WorldWideScience

Sample records for solution conditions ph

  1. THE PREDICTION OF pH BY GIBBS FREE ENERGY MINIMIZATION IN THE SUMP SOLUTION UNDER LOCA CONDITION OF PWR

    Directory of Open Access Journals (Sweden)

    HYOUNGJU YOON

    2013-02-01

    Full Text Available It is required that the pH of the sump solution should be above 7.0 to retain iodine in a liquid phase and be within the material compatibility constraints under LOCA condition of PWR. The pH of the sump solution can be determined by conventional chemical equilibrium constants or by the minimization of Gibbs free energy. The latter method developed as a computer code called SOLGASMIX-PV is more convenient than the former since various chemical components can be easily treated under LOCA conditions. In this study, SOLGASMIX-PV code was modified to accommodate the acidic and basic materials produced by radiolysis reactions and to calculate the pH of the sump solution. When the computed pH was compared with measured by the ORNL experiment to verify the reliability of the modified code, the error between two values was within 0.3 pH. Finally, two cases of calculation were performed for the SKN 3&4 and UCN 1&2. As results, pH of the sump solution for the SKN 3&4 was between 7.02 and 7.45, and for the UCN 1&2 plant between 8.07 and 9.41. Furthermore, it was found that the radiolysis reactions have insignificant effects on pH because the relative concentrations of HCl, HNO3, and Cs are very low.

  2. Effects of solution pH and complexing reagents on uranium and thorium desorption under saturated equilibrium conditions

    International Nuclear Information System (INIS)

    Wang, Yug-Yea; Yu, C.

    1992-01-01

    Three contaminated bulk surface soils were used for investigating the effect of solution pH and complexing reagents on uranium and thorium desorption. At a low solution pH, the major chemical species of uranium and thorium, uranyl UO 2 +2 , thorium dihydroxide Th(OH) 2 +2 , and thorium hydroxide Th(OH) +3 , tend to form complexes with acetates in the solution phase, which increases the fractions of uranium and thorium desorbed into this phase. At a high solution pH, important uranium and thorium species such as uranyl tricarbonate complex UO 2 (CO) 33 -4 and thorium tetrahydroxide complex Th(OH) 4 tend to resist complexation with acetates. The presence of complexing reagents in solution can release radionuclides such as uranium and/or thorium from the soil to the solution by forming soluble complexes. Sodium bicarbonate (NaHCO 3 ) and diethylenetriaminepentaacetic acid (DTPA) are strong complex formers that released 38% to 62% of total uranium activity and 78% to 86% of total thorium activity, respectively, from the soil samples investigated. Solutions of 0.1 molar sodium nitrate (NaNO 3 ) and 0.1 molar sodium sulfate (Na 2 SO 4 ) were not effective complex formers with uranium and thorium under the experimental conditions. Fractions of uranium and thorium desorbed by 0.15g/200ml humic acid ranged from 4.62% to 6.17% and 1.59% to 7.09%, respectively. This work demonstrates the importance of a knowledge of solution chemistry in investigating the desorption of radionuclides

  3. Electrocatalytic hydrogen evolution under densely buffered neutral pH conditions

    KAUST Repository

    Shinagawa, Tatsuya

    2015-08-18

    Under buffered neutral pH conditions, solute concentrations drastically influence the hydrogen evolution reaction (HER). The iR-free HER performance as a function of solute concentration was found to exhibit a volcano-shaped trend in sodium phosphate solution at pH 5, with the maximum occurring at 2 M. A detailed microkinetic model that includes calculated activity coefficients, solution resistance, and mass-transport parameters accurately describes the measured values, clarifying that the overall HER performance is predominantly governed by mass-transport of slow phosphate ions (weak acid). In the HER at the optimum concentration of approximately 2 M sodium phosphate at pH 5, our theoretical model predicts that the concentration overpotential accounts for more than half of the required overpotential. The substantial concentration overpotential would originate from the electrolyte property, suggesting that the proper electrolyte engineering will result in an improved apparent HER performances. The significance of concentration overpotential shown in the study is critical in the advancement of electrocatalysis, biocatalysis, and photocatalysis.

  4. Electrocatalytic hydrogen evolution under densely buffered neutral pH conditions

    KAUST Repository

    Shinagawa, Tatsuya; Takanabe, Kazuhiro

    2015-01-01

    Under buffered neutral pH conditions, solute concentrations drastically influence the hydrogen evolution reaction (HER). The iR-free HER performance as a function of solute concentration was found to exhibit a volcano-shaped trend in sodium phosphate solution at pH 5, with the maximum occurring at 2 M. A detailed microkinetic model that includes calculated activity coefficients, solution resistance, and mass-transport parameters accurately describes the measured values, clarifying that the overall HER performance is predominantly governed by mass-transport of slow phosphate ions (weak acid). In the HER at the optimum concentration of approximately 2 M sodium phosphate at pH 5, our theoretical model predicts that the concentration overpotential accounts for more than half of the required overpotential. The substantial concentration overpotential would originate from the electrolyte property, suggesting that the proper electrolyte engineering will result in an improved apparent HER performances. The significance of concentration overpotential shown in the study is critical in the advancement of electrocatalysis, biocatalysis, and photocatalysis.

  5. Effect of pH value of applied solution on radioiodine sorption by soils

    International Nuclear Information System (INIS)

    Szabova, T.

    1976-01-01

    Sorption of radioiodine by soils was followed under static conditions at different pH values of the initial solution in five soil types. Sorption of radioiodine by soils is affected by the amount of the organic mass and by the pH of solutions. With the same pH, soils containing a higher amount of the organic mass absorb more radioiodine. The highest sorption percentage of 131 I - for all pH values was found in meadow chernozem soil and the lowest in the rendzina and in carboniferous meadow soils. The highest sorption of 131 I - for degraded chernozem, meadow chernozem soils and brown soil was recorded at pH 5 and for carboniferous meadow soil and rendzina at pH 7. (author)

  6. A new fluorescent pH probe for extremely acidic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Jiang, Zheng [School of Life Science, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Xiao, Yu [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Bi, Fu-Zhen [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Miao, Jun-Ying, E-mail: miaojy@sdu.edu.cn [School of Life Science, Shandong University, Jinan 250100 (China); Zhao, Bao-Xiang, E-mail: bxzhao@sdu.edu.cn [School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2014-04-01

    A new coumarin-based fluorescent probe can detect highly acidic conditions in both solution and bacteria with high selectivity and sensitivity. Highlights: • A new fluorescence probe for very low pH was synthesized and characterized. • The probe can monitor pH in solution and bacteria. • The two-step protonation of N atoms of the probe leads to fluorescence quenching. Abstract: A novel turn-off fluorescent probe based on coumarin and imidazole moiety for extremely acidic conditions was designed and developed. The probe with pKa = 2.1 is able to respond to very low pH value (below 3.5) with high sensitivity relying on fluorescence quenching at 460 nm in fluorescence spectra or the ratios of absorbance maximum at 380 nm to that at 450 nm in UV–vis spectra. It can quantitatively detect pH value based on equilibrium equation, pH = pKa -log[(Ix - Ib)/(Ia - Ix)]. It had very short response time that was less than 1 min, good reversibility and nearly no interference from common metal ions. Moreover, using ¹H NMR analysis and theoretical calculation of molecular orbital, we verified that a two-step protonation process of two N atoms of the probe leaded to photoinduced electron transfer (PET), which was actually the mechanism of the fluorescence quenching phenomenon under strongly acidic conditions. Furthermore, the probe was also applied to imaging strong acidity in bacteria, E.coli and had good effect. This work illustrates that the new probe could be a practical and ideal pH indicator for strongly acidic conditions with good biological significance.

  7. Influence of pH of spray solution on optoelectronic properties of cadmium oxide thin films

    International Nuclear Information System (INIS)

    Hodlur, R. M.; Rabinal, M. K.

    2015-01-01

    Highly conducting transparent cadmium oxide thin films were prepared by the conventional spray pyrolysis technique. The pH of the spray solution is varied by adding ammonia/hydrochloric acid. The effect of pH on the morphology, crystallinity and optoelectronic properties of these films is studied. The structural analysis showed all the films in the cubic phase. For the films with pH < 7 (acidic condition), the preferred orientation is along the (111) direction and for those with pH >7 (alkaline condition), the preferred orientation is along the (200) direction. A lowest resistivity of 9.9 × 10 −4 Ω·cm (with carrier concentration = 5.1 × 10 20 cm −3 , mobility = 12.4 cm 2 /(V·s)) is observed for pH ≈ 12. The resistivity is tuned almost by three orders of magnitude by controlling the bath pH with optical transmittance more than 70%. Thus, the electrical conductivity of CdO films could be easily tuned by simply varying the pH of the spray solution without compromising the optical transparency. (paper)

  8. Effect of nitrogen form and pH of nutrient solution on the changes in pH and EC of spinach rhizosphere in hydroponic culture

    OpenAIRE

    M. Parsazadeh; N. Najafi

    2011-01-01

    In this study, the effect of nitrate to ammonium ratio and pH of nutrient solution on the changes in pH and EC of rhizosphere during spinach growth period in perlite culture, under greenhouse conditions, was investigated. A split factorial experiment in a completely randomized design with four replications was conducted with three factors including nutrient solution’s pH in three levels (4.5, 6.5 and 8), nitrate to ammonium ratio of nutrient solution in five levels (100:0, 75:25, 50:50, 25:75...

  9. pH dependent green synthesis of gold nanoparticles by completely C6-carboxylated curdlan under high temperature and various pH conditions.

    Science.gov (United States)

    Qiu, Wen-Yi; Wang, Kai; Wang, Yao-Yao; Ding, Zhi-Chao; Wu, Li-Xia; Cai, Wu-Dan; Yan, Jing-Kun

    2018-01-01

    A C6-carboxylated curdlan (C6-Cc) obtained from 4-acetamido-TEMPO-mediated oxidation of curdlan was used both as a reducing and stabilizing agent for green synthesis of pH-responsive AuNPs, which was carried out by controlling the pH of the C6-Cc solution at a high temperature (100°C). C6-Cc presented a semi-flexible random coil chain in the aqueous medium at pH 5.5 and became more expanded and rigid in alkaline conditions (pH 7.1-12.0), though the primary chemical structure of C6-Cc was virtually unchanged with the pH variation. The AuNPs prepared with C6-Cc at various pHs were characterized by various instrumental measurements. The shapes and sizes of AuNPs were found to be strongly dependent on the pH of the C6-Cc solution. The C6-Cc-decorated AuNPs exhibited a more well-dispersed spherical morphology with smaller particle sizes under alkaline conditions (pH 7.1-12.0). Through this study, a facile, simple, and green method has been demonstrated for preparation of stimuli-sensitive AuNPs using biocompatible polyanionic polysaccharides. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Solution and surface chemistry of the Se(IV)-Fe(0) reactions: Effect of initial solution pH.

    Science.gov (United States)

    Xia, Xuefen; Ling, Lan; Zhang, Wei-Xian

    2017-02-01

    Aspects of solution and solid-phase reactions between selenite (Se(IV)) and nanoscale zero-valent iron (nZVI) were investigated. Experimental results on the effects of initial solution pH, formation and evolution of nZVI corrosion products, and speciation of selenium in nZVI were presented. In general, the rate of Se(IV) removal decreases with increasing initial pH. The observed rate constants of Se(IV) removal decreased from 0.3530 to 0.0364 min -1 as pH increased from 4.0 to 10.0. Composition and morphology of nZVI corrosion products and selenium species were characterized using scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Results confirmed that Se(IV) was reduced to Se(0) and Se(-II) by nZVI. Lower solution pH favored further reduction of Se(0) to Se(-II). Amorphous FeOOH, magnetite/maghemite (Fe 3 O 4 /γ-Fe 2 O 3 ) and ferrous hydroxide (Fe(OH) 2 ) were identified as the main corrosion products. Under alkaline conditions, the corrosion products were mainly of Fe(OH) 2 along with small amounts of Fe 3 O 4 , while nZVI in acidic solutions was oxidized to mostly Fe 3 O 4 and amorphous FeOOH. Furthermore, these corrosion products acted as intermediates for electron transfer and reactive/sorptive sites for Se(IV) adsorption and reduction, thus played a crucial role in the removal of aqueous Se(IV). Copyright © 2016. Published by Elsevier Ltd.

  11. Computer model of hydroponics nutrient solution pH control using ammonium.

    Science.gov (United States)

    Pitts, M; Stutte, G

    1999-01-01

    A computer simulation of a hydroponics-based plant growth chamber using ammonium to control pH was constructed to determine the feasibility of such a system. In nitrate-based recirculating hydroponics systems, the pH will increase as plants release hydroxide ions into the nutrient solution to maintain plant charge balance. Ammonium is an attractive alternative to traditional pH controls in an ALSS, but requires careful monitoring and control to avoid overdosing the plants with ammonium. The primary advantage of using NH4+ for pH control is that it exploits the existing plant nutrient uptake charge balance mechanisms to maintain solution pH. The simulation models growth, nitrogen uptake, and pH of a l-m2 stand of wheat. Simulation results indicated that ammonium-based control of nutrient solution pH is feasible using a proportional integral controller. Use of a 1 mmol/L buffer (Ka = 1.6 x 10(-6)) in the nutrient solution is required.

  12. Corrosion studies of thermally sensitised AGR fuel element brace in pH7 and pH9.2 borate solutions

    International Nuclear Information System (INIS)

    Tyfield, S.P.; Smith, C.A.

    1987-04-01

    Brace and cladding of AGR fuel elements sensitised in reactor are susceptible to intergranular and crevice corrosion, which may initiate in the pH7 borate pond storage environment of CEGB/SSEB stations. This report considers the benefit in corrosion control that is provided by raising the pond solution pH to 9.2, whilst maintaining the boron level at 1250 gm -3 . The greater corrosion protection provided by pH9.2 solution compared to the pH7 borate solution is demonstrated by a series of tests with non-active laboratory sensitised brace samples exposed to solutions dosed with chloride or sulphate in order to promote localised corrosion. The corrosion tests undertaken consisted of 5000 hour immersions at 32 0 C and shorter term electrochemically monitored experiments (rest potential, impedance, anodic current) generally conducted at 22 0 C. The pH9.2 solution effectively inhibited the initiation of crevice and intergranular corrosion in the presence of low levels of chloride and sulphate, whereas the pH7 solution did not always do so. However, the pH9.2 solution, dosed with 40 gm -3 chloride, failed to suppress fully crevice corrosion initiated in unborated 40 gm -3 chloride solution at 22 0 C. Fluoride is not deleterious at low levels ∼ 10 gm -3 in the borate solutions. The significant improvement in corrosion control demonstrated for the change from pH7 to pH9.2 borate solution on laboratory sensitised brace samples should ideally be confirmed using complete irradiated AGR fuel elements. (U.K.)

  13. The Effects of Electroless Nickel Plating Bath Conditions on Stability of Solution and Properties of Deposit

    International Nuclear Information System (INIS)

    Huh, Jin; Lee, Jae Ho

    2000-01-01

    Electroless depositions of nickel were conducted in different bath conditions to find optimum conditions of electroless nickel plating at low operating temperature and pH. The effect of complexing reagent on stability of plating solution was investigated. Sodium citrate complexed plating solution is more stable than sodium pyrophosphate complexed solution. The effects of nickel salt concentration, reducing agent, complexing agent and inhibitor on deposition rate was investigated. The effects of pH on deposition rate and content of phosphorous in deposited nickel were also analyzed. Electroless deposited nickel become crystallized with increasing pH due to lower phosphorous content. In optimum operating bath condition, deposition rate was 7 μm/hr at 60 .deg. C and pH 10.0 without stabilizer. The rate was decreased with stabilizer concentration

  14. Effect of initial pH and temperature of iron salt solutions on formation of magnetite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Gnanaprakash, G. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Mahadevan, S. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Jayakumar, T. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Kalyanasundaram, P. [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India); Philip, John [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)]. E-mail: philip@igcar.gov.in; Raj, Baldev [Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2007-05-15

    We report the effect of initial pH and temperature of iron salt solutions on formation of magnetite (Fe{sub 3}O{sub 4}) nanoparticles during co-precipitation. We synthesized nanoparticles by keeping the initial pH at 0.7, 1.5, 3.0, 4.7, 5.7, 6.7 for two different temperatures of 30 and 60 deg. C. When the initial pH (prior to alkali addition) of the salt solution was below 5, the nanoparticles formed were 100% spinel iron oxide. Average size of the magnetite particles increases with initial pH until ferrihydrite is formed at a pH of 3 and the size remains the same till 4.7 pH. The percentage of goethite formed along with non-stoichiometric magnetite was 35 and 78%, respectively, when the initial pH of the solution was 5.7 and 6.7. As the reaction temperature was increased to 60 deg. C, maintaining a pH of 6.7, the amount of goethite increased from 78 to 100%. These results show that the initial pH and temperature of the ferrous and ferric salt solution before initiation of the precipitation reaction are critical parameters controlling the composition and size of nanoparticles formed. We characterize the samples using X-ray diffraction, transmission electron microscopy and vibrating sample magnetometer. The results of the present work provide the right conditions to synthesis pure magnetite nanoparticles, without goethite impurities, through co-precipitation technique for ferrofluid applications.

  15. Effect of Aging Temperature on Corrosion Behavior of Sintered 17-4 PH Stainless Steel in Dilute Sulfuric Acid Solution

    Science.gov (United States)

    Szewczyk-Nykiel, Aneta; Kazior, Jan

    2017-07-01

    The general corrosion behavior of sintered 17-4 PH stainless steel processed under different processing conditions in dilute sulfuric acid solution at 25 °C was studied by open-circuit potential measurement and potentiodynamic polarization technique. The corrosion resistance was evaluated based on electrochemical parameters, such as polarization resistance, corrosion potential, corrosion current density as well as corrosion rate. The results showed that the precipitation-hardening treatment could significantly improve the corrosion resistance of the sintered 17-4 PH stainless steel in studied environment. As far as the influence of aging temperature on corrosion behavior of the sintered 17-4 PH stainless steel is concerned, polarization resistance and corrosion rate are reduced with increasing aging temperature from 480 up to 500 °C regardless of the temperature of solution treatment. It can be concluded that the highest corrosion resistance in 0.5 M H2SO4 solution exhibits 17-4 PH after solution treatment at 1040 °C followed by aging at 480 °C.

  16. Growth and Tissue Elemental Composition Response of Butterhead Lettuce (Lactuca sativa, cv. Flandria to Hydroponic Conditions at Different pH and Alkalinity

    Directory of Open Access Journals (Sweden)

    Tyler S. Anderson

    2017-07-01

    Full Text Available Biomass and tissue elemental differences were quantified for lettuce grown in deep-water conventional hydroponic conditions at two pH and alkalinity conditions. Nutrient solutions were created using inorganic salts and either reverse osmosis (RO water or municipal water with high alkalinity. Three treatments were evaluated: (a nutrient solution created with reverse osmosis (RO water and maintained at pH 5.8 (H5; (b same as H5 but maintained at pH 7.0 (H7; and (c nutrient solution created using municipal water and maintained at pH 7.0, referred to as HA7. Averaged across three trials, the HA7 and H7 treatments produced 26% less shoot fresh weight (FW than the H5 treatment with an 18% reduction in dry weight (DW. The H5 treatment had the least biomass in root FW and DW. In tissue elemental analyses, both the pH 7.0 treatments showed lower concentrations than H5 in Cu, N, Mo, and Sr, and increased concentrations in Ba, Mg, Na, and Zn. There were no differences in Al, C, Ca, Fe, K, Mn, Ni, P, S, and Si concentrations among treatments (p = 0.05. The results from this experiment can be used to isolate the effects of pH and alkalinity in aquaponic conditions where pH and alkalinity will mimic HA7 conditions.

  17. X-ray absorption spectroscopic study of trivalent and tetravalent actinides in solution at varying pH values

    Energy Technology Data Exchange (ETDEWEB)

    Brendebach, B.; Banik, N.L.; Marquardt, C.M.; Rothe, J.; Denecke, M.A.; Geckeis, H. [Forschungszentrum Karlsruhe (Germany). Inst. fuer Nukleare Entsorgung

    2009-07-01

    We perform X-ray absorption spectroscopy (XAS) investigations to monitor the stabilization of redox sensitive trivalent and tetravalent actinide ions in solution at acidic conditions in a pH range from 0 to 3 after treatment with holding reductants, hydroxylamine hydrochloride (NH{sub 2}OHHCl) and Rongalite (sodium hydroxymethanesulfinate, CH{sub 3}NaO{sub 3}S). X-ray absorption near edge structure (XANES) measurements clearly demonstrate the stability of the actinide species for several hours under the given experimental conditions. Hence, structural parameters can be accurately derived by extended X-ray absorption fine structure (EXAFS) investigations. The coordination structure of oxygen atoms belonging to water ligands surrounding the actinide ions does not change with increasing pH value (approximately 11 O atoms at 2.42 A in the case of U(IV) at pH 1, 9 0 atoms at 2.52 A for Np(III) at pH 1.5, and 10 O atoms at 2.49 A for Pu(III) up to pH 3), indicating that hydrolysis reactions are suppressed under the given chemical conditions. (orig.)

  18. Characterizing the correlation between dephosphorization and solution pH in a calcined water treatment plant sludge.

    Science.gov (United States)

    Zhou, Zhenming; Liu, Qidi; Li, Shuwen; Li, Fei; Zou, Jing; Liao, Xiaobin; Yuan, Baoling; Sun, Wenjie

    2018-04-26

    This study focused on characterizing the correlation between the dephosphorization process of calcined water treatment plant sludge (C-WTPS) and the solution initial pH in batch experiments. The specific aim was to illustrate the effect of different initial pH on the adsorption and desorption of phosphorous in C-WTPS. In addition, the effects of solution initial pH on the release of ammonia nitrogen and total organic carbon (TOC) from C-WTPS and the change of pH after adsorption were also investigated. The results demonstrated that the initial pH significantly influenced the adsorption of phosphorus on C-WTPS. When initial pH was increased from 3 to 10, the phosphorous absorption capacity reduced by 76.5%. Especially, when the initial pH reached to 11, the phosphorus adsorption capacity became a negative value, indicating that C-WTPS released phosphorus into the solution. The addition of C-WTPS to the solution had little impact on the initial pH of the solution. The absorbed phosphorous on C-WTPS was relatively stable in the pH range of 3 to 10. Nevertheless, when the solution pH was higher than 11, it can be easily released into the solution. Furthermore, by comparison with WTPS, C-WTPS released less ammonia nitrogen and TOC into the solution and adsorbed more phosphorus from the solution in the experimental pH range. Therefore, C-WTPS is more suitable to serve as a cost-effective sorbent for phosphorus removal.

  19. Kinetic Rate Law Parameter Measurements on a Borosilicate Waste Glass: Effect of Temperature, pH, and Solution Composition on Alkali Ion Exchange

    International Nuclear Information System (INIS)

    Pierce, Eric M.; McGrail, B PETER.; Icenhower, J P.; Rodriguez, Elsa A.; Steele, Jackie L.; Baum, Steven R.

    2004-01-01

    The reaction kinetics of glass is controlled by matrix dissolution and ion exchange (IEX). Dissolution of an alkali-rich simulated borosilicate waste glass was investigated using single-pass flow-through (SPFT) experiments. Experiments were conducted as a function of temperature, pH, and solution composition by varying the SiO 2 (aq) activity in the influent solution. Results showed that under dilute conditions matrix dissolution increased with increasing pH and temperature, and decreased with increasing SiO 2 (aq) activity. IEX rates decreased with increasing pH and temperature, and increased with increasing SiO 2 (aq) activity. Over the solution composition range interrogated in this study the dominant dissolution mechanism changed from matrix dissolution to IEX. These results suggest that ''secondary'' reactions may become dominant under certain environmental conditions and emphasize the need to incorporate these reactions into dissolution rate models

  20. Estimation of Hydrazine Decomposition on Measuring the High-Temperature pH in Hydrazine/ETA Solutions at 553 K

    International Nuclear Information System (INIS)

    Hwang, Jae Sik; Yeon, Jei Won; Yun, Myung Hee; Song, Kyu Seok; Lee, Sang Ill

    2010-01-01

    Hydrazine is one of the most excellent oxygen scavengers used in the secondary circuit of nuclear power plants. Furthermore, in some pants, the hydrazine is used as a source of hydrogen required to suppress radiolysis of the coolant water in the primary loop. When hydrazine was exposed in the high temperature and high pressure water, it can be decomposed into the various products such as NH 3 , N 2 , H 2 , and NO 3 ions. As the result, the pH of solution containing hydrazine in the condition of the high temperature and high pressure can be changed by those decomposed products. In the present work, we investigated the decomposition behavior of hydrazine in ETA (ethanol amine) solution. In addition, we measured the high temperature pH at 553 K on the various hydrazine/ETA solutions for confirming the applicability of the yttria stabilized zirconia (YSZ)- based pH electrode in secondary circuit of the nuclear power plants

  1. Semantic conditioning of salivary pH for communication.

    Science.gov (United States)

    Ruf, Carolin A; De Massari, Daniele; Wagner-Podmaniczky, Franziska; Matuz, Tamara; Birbaumer, Niels

    2013-10-01

    Semantic conditioning of salivary pH was investigated as a new paradigm for binary communication. In a sample of eleven healthy participants, affirmation or negation of presented statements were paired with milk and lemon to condition changes in salivary pH level. Significant differences between the conditioned reactions were found at the group level. However, the analysis of pH changes on single-subject level revealed significant differences between affirmative and negative responses to the presented statements only for isolated samples in few participants. When classifying a change in pH value of more than .01 as correct response to a statement, only responses to affirmative statements reached mean accuracies of more than 60%. Improvements in the paradigm are necessary before testing it with the critical target population of patients to prove its profit for basic yes/no communication in case no other reliable means of communication could be preserved. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Dansyl-8-aminoquinoline as a sensitive pH fluorescent probe with dual-responsive ranges in aqueous solutions.

    Science.gov (United States)

    Zhang, Min; Zheng, Shuyu; Ma, Liguo; Zhao, Meili; Deng, Lengfang; Yang, Liting; Ma, Li-Jun

    2014-04-24

    A sensitive pH fluorescent probe based on dansyl group, dansyl-8-aminoquinoline (DAQ), has been synthesized. The probe showed dual-responsive ranges to pH changes, one range from 2.00 to 7.95 and another one from 7.95 to 10.87 in aqueous solution, as it showed pKa values of 5.73 and 8.56 under acid and basic conditions, respectively. Furthermore, the pH response mechanism of the probe was explored successfully by using NMR spectra. The results indicated that the responses of DAQ to pH changes should attribute to the protonation of the nitrogen atom in the dimethylamino group and deprotonation of sulfonamide group. Copyright © 2014. Published by Elsevier B.V.

  3. Influence of pH and oxygen content of buffer solutions on the corrosion behaviour of metallic materials

    International Nuclear Information System (INIS)

    Wiedemann, K.H.

    1977-05-01

    The application of solutions to the decontamination of materials in nuclear installations is based on the condition that their corrosion behaviour is clearly understood. Since electrochemical corrosion is due to cathodic and anodic partial reactions which are influenced in different ways by the pH of the solution and the oxygen content it is suggested that the results of electrochemical experiments with buffer solutions be used as a model for predicting the corrosion behaviour of materials in other solutions. In the tests described here potentio-kinetic current-potential-curves have been traced and galvanic corrosion tests have been made. The results obtained in ascorbic acid, potassium hydrogen phthalate, ammonium citrate and acetate, sodium and potassium tartrate, ammonium hydrogen phosphate, sodium carbonate, hexamethylene tetramin, ethylene diamine enable - on the basis of summarized current-potential-curves - the metals studied to be classified in four groups characterized by clear differences concerning the influence of pH on the corrosion behaviour. (Auth.)

  4. Effect of pH Upper Control Limit on Nutrient Solution Component and Water Spinach Growth under Hydroponics

    OpenAIRE

    Xuzhang Xue; Yinkun Li; Feng Li; Fang Zhang; Wenzhong Guo

    2015-01-01

    In this study, experiment with four levels of nutrient solution pH control upper limit was conducted to explore the optimal nutrient solution pH management scheme under hydroponics by evaluating the nutrient solution characters i.e., pH, Electric Conductivity (EC), nitrate, soluble phosphorus (soluble-P), water spinach growth and quality. The results showed that the nutrient solution pH was 8.2 and unsuitable for water spinach growth under the treatment with no pH regulation during the experi...

  5. The effect of pH on phosphorus availability and speciation in an aquaponics nutrient solution.

    Science.gov (United States)

    Cerozi, Brunno da Silva; Fitzsimmons, Kevin

    2016-11-01

    The interaction between the main ions in aquaponics nutrient solutions affects chemical composition and availability of nutrients, and nutrient uptake by plant roots. This study determined the effect of pH on phosphorus (P) speciation and availability in an aquaponics nutrient solution and used Visual MINTEQ to simulate P species and P activity. In both experimental and simulated results, P availability decreased with increase in pH of aquaponics nutrient solutions. According to simulations, P binds to several cations leaving less free phosphate ions available in solution. High pH values resulted in the formation of insoluble calcium phosphate species. The study also demonstrated the importance of organic matter and alkalinity in keeping free phosphate ions in solution at high pH ranges. It is recommended though that pH in aquaponics systems is maintained at a 5.5-7.2 range for optimal availability and uptake by plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Metal extraction from Cetraria islandica (L. Ach. lichen using low pH solutions

    Directory of Open Access Journals (Sweden)

    ANA A. CUCULOVIC

    2008-04-01

    Full Text Available Extraction of metals (K, Al, Ca, Mg, Fe, Cu, Ba, Zn, Mn and Sr from dry Cetraria islandica (L. Ach. lichen was performed using solutions similar to acid rain (solution A – H2SO4–HNO3–(NH42SO4 and solution B – H2SO4–HNO3–(NH42SO4–NH4NO3. The pH values of these solutions were 2.00, 2.58, 2.87, 3.28, and 3.75. Five consecutive extractions were performed with each solution. In all solutions, the extracted metal content, except Cu and Ca, was the highest in the first extract. The highest percentage of the metals desorbed in the first extraction was obtained using solutions with low pH values, 2.00, 2.58, and 2.87. The lowest percentage in the first extraction was obtained using solutions with pH 3.28 and 3.75, indicating influence of the H+ ion on the extraction. According to the results obtained, the investigated metals form two groups. The first group includes K, Al, Ca, Mg, and Fe. They were extracted in each of the five extractions at each of the pH values. The second group includes Ba, Zn, Mn, Cu, and Sr, which were not all extracted at each pH value. The first group yielded three types of extraction curves when the logarithms of extracted metal amounts were plotted as a function of the number of successive extractions. These effects indicate that three different positions (centres of metal ion accumulation exist in the lichen (due to sorption, complex formation, or other processes present in the tissues.

  7. Carbon steel corrosion under anaerobic-aerobic cycling conditions in near-neutral pH saline solutions - Part 1: Long term corrosion behaviour

    International Nuclear Information System (INIS)

    Sherar, B.W.A.; Keech, P.G.; Shoesmith, D.W.

    2011-01-01

    Highlights: → Anaerobic-aerobic cycling on pipeline steel forms two distinct surface morphologies. → Seventy-five percentage of the surface was covered by a black, compact layer ∼4.5 μm thick. → A tubercle, ∼3 to 4 mm in cross section, covered the remaining 25% of surface. → The tubercle cross section showed a single large pit ∼275 μm deep. - Abstract: The influence of anaerobic-aerobic cycling on pipeline steel corrosion was investigated in near-neutral carbonate/sulphate/chloride solution (pH 9) over 238 days. The corrosion rate increased and decreased as exposure conditions were switched between redox conditions. Two distinct corrosion morphologies were observed. The majority of the surface corroded uniformly to produce a black magnetite/maghemite layer approximately 4.5 μm thick. The remaining surface was covered with an orange tubercle, approximately 3-4 mm in cross section. Analysis of the tubercle cross section revealed a single large pit approximately 275 μm deep. Repeated anaerobic-aerobic cycling localized the corrosion process within this tubercle-covered pit.

  8. Spectroscopic determination of pH

    International Nuclear Information System (INIS)

    Faanu, A.; Glover, E.T.; Bailey, E.; Rochelle, C.

    2009-01-01

    A technique of measuring pH at temperature range of 20 - 70 0 C and high pressure conditions of 1 - 200 atmospheres has been developed by relating the ratio of absorbance peaks of indicator solutions (basic and acidic) as a function of pH, using ultraviolet-visible spectrophotometer. The pH values of the buffer solutions measured at 20 0 C and 70 0 C indicated slight temperature dependence, while the pressure had no effect. The pH of the buffer solutions increased with temperature with relative standard deviations in the range 0.4 - 0.5 % at 95 % confidence interval. The possible causes of the temperature dependence were attributed to changes in pH values as the temperature changed. (au)

  9. SPATIAL AND TEMPORAL PATTERN OF SOIL pH AND Eh AND THEIR IMPACT ON SOLUTE IRON CONTENT IN A WETLAND (TRANSDANUBIA, HUNGARY

    Directory of Open Access Journals (Sweden)

    SZALAI ZOLTÁN

    2008-06-01

    Full Text Available Land mosaics have direct and indirect influence on chemical reaction and redox condition of soils. The present paper deals with the relationship between some environmental factors (such as soil andvegetation patterns, micro-relief, water regime, temperature and incident solar radiation and the pH, Eh of soils and solute iron in a headwater wetland in Transdanubia, Hungary. Measurements have been taken in four different patches and along their boundaries: sedge (Carex vulpina, Carex riparia, three patches and two species, horsetail (Equisetum arvense, common nettle (Urtica dioica. Thespatial pattern of the studied parameters are influenced by the water regime, micro-topography, climatic conditions and by direct and indirect effects of vegetation. The indirect effect can be the shading, which has influence on soil temperature and on the incident solar radiation (PAR. Root respiration and excretion of organic acids appear as direct effects.. There have been measured individual pH and Eh characteristic in the studied patches. Soil Eh, pH and solute iron have shown seasonal dynamics. Higher redox potentials (increasingly oxidative conditions and higher pH values were measured between late autumn and early spring. The increasing physiological activity of plants causes lower pH and Eh and it leads to higher spatial differences. Although temperature is an essential determining factor for Eh and pH, but our results suggest it rather has indirect effectsthrough plants on wetlands.

  10. Considerations on prevention of phlebitis and venous pain from intravenous prostaglandin E(1) administration by adjusting solution pH: in vitro manipulations affecting pH.

    Science.gov (United States)

    Kohno, Emiko; Nishikata, Mayumi; Okamura, Noboru; Matsuyama, Kenji

    2008-01-01

    Prostaglandin E(1) (PGE(1); Alprostadil Alfadex) is a potent vasodilator and inhibitor of platelet aggregation used to treat patients with peripheral vascular disease. The main adverse effects of intravenous PGE(1) administration, phlebitis and venous pain, arise from the unphysiologically low pH of infusion solutions. When PGE(1) infusion solutions with a pH value greater then 6 are used, phlebitis and venous pain are considered to be avoidable. Beginning with a PGE(1) infusion solution with pH greater than 6, we add the amount of 7% sodium bicarbonate needed to bring the solution to pH 7.4 if phlebitis or venous pain develops. In the present study we established a convenient nomogram showing the relationship between the titratable acidity of various infusion solutions and the volume of 7% sodium bicarbonate required to attain pH 7.4 for preventing the phlebitis and venous pain associated with PGE(1) infusion.

  11. [Aluminum dissolution and changes of pH in soil solution during sorption of copper by aggregates of paddy soil].

    Science.gov (United States)

    Xu, Hai-Bo; Zhao, Dao-Yuan; Qin, Chao; Li, Yu-Jiao; Dong, Chang-Xun

    2014-01-01

    Size fractions of soil aggregates in Lake Tai region were collected by the low-energy ultrasonic dispersion and the freeze-desiccation methods. The dissolution of aluminum and changes of pH in soil solution during sorption of Cu2+ and changes of the dissolution of aluminum at different pH in the solution of Cu2+ by aggregates were studied by the equilibrium sorption method. The results showed that in the process of Cu2+ sorption by aggregates, the aluminum was dissoluted and the pH decreased. The elution amount of aluminum and the decrease of pH changed with the sorption of Cu2+, both increasing with the increase of Cu2+ sorption. Under the same conditions, the dissolution of aluminum and the decrease of pH were in the order of coarse silt fraction > silt fraction > sand fraction > clay fraction, which was negatively correlated with the amount of iron oxide, aluminum and organic matter. It suggested that iron oxide, aluminum and organic matters had inhibitory and buffering effect on the aluminum dissolution and the decrease of pH during the sorption of Cu2+.

  12. The effect of probe choice and solution conditions on the apparent photoreactivity of dissolved organic matter.

    Science.gov (United States)

    Maizel, Andrew C; Remucal, Christina K

    2017-08-16

    Excited triplet states of dissolved organic matter ( 3 DOM) are quantified directly with the species-specific probes trans,trans-hexadienoic acid (HDA) and 2,4,6-trimethylphenol (TMP), and indirectly with the singlet oxygen ( 1 O 2 ) probe furfuryl alcohol (FFA). Although previous work suggests that these probe compounds may be sensitive to solution conditions, including dissolved organic carbon concentration ([DOC]) and pH, and may quantify different 3 DOM subpopulations, the probes have not been systematically compared. Therefore, we quantify the apparent photoreactivity of diverse environmental waters using HDA, TMP, and FFA. By conducting experiments under ambient [DOC] and pH, with standardized [DOC] and pH, and with solid phase extraction isolates, we demonstrate that much of the apparent dissimilarity in photochemical measurements is attributable to solution conditions, rather than intrinsic differences in 3 DOM production. In general, apparent quantum yields (Φ 1 O 2 ≥ Φ 3 DOM,TMP ≫ Φ 3 DOM,HDA ) and pseudo-steady state concentrations ([ 1 O 2 ] ss > [ 3 DOM] ss,TMP > [ 3 DOM] ss,HDA ) show consistent relationships in all waters under standardized conditions. However, intrinsic differences in 3 DOM photoreactivity are apparent between DOM from diverse sources, as seen in the higher Φ 1 O 2 and lower Φ 3 DOM,TMP of wastewater effluents compared with oligotrophic lakes. Additionally, while conflicting trends in photoreactivity are observed under ambient conditions, all probes observe quantum yields increasing from surface wetlands to terrestrially influenced waters to oligotrophic lakes under standardized conditions. This work elucidates how probe selection and solution conditions influence the apparent photoreactivity of environmental waters and confirms that 3 DOM or 1 O 2 probes cannot be used interchangeably in waters that vary in [DOC], pH, or DOM source.

  13. From proton nuclear magnetic resonance spectra to pH. Assessment of {sup 1}H NMR pH indicator compound set for deuterium oxide solutions

    Energy Technology Data Exchange (ETDEWEB)

    Tynkkynen, Tuulia, E-mail: tuulia.tynkkynen@uku.fi [Laboratory of Chemistry, Department of Biosciences, University of Kuopio, PO Box 1627, 70211 Kuopio (Finland); Tiainen, Mika; Soininen, Pasi; Laatikainen, Reino [Laboratory of Chemistry, Department of Biosciences, University of Kuopio, PO Box 1627, 70211 Kuopio (Finland)

    2009-08-19

    In this study, a protocol for pH determination from D{sub 2}O samples using {sup 1}H NMR pH indicator compounds was developed and assessed by exploring the pH-dependency of 13 compounds giving pH-dependent {sup 1}H NMR signals. The indicators cover the pH range from pH* 0 to 7.2. Equations to transform the indicator chemical shifts to pH estimates are given here for acetic acid, formic acid, chloroacetic acid, dichloroacetic acid, creatine, creatinine, glycine, histidine, 1,2,4-triazole, and TSP (2,2,3,3-tetradeutero-3-(trimethylsilyl)-propionic acid). To characterize the method in presence of typical solutes, the effects of common metabolites, albumin and ionic strength were also evaluated. For the ionic strengths, the effects were also modelled. The experiments showed that the use of pH sensitive {sup 1}H NMR chemical shifts allows the pH determination of typical metabolite solutions with accuracy of 0.01-0.05 pH units. Also, when the ionic strength is known with accuracy better than 0.1 mol dm{sup -3} and the solute concentrations are low, pH{sub nmr}{sup *} (the NMR estimate of pH) can be assumed to be within 0.05 pH units from potentiometrically determined pH.

  14. pH control in the midgut of Aedesaegypti under different nutritional conditions.

