderate enlargement against the background of heterogeneous GFR values. In 5 patients the functional curves show kidney excretion impairment. The study confirms that sonographic imaging correlates well with the dynamic scintigraphic 99m Tc-DTPA imaging in children with nephrotic syndrome. The functional curves and GFR values promote accurate diagnosing and monitoring of the dynamic pathological processes. (author)

  6. Standard sonography and arthrosonography in the study of rotator cuff tears

    International Nuclear Information System (INIS)

    El-Dalati, Ghassan; Martone, Enrico; Caffarri, Sabrina; Fusaro, Michele; Pozzi Mucelli, Roberto; Castellarin, Gianluca; Ricci, Matteo; Vecchini, Eugenio

    2005-01-01

    Purpose. The aim of this study was to evaluate the sensitivity of ultrasonography, integrating standard ultrasound and arthrosonography after injecting a saline solution into the glenohumeral cavity in cases of suspected rotator cuff tears. Materials and methods. We respectively examinated 40 patients awaiting shoulder arthroscopy for suspected or diagnosed tears of the rotator cuff. A radiologist, unaware of the pre-operative diagnosis, performed an ultrasound scan on all the patients before and after the injection of saline solution into the glenohumeral cavity. The parameters considered were presence or absence of a rotator cuff injury; type of injury according to Snyder and its extent along the longitudinal and transverse planes; presence or absence of effusion into the articular cavity; subacromial/subdeltoid bursal distension. All the patients underwent arthroscopy either the same day of the day after the ultrasound examination. Results. Standard sonography showed 26 complete rotator cuff tears (type C according to Snyder), 2 partial tears (type B according to Snyder) and 12 intact rotator cuffs. Arthrosonography detected 31 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Arthroscopy identified 32 complete rotator cuff tears (type C according to Snyder), 1 partial tear (type B according to Snyder) and 8 intact rotator cuffs. Analysis of the results shows that, taking arthroscopy as the gold standard, the sensitivity of normal sonography is 81.2%, whereas that of arthosonography is 96.8% (p [it

  7. Sonography of acute appendicitis in pregnant women: diagnostic accuracy by the stage of gestation

    International Nuclear Information System (INIS)

    Kim, Sam Soo; Lee, Sang Wook; Rho, Myung Ho

    2004-01-01

    To evaluate the diagnostic accuracy of a diagnosis of acute appendicitis in pregnant women according to the trimester. A retrospective review was performed on 103 pregnant women who underwent sonography with clinically suspected acute appendicitis. The sonographic technique used involved either the graded compression or a non-compression method. All the sonograms were obtained after changing the patient's position and identifying the diseased appendix. The criterion for a sonographic diagnosis of acute appendicitis was the visualization of a non-compressible appendix with a maximal diameter ≥ 6 mm. The sonographic findings were correlated with the surgical findings and clinical follow-up. Acute appendicitis was confirmed by both the surgical and pathological findings in 48 out of 103 pregnant women. Ultrasound established the diagnosis in 34 of the 48 patients with proven appendicitis. There were false-positives in 2 patients and false-negatives in 14 patients. Among the 55 patients who had a normal appendix, 30 patients improved at the clinical follow-up and 25 patients had other intra-abdominal disorders. The diagnostic accuracy of the ultrasound was 94% in the first trimester, 81% in the second trimester, and 76% in the third trimester. The overall accuracy was found to be 84%, with a 71% sensitivity and a 96% specificity. No significant difference was found in the diagnostic accuracy of the ultrasound according to the trimester in which the acute appendicitis occurred. Therefore, regardless of the stage of gestation, sonography is a valuable procedure for diagnosing acute appendicitis

  8. MRI, CT, and sonography in the preoperative evaluation of primary tumor extension in malignant pleural mesothelioma; MRT, CT und Sonographie in der praeoperativen Beurteilung der Primaertumorausdehnung beim malignen Pleuramesotheliom

    Energy Technology Data Exchange (ETDEWEB)

    Layer, G.; Steudel, A.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Schmitteckert, H.; Tuengerthal, S.; Schirren, J. [Thoraxklinik Heidelberg-Rohrbach (Germany); Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Schwerpunkt fuer Onkologische Diagnostik und Therapie

    1999-04-01

    Purpose: Evaluation of the diagnostic value of the imaging modalities computed tomography (CT), magnetic resonance imaging (MRI), and thoracic sonography in the preoperative staging of malignant pleural mesothelioma. Results: The accuracy rates for CT were 85%, 98%, 83%, 73%, 71%, and 83%. MRI had an accuracy of 71%, 92%, 71%, 83%, 71%, and 96%, the thoracic ultrasound examinations of 76%, 63%, 51%, 60%, 71% and 89%. Conclusions: According to these results CT remains the method of choice in the preoperative assessment of T-stage of malignant pleural mesothelioma. MRI is of nearly the same value, but is not a must. Sonography may be supplementary method for operation planning. (orig./AJ) [Deutsch] Ziel: Evaluation der diagnostischen Wertigkeit der Schnittbildverfahren MRT, CT und Sonographie in der praeoperativen Diagnostik des Pleuramesothelioms. Ergebisse: Die Treffsicherheiten betrugen fuer die genannten anatomischen Regionen im CT 85%, 98%, 83%, 73%, 71%, und 83%, im MRT 71%, 92%, 71%, 83%, 71% bzw. 96%, waehrend sich fuer die thorakale Ultraschalluntersuchung Treffsicherheiten von 76%, 63%, 51%, 60%, 71% und 89% errechneten. Schlussfolgerungen: Die CT bleibt damit das Verfahren erster Wahl in der praeoperativen Diagnostik des malignen Pleuramesothelioms. Eine unbedingte Forderung nach praeoperativer Durchfuehrung einer MRT-Untersuchung ergibt sich nach der vorliegenden Studie nicht. Die Sonographie des Thorax und oberen Abdomens liefert einen wichtigen ergaenzenden Beitrag bei der Planung der Operation des malignen Pleuramesothelioms. (orig./AJ)

  9. Comparison of sonography and magnetic resonance imaging for the diagnosis of partial tears of finger extensor tendons in rheumatoid arthritis

    NARCIS (Netherlands)

    Swen, W. A.; Jacobs, J. W.; Hubach, P. C.; Klasens, J. H.; Algra, P. R.; Bijlsma, J. W.

    2000-01-01

    Finger extensor tenosynovitis in rheumatoid arthritis (RA) may lead to partial and eventually to complete tendon tears. The aim of this study was to investigate the diagnostic value of sonography (SG) and/or magnetic resonance imaging (MRI) to visualize partial tendon tears. Twenty-one RA patients

  10. MR imaging-guided sonography followed by fine-needle aspiration cytology in occult carcinoma of the breast

    NARCIS (Netherlands)

    A.I.M. Obdeijn (Inge-Marie); Brouwers-Kuyper, E.M.; M.M.A. Tilanus-Linthorst (Madeleine); T. Wiggers (Theo); M. Oudkerk (Matthijs)

    2000-01-01

    markdownabstractOBJECTIVE. In patients with axillary metastases as clinical evidence of possible occult breast cancer, a combined approach of MR imaging, sonography, and aspiration biopsy cytology was evaluated. SUBJECTS AND METHODS. Thirty-one women with metastatic adenocarcinoma in their

  11. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    Science.gov (United States)

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  13. A comparison of magnetic resonance imaging, sonography, and radiography of the hand in patients with early rheumatoid arthritis

    NARCIS (Netherlands)

    Hoving, Jan Lucas; Buchbinder, Rachelle; Hall, Stephen; Lawler, Gary; Coombs, Peter; McNealy, Stephen; Bird, Paul; Connell, David

    2004-01-01

    OBJECTIVE: As therapy for rheumatoid arthritis (RA) becomes more effective, more sensitive imaging methods are required to assess disease activity and joint damage. We compared magnetic resonance imaging (MRI), sonography, and radiography for assessment of disease activity for the detection of bony

  14. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  15. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  16. Treatment response assessment of radiofrequency ablation for hepatocellular carcinoma: Usefulness of virtual CT sonography with magnetic navigation

    International Nuclear Information System (INIS)

    Minami, Yasunori; Kitai, Satoshi; Kudo, Masatoshi

    2012-01-01

    Purpose: Virtual CT sonography using magnetic navigation provides cross sectional images of CT volume data corresponding to the angle of the transducer in the magnetic field in real-time. The purpose of this study was to clarify the value of this virtual CT sonography for treatment response of radiofrequency ablation for hepatocellular carcinoma. Patients and methods: Sixty-one patients with 88 HCCs measuring 0.5–1.3 cm (mean ± SD, 1.0 ± 0.3 cm) were treated by radiofrequency ablation. For early treatment response, dynamic CT was performed 1–5 days (median, 2 days). We compared early treatment response between axial CT images and multi-angle CT images using virtual CT sonography. Results: Residual tumor stains on axial CT images and multi-angle CT images were detected in 11.4% (10/88) and 13.6% (12/88) after the first session of RFA, respectively (P = 0.65). Two patients were diagnosed as showing hyperemia enhancement after the initial radiofrequency ablation on axial CT images and showed local tumor progression shortly because of unnoticed residual tumors. Only virtual CT sonography with magnetic navigation retrospectively showed the residual tumor as circular enhancement. In safety margin analysis, 10 patients were excluded because of residual tumors. The safety margin more than 5 mm by virtual CT sonographic images and transverse CT images were determined in 71.8% (56/78) and 82.1% (64/78), respectively (P = 0.13). The safety margin should be overestimated on axial CT images in 8 nodules. Conclusion: Virtual CT sonography with magnetic navigation was useful in evaluating the treatment response of radiofrequency ablation therapy for hepatocellular carcinoma.

  17. Local recurrences after conservative surgery and irradiation for breast cancer: Diagnosis with mammography and ultrasound. Mammographie und Sonographie in der Rezidivdiagnostik nach brusterhaltender Therapie des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Hamberger, L; Schoen, G [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Steixner, G; Fritsch, E [Innsbruck Univ. (Austria). Universitaetsklinik fuer Strahlentherapie

    1991-06-01

    89 patients, who underwent conservative surgery for breast cancer were followed up with mammography and real-time sonography. 78 patients underwent postoperative irradiation. Depending on the time interval between irradiation and examination various alterations in mammographic and sonographic patterns were evident. Of 14 biospy-confirmed local recurrences, 11 were diagnosed by mammography and 12 by sonography. Combined use of mammography and sonography should therefore lead to better results in the diagnosis of local recurrences and to a reduction of unnecessary biopsies. (orig./GDG).

  18. Evaluation of clinical efficacy of transrectal sonography and computed tomography for prostatic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroki; Ohe, Hiroshi; Tanahashi, Toshikatsu and others

    1988-07-01

    Receiver operating characteristics (ROC) analysis was performed to evaluate the clinical efficacy of transrectal sonography (US) and computed tomography (CT) for prostatic diseases. One hundred US and CT images of prostatic diseases collected from 10 medical institutions, including 33 cases of prostatic cancer, 29 of benign prostatic hypertrophy, 7 of prostatitis, 2 of prostatic stone and 29 of normal finding, were read by 21 urologists. As the results, US was found to be more useful than CT for both the detection of prostatic diseases and the differentiation between prostatic cancer and benign prostatic hypertrophy. The sensitivity of US for the diagnosis of prostatic cancer was 64.2 % on average of all the urologists. However, the sensitivity was 80.0 % on average of 5 urologists who have read more than 3,000 US images and 59.5 % on average of 16 doctors who have read within 3,000 US images.

  19. Assessment of the validity of sonography, computed tomography and angiography in diagnosis of the adrenals

    International Nuclear Information System (INIS)

    Georgi, M.; Hofbauer, J.; Weiss, H.; Keller, W.; Wunschik, F.; Mittelstaedt, G. von; Linder, M.; Heidelberg Univ., Mannheim; Heidelberg Univ., Mannheim

    1984-01-01

    Between 1979 and 1982, 47 patients with pathological process of the adrenals were surgically treated after preceding thorough non-evasive angiographic diagnosis (6 phaeochromocytomas, 20 adrenal adenomas, 8 adrenal hyperplasias, 5 adrenal carcinomas, 5 adrenal cysts and 3 adrenal metastases). The most consistently accurate results were obtained via adrenal phlebography with an accuracy of 94%. This was followed by non-evasive computed tomography (87%). Compared with the data given in literature, hormone determination in the adrenal venous blood was less favourable (79%). Selective adrenal arteriography, which was used less often, yielded correct results in 83% of the cases, whereas the number of accurate diagnoses achieved via sonography was lowest with 54%. (orig.) [de

  20. Investigating language lateralization during phonological and semantic fluency tasks using functional transcranial Doppler sonography

    Science.gov (United States)

    Gutierrez-Sigut, Eva; Payne, Heather; MacSweeney, Mairéad

    2015-01-01

    Although there is consensus that the left hemisphere plays a critical role in language processing, some questions remain. Here we examine the influence of overt versus covert speech production on lateralization, the relationship between lateralization and behavioural measures of language performance and the strength of lateralization across the subcomponents of language. The present study used functional transcranial Doppler sonography (fTCD) to investigate lateralization of phonological and semantic fluency during both overt and covert word generation in right-handed adults. The laterality index (LI) was left lateralized in all conditions, and there was no difference in the strength of LI between overt and covert speech. This supports the validity of using overt speech in fTCD studies, another benefit of which is a reliable measure of speech production. PMID:24875468

  1. CASAD -- Computer-Aided Sonography of Abdominal Diseases - the concept of joint technique impact

    Directory of Open Access Journals (Sweden)

    T. Deserno

    2010-03-01

    Full Text Available Ultrasound image is the primary (input information for every ultrasonic examination. Since being used in ultrasound images analysis the both knowledge-base decision support and content-based image retrieval techniques have their own restrictions, the combination of these techniques looks promissory for covering the restrictions of one by advances of another. In this work we have focused on implementation of the proposed combination in the frame of CASAD (Computer-Aided Sonography of Abdominal Diseases system for supplying the ultrasound examiner with a diagnostic-assistant tool based on a data warehouse of standard referenced images. This warehouse serves: to manifest the diagnosis when the ecographist specifies the pathology and then looks through corresponding images to verify his opinion; to suggest a second opinion by automatic analysis of the annotation of relevant images that were assessed from the repository using content-based image retrieval.

  2. Sonography and computerized tomography in a comparison in renal mass diseases

    International Nuclear Information System (INIS)

    Brommer, M.

    1981-01-01

    One hundred and thirteen patients with renal mass processes were examined sonographically and by computized tomography. The diagnosis was assured in 32 cases histologically, in 40 cases angiographically clinically and by the course and in 41 cases only clinically and by the course resp. by sonographic and computerized tomography control studies. The accuracy of a hit in sonography is smaller compared with computerized tomography with fast image formation. However, due to its relative safety, it is judged as the most useful technique for a first diagnossis of renal masses after ureographic diagnostic of excreta. A diagnostic procedure is proposed in which the number of necessary angiographies and diagnostic sampling surgery can be considerably reduced. (orig.) [de

  3. Transcranial brainstem sonography as a diagnostic tool for amyotrophic lateral sclerosis.

    Science.gov (United States)

    Prell, Tino; Schenk, Annekathrin; Witte, Otto W; Grosskreutz, Julian; Günther, Albrecht

    2014-06-01

    Diagnosing amyotrophic lateral sclerosis (ALS) can be difficult, particularly in the early stage of disease; therefore, we evaluated the use of transcranial stem sonography (TCS) to improve early detection of the disease. In this cross-sectional study, 94 patients with sporadic ALS and 46 age- and gender-matched healthy controls were evaluated by TCS according to a standardized protocol used to diagnose Parkinson's disease. Approximately half (48%) of the patients with ALS showed a clear (> 0.25 cm(2)) mesencephalic hyperechogenic structure, 20% showed a possible (laterally. In conclusion, although the neuropathological correlation to hyperechogenicity remains unclear, TCS is an easy, feasible and reproducible technique that could serve as an additional diagnostic tool and as a surrogate biomarker in ALS.

  4. Sonography and MRI of latissimus dorsi strain injury in four elite athletes

    International Nuclear Information System (INIS)

    Pedret, Carles; Balius, Ramon; Idoate, Fernando

    2011-01-01

    The objective of this study was to describe the MR and sonographic findings in latissimus dorsi (LD) muscle strain in athletes, and to review the most common injuries described in the literature, most of which are humeral avulsions. Four injuries and two reinjuries of the myotendinous junction of the LD were followed from the day of injury until the return to play. Sonography (US) and MR imaging were performed in each case to confirm the diagnosis and to monitor the healing process. All cases had acute and isolated pain in the back of the shoulder while performing an eccentric maneuver of the arm and the shoulder. US and MR images demonstrated that injuries were located in the middle and cranial portion of the latissimus dorsi surrounding the myotendinous junction. After rehabilitation, all players played at high level again. Isolated lesions of LD are very rare. They can be demonstrated by US and MR images. (orig.)

  5. Importance of sonography in the evaluation of urinary tract infections in children

    International Nuclear Information System (INIS)

    Zocchi, M.; Ferrero, C.G.

    1988-01-01

    One undred and twenty-one children with a clinical diagnosis of urinary tract infection (UTI) were examined with sonography (US), ivp and voiding cystouretrography (VCUG). In 84 patients neither US nor radiography findings were found of pathological findings both US and ivp were negative, whereas VCUG was decisive for a correct diagnosis. VCUG demonstrated vesicouretericreflux in 10 patients, posterior urotheral valves in 1 patient, and small diverticula of the urinary bladder in 5 patients. In 17 of the remaining 21 cases, there was agreementbetween US and urographic findings, whereas in 4 cases US provided us with false positives, with images of apparent renal scarring. the mistake was caused by an incorrect US detection of unilateral duplication of the collecting systems. The authors conclude by stressing the importance of ivp in the evaluetion of urinary tract infections in children, even in case of negative VCUG and US results, and suggest comparing US measurements comparable to body growth

  6. Role of sonography in the recognition, assessment, and treatment of cesarean scar ectopic pregnancies.

    Science.gov (United States)

    McKenna, David A; Poder, Liina; Goldman, Mindy; Goldstein, Ruth B

    2008-05-01

    Cesarean scar ectopic pregnancies (CSEPs) are rare but may have serious adverse consequences and are therefore important to promptly recognize on sonography. We aim to describe the typical sonographic appearances. Potential treatments are discussed, including sonographic guidance for transcervical injection of methotrexate (MTX) into the gestational sac. Two patients with CSEPs were treated with systemic and intra-amniotic administration of MTX under sonographic guidance. Both patients were followed clinically after medical treatment, resulting in low maternal morbidity and mortality. Considering the increasing rate of cesarean delivery and the increased risk of CSEPs, sonologists should be familiar with the sonographic appearances of a pregnancy implanted into the cesarean scar. We show how to correctly diagnose scar implantation and describe how to perform sonographically guided transcervical injection of MTX.

  7. Sonography and MRI of latissimus dorsi strain injury in four elite athletes

    Energy Technology Data Exchange (ETDEWEB)

    Pedret, Carles [Unitat Medicina Esportiva Consorci Sanitari del Garraf, Barcelona (Spain); Centre Diagnostic per Imatge de Tarragona, Tarragona (Spain); Balius, Ramon [Generalitat of Catalonia, Sports Catalan Council, Catalonia (Spain); Idoate, Fernando [Clinica San Miguel, Department of Radiology, Pamplona (Spain)

    2011-05-15

    The objective of this study was to describe the MR and sonographic findings in latissimus dorsi (LD) muscle strain in athletes, and to review the most common injuries described in the literature, most of which are humeral avulsions. Four injuries and two reinjuries of the myotendinous junction of the LD were followed from the day of injury until the return to play. Sonography (US) and MR imaging were performed in each case to confirm the diagnosis and to monitor the healing process. All cases had acute and isolated pain in the back of the shoulder while performing an eccentric maneuver of the arm and the shoulder. US and MR images demonstrated that injuries were located in the middle and cranial portion of the latissimus dorsi surrounding the myotendinous junction. After rehabilitation, all players played at high level again. Isolated lesions of LD are very rare. They can be demonstrated by US and MR images. (orig.)

  8. [Preoperatory sonography efficiency in paediatric patients with cholelithiasis undergoing laparoscopic cholecystectomy].

    Science.gov (United States)

    Riñón, C; de Mingo, L; Cortés, M J; Ollero, J C; Alvarez, M; Espinosa, R; Rollán, V

    2009-01-01

    Biliary lithiasis is not much frequent in paediatric patients. The manegement of cholelithiasis in patients undergoing laparoscopic cholecystectomy is still controversial. We propose the preoperatory echographic study of the biliary tree 24-48 h before surgery, as the first choice, instead of the intraoperatory cholangiography. We made a retrospective study of 42 patients undergoing laparoscopic cholecystectomy due to symptomatic biliary lithiasis during the last 15 years, with ages between 18 months and 17-years-old (mean age 9,6-years-old) and weight between 11 and 70 kg (mean weight 42 kg) at the moment of surgery. Six of them had haematological illnesses, 17 came to the hospital because of acute abdominal pain, 10 had been studied because of recurrent abdominal pain and 9 had casual diagnoses. Abdominal sonography was performed in all patients 24-48 hours before surgery. Four children were diagnosed of biliary duct lithiasis: two choledocolithiasis and two stones in the cystic duct. One of the cystic stones was extracted in the operating room and the rest resolved spontaneously. One patient presented dilatation of choledocal duct after surgery, without any stones' evidence. Also this patient resolved spontaneously. We had no complications. Biliary lithiasis is not frequent in children, even if it seems to be increasing. A few of these patients will suffer of choledocolithiasis. The intraoperatory exploration of the biliary tree during laparoscopic surgery is technically difficult due the small size of paediatric patients. Cholangiography is not always successful and can produce some important complications as pancreatitis. Preoperative sonography 24-48 hours before surgery is a safe and efficient method for the diagnosis and follow-up of paediatric patients with biliary lithiasis undergoing laparoscopic cholecystectomy. It is safe enough to be performed without intraoperatory cholangiography.

  9. Off ice Hysteroscopy in Patients with Abnormal Uterine Bleeding and Normal Transvaginal Sonography

    Directory of Open Access Journals (Sweden)

    Mojgan Barati

    2008-01-01

    Full Text Available Background: Abnormal uterine bleeding (AUB is one of the most common clinical problemsin gynecology. Transvaginal sonography (TVS and hysteroscopy are two diagnostic methods forpatients with AUB. For most of the patients with AUB, diagnostic hysteroscopy can be done inclinic with minimal discomfort and much lower expense than operative room.Materials and Methods: In our clinical trial study, from March 21, 2005 to March 20, 2007,patients with AUB in Ahwaz Imam Khomayni hospital, after history and physical examinationsunderwent TVS. Of those, 147 patients with normal TVS entered the study and were considered foroutpatient hysteroscopy. Patients with endometrial cavity lesion were scheduled for operation room,and those with empty endometrial cavity aspiration biopsy were done outpatiently. Specimens weresent to pathologist for examination.Results: All the patients were divided into three groups: group 1 or minority was under 30 yearsold (7 women, group 2 was 30-40 years, and group 3 or majority was over 40 years old (96women. 115 patients (78.2% had normal and 32 patients (21.8% had abnormal hysteroscopicresults. 116 patients (78.8% had normal and 31 patients (21.2% had abnormal pathologic results;moreover, cervical canal polyp was the most common lesion hysteroscopically and pathologicallyin all groups.Conclusion: Of 147 patients (100% with AUB and normal TVS, 32 patients (21.8% wereabnormal hysteroscopically. Cervical canal polyps may be missed by transvaginal sonography, butcan be diagnosed by hysteroscopy. In patients with AUB and normal TVS, hysteroscopy can beused as the second step.

  10. Diagnostic Accuracy of Transvaginal Sonography, Sonohysterography and Office Hysteroscopy in the Evaluation of Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    Ümit Göktolga

    2007-06-01

    Full Text Available OBJECTIVE: To find out the diagnostic accuracy of transvaginal sonography (TVS and saline infusion sonography (SIS by comparing the results with hysteroscopy (HSC and hystological reports obtained by endometrial biopsies in pre and postmenopausal women with abnormal uterine bleeding (AUB.\tDesign: Prospective study\tSetting: women presenting with abnormal uterine bleeeding as an outpatient procedure, in Gülhane Military Medical Faculty, between June 01, 2004 – August 01, 2005.\tPatients: 38 premenopausal and 6 postmenopausal patients\tInterventions: TVS and SIS was performed at the same seance and they underwent hysteroscopy and hysteroscopic biopsy one week later.\tMain outcome measures: The findings at TVS and SIS were compared with the hysteroscopic views and histologic findings. The sensitivity and spesifity ratios of all three methods were calculated in defining the endometrial and intracavitary pathologies.\tRESULTS: The sensitivity ratios of TVS and SIS in defining endometrial pathologies was 36.4% and 33.8% respectively and the sensitivity of hysteroscopy was lower. (%28.6, p=0.24 In the comparison of spesifity ratios sonohysterography had a higher ratio than others. (TVS vs SIS, p=0.08; HSC vs SIS, p=0.07 As a result; in outpatient group, hysteroscopy gives not much more information than SIS.\tThe detection rate of focal intrauterine pathology (polyp/submucous myoma using conventional TVS was significantly lower than sonohysterography. (sensitivity ratios; 46.5% and 97.1% respectively; p=0.0009 The sensitivity ratios of hysteroscopy (100% and SIS (97.1 was similar. (p=0.98\tCONCLUSIONS: Sonohysterography is a current, trustable method which can replace office hysteroscopy in the diagnosis and evaluation of cases presenting with AUB especially in outpatient group.

  11. Using Acoustic Structure Quantification During B-Mode Sonography for Evaluation of Hashimoto Thyroiditis.

    Science.gov (United States)

    Rhee, Sun Jung; Hong, Hyun Sook; Kim, Chul-Hee; Lee, Eun Hye; Cha, Jang Gyu; Jeong, Sun Hye

    2015-12-01

    This study aimed to evaluate the usefulness of Acoustic Structure Quantification (ASQ; Toshiba Medical Systems Corporation, Nasushiobara, Japan) values in the diagnosis of Hashimoto thyroiditis using B-mode sonography and to identify a cutoff ASQ level that differentiates Hashimoto thyroiditis from normal thyroid tissue. A total of 186 thyroid lobes with Hashimoto thyroiditis and normal thyroid glands underwent sonography with ASQ imaging. The quantitative results were reported in an echo amplitude analysis (Cm(2)) histogram with average, mode, ratio, standard deviation, blue mode, and blue average values. Receiver operating characteristic curve analysis was performed to assess the diagnostic ability of the ASQ values in differentiating Hashimoto thyroiditis from normal thyroid tissue. Intraclass correlation coefficients of the ASQ values were obtained between 2 observers. Of the 186 thyroid lobes, 103 (55%) had Hashimoto thyroiditis, and 83 (45%) were normal. There was a significant difference between the ASQ values of Hashimoto thyroiditis glands and those of normal glands (P thyroiditis were significantly greater than those in patients with normal thyroid glands. The areas under the receiver operating characteristic curves for the ratio, blue average, average, blue mode, mode, and standard deviation were: 0.936, 0.902, 0.893, 0.855, 0.846, and 0.842, respectively. The ratio cutoff value of 0.27 offered the best diagnostic performance, with sensitivity of 87.38% and specificity of 95.18%. The intraclass correlation coefficients ranged from 0.86 to 0.94, which indicated substantial agreement between the observers. Acoustic Structure Quantification is a useful and promising sonographic method for diagnosing Hashimoto thyroiditis. Not only could it be a helpful tool for quantifying thyroid echogenicity, but it also would be useful for diagnosis of Hashimoto thyroiditis. © 2015 by the American Institute of Ultrasound in Medicine.

  12. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    Science.gov (United States)

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  13. Optimization of Region of Interest Drawing for Quantitative Analysis: Differentiation Between Benign and Malignant Breast Lesions on Contrast-Enhanced Sonography.

    Science.gov (United States)

    Nakata, Norio; Ohta, Tomoyuki; Nishioka, Makiko; Takeyama, Hiroshi; Toriumi, Yasuo; Kato, Kumiko; Nogi, Hiroko; Kamio, Makiko; Fukuda, Kunihiko

    2015-11-01

    This study was performed to evaluate the diagnostic utility of quantitative analysis of benign and malignant breast lesions using contrast-enhanced sonography. Contrast-enhanced sonography using the perflubutane-based contrast agent Sonazoid (Daiichi Sankyo, Tokyo, Japan) was performed in 94 pathologically proven palpable breast mass lesions, which could be depicted with B-mode sonography. Quantitative analyses using the time-intensity curve on contrast-enhanced sonography were performed in 5 region of interest (ROI) types (manually traced ROI and circular ROIs of 5, 10, 15, and 20 mm in diameter). The peak signal intensity, initial slope, time to peak, positive enhancement integral, and wash-out ratio were investigated in each ROI. There were significant differences between benign and malignant lesions in the time to peak (P benign and malignant lesions in the time to peak (P benign and malignant breast lesions. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Limits of the values of thermography in the diagnosis of malignomas of the thyroid - compared with scintigraphy and sonography

    International Nuclear Information System (INIS)

    Kaick, G. van

    1976-01-01

    In 250 patients suffering from various diseases of the thyroid, infrared thermography was tried out in addition to the common methods of examination such as scintiscanning, ultrasonic examination, and puncture with fine needles. These examinations were carried out using the camera videosystem made by Messrs. Rank. The thermopictures consist of 20,000 dots and are produced at a rate of 45 pictures per second. The measurements were made after exposing the bare throat to the constant room temperature of 19 0 for 15 minutes for adaptation. The results of the test indicate that most of the malignant growths on the thyroid can be detected by clinical diagnosis alone. The combination of cold scintiscanning, solid sonography, and thermography will probably enable a better and more specific diagnosis. Thermography and sonography alone are not suitable as screening methods for diagnosing malignant growths in the thyroid. (GSE) [de

  15. Comparative assessment of renal Tc-99m DMSA scan and renal sonography findings in complication of urinary tract infections

    International Nuclear Information System (INIS)

    Alavi, M.; Rasekhi, A.

    2002-01-01

    Urinary tract infection is a common disease in childhood specially in female. In this study 50 patients with established diagnosis of urinary tract infection were evaluated by both renal scan with Tc-99m DMSA and renal sonography. The study revealed that most urinary tract infections are in children, female sex between 5-9 years of age. Therefore the most important complications (renal scarring) are also common in this age-sex distribution. Occurrence of renal scars increase with increasing the number of recurrent infections. Vesicoureteral reflux is one of the most important, common risk factors for renal scarring. Renal Tc-99m Dmsa scan is more sensitive than renal sonography in detecting the renal scars

  16. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  17. Targeted hepatic sonography during clinic visits for detection of fatty liver in overweight children: a pilot study.

    Science.gov (United States)

    Perito, Emily R; Tsai, Patrika M; Hawley, Sarah; Lustig, Robert H; Feldstein, Vickie A

    2013-04-01

    The purpose of this study was to assess the feasibility and utility of targeted hepatic sonography to evaluate for hepatic steatosis during a subspecialty clinic visit. In this pilot study, we performed targeted hepatic sonography on 25 overweight children aged 7 to 17 years consecutively seen in a pediatric obesity clinic. Long-axis images of the right lobe of the liver and a split-screen image of liver and spleen were taken. Images were interpreted in real time by the radiologist and shown to the family. Demographics, clinical measurements, and laboratory parameters were also collected from the specialty clinic visit on the same day. Sonography required a median of 4 minutes during the visit (interquartile range, 3-5 minutes). All consented patients completed the study. The median alanine aminotransferase (ALT) level was 23 U/L in those with no steatosis (n = 14), 26 U/L with mild steatosis (n = 6), and 41 U/L with moderate/marked steatosis (n = 5). Children with ALT levels of 25 to 50 U/L had very variable sonographic measures of hepatic steatosis. When the participants were categorized by the overall degree of fatty liver, hepatic steatosis was significantly associated with the aspartate aminotransferase level (P = .028), ALT level (P = .003), and diastolic blood pressure (P = .05) but did not correlate with age, sex, Latino race, or insulin resistance. Targeted hepatic sonography added information not apparent from routine ALT screening and provided immediate feedback to clinicians and families about the effect of obesity on end organs. This examination could be a feasible, informative addition to screening for children at high risk for nonalcoholic fatty liver disease who are seen in clinics that specialize in obesity.

  18. False negative pericardial Focused Assessment with Sonography for Trauma examination following cardiac rupture from blunt thoracic trauma: a case report.

    Science.gov (United States)

    Baker, Laura; Almadani, Ammar; Ball, Chad G

    2015-07-15

    The Focused Assessment with Sonography for Trauma examination is an invaluable tool in the initial assessment of any injured patient. Although highly sensitive and accurate for identifying hemoperitoneum, occasional false negative results do occur in select scenarios. We present a previously unreported case of survival following blunt cardiac rupture with associated negative pericardial window due to a concurrent pericardial wall laceration. A healthy 46-year-old white woman presented to our level 1 trauma center with hemodynamic instability following a motor vehicle collision. Although her abdominal Focused Assessment with Sonography for Trauma windows were positive for fluid, her pericardial window was negative. After immediate transfer to the operating room in the setting of persistent instability, a subsequent thoracotomy identified a blunt cardiac rupture that was draining into the ipsilateral pleural space via an adjacent tear in the pericardium. The cardiac injury was controlled with digital pressure, resuscitation completed, and then repaired using standard cardiorrhaphy techniques. Following repair of her injuries (left ventricle, left atrial appendage, and liver), her postoperative course was uneventful. Evaluation of the pericardial space using Focused Assessment with Sonography for Trauma is an important component in the initial assessment of the severely injured patient. Even in cases of blunt mechanisms however, clinicians must be wary of occasional false negative pericardial ultrasound evaluations secondary to a concomitant pericardial laceration and subsequent decompression of hemorrhage from the cardiac rupture into the ipsilateral pleural space.

  19. Ultrasonography-guided percutaneous radiofrequency ablation of hepatocellular carcinomas: A feasibility scoring system for planning sonography

    International Nuclear Information System (INIS)

    Rhim, Hyunchul; Choi, Dongil; Kim, Young-sun; Lim, Hyo K.; Choe, Bong-Keun

    2010-01-01

    Purpose: This study was designed to evaluate whether a feasibility scoring system for planning sonography is a reliable predictor of a safe and complete ablation in ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs). Materials and methods: We retrospectively evaluated the therapeutic outcomes of 108 consecutive patients (M:F, 78:30; mean age, 57.4 years) with a single nodular HCC (mean diameter, 2.0 cm) treated by percutaneous RFA. All patients were assessed for the feasibility of performing an RFA at planning sonography prior to the ablation. The feasibility scoring system consisted of five categories: the safe electrode path (P); the vital organs adjacent to the RFA zone (O); tumor size (S); tumor conspicuity (C); and the heat-sink effect (H). Each category was divided into a four-point scale [1-4]. If a score of 4 in any category was determined, the patient was not considered to be a suitable candidate for percutaneous RFA. We assessed if the score of each category, safety score (P + O), and curability score (S + C + H) correlated with a safe and complete ablation using the chi-squared test and likelihood ratio test for trend. Results: The technical success rate was 100% (108/108) based on CT images obtained immediately after ablation. There was no 30-day mortality after RFA. There were major complications (one case of severe vasovagal reflex, one case of hemoperitoneum and one case of a pseudoaneurysm) in three (2.7%) patients, and minor complications (one case of a biloma, one case of subsegmental infarction and one case of abscess) in three (2.7%) patients. Post-ablation syndrome as a side effect was noted in 38 (35.1%) of 108 patients. The primary technique effectiveness rate at 1 month was 95.1% (105/108). Local tumor progression was noted in eight (7.6%) of 105 patients during the follow-up period (range, 3.0-11.5 months; median, 5.8 months; mean, 5.7 months). There was no significant single category

  20. Soft-copy sonography: cost reduction sensitivity analysis in a pediatric hospital.

    Science.gov (United States)

    Don, S; Albertina, M J; Ammann, D

    1998-03-01

    Our objective was to determine whether interpreting sonograms of pediatric patients using soft-copy (computer workstation) instead of laser-printed film could reduce costs for a pediatric radiology department. We used theoretic models of growth to analyze costs. The costs of a sonographic picture archiving and communication system (three interface devices, two workstations, a network server, maintenance expenses, and storage media costs) were compared with the potential savings of eliminating film and increasing technologist efficiency or reducing the number of technologists. The model was based on historic trends and future capitation estimates that will reduce fee-for-service reimbursement. The effects of varying the study volume and reducing technologists' work hours were analyzed. By converting to soft-copy interpretation, we saved 6 min 32 sec per examination by eliminating film processing waiting time, thus reducing examination time from 30 min to 24 min. During an average day of 27 examinations, 176 min were saved. However, 33 min a day were spent retrieving prior studies from long-term storage; thus, 143 extra minutes a day were available for scanning. This improved efficiency could result in five more sonograms a day obtained by converting to soft-copy interpretation, using existing staff and equipment. Alternatively, five examinations a day would equate to one half of a full-time equivalent technologists position. Our analysis of costs considered that the hospital's anticipated growth of sonography and the depreciation of equipment during 5 years resulted in a savings of more than $606,000. Increasing the examinations by just 200 sonograms in the first year and no further growth resulted in a savings of more than $96,000. If the number of sonograms stayed constant, elimination of film printing alone resulted in a loss of approximately $157,000; reduction of one half of a full-time equivalent technologist's position would recuperate approximately $134

  1. Determination of hemispheric dominance with mental rotation using functional transcranial Doppler sonography and FMRI.

    Science.gov (United States)

    Hattemer, Katja; Plate, Annika; Heverhagen, Johannes T; Haag, Anja; Keil, Boris; Klein, Karl Martin; Hermsen, Anke; Oertel, Wolfgang H; Hamer, Hajo M; Rosenow, Felix; Knake, Susanne

    2011-01-01

    the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly. regional brain activation and hemispheric dominance during mental rotation (cube perspective test) were investigated in 10 female and 10 male healthy subjects using fMRI and fTCD. significant activation was found in the superior parietal lobe, at the parieto-occipital border, in the middle and superior frontal gyrus bilaterally, and the right inferior frontal gyrus using fMRI. Men showed a stronger lateralization to the right hemisphere during fMRI and a tendency toward stronger right-hemispheric activation during fTCD. Furthermore, more activation in frontal and parieto-occipital regions of the right hemisphere was observed using fMRI. Hemispheric dominance for mental rotation determined by the 2 methods correlated well (P= .008), but did not show concordant results in every single subject. the neural basis of mental rotation depends on a widespread bilateral network. Hemispheric dominance for mental rotation determined by fMRI and fTCD, though correlating well, is not always concordant. Hemispheric lateralization of complex cortical functions such as spatial rotation therefore should be investigated using multimodal imaging approaches, especially if used clinically as a tool for the presurgical evaluation of patients undergoing neurosurgery. Copyright © 2009 by the American Society of Neuroimaging.

  2. Focused abdominal sonography for trauma in the clinical evaluation of children with blunt abdominal trauma.

    Science.gov (United States)

    Ben-Ishay, Offir; Daoud, Mai; Peled, Zvi; Brauner, Eran; Bahouth, Hany; Kluger, Yoram

    2015-01-01

    In pediatric care, the role of focused abdominal sonography in trauma (FAST) remains ill defined. The objective of this study was to assess the sensitivity and specificity of FAST for detecting free peritoneal fluid in children. The trauma registry of a single level I pediatric trauma center was queried for the results of FAST examination of consecutive pediatric (blunt trauma patients over a period of 36 months, from January 2010 to December 2012. Demographics, type of injuries, FAST results, computerized tomography (CT) results, and operative findings were reviewed. During the study period, 543 injured pediatric patients (mean age 8.2 ± 5 years) underwent FAST examinations. In 95 (17.5 %) FAST was positive for free peritoneal fluid. CT examination was performed in 219 (40.3 %) children. Positive FAST examination was confirmed by CT scan in 61/73 (83.6 %). CT detected intra-peritoneal fluid in 62/448 (13.8 %) of the patients with negative FAST results. These findings correspond to a sensitivity of 50 %, specificity of 88 %, positive predictive value (PPV) of 84 %, and a negative predictive value (NPV) of 58 %. In patients who had negative FAST results and no CT examination (302), no missed abdominal injury was detected on clinical ground. FAST examination in the young age group (tool to discriminate injured children in need of further imaging evaluation.

  3. Transcranial Doppler sonography in children: Review of a seven-year experience

    International Nuclear Information System (INIS)

    Hirsch, Wolfgang; Hiebsch, Wolfgang; Teichler, Heike; SchlUeter, Andreas

    2002-01-01

    AIM: We report the use of transcranial Doppler sonography (TCD) examinations in children (mean age 12.7 years; range 0.5-18 years) without an open fontanelle, using TCD equipment with a 2 MHz pulse wave transducer. Our results over a 7-year period are described. MATERIAL AND METHODS: A total of 858 children were referred from the paediatric outpatient department. All patients were divided into three groups according to the reason for referral. RESULTS: We found positive pathological results in the following: (1) headache and orthostatic dysregulation (0.4%, three out of 728); (2) acute neurological symptoms (5.4%, six out of 112); (3) other indications (22.2%, four out of 18). The positive predictive value of finding an abnormality was very low (0.50) . CONCLUSION: TCD examination is ineffective in children with non-specific headache or orthostatic dysregulation due to the specific limitations of this method. We found a higher percentage of abnormal results in children referred for other indications. However, since these children usually undergo MR imaging (and MR angiography, if necessary), in our opinion the TCD examination does not add any additional information. The value of TCD in children is not in the primary diagnosis of disease but in the follow up of known vascular processes (e.g. stenoses) or in chronic diseases including angiitis and sickle cell disease. Hirsch, W. et al. (2002)

  4. Deep vein thrombosis of lower extremity: What is the most important finding in duplex Doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Koh, Byung Hee; Cho, On Koo; Rhim, Hyun Chul; Seo, Heung Suk; Hahm, Chang Kok; Kwak, Jin Young [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1993-12-15

    The positive findings of deep vein thrombosis on duplex Doppler ultrasonography such as intraluminal clot,non-compressibility of the venous lumen and abnormal or absent Doppler shift signal are well known. However, relatively hypoechoic thrombus is not always seen in sonography, and the vein is frequently compressible in partial thrombosis. In order to evaluate the most common and important findings of deep vein thrombosis, we analysed the findings at duplex Doppler ultrasound in 19 patients and compared the results with those of contrast venography in 11 patients. Duplex Doppler ultrasound examination of the common femoral and popliteal veins was performed for one extremity in 14 patients, and for both extremities in 5 (total 24 extremities). Contrast venography was performed for one extremity in 7 patients, and for both sides in 4 (total 15 extremities).Thrombosis was seen in 45.8%, non-compressibility of lumen in 75%, absent or decreased Doppler signal from common femoral vein in 95.8%. Thrombosis was seen in 41.7%, non-compressibility of lumen in 70.8%, absent or decreased Doppler shift signal from popliteal vein in 95.8%. We conclude that abnormal or absent Doppler shift signal is the most sensitive and important finding of the deep vein thrombosis

  5. The B-mode Sonography and Sonoelastographic Features of Sclerosing Adenosis of the Breast

    International Nuclear Information System (INIS)

    Myong, Joo Hwa; Kim, Sung Hun; Kang, Bong Joo; Ahn, Young I; Yoon, Soo Kyoung; Lee, A Won; Yim, Kwang Il; Kim, Tae Eun; Song, Byung Joo

    2011-01-01

    The purpose of this study was to evaluate the B-mode sonographic and sonoelastographic features of high risk lesions of the breast. From April 2009 to February 2010, 1390 patients with breast lesions underwent US-guided core-biopsy. Among them, 13 lesions were confirmed to be pure sclerosing adenosis by subsequent surgical excision or on imaging follow-up of more than 1 year. Two radiologists retrospectively analyzed the B-mode sonography according to the Breast Imaging Reporting and Data System classification. The sonoelastographic images were classified into 5 elasticity scores according to the Itoh classification and the strain ratio between the mass and the surrounding fat tissue was reviewed. We considered the sonoelastographic patterns to be suspicious for the case with a score of 4 and 5 and a strain ratio of more than a 2.24. The common B-mode sonographic features of sclerosing adenosis were an irregular shape (69.2%, 9 of 13), an indistinct margin (92.3%, 12 of 13), hypoechogenicity (76.9%, 10 of 13) and category 4A, a low suspicion of malignancy (61.5%, 8 of 13). The common sonoelastographic features were a score of 2 (42%, 6 of 13) and a strain ratio < 2.24 (69.2%, 9 of 13). Sclerosing adenosis showed suspicious B-mode sonographic findings, but it had benign sonolastographic features

  6. The B-mode Sonography and Sonoelastographic Features of Sclerosing Adenosis of the Breast

    Energy Technology Data Exchange (ETDEWEB)

    Myong, Joo Hwa; Kim, Sung Hun; Kang, Bong Joo; Ahn, Young I; Yoon, Soo Kyoung; Lee, A Won; Yim, Kwang Il; Kim, Tae Eun; Song, Byung Joo [Seoul St. Mary' s Hospital, The Catholic University, Seoul (Korea, Republic of)

    2011-06-15

    The purpose of this study was to evaluate the B-mode sonographic and sonoelastographic features of high risk lesions of the breast. From April 2009 to February 2010, 1390 patients with breast lesions underwent US-guided core-biopsy. Among them, 13 lesions were confirmed to be pure sclerosing adenosis by subsequent surgical excision or on imaging follow-up of more than 1 year. Two radiologists retrospectively analyzed the B-mode sonography according to the Breast Imaging Reporting and Data System classification. The sonoelastographic images were classified into 5 elasticity scores according to the Itoh classification and the strain ratio between the mass and the surrounding fat tissue was reviewed. We considered the sonoelastographic patterns to be suspicious for the case with a score of 4 and 5 and a strain ratio of more than a 2.24. The common B-mode sonographic features of sclerosing adenosis were an irregular shape (69.2%, 9 of 13), an indistinct margin (92.3%, 12 of 13), hypoechogenicity (76.9%, 10 of 13) and category 4A, a low suspicion of malignancy (61.5%, 8 of 13). The common sonoelastographic features were a score of 2 (42%, 6 of 13) and a strain ratio < 2.24 (69.2%, 9 of 13). Sclerosing adenosis showed suspicious B-mode sonographic findings, but it had benign sonolastographic features

  7. Sonography of suspected acute appendicitis in children: Evaluation of the progress in performance of senior residents.

    Science.gov (United States)

    Gerbier, Pierre; Binet, Aurélien; Etancelin, Mathilde; Barteau, Emmanuel; Auger, Marie; Morales, Luciano; Bertrand, Philippe; Sirinelli, Dominique; Morel, Baptiste

    2018-04-01

    The objective of this study was to evaluate the progress in performance of senior residents in diagnosing acute appendicitis. Results were collected and compared of ultrasound examinations performed for suspected acute appendicitis by three senior residents and two faculty members over a six-month period in a university hospital setting. A grid with the sonographic findings was completed separately by the residents and the faculty members immediately after each examination. The duration of each examination was reported. The final ultrasound diagnosis was compared to the surgical and pathological results and to the clinical follow-up. The residents and faculty members performed 171 consecutive ultrasound examinations including 49 children with acute appendicitis and 122 with normal appendices. The accuracy of the diagnosis by the residents was 96%, and was similar to that of the faculty members (kappa=0.90) over the six months. The duration of the resident ultrasound examinations was significantly shorter during the second three-month period (p=0.01). No significant differences in diagnostic accuracy were demonstrated by the residents between the first and second three-month periods (p=0.06). The residents performed well when using sonography to diagnose acute appendicitis in children, and were faster during the second three-month period. I. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Childhood acute pyelonephritis: comparison of power Doppler sonography and Tc-DMSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Stogianni, Aggeliki; Oikonomou, Ippoliti; Dimitriadis, Athanasios [Aristotle University of Thessaloniki, Department of Radiology, AHEPA Hospital, Thessaloniki (Greece); Nikolopoulos, Panagiotis [424 Army Hospital, Department of Radiology, Thessaloniki (Greece); Gatzola, Magdalini [Aristotle University of Thessaloniki, 2nd Paediatric Clinic, AHEPA Hospital, Thessaloniki (Greece); Balaris, Vassilios [Aristotle University of Thessaloniki, Department of Nuclear Medicine, AHEPA Hospital, Thessaloniki (Greece); Farmakiotis, Dimitrios [Infectious Diseases Hospital of Thessaloniki, Department of Medicine, Thessaloniki (Greece)

    2007-07-15

    Tc 99m DMSA scintigraphy is regarded as the gold standard for the detection and localization of acute pyelonephritis (APN) in children. Power Doppler sonography (PD US) is a radiation-free and cost-effective technique that could be useful in the diagnosis of APN in children. To compare the predictive value of PD US with DMSA scintigraphy in the diagnosis of APN in children. A total of 74 neonates and children with clinical findings consistent with possible upper urinary tract infection were evaluated with PD US and DMSA scintigraphy. Children with anatomic (grey-scale) abnormalities were excluded. A total of 147 kidneys were examined within the first 48 h after the onset of symptoms. Each kidney was divided into three zones (upper, middle, and lower third). APN was diagnosed by PD US in 46 kidneys. Sensitivity and specificity for detecting APN using DMSA scintigraphy as the reference standard were 73.8% and 85.7%, respectively. There was good agreement between PD US and DMSA scintigraphy in the localization of lesions. In clinically suspected APN, PD US has acceptable specificity and sensitivity, if performed within the first 48 h and could be helpful in neonates and children under 3 months of age in whom the use of scintigraphy is generally discouraged. (orig.)

  9. Dynamic contrast-enhanced MRI and sonography in patients receiving primary chemotherapy for breast cancer

    International Nuclear Information System (INIS)

    Montemurro, Filippo; Aglietta, Massimo; Martincich, Laura; Rosa, Giovanni De; Cirillo, Stefano; Marra, Vincenzo; Regge, Daniele; Biglia, Nicoletta; Sismondi, Piero; Gatti, Marco

    2005-01-01

    We compared dynamic contrast-enhanced MRI (DCE-MRI) and sonography (US) for monitoring tumour size in 21 patients with breast cancer undergoing primary chemotherapy (PCT) followed by surgery. The correlation between DCE-MRI and US measurements of tumour size, defined as the product of the two major diameters, was 0.555 (P=0.009), 0.782 (P 2 , P 2 , P=0.009). After PCT, the median tumour size measured by the two techniques was similar (256 vs 289 mm 2 for DCE-MRI and US, respectively, P=0.859). The correlation with the histopathological major tumour diameter was 0.824 (P<0.001) and 0.705 (P<0.001) for post-treatment DCE-MRI and US, respectively. Measurements of the final major tumour diameter by DCE-MRI tended to be more precise, including cases achieving a pathological complete response. Randomized trials are warranted to establish the clinical impact of the initial discrepancy in tumour size estimates between DCE-MRI and US, and the trend towards a better definition of the final tumour size provided by DCE-MRI in this clinical setting. (orig.)

  10. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  11. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  12. Real-time virtual sonography for navigation during targeted prostate biopsy using magnetic resonance imaging data

    International Nuclear Information System (INIS)

    Miyagawa, Tomoaki; Ishikawa, Satoru; Kimura, Tomokazu; Suetomi, Takahiro; Tsutsumi, Masakazu; Irie, Toshiyuki; Kondoh, Masanao; Mitake, Tsuyoshi

    2010-01-01

    The objective of this study was to evaluate the effectiveness of the medical navigation technique, namely, Real-time Virtual Sonography (RVS), for targeted prostate biopsy. Eighty-five patients with suspected prostate cancer lesions using magnetic resonance imaging (MRI) were included in this study. All selected patients had at least one negative result on the previous transrectal biopsies. The acquired MRI volume data were loaded onto a personal computer installed with RVS software, which registers the volumes between MRI and real-time ultrasound data for real-time display. The registered MRI images were displayed adjacent to the ultrasonographic sagittal image on the same computer monitor. The suspected lesions on T2-weighted images were marked with a red circle. At first suspected lesions were biopsied transperineally under real-time navigation with RVS and then followed by the conventional transrectal and transperineal biopsy under spinal anesthesia. The median age of the patients was 69 years (56-84 years), and the prostate-specific antigen level and prostate volume were 9.9 ng/mL (4.0-34.2) and 37.2 mL (18-141), respectively. Prostate cancer was detected in 52 patients (61%). The biopsy specimens obtained using RVS revealed 45/52 patients (87%) positive for prostate cancer. A total of 192 biopsy cores were obtained using RVS. Sixty-two of these (32%) were positive for prostate cancer, whereas conventional random biopsy revealed cancer only in 75/833 (9%) cores (P<0.01). Targeted prostate biopsy with RVS is very effective to diagnose lesions detected with MRI. This technique only requires additional computer and RVS software and thus is cost-effective. Therefore, RVS-guided prostate biopsy has great potential for better management of prostate cancer patients. (author)

  13. Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography.

    Science.gov (United States)

    Bunegin, L; Wahl, D; Albin, M S

    1994-03-01

    Cerebral embolism has been implicated in the development of cognitive and neurological deficits following bypass surgery. This study proposes methodology for estimating cerebral air embolus volume using transcranial Doppler sonography. Transcranial Doppler audio signals of air bubbles in the middle cerebral artery obtained from in vivo experiments were subjected to a fast-Fourier transform analysis. Audio segments when no air was present as well as artifact resulting from electrocautery and sensor movement were also subjected to fast-Fourier transform analysis. Spectra were compared, and frequency and power differences were noted and used for development of audio band-pass filters for isolation of frequencies associated with air emboli. In a bench model of the middle cerebral artery circulation, repetitive injections of various air volumes between 0.5 and 500 microL were made. Transcranial Doppler audio output was band-pass filtered, acquired digitally, then subjected to a fast-Fourier transform power spectrum analysis and power spectrum integration. A linear least-squares correlation was performed on the data. Fast-Fourier transform analysis of audio segments indicated that frequencies between 250 and 500 Hz are consistently dominant in the spectrum when air emboli are present. Background frequencies appear to be below 240 Hz, and artifact resulting from sensor movement and electrocautery appears to be below 300 Hz. Data from the middle cerebral artery model filtered through a 307- to 450-Hz band-pass filter yielded a linear relation between emboli volume and the integrated value of the power spectrum near 40 microL. Detection of emboli less than 0.5 microL was inconsistent, and embolus volumes greater than 40 microL were indistinguishable from one another. The preliminary technique described in this study may represent a starting point from which automated detection and volume estimation of cerebral emboli might be approached.

  14. Sonography of injury of the ulnar collateral ligament of the elbow - initial experience

    International Nuclear Information System (INIS)

    Miller, Theodore T.; Adler, Ronald S.; Friedman, Lawrence

    2004-01-01

    The purpose of this study is to describe the sonographic appearance of injuries of the ulnar collateral ligament (UCL) of the elbow. Eight non-professional male baseball pitchers, ages 13-35 years, with medial elbow pain and clinical suspicion of ulnar collateral ligament injury, were referred for imaging. All eight underwent sonography of the affected and contralateral asymptomatic elbow, and six also underwent MR imaging. Neither valgus stress nor power Doppler was used during the sonographic examinations. Time from onset of symptoms to imaging was 1.5 weeks to 6 months. Three patients had surgical confirmation of their injuries, with time from imaging to surgery of 2 days to 9 months. In four patients, the UCL was ruptured, manifest sonographically in three cases as discontinuity of the normally hyperechoic ligament with anechoic fluid in the gap and in one case as non-visualization of the ligament with heterogeneous echogenicity in the expected location of the ligament. Two adolescent patients had avulsions of the UCL from the medial epicondyle, with sonographic demonstration of the avulsed echogenic bony fragment in both cases. One patient had a mild sprain, manifest as mild thickening and decreased echogenicity of the ligament sonographically compared with the contralateral normal elbow, with mild surrounding hypoechoic edema. The eighth patient had a small partial tear of the deep surface of the distal aspect of the ligament, visualized as a hypoechoic focus between the deep surface of the ligament and its ulnar attachment. Tears of the ulnar collateral ligament are manifested sonographically as non-visualization of the ligament or alteration of the normal morphology. (orig.)

  15. Association between two distinct executive tasks in schizophrenia: a functional transcranial Doppler sonography study

    Directory of Open Access Journals (Sweden)

    Theodoridou Anastasia

    2006-05-01

    Full Text Available Abstract Background Schizophrenia is a severe mental disorder involving impairments in executive functioning, which are important cognitive processes that can be assessed by planning tasks such as the Stockings of Cambridge (SOC, and tasks of rule learning/abstraction such as the Wisconsin Card Sorting Test (WCST. We undertook this study to investigate the association between performance during separate phases of SOC and WCST, including mean cerebral blood flow velocity (MFV measurements in chronic schizophrenia. Methods Functional transcranial Doppler sonography (fTCD was used to assess bilateral MFV changes in the middle (MCA and anterior (ACA cerebral arteries. Twenty-two patients with chronic schizophrenia and 20 healthy subjects with similar sociodemographic characteristics performed SOC and WCST during fTCD measurements of the MCA and the ACA. The SOC was varied in terms of easy and difficult problems, and also in terms of separate phases, namely mental planning and movement execution. The WCST performance was assessed separately for maintaining set and set shifting. This allowed us to examine the impact of problem difficulty and the impact of separate phases of a planning task on distinct intervals of WCST. Simultaneous registration of MFV was carried out to investigate the linkage of brain perfusion during the tasks. Results In patients, slowing of movement execution during easy problems (SOC was associated with slowing during maintaining set (WCST (P Conclusion The results of this study demonstrate performance and brain perfusion abnormalities in the association pattern of two different tasks of executive functioning in schizophrenia, and they support the notion that executive functions have a pathological functional correlate predominantly in the lateral hemispheres of the brain. This study also underpins the scientific potential of fTCD in assessing brain perfusion in patients with schizophrenia.

  16. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  17. Use of Hysterosalpingo-Foam Sonography for Assessment of the Efficacy of Essure Hysteroscopic Sterilization.

    Science.gov (United States)

    Rosič, Maja; Žegura, Branka; Vadnjal Đonlagić, Sabina

    2018-01-18

    Hysterosalpingo-foam sonography (HyFoSy) has been suggested to be a possible less invasive alternative to hysterosalpingography (HSG), which is the reference standard for confirmation of tubal occlusion after Essure (Bayer AG, Leverkusen, Germany) hysteroscopic sterilization. The purpose of our study was to evaluate the accuracy of HyFoSy compared to HSG for confirmation of tubal occlusion after Essure hysteroscopic sterilization. A prospective study included 90 patients who underwent Essure hysteroscopic sterilization. Twelve weeks after the sterilization, 2-dimensional transvaginal ultrasonography was performed to assess the microinsert position and was followed by HyFoSy and HSG for evaluation of tubal occlusion. Patients with patent fallopian tubes on HSG were scheduled for additional HSG procedures at 3-month intervals until tubal occlusion was documented. Of 90 enrolled patients, 86 patients with 170 fallopian tubes underwent the complete imaging protocol. Tubal occlusion was evaluated by HyFoSy as an index test and HSG as a reference standard. The accuracy of HyFoSy was 97.1% (95% confidence interval [CI], 93%-99%). The sensitivity and specificity were 100% (95% CI, 97%-100%) and 54.6% (95% CI, 23%-83%), whereas the positive and negative predictive values were 97.0% (95% CI, 93%-99%) and 100% (95% CI, 42%-100%), respectively. No long-term complications were reported for HyFoSy or HSG. Given that the concordance rate for tubal occlusion between HyFoSy and HSG was not 100%, an occluded fallopian tube on HyFoSy should be confirmed by HSG, which remains the reference standard for confirmation of tubal occlusion after Essure hysteroscopic sterilization. © 2018 by the American Institute of Ultrasound in Medicine.

  18. Sonography of the painful shoulder: role of the operator's experience

    Energy Technology Data Exchange (ETDEWEB)

    Corroller, Thomas Le; Cohen, Michel; Champsaur, Pierre [Hopital Sainte-Marguerite, Service d' Imagerie Medicale, Marseille (France); Aswad, Richard [Clinique Juge, Service de Chirurgie Orthopedique, Marseille (France); Pauly, Vanessa [Hopital Sainte-Marguerite, D.I.M., Marseille (France)

    2008-11-15

    The aim of our study was to determine the role of the operator's experience in the sonographic evaluation of the painful shoulder and to validate assumptions about its technical performance in routine practice. Two radiologists, respectively standard and expert sonographic operators, independently and prospectively scanned 65 patients with clinical suspicion of rotator cuff lesion. Magnetic resonance arthrography was the reference standard. The sensitivity of the expert ultrasound operator was 95.3% for full-thickness rotator cuff tears (41/43), 70.6% for partial-thickness tears (12/17), 64.3% for intratendinous tears (9/14), 100% for abnormality of the long head of biceps tendon (seven of seven), 88.9% for supraspinatus tendinosis (16/18), 96.4% for subacromial bursa abnormalities (53/55), and 91.7%for acromioclavicular joint osteoarthritis (33/36). The two sonographic operators were in very good agreement about full-thickness rotator cuff tears ({kappa}=0.90), supraspinatus tendinosis ({kappa} =0.80), abnormalities of the long head of biceps tendon ({kappa}=0.84), subacromial bursa abnormalities ({kappa}=0.89), and acromioclavicular osteoarthritis ({kappa}=0.81). The agreement was only moderate for partial-thickness tears ({kappa}=0.63) and intratendinous tears ({kappa}=0.57). Our results show that in moderately experienced hands as in experts' hands, sonography has a low level of interobserver variability for full-thickness rotator cuff tears. Considering partial-thickness and intratendinous rotator cuff tears, our data suggest that interobserver variability is higher. (orig.)

  19. Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?

    Science.gov (United States)

    Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul

    2012-01-01

    BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.

  20. Renal transplantation: Sonography and Doppler assessment of transplanted kidneys in adult Sudanese patients

    Directory of Open Access Journals (Sweden)

    Moawia Gameraddin

    2017-06-01

    Full Text Available Background Every year, thirty-five thousand patients receive renal transplants worldwide. Kidney transplant provides better quality of life and reduced morbidity. Doppler and sonography were the best imaging modalities for evaluation. Aims To assess the sonographic findings of renal allograft and to determine the correlation between Doppler resistive index and size of allograft and echogenicity. Methods This was a cross-sectional study conducted in Khartoum State from January to August 2016. A total of 86 patients with known transplanted kidneys were scanned with ultrasound using 3MHz and 5MHz transducers. The age was categorized into four groups and so the Doppler indices. Descriptive statistics used to analyse quantitative and qualitative variables (percent and means ± SD. Spearman's rho test was used to find the correlation between RI of renal vessels and allograft size. The Qui-square test was used to find an association between RI and echogenicity of the graft. Results Renal transplantation was common at the age of 20 to 50 years. The mean Doppler index of the renal artery was 0.68±0.11 in renal allografts. Renal transplantation was common in professionals and homemakers (30.2 per cent and 20.93 per cent respectively. Hypertension and diabetes were the most common causes (44.1 per cent and 18.6 per cent. A significant correlation was found between RI and allograft size (p-value=0.012. There was no statistical association between RI and echogenicity of allograft (pvalue=0.106. Conclusion The Doppler resistive index is significantly correlated with allograft size and had no association with echogenicity. Patients with enlarged allograft had raised resistive indices. The study recommended that Duplex ultrasound should be used in the initial assessment and follow-up of renal transplant.

  1. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H.J.; Platsch, G.; Wolf, F. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Nuclear Medicine; Guenter, E.; Becker, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 1; Rupprecht, H.; Neumayer, H.H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 4

    1997-08-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [Deutsch] Ziel der Studie war es, das

  2. A novel decision tree approach based on transcranial Doppler sonography to screen for blunt cervical vascular injuries.

    Science.gov (United States)

    Purvis, Dianna; Aldaghlas, Tayseer; Trickey, Amber W; Rizzo, Anne; Sikdar, Siddhartha

    2013-06-01

    Early detection and treatment of blunt cervical vascular injuries prevent adverse neurologic sequelae. Current screening criteria can miss up to 22% of these injuries. The study objective was to investigate bedside transcranial Doppler sonography for detecting blunt cervical vascular injuries in trauma patients using a novel decision tree approach. This prospective pilot study was conducted at a level I trauma center. Patients undergoing computed tomographic angiography for suspected blunt cervical vascular injuries were studied with transcranial Doppler sonography. Extracranial and intracranial vasculatures were examined with a portable power M-mode transcranial Doppler unit. The middle cerebral artery mean flow velocity, pulsatility index, and their asymmetries were used to quantify flow patterns and develop an injury decision tree screening protocol. Student t tests validated associations between injuries and transcranial Doppler predictive measures. We evaluated 27 trauma patients with 13 injuries. Single vertebral artery injuries were most common (38.5%), followed by single internal carotid artery injuries (30%). Compared to patients without injuries, mean flow velocity asymmetry was higher for single internal carotid artery (P = .003) and single vertebral artery (P = .004) injuries. Similarly, pulsatility index asymmetry was higher in single internal carotid artery (P = .015) and single vertebral artery (P = .042) injuries, whereas the lowest pulsatility index was elevated for bilateral vertebral artery injuries (P = .006). The decision tree yielded 92% specificity, 93% sensitivity, and 93% correct classifications. In this pilot feasibility study, transcranial Doppler measures were significantly associated with the blunt cervical vascular injury status, suggesting that transcranial Doppler sonography might be a viable bedside screening tool for trauma. Patient-specific hemodynamic information from transcranial Doppler assessment has the potential to alter

  3. Cystic degeneration of the tibial nerve. Magnetic resonance neurography and sonography appearances of an intraneural ganglion cyst

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio Silveira, Claudio Regis [Sao Carlos Imaging/Sao Carlos Hospital, Musculoskeletal Imaging Division, Fortaleza, CE (Brazil); Maia Vieira, Clarissa Gadelha; Machado Pereira, Brenda [Sao Carlos Imaging/Sao Carlos Hospital, Fortaleza, CE (Brazil); Pinto Neto, Luiz Holanda [Articular Clinic, Fortaleza, CE (Brazil); Chhabra, Avneesh [UT Southwestern, Radiology and Orthopaedic Surgery, Dallas, TX (United States)

    2017-12-15

    Extra- and intraneural ganglion cysts have been described in the literature. The tibial nerve ganglion is uncommon and its occurrence without intra-articular extension is atypical. The pathogenesis of cystic degeneration localized to connective and perineural tissue secondary to chronic mechanical irritation or idiopathic mucoid degeneration is hypothesized. Since the above pathology is extremely rare and the magnetic resonance imaging examination detects the defining characteristics of the intrinsic alterations of the tibial nerve, the authors illustrate such a case of tibial intaneural ganglion cyst with its magnetic resonance neurography and sonography appearances. (orig.)

  4. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara; Puglisi, Fabio; Di Loreto, Carla

    2004-01-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  5. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Londero, Viviana; Bazzocchi, Massimo; Del Frate, Chiara; Francescutti, Giuliana; Zuiani, Chiara [Institute of Radiology, University of Udine, via Colugna 50, 33100, Udine (Italy); Puglisi, Fabio [Department of Oncology, University of Udine, via Colugna 50, 33100, Udine (Italy); Di Loreto, Carla [Institute of Pathology, University of Udine, via Colugna 50, 33100, Udine (Italy)

    2004-08-01

    The accuracy of mammography, sonography and magnetic resonance imaging (MRI) in identifying residual disease after neoadjuvant chemotherapy is evaluated and imaging findings are correlated with pathologic findings. Fifteen patients enrolled in an experimental protocol of preoperative neoadjuvant chemotherapy underwent clinical examination, mammography, sonography and dynamic MRI, performed in this order, before and respectively after 2 and 4 cycles of neoadjuvant chemotherapy. Four radiologists, two for mammography, one for sonography and one for MR, examined the images, blinded to the results of the other examinations. All patients underwent radical or conservative surgery, and imaging findings were compared with pathologic findings. MRI identified 2/15 (13.3.%) clinically complete response (CR), 9/15 (60%) partial response (PR), 3/15 (20%) stable disease (SD) and 1/15 (6.7%) progressive disease. Mammography identified 1/15 (6.7%) clinically CR, 8/15 (53.3%) PR and 4/15 (27%) SD, and was not able to evaluate the disease in 2/15 (13%) cases. Sonography presented the same results as MRI. Therefore, MRI and sonography compared to mammography correctly identified residual disease in 100 vs. 86%. MRI resulted in two false-negative results because of the presence of microfoci of in situ ductal carcinoma (DCIS) and invasive lobular carcinoma (LCI). MRI was superior to mammography in cases of multifocal or multicentric disease (83 vs. 33%). Sonography performed after MRI improves the accuracy in evaluation of uncertain foci of multifocal disease seen on MR images with an increase of diagnostic accuracy from 73 to 84.5%. MRI assesses response to neoadjuvant chemotherapy better than traditional methods of physical examination and mammography. (orig.)

  6. Comparison of findings of spontaneous splenorenal shunt in color Doppler sonography with multislice CT scan (64 slices) in liver transplant candidates

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Mohammadhadi, E-mail: Bagherimh@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hajati, Azadeh, E-mail: azadeh.hajati@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Hosseini, Mohammadkazem, E-mail: hosseiniaslm@sums.ac.ir [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of); Ostad, Seyed Pouria, E-mail: Pouria.Ostad@gmail.com [Department of Radiology, Shiraz University of Medical Sciences, Namazi Hospital, Shiraz (Iran, Islamic Republic of)

    2012-09-15

    Background: Liver transplantation is the only definite treatment for end stage liver disease and it has high costs for the medical system so decreasing its complication and increasing its effectiveness is crucial. One of the factors that affect liver transplantation is the presence of spontaneous splenorenal shunt. Its diagnosis is mainly overlooked in pre-liver transplant patients. Main modality for its diagnosis is multislice CT scan however this is more expensive than sonography. Also, it exposes the patients to ionizing radiation. Considering the advantages of color Doppler ultrasound, studies to determine the sensitivity and specificity for detection of spontaneous splenorenal shunt is essential. Materials and methods: In our study 70 cirrhotic patients who were referred by liver transplant surgeons for evaluation of abdomen by CT and sonograhy were assessed for presence of spontaneous splenorenal shunt, left adrenal varix and left renal vein diameter and velocity and sensitivity and specificity of both modalities were checked. Patients in whom left renal vein could not evaluated by sonography and patients with splenectomy and nutcracker syndrome were excluded. Results: In the point of 10 mm diameter of left renal vein in CT scan there was 78.6% sensitivity and 67.9% specificity for the presence of spontaneous splenorenal shunt. Left adrenal varix in CT had sensitivity of 71.4%, specificity of 100%, and positive predictive value of 100% and negative predictive value of 70% and varix below spleen in CT had sensitivity of 54.8%, specificity of 96.4%, and positive predictive value of 95.8% and negative predictive value of 58.7% for the presence of spontaneous splenorenal shunt. In the point of 8 mm diameter of left renal vein in sonography there was 66.7% sensitivity and 85.7% specificity for the presence of spontaneous splenorenal shunt. For the velocity of more than 35 cm/s of left renal vein in sonography there was 61.9% sensitivity and 82.1% specificity for

  7. Does ultrasound contrast agent improve the diagnostic value of colour and power Doppler sonography in superficial lymph node enlargement?

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Demharter, Johannes; Linne, Renate; Droste, Dirk W.; Bohndorf, Klaus; Buecklein, Wolfgang

    2003-01-01

    Objective: to analyse whether ultrasound contrast agent (UCA) improves the diagnostic accuracy to differentiate between benign and malignant superficial lymph node enlargement by using colour-coded duplex sonography (CCDS) and power Doppler (PD). Methods: 32 patients with suspected malignant superficial lymph node enlargement prospectively underwent standardised ultrasound examinations using B-mode sonography and native and contrast-enhanced CCDS and PD immediately before biopsy. Solbiati-Index (longitudinal-transverse diameter ratio) and intranodal flow patterns by using different vascularisation types were assessed. Histological and sonographical findings were correlated. Results: 27 malignant and 5 benign lymph nodes were found. Solbiati-Index was lower in malignant lymph nodes than in benign nodes (mean 1.5 vs. 2.4, P<0.045). More intranodal flow patterns could be detected after UCA (53 vs. 43) but the number of correctly identified malignant nodes decreased after UCA (26 vs. 24) and the number of correctly identified benign nodes remained constant compared with native CCDS and PD. In 31% of the colour-mode studies, PD was considered to visualise more clearly intranodal vascular flow patterns than CCDS. Conclusion: despite depicting more intranodal vascular patterns, the use of an ultrasound contrast agent seems not to improve the diagnostic value of CCDS and PD compared with native colour-mode studies in superficial lymph node enlargement

  8. Detection and monitoring of cerebral hemodynamic disturbances with transcranial color-coded duplex sonography in patients after head injury

    International Nuclear Information System (INIS)

    Kochanowicz, J.; Mariak, Z.; Lyson, T.; Lewko, J.; Krejza, J.; Bilello, M.

    2006-01-01

    Reduced cerebral blood flow after severe head injury results in an increased risk of ischemic brain damage. Blood flow should therefore be monitored with a simple, reliable method. Transcranial color-coded Doppler sonography (TCCS) is an accepted tool for the diagnosis of cerebral vasospasm; however, its usefulness in evaluating patients with head injury has not been proven. Cerebral blood-flow velocity in the middle, anterior, and posterior cerebral arteries was measured with a 2.5 MHz probe (Aplio SSA 770A, Toshiba, Japan) in 36 subjects with moderate or severe head injury. Serial measurements of resistance index (RI), peak-systolic, end-diastolic, and mean velocity in the middle cerebral arteries were performed 2-24 h after head trauma and in the subsequent days during hospitalization. Immediately after head trauma, increased RI values, and unusually decreased blood-flow velocity (mainly in MCA) were observed. Microcirculation disturbances were suspected because the end-diastolic velocity had substantially diminished. Changes in blood-flow parameters correlated with the clinical state, and in most cases, a poor prognosis. In some patients, blood-flow velocity increased above the normal reference limit and this implied poor prognosis. Transcranial color-coded Doppler sonography is a reliable, repeatable, and accessible tool that provides information about cerebral blood-flow disturbances and may hold diagnostic and prognostic importance. (orig.)