    Science.gov (United States)

    Nepomuceno, Denise Barguil; Santos, Vânia Cristina; Araújo, Ricardo Nascimento; Pereira, Marcos Horácio; Sant'Anna, Maurício Roberto; Moreira, Luciano Andrade; Gontijo, Nelder Figueiredo

    2017-09-15

    Aedes aegypti is one of the most important disease vectors in the world. Because their gut is the first site of interaction with pathogens, it is important to understand A. aegypti gut physiology. In this study, we investigated the mechanisms of pH control in the midgut of A. aegypti females under different nutritional conditions. We found that unfed females have an acidic midgut (pH ∼6). The midgut of unfed insects is actively maintained at pH 6 regardless of the ingestion of either alkaline or acidic buffered solutions. V-ATPases are responsible for acidification after ingestion of alkaline solutions. In blood-fed females, the abdominal midgut becomes alkaline (pH 7.54), and the luminal pH decreases slightly throughout blood digestion. Only ingested proteins were able to trigger this abrupt increase in abdominal pH. The ingestion of amino acids, even at high concentrations, did not induce alkalinisation. During blood digestion, the thoracic midgut remains acidic, becoming a suitable compartment for carbohydrate digestion, which is in accordance with the higher alpha-glucolytic activity detected in this compartment. Ingestion of blood releases alkalising hormones in the haemolymph, which induce alkalinisation in ex vivo preparations. This study shows that adult A. aegypti females have a very similar gut physiology to that previously described for Lutzomyia longipalpis It is likely that all haematophagous Nematocera exhibit the same type of physiological behaviour. © 2017. Published by The Company of Biologists Ltd.

  15. Influence of pH, temperature and thermal treatment on site corrosion of SAE 304 steel in chlorinated solutions

    International Nuclear Information System (INIS)

    Konrad, I.B.

    1982-01-01

    The electrochemical behaviour and fracture morphology of homogenized and sensitized type SAE 304 stainless steel U bent specimens, in 3% NaCl solution, at pH=2.0 and pH=7.0 both at room temperature and 100 0 C was studied. Polarization curves, galvanostatic and potentiostatic experiments were run. It could be observed that high temperature and low pH favour transgranular cracking and longer sensitization times lower fracture time and tend to give rise to intergranular fracture. Light sensitization can produce transgranular cracking even at room temperature, when the homogenized alloy does not present stress-corrosion cracking for the same condition. (Author) [pt

  16. Temperature and pH driven association in uranyl aqueous solutions

    Directory of Open Access Journals (Sweden)

    M. Druchok

    2012-12-01

    Full Text Available An association behavior of uranyl ions in aqueous solutions is explored. For this purpose a set of all-atom molecular dynamics simulations is performed. During the simulation, the fractions of uranyl ions involved in dimer and trimer formations were monitored. To accompany the fraction statistics one also collected distributions characterizing average times of the dimer and trimer associates. Two factors effecting the uranyl association were considered: temperature and pH. As one can expect, an increase of the temperature decreases an uranyl capability of forming the associates, thus lowering bound fractions/times and vice versa. The effect of pH was modeled by adding H+ or OH- ions to a "neutral" solution. The addition of hydroxide ions OH- favors the formation of the associates, thus increasing bound times and fractions. The extra H+ ions in a solution produce an opposite effect, thus lowering the uranyl association capability. We also made a structural analysis for all the observed associates to reveal the mutual orientation of the uranyl ions.

  17. Biosynthesis of schwertmannite by Acidithiobacillus ferrooxidans cell suspensions under different pH condition

    Energy Technology Data Exchange (ETDEWEB)

    Liao Yuehua [Department of Environmental Engineering, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095 (China); Zhou Lixiang [Department of Environmental Engineering, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095 (China)], E-mail: lxzhou@njau.edu.cn; Liang Jianru; Xiong Huixin [Department of Environmental Engineering, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095 (China)

    2009-01-01

    Oxidation of FeSO{sub 4} solution with initial pH in the range of 1.40-3.51 by Acidithiobacillus ferrooxidans LX5 cell at 26 deg. C and subsequent precipitation of resulting Fe(III) were investigated in the present study. Results showed that the oxidation rate of Fe(II) was around 1.2-3.9 mmol l{sup -1} h{sup -1}. X-ray diffraction (XRD) indicated that the formed precipitates were composed of natrojarosite with schwertmannite when the initial pH was 3.51, while only schwertmannite was produced when initial pH was in the range of 1.60-3.44 and no precipitate occurred when initial pH {<=} 1.40. Scanning electron microscope (SEM) analyses showed that precipitates formed in solution with initial pH 3.51 were spherical particles of about 0.4 {mu}m in diameter and had a smooth surface, whereas precipitates in solution with initial pH {<=} 3.44 were spherical particles of approximately 1.0 {mu}m in diameter, having specific sea-urchin morphology. Specific surface area of the precipitates varied from 3.42 to 23.45 m{sup 2} g{sup -1}. X-ray fluorescence analyses revealed that schwertmannite formed in solution with initial pH in the range of 2.00-3.44 had similar elemental composition and could be expressed as Fe{sub 8}O{sub 8}(OH){sub 4.42}(SO{sub 4}){sub 1.79,} whereas Fe{sub 8}O{sub 8}(OH){sub 4.36}(SO{sub 4}){sub 1.82} and Fe{sub 8}O{sub 8}(OH){sub 4.29}(SO{sub 4}){sub 1.86} as its chemical formula when the initial pH was 1.80 and 1.60, respectively.

  18. Automated pH Control of Nutrient Solution in a Hydroponic Plant Growth System

    Science.gov (United States)

    Smith, B.; Dogan, N.; Aglan, H.; Mortley, D.; Loretan, P.

    1998-01-01

    Over, the years, NASA has played an important role in providing to and the development of automated nutrient delivery and monitoring, systems for growing crops hydroponically for long term space missions. One example are the systems used in the Biomass Production Chamber (BPC) at Kennedy Space Center (KSC). The current KSC monitoring system is based on an engineering workstation using standard analog/digital input/output hardware and custom written software. The monitoring system uses completely separate sensors to provide a check of control sensor accuracy and has the ability to graphically display and store data form past experiment so that they are available for data analysis [Fortson, 1992]. In many cases, growing systems have not been fitted with the kind of automated control systems as used at KSC. The Center for Food and Environmental Systems for Human Exploration of Space (CFESH) located on the campus of Tuskegee University, has effectively grown sweetpotatoes and peanuts hydroponically for the past five years. However they have adjusted the pH electrical conductivity and volume of the hydroponic nutrient solution only manually at times when the solution was to be replenished or changed out according to its protocol (e.g. one-week, two-week, or two-day cycle). But the pH of the nutrient solution flowing through the channel is neither known nor controlled between the update, change out, or replenishment period. Thus, the pH of the nutrient solution is not held at an optimum level over the span of the plant's growth cycle. To solve this dilemma, an automated system for the control and data logging of pH data relative to sweetpotato production using the nutrient film technique (NFT) has been developed, This paper discusses a microprocessor-based system, which was designed to monitor, control, and record the pH of a nutrient solution used for growing sweetpotatoes using NFT.

  19. A study of specific sorption of neptunium(V) on smectite in low pH solution

    International Nuclear Information System (INIS)

    Kozai, Naofumi; Ohnuki, Toshihiko; Matsumoto, Junko; Banba, Tsunetaka; Ito, Yoshimoto

    1996-01-01

    The 'specific sorption' of neptunium(V) on smectite, in other words, a strong sorption undesorbable by 1 M KCl, is studied with a combination of batch type sorption and desorption experiments over a pH range of 2 to 5. Six types of homoionic smectite (Li-, Na-, K-, Cs-, Mg-, and Ca-smectite) are used in this study. Distribution coefficients (K d ) of neptunium for smectite vary over a wide pH range; the maximum K d value of ∝300 cm 3 x g -1 at around pH 2 for Li- and Na-smectite and the minimum value of ∝2 cm 3 x g -1 for Cs-smectite. The specific sorption of neptunium depends on pH and on the affinity of the exchangeable cation for smectite; the lower the pH of solution or the affinity, the larger the specific sorption. The neptunium-smectite association varies with the elapse of contact time. Within the first day of the neptunium-smectite contact the neptunium sorbed on na-smectite at low pH is desorbable by 1 M KCl solution, and on the passage of time most of the neuptunium sorbed becomes undesorbable by KCl (the specific sorption). Hydronium ion in solution is sorbed on smectite at low pH and dissociates the exchangeable cation from smectite into solution, and the specific sorption of neuptunium increases with increasing the exchangeable cation that is dissociated from smectite. (orig.)

  20. Effect of Sulfur Concentration and PH Conditions on Akaganeite Formation: Understanding Akaganeite Formation Conditions in Yellowknife Bay, Gale Crater, Mars

    Science.gov (United States)

    Fox, A.; Peretyazhko, T.; Sutter, B.; Niles, P.; Ming, D. W.; Morris, R. V.

    2015-01-01

    The Chemistry and Mineralogy Instrument (CHEMIN) on board the Mars Science Laboratory (MSL) Curiosity Rover identified minor amounts of akaganeite (beta-FeOOH) at Yellowknife Bay, Mars. There is also evidence for akaganeite at other localities on Mars from the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM). Akaganeite is an iron(III) hydroxide with a hollandite- like structure and Cl in its tunnels. Terrestrial akaganeite usually forms in Cl-rich environments under acidic, oxidizing conditions. Previous studies of akaganeite have revealed that akaganeite formation is affected by the presence of sulfate (hereafter denoted as S. The prediction of circumneutral pH coupled with the detection of S at Yellowknife Bay dictate that work is needed to determine how S and pH together affect akaganeite formation. The goal of this work is to study how changes in both S concentration and pH influence akaganeite precipitation. Akaganeite formation was investigated at S/Cl molar ratios of 0, 0.017, 0.083, 0.17 and 0.33 at pH 1.5, 2, and 4. Results are anticipated to provide combined S concentration and pH constraints on akaganeite formation in Yellowknife Bay and elsewhere on Mars. Knowledge of solution pH and S concentrations can be utilized in understanding microbial habitability potential on the Martian surface.

  1. Electrochemical Corrosion Behavior of Carbon Steel and Hot Dip Galvanized Steel in Simulated Concrete Solution with Different pH Values

    Directory of Open Access Journals (Sweden)

    Wanchen XIE

    2017-08-01

    Full Text Available Hot dip galvanizing technology is now widely used as a method of protection for steel rebars. The corrosion behaviors of Q235 carbon steel and hot galvanized steel in a Ca(OH2 solution with a pH from 10 to 13 was investigated by electrode potential and polarization curves testing. The results indicated that carbon steel and hot galvanized steel were all passivated in a strong alkaline solution. The electrode potential of hot dip galvanized steel was lower than that of carbon steel; thus, hot dip galvanized steel can provide very good anodic protection for carbon steel. However, when the pH value reached 12.5, a polarity reversal occurred under the condition of a certain potential. Hot dip galvanized coating became a cathode, and the corrosion of carbon steel accelerated. The electrochemical behaviors and passivation abilities of hot dip galvanized steel and carbon steel were affected by pH. The higher the pH value was, the more easily they were passivated.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16675

  2. Effect of pH and phosphate on calcium carbonate polymorphs precipitated at near-freezing temperature

    NARCIS (Netherlands)

    Hu, Yu-Bin; Wolthers, Mariëtte; Wolf-Gladrow, Dieter A.; Nehrke, Gernot

    2015-01-01

    The effects of pH and phosphate on the precipitation of calcium carbonate polymorphs from aqueous solution were investigated. Experiments were carried out at near-freezing temperature and two different pH conditions (pH 13.4 and 9.0). At each pH condition, solutions having different concentrations

  3. Effect of Solution pH on the Adsorption of Paracetamol on Chemically Modified Activated Carbons

    Directory of Open Access Journals (Sweden)

    Valentina Bernal

    2017-06-01

    Full Text Available Paracetamol adsorption in acidic, neutral and basic media on three activated carbons with different chemistry surfaces was studied. A granular activated carbon (GAC was prepared from coconut shell; starting from this sample, an oxidized activated carbon (GACo was obtained by treating the GAC with a boiling solution of 6 M nitric acid, so to generate a greater number of oxygenated surface groups. In addition, a reduced activated carbon (GACr was obtained by heating the GAC at 1173 K, to remove the oxygenated surface groups. Paracetamol adsorption was higher for GACr due to the lower presence of oxygenated surface functional groups. Moreover, adsorption was highest at neutral pH. The magnitude of the interactions between paracetamol molecules and activated carbons was studied by measuring the immersion enthalpies of activated carbons in solution of paracetamol at different concentrations and pH values and by calculating the interaction enthalpy. The highest value was obtained for GACr in a paracetamol solution of 1000 mg L−1 at pH 7, confirming that paracetamol adsorption is favoured on basic activated carbons at pH values near to neutrality. Finally, the Gibbs energy changes confirmed the latter result, allowing explaining the different magnitudes of the interactions between paracetamol and activated carbons, as a function of solution pH.

  4. Ph3CCOOSnPh3.Ph3PO AND Ph3CCOOSnPh3.Ph3AsO: SYNTHESIS AND INFRARED STUDY

    Directory of Open Access Journals (Sweden)

    ABDOU MBAYE

    2014-08-01

    Full Text Available The mixture of ethanolic solutions of Ph3CCOOSnPh3 and Ph3PO or Ph3AsO gives Ph3CCOOSnPh3.Ph3PO and Ph3CCOOSnPh3.Ph3AsO adducts which have been characterized by infrared spectroscopy. A discrete structure is suggested for both, the environment around the tin centre being trigonal bipyramidal, the triphenylacetate anion behaving as a mondentate ligand.

  5. Integrating chemical imaging of cationic trace metal solutes and pH into a single hydrogel layer

    Energy Technology Data Exchange (ETDEWEB)

    Hoefer, Christoph [Department of Forest and Soil Sciences, Institute of Soil Research, University of Natural Resources and Life Sciences, Vienna, Konrad-Lorenz-Strasse 24, A-3430 Tulln (Austria); Santner, Jakob, E-mail: jakob.santner@boku.ac.at [Department of Forest and Soil Sciences, Institute of Soil Research, University of Natural Resources and Life Sciences, Vienna, Konrad-Lorenz-Strasse 24, A-3430 Tulln (Austria); Department of Crop Sciences, Division of Agronomy, University of Natural Resources and Life Sciences, Vienna, Konrad-Lorenz-Strasse 24, 3430 Tulln (Austria); Borisov, Sergey M. [Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9, A-8010, Graz (Austria); Wenzel, Walter W.; Puschenreiter, Markus [Department of Forest and Soil Sciences, Institute of Soil Research, University of Natural Resources and Life Sciences, Vienna, Konrad-Lorenz-Strasse 24, A-3430 Tulln (Austria)

    2017-01-15

    Gel-based, two-dimensional (2D) chemical imaging techniques are versatile methods for investigating biogeochemically active environments at high spatial resolution (sub-mm). State-of-the-art solute imaging techniques, such as diffusive gradients in thin films (DGT) and planar optodes (PO), employ passive solute sampling or sensing. Combining these methods will provide powerful tools for studying the biogeochemistry of biological niches in soils and sediments. In this study we aimed at developing a combined single-layer gel for direct pH imaging using PO and sampling of anionic and cationic solutes by DGT, with subsequent analysis of the bound solutes by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). We tested three ultra-thin (<100 μm) polyurethane-based gels, incorporating anion and cation binding materials and the fluorescent pH indicator DCIFODA (2′,7′-dichloro-5(6)-N-octadecyl-carboxamidofluorescein). Results showed that PO-based pH sensing using DCIFODA was impossible in the presence of the anion binding materials due to interferences with DCIFODA protonation. One gel, containing only a cation binding material and DCIFODA, was fully characterized and showed similar performance characteristics as comparable DGT-only gels (applicable pH range: pH 5–8, applicable ionic strength range: 1–20 mmol L{sup -1}, cation binding capacity ∼24 μg cm{sup −2}). The dynamic range for PO-based pH mapping was between pH 5.5 and 7.5 with t{sub 90} response time of ∼60 min. In a case study we demonstrated the gel's suitability for multi-analyte solute imaging and mapped pH gradients and concurrent metal solubility patterns in the rhizosphere of Salix smithiana. pH decreases in the rooted soil were co-localized with elevated solute fluxes of Al{sup 3+}, Co{sup 2+}, Cu{sup 2+}, Fe, Mn{sup 2+}, Ni{sup 2+} and Pb{sup 2+}, indicating pH-induced metal solubilisation. - Highlights: • Diffusive gradients in thin films (DGT) and planar

  6. Integrating chemical imaging of cationic trace metal solutes and pH into a single hydrogel layer

    International Nuclear Information System (INIS)

    Hoefer, Christoph; Santner, Jakob; Borisov, Sergey M.; Wenzel, Walter W.; Puschenreiter, Markus

    2017-01-01

    Gel-based, two-dimensional (2D) chemical imaging techniques are versatile methods for investigating biogeochemically active environments at high spatial resolution (sub-mm). State-of-the-art solute imaging techniques, such as diffusive gradients in thin films (DGT) and planar optodes (PO), employ passive solute sampling or sensing. Combining these methods will provide powerful tools for studying the biogeochemistry of biological niches in soils and sediments. In this study we aimed at developing a combined single-layer gel for direct pH imaging using PO and sampling of anionic and cationic solutes by DGT, with subsequent analysis of the bound solutes by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). We tested three ultra-thin (<100 μm) polyurethane-based gels, incorporating anion and cation binding materials and the fluorescent pH indicator DCIFODA (2′,7′-dichloro-5(6)-N-octadecyl-carboxamidofluorescein). Results showed that PO-based pH sensing using DCIFODA was impossible in the presence of the anion binding materials due to interferences with DCIFODA protonation. One gel, containing only a cation binding material and DCIFODA, was fully characterized and showed similar performance characteristics as comparable DGT-only gels (applicable pH range: pH 5–8, applicable ionic strength range: 1–20 mmol L"-"1, cation binding capacity ∼24 μg cm"−"2). The dynamic range for PO-based pH mapping was between pH 5.5 and 7.5 with t_9_0 response time of ∼60 min. In a case study we demonstrated the gel's suitability for multi-analyte solute imaging and mapped pH gradients and concurrent metal solubility patterns in the rhizosphere of Salix smithiana. pH decreases in the rooted soil were co-localized with elevated solute fluxes of Al"3"+, Co"2"+, Cu"2"+, Fe, Mn"2"+, Ni"2"+ and Pb"2"+, indicating pH-induced metal solubilisation. - Highlights: • Diffusive gradients in thin films (DGT) and planar optode (PO) imaging is combined. • A

  7. Electrolyte Engineering Toward Efficient Hydrogen Production Electrocatalysis with Oxygen-crossover Regulation under Densely Buffered Near-neutral pH Conditions

    KAUST Repository

    Shinagawa, Tatsuya; Takanabe, Kazuhiro

    2015-01-01

    This study tackles the core issues associated with near-neutral pH water splitting, particularly regarding electrolyte engineering in the electrocatalysis and product cross-over. We demonstrate that solute engineering has a major impact on water splitting electrocatalysis because the diffusion component, often not well integrated into performance descriptions, largely determines the overall performance. The hydrogen evolution reaction (HER) was investigated on Pt, Ni and NiMo catalysts in various concentrations of cations (Li+, K+, Na+) and anions (H2PO4−, HPO42−, PO43− and HCO3−) to describe its performance by quantifying kinetics, diffusion and solution resistance. In fact, the choice of electrolyte in terms of its identity and activity drastically altered the HER rate and oxygen mass-transport flux at near-neutral pH. Electrolyte properties (activity coefficient, kinematic viscosity and diffusion coefficient) accurately described the diffusion contribution, which can be easily isolated when a highly active Pt catalyst was used for the HER. By analyzing these properties, we maximized the HER rate on the Pt by tuning the solute concentration (typically 1.5 – 2.0 M). Moreover, the kinematic viscosity and oxygen solubility in such densely buffered conditions governed the oxygen mass-transport flux in the electrolyte, which in turn tuned the cross-over flux. At near-neutral pH, as high as 90 % selectivity toward the HER was achieved even under an oxygen saturated condition, where only a 40 mV overpotential was needed to achieve 10 mA cm−2 for the HER. This information can be regarded as an important milestone for achieving a highly efficient water splitting system at near-neutral pH.

  8. Electrolyte Engineering Toward Efficient Hydrogen Production Electrocatalysis with Oxygen-crossover Regulation under Densely Buffered Near-neutral pH Conditions

    KAUST Repository

    Shinagawa, Tatsuya

    2015-12-30

    This study tackles the core issues associated with near-neutral pH water splitting, particularly regarding electrolyte engineering in the electrocatalysis and product cross-over. We demonstrate that solute engineering has a major impact on water splitting electrocatalysis because the diffusion component, often not well integrated into performance descriptions, largely determines the overall performance. The hydrogen evolution reaction (HER) was investigated on Pt, Ni and NiMo catalysts in various concentrations of cations (Li+, K+, Na+) and anions (H2PO4−, HPO42−, PO43− and HCO3−) to describe its performance by quantifying kinetics, diffusion and solution resistance. In fact, the choice of electrolyte in terms of its identity and activity drastically altered the HER rate and oxygen mass-transport flux at near-neutral pH. Electrolyte properties (activity coefficient, kinematic viscosity and diffusion coefficient) accurately described the diffusion contribution, which can be easily isolated when a highly active Pt catalyst was used for the HER. By analyzing these properties, we maximized the HER rate on the Pt by tuning the solute concentration (typically 1.5 – 2.0 M). Moreover, the kinematic viscosity and oxygen solubility in such densely buffered conditions governed the oxygen mass-transport flux in the electrolyte, which in turn tuned the cross-over flux. At near-neutral pH, as high as 90 % selectivity toward the HER was achieved even under an oxygen saturated condition, where only a 40 mV overpotential was needed to achieve 10 mA cm−2 for the HER. This information can be regarded as an important milestone for achieving a highly efficient water splitting system at near-neutral pH.

  9. The passivation of calcite by acid mine water. Column experiments with ferric sulfate and ferric chloride solutions at pH 2

    Energy Technology Data Exchange (ETDEWEB)

    Soler, Josep M. [Institute of Earth Sciences ' Jaume Almera' (CSIC), Lluis Sole i Sabaris s/n, 08028 Barcelona, Catalonia (Spain); Institute of Environmental Assessment and Water Research (CSIC), Jordi Girona 18, 08034 Barcelona, Catalonia (Spain)], E-mail: jsoler@ija.csic.es; Boi, Marco [Institute of Earth Sciences ' Jaume Almera' (CSIC), Lluis Sole i Sabaris s/n, 08028 Barcelona, Catalonia (Spain); Institute of Environmental Assessment and Water Research (CSIC), Jordi Girona 18, 08034 Barcelona, Catalonia (Spain); Mogollon, Jose Luis [Institute of Earth Sciences ' Jaume Almera' (CSIC), Lluis Sole i Sabaris s/n, 08028 Barcelona, Catalonia (Spain); Instituto de Ciencias de la Tierra, Universidad Central de Venezuela, Caracas 1020-A (Venezuela, Bolivarian Republic of); Cama, Jordi; Ayora, Carlos [Institute of Earth Sciences ' Jaume Almera' (CSIC), Lluis Sole i Sabaris s/n, 08028 Barcelona, Catalonia (Spain); Institute of Environmental Assessment and Water Research (CSIC), Jordi Girona 18, 08034 Barcelona, Catalonia (Spain); Nico, Peter S.; Tamura, Nobumichi; Kunz, Martin [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2008-12-15

    Column experiments, simulating the behavior of passive treatment systems for acid mine drainage, have been performed. Acid solutions (HCl or H{sub 2}SO{sub 4}, pH 2), with initial concentrations of Fe(III) ranging from 250 to 1500 mg L{sup -1}, were injected into column reactors packed with calcite grains at a constant flow rate. The composition of the solutions was monitored during the experiments. At the end of the experiments (passivation of the columns), the composition and structure of the solids were measured. The dissolution of calcite in the columns caused an increase in pH and the release of Ca into the solution, leading to the precipitation of gypsum and Fe-oxyhydroxysulfates (Fe(III)-SO{sub 4}-H{sup +} solutions) or Fe-oxyhydroxychlorides (Fe(III)-Cl-H{sup +} solutions). The columns worked as an efficient barrier for some time, increasing the pH of the circulating solutions from 2 to {approx}6-7 and removing its metal content. However, after some time (several weeks, depending on the conditions), the columns became chemically inert. The results showed that passivation time increased with decreasing anion and metal content of the solutions. Gypsum was the phase responsible for the passivation of calcite in the experiments with Fe(III)-SO{sub 4}-H{sup +} solutions. Schwertmannite and goethite appeared as the Fe(III) secondary phases in those experiments. Akaganeite was the phase responsible for the passivation of the system in the experiments with Fe(III)-Cl-H{sup +} solutions.

  10. Effect of rhizosphere pH condition on cadmium movement in a soybean plant

    International Nuclear Information System (INIS)

    Ohya, T.; Tanoi, K.; Iikura, H.; Rai, H.; Nakanishi, T.M.

    2008-01-01

    To study the effect of rhizosphere pH condition on the cadmium uptake movement, 109 Cd, was applied as a radioisotope tracer to a soybean plant grown in a water culture at pH 4.5 or pH 6.5. The distribution of 109 Cd in the soybean plant was observed radiographically with an imaging plate (IP). The amount of Cd transported from the root to the upper part of the plant at pH 4.5 was approximately two times higher than that at pH 6.5. However, the movement of Cd in the upper part of the plant was similar under both pH conditions. The distribution of Cd inside the internodes at pH 4.5 also showed similar pattern to that at pH 6.5, suggesting that once Cd reached to the vessel of the root, the movement of Cd was not dependent on rhizosphere pH conditions. (author)

  11. Facet-Dependent Oxidative Goethite Growth As a Function of Aqueous Solution Conditions.

    Science.gov (United States)

    Strehlau, Jennifer H; Stemig, Melissa S; Penn, R Lee; Arnold, William A

    2016-10-04

    Nitroaromatic compounds are groundwater pollutants that can be degraded through reactions with Fe(II) adsorbed on iron oxide nanoparticles, although little is known about the evolving reactivity of the minerals with continuous pollutant exposure. In this work, Fe(II)/goethite reactivity toward 4-chloronitrobenzene (4-ClNB) as a function of pH, organic matter presence, and reactant concentrations was explored using sequential-spike batch reactors. Reaction rate constants were smaller with lower pH, introduction of organic matter, and diluted reactant concentrations as compared to a reference condition. Reaction rate constants did not change with the number of 4-ClNB spikes for all reaction conditions. Under all conditions, oxidative goethite growth was demonstrated through X-ray diffraction, magnetic characterization, and transmission electron microscopy. Nonparametric statistics were applied to compare histograms of lengths and widths of goethite nanoparticles as a function of varied solution conditions. The conditions that slowed the reaction also resulted in statistically shorter and wider particles than for the faster reactions. Additionally, added organic matter interfered with particle growth on the favorable {021} faces to a greater extent, with statistically reduced rate of growth on the tip facets and increased rate of growth on the side facets. These data demonstrate that oxidative growth of goethite in aqueous systems is dependent on major groundwater variables, such as pH and the presence of organic matter, which could lead to the evolving reactivity of goethite particles in natural environments.

  12. Determination of dissolution rates of spent fuel in carbonate solutions under different redox conditions with a flow-through experiment

    International Nuclear Information System (INIS)

    Roellin, S.; Spahiu, K.; Eklund, U.-B.

    2001-01-01

    Dissolution rates of spent UO 2 fuel have been investigated using flow-through experiments under oxidizing, anoxic and reducing conditions. For oxidizing conditions, approximately congruent dissolution rates were obtained in the pH range 3-9.3 for U, Np, Ba, Tc, Cs, Sr and Rb. For these elements, steady-state conditions were obtained in the flow rate range 0.02-0.3 ml min -1 . The dissolution rates were about 3 mg d -1 m -2 for pH>6. For pH 2 (g) saturated solutions dropped by up to four orders of magnitude as compared to oxidizing conditions. Because of the very low concentrations, only U, Pu, Am, Mo, Tc and Cs could be measured. For anoxic conditions, both the redox potential and dissolution rates increased approaching the same values as under oxidizing conditions

  13. Flux Balance Analysis of Escherichia coli under Temperature and pH Stress Conditions

    KAUST Repository

    Xu, Xiaopeng

    2015-05-12

    An interesting discovery in biology is that most genes in an organism are dispensable. That means these genes have minor effects on survival of the organism in standard laboratory conditions. One explanation of this discovery is that some genes play important roles in specific conditions and are essential genes under those conditions. E. coli is a model organism, which is widely used. It can adapt to many stress conditions, including temperature, pH, osmotic, antibiotic, etc. Underlying mechanisms and associated genes of each stress condition responses are usually different. In our analysis, we combined protein abundance data and mutant conditional fitness data into E. coli constraint-based metabolic models to study conditionally essential metabolic genes under temperature and pH stress conditions. Flux Balance Analysis was employed as the modeling method to analysis these data. We discovered lists of metabolic genes, which are E. coli dispensable genes, but conditionally essential under some stress conditions. Among these conditionally essential genes, atpA in low pH stress and nhaA in high pH stress found experimental evidences from previous studies. Our study provides new conditionally essential gene candidates for biologists to explore stress condition mechanisms.

  14. Comparative study of buffered 50% glycolic acid (pH 3.0) + 0.5% salicylic acid solution vs Jessner's solution in patients with acne vulgaris.

    Science.gov (United States)

    In Jae, Jeong; Dong Ju, Hyun; Dong Hyun, Kim; Yoon, Moon Soo; Lee, Hee Jung

    2017-11-21

    Superficial chemical peels are frequently used in acne vulgaris treatment. Although glycolic acid (GA) has been widely used in clinical practice, its pH ranges from 0.08-2.75 and thus should be neutralized after application to avoid burns. To evaluate treatment efficacy and safety of chemical peeling using buffered 50% GA (pH 3.0) + 0.5% salicylic acid (SA) solution that does not need to be neutralized in the treatment of acne vulgaris compared to the conventional peeling using Jessner's solution. We performed a prospective, randomized, evaluator-blind, split-face clinical trial. Twenty patients were randomized by assigning one side of each patient's face to receive a 50% GA (pH 3.0) + 0.5% SA peel (GA side) and the other side to receive the Jessner's solution (Jessner's solution side). All patients underwent 2 sessions of treatment spaced 2 weeks apart. Lesion count, acne severity, subjective efficacy assessment, and side effects were evaluated. The total lesion count was significantly reduced for the GA and Jessner's solution sides (P  .05). The GA side had fewer side effects than the Jessner's solution side. The results of this study suggest that chemical peeling using the 50% GA (pH 3.0) + 0.5% SA solution can be as effective and convenient as the conventional peeling using Jessner's solution in the treatment of acne vulgaris and may show fewer adverse events than the conventional peeling. © 2017 Wiley Periodicals, Inc.

  15. Gold sorption from aqueous solutions by hydroxides and oxides at conditions of complex formation and oxidation-reduction

    International Nuclear Information System (INIS)

    Novikov, A.I.; Shekoturova, E.K.; Ribalko, T.A.

    1986-01-01

    With using of radionuclide 198 Au 3+ at initial form 198 AuCl 4 - the sorption of Au 3+ at its concentrations from 1.27·10 3 till 1.9·10 -9 mol/l from solutions of NaClO 4 (0.1 and 1 mol/l), KHO 3 (0.1 and 1 mol/l), NaNO 3 (1 mol/l), NaCl(0.7-3 mol/l), KCl(0.01; 0.1 and 1 mol/l), NH 4 NO 3 (0.1 and 1 mol/l)NH 4 Cl(10 -3 ; 10 -2 ; 10 -1 and 1 mol/l) in a wide ph range (0+14) by hydroxides of Fe(III), Zr, oxides of Fe(III), Ti(IV), Mn(IV) and Sn(IV) is studied. The dependences of sorption value of Au 3+ on ph of medium, composition and concentrations of electrolytes in solution are defined. Calculations on condition of Au 3+ in aqueous solutions are conducted. Optimal conditions of gold concentration (including 198 Au) and its separation from carrier at sorption process are defined as well.

  16. Biodesulfurization of vanadium-bearing titanomagnetite concentrates and pH control of bioleaching solution

    Science.gov (United States)

    Liu, Xiao-rong; Jiang, Sheng-cai; Liu, Yan-jun; Li, Hui; Wang, Hua-jun

    2013-10-01

    Vanadium-bearing titanomagnetite concentrates were desulfurized with Acidithiobacillus ferrooxidans ( A. ferrooxidans). The sulfur content of the concentrates was reduced from 0.69wt% to 0.14wt% after bioleaching for 15 d with a 10% pulp density at 30°C. Maintaining a stable pH value during biodesulfurization was critical because of high acid consumption, resulting from a combination of nonoxidative and oxidative dissolution of pyrrhotite in acid solution. It is discovered that the citric acid-disodium hydrogen phosphate buffer of pH 2.0 can control the solution pH value smoothly in the optimal range of 2.0-3.0 for A. ferrooxidans growth. Using the buffer in the volume fraction range of 5.0%-15.0% stimulates A. ferrooxidans growth and improves the biodesulfurization efficiency. Compared with the buffer-free control case, the maximum increase of biodesulfurization rate is 29.7% using a 10.0vol% buffer. Bioleaching provides an alternative process for desulfurization of vanadium-bearing titanomagnetite ores.

  17. Equilibrium and kinetic models for colloid release under transient solution chemistry conditions.

    Science.gov (United States)

    Bradford, Scott A; Torkzaban, Saeed; Leij, Feike; Simunek, Jiri

    2015-10-01

    We present continuum models to describe colloid release in the subsurface during transient physicochemical conditions. Our modeling approach relates the amount of colloid release to changes in the fraction of the solid surface area that contributes to retention. Equilibrium, kinetic, equilibrium and kinetic, and two-site kinetic models were developed to describe various rates of colloid release. These models were subsequently applied to experimental colloid release datasets to investigate the influence of variations in ionic strength (IS), pH, cation exchange, colloid size, and water velocity on release. Various combinations of equilibrium and/or kinetic release models were needed to describe the experimental data depending on the transient conditions and colloid type. Release of Escherichia coli D21g was promoted by a decrease in solution IS and an increase in pH, similar to expected trends for a reduction in the secondary minimum and nanoscale chemical heterogeneity. The retention and release of 20nm carboxyl modified latex nanoparticles (NPs) were demonstrated to be more sensitive to the presence of Ca(2+) than D21g. Specifically, retention of NPs was greater than D21g in the presence of 2mM CaCl2 solution, and release of NPs only occurred after exchange of Ca(2+) by Na(+) and then a reduction in the solution IS. These findings highlight the limitations of conventional interaction energy calculations to describe colloid retention and release, and point to the need to consider other interactions (e.g., Born, steric, and/or hydration forces) and/or nanoscale heterogeneity. Temporal changes in the water velocity did not have a large influence on the release of D21g for the examined conditions. This insensitivity was likely due to factors that reduce the applied hydrodynamic torque and/or increase the resisting adhesive torque; e.g., macroscopic roughness and grain-grain contacts. Our analysis and models improve our understanding and ability to describe the amounts

  18. Effect of surface chemistry, solution pH, and ionic strength on the removal of herbicides diuron and amitrole from water by an activated carbon fiber.

    Science.gov (United States)

    Fontecha-Cámara, M A; López-Ramón, M V; Alvarez-Merino, M A; Moreno-Castilla, C

    2007-01-30

    A study was conducted on the effects of carbon surface chemistry, solution pH, and ionic strength on the removal of diuron and amitrole from aqueous solutions by adsorption on an as-received and oxidized activated carbon fiber. Results obtained were explained by the surface characteristics of the adsorbents and the characteristics of the herbicide molecules. Under the experimental conditions used, diuron uptake was much higher than that of amitrole, despite its larger molecular dimensions, due to the lesser water solubility, greater hydrophobicity, and larger dipolar moment of diuron compared with amitrole. Uptake variations associated with differences in carbon surface oxidation, solution pH, and ionic strength were explained by corresponding changes in electrostatic, hydrophobic, and van der Waals interactions.

  19. ISFET pH Sensitivity: Counter-Ions Play a Key Role.

    Science.gov (United States)

    Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip

    2017-02-02

    The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.

  20. The effect of pH on the corrosion behavior of intermetallic compounds Ni{sub 3}(Si,Ti) and Ni{sub 3}(Si,Ti) + 2Mo in sodium chloride solutions

    Energy Technology Data Exchange (ETDEWEB)

    Priyotomo, Gadang, E-mail: gada001@lipi.go.id; Nuraini, Lutviasari, E-mail: Lutviasari@gmail.com [Research Center for Metallurgy and Material, Indonesian Institute of Sciences, Kawasan PUSPIPTEK Gd.474, Setu, Tangerang Selatan, Banten 15314 (Indonesia); Kaneno, Yasuyuki, E-mail: kaneno@mtr.osakafu-u.ac.id [Department of Materials Science, Graduate School of Engineering, Osaka Prefecture University, 1-1 Gakuen-cho, Sakai, Osaka 599-8531 (Japan)

    2015-12-29

    The corrosion behavior of the intermetallic compounds, Ni{sub 3}(Si,Ti) (L1{sub 2}: single phase) and Ni{sub 3}(Si,Ti) + 2Mo (L1{sub 2} and (L12 + Ni{sub ss}) mixture region), has been investigated using an immersion test, electrochemical method and surface analytical method (SEM; scanning electron microscope and EDAX: Energy Dispersive X-ray) in 0.5 kmol/m{sup 3} NaCl solutions at various pH. The corrosion behavior of nickel alloy C-276 was studied under the same experimental conditions as a reference. It was found that the uniform attack was observed on Ni{sub 3}(Si,Ti) for the immersion test at lower pH, while the pitting attack was observed on this compound for this test at neutral solution. Furthermore, Ni{sub 3}(Si,Ti)+2Mo had the preferential dissolution of L1{sub 2} compared to (L1{sub 2} + Ni{sub ss}) mixture region at lower pH, while pitting attack occurred in (L1{sub 2} + Ni{sub ss}) mixture region at neutral solution. For both intermetallic compounds, the magnitude of pitting and uniform attack decrease with increasing pH of solutions. From the immersion test and polarization curves, the corrosion resistance of Ni{sub 3}(Si,Ti)+2Mo is lower than that of Ni{sub 3}(Si,Ti), while the nickel alloy C-276 is the highest one at various pH of solutions. On the other hand, in the lower pH of solutions, the corrosion resistance of tested materials decreased significantly compared to those in neutral and higher pH of solutions.

  1. Magnetite synthesis from ferrous iron solution at pH 6.8 in a continuous stirred tank reactor.

    Science.gov (United States)

    Mos, Yvonne M; Zorzano, Karin Bertens; Buisman, Cees J N; Weijma, Jan

    2018-04-01

    Partial oxidation of defined Fe 2+ solutions is a well-known method for magnetite synthesis in batch systems. The partial oxidation method could serve as basis for an iron removal process in drinking water production, yielding magnetite (Fe 3 O 4 ) as a compact and valuable product. As a first step toward such a process, a series of experiments was carried out, in which magnetite was synthesized from an Fe 2+ solution in a 2 L continuous stirred tank reactor (CSTR) at atmospheric pressure and 32 °C. In four experiments, elevating the pH from an initial value of 5.5 or 6.0 to a final value of 6.8, 7.0 or 7.5 caused green rust to form, eventually leading to magnetite. Formation of NH 4 + in the reactor indicated that NO 3 - and subsequently NO 2 - served as the oxidant. However, mass flow analysis revealed an influx of O 2 to the reactor. In a subsequent experiment, magnetite formation was achieved in the absence of added nitrate. In another experiment, seeding with magnetite particles led to additional magnetite precipitation without the need for a pH elevation step. Our results show, for the first time, that continuous magnetite formation from an Fe 2+ solution is possible under mild conditions, without the need for extensive addition of chemicals.