  9. Renal vein doppler sonography in rabbits with acute ureteral obstruction: usefulness of impedance index of renal vein

    International Nuclear Information System (INIS)

    Sohn, Kyung Myung; Chung, Su Kyo; Lee, Sung Yong

    2004-01-01

    To evaluate the usefulness of the impedance index of the renal vein for the diagnosis of acute obstructive uropathy in rabbits. Ligation of the left ureter was done in 12 rabbits. Doppler sonography of the interlobar veins in both kidneys was checked before and 30 minutes, 1, 3, 6, 9 and 24 hours after ureteral ligation. The venous impedance index [(peak flow signal-least flow signal)/peak flow signal] was compared between the obstructed and non-obstructed kidneys for all periods. The change in the impedance index after ureteral ligation was also compared between the obstructed and non-obstructed kidneys. A decrease in the impedance index of the intrarenal vein was observed starting from 30 mins atter ureteral ligation, and the index remained low up to 24 hours after ureteral ligation. The obstructed kidneys had a significantly lower impedance index than the contralateral kidneys for all six of the postligation measurements (p< 0.05). There were significant differences in the change of impedance index after ureteral ligation between the obstructed and non-obstructed kidneys (p< 0.05). The impedance index of the intrarenal vein was significantly decreased in the obstructed kidneys. The measurement of the impedance index of the intrarenal vein using Doppler sonography could provide a useful method of diagnosing obstructive uropathy

  10. Sonography and hypotension: a change to critical problem solving in undergraduate medical education

    Directory of Open Access Journals (Sweden)

    Amini R

    2016-01-01

    Full Text Available Richard Amini, Lori A Stolz, Nicholas C Hernandez, Kevin Gaskin, Nicola Baker, Arthur Barry Sanders, Srikar AdhikariDepartment of Emergency Medicine, University of Arizona Medical Center, College of Medicine, University of Arizona, Tucson, AZ, USAStudy objectives: Multiple curricula have been designed to teach medical students the basics of ultrasound; however, few focus on critical problem-solving. The objective of this study is to determine whether a theme-based ultrasound teaching session, dedicated to the use of ultrasound in the management of the hypotensive patient, can impact medical students’ ultrasound education and provide critical problem-solving exercises.Methods: This was a cross-sectional study using an innovative approach to train 3rd year medical students during a 1-day ultrasound training session. The students received a 1-hour didactic session on basic ultrasound physics and knobology and were also provided with YouTube hyperlinks, and links to smart phone educational applications, which demonstrated a variety of bedside ultrasound techniques. In small group sessions, students learned how to evaluate patients for pathology associated with hypotension. A knowledge assessment questionnaire was administered at the end of the session and again 3 months later. Student knowledge was also assessed using different clinical scenarios with multiple-choice questions.Results: One hundred and three 3rd year medical students participated in this study. Appropriate type of ultrasound was selected and accurate diagnosis was made in different hypotension clinical scenarios: pulmonary embolism, 81% (95% CI, 73%–89%; abdominal aortic aneurysm, 100%; and pneumothorax, 89% (95% CI, 82%–95%. The average confidence level in performing ultrasound-guided central line placement was 7/10, focused assessment with sonography for trauma was 8/10, inferior vena cava assessment was 8/10, evaluation for abdominal aortic aneurysm was 8/10, assessment for

  11. Sonography and hypotension: a change to critical problem solving in undergraduate medical education.

    Science.gov (United States)

    Amini, Richard; Stolz, Lori A; Hernandez, Nicholas C; Gaskin, Kevin; Baker, Nicola; Sanders, Arthur Barry; Adhikari, Srikar

    2016-01-01

    Multiple curricula have been designed to teach medical students the basics of ultrasound; however, few focus on critical problem-solving. The objective of this study is to determine whether a theme-based ultrasound teaching session, dedicated to the use of ultrasound in the management of the hypotensive patient, can impact medical students' ultrasound education and provide critical problem-solving exercises. This was a cross-sectional study using an innovative approach to train 3rd year medical students during a 1-day ultrasound training session. The students received a 1-hour didactic session on basic ultrasound physics and knobology and were also provided with YouTube hyperlinks, and links to smart phone educational applications, which demonstrated a variety of bedside ultrasound techniques. In small group sessions, students learned how to evaluate patients for pathology associated with hypotension. A knowledge assessment questionnaire was administered at the end of the session and again 3 months later. Student knowledge was also assessed using different clinical scenarios with multiple-choice questions. One hundred and three 3rd year medical students participated in this study. Appropriate type of ultrasound was selected and accurate diagnosis was made in different hypotension clinical scenarios: pulmonary embolism, 81% (95% CI, 73%-89%); abdominal aortic aneurysm, 100%; and pneumothorax, 89% (95% CI, 82%-95%). The average confidence level in performing ultrasound-guided central line placement was 7/10, focused assessment with sonography for trauma was 8/10, inferior vena cava assessment was 8/10, evaluation for abdominal aortic aneurysm was 8/10, assessment for deep vein thrombus was 8/10, and cardiac ultrasound for contractility and overall function was 7/10. Student performance in the knowledge assessment portion of the questionnaire was an average of 74% (SD =11%) at the end of workshop and 74% (SD =12%) 3 months later (P=0.00). At our institution, we

  12. Assessment of follow-up sonography and clinical improvement among infants with congenital muscular torticollis.

    Science.gov (United States)

    Park, H-J; Kim, S S; Lee, S-Y; Lee, Y-T; Yoon, K; Chung, E-C; Rho, M-H; Kwag, H-J

    2013-04-01

    Infants grow rapidly, which causes the SCM to thicken physiologically. Therefore some cases of physiologically-thickened SCM can be confused with a poor response to physical therapy. There have been only a few quantitative ultrasonographic studies on the clinical outcome of rehabilitation for CMT. Our aim was to evaluate whether a new sonographic assessment method that uses the muscular thickness ratio of the SCM can help quantify the outcome of rehabilitation therapy for patients with CMT. We evaluated 48 patients (male/female, 17:31; mean age, 3.9 months) who were diagnosed with CMT and who underwent initial and follow-up sonography. The ratio of the thickness of the involved SCM to the thickness of the intact SCM (SCM thickness ratio) was calculated. A scoring system based on the range of motion of the neck was used to assess clinical improvement. The correlations between clinical improvement and the thickness of the involved muscle, the difference in involved muscle thickness, the SCM thickness ratio, and the difference in the SCM thickness ratio were evaluated with Spearman rank correlations. Follow-up Cheng scores were higher than initial scores; this difference indicates clinical resolution (follow-up, 4.90; initial, 3.38). The SCM thickness ratio at follow-up was lower than that at the initial evaluation (follow-up, 1.29-1.34; initial, 1.65-1.77). Intra- and interobserver agreements were excellent. Most variables were moderately correlated with clinical improvement (correlation coefficients, 0.36-0.509). R1 showed the highest correlation with clinical improvement (0.481 and 0.509), followed by the initial maximal thickness of the SCM (0.434 and 0.488). ΔP (P1-P2) and ΔR showed similar correlation coefficients with clinical improvement. Measurement of the SCM thickness ratio appears to overcome the problem of a false-positive diagnosis of clinical aggravation of CMT resulting from physiologic growth. R1 and ΔR are accurate objective measurements, which

  13. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol

    2003-01-01

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 ± 39.7 ml/min for the right side and 127.6 ± 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 ± 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 ± 59.19 ml/min in male, and 217.28 ± 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  14. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma

    NARCIS (Netherlands)

    Tummers, W.; Schuppen, J.V. (J Van); H.R. Langeveld-Benders (Hester); Wilde, J.; Banderker, E.; Van, A.

    2016-01-01

    textabstractBackground: The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed

  15. Fusiform-shaped nodules along the internal carotid artery demonstrated by follow-up sonography within the dissected neck area in patients with oral cancer

    International Nuclear Information System (INIS)

    Hayashi, Takafumi; Katsura, Kouji; Taira, Shuhzou; Shingaki, Susumu; Hoshina, Hideyuki

    2004-01-01

    In order to distinguish benign from malignant nodules within the dissected neck area in patients with oral cancer during the follow-up period, we retrospectively evaluated the frequency and characteristic findings of fusiform-shaped nodules along the internal carotid artery observed by follow-up sonography. From 1997 to 2003, 52 patients with oral cancer, who underwent radical neck dissections, were enrolled in this study. The study cohort consisted of 33 males and 19 females ranging in age from 29 to 84 years (mean, 62.0 years). After neck dissection, every patient was examined repeatedly with sonography during the follow-up period at an interval of one month. CT and/or MRI were performed when clinically required. Any patient with recurrent neck mass was excluded from this study. In the 52 patients, fusiform-shaped nodules were observed in 10 patients (19%) by the follow-up sonography. The nodules were homogenously hypoechoic and the margin was well-demarcated except for the upper end. A hyperechoic core was clearly observed in every nodule, which showed a fatty density on post-contrast CT. On post-contrast MRI, the nodules enhanced markedly and the core showed hypointensity on fat saturated images. In conclusion, it was suggested that the fusiform-shaped nodules observed by follow-up sonography within the dissected neck area might be the superior cervical ganglion of sympathetic trunk. However, further studies are needed to disclose the true character of the nodules. (author)

  16. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma

    NARCIS (Netherlands)

    Tummers, W.; van Schuppen, J.; Langeveld, H.; Wilde, J.; Banderker, E.; van As, A.

    2016-01-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical

  17. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  18. Sonography-guided hydrostatic reduction of ileocolic intussusception in children: analysis of failure and success in consecutive patients presenting timely to the hospital.

    Science.gov (United States)

    Menke, Jan; Kahl, Fritz

    2015-03-01

    In children with ileocolic intussusception sonography is increasingly being used for diagnosis, whereas fluoroscopy is frequently used for guiding non-invasive reduction. This study assessed the success rate of radiation-free sonography-guided hydrostatic reduction in children with ileocolic intussusception, using novel well-defined success rate indices. All children were evaluated who presented from 2005 to 2013 to the local university hospital with ileocolic intussusception. The patients were treated with sonography-guided hydrostatic reduction unless primary surgery was clinically indicated. The according success rate was determined by indices of Bekdash et al. They represent the ratio of persistently successful non-surgical reductions versus four different denominators, depending on including/excluding cases with primary surgery and including/excluding cases requiring bowel resection/intervention. Fifty-six consecutive patients were included (age, 3 months to 7.8 years). About 80% of the patients presented until 24 h and 20% until 48 h after the onset of symptoms. Seven patients underwent primary surgery, with bowel resection required in three cases. Hydrostatic reduction was attempted in 49 patients, being permanently successful in 41 cases (selective reduction rate 41/49 = 83.7%; crude reduction rate 41/56 = 73.2%). The remaining eight patients underwent secondary surgery, with just two patients not requiring surgical bowel resection/intervention (corrected selective reduction rate 41/43 = 95.3%). The composite reduction rate was 87.2% (successful/feasible reductions, 41/47). Radiation-free sonography-guided hydrostatic reduction has a good success rate in children with ileocolic intussusception. It may be particularly valuable in centers that are already experienced with using sonography for the diagnosis.

  19. Does color Doppler sonography improve the clinical assessment of patients with acute scrotum?

    International Nuclear Information System (INIS)

    Pepe, Pietro; Panella, Paolo; Pennisi, Michele; Aragona, Francesco

    2006-01-01

    Introduction and objectives: Our experience concerning the use of color Doppler sonography (CDS) in the differential diagnosis of acute scrotum is reported. Material and methods: From July 2000 to July 2005, 155 patients (median 17.2 years) were admitted with a diagnosis of acute scrotum (unilateral in 150 cases, bilateral in 5). Along with a careful anamnesis and the physical exam, all patients underwent a CDS study of the scrotal content using a sonograph GE Logiq 500 with a multifrequency (7.5-10 MHz) linear probe Small Part. The following CDS parameters were evaluated: intensity of the color-power signal on the testicular parenchyma and on the epididymis; systolic peak velocity (SPV) and telediastolic velocity (TDV) in correspondence of the gonadal hilum. Ultrasound and flowmetry parameters registered on the painful testis were compared with those registered on the healthy controlateral testis. The reduction/absence versus the increase of color-power signal in the parenchyma and the reduction/absence versus the increase of SPV and TDV in the centripetal intratesticular arteries were considered presumptive of testicular torsion versus orchiepididymitis. Results: The results only refer to the 150 patients (300 testis) with acute monolateral scrotum. The clinical picture and the physical exam suggested a torsion of the spermatic cord in 40 cases, a spontaneous de-torsion in 5, an orchiepididymitis in 80, a blunt scrotal trauma in 15, a bulky epididymal cyst or a hydrocele in 4 and a testicular pain of unknown etiology in the remaining 6 cases. Standard US was pathological in 95 patients (63.3%); CDS was pathologic in 70 patients and in 42 of them suggested a testicular torsion. Fifty-three patients underwent surgical exploration: among 42 patients with a presumptive diagnosis of testicular torsion, the diagnosis was confirmed in 22 cases, no anomaly was found in 16 cases and in 4 patients a torsion of testicular appendix was found. The rupture of the tunica

  20. Intravenous contrast-enhanced sonography in children and adolescents – a single center experience

    Directory of Open Access Journals (Sweden)

    Martin Stenzel

    2013-06-01

    from B mode and color coded sonography. Overall, most examinations were done to assess the liver (n=16, followed by the kidney in 10 cases. The different etiologies were encountered in the following order: tumor (n=22, infection (n=9, trauma (n=5, ischemia (n=4. Most examinations were performed to evaluate a hepatic lesion (n=12. There was one incident recorded that fit the criteria of a possible adverse effect. In an 8-year-old girl nausea was noted, that started 15 minutes after the end of the examination and resolved spontaneously. In none of the patients medical treatment for adverse effects was necessary. Conclusion: Ultrasonography in children, enhanced by intravenous use of contrast medium is feasible and allows for further evaluating cystic and solid tumors, and organ perfusion. Given that proper medical equipment and correct ultrasound machine settings are used, it is a robust method without diagnostic failures. In this small-sized case series there were no severe adverse effects, however, off-label use in children needs to be addressed.

  1. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients; Wertigkeit der Mamma-MRT als Ergaenzung zu Mammographie und Sonographie bei Patientinnen mit erhoehtem Mammakarzinomrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2008-04-15

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [German] Ziele der Arbeit sind die inhaltliche Einfuehrung in das Thema Frueherkennung des Mammakarzinoms bei Patientinnen mit erhoehtem Risiko und eine systematische Analyse der Wertigkeit von MRT und anderen bildgebenden Verfahren in diesem Zusammenhang. Es wurde eine systematische Literaturrecherche ueber die letzten 3 Jahre durchgefuehrt. Dabei wurden Vergleichsstudien der verschiedenen bildgebenden Verfahren in der Mammadiagnostik beruecksichtigt, bei denen die bildgesteuerte Biopsie als Goldstandard angegeben wurde. Von allen bildgebenden Verfahren zeigt die Mamma-MRT bei Patientinnen mit familiaerem Risiko die hoechste Sensitivitaet und diagnostische Genauigkeit bei der Detektion des Mammakarzinoms. Fuer MRT, Mammographie und Sonographie werden Sensitivitaeten zwischen 71 und 100%, 0 und 78% sowie 13 und 65% angegeben. Die Mamma-MRT ist ein etabliertes Verfahren zum Screening von Risikopatientinnen. Uebereinstimmend wird der diagnostische Nutzen der Mamma-MRT als ergaenzendes Verfahren zu Mammographie

  2. Transvaginal sonography combined with saline contrast sonohysterography in evaluating the uterine cavity in premenopausal patients with abnormal uterine bleeding

    DEFF Research Database (Denmark)

    Dueholm, M; Forman, A; Jensen, ML

    2001-01-01

    OBJECTIVES: To evaluate whether saline contrast sonohysterography (SCSH) adds additional information to that obtained by transvaginal sonography (TVS) for predicting endometrial abnormality in premenopausal patients with abnormal uterine bleeding. PATIENTS AND METHODS: This was a two......-center prospective study at a university clinic and a central hospital in Denmark. The uterine cavity was evaluated with TVS and SCSH in 470 premenopausal patients with abnormal uterine bleeding. One hundred and eighty-nine of the patients had operative hysteroscopy or hysterectomy within 4 months which provided...... uterine bleeding. All abnormalities except one were found at SCSH, while TVS alone missed polyps and had almost one in four equivocal findings. The use of TVS, without saline contrast, left one in five of the polyps undiagnosed in referred patients with abnormal bleeding....

  3. Narrowing of the middle cerebral artery: artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD.

    Science.gov (United States)

    Swiercz, Miroslaw; Swiat, Maciej; Pawlak, Mikolaj; Weigele, John; Tarasewicz, Roman; Sobolewski, Andrzej; Hurst, Robert W; Mariak, Zenon D; Melhem, Elias R; Krejza, Jaroslaw

    2010-01-01

    The goal of the study was to compare performances of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of the middle cerebral artery (MCA) narrowing in the same population of patients using statistical and nonstatistical intelligent models for data analysis. We prospectively collected data from 179 consecutive routine digital subtraction angiography (DSA) procedures performed in 111 patients (mean age 54.17+/-14.4 years; 59 women, 52 men) who underwent TCD and TCCS examinations simultaneously. Each patient was examined independently using both ultrasound techniques, 267 M1 segments of MCA were assessed and narrowings were classified as 50% lumen reduction. Diagnostic performance was estimated by two statistical and two artificial neural networks (ANN) classification methods. Separate models were constructed for the TCD and TCCS sonographic data, as well as for detection of "any narrowing" and "severe narrowing" of the MCA. Input for each classifier consisted of the peak-systolic, mean and end-diastolic velocities measured with each sonographic method; the output was MCA narrowing. Arterial narrowings less or equal 50% of lumen reduction were found in 55 and >50% narrowings in 26 out of 267 arteries, as indicated by DSA. In the category of "any narrowing" the rate of correct assignment by all models was 82% to 83% for TCCS and 79% to 81% for TCD. In the diagnosis of >50% narrowing the overall classification accuracy remained in the range of 89% to 90% for TCCS data and 90% to 91% for TCD data. For the diagnosis of any narrowing, the sensitivity of the TCCS was significantly higher than that of the TCD, while for diagnosis of >50% MCA narrowing, sensitivity of the TCCS was similar to sensitivity of the TCD. Our study showed that TCCS outperforms conventional TCD in detection of diagnosis of >50% MCA narrowing. (E-mail: jaroslaw.krejza@uphs.upenn.edu).

  4. Hysterosalpingo-foam sonography (HyFoSy): Tolerability, safety and the occurrence of pregnancy post-procedure.

    Science.gov (United States)

    Tanaka, Keisuke; Chua, Jackie; Cincotta, Robert; Ballard, Emma L; Duncombe, Gregory

    2018-02-01

    Fallopian tube patency testing is an essential part of infertility evaluation. Hysterosalpingo-contrast sonography (HyCoSy) has been described as reliable, well tolerated and safe compared to other modalities such as laparoscopy and a dye test or hysterosalpingography. Limited availability of the previously used contrast has led to the introduction of a foam contrast agent as an alternative. To assess the tolerability, safety and occurrence of pregnancy post-procedure of hysterosalpingo-foam sonography (HyFoSy). A retrospective cohort study of women who had a HyFoSy at Queensland Ultrasound for Women from March 2013 to February 2015. A questionnaire was sent to their referring doctor to identify any complications or subsequent pregnancies with or without artificial reproductive technology (ART) within six months of the HyFoSy. Of 200 women, four cases were abandoned due to difficulty introducing the intracervical catheter, severe discomfort or a vasovagal episode. Response from referring doctors for 155 women reported no post-procedural complication. One hundred and eleven women were followed up for at least six months. Twenty-four out of 59 women (40.7%) who had ART and 24 out of 52 women (46.2%) who did not have ART conceived. Fifty percent of women who were nulligravida at the time of investigation, found to have at least one patent fallopian tube, whose partner had a normal semen analysis, spontaneously conceived within the time of follow up. HyFoSy is well tolerated and safe. A preponderance of pregnancies in the first month after HyFoSy suggests that a therapeutic effect may exist. © 2017 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  5. The value of high-resolution sonography and MR imaging in the diagnosis and follow-up of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Buchberger, W.; Judmaier, W.; Birbamer, G.; Hasenoehrl, K.; Schmidauer, C.

    1993-01-01

    120 wrists of 105 patients with carpal tunnel syndrome were studied preoperatively by high-resolution sonography. Follow-up examinations after carpal tunnel release were performed in 72 wrists. In addition, 40 wrists were examined preoperatively, and 20 wrists were examined postoperatively by MR imaging. Based on quantitative analysis of the cross-sectional area and shape of the median nerve and of the palmar bowing of the flexor retinaculum, sonography established the diagnosis in 95% of cases. MR was superior in the evaluation of mild degrees of median nerve compression, and in the detection of possible causes of the carpal tunnel syndrome, such as synovitis of the flexor tendon sheaths or ganglionic cysts. In postoperative follow-up, sonographic demonstration of a normally flattened median nerve was an excellent indicator of the successful carpal tunnel release. In 10 patients with persistent or recurrent symptoms after carpal tunnel release, the underlying pathology could be exactly demonstrated by MR. (orig.) [de

  6. Diagnostic medical imaging systems. X-ray radiography and angiography, computerized tomography, nuclear medicine, NMR imaging, sonography, integrated image information systems. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Morneburg, H.

    1995-01-01

    This third edition is based on major review and updating work. Many recent developments have been included, as for instance novel systems for fluoroscopy and mammography, spiral CT and electron beam CT, nuclear medical tomography ( SPECT and PET), novel techniques for fast NMR imaging, spectral and colour coded duplex sonography, as well as a new chapter on integrated image information systems, including network installations. (orig.) [de

  7. Comparing Effects of Medication Therapy and Exercise Training with Diet on Liver enzyme Levels and Liver Sonography in Patients with Non-Alcoholic Fatty Liver Disease (NAFLD

    Directory of Open Access Journals (Sweden)

    Azadeh Nabizadeh Haghighi

    2016-03-01

    Full Text Available Background & Objectives: Non-alcoholic fatty liver disease, characterized by the deposition of fat in liver cells, can cause fibrosis, cirrhosis, and liver cell damage if not controlled. The aim of this study is to compare the effects of medication therapy and exercise training with diet on liver enzyme levels and liver sonography in patients with non-alcoholic fatty liver disease (NAFLD. Materials & Methods :In this quasi-experimental study, female patients with non-alcoholic fatty liver were randomly divided into two groups: medication therapy (n = 10 and exercise therapy (n = 10 for 8 weeks. During this period, the exercise group performed exercise training three days a week for 90 minutes per session. The drug was given to the medication group. In both groups, the diet was 500 calories less than their daily energy. Before and after intervention, blood tests and liver sonography were executed. All statistical analyses were done using SPSS for Windows version 20. Comparisons between and within groups were performed by Student's t-test and Wilcoxon test on paired and unpaired data. P < 0.05 was considered statistically significant. Results :In both groups, liver enzyme levels and disease severity in sonography reduced significantly (p<0.05. Conclusion: The findings of the present research showed that both methods of therapy have the same effect on reducing the severity of NAFLD.

  8. The utility of focused assessment with sonography for trauma as a triage tool in multiple-casualty incidents during the second Lebanon war.

    Science.gov (United States)

    Beck-Razi, Nira; Fischer, Doron; Michaelson, Moshe; Engel, Ahuva; Gaitini, Diana

    2007-09-01

    The purpose of this study was to evaluate the role of focused assessment with sonography for trauma (FAST) as a triage tool in multiple-casualty incidents (MCIs) for a single international conflict. The charts of 849 casualties that arrived at our level 1 trauma referral center were reviewed. Casualties were initially triaged according to the Injury Severity Score at the emergency department gate. Two-hundred eighty-one physically injured patients, 215 soldiers (76.5%) and 66 civilians (23.5%), were admitted. Focused assessment with sonography for trauma was performed in 102 casualties suspected to have an abdominal injury. Sixty-eight underwent computed tomography (CT); 12 underwent laparotomy; and 28 were kept under clinical observation alone. We compared FAST results against CT, laparotomy, and clinical observation records. Focused assessment with sonography for trauma results were positive in 17 casualties and negative in 85. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FAST were 75%, 97.6%, 88.2%, 94.1%, and 93.1%, respectively. A strong correlation between FAST and CT results, laparotomy, and clinical observation was obtained (P war conflict-related MCI, FAST enabled immediate triage of casualties to laparotomy, CT, or clinical observation. Because of its moderate sensitivity, a negative FAST result with strong clinical suspicion demands further evaluation, especially in an MCI.

  9. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.

  10. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    International Nuclear Information System (INIS)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok; Lee, Yeong Hwan

    1996-01-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm

  11. Sonographic findings predictive of central lymph node metastasis in patients with papillary thyroid carcinoma: influence of associated chronic lymphocytic thyroiditis on the diagnostic performance of sonography.

    Science.gov (United States)

    Yoo, Yeon Hwa; Kim, Jeong-Ah; Son, Eun Ju; Youk, Ji Hyun; Kwak, Jin Young; Kim, Eun-Kyung; Park, Cheong Soo

    2013-12-01

    To analyze sonographic findings suggesting central lymph node metastasis of papillary thyroid carcinoma and to evaluate the influence of associated chronic lymphocytic thyroiditis on the diagnostic performance of sonography for predicting central lymph node metastasis. A total of 124 patients (101 female and 23 male; mean age, 47.5 years; range, 21-74 years) underwent sonographically guided fine-needle aspiration in central lymph nodes from January 2008 to July 2011. Sonographic features of size, shape, margin, thickening of the cortex, cortical echogenicity, presence of a hilum, cystic changes, calcification, and vascularity of enlarged lymph nodes were analyzed before fine-needle aspiration and classified into 2 categories (probably benign and suspicious). Sonographic findings were correlated with the pathologic diagnosis and associated chronic lymphocytic thyroiditis. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance of sonography for predicting central lymph node metastasis according to the associated thyroiditis. Fifty-one lymph nodes (39.5%) were malignant, and 73 (60.5%) were benign. On univariate analysis, size, shape, margin, cortical thickening, cortical echogenicity, cystic changes, calcification, and vascularity were significantly different between the benign and metastatic nodes (P thyroiditis-positive patients and 0.971 (95% CI, 0.938-1.000) in negative patients. Eccentric cortical thickening and cortical hyperechogenicity were the sonographic findings predictive of central lymph node metastasis from papillary thyroid carcinoma. The diagnostic performance of sonography for predicting metastasis was superior in chronic lymphocytic thyroiditis-negative patients than in positive patients.

  12. Detection of Congenital Mullerian Anomalies Using Real-Time 3D Sonography

    Directory of Open Access Journals (Sweden)

    Firoozeh Ahmadi

    2011-01-01

    Full Text Available A 35 year-old woman referred to Royan Institute (Reproductive Biomedicine Research Center for infertilitytreatment. She had an eleven-year history of primary infertility with a normal abdominal ultrasound.Hysterosalpingography (HSG was obtained one month prior to referral in another center (Fig A.The HSG finding of an apparent unicorn uterus followed by a normal vaginal ultrasound led us toperform a three-dimensional vaginal ultrasound before resorting to hysteroscopy. Results of thethree-dimensional vaginal ultrasound revealed a normal uterus (Fig B, C.Accurate characterization of congenital Mullerian anomalies (MDAs such as an arcuate, unicornuate,didelphys, bicornuate or septate uterus is challenging. While HSG has been the standard test in the diagnosisof MDAs, some limitations may favor the use of three-dimensional ultrasound. The most difficult partof HSG is interpreting the two-dimensional radiographic image into a complex, three-dimensional livingorgan (1. A variety of technical problems may occur while performing HSG. In this case, only an obliqueview could lead to a correct interpretation. It is advisable for the interpreter to perform the procedure ratherthan to inspect only the finished radiographic images (2.One of the most useful scan planes obtained on three-dimensional ultrasound is the coronal view ofthe uterus. This view is known to be a valuable problem-solving tool that assists in differentiatingbetween various types of MDAs due to the high level of agreement between three-dimensionalultrasound and HSG (3, 4.Recently, three-dimensional ultrasound has become the sole mandatory step in the initial investigationof MDAs due to its superiority to other techniques that have been used for the same purpose (5.

  13. Correlation of computed tomography, sonography, and gross anatomy of the liver

    International Nuclear Information System (INIS)

    Sexton, C.F.; Zeman, R.K.

    1983-01-01

    Although the vascular and segmental anatomy of the liver is well defined in the sonographic and computed tomographic (CT) literature, the three-dimensional relations of hepatic structures remain conceptually complex. As an aid to understanding and teaching this anatomy, axially and sagitally sectioned gross liver specimens were correlated with appropriate sonographic and CT scans. Major hepatic landmarks and vascular structures are used to identify four distinct transverse planes and four sagittal planes

  14. Value of Perfusion CT, Transcranial Doppler Sonography, and Neurological Examination to Detect Delayed Vasospasm after Aneurysmal Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kunze, E.; Raslan, F.; Stetter, Ch.; Lee, J.Y.; Solymosi, L.; Ernestus, R.I.; Vince, G.H.; Westermaier, Th.; Pham, M.; Solymosi, L.

    2012-01-01

    Background. If detected in time, delayed cerebral vasospasm after aneurysmal subarachnoid hemorrhage (SAH) may be treated by balloon angioplasty or chemical vasospasmolysis in order to enhance cerebral blood flow (CBF) and protect the brain from ischemic damage. This study was conceived to compare the diagnostic accuracy of detailed neurological examination, Transcranial Doppler Sonography (TCD), and Perfusion-CT (PCT) to detect angiographic vasospasm. Methods. The sensitivity, specificity, positive and negative predictive values of delayed ischemic neurological deterioration (DIND), pathological findings on PCT-maps, and accelerations of the mean flow velocity (MVF) were calculated. Results. The accuracy of DIND to predict angiographic vasospasm was 0.88. An acceleration of MFV in TCD (>140 cm/s) had an accuracy of 0.64, positive PCT-findings of 0.69 with a higher sensitivity, and negative predictive value than TCD. Interpretation. Neurological assessment at close intervals is the most sensitive and specific parameter for cerebral vasospasm. PCT has a higher accuracy, sensitivity and negative predictive value than TCD. If detailed neurological evaluation is possible, it should be the leading parameter in the management and treatment decisions. If patients are not amenable to detailed neurological examination, PCT at regular intervals is a helpful tool to diagnose secondary vasospasm after aneurysmal SAH

  15. Transcranial sonography as a diagnostic tool for Parkinson's disease: a pilot study in the city of Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Rita de Cássia Leite Fernandes

    2011-12-01

    Full Text Available In Brazil there is no systematic study on Transcranial Sonography (TCS, a neuroimaging method that depicts echogenic deep brain structures using ultrasound. OBJECTIVE: To establish the percentage of subjects with permissive temporal windows and to address the ability of TCS of the substantia nigra (SN to distinguish parkinsonian patients in a Brazilian sample. METHOD: We performed TCS using the Acuson X300 (Siemens, Germany in 37 individuals: 23 with Parkinson's disease (PD and 14 healthy controls. RESULTS: 10.8% of subjects had insufficient temporal acoustic bone windows. SN echogenic areas were larger in patients (mean±SD, 0.31±0.08cm² compared to controls (mean±SD, 0.17±0.02cm². TCS accurately identified 88.2% of PD patients. CONCLUSION: A large proportion of Brazilians seem to be eligible for TCS. An expressive number of PD patients could be diagnosed by TCS based on an expanded SN echogenic area. However, the current data is preliminary and must be corroborated by larger studies.

  16. Transcranial doppler sonography in two patients who underwent decompressive craniectomy for traumatic brain swelling: report of two cases

    Directory of Open Access Journals (Sweden)

    Bor-Seng-Shu Edson

    2004-01-01

    Full Text Available The role of decompressive craniectomy in the treatment of severe posttraumatic cerebral swelling remains quite a controversial issue. To the best of our knowledge, there is no study demonstrating the effect of decompressive craniectomy on cerebral blood flow (CBF velocity by means of transcranial Doppler sonography (TCD. We present two patients who developed traumatic brain swelling and uncontrollable intracranial hypertension with coma and signs of transtentorial herniation. One patient underwent bifrontal, while the second, unilateral, frontotemporoparietal decompressive craniectomy with dural expansion. In both patients, TCD examinations were performed immediately before and after surgery to study the cerebral hemodynamic changes related to the operations. Pre and postoperative TCD examinations demonstrated a significant increase in blood flow velocity in the intracranial arteries in both subjects. In conclusion, our cases suggest that decompressive craniectomy with dural expansion may result in elevation of CBF velocity in patients with massive brain swelling. The increase in CBF velocity appears to occur not only in the decompressed hemisphere, but also on the opposite side.

  17. SELECTIVE AND NONSELECTIVE β-BLOCKERS IN PRIMARY OPEN ANGLE GLAUCOMA THERAPY – RESULTS OF COLOR DOPPLER SONOGRAPHY

    Directory of Open Access Journals (Sweden)

    Vukoslava Maričić-Došen

    2002-12-01

    Full Text Available Background. Primary open angle glaucoma (POAG is a syndrome of progressive optic neuropathy characterized by optic nerve head excavation and visual field defects. Poor correlation between IOP and progression of glaucoma disease sets vascular mechanism in the centre of attention. By Color Doppler sonography, quantification of blood flow changes in vessels, which supply optic nerve head, is possible. We wanted to find out whether there are changes in the circulation of central retinal artery and posterior ciliary arteries in patients with primary open angle glaucoma treated with selective or nonselective β -blockers.Methods. 44 patients (88 eyes were divided into two groups: group 1: 22 patients (44 eyes treated with selective β -blockers (Betaxolol 0.5% and group 2: 22 patients (44 eyes treated with nonselective β -blockers (Timolol 0.5%. Vascular indices (RI, PI were measured in the central retinal artery and posterior ciliary arteries.Results. We found decreased blood flow and increased vascular indices in both groups of patients, statistically significant difference between group 1 and group 2: blood flow velocity was higher and vascular indices were lower in group 1 (Betaxolol 0.5% compared to group 2 (Timolol 0..5%.Conclusions. Selective β -blockers (calcium channel blockers act more vasoactively and neuroprotectively comparing to nonselective β -blockers.

  18. Corpus luteum blood flow in normal and abnormal early pregnancy: evaluation and analysis with transvaginal color and pulsed doppler sonography

    International Nuclear Information System (INIS)

    Tang Xiaoyi; Lin Meifang; Zheng Meirong; Liang Xiaoxian; Liu Jianfeng

    2005-01-01

    Objective: Detecting and assessment the corpus luteum blood flow in normal and abnormal early pregnancy. Methods: Using transvaginal color and pulse Doppler sonography, we detected 215 pregnant women including 150 normal intrauterine pregnancies, 25 abortion, 29 ectopic pregnancies, and then recorded corpus luteum blood flow feature and the blood flow indexes (Vmax, RI and PI). Results: 1) Corpus luteum was successfully identified in 148 cases out of 150 of normal early pregnancies, 25 cases out of 26 of threatened abortion; 22 cases out of 29 of ectopic pregnancy. 2) Three groups shared the same feature of Color Doppler imaging: a circumferential rim around the entire corpus luteum. 3) The flow index revealed mean PVS, RI and PI had no statistical difference in normal and abnormal early pregnancy; The mean PVS was lower in ectopic pregnancy than in normal pregnancy (P<0.05), while PI and PR had no characteristic in ectopic pregnancy group compared with the indexes obtained in normal pregnancy group. Conclusion: The corpus luteum can be precisely identified in most pregnancy using transvaginal color Doppler and manifests a characterized rim Doppler imaging. PVS may help in differentiating the ectopic pregnancy from normal early pregnancy. (authors)

  19. TRANSVAGINAL SONOGRAPHY COMBINED WITH SALINE CONTRAST SONOHYSTEROGRAPHY IN EVALUATING THE UTERINE CAVITY IN PREMENOPAUSAL PATIENTS WITH ABNORMAL UTERINE BLEEDING

    Directory of Open Access Journals (Sweden)

    K. G. M. Premleel

    2016-06-01

    Full Text Available OBJECTIVES To evaluate whether saline contrast sonohysterography (SCSH improved the diagnostic accuracy of transvaginal sonography (TVS for predicting endometrial abnormality in premenopausal patients with abnormal uterine bleeding. PATIENTS AND METHODS The uterine cavity was evaluated with TVS and SCSH in 60 premenopausal patients with abnormal uterine bleeding. All 58 patients underwent operative hysteroscopy or hysterectomy within 4 months which provided a detailed description of the uterine cavity and was used as the true value for exclusion of polyps and submucous myomas. RESULT Out of 60 patients, 45 had uterine abnormalities on TVS and SCSH and rest of the patients who appeared normal but had other abnormalities such as ovarian haemorrhagic cyst. Out of the 45 patients, 9 patients had submucous myomas and 9 were diagnosed as endometrial polyp. The findings were confirmed using hysterectomy/hysteroscopy/endometrial sampling. CONCLUSION The use of TVS without saline contrast left nine submucosal fibroids and five in nine of the polyps undiagnosed in referred patients with complaints of abnormal bleeding. It also helps in reducing the rate of more invasive procedures such as hysteroscopy. However, studies carried out for longer duration and large study population are required to validate our findings

  20. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  1. Comparison of Sensitivity & Specificity of Transvaginal Sonography, Saline Infusion Sonohysterography and Hysteroscopy in Evaluation of Women with Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    K Shojaie

    2009-10-01

    Full Text Available Introduction: Bleeding disorders are a common problem in daily practice, especially in premenopausal women. In our investigation, we compared the sensitivity and specificity of three different diagnostic methods Trans-vaginal sonography(TVS, saline infusion sonohystrography(SIS and Hysteroscopy. Methods: It was a cross- sectional study with a study population of ninety-nine women suffering fromAUB attending the outpatient clinic of Imam and Razi hospital in Ahvaz- Iran. They were evaluated by three different diagnostic methods and the results were compared. This study started from March 2008 to December 2008. The sensitivity, specificity, positive predictive and negative predictive values were measured in TVS, SIS, and finally these two methods were compared with hysteroscopy (as a gold standard. Results: The sensitivity and specificity of TVS was 74.2% and 49.7%, respectively, while that of SIS was 91.6% and 86%, respectively. The positive predictive value and negative predictive value of TVS was 71.9% and 54.3%, respectively, while that of SIS was 85.9% and 85.75%, respectively. The sensitivity, specificity, the positive predictive and negative predictive values of SIS was more than TVS, and it was similar to hysteroscopy. Conclusion: The findings obtained in the present study indicate that in AUB, sensitivity, specificity, positive and negative predictive value of SIS is more than TVS and therefore can be considered as a first step for diagnosis of AUB.

  2. Usefulness of High-Frequency Compound Spatial Sonography in the Assessment of Hepatitis B Virus Related Chronic Liver Disease

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Cha, Sang Hoon; Chung, Hwan Hoon; Lee, Ki Yeol; Kim, Baek Hyun; Kim, Kyung Ah; Kim, Yoon Hwan; Park, Cheol Min; Lee, Eung Seok; Byun, Kwan Soo

    2007-01-01

    To evaluate the liver parenchyma according to the echo patterns of CSS (compound spatial sonography), and to correlate them with the extent of hepatic fibrosis and the serum aminotransferase level. The CSS images were classified into the following three echo patterns: type I, a normal looking echo: type II, hyperechoic or hypoechoic nodules scattered in a normal-looking echo: type III, a severely heterogeneous echogenic or hypoechoic honeycomb-like echo. The CSS findings were correlated with the histopathology findings in 63 patients with HBV. The serum aminotransferase levels and the occurrence of acute exacerbation in 168 patients with HBV, with and without a progressed parenchymal echo pattern, and who were followed up more than 1-year period, were compared. The interobserver agreement between the two radiologists for assessing the parenchymal echo pattern was scored. The correlation between the CSS pattern and hepatic fibrosis was statistically significant (correlation coefficient = 0.58, p < 0.05). The baseline serum aminotransferase level was not significantly different between the patients with and without a progressed parenchymal echo pattern. However, the rate of acute exacerbation was higher in patients with a progressed parenchymal echo pattern (p < 0.05). The interobserver agreement was good (k statistic = 0.63, 0.78). The liver parenchymal pattern based on the 5-12 MHz CSS is a useful and objective tool for diagnosing and monitoring HBV related chronic liver disease

  3. Evaluation of sonography and CT in detecting lymph node metastases in malignancies of the head and neck

    International Nuclear Information System (INIS)

    Robatscher, P.A.S.

    2001-01-01

    Imaging methods are, compared to anamnesis and clinical investigation, of importance in the praetherapeutic diagnosis of head and neck tumors. Sonography and CT are used routinely in staging of the primary and in staging of the cervical lymph nodes. A MRI-investigation is possible, too. The main interest is concentrated upon the status of the lymph nodes, because it takes strong influence on the therapeutic management and of course on the prognosis. Methods: each lymph node level of the 203 patients with untreated head and neck tumors will be analyzed, if the staging procedure (imaging methods and histological examination) is complete. Further two statistical hypotheses are defined: 1. Lymph nodes, which are 'probably metastatic' are classed with the 'metastatic'. 2. In the second hypothesis the 'probably metastatic' nodes are counted with the 'unsuspicious' ones. Results: The sensitivity rate of US is 66,67 % and CT 30,16 %. The difference of specifity between these two methods is small (US: 87,1 %; CT: 96,13 %). The reason for the decrease of the sensitivity of US and CT (50,79 %/26.98 %) in the second hypothesis and the increase of the specifity (94,84 %/96,45 %) could be explained with the definition of the hypothesis. Therefore the number of false negative is higher. These results suggest that US versus CT is a more useful diagnostic tool in detecting cervical lymph node metastases. Hence the operative procedure should depend on the accurate diagnosis made by US. (author)

  4. [The cross-sectional area of the median nerve by sonography in the diagnosis of carpal tunnel syndrome].

    Science.gov (United States)

    Sabag-Ruiz, Enrique; Higuera-Lugo, Cirilo Omar; Ornelas-Aguirre, José Manuel; Gómez-Alcalá, Alejandro V

    2009-01-01

    To measure the median nerve cross-sectional area (MNCSA) at the carpal tunnel (CT) level by sonography (S) in a Mexican population. A comparative cross-sectional design study with a nonprobabilistic sampling with 50 women and 50 men in good health were submitted for measuring MNCSA at the level of the CT. Other variables like sex; side and degree of daily hand activity were also studied. The analysis was made by descriptive statistics, and Mann-Whitney U or Kruskal-Wallis tests. The mean MNCSA was 0.063 +/- 0.015 cm(2), in women; in men it was 0.072 +/- 0.018 cm(2); the difference was significant (p right side and 0.060 cm(2) in the left (90th percentile for both hands of 0.084 cm(2)); in men, it was of 0.070 cm(2) in the right hand and of 0.069 cm(2) in the left (90th percentile for both hands of 0.097 cm(2)). The difference between women and men was significant in each side, but not between right and left hands (p = 0.21). There was no correlation between age and MNCSA on either side, or with hand activity. A MNCSA value of 0.1 cm(2) for men and 0.09 cm(2) for women is proposed as a standard parameter for the Mexican population.

  5. Can routine trauma bay chest x-ray be bypassed with an extended focused assessment with sonography for trauma examination?

    Science.gov (United States)

    Soult, Michael C; Weireter, Leonard J; Britt, Rebecca C; Collins, Jay N; Novosel, Timothy J; Reed, Scott F; Britt, L D

    2015-04-01

    The objective of this study was to investigate the feasibility of using ultrasound (US) in place of portable chest x-ray (CXR) for the rapid detection of a traumatic pneumothorax (PTX) requiring urgent decompression in the trauma bay. All patients who presented as a trauma alert to a single institution from August 2011 to May 2012 underwent an extended focused assessment with sonography for trauma (FAST). The thoracic cavity was examined using four-view US imaging and were interpreted by a chief resident (Postgraduate Year 4) or attending staff. US results were compared with CXR and chest computed tomography (CT) scans, when obtained. The average age was 37.8 years and 68 per cent of the patients were male. Blunt injury occurred in 87 per cent and penetrating injury in 12 per cent of activations. US was able to predict the absence of PTX on CXR with a sensitivity of 93.8 per cent, specificity of 98 per cent, and a negative predictive value of 99.9 per cent compared with CXR. The only missed PTX seen on CXR was a small, low anterior, loculated PTX that was stable for transport to CT. The use of thoracic US during the FAST can rapidly and safely detect the absence of a clinically significant PTX. US can replace routine CXR obtained in the trauma bay and allow more rapid initiation of definitive imaging studies.

  6. A method for the automated assessment of temporal characteristics of functional hemispheric lateralization by transcranial Doppler sonography.

    Science.gov (United States)

    Deppe, M; Knecht, S; Lohmann, H; Ringelstein, E B

    2004-07-01

    Transcranial Doppler sonography (TCD) can guide and complement investigations based on functional magnetic resonance and positron emission tomography imaging by providing continuous information on cerebral perfusion changes correlated to cerebral activation. So far, however, the role of functional TCD has been limited by a lack of sensitivity. Here, the authors present an outline of a method that increases the potential of TCD to detect perfusion changes within a vascular territory. Sensitivity on the order of 1% can be achieved by transformation of Doppler envelope curves, which accounts for systemic quasi-periodic and irregular spontaneous blood flow modulations and artificial disturbances related to the recording. A statistical technique is introduced that allows the automatic detection of time periods of significant hemispheric lateralization in evoked flow studies. Furthermore, an index of laterality is defined quantifying the extent of hemispheric dominance during stimulus processing. The analysis technique described in this article has been successfully employed in recent examinations on vision, motor activation, language, language recovery, and other cognitive tasks. The novel functional TCD technique permits valid and reproducible assessments of the temporal characteristics of functional hemispheric lateralization.

  7. Utilização do FAST-Estendido (EFAST-Extended Focused Assessment with Sonography for Trauma em terapia intensiva Usefulness of Extended-FAST (EFAST-Extended Focused Assessment with Sonography for Trauma in critical care setting

    Directory of Open Access Journals (Sweden)

    Uri Adrian Prync Flato

    2010-09-01

    Full Text Available A principal causa de morte no Brasil, em pacientes com idade inferior a 45 anos, está relacionada ao trauma, sendo responsável por um terço das internações em unidades de terapia intensiva. Em virtude do crescente conhecimento e disponibilidade da ultrassonografia para o diagnóstico e monitoramento de lesões ameaçadoras à vida, como tamponamento cardíaco e ruptura de órgão sólido na cavidade abdominal com choque hemorrágico, foi desenvolvido um protocolo denominado FAST (Focused Assesment with Sonography for Trauma no ambiente de emergência e terapia intensiva. Esta tecnologia está ganhando adeptos por sua reprodutibilidade, ausência de exposição à radiação ao paciente e facilidade beira leito. Uma nova complementação a este protocolo, denominada FAST-Estendido, proporciona informações valiosas na condução desses pacientes, ampliando o diagnóstico de doenças antes reservadas à cavidade abdominal e pericárdica, conjuntamente com doenças localizadas na cavidade torácica, em busca de hemotórax, derrame pleural e pneumotórax. Devemos salientar que esta modalidade de exame complementar substitui a tomografia computadorizada e o lavado peritoneal diagnóstico, mas não o retardo de intervenções cirúrgicas. Sua avaliação criteriosa, conjuntamente com dados clínicos, deve nortear as condutas terapêuticas, principalmente em locais inóspitos e/ou com limitações de recursos, como pré-hospitalar, unidades de terapia intensiva em zonas de conflito armado, áreas rurais e/ou geograficamente distantes, nas quais não há disponibilidade de outros métodos de imagem.Trauma is the leading cause of death in people below 45 years-old in Brazil, and responsible for one third of all intensive care unit admissions. The increasing knowledge on ultrasound diagnosis methods and its availability for life-threatening injuries (such as cardiac tamponade and abdominal cavity solid organs rupture leading to hemorrhagic shock

  8. The value of sonography, CT and air enema for detection of complicated Meckel diverticulum in children with nonspecific clinical presentation

    International Nuclear Information System (INIS)

    Daneman, A.; Lobo, E.; Alton, D.J.; Shuckett, B.

    1998-01-01

    Background. Complicated Meckel diverticulum (MD) in children does not always present with painless rectal bleeding and its presentation can then produce a difficult diagnostic dilemma. In this clinical setting, sonography (US), CT or even air enema may be the first modality chosen to evaluate these children rather than the radionuclide Meckel scan (RNMS). Purpose. To assess the value of US, CT and air enema for detection of complicated MD. Materials and methods. Review of clinical, imaging, surgical and pathological findings in 64 children (55 males, 9 females) aged 4 days -14 years (mean = 3.7 years) with MD seen during an 8-year period, 1990-1997. Results. (a) In 33 patients with rectal bleeding, MD was detected on RNMS in 32. Ten of these 32 had other imaging studies, all of which were negative. (b) The other 31 patients, with varied clinical presentations, did not undergo RNMS. In these 31 and the 1 with a negative RNMS, 14 (44 %) had imaging features highly suggestive for the diagnosis of MD on US in all 14, on CT in 1, and on air enema in 3. The radiological spectrum of the inflamed, hemorrhagic MD is illustrated. Conclusion. The inflamed, hemorrhagic and the inverted, intussuscepted MD have a spectrum of features recognizable on US, CT and air enema. Some of these appearances are specific, others are not. Knowledge of and recognition of these features will facilitate detection of complicated MD in larger numbers of children presenting with symptoms other than the classic history of painless rectal bleeding and also in those with normal RNMS. (orig.)

  9. The Transcranial Doppler Sonography for Optimal Monitoring and Optimization of Cerebral Perfusion in Aortic Arch Surgery: A Case Series.

    Science.gov (United States)

    Ghazy, Tamer; Darwisch, Ayham; Schmidt, Torsten; Nguyen, Phong; Elmihy, Sohaila; Fajfrova, Zuzana; Zickmüller, Claudia; Matschke, Klaus; Kappert, Utz

    2017-06-16

    To analyze the feasibility and advantages of transcranial doppler sonography (TCD) for monitoring and optimization of selective cerebral perfusion (SCP) in aortic arch surgery. From April 2013 to April 2014, nine patients with extensive aortic pathology underwent surgery under moderate hypothermic cardiac arrest with unilateral antegrade SCP under TCD monitoring in our institution. Adequate sonographic window and visualization of circle of Willis were to be confirmed. Intraoperatively, a cerebral cross-filling of the contralateral cerebral arteries on the unilateral SCP was to be confirmed with TCD. If no cross-filling was confirmed, an optimization of the SCP was performed via increasing cerebral flow and increasing PCO2. If not successful, the SCP was to be switched to bilateral perfusion. Air bubble hits were recorded at the termination of SCP. A sonographic window was confirmed in all patients. Procedural success was 100%. The mean operative time was 298 ± 89 minutes. Adequate cross-filling was confirmed in 8 patients. In 1 patient, inadequate cross-filling was detected by TCD and an optimization of cerebral flow was necessary, which was successfully confirmed by TCD. There was no conversion to bilateral perfusion. Extensive air bubble hits were confirmed in 1 patient, who suffered a postoperative stroke. The 30-day mortality rate was 0. Conclusion: The TCD is feasible for cerebral perfusion monitoring in aortic surgery. It enables a confirmation of adequacy of cerebral perfusion strategy or the need for its optimization. Documentation of calcific or air-bubble hits might add insight into patients suffering postoperative neurological deficits.

  10. Can the anterior-posterior thigh diameter be used as an indicator for fetal age using two-dimensional sonography?

    International Nuclear Information System (INIS)

    Ismail, Saad Ramzi

    2008-01-01

    This study evaluated the usefulness and direct correlation of a simple new method of predicting fetal age by measurement of the anterior-posterior thigh diameter (APTD) in a normal 18 to 28 week pregnancies using two-dimensional sonography. Little published research exists in the area of fetal thigh biometry, specifically in the use of the anterior-posterior fetal thigh diameter (APTD). The only study I found was that of fetal thigh circumference. Continuing review of existing practices needs to be coupled with evaluation of alternate or additional methodology. Materials and methods: This was a quantitative prospective study of 55 patients in High Level General Hospital, Alberta, Canada. Anterior-posterior thigh diameters (APTD) were sonographically measured. The normal range for each week of pregnancy was determined five times for reliability. Results: Significant correlation was found between (APTD) and fetal age from simple line regression analysis, with 99.993% confidence intervals at each week from 18 to 28 weeks gestation. There was a correlation of 1 mm APTD per 1 week of fetal age. In addition R > 0.93, P < 0.001. The residual scatter plots confirmed the APTD validity. Conclusion: APTD is a reliable and valid method for assessing fetal age in a normal pregnancy and may be particularly useful when other parameters are unable to accurately predict fetal age. An accurate linear measurement of multiple fetal parameters allows a more complete profile of fetal growth and estimated date of delivery (EDD). APTD may also be useful in identifying fetal growth problems. All of the values of fetal age lie directly on the 'best-fit' regression line. Since the coefficient of determination (Rsq) is very high, this model is very effective

  11. Accuracy of Focused Assessment with Sonography for Trauma (FAST) in Blunt Trauma Abdomen-A Prospective Study.

    Science.gov (United States)

    Kumar, Subodh; Bansal, Virinder Kumar; Muduly, Dillip Kumar; Sharma, Pawan; Misra, Mahesh C; Chumber, Sunil; Singh, Saraman; Bhardwaj, D N

    2015-12-01

    Focused assessment with sonography for trauma (FAST) is a limited ultrasound examination, primarily aimed at the identification of the presence of free intraperitoneal or pericardial fluid. In the context of blunt trauma abdomen (BTA), free fluid is usually due to hemorrhage, bowel contents, or both; contributes towards the timely diagnosis of potentially life-threatening hemorrhage; and is a decision-making tool to help determine the need for further evaluation or operative intervention. Fifty patients with blunt trauma abdomen were evaluated prospectively with FAST. The findings of FAST were compared with contrast-enhanced computed tomography (CECT), laparotomy, and autopsy. Any free fluid in the abdomen was presumed to be hemoperitoneum. Sonographic findings of intra-abdominal free fluid were confirmed by CECT, laparotomy, or autopsy wherever indicated. In comparing with CECT scan, FAST had a sensitivity, specificity, and accuracy of 77.27, 100, and 79.16 %, respectively, in the detection of free fluid. When compared with surgical findings, it had a sensitivity, specificity, and accuracy of 94.44, 50, and 90 %, respectively. The sensitivity of FAST was 75 % in determining free fluid in patients who died when compared with autopsy findings. Overall sensitivity, specificity, and accuracy of FAST were 80.43, 75 and 80 %, respectively, for the detection of free fluid in the abdomen. From this study, we can safely conclude that FAST is a rapid, reliable, and feasible investigation in patients with BTA, and it can be performed easily, safely, and quickly in the emergency room with a reasonable sensitivity, specificity, and accuracy. It helps in the initial triage of patients for assessing the need for urgent surgery.

  12. Comparison of transvaginal sonography and double-contrast barium enema for diagnosing deep infiltrating endometriosis of the posterior compartment.

    Science.gov (United States)

    Savelli, L; Manuzzi, L; Coe, M; Mabrouk, M; Di Donato, N; Venturoli, S; Seracchioli, R

    2011-10-01

    To compare the diagnostic accuracy of transvaginal sonography (TVS) and double-contrast barium enema (DCBE) in the preoperative detection of deep infiltrating endometriosis (DIE) of the posterior compartment. This was a prospective study of 69 consecutive patients with results of pelvic examination or symptoms suggestive of DIE of the posterior compartment. TVS and DCBE were performed before surgery by two groups of physicians specialized in endometriosis, each blinded to the results of the other technique. Imaging data were compared with histopathologic analysis of the resected specimen (gold standard). Sensitivity, specificity, positive and negative predictive values and test accuracies were calculated for both imaging modalities. Sixty seven of the 69 women had a nodule of DIE confirmed at laparoscopy and histopathologic examination. TVS diagnosed DIE in 57 (85%) of these patients, while DCBE revealed the presence of the lesion in 24 (36%) women. For the diagnosis of posterior DIE, TVS and DCBE had, respectively, a sensitivity of 85% and 36%, specificity of 100% and 100%, positive predictive value of 100% and 100%, negative predictive value of 17% and 4% and accuracy of 85.5% and 38%. In patients with pure bowel DIE the sensitivity was 91% and 43%, specificity was 100% and 100%, positive predictive value was 100% and 100%, negative predictive value was 29% and 6% and accuracy was 91% and 45%, respectively. TVS has a much higher sensitivity than does DCBE in detecting the presence of posterior DIE and should thus be regarded as the imaging modality of choice when there is clinical suspicion of the disease. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  13. The Posterior Cerebral Artery and its Main Cortical Branches Identified with Noninvasive Transcranial Color-Coded Duplex Sonography.

    Science.gov (United States)

    Frid, P E; Schreiber, S J; Pade, O; Doepp, F; Valdueza, J

    2015-11-01

    To differentiate PCA segments and cortical branches by means of transcranial color-coded duplex sonography (TCCD) and to measure flow parameters at rest and during visual stimulation. 60 healthy subjects with a good acoustic temporal bone window were examined. The main stem of the PCA (P1, P2 and P3) and 4 main cortical branches - the anterior temporal artery (ATA), the occipital temporal artery (OTA), the parietooccipital artery (POA) and the calcarine artery (CA) - were assessed using an axial transtemporal approach. Systolic and diastolic blood flow velocities (BFVs) were recorded at rest and during visual stimulation. Identification of the P1 segment of the PCA was successful in 97.5% (117/120) of cases. The P2 and P3 segments were visualized in all cases. The 4 main cortical branches could be identified to varying degrees: ATA in 88%, OTA in 96%, POA in 69% and CA in 62%. There was an evoked flow response in the P2 main stem and in all cortical branches. The most pronounced increase in diastolic/systolic BFV after visual stimulation test was seen in the CA (42%/35%), followed by P2 (30%/24%), the POA (27%/27%), the OTA (16%/13%) and the ATA (9%/8%). Insonation through the temporal bone window with TCCD confidently allows the assessment of the P1 to P3 segments of the PCA as well as the 2 proximal branches, the ATA and the OTA. An ultrasound-based classification of PCA anatomy and its cortical branches may be used as a noninvasive method for the evaluation of posterior circulation pathology.

  14. Comparison between manual and automated analysis for the quantification of carotid wall by using sonography. A validation study with CT

    International Nuclear Information System (INIS)

    Saba, Luca; Montisci, Roberto; Molinari, Filippo; Tallapally, Niranjan; Zeng, Guang; Mallarini, Giorgio; Suri, Jasjit S.

    2012-01-01

    Purpose: The purpose of this paper was to compare manual and automated analysis for the quantification of carotid wall obtained with sonography by using the computed tomography as validation technique. Material and methods: 21 consecutive patients underwent MDCTA and ultrasound analysis of carotid arteries (mean age 68 years; age range 59–81 years). The intima–media-thickness (IMT) of the 42 carotids was measured with novel and dedicated automated software analysis (called AtheroEdge™, Biomedical Technologies, Denver, CO, USA) and by four observers that manually calculated the IMT. The carotid artery wall thickness (CAWT) was also quantified in the CT datasets. Bland–Altman statistics was employed to measure the agreement between methods. A Student's t-test was used to test the differences between the IMT values of AtheroEdge™. The study obtained the IRB approval. Results: The correlation between automated AtheroEdge™ measurements and those of the human experts were equal to 95.5%, 73.5%, 88.9%, and 81.7%. The IMT coefficient of variation of the human experts was equal to 11.9%. By using a Student's t-test, the differences between the IMT values of AtheroEdge™ and those of the human experts were not found statistically significant (p value = 0.02). On comparing AtheroEdge™ (using Ultrasound) with CAWT (using CT), the results suggested a very good concordance of 84.96%. Conclusions: Data of this preliminary study indicate that automated software AtheroEdge™ can analyze with precision the IMT of carotid arteries and that the concordance with CT is optimal.

  15. Diagnostic accuracy of hysterosalpingo-foam-sonography to confirm tubal occlusion after Essure® placement as treatment for hydrosalpinges.

    Science.gov (United States)

    Dreyer, Kim; Hompes, Peter G A; Mijatovic, Velja

    2015-04-01

    Consensus globally is that hydrosalpinges need to be treated before IVF owing to their negative influence on outcomes. The current standard treatment is laparoscopic salpingectomy. A potential less invasive treatment is proximal occlusion of a hydrosalpinx by hysteroscopic placement of an Essure® device. Tubal occlusion after Essure® placement needs to be verified by hysterosalpingography (HSG). However, this is a painful examination, that exposes patients to radiation. Hysterosalpingo-foam sonography (HyFoSy) is a less invasive alternative test to confirm proximal tubal occlusion. This prospective diagnostic accuracy study evaluated if HyFoSy is as accurate as HSG to confirm proximal tubal occlusion after placement of an Essure® device as treatment for a hydrosalpinx before IVF. Thirty-eight treated hydrosalpinges in 26 women were evaluated. Proximal occlusion was verified by HyFoSy (index test) and HSG (standard reference). The accuracy of HyFoSy was 97.4% (95% CI 92.3% to 100.0%). Sensitivity and specificity were 97.1% (95% CI.84.6% to 99.5%) and 100.0% (95% CI 40.2% to 100.0%), respectively. After an Essure® device is placed as treatment for a hydrosalpinx before IVF, HyFoSy is as able as HSG to confirm proximal tubal occlusion. If HyFoSy demonstrates tubal patency, a subsequent HSG needs to be carried out to validate this finding. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  16. Basal ganglia perfusion using dynamic color Doppler sonography in infants with hypoxic ischemic encephalopathy receiving therapeutic hypothermia: a pilot study.

    Science.gov (United States)

    Faingold, Ricardo; Cassia, Guilherme; Morneault, Linda; Saint-Martin, Christine; Sant'Anna, Guilherme

    2016-10-01

    The objective of this study was to evaluate the cerebral perfusion of the basal ganglia in infants with hypoxic-ischemic encephalopathy (HIE) receiving hypothermia using dynamic color Doppler sonography (CDS) and investigate for any correlation between these measurements and survival. Head ultrasound (HUS) was performed with a 9S4 MHz sector transducer in HIE infants submitted to hypothermia as part of their routine care. Measurements of cerebral perfusion intensity (CPI) with an 11LW4 MHz linear array transducer were performed to obtain static images and DICOM color Doppler videos of the blood flow in the basal ganglia area. Clinical and radiological data were evaluated retrospectively. The video images were analyzed by two radiologists using dedicated software, which allows automatic quantification of color Doppler data from a region of interest (ROI) by dynamically assessing color pixels and flow velocity during the heart cycle. CPI is expressed in cm/sec and is calculated by multiplying the mean velocity of all pixels divided by the area of the ROI. Three videos of 3 seconds each were obtained of the ROI, in the coronal plane, and used to calculate the CPI. Data are presented as mean ± SEM or median (quartiles). A total of 28 infants were included in this study: 16 male, 12 female. HUS was performed within the first 48 hours of therapeutic hypothermia treatment. CPI values were significantly higher in the seven non-survivors when compared to survivors (0.226±0.221 vs . 0.111±0.082 cm/sec; P=0.02). Increased perfusion intensity of the basal ganglia area within the first 48 of therapeutic hypothermia treatment was associated with poor outcome in neonates with HIE.

  17. Predictive value of focused assessment with sonography for trauma (FAST) for laparotomy in unstable polytrauma Egyptians patients.

    Science.gov (United States)

    Elbaih, Adel Hamed; Abu-Elela, Sameh T

    2017-12-01

    The emergency physicians face significant clinical uncertainty when multiple trauma patients arrive in the emergency department (ED). The priorities for assessment and treatment of polytrauma patients are established in the primary survey. Focused assessment with sonography for trauma (FAST) is very essential clinical skill during trauma resuscitation. Use of point of care ultrasound among the trauma team working in the primary survey in emergency care settings is lacking in Suez Canal University Hospitals even ultrasound machine not available in ED. This study aims to evaluate the accuracy of FAST in hemodynamically unstable polytraumatized patients and to determine its role as an indication of laparotomy. This study is a cross-sectional study included 150 polytrauma patients with a blunt mechanism admitted in Suez Canal University Hospital. Firstly primary survey by airway check, cervical spine securing with neck collar, maintenance of breathing/circulation and management of life threading conditions if present were conducted accordingly to ATLS (advanced trauma life support) guidelines. The patients were assessed in the primary survey using the FAST as a tool to determine the presence of intra-abdominal collection. A total of 150 patients, and FAST scans were performed in all cases. The sensitivity and specificity were 92.6% and 100%, respectively. The negative predictive value was 92%, while the positive predictive value of FAST was 100%. The accuracy of FAST was 96%. FAST is an important method to detect intra-abdominal fluid in the initial assessment in hemodynamically unstable polytrauma patients with high accuracy. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  18. Occult pneumothorax in trauma patients: should this be sought in the focused assessment with sonography for trauma examination?

    Science.gov (United States)

    Tam, Michael M K

    2005-01-01

    At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.

  19. High-frequency ultrasound probe sonography staging for colorectal neoplasia with superficial morphology: its utility and impact on patient management.

    Science.gov (United States)

    Urban, Ondrej; Kliment, Martin; Fojtik, Petr; Falt, Premysl; Orhalmi, Julius; Vitek, Petr; Holeczy, Pavol

    2011-10-01

    This prospective study aimed to evaluate the impact of high-frequency ultrasound probe sonography (HFUPS) staging on the management of patients with superficial colorectal neoplasia (SCN) as determined by the endoscopic characteristics of lesions. Consecutive patients referred for endoscopic treatment of nonpedunculated SCN were enrolled in this study. A lesion was considered high risk if a depressed area or invasive pit pattern was present. The gold standard for final staging included histology from endoscopic or surgical resection. The impact on treatment was defined as any modification of the therapeutic algorithm based on the result of the HFUPS examination compared with that based on endoscopy alone. In this study, 48 lesions in 48 patients were evaluated. Of these, 28 (58%) were considered high risk, and the remaining 20 (42%) were regarded as low risk. A total of seven lesions (15%) that could not be examined with HFUPS and another non-neoplastic lesion were excluded from final analysis. For the remaining 40 lesions, the overall accuracy of the HFUPS examination to predict the correct T-stage was 90% (95% confidence interval [CI], 77-96%). The HFUPS examination had a positive impact on the treatment of 0 low-risk and 11 high-risk (42%) lesions. The impact of HFUPS on the treatment of SCN depends on their endoscopic characteristics. It is negligible for low-risk SCNs, and these lesions can be treated on the basis of their endoscopic appearance alone. Nevertheless, compared with endoscopy alone, HFUPS changed the subsequent therapeutic approach in a positive way for up to 42% of high-risk lesions, including those with a depressed component and an invasive pit pattern. These endoscopic features can therefore be recommended as the entry criteria for an HFUPS examination.

  20. Hepatic Vein Arrival Time for Diagnosis of Liver Cirrhosis: A 10-Year Single-Center Experience With Contrast-Enhanced Sonography.

    Science.gov (United States)

    Abbattista, Teresa; Ridolfi, Francesco; Consalvo, Giovanni Traina; Brunelli, Eugenio

    2016-10-01

    To evaluate the performance of contrast-enhanced sonography with a second-generation contrast agent in assessing the severity of chronic diffuse liver disease and differentiating cirrhotic from noncirrhotic liver disease. Contrast-enhanced sonography was performed after intravenous bolus injection of a second-generation contrast agent in 14 healthy control participants and 160 consecutive patients with cirrhotic and noncirrhotic liver disease (n = 78 and 82, respectively) enrolled between March 2004 and April 2014. The intensity of enhancement in a main hepatic vein was used to determine hepatic vein arrival time, time to peak intensity, and peak contrast enhancement. The hepatic vein arrival time was lower in cirrhotic patients compared with both noncirrhotic patients and controls (mean ± SD, 15.0 ± 2.8, 21.5 ± 3.4, and 25.6 ± 4.7 seconds, respectively; P < .05). The hepatic vein arrival time in noncirrhotic patients was also significantly lower than that in controls (P < .05). The time to peak intensity was significantly lower in cirrhotic patients compared with noncirrhotic patients and controls (40.7 ± 13.7, 49.4 ± 12.8, and 51.2 ± 13.7 seconds; P < .05). A receiver operating characteristic curve analysis revealed that the hepatic vein arrival time more accurately excluded a diagnosis of liver cirrhosis than the time to peak intensity (area under the receiver operating characteristic curve, 0.953 versus 0.694). Specifically, a hepatic vein arrival time cutoff value of 17 seconds excluded liver cirrhosis with 91.1% sensitivity and 93.6% specificity. Contrast-enhanced sonography is a valid alternative method for noninvasive staging of liver diseases. The hepatic vein arrival time could be used to exclude liver cirrhosis in a clinical setting.

  1. Diagnostic value of sonography, ultrasound-guided fine-needle aspiration cytology, and diffusion-weighted MRI in the characterization of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Schueller-Weidekamm, Claudia [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: claudia.schueller-weidekamm@meduniwien.ac.at; Schueller, Gerd [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kaserer, Klaus [Department of Pathology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Scheuba, Christian [Department of Surgery, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Ringl, Helmut; Weber, Michael; Czerny, Christian; Herneth, Andreas M. [Department of Diagnostic Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-03-15

    Introduction: The purpose of this prospective study was to assess the diagnostic value of different modalities for the characterization of cold thyroid nodules. Methods: In 35 patients with cold nodules, thyroid carcinoma was suspected on scintigraphy. These patients were prospectively investigated with sonography, ultrasound-guided fine-needle aspiration (USgFNA), and quantitative diffusion-weighted imaging magnetic resonance imaging (DWI) (navigated echo-planar imaging; maximum b-value 800 s/mm{sup 2}) prior to surgery. The sonographic findings, USgFNA cytology, and the apparent diffusion coefficient (ADC) values of DWI were correlated with the postoperative histology of benign and malignant lesions. Statistical analysis was performed with the Kruskal-Wallis test and the Fisher's exact test. P < .05 denoted statistical significance. Results: The accuracy of sonography and USgFNA was 64% and 68.8%, respectively. The sensitivity was 86.7% and 80%, respectively. Specificity was only 57.2% and 50%, respectively. The median ADC values for carcinoma and adenoma were 2.73 x 10{sup -3} mm{sup 2}/s and 1.93 x 10{sup -3} mm{sup 2}/s, respectively (P < .001). There was no significant difference between the median ADC value for Hashimoto thyroiditis (3.46 x 10{sup -3} mm{sup 2}/s) and carcinoma. An ADC value of 2.25 x 10{sup -3} mm{sup 2}/s or higher was proven to be the cut-off value for differentiating between benign and malignant cold thyroid nodules, with an accuracy of 88%, a sensitivity of 85%, and a specificity of 100%. Conclusions: These results show that quantitative DWI is a more reliable diagnostic method for differentiation between benign and malignant thyroid lesions than sonography or USgFNA. However, further studies including a larger study population are necessary to confirm our study results.

  2. Comparative retrospective studies on the findings of CT, sonography, urography, and angiography in retroperitoneal organ structures - random study on a mixed group of subjects

    International Nuclear Information System (INIS)

    Spahn, J.

    1982-01-01

    The objective of this dissertation was, in a retrospective study, to compare the diagnostic accuracy of the CT with that of sonography and, as far as possible, of other X-ray methods for kidneys, the pancreas, suprarenal glands and retroperitoneal lymph nodes. The data of all patients was looked at who were examined in the afore mentioned regions using a computerised tomograph, at the Deutsche Klinik fuer Diagnostik in Wiesbaden between May 1978 and January 1980. In all, 288 cases were studied. (orig./MG) [de

  3. [Can TOF MRA replace duplex and Doppler sonography in preoperative assessment of the carotid arteries? A prospective comparison and review of the literature].

    Science.gov (United States)

    Krappel, F A; Bauer, E; Harland, U

    2002-01-01

    To examine the quality and usefulness of time-of-flight MR-angiography and duplex-doppler sonography, respectively, in assessment of the extracranial arteries before cervical spine operations. Patients scheduled for operations of the cervical spine had an MRI plus TOF as well as a duplex and Doppler scan. At the time of the examination the radiologist and the neurologist in charge were blinded for the study. Endpoints were not only the accuracy of the procedures but more so which method improved the preoperative process most. Twenty patients were examined so far. Only in one case did the result differ when a complete occlusion diagnosed sonographically was judged as a severe stenosis on MRA. One patient did not tolerate the MRA for the extra 5 minutes necessary, therefore a contrast-enhanced MRA was performed. MRA eased the preoperative process as imaging of the pathology and the carotids were realised in one step. The costs were slightly higher for MRA than for duplex-doppler sonography. TOF-MRA can replace the duplex-doppler examination in the preoperative assessment of the carotids and has the potential to streamline the preoperative time schedule. Similar to duplex and doppler, in order to be accurate enough the method requires a high degree of expertise from the radiologist.

  4. Measurement of tumour size with mammography, sonography and magnetic resonance imaging as compared to histological tumour size in primary breast cancer

    International Nuclear Information System (INIS)

    Gruber, Ines V; Rueckert, Miriam; Kagan, Karl O; Staebler, Annette; Siegmann, Katja C; Hartkopf, Andreas; Wallwiener, Diethelm; Hahn, Markus

    2013-01-01

    Tumour size in breast cancer influences therapeutic decisions. The purpose of this study was to evaluate sizing of primary breast cancer using mammography, sonography and magnetic resonance imaging (MRI) and thereby establish which imaging method most accurately corresponds with the size of the histological result. Data from 121 patients with primary breast cancer were analysed in a retrospective study. The results were divided into the groups “ductal carcinoma in situ (DCIS)”, invasive ductal carcinoma (IDC) + ductal carcinoma in situ (DCIS)”, “invasive ductal carcinoma (IDC)”, “invasive lobular carcinoma (ILC)” and “other tumours” (tubular, medullary, mucinous and papillary breast cancer). The largest tumour diameter was chosen as the sizing reference in each case. Bland-Altman analysis was used to determine to what extent the imaging tumour size correlated with the histopathological tumour sizes. Tumour size was found to be significantly underestimated with sonography, especially for the tumour groups IDC + DCIS, IDC and ILC. The greatest difference between sonographic sizing and actual histological tumour size was found with invasive lobular breast cancer. There was no significant difference between mammographic and histological sizing. MRI overestimated non-significantly the tumour size and is superior to the other imaging techniques in sizing of IDC + DCIS and ILC. The histological subtype should be included in imaging interpretation for planning surgery in order to estimate the histological tumour size as accurately as possible

  5. The Natural History of Kidney Graft Cortical Microcirculation Determined by Real-Time Contrast-Enhanced Sonography (RT-CES).

    Science.gov (United States)

    Jiménez, Carlos; López, María Ovidia; Ros, Amaia; Aguilar, Ana; Menendez, David; Rivas, Begoña; Santana, María José; Vaca, Marco Antonio; Escuin, Fernando; Madero, Rosario; Selgas, Rafael

    2016-01-01

    Kidney transplantation is the therapy of choice for end-stage kidney disease. Graft's life span is shorter than expected due in part to the delayed diagnosis of various complications, specifically those related to silent progression. It is recognized that serum creatinine levels and proteinuria are poor markers of mild kidney lesions, which results in delayed clinical information. There are many investigation looking for early markers of graft damage. Decreasing kidney graft cortical microcirculation has been related to poor prognosis in kidney transplantation. Cortical capillary blood flow (CCBF) can be measured by real-time contrast-enhanced sonography (RT-CES). Our aim was to describe the natural history of CCBF over time under diverse conditions of kidney transplantation, to explore the influence of donor conditions and recipient events, and to determine the capacity of CCBF for predicting renal function in medium term. RT-CES was performed in 79 consecutive kidney transplant recipients during the first year under regular clinical practice. Cortical capillary blood flow was measured. Clinical variables were analyzed. The influence of CCBF has been determined by univariate and multivariate analysis using mixed regression models based on sequential measurements for each patient over time. We used a first-order autoregression model as the structure of the covariation between measures. The post-hoc comparisons were considered using the Bonferroni correction. The CCBF values varied significantly over the study periods and were significantly lower at 48 h and day 7. Brain-death donor age and CCBF levels showed an inverse relationship (r: -0.62, p<0.001). Living donors showed higher mean CCBF levels than brain-death donors at each point in the study. These significant differences persisted at month 12 (54.5 ± 28.2 vs 33.7 ± 30 dB/sec, living vs brain-death donor, respectively, p = 0.004) despite similar serum creatinine levels (1.5 ± 0.3 and 1.5 ± 0.5 mg/dL). A

  6. Sonography of scrotal trauma

    International Nuclear Information System (INIS)

    Rao, Meka Srinivasa; Arjun, Kalyanpur

    2012-01-01

    The purpose of this article is to depict the spectrum of scrotal injuries in blunt trauma. Scrotal injuries are not very common and are mostly due to blunt trauma from direct injury, sports injuries or motor vehicle accidents. To minimize complications and ensure testicular salvage, rapid and accurate diagnosis is necessary. High-resolution USG is the investigation of choice, as it is readily available, accurate and has been seen to improve outcomes. An understanding of and familiarity with the sonographic appearance of scrotal injuries on the part of the radiologist/sonographer is therefore of key importance

  7. Sonography of scrotal trauma

    Directory of Open Access Journals (Sweden)

    Meka Srinivasa Rao

    2012-01-01

    Full Text Available The purpose of this article is to depict the spectrum of scrotal injuries in blunt trauma. Scrotal injuries are not very common and are mostly due to blunt trauma from direct injury, sports injuries or motor vehicle accidents. To minimize complications and ensure testicular salvage, rapid and accurate diagnosis is necessary. High-resolution USG is the investigation of choice, as it is readily available, accurate and has been seen to improve outcomes. An understanding of and familiarity with the sonographic appearance of scrotal injuries on the part of the radiologist/sonographer is therefore of key importance.

  8. Early fetal anatomical sonography.

    LENUS (Irish Health Repository)

    Donnelly, Jennifer C

    2012-10-01

    Over the past decade, prenatal screening and diagnosis has moved from the second into the first trimester, with aneuploidy screening becoming both feasible and effective. With vast improvements in ultrasound technology, sonologists can now image the fetus in greater detail at all gestational ages. In the hands of experienced sonographers, anatomic surveys between 11 and 14 weeks can be carried out with good visualisation rates of many structures. It is important to be familiar with the normal development of the embryo and fetus, and to be aware of the major anatomical landmarks whose absence or presence may be deemed normal or abnormal depending on the gestational age. Some structural abnormalities will nearly always be detected, some will never be and some are potentially detectable depending on a number of factors.