  2. Effect of pH on corrosion behavior of CuCrZr in solution without and with NaCl

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, C.T.; Wong, P.K. [Department of Electromechanical Engineering, University of Macau (China); Man, H.C. [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong); Cheng, F.T., E-mail: apaftche@polyu.edu.h [Department of Applied Physics, Hong Kong Polytechnic University (Hong Kong)

    2009-10-01

    CuCrZr is a high copper alloy widely used as electrical and thermal conducting material, especially in heat exchangers in nuclear reactors. In this respect, the physical and fatigue properties of CuCrZr have been extensively studied. The electrochemical behavior of CuCrZr, on the other hand, has not been adequately investigated. In the present study, the effect of pH on the corrosion behavior of CuCrZr in aqueous solutions without and with chloride (0.6 M NaCl) was studied. The pH of the solutions is found to exert significant influence on the corrosion behavior of CuCrZr. In acidic solutions without chloride, the corrosion of CuCrZr is ascribed to active dissolution with soluble products. In neutral and alkaline solutions without NaCl, the presence of oxides on the surface of CuCrZr leads to a noble shift in corrosion potential and passivation results in increased corrosion resistance. In chloride solutions at various pH values, the chloride ions influence the formation of the surface layers and the anodic dissolution process during polarization. At high pH, CuCrZr shows significant passivity and high corrosion resistance due to the growth of Cu{sub 2}O/Cu(OH) film which hinders further dissolution whereas at low pH the corrosion resistance is lowered due to active dissolution of Cu.

  3. Effect of pH on corrosion behavior of CuCrZr in solution without and with NaCl

    International Nuclear Information System (INIS)

    Kwok, C.T.; Wong, P.K.; Man, H.C.; Cheng, F.T.

    2009-01-01

    CuCrZr is a high copper alloy widely used as electrical and thermal conducting material, especially in heat exchangers in nuclear reactors. In this respect, the physical and fatigue properties of CuCrZr have been extensively studied. The electrochemical behavior of CuCrZr, on the other hand, has not been adequately investigated. In the present study, the effect of pH on the corrosion behavior of CuCrZr in aqueous solutions without and with chloride (0.6 M NaCl) was studied. The pH of the solutions is found to exert significant influence on the corrosion behavior of CuCrZr. In acidic solutions without chloride, the corrosion of CuCrZr is ascribed to active dissolution with soluble products. In neutral and alkaline solutions without NaCl, the presence of oxides on the surface of CuCrZr leads to a noble shift in corrosion potential and passivation results in increased corrosion resistance. In chloride solutions at various pH values, the chloride ions influence the formation of the surface layers and the anodic dissolution process during polarization. At high pH, CuCrZr shows significant passivity and high corrosion resistance due to the growth of Cu 2 O/Cu(OH) film which hinders further dissolution whereas at low pH the corrosion resistance is lowered due to active dissolution of Cu.

  4. Calorimetric and diffractometric evidence for the sequential crystallization of buffer components and the consequential pH swing in frozen solutions.

    Science.gov (United States)

    Sundaramurthi, Prakash; Shalaev, Evgenyi; Suryanarayanan, Raj

    2010-04-15

    Sequential crystallization of succinate buffer components in the frozen solution has been studied by differential scanning calorimetry and X-ray diffractometry (both laboratory and synchrotron sources). The consequential pH shifts were monitored using a low-temperature electrode. When a solution buffered to pH pK(a)(2), the freeze-concentrate pH first decreased and then increased due to the sequential crystallization of the basic (disodium succinate) followed by the acidic (monosodium succinate and succinic acid) buffer components. XRD provided direct evidence of the crystallization events in the frozen buffer solutions, including the formation of disodium succinate hexahydrate [Na(2)(CH(2)COO)(2).6H(2)O]. When the frozen solution was warmed in a differential scanning calorimeter, multiple endotherms attributable to the melting of buffer components and ice were observed. When the frozen solutions were dried under reduced pressure, ice sublimation was followed by dehydration of the crystalline hexahydrate to a poorly crystalline anhydrate. However, crystalline succinic acid and monosodium succinate were retained in the final lyophiles. The pH and the buffer salt concentration of the prelyo solution influenced the crystalline salt content in the final lyophile. The direction and magnitude of the pH shift in the frozen solution depended on both the initial pH and the buffer concentration. In light of the pH-sensitive nature of a significant fraction of pharmaceuticals (especially proteins), extreme care is needed in both the buffer selection and its concentration.

  5. Effects of solution P H on the adsorption of aromatic compounds from aqueous solutions by activated carbon

    International Nuclear Information System (INIS)

    Nouri, S.; Haghseresht, F.; Lu, M.

    2002-01-01

    Absorption of p-Cresol, Benzoic acid and Nitro Benzene by activated carbon from dilute aqueous solutions was carried out under controlled ph conditions at 310 k. In acidic conditions, well below the pK a of all solutes, it was observed that the adsorbate solubility and the electron density of its aromatic ring were the influencing factors on the extent of the adsorption by affecting the extent of London dispersion forces. In higher solution ph conditions, on the other hand, it was found that the electrostatic forces played a significant role on the extent of adsorption. The Effect of ph must be considered from its combined effects on the carbon surface and on the solute molecules. It was found that the uptake of the molecular forms of the aromatic solutes was dependent on the substituents of the aromatic ring. Adsorption of the solutes in higher P H values was found to be dependent on the concentration of anionic form of the solutes. All isotherms were fitted into Freundlich Isotherm Equations

  6. Unusual Salt and pH Induced Changes in Polyethylenimine Solutions.

    Directory of Open Access Journals (Sweden)

    Kimberly A Curtis

    Full Text Available Linear PEI is a cationic polymer commonly used for complexing DNA into nanoparticles for cell-transfection and gene-therapy applications. The polymer has closely-spaced amines with weak-base protonation capacity, and a hydrophobic backbone that is kept unaggregated by intra-chain repulsion. As a result, in solution PEI exhibits multiple buffering mechanisms, and polyelectrolyte states that shift between aggregated and free forms. We studied the interplay between the aggregation and protonation behavior of 2.5 kDa linear PEI by pH probing, vapor pressure osmometry, dynamic light scattering, and ninhydrin assay. Our results indicate that: At neutral pH, the PEI chains are associated and the addition of NaCl initially reduces and then increases the extent of association.The aggregate form is uncollapsed and co-exists with the free chains.PEI buffering occurs due to continuous or discontinuous charging between stalled states.Ninhydrin assay tracks the number of unprotonated amines in PEI.The size of PEI-DNA complexes is not significantly affected by the free vs. aggregated state of the PEI polymer. Despite its simple chemical structure, linear PEI displays intricate solution dynamics, which can be harnessed for environment-sensitive biomaterials and for overcoming current challenges with DNA delivery.

  7. Low-temperature solution processing of palladium/palladium oxide films and their pH sensing performance.

    Science.gov (United States)

    Qin, Yiheng; Alam, Arif U; Pan, Si; Howlader, Matiar M R; Ghosh, Raja; Selvaganapathy, P Ravi; Wu, Yiliang; Deen, M Jamal

    2016-01-01

    Highly sensitive, easy-to-fabricate, and low-cost pH sensors with small dimensions are required to monitor human bodily fluids, drinking water quality and chemical/biological processes. In this study, a low-temperature, solution-based process is developed to prepare palladium/palladium oxide (Pd/PdO) thin films for pH sensing. A precursor solution for Pd is spin coated onto pre-cleaned glass substrates and annealed at low temperature to generate Pd and PdO. The percentages of PdO at the surface and in the bulk of the electrodes are correlated to their sensing performance, which was studied by using the X-ray photoelectron spectroscope. Large amounts of PdO introduced by prolonged annealing improve the electrode's sensitivity and long-term stability. Atomic force microscopy study showed that the low-temperature annealing results in a smooth electrode surface, which contributes to a fast response. Nano-voids at the electrode surfaces were observed by scanning electron microscope, indicating a reason for the long-term degradation of the pH sensitivity. Using the optimized annealing parameters of 200°C for 48 h, a linear pH response with sensitivity of 64.71±0.56 mV/pH is obtained for pH between 2 and 12. These electrodes show a response time shorter than 18 s, hysteresis less than 8 mV and stability over 60 days. High reproducibility in the sensing performance is achieved. This low-temperature solution-processed sensing electrode shows the potential for the development of pH sensing systems on flexible substrates over a large area at low cost without using vacuum equipment. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Intracellular pH in rat pancreatic ducts

    DEFF Research Database (Denmark)

    Novak, I; Hug, M; Greger, R

    1997-01-01

    In order to study the mechanism of H+ and HCO3- transport in a HCO3- secreting epithelium, pancreatic ducts, we have measured the intracellular pH (pHi) in this tissue using the pH sensitive probe BCECF. We found that exposures of ducts to solutions containing acetate/acetic acid or NH4+/NH3...... buffers (20 mmol/l) led to pHi changes in accordance with entry of lipid-soluble forms of the buffers, followed by back-regulation of pHi by duct cells. In another type of experiment, changes in extracellular pH of solutions containing HEPES or HCO3-/CO2 buffers led to significant changes in pHi that did....... Under some conditions, these exchangers can be invoked to regulate cell pH....

  9. Effect of pH and chloride on the micro-mechanism of pitting corrosion for high strength pipeline steel in aerated NaCl solutions

    International Nuclear Information System (INIS)

    Wang, Yafei; Cheng, Guangxu; Wu, Wei; Qiao, Qiao; Li, Yun; Li, Xiufeng

    2015-01-01

    Highlights: • Pitting behavior of X80 steel in aerated NaCl solutions is studied systematically. • Unique large pit morphology is observed in neutral/acidic NaCl solutions. • In low pH solutions, pit will propagate in the horizontal direction, leading to the shallow shape of pitting morphology; in high pH solutions, the pit sizes are much smaller. • Film growth, which is dependent on the pH and chloride concentration, has great influence on the cathodic reaction by affecting oxygen diffusion process. - Abstract: The pitting corrosion mechanism of high strength pipeline steel in aerated NaCl solutions with different pH and chloride content was investigated, using potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and scanning electron microscope (SEM). The pitting behavior in alkaline solutions was found to be significantly different from that in neutral and acidic solutions. Electrochemical results and SEM images indicate that the product film formed on the steel surface results in different corrosion behavior in an alkaline solution. SEM images show that pH and chloride concentration in the bulk solution have a great influence on the pitting morphology. Unique large pit morphology due to corrosion in neutral/acidic solutions with 0.05 mol/L NaCl was observed. The relationship between solution pH and the effect of chloride concentration is also discussed

  10. Gammaradiation effect on spectral properties of oxyhemoglobin solutions of different pH in the presence of serotonin

    International Nuclear Information System (INIS)

    Artyukhov, V.G.

    1979-01-01

    Changes in spectral properties of oxyhemoglobin solutions (pH 3 to 12) of mice exposed to gammaradiation (6000R) in the presence of serotonin have been studied. It was established that serotonin (5x10 -5 M) exerts a radioprotective effect in respect of oxyhemoglobin solutions of pH 5 to 9. Serotonin fails to protect protein in the presence of catalase (1x10 -6 M). It is stated that the process of formation of hydrogen peroxide/serotonin complex appreciably contributes to the protective action of the radioprotective agent in respect of gammairradiated oxyhemoglobin solutions

  11. Gravity-driven pH adjustment for site-specific protein pKa measurement by solution-state NMR

    Science.gov (United States)

    Li, Wei

    2017-12-01

    To automate pH adjustment in site-specific protein pKa measurement by solution-state NMR, I present a funnel with two caps for the standard 5 mm NMR tube. The novelty of this simple-to-build and inexpensive apparatus is that it allows automatic gravity-driven pH adjustment within the magnet, and consequently results in a fully automated NMR-monitored pH titration without any hardware modification on the NMR spectrometer.

  12. Effects of pH on the stability of cyanidin and cyanidin 3-O-β-glucopyranoside in aqueous solution

    Directory of Open Access Journals (Sweden)

    Rakić Violeta P.

    2015-01-01

    Full Text Available The colour variation, colour intensity and stability at various pH values (2.0, 4.0, 7.0 and 9.0 of cyanidin 3-O-β-glucopyranoside (Cy3Glc and its aglycone cyanidin was investigated during a period of 8 hours storage at 25ºC. Our data showed that pH of aqueous solution had impact on spectroscopic profile of cyanidin and Cy3Glc. Beginning with the most acidic solutions, increasing the pH induce bathochromic shifts of absorbance maximum in the visible range for all examined pH values (with the exception pH 4.0 for cyanidin, while the presence of the 3-glucosidic substitution induce hypsochromic shift. Compared to cyanidin, Cy3Glc has higher colour intensity and higher stability in the whole pH range, except at pH 7.0. The 3-glucosidic substitution influences on the colour intensity of Cy3Glc in the alkaline region. After 8-hour incubation of Cy3Glc and cyanidin at pH 2.0 and 25 ºC, 99% of Cy3Glc and only 27% of cyanidin remained unchanged.

  13. Effect of pH Changes on Antioxidant Capacity and the Content of Betalain Pigments During the Heating of a Solution of Red Beet Betalains

    Directory of Open Access Journals (Sweden)

    Mikołajczyk-Bator Katarzyna

    2017-06-01

    Full Text Available Red beets and their products are mainly consumed after processing. In this study, the effect of pH on changes in antioxidant capacity (AC and the content of betalain pigments were analysed during the heating of a betalain preparation solution. With pH ranging from 4 to 9 during the heat-treatment, the content of red pigments decreased depending on the pH level of the sample. The losses of red pigments in the investigated betalain preparation solution increased along with rising pH levels of the heated solution. The greatest losses were recorded at pH of 9.0. An opposite correlation was observed for yellow pigments. The content of yellow pigments in the heated betalain preparation solution was increasing along with increasing pH. The most pronounced increase in the content of yellow pigments was found at pH of 6.5 and 7.0. At the same time, the heated betalain preparation solution was shown to exhibit a higher antioxidant capacity at pH of 6.0 (14.9 μmol Trolox/mL than at pH of 4.0 (12.6 μmol Trolox/mL. It was observed that the increase in the antioxidant capacity in heated betalain preparation solutions with pH in the 6.0–6.5 range occurred as a result of increased concentrations of neobetanin, assessed by HPLC, within the pH range from 5.0 to 6.5.

  14. Streptococcus oligofermentans Inhibits Streptococcus mutans in Biofilms at Both Neutral pH and Cariogenic Conditions.

    Science.gov (United States)

    Bao, Xudong; de Soet, Johannes Jacob; Tong, Huichun; Gao, Xuejun; He, Libang; van Loveren, Cor; Deng, Dong Mei

    2015-01-01

    Homeostasis of oral microbiota can be maintained through microbial interactions. Previous studies showed that Streptococcus oligofermentans, a non-mutans streptococci frequently isolated from caries-free subjects, inhibited the cariogenic Streptococcus mutans by the production of hydrogen peroxide (HP). Since pH is a critical factor in caries formation, we aimed to study the influence of pH on the competition between S. oligofermentans and S. mutans in biofilms. To this end, S. mutans and S. oligofermentans were inoculated alone or mixed at 1:1 ratio in buffered biofilm medium in a 96-well active attachment model. The single- and dual-species biofilms were grown under either constantly neutral pH or pH-cycling conditions. The latter includes two cycles of 8 h neutral pH and 16 h pH 5.5, used to mimic cariogenic condition. The 48 h biofilms were analysed for the viable cell counts, lactate and HP production. The last two measurements were carried out after incubating the 48 h biofilms in buffers supplemented with 1% glucose (pH 7.0) for 4 h. The results showed that S. oligofermentans inhibited the growth of S. mutans in dual-species biofilms under both tested pH conditions. The lactic acid production of dual-species biofilms was significantly lower than that of single-species S. mutans biofilms. Moreover, dual-species and single-species S. oligofermentans biofilms grown under pH-cycling conditions (with a 16 h low pH period) produced a significantly higher amount of HP than those grown under constantly neutral pH. In conclusion, S. oligofermentans inhibited S. mutans in biofilms not only under neutral pH, but also under pH-cycling conditions, likely through HP production. S. oligofermentans may be a compelling probiotic candidate against caries.

  15. Effect of pH Value on the Electrochemical and Stress Corrosion Cracking Behavior of X70 Pipeline Steel in the Dilute Bicarbonate Solutions

    Science.gov (United States)

    Cui, Z. Y.; Liu, Z. Y.; Wang, L. W.; Ma, H. C.; Du, C. W.; Li, X. G.; Wang, X.

    2015-11-01

    In this work, effects of pH value on the electrochemical and stress corrosion cracking (SCC) behavior of X70 pipeline steel in the dilute bicarbonate solutions were investigated using electrochemical measurements, slow strain rate tensile tests and surface analysis techniques. Decrease of the solution pH from 6.8 to 6.0 promotes the anodic dissolution and cathodic reduction simultaneously. Further decrease of the pH value mainly accelerates the cathodic reduction of X70 pipeline steel. As a result, when the solution pH decreases form 6.8 to 5.5, SCC susceptibility decreases because of the enhancement of the anodic dissolution. When the solution pH decreases from 5.5 to 4.0, SCC susceptibility increases gradually because of the acceleration of cathodic reactions.

  16. Insulin at pH 2: structural analysis of the conditions promoting insulin fibre formation.

    Science.gov (United States)

    Whittingham, Jean L; Scott, David J; Chance, Karen; Wilson, Ashley; Finch, John; Brange, Jens; Guy Dodson, G

    2002-04-26

    When insulin solutions are subjected to acid, heat and agitation, the normal pattern of insulin assembly (dimers-->tetramers-->hexamers) is disrupted; the molecule undergoes conformational changes allowing it to follow an alternative aggregation pathway (via a monomeric species) leading to the formation of insoluble amyloid fibres. To investigate the effect of acid pH on the conformation and aggregation state of the protein, the crystal structure of human insulin at pH 2.1 has been determined to 1.6 A resolution. The structure reveals that the native fold is maintained at low pH, and that the molecule is still capable of forming dimers similar to those found in hexameric insulin structures at higher pH. Sulphate ions are incorporated into the molecule and the crystal lattice where they neutralise positive charges on the protein, stabilising its structure and facilitating crystallisation. The sulphate interactions are associated with local deformations in the protein, which may indicate that the structure is more plastic at low pH. Transmission electron microscopy analysis of insulin fibres reveals that the appearance of the fibres is greatly influenced by the type of acid employed. Sulphuric acid produces distinctive highly bunched, truncated fibres, suggesting that the sulphate ions have a sophisticated role to play in fibre formation, rather as they do in the crystal structure. Analytical ultracentrifugation studies show that in the absence of heating, insulin is predominantly dimeric in mineral acids, whereas in acetic acid the equilibrium is shifted towards the monomer. Hence, the effect of acid on the aggregation state of insulin is also complex. These results suggest that acid conditions increase the susceptibility of the molecule to conformational change and dissociation, and enhance the rate of fibrillation by providing a charged environment in which the attractive forces between the protein molecules is increased. (c) 2002 Elsevier Science Ltd.

  17. Revealing the Dimeric Crystal and Solution Structure of β-Lactoglobulin at pH 4 and Its pH and Salt Dependent Monomer–Dimer Equilibrium

    DEFF Research Database (Denmark)

    Khan, Sanaullah; Ipsen, Richard; Almdal, Kristoffer

    2018-01-01

    The dimeric structure of bovine β-lactoglobulin A (BLGA) at pH 4.0 was solved to 2.0 Å resolution. Fitting the BLGA pH 4.0 structure to SAXS data at low ionic strength (goodness of fit R-factor = 3.6%) verified the dimeric state in solution. Analysis of the monomer–dimer equilibrium at varying pH...... and ionic strength by SAXS and scattering modeling showed that BLGA is dimeric at pH 3.0 and 4.0, shifting toward a monomer at pH 2.2, 2.6, and 7.0 yielding monomer/dimer ratios of 80/20%, 50/50%, and 25/75%, respectively. BLGA remained a dimer at pH 3.0 and 4.0 in 50–150 mM NaCl, whereas the electrostatic...... shielding raised the dimer content at pH 2.2, 2.6, and 7.0, i.e., below and above the pI. Overall, the findings provide new insights into the molecular characteristics of BLGA relevant for dairy product formulations and for various biotechnological and pharmaceutical applications....

  18. pH Sensing Properties of Flexible, Bias-Free Graphene Microelectrodes in Complex Fluids: From Phosphate Buffer Solution to Human Serum.

    Science.gov (United States)

    Ping, Jinglei; Blum, Jacquelyn E; Vishnubhotla, Ramya; Vrudhula, Amey; Naylor, Carl H; Gao, Zhaoli; Saven, Jeffery G; Johnson, Alan T Charlie

    2017-08-01

    Advances in techniques for monitoring pH in complex fluids can have a significant impact on analytical and biomedical applications. This study develops flexible graphene microelectrodes (GEs) for rapid (pH of complex biofluids by measuring real-time Faradaic charge transfer between the GE and a solution at zero electrical bias. For an idealized sample of phosphate buffer solution (PBS), the Faradaic current is varied monotonically and systematically with the pH, with a resolution of ≈0.2 pH unit. The current-pH dependence is well described by a hybrid analytical-computational model, where the electric double layer derives from an intrinsic, pH-independent (positive) charge associated with the graphene-water interface and ionizable (negative) charged groups. For ferritin solution, the relative Faradaic current, defined as the difference between the measured current response and a baseline response due to PBS, shows a strong signal associated with ferritin disassembly and the release of ferric ions at pH ≈2.0. For samples of human serum, the Faradaic current shows a reproducible rapid (pH. By combining the Faradaic current and real-time current variation, the methodology is potentially suitable for use to detect tumor-induced changes in extracellular pH. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Effect of Nutrition Solution pH and Electrical Conductivity on Fusarium Wilt on Strawberry Plants in Hydroponic Culture

    Directory of Open Access Journals (Sweden)

    Myeong Hyeon Nam

    2018-03-01

    Full Text Available Fusarium wilt on strawberry plants caused by Fusarium oxysporum f. sp. fragariae (Fof is a major disease in Korea. The prevalence of this disease is increasing, especially in hydroponic cultivation in strawberry field. This study assessed the effect of nutrition solution pH and electrical conductivity (EC on Fusarium wilt in vitro and in field trials. pH levels of 5.0, 5.5, 6.0, 6.5, 7.0, and 7.5 were assayed in vitro and in field trials. EC levels at 0, 0.5, 0.8, 1.0, and 1.5 dS∙m⁻¹ were assayed in field trials. Mycelial growth of Fof increased with increasing pH and was highest at 25°C pH 7 and lowest at 20°C, pH 5.0 in vitro. The incidence of Fusarium wilt was lowest in the pH 6.5 treatment and highest in the pH 5 treatment in field trials. At higher pH levels, the EC decreased in the drain solution and the potassium content of strawberry leaves increased. In the EC assay, the severity of Fusarium wilt and nitrogen content of leaves increased as the EC increased. These results indicate that Fusarium wilt is related to pH and EC in hydroponic culture of strawberry plants.

  20. Development of a microprocessor-controlled coulometric system for stable ph control

    NARCIS (Netherlands)

    Bergveld, Piet; van der Schoot, B.H.

    1983-01-01

    The coulometric pH control system utilizes a programmable coulostat for controlling the pH of a certain volume of unbuffered solution. Based on theoretical considerations, conditions are established which guarantee stable operation with maximum suppression of disturbances from the dissolution of

  1. Influence of pH on extracellular matrix preservation during lung decellularization.

    Science.gov (United States)

    Tsuchiya, Tomoshi; Balestrini, Jenna L; Mendez, Julio; Calle, Elizabeth A; Zhao, Liping; Niklason, Laura E

    2014-12-01

    The creation of decellularized organs for use in regenerative medicine requires the preservation of the organ extracellular matrix (ECM) as a means to provide critical cues for differentiation and migration of cells that are seeded onto the organ scaffold. The purpose of this study was to assess the influence of varying pH levels on the preservation of key ECM components during the decellularization of rat lungs. Herein, we show that the pH of the 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS)-based decellularization solution influences ECM retention, cell removal, and also the potential for host response upon implantation of acellular lung tissue. The preservation of ECM components, including elastin, fibronectin, and laminin, were better retained in the lower pH conditions that were tested (pH ranges tested: 8, 10, 12); glycosaminoglycans were preserved to a higher extent in the lower pH groups as well. The DNA content following decellularization of the rat lung was inversely correlated with the pH of the decellularization solution. Despite detectible levels of cyotoskeletal proteins and significant residual DNA, tissues decellularized at pH 8 demonstrated the greatest tissue architecture maintenance and the least induction of host response of all acellular conditions. These results highlight the effect of pH on the results obtained by organ decellularization and suggest that altering the pH of the solutions used for decellularization may influence the ability of cells to properly differentiate and home to appropriate locations within the scaffold, based on the preservation of key ECM components and implantation results.

  2. Flux Balance Analysis of Escherichia coli under Temperature and pH Stress Conditions

    KAUST Repository

    Xu, Xiaopeng

    2015-01-01

    important roles in specific conditions and are essential genes under those conditions. E. coli is a model organism, which is widely used. It can adapt to many stress conditions, including temperature, pH, osmotic, antibiotic, etc. Underlying mechanisms

  3. New analytical methodology for analysing S(IV) species at low pH solutions by one stage titration method (bichromatometry) with a clear colour change. Could potentially replace the state-of-art-method iodometry at low pH analysis due higher accuracy.

    Science.gov (United States)

    Santasalo-Aarnio, Annukka; Galfi, Istvan; Virtanen, Jorma; Gasik, Michael M

    2017-01-01

    A new, faster and more reliable analytical methodology for S(IV) species analysis at low pH solutions by bichromatometry is proposed. For decades the state of the art methodology has been iodometry that is still well justified method for neutral solutions, thus at low pH media possess various side reactions increasing inaccuracy. In contrast, the new methodology has no side reactions at low pH media, requires only one titration step and provides a clear color change if S(IV) species are present in the solution. The method is validated using model solutions with known concentrations and applied to analyses of gaseous SO2 from purged solution in low pH media samples. The results indicate that bichromatometry can accurately analyze SO2 from liquid samples having pH even below 0 relevant to metallurgical industrial processes.

  4. Effect of pH on the corrosion behaviour of SUS321 in the ammonia aqueous solution

    International Nuclear Information System (INIS)

    Park, Sang Yoon; Jeong, Y. H.; Baek, J. H.; Choi, B. K.; Lee, M. H.; Choi, B. S.; Yoon, J. H.; Lee, D. J.

    2003-02-01

    The corrosion characteristics of SUS321 for pressure vessel of SMART in pure water, ammonia aqueous solutions of pH 8.5 ∼ 11.5 at 300 .deg. C were evaluated by using static autoclaves. SUS321 specimen in the high temperature ammonia aqueous solution has weight gain or loss by the 4 reactions. And it depends on the refreshing period of the aqueous solution. So additional experiments by recirculating loop system were required to evaluate the corrosion behaviour of SUS321 in the ammonia aqueous solution

  5. Theoretical study on the interactions between chlordecone hydrate and acidic surface groups of activated carbon under basic pH conditions.

    Science.gov (United States)

    Melchor-Rodríguez, Kenia; Gamboa-Carballo, Juan José; Ferino-Pérez, Anthuan; Passé-Coutrin, Nady; Gaspard, Sarra; Jáuregui-Haza, Ulises Javier

    2018-05-01

    A theoretical study of the influence of acidic surface groups (SG) of activated carbon (AC) on chlordecone hydrate (CLDh) adsorption is presented, in order to help understanding the adsorption process under basic pH conditions. A seven rings aromatic system (coronene) with a functional group in the edge was used as a simplified model of AC to evaluate the influence of SG in the course of adsorption from aqueous solution at basic pH conditions. Two SG were modeled in their deprotonated form: carboxyl and hydroxyl (COO - and O - ), interacting with CLDh. In order to model the solvation process, all systems under study were calculated with up to three water molecules. Multiple Minima Hypersurface (MMH) methodology was employed to study the interactions of CLDh with SG on AC using PM7 semiempirical Hamiltonian, to explore the potential energy surfaces of the systems and evaluate their thermodynamic association energies. The re-optimization of representative structures obtained from MMH was done using M06-2X Density Functional Theory. The Quantum Theory of Atoms in Molecules (QTAIM) was used to characterize the interaction types. As result, the association of CLDh with acidic SG at basic pH conditions preferentially occurs between the two alcohol groups of CLDh with COO - and O - groups and by dispersive interactions of chlorine atoms of CLDh with the graphitic surface. On the other hand, the presence of covalent interactions between the negatively charged oxygen of SG and one hydrogen atom of CLDh alcohol groups (O - ⋯HO interactions) without water molecules, was confirmed by QTAIM study. It can be concluded that the interactions of CLDh with acidic SG of AC under basic pH conditions confirms the physical mechanisms of adsorption process. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Hemoglobin bioconjugates with surface-protected gold nanoparticles in aqueous media: The stability depends on solution pH and protein properties.

    Science.gov (United States)

    Del Caño, Rafael; Mateus, Lucia; Sánchez-Obrero, Guadalupe; Sevilla, José Manuel; Madueño, Rafael; Blázquez, Manuel; Pineda, Teresa

    2017-11-01

    The identification of the factors that dictate the formation and physicochemical properties of protein-nanomaterial bioconjugates are important to understand their behavior in biological systems. The present work deals with the formation and characterization of bioconjugates made of the protein hemoglobin (Hb) and gold nanoparticles (AuNP) capped with three different molecular layers (citrate anions (c), 6-mercaptopurine (MP) and ω-mercaptoundecanoic acid (MUA)). The main focus is on the behavior of the bioconjugates in aqueous buffered solutions in a wide pH range. The stability of the bioconjugates have been studied by UV-visible spectroscopy by following the changes in the localized surface resonance plasmon band (LSRP), Dynamic light scattering (DLS) and zeta-potential pH titrations. It has been found that they are stable in neutral and alkaline solutions and, at pH lower than the protein isoelectric point, aggregation takes place. Although the surface chemical properties of the AuNPs confer different properties in respect to colloidal stability, once the bioconjugates are formed their properties are dictated by the Hb protein corona. The protein secondary structure, as analyzed by Attenuated total reflectance infrared (ATR-IR) spectroscopy, seems to be maintained under the conditions of colloidal stability but some small changes in protein conformation take place when the bioconjugates aggregate. These findings highlight the importance to keep the protein structure upon interaction with nanomaterials to drive the stability of the bioconjugates. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Geochemical Data for Upper Mineral Creek, Colorado, Under Existing Ambient Conditions and During an Experimental pH Modification, August 2005

    Science.gov (United States)

    Runkel, Robert L.; Kimball, Briant A.; Steiger, Judy I.; Walton-Day, Katherine

    2009-01-01

    Mineral Creek, an acid mine drainage stream in south-western Colorado, was the subject of a water-quality study that employed a paired synoptic approach. Under the paired synoptic approach, two synoptic sampling campaigns were conducted on the same study reach. The initial synoptic campaign, conducted August 22, 2005, documented stream-water quality under existing ambient conditions. A second synoptic campaign, conducted August 24, 2005, documented stream-water quality during a pH-modification experiment that elevated the pH of Mineral Creek. The experimental pH modification was designed to determine the potential reductions in dissolved constituent concentrations that would result from the implementation of an active treatment system for acid mine drainage. During both synoptic sampling campaigns, a solution containing lithium bromide was injected continuously to allow for the calculation of streamflow using the tracer-dilution method. Synoptic water-quality samples were collected from 30 stream sites and 11 inflow locations along the 2-kilometer study reach. Data from the study provide spatial profiles of pH, concentration, and streamflow under both existing and experimentally-altered conditions. This report presents the data obtained August 21-24, 2005, as well as the methods used for sample collection and data analysis.

  8. Physico-chemical changes of ZnO nanoparticles with different size and surface chemistry under physiological pH conditions.

    Science.gov (United States)

    Gwak, Gyeong-Hyeon; Lee, Won-Jae; Paek, Seung-Min; Oh, Jae-Min

    2015-03-01

    We studied the physico-chemical properties of ZnO nanoparticles under physiological pH conditions (gastric, intestinal and plasma) as functions of their size (20 and 70 nm) and surface chemistry (pristine, L-serine, or citrate coating). ZnO nanoparticles were dispersed in phosphate buffered saline under physiological pH conditions and aliquots were collected at specific time points (0.5, 1, 4, 10 and 24 h) for further characterization. The pH values of the aqueous ZnO colloids at each condition were in the neutral to slightly basic range and showed different patterns depending on the original size and surface chemistry of the ZnO nanoparticles. The gastric pH condition was found to significantly dissolve ZnO nanoparticles up to 18-30 wt%, while the intestinal or plasma pH conditions resulted in much lower dissolution amounts than expected. Based on the X-ray diffraction patterns and X-ray absorption spectra, we identified partial phase transition of the ZnO nanoparticles from wurtzite to Zn(OH)2 under the intestinal and plasma pH conditions. Using scanning electron microscopy, we verified that the overall particle size and morphology of all ZnO nanoparticles were maintained regardless of the pH. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Biocorrosion properties of antibacterial Ti-10Cu sintered alloy in several simulated biological solutions.

    Science.gov (United States)

    Liu, Cong; Zhang, Erlin

    2015-03-01

    Ti-10Cu sintered alloy has shown strong antibacterial properties against S. aureus and E. coli and good cell biocompatibility, which displays potential application in dental application. The corrosion behaviors of the alloy in five different simulated biological solutions have been investigated by electrochemical technology, surface observation, roughness measurement and immersion test. Five different simulated solutions were chosen to simulate oral condition, oral condition with F(-) ion, human body fluids with different pH values and blood system. It has been shown that Ti-10Cu alloy exhibits high corrosion rate in Saliva pH 3.5 solution and Saliva pH 6.8 + 0.2F solution but low corrosion rate in Hank's, Tyrode's and Saliva pH 6.8 solutions. The corrosion rate of Ti-10Cu alloy was in a order of Hank's, Tyrode's, Saliva pH 6.8, Saliva-pH 3.5 and Saliva pH 6.8 + 0.2F from slow to fast. All results indicated acid and F(-) containing conditions prompt the corrosion reaction of Ti-Cu alloy. It was suggested that the Cu ion release in the biological environments, especially in the acid and F(-) containing condition would lead to high antibacterial properties without any cell toxicity, displaying wide potential application of this alloy.

  10. Analysis of the electric conductivity and pH behaviors in recycled drainage solution of rose cv. Charlotte plants grown in substrate

    Directory of Open Access Journals (Sweden)

    Luis Fernando Yepes V

    2013-12-01

    Full Text Available In open soilless cropping systems contamination from nutrient lixiviation is generated making it necessary to design closed or semi-closed systems, which require the determination of the maximum saline levels in recycling solutions. In this study, the electric conductivity (EC and pH behaviors were analyzed in drainage solution intended for recycling in the crop; in addition, parameters were used to estimate nutrient availability for the plants in a substrate based cropping system. This research project was carried out under greenhouse conditions in the municipality of Mosquera (Colombia. Rose cv. Charlotte grafted on "Natal briar" stocks were used, sown in pots arranged on elevated beds, 15 m in length. This project was carried out using a split-plot design with sub-plots (with the substrate as the main plot and the recycling as the sub-plot, three kinds of substrate and three recycling percentages (0, 50, and 100%, for a total of 27 experimental units. Substrate mixtures based on burned rice husk and coconut fiber were used. Recycling during one harvest cycle of the roses did not show EC and pH values above those that are considered to have a negative impact on production; however, an increasing behavior in the EC and pH values was observed. Likewise, no significant differences between the 50 and 100% recycling were observed, which means 100% recycling can be used, optimizing nutrient use and water conservation

  11. Peroxidase-mediated polymerization of 1-naphthol: impact of solution pH and ionic strength.

    Science.gov (United States)

    Bhandari, Alok; Xu, Fangxiang; Koch, David E; Hunter, Robert P

    2009-01-01

    Peroxidase-mediated oxidation has been proposed as a treatment method for naphthol-contaminated water. However, the impact of solution chemistry on naphthol polymerization and removal has not been documented. This research investigated the impact of pH and ionic strength on peroxidase-mediated removal of 1-naphthol in completely mixed batch reactors. The impact of hydrogen peroxide to 1-naphthol ratio and activity of horseradish peroxidase was also studied. Size exclusion chromatography was used to estimate the molecular weight distribution of oligomeric products, and liquid chromatography/mass spectrometry was used to estimate product structure. Naphthol transformation decreased with ionic strength, and substrate removal was lowest at neutral pHs. Solution pH influenced the size and the composition of the oligomeric products. An equimolar ratio of H(2)O(2):naphthol was sufficient for optimal naphthol removal. Polymerization products included naphthoquinones and oligomers derived from two, three, and four naphthol molecules. Our results illustrate the importance of water chemistry when considering a peroxidase-based approach for treatment of naphthol-contaminated waters.

  12. Effect of Fe, Ni, and Cr on the corrosion behaviour of hyper-eutectic Al-Si automotive alloy under different pH conditions

    Directory of Open Access Journals (Sweden)

    Mohammad Salim Kaiser

    2018-05-01

    Full Text Available Effect of Fe, Ni and Cr on the corrosion behaviour of hyper-eutectic Al-Si automotive alloy was studied. The test of corrosion behaviour at different environmental pH 1, 3, 5, 7, 9, 11 and 13 was performed using conventional gravimetric measurements and complemented by resistivity, optical micrograph, scanning electron microscopy (SEM and X-ray analyser (EDX investigations. The highest corrosion rate was observed at pH 13 followed by pH 1, while in the pH range of 3.0 to 11, there is a high protection of surface due to formation of stable surface oxide film. The highest corrosion rate at pH 13 is due to presence of sodium hydroxide in the solution in which the surface oxide film is soluble. At pH 1, however, high corrosion rate can be attributed to dissolution of Al due to the surface attack by aggressive chloride ions. Presence of Fe, Ni and Cr in hyper-eutectic Al-Si automotive alloy has significant effect on the corrosion rate at both environmental pH values. Resistivity of alloy surfaces initially decreases at pH 1 and pH 13 due to formation of thin films. The SEM images of corroded samples immersed in pH 1 solution clearly show pores due to uniform degradation of the alloy. In pH 13 solution, however, the corrosion layer looks more packed and impermeable.

  13. Contribution of solution pH and buffer capacity to suppress intergranular stress corrosion cracking of sensitized type 304 stainless steel at 95 C

    International Nuclear Information System (INIS)

    Zhang, S.; Shibata, T.; Haruna, T.

    1999-01-01

    Controlling pH of high-temperature water to ∼pH 7 at 300 C by adding lithium hydroxide (LiOH) into the coolant system of a pressurized water reactor (PWR) successfully has been mitigating the corrosion of PWR component materials. The effects of solution pH and buffer capacity on intergranular stress corrosion cracking (IGSCC) of sensitized type 304 stainless steel ([SS] UNS S30400) was examined at 95 C by slow strain rate technique (SSRT) with an in-situ cracking observation system. It was found that an increase in solution pH or buffer capacity increased crack initiation time and decreased mean crack initiation frequency, but exerted almost no effect on crack propagation. This inhibition effect on IGSCC initiation was explained as resulting from a retarding effect of solution pH and buffer capacity on the decrease in pH at crack nuclei caused by the hydrolysis of metal ions dissolved when the passive film was ruptured by strain in SSRT

  14. pH sensing characteristics and biosensing application of solution-gated reduced graphene oxide field-effect transistors.

    Science.gov (United States)

    Sohn, Il-Yung; Kim, Duck-Jin; Jung, Jin-Heak; Yoon, Ok Ja; Thanh, Tien Nguyen; Quang, Trung Tran; Lee, Nae-Eung

    2013-07-15

    Solution-gated reduced graphene oxide field-effect transistors (R-GO FETs) were investigated for pH sensing and biochemical sensing applications. A channel of a networked R-GO film formed by self-assembly was incorporated as a sensing layer into a solution-gated FET structure for pH sensing and the detection of acetylcholine (Ach), which is a neurotransmitter in the nerve system, through enzymatic reactions. The fabricated R-GO FET was sensitive to protons (H(+)) with a pH sensitivity of 29 mV/pH in terms of the shift of the charge neutrality point (CNP), which is attributed to changes in the surface potential caused by the interaction of protons with OH surface functional groups present on the R-GO surface. The R-GO FET immobilized with acetylcholinesterase (AchE) was used to detect Ach in the concentration range of 0.1-10mM by sensing protons generated during the enzymatic reactions. The results indicate that R-GO FETs provide the capability to detect protons, demonstrating their applicability as a biosensing device for enzymatic reactions. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Influence of the pH value of a colloidal gold solution on the absorption spectra of an LSPR-assisted sensor

    International Nuclear Information System (INIS)

    Zhu, Jin; Li, Wenbin; Zhu, Mao; Zhang, Wei; Niu, Wencheng; Liu, Guohua

    2014-01-01

    The localized surface plasmon resonances (LSPRs) of gold particles assembled on a crystal plate are a powerful tool for biological sensors. Here, we prepare gold colloids in different pH solutions. We monitor the effects of the particle radius and particle coverage on the absorption spectra of AT-cut (r-face dihedral angle of about 3°) crystal plates supporting gold nanoparticles. The surface morphologies were monitored on silicon dioxide substrates using ultraviolet and visible (UV-vis) spectroscopy, and atomic force microscopy (AFM). The results showed that the gold particle coverage decreases with increasing pH value of the gold colloid solution. This phenomenon demonstrates that self-assembled gold surfaces were formed via the electrostatic adsorption of gold particles on the positively charged, ionized amino groups on the crystal plates in the acidic solution. The spectrum of gold nanoparticles with different coverage degree on the crystal plates showed that the LSPR properties are highly dependent on pH

  16. Migration characteristics of cobalt-60 through sandy soil in high pH solution

    International Nuclear Information System (INIS)

    Ohnuki, Toshihiko

    1992-01-01

    Migration characteristics of 60 Co through sandy soil in high pH solution has been investigated by both column and batch techniques. The association of 60 Co with the sandy soil and its components were studied by sequential extraction techniques. The concentration profile of 60 Co in the sandy soil column was composed of two exponential curves showing that 60 Co would consist of immobile and mobile fractions. The immobile 60 Co was retained by the sandy soil and was distributed near the top. Though the mobile 60 Co was little sorbed by soil and migrated through the soil column, maximum concentration of 60 Co in the effluents decreased slightly with increasing path length of the soil column. The sequential extraction of 60 Co from the sandy soil and from its components showed that 60 Co was sorbed by both manganese oxide and clay minerals. And manganese oxide is one of the responsible soil components for the observed decrease in the maximum concentration of 60 Co in the effluents. Although the content of manganese oxide in the sandy soil was 0.13%, manganese oxide is the important component to prevent from the migration of 60 Co in the high pH solution. (author)

  17. The electrochemical behaviour of stainless steel AISI 304 in alkaline solutions with different pH in the presence of chlorides

    International Nuclear Information System (INIS)

    Freire, L.; Carmezim, M.J.; Ferreira, M.G.S.; Montemor, M.F.