  9. Diagnostic value of high-resolution B-mode and power-mode sonography in the follow-up of thyroid cancer.

    Science.gov (United States)

    Görges, Rainer; Eising, E G; Fotescu, D; Renzing-Köhler, K; Frilling, A; Schmid, K W; Bockisch, A; Dirsch, O

    2003-02-01

    Ultrasonography is an established diagnostic modality in the follow-up of thyroid cancer. Color flow Doppler has been proposed by some authors as an additional tool for differentiating benign from malignant cervical lesions in various types of head and neck cancer. Over the last few years, a new generation of high-resolution ultrasound platforms with the "power-mode" feature has become available, that also enables the imaging of small vessel blood flow. The objective of our study was to find ways of optimizing the differentiation of benign and malignant cervical tumors in thyroid cancer follow-up by means of sonography. Hundred and twelve cervical lesions in 90 patients with thyroid cancer were evaluated by high-end ultrasonography (Sonoline Elegra, Siemens) using a small-part transducer (7.5 L 40, Siemens). B-mode sonography was performed at a frequency of 8 MHz. The Solbiati index (SI= ratio of largest to smallest diameter), configuration, echogenicity, intranodular structures, and margins were assessed. Perinodular and intranodular blood flow was evaluated by color flow Doppler (PRF 1250 Hz for conventional color flow Doppler, 868 Hz for power-mode Doppler). Possible malignancy was validated by histology, cytology, scintigraphy, and follow-up. Thirty five lesions were benign (diameter 0.4-3.0 cm) and 77 were malignant (0.4-5.4 cm). The patients were randomized into a test group and a learning group to determine the diagnostic value of various ultrasound criteria by means of statistical analysis. In the learning group, decision rules based on the dichotomized criteria were developed using a logistic regression model. Sensitivity and specificity of these decision rules were then evaluated in the test group. The presence of an echocomplex pattern or irregular hyperechoic small intranodular structures (criterion A) and the presence of an irregular diffuse intranodular blood flow (criterion B) are the best indicators of malignancy, whereas an SI >2 is highly

  10. Significance of the determination of doppler sonography haemodynamic indices for the assessment of distal perfusion in patients with critical ischemia of lower limbs

    Directory of Open Access Journals (Sweden)

    Čizmić Milica

    2006-01-01

    Full Text Available Background/Aim: The perfusion of tissue, especially the muscles of the lower limbs (LL, implies the blood flow that carries enough nutrition, energy materials and oxygen. The aim of this study was to determine whether the decreased Doppler sonography parameters, resistance index (RI, and pulsatility index (PI were significant as indicators of irreversible ischemia of LL. Methods. In 40 patients (mean age 66±14.9 years, 21% women and 79% men with the signs of critical ischemia of LL, Lariche-Fontaine class III and IV, we performed contrast angiography of the LL arteries, and perfusion scintigraphy of LL using, thallium-201, while we performed Doppler sonography to determine resistance index (RI, as well as pulsatility index (PI. After that, all the patients were treated with vasodilatation using Bergmann's solution within a 10-day period. Following that, all the patients underwent the determination of haemodynamic indices RI and PI applying the methods of Doppler sonography. The obtained values of RI and PI indices revealed no clinical recovery which suggested the irreversibility of critical ischemia (unsuccessful therapy in 100% of the patients, and clinical recovery which suggested the reversibility of the disease (unsuccessful therapy in 80% of the patients. Results. The obtained values of PI = 0-0.3 and RI = 0-0.25 for the examined LL arteries were the indicators of irreversible ischemia. A significant correlation between the values of RI in the distal parts of a. tibialis anterior and posterior was proved, as well as between the decreased perfusion of LL determined by tallium-201 (p < 0.05, r = 0.43, and a tibialis anterior (p = 0.05, r = 0.38. There was, however, no statistically significant correlation between the angiographic values and perfusion scintigraphy of LL. Conclusion. The obtained values of haemodynamic RI and PI indices should be a novel approach for introducing a new criteria for the assessment of reversible and irreversible

  11. Hepatic hemangiomas with peritumoral sparing of fatty infiltration in hepatic steatosis: findings on contrast-enhanced MR imaging and on sonography

    International Nuclear Information System (INIS)

    Kim, Min Jeong; Kim, Kyoung Won; Won, Hyung Jin

    2006-01-01

    We wanted to determine the frequency of peritumoral sparing of fatty infiltration (PTSF) around hepatic hemangioma in hepatic steatosis and to evaluate the finding of these tumors on dynamic contrast-enhanced MR imaging and on sonography. This study included 76 hemangiomas in 67 patients suffering with hepatic steatosis. A diagnosis of hemangioma was based on the histologic findings, hemangioma SPECT or a compatible enhancement pattern on the dynamic contrast-enhanced MR study. For chemical shifting, PTSF was defined when there wasn't any decrease in signal intensity of the liver parenchyma on the opposed-phase images as compared with the in-phase images, and this intensity appeared as a hyperintense area around the tumor. We evaluated the frequency of PTSF and we analyzed if the presence of PTSF was related to the tumor size, the rapidity of enhancement or an associated arterioportal shunt. Among those, sonographic images were available in 55 hemangiomas. We also evaluated the sonographic appearances of hemangiomas with PTSF. Of the 76 hemangiomas, PTSF was noted on the MR chemical-shift images in 57 hemangiomas (75%). There was no significant relationship between tumor size and the presence of PTSF (ρ = .578). However, this finding was more frequently found in high-flow hemangiomas than in the slow-flow ones (ρ = .0038) and it was also related to the presence of associated arterioportal shunt (ρ = .0158). Sonographically, hemangiomas with PTSF were commonly surrounded by a peritumoral low-echoic area (28/41, 68%); these tumors more frequently showed a thin high-echoic rim on sonography than did the tumors without this finding (ρ = .0055). PTSF is commonly seen in hemangiomas in hepatic steatosis patients. Hepatic hemangiomas with PTSF tend to show rapid enhancement on dynamic MR imaging and this is accompanied by arterioportal shunt. They tend to be seen as an iso-or low-echoic mass with a thin high-echoic rim on sonography, and the mass is commonly

  12. Hepatic hemangiomas with peritumoral sparing of fatty infiltration in hepatic steatosis: findings on contrast-enhanced MR imaging and on sonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jeong; Kim, Kyoung Won; Won, Hyung Jin [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2006-12-15

    We wanted to determine the frequency of peritumoral sparing of fatty infiltration (PTSF) around hepatic hemangioma in hepatic steatosis and to evaluate the finding of these tumors on dynamic contrast-enhanced MR imaging and on sonography. This study included 76 hemangiomas in 67 patients suffering with hepatic steatosis. A diagnosis of hemangioma was based on the histologic findings, hemangioma SPECT or a compatible enhancement pattern on the dynamic contrast-enhanced MR study. For chemical shifting, PTSF was defined when there wasn't any decrease in signal intensity of the liver parenchyma on the opposed-phase images as compared with the in-phase images, and this intensity appeared as a hyperintense area around the tumor. We evaluated the frequency of PTSF and we analyzed if the presence of PTSF was related to the tumor size, the rapidity of enhancement or an associated arterioportal shunt. Among those, sonographic images were available in 55 hemangiomas. We also evaluated the sonographic appearances of hemangiomas with PTSF. Of the 76 hemangiomas, PTSF was noted on the MR chemical-shift images in 57 hemangiomas (75%). There was no significant relationship between tumor size and the presence of PTSF ({rho} = .578). However, this finding was more frequently found in high-flow hemangiomas than in the slow-flow ones ({rho} = .0038) and it was also related to the presence of associated arterioportal shunt ({rho} = .0158). Sonographically, hemangiomas with PTSF were commonly surrounded by a peritumoral low-echoic area (28/41, 68%); these tumors more frequently showed a thin high-echoic rim on sonography than did the tumors without this finding ({rho} = .0055). PTSF is commonly seen in hemangiomas in hepatic steatosis patients. Hepatic hemangiomas with PTSF tend to show rapid enhancement on dynamic MR imaging and this is accompanied by arterioportal shunt. They tend to be seen as an iso-or low-echoic mass with a thin high-echoic rim on sonography, and the mass is

  13. Role of [18F]fluorodeoxyglucose positron emission tomography-computed tomography, sonography, and sonographically guided fine-needle aspiration biopsy in the diagnosis of axillary lymph nodes in patients with breast cancer: comparison of diagnostic performance.

    Science.gov (United States)

    Sohn, Yu-Mee; Hong, Il Ki; Han, Kyunghwa

    2014-06-01

    The aim of this study was to compare the diagnostic performance of [(18)F]fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) with that of sonography and sonographically guided fine-needle aspiration (FNA) for determining the preoperative axillary lymph node (ALN) status and to evaluate the factors related to false-negative PET-CT, sonographic, and FNA results in ALN staging of invasive ductal carcinoma. From March 2009 to July 2012, 226 patients had a diagnosis of primary breast cancer. Among these patients, 107 constituted the study population after exclusion of transferred patients and patients with breast cancer other than invasive ductal carcinoma. The diagnostic performance of the modalities was compared with pathologic reports. Univariate and multivariate analyses were used to evaluate the relationship between clinicopathologic factors (symptoms, T stage, hormone receptors, and histologic grade), false-negative results, and true-negative results on PET-CT, sonography, and FNA. Of the 107 patients, 45 (42.1%) had positive results on final pathologic analysis of ALNs. Sonographically guided FNA had a significantly higher specificity, positive predictive value, accuracy, and area under the receiver operating characteristic curve than sonography and PET-CT (P < .01). When sonography and PET-CT were combined, the sensitivity was significantly improved (P = .019) compared with sonography alone. When FNA and PET-CT were combined, the sensitivity and negative predictive value were significantly increased compared with each modality (P < .01). Sonographically guided FNA was found to be an excellent diagnostic tool for preoperative evaluation of the ALN status. To obviate the step of sentinel lymph node biopsy for determining the ALN status, combined evaluation of ALNs by these modalities may be more complementary than the use of a single modality. © 2014 by the American Institute of Ultrasound in Medicine.

  14. Predictive value of vertebral artery extracranial color-coded duplex sonography for ischemic stroke-related vertigo.

    Science.gov (United States)

    Liou, Li-Min; Lin, Hsiu-Fen; Huang, I-Fang; Chang, Yang-Pei; Lin, Ruey-Tay; Lai, Chiou-Lian

    2013-12-01

    Vertigo can be a major presentation of posterior circulation stroke and can be easily misdiagnosed because of its complicated presentation. We thus prospectively assessed the predictive value of vertebral artery extracranial color-coded duplex sonography (ECCS) for the prediction of ischemic stroke-related vertigo. The inclusion criteria were: (1) a sensation of whirling (vertigo); (2) intractable vertigo for more than 1 hour despite appropriate treatment; and (3) those who could complete cranial magnetic resonance imaging (MRI) and vertebral artery (V2 segment) ECCS studies. Eventually, 76 consecutive participants with vertigo were enrolled from Kaohsiung Municipal Hsiao-Kang Hospital, Kaohsiung, Taiwan between August 2010 and August 2011. Demographic data, neurological symptoms, neurologic examinations, and V2 ECCS were assessed. We chose the parameters of peak systolic velocity (PSV), end diastolic velocity (EDV), PSV/EDV, mean velocity (MV), resistance index (RI), and pulsatility index (PI) to represent the hemodynamics. Values from both sides of V2 segments were averaged. We then calculated the average RI (aRI), average PI (aPI), average PSV (aPSV)/EDV, and average (aMV). Axial and coronal diffusion-weighted MRI findings determined the existence of acute ischemic stroke. We grouped and analyzed participants in two ways (way I and way II analyses) based on the diffusion-weighted MRI findings (to determine whether there was acute stroke) and neurological examinations. Using way I analysis, the "MRI (+)" group had significantly higher impedance (aRI, aPI, and aPSV/EDV ratio) and lower velocity (aPSV, aEDV, and aMV(PSV + EDV/2)), compared to the "MRI (-)" group. The cutoff value/sensitivity/specificity of aPSV, aEDV, aMV, aPI, aRI, and aPSV/EDV between the MRI (+) and MRI (-) groups were 41.15/61.5/66.0 (p = 0.0101), 14.55/69.2/72.0 (p = 0.0003), 29.10/92.1/38.0 (p = 0.0013), 1.07/76.9/64.0 (p = 0.0066), 0.62/76.9/64.0 (p = 0.0076), and 2.69/80.8/66.0 (p = 0

  15. Right hemispheric language dominance in a right-handed male with a right frontal tumor shown by functional transcranial Doppler sonography.

    Science.gov (United States)

    Haag, A; Preibisch, C; Sure, U; Knake, S; Heinze, S; Krakow, K; Rosenow, F; Hamer, H M

    2006-02-01

    A 38-year-old, right-handed man with late-onset right frontal epilepsy due to a ganglioglioma and atypical right hemispheric language dominance is described. Language dominance was investigated with functional transcranial Doppler sonography (fTCD), and language localization with functional magnetic resonance imaging (fMRI). During a word generation task, fTCD showed atypical right hemispheric language dominance, which was confirmed by fMRI using a semantic word comparison and a word stem completion task. This information helped to guide the resective procedure, which left the patient seizure-free and did not induce new deficits. Functional TCD appears to be a useful and reliable screening tool for determining hemispheric language dominance, even in patients with atypical language representation. Functional MRI may be used to confirm fTCD results and further localize eloquent cortex.

  16. Detection of cerebrovascular disease in patients with sickle cell disease using transcranial Doppler sonography: correlation with MRI, MRA and conventional angiography

    Energy Technology Data Exchange (ETDEWEB)

    Verlhac, S. [Service de Radiologie, Centre Hospitalier Intercommunal, 94 - Creteil (France); Bernaudin, F. [Service de Pediatrie, Centre Hospitalier Intercommunal, 94 - Creteil (France); Tortrat, D. [Association Claude Bernard, 75 - Paris (France); Brugieres, P. [Service de Neuroradiologie, Hopital Henri Mondor, 94 - Creteil (France); Mage, K. [Service de Radiologie, Centre Hospitalier Intercommunal, 94 - Creteil (France); Gaston, A. [Service de Neuroradiologie, Hopital Henri Mondor, 94 - Creteil (France); Reinert, P. [Service de Pediatrie, Centre Hospitalier Intercommunal, 94 - Creteil (France)

    1995-11-01

    A prospective study of 58 patients with sickle cell disease (SCD) by transcranial Doppler sonography (TCD) included both MRI and MRA in patients over 7 years of age and those with abnormal TCD. Arteriography was performed in cases where a stenosis was suspected on TCD. Middle cerebral artery (MCA) and basilar artery (BA) velocities were significantly higher in the sickle cell hemoglobin SS group than in the hemoglobin SC group. Patients with a MCA mean velocity of over 1.90 m/s had stenoses found by arteriography. Patients with unilaterally undetectable MCA flow had experienced a stroke and MCA thrombosis was confirmed at MRA and arteriography. We concluded that TCD is valuable in detecting arterial stenosis in SCD and will lead to consideration of these patients for intensive therapy, such as bone marrow transplantation (BMT) or transfusion regimes. (orig.)

  17. Detection of cerebrovascular disease in patients with sickle cell disease using transcranial Doppler sonography: correlation with MRI, MRA and conventional angiography

    International Nuclear Information System (INIS)

    Verlhac, S.; Bernaudin, F.; Tortrat, D.; Brugieres, P.; Mage, K.; Gaston, A.; Reinert, P.

    1995-01-01

    A prospective study of 58 patients with sickle cell disease (SCD) by transcranial Doppler sonography (TCD) included both MRI and MRA in patients over 7 years of age and those with abnormal TCD. Arteriography was performed in cases where a stenosis was suspected on TCD. Middle cerebral artery (MCA) and basilar artery (BA) velocities were significantly higher in the sickle cell hemoglobin SS group than in the hemoglobin SC group. Patients with a MCA mean velocity of over 1.90 m/s had stenoses found by arteriography. Patients with unilaterally undetectable MCA flow had experienced a stroke and MCA thrombosis was confirmed at MRA and arteriography. We concluded that TCD is valuable in detecting arterial stenosis in SCD and will lead to consideration of these patients for intensive therapy, such as bone marrow transplantation (BMT) or transfusion regimes. (orig.)

  18. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography

    International Nuclear Information System (INIS)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J.; Stahel, P.F.; Ertel, W.

    2004-01-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  19. The use of real time ultrasound scanning as a teaching method of anatomy in an undergraduate sonography and medical imaging degree in an Australian university

    International Nuclear Information System (INIS)

    Bowman, A.; Lawson, C.; McKillup, S.

    2016-01-01

    Background: Real-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections. Aim: To assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods medical imaging and sonography students consider effective for understanding human anatomy. Method: Surveys were distributed to two consecutive cohorts of first year medical imaging and medical sonography students at CQUniversity. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA. Results: Real-time ultrasound scanning was the most preferred method of delivery for anatomy classes overall especially compared to computer programs, videos, 3-D radiological images and dissection. Specifically, students indicated that ultrasound scanning was the preferred method to encourage learning from experience (F 7,231  = 2.942, p = 0.006), to develop team skills (F 7,231  = 4.550, p < 0.006), to follow complex instructions (F 7,231  = 4.656 p < 0.001) and to appreciate anatomical variation (F 7,231  = 2.067, p = 0.048). Dissection was the least favoured teaching method. Conclusion: Real-time ultrasound scanning is a useful tool for teaching anatomy, and animal dissections are a poor substitute for the use of human cadavers. - Highlights: • Real-time ultrasound scanning is a valid teaching tool for human anatomy. • Real-time ultrasound is preferred by students compared to other teaching methods. • Dissection is the least favoured method to learn anatomy. • Ultrasound encourages learning from experience and develops team skills.

  20. The value of computerized tomography and sonography in different types of pancreatitis, judged on the basis of a diagnosis previously confirmed by retrograde endoscopic cholangiopancreaticography and the pancreomycin-secretin test

    International Nuclear Information System (INIS)

    Sewing, G.

    1985-01-01

    The blind study described here pointed to a diagnostic superiority of computered tomography, the results of which in chronic pancreatitis were judged to be better than those of sonography, chiefly because of its high sensitivity in the detection of calcified deposits in the pancreas. The values determined, in particular those relating to the specifity of the methods used, were lower than the data given by other authors. From the findings revealed here there was, however, sufficient evidence to confirm that both computered tomography and sonography certainly have their merits as non-invasive methods of morphological examination in the diagnosis of pancreatitis. They should therefore be used, preferably in combined form, prior to any other diagnostic measures that may be more hazardous to the patient. (MBC) [de

  1. Transabdominal pulse inversion harmonic imaging improves assesment of ovarian morphology in virgin patients with PCOS: comparison with conventional B-mode sonography

    Energy Technology Data Exchange (ETDEWEB)

    Mahmutyazicioglu, Kamran; Tanriverdi, H. Alper; Oezdemir, Hueseyin; Barut, Aykut; Davsanci, Halit; Guendogdu, Sadi

    2005-02-01

    Objective: In virgin policystic ovary syndrome (PCOS) patients transabdominal sonography is the preferential method of the pelvic examination. The purpose of this study was to determine ovarian morphology by the transabdominal route by pulse inversion harmonic imaging (PIHI) in virgin PCOS patients and to compare the diagnostic image quality with conventional B-mode ultrasonography (CBU). Methods: Fifty-two ovaries in 26 virgin patients were evaluated by the transabdominal approach. Each ovary was examined using both PIHI and CBU. The sharpness of the follicular cysts walls, degree of internal echo definitions of the follicle cysts and overall ovarian conspicuity was assessed subjectively, using 4 point scoring (0, being worst; 3, being best score). The number of countable follicles, the size of largest and smallest ovarian follicle and ovarian volumes were assessed quantitively by both techniques. The effect of body mass index (BMI) on qualitative and quantitative scoring was evaluated. Results: The sharpness of the cyst wall and internal echo structure was significantly better with PIHI than with CBU (P < 0.001 P < 0.001 and P < 0.001, respectively). PIHI improved overall ovarian conspicuity in 41 (78.8%) of 52 examination. The number of countable follicles was significantly lower with CBU (P < 0.001). The maximum diameter of the largest follicle was larger with PIHI sonography to compared CBU (P < 0.001). Mean ovarian volume was significantly larger with CBU (P < 0.001). When data were analyzed separately according to BMI, number of non-diagnostic overall ovarian conspicuity scores with CBU was markedly high in obese patients (88% with CBU versus 3.8% with PIHI). On the other hand, mean number of countable follicles with CBU became much more lower in the obese group (P < 0.001). Conclusion: In virgin PCOS patients, when compared to transabdominal CBU, PIHI significantly improved the detection of ovarian follicles, especially in high BMI obese subjects, through

  2. Transabdominal pulse inversion harmonic imaging improves assesment of ovarian morphology in virgin patients with PCOS: comparison with conventional B-mode sonography

    International Nuclear Information System (INIS)

    Mahmutyazicioglu, Kamran; Tanriverdi, H. Alper; Oezdemir, Hueseyin; Barut, Aykut; Davsanci, Halit; Guendogdu, Sadi

    2005-01-01

    Objective: In virgin policystic ovary syndrome (PCOS) patients transabdominal sonography is the preferential method of the pelvic examination. The purpose of this study was to determine ovarian morphology by the transabdominal route by pulse inversion harmonic imaging (PIHI) in virgin PCOS patients and to compare the diagnostic image quality with conventional B-mode ultrasonography (CBU). Methods: Fifty-two ovaries in 26 virgin patients were evaluated by the transabdominal approach. Each ovary was examined using both PIHI and CBU. The sharpness of the follicular cysts walls, degree of internal echo definitions of the follicle cysts and overall ovarian conspicuity was assessed subjectively, using 4 point scoring (0, being worst; 3, being best score). The number of countable follicles, the size of largest and smallest ovarian follicle and ovarian volumes were assessed quantitively by both techniques. The effect of body mass index (BMI) on qualitative and quantitative scoring was evaluated. Results: The sharpness of the cyst wall and internal echo structure was significantly better with PIHI than with CBU (P < 0.001 P < 0.001 and P < 0.001, respectively). PIHI improved overall ovarian conspicuity in 41 (78.8%) of 52 examination. The number of countable follicles was significantly lower with CBU (P < 0.001). The maximum diameter of the largest follicle was larger with PIHI sonography to compared CBU (P < 0.001). Mean ovarian volume was significantly larger with CBU (P < 0.001). When data were analyzed separately according to BMI, number of non-diagnostic overall ovarian conspicuity scores with CBU was markedly high in obese patients (88% with CBU versus 3.8% with PIHI). On the other hand, mean number of countable follicles with CBU became much more lower in the obese group (P < 0.001). Conclusion: In virgin PCOS patients, when compared to transabdominal CBU, PIHI significantly improved the detection of ovarian follicles, especially in high BMI obese subjects, through

  3. Assessing the usefulness of B-mode and colour Doppler sonography, and measurements of circulating progesterone concentrations for determining ovarian responses in superovulated ewes.

    Science.gov (United States)

    Oliveira, Mef; Ribeiro, I F; Rodriguez, Mgk; Maciel, G S; Fonseca, J F; Brandão, F Z; Bartlewski, P M

    2018-06-01

    The main goal of this study was to assess the usefulness of two imaging modalities, namely the B-mode and colour Doppler sonography, and serum progesterone (P 4 ) concentrations for determining the ovarian response in superovulated ewes. Twenty-four sexually mature Santa Inês ewes underwent the superovulatory treatment consisting of eight injections of porcine FSH (total dose of 200 or 133 or 100 mg; n = 8 ewes/total dose) given at 12-hr intervals and initiated 48 hr before CIDR ® (Pfizer Inc., Auckland, New Zealand) removal. Six days after natural mating, the ovaries of all donor ewes were visualized and examined with transrectal ultrasonography and then with videolaparoscopy to identify and enumerate corpora lutea (CL) and luteinized unovulated follicles (LUFs). Jugular blood samples were collected just prior to ovarian examinations. The total number of CL (r = .78 and 0.83, p ewes. © 2018 Blackwell Verlag GmbH.

  4. Bone scintigraphy compared to MRI and ultrasound in the early diagnosis of arthritis; Skelettszintigraphie im Vergleich mit MRT und Sonographie beim Fruehnachweis der Arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Sandrock, D. [Klinikum Chemnitz gGmbH, Klinik fuer Nuklearmedizin, Chemnitz (Germany)

    2006-12-15

    Chronic inflammatory arthritis is recognized specifically by bone erosions, caused by characteristic pannus tissue. In the finger joints dynamic low-Tesla MRI is nearly double but not completely sensitive in the detection of erosions than conventional radiography, sonography takes an intermediate position. Less specific signs of synovitis and tenosynovitis are shown with high sensitivity by both 3(2)-phase bone scintigraphy and ultrasound, MRI is less sensitive in this respect. However, standard situation of inflammation in bone scintigraphy - positive finding in early as well as late phase - is of surprisingly low sensitivity, any singular finding in the early or late phase has to be regarded as positive. Specificity of these singular findings is nevertheless sufficiently high, acute inflammatory joint changes and even erosions are also seen with MRI in obviously healthy persons. Only 2-phase bone scintigraphy is easily able to present a simultaneous survey of all joints of the body. For this reason 2-phase bone scintigraphy is most suitable for exclusion but also for primary diagnosis of disease, specification must be done afterwards by other imaging modalities or by laboratory findings. (orig.)

  5. Acetazolamide stimulation test in patients with unilateral internal carotid artery stenosis using Tc-99m HMPAO SPECT and transcranial doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Na, J. H. [Inha University Hospital, Incheon (Korea, Republic of)

    2007-07-01

    We compared perfusion reserve by acetazolamide (ACZ) challenged brain perfusion SPECT and cerebral vasoreactivity (CVR) by transcranial Doppler sonography (TCD) in patients with unilateral internal carotid artery stenosis. This study was conducted prospectively in 37 consecutive patients with angiographically proven unilateral internal carotid artery stenosis (stenosis> 50%). We estimated % CVR (100? {l_brace}post-ACZ mean velocity (cm/sec) - Pre-ACZ mean velocity (cm/sec){r_brace} / pre-ACZ mean velocity) by TCD. The % CVR was compared with perfusion reserve of SPECT. The % CVR of MCA and ICA was significantly decreased in the ipsilateral side to the carotid stenosis (p<0.05). The CVR impairment was more severe when cerebral infarct is already developed (p<0.01). There was a significant correlation between the degree of carotid stenosis and the CVR (p<0.01). In the area of impaired perfusion reserve on the SPECT, the estimated CVR by TCD was significantly lower (p<0.05), even to the negative value, implying that there is actually steal phenomenon in that area. ACZ challenge can actually decrease cerebral blood flow in the area of impaired perfusion reserve on brain SPECT. So we should be very cautiously performing in ACZ challenge especially when there is a severe carotid stenosis because there is a possibility of developing hemodynamic stroke.

  6. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model.

    Science.gov (United States)

    Kozinszky, Zoltan; Surányi, Andrea; Péics, Hajnalka; Molnár, András; Pál, Attila

    2015-08-01

    The aim of this study was to determine the utility of a new mathematical model in volumetric assessment of the placenta using 2-D ultrasound. Placental volumetry was performed in a prospective cross-sectional survey by virtual organ computer-aided analysis (VOCAL) with the help of a shell-off method in 346 uncomplicated pregnancies according to STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Furthermore, placental thickness, length and height were measured with the 2-D technique to estimate placental volume based on the mathematical formula for the volume of "the shell of the spherical sector." Fetal size was also assessed by 2-D sonography. The placental volumes measured by 2-D and 3-D techniques had a correlation of 0.86. In the first trimester, the correlation was 0.82, and later during pregnancy, it was 0.86. Placental volumetry using "the circle-shaped shell of the spherical sector" mathematical model with 2-D ultrasound technique may be introduced into everyday practice to screen for placental volume deviations associated with adverse pregnancy outcome. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. The relevance of free fluid between intestinal loops detected by sonography in the clinical assessment of small bowel obstruction in adults

    International Nuclear Information System (INIS)

    Grassi, Roberto; Romano, Stefania; D'Amario, Fenesia; Giorgio Rossi, Antonio; Romano, Luigia; Pinto, Fabio; Di Mizio, Roberto

    2004-01-01

    Introduction: The main role of the radiologist in the management of patients with suspicion of small bowel obstruction is to help triage patients into those that need immediate surgical intervention from those that require medical therapy or delayed surgery. Ultrasound examination is usually considered not helpful in bowel obstruction because of air in the intestinal lumen that interferes the evaluation of the intestinal loops, however recently some Authors attested the increasing important role of sonography in the acute abdominal disease. Aim of our report is to demonstrate the value of free fluid detected by US in differentiating between low and high-grade small bowel obstruction. Materials and methods: The study is based on 742 consecutive patients who presented symptoms of the acute abdomen; all patients had undergone initial serial abdominal plain film and US examinations prior to any medical intervention. We reviewed the imaging findings of 150 cases in whom small bowel obstruction was clinically suspected and confirmed at surgery. We consider the following radiographic and US findings: dilatation of small bowel loops; bowel wall thickness; presence of air-fluid levels; thickness of valvulae conniventes; evidence of peristalsis; presence and echogenicity of extraluminal fluid. We looked at the value of extraluminal peritoneal fluid at US examination in differentiating low and high-grade small bowel obstruction based on the surgical outcome. Results: In 46 patients altered peristaltic activity, thin bowel walls, fluid filled loops with hyperechoic spots in the bowel segment proximal to obstruction were noted at US, whereas radiographic features were: moderate dilatation of small bowel loops, with thin bowel wall and evidence of numerous and subtle valvulae conniventes; presence of air-fluid levels was also noted. In 70 other patients, US examination revealed all the findings described in the precedent cases and also the presence of free extraluminal fluid

  8. The relevance of free fluid between intestinal loops detected by sonography in the clinical assessment of small bowel obstruction in adults

    Energy Technology Data Exchange (ETDEWEB)

    Grassi, Roberto; Romano, Stefania E-mail: stefromano@libero.it; D' Amario, Fenesia; Giorgio Rossi, Antonio; Romano, Luigia; Pinto, Fabio; Di Mizio, Roberto

    2004-04-01

    Introduction: The main role of the radiologist in the management of patients with suspicion of small bowel obstruction is to help triage patients into those that need immediate surgical intervention from those that require medical therapy or delayed surgery. Ultrasound examination is usually considered not helpful in bowel obstruction because of air in the intestinal lumen that interferes the evaluation of the intestinal loops, however recently some Authors attested the increasing important role of sonography in the acute abdominal disease. Aim of our report is to demonstrate the value of free fluid detected by US in differentiating between low and high-grade small bowel obstruction. Materials and methods: The study is based on 742 consecutive patients who presented symptoms of the acute abdomen; all patients had undergone initial serial abdominal plain film and US examinations prior to any medical intervention. We reviewed the imaging findings of 150 cases in whom small bowel obstruction was clinically suspected and confirmed at surgery. We consider the following radiographic and US findings: dilatation of small bowel loops; bowel wall thickness; presence of air-fluid levels; thickness of valvulae conniventes; evidence of peristalsis; presence and echogenicity of extraluminal fluid. We looked at the value of extraluminal peritoneal fluid at US examination in differentiating low and high-grade small bowel obstruction based on the surgical outcome. Results: In 46 patients altered peristaltic activity, thin bowel walls, fluid filled loops with hyperechoic spots in the bowel segment proximal to obstruction were noted at US, whereas radiographic features were: moderate dilatation of small bowel loops, with thin bowel wall and evidence of numerous and subtle valvulae conniventes; presence of air-fluid levels was also noted. In 70 other patients, US examination revealed all the findings described in the precedent cases and also the presence of free extraluminal fluid

  9. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    Science.gov (United States)

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Fade-out sign on hepatic tissue harmonic compound sonography: A value as a new sign in the diagnosis of fatty liver

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Kim, Kyeong Ah; Lee, Jongmee; Park, Yang Shin; Choi, Jae Woong; Seo, Tae Seok; Park, Cheol Min

    2011-01-01

    Objective: To evaluate the value of the fade-out sign in the diagnosis of fatty liver (FL) on hepatic ultrasound (US). Methods: We evaluated 127 patients who underwent hepatic US, including 70 patients with FL and 57 normal control subjects. US images were qualitatively evaluated for the presence of the fade-out sign. This sign was considered present if there was a dark band on the deep portion of the liver on the harmonic image when compound sonography (CS) was converted to tissue harmonic CS mode. The degrees of FL were classified into mild, moderate, and severe. The distribution of lengths of dark bands in three groups was examined, and a multiple comparison of the average dark band length was carried out using one-way ANOVA. Results: The fade-out sign was seen in 55 of 70 FL patients (78.6%) compared to 3 of 57 control subjects (5.3%) (p < 0.001). The sensitivity, specificity, accuracy, and positive predictive value of the fade-out sign for the US diagnosis of FL were 78%, 94%, 85.8%, and 94.8%, respectively. Among the 70 FL, there were 28 mild FL (mean length of dark band; 8.3 mm ± 8.2), 31 moderate FL (mean; 28 mm ± 6.3), and 11 severe FL (mean; 51 mm ± 8.3). There were significant differences in band length according to severity (p < 0.01). Conclusion: The fade-out sign on hepatic harmonic US was frequently present in FL. As fat infiltration increased, the fade-out sign lengthened. The fade-out sign offers a specific and new sign of FL.

  11. Role of focused assessment with sonography for trauma as a screening tool for blunt abdominal trauma in young children after high energy trauma.

    Science.gov (United States)

    Tummers, W; van Schuppen, J; Langeveld, H; Wilde, J; Banderker, E; van As, A

    2016-06-01

    The objective of the study was to review the utility of focused assessement with sonography for trauma (FAST) as a screening tool for blunt abdominal trauma (BAT) in children involved in high energy trauma (HET), and to determine whether a FAST could replace computed tomography (CT) in clinical decision-making regarding paediatric BAT. Children presented at the Trauma Unit of the Red Cross War Memorial Children's Hospital, Cape Town, after HET, and underwent both a physical examination and a FAST. The presence of free fluid in the abdomen and pelvis was assessed using a FAST. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) for identifying intraabdominal injury were calculated for the physical examination and the FAST, both individually and when combined. Seventy-five patients were included as per the criteria for HET as follows: pedestrian motor vehicle crashes (MVCs) ( n = 46), assault ( n = 14), fall from a height ( n = 9), MVC passenger ( n = 4) and other ( n = 2). The ages of the patients ranged from 3 months to 13 years. The sensitivity of the physical examination was 0.80, specificity 0.83, PPV 0.42 and NPV 0.96. The sensitivity of the FAST was 0.50, specificity 1.00, PPV 1.00 and NPV 0.93. Sensitivity increased to 0.90 when the physical examination was combined with the FAST. Nonoperative management was used in 73 patients. Two underwent an operation. A FAST should be performed in combination with a physical examination on every paediatric patient involved in HET to detect BAT. When both are negative, nonoperative management can be implemented without fear of missing a clinically significant injury. FAST is a safe, effective and easily accessible alternative to CT, which avoids ionising radiation and aids in clinical decision-making.

  12. Diagnostic Accuracy of Focused Assessment with Sonography for Blunt Abdominal Trauma in Pediatric Patients Performed by Emergency Medicine Residents versus Radiology Residents

    Directory of Open Access Journals (Sweden)

    Farhad Heydari

    2018-05-01

    Full Text Available Introduction: Focused assessment with sonography for trauma (FAST has been shown to be useful to detect intraperitoneal free fluid in patients with blunt abdominal trauma (BAT. Objective: We compared the diagnostic accuracy of FAST performed by emergency medicine residents (EMRs and radiology residents (RRs in pediatric patients with BAT. Method: In this prospective study, pediatric patients with BAT and high energy trauma who were referred to the emergency department (ED at Al-Zahra and Kashani hospitals in Isfahan, Iran, were evaluated using FAST, first by EMRs and subsequently by RRs. The reports provided by the two resident groups were compared with the final outcome based on the results of the abdominal computed tomography (CT, operative exploration, and clinical observation. Results: A total of 101 patients with a median age of 6.75 ± 3.2 years were enrolled in the study between January 2013 and May 2014. These patients were evaluated using FAST, first by EMRs and subsequently by RRs. A good diagnostic agreement was noted between the results of the FAST scans performed by EMRs and RRs (κ = 0.865, P < 0.001. The sensitivity, specificity, positive and negative predictive values, and accuracy in evaluating the intraperitoneal free fluid were 72.2%, 85.5%, 52%, 93.3%, and 83.2%, respectively, when FAST was performed by EMRs and 72.2%, 86.7%, 54.2%, 93.5%, and 84.2%, respectively, when FAST was performed by RRs. No significant differences were seen between the EMR- and RR-performed FAST. Conclusion: In this study, FAST performed by EMRs had acceptable diagnostic value, similar to that performed by RRs, in patients with BAT.

  13. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    Science.gov (United States)

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax: experience at a community based level I trauma center.

    Science.gov (United States)

    Nandipati, Kalyana C; Allamaneni, Shyam; Kakarla, Ravindra; Wong, Alfredo; Richards, Neil; Satterfield, James; Turner, James W; Sung, Kae-Jae

    2011-05-01

    Early identification of pneumothorax is crucial to reduce the mortality in critically injured patients. The objective of our study is to investigate the utility of surgeon performed extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax. We prospectively analysed 204 trauma patients in our level I trauma center over a period of 12 (06/2007-05/2008) months in whom EFAST was performed. The patients' demographics, type of injury, clinical examination findings (decreased air entry), CXR, EFAST and CT scan findings were entered into the data base. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. Of 204 patients (mean age--43.01+/-19.5 years, sex--male 152, female 52) 21 (10.3%) patients had pneumothorax. Of 21 patients who had pneumothorax 12 were due to blunt trauma and 9 were due to penetrating trauma. The diagnosis of pneumothorax in 204 patients demonstrated the following: clinical examination was positive in 17 patients (true positive in 13/21, 62%; 4 were false positive and 8 were false negative), CXR was positive in 16 (true positive in 15/19, 79%; 1 false positive, 4 missed and 2 CXR not performed before chest tube) patients and EFAST was positive in 21 patients (20 were true positive [95.2%], 1 false positive and 1 false negative). In diagnosing pneumothorax EFAST has significantly higher sensitivity compared to the CXR (P=0.02). Surgeon performed trauma room extended FAST is simple and has higher sensitivity compared to the chest X-ray and clinical examination in detecting pneumothorax. Published by Elsevier Ltd.

  15. [Regarding Authorized Qualifications in Sonography].

    Science.gov (United States)

    Kaneko, Kazuhiko

    2015-04-01

    Today, I will talk about the profession "Ultrasound Technologist." The written examination to gain this license includes clinical questions (35 questions including those using photographs; 70 minutes to answer) and basic questions related to ultrasound for medical use (35 questions including those requiring calculation; 70 minutes to answer). The answer to each question is selected from 5 alternatives. The questions used in the examination are not officially disclosed. The minimum score needed to pass the examination is 60 points for both the test with clinical questions and that with basic questions. My practice to prepare for the basic questions related to ultrasound for medical use involved attempting to answer a collection of questions while understanding physical phenomena by watching animations on the related Internet homepage. I wrote down how to approach the questions (including those requiring calculation), together with comments and answers to each of them. Basic questions about ultrasound for medical use differ little from year to year because there are few questions reflecting highlights or specific topics prevailing in a given year. So, to prepare for basic questions, I think it is important to become familiar with the trends of questions and how to answer them through repeating mock tests many times. Preparing for clinical questions is very difficult. Although many collections of clinical questions are available at bookstores, I have the impression that most of the questions in these collections have already been used in past examinations, and there is now a tendency for more precise clinical questions targeting specific areas to be adopted for the examination. The questions adopted in the past are becoming outdated, while the techniques of ultrasonography are continuing to advance. So, clinical questions are being increasingly adopted that cover recent topics in this field. In any event, knowledge covering extensive areas is needed to prepare for the clinical questions. For those who desire to attain the license "ultrasound technologist" despite insufficient clinical experience, the only possible approach may be to read through collections of questions and reference books.

  16. Hip sonography in the newborn

    International Nuclear Information System (INIS)

    Riboni, G.; Serantoni, S.; De Simoni, M.; Bascape', P.; Facchini, R.; Pirovano, G.

    1991-01-01

    The authors report the data relative to 1507 cases studied with clinical and US examinations, in the neonatal period, in order to exclude hip dysplasia dislocation. US examination was carried out according to Graf's technique and the newborns were classified according to US hip type, to clinical examination and to possible risk factors. The patients were included in a protocol including orthopedic and US controls. Seventeen treated infants were considered as pathologic. Ten of them had IIc or D hips ar birth; the other 7, with IIa hips at birth, presented a X-ray pathologic hip after the 4th months of life. At about one year of age all infants could normally walk, excpet for one who was being treated with herness. No statistically significant differences were observed between the number of pathologic infants in the risk group (1.7%) and that in the no-risk group (0.8%). Clinical examination of the newborn has low sensitivity in detecting pathologic hips. On the basis of their results, thw authors belive US examination of the newborn to be a valuable screening method to diagnose hip dysplasia/dislocation. Moreover, Graf's morphologic method is the best one for US screening of the hip in the neonatal period

  17. A radiologist's guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    International Nuclear Information System (INIS)

    Gerscovich, E.O.

    1997-01-01

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab

  18. A radiologist`s guide to the imaging in the diagnosis and treatment of developmental dysplasia of the hip. Pt. 1. General considerations, physical examination as applied to real-time sonography and radiography

    Energy Technology Data Exchange (ETDEWEB)

    Gerscovich, E.O. [Department of Radiology, University of California, Davis Medical Center, 2516 Stockton Blvd., Ticon II Building, Sacramento, CA 95817 (United States)

    1997-07-07

    Developmental dysplasia of the hip (DDH) has a broad spectrum of presentation with the minor findings resolving spontaneously and the most severe ones resulting in disability, if not diagnosed early in life. Diagnosis in the first few months of life allows conservative treatment with complete resolution in most cases. Suspicion of DDH is based on ethnic, family, and pregnancy history, and on physical examination of the newborn. Imaging assists in the diagnosis and follows the treatment. Different modalities have their own advantages and disadvantages. This article deals with the description of the disease, risk factors, statistics, the physical examination as applied to real-time sonography, and imaging (plain radiography, arthrography, computed tomography, and magnetic resonance imaging). (orig.). With 26 figs., 1 tab.

  19. Three dimensional strained semiconductors

    Science.gov (United States)

    Voss, Lars; Conway, Adam; Nikolic, Rebecca J.; Leao, Cedric Rocha; Shao, Qinghui

    2016-11-08

    In one embodiment, an apparatus includes a three dimensional structure comprising a semiconductor material, and at least one thin film in contact with at least one exterior surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the three dimensional structure. In another embodiment, a method includes forming a three dimensional structure comprising a semiconductor material, and depositing at least one thin film on at least one surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the structure.

  20. Three-dimensional colour Doppler of ductus venosus agenesis in ...

    African Journals Online (AJOL)

    was bilateral pleural effusion with generalised subcutaneous oedema suggestive of hydrops fetalis (Fig. 1B). Colour Doppler sonography revealed the umbilical vein draining into the portal sinus with non-visualisation of the DV, which would connect the portal sinus with the inferior vena cava (IVC) (Figs 1C and 1D). Hence ...

  1. Two- and three-dimensional prenatal sonographic diagnosis of prune-belly syndrome.

    Science.gov (United States)

    Chen, Lizhu; Cai, Ailu; Wang, Xiaoguang; Wang, Bing; Li, Jingyu

    2010-06-01

    We report the prenatal diagnosis of 6 cases of Prune-belly syndrome in the 2(nd) trimester. The sonographic diagnosis was based on the findings of oligohydramnios, renal anomalies, and a lower abdominal cystic mass representing the abnormal dilatation of the bladder on conventional 2-dimensional sonographic examination. We discuss the role of Doppler imaging and 3-dimensional sonography as complementary methods to conventional sonography. Four of our 6 cases were confirmed with associated defects.

  2. 正常中晚期妊娠输尿管射尿的彩色多普勒检查%Observations of ureteral jets in normal second- and third-trimester pregnancy with color Doppler sonography

    Institute of Scientific and Technical Information of China (English)

    王家刚

    2001-01-01

    目的:了解正常中晚期妊娠输尿管的尿动力学改变是否影响输尿管射尿。方法:彩色多普勒超声观察32例中晚期妊娠妇女和11例非妊娠对照者膀胱射尿情况,观察时间5分钟。结果:妊娠受试者平均射尿5.9次/分,左、右侧射尿频率平均差异百分比为49%。对照组平均射尿7.3次/分,左、右射尿频率差异百分比为13%。受试组与对照组之间射尿对称性方面具有显著性差异(P<0.05)。32例妊娠受试者中有7例有单侧射尿缺乏,而对照者中无1例单侧射尿缺乏。结论:在妊娠中晚期,由于两侧输尿管射尿的不对称性,用彩色多普勒超声检测输尿管射尿诊断中晚期妊娠合并输尿管结石应慎用。%Objective: To understand whether ureteral urodynamic changes accompanying normal second- and third-trimester pregnancy altered the pattern of ureteral jets. Methods: Ureteral jets were observed with color Doppler sonography for five minutes in 32women during the second or third trimester of pregnancy and in 11 non-pregnant controls. Result: A mean of 5.9 jets/ minute were detected in the pregnant subjects. The mean percentage difference in frequency of jets between the right and left sides was 49%. A mean of 7.3 jets/ minute were detected and the mean percentage difference was 13% for controls. The two groups were significantly different in jet symmetry (P<0.05). Unilateral absence of jets was observed in seven pregnant subjects and in no controls. Conclusion: Because of asymmetry in ureteral jet between the left and right sides during the later stages of pregnacy, caution is recommended in the use of color Doppler sonography to diagnose ureteral urolithiasis during the later stages of pregnancy.

  3. Three dimensional canonical transformations

    International Nuclear Information System (INIS)

    Tegmen, A.

    2010-01-01

    A generic construction of canonical transformations is given in three-dimensional phase spaces on which Nambu bracket is imposed. First, the canonical transformations are defined as based on cannonade transformations. Second, it is shown that determination of the generating functions and the transformation itself for given generating function is possible by solving correspondent Pfaffian differential equations. Generating functions of type are introduced and all of them are listed. Infinitesimal canonical transformations are also discussed as the complementary subject. Finally, it is shown that decomposition of canonical transformations is also possible in three-dimensional phase spaces as in the usual two-dimensional ones.

  4. Three-dimensional neuroimaging

    International Nuclear Information System (INIS)

    Toga, A.W.

    1990-01-01

    This book reports on new neuroimaging technologies that are revolutionizing the study of the brain be enabling investigators to visualize its structure and entire pattern of functional activity in three dimensions. The book provides a theoretical and practical explanation of the new science of creating three-dimensional computer images of the brain. The coverage includes a review of the technology and methodology of neuroimaging, the instrumentation and procedures, issues of quantification, analytic protocols, and descriptions of neuroimaging systems. Examples are given to illustrate the use of three-dimensional enuroimaging to quantitate spatial measurements, perform analysis of autoradiographic and histological studies, and study the relationship between brain structure and function

  5. Three-Dimensional Flows

    CERN Document Server

    Araujo, Vitor; Viana, Marcelo

    2010-01-01

    In this book, the authors present the elements of a general theory for flows on three-dimensional compact boundaryless manifolds, encompassing flows with equilibria accumulated by regular orbits. The book aims to provide a global perspective of this theory and make it easier for the reader to digest the growing literature on this subject. This is not the first book on the subject of dynamical systems, but there are distinct aspects which together make this book unique. Firstly, this book treats mostly continuous time dynamical systems, instead of its discrete counterpart, exhaustively treated

  6. Three dimensional system integration

    CERN Document Server

    Papanikolaou, Antonis; Radojcic, Riko

    2010-01-01

    Three-dimensional (3D) integrated circuit (IC) stacking is the next big step in electronic system integration. It enables packing more functionality, as well as integration of heterogeneous materials, devices, and signals, in the same space (volume). This results in consumer electronics (e.g., mobile, handheld devices) which can run more powerful applications, such as full-length movies and 3D games, with longer battery life. This technology is so promising that it is expected to be a mainstream technology a few years from now, less than 10-15 years from its original conception. To achieve thi

  7. Study of the association degree between cerebral magnetic resonance signal and the transcranial sonography Estudio del grado de asociación entre la señal de resonancia magnética cerebral y la ecografía transcraneal Estudi del grau d'associació entre el senya de ressonancia magnètica cerebral i l'ecografia transcranial

    OpenAIRE

    Carrascosa Morales, Rafael

    2012-01-01

    El coregistre d'una imatge d'ecografia transcraneal amb un volum de ressonància magnètica cerebral i estudi del grau d'associació entre elles. Projecte el·laborat amb Transmural Biotech SL English: The study tries to achieve a multimodal registration between a transcranial sonography (TCS) and a cerebral magnetic resonance volume. After the registration stage, a statistical analysis of each brain matter (white matter, gray matter and cerebrospinal fluid) was performed to demonstrate the...

  8. Three Dimensional Dirac Semimetals

    Science.gov (United States)

    Zaheer, Saad

    2014-03-01

    Dirac points on the Fermi surface of two dimensional graphene are responsible for its unique electronic behavior. One can ask whether any three dimensional materials support similar pseudorelativistic physics in their bulk electronic spectra. This possibility has been investigated theoretically and is now supported by two successful experimental demonstrations reported during the last year. In this talk, I will summarize the various ways in which Dirac semimetals can be realized in three dimensions with primary focus on a specific theory developed on the basis of representations of crystal spacegroups. A three dimensional Dirac (Weyl) semimetal can appear in the presence (absence) of inversion symmetry by tuning parameters to the phase boundary separating a bulk insulating and a topological insulating phase. More generally, we find that specific rules governing crystal symmetry representations of electrons with spin lead to robust Dirac points at high symmetry points in the Brillouin zone. Combining these rules with microscopic considerations identifies six candidate Dirac semimetals. Another method towards engineering Dirac semimetals involves combining crystal symmetry and band inversion. Several candidate materials have been proposed utilizing this mechanism and one of the candidates has been successfully demonstrated as a Dirac semimetal in two independent experiments. Work carried out in collaboration with: Julia A. Steinberg, Steve M. Young, J.C.Y. Teo, C.L. Kane, E.J. Mele and Andrew M. Rappe.

  9. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  10. Three dimensional energy profile:

    International Nuclear Information System (INIS)

    Kowsari, Reza; Zerriffi, Hisham

    2011-01-01

    The provision of adequate, reliable, and affordable energy has been considered as a cornerstone of development. More than one-third of the world's population has a very limited access to modern energy services and suffers from its various negative consequences. Researchers have been exploring various dimensions of household energy use in order to design strategies to provide secure access to modern energy services. However, despite more than three decades of effort, our understanding of household energy use patterns is very limited, particularly in the context of rural regions of the developing world. Through this paper, the past and the current trends in the field of energy analysis are investigated. The literature on rural energy and energy transition in developing world has been explored and the factors affecting households' decisions on energy use are listed. The and the factors affecting households' decisions on energy use are listed. The gaps identified in the literature on rural household energy analysis provide a basis for developing an alternative model that can create a more realistic view of household energy use. The three dimensional energy profile is presented as a new conceptual model for assessment of household energy use. This framework acts as a basis for building new theoretical and empirical models of rural household energy use. - Highlights: ► Reviews literature on household energy, energy transitions and decision-making in developing countries. ► Identifies gaps in rural household energy analysis and develops a new conceptual framework. ► The 3-d energy profile provides a holistic view of household energy system characteristics. ► Illustrates the use of the framework for understanding household energy transitions.

  11. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  12. Three-dimensional ICT reconstruction

    International Nuclear Information System (INIS)

    Zhang Aidong; Li Ju; Chen Fa; Sun Lingxia

    2005-01-01

    The three-dimensional ICT reconstruction method is the hot topic of recent ICT technology research. In the context, qualified visual three-dimensional ICT pictures are achieved through multi-piece two-dimensional images accumulation by, combining with thresholding method and linear interpolation. Different direction and different position images of the reconstructed pictures are got by rotation and interception respectively. The convenient and quick method is significantly instructive to more complicated three-dimensional reconstruction of ICT images. (authors)

  13. Three-dimensional ICT reconstruction

    International Nuclear Information System (INIS)

    Zhang Aidong; Li Ju; Chen Fa; Sun Lingxia

    2004-01-01

    The three-dimensional ICT reconstruction method is the hot topic of recent ICT technology research. In the context qualified visual three-dimensional ICT pictures are achieved through multi-piece two-dimensional images accumulation by order, combining with thresholding method and linear interpolation. Different direction and different position images of the reconstructed pictures are got by rotation and interception respectively. The convenient and quick method is significantly instructive to more complicated three-dimensional reconstruction of ICT images. (authors)

  14. Sonography of pathological changes in the hand

    Directory of Open Access Journals (Sweden)

    Anna Dębek

    2014-03-01

    Full Text Available Everyday medical practice shows that most common problems within the hand result from overload, injuries and degeneration. Dorsal side pathologies such as de Quervain’s and Wartenberg’s disease, intersection syndrome or degenerative lesions of carpometacarpal joint of the thumb discussed in the paper can be accurately diagnosed and differentiated by means of ultrasound examination. Ultrasound is similarly powerful in detection and grading of traumatic lesions involving extensor tendons and their sagittal bands or the flexor tendons and their pulleys. In the case of carpal tunnel syndrome one can not only visualize the median nerve but also other structures of the tunnel that may cause compression. Similarly ulnar nerve compression within the Guyon’s canal can be well evaluated. In cases of nerve trauma one can precisely define the level, and in cases of nerve discontinuity, the distance between stumps can be measured which is important in surgery planning. Often nerve trauma is a sequelae of tendon reconstruction. In such cases scars and nerve entrapment can be depicted. Tumors within a hand are usually benign, of which the most common are ganglia. On ultrasound examination a connection between a ganglion and its source (usually a joint or sheath can frequently be defined. The relationship of tumors to nerves, tendon sheaths or vessels may suggest their nature. Ultrasound with dynamic tissue assessment is a very valuable adjunct to clinical examination.

  15. Sonography of the cervix at term gestation

    NARCIS (Netherlands)

    Meijer-Hoogeveen, M.

    2007-01-01

    Abstract During pregnancy the firm cartilage-like consistency of the cervix is transformed to soft tissue. This transformation is called "cervical ripening" and enables the cervix to dilate and facilitate parturition. In 1960, the Bishop Score was introduced to assess cervical ripeness before

  16. Sonography of iatrogenic pneumothorax in pediatric patients

    Science.gov (United States)

    2013-01-01

    Pneumothorax is defined as the presence of air in the pleural cavity. The incidence of iatrogenic pneumothorax in the pediatric population is 0.3–0.48 in 1000 patients. A conventional chest X-ray, in some cases supplemented with chest computed tomography, is a typical imaging examination used to confirm the diagnosis of pneumothorax. Within the last years, the relevance of transthoracic lung ultrasound in the diagnostic process of this disease entity has greatly increased. This is confirmed by the opinion of a group of experts in ultrasound lung imaging in patients in a life-threatening condition, who strongly recommend a transthoracic ultrasound examination for the diagnosis of pneumothorax in such patients. These data constituted the basis for initiating the prospective studies on the application of this method in pneumothorax diagnosis in patients of pediatric hematology and oncology wards. Aim The aim of the study was to present the possibility of using the transthoracic lung ultrasound in the diagnostic process of pneumothorax in pediatric patients, with particular attention paid to its iatrogenic form. The article discusses sonographic criteria for pneumothorax diagnosis in pediatric patients, including the sensitivity and specificity of the method, in relation to conventional chest X-ray. Material and methods The prospective studies included a group of patients treated in the Clinic of Pediatrics, Pediatric Hematology, Oncology and Endocrinology of the Academic Clinical Centre (Medical University of Gdańsk, Poland) in whom a central venous catheter was placed in the subclavian veins. The studies lasted for one year – from 1 July 2011 to 30 June 2012. The examined group comprised 63 patients – 25 girls (39.7%) and 38 boys (60.3%) aged from 1 to 17. The analysis included the results of 115 ultrasound examinations conducted in this group. Results In t he examined group with suspected or diagnosed neoplasm, iatrogenic pneumothorax was identified in 4 out of 63 patients (6.3%). In all cases, it was a consequence of procedures connected with the introduction of a central catheter. In the examined material, the sensitivity, specificity and predictive values (positive and negative) of the transthoracic lung ultrasound equaled 100%. Conclusions The transthoracic ultrasound examination is a highly effective method in diagnosing iatrogenic pneumothorax in pediatric patients. However, to confirm this conclusion, multicenter studies, among considerably larger populations, are necessary. PMID:26675373

  17. High resolution sonography of sublingual space

    International Nuclear Information System (INIS)

    Jain, P.

    2008-01-01

    Full text: Ultrasound examination of the sublingual region is a non-invasive, safe, inexpensive and widely available procedure, unaffected by the amalgam in teeth which is a source of considerable artefact on CT and MRI images. With a little practice and good understanding of the anatomy, ultrasound can be a very helpful primary examination. If the lesion is clearly seen, no further imaging may be required.

  18. Ulnar nerve sonography in leprosy neuropathy.

    Science.gov (United States)

    Wang, Zhu; Liu, Da-Yue; Lei, Yang-Yang; Yang, Zheng; Wang, Wei

    2016-01-01

    A 23-year-old woman presented with a half-year history of right forearm sensory and motor dysfunction. Ultrasound imaging revealed definite thickening of the right ulnar nerve trunk and inner epineurium, along with heterogeneous hypoechogenicity and unclear nerve fiber bundle. Color Doppler exhibited a rich blood supply, which was clearly different from the normal ulnar nerve presentation with a scarce blood supply. The patient subsequently underwent needle aspiration of the right ulnar nerve, and histopathological examination confirmed that granulomatous nodules had formed with a large number of infiltrating lymphocytes and a plurality of epithelioid cells in the fibrous connective tissues, with visible atypical foam cells and proliferous vascularization, consistent with leprosy. Our report will familiarize readers with the characteristic sonographic features of the ulnar nerve in leprosy, particularly because of the decreasing incidence of leprosy in recent years.

  19. Three dimensional MEMS supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei

    2011-10-15

    The overall objective of this research is to achieve compact supercapacitors with high capacitance, large power density, and long cycle life for using as micro power sources to drive low power devices and sensors. The main shortcoming of supercapacitors as a power source is that its energy density typically is about 1/10 of that of batteries. To achieve compact supercapacitors of large energy density, supercapacitors must be developed with high capacitance and power density which are mainly depended on the effective surface area of the electrodes of the supercapacitors. Many studies have been done to increase the effective surface area by modifying the electrode materials, however, much less investigations are focus on machining the electrodes. In my thesis work, micro- and nano-technologies are applied as technology approaches for machining the electrodes with three dimensional (3D) microstructures. More specific, Micro-electro-mechanical system (MEMS) fabrication process flow, which integrates the key process such as LIGA-like (German acronym for Lithographie, Galvanoformung, Abformung, which mean Lithography, Electroplating and Molding) technology or DRIE (deep reactive ion etching), has been developed to enable innovative designs of 3D MEMS supercapacitors which own the electrodes of significantly increased geometric area. Two types of 3D MEMS supercapcitors, based on LIGA-like and DRIE technology respectively, were designed and successfully created. The LIGA-like based 3D MEMS supercapacitor is with an interdigital 3D structure, and consists of silicon substrate, two electroplated nickel current collectors, two PPy (poly pyrrole) electrodes, and solid state electrolyte. The fabrication process flow developed includes the flowing key processes, SU-8 lithography, nickel electroplating, PPy polymerization and solid state electrolyte coating. Electrochemical tests showed that the single electrode of the supercapacitor has the specific capacitance of 0.058 F cm-2

  20. pO polarography, contrast enhanced color duplex sonography (CDS), [18F] fluoromisonidazole and [18F] fluorodeoxyglucose positron emission tomography: validated methods for the evaluation of therapy-relevant tumor oxygenation or only bricks in the puzzle of tumor hypoxia?

    International Nuclear Information System (INIS)

    Gagel, Bernd; Hamacher, Kurt; Coenen, Heinz H; Scholbach, Thomas; Maneschi, Payam; DiMartino, Ercole; Eble, Michael J; Piroth, Marc; Pinkawa, Michael; Reinartz, Patrick; Zimny, Michael; Kaiser, Hans J; Stanzel, Sven; Asadpour, Branka; Demirel, Cengiz

    2007-01-01

    The present study was conducted to analyze the value of ([ 18 F] fluoromisonidazole (FMISO) and [ 18 F]-2-fluoro-2'-deoxyglucose (FDG) PET as well as color pixel density (CPD) and tumor perfusion (TP) assessed by color duplex sonography (CDS) for determination of therapeutic relevant hypoxia. As a standard for measuring tissue oxygenation in human tumors, the invasive, computerized polarographic needle electrode system (pO 2 histography) was used for comparing the different non invasive measurements. Until now a total of 38 Patients with malignancies of the head and neck were examined. Tumor tissue pO 2 was measured using a pO 2 -histograph. The needle electrode was placed CT-controlled in the tumor without general or local anesthesia. To assess the biological and clinical relevance of oxygenation measurement, the relative frequency of pO 2 readings, with values ≤ 2.5, ≤ 5.0 and ≤ 10.0 mmHg, as well as mean and median pO 2 were stated. FMISO PET consisted of one static scan of the relevant region, performed 120 min after intravenous administration. FMISO tumor to muscle ratios (FMISO T/M ) and tumor to blood ratios (FMISO T/B ) were calculated. FDG PET of the lymph node metastases was performed 71 ± 17 min after intravenous administration. To visualize as many vessels as possible by CDS, a contrast enhancer (Levovist ® , Schering Corp., Germany) was administered. Color pixel density (CPD) was defined as the ratio of colored to grey pixels in a region of interest. From CDS signals two parameters were extracted: color hue – defining velocity (v) and color area – defining perfused area (A). Signal intensity as a measure of tissue perfusion (TP) was quantified as follows: TP = v mean × A mean . In order to investigate the degree of linear association, we calculated the Pearson correlation coefficient. Slight (|r| > 0.4) to moderate (|r| > 0.6) correlation was found between the parameters of pO 2 polarography (pO 2 readings with values ≤ 2.5, ≤ 5

  1. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  2. Three-dimensional biomedical imaging

    International Nuclear Information System (INIS)

    Robb, R.A.

    1985-01-01

    Scientists in biomedical imaging provide researchers, physicians, and academicians with an understanding of the fundamental theories and practical applications of three-dimensional biomedical imaging methodologies. Succinct descriptions of each imaging modality are supported by numerous diagrams and illustrations which clarify important concepts and demonstrate system performance in a variety of applications. Comparison of the different functional attributes, relative advantages and limitations, complementary capabilities, and future directions of three-dimensional biomedical imaging modalities are given. Volume 1: Introductions to Three-Dimensional Biomedical Imaging Photoelectronic-Digital Imaging for Diagnostic Radiology. X-Ray Computed Tomography - Basic Principles. X-Ray Computed Tomography - Implementation and Applications. X-Ray Computed Tomography: Advanced Systems and Applications in Biomedical Research and Diagnosis. Volume II: Single Photon Emission Computed Tomography. Position Emission Tomography (PET). Computerized Ultrasound Tomography. Fundamentals of NMR Imaging. Display of Multi-Dimensional Biomedical Image Information. Summary and Prognostications

  3. (Weakly) three-dimensional caseology

    International Nuclear Information System (INIS)

    Pomraning, G.C.

    1996-01-01

    The singular eigenfunction technique of Case for solving one-dimensional planar symmetry linear transport problems is extended to a restricted class of three-dimensional problems. This class involves planar geometry, but with forcing terms (either boundary conditions or internal sources) which are weakly dependent upon the transverse spatial variables. Our analysis involves a singular perturbation about the classic planar analysis, and leads to the usual Case discrete and continuum modes, but modulated by weakly dependent three-dimensional spatial functions. These functions satisfy parabolic differential equations, with a different diffusion coefficient for each mode. Representative one-speed time-independent transport problems are solved in terms of these generalised Case eigenfunctions. Our treatment is very heuristic, but may provide an impetus for more rigorous analysis. (author)

  4. Equilibrium: three-dimensional configurations

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    This chapter considers toroidal MHD configurations that are inherently three-dimensional. The motivation for investigation such complicated equilibria is that they possess the potential for providing toroidal confinement without the need of a net toroidal current. This leads to a number of advantages with respect to fusion power generation. First, the attractive feature of steady-state operation becomes more feasible since such configurations no longer require a toroidal current transformer. Second, with zero net current, one potentially dangerous class of MHD instabilities, the current-driven kink modes, is eliminated. Finally, three-dimensional configurations possess nondegenerate flux surfaces even in the absence of plasma pressure and plasma current. Although there is an enormous range of possible three-dimensional equilibria, the configurations of interest are accurately described as axisymmetric tori with superimposed helical fields; furthermore, they possess no net toroidal current. Instead, two different and less obvious restoring forces are developed: the helical sideband force and the toroidal dipole current force. Each is discussed in detail in Chapter 7. A detailed discussion of the parallel current constraint, including its physical significance, is given in section 7.2. A general analysis of helical sideband equilibria, along with a detailed description of the Elmo bumpy torus, is presented in sections 7.3 and 7.4. A general description of toroidal dipole-current equilibria, including a detailed discussion of stellarators, heliotrons, and torsatrons, is given in sections 7.5 and 7.6

  5. Three-dimensional aromatic networks.

    Science.gov (United States)

    Toyota, Shinji; Iwanaga, Tetsuo

    2014-01-01

    Three-dimensional (3D) networks consisting of aromatic units and linkers are reviewed from various aspects. To understand principles for the construction of such compounds, we generalize the roles of building units, the synthetic approaches, and the classification of networks. As fundamental compounds, cyclophanes with large aromatic units and aromatic macrocycles with linear acetylene linkers are highlighted in terms of transannular interactions between aromatic units, conformational preference, and resolution of chiral derivatives. Polycyclic cage compounds are constructed from building units by linkages via covalent bonds, metal-coordination bonds, or hydrogen bonds. Large cage networks often include a wide range of guest species in their cavity to afford novel inclusion compounds. Topological isomers consisting of two or more macrocycles are formed by cyclization of preorganized species. Some complicated topological networks are constructed by self-assembly of simple building units.

  6. Three dimensional imaging of otoliths

    International Nuclear Information System (INIS)

    Barry, B.; Markwitz, A.; David, B.

    2008-01-01

    Otoliths are small structures in fish ears made of calcium carbonate which carry a record of the environment in which the fish live. Traditionally, in order to study their microchemistry by a scanning technique such as PIXE the otoliths have been either ground down by hand or thin sectioned to expose the otolith core. However this technique is subject to human error in judging the core position. In this study we have scanned successive layers of otoliths 50 and 100 μm apart by removing the otolith material in a lapping machine which can be set to a few μm precision. In one study by comparing data from otoliths from the two ears of a freshwater species we found that polishing by hand could miss the core and thus give misleading results as to the life cycle of the fish. In another example we showed detail in a marine species which could be used to build a three dimensional picture of the Sr distribution. (author)

  7. Three-Dimensional Rebar Graphene.

    Science.gov (United States)

    Sha, Junwei; Salvatierra, Rodrigo V; Dong, Pei; Li, Yilun; Lee, Seoung-Ki; Wang, Tuo; Zhang, Chenhao; Zhang, Jibo; Ji, Yongsung; Ajayan, Pulickel M; Lou, Jun; Zhao, Naiqin; Tour, James M

    2017-03-01

    Free-standing robust three-dimensional (3D) rebar graphene foams (GFs) were developed by a powder metallurgy template method with multiwalled carbon nanotubes (MWCNTs) as a reinforcing bar, sintered Ni skeletons as a template and catalyst, and sucrose as a solid carbon source. As a reinforcement and bridge between different graphene sheets and carbon shells, MWCNTs improved the thermostability, storage modulus (290.1 kPa) and conductivity (21.82 S cm -1 ) of 3D GF resulting in a high porosity and structurally stable 3D rebar GF. The 3D rebar GF can support >3150× the foam's weight with no irreversible height change, and shows only a ∼25% irreversible height change after loading >8500× the foam's weight. The 3D rebar GF also shows stable performance as a highly porous electrode in lithium ion capacitors (LICs) with an energy density of 32 Wh kg -1 . After 500 cycles of testing at a high current density of 6.50 mA cm -2 , the LIC shows 78% energy density retention. These properties indicate promising applications with 3D rebar GFs in devices requiring stable mechanical and electrochemical properties.

  8. Effect of intertrochanteric osteotomy on the proximal femur of rabbits: assessment with power Doppler sonography and scintigraphy Efeito da osteotomia intertrocantérica no femur proximal de coelhos: avaliação com utra-sonografia power Doppler e cintilografia

    Directory of Open Access Journals (Sweden)

    Andrea S. Doria

    2007-01-01

    Full Text Available OBJECTIVE: In bone injury, repair results in local increased vascularity and bone marrow remodeling. Characterizing the vascular and metabolic imaging patterns of the proximal femur following an intertrochanteric osteotomy may help clinicians decide proper management of the patient. Our objective was to measure Doppler sonography and scintigraphy interval changes in the proximal femur following intertrochanteric osteotomy and compare imaging and histomorphometric measurements in the late post-operative stage (6 weeks after surgery in a rabbit model of bone injury. MATERIALS AND METHODS: Both hips of 12 adult rabbits were imaged with power Doppler sonography and scintigraphy prior to and after (7 days and 6 weeks unilateral osteotomy. Accuracy of the imaging methods was evaluated using hip operative status and histomorphometric results (vascular fractional area and number of vessels per area unit as reference standard measures. RESULTS: A significant difference in the mean number of pixels was noted between operated and non-operated femura in late post-operative power Doppler examinations (P=0.049. Although without reaching statistical significance, the AUC of Doppler measurements (AUC=0.99 was numerically greater than the AUC of scintigraphy measurements (AUC=0.857±0.099 (P=0.15 in differentiating proximal femura with regard to their fractional vascular areas in the late post-operative stage. In contrast, scintigraphy tended to perform better (AUC=0.984±0.022 than Doppler ultrasound (AUC=0.746±0.131 to demonstrate the vascularity intensity per area unit (P=0.07 in the late stage. CONCLUSION: Our results warrant further investigation to determine the value of different imaging modalities for assessment of pathologic changes following hip surgery. Power Doppler sonography demonstrated larger AUCs (representing higher accuracy for the discrimination of vascular fractional areas and scintigraphy, for discrimination of the number of vessels per

  9. Elastocapillary fabrication of three-dimensional microstructures

    NARCIS (Netherlands)

    van Honschoten, J.W.; Berenschot, Johan W.; Ondarcuhu, T.; Sanders, Remco G.P.; Sundaram, J.; Elwenspoek, Michael Curt; Tas, Niels Roelof

    2010-01-01

    We describe the fabrication of three-dimensional microstructures by means of capillary forces. Using an origami-like technique, planar silicon nitride structures of various geometries are folded to produce three-dimensional objects of 50–100 m. Capillarity is a particularly effective mechanism since

  10. THREE-DIMENSIONAL ULTRASOUND AND STENOSIS OF INTERNAL CAROTID ARTERY

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2003-12-01

    Full Text Available Background. Elucidation of the ultrasound structure of the atherosclerotic plaque in stenosis of internal carotid artery may have important implications for carotid surgery. This study compares the ability of computer derived 3D ultrasound gray scale volumetric measurements to diferentiate between ultrasonic structure of symptomatic and asymptomatic carotid plaque causing more than 70% stenosis.Methods. Eightysix internal carotid artery stenoses (70–99%, 45 symptomatic, 41 asymptomatic were imaged with 3D ultrasound to obtain the whole volume of the atherosclerotic plaque. Digitalized sonograms were computerized and normalized to the gray scale median (GSM of blood (0 and vessel adventitia (200. Plaque GSM was obtained for the whole volume by computing the volume ratio between echolucent and echogenic areas. The plaque heterogeneity was obtained by computing the density of echogenic areas per volume unit. Parametric t test was used for statistic analysis.Results. Minimum volume GSM ratio (determining echolucency was higher for asymptomatic plaque (0.6 – CI 0.48– 0.91 versus 0.3 – CI 0.21–0.75: p = 0.002. Greater GSM heterogeneity was present in symptomatic plaque (6.8 – CI 2.5– 18.3 versus 0.41 – CI 0.2–3.4;.p = 0.0001.Conclusions. Volume ultrasound imaging that enables objective assessment of whole ultrasonic plaque structure is more sensitive that single longitudinal view sonography for differentiating between ultrasonic structure of symptomatic and asymptomatic plaque.

  11. Three dimensional visualization of medical images

    International Nuclear Information System (INIS)

    Suto, Yasuzo

    1992-01-01

    Three dimensional visualization is a stereoscopic technique that allows the diagnosis and treatment of complicated anatomy site of the bone and organ. In this article, the current status and technical application of three dimensional visualization are introduced with special reference to X-ray CT and MRI. The surface display technique is the most common for three dimensional visualization, consisting of geometric model, voxel element, and stereographic composition techniques. Recent attention has been paid to display method of the content of the subject called as volume rendering, whereby information on the living body is provided accurately. The application of three dimensional visualization is described in terms of diagnostic imaging and surgical simulation. (N.K.)

  12. three dimensional photoelastic investigations on thick rectangular

    African Journals Online (AJOL)

    user

    1983-09-01

    Sep 1, 1983 ... Thick rectangular plates are investigated by means of three-dimensional photoelasticity ... a thin plate theory and a higher order thick plate theory. 1. ..... number of fringes lest the accuracy of the results will be considerably.

  13. Three dimensional diffusion calculations of nuclear reactors

    International Nuclear Information System (INIS)

    Caspo, N.

    1981-07-01

    This work deals with the three dimensional calculation of nuclear reactors using the code TRITON. The purposes of the work were to perform three-dimensional computations of the core of the Soreq nuclear reactor and of the power reactor ZION and to validate the TRITON code. Possible applications of the TRITON code in Soreq reactor calculations and in power reactor research are suggested. (H.K.)

  14. Three-dimensional effects in fracture mechanics

    International Nuclear Information System (INIS)

    Benitez, F.G.

    1991-01-01

    An overall view of the pioneering theories and works, which enlighten the three-dimensional nature of fracture mechanics during the last years is given. the main aim is not an exhaustive reviewing but the displaying of the last developments on this scientific field in a natural way. This work attempts to envisage the limits of disregarding the three-dimensional behaviour in theories, analyses and experiments. Moreover, it tries to draw attention on the scant fervour, although increasing, this three-dimensional nature of fracture has among the scientific community. Finally, a constructive discussion is presented on the use of two-dimensional solutions in the analysis of geometries which bear a three-dimensional configuration. the static two-dimensional solutions and its applications fields are reviewed. also, the static three-dimensional solutions, wherein a comparative analysis with elastoplastic and elastostatic solutions are presented. to end up, the dynamic three-dimensional solutions are compared to the asymptotic two-dimensional ones under the practical applications point of view. (author)

  15. Three-dimensional microbubble streaming flows

    Science.gov (United States)

    Rallabandi, Bhargav; Marin, Alvaro; Rossi, Massimiliano; Kaehler, Christian; Hilgenfeldt, Sascha

    2014-11-01

    Streaming due to acoustically excited bubbles has been used successfully for applications such as size-sorting, trapping and focusing of particles, as well as fluid mixing. Many of these applications involve the precise control of particle trajectories, typically achieved using cylindrical bubbles, which establish planar flows. Using astigmatic particle tracking velocimetry (APTV), we show that, while this two-dimensional picture is a useful description of the flow over short times, a systematic three-dimensional flow structure is evident over long time scales. We demonstrate that this long-time three-dimensional fluid motion can be understood through asymptotic theory, superimposing secondary axial flows (induced by boundary conditions at the device walls) onto the two-dimensional description. This leads to a general framework that describes three-dimensional flows in confined microstreaming systems, guiding the design of applications that profit from minimizing or maximizing these effects.

  16. Towards three-dimensional optical metamaterials

    Science.gov (United States)

    Tanaka, Takuo; Ishikawa, Atsushi

    2017-12-01

    Metamaterials have opened up the possibility of unprecedented and fascinating concepts and applications in optics and photonics. Examples include negative refraction, perfect lenses, cloaking, perfect absorbers, and so on. Since these metamaterials are man-made materials composed of sub-wavelength structures, their development strongly depends on the advancement of micro- and nano-fabrication technologies. In particular, the realization of three-dimensional metamaterials is one of the big challenges in this research field. In this review, we describe recent progress in the fabrication technologies for three-dimensional metamaterials, as well as proposed applications.

  17. Development of three dimensional solid modeler

    International Nuclear Information System (INIS)

    Zahoor, R.M.A.

    1999-01-01

    The work presented in this thesis is aimed at developing a three dimensional solid modeler employing computer graphics techniques using C-Language. Primitives have been generated, by combination of plane surfaces, for various basic geometrical shapes including cylinder, cube and cone. Back face removal technique for hidden surface removal has also been incorporated. Various transformation techniques such as scaling, translation, and rotation have been included for the object animation. Three dimensional solid modeler has been created by the union of two primitives to demonstrate the capabilities of the developed program. (author)

  18. Three-dimensional topological insulators and bosonization

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Andrea [INFN, Sezione di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Randellini, Enrico [INFN, Sezione di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Sisti, Jacopo [Scuola Internazionale Superiore di Studi Avanzati (SISSA),Via Bonomea 265, 34136 Trieste (Italy)

    2017-05-25

    Massless excitations at the surface of three-dimensional time-reversal invariant topological insulators possess both fermionic and bosonic descriptions, originating from band theory and hydrodynamic BF theory, respectively. We analyze the corresponding field theories of the Dirac fermion and compactified boson and compute their partition functions on the three-dimensional torus geometry. We then find some non-dynamic exact properties of bosonization in (2+1) dimensions, regarding fermion parity and spin sectors. Using these results, we extend the Fu-Kane-Mele stability argument to fractional topological insulators in three dimensions.

  19. Three-dimensional imaging utilizing energy discrimination

    International Nuclear Information System (INIS)

    Gunter, D.L.; Hoffman, K.R.; Beck, R.N.

    1990-01-01

    An algorithm is proposed for three-dimensional image reconstruction in nuclear medicine which uses scattered radiation rather than multiple projected images to determine the source depth within the body. Images taken from numerous energy windows are combined to construct the source distribution in the body. The gamma-ray camera is not moved during the imaging process. Experiments with both Tc-99m and Ga-67 demonstrate that two channels of depth information can be extracted from the low energy images produced by scattered radiation. By combining this technique with standard SPECT reconstruction using multiple projections the authors anticipate much improved spatial resolution in the overall three-dimensional reconstruction

  20. Transcranial sonography on Parkinson′s disease and essential tremor

    Directory of Open Access Journals (Sweden)

    Ahmad Chitsaz

    2013-01-01

    Full Text Available Background: The study on transcranial sonocraphy (TCS as a diagnostic test for Parkinson′s disease (PD has been neglected in some hospitals. The current study was conducted as the first study to investigate the utility of TCS for diagnosis of PD and its ability to distinguish PD from essential tremor (ET in an Iranian population. Materials and Methods: TCS of substantia nigra (SN was performed on 50 PD, 48 ET, and 50 healthy controls by two blinded investigators. Results: Bilateral SN margin over 0.20 cm 2 was found in 39 (90% and 7 (15% in PD and ET patients, respectively. Furthermore, 4 (8% of healthy control displayed this particular echo feature as well (false positives. SN hyperechogenicity ≥0.20 cm 2 was considered as a cut-off point to detected PD. Accordingly, TCS proved 90% (95% confidence interval [CI]: 77.85-97.35 sensitive and 92% ( 95% CI: 80.75-97.73 specific for the detection of PD by visualizing the SN. Conclusion: SN hyperechogenicity ≥20 cm 2 is a specific feature of PD. Since, the symptoms of PD and ET might be overlapping; this method seems to be reliable to confirm PD diagnosis in doubtful clinical cases. Further studies in years to come are warranted to shed light on standardized data for Iranian to enhance the validity of TCS.