    2011-01-01

    Highlights: → The passivation and passivation breakdown of AISI 304 in alkaline solutions with different pH was studied. → The electrochemical behaviour and the corrosion resistance in chloride environments were evaluated using d.c. potentiodynamic polarization and electrochemical impedance spectroscopy. → The results were modelled using a hierarchically distributed circuit and revealed a more susceptible surface at pH 9. → The passive film characterization was carried out by SEM and EDS analysis, revealing the existence of MnS inclusions and the increase of Cr/Fe ratio in the attacked areas, preferably the vicinity of those inclusions. - Abstract: Nowadays, stainless steel reinforcements appear as an effective solution to increase the durability of reinforced concrete structures exposed to very aggressive environments. AISI 304 is widely used for this purpose. Although the improved durability of reinforcing AISI 304, when compared to carbon steel, there is a high probability of pitting susceptibility in the presence of chlorides. Thus, the present work aims at studying the passivation and passivation breakdown of AISI 304 in alkaline solutions of different pH (pH from 13 to 9), simulating the interstitial concrete electrolyte. These solutions were contaminated with different concentrations of chloride ions (3% and 10%, as NaCl). The electrochemical behaviour was evaluated by d.c. potentiodynamic polarization and by electrochemical impedance spectroscopy (EIS). The morphological features and the changes observed in the surface composition were evaluated by Scanning Electron Microscopy (SEM) together with EDS chemical analysis. The results evidence that pH plays an important role in the evolution of the film resistance and charge transfer processes. Moreover, the effect is highly dependent upon the chloride content and immersion time.

  18. Impact of Initial pH and Pyrolysis Temperature on the Adsorption of Cr(Ⅵ from Aqueous Solutions on Corn Straw-based Materials

    Directory of Open Access Journals (Sweden)

    WANG Shuai

    2016-09-01

    Full Text Available Batch experiments were performed on Cr(Ⅵ adsorption using four straw-based materials including corn straw and three kinds of biochar pyrolysed at 300 ℃, 450 ℃ and 600 ℃, respectively. The results showed that the Cr(Ⅵ adsorption were significantly affected by initial pH and pyrolysis temperature. The data were described by kinetic and isotherm models, and showed that the adsorption of Cr(Ⅵ was increased with the decrease of initial pH. The removal rates of Cr(Ⅵ were decreased with the increase of the pyrolysis temperature at pH=3 or pH=5. The biochar pyrolysed at 300 ℃ had the best capability of removing Cr(Ⅵ from aqueous solution at pH=1, and the maxi-mum adsorption quantity was 141.24 mg·g-1 approximately. It observed that both the lower initial pH and the lower pyrolysis temperature had positive effects on the removal of Cr(Ⅵ from aqueous solution.

  19. Reaction kinetics of hydrazine neutralization in steam generator wet lay-up solution: Identifying optimal degradation conditions

    International Nuclear Information System (INIS)

    Schildermans, Kim; Lecocq, Raphael; Girasa, Emmanuel

    2012-09-01

    During a nuclear power plant outage, hydrazine is used as an oxygen scavenger in the steam generator lay-up solution. However, due to the carcinogenic effects of hydrazine, more stringent discharge limits are or will be imposed in the environmental permits. Hydrazine discharge could even be prohibited. Consequently, hydrazine alternatives or hydrazine degradation before discharge is needed. This paper presents the laboratory tests performed to characterize the reaction kinetics of hydrazine neutralization using bleach or hydrogen peroxide, catalyzed with either copper sulfate (CuSO 4 ) or potassium permanganate (KMnO 4 ). The tests are performed on two standard steam generator lay-up solutions based on different pH control agents: ammonia or ethanolamine. Different neutralization conditions are tested by varying temperature, oxidant addition, and catalyst concentration, among others, in order to identify the optimal parameters for hydrazine neutralization in a steam generator wet lay-up solution. (authors)

  20. Growth-promoting effects of a seaweed concentrate at various pH and water hardness conditions

    Directory of Open Access Journals (Sweden)

    Georgina D. Arthur

    2013-11-01

    Full Text Available Kelpak® – a liquid seaweed concentrate made from the kelp Ecklonia maxima (Osbeck Papenfuss – is used as a natural biostimulant to promote rooting and improve yield in crops. Plant–soil environmental conditions and the chemistry of water used for irrigation may affect the efficiency of Kelpak. The effect of pH (pH 4.5, 6.5 and 8.5 and water hardness (200 mg/L and 400 mg/L Ca2+ on the growth-promoting ability of Kelpak was assessed using the mungbean rooting bioassay and in a pot trial with Swiss chard. Kelpak promoted rooting in all the treatments in the mungbean bioassay with maximum rooting generally achieved with 20% Kelpak. With 20% Kelpak, the addition of 200 mg/L and 400 mg/L Ca2+ decreased rooting at pH 4.5, increased rooting at pH 6.5 and did not affect rooting at pH 8.5. A similar trend was observed in the pot trial with Swiss chard: leaf and root (fresh weight and pigment content (chl a, chl b and carotenoids improved with the addition of 200 mg/L Ca2+ + 5% Kelpak at pH 6.5 or pH 8.5, while Kelpak was able to partially mask the negative effect of 200 mg/L Ca2+ at pH 4.5. These results suggest that while Kelpak is most effective in neutral pHs, it can be used to promote plant growth in a wide range of pH and water hardness conditions.

  1. Pyrite oxidation at circumneutral pH

    Science.gov (United States)

    Moses, Carl O.; Herman, Janet S.

    1991-02-01

    Previous studies of pyrite oxidation kinetics have concentrated primarily on the reaction at low pH, where Fe(III) has been assumed to be the dominant oxidant. Studies at circumneutral pH, necessitated by effective pH buffering in some pyrite oxidation systems, have often implicitly assumed that the dominant oxidant must be dissolved oxygen (DO), owing to the diminished solubility of Fe(III). In fact, Fe(III)(aq) is an effective pyrite oxidant at circumneutral pH, but the reaction cannot be sustained in the absence of DO. The purpose of this experimental study was to ascertain the relative roles of Fe(III) and DO in pyrite oxidation at circumneutral pH. The rate of pyrite oxidation was first-order with respect to the ratio of surface area to solution volume. Direct determinations of both Fe(II) (aq)> and Fe(III) (aq) demonstrated a dramatic loss of Fe(II) from the solution phase in excess of the loss for which oxidation alone could account. Based on rate data, we have concluded that Fe(II) is adsorbed onto the pyrite surface. Furthermore, Fe(II) is preferred as an adsorbate to Fe(III), which we attribute to both electrostatic and acid-base selectivity. We also found that the rate of pyrite oxidation by either Fe(III) (aq) or DO is reduced in the presence of aqueous Fe(II), which leads us to conclude that, under most natural conditions, neither Fe(III) (aq) nor DO directly attacks the pyrite surface. The present evidence suggests a mechanism for pyrite oxidation that involves adsorbed Fe( II ) giving up electrons to DO and the resulting Fe(III) rapidly accepting electrons from the pyrite. The adsorbed Fe is, thus, cyclically oxidized and reduced, while it acts as a conduit for electrons traveling from pyrite to DO. Oxygen is transferred from the hydration sphere of the adsorbed Fe to pyrite S. The cycle of adsorbed Fe oxidation and reduction and the successive addition of oxygen to pyrite S continues until a stable sulfoxy species dissociates from the surface. Prior

  2. SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS

    Science.gov (United States)

    Tompkins, E.R.

    1959-02-24

    The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.

  3. Transport of titanium dioxide nanoparticles in saturated porous media under various solution chemistry conditions

    International Nuclear Information System (INIS)

    Wang Yu; Gao Bin; Morales, Verónica L.; Tian Yuan; Wu Lei; Gao Jie; Bai Wei; Yang Liuyan

    2012-01-01

    Because of its wide applications, nanosized titanium dioxide may become a potential environmental risk to soil and groundwater system. It is therefore important to improve current understanding of the environmental fate and transport of titanium oxides nanoparticles (TONPs). In this work, the effect of solution chemistry (i.e., pH, ionic strength, and natural organic matter (NOM) concentration) on the deposition and transport of TONPs in saturated porous media was examined in detail. Laboratory columns packed with acid-cleaned quartz sand were used in the experiment as porous media. Transport experiments were conducted with various chemistry combinations, including four ionic strengths, three pH levels, and two NOM concentrations. The results showed that TONP mobility increased with increasing solution pH, but decreased with increasing solution ionic strength. It is also found that the presence of NOM in the system enhanced the mobility of TONPs in the saturated porous media. The Derjaguin–Landau–Verwey–Overbeek (DLVO) theory was used to justify the mobility trends observed in the experimental data. Predictions from the theory agreed excellently with the experimental data.

  4. Calculation of the equilibrium pH in a multiple-buffered aqueous solution based on partitioning of proton buffering: a new predictive formula.

    Science.gov (United States)

    Nguyen, Minhtri K; Kao, Liyo; Kurtz, Ira

    2009-06-01

    Upon the addition of protons to an aqueous solution containing multiple buffers, the final H+ concentration ([H+]) at equilibrium is determined by the partitioning of added H+ among the various buffer components. In the analysis of acid-base chemistry, the Henderson-Hasselbalch equation and the Stewart strong ion formulation can only describe (rather than predict) the equilibrium pH following a proton load since these formulas calculate the equilibrium pH only when the reactant concentrations at equilibrium(1) 1The term "equilibrium" refers to the steady state proton and reactant concentrations when the buffering of excess protons by the various buffers is complete. are already known. In this regard, it is simpler to directly measure the equilibrium pH rather than measure the equilibrium reactant concentrations to calculate the equilibrium pH. As these formulas cannot predict the final equilibrium [H+] following a proton load to a multiple-buffered aqueous solution, we developed a new quantitative approach for predicting the equilibrium [H+] that is based on the preequilibrium(2)2 The term "preequilibrium" refers to the initial proton and reactant concentrations immediately upon addition of protons and before the buffering of excess protons by the various buffers. concentrations of all buffers in an aqueous solution. The mathematical model used to derive our equation is based on proton transfer buffer equilibria without requiring the incorporation of electroneutrality considerations. The model consists of a quartic polynomial equation that is derived based solely on the partitioning of H+ among the various buffer components. We tested the accuracy of the model using aqueous solutions with various buffers and measured the equilibrium pH values following the addition of HCl. Our results confirmed the accuracy of our new equation (r2 = 1; measured pH vs. predicted pH), indicating that it quantitatively accounts for the underlying acid-base phenomenology.

  5. Calculation of the equilibrium pH in a multiple-buffered aqueous solution based on partitioning of proton buffering: a new predictive formula

    Science.gov (United States)

    Nguyen, Minhtri K.; Kao, Liyo; Kurtz, Ira

    2009-01-01

    Upon the addition of protons to an aqueous solution containing multiple buffers, the final H+ concentration ([H+]) at equilibrium is determined by the partitioning of added H+ among the various buffer components. In the analysis of acid-base chemistry, the Henderson-Hasselbalch equation and the Stewart strong ion formulation can only describe (rather than predict) the equilibrium pH following a proton load since these formulas calculate the equilibrium pH only when the reactant concentrations at equilibrium1 1The term “equilibrium” refers to the steady state proton and reactant concentrations when the buffering of excess protons by the various buffers is complete. are already known. In this regard, it is simpler to directly measure the equilibrium pH rather than measure the equilibrium reactant concentrations to calculate the equilibrium pH. As these formulas cannot predict the final equilibrium [H+] following a proton load to a multiple-buffered aqueous solution, we developed a new quantitative approach for predicting the equilibrium [H+] that is based on the preequilibrium22The term “preequilibrium” refers to the initial proton and reactant concentrations immediately upon addition of protons and before the buffering of excess protons by the various buffers. concentrations of all buffers in an aqueous solution. The mathematical model used to derive our equation is based on proton transfer buffer equilibria without requiring the incorporation of electroneutrality considerations. The model consists of a quartic polynomial equation that is derived based solely on the partitioning of H+ among the various buffer components. We tested the accuracy of the model using aqueous solutions with various buffers and measured the equilibrium pH values following the addition of HCl. Our results confirmed the accuracy of our new equation (r2 = 1; measured pH vs. predicted pH), indicating that it quantitatively accounts for the underlying acid-base phenomenology. PMID

  6. The sensitivity of particle pH to NH3: Can high NH3 cause London Fog conditions?

    Science.gov (United States)

    Weber, R. J.; Guo, H.; Nenes, A.

    2017-12-01

    High ammonia emissions from agriculture or other sources have been suggested to elevate ambient particle pH levels to near neutral acidity (pH=7), a condition that promotes rapid SO2 oxidation by NO2 to form aerosol sulfate concentration consistent with "London fog" levels. This mechanism has been used to explain pollution haze events in China. Predicted pH for locations in the US and Europe show fine particles are highly acidic with pH typically less than 2. The results are consistent with measured ammonia and nitric acid gas-particle partitioning, validating predicted pH levels. Using these data sets from representative sites around the world we conduct a thermodynamic analysis of aerosol pH and its sensitivity to ammonia levels. We find that particle pH, regardless of ammonia levels, is always acidic even for the unusually high ammonia levels found in highly polluted Asian cities, Beijing (pH=4.5) and Xi'an (pH=5), locations where sulfate production from NOx is proposed. These results indicate that sulfur dioxide oxidation through a NO2-mediated pathway is not likely in China, nor any other region of the world (e.g., US, Mediterranean) since the fine aerosol is consistently acidic. The mildly acidic conditions would, however, permit rapid oxidation of sulfur dioxide through transition metal chemistry. The limited alkalinity from the carbonate buffer in dust and seasalt can provide the only likely set of conditions where NO2-mediated oxidation of SO2 outcompetes with other well-established pathways.

  7. Synthesis and HNO Donating Properties of the Piloty's Acid Analogue Trifluoromethanesulphonylhydroxamic acid: Evidence for Quantitative Release of HNO at Neutral pH Conditions.

    Science.gov (United States)

    Adas, Sonya K; Bharadwaj, Vinay; Zhou, Yang; Zhang, Jiuhong; Seed, Alexander J; Brasch, Nicola Elizabeth; Sampson, Paul

    2018-03-11

    Trifluoromethanesulphonylhydroxamic acid, CF3SO2NHOH, is shown to release HNO under physiological pH conditions. A two-step synthesis is presented with the first complete characterization of CF3SO2NHOH. This molecule rapidly decomposes in neutral aqueous solution to cleanly release HNO and CF3SO2-, demonstrated using the HNO traps TXPTS and HOCbl, and by 19F NMR spectroscopy. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. EXAFS study influence of pH on microscopic structure of zinc

    International Nuclear Information System (INIS)

    Li Xianliang; Chongqing Entry-Exit Inspection and Quarantine Bureau, Chongqing; Pan Gang; Zhu Mengqiang; Chen Hao; Hu Tiandou; Wu Ziyu; Xie Yaning; Du Yonghua

    2004-01-01

    Microscopic local structures of Zn(II) were studied using extended X-ray absorption fine structure (EXAFS) spectroscopy under different pH conditions. When pH 2+ (aq) was coordinated with six water molecules and the average Zn-O distance was measured to be 2.08 Angstrom, which indicated that hydrated Zn 2+ (aq) ions were in octahedral geometry under acid conditions. Under alkaline conditions, Zn 2+ (aq) was coordinated with four water molecules and the average Zn-O distance was measured to be 1.96 Angstrom, which indicated that hydrated Zn 2+ (aq) ions were in tetrahedral geometry. EXAFS results provided detailed information on the form and microscopic structure of hydrated Zn(II) ions under different pH conditions, which were fundamental for understanding the reactivity of Zn(II) in solutions and at particle-water interfaces. (authors)

  9. Sensitive detection of strong acidic condition by a novel rhodamine-based fluorescent pH chemosensor.

    Science.gov (United States)

    Tan, Jia-Lian; Yang, Ting-Ting; Liu, Yu; Zhang, Xue; Cheng, Shu-Jin; Zuo, Hua; He, Huawei

    2016-05-01

    A novel rhodamine-based fluorescent pH probe responding to extremely low pH values has been synthesized and characterized. This probe showed an excellent photophysical response to pH on the basis that the colorless spirocyclic structure under basic conditions opened to a colored and highly fluorescent form under extreme acidity. The quantitative relationship between fluorescence intensity and pH value (1.75-2.62) was consistent with the equilibrium equation pH = pKa + log[(Imax - I)/(I - Imin)]. This sensitive pH probe was also characterized with good reversibility and no interaction with interfering metal ions, and was successfully applied to image Escherichia coli under strong acidity. Copyright © 2015 John Wiley & Sons, Ltd.

  10. New Insight into the Hydrogen Evolution Reaction under Buffered Near-Neutral pH Conditions: Enthalpy and Entropy of Activation

    KAUST Repository

    Shinagawa, Tatsuya

    2016-10-06

    Electrochemical conversion of thermodynamically stable chemicals of water and carbon dioxide is regarded as a core technology for achieving sustainability in our society. In both cases, the electrochemical hydrogen evolution reaction (HER) is a key reaction, particularly at near-neutral pH. This study addresses the kinetic aspects of the HER in buffered near-neutral pH conditions using a variety of electrode materials (W, Ni, Pt, Au, and Cu) over a wide temperature range (299–346 K). When the overall performance was summarized with respect to the binding energy of the reaction intermediate species, a classic volcano-shaped relationship was obtained. Interestingly, the temperature sensitivity analysis disclosed that smaller activation energies did not always lead to higher performance in 1.5 mol L–1 K-phosphate solution (pH 5.8). Detailed analysis of the temperature- and potential-dependent parameters revealed that smaller activation energies coincided with smaller values of the pre-exponential factor in the Arrhenius’ equation (associated with the entropy of activation). Due to the trade-off relationship of enthalpy–entropy compensation in the current system, the conventional approach of mixing elements of lower and higher binding energies to the intermediate species failed: even though Ni–Cu showed lower apparent activation energy, its activity toward the HER was between that of Ni and Cu due to the lowered entropy of activation. This study demonstrates the unrevealed fundamental aspects of the HER in buffered near-neutral condition, which contributes to the rational development of efficient energy and material conversion systems.

  11. Fate of cadmium at the soil-solution interface: a thermodynamic study as influenced by varying pH at South 24 Parganas, West Bengal, India.

    Science.gov (United States)

    Karak, Tanmoy; Paul, Ranjit Kumar; Das, Sampa; Das, Dilip K; Dutta, Amrit Kumar; Boruah, Romesh K

    2015-11-01

    A study on the sorption kinetics of Cd from soil solution to soils was conducted to assess the persistence of Cd in soil solution as it is related to the leaching, bioavailability, and potential toxicity of Cd. The kinetics of Cd sorption on two non-contaminated alkaline soils from Canning (22° 18' 48.02″ N and 88° 39' 29.0″ E) and Lakshmikantapur (22° 06' 16.61″ N and 88° 19' 08.66″ E) of South 24 Parganas, West Bengal, India, were studied using conventional batch experiment. The variable soil suspension parameters were pH (4.00, 6.00, 8.18, and 9.00), temperatures (308, 318, and 328 K) and Cd concentrations (5-100 mg L(-1)). The average rate coefficient (kavg) and half-life (t1/2) values indicate that the persistence of Cd in soil solution is influenced by both temperature and soil suspension pH. The concentration of Cd in soil solution decreases with increase of temperature; therefore, Cd sorption on the soil-solution interface is an endothermic one. Higher pH decreases the t 1/2 of Cd in soil solution, indicating that higher pH (alkaline) is not a serious concern in Cd toxicity than lower pH (acidic). Based on the energy of activation (Ea) values, Cd sorption in acidic pH (14.76±0.29 to 64.45±4.50 kJ mol(-1)) is a surface control phenomenon and in alkaline pH (9.33±0.09 to 44.60±2.01 kJ mol(-1)) is a diffusion control phenomenon The enthalpy of activation (ΔH∓) values were found to be between 7.28 and 61.73 kJ mol(-1). Additionally, higher positive energy of activation (ΔG∓) values (46.82±2.01 to 94.47±2.36 kJ mol(-1)) suggested that there is an energy barrier for product formation.

  12. Treatment and conditioning of radioactive waste solution by natural clay minerals

    International Nuclear Information System (INIS)

    El-Dessouky, M.I.; El-Massry, E.H.; Khalifa, S.M.; Aly, H.F.

    1999-01-01

    Natural inorganic exchangers. Was used to remove caesium, cobalt and europium using zinc sulfate as coagulant also different clay minerals. These calys include, feldrspare, aswanly, bentionite, hematite, mud, calcite, basalt, magnetite, kaoline sand stone, limonite and sand. The factros affecting the removal process namely PH, particle size, temperature and weight of the clay have been studied. Highest removal for Cs-137, Co-60 and Eu-152 and 154 was achived by asswanly and bentonite. Sand stone is more effective than the other clays. Removal of Cs-137 from low level waste solution is in the order the sequence, aswanly (85.5%)> bentonite (82.2%)> sandstone (65.4%). Solidified cement products have been evaluated to determine optimum conditions of mixing most sludges contained clays by testing mechanical strength and leaching rates of the waste products. The solidified waste forms were found more acceptable for handing, storage and ultimate disposal

  13. Effects of pH and chloride concentration on pitting corrosion of AA6061 aluminum alloy

    International Nuclear Information System (INIS)

    Zaid, B.; Saidi, D.; Benzaid, A.; Hadji, S.

    2008-01-01

    Effects of pH solution and chloride (Cl - ) ion concentration on the corrosion behaviour of alloy AA6061 immersed in aqueous solutions of NaCl have been investigated using measurements of weight loss, potentiodynamic polarisation, linear polarisation, cyclic polarisation experiment combined with open circuit potential transient technique and optical or scanning electron microscopy. The corrosion behaviour of the AA6061 aluminum alloy was found to be dependant on the pH and chloride concentration [NaCl] of solution. In acidic or slightly neutral solutions, general and pitting corrosion occurred simultaneously. In contrast, exposure to alkaline solutions results in general corrosion. Experience revealed that the alloy AA6061 was susceptible to pitting corrosion in all chloride solution of concentration ranging between 0.003 wt% and 5.5 wt% NaCl and an increase in the chloride concentration slightly shifted both the pitting E pit and corrosion E cor potentials to more active values. In function of the conditions of treatment, the sheets of the alloy AA6061 undergo two types of localised corrosion process, leading to the formation of hemispherical and crystallographic pits. Polarisation resistance measurements in acidic (pH = 2) and alkaline chloride solutions (pH = 12) which are in good agreement with those of weight loss, show that the corrosion kinetic is minimised in slightly neutral solutions (pH = 6)

  14. Method for producing rapid pH changes

    Science.gov (United States)

    Clark, J.H.; Campillo, A.J.; Shapiro, S.L.; Winn, K.R.

    A method of initiating a rapid pH change in a solution comprises irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.

  15. The effects of intermittent exposure to low pH and oxygen conditions on survival and growth of juvenile red abalone

    Science.gov (United States)

    Kim, T. W.; Barry, J. P.; Micheli, F.

    2013-02-01

    Exposure of nearshore animals to hypoxic, low pH waters upwelled from below the continental shelf and advected near the coast may be stressful to marine organisms and lead to impaired physiological performance. We mimicked upwelling conditions in the laboratory and tested the effect of fluctuating exposure to water with low pH and/or low oxygen levels on the mortality and growth of juvenile red abalone (Haliotis rufescens, shell length 5-10 mm). Mortality rates of juvenile abalone exposed to low pH (7.5, total scale) and low O2 (40% saturation, 5 mg L-1) conditions for periods of 3 to 6 h every 3-5 days over 2 weeks did not differ from those exposed to control conditions (O2: 100% saturation, 12 mg L-1; pH 8.0). However, when exposure was extended to 24 h repeated twice over a 15 day period, juveniles experienced higher mortality in the low oxygen treatments compared to control conditions, regardless of pH levels (pH 7.5 vs. 8.0). Growth rates were reduced significantly when juveniles were exposed to low pH or low oxygen treatments and the growth was lowest when low pH exposure was combined with low O2. Furthermore, individual variation of growth rate increased when they were exposed to low pH and low O2 conditions. These results indicate that prolonged exposure to low oxygen levels is detrimental for the survival of red abalone, whereas both pH and oxygen is a crucial factor for their growth. However, given the higher individual variation in growth rate, they may have an ability to adapt to extended exposure to upwelling conditions.

  16. Dendritic Zinc Growth in Acid Electrolyte: Effect of the pH

    Science.gov (United States)

    Bengoa, Leandro N.; Pary, Paola; Seré, Pablo R.; Conconi, M. Susana; Egli, Walter A.

    2018-03-01

    In this paper, dendritic growth at the edges of electrogalvanized steel strip has been studied using a specially designed rotating washer electrode which simulates the fluid dynamic conditions and the current density distribution at the steel strip edge found in a production line. The effect of electrolyte pH and current density on dendritic growth in an acidic zinc plating bath (ZnSO4 and H2SO4) was addressed. The temperature was kept constant at 60 °C. Solution pH was adjusted to 1, 2 or 3 using different amounts of H2SO4. In addition, the influence of temperature on the pH of the solution was determined. The current density was set at 40 or 60 A/dm2, similar to that used in the industry. Deposits were characterized using SEM and XRD. The results showed that pH strongly affects dendrites shape, length and texture. Furthermore, the morphology of dendrites at the washer edge and of deposits on the flat portion of the washer changed considerably as solution pH was increased from 1 to 3. It was found that the morphology of dendrites at the washer edge stems from the morphology of the deposit on its flat portion, which in turn determines their shape.

  17. Tetrachloroethylene Removal Rate from Aqueous Solutions by Pumice Doped with Copper: An Evaluation of the Effect of pH

    Directory of Open Access Journals (Sweden)

    Ali Almasi

    2016-12-01

    Full Text Available Tetrachloroethylene (TCE is a chlorinated aliphatic hydrocarbon, used in many industries. Effective and efficient treatment of industrial wastewater, containing TCE, is one of the environmental requirements. The purpose of this study was to determine the role of alkaline environments in TCE removal rate from aqueous solutions, using copper-doped pumice. This experimental study was performed, using granulated pumice stones with a mesh 4 (8.4 mm in alkaline conditions; the samples were coated with copper. Copper-doped pumice was prepared as a bed at doses of 1, 2, and 3 g/L; the study was performed at pH ranges of 3, 7, and 11. Based on the results, copper-doped pumice showed good efficacy in TCE removal; in addition, its performance increased in alkaline conditions. Therefore, use of this stone for the treatment of wastewater, containing TCE, is effective due to its availability and low cost. Besides, it can be considered a good option, given its high efficiency in the absorption process.

  18. Electrical Conductivity and Chemical Composition of Soil Solution: Comparison of Solution Samplers in Tropical Soils

    Directory of Open Access Journals (Sweden)

    Davi Lopes do Carmo

    2016-01-01

    Full Text Available ABSTRACT Soil solution samplers may have the same working principle, but they differ in relation to chemical and physical characteristics, cost and handling, and these aspects exert influence on the chemical composition of the soil solution obtained. This study was carried out to evaluate, over time, the chemical composition of solutions extracted by Suolo Acqua, with the hydrophilic membrane (HM as a standard, using soils with contrasting characteristics, and to determine the relationship between electrical conductivity (EC and concentration of ions and pH of soil solution samples. This study was carried out under laboratory conditions, using three soils samples with different clay and organic matter (OM contents. Soil solution contents of F−, Cl−, NO−3, Br−, SO42−, Na+, NH4+, K+, Mg2+, Ca2+, were analyzed, as well as inorganic, organic, and total C contents, pH, and EC, in four successive sampling times. Soil solution chemical composition extracted by the Suolo Acqua sampler is similar to that collected by the HM, but the Suolo Acqua extracted more Na+ and soluble organic C than the HM solution. Solution EC, cation and anion concentrations, and soluble C levels are higher in the soil with greater clay and OM contents (Latossolo and Cambissolo in this case. Soil solution composition varied over time, with considerable changes in pH, EC, and nutrient concentrations, especially associated with soil OM. Thus, single and isolated sampling of the soil solution must be avoided, otherwise composition of the soil solution may not be correctly evaluated. Soil solution EC was regulated by pH, as well as the sum of cation and anion concentrations, and the C contents determined in the soil liquid phase.

  19. Hydrogen generation from aluminium corrosion in reactor containment spray solutions

    International Nuclear Information System (INIS)

    Frid, W.; Karlberg, G.; Sundvall, S.B.

    1982-01-01

    The aluminium corrosion experiments in reactor containment spray solutions, under the conditions expected to prevail during LOCA in BWR and PWR, were performed in order to investigate relationships between temperature, pH and hydrogen production rates. In order to simulate the conditions in a BWR containment realistic ratios between aluminium surface and water volume and between aluminium surface and oxygen volume were used. Three different aluminium alloys were exposed to spray solutions: AA 1050, AA 5052 and AA 6082. The corrosion rates were measured for BWR solutions (deaerated and aerated) with pH 5 and 9 at 50, 100 and 150 0 C. The pressure was constantly 0.8 MPa. The hydrogen production rate was measured by means of gas chromatography. In deionized BWR water the corrosion rates did not exceed about 0.05 mm/year in all cases, i.e. were practically independent of temperature and pH. Hydrogen concentrations were less than 0.1 vol.% in cooled dry gas. Corrosion rates and hydrogen production in PWR alkaline solution measured at pH 9.7 and 150 0 C were very high. AA 5052 alloy was the best material

  20. Chemical Composition and Evaluation of Nicotine, Tobacco Alkaloids, pH and Selected Flavors in e-Cigarette Cartridges and Refill Solutions

    Science.gov (United States)

    Lisko, Joseph G.; Tran, Hang; Stanfill, Stephen B.; Blount, Benjamin C.; Watson, Clifford H.

    2015-01-01

    Introduction Electronic cigarette (e-cigarette) use is increasing dramatically in developed countries, but little is known about these rapidly evolving products. This study analyzed and evaluated the chemical composition including nicotine, tobacco alkaloids, pH and flavors in 36 e-liquids brands from four manufacturers. Methods We determined the concentrations of nicotine, alkaloids, and select flavors and measured pH in solutions used in e-cigarettes. E-cigarette products were chosen based upon favorable consumer approval ratings from online review websites. Quantitative analyses were performed using strict quality assurance/quality control (QC) validated methods previously established by our lab for the measurement of nicotine, alkaloids, pH and flavors. Results Three-quarters of the products contained lower measured nicotine levels than the stated label values (6% - 42% by concentration). The pH for e-liquids ranged from 5.1 – 9.1. Minor tobacco alkaloids were found in all samples containing nicotine, and their relative concentrations varied widely among manufacturers. A number of common flavor compounds were analyzed in all e-liquids. Conclusions Free nicotine levels calculated from the measurement of pH correlated with total nicotine content. The direct correlation between the total nicotine concentration and pH suggests that the alkalinity of nicotine drives the pH of e-cigarette solutions. A higher percentage of nicotine exists in the more absorbable free form as total nicotine concentration increases. A number of products contained tobacco alkaloids at concentrations that exceed U.S. Pharmacopeia limits for impurities in nicotine used in pharmaceutical and food products. PMID:25636907

  1. A new medium for Caenorhabditis elegans toxicology and nanotoxicology studies designed to better reflect natural soil solution conditions.

    Science.gov (United States)

    Tyne, William; Lofts, Stephen; Spurgeon, David J; Jurkschat, Kerstin; Svendsen, Claus

    2013-08-01

    A new toxicity test medium for Caenorhabditis elegans is presented. The test solution is designed to provide a better representation of natural soil pore water conditions than currently available test media. The medium has a composition that can readily be modified to allow for studies of the influences of a range of environmentally relevant parameters on nematode biology and toxicology. Tests conducted in the new medium confirmed that nematodes' reproduction was possible at a range of solution pH levels, offering the potential to conduct toxicity studies under a variety of conditions. A test to establish silver nanoparticle and dissolved silver nitrate toxicity, a study type not feasible in M9 or agar media due to precipitation and nanoparticle agglomeration, indicated lower silver nanoparticle (median effective concentration [EC50] of 6.5 mg Ag/L) than silver nitrate (EC50 0.28 mg Ag/L) toxicity. Characterization identified stable nanoparticle behavior in the new test medium. Copyright © 2013 SETAC.

  2. The effect of aerobic corrosion on anaerobically-formed sulfide layers on carbon steel in dilute near-neutral pH saline solutions

    International Nuclear Information System (INIS)

    Sherar, B.W.A.; Keech, P.G.; Shoesmith, D.W.

    2013-01-01

    Highlights: •The corrosion rate is low when steel is exposed to anaerobic conditions (pH = 8.9). •An anaerobic corrosion with sulfide to aerobic switch increases the corrosion rate. •Aerobic conditions leads to corrosion and oxide deposition beneath FeS. •Continual air exposure leads to the blistering of the original FeS film. -- Abstract: The aerobic corrosion of pipeline steel was investigated in an aqueous sulfide solution by monitoring the corrosion potential and periodically measuring the polarization resistance. The properties and composition of the corrosion product deposits formed were determined using scanning electron microscopy, energy dispersive X-ray analysis, and Raman spectroscopy. The establishment of aerobic conditions leads to corrosion and (oxyhydr)oxide deposition beneath the anaerobically-formed mackinawite film originally present on the steel surface. This leads to blistering and spalling of the sulfide film. Chemical conversion of the mackinawite to Fe(III) (oxyhydr)oxides also occurs but is a relatively slow reaction

  3. Influence of alkaline (PH 8.3-12.0) and saline solutions on chemical, mineralogical and physical properties of two different bentonites - batch experiments at 25 deg. C

    International Nuclear Information System (INIS)

    Heikola, Tiina; Vuorinen, Ulla; Kumpulainen, Sirpa; Kiviranta, Leena; Korkeakoski, Petri

    2012-01-01

    Document available in extended abstract form only. Construction of a spent fuel repository deep in the bedrock will need supporting structures using cement materials. A part of them can be removed before closure but still it is estimated that about 1000 tonnes will remain in the host rock. Degradation of cementitious materials produces leachates of high pH. If such an alkaline plume reaches the bentonite buffer, it may induce mineralogical and chemical changes in bentonite over long term, and further affect the safety functions of the buffer. Laboratory experiments were done with the objective to gain data of possible alterations in mineralogical, chemical and physical properties of bentonites contacted with high-pH saline solutions. Two untreated, high grade, Na- and Ca-bentonites, were used in batch experiments, which were carried out in an anaerobic glove-box at 25±1 deg. C for 554 days. Each bentonite sample (20 g) was leached with approximately 3.8 L of leaching solution, which equals 190 mL/g of bentonite. The bentonites were leached with three types of simulated cement waters (pH 9.7, 11.3 and 12.0) and one saline groundwater simulate (pH 8.3) as a reference. The leaching solutions were 0.3 M, and contained NaCl and CaCl 2 , and trace amounts of SiO 2 , K, Br, Mg and SO 4 . Dissolved oxygen and carbon dioxide were removed from leaching solutions before mixing of bentonite in PC bottles. The samples were placed on a platform shaker in order to allow better contact between bentonite and the leaching solution. The evolution of pH in the samples was followed by measuring the pH-value of each sample in the solution phase approximately twice a week and the solution was renewed when values of two to three consecutive measurements did not change. On average, the leaching solution was renewed once a month. For each renewal of the leaching solution the phases were separated, the reacted solution withdrawn, and the chemical composition analysed. Before analysis the

  4. pH sensing in aqueous solutions using a MnO2 thin film electrodeposited on a glassy carbon electrode

    International Nuclear Information System (INIS)

    Cherchour, N.; Deslouis, C.; Messaoudi, B.; Pailleret, A.

    2011-01-01

    An electrolysis technique at a constant potential was used to develop a highly reproducible and fast elaboration method of adherent manganese dioxide thin films on a glassy carbon electrode from aqueous solutions containing sulfuric acid and manganese sulfate. The resulting films were found to have a nanostructured character presumably due rather to birnessite (δ-MnO 2 ) than to γ-MnO 2 , as suggested by their Raman and XRD signatures. They lead to modified electrodes that present an obvious although complex pH dependent potentiometric response. This sensor indeed showed a single slope non-Nernstian linear behaviour over the 1.5-12 pH range for increasing pH direction ('trace'), whereas a Nernstian two slopes linear behaviour was observed for decreasing pH direction ('re-trace'). Preliminary EIS experiments carried out at a pH value of 1.8 seem to reveal a sensitivity mechanism based on proton insertion process at least at highly acidic pH values.

  5. Addressing a Common Misconception: Ammonium Acetate as Neutral pH "Buffer" for Native Electrospray Mass Spectrometry

    Science.gov (United States)

    Konermann, Lars

    2017-09-01

    Native ESI-MS involves the transfer of intact proteins and biomolecular complexes from solution into the gas phase. One potential pitfall is the occurrence of pH-induced changes that can affect the analyte while it is still surrounded by solvent. Most native ESI-MS studies employ neutral aqueous ammonium acetate solutions. It is a widely perpetuated misconception that ammonium acetate buffers the analyte solution at neutral pH. By definition, a buffer consists of a weak acid and its conjugate weak base. The buffering range covers the weak acid pKa ± 1 pH unit. NH4 + and CH3-COO- are not a conjugate acid/base pair, which means that they do not constitute a buffer at pH 7. Dissolution of ammonium acetate salt in water results in pH 7, but this pH is highly labile. Ammonium acetate does provide buffering around pH 4.75 (the pKa of acetic acid) and around pH 9.25 (the pKa of ammonium). This implies that neutral ammonium acetate solutions electrosprayed in positive ion mode will likely undergo acidification down to pH 4.75 ± 1 in the ESI plume. Ammonium acetate nonetheless remains a useful additive for native ESI-MS. It is a volatile electrolyte that can mimic the solvation properties experienced by proteins under physiological conditions. Also, a drop from pH 7 to around pH 4.75 is less dramatic than the acidification that would take place in pure water. It is hoped that the habit of referring to pH 7 solutions as ammonium acetate "buffer" will disappear from the literature. Ammonium acetate "solution" should be used instead. [Figure not available: see fulltext.

  6. Influence of oxidation state on the pH dependence of hydrous iridium oxide films

    International Nuclear Information System (INIS)

    Steegstra, Patrick; Ahlberg, Elisabet

    2012-01-01

    Many electrochemical reactions taking place in aqueous solution consume or produce protons. The pH in the diffusion layer can therefore be significantly altered during the reaction and there is a need for in situ pH measurements tracing this near surface pH. In the present paper the rotating ring disc technique was used to measure near surface pH changes during oxygen reduction, utilising hydrous iridium oxide as the pH sensing probe. Before such experiments a good understanding of the pH sensing properties of these films is required and the impact of the oxidation state of the film on the pH sensing properties was investigated as well as the influence of solution redox species. The pH sensitivity (depicted by dE/dpH) was found to depend on the average oxidation state of the film in a manner resembling the cyclic voltammetry response. In all cases the pH response is “supernernstian” with more than one proton per electron. The origin of this behaviour is discussed in the context of acid-base properties of the film and the existence of both hydrous and anhydrous oxide phases. The pH response depends also on the redox properties of the solution but can be optimised for various purposes by conditioning the film at different potentials. This was clearly illustrated by adding hydrogen peroxide, an intermediate in the oxygen reduction reaction, to the solution. It was shown that hydrous iridium oxide can be used as a reliable in situ pH sensor provided that care is taken to optimise the oxidation state of the film.

  7. Formation of M-Like Intermediates in Proteorhodopsin in Alkali Solutions (pH ≥ ∼8.5) Where the Proton Release Occurs First in Contrast to the Sequence at Lower pH.

    Science.gov (United States)

    Tamogami, Jun; Sato, Keitaro; Kurokawa, Sukuna; Yamada, Takumi; Nara, Toshifumi; Demura, Makoto; Miyauchi, Seiji; Kikukawa, Takashi; Muneyuki, Eiro; Kamo, Naoki

    2016-02-23

    Proteorhodopsin (PR) is an outward light-driven proton pump observed in marine eubacteria. Despite many structural and functional similarities to bacteriorhodopsin (BR) in archaea, which also acts as an outward proton pump, the mechanism of the photoinduced proton release and uptake is different between two H(+)-pumps. In this study, we investigated the pH dependence of the photocycle and proton transfer in PR reconstituted with the phospholipid membrane under alkaline conditions. Under these conditions, as the medium pH increased, a blue-shifted photoproduct (defined as Ma), which is different from M, with a pKa of ca. 9.2 was produced. The sequence of the photoinduced proton uptake and release during the photocycle was inverted with the increase in pH. A pKa value of ca. 9.5 was estimated for this inversion and was in good agreement with the pKa value of the formation of Ma (∼ 9.2). In addition, we measured the photoelectric current generated by PRs attached to a thin polymer film at varying pH. Interestingly, increases in the medium pH evoked bidirectional photocurrents, which may imply a possible reversal of the direction of the proton movement at alkaline pH. On the basis of these findings, a putative photocycle and proton transfer scheme in PR under alkaline pH conditions was proposed.

  8. The study on the pH behavior of the HFSC leached solution. The development of model considering the pozzolanic reaction

    International Nuclear Information System (INIS)

    Yoshida, Yasushi; Mihara, Morihiro

    2005-09-01

    The development of low alkalinity cement (high fly-ash contained silica-fume cement, HFSC) has been carried out in JNC. Low alkalinity for this cement is achieved by adding pozzolan materials to ordinary portland cement and Ca ion attributed to high alkalinity is consumed by forming CHS gel. This report shows the calculation model to predict the composition for HFSC reacted solution which considers cement mineral dissolution/precipitation as equilibrium reactions and dissolution for pozzolan material as a kinetic reaction. The dissolution kinetic equation for pozzolan material is also derived from leaching experiment. This calculation model is applied to the leaching experiment where powdered HFSC was reacted with distilled water. As a result of comparison between calculation and experimental measurement at the early stage for leaching the tendency for pH, pH decrease from 12.5 to 11.5 drastically, could be interpreted by this calculation model, however, after this drastic pH decreasing pH predicted by calculation model also shows drastic decrease whereas pH for experiment decreased mildly around pH 11.5. It could be thought that this difference between experiment and calculation is caused by inappropriate modelling for CSH gel dissolution/precipitation of C/S value lower than 1.0. For this C/S range thermodynamic data for intermediate and end member for solid solution for CSH gel and in addition the reaction kinetic for CSH gel should be examined in detail. (author)

  9. Effect of Nitrogen Form and pH of Nutrient Solution on the Shoot Concentration of Phosphorus, Nitrate, and Nitrogen of Spinach in Hydroponic Culture

    OpenAIRE

    N. Najafi; M. Parsazadeh

    2010-01-01

    In order to study the effect of nitrogen form and pH of nutrient solution on the shoot concentration of P, nitrate, organic N + inorganic ammonium, and total N of spinach, a factorial experiment was conducted with two factors including pH of nutrient solution in three levels (4.5, 6.5 and 8.0) and nitrate to ammonium ratio of nutrient solution in five levels (100:0, 75:25, 50:50, 25:75 and 0:100). This factorial experiment was carried out in a completely randomized design with four replicatio...

  10. Gamma radiation and osmotic potential of the nutrient solution differentially affect macronutrient concentrations, pH and EC in chilhuacle pepper fruits

    International Nuclear Information System (INIS)

    Victor Garcia-Gaytan, Libia Iris Trejo-Tellez; Olga Tejeda-Sartorius; Maribel Ramirez-Martinez; Julian Delgadillo-Martinez; Fernando Carlos Gomez-Merino; Soledad Garcia-Morales

    2018-01-01

    Chilhuacle pepper (Capsicum annuum L.) seeds were exposed to gamma radiation (GR) doses (0, 10, 80 and 120 Gy), and plants were grown in hydroponics with different osmotic potentials (OP) (- 0.036, - 0.072, - 0.092, and - 0.108 MPa) in the nutrient solution. We measured the nutrient concentrations, pH and electrical conductivity (EC) in fruits at different time points after transplanting (70, 90 and 130 dat), and found the GR, nutrient solution OP and their interactions differentially affected N, P, K, Ca, and Mg concentrations, as well as pH and EC in chilhuacle peppers. (author)

  11. Long term corrosion behavior of the WAK-HLW glass in salt solutions

    International Nuclear Information System (INIS)

    Luckscheiter, B.; Nesovic, M.

    1998-01-01

    The corrosion behavior of the HLW glass GP WAK1 containing simulated HLW oxides from the WAK reprocessing plant in Karlsruhe is investigated in long-term corrosion experiments at high S/V ratios in two reference brines at 110 and 190 C. In case of the MgCl 2 -rich solution the leachate becomes increasingly acid with reaction time up to a final pH of about 3.5 at 190 C. In the NaCl-rich solution the pH rises to about 8.5 after one year of reaction. The release of soluble elements in MgCl 2 solution, under Si-saturated conditions, is proportional to the surface area of the sample and the release increases at 190 C according to a t 1/2 rate law. This time dependence may be an indication of diffusion controlled matrix dissolution. However, at 110 C the release of the mobile elements cannot be described by a t 1/2 rate law as the time exponents are much lower than 0.5. This difference in corrosion behavior may be explained by the higher pH of about 5 at 110 C. In case of NaCl solution under alkaline conditions, the release of soluble elements is not proportional to the surface area of the sample and it increases with time exponents much lower than 0.5. After one year of reaction at 190 C a sharp increase of the release values of some elements was observed. This increase might be explained by the high pH of the solution attained after one year. The corrosion mechanism in NaCl solution, as well as in MgCl 2 solution at 110 C, has not yet been explained. By corrosion experiments in water at constant pH values between 2 and 10, it could be shown that the time exponents of the release of Li and B decrease with increasing pH of the solution. This result can explain qualitatively the differences found in the corrosion behavior of the glass under the various conditions

  12. Semi-mechanistic partial buffer approach to modeling pH, the buffer properties, and the distribution of ionic species in complex solutions.

    Science.gov (United States)

    Dougherty, Daniel P; Da Conceicao Neta, Edith Ramos; McFeeters, Roger F; Lubkin, Sharon R; Breidt, Frederick

    2006-08-09

    In many biological science and food processing applications, it is very important to control or modify pH. However, the complex, unknown composition of biological media and foods often limits the utility of purely theoretical approaches to modeling pH and calculating the distributions of ionizable species. This paper provides general formulas and efficient algorithms for predicting the pH, titration, ionic species concentrations, buffer capacity, and ionic strength of buffer solutions containing both defined and undefined components. A flexible, semi-mechanistic, partial buffering (SMPB) approach is presented that uses local polynomial regression to model the buffering influence of complex or undefined components in a solution, while identified components of known concentration are modeled using expressions based on extensions of the standard acid-base theory. The SMPB method is implemented in a freeware package, (pH)Tools, for use with Matlab. We validated the predictive accuracy of these methods by using strong acid titrations of cucumber slurries to predict the amount of a weak acid required to adjust pH to selected target values.

  13. Passive behaviour of alloy corrosion-resistant steel Cr10Mo1 in simulating concrete pore solutions with different pH

    International Nuclear Information System (INIS)

    Ai, Zhiyong; Jiang, Jinyang; Sun, Wei; Song, Dan; Ma, Han; Zhang, Jianchun; Wang, Danqian

    2016-01-01

    Highlights: • A new alloy corrosion-resistant steel Cr10Mo1 is developed for reinforcing rebar of concrete in severe environments. • The effects of pH on the passive behaviour of Cr10Mo1 steel compared with plain carbon steel were studied systematically by electrochemical techniques and surface analysis. • The mechanism for self-reinforcing passivity against carbonation of the corrosion-resistant steel is revealed. - Abstract: The passive behaviour of new alloy corrosion-resistant steel Cr10Mo1 and plain carbon steel (as a comparison) in simulating concrete pore solutions of different pH (ranging from 13.5 to 9.0) under open circuit potential conditions, was evaluated by various electrochemical techniques: potentiodynamic polarization, capacitance measurements and electrochemical impedance spectroscopy. The chemical composition and structure of passive films were investigated by X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS). The electrochemical responses of passive films show that Cr10Mo1 steel has an increasing passivity with pH decreasing while carbon steel dose conversely, revealing carbonation does no negative effect on passivation of the corrosion-resistant steel. SIMS reveals that the passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer mainly consisting of Fe oxides and hydroxides, and an inner layer enriched in Cr species, while only a Fe-concentrated layer for carbon steel. According to the XPS analysis results, as the pH decreases, more stable and protective Cr oxides are enriched in the film on Cr10Mo1 steel while Fe oxides gradually decompose. Higher content of Cr oxides in the film layer provides Cr10Mo1 corrosion-resistant steel more excellent passivity at lower pH.

  14. Passive behaviour of alloy corrosion-resistant steel Cr10Mo1 in simulating concrete pore solutions with different pH

    Energy Technology Data Exchange (ETDEWEB)

    Ai, Zhiyong, E-mail: 230139452@seu.edu.cn [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Construction Materials, Nanjing 211189, Jiangsu (China); Jiang, Jinyang, E-mail: jiangjinyang16@163.com [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Construction Materials, Nanjing 211189, Jiangsu (China); Sun, Wei, E-mail: sunwei@seu.edu.cn [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Construction Materials, Nanjing 211189, Jiangsu (China); Song, Dan, E-mail: songdancharls@hhu.edu.cn [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Construction Materials, Nanjing 211189, Jiangsu (China); College of Mechanics and Materials, Hohai University, Nanjing 210098, Jiangsu (China); Ma, Han, E-mail: mahan-iris@shasteel.cn [Research Institute of Jiangsu Shasteel Iron and Steel, Zhangjiagang 215625, Jiangsu (China); Zhang, Jianchun, E-mail: Zhangjc-iris@shasteel.cn [Research Institute of Jiangsu Shasteel Iron and Steel, Zhangjiagang 215625, Jiangsu (China); Wang, Danqian, E-mail: wonderbaba@126.com [School of Materials Science and Engineering, Southeast University, Nanjing 211189, Jiangsu (China); Jiangsu Key Laboratory of Construction Materials, Nanjing 211189, Jiangsu (China)

    2016-12-15

    Highlights: • A new alloy corrosion-resistant steel Cr10Mo1 is developed for reinforcing rebar of concrete in severe environments. • The effects of pH on the passive behaviour of Cr10Mo1 steel compared with plain carbon steel were studied systematically by electrochemical techniques and surface analysis. • The mechanism for self-reinforcing passivity against carbonation of the corrosion-resistant steel is revealed. - Abstract: The passive behaviour of new alloy corrosion-resistant steel Cr10Mo1 and plain carbon steel (as a comparison) in simulating concrete pore solutions of different pH (ranging from 13.5 to 9.0) under open circuit potential conditions, was evaluated by various electrochemical techniques: potentiodynamic polarization, capacitance measurements and electrochemical impedance spectroscopy. The chemical composition and structure of passive films were investigated by X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS). The electrochemical responses of passive films show that Cr10Mo1 steel has an increasing passivity with pH decreasing while carbon steel dose conversely, revealing carbonation does no negative effect on passivation of the corrosion-resistant steel. SIMS reveals that the passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer mainly consisting of Fe oxides and hydroxides, and an inner layer enriched in Cr species, while only a Fe-concentrated layer for carbon steel. According to the XPS analysis results, as the pH decreases, more stable and protective Cr oxides are enriched in the film on Cr10Mo1 steel while Fe oxides gradually decompose. Higher content of Cr oxides in the film layer provides Cr10Mo1 corrosion-resistant steel more excellent passivity at lower pH.

  15. A miniature integrated multimodal sensor for measuring pH, EC and temperature for precision agriculture.

    Science.gov (United States)

    Futagawa, Masato; Iwasaki, Taichi; Murata, Hiroaki; Ishida, Makoto; Sawada, Kazuaki

    2012-01-01

    Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si(3)N(4) membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.

  16. Influence of pH on Cr(VI) ions removal from aqueous solutions using carboxymethyl cellulose-based hydrogel as adsorbent

    Science.gov (United States)

    Anah, L.; Astrini, N.

    2017-03-01

    The major problem in heavy metal pollution is that these metals are not biodegradable and accordingly accumulate in the bodies of living organisms, causing dangerous diseases and serious cell disorder. According to World Health Organization (WHO), the long term exposure of Cr(VI) levels of over 0.1 ppm causes respiratory problems, liver and kidney damage, and carcinogenicity.Due to its easy operation and of various cheap adsorbents development, adsorption has been proved to be efficient and most economically attractive technique and feasible to the removal of toxic heavy metal from wastewater. The study aimed to report the removal of Cr(VI) ions from aqueous solutions through adsorption process using carboxymethyl cellulose-graft-poly(acrylic acid) (CMC-g-PAA) hydrogel as adsorbent.Effect of pH was studied to remove hexavalent chromium.Graft copolymerization of poly(acrylic acid) onto carboxymethyl cellulose was carried out in the presence of benzoyl peroxide redox initiator and methylenbisacrylamide as crosslinker agent. Batch experiments were carried out to investigate the effects ofinitial pH.The adsorption of Cr(VI) ions as a function of pH was conducted in the initial pH range of 1 to 8. The results indicated that acidic pH strongly favored the adsorption. The optimum pH for adsorption of Cr(VI) ranged from 1 to 3, and the maximum uptake of Cr(VI) from the solution was 6.53 mg/g at pH 1 and 30°C. FTIR spectroscopy, SEM analyses were performed on the adsorbent before and after Cr(VI) binding. All analyses confirmed the complexation of Cr(VI) ions on the adsorbent.

  17. Passivation behavior of a ferritic stainless steel in concentrated alkaline solutions

    Directory of Open Access Journals (Sweden)

    Arash Fattah-alhosseini

    2015-10-01

    Full Text Available The passivation behavior of AISI 430 ferritic stainless steel was investigated in concentrated alkaline solutions in relation to several test parameters, using electrochemical techniques. Increasing solution pH (varying from 11.5 to 14.0 leads to an increase in the corrosion rate of the alloy. Mott–Schottky analysis revealed that passive films formed on AISI 430 ferritic stainless steel behave as n-type semiconductor and the donor densities increased with pH. Electrochemical impedance spectroscopy (EIS results showed that the reciprocal capacitance of the passive film is directly proportional to its thickness, which decreases with pH increase. The results revealed that for this ferritic stainless steel in concentrated alkaline solutions, decreasing the solution pH offers better conditions for forming passive films with higher protection behavior, due to the growth of a much thicker and less defective film.

  18. Developments in the monitoring and control of Eh and pH conditions in hydrothermal experiments

    International Nuclear Information System (INIS)

    Myers, J.; Ulmer, G.C.; Grandstaff, D.E.; Brozdowski, R.; Danielson, M.J.; Koski, O.H.

    1984-01-01

    In the design of a high-level nuclear waste repository it is essential to obtain accurate groundwater Eh-pH data. Design considerations such as the choice of matrix for the waste form, type and dimensions of canister material, use of buffers, and type and amount of backfill would all benefit from an exact knowledge of oxidation potentials (Eh) and acidity levels (pH) of the groundwater. The Basalt Waste Isolation Project (BWIP) has initiated a research effort to develop sensors which can be mounted in autoclaves to provide constant monitoring of the Eh-pH conditions that exist during waste form/barrier material/groundwater hydrothermal interaction tests. Sensors must withstand temperatures up to 300 0 C and pressures up to 300 bars. This report considers Teflon hydrogen diffusion membranes and zirconia pH sensors. The development of these sensors represents a significant advance in the environmental monitoring of Eh and pH conditions at elevated temperatures and pressures

  19. Effect of chitosan on the heat stability of whey protein solution as a function of pH.

    Science.gov (United States)

    Zhao, Zhengtao; Xiao, Qian

    2017-03-01

    Chitosan was reported to interact with proteins through electrostatic interactions. Their interaction was influenced by pH, which was not fully characterized. Further research on the interactions between protein and chitosan at different pH and their influence on the thermal denaturation of proteins is necessary. In this research, the effect of chitosan on the heat stability of whey protein solution at pH 4.0-6.0 was studied. At pH 4.0, a small amount chitosan was able to prevent the heat-induced denaturation and aggregation of whey protein molecules. At higher pH values (5.5 and 6.0), whey proteins complexed with chitosan through electrostatic attraction. The formation of chitosan-whey protein complexes at pH 5.5 improved the heat stability of dispersions and no precipitation could be detected up to 20 days. The dispersion with a medium amount of chitosan (chitosan:whey protein 1:5) produced the most stable particles, which had an average radius of 135 ± 14 nm and a zeta potential value of 36 ± 1 mV. In contrast, at pH 6.0 only the dispersion with a high amount of chitosan (chitosan:whey protein 1:2) showed good shelf stability up to 20 days. It was possible to produce heat-stable whey protein beverages by regulating the interaction between chitosan and whey protein molecules. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  20. The influence of surface modification, coating agents and pH value of aqueous solutions on physical properties of magnetite nanoparticles investigated by ESR method

    Energy Technology Data Exchange (ETDEWEB)

    Dobosz, Bernadeta, E-mail: benia@amu.edu.pl [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Krzyminiewski, Ryszard [Medical Physics Division, Faculty of Physics, Adam Mickiewicz University, Umultowska 85, 61-614 Poznań (Poland); Kurczewska, Joanna; Schroeder, Grzegorz [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland)

    2017-05-01

    The article presents the results of electron spin resonance (ESR) studies for aqueous solutions of functionalized superparamagnetic iron(II,III) oxide nanoparticles. The samples studied differed in type of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions. The ESR spectra of the samples were obtained at room temperature and at 230 K. The field cooling (FC) experiment was performed for selected samples, and the effective anisotropy field (H{sub K2}) and the first order magnetocrystalline anisotropy constant (K{sub 1}) was calculated. The process of the nanoparticles diffusion in different environments (human blood, human serum) forced by an inhomogeneous magnetic field was monitored and their interactions with different solvents have been discussed. It has been shown that ESR method is useful to observe the impact of organic ligands at the magnetite surface, type of coating agent and pH value of aqueous solutions on the properties of iron(II,III) oxide nanoparticles. - Highlights: • The influence of different organic ligands, coatings and pH values of aqueous solutions on the physical properties of the magnetite nanoparticles studied by ESR method. • Nanoparticles diffusion forced by inhomogeneous magnetic field monitored by ESR and explained. • A narrow line separated in ESR spectra by CREM. • The influence of different coatings and pH values of aqueous solutions on ESR spectra of TEMPO attached to the magnetite core.

  1. Passivation Characteristics of Alloy Corrosion-Resistant Steel Cr10Mo1 in Simulating Concrete Pore Solutions: Combination Effects of pH and Chloride.

    Science.gov (United States)

    Ai, Zhiyong; Sun, Wei; Jiang, Jinyang; Song, Dan; Ma, Han; Zhang, Jianchun; Wang, Danqian

    2016-09-01

    The electrochemical behaviour for passivation of new alloy corrosion-resistant steel Cr10Mo1 immersed in alkaline solutions with different pH values (13.3, 12.0, 10.5, and 9.0) and chloride contents (0.2 M and 1.0 M), was investigated by various electrochemical techniques: linear polarization resistance, electrochemical impedance spectroscopy and capacitance measurements. The chemical composition and structure of passive films were determined by XPS. The morphological features and surface composition of the immersed steel were evaluated by SEM together with EDS chemical analysis. The results evidence that pH plays an important role in the passivation of the corrosion-resistant steel and the effect is highly dependent upon the chloride contents. In solutions with low chloride (0.2 M), the corrosion-resistant steel has notably enhanced passivity with pH falling from 13.3 to 9.0, but does conversely when in presence of high chloride (1.0 M). The passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer enriched in Fe oxides and hydroxides, and an inner layer, rich in Cr species. The film composition varies with pH values and chloride contents. As the pH drops, more Cr oxides are enriched in the film while Fe oxides gradually decompose. Increasing chloride promotes Cr oxides and Fe oxides to transform into their hydroxides with little protection, and this is more significant at lower pH (10.5 and 9.0). These changes annotate passivation characteristics of the corrosion-resistant steel in the solutions of different electrolyte.

  2. Soil solution Zn and pH dynamics in non-rhizosphere soil and in the rhizosphere of Thlaspi caerulescens grown in a Zn/Cd-contaminated soil.

    Science.gov (United States)

    Luo, Y M; Christie, P; Baker, A J

    2000-07-01

    Temporal changes in soil solution properties and metal speciation were studied in non-rhizosphere soil and in the rhizosphere of the hyperaccumulator Thlaspi caerulescens J. & C. Presl (population from Prayon, Belgium) grown in a Zn- and Cd-contaminated soil. This paper focuses on soil solution Zn and pH dynamics during phytoextraction. The concentration of Zn in both non-rhizosphere and rhizosphere soil solutions decreased from 23 mg/l at the beginning to 2 mg/l at the end of the experiment (84 days after transplanting of seedlings), mainly due to chemical sorption. There was no significant difference in overall Zn concentration between the planted and the unplanted soil solutions (P > 0.05). Soil solution pH decreased initially and then increased slightly in both planted and unplanted soil zones. From 60 to 84 days after transplanting, the pH of the rhizosphere soil solution was higher than that of non-rhizosphere soil solution (P<0.05). Zn uptake by the hyperaccumulator plants was 8.8 mg per pot (each containing 1 kg oven-dry soil) on average. The data indicate that the potential of T. caerulescens to remove Zn from contaminated soil may not be related to acidification of the rhizosphere.

  3. Influence of the solution pH in the 6-mercaptopurine self-assembled monolayer (6MP-SAM) on a Au(111) single-crystal electrode.

    Science.gov (United States)

    Madueño, Rafael; García-Raya, Daniel; Viudez, Alfonso J; Sevilla, José M; Pineda, Teresa; Blázquez, Manuel

    2007-10-23

    Self-assembled monolayers (SAMs) of 6-mercaptopurine (6MP) have been prepared on a Au(111) single-crystal electrode by immersion of the metal surface in a 100 microM 6MP and 0.01 M HClO4 solution. The 6MP-SAM Au(111) single-crystal electrodes were transferred to the cell and allowed to equilibrate with the different aqueous working solutions before the electrochemical experiments. The influence of the solution pH was studied by cyclic voltammetry, double layer capacitance curves, and electrochemical impedance spectroscopy. The electrochemical behavior of the 6MP-SAM in acetic acid at pH 4 presents important differences in comparison to that obtained in 0.1 M KOH solutions. Cyclic voltammograms for the reductive desorption process in acid medium are broad and show some features that can be explained by a phase transition between a chemisorbed and a physisorbed state of the 6MP molecules. The low solubility of these molecules in acid medium could explain this phenomenon and the readsorption of the complete monolayer when the potential is scanned in the positive direction. The variation of the double-layer capacitance values in the potential range of monolayer stability with the pH suggests that the acid-base chemistry of the 6MP molecules is playing a role. This fact has been studied by following the variations of the electron-transfer rate constant of the highly charged redox probes as are Fe(CN)(6)-3/-4 and Ru(NH3)(6)+3/+2 as a function of solution pH. The apparent surface pKa value for the 6MP-SAM (pKa approximately 8) is explained by the total conversion of the different 6MP tautomers that exist in solution to the thiol species in the adsorbed state.

  4. pH sensing in aqueous solutions using a MnO{sub 2} thin film electrodeposited on a glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Cherchour, N. [Laboratoire de Technologie des Materiaux et Genie des Procedes (LTMGP), Departement de Genie des Procedes, Universite A. Mira, Route de Targa Ouzemmour, 06000 Bejaia (Algeria); CNRS, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France); UPMC Univ. Paris VI, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France); Deslouis, C. [CNRS, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France); UPMC Univ. Paris VI, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France); Messaoudi, B. [Laboratoire de Technologie des Materiaux et Genie des Procedes (LTMGP), Departement de Genie des Procedes, Universite A. Mira, Route de Targa Ouzemmour, 06000 Bejaia (Algeria); Pailleret, A., E-mail: alain.pailleret@upmc.fr [CNRS, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France); UPMC Univ. Paris VI, UPR 15, Laboratoire Interfaces et Systemes Electrochimiques (LISE, case courrier 133), 4 Place Jussieu, F-75005 Paris (France)

    2011-11-30

    An electrolysis technique at a constant potential was used to develop a highly reproducible and fast elaboration method of adherent manganese dioxide thin films on a glassy carbon electrode from aqueous solutions containing sulfuric acid and manganese sulfate. The resulting films were found to have a nanostructured character presumably due rather to birnessite ({delta}-MnO{sub 2}) than to {gamma}-MnO{sub 2}, as suggested by their Raman and XRD signatures. They lead to modified electrodes that present an obvious although complex pH dependent potentiometric response. This sensor indeed showed a single slope non-Nernstian linear behaviour over the 1.5-12 pH range for increasing pH direction ('trace'), whereas a Nernstian two slopes linear behaviour was observed for decreasing pH direction ('re-trace'). Preliminary EIS experiments carried out at a pH value of 1.8 seem to reveal a sensitivity mechanism based on proton insertion process at least at highly acidic pH values.

  5. Thermal stability of tagatose in solution.

    Science.gov (United States)

    Luecke, Katherine J; Bell, Leonard N

    2010-05-01

    Tagatose, a monosaccharide similar to fructose, has been shown to behave as a prebiotic. To deliver this prebiotic benefit, tagatose must not degrade during the processing of foods and beverages. The objective of this study was to evaluate the thermal stability of tagatose in solutions. Tagatose solutions were prepared in 0.02 and 0.1 M phosphate and citrate buffers at pHs 3 and 7, which were then held at 60, 70, and 80 degrees C. Pseudo-1st-order rate constants for tagatose degradation were determined. In citrate and phosphate buffers at pH 3, minimal tagatose was lost and slight browning was observed. At pH 7, tagatose degradation rates were enhanced. Degradation was faster in phosphate buffer than citrate buffer. Higher buffer concentrations also increased the degradation rate constants. Enhanced browning accompanied tagatose degradation in all buffer solutions at pH 7. Using the activation energies for tagatose degradation, less than 0.5% and 0.02% tagatose would be lost under basic vat and HTST pasteurization conditions, respectively. Although tagatose does breakdown at elevated temperatures, the amount of tagatose lost during typical thermal processing conditions would be virtually negligible. Practical Application: Tagatose degradation occurs minimally during pasteurization, which may allow for its incorporation into beverages as a prebiotic.

  6. Chemical Composition and Evaluation of Nicotine, Tobacco Alkaloids, pH, and Selected Flavors in E-Cigarette Cartridges and Refill Solutions.

    Science.gov (United States)

    Lisko, Joseph G; Tran, Hang; Stanfill, Stephen B; Blount, Benjamin C; Watson, Clifford H

    2015-10-01

    Electronic cigarette (e-cigarette) use is increasing dramatically in developed countries, but little is known about these rapidly evolving products. This study analyzed and evaluated the chemical composition including nicotine, tobacco alkaloids, pH, and flavors in 36 e-liquids brands from 4 manufacturers. We determined the concentrations of nicotine, alkaloids, and select flavors and measured pH in solutions used in e-cigarettes. E-cigarette products were chosen based upon favorable consumer approval ratings from online review websites. Quantitative analyses were performed using strict quality assurance/quality control validated methods previously established by our lab for the measurement of nicotine, alkaloids, pH, and flavors. Three-quarters of the products contained lower measured nicotine levels than the stated label values (6%-42% by concentration). The pH for e-liquids ranged from 5.1-9.1. Minor tobacco alkaloids were found in all samples containing nicotine, and their relative concentrations varied widely among manufacturers. A number of common flavor compounds were analyzed in all e-liquids. Free nicotine levels calculated from the measurement of pH correlated with total nicotine content. The direct correlation between the total nicotine concentration and pH suggests that the alkalinity of nicotine drives the pH of e-cigarette solutions. A higher percentage of nicotine exists in the more absorbable free form as total nicotine concentration increases. A number of products contained tobacco alkaloids at concentrations that exceed U.S. pharmacopeia limits for impurities in nicotine used in pharmaceutical and food products. © Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  7. Electrodialytic extraction of Cr from water-washed MSWI fly ash by changing pH and redox conditions

    DEFF Research Database (Denmark)

    Chen, Wan; Kirkelund, Gunvor Marie; Jensen, Pernille Erland

    2018-01-01

    Electrodialytic process offers a range of possibilities to waste management by electrodialytic separation (EDS) of heavy metals, depending on how the process is designed. Using three EDS cell setups (two two-compartment and one three-compartment) and their combinations, the extraction of Cr from...... rate of 27.5%, is an improvement on the single-step that extracted maximum 3.1%. The highest extraction was obtained due to the combined extraction of Cr(III) under low pH (accompanied with high redox) conditions and Cr(VI) under high pH (low redox) conditions subsequently. The Cr leaching from...... the treated ashes with acidic pH was lower than from those with alkaline pH; after the three-step treatment, Cr leaching was much lower from the coarse fraction (> 50 µm), as compared to the fine (≤ 50 µm) or the unsieved ash. As for the coarse fraction, two/three-step treatment reduced the leaching of Cr...

  8. PENENTUAN WAKTU KONTAK DAN pH OPTIMUM PENYERAPAN METILEN BIRU MENGGUNAKAN ABU SEKAM PADI

    Directory of Open Access Journals (Sweden)

    Anung Riapanitra

    2006-11-01

    Full Text Available Dyes are widely used for colouring in textile industries, significant losses occur during the manufacture and processing of the product, and these lost chemical are discharged in surrounding effluent. Adsorption of dyes is an effective technology for treatment of wastewater contaminated by the mismanaged of different types of dyes. In this research, we investigated the potential of rice husk ash for removal of methylene blue dyeing agent in aqueous system. The aim of this research is to find out the optimum contact time and pH on the adsorption of methylene blue using rice husk ash. Batch kinetics studies were carried out under varying experimental condition of contact time and pH. An adsorption equilibrium condition was reached within 10 minutes and the optimum condition for adsorption was at pH 3. The adsorption of methylene blue was decreasing with decreasing the solution pH value.

  9. Trimerization Dictates Solution Opalescence of a Monoclonal Antibody.

    Science.gov (United States)

    Yang, Teng-Chieh; Langford, Alex Jacob; Kumar, Sandeep; Ruesch, John Carl; Wang, Wei

    2016-08-01

    Opalescence, sometimes observed in antibody solutions, is thought to be mediated by light scattering of soluble oligomers or insoluble particulates. However, mechanistic features, such as stoichiometry and self-association affinity of oligomeric species related to opalescence, are poorly understood. Here, opalescence behavior of a monoclonal antibody (mAb-1) solution was studied over a wide range of solution conditions including different protein concentrations, pH, and in the presence or absence of salt. Hydrodynamic and thermodynamic properties of mAb-1 solutions were studied by analytical ultracentrifugation and dynamic light scattering. Opalescence in mAb-1 solutions is pH and concentration dependent. The degree of opalescence correlates with reversible monomer-trimer equilibrium detected by analytical ultracentrifugation. Increased trimer formation corresponds to increased opalescence in mAb-1 solutions at higher pH and protein concentrations. Addition of NaCl shifts this equilibrium toward monomer and reduces solution opalescence. This study demonstrates that opalescence in mAb-1 solutions does not arise from the light scattering of monomer or random molecular self-associations but is strongly correlated with a specific self-association stoichiometry and affinity. Importantly, at pH 5.5 (far below isoelectric point of mAb-1), the solution is not opalescent and with nonideal behavior. This study also dissects several parameters to describe the hydrodynamic and thermodynamic nonideality. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  10. Adsorption of phenol by activated carbon: Influence of activation methods and solution pH

    International Nuclear Information System (INIS)

    Beker, Ulker; Ganbold, Batchimeg; Dertli, Halil; Guelbayir, Dilek Duranoglu

    2010-01-01

    Cherry stone based activated carbon derived from a canning industry was evaluated for its ability to remove phenol from an aqueous solution in a batch process. A comparative adsorption on the uptake of phenol by using commercial activated carbon (Chemviron CPG-LF), and two non-functional commercial polymeric adsorbents (MN-200 and XAD-2) containing a styrene-divinylbenzene macroporous hyperreticulated network have been also examined. Equilibrium studies were conducted in 25 mg L -1 initial phenol concentrations, 6.5-9 solution pH and at temperature of 30 deg. C. The experimental data were analyzed by the Langmuir and Freundlich isotherm models. Besides, the cherry stone based activated carbons were carried out by using zinc chloride and KOH activation agents at different chemical ratios (activating agent/precursor), to develop carbons with well-developed porosity. The cherry stone activated carbon prepared using KOH as a chemical agent showed a high surface area. According to the results, activated carbons had excellent adsorptive characteristics in comparison with polymeric sorbents and commercial activated carbon for the phenol removal from the aqueous solutions.

  11. Effect of the pH in the adsorption and in the immersion enthalpy of monohydroxylated phenols from aqueous solutions on activated carbons.

    Science.gov (United States)

    Blanco-Martínez, D A; Giraldo, L; Moreno-Piraján, J C

    2009-09-30

    An activated carbon Carbochem--PS230 was modified by chemical and thermal treatment in flow of H(2) in order to evaluate the influence of the activated carbon chemical surface in the adsorption of the monohydroxylated phenols. The solid-solution interaction was determined by analyzing the adsorption isotherms at 298 K at pH 7, 9 and 11 during 48 h. The adsorption capacity of activated carbons increases when the pH solution decreases. The amount adsorbed increases in the reduced carbon at the maximum adsorption pH and decreases in the oxidized carbon. In the sample of granulated activated carbon, CAG, the monohydroxylated phenols adsorption capacity diminishes in the following order catechol >hydroquinone >resorcinol, at the three pH values. The experimental data are evaluated with Freundlich's and Langmuir's models. The immersion enthalpies are determined and increase with the retained amount, ranging between 21.5 and 45.7 J g(-1). In addition, the immersion enthalpies show more interaction with the reduced activated carbon that has lower total acidity contents.

  12. Periodic solutions of asymptotically linear Hamiltonian systems without twist conditions

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Rong [Coll. of Mathematics and Physics, Nanjing Univ. of Information Science and Tech., Nanjing (China); Dept. of Mathematics, Southeast Univ., Nanjing (China); Zhang Dongfeng [Dept. of Mathematics, Southeast Univ., Nanjing (China)

    2010-05-15

    In dynamical system theory, especially in many fields of applications from mechanics, Hamiltonian systems play an important role, since many related equations in mechanics can be written in an Hamiltonian form. In this paper, we study the existence of periodic solutions for a class of Hamiltonian systems. By applying the Galerkin approximation method together with a result of critical point theory, we establish the existence of periodic solutions of asymptotically linear Hamiltonian systems without twist conditions. Twist conditions play crucial roles in the study of periodic solutions for asymptotically linear Hamiltonian systems. The lack of twist conditions brings some difficulty to the study. To the authors' knowledge, very little is known about the case, where twist conditions do not hold. (orig.)

  13. pH variations during diafiltration due to buffer nonidealities.

    Science.gov (United States)

    Baek, Youngbin; Yang, Deyu; Singh, Nripen; Arunkumar, Abhiram; Ghose, Sanchayita; Li, Zheng Jian; Zydney, Andrew L

    2017-11-01

    Diafiltration is used for final formulation of essentially all biotherapeutics. Several studies have demonstrated that buffer/excipient concentrations in the final diafiltered product can be different than that in the diafiltration buffer due to interactions between buffer species and the protein product. However, recent work in our lab has shown variations in solution pH that are largely independent of the protein concentration during the first few diavolumes. Our hypothesis is that these pH variations are due to nonidealities in the acid-base equilibrium coefficient. A model was developed for the diafiltration process accounting for the ionic strength dependence of the pK a . Experimental results obtained using phosphate and histidine buffers were in excellent agreement with model predictions. A decrease in ionic strength leads to an increase in the pK a for the phosphate buffer, causing a shift in the solution pH, even under conditions where the initial feed and the diafiltration buffer are at the same pH. This effect could be eliminated by matching the ionic strength of the feed and diafiltration buffer. The experimental data and model provide new insights into the factors controlling the pH profile during diafiltration processes. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1555-1560, 2017. © 2017 American Institute of Chemical Engineers.

  14. A Miniature Integrated Multimodal Sensor for Measuring pH, EC and Temperature for Precision Agriculture

    Directory of Open Access Journals (Sweden)

    Hiroaki Murata

    2012-06-01

    Full Text Available Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC and temperature sensors. An ISFET with a Si3N4 membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.

  15. Tuning interionic interaction by rationally controlling solution pH for highly selective colorimetric sensing of arginine.

    Science.gov (United States)

    Qian, Qin; Hao, Jie; Ma, Wenjie; Yu, Ping; Mao, Lanqun

    2016-04-01

    Direct selective sensing of arginine in central nervous systems remains very essential to understanding of the molecular basis of some physiological events. This study presents the first demonstration on a simple yet effective method for arginine sensing with gold nanoparticles (Au-NPs) as the signal readout. The rationale for the method is based on the pH-dependent feature of the interionic interaction between cysteine and arginine. At pH 6.0, cysteine can only interact with arginine through the ion-pair interaction and such interaction can lead to the changes in both the solution color and UV-vis spectrum of the cysteine-protected Au-NPs upon the addition of arginine. These changes are further developed into an analytical strategy for effective sensing of arginine by rationally controlling the pH values of Au-NP dispersions with the ratio of the absorbance at 650 nm (A 650) to that at 520 nm (A 520) (A 650/A 520) as a parameter for analysis. The method is responsive to arginine without the interference from other species in the cerebral system; under the optimized conditions, the A 650/A 520 values are linear with the concentration of arginine within a concentration range from 0.80 to 64 μM, yet remain unchanged with the addition of other kinds of amino acids or the species in the central nervous system into the Au-NPs dispersion containing cysteine. The method demonstrated here is reliable and robust and could thus be used for detection of the increase of arginine in central nervous systems.

  16. The effect of high pH alkaline solutions on the mineral stability of the Boom Clay - Batch experiments at 60 deg. C

    International Nuclear Information System (INIS)

    Honty, M.; De Craen, M.; Wang, L.; Madejova, J.; Czimerova, A.; Pentrak, M.; Stricek, I.; Van Geet, M.

    2010-01-01

    Boom Clay is currently viewed as a reference host formation for studies on deep geological disposal of radioactive waste in Belgium. The interactions between bulk rock Boom Clay and 0.1 M KOH, 0.1 M NaOH, 0.1 M Ca(OH) 2 , young cement water and evolved cement water solutions, ranging in pH from 12.5 to 13.2, were examined as static batch experiments at 60 deg. C to simulate alkaline plume perturbations, which are expected to occur in the repository due to the presence of concrete. Both liquids and solids were investigated at specific times between 90 and 510 days in order to control the elemental budget and to search for potential mineralogical alterations. Also, the clay fraction was separated from the whole-rock Boom Clay at the end of each run and characterized for its mineralogical composition. Thereby, the importance of the mineral matrix to buffer the alkaline attack and the role of organic matter to protect clay minerals were also addressed. The results indicate that the degree of geochemical perturbation in Boom Clay is dependent on the initial pH of the applied solution together with the nature of the major cation in the reactant fluids. The higher the initial pH of the media, the stronger its interaction with Boom Clay. No major non-clay mineralogical alteration of the Boom Clay was detected, but dissolution of kaolinite, smectite and illite occurred within the studied experimental conditions. The dissolution of clays is accompanied by the decrease in the layer charge, followed by a decrease in the cation-exchange capacity. The highest TOC values coincide with the highest total elemental concentrations in the leachates, and correspondingly, the highest dissolution degree. However, no quantitative link could be established between the degree of organic matter decomposition and clay dissolution.