  1. Problem in twin pregnancy: Findings of prenatal sonography and autopsy

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Cho, Jeong Yeon; Song, Mi Jin; Min, Jee Yeon; Lee, Young Ho; Lee, Hak Jong; Chun, Yi Kyeong; Kim, Yee Jeong; Hong, Sung Ran

    2001-01-01

    Multifetal gestations are high risk pregnancies with higher perinatal morbidity and mortality. Multifetal gestations are subject to unique complications including conjoined twins, twin-to-twin transfusion syndrome (TTTS), acardiac twins, twin embization of co-twin demise and heterotopic pregnancies. Prenatal sonographic diagnosis of types and complications of multifetal gestations is important for antenatal care and prediction of fetal outcome. This study was performed to present the prenatal ultrasonographic findings and pathologic findings of the unique complications of twin pregnancy. Acardia is a lethal anomaly occurring in 1% of monozygotic twin. The acardiac twin has a parasitic existence and depends on the donor (pump) twin for its blood supply via placental anastomoses and retrograde perfusion of umbilical cord. This twin reversed arterial perfusion (TRAP) sequence is a most extreme manifestation on the TTTS. Doppler verification reversed flow in umbilical cord of the acardiac twin confirms the diagnosis.

  2. Sonography and computed tomography of splenic nonsystemic lesions

    International Nuclear Information System (INIS)

    Garretti, L.; Cassinis, M.C.; Gandini, G.

    1987-01-01

    Differential diagnosis problems are caused by the increased, at time occasional detection of benignant and malignant spleen focal lesions in routine superior abdomen ultrasound (US). The following pathologic conditions were reported in 29 patients with focal lesions (excepted systemic diseases): 6 plain cysts, 1 cystic lymphangioma, 3 echinococcus cysts, 3 abscesses, 7 hematomas and 9 metastases. US examination and clinical data together have permitted the differentiation of cysts from solid nodules but has limits in the characterzation of lesions and in the diagnosis of abscesses. Metastases did non present specific US or CT aspects and have been correctly charaterized only with aid of anamnestical data and for the coexhistence of hepatic lesions. CT has proven superior specificity, compared to US, only in the diagnosis of abscesses and should thus be utilized only in selected cases

  3. Analysis of abnormally thickened endometrial patterns on transvaginal sonography

    International Nuclear Information System (INIS)

    Lee, Myung Sook; Cho, Hyeun Cha

    1999-01-01

    To determine whether the transvaginal sonographic appearance of the thickened endometrium can help to predict the underlying endometrial pathologic process. The sonogram reports of fall 41 pre- and 21 postmenopausal women who underwent transvaginal sonogram were retrospectively analyzed. The women undergoing estrogen replacement therapy, tamoxifen therapy or having abnormal cervical cytology were excluded from this study. The analysis of sonographic and histologic results was performed in all patients. Three distinct sonographic patterns were encountered. Type I consisted of heterogeneous endometrial thickening with internal hypoechoic areas (normal [n=4], polyp [n=1] and cancer [n=4] in premenopausal women and cancer [n=4] in postmenopausal women). Type II consisted of echogenic endometrial thickening with or without tiny cysts (normal[n=5], and hyperplasia [n=7] in premenopausal women and normal [n=4], polyp [n=2], and hyperplasia [n=1] in postmenopausal women). Type III consisted of localized well defined endoluminal lesion (normal [n=1], polyp [n=14], hyperplasia [n=1], cancer [n=1], and submucosal mass [n=3] in premenopausal women and normal [n=4], polyp [n=2],submucosal mass [n=3], and hematoma [n=1] in postmenopausal women). The measurement of the endometrial thickness combined with analysis of sonographic echo patterns may be helpful in prediction and differentiation of endometrial disease in pre- and postmenopausal women. Also it can contribute to avoiding unnecessary D and C.

  4. Value of modern sonography in the assessment of meniscal lesions

    International Nuclear Information System (INIS)

    Wareluk, Pawel; Szopinski, Kazimierz T.

    2012-01-01

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries

  5. Tissue reactions of abdominal integuments to surgical sutures in sonography

    Directory of Open Access Journals (Sweden)

    Andrzej Smereczyński

    2014-03-01

    Full Text Available Classical abdominal surgeries usually require long incisions of the abdominal integuments followed by tight closure with adequate suturing material. Nonabsorbable sutures may cause various reactions, including granuloma reactions, both sterile and inflammatory. The aim of the study was to analyze prospective ultrasound examinations of the abdominal integuments in order to detect tissue reactions to surgical sutures. Material and methods: For 10 years, ultrasound examinations of the abdominal integuments involved the assessment of surgical scars in all patients who underwent open or closed surgeries for various reasons (in total 2254 patients. Ultrasound examinations were performed only with the use of linear probes with the frequency ranging from 7 to 12 MHz. Each scar in the abdominal integuments was scanned in at least two planes. When a lesion was detected, the image was enlarged and the transducer was rotated by approximately 180° in order to capture the dimensions of the granuloma and the most characteristic image of the suture. Moreover, vascularization of the lesion was also assessed with the use of color Doppler mode set to detect the lowest flows. Results: All granulomas (19 lesions, two in one patient created hypoechoic oval or round nodules, were relatively well-circumscribed and their size ranged from 8 × 4 mm to 40 × 14 mm. In the center of the lesion, it was possible to notice a thread that was coiled to various degrees and presented itself as a double, curved hyperechoic line. In 9 out of 19 granulomas, slight peripheral vascularization was observed. The substantial majority of the lesions (n = 15 were in contact with the fascia. In seven patients, compression with the transducer induced known local pain (n = 4 or intensified pain that had already been present (n = 3; all of these granulomas infiltrated the fascia and showed slight peripheral vascularization. Cutaneous fistulae developed in two patients with purulent reactions to the running stitch (in one patient – two fistulae. Conclusions: Suture granulomas in the abdominal integuments manifest themselves as nodular hypoechoic lesions, usually localized at the edge of the fascia – subcutaneous fat. A pathognomonic sign of this type of granulomas is the presence of a thread in their center that usually manifests itself as a chaotically shaped, double hyperechoic line. In some granulomas, particularly those with clinical presentation, slight peripheral vascularization is observed.

  6. Sonography and cytology in the evaluation of salivary gland masses

    International Nuclear Information System (INIS)

    Gozzi, G.; Bazzochi, M.; Vasciaveo, A.; Bassini, A.; Bellis, G.B.; Di Bonito, L.

    1991-01-01

    The contribution of the combined use of US and cytology is evaluated in the diagnosis of masses in yhe salivary glands and adjacent structures. US had 87.2% sensitivity in locating the mass; its accuracy in defining both phisical structure and benign/malignant nature of the lesion was 91% and 74% respectively. Thus US, after demonstrating a lesion, does not always allow the exact definition of its characteristic. In many of these cases, other imaging modalities do not help either. In our series of cases, cytology allowed an unquestionable diagnosis to be made in 87.2% of cases, and the combined use of US and cytology rose the figure to 97%. The only limitation is the evaluation of the deep extent of large masses: in such cases CT or, if available, MR imaging are recommended

  7. High-resolution sonography in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Solbiati, L.; De Pra, L.; Rizzatto, G.; Derchi, L.E.

    1986-01-01

    Carpal tunnel syndrome, caused by the compression on the median nerve under the transverse carpal ligament, has multiple causes and clinical presentations. One hundred eighteen patients with carpal tunnel sydrome underwent high-resolution US which demonstrated unpalpable cystic masses in 25 patients (lobulated stalked synovial cysts in 19 and retrotendinous cysts in six, all confirmed at surgery), and diffuse thickening and decreased echogenicity of the tendon sheaths in 87 patients, suggesting tenosynovitis (confirmed at surgery in 64). In six patients simple encasement of muscle bellies in the carpal tunnel was shown. US can delineate the cause of carpal tunnel syndrome, suggest the need for surgery, and aid the surgeon in locating the lesion to be removed

  8. Fibrocystic disease of breast: variable mammographic and sonography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, the echogenicity was variable; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical mammographic and/or sonographic evidence of fibroadenoma or carcinoma is not present

  9. Fibrocystic disease of breast: variable mammographic and sonography appearance

    International Nuclear Information System (INIS)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye

    1993-01-01

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, theechogenicity was variable ; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical mammographic and/or sonographic evidence of fibroadenoma or carcinoma is not present

  10. The Use of Sonography and Mammography in the Evaluation of ...

    African Journals Online (AJOL)

    If you would like more information about how to print, save, and work with PDFs, Highwire Press provides a helpful Frequently Asked Questions about PDFs. Alternatively, you can download the PDF file directly to your computer, from where it can be opened using a PDF reader. To download the PDF, click the Download link ...

  11. Value of modern sonography in the assessment of meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wareluk, Pawel, E-mail: pwareluk@wum.edu.pl [Department of Diagnostic Imaging, Second Faculty of Medicine, Medical University of Warsaw, ul. Kondratowicza 8, 03-242 Warsaw (Poland); Szopinski, Kazimierz T., E-mail: kszopinski@wum.edu.pl [Department of Dental and Maxillofacial Radiology, First Faculty of Medicine, Medical University of Warsaw, ul. Nowogrodzka 59, 02-006 Warsaw (Poland)

    2012-09-15

    The aim of this prospective study was to assess the accuracy of modern ultrasonography in diagnostic imaging of meniscal tears. One hundred and sixty menisci were evaluated in 80 patients (42 females, 38 males, mean age = 36.2 years, range = 16–70 years). Inclusion criteria for the study were twofold: clinical suspicion of meniscal injury and clinical indication for arthroscopy. Knee examination was performed with the Voluson 730 Expert ultrasound system (General Electric). After sonographic examination, all patients underwent arthroscopic procedures within 1–4 days. The final diagnosis of meniscal tears was taken from surgical reports. The overall sensitivity, specificity, positive predictive value and negative predictive value of sonographic examination in the assessment of meniscal tears amounted to 85.4%, 85.7%, 67.3% and 94.4%, respectively. The statistical parameters were not statistically different in medial and lateral menisci. Age, sex, body mass index (BMI), weight, physical activity, mechanism on injury, and time lapse from injury did not have a statistically significant impact on the usefulness of ultrasonography. The highest sensitivity (>90%) was obtained in medial menisci and in patients with a BMI > 25. The highest specificity (>90%) was obtained in lateral menisci, in patients after twisting injuries, in sports injuries, and in recent injuries (time lapse from the injury <1 month). The positive predictive value (PPV) of sonographic examination was higher than 90% only in recent injuries (<1 month), however, the negative predictive value of ultrasound is high, being less than 90% in males with lesions of lateral menisci and in sequelae of sports injuries.

  12. Sonography of the iliotibial band: spectrum of findings

    Directory of Open Access Journals (Sweden)

    Carlos Frederico Arend

    2014-02-01

    Full Text Available Iliotibial band lesions constitute a potential source of discomfort and are frequently confounded with other conditions which cause pain on the lateral aspect of the hip, thigh and knee. Ultrasonography is usually regarded as a first-line imaging modality in the assessment of such conditions because of its excellent diagnostic accuracy, low cost and wide availability. The correct identification of the structure involved in the production of symptoms leads to an appropriate management and to a higher probability of resolution of the clinical complaint. The present article is aimed at reviewing the different sonographic presentations of iliotibial band syndromes.

  13. Blunt abdominal trauma: The role of focused abdominal sonography ...

    African Journals Online (AJOL)

    Samer Malak Boutros

    2015-02-28

    Feb 28, 2015 ... contrast material hinders the use of CT in evaluation of some trauma patients. A noncontrast study diminishes the sensitivity of CT in diagnosis of solid organ injuries.6. CT disadvantages include the need for patient transfer to the CT unit, hazards of ionizing radiation or if contrast media is used, patients may ...

  14. Expectant mothers' perception of prenatal sonography in a South ...

    African Journals Online (AJOL)

    The questionnaire contained a total of 17 questions consisting of 16 close‑ended questions .... pregnant women, which helps to stimulate a parental bond with the foetus and ... patient perception, awareness, expectations and experiences.

  15. Microembolus Detection by Transcranial Doppler Sonography: Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vlasta Vuković-Cvetković

    2012-01-01

    Full Text Available Transcranial Doppler can detect microembolic signals which are characterized by unidirectional high intensity increase, short duration, random occurrence, and a “whistling” sound. Microembolic signals have been detected in a number of clinical settings: carotid artery stenosis, aortic arch plaques, atrial fibrillation, myocardial infarction, prosthetic heart valves, patent foramen ovale, valvular stenosis, during invasive procedures (angiography, percutaneous transluminal angioplasty, surgery (carotid, cardiopulmonary bypass, orthopedic, and in certain systemic diseases. Microembolic signals are frequent in large artery disease, less commonly detected in cardioembolic stroke, and infrequent in lacunar stroke. This article provides an overview about the current state of technical and clinical aspects of microembolus detection.

  16. The role of 3-dimensional sonography and virtual sonographic ...

    African Journals Online (AJOL)

    A.M. Tawfeek

    2017-12-06

    Dec 6, 2017 ... 85.7%; positive predictive values were 96.5%; negative predictive value were 85.7%. .... dence of urinary tract injury or infection; suspicious lesions or ..... dimensional ultrasound in the pediatric urinary tract: pictorial demon-.

  17. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    Bierma-Zeinstra, S. M.; Bohnen, A. M.; Verhaar, J. A.; Prins, A.; Ginai-Karamat, A. Z.; Laméris, J. S.

    2000-01-01

    To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. Patients (n = 224) aged 50 years or older with hip pain, referred by the general practitioner for radiological investigation, underwent a

  18. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    S.M. Bierma-Zeinstra (Sita); A.M. Bohnen (Arthur); J.A.N. Verhaar (Jan); A. Prins (Ad); J.S. Lameris; A.Z. Ginai (Abida)

    2000-01-01

    textabstractOBJECTIVE: To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. METHODS: Patients (n = 224) aged 50 years or older with hip pain, referred by the general

  19. Three-Dimensional Messages for Interstellar Communication

    Science.gov (United States)

    Vakoch, Douglas A.

    One of the challenges facing independently evolved civilizations separated by interstellar distances is to communicate information unique to one civilization. One commonly proposed solution is to begin with two-dimensional pictorial representations of mathematical concepts and physical objects, in the hope that this will provide a foundation for overcoming linguistic barriers. However, significant aspects of such representations are highly conventional, and may not be readily intelligible to a civilization with different conventions. The process of teaching conventions of representation may be facilitated by the use of three-dimensional representations redundantly encoded in multiple formats (e.g., as both vectors and as rasters). After having illustrated specific conventions for representing mathematical objects in a three-dimensional space, this method can be used to describe a physical environment shared by transmitter and receiver: a three-dimensional space defined by the transmitter--receiver axis, and containing stars within that space. This method can be extended to show three-dimensional representations varying over time. Having clarified conventions for representing objects potentially familiar to both sender and receiver, novel objects can subsequently be depicted. This is illustrated through sequences showing interactions between human beings, which provide information about human behavior and personality. Extensions of this method may allow the communication of such culture-specific features as aesthetic judgments and religious beliefs. Limitations of this approach will be noted, with specific reference to ETI who are not primarily visual.

  20. Three-Dimensional Printing Surgical Applications.

    Science.gov (United States)

    AlAli, Ahmad B; Griffin, Michelle F; Butler, Peter E

    2015-01-01

    Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice.

  1. Electron crystallography of three dimensional protein crystals

    NARCIS (Netherlands)

    Georgieva, Dilyana

    2008-01-01

    This thesis describes an investigation of the potential of electron diffraction for studying three dimensional sub-micro-crystals of proteins and pharmaceuticals. A prerequisite for using electron diffraction for structural studies is the predictable availability of tiny crystals. A method for

  2. Three dimensional electrochemical system for neurobiological studies

    DEFF Research Database (Denmark)

    Vazquez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    In this work we report a novel three dimensional electrode array for electrochemical measurements in neuronal studies. The main advantage of working with these out-of-plane structures is the enhanced sensitivity of the system in terms of measuring electrochemical changes in the environment...

  3. Imaging unsteady three-dimensional transport phenomena

    Indian Academy of Sciences (India)

    2014-01-05

    Jan 5, 2014 ... The image data can be jointly analysed with the physical laws governing transport and principles of image formation. Hence, with the experiment suitably carried out, three-dimensional physical domains with unsteady processes can be accommodated. Optical methods promise to breach the holy grail of ...

  4. Computerized three-dimensional normal atlas

    International Nuclear Information System (INIS)

    Mano, Isamu; Suto, Yasuzo; Suzuki, Masataka; Iio, Masahiro.

    1990-01-01

    This paper presents our ongoing project in which normal human anatomy and its quantitative data are systematically arranged in a computer. The final product, the Computerized Three-Dimensional Normal Atlas, will be able to supply tomographic images in any direction, 3-D images, and coded information on organs, e.g., anatomical names, CT numbers, and T 1 and T 2 values. (author)

  5. Three-Dimensional Shallow Water Acoustics

    Science.gov (United States)

    2016-03-30

    medium properties, so horizontal refraction and reflection of sound can occur and produce significant three-dimensional (3-D) sound propagation ...by the environmental factors existing commonly in the continental shelf and shelfbreak areas, such as slopes, submarine canyons, sub-bottom layers ...surface waves, internal waves and shelfbreak fronts. 15. SUBJECT TERMS Continental Shelf; 3-D Acoustics , Surface Waves, Sound Propagation 16

  6. Three-dimensional ultrasound in the diagnosis of Müllerian duct anomalies and concordance with magnetic resonance imaging.

    Science.gov (United States)

    Bermejo, C; Martínez Ten, P; Cantarero, R; Diaz, D; Pérez Pedregosa, J; Barrón, E; Labrador, E; Ruiz López, L

    2010-05-01

    To demonstrate the value of three-dimensional (3D) ultrasound in the diagnosis of uterine malformations and its concordance with magnetic resonance imaging (MRI). This study included 286 women diagnosed with uterine malformation by 3D ultrasound, having been referred to our clinics on suspicion of uterine malformation following clinical and/or conventional two-dimensional ultrasound examination. With the exception of three with intact hymen, patients underwent both bimanual examination and speculoscopy before and/or after sonography. MRI was performed in 65 cases. We analyzed the diagnostic concordance between the techniques in the study of uterine malformations. Using 3D ultrasound we diagnosed: one case with uterine agenesis; 10 with unicornuate uterus, four of which also underwent MRI; six with didelphic uterus, one of which had MRI; 45 with bicornuate uterus, 12 of which had MRI; 125 with septate uterus (18 with two cervices), 42 of which had MRI (six with two cervices); 96 with arcuate uterus, three of which had MRI; and three with diethylstilbestrol (DES) iatrogenic uterine malformations, all of which had MRI. Among the 65 which underwent MRI, the diagnosis was: four cases with unicornuate uterus, 10 with bicornuate uterus (two with two cervices), 45 with septate uterus (five with two cervices), three with arcuate uterus and three with DES-related uterine malformations. The concordance between 3D ultrasound and MRI was very good (kappa index, 0.880 (95% CI, 0.769-0.993)). Discrepancies in diagnosis between the two techniques occurred in four cases. There was very good concordance in the diagnosis of associated findings (kappa index, 0.878 (95% CI, 0.775-0.980)), this analysis identifying differences in two cases. There is a high degree of concordance between 3D ultrasound and MRI in the diagnosis of uterine malformations, the relationship between cavity and fundus being visualized equally well with both techniques. 3D ultrasound should be complemented by

  7. Arching in three-dimensional clogging

    Science.gov (United States)

    Török, János; Lévay, Sára; Szabó, Balázs; Somfai, Ellák; Wegner, Sandra; Stannarius, Ralf; Börzsönyi, Tamás

    2017-06-01

    Arching in dry granular material is a long established concept, however it remains still an open question how three-dimensional orifices clog. We investigate by means of numerical simulations and experimental data how the outflow creates a blocked configuration of particles. We define the concave surface of the clogged dome by two independent methods (geometric and density based). The average shape of the cupola for spheres is almost a hemisphere but individual samples have large holes in the structure indicating a blocked state composed of two-dimensional force chains rather than three-dimensional objects. The force chain structure justifies this assumption. For long particles the clogged configurations display large variations, and in certain cases the empty region reaches a height of 5 hole diameters. These structures involve vertical walls consisting of horizontally placed stable stacking of particles.

  8. Three-dimensional bio-printing.

    Science.gov (United States)

    Gu, Qi; Hao, Jie; Lu, YangJie; Wang, Liu; Wallace, Gordon G; Zhou, Qi

    2015-05-01

    Three-dimensional (3D) printing technology has been widely used in various manufacturing operations including automotive, defence and space industries. 3D printing has the advantages of personalization, flexibility and high resolution, and is therefore becoming increasingly visible in the high-tech fields. Three-dimensional bio-printing technology also holds promise for future use in medical applications. At present 3D bio-printing is mainly used for simulating and reconstructing some hard tissues or for preparing drug-delivery systems in the medical area. The fabrication of 3D structures with living cells and bioactive moieties spatially distributed throughout will be realisable. Fabrication of complex tissues and organs is still at the exploratory stage. This review summarize the development of 3D bio-printing and its potential in medical applications, as well as discussing the current challenges faced by 3D bio-printing.

  9. Three dimensional imaging in cardiac nuclear medicine

    International Nuclear Information System (INIS)

    Torizuka, Kanji; Ishii, Yasushi; Yonekura, Yoshiharu; Yamamoto, Kazutaka; Tamaki, Takeyoshi

    1981-01-01

    Methods to obtain three dimensional images of the heart were reviewed. Gated three dimensional display reconstructed from images using bidirectional collimator, was a useful method to detect akinesis of the heart wall. Tomographic observation of the heart can be carried out by a pinhole collimator to image ischemia with high sensitivity. However the focusing plane must be carefully selected to prevent false positives. In the case of emission CT (ECT), utilization of positron emitters gave a quantitative image without correction, whereas single photon ECT needed the correction due to the absorption of γ-ray. Though the reliability of the images by ECT was high, the time required for data acquisition was much longer than that by a 7 pinhole or bidirectional collimator. (Nakanishi, T.)

  10. Three dimensional transport model for toroidal plasmas

    International Nuclear Information System (INIS)

    Copenhauer, C.

    1980-12-01

    A nonlinear MHD model, developed for three-dimensional toroidal geometries (asymmetric) and for high β (β approximately epsilon), is used as a basis for a three-dimensional transport model. Since inertia terms are needed in describing evolving magnetic islands, the model can calculate transport, both in the transient phase before nonlinear saturation of magnetic islands and afterwards on the resistive time scale. In the β approximately epsilon ordering, the plasma does not have sufficient energy to compress the parallel magnetic field, which allows the Alfven wave to be eliminated in the reduced nonlinear equations, and the model then follows the slower time scales. The resulting perpendicular and parallel plasma drift velocities can be identified with those of guiding center theory

  11. Three dimensional digital imaging of environmental data

    International Nuclear Information System (INIS)

    Nichols, R.L.; Eddy, C.A.

    1991-01-01

    The Environmental Sciences Section (ESS) of the Savannah River Laboratory has recently acquired the computer hardware (Silicon Graphics Personal Iris Workstations) and software (Dynamic Graphics, Interactive Surface and Volume Modeling) to perform three dimensional analysis of hydrogeologic data. Three dimensional digital imaging of environmental data is a powerful technique that can be used to incorporate field, analytical, and modeling results from geologic, hydrologic, ecologic, and chemical studies into a comprehensive model for visualization and interpretation. This report covers the contamination of four different sites of the Savannah River Plant. Each section of this report has a computer graphic display of the concentration of contamination in the groundwater and/or sediments of each site

  12. SNAP - a three dimensional neutron diffusion code

    International Nuclear Information System (INIS)

    McCallien, C.W.J.

    1993-02-01

    This report describes a one- two- three-dimensional multi-group diffusion code, SNAP, which is primarily intended for neutron diffusion calculations but can also carry out gamma calculations if the diffusion approximation is accurate enough. It is suitable for fast and thermal reactor core calculations and for shield calculations. SNAP can solve the multi-group neutron diffusion equations using finite difference methods. The one-dimensional slab, cylindrical and spherical geometries and the two-dimensional case are all treated as simple special cases of three-dimensional geometries. Numerous reflective and periodic symmetry options are available and may be used to reduce the number of mesh points necessary to represent the system. Extrapolation lengths can be specified at internal and external boundaries. (Author)

  13. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  14. Three-dimensional imaging modalities in endodontics

    Science.gov (United States)

    Mao, Teresa

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome. PMID:25279337

  15. Three-dimensional imaging modalities in endodontics

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Teresa; Neelakantan, Prasanna [Dept. of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha University, Chennai (India)

    2014-09-15

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  16. Three-dimensional imaging modalities in endodontics

    International Nuclear Information System (INIS)

    Mao, Teresa; Neelakantan, Prasanna

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome

  17. THREE DIMENSIONAL GRAPHICAL REPRESENTATION OF QUALITY

    Directory of Open Access Journals (Sweden)

    Vineet V. Kumar

    2014-03-01

    Full Text Available Quality is an important aspect for every firm in modern era of competition. Every product has tough competition in terms of market reach. The factor, which actually makes any product long run in market, is quality and hence quality is the stepping-stone for success of any firm. For everyone meaning of quality is different. We have seen several economists who have defined quality by considering different factors, but what all of them have common in them is Customer satisfaction. Customer satisfaction is the ultimate result of quality. In three-dimensional graphical representation of quality, optimum quality is obtained by using three-dimensional graph by considering some important factors governing quality of any product, limiting factor, and customer satisfaction.

  18. Three dimensional contact/impact methodology

    International Nuclear Information System (INIS)

    Kulak, R.F.

    1987-01-01

    The simulation of three-dimensional interface mechanics between reactor components and structures during static contact or dynamic impact is necessary to realistically evaluate their structural integrity to off-normal loads. In our studies of postulated core energy release events, we have found that significant structure-structure interactions occur in some reactor vessel head closure designs and that fluid-structure interactions occur within the reactor vessel. Other examples in which three-dimensional interface mechanics play an important role are: (1) impact response of shipping casks containing spent fuel, (2) whipping pipe impact on reinforced concrete panels or pipe-to-pipe impact after a pipe break, (3) aircraft crash on secondary containment structures, (4) missiles generated by turbine failures or tornados, and (5) drops of heavy components due to lifting accidents. The above is a partial list of reactor safety problems that require adequate treatment of interface mechanics and are discussed in this paper

  19. Three-dimensional simulation of vortex breakdown

    Science.gov (United States)

    Kuruvila, G.; Salas, M. D.

    1990-01-01

    The integral form of the complete, unsteady, compressible, three-dimensional Navier-Stokes equations in the conservation form, cast in generalized coordinate system, are solved, numerically, to simulate the vortex breakdown phenomenon. The inviscid fluxes are discretized using Roe's upwind-biased flux-difference splitting scheme and the viscous fluxes are discretized using central differencing. Time integration is performed using a backward Euler ADI (alternating direction implicit) scheme. A full approximation multigrid is used to accelerate the convergence to steady state.

  20. Impermeability effects in three-dimensional vesicles

    International Nuclear Information System (INIS)

    Biscari, P; Canevese, S M; Napoli, G

    2004-01-01

    We analyse the effects of the impermeability constraint on the equilibrium shapes of a three-dimensional vesicle hosting a rigid inclusion. A given alteration of the inclusion and/or vesicle parameters leads to shape modifications of different orders of magnitude, when applied to permeable or impermeable vesicles. Moreover, the enclosed-volume constraint wrecks the uniqueness of stationary equilibrium shapes, and gives rise to pear-shaped or stomatocyte-like vesicles

  1. Multiparallel Three-Dimensional Optical Microscopy

    Science.gov (United States)

    Nguyen, Lam K.; Price, Jeffrey H.; Kellner, Albert L.; Bravo-Zanoquera, Miguel

    2010-01-01

    Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

  2. Three dimensional analysis of laterally loaded piles

    International Nuclear Information System (INIS)

    Yilmaz, C.

    1987-01-01

    In this study static analysis of laterally loaded pile is studied by the three models. The first model is the beam on discrete elastic springs. This model is analyzed using a flexibility method. The second model is the beam on a two-parameter elastic foundation. This model is analyzed using the linear finite element method. The third model is the finite element model, using the three-dimensional iso-parametric parabolic brick element. Three-dimensional pile group analysis is also performed using elastic constants of single pile obtained by any one of the above analyses. The main objective is to develop computer programs for each model related to single piles and to group analysis. Then, the deflections, rotations, moments, shears, stresses and strains of the single pile are obtained at any arbitrary point. Comparison is made between each model and with other studies such as Poulos 1971, Desai and Appel 1976. In addition, to provide a benchmark of three-dimensional finite element analysis, the Boussinesq problem is analyzed. (orig.)

  3. Three-Dimensional Reconstruction of Sandpile Interiors

    Science.gov (United States)

    Seidler, G. T.

    2001-03-01

    The granular bed, or sandpile, has become one of the condensed matter physicist's favorite systems. In addition to conceptual appeal, the simplest sandpile of monodisperse hard spheres is a valuable model system for understanding powders, liquids, and metallic glasses. Any fundamental approach to the transport and mechanical properties of three-dimensional mesoscale disordered materials must follow from a thorough understanding of their structure. However, in the overwhelming majority of cases, structure measurements have been limited to the mean filling fraction and the structural autocorrelation function. This is particularly unfortunate in the ongoing sandpile renaissance, where some of the most interesting questions concern structure and the relationship between structure and dynamics. I will discuss the combination of synchrotron x-ray microtomography and computer vision algorithms to perform three-dimensional virtual reconstructions of real sandpiles. This technique is rapid and noninvasive, and is applicable to samples large enough to separate bulk and boundary properties. The resulting complete knowledge of structure can be used to calculate otherwise inaccessible correlation functions. I will present results for several measures of the bond-orientational order in three-dimensional sandpiles, including fabric tensors and nematic order parameters.

  4. Three-dimensional deformation of orthodontic brackets

    Science.gov (United States)

    Melenka, Garrett W; Nobes, David S; Major, Paul W

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire–bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design. PMID:23762201

  5. Three-dimensional deformation of orthodontic brackets.

    Science.gov (United States)

    Melenka, Garrett W; Nobes, David S; Major, Paul W; Carey, Jason P

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire-bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design.

  6. Three dimensional illustrating - three-dimensional vision and deception of sensibility

    Directory of Open Access Journals (Sweden)

    Anita Gánóczy

    2009-03-01

    Full Text Available The wide-spread digital photography and computer use gave the opportunity for everyone to make three-dimensional pictures and to make them public. The new opportunities with three-dimensional techniques give chance for the birth of new artistic photographs. We present in detail the biological roots of three-dimensional visualization, the phenomena of movement parallax, which can be used efficiently in making three-dimensional graphics, the Zöllner- and Corridor-illusion. There are present in this paper the visual elements, which contribute to define a plane two-dimensional image in three-dimension: coherent lines, the covering, the measurement changes, the relative altitude state, the abatement of detail profusion, the shadings and the perspective effects of colors.

  7. Three-dimensional analysis of craniofacial bones using three-dimensional computer tomography

    International Nuclear Information System (INIS)

    Ono, Ichiro; Ohura, Takehiko; Kimura, Chu

    1989-01-01

    Three-dimensional computer tomography (3DCT) was performed in patients with various diseases to visualize stereoscopically the deformity of the craniofacial bones. The data obtained were analyzed by the 3DCT analyzing system. A new coordinate system was established using the median sagittal plane of the face (a plane passing through sella, nasion and basion) on the three-dimensional image. Three-dimensional profilograms were prepared for detailed analysis of the deformation of craniofacial bones for cleft lip and palate, mandibular prognathia and hemifacial microsomia. For patients, asymmetry in the frontal view and twist-formed complicated deformities were observed, as well as deformity of profiles in the anteroposterior and up-and-down directions. A newly developed technique allows three-dimensional visualization of changes in craniofacial deformity. It would aid in determining surgical strategy, including crani-facial surgery and maxillo-facial surgery, and in evaluating surgical outcome. (N.K.)

  8. Three-dimensional analysis of craniofacial bones using three-dimensional computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Ichiro; Ohura, Takehiko; Kimura, Chu (Hokkaido Univ., Sapporo (Japan). School of Medicine) (and others)

    1989-08-01

    Three-dimensional computer tomography (3DCT) was performed in patients with various diseases to visualize stereoscopically the deformity of the craniofacial bones. The data obtained were analyzed by the 3DCT analyzing system. A new coordinate system was established using the median sagittal plane of the face (a plane passing through sella, nasion and basion) on the three-dimensional image. Three-dimensional profilograms were prepared for detailed analysis of the deformation of craniofacial bones for cleft lip and palate, mandibular prognathia and hemifacial microsomia. For patients, asymmetry in the frontal view and twist-formed complicated deformities were observed, as well as deformity of profiles in the anteroposterior and up-and-down directions. A newly developed technique allows three-dimensional visualization of changes in craniofacial deformity. It would aid in determining surgical strategy, including crani-facial surgery and maxillo-facial surgery, and in evaluating surgical outcome. (N.K.).

  9. Three-dimensional instability of standing waves

    Science.gov (United States)

    Zhu, Qiang; Liu, Yuming; Yue, Dick K. P.

    2003-12-01

    We investigate the three-dimensional instability of finite-amplitude standing surface waves under the influence of gravity. The analysis employs the transition matrix (TM) approach and uses a new high-order spectral element (HOSE) method for computation of the nonlinear wave dynamics. HOSE is an extension of the original high-order spectral method (HOS) wherein nonlinear wave wave and wave body interactions are retained up to high order in wave steepness. Instead of global basis functions in HOS, however, HOSE employs spectral elements to allow for complex free-surface geometries and surface-piercing bodies. Exponential convergence of HOS with respect to the total number of spectral modes (for a fixed number of elements) and interaction order is retained in HOSE. In this study, we use TM-HOSE to obtain the stability of general three-dimensional perturbations (on a two-dimensional surface) on two classes of standing waves: plane standing waves in a rectangular tank; and radial/azimuthal standing waves in a circular basin. For plane standing waves, we confirm the known result of two-dimensional side-bandlike instability. In addition, we find a novel three-dimensional instability for base flow of any amplitude. The dominant component of the unstable disturbance is an oblique (standing) wave oriented at an arbitrary angle whose frequency is close to the (nonlinear) frequency of the original standing wave. This finding is confirmed by direct long-time simulations using HOSE which show that the nonlinear evolution leads to classical Fermi Pasta Ulam recurrence. For the circular basin, we find that, beyond a threshold wave steepness, a standing wave (of nonlinear frequency Omega) is unstable to three-dimensional perturbations. The unstable perturbation contains two dominant (standing-wave) components, the sum of whose frequencies is close to 2Omega. From the cases we consider, the critical wave steepness is found to generally decrease/increase with increasing radial

  10. Three-dimensional stereo by photometric ratios

    International Nuclear Information System (INIS)

    Wolff, L.B.; Angelopoulou, E.

    1994-01-01

    We present a methodology for corresponding a dense set of points on an object surface from photometric values for three-dimensional stereo computation of depth. The methodology utilizes multiple stereo pairs of images, with each stereo pair being taken of the identical scene but under different illumination. With just two stereo pairs of images taken under two different illumination conditions, a stereo pair of ratio images can be produced, one for the ratio of left-hand images and one for the ratio of right-hand images. We demonstrate how the photometric ratios composing these images can be used for accurate correspondence of object points. Object points having the same photometric ratio with respect to two different illumination conditions constitute a well-defined equivalence class of physical constraints defined by local surface orientation relative to illumination conditions. We formally show that for diffuse reflection the photometric ratio is invariant to varying camera characteristics, surface albedo, and viewpoint and that therefore the same photometric ratio in both images of a stereo pair implies the same equivalence class of physical constraints. The correspondence of photometric ratios along epipolar lines in a stereo pair of images under different illumination conditions is a correspondence of equivalent physical constraints, and the determination of depth from stereo can be performed. Whereas illumination planning is required, our photometric-based stereo methodology does not require knowledge of illumination conditions in the actual computation of three-dimensional depth and is applicable to perspective views. This technique extends the stereo determination of three-dimensional depth to smooth featureless surfaces without the use of precisely calibrated lighting. We demonstrate experimental depth maps from a dense set of points on smooth objects of known ground-truth shape, determined to within 1% depth accuracy

  11. Three-dimensional CT of the mandible

    International Nuclear Information System (INIS)

    Zinreich, S.J.; Price, J.C.; Wang, H.; Ahn, H.S.; Kashima, H.

    1988-01-01

    Seventeen patients with mandibular oblation for facial neoplasia, primary neoplasm, and trauma were evaluated with CT and three-dimensional CT. In eight of these patients, a computerized acrylic model was generated for preoperative planning and postoperative reconstruction. The ramus and body of the mandible were reconstructed with mirror image and fusion techniques. Reconstructions of the anterior mandible were generated from models including the midface, skull based, and residual mandibular fragments. The results are preliminary; however, the authors believe that these represent a powerful new tool and a significant advance in mandibular reconstructive technique, reduced anesthesia time, and the optimized restoration of dental alignment and facial contour

  12. Three-dimensional interpretation of TEM soundings

    Science.gov (United States)

    Barsukov, P. O.; Fainberg, E. B.

    2013-07-01

    We describe the approach to the interpretation of electromagnetic (EM) sounding data which iteratively adjusts the three-dimensional (3D) model of the environment by local one-dimensional (1D) transformations and inversions and reconstructs the geometrical skeleton of the model. The final 3D inversion is carried out with the minimal number of the sought parameters. At each step of the interpretation, the model of the medium is corrected according to the geological information. The practical examples of the suggested method are presented.

  13. Three Dimensional Double Layers in Magnetized Plasmas

    DEFF Research Database (Denmark)

    Jovanovic, D.; Lynov, Jens-Peter; Michelsen, Poul

    1982-01-01

    Experimental results are presented which demonstrate the formation of fully three dimensional double layers in a magnetized plasma. The measurements are performed in a magnetized stationary plasma column with radius 1.5 cm. Double layers are produced by introducing an electron beam with radius 0.......4 cm along the magnetic field from one end of the column. The voltage drop across the double layer is found to be determined by the energy of the incoming electron beam. In general we find that the width of the double layer along the external magnetic field is determined by plasma density and beam...