  17. Motion-Based pH Sensing Based on the Cartridge-Case-like Micromotor.

    Science.gov (United States)

    Su, Yajun; Ge, Ya; Liu, Limei; Zhang, Lina; Liu, Mei; Sun, Yunyu; Zhang, Hui; Dong, Bin

    2016-02-17

    In this paper, we report a novel cartridge-case-like micromotor. The micromotor, which is fabricated by the template synthesis method, consists of a gelatin shell with platinum nanoparticles decorating its inner surface. Intriguingly, the resulting cartridge-case-like structure exhibits a pH-dependent "open and close" feature, which originates from the pH responsiveness of the gelatin material. On the basis of the catalytic activity of the platinum nanoparticle inside the gelatin shell, the resulting cartridge-case-like structure is capable of moving autonomously in the aqueous solution containing the hydrogen peroxide fuel. More interestingly, we find out that the micromotor can be utilized as a motion-based pH sensor over the whole pH range. The moving velocity of the micromotor increases monotonically with the increase of pH of the analyte solution. Three different factors are considered to be responsible for the proportional relation between the motion speed and pH of the analyte solution: the peroxidase-like and oxidase-like catalytic behavior of the platinum nanoparticle at low and high pH, the volumetric decomposition of the hydrogen peroxide under the basic condition and the pH-dependent catalytic activity of the platinum nanoparticle caused by the swelling/deswelling behavior of the gelatin material. The current work highlights the impact of the material properties on the motion behavior of a micromotor, thus paving the way toward its application in the motion-based sensing field.

  18. pH effect on pit potential and protection potential of stainless steels AISI-304, 310 and 316 in NaCl solution

    International Nuclear Information System (INIS)

    Cabral, U.Q.; Sathler, L.; Mariano Neto, F.

    1973-06-01

    For three austenitic stainless steels, AISI 304, 310 and 316, the pH influence on the rupture, protection and corrosion potentials was studied in a 0,5N NACl solution. The pit potentials determined by the chronogalvonometric method, are pH independent within the acid range. They showed a rough linear variation within the basic range having a maximum corresponding to the pH value of 8.8. The electrochemical hysteresis method, employed for determining the protection potential, presented a total pH independence for the AISI 316. The other steels showed a small dependence within the basic range but with a tendency for the protection potential to become slightly more active with increasing pH, within the acid range. It was also noted for the three steels studied that the corrosion potental became more active with increasing pH, within the basic range [pt

  19. Hydrolysis of R7T7 nuclear waste glass in dilute media: mechanisms and rate as a function of pH

    International Nuclear Information System (INIS)

    Advocat, T.; Vernaz, E.; Charpentier, H.; Crovisier, J.L.; Ehret, G.

    1990-01-01

    R7T7 nuclear waste glass dissolution in highly dilute aqueous media under static conditions at 90 0 C occurs according to two different mechanisms depending on the solution acidity. In acid media (pH 4.8 and 5.5), preferential extraction of glass network modifiers results in the formation of an alkali metal-depleted surface region on which amorphous and crystallized (phosphate) compounds rich in transition elements precipitate. Steady-state dissolution conditions are not reached, as attested by variable normalized Si, B and Na mass losses. Glass dissolution is stoichiometric in basic media (pH 7 to 10): the strong bonds of the silicated network are broken at a rate that increases with the pH: the glass dissolution rate increases by a factor of 15 between pH 7 and 10. Under these conditions, alteration products at the glass/solution interface do not constitute a short-term kinetic barrier against the release of the major glass components

  20. Engineering polyelectrolyte multilayer structure at the nanometer length scale by tuning polymer solution conformation.

    Science.gov (United States)

    Boddohi, Soheil; Killingsworth, Christopher; Kipper, Matt

    2008-03-01

    Chitosan (a weak polycation) and heparin (a strong polyanion) are used to make polyelectrolyte multilayers (PEM). PEM thickness and composition are determined as a function of solution pH (4.6 to 5.8) and ionic strength (0.1 to 0.5 M). Over this range, increasing pH increases the PEM thickness; however, the sensitivity to changes in pH is a strong function of ionic strength. The PEM thickness data are correlated to the polymer conformation in solution. Polyelectrolyte conformation in solution is characterized by gel permeation chromatography (GPC). The highest sensitivity of PEM structure to pH is obtained at intermediate ionic strength. Different interactions govern the conformation and adsorption phenomena at low and high ionic strength, leading to reduced sensitivity to solution pH at extreme ionic strengths. The correspondence between PEM thickness and polymer solution conformation offers opportunities to tune polymer thin film structure at the nanometer length scale by controlling simple, reproducible processing conditions.

  1. Occurrence forms of uranium in the production solutions in the areas of underground leaching of epigenetic uranium deposits

    International Nuclear Information System (INIS)

    Serebrennikov, V.S.; Dorofeeva, V.A.

    1980-01-01

    Redox, acid-basic features of solutions (Eh changes from + 50 to 650 mV, pH from 7.5 to 1.5) and their chemical composition are studied in the process of hydrogeochemical investigations at the areas of underground leaching (UL) of epigenetic uranium deposits. It is shown that at studied areas of UL under neutral and weakly acidic conditions up to (pH 6.0-5.8), carbonate complexes of uranyl are the prevailing form of uranium existence in the solution, and sulfate complexes prevail under more acidic conditions. A supposition is made that it is expedient to process separate ore blocks with increased carbonate contents, particularly with oxidant additions under near-neutral acid-basic conditions (pH 7.2-6.8) with the use of weakly acid pumping solutions, which act (at the expense of their interaction with carbonates of ore-containing rocks) for enrichment of working solutions with HCO 3 - and CO 3 2- ions, promoting uranium transfer into solution

  2. Some effects of pH on iodine volatility in containment

    International Nuclear Information System (INIS)

    Ashmore, C.B.; Gwyther, J.R.; Sims, H.E.

    1994-01-01

    The behaviour of iodine in containment in the event of an accident involving fission product release would be strongly dependent on pH. High pH leads to a lower rate of radiolytic oxidation and in alkaline conditions the thermally stable form is IO 3 - . Much of the work on effects of pH on radiolytic oxidation reported in the literature may be erroneous or misleading because of postirradiation reaction and in this report some new experiments are described which were designed to overcome these problems involving sparged irradiated solutions of CsI spiked with 131 I. The rate of radiolytic oxidation has been measured as a function of pH between pH 4.6 and pH 9 and iodide concentrations between 10 -4 and 10 -6 mol dm -3 . Also discussed in the paper are factors which can affect the pH of the sump water and the effects of high pH in sprays. It is concluded that high pH is beneficial and it is important not only to achieve high pH but to maintain it. (author). 10 refs., 1 tab., 6 figs

  3. Thermodynamic calculations of AuxAg1−x – Fluid equilibria and their applications for ore-forming conditions

    International Nuclear Information System (INIS)

    Liang, Y.; Hoshino, K.

    2015-01-01

    Highlights: • Solubilities of Au–Ag solid solutions are calculated at wide conditions. • Ratios of dissolved Au and Ag depend only on pH at intermediate pH. • Fluid conditions for high gold finenesses have been examined. - Abstract: Concentrations of dissolved gold and silver species in hydrothermal fluids equilibrated with Au–Ag solid solutions have been calculated at wide conditions on the well known fO 2 –pH spaces. Ratios of the total concentrations of dissolved gold and silver species (∑Au/∑Ag) are higher as pH higher and fO 2 lower. The ratios are constant at very low and high pH conditions where major dissolved species of both gold and silver are chloride complexes and thio complexes, respectively, while the ratios practically depend only on pH at intermediate pH conditions where Au(HS) 2 − and AgCl 2 − are major. The calculated results indicate that the solid solutions of high gold finenesses may precipitate from the fluids of low ratios of the total concentrations of dissolved gold and silver species when the conditions are (1) low pH’s and/or (2) high concentration ratios of dissolved chlorine and sulfur and/or (3) high temperatures

  4. Microneedle pH Sensor: Direct, Label-Free, Real-Time Detection of Cerebrospinal Fluid and Bladder pH.

    Science.gov (United States)

    Mani, Ganesh Kumar; Miyakoda, Kousei; Saito, Asuka; Yasoda, Yutaka; Kajiwara, Kagemasa; Kimura, Minoru; Tsuchiya, Kazuyoshi

    2017-07-05

    Acid-base homeostasis (body pH) inside the body is precisely controlled by the kidneys and lungs and buffer systems, such that even a minor pH change could severely affect many organs. Blood and urine pH tests are common in day-to-day clinical trials and require little effort for diagnosis. There is always a great demand for in vivo testing to understand more about body metabolism and to provide effective diagnosis and therapy. In this article, we report the simple fabrication of microneedle-based direct, label-free, and real-time pH sensors. The reference and working electrodes were Ag/AgCl thick films and ZnO thin films on tungsten (W) microneedles, respectively. The morphological and structural characteristics of microneedles were carefully investigated through various analytical methods. The developed sensor exhibited a Nernstian response of -46 mV/pH. Different conditions were used to test the sensor to confirm their accuracy and stability, such as various buffer solutions, with respect to time, and we compared the reading with commercial pH electrodes. Besides that, the fabricated microneedle sensor ability is proven by in vivo testing in mouse cerebrospinal fluid (CSF) and bladders. The pH sensor procedure reported here is totally reversible, and results were reproducible after several rounds of testing.

  5. ph Sensitive hydrogel as colon specific drug delivery

    International Nuclear Information System (INIS)

    Alarifi, A.S.

    2011-01-01

    γ-radiation induced graft copolymerization and crosslinking was for the synthesis of ph-sensitive hydrogels composed of poly (vinyl pyrrolidone) acrylic acid. The prepared hydrogels were subjected to swelling test to evaluate the effects of ph and ionic strength of the surrounding solution. Drastic changes in the swelling parameters where observed by changing the surrounding solution ph values. The release of ibuprofen from hydrogels was monitored as a function of time at ph 1 and ph 7 in order to evaluate the prepared copolymer ability for colon- specific drug carrier uses.

  6. Effect of pH change on the primary uran-mica mineralization

    Energy Technology Data Exchange (ETDEWEB)

    Shmariovich, E M; Zhil' tsova, I G; Pakul' nis, G V; Shugina, G A [Ministerstvo Geologii SSR, Moscow

    1982-01-01

    Conditions of the formation of ore bodies of hexavalent uranium minerals represented by uranyl vanadates and phosphates which are primary and sedimented from low temperature solutions (carnotite deposits in calcretes and carnotite - autunite deposits in black shale formations) are considered. Thermodynamic curves of the solubility dependence of various uranyl minerals on pH medium in the absence of SO/sub 4//sup 2 -/ and CO/sub 3//sup 2 -/ ions and for sulphate-carbonate solutions have been calculated using dissociation constants of corresponding acids and ..delta..G/sup 0/f(298.15) values. It has been ascertained that uranyl mineral compounds according to the dependence of their solubility on ph medium form a distinct series from molybdates through arsenates, phosphates, vanadates and silicates to minerals of uranophane and kasolite group. It is shown that during the formation of infiltration deposits with uranyl mineralization a decisive role is played by the contrast change of pH value of medium caused by the presence of acid geochemical barrier (uranyl molybdates, arsenates, phosphates and vanadates are precipitating) or neutralizing alkaline barriers (uran-mica and uranyl silicates are precipitating) on the path of movement of oxygen metal-bearing solutions.

  7. Corrosion of zirconium alloys in alternating pH environment

    International Nuclear Information System (INIS)

    Mayer, P.; Manolescu, A.V.

    1985-01-01

    Behaviour of two commercial alloys, Zircaloy-2 and zirconium-2.5 wt% niobium were investigated in an environment of alternating pH. Corrosion advancement and scale morphology of coupons exposed to aqueous solution of LiOH (pH 10.2 and 14) were followed as a function of temperature (300-360 degreesC) and time (up to 165 days). The test sequence consisted of short term exposure to high pH and re-exposure to low pH solutions for extended period of time followed by a short term test in high pH. The results of these tests and detailed post-corrosion analysis indicate a fundamental difference between the corrosion behaviour of these two materials. Both alloys corrode fast in high pH environments, but only zirconium-2.5 wt% niobium continues to form detectable new oxide in low pH solution

  8. A new slurry pH model accounting for effects of ammonia and carbon dioxide volatilization on solution speciation

    DEFF Research Database (Denmark)

    Petersen, V.; Markfoged, R.; Hafner, S. D.

    2014-01-01

    a reduced variable that combines time and location and an analytical approach to solving the resulting system of equations using Mathematica. To evaluate the model, we made measurements of pH at a resolution of 0.1 mm in the top 30 mm of an ammonium bicarbonate solution. These measurements show the creation...

  9. The Semen pH Affects Sperm Motility and Capacitation.

    Science.gov (United States)

    Zhou, Ji; Chen, Li; Li, Jie; Li, Hongjun; Hong, Zhiwei; Xie, Min; Chen, Shengrong; Yao, Bing

    2015-01-01

    As the chemical environment of semen can have a profound effect on sperm quality, we examined the effect of pH on the motility, viability and capacitation of human sperm. The sperm in this study was collected from healthy males to avoid interference from other factors. The spermatozoa cultured in sperm nutrition solution at pH 5.2, 6.2, 7.2 and 8.2 were analyzed for sperm total motility, progressive motility (PR), hypo-osmotic swelling (HOS) rate, and sperm penetration. Our results showed that these parameters were similar in pH 7.2 and 8.2 sperm nutrition solutions, but decreased in pH 5.2 and 6.2 solutions. The HOS rate exhibited positive correlation with the sperm total motility and PR. In addition, the sperm Na(+)/K(+)-ATPase activity at different pHs was measured, and the enzyme activity was significantly lower in pH 5.2 and 6.2 media, comparing with that in pH 8.2 and pH 7.2 solutions. Using flow cytometry (FCM) and laser confocal scanning microscopy (LCSM) analysis, the intracellular Ca2(+ )concentrations of sperm cultured in sperm capacitation solution at pH 5.2, 6.2, 7.2 and 8.2 were determined. Compared with that at pH 7.2, the mean fluorescence intensity of sperm in pH 5.2 and 6.2 media decreased significantly, while that of pH 8.2 group showed no difference. Our results suggested that the declined Na(+)/K(+)-ATPase activity at acidic pHs result in decreased sperm movement and capacitation, which could be one of the mechanisms of male infertility.

  10. Enzymatic characterization of peptidic materials isolated from aqueous solutions of ammonium cyanide (pH 9) and hydrocyanic acid (pH 6) exposed to ionizing radiation.

    Science.gov (United States)

    Niketic, V; Draganić, Z; Nesković, S; Draganić, I

    1982-01-01

    The enzymatic digestion of some radiolytically produced peptidic materials was examined. The substrates were compounds isolated from 0.1 molar solutions of NH4CN (pH 9) and HCN (pH 6), after their exposure to gamma rays from a 60Co source (15-20 Mrad doses). Commercial proteolytic enzymes pronase and aminopeptidase M were used. The examined materials were of composite nature and proteolytic action was systematically observed after their subsequent purification. In some fractions the effect was found to be positive with up to 30% of peptide bonds cleaved with respect to the amino acid content. These findings support our previous conclusions on the free radical induced formation of peptidic backbones without the intervention of amino acids. Some side effects were also noted which might be of interest in observations on enzymatic cleavage of other composite peptidic materials of abiotic origin.

  11. Removal of mercury ion from aqueous solution by activated carbons obtained from biomass and coals

    Energy Technology Data Exchange (ETDEWEB)

    Ekinci, E.; Yardim, F. [Faculty of Chemical Engineering, Istanbul Technical University, Ayazaga, 80626 Istanbul (Turkey); Budinova, T.; Petrov, N.; Razvigorova, M.; Minkova, V. [Institute of Organic Chemistry, Bulgarian Academy of Sciences, Acad.G.Bonchev, str. bl. 9, Sofia (Bulgaria)

    2002-06-20

    The adsorption of Hg(II) from aqueous solution at 293 K by activated carbons obtained from apricot stones, furfural and coals was studied. Adsorption studies were performed under the varying conditions of time of treatment, metal ion concentration and pH. The process of adsorption followed Langmuir isotherm. The removal of Hg(II) increased with the increase of pH of the solution from 2 to 5 and remained constant up to pH 10. Desorption studies were preformed.

  12. Modeling of acetate-type fermentation of sugar-containing wastewater under acidic pH conditions.

    Science.gov (United States)

    Huang, Liang; Pan, Xin-Rong; Wang, Ya-Zhou; Li, Chen-Xuan; Chen, Chang-Bin; Zhao, Quan-Bao; Mu, Yang; Yu, Han-Qing; Li, Wen-Wei

    2018-01-01

    In this study, a kinetic model was developed based on Anaerobic Digestion Model No. 1 to provide insights into the directed production of acetate and methane from sugar-containing wastewater under low pH conditions. The model sufficiently described the dynamics of liquid-phase and gaseous products in an anaerobic membrane bioreactor by comprehensively considering the syntrophic bioconversion steps of sucrose hydrolysis, acidogenesis, acetogenesis and methanogenesis under acidic pH conditions. The modeling results revealed a significant pH-dependency of hydrogenotrophic methanogenesis and ethanol-producing processes that govern the sucrose fermentative pathway through changing the hydrogen yield. The reaction thermodynamics of such acetate-type fermentation were evaluated, and the implications for process optimization by adjusting the hydraulic retention time were discussed. This work sheds light on the acid-stimulated acetate-type fermentation process and may lay a foundation for optimization of resource-oriented processes for treatment of food wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Degradation of amoxicillin, ampicillin and cloxacillin antibiotics in aqueous solution by the UV/ZnO photocatalytic process

    International Nuclear Information System (INIS)

    Elmolla, Emad S.; Chaudhuri, Malay

    2010-01-01

    The study examined the effect of operating conditions (zinc oxide concentration, pH and irradiation time) of the UV/ZnO photocatalytic process on degradation of amoxicillin, ampicillin and cloxacillin in aqueous solution. pH has a great effect on amoxicillin, ampicillin and cloxacillin degradation. The optimum operating conditions for complete degradation of antibiotics in an aqueous solution containing 104, 105 and 103 mg/L amoxicillin, ampicillin and cloxacillin, respectively were: zinc oxide 0.5 g/L, irradiation time 180 min and pH 11. Under optimum operating conditions, complete degradation of amoxicillin, ampicillin and cloxacillin occurred and COD and DOC removal were 23.9 and 9.7%, respectively. The photocatalytic reactions under optimum conditions approximately followed a pseudo-first order kinetics with rate constant (k) 0.018, 0.015 and 0.029 min -1 for amoxicillin, ampicillin and cloxacillin, respectively. UV/ZnO photocatalysis can be used for amoxicillin, ampicillin and cloxacillin degradation in aqueous solution.

  14. Effects of EDTA on the electronic properties of passive film formed on Fe-20Cr in pH 8.5 buffer solution

    International Nuclear Information System (INIS)

    Cho, Eun Ae; Kwon, Hyuk Sang; Beranrd, Frederic

    2003-01-01

    The electronic properties of the passive film formed on Fe-20Cr ferritic stainless steel in pH 8.5 buffer solution containing 0.05 M EDTA (ethylene diammine tetraacetic acid) were examined by the photocurrent measurements and Mott-Schottky analysis for the film. XPS depth profile for the film demonstrated that Cr content in the outermost layer of the passive film was higher in the solution with EDTA than that in the solution without EDTA, due to selective dissolution of Fe by EDTA. In the solution with EDTA, the passive film showed characteristics of an amorphous or highly disordered n-type semiconductor. The band gap energies of the passive film are estimated to be ∼ 3.0 eV, irrespective of film formation potential from 0 to 700 mV SCE and of presence of EDTA. However, the donor density of the passive film formed in the solution with EDTA is much higher than that formed in the solution without EDTA, due to an increase in oxygen vacancy resulted from the dissolution of Fe-oxide in the outermost layer of the passive film. These results support the proposed model that the passive film formed on Fe-20Cr in pH 8.5 buffer solution mainly consists of Cr-substituted γ-Fe 2 O 3

  15. Stress corrosion cracking properties of 15-5PH steel

    Science.gov (United States)

    Rosa, Ferdinand

    1993-01-01

    Unexpected occurrence of failures, due to stress corrosion cracking (SCC) of structural components, indicate a need for improved characterization of materials and more advanced analytical procedures for reliably predicting structures performance. Accordingly, the purpose of this study was to determine the stress corrosion susceptibility of 15-5PH steel over a wide range of applied strain rates in a highly corrosive environment. The selected environment for this investigation was a highly acidified sodium chloride (NaCl) aqueous solution. The selected alloy for the study was a 15-5PH steel in the H900 condition. The slow strain rate technique was selected to test the metals specimens.

  16. Removal of radiocobalt from aqueous solutions by kaolinite affected by solid content, pH, ionic strength, contact time and temperature

    International Nuclear Information System (INIS)

    Kan Li; Zhengjie Liu; Lei Chen; Yunhui Dong; Jun Hu; Chinese Academy of Sciences, Hefei

    2013-01-01

    The kaolinite sample was characterized by Fourier transform infrared spectroscopy (FT-IR) and X-ray powder diffraction, and was applied as adsorbent for the removal of radiocobalt ions from radioactive wastewater. The results demonstrated that the sorption of Co(II) was strongly dependent on pH and ionic strength at low pH values, and independent of pH and ionic strength at high pH values. The sorption of Co(II) was dominated by outer-sphere surface complexation or ion exchange at low pH values, whereas inner-sphere surface complexation was the main sorption mechanism at high pH values. The sorption isotherms were well described by Langmuir, Freundlich and Dubinin-Radushkevich models. The thermodynamic parameters (i.e., ΔGdeg, ΔSdeg, ΔHdeg) calculated from the temperature-dependent sorption isotherms indicated that the sorption of Co(II) on kaolinite was an endothermic and spontaneous process. The results of high sorption capacity of kaolinite suggested that the kaolinite sample was a suitable material for the preconcentration of Co(II) from large volumes of aqueous solutions and as backfill materials in nuclear waste management. (author)

  17. A method for measuring pH at high temperatures is presented

    International Nuclear Information System (INIS)

    Chaudon, Luc.

    1979-01-01

    Two hydrogen electrodes are used and set up in a PTFE cell comprising two chambers connected through a saturated potassium chloride solution bridge. This cell is put in an autoclave containing hydrogen. The potential difference of the following cell is measured: H 2 , Pt, R solution - KCl saturated solution at 25 0 C - X solution, Pt, H 2 - The pH of the reference solution R is known up to 300 0 C and the X solution must have its pH to be determined. The precision of the measures at 300 0 C is estimated about +-0,1 pH unit. The dissociation constant of water is calculated from pH variations of alcaline solutions up to 300 0 C. The method has helped to measure the pH at 300 0 C of some boric acid solutions, with or without lithium hydroxide additions, in the following concentration range: B: 250 to 1500 ppm and Li: 0 to 3 ppm. Some concentrations are in fact those chosen for the primary circuits of pressurized water reactors. The pH of ammoniacal solutions is measured too and helped to determine the variations of the dissociation constant of ammonia with temperature [fr

  18. Complexing Agents and pH Influence on Chemical Durability of Type I Molded Glass Containers.

    Science.gov (United States)

    Biavati, Alberto; Poncini, Michele; Ferrarini, Arianna; Favaro, Nicola; Scarpa, Martina; Vallotto, Marta

    2017-01-01

    Among the factors that affect the glass surface chemical durability, pH and complexing agents present in aqueous solution have the main role. Glass surface attack can be also related to the delamination issue causing glass particles' appearance in the pharmaceutical preparation. A few methods to check for glass containers delamination propensity and some control guidelines have been proposed. The present study emphasizes the possible synergy between a few complexing agents with pH on borosilicate glass chemical durability.Hydrolytic attack was performed in small-volume 23 mL type I glass containers autoclaved according to the European Pharmacopoeia or United States Pharmacopeia for 1 h at 121 °C, in order to enhance the chemical attack due to time, temperature, and the unfavorable surface/volume ratio. Solutions of 0.048 M or 0.024 M (M/L) of the acids citric, glutaric, acetic, EDTA (ethylenediaminetetraacetic acid), together with sodium phosphate with water for comparison, were used for the trials. The pH was adjusted ±0.05 units at fixed values 5.5, 6.6, 7, 7.4, 8, and 9 by LiOH diluted solution.Because silicon is the main glass network former, silicon release into the attack solutions was chosen as the main index of the glass surface attack and analysed by inductively coupled plasma atomic emission spectrophotometry. The work was completed by the analysis of the silicon release in the worst attack conditions of molded glass, soda lime type II glass, and tubing borosilicate glass vials to compare different glass compositions and forming technologies. Surface analysis by scanning electron microscopy was finally performed to check for the surface status after the worst chemical attack condition by citric acid. LAY ABSTRACT: Glass, like every packaging material, can have some usage limits, mainly in basic pH solutions. The issue of glass surface degradation particles that appear in vials (delamination) has forced a number of drug product recalls in recent years

  19. Chemical behaviour of plutonium in aqueous chloride solutions

    International Nuclear Information System (INIS)

    Bueppelmann, K.; Kim, J.I.

    1988-06-01

    The chemical behaviour of Plutonium has been investigated in concentrated NaCl solutions in the neutral pH range. The α-radiation induced radiolysis reactions oxidize the Cl - -ion to Cl 2 , HClO, ClO - and other species, which produce a strongly oxidizing medium. Under these conditions the Pu ions of lower oxidation states are readily oxidized to Pu(VI), which then undergo depending on the pH of the solution, various chemical reactions to produce PuO 2 Cl n , PuO 2 (ClO) m or PuO 2 (OH) x species. In addition to primary radiolysis reactions taking place in NaCl solutions, the reactions leading to the PuO 2 (Cl) n and PuO 2 (ClO) m species have been characterized and quantified systematically by spectroscopic and thermodynamic evaluation. The redox and complexation reactions of Pu ions under varying NaCl concentration, specific α-activity and pH are discussed. (orig.) [de

  20. Effects of sodium hypochlorite and high pH buffer solution in electrokinetic soil treatment on soil chromium removal and the functional diversity of soil microbial community

    International Nuclear Information System (INIS)

    Cang Long; Zhou Dongmei; Alshawabkeh, Akram N.; Chen Haifeng

    2007-01-01

    Effects of sodium hypochlorite (NaClO), applied as an oxidant in catholyte, and high pH buffer solution on soil Cr removal and the functional diversity of soil microbial community during enhanced electrokinetic treatments of a chromium (Cr) contaminated red soil are evaluated. Using pH control system to maintain high alkalinity of soil together with the use of NaClO increased the electrical conductivities of soil pore liquid and electroosmotic flux compared with the control (Exp-01). The pH control and NaClO improved the removal of Cr(VI) and total Cr from the soil. The highest removal percentages of soil Cr(VI) and total Cr were 96 and 72%, respectively, in Exp-04 when the pH value of the anolyte was controlled at 10 and NaClO was added in the catholyte. The alkaline soil environment and introduction of NaClO in the soil enhanced the desorption of Cr(VI) from the soil and promoted Cr(III) oxidation to mobile Cr(VI), respectively. However, the elevated pH and introduction of NaClO in the soil, which are necessary for improving the removal efficiency of soil Cr, resulted in a significantly adverse impact on the functional diversity of soil microbial community. It suggests that to assess the negative impact of extreme conditions for enhancing the extraction efficiencies of Cr on the soil properties and function is necessary

  1. Improved fluorescent labeling of chitin oligomers: Chitinolytic properties of acidic mammalian chitinase under somatic tissue pH conditions.

    Science.gov (United States)

    Wakita, Satoshi; Kimura, Masahiro; Kato, Naoki; Kashimura, Akinori; Kobayashi, Shunsuke; Kanayama, Naoto; Ohno, Misa; Honda, Shotaro; Sakaguchi, Masayoshi; Sugahara, Yasusato; Bauer, Peter O; Oyama, Fumitaka

    2017-05-15

    Acidic mammalian chitinase (AMCase) has been implicated in various pathophysiological conditions including asthma, allergic inflammation and food processing. AMCase is most active at pH 2.0, and its activity gradually decreases to up to pH 8. Here we analyzed chitin degradation by AMCase in weak acidic to neutral conditions by fluorophore-assisted carbohydrate electrophoresis established originally for oligosaccharides analysis. We found that specific fragments with slower-than-expected mobility as defined by chitin oligosaccharide markers were generated at pH 5.0∼8.0 as by-products of the reaction. We established an improved method for chitin oligosaccharides suppressing this side reaction by pre-acidification of the fluorophore-labeling reaction mixture. Our improved method specifically detects chitin oligosaccharides and warrants quantification of up to 50nmol of the material. Using this strategy, we found that AMCase produced dimer of N-acetyl-d-glucosamine (GlcNAc) at strong acidic to neutral condition. Moreover, we found that AMCase generates (GlcNAc) 2 as well as (GlcNAc) 3 under physiological conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Reorganization of the 3D matrix of polyelectrolytes complexes of chitosan/chondroitin sulfate swollen in different conditions of pH and immersion time

    International Nuclear Information System (INIS)

    Fajardo, Andre R.; Piai, Juliana F.; Rubira, Adley F.; Muniz, Edvani C.

    2009-01-01

    The chitosan (CT), a polysaccharide that has excellent properties for use as biomaterials, shows cationic nature and properties of high charge density in acidic solutions, thus CT can form complex polyelectrolyte (PEC) with polyanionic moieties such as the chondroitin sulfate (CS), a key component of cartilage matrix. We studied the reorganization of chains on 3D matrix of CT/CS PEC at swollen state in different conditions of pH and immersion time. It was verified that this PEC (QT/CS) has the capacity to reorganize its 3D matrix but it depends of the pH of the medium in which it is swelled and the time that remains immersed. The reorganization of the 3D matrix is caused by the reordering of the chains forming the PEC after the release of the CS, that occurs mainly at pH values higher than or close to the pKa of CT (pKa CT) . Such reorganization was detected by X-ray diffraction profiles and allows an increase in crystallinity, thermal stability and pore size of the PEC. This shows that the PEC produced can be processed to suit its use as bio material, applied i.e. as drugs release devices. (author)

  3. Reorganization of the 3D matrix of polyelectrolytes complexes of chitosan/chondroitin sulfate swollen in different conditions of pH and immersion time

    Energy Technology Data Exchange (ETDEWEB)

    Fajardo, Andre R.; Piai, Juliana F.; Rubira, Adley F.; Muniz, Edvani C., E-mail: ecmuniz@uem.b [Universidade Estadual de Maringa (DG/UEM), PR (Brazil). Dept. de Quimica. Grupo de Materiais Polimericos e Compositos

    2009-07-01

    The chitosan (CT), a polysaccharide that has excellent properties for use as biomaterials, shows cationic nature and properties of high charge density in acidic solutions, thus CT can form complex polyelectrolyte (PEC) with polyanionic moieties such as the chondroitin sulfate (CS), a key component of cartilage matrix. We studied the reorganization of chains on 3D matrix of CT/CS PEC at swollen state in different conditions of pH and immersion time. It was verified that this PEC (QT/CS) has the capacity to reorganize its 3D matrix but it depends of the pH of the medium in which it is swelled and the time that remains immersed. The reorganization of the 3D matrix is caused by the reordering of the chains forming the PEC after the release of the CS, that occurs mainly at pH values higher than or close to the pKa of CT (pKa CT) . Such reorganization was detected by X-ray diffraction profiles and allows an increase in crystallinity, thermal stability and pore size of the PEC. This shows that the PEC produced can be processed to suit its use as bio material, applied i.e. as drugs release devices. (author)

  4. Regulating NETosis: Increasing pH Promotes NADPH Oxidase-Dependent NETosis

    Science.gov (United States)

    Khan, Meraj A.; Philip, Lijy M.; Cheung, Guillaume; Vadakepeedika, Shawn; Grasemann, Hartmut; Sweezey, Neil; Palaniyar, Nades

    2018-01-01

    Neutrophils migrating from the blood (pH 7.35–7.45) into the surrounding tissues encounter changes in extracellular pH (pHe) conditions. Upon activation of NADPH oxidase 2 (Nox), neutrophils generate large amounts of H+ ions reducing the intracellular pH (pHi). Nevertheless, how extracellular pH regulates neutrophil extracellular trap (NET) formation (NETosis) is not clearly established. We hypothesized that increasing pH increases Nox-mediated production of reactive oxygen species (ROS) and neutrophil protease activity, stimulating NETosis. Here, we found that raising pHe (ranging from 6.6 to 7.8; every 0.2 units) increased pHi of both activated and resting neutrophils within 10–20 min (Seminaphtharhodafluor dual fluorescence measurements). Since Nox activity generates H+ ions, pHi is lower in neutrophils that are activated compared to resting. We also found that higher pH stimulated Nox-dependent ROS production (R123 generation; flow cytometry, plate reader assay, and imaging) during spontaneous and phorbol myristate acetate-induced NETosis (Sytox Green assays, immunoconfocal microscopy, and quantifying NETs). In neutrophils that are activated and not resting, higher pH stimulated histone H4 cleavage (Western blots) and NETosis. Raising pH increased Escherichia coli lipopolysaccharide-, Pseudomonas aeruginosa (Gram-negative)-, and Staphylococcus aureus (Gram-positive)-induced NETosis. Thus, higher pHe promoted Nox-dependent ROS production, protease activity, and NETosis; lower pH has the opposite effect. These studies provided mechanistic steps of pHe-mediated regulation of Nox-dependent NETosis. Raising pH either by sodium bicarbonate or Tris base (clinically known as Tris hydroxymethyl aminomethane, tromethamine, or THAM) increases NETosis. Each Tris molecule can bind 3H+ ions, whereas each bicarbonate HCO3− ion binds 1H+ ion. Therefore, the amount of Tris solution required to cause the same increase in pH level is less than that of equimolar

  5. Regulating NETosis: Increasing pH Promotes NADPH Oxidase-Dependent NETosis

    Directory of Open Access Journals (Sweden)

    Meraj A. Khan

    2018-02-01

    Full Text Available Neutrophils migrating from the blood (pH 7.35–7.45 into the surrounding tissues encounter changes in extracellular pH (pHe conditions. Upon activation of NADPH oxidase 2 (Nox, neutrophils generate large amounts of H+ ions reducing the intracellular pH (pHi. Nevertheless, how extracellular pH regulates neutrophil extracellular trap (NET formation (NETosis is not clearly established. We hypothesized that increasing pH increases Nox-mediated production of reactive oxygen species (ROS and neutrophil protease activity, stimulating NETosis. Here, we found that raising pHe (ranging from 6.6 to 7.8; every 0.2 units increased pHi of both activated and resting neutrophils within 10–20 min (Seminaphtharhodafluor dual fluorescence measurements. Since Nox activity generates H+ ions, pHi is lower in neutrophils that are activated compared to resting. We also found that higher pH stimulated Nox-dependent ROS production (R123 generation; flow cytometry, plate reader assay, and imaging during spontaneous and phorbol myristate acetate-induced NETosis (Sytox Green assays, immunoconfocal microscopy, and quantifying NETs. In neutrophils that are activated and not resting, higher pH stimulated histone H4 cleavage (Western blots and NETosis. Raising pH increased Escherichia coli lipopolysaccharide-, Pseudomonas aeruginosa (Gram-negative-, and Staphylococcus aureus (Gram-positive-induced NETosis. Thus, higher pHe promoted Nox-dependent ROS production, protease activity, and NETosis; lower pH has the opposite effect. These studies provided mechanistic steps of pHe-mediated regulation of Nox-dependent NETosis. Raising pH either by sodium bicarbonate or Tris base (clinically known as Tris hydroxymethyl aminomethane, tromethamine, or THAM increases NETosis. Each Tris molecule can bind 3H+ ions, whereas each bicarbonate HCO3− ion binds 1H+ ion. Therefore, the amount of Tris solution required to cause the same increase in pH level is less than that of equimolar

  6. Effects of Iodide and Hydrogen Peroxide on Measuring High Temperature pH in Various Lithium Borate Buffer Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Sik; Yun, Myung Hee; Yeon, Jei Won; Song, Kyu Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-10-15

    In a reactor coolant system of nuclear power plants, the need for reliable high temperature pH electrodes has resulted from interests in the corrosion and corrosion product behaviors of the structural materials in a high temperature coolant system. In developing the electrodes for measuring the high temperature pH of aqueous solutions, it is necessary to note two major problems: the chemical stability of an electrode against other chemical impurities, and an electrode's integrity as the temperature and pressure are varied between operational extremes. Over the past decade Macdonald et al. and Danielson et al. have developed many ceramic membrane pH electrodes based on a yttrium stabilized zirconium oxide. However, there are still many experimental difficulties associated with the problems in obtaining electrochemical information across different pressure boundaries and against many kinds of chemical impurities caused by the radiolysis of water and the leakage of a fuel clad. In the present work, we investigated the effects of the environmental factors on a high temperature pH. The selected environmental factors are as follows: system pressure, and chemical species such as iodide and hydrogen peroxide ions.

  7. Measurements of spectral responses for developing fiber-optic pH sensor

    Science.gov (United States)

    Yoo, Wook Jae; Heo, Ji Yeon; Jang, Kyoung Won; Seo, Jeong Ki; Moon, Jin Soo; Park, Jang-Yeon; Park, Byung Gi; Cho, Seunghyun; Lee, Bongsoo

    2011-01-01

    In this study, we have fabricated a fiber-optic pH sensor, which is composed of a light source, a pH-sensing probe, plastic optical fibers and a spectrometer, for determining the degree of infection by Helicobacter pylori in the stomach. As pH indicators, phenol red and m-cresol purple are used, and pH liquid solutions are prepared by mixing phenol red or m-cresol purple solutions and various kinds of pH buffer solutions. The light emitted by a light source is guided by plastic optical fibers to the pH liquid solution, and the optical characteristic of a reflected light is changed according to the color variations of the pH indicator in the pH-sensing probe. Therefore, we have measured the intensities and wavelength shifts of the reflected lights, which change according to the color variations of indicators at different pH values, by using a spectrometer for spectral analysis. Also, the relationships between the pH values of liquid solutions and the optical properties of the modulated lights are obtained on the basis of the changes of the colors of indicators.

  8. Solution to random differential equations with boundary conditions

    Directory of Open Access Journals (Sweden)

    Fairouz Tchier

    2017-04-01

    Full Text Available We study a family of random differential equations with boundary conditions. Using a random fixed point theorem, we prove an existence theorem that yields a unique random solution.

  9. The nature of rusts and corrosion characteristics of low alloy and plain carbon steels in three kinds of concrete pore solution with salinity and different pH

    International Nuclear Information System (INIS)

    Singh, J.K.; Singh, D.D.N.

    2012-01-01

    Highlights: ► LAS rebars corrode 2–3 times slower than PCS in concrete pore solution and mortars. ► Raman and XRD studies show that goethite and maghemite phases of rusts formed on LAS. ► On PCS unstable phases of lepidocrocite and akaganite are formed. ► EIS confirms more stable rust on LAS than on PCS. ► A model is proposed to explain formation of passive film on surface of steels. - Abstract: Correlation of corrosion characteristics and nature of rusts on low alloy (LA) and plain carbon (PC) steels exposed in simulated concrete pore solution of different pH is studied. Rusts formed under wet/dry conditions are examined by Raman spectroscopy and X-ray diffraction. LA rust is more adherent compared to PC as confirmed by measurement of weight in gain and electrochemical studies. EIS results show improvement in protective properties of steels with passage of time. Both steels are found prone to pitting attack in chloride contaminated pore solution. Rebars embedded in concrete exhibit same trend as recorded in solution exposure tests.

  10. The analytical solution for drug delivery system with nonhomogeneous moving boundary condition

    Science.gov (United States)

    Saudi, Muhamad Hakimi; Mahali, Shalela Mohd; Harun, Fatimah Noor

    2017-08-01

    This paper discusses the development and the analytical solution of a mathematical model based on drug release system from a swelling delivery device. The mathematical model is represented by a one-dimensional advection-diffusion equation with nonhomogeneous moving boundary condition. The solution procedures consist of three major steps. Firstly, the application of steady state solution method, which is used to transform the nonhomogeneous moving boundary condition to homogeneous boundary condition. Secondly, the application of the Landau transformation technique that gives a significant impact in removing the advection term in the system of equation and transforming the moving boundary condition to a fixed boundary condition. Thirdly, the used of separation of variables method to find the analytical solution for the resulted initial boundary value problem. The results show that the swelling rate of delivery device and drug release rate is influenced by value of growth factor r.

  11. Evaluation method of iodine re-evolution from an in-containment water pool after a loss of coolant accident, Part I: pH estimation of a solution with various chemicals

    International Nuclear Information System (INIS)

    Kim, Tae Hyeon; Jeong, Ji Hwan

    2016-01-01

    Highlights: • It is required to evaluate re-evolved iodine from sump water after LOCA. • pH evaluation based on Gibbs free energy minimization. • Program was developed to evaluate chemical equilibrium and pH solutions. • Predictions are in good agreement with experimental data. - Abstract: Radioactive iodine, which is released into the atmosphere of the containment building, is absorbed into the containment spray water and dissolved to be ionized. This iodine-rich water is then transported to the in-containment refueling water storage tank (IRWST) in APR1400 nuclear power plants. When the pH of the water is below 7, the dissolved iodine converts to molecular iodine and re-evolves from the water and returns to the atmosphere. A series of studies have been conducted in order to evaluate the iodine re-evolution from the IRWST. This study consists of two parts: the pH evaluation method and the evaluation of the iodine re-evolution. This paper presents the first part, i.e. the pH evaluation method. The equilibrium concentrations of various chemicals in a solution are determined at the minimum Gibbs’ free energy. This method is useful for complex reactant problems rather than equilibrium constants method because the latter method requires numerous equilibrium constants and there might be missing equilibrium constants associated with the solution. The calculated pH values of solutions are compared with the experimental measurements in order to validate this method and the thermodynamic data of the chemicals incorporated into the program. The estimated values for solutions are in good agreement with the experimental measurements within a difference of less than 3.3%.

  12. Ion release from magnesium materials in physiological solutions under different oxygen tensions.

    Science.gov (United States)

    Feyerabend, Frank; Drücker, Heiko; Laipple, Daniel; Vogt, Carla; Stekker, Michael; Hort, Norbert; Willumeit, Regine

    2012-01-01

    Although magnesium as degradable biomaterial already showed clinical proof of concepts, the design of new alloys requires predictive in vitro methods, which are still lacking. Incubation under cell culture conditions to obtain "physiological" corrosion may be a solution. The aim of this study was to analyse the influence of different solutions, addition of proteins and of oxygen availability on the corrosion of different magnesium materials (pure Mg, WE43, and E11) with different surface finishing. Oxygen content in solution, pH, osmolality and ion release were determined. Corrosion led to a reduction of oxygen in solution. The influence of oxygen on pH was enhanced by proteins, while osmolality was not influenced. Magnesium ion release was solution-dependent and enhanced in the initial phase by proteins with delayed release of alloying elements. The main corrosion product formed was magnesium carbonate. Therefore, cell culture conditions are proposed as first step toward physiological corrosion.

  13. Explicit solution for a wave equation with nonlocal condition

    Science.gov (United States)

    Bazhlekova, Emilia; Dimovski, Ivan

    2012-11-01

    An initial-boundary value problem with a nonlocal boundary condition for one-dimensional wave equation is studied. Applying spectral projections, we find a series solution of the problem. The character of the solution found shows that the oscillation amplitude of the system described by this equation increases with time at any fixed x in absence of external forces. To find a representation of the solution more convenient for numerical calculation we develop a two-dimensional operational calculus for the problem. The solution is expressed as a sum of non-classical convolution products of particular solutions and the arbitrary initial functions. This result is an extension of the classical Duhamel principle for the space variable. The representation is used successfully for numerical computation and visualization of the solution. Numerical results obtained for specific test problems with known exact solutions indicate that the present technique provides accurate numerical solutions.

  14. A new equilibrium torus solution and GRMHD initial conditions

    Science.gov (United States)

    Penna, Robert F.; Kulkarni, Akshay; Narayan, Ramesh

    2013-11-01

    Context. General relativistic magnetohydrodynamic (GRMHD) simulations are providing influential models for black hole spin measurements, gamma ray bursts, and supermassive black hole feedback. Many of these simulations use the same initial condition: a rotating torus of fluid in hydrostatic equilibrium. A persistent concern is that simulation results sometimes depend on arbitrary features of the initial torus. For example, the Bernoulli parameter (which is related to outflows), appears to be controlled by the Bernoulli parameter of the initial torus. Aims: In this paper, we give a new equilibrium torus solution and describe two applications for the future. First, it can be used as a more physical initial condition for GRMHD simulations than earlier torus solutions. Second, it can be used in conjunction with earlier torus solutions to isolate the simulation results that depend on initial conditions. Methods: We assume axisymmetry, an ideal gas equation of state, constant entropy, and ignore self-gravity. We fix an angular momentum distribution and solve the relativistic Euler equations in the Kerr metric. Results: The Bernoulli parameter, rotation rate, and geometrical thickness of the torus can be adjusted independently. Our torus tends to be more bound and have a larger radial extent than earlier torus solutions. Conclusions: While this paper was in preparation, several GRMHD simulations appeared based on our equilibrium torus. We believe it will continue to provide a more realistic starting point for future simulations.

  15. Nanofiltration of Mine Water: Impact of Feed pH and Membrane Charge on Resource Recovery and Water Discharge

    Directory of Open Access Journals (Sweden)

    Mark Mullett

    2014-03-01

    Full Text Available Two nanofiltration membranes, a Dow NF 270 polyamide thin film and a TriSep TS 80 polyamide thin film, were investigated for their retention of ionic species when filtering mine influenced water streams at a range of acidic pH values. The functional iso-electric point of the membranes, characterized by changes in retention over a small pH range, were examined by filtering solutions of sodium sulphate. Both membranes showed changes in retention at pH 3, suggesting a zero net charge on the membranes at this pH. Copper mine drainage and synthetic solutions of mine influenced water were filtered using the same membranes. These solutions were characterized by pH values within 2 and 5, thus crossing the iso-electric point of both membranes. Retention of cations was maximized when the feed solution pH was less than the iso-electric point of the membrane. In these conditions, the membrane has a net positive charge, reducing the transmission rate of cations. From the recoveries of a range of cations, the suitability of nanofiltration was discussed relative to the compliance with mine water discharge criteria and the recovery of valuable commodity metals. The nanofiltration process was demonstrated to offer advantages in metal recovery from mine waste streams, concomitantly enabling discharge criteria for the filtrate disposal to be met.

  16. Influence of pH on the localized corrosion of iron

    International Nuclear Information System (INIS)

    Webley, R.; Henry, R.

    1986-06-01

    The influence of pH on the pitting corrosion of iron in chloride and sulfate solutions was determined using two artificial pit apparatuses to obtain the pH near the surface of the pit bottom. A glass membrane electrode and an antimony electrode were used to measure pH in the two apparatuses. Using solutions of NaCl and Na 2 SO 4 at current densities of 0.5, 5.0, and 10 mA/cm 2 pH's in the range 5 to 6 were obtained with the first apparatus. The antimony probe did not measure pH accurately in solutions of 1 N NaCl and 1 N Na 2 SO 4 and had an error of approximately 2 pH units. A one-dimensional transport model was developed to predict pH variations around the pit mouth and inside the pit. The validity of this model was not verified due to the relative lack of precision with pH measurement techniques

  17. pH dependence of the aqueous dissolution rates of perovskite and zirconolite at 90 C

    International Nuclear Information System (INIS)

    McGlinn, P.J.; Hart, K.P.; Loi, E.H.; Vance, E.R.

    1995-01-01

    Perovskite and zirconolite are two of the major phases of the Synroc titanate mineral assemblage. Their aqueous durability under a range of pH conditions at 90 C has been examined. Solution analysis, electron microscopy and X-ray diffraction have been used to investigate the dissolution behavior of these phases, and a perovskite phase doped with Nd, Sr and Al, using buffered solutions at pH levels of 2.1, 3.7, 6.1, 7.9 and 12.9. After 43 days of leaching, Ca and Ti extractions from perovskite and zirconolite show only a weak pH-dependence. SEM investigation of the samples leached at pH 2.1, 6.1 and 12.9 showed that a titanaceous surface layer formed on the perovskite specimens. XRD analysis of the perovskite samples showed that anatase formed on the leached surface at acidic and neutral pHs, but not under alkaline conditions, and that minor amounts of rutile also formed. In the leached perovskite specimens doped with Nd, Sr and Al, no rule was found by XRD and anatase was only detected in the sample leached at pH 2.1. There were no detectable changes in the leached zirconolite samples examined by SEM and XRD

  18. Removal of heavy metals from synthetic solution by electrocoagulation

    Directory of Open Access Journals (Sweden)

    Mohamed Ilou

    2016-05-01

    Full Text Available The objective of this work concerns the optimization of the operating conditions for the removal of heavy metals from synthetic solution by Electrocoagulation (EC. To reach this purpose, we prepared a synthetic wastewater containing certain heavy metals (Ni, Cu, Zn, Fe and Pb to study the influence of various parameters (conductivity, pH, time of electrolysis, current density and the initial concentration of the metal on the rate of removal of these metals. The results show that this rate of removal can reach 99.9 % in the following optimal conditions: pH included between 6 and 8 and a density of the current of 1~1.5A / dm2. This study shows that it is possible to remove metals in aqueous solution by the technique of electrocoagulation. 

  19. Influence of pH on optoelectronic properties of zinc sulphide thin films prepared using hydrothermal and spin coating method

    Science.gov (United States)

    Choudapur, V. H.; Bennal, A. S.; Raju, A. B.

    2018-04-01

    The ZnS nanomaterial is synthesized by hydrothermal method under optimized conditions using Zinc acetate and sodium sulphide as precursors. The Zinc Sulphide thin films are obtained by simple spin coating method with high optical transmittance. The prepared thin films are adhesive and uniform. The x-ray diffraction analysis showed that the films are polycrystalline in cubic phase with the preferred orientation along (111) direction. Current-voltage curves were recorded at room temperature using Keithley 617 programmable electrometer and conductivity is calculated for the film coated on ITO by two probe method. The pH of the solution is varied by using ammonia and hydrochloric acid. The comparative studies of effect of pH on the morphology, crystallanity and optoelectronic properties of the films are studied. It is observed that the pH of the solution has large influence on optoelectronic properties. The thin film prepared with neutral pH has higher crystallanity, bandgap and conductivity as compared to the samples prepared in acidic or basic solutions.

  20. PIXE analysis of mineral composition of alfalfa root-tip exposed to low pH or aluminum stress condition

    International Nuclear Information System (INIS)

    Yokota, Satoshi; Mae, Tadahiko; Ojima, Kunihiko; Ishii, Keizo.

    1994-01-01

    PIXE analysis was applied to study alteration of mineral composition (Al, P, K, and Cl) of alfalfa root-tip exposed to low pH or aluminum stress. These minerals were detectable using one or two pieces of root-tips. Short-term (within 4 h) decreases in K/P and Cl/P ratios were observed under low pH and aluminum stress conditions. However, degree of the decrease was not same. Differences in toxic effects of low pH and Al on the root-tip of alfalfa are discussed. (author)

  1. pH in atomic scale simulations of electrochemical interfaces

    DEFF Research Database (Denmark)

    Rossmeisl, Jan; Chan, Karen; Ahmed, Rizwan

    2013-01-01

    Electrochemical reaction rates can strongly depend on pH, and there is increasing interest in electrocatalysis in alkaline solution. To date, no method has been devised to address pH in atomic scale simulations. We present a simple method to determine the atomic structure of the metal......|solution interface at a given pH and electrode potential. Using Pt(111)|water as an example, we show the effect of pH on the interfacial structure, and discuss its impact on reaction energies and barriers. This method paves the way for ab initio studies of pH effects on the structure and electrocatalytic activity...

  2. Role of Metal Cations on the corrosion behaviour of 8090-T851 in a pH 2.0 solution

    DEFF Research Database (Denmark)

    Murthy, K.S.N.; Ambat, Rajan; Dwarakadasa, E.S.

    1994-01-01

    The influence of cations such as Cu2+, Al3+ and Li+ on the corrosion behaviour of 8090-T851(Al-Li) alloy in a pH 2.0 HCl solution was investigated by weight loss and polarisation techniques. Weight loss experiments showed that the effect of cation is a strong function of its nature...

  3. Removal of Cr(VI) from aqueous solutions by a bacterial biofilm supported on zeolite: optimisation of the operational conditions and Scale-Up of the bioreactor

    Energy Technology Data Exchange (ETDEWEB)

    Pazos, M. [IBB - Instituto de Biotecnologia e Bioengenharia, Centro de Engenharia Biologica, Universidade do Minho, Braga (Portugal); Departamento de Ingenieria Quimica, Universidade de Vigo, Vigo (Spain); Branco, M.; Tavares, T. [IBB - Instituto de Biotecnologia e Bioengenharia, Centro de Engenharia Biologica, Universidade do Minho, Braga (Portugal); Neves, I.C. [Departamento de Quimica, Centro de Quimica, Universidade do Minho, Braga (Portugal); Sanroman, M.A. [Departamento de Ingenieria Quimica, Universidade de Vigo, Vigo (Spain)

    2010-12-15

    The aim of this study was to investigate the feasibility of a bioreactor system and its scale-up to remove Cr(VI) from solution. The bioreactor is based on an innovative process that combines bioreduction of Cr(VI) to Cr(III) by the bacterium Arthrobacter viscosus and Cr(III) sorption by a specific zeolite. Batch studies were conducted in a laboratory-scale bioreactor, taking into account different operating conditions. Several variables, such as biomass concentration, pH and zeolite pre-treatment, were evaluated to increase removal efficiency. The obtained results suggest that the Cr removal efficiency is improved when the initial biomass concentration is approximately 5 g L{sup -1} and the pH in the system is maintained at an acidic level. Under the optimised conditions, approximately 100 % of the Cr(VI) was removed. The scale-up of the developed biofilm process operating under the optimised conditions was satisfactorily tested in a 150-L bioreactor. (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Roles of iron species and pH optimization on sewage sludge conditioning with Fenton's reagent and lime.

    Science.gov (United States)

    Yu, Wenbo; Yang, Jiakuan; Shi, Yafei; Song, Jian; Shi, Yao; Xiao, Jun; Li, Chao; Xu, Xinyu; He, Shu; Liang, Sha; Wu, Xu; Hu, Jingping

    2016-05-15

    Conditioning sewage sludge with Fenton's reagent could effectively improve its dewaterability. However, drawbacks of conditioning with Fenton's reagent are requirement of acidic conditions to prevent iron precipitation and subsequent neutralization with alkaline additive to obtain the pH of the filtrate close to neutrality. In this study, roles of pH were thoroughly investigated in the acidification pretreatment, Fenton reaction, and the final filtrate after conditioning. Through the response surface methodology (RSM), the optimal dosages of H2SO4, Fe(2+), H2O2, and lime acted as a neutralizer were found to be 0 (no acidification), 47.9, 34.3 and 43.2 mg/g DS (dry solids). With those optimal doses, water content of the dewatered sludge cakes could be reduced to 55.8 ± 0.6 wt%, and pH of the final filtrate was 6.6 ± 0.2. Fenton conditioning without initial acidification can simplify the conditioning process and reduce the usage of lime. The Fe(3+) content in the sludge cakes showed a close correlation with the dewaterability of conditioned sludge, i.e., the water content of sludge cakes, SRF (specific resistance to filtration), CST (capillary suction time), bound water content, and specific surface area. It indicated that the coagulation by Fe(3+) species in Fenton reaction could play an important role, compared to traditional Fenton oxidation effect on sludge conditioning. Thus, a two-step mechanism of Fenton oxidation and Fe(III) coagulation was proposed in sewage sludge conditioning. The mechanisms include the following: (1) extracellular polymeric substances (EPS) were firstly degraded into dissolved organics by Fenton oxidation; (2) bound water was converted to free water due to degradation of EPS; (3) the sludge particles were disintegrated into small ones by oxidation; (4) Fe(3+) generated from Fenton reaction acted as a coagulant to agglomerate smaller sludge particles into larger dense particles with less bond water; (5) finally, the dewatered

  5. Stability of niclosamide in water under local conditions

    International Nuclear Information System (INIS)

    El Hindi, A.M.; Sidra, M.S.

    1986-01-01

    The stability of 14 C-labelled niclosamide was studied in distilled water at two different pH values and in canal water. 2 mg/1 niclosamide solutions were exposed to direct atmospheric conditions. The activity was followed by radioassay and the concentration of niclosamide was determined by GLC. The total activity was found to decrease to 46.0% in weakly acidic solution (pH 6.5), 45% in neutral solution (pH 7.0) and 16.7% in filtered canal water after three weeks. GLC analysis showed that niclosamide concentration had dropped to 0.05, 0.06 and 0.03 mg/1 in weakly acidic, neutral medium and canal water after the same period. GLC analysis as compared to radioassay indicated the presence of increasing amounts of degradation product(s), in the chloroform extracts of water with time, which were not detected by GLC

  6. Corrosion behavior of reinforcing steel in concrete for nuclear facilities exposed in high chloride and low pH environment

    International Nuclear Information System (INIS)

    Nishimura, Toshiyasu; Raman, Vedarajan

    2010-01-01

    The Cl ion concentration and pH were monitored by inserting micro-electrodes into artificial pores in the mortar which was exposed in 0.5 mol/l chloride solution (pH 4.0). At the same time, the electrochemical behavior of the reinforcing steel was investigated by EIS. The Cl ion concentration in the mortar was obtained using Ag/AgCl micro-electrodes, showing that this behavior is generally controlled by diffusion. When the diffusion equation was used in this work, the diffusion coefficient (D c ) showed a high value of D c = 9.5 x 10 -5 mm 2 /s. Similarly, the pH in the mortar was obtained using W/WO x micro-electrodes. With a 10 mm cover thickness, pH continued to decrease to pH 8.0, which was considered by penetration of H + ions from the surface. Based on the results of monitoring with the micro-electrodes, solutions simulating those in the pores in mortar were prepared and used in EIS measurements. The charge transfer resistance R ct in the simulated solutions showed good correspondence with the impedance Z (Z 1mHz -Z sol ) in the actual mortar. This is attributed to the fact that the corrosion of reinforcing steel was controlled by the solution conditions (mainly Cl concentration and pH) in the pores in mortar.

  7. Adsorção de cromo (VI por carvão ativado granular de soluções diluídas utilizando um sistema batelada sob pH controlado Chromium (VI adsorption by GAC from diluted solutions in batch system and controlled ph

    Directory of Open Access Journals (Sweden)

    Renata Santos Souza

    2009-09-01

    solutions, and batch systems with controlled pH. The functional groups on the CAG surface was carried out by the Boehm method. In addition, effect of pH on the Cr(VI adsorption, adsorption equilibrium, and kinetic were studied under experimental conditions (pH = 6, MA = 6g, for 90min.. On the GAC surface, carboxylic groups were found to be in higher concentrations (MAS=0,43 mmol/gCAG, which increase the Cr(VI adsorption, principally in acidic pH values. The adsorption capacity is dependent on the pH of the solution, due to its influence on the surface properties of the CAG and different ionic forms of the Cr(VI solutions. The adsorption equilibrium data was adjusted satisfactorily by the Langmuir isotherm (R²=0,988, favorable type. From kinetics adsorption of 20 mg/L and 5 mg/L, the results were compatible with the national legislation (Res. nº 357/05. Therefore, the experimental system using (CAG was efficient in removing the Cr(VI from liquid streams containing low concentrations of the metal.

  8. The stability of water- and fat-soluble vitamin in dentifrices according to pH level and storage type.

    Science.gov (United States)

    Park, Jung-Eun; Kim, Ki-Eun; Choi, Yong-Jun; Park, Yong-Duk; Kwon, Ha-Jeong

    2016-02-01

    The purpose of this study is to evaluate the vitamin stabilities in dentifrices by analyzing various vitamins according to the level and storage temperature. The stabilities of water- and fat-soluble vitamins were investigated in buffer solution at different pH values (4, 7, 8, 10 and 11) for 14 days and in dentifrices at different pH (7 and 10) for 5 months at two temperature conditions (room and refrigeration temperature) by analyzing the remaining amounts using HPLC methods. In the buffer solution, the stability of vitamins B1 , B6 and C was increased as the pH values increased. Vitamins E and K showed poor stability at pH 4, and vitamin B3 showed poor stability at pH 11. In dentifrices, the storage temperature highly influenced vitamin stability, especially vitamins C and E, but the stabilities of vitamins B1 and C according to pH values did not correspond to the buffer solution tests. Vitamin B group was relatively stable in dentifrices, but vitamin C completely disappeared after 5 months. Vitamin K showed the least initial preservation rates. Vitamins were not detected in commercial dentifrices for adults and detected amounts were less than the advertised contents in dentifrices for children. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Effect of environmental and cultural conditions on medium pH and explant growth performance of Douglas-fir ( Pseudotsuga menziesii) shoot cultures

    OpenAIRE

    Chen, Chien-Chih; Bates, Rick; Carlson, John

    2015-01-01

    The medium pH level of plant tissue cultures has been shown to be essential to many aspects of explant development and growth. Sensitivity or tolerance of medium pH change in vitro varies according to specific requirements of individual species. The objectives of this study are to 1) determine medium pH change over time in storage conditions and with presence of explants, 2) evaluate the effects of medium pH change on explant growth performance and 3) assess the effects of adding a pH stabili...

  10. Continuous measurement of electrical characteristics in plants. 3. Shokubutsu seitai no denki tokusei sokuteiho. 3. ; Suikoeki pH chosei heno tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Sekiyama, T; Haniyu, H; Saiki, H

    1989-09-01

    Controlling pH of nutrient solution and keeping the other conditions unchanged, measurements of variation in electric potential difference between leaf and hypocotyl of a bush bean plant was performed for about seven days. Silver electrodes 0.3mm in diameter were glued on the surface of the plant using conductive paste prepared by dissolving gelatine in Ringel {prime} s solution. The results obtained are summarized as follws: first, when pH of the solution is suddenly increased or decreased, the potential of leave becomes high or low with respect to that of hypocotyl respectively; second, the variation in potential difference between them is affected by the rate at which pH of the solution is adjusted, although the total variation of pH is controlled to be the same, and in particular by mild adjustment (0.02 - 0.05pH/min) it is reduced to 1/2 - 1/4 of that produced by sudden change; third, abrupt change in pH of the solution cause to the plant the temporary suppression of its water absorption having a duration of 7 - 15 minutes. A short account is given of a non-contact type measurement of bioelectric potential performanced by making use of a Faraday {prime} s cage. 11 refs., 12 figs.

  11. Determining pH at elevated pressure and temperature using in situ ¹³C NMR.

    Science.gov (United States)

    Surface, J Andrew; Wang, Fei; Zhu, Yanzhe; Hayes, Sophia E; Giammar, Daniel E; Conradi, Mark S

    2015-02-03

    We have developed an approach for determining pH at elevated pressures and temperatures by using (13)C NMR measurements of inorganic carbon species together with a geochemical equilibrium model. The approach can determine in situ pH with precision better than 0.1 pH units at pressures, temperatures, and ionic strengths typical of geologic carbon sequestration systems. A custom-built high pressure NMR probe was used to collect (13)C NMR spectra of (13)C-labeled CO2 reactions with NaOH solutions and Mg(OH)2 suspensions at pressures up to 107 bar and temperatures of 80 °C. The quantitative nature of NMR spectroscopy allows the concentration ratio [CO2]/[HCO3(-)] to be experimentally determined. This ratio is then used with equilibrium constants calculated for the specific pressure and temperature conditions and appropriate activity coefficients for the solutes to calculate the in situ pH. The experimentally determined [CO2]/[HCO3(-)] ratios agree well with the predicted values for experiments performed with three different concentrations of NaOH and equilibration with multiple pressures of CO2. The approach was then applied to experiments with Mg(OH)2 slurries in which the change in pH could track the dissolution of CO2 into solution, rapid initial Mg(OH)2 dissolution, and onset of magnesium carbonate precipitation.

  12. Structural match of heterogeneously nucleated Mn(OH)_2(s) nanoparticles on quartz under various pH conditions

    International Nuclear Information System (INIS)

    Jung, Haesung; Lee, Byeongdu; Jun, Young-Shin

    2016-01-01

    The early nucleation stage of Mn (hydr)oxide on mineral surfaces is crucial to understand its occurrence and the cycling of nutrients in environmental systems. However, there are only limited studies on the heterogeneous nucleation of Mn(OH)_2(s) as the initial stage of Mn (hydr)oxide precipitation. Here, we investigated the effect of pH on the initial nucleation of Mn(OH)_2(s) on quartz. Under various pH conditions of 9.8, 9.9, and 10.1, we analyzed the structural matches between quartz and heterogeneously nucleated Mn(OH)_2(s). The structural matches were calculated by measuring lateral and vertical dimensions using grazing incidence small angle X-ray scattering (GISAXS) and atomic force microscopy (AFM), respectively. We found that a poorer structural match occurred at a higher pH than at a lower pH. The faster nucleation at a higher pH condition accounted for the observed poorer structural match. By fitting the structural match using classical nucleation theory, we also calculated the interfacial energy between Mn(OH)_2(s) and water (γ_n_f = 71 ± 7 mJ/m"2). The calculated m values and γ_n_f provided the variance of interfacial energy between quartz and Mn(OH)_2(s): γ_s_n = 262–272 mJ/m"2. As a result, this study provides new qualitative and quantitative information about heterogeneous nucleation on environmentally an abundant mineral surface, quartz, and it offers important underpinnings for understanding the fate and transport of trace ions in environmental systems.

  13. Soil solution interactions may limit Pb remediation using P ...

    Science.gov (United States)

    Lead (Pb) contaminated soils are a potential exposure hazard to the public. Amending soils with phosphorus (P) may reduce Pb soil hazards. Soil from Cleveland, OH containing 726 ± 14 mg Pb kg-1 was amended in a laboratory study with bone meal and triple super phosphate (TSP) at 5:1 P:Pb molar ratios. Soil was acidified, neturalized and re-acidified to encourage Pb phosphate formation. PRSTM-probes were used to evaluate changes in soil solution chemistry. Soil acidification did not decrease in vitro bioaccessible (IVBA) Pb using either a pH 1.5, 0.4 M glycine solution or a pH 2.5 solution with organic acids. PRSTM-probe data found soluble Pb increased 10-fold in acidic conditions compared to circumnetural pH conditions. In acidic conditions (p = 3-4), TSP treated soils increased detected P 10-fold over untreated soils. Bone meal application did not increase PRSTM-probe detected P, indicating there may have been insufficient P to react with Pb. X-ray absorption spectroscopy suggested a 10% increase in pyromorphite formation for the TSP treated soil only. Treatments increased soil electrical conductivity above 16 mS cm-1, potentially causing a new salinity hazard. This study used a novel approach by combining the human ingestion endpoint, PRSTM-probes, and X-ray absorption spectroscopy to evaluate treatment efficacy. PRSTM-probe data indicated potentially excess Ca relative to P across incubation steps that could have competed with Pb for soluble P. Mor

  14. pH dependent polymeric micelle adsorption

    Energy Technology Data Exchange (ETDEWEB)

    McLean, S C; Gee, M L [The University of Melbourne, VIC (Australia). School of Chemistry

    2003-07-01

    Full text: Poly(2-vinylpyridine)-poly(ethylene oxide) (P2VP-PEO) shows potential as a possible drug delivery system for anti-tumour drugs since it forms pH dependent polymeric micelles. Hence to better understand the adsorption behaviour of this polymer we have studied the interaction forces between layers of P2VP-PEO adsorbed onto silica as a function of solution pH using an Atomic Force Microscope (AFM). When P2VP-PEO is initially adsorbed above the pKa of the P2VP block, P2VP-PEO adsorbs from solution as micelles that exist as either partially collapsed- or a hemi-micelles at the silica surface. Below the pKa of P2VP, the P2VP-PEO adsorbs as unimers, forming a compact layer with little looping and tailing into solution. When initial adsorption of P2VP-PEO is in the form of unimers, any driving force to self-assembly of the now charge neutral polymer is kinetically hindered. Hence, after initial adsorption at pH 3.6, a subsequent increase in pH to 6.6 results in a slow surface restructuring towards self-assembly and equilibrium. When the pH is increased from pH 6.6 to 9.7 there is a continuation of the evolution of the system to its equilibrium position during which the adsorbed P2VP-PEO unimers continue to 'unravel' from the surface, extending away from it, towards eventual complete surface self-assembly.

  15. Comparing the acidities of aqueous, frozen, and freeze-dried phosphate buffers: Is there a "pH memory" effect?

    Science.gov (United States)

    Vetráková, Ľubica; Vykoukal, Vít; Heger, Dominik

    2017-09-15

    The concept of "pH memory" has been established in the literature for the correlation between the pH of a pre-lyophilization solution and the ionization state of freeze-dried powder (lyophile). In this paper, the concept of "pH memory" is explored for the system of an aqueous solution, a frozen solution, and a lyophile. Sodium and potassium phosphate buffers in the pH range of 5-9 were frozen and lyophilized with sulfonephthalein indicators as acidity probes, and their Hammett acidity functions were compared to the initial pH of the aqueous solution. The results show that the acidities of the lyophiles are somewhat changed compared to the initial pHs, but the acidities in the frozen state differ more substantially. The Hammett acidity functions of the frozen buffers were found to be markedly dissimilar from the initial pH, especially in the sodium phosphate frozen at 233K, where an increase in the initial pH led to a decrease in the Hammett acidity function of the frozen state at a certain pH range. The large acidification observed after freezing the sodium phosphate buffer was not detected in the lyophiles after the sample had been dried; the phenomenon is explained considering the formed crystals analyzed by X-ray powder diffraction. The results suggest that monitoring the final acidity of a lyophile is not sufficient to predict all the acidity changes throughout the whole lyophilization process. The importance of well-controlled freezing and lyophilization conditions follows from the results of the research. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Redox behavior of Tc(VII)/Tc(IV) under various reducing conditions in 0.1 M NaCl solutions

    International Nuclear Information System (INIS)

    Kobayashi, T.; Gaona, X.; Altmaier, M.; Scheinost, A.C.; Fellhauer, D.; European Commission Joint Research Centre, Karlsruhe

    2013-01-01

    Redox behaviour of Tc(VII)/Tc(IV) was investigated in 0.1 M NaCl solutions containing different reducing agents in the pH range 2 to 13 at 22 C under inert Ar atmosphere. In several samples, the 1 x 10 -5 mol/dm 3 (M) initially added TcO 4 - was reduced to form a Tc(IV) oxide solid phase with low solubility. The observed Tc redox transformation processes are systematized according to E h -pH conditions in solution, indicating that a borderline for the reduction of Tc(VII) to Tc(IV), TcO 4 - + 3e - + 4H + TcO 2 . xH 2 O(coll, hyd) + (2-x)H 2 O exists, independent of the reducing chemical system. This experimentally derived borderline is about 100 mV lower than the equilibrium line calculated from the reported standard redox potential of TcO 2 . 1.6H 2 O(s). This behaviour can be related to the existence of more soluble solid phase modifications, i.e. nanoparticulate Tc(IV) oxide species TcO 2 . xH 2 O(coll, hyd). The reaction kinetics likewise correlate to the redox potential measured in solution. Slow reduction of Tc(VII) to Tc(IV) was observed when the redox potential in the system was slightly below the above mentioned reduction borderline. Fast reduction was observed in the systems far below the borderline, but also in those systems containing Fe(II) solids, suggesting a specific surface mediated effect in the reduction process. EXAFS analysis on two magnetite samples indicate reduced Tc(IV) species which do not remain adsorbed at the reactive mineral surface and are incorporated in the magnetite structure. (orig.)

  17. pH tolerance of Daphnia pulex (leydig, emend. , richard)

    Energy Technology Data Exchange (ETDEWEB)

    Davis, P; Ozburn, G W

    1969-01-01

    The survival time and reproduction of female Daphnia pulex in solutions varying in pH have been observed. Dilute sodium hydroxide or sulfuric acid solutions were added to four different diluent waters: distilled water, aerated tap water, aerated and filtered tap water from an aquarium containing Dace minnows, and Mcintyre River water. D. Pulex (initially up to 72 hours old) survived for the duration of the experiment (32 hours) in river water within a pH range of 6.1 to 10.3; in aquarium water within a pH range of 4.3 to 10.4; only at pH 6.4 and pH 7.6 in distilled water; and in none of the solutions using aerated tap water. The dissolved oxygen content was measured at the beginning and end of every experiment and was found never to fall below 6.2 p.p.M. Those individuals which survived were cultured in the laboratory and parthenogenesis was observed at pH values between 7.0 and 8.7.

  18. Stability of poly(N-isopropylacrylamide-co-acrylic acid polymer microgels under various conditions of temperature, pH and salt concentration

    Directory of Open Access Journals (Sweden)

    Zahoor H. Farooqi

    2017-03-01

    Full Text Available This research article describes the colloidal stability of poly(N-isopropylacrylamide-co-acrylic acid [P(NIPAM-co-AAc] polymer microgels with different acrylic acid contents in aqueous medium under various conditions of temperature, pH and sodium chloride concentrations. Three samples of multi-responsive P(NIPAM-co-AAc polymer microgels were synthesized using different amounts of acrylic acid by free radical emulsion polymerization. Dynamic laser light scattering was used to investigate the responsive behavior and stability of the prepared microgels under various conditions of pH, temperature and ionic strength. The microgels were found to be stable at all pH values above the pKa value of acrylic acid moiety in the temperature range from 15 to 60 °C in the presence and absence of sodium chloride. Increase in temperature, salt concentration and decrease in pH causes aggregation and decreases the stability of microgels due to the decrease in hydrophilicity.

  19. Development and characterization of a voltammetric carbon-fiber microelectrode pH sensor.

    Science.gov (United States)

    Makos, Monique A; Omiatek, Donna M; Ewing, Andrew G; Heien, Michael L

    2010-06-15

    This work describes the development and characterization of a modified carbon-fiber microelectrode sensor capable of measuring real-time physiological pH changes in biological microenvironments. The reagentless sensor was fabricated under ambient conditions from voltammetric reduction of the diazonium salt Fast Blue RR onto a carbon-fiber surface in aprotic media. Fast-scan cyclic voltammetry was used to probe redox activity of the p-quinone moiety of the surface-bound molecule as a function of pH. In vitro calibration of the sensor in solutions ranging from pH 6.5 to 8.0 resulted in a pH-dependent anodic peak potential response. Flow-injection analysis was used to characterize the modified microelectrode, revealing sensitivity to acidic and basic changes discernible to 0.005 pH units. Furthermore, the modified electrode was used to measure dynamic in vivo pH changes evoked during neurotransmitter release in the central nervous system of the microanalytical model organism Drosophila melanogaster.

  20. Control of lead solubility in soil contaminated with lead shot: Effect of soil pH

    International Nuclear Information System (INIS)

    Rooney, Corinne P.; McLaren, Ronald G.; Condron, Leo M.

    2007-01-01

    An incubation experiment was carried out to assess the rate of oxidation of Pb shot and subsequent transfer of Pb to the soil under a range of soil pH conditions. Lead shot corrosion was rapid, so that soil solution and fine earth ( 3 (CO 3 ) 2 (OH) 2 ), developed in crusts surrounding individual Pb pellets. However, irrespective of pH, Pb 2+ activities in the soil solutions, modelled using WHAM 6, were much lower than would be the case if they were controlled by the solubility of the dominant Pb compounds present in the Pb shot crust material. In contrast, modelling of soil solid-solution phase distribution of Pb, again using WHAM 6, suggested that, at least during the 24 months of the study, soil solution Pb concentrations were more likely to be controlled by sorption of Pb by the soil solid phase. - Sorption processes control Pb 2+ ion activity in soils contaminated with Pb shot

  1. Decoloration and mineralization of aqueous solution of cationic (basic) dye Astrazon Black FDL by using gamma rays

    International Nuclear Information System (INIS)

    Kantoglu, Oemer

    2017-01-01

    Degree of decolorization due to the irradiation of aqueous solutions of commercial cationic (basic) Astrazon Black FDL textile dye was studied in this study. Factor effecting radiolysis of the dye such as dye concentration, absorbed dose, toxicity, COD, BOD_5 and pH of solutions were studied at air, O_2 saturated and H_2O_2 environments. Unirradiated Astrazon Black FDL was non-biodegradable, whereas it was biodegradable after irradiation. The biodegradability (BOD_5/COD) increased at 2 kGy for Astrazon Black FDL in all solutions. The biorefractory organic compounds were converted into more easily biodegradable compounds having lower molecular weights. In optimum dose and pH determination experiments, 5 kGy pH 12 at air, 7 kGy pH 3 at O_2 saturated, 9 kGy pH 3 at 2.6 mM H_2O_2 for Astrazon Black FDL were found as the optimum irradiation conditions. Toxicity level of unirradiated solutions was high, whereas toxicity level of irradiated solutions was lower.

  2. Decoloration and mineralization of aqueous solution of cationic (basic) dye Astrazon Black FDL by using gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Kantoglu, Oemer [Turkish Atomic Energy Authority, Ankara (Turkey). Saraykoey Nuclear Research and Training Center

    2017-06-01

    Degree of decolorization due to the irradiation of aqueous solutions of commercial cationic (basic) Astrazon Black FDL textile dye was studied in this study. Factor effecting radiolysis of the dye such as dye concentration, absorbed dose, toxicity, COD, BOD{sub 5} and pH of solutions were studied at air, O{sub 2} saturated and H{sub 2}O{sub 2} environments. Unirradiated Astrazon Black FDL was non-biodegradable, whereas it was biodegradable after irradiation. The biodegradability (BOD{sub 5}/COD) increased at 2 kGy for Astrazon Black FDL in all solutions. The biorefractory organic compounds were converted into more easily biodegradable compounds having lower molecular weights. In optimum dose and pH determination experiments, 5 kGy pH 12 at air, 7 kGy pH 3 at O{sub 2} saturated, 9 kGy pH 3 at 2.6 mM H{sub 2}O{sub 2} for Astrazon Black FDL were found as the optimum irradiation conditions. Toxicity level of unirradiated solutions was high, whereas toxicity level of irradiated solutions was lower.

  3. Existence of weak solutions to first-order stationary mean-field games with Dirichlet conditions

    KAUST Repository

    Ferreira, Rita; Gomes, Diogo A.; Tada, Teruo

    2018-01-01

    In this paper, we study first-order stationary monotone mean-field games (MFGs) with Dirichlet boundary conditions. While for Hamilton--Jacobi equations Dirichlet conditions may not be satisfied, here, we establish the existence of solutions of MFGs that satisfy those conditions. To construct these solutions, we introduce a monotone regularized problem. Applying Schaefer's fixed-point theorem and using the monotonicity of the MFG, we verify that there exists a unique weak solution to the regularized problem. Finally, we take the limit of the solutions of the regularized problem and using Minty's method, we show the existence of weak solutions to the original MFG.

  4. Economical wireless optical ratiometric pH sensor

    International Nuclear Information System (INIS)

    Vuppu, Sandeep; Kostov, Yordan; Rao, Govind

    2009-01-01

    The development and application of a portable, wireless fluorescence-based optical pH sensor is presented. The design incorporates the MSP430 microcontroller as the control unit, an RF transceiver for wireless communication, digital filters and amplifiers and a USB-based communication module for data transmission. The pH sensor is based on ratiometric fluorescence detection from pH sensitive dye incorporated in a peel-and-stick patch. The ability of the instrument to detect the pH of the solution with contact only between the sensor patch and the solution makes it partially non-invasive. The instrument also has the ability to transmit data wirelessly, enabling its use in processes that entail stringent temperature control and sterility. The use of the microcontroller makes it a reliable, low-cost and low-power device. The luminous intensity of the light source can be digitally controlled to maximize the sensitivity of the instrument. It has a resolution of 0.05 pH. The sensor is accurate and reversible over the pH range of 6.5–9

  5. Effect of pH and soil structure on transport of sulfonamide antibiotics in agricultural soils.

    Science.gov (United States)

    Park, Jong Yol; Huwe, Bernd

    2016-06-01

    We investigated the effect of solution pH and soil structure on transport of sulfonamide antibiotics (sulfamethoxazole, sulfadimethoxine and sulfamethazine) in combination with batch sorption tests and column experiments. Sorption isotherms properly conformed to Freundlich model, and sorption potential of the antibiotics is as follows; sulfadimethoxine > sulfamethoxazole > sulfamethazine. Decreasing pH values led to increased sorption potential of the antibiotics on soil material in pH range of 4.0-8.0. This likely resulted from abundance of neutral and positive-charged sulfonamides species at low pH, which electrostatically bind to sorption sites on soil surface. Due to destruction of macropore channels, lower hydraulic conductivities of mobile zone were estimated in the disturbed soil columns than in the undisturbed soil columns, and eventually led to lower mobility of the antibiotics in disturbed column. The results suggest that knowledge of soil structure and solution condition is required to predict fate and distribution of sulfonamide antibiotics in environmental matrix. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Stability of Anthocyanins and Their Degradation Products from Cabernet Sauvignon Red Wine under Gastrointestinal pH and Temperature Conditions.