  14. Three-dimensional flow about penguin wings

    Science.gov (United States)

    Noca, Flavio; Sudki, Bassem; Lauria, Michel

    2012-11-01

    Penguins, contrary to airborne birds, do not need to compensate for gravity. Yet, the kinematics of their wings is highly three-dimensional and seems exceedingly complex for plain swimming. Is such kinematics the result of an evolutionary optimization or is it just a forced adaptation of an airborne flying apparatus to underwater swimming? Some answers will be provided based on flow dynamics around robotic penguin wings. Updates will also be presented on the development of a novel robotic arm intended to simulate penguin swimming and enable novel propulsion devices.

  15. Three-dimensional teletherapy treatment planning

    International Nuclear Information System (INIS)

    Panthaleon van Eck, R.B. van.

    1986-01-01

    This thesis deals with physical/mathematical backgrounds of computerized teletherapy treatment planning. The subjects discussed in this thesis can be subdivided into three main categories: a) Three-dimensional treatment planning. A method is evaluated which can be used for the purpose of simulation and optimization of dose distributions in three dimensions. b) The use of Computed Tomography. The use of patient information obtained from Computed Tomography for the purpose of dose computations is evaluated. c) Dose computational models for photon- and electron beams. Models are evaluated which provide information regarding the way in which the radiation dose is distributed in the patient (viz. is absorbed and/or dispersed). (Auth.)

  16. Creating three-dimensional thermal maps

    CSIR Research Space (South Africa)

    Price

    2011-11-01

    Full Text Available stream_source_info Price_2011.pdf.txt stream_content_type text/plain stream_size 30895 Content-Encoding ISO-8859-1 stream_name Price_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Creating Three...-Dimensional Thermal Maps Mathew Price Cogency cc Cape Town Email: mathew@cogency.co.za Jeremy Green CSIR Centre for Mining Innovation Johannesburg Email: jgreen@csir.co.za John Dickens CSIR Centre for Mining Innovation Johannesburg Email: jdickens...

  17. Three-dimensional cooling of muons

    CERN Document Server

    Vsevolozhskaya, T A

    2000-01-01

    The simultaneous ionization cooling of muon beams in all three - the longitudinal and two transverse - directions is considered in a scheme, based on bent lithium lenses with dipole constituent of magnetic field in them, created by a special configuration of current-carrying rod. An analysis of three-dimensional cooling is performed with the use of kinetic equation method. Results of numerical calculation for a specific beam line configuration are presented together with results of computer simulation using the Moliere distribution to describe the Coulomb scattering and the Vavilov distribution used to describe the ionization loss of energy.

  18. Three-dimensional radiation treatment planning

    International Nuclear Information System (INIS)

    Mohan, R.

    1989-01-01

    A major aim of radiation therapy is to deliver sufficient dose to the tumour volume to kill the cancer cells while sparing the nearby health organs to prevent complications. With the introduction of devices such as CT and MR scanners, radiation therapy treatment planners have access to full three-dimensional anatomical information to define, simulate, and evaluate treatments. There are a limited number of prototype software systems that allow 3D treatment planning currently in use. In addition, there are more advanced tools under development or still in the planning stages. They require sophisticated graphics and computation equipment, complex physical and mathematical algorithms, and new radiation treatment machines that deliver dose very precisely under computer control. Components of these systems include programs for the identification and delineation of the anatomy and tumour, the definition of radiation beams, the calculation of dose distribution patterns, the display of dose on 2D images and as three dimensional surfaces, and the generation of computer images to verify proper patient positioning in treatment. Some of these functions can be performed more quickly and accurately if artificial intelligence or expert systems techniques are employed. 28 refs., figs

  19. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  20. Three-dimensional image signals: processing methods

    Science.gov (United States)

    Schiopu, Paul; Manea, Adrian; Craciun, Anca-Ileana; Craciun, Alexandru

    2010-11-01

    Over the years extensive studies have been carried out to apply coherent optics methods in real-time processing, communications and transmission image. This is especially true when a large amount of information needs to be processed, e.g., in high-resolution imaging. The recent progress in data-processing networks and communication systems has considerably increased the capacity of information exchange. We describe the results of literature investigation research of processing methods for the signals of the three-dimensional images. All commercially available 3D technologies today are based on stereoscopic viewing. 3D technology was once the exclusive domain of skilled computer-graphics developers with high-end machines and software. The images capture from the advanced 3D digital camera can be displayed onto screen of the 3D digital viewer with/ without special glasses. For this is needed considerable processing power and memory to create and render the complex mix of colors, textures, and virtual lighting and perspective necessary to make figures appear three-dimensional. Also, using a standard digital camera and a technique called phase-shift interferometry we can capture "digital holograms." These are holograms that can be stored on computer and transmitted over conventional networks. We present some research methods to process "digital holograms" for the Internet transmission and results.

  1. Three dimensional animated images of anorectal malformations

    International Nuclear Information System (INIS)

    Ueno, Shigeru; Yanagimachi, Noriharu; Muro, Isao; Komiya, Taizo; Yokoyama, Seishichi; Hirakawa, Hitoshi; Tajima, Tomoo; Mitomi, Toshio; Suto, Yasuzo.

    1996-01-01

    Accurate reconstruction of the pelvic structures is a most important factor in obtaining a desirable result after anorectoplasty for a patient with anorectal malformation. Preoperative evaluation of the anatomy is indispensable for choosing an appropriate operative method in each case. To facilitate preoperative evaluation, three dimensional animated images of the pelvic structure of patients with anorectal malformations were constructed by computer graphics based upon tomographic images obtained from magnetic resonance imaging. Axial 1-mm thick images of the pelvic portion were generated with spoiling pulse gradient echo sequences using short repetition times (13 msec TR) and short echo times (6 msec TE) with a flip angle of 25 degrees with the patient in the jack-knife position. Graphic data from MR images were transferred to a graphic work station and processed on it. The skin surface, the ano-rectum, the lower urinary tract and the sphincter musculature were segmented by thresholding images by the signal intensity. Three dimensional images were displayed by surface rendering method using the segmented data of each organ and then animation images of these organs were obtained. The anatomy of each type of anomaly was easily recognized by 3-D visualization, and animation of the pelvic viscera and the sphincter musculature made the images more realistic. Animated images of the musculature were especially useful for simulating surgical procedures and could be helpful for reviewing surgical results. (author)

  2. Three-dimensional analysis of antenna sheaths

    International Nuclear Information System (INIS)

    Myra, J.R.; D'Ippolito, D.A.; Ho, Y.L.

    1996-01-01

    The present work is motivated by the importance of r.f. sheaths in determining the antenna-plasma interaction and the sensitivity of the sheaths to the complicated three-dimensional structure of modern ion cyclotron range of frequency (ICRF) antennas. To analyze r.f. sheaths on the plasma facing regions of the launcher, we first calculate the contact points of the tokamak magnetic field lines on the surface of the antenna Faraday screen and nearby limiters for realistic three-dimensional magnetic flux surface and antenna geometries. Next, the r.f. voltage that can drive sheaths at the contact points is determined and used to assess the resulting sheath power dissipation, r.f.-driven sputtering, and r.f.-induced convective cells (which produce edge profile modification). The calculations are embodied in a computer code, ANSAT (antenna sheath analysis tool), and sample ANSAT runs are shown to highlight the physics- and geometry-dependent characteristics of the r.f. sheaths and their relationship to the antenna design. One use of ANSAT is therefore as a design tool, to assess the strengths and weaknesses of a given design with respect to critical voltage handling and edge plasma interaction issues. Additionally, examples are presented where ANSAT has been useful in the analysis and interpretation of ICRF experiments (orig.)

  3. Acurácia diagnóstica da histerossalpingografia e da ultra-sonografia para avaliação de doenças da cavidade uterina em pacientes com abortamento recorrente Diagnostic accuracy of hysterosalpingography and transvaginal sonography to evaluate uterine cavity diseases in patients with recurrent miscarriage

    Directory of Open Access Journals (Sweden)

    Évelyn Traina

    2004-01-01

    Full Text Available OBJETIVO: avaliar a acurácia da histerossalpingografia e da ultra-sonografia transvaginal bidimensional para o diagnóstico de defeitos uterinos em pacientes com aborto recorrente. MÉTODOS: oitenta pacientes com história de dois ou mais abortos espontâneos consecutivos foram submetidas a histerossalpingografia, ultra-sonografia bidimensional pélvica e transvaginal e histeroscopia ambulatorial. Os achados foram divididos em três grupos: alterações da forma, sinéquias e lesões polipóides. A histeroscopia foi considerada padrão-ouro. A concordância entre os diferentes métodos foi avaliada pelo coeficiente kappa e sua significância foi testada. O nível de significância adotado foi de 0,05 (alfa=5%. Sensibilidade, especificidade, valores preditivos positivo e negativo, com intervalos de confiança de 95%, foram calculados. RESULTADOS: defeitos cavitários foram diagnosticados em 29 (36,3% pacientes, sendo 11 (13,7% alterações da forma, 17 (21,3% sinéquias e uma (1,3% lesão polipóide. A concordância global da histerossalpingografia com a histeroscopia foi de 85,0%, ao passo que da ultra-sonografia foi de apenas 78,7%. Os melhores resultados da histerossalpingografia foram obtidos para os diagnósticos de alterações da forma e sinéquias (acurácia de, respectivamente, 97,5 e 95%. Para lesões polipóides, a histerossalpingografia teve acurácia de apenas 92,5%, devido ao baixo valor preditivo positivo (14,3%. A ultra-sonografia teve acurácia inferior para todos os diagnósticos, 93,7% para alterações da forma e 85% para detecção de sinéquias, às custas principalmente de baixa sensibilidade. CONCLUSÕES: a histerossalpingografia revelou boa acurácia diagnóstica para a pesquisa da cavidade uterina em pacientes com aborto recorrente. A ultra-sonografia mostrou especificidade alta, porém com baixa sensibilidade.PURPOSE: to evaluate the diagnostic accuracy of hysterosalpingography (HSG and transvaginal sonography (TVS in

  4. Steady, three-dimensional, internally heated convection

    International Nuclear Information System (INIS)

    Schubert, G.; Glatzmaier, G.A.; Travis, B.

    1993-01-01

    Numerical calculations have been carried out of steady, symmetric, three-dimensional modes of convection in internally heated, infinite Prandtl number, Boussinesq fluids at a Rayleigh number of 1.4x10 4 in a spherical shell with inner/outer radius of 0.55 and in a 3x3x1 rectangular box. Multiple patterns of convection occur in both geometries. In the Cartesian geometry the patterns are dominated by cylindrical cold downflows and a broad hot upwelling. In the spherical geometry the patterns consist of cylindrical cold downwellings centered either at the vertices of a tetrahedron or the centers of the faces of a cube. The cold downflow cylinders are immersed in a background of upwelling within which there are cylindrical hot concentrations (plumes) and hot halos around the downflows. The forced hot upflow return plumes of internally heated spherical convection are fundamentally different from the buoyancy-driven plumes of heated from below convection

  5. Exact solutions in three-dimensional gravity

    CERN Document Server

    Garcia-Diaz, Alberto A

    2017-01-01

    A self-contained text, systematically presenting the determination and classification of exact solutions in three-dimensional Einstein gravity. This book explores the theoretical framework and general physical and geometrical characteristics of each class of solutions, and includes information on the researchers responsible for their discovery. Beginning with the physical character of the solutions, these are identified and ordered on the basis of their geometrical invariant properties, symmetries, and algebraic classifications, or from the standpoint of their physical nature, for example electrodynamic fields, fluid, scalar field, or dilaton. Consequently, this text serves as a thorough catalogue on 2+1 exact solutions to the Einstein equations coupled to matter and fields, and on vacuum solutions of topologically massive gravity with a cosmological constant. The solutions are also examined from different perspectives, enabling a conceptual bridge between exact solutions of three- and four-dimensional gravit...

  6. Three-dimensional printing physiology laboratory technology.

    Science.gov (United States)

    Sulkin, Matthew S; Widder, Emily; Shao, Connie; Holzem, Katherine M; Gloschat, Christopher; Gutbrod, Sarah R; Efimov, Igor R

    2013-12-01

    Since its inception in 19th-century Germany, the physiology laboratory has been a complex and expensive research enterprise involving experts in various fields of science and engineering. Physiology research has been critically dependent on cutting-edge technological support of mechanical, electrical, optical, and more recently computer engineers. Evolution of modern experimental equipment is constrained by lack of direct communication between the physiological community and industry producing this equipment. Fortunately, recent advances in open source technologies, including three-dimensional printing, open source hardware and software, present an exciting opportunity to bring the design and development of research instrumentation to the end user, i.e., life scientists. Here we provide an overview on how to develop customized, cost-effective experimental equipment for physiology laboratories.

  7. Towards microscale electrohydrodynamic three-dimensional printing

    International Nuclear Information System (INIS)

    He, Jiankang; Xu, Fangyuan; Cao, Yi; Liu, Yaxiong; Li, Dichen

    2016-01-01

    It is challenging for the existing three-dimensional (3D) printing techniques to fabricate high-resolution 3D microstructures with low costs and high efficiency. In this work we present a solvent-based electrohydrodynamic 3D printing technique that allows fabrication of microscale structures like single walls, crossed walls, lattice and concentric circles. Process parameters were optimized to deposit tiny 3D patterns with a wall width smaller than 10 μm and a high aspect ratio of about 60. Tight bonding among neighbour layers could be achieved with a smooth lateral surface. In comparison with the existing microscale 3D printing techniques, the presented method is low-cost, highly efficient and applicable to multiple polymers. It is envisioned that this simple microscale 3D printing strategy might provide an alternative and innovative way for application in MEMS, biosensor and flexible electronics. (paper)

  8. Three-dimensional hologram display system

    Science.gov (United States)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  9. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  10. Towards microscale electrohydrodynamic three-dimensional printing

    Science.gov (United States)

    He, Jiankang; Xu, Fangyuan; Cao, Yi; Liu, Yaxiong; Li, Dichen

    2016-02-01

    It is challenging for the existing three-dimensional (3D) printing techniques to fabricate high-resolution 3D microstructures with low costs and high efficiency. In this work we present a solvent-based electrohydrodynamic 3D printing technique that allows fabrication of microscale structures like single walls, crossed walls, lattice and concentric circles. Process parameters were optimized to deposit tiny 3D patterns with a wall width smaller than 10 μm and a high aspect ratio of about 60. Tight bonding among neighbour layers could be achieved with a smooth lateral surface. In comparison with the existing microscale 3D printing techniques, the presented method is low-cost, highly efficient and applicable to multiple polymers. It is envisioned that this simple microscale 3D printing strategy might provide an alternative and innovative way for application in MEMS, biosensor and flexible electronics.

  11. An Introduction of Three-dimensional Grammar

    Directory of Open Access Journals (Sweden)

    Fan Xiao

    2017-12-01

    Full Text Available This paper introduces some key points of Three-dimensional Grammar. As for the structure, it can be distinguished into syntactic structure, semantic structure and pragmatic structure from the perspectives of syntax, semantics and pragmatics. And the same is true with the followings, such as grammatical constituents, grammatical functions, grammatical meanings, grammatical focuses. Sentence types which is called sentence pattern, sentence model and sentence types respectively, and analysis methods. This paper proposes that grammatical researches should be done in accordance with the four principles, that is form and meaning co-verified, static and dynamic co-referenced, structure and function co-testified and description and interpretation co-promoted.

  12. Three-dimensional function photonic crystals

    Science.gov (United States)

    Zhang, Hai-Feng

    2017-11-01

    In this paper, the properties of the photonic band gaps (PBGs) of three-dimensional (3D) function photonic crystals (PCs) are theoretically investigated by a modified plane wave expansion (PWE) method, whose equations for computations are deduced. The configuration of 3D function PCs is the dielectric spheres inserted in the air background with simple-cubic (SC) lattices whose dielectric constants are the functions of space coordinates, which can be realized by the electro-optical or optical Kerr effect in the practice. The influences of the parameter for 3D function PCs on the PBGs also are discussed. The calculated results show that the bandwidths and number of PBGs can be tuned with different distributions of function dielectrics. Compared with the conventional 3D dielectric PCs with SC lattices, the larger and more PBGs can be obtained in the 3D function PCs. Those results provide a new way to design the novel practical devices.

  13. Three-dimensional tori and Arnold tongues

    Energy Technology Data Exchange (ETDEWEB)

    Sekikawa, Munehisa, E-mail: sekikawa@cc.utsunomiya-u.ac.jp [Department of Mechanical and Intelligent Engineering, Utsunomiya University, Utsunomiya-shi 321-8585 (Japan); Inaba, Naohiko [Organization for the Strategic Coordination of Research and Intellectual Property, Meiji University, Kawasaki-shi 214-8571 (Japan); Kamiyama, Kyohei [Department of Electronics and Bioinformatics, Meiji University, Kawasaki-shi 214-8571 (Japan); Aihara, Kazuyuki [Institute of Industrial Science, the University of Tokyo, Meguro-ku 153-8505 (Japan)

    2014-03-15

    This study analyzes an Arnold resonance web, which includes complicated quasi-periodic bifurcations, by conducting a Lyapunov analysis for a coupled delayed logistic map. The map can exhibit a two-dimensional invariant torus (IT), which corresponds to a three-dimensional torus in vector fields. Numerous one-dimensional invariant closed curves (ICCs), which correspond to two-dimensional tori in vector fields, exist in a very complicated but reasonable manner inside an IT-generating region. Periodic solutions emerge at the intersections of two different thin ICC-generating regions, which we call ICC-Arnold tongues, because all three independent-frequency components of the IT become rational at the intersections. Additionally, we observe a significant bifurcation structure where conventional Arnold tongues transit to ICC-Arnold tongues through a Neimark-Sacker bifurcation in the neighborhood of a quasi-periodic Hopf bifurcation (or a quasi-periodic Neimark-Sacker bifurcation) boundary.

  14. Multiscale modeling of three-dimensional genome

    Science.gov (United States)

    Zhang, Bin; Wolynes, Peter

    The genome, the blueprint of life, contains nearly all the information needed to build and maintain an entire organism. A comprehensive understanding of the genome is of paramount interest to human health and will advance progress in many areas, including life sciences, medicine, and biotechnology. The overarching goal of my research is to understand the structure-dynamics-function relationships of the human genome. In this talk, I will be presenting our efforts in moving towards that goal, with a particular emphasis on studying the three-dimensional organization, the structure of the genome with multi-scale approaches. Specifically, I will discuss the reconstruction of genome structures at both interphase and metaphase by making use of data from chromosome conformation capture experiments. Computationally modeling of chromatin fiber at atomistic level from first principles will also be presented as our effort for studying the genome structure from bottom up.

  15. Three-dimensional reconstruction of CT images

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Toshiaki; Kattoh, Keiichi; Kawakami, Genichiroh; Igami, Isao; Mariya, Yasushi; Nakamura, Yasuhiko; Saitoh, Yohko; Tamura, Koreroku; Shinozaki, Tatsuyo

    1986-09-01

    Computed tomography (CT) has the ability to provide sensitive visualization of organs and lesions. Owing to the nature of CT to be transaxial images, a structure which is greater than a certain size appears as several serial CT images. Consequently each observer must reconstruct those images into a three-dimensional (3-D) form mentally. It has been supposed to be of great use if such a 3-D form can be described as a definite figure. A new computer program has been developed which can produce 3-D figures from the profiles of organs and lesions on CT images using spline curves. The figures obtained through this method are regarded to have practical applications.

  16. Full three-dimensional isotropic transformation media

    International Nuclear Information System (INIS)

    García-Meca, C; Martí, J; Martínez, A; Ortuño, R

    2014-01-01

    We present a method that enables the implementation of full three-dimensional (3D) transformation media with minimized anisotropy. It is based on a special kind of shape-preserving mapping and a subsequent optimization process. For sufficiently smooth transformations, the resulting anisotropy can be neglected, paving the way for practically realizable 3D devices. The method is independent of the considered wave phenomenon and can thus be applied to any field for which a transformational technique exists, such as acoustics or thermodynamics. Full 3D isotropy has an additional important implication for optical transformation media, as it eliminates the need for magnetic materials in many situations. To illustrate the potential of the method, we design 3D counterparts of transformation-based electromagnetic squeezers and bends. (paper)

  17. The Three-Dimensional EIT Wave

    Science.gov (United States)

    Thompson, B. J.; Biesecker, D. A.; Gilbert, H. R.; Lawrence, G. R.; Ofman, L.; Wu, S. T.; Warmuth, A.; Fisher, Richard R. (Technical Monitor)

    2002-01-01

    An EIT wave is an impulsive disturbance which has been observed in the EUV, Soft X-ray and white light corona, with corresponding observations in the chromosphere. The effects of these disturbances can be observed across the entire solar disk of the Sun, and throughout the inner heliosphere as well. However, the picture is not complete; observations alone do not establish a complete understanding of the nature of this three-dimensional phenomenon. A number of associated phenomena have been documented, though in most cases causality has not determined. Additionally, it is unclear which factors govern the impulse's ability to affect regions of the corona and heliosphere. We discuss the various observations and the models which provided links between the associated phenomena.

  18. Three-dimensional (3D) analysis of the temporomandibular joint

    DEFF Research Database (Denmark)

    Kitai, N.; Kreiborg, S.; Murakami, S.

    Symposium Orthodontics 2001: Where are We Now? Where are We Going?, three-dimensional analysis, temporomandibular joint......Symposium Orthodontics 2001: Where are We Now? Where are We Going?, three-dimensional analysis, temporomandibular joint...

  19. Study on three dimensional seismic isolation system

    International Nuclear Information System (INIS)

    Morishita, Masaki; Kitamura, Seiji

    2003-01-01

    Japan Nuclear Cycle Development Institute (JNC) and Japan Atomic Power Company (JAPC) launched joint research programs on structural design and three-dimensional seismic isolation technologies, as part of the supporting R and D activities for the feasibility studies on commercialized fast breeder reactor cycle systems. A research project by JAPC under the auspices of the Ministry of Economy, Trade, and Industry (METI) with technical support by JNC is included in this joint study. This report contains the results of the research on the three-dimensional seismic isolation technologies, and the results of this year's study are summarized in the following five aspects. (1) Study on Earthquake Condition for Developing 3-dimensional Base Isolation System. The case study S2 is one of the maximum ground motions, of which the records were investigated up to this time. But a few observed near the fault exceed the case study S2 in the long period domain, depending on the fault length and conditions. Generally it is appropriate that the response spectra ratio (vertical/horizontal) is 0.6. (2) Performance Requirement for 3-dimensional Base Isolation System and Devices. Although the integrity map of main equipment/piping dominate the design criteria for the 3-dimensional base isolation system, the combined integrity map is the same as those of FY 2000, which are under fv=1Hz and over hv=20%. (3) Developing Targets and Schedule for 3-dimensional Isolation Technology. The target items for 3-dimensional base isolation system were rearranged into a table, and developing items to be examined concerning the device were also adjusted. A development plan until FY 2009 was made from the viewpoint of realization and establishment of a design guideline on 3-dimensional base isolation system. (4) Study on 3-dimensional Entire Building Base Isolation System. Three ideas among six ideas that had been proposed in FY2001, i.e., '3-dimensional base isolation system incorporating hydraulic

  20. Clinical significance of three-dimensional sonohysterography

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Lee, Mi Hwa; Lee, Chan; Kim, Jong Wook; Shin, Myung Choel

    1999-01-01

    To evaluate the usefulness of three dimensional sonohysterography (3D SHG) in the evaluation of uterine endometrial and submucosal lesions in comparison with conventional two-dimensional sonohysterography (2D SHG). Our series consisted of 26 patients (mean aged 41 years) who complained of uterine bleeding, menorrhagia, or dysmenorrhea. 2D SHG was performed, and then 3D SHG was done after the volume mode was switched on. Simultaneous display of three perpendicular two-dimensional planes and surface rendering of findings on particular section were obtained. We analyzed whether the endometrium was thickened or not, and the location, size, shape, echogenicity, posterior shadowing, and echogenic rim of the focal lesion. The results were compared with the pathologic findings or MRI. There were submucosal myomas (n=12), intramural myomas (n=2), endometrial polyps (n=7), placental polyp (n=1), and normal endometrial cavities (n=4) on SHG. Nineteen cases were confirmed by pathologic findings or MRI. The results were correlated in 89% (17/19) of the cases. We misdiagnosed 2 cases: focal endometrial hyperplasia and choriocarcinoma were misdiagnosed as endometrial polyp and placental polyp, respectively. Imaging diagnoses were same in the techniques. Comparing with 2D SHG, 3D SHG provided a subjective display of pathologic findings and an additional information about spatial relationship between focal lesion and surroundings.

  1. Clinical significance of three-dimensional sonohysterography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hye; Lee, Mi Hwa; Lee, Chan; Kim, Jong Wook; Shin, Myung Choel [Pochon Cha University College of Medicine, Pochon (Korea, Republic of)

    1999-12-15

    To evaluate the usefulness of three dimensional sonohysterography (3D SHG) in the evaluation of uterine endometrial and submucosal lesions in comparison with conventional two-dimensional sonohysterography (2D SHG). Our series consisted of 26 patients (mean aged 41 years) who complained of uterine bleeding, menorrhagia, or dysmenorrhea. 2D SHG was performed, and then 3D SHG was done after the volume mode was switched on. Simultaneous display of three perpendicular two-dimensional planes and surface rendering of findings on particular section were obtained. We analyzed whether the endometrium was thickened or not, and the location, size, shape, echogenicity, posterior shadowing, and echogenic rim of the focal lesion. The results were compared with the pathologic findings or MRI. There were submucosal myomas (n=12), intramural myomas (n=2), endometrial polyps (n=7), placental polyp (n=1), and normal endometrial cavities (n=4) on SHG. Nineteen cases were confirmed by pathologic findings or MRI. The results were correlated in 89% (17/19) of the cases. We misdiagnosed 2 cases: focal endometrial hyperplasia and choriocarcinoma were misdiagnosed as endometrial polyp and placental polyp, respectively. Imaging diagnoses were same in the techniques. Comparing with 2D SHG, 3D SHG provided a subjective display of pathologic findings and an additional information about spatial relationship between focal lesion and surroundings.

  2. Bifurcation analysis of a three dimensional system

    Directory of Open Access Journals (Sweden)

    Yongwen WANG

    2018-04-01

    Full Text Available In order to enrich the stability and bifurcation theory of the three dimensional chaotic systems, taking a quadratic truncate unfolding system with the triple singularity equilibrium as the research subject, the existence of the equilibrium, the stability and the bifurcation of the system near the equilibrium under different parametric conditions are studied. Using the method of mathematical analysis, the existence of the real roots of the corresponding characteristic equation under the different parametric conditions is analyzed, and the local manifolds of the equilibrium are gotten, then the possible bifurcations are guessed. The parametric conditions under which the equilibrium is saddle-focus are analyzed carefully by the Cardan formula. Moreover, the conditions of codimension-one Hopf bifucation and the prerequisites of the supercritical and subcritical Hopf bifurcation are found by computation. The results show that the system has abundant stability and bifurcation, and can also supply theorical support for the proof of the existence of the homoclinic or heteroclinic loop connecting saddle-focus and the Silnikov's chaos. This method can be extended to study the other higher nonlinear systems.

  3. Three-dimensional dynamics of protostellar evolution

    International Nuclear Information System (INIS)

    Cook, T.L.

    1977-06-01

    A three-dimensional finite difference numerical methodology was developed for self-gravitating, rotating gaseous systems. The fully nonlinear equations for time-varying fluid dynamics are solved by high speed computer in a cylindrical coordinate system rotating with an instantaneous angular velocity, selected such that the net angular momentum relative to the rotating frame is zero. The time-dependent adiabatic collapse of gravitationally bound, rotating, protostellar clouds is studied for specified uniform and nonuniform initial conditions. Uniform clouds can form axisymmetric, rotating toroidal configurations. If the thermal pressure is high, nonuniform clouds can also collapse to axisymmetric toroids. For low thermal pressures, however, the collapsing cloud is unstable to initial perturbations. The fragmentation of protostellar clouds is investigated by studying the response of rotating, self-gravitating, equilibrium toroids to non-axisymmetric perturbations. The detailed evolution of the fragmenting toroid depends upon a non-dimensional function of the initial entropy, the total mass in the toroid, the angular velocity of rotation, and the number of perturbation wavelengths around the circumference of the toroid. For low and intermediate entropies, the configuration develops into co-rotating components with spiral streamers. In the spiral regions retrograde vortices are observed in some examples. For high levels of entropy, barred spirals can exist as intermediate states of the fragmentation

  4. Three-dimensional dynamics of protostellar evolution

    International Nuclear Information System (INIS)

    Cook, T.L.; Harlow, F.H.

    1978-01-01

    A three-dimensional finite difference numerical methodology has been developed for self-gravitating, rotating gaseous systems. The fully nonlinear equations for time-varying fluid dynamics are solved by high-speed computer in a cylindrical coordinate system rotating with an instantaneous angular velocity. The time-dependent adiabatic collapse of gravitationally bound, rotating, protostellar clouds is studied for specified uniform and nonuniform initial conditions. Uniform clouds can form axisymmetric, rotating toroidal configurations. If the thermal pressure is high, nonuniform clouds can also collapse to axisymmetric ellipsoids. For low thermal pressures, however, the collapsing cloud is unstable to perturbations. The resulting fragmentation of unstable protostellar clouds is investigated by studying the response of rotating, self-gravitating, equilibrium toroids to nonaxisymmetric perturbations. The detailed evolution of the fragmentation toroid depends upon a nondimensional function of the initial entropy, the total mass in the toroid, the angular velocity of rotation, and the number of perturbation wave-lengths around the circumference of the toroid. For low and intermediate entropies, the configuration develops into corotating components with spiral streamers. In the spiral regions retrograde vortices are observed in some examples. For high levels of entropy, barred spirals can exist as intermediate states of the fragmentation

  5. Three dimensional characterization and archiving system

    International Nuclear Information System (INIS)

    Sebastian, R.L.; Clark, R.; Gallman, P.

    1995-01-01

    The Three Dimensional Characterization and Archiving System (3D-ICAS) is being developed as a remote system to perform rapid in situ analysis of hazardous organics and radionuclide contamination on structural materials. Coleman Research and its subcontractors, Thermedics Detection, Inc. (TD) and the University of Idaho (UI) are in the second phase of a three phase program to develop 3D-ICAS to support Decontamination and Decommissioning (D ampersand D) operations. Accurate physical characterization of surfaces and the radioactive and organic is a critical D ampersand D task. Surface characterization includes identification of potentially dangerous inorganic materials, such as asbestos and transite. Real-time remotely operable characterization instrumentation will significantly advance the analysis capabilities beyond those currently employed. Chemical analysis is a primary area where the characterization process will be improved. Chemical analysis plays a vital role throughout the process of decontamination. Before clean-up operations can begin the site must be characterized with respect to the type and concentration of contaminants, and detailed site mapping must clarify areas of both high and low risk. During remediation activities chemical analysis provides a means to measure progress and to adjust clean-up strategy. Once the clean-up process has been completed the results of chemical analysis will verify that the site is in compliance with federal and local regulations

  6. MORPHOLOGICAL DESCRIPTIONS USING THREE-DIMENSIONAL WAVEFRONTS

    Directory of Open Access Journals (Sweden)

    Jean Serra

    2011-05-01

    Full Text Available The present study deals with the analysis of three-dimensional binary objects whose structure is not obvious nor generally clearly visible. Our approach is illustrated through three examples taken from biological microscopy. In one of our examples, we need to extract the osteocytes contained in sixty confocal sections. The cells are not numerous, but are characterized by long branches, hence they will be separated using a directional wavefront The two other objects are more complex and will be analysed by means of a spherical wavefront In the first case, a kidney of a rat embryo, the tissue grows like a tree, where we want to detect the branches, their extremities,and their spatial arrangement. The wavefront method enables us to define precisely branches and extremities, and gives flexible algorithms. The last example deals with the embryonic growth of the chicken shinbone. The central part of the bone (or shaft is structured as a series of nested cylinders following the same axis, and connected by more or less long bridges. Using wavefronts, we show that it is possible to separate the cylinders,and to extract and count the bridges that connect them.

  7. Multimodal three-dimensional dynamic signature

    Directory of Open Access Journals (Sweden)

    Yury E. Kozlov

    2017-11-01

    Full Text Available Reliable authentication in mobile applications is among the most important information security challenges. Today, we can hardly imagine a person who would not own a mobile device that connects to the Internet. Mobile devices are being used to store large amounts of confidential information, ranging from personal photos to electronic banking tools. In 2009, colleagues from Rice University together with their collaborators from Motorola, proposed an authentication through in-air gestures. This and subsequent work contributing to the development of the method are reviewed in our introduction. At the moment, there exists a version of the gesture-based authentication software available for Android mobile devices. This software has not become widespread yet. One of likely reasons for that is the insufficient reliability of the method, which involves similar to its earlier analogs the use of only one device. Here we discuss the authentication based on the multimodal three-dimensional dynamic signature (MTDS performed by two independent mobile devices. The MTDS-based authentication technique is an advanced version of in-air gesture authentication. We describe the operation of a prototype of MTDS-based authentication, including the main implemented algorithms, as well as some preliminary results of testing the software. We expect that our method can be used in any mobile application, provided a number of additional improvements discussed in the conclusion are made.

  8. Three dimensional image alignment, registration and fusion

    International Nuclear Information System (INIS)

    Treves, S.T.; Mitchell, K.D.; Habboush, I.H.

    1998-01-01

    Combined assessment of three dimensional anatomical and functional images (SPECT, PET, MRI, CT) is useful to determine the nature and extent of lesions in many parts of the body. Physicians principally rely on their spatial sense of mentally re-orient and overlap images obtained with different imaging modalities. Objective methods that enable easy and intuitive image registration can help the physician arrive at more optimal diagnoses and better treatment decisions. This review describes a simple, intuitive and robust image registration approach developed in our laboratory. It differs from most other registration techniques in that it allows the user to incorporate all of the available information within the images in the registration process. This method takes full advantage of the ability of knowledgeable operators to achieve image registration and fusion using an intuitive interactive visual approach. It can register images accurately and quickly without the use of elaborate mathematical modeling or optimization techniques. The method provides the operator with tools to manipulate images in three dimensions, including visual feedback techniques to assess the accuracy of registration (grids, overlays, masks, and fusion of images in different colors). Its application is not limited to brain imaging and can be applied to images from any region in the body. The overall effect is a registration algorithm that is easy to implement and can achieve accuracy on the order of one pixel

  9. Three-Dimensional Printed Thermal Regulation Textiles.

    Science.gov (United States)

    Gao, Tingting; Yang, Zhi; Chen, Chaoji; Li, Yiju; Fu, Kun; Dai, Jiaqi; Hitz, Emily M; Xie, Hua; Liu, Boyang; Song, Jianwei; Yang, Bao; Hu, Liangbing

    2017-11-28

    Space cooling is a predominant part of energy consumption in people's daily life. Although cooling the whole building is an effective way to provide personal comfort in hot weather, it is energy-consuming and high-cost. Personal cooling technology, being able to provide personal thermal comfort by directing local heat to the thermally regulated environment, has been regarded as one of the most promising technologies for cooling energy and cost savings. Here, we demonstrate a personal thermal regulated textile using thermally conductive and highly aligned boron nitride (BN)/poly(vinyl alcohol) (PVA) composite (denoted as a-BN/PVA) fibers to improve the thermal transport properties of textiles for personal cooling. The a-BN/PVA composite fibers are fabricated through a fast and scalable three-dimensional (3D) printing method. Uniform dispersion and high alignment of BN nanosheets (BNNSs) can be achieved during the processing of fiber fabrication, leading to a combination of high mechanical strength (355 MPa) and favorable heat dispersion. Due to the improved thermal transport property imparted by the thermally conductive and highly aligned BNNSs, better cooling effect (55% improvement over the commercial cotton fiber) can be realized in the a-BN/PVA textile. The wearable a-BN/PVA textiles containing the 3D-printed a-BN/PVA fibers offer a promising selection for meeting the personal cooling requirement, which can significantly reduce the energy consumption and cost for cooling the whole building.

  10. Three-dimensional printing for craniomaxillofacial regeneration.

    Science.gov (United States)

    Gaviria, Laura; Pearson, Joseph J; Montelongo, Sergio A; Guda, Teja; Ong, Joo L

    2017-10-01

    Craniomaxillofacial injuries produce complex wound environments involving various tissue types and treatment strategies. In a clinical setting, care is taken to properly irrigate and stabilize the injury, while grafts are molded in an attempt to maintain physiological functionality and cosmesis. This often requires multiple surgeries and grafts leading to added discomfort, pain and financial burden. Many of these injuries can lead to disfigurement and resultant loss of system function including mastication, respiration, and articulation, and these can lead to acute and long-term psychological impact on the patient. A main causality of these issues is the lack of an ability to spatially control pre-injury morphology while maintaining shape and function. With the advent of additive manufacturing (three-dimensional printing) and its use in conjunction with biomaterial regenerative strategies and stem cell research, there is an increased potential capacity to alleviate such limitations. This review focuses on the current capabilities of additive manufacturing platforms, completed research and potential for future uses in the treatment of craniomaxillofacial injuries, with an in-depth discussion of regeneration of the periodontal complex and teeth.

  11. Three-dimensional supersonic vortex breakdown

    Science.gov (United States)

    Kandil, Osama A.; Kandil, Hamdy A.; Liu, C. H.

    1993-01-01

    Three-dimensional supersonic vortex-breakdown problems in bound and unbound domains are solved. The solutions are obtained using the time-accurate integration of the unsteady, compressible, full Navier-Stokes (NS) equations. The computational scheme is an implicit, upwind, flux-difference splitting, finite-volume scheme. Two vortex-breakdown applications are considered in the present paper. The first is for a supersonic swirling jet which is issued from a nozzle into a supersonic uniform flow at a lower Mach number than that of the swirling jet. The second is for a supersonic swirling flow in a configured circular duct. In the first application, an extensive study of the effects of grid fineness, shape and grid-point distribution on the vortex breakdown is presented. Four grids are used in this study and they show a substantial dependence of the breakdown bubble and shock wave on the grid used. In the second application, the bubble-type and helix-type vortex breakdown have been captured.

  12. Three-dimensional laparoscopy: Principles and practice

    Directory of Open Access Journals (Sweden)

    Rakesh Y Sinha

    2017-01-01

    Full Text Available The largest challenge for laparoscopic surgeons is the eye–hand coordination within a three-dimensional (3D scene observed on a 2D display. The 2D view on flat screen laparoscopy is cerebrally intensive. The loss of binocular vision on a 2D displa