    Science.gov (United States)

    Yang, Ping; Yuan, Chunlong; Wang, Hua; Han, Fuliang; Liu, Yangjie; Wang, Lin; Liu, Yang

    2018-02-07

    This study investigated the stability of wine anthocyanins under simulated gastrointestinal pH and temperature conditions, and further studied the evolution of anthocyanin degradation products through simulated digestive conditions. The aim of this study was to investigate the relation between anthocyanins' structure and their digestive stability. Results showed that a total of 22 anthocyanins were identified in wine and most of these anthocyanins remained stable under simulated gastric digestion process. However, a dramatic concentration decrease happened to these anthocyanins during simulated intestinal digestion. The stability of anthocyanins in digestive process appeared to be related to their structure. The methoxy group in the B-ring enhanced the stability of anthocyanins, whereas hydroxyl group resulted in a reduction of their stability. Acylation decreased the stability of malvidin 3- O -glucoside. Pyruvic acid conjugation enhanced the structural stability of pyranoanthocyanins, whereas acetaldehyde attachment weakened their stability. A commercial malvidin 3- O -glucoside standard was used to investigate anthocyanin degradation products under simulated digestion process, and syringic acid, protocatechuic acid and vanillic acid were confirmed to be the degradation products via anthocyanin chalcone conversion path. Gallic acid, protocatechuic acid, vanillic acid, syringic acid, and p -coumaric acid in wine experienced a significant concentration decrease during digestion process. However, wine model solution revealed that phenolic acids remained stable under gastrointestinal conditions, except gallic acid.

  7. Stability of Anthocyanins and Their Degradation Products from Cabernet Sauvignon Red Wine under Gastrointestinal pH and Temperature Conditions

    Directory of Open Access Journals (Sweden)

    Ping Yang

    2018-02-01

    Full Text Available This study investigated the stability of wine anthocyanins under simulated gastrointestinal pH and temperature conditions, and further studied the evolution of anthocyanin degradation products through simulated digestive conditions. The aim of this study was to investigate the relation between anthocyanins’ structure and their digestive stability. Results showed that a total of 22 anthocyanins were identified in wine and most of these anthocyanins remained stable under simulated gastric digestion process. However, a dramatic concentration decrease happened to these anthocyanins during simulated intestinal digestion. The stability of anthocyanins in digestive process appeared to be related to their structure. The methoxy group in the B-ring enhanced the stability of anthocyanins, whereas hydroxyl group resulted in a reduction of their stability. Acylation decreased the stability of malvidin 3-O-glucoside. Pyruvic acid conjugation enhanced the structural stability of pyranoanthocyanins, whereas acetaldehyde attachment weakened their stability. A commercial malvidin 3-O-glucoside standard was used to investigate anthocyanin degradation products under simulated digestion process, and syringic acid, protocatechuic acid and vanillic acid were confirmed to be the degradation products via anthocyanin chalcone conversion path. Gallic acid, protocatechuic acid, vanillic acid, syringic acid, and p-coumaric acid in wine experienced a significant concentration decrease during digestion process. However, wine model solution revealed that phenolic acids remained stable under gastrointestinal conditions, except gallic acid.

  8. Radiolysis of permanganate and its mixtures with bromate and nitrate ions in solution at pH 10

    International Nuclear Information System (INIS)

    Dedgaonkar, V.G.; Kulkarni, S.A.; Mahajan, C.T.

    1981-01-01

    γ-radiolysis of aqueous solutions of pure permanganate and its binary mixture with nitrite and bromate ions at pH 10 is studied as a function of concentration and dose. In pure system G(-MnO 4 - ) increases with the increase in initial concentration from 0.68 to a maximum of 25. The rise is sharp above 10 -2 M concentration which indicates the occurrence of a chain mechanism. In the presence of bromate or nitrite the G value decreases: the G(-MnO 4 - ) in 10 -3 M permanganate solution is 1.07, with 10 -1 M bromate it is 0.2 and with 10 -2 M nitrite it is 0.7. A mechanism based on the cometitive kinetics is envisaged to explain the observed results. (author)

  9. Programmable pH buffers

    Science.gov (United States)

    Gough, Dara Van; Huber, Dale L.; Bunker, Bruce C.; Roberts, Mark E.

    2017-01-24

    A programmable pH buffer comprises a copolymer that changes pK.sub.a at a lower critical solution temperature (LCST) in water. The copolymer comprises a thermally programmable polymer that undergoes a hydrophobic-to-hydrophilic phase change at the LCST and an electrolytic polymer that exhibits acid-base properties that are responsive to the phase change. The programmable pH buffer can be used to sequester CO.sub.2 into water.

  10. Effect of the temperature, pH and irradiance on the photosynthetic activity by Scenedesmus obtusiusculus under nitrogen replete and deplete conditions.

    Science.gov (United States)

    Cabello, Juan; Toledo-Cervantes, Alma; Sánchez, León; Revah, Sergio; Morales, Marcia

    2015-04-01

    This paper evaluates the effect of the irradiance, pH and temperature on the photosynthetic activity (PA) of Scenedesmus obtusiusculus under N-replete and N-deplete conditions through oxygen measurements. The highest PA values were 160 mgO2 gb(-1) h(-1) at 620 μmol m(-2) s(-1), 35 °C and pH of 8 under N-replete conditions and 3.3 mgO2 gb(-1) h(-1) at 100 μmol m(-2) s(-1), 28.5 °C and pH of 5.5 for N-deplete conditions. Those operation conditions were tested in a flat-panel photobioreactor. The biomass productivity was 0.97 gb L(-1) d(-1) under N-replete conditions with a photosynthetic efficiency (PE) of 4.4% yielding 0.85 gb mol photon(-1). Similar biomass productivity was obtained under N-deplete condition; and the lipid productivity was 0.34 gL L(-1) d(-1) with a PE of 7.8% yielding 0.39 gL mol photon(-1). The apparent activation and deactivation energies were 16.1 and 30 kcal mol(-1), and 11.9 and 15.3 kcal mol(-1), for N-replete and N-deplete conditions, respectively. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Interaction between U(VI) and Fe(II) in aqueous solution under anaerobic conditions. Closed system experiments

    International Nuclear Information System (INIS)

    Myllykylae, E.; Ollila, K.

    2011-01-01

    The aim of these experiments is to investigate the potential reduction of U(VI) carbonate and hydroxide complexes by aqueous Fe(II). This reduction phenomenon could be important under the disposal conditions of spent fuel. If groundwater enters the copper/iron canister, alpha radiolysis of the water may locally induce oxidizing conditions on the surface of UO 2 fuel, leading to the dissolution of UO 2 as more soluble U(VI) species. A potential reducing agent in the intruding water is Fe(II)(aq) from anaerobic corrosion of the copper/iron canister. The reduction of U(VI) to U(IV) would substantially decrease the solubility of U as well as co-precipitate other actinides and radionuclides. The interaction experiments were conducted in 0.01 M NaCl and 0.002 M NaHCO 3 solutions using an initial uranium concentration of either 8.4 x 10 -8 or 4.2 x 10 -7 mol/L with an initial Fe(II) concentration of 1.8 x 10 -6 in the NaCl solutions and 1.3 x 10 -6 mol/L in the NaHCO 3 solutions. Only after an equilibration period for U(VI) complexation was Fe(II) added to the solutions. The reaction times varied from 1 week to 5 months. For extra protection against O 2 , even inside a glove-box (N 2 atmosphere), the plastic reaction vessels were closed in metallic containers. The concentrations of U, Fe TOT and Fe(II) were analysed as a function of time for unfiltered, micro- and ultrafiltered samples. In addition, the precipitate on the ultrafilters was analysed with ESEM-EDS. The evolution of pH and Eh values was measured. The oxidation state of U in solution was preliminarily analysed for chosen periods. The results of the tests in 0.01 M NaCl showed an initial rapid decrease in U concentration after the addition of Fe(II) to the solution. The U found on test vessel walls at the end of the reaction periods, as well as the ESEM-EDS analyses of the filtered precipitates from the test solutions, showed that precipitation of U had occurred. The oxidation state analyses showed the presence

  12. UO2 leaching and radionuclide release modelling under high and low ionic strength solution and oxidation conditions

    International Nuclear Information System (INIS)

    1995-01-01

    In this work, the UO 2 dissolution under oxidizing conditions has been studied in order to compare these results to those obtained with spent fuel. Two different leaching solutions have been used, one with a high ionic strength trying to simulate the conditions expected in a saline repository and the other at low ionic strength much appropriate to granitic environments. In both cases, the dissolution has been studied studied as a function of pH, redox potential, oxidants, complexing agents, particle size as well as the experimental methodology. Results can be summarized as follows: a) The UO 2 dissolution is rather independent on ionic strength. b) Dissolution rates can be explained in general independent on the oxidant as: Log R=3DK [oxidant] Surface solid evolution is very important to understand the dissolution/oxidation mechanism of UO 2 . d) Under oxidizing conditions, the dissolution is H+ and HCO 3 promoted. e) In carbonate medium, both UO 2 and spent fuel dissolution rates are very similar, while in a non-complexing medium, spent fuel dissolution rate is much higher than the UO 2 one. This fact seems to indicate that radiolysis is much important non-complexing media. (Author)

  13. "On-off-on" switchable sensor: a fluorescent spiropyran responds to extreme pH conditions and its bioimaging applications.

    Science.gov (United States)

    Wan, Shulin; Zheng, Yang; Shen, Jie; Yang, Wantai; Yin, Meizhen

    2014-11-26

    A novel spiropyran that responds to both extreme acid and extreme alkali and has an "on-off-on" switch is reported. Benzoic acid at the indole N-position and carboxyl group at the indole 6-position contribute to the extreme acid response. The ionizations of carboxyl and phenolic hydroxyl groups cause the extreme alkali response. Moreover, the fluorescent imaging in bacterial cells under extreme pH conditions supports the mechanism of pH response.

  14. Corrosion of glass-bonded sodalite as a function of pH and temperature

    International Nuclear Information System (INIS)

    Morss, L. R.; Stanley, M.; Tatko, C.; Ebert, W. L.

    1999-01-01

    This paper reports the results of corrosion tests with monoliths of sodalite, binder glass, and glass-bonded sodalite, a ceramic waste form (CWF) that is being developed to immobilize radioactive electrorefiner salt used to condition spent sodium-bonded nuclear fuel. These tests were performed with dilute pH-buffered solutions in the pH range of 5-10 at temperatures of 70 and 90 C. The pH dependence of the forward dissolution rates of the CWF and its components have been determined. The pH dependence of the dissolution rates of sodalite, binder glass, and glass-bonded sodalite are similar to the pH dependence of dissolution rate of borosilicate nuclear waste glasses, with a negative pH dependence in the acidic region and a positive pH dependence in the basic region. Our results on the forward dissolution rates and their temperature and pH dependence will be used as components of a waste form degradation model to predict the long-term behavior of the CWF in a nuclear waste repository

  15. Existence of weak solutions to first-order stationary mean-field games with Dirichlet conditions

    KAUST Repository

    Ferreira, Rita

    2018-04-19

    In this paper, we study first-order stationary monotone mean-field games (MFGs) with Dirichlet boundary conditions. While for Hamilton--Jacobi equations Dirichlet conditions may not be satisfied, here, we establish the existence of solutions of MFGs that satisfy those conditions. To construct these solutions, we introduce a monotone regularized problem. Applying Schaefer\\'s fixed-point theorem and using the monotonicity of the MFG, we verify that there exists a unique weak solution to the regularized problem. Finally, we take the limit of the solutions of the regularized problem and using Minty\\'s method, we show the existence of weak solutions to the original MFG.

  16. Optimization of pH and direct imaging conditions of complexed ...

    Indian Academy of Sciences (India)

    Unknown

    Materials with light induced absorption or refractive index changes are of ... showed that high pH and high exposure energy gave .... Figure 4. A plot of rate of bleaching vs time for different pH. ... Moreover, it does not need any dark room.

  17. Equilibrium leach tests with cobalt in the system cemented waste form/container material/aqueous solution

    International Nuclear Information System (INIS)

    Vejmelka, P.; Koester, R.; Lee, M. J.; Han, K. W.

    1991-01-01

    The equilibrium concentrations of Co in the system of cemented waste form/aqueous solutions were determined including the effect of the container material and its corrosion products under the respective conditions. The chemical conditions in the near field of the waste form were characterized by measurement of the pH and E h value. As disposal relevant solutions, saturated sodium chloride, Q-brine (main constituent MgCl 2 ) and a granitic type groundwater were used. For comparison, also experiments using deionized water were performed. In all systems investigated the cemented waste form itself has a strong influence on the chemical conditions in the near field. The pH and E h values are affected in all cases by the addition of the cemented waste form. There is no or only a slight difference between the E h values if iron powder or iron hydroxide is added to the cemented waste form/solution systems, but the E h is markedly decreased when iron powder is added to the solution free of cement. The Co concentration is decreased in all solutions by the addition of the cemented waste form, the largest effect is observed in Q-brine and this can be attributed either to the sorption of the Co-ions on the corrosion products of the cement or to the coprecipitation of Co-hydroxide and Mg-hydroxide. In the other solutions the Co concentration is decreased by precipitation of Co-hydroxide due to the high pH value of 12.5, and the concentrations are comparable for the different solutions

  18. Root uptake of uranium (6) in solution by a higher plant: speciation in hydroponic solution, bioavailability, micro-localisation and biological effects induced

    International Nuclear Information System (INIS)

    Laroche, L.

    2005-01-01

    Uranium exists naturally in the environment, usually present in trace quantities. In soil solution and oxic conditions, uranium is present in the +VI oxidation state and forms a large number of inorganic and organic complexes. The exposure medium, an artificial soil solution, was designed in such a way as to control the uranium species in solution. The geochemical speciation code JCHESS was used to calculate the uranium aqueous species concentration and to define the domains of interest, each of them characterized by a limited number of dominant U species. These domains were defined as follows: pH 4.9 with uranyl ions as dominant species, pH 5.8 with hydroxyl complexes and pH 7 where carbonates play a major role. For each pH, short-duration (5 hours of exposure) well-defined laboratory experiments were carried out with Phaseolus vulgaris as plant model. The effect of competitive ions such as Ca 2+ or the presence of ligands such as phosphate or citrate on root assimilation efficiency was explored. Results have shown that uranium transfer was not affected by the presence of calcium, phosphate or citrate (but was decreased of 60% with citrate (10 μM) at pH 5.8) in our experimental conditions. Moreover, observation in Transmission Electronic Microscopy (TEM), equipped with an EDAX probe, have shown that uranium was associated with granules rich in phosphorus and that there were some chloroplast anomalies. Finally, the presence of uranium affects root CEC by reducing it and stimulates root elongation at low uranium concentrations (100 nM, 400 nM and 2 μM at pHs 4.9, 5.8 and 7 respectively) and inhibits it at high uranium concentrations. (author)

  19. Separation of uranium and rare earth elements from Rirang ore leach solution by two-step precipitation

    International Nuclear Information System (INIS)

    Sradjono; Erni Rifandriyah, A.; Zahardi

    1995-01-01

    Separation of uranium and rare-earth elements from Rirang ore leach solution was carried out through a two-step precipitation. Several condition affecting the separation processes were examined including solution pH, reagent concentration, and reaction prepitation time. Optimum conditions for the first and second precipitation steps include adjustment of precipitation pH to 1.3 and 2.3, respectively by the addition of 7.3% of NH 4 OH solution and allowing 60 minutes precipitation/reaction time. Based on the conditions, about 6% of Th, 3% of U, 0.9% of PO 4 3- , and none of RE were recovered in the first precipitation step meanwhile, about 99% of RE, 55% of U, 76% of PO 4 3- , and of the Th were recovered in the second step. (author). 3 refs. 4 tabs. 4 figs

  20. Dielectrophoresis Aligned Single-Walled Carbon Nanotubes as pH Sensors.

    Science.gov (United States)

    Li, Pengfei; Martin, Caleb M; Yeung, Kan Kan; Xue, Wei

    2011-01-31

    Here we report the fabrication and characterization of pH sensors using aligned single-walled carbon nanotubes (SWNTs). The SWNTs are dispersed in deionized (DI) water after chemical functionalization and filtration. They are deposited and organized on silicon substrates with the dielectrophoresis process. Electrodes with "teeth"-like patterns-fabricated with photolithography and wet etching-are used to generate concentrated electric fields and strong dielectrophoretic forces for the SWNTs to deposit and align in desired locations. The device fabrication is inexpensive, solution-based, and conducted at room temperature. The devices are used as pH sensors with the electrodes as the testing pads and the dielectrophoretically captured SWNTs as the sensing elements. When exposed to aqueous solutions with various pH values, the SWNTs change their resistance accordingly. The SWNT-based sensors demonstrate a linear relationship between the sensor resistance and the pH values in the range of 5-9. The characterization of multiple sensors proves that their pH sensitivity is highly repeatable. The real-time data acquisition shows that the sensor response time depends on the pH value, ranging from 2.26 s for the pH-5 solution to 23.82 s for the pH-9 solution. The long-term stability tests illustrate that the sensors can maintain their original sensitivity for a long period of time. The simple fabrication process, high sensitivity, and fast response of the SWNT-based sensors facilitate their applications in a wide range of areas.

  1. Characterization of aqueous silver nitrate solutions for leakage tests

    Directory of Open Access Journals (Sweden)

    José Ferreira Costa

    2011-06-01

    Full Text Available OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled and three brands of silver nitrate salt (Merck, Synth or Cennabras at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h and concentrations (1, 5, 25, 50% of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO3 solution and the primary teeth in 5% or 50% AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%. RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9. Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm. In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000. CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were

  2. Computer simulation of the effect of temperature on pH.

    Science.gov (United States)

    Kipp, J E; Schuck, D F

    1995-11-01

    The effect of temperature on solution pH was simulated by computer (program PHTEMP). We have determined that the change in pH due to shifts in acid-base equilibria [delta pH = pH(60 degrees C) - pH(25 degrees C)] can be substantial for compounds such as aliphatic amines that have high enthalpies for acid dissociation. This is of particular significance during elevated temperature experiments in which changes in the pKa values of formulation components, and hence the solution pH, can accelerate decomposition as compared to those formulations where sensitive functionality is absent. PHTEMP afforded the following results at initial pH = 7 (25 degrees C): (a) 0.1 M triethylamine (delta H zero = 10.4 kcal/mol) delta pH approximately -0.8; (b) 0.1 M acetic acid (delta H zero = -0.1 kcal/mol) delta pH approximately 0; (c) 0.1 M sulfuric acid (delta H zero 1 = -12 kcal/mol; delta H zero 2 = -5.4 kcal/mol) delta pH approximately -0.4. Solutions of general pharmaceutical interest were also studied and included a 12-component amino acid mixture, 0.1 M glycine, and 0.1 M triethylamine in either 0.02 M citric acid or 0.05 M TRIS buffer. In each case the pH change with temperature was dependent on the concentrations of components, the enthalpies for each acid dissociation, and the starting pH. At lower pH ( 9). These results are interpreted as the effect of a relative change in hydronium ion activity, delta H+/H+(initial), due to temperature-induced shifts in equilibria (acid dissociation, water autoprotolysis). This relative change must become larger as H+ decreases (pH increases). The output of PHTEMP was experimentally verified with 0.1 M glycine and with a multiple component amino acid solution. In both cases, agreement with prediction was excellent. The results of this investigation underscore the need to critically review formulation choices for both thermodynamic and traditional kinetic effects on the resulting product stability.

  3. Effect of Strength and Microstructure on Stress Corrosion Cracking Behavior and Mechanism of X80 Pipeline Steel in High pH Carbonate/Bicarbonate Solution

    Science.gov (United States)

    Zhu, Min; Du, Cuiwei; Li, Xiaogang; Liu, Zhiyong; Wang, Shengrong; Zhao, Tianliang; Jia, Jinghuan

    2014-04-01

    The stress corrosion cracking (SCC) behaviors and mechanisms of X80 pipeline steels with different strength and microstructure in high pH carbonate/bicarbonate solution were investigated by slow strain rate testing and electrochemical test. The results showed that the cracking mode of low strength X80 steel composed of bulky polygonal ferrite and granular bainite in high pH solution was intergranular (IGSCC), and the SCC mechanism was anodic dissolution (AD). While the mixed cracking mode of high strength X80 steel consisted of fine acicular ferrite and granular bainite was intergranular (IGSCC) in the early stage, and transgranular (TGSCC) in the later stage. The decrease of pH value of crack tip was probably the key reason for the occurrence of TGSCC. The SCC mechanism may be a mixed mode of AD and hydrogen embrittlement (HE), and the HE mechanism may play a significant role in the deep crack propagation at the later stage. The cracking modes and SCC mechanisms of the two X80 steels were associated with its microstructure and strength.

  4. Root uptake of uranium (6) in solution by a higher plant: speciation in hydroponic solution, bioavailability, micro-localisation and biological effects induced; Transfert racinaire de l'uranium (6) en solution chez une plante superieure: speciation en solution hydroponique, prise en charge par la plante, microlocalisation et effets biologiques induits

    Energy Technology Data Exchange (ETDEWEB)

    Laroche, L

    2005-01-15

    Uranium exists naturally in the environment, usually present in trace quantities. In soil solution and oxic conditions, uranium is present in the +VI oxidation state and forms a large number of inorganic and organic complexes. The exposure medium, an artificial soil solution, was designed in such a way as to control the uranium species in solution. The geochemical speciation code JCHESS was used to calculate the uranium aqueous species concentration and to define the domains of interest, each of them characterized by a limited number of dominant U species. These domains were defined as follows: pH 4.9 with uranyl ions as dominant species, pH 5.8 with hydroxyl complexes and pH 7 where carbonates play a major role. For each pH, short-duration (5 hours of exposure) well-defined laboratory experiments were carried out with Phaseolus vulgaris as plant model. The effect of competitive ions such as Ca{sup 2+} or the presence of ligands such as phosphate or citrate on root assimilation efficiency was explored. Results have shown that uranium transfer was not affected by the presence of calcium, phosphate or citrate (but was decreased of 60% with citrate (10 {mu}M) at pH 5.8) in our experimental conditions. Moreover, observation in Transmission Electronic Microscopy (TEM), equipped with an EDAX probe, have shown that uranium was associated with granules rich in phosphorus and that there were some chloroplast anomalies. Finally, the presence of uranium affects root CEC by reducing it and stimulates root elongation at low uranium concentrations (100 nM, 400 nM and 2 {mu}M at pHs 4.9, 5.8 and 7 respectively) and inhibits it at high uranium concentrations. (author)

  5. A highly selective chemosensor for colorimetric detection of Hg2+ and fluorescence detection of pH changes in aqueous solution

    International Nuclear Information System (INIS)

    Kavitha, Ramasamy; Stalin, Thambusamy

    2014-01-01

    A naturally existing and unmodified simple chemosensor, 2-hydroxy-1,4-naphthoquinone (2HNQ), was identified and used for both the colorimetric detection of Hg 2+ and the fluorescent (on-off) detection of pH. The distinct color change and quenching of fluorescence emission was visible to the naked eye. More importantly, the chemosensor was used in combination with β-cyclodextrin (β-CD), which enabled the sensor to be solubilized and stabilized in aqueous solutions. The sensor selectively detected Hg 2+ via the stable 1:1 complexation of the CåO and OH groups with Hg 2+ and reflected pH changes in the range from 6 to 12 via a fluorescence on–off response resulting from the deprotonation of the hydroxyl group in 2HNQ. - Highlights: • The 2-Hydroxy-1,4-Naphthoquinone (2HNQ) chemosensor is capable of both colorimetric detection of Hg 2+ and a fluorescence on-off response to pH. • The distinct color change and quenching of fluorescence emission are detectable with the naked eye. • The on– off fluorescence response in the pH range from 6– to 12 is due to the deprotonation of the hydroxyl group in 2HNQ

  6. The dissolution rate constant of magnetite in water at different temperatures and pH conditions

    International Nuclear Information System (INIS)

    Mohajery, Khatereh; Deydier de Pierrefeu, Laurent; Lister, Derek H.

    2012-09-01

    chemistry. For most determinations, a jet of water conditioned to the required chemistry but stripped of dissolved iron with ion-exchange is directed onto a pellet of magnetite and the dissolution monitored; the high velocity of the jet ensures that mass transfer effects are minimised. The magnetite is synthesised by a solid-state method involving heating a mixture of haematite and iron under vacuum at 600 deg. C, compacting under pressure and sintering into a pellet under argon at 1,100 deg. C. The product has an appropriate consistency and resistance to erosion. Most experiments have measured the average dissolution rate by estimating the amount of magnetite lost from the pellet by surface analysis and profilometry after exposure for a given time. Concomitant electrochemical information is obtained by electrically isolating the pellet from the loop and connecting it to a potentiostat, along with a counter-electrode and reference electrode strategically mounted in the loop test section. Detailed kinetic data are obtained by irradiating the magnetite before installation in the loop and monitoring on-line with gamma spectrometry the transport of dissolved, radioactive 59 Fe. Preliminary determinations had used radioactive magnetite precipitated under galvanostatic conditions from a solution of irradiated FeSO 4 in EDTA onto a platinum coupon. The coupon was then mounted axially in the loop test section and subjected to a range of imposed potentials during exposure; however, this coupon technique gave dissolution results confounded by the release of magnetite crystallites, so we concentrated on the pellet technique. The paper presents the results of exposures carried out over a range of temperatures and alkalinities at oxygen concentrations between 0 and 20 ppb. It shows how dissolution rate constants obtained under CANDU primary coolant conditions of 310 deg. C and pH 25C 10.5 (with LiOH) fall between published values, which were obtained with a different technique under

  7. Self-assembly behavior of pH- and thermosensitive amphiphilic triblock copolymers in solution: experimental studies and self-consistent field theory simulations.

    Science.gov (United States)

    Cai, Chunhua; Zhang, Liangshun; Lin, Jiaping; Wang, Liquan

    2008-10-09

    We investigated, both experimentally and theoretically, the self-assembly behaviors of pH- and thermosensitive poly(L-glutamic acid)- b-poly(propylene oxide)-b-poly(L-glutamic acid) (PLGA-b-PPO-b-PLGA) triblock copolymers in aqueous solution by means of transmission electron microscopy (TEM), scanning electron microscopy (SEM), dynamic light scattering (DLS), circular dichroism (CD), and self-consistent field theory (SCFT) simulations. Vesicles were observed when the hydrophilic PLGA block length is shorter or the pH value of solution is lower. The vesicles were found to transform to spherical micelles when the PLGA block length increases or its conformation changes from helix to coil with increasing the pH value. In addition, increasing temperature gives rise to a decrease in the size of aggregates, which is related to the dehydration of the PPO segments at higher temperatures. The SCFT simulation results show that the vesicles transform to the spherical micelles with increasing the fraction or statistical length of A block in model ABA triblock copolymer, which corresponds to the increase in the PLGA length or its conformation change from helix to coil in experiments, respectively. The SCFT calculations also provide chain distribution information in the aggregates. On the basis of both experimental and SCFT results, the mechanism of the structure change of the PLGA- b-PPO- b-PLGA aggregates was proposed.

  8. Redox properties of phenosafranine at zeolite-modified electrodes-Effect of surface modification and solution pH

    International Nuclear Information System (INIS)

    Easwaramoorthi, S.; Natarajan, P.

    2008-01-01

    Redox properties of cationic dye phenosafranine (3,7-diamino-5-phenylphenazenium chloride) (PS + ) were studied at zeolite-modified electrodes using Zeolite-Y and NaZSM-5. The peak current and peak potential of phenosafranine-adsorbed zeolite were found to be influenced by the pH of the electrolyte solution. Observation of a second redox couple is suggested to be due to formation of new species at low concentration from the reduced phenosafranine at the zeolite-modified electrodes. Titanium dioxide nanoparticles encapsulated in the cavities of the zeolite or anchored on the external surface of the zeolite do not seem to affect the redox properties of adsorbed PS + . When the cyclic voltammograms are recorded immediately after the electrode is immersed into the solution, the redox potential of PS + is found to be sensitive to the nature of the zeolite surface. The peak potential shifts towards positive region under continuous cycles as the surface hydroxyl groups get protonated in acidic electrolyte solution thereby forcing the movement of dye molecules from the zeolite surface to the zeolite electrode solution interface. The electron transfer rate constants for the adsorbed dye at the electrode are calculated to be 2.5 ± 0.2 s -1 and 3.5 ± 0.2 s -1 for the zeolite-Y electrode and the ZSM-5 electrode, respectively by the Laviron equation

  9. Recursive solution for dynamic response of one-dimensional structures with time-dependent boundary conditions

    Energy Technology Data Exchange (ETDEWEB)

    Abadi, Mohammad Tahaye [Aerospace Research Institute, Tehran (Iran, Islamic Republic of)

    2015-10-15

    A recursive solution method is derived for the transient response of one-dimensional structures subjected to the general form of time dependent boundary conditions. Unlike previous solution methods that assumed the separation of variables, the present method involves formulating and solving the dynamic problems using the summation of two single-argument functions satisfying the motion equation. Based on boundary and initial conditions, a recursive procedure is derived to determine the single-argument functions. Such a procedure is applied to the general form of boundary conditions, and an analytical solution is derived by solving the recursive equation. The present solution method is implemented for base excitation problems, and the results are compared with those of the previous analytical solution and the Finite element (FE) analysis. The FE results converge to the present analytical solution, although considerable error is found in predicting a solution method on the basis of the separation of variables. The present analytical solution predicts the transient response for wave propagation problems in broadband excitation frequencies.

  10. Recursive solution for dynamic response of one-dimensional structures with time-dependent boundary conditions

    International Nuclear Information System (INIS)

    Abadi, Mohammad Tahaye

    2015-01-01

    A recursive solution method is derived for the transient response of one-dimensional structures subjected to the general form of time dependent boundary conditions. Unlike previous solution methods that assumed the separation of variables, the present method involves formulating and solving the dynamic problems using the summation of two single-argument functions satisfying the motion equation. Based on boundary and initial conditions, a recursive procedure is derived to determine the single-argument functions. Such a procedure is applied to the general form of boundary conditions, and an analytical solution is derived by solving the recursive equation. The present solution method is implemented for base excitation problems, and the results are compared with those of the previous analytical solution and the Finite element (FE) analysis. The FE results converge to the present analytical solution, although considerable error is found in predicting a solution method on the basis of the separation of variables. The present analytical solution predicts the transient response for wave propagation problems in broadband excitation frequencies.

  11. Chemical Speciation and Bond Lengths of Organic Solutes by Core-Level Spectroscopy: pH and Solvent Influence on p-Aminobenzoic Acid.

    Science.gov (United States)

    Stevens, Joanna S; Gainar, Adrian; Suljoti, Edlira; Xiao, Jie; Golnak, Ronny; Aziz, Emad F; Schroeder, Sven L M

    2015-05-04

    Through X-ray absorption and emission spectroscopies, the chemical, electronic and structural properties of organic species in solution can be observed. Near-edge X-ray absorption fine structure (NEXAFS) and resonant inelastic X-ray scattering (RIXS) measurements at the nitrogen K-edge of para-aminobenzoic acid reveal both pH- and solvent-dependent variations in the ionisation potential (IP), 1s→π* resonances and HOMO-LUMO gap. These changes unequivocally identify the chemical species (neutral, cationic or anionic) present in solution. It is shown how this incisive chemical state sensitivity is further enhanced by the possibility of quantitative bond length determination, based on the analysis of chemical shifts in IPs and σ* shape resonances in the NEXAFS spectra. This provides experimental access to detecting even minor variations in the molecular structure of solutes in solution, thereby providing an avenue to examining computational predictions of solute properties and solute-solvent interactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Acid Rain, pH & Acidity: A Common Misinterpretation.

    Science.gov (United States)

    Clark, David B.; Thompson, Ronald E.

    1989-01-01

    Illustrates the basis for misleading statements about the relationship between pH and acid content in acid rain. Explains why pH cannot be used as a measure of acidity for rain or any other solution. Suggests that teachers present acidity and pH as two separate and distinct concepts. (RT)

  13. Effective degradation of rhodamine B by electro-Fenton process, using ferromagnetic nanoparticles loaded on modified graphite felt electrode as reusable catalyst: in neutral pH condition and without external aeration.

    Science.gov (United States)

    Tian, Jiangnan; Zhao, Jixiang; Olajuyin, Ayobami Matthew; Sharshar, Moustafa Mohamed; Mu, Tingzhen; Yang, Maohua; Xing, Jianmin

    2016-08-01

    Polytetrafluoroethylene/ferromagnetic nanoparticle/carbon black (PTFE/MNP/CB)-modified graphite felt (GF) was successfully applied as cathode for the mineralization of rhodamine B (RhB) in electro-Fenton (EF) process. The modified cathode showed high decolorization efficiency for RhB solution even in neutral pH condition and without external aeration, achieving nearly complete decolorization and 89.52 % total organic carbon (TOC) removal after 270-min oxidation with the MNP load 1.2 g at 50 A/m(2). Moreover, the operational parameters (current density, MNP load, initial pH, and airflow rate) were optimized. After that, adsorption isotherm was also conducted to compare the absorption quantity of CB and carbon nanotube (CNT). Then, the surface morphologies of MNPs were characterized by transmission electron microscope (TEM), energy-dispersive X-ray detector (EDX), and Fourier transform infrared spectroscopy (FTIR); and the modified cathode was characterized by SEM and contact angle. Finally, the stability and reusability of modified cathode were tested. Result uncovered that the PTFE/MNP/CB-modified cathode has the potential for industrial application and the solution after treatment was easily biodegradable.

  14. Synthesis and characterization of pH sensitive carboxySNARF-1 nanoreactors

    International Nuclear Information System (INIS)

    Chen Yenchi; Ostafin, Agnes; Mizukami, Hiroshi

    2010-01-01

    A rapid response dual wavelength emission pH sensor consisting of carboxySNARF-1 nanoreactors has been synthesized and shown to provide accurate pH measurements even in complex biological media, where the unprotected pH responsive dyes have failed. The carboxySNARF-1 nanoreactor is made of a calcium phosphate shell covering phosphatidylcholine liposomes filled with the dye. Its mean diameter is 150 nm with dynamic light scattering, the shell thickness is 5-7 nm with TEM, and it contains about 10 dyes/particle. The nanoreactor's response time to pH change nearly equals that of the dye in solution. Its pH titration curves at two different wavelengths are equivalent to those of the dye in solution and fluorescence intensity ratio dependent pH analysis is possible using the modified Henderson-Hasselbalch equation. However, the pH dependent fluorescence ratios of the dye in solution in the presence of plasma and albumin are distorted, and application of the Henderson-Hasselbalch equation is not possible. We have found that the distortions may be restored using cSNARF-1 nanoreactors and the pK a of the dye in the nanoreactor then equals that in solution. These results suggest that the interference to the dye for the pH analyses with the environmental molecules may be reduced or prohibited by usage of cSNARF-1 nanoreactors.

  15. Synthesis and characterization of pH sensitive carboxySNARF-1 nanoreactors

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yenchi; Ostafin, Agnes [Department of Materials Science, University of Utah, Salt Lake City, UT (United States); Mizukami, Hiroshi, E-mail: a.ostafin@utah.edu [Department of Biological Science, Wayne State University, Detroit, MI (United States)

    2010-05-28

    A rapid response dual wavelength emission pH sensor consisting of carboxySNARF-1 nanoreactors has been synthesized and shown to provide accurate pH measurements even in complex biological media, where the unprotected pH responsive dyes have failed. The carboxySNARF-1 nanoreactor is made of a calcium phosphate shell covering phosphatidylcholine liposomes filled with the dye. Its mean diameter is 150 nm with dynamic light scattering, the shell thickness is 5-7 nm with TEM, and it contains about 10 dyes/particle. The nanoreactor's response time to pH change nearly equals that of the dye in solution. Its pH titration curves at two different wavelengths are equivalent to those of the dye in solution and fluorescence intensity ratio dependent pH analysis is possible using the modified Henderson-Hasselbalch equation. However, the pH dependent fluorescence ratios of the dye in solution in the presence of plasma and albumin are distorted, and application of the Henderson-Hasselbalch equation is not possible. We have found that the distortions may be restored using cSNARF-1 nanoreactors and the pK{sub a} of the dye in the nanoreactor then equals that in solution. These results suggest that the interference to the dye for the pH analyses with the environmental molecules may be reduced or prohibited by usage of cSNARF-1 nanoreactors.

  16. Production of citrinin-free Monascus pigments by submerged culture at low pH.

    Science.gov (United States)

    Kang, Biyu; Zhang, Xuehong; Wu, Zhenqiang; Wang, Zhilong; Park, Sunghoon

    2014-02-05

    Microbial fermentation of citrinin-free Monascus pigments is of great interest to meet the demand of food safety. In the present work, the effect of various nitrogen sources, such as monosodium glutamate (MSG), cornmeal, (NH4)₂SO₄, and NaNO₃, on Monascus fermentation was examined under different initial pH conditions. The composition of Monascus pigments and the final pH of fermentation broth after Monascus fermentation were determined. It was found that nitrogen source was directly related to the final pH and the final pH regulated the composition of Monascus pigments and the biosynthesis of citrinin. Thus, an ideal nitrogen source can be selected to control the final pH and then the citrinin biosynthesis. Citrinin-free orange pigments were produced at extremely low initial pH in the medium with (NH4)₂SO₄ or MSG as nitrogen source. No citrinin biosynthesis at extremely low pH was further confirmed by extractive fermentation of intracellular pigments in the nonionic surfactant Triton X-100 micelle aqueous solution. This is the first report about the production of citrinin-free Monascus pigments at extremely low pH. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Potencial hidrogeniônico de soluções de cloridrato de dobutamina expostas a condições ambientais de unidades de cuidados intensivos neonatais Hydrogen-ion potential of dobutamine hydrochloride solutions exposed to environmental conditions of neonatal intensive care units

    Directory of Open Access Journals (Sweden)

    Lidiane L. Reis

    2009-12-01

    Full Text Available OBJETIVO: Verificar o potencial hidrogeniônico (pH de soluções de cloridrato de dobutamina sob condições ambientais que mimetizam unidades de cuidados intensivos neonatais. MÉTODOS: Analisou-se pH do fármaco em solução glicosada 5% ou NaCl 0,9% segundo temperatura (22 e 37 °C, luz (escuro, lâmpadas fluorescentes ambiente e equipamento de fototerapia e equipos (incolor e âmbar em intervalos de tempo (0, 1, 24, 48, 72 e 96 horas. RESULTADOS: Evidenciaram-se valores próximos de pH do fármaco na apresentação comercial e diluído. Obteve-se média de pH de 3,45±0,19 a 22 °C e de 3,55±0,20 a 37 °C. A média de pH das soluções mantidas no escuro foi de 3,62±0,09, na luz ambiente, de 3,63±0,07, e sob fototerapia, de 3,31±0,16. Soluções em equipos incolores tiveram média menor (3,41±0,24 do que em âmbares (3,52±0,15. Obtiveram-se menores valores de pH nas soluções sob fototerapia em equipos incolores (3,17±0,03 do que em âmbares (3,55±0,03. CONCLUSÃO: Sob a luz da fototerapia houve maior variação do pH das soluções, e o emprego de equipos âmbares minimizou tal efeito.OBJECTIVE: To verify the hydrogen-ion potential (pH of dobutamine hydrochloride solutions under environmental conditions similar to those of neonatal intensive care units. METHODS: We analyzed the pH of the drug diluted in 5% dextrose in water or 0.9% NaCl under different conditions of temperature (22 and 37 °C and light (dark, fluorescent light bulbs, and phototherapy equipment, using colorless and amber intravenous sets at time intervals of 0, 1, 24, 48, 72, and 96 hours. RESULTS: The pH values of the marketed form of the drug and the diluted drug were similar. The pH means were 3.45±0.19 at 22 °C and 3.55±0.20 at 37 °C. The average of the pH according to light conditions were as follows: in the dark = 3.62±0.09, under room light = 3.63±0.07, and exposed to phototherapy = 3.31±0.16. Solutions stored in colorless intravenous sets had a lower

  18. Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.

    Science.gov (United States)

    Kormalı Ertürün, H Elif; Demirel Özel, Ayça; Sayın, Serkan; Yılmaz, Mustafa; Kılıç, Esma

    2015-01-01

    A new pH sensing poly(vinyl chloride) (PVC) membrane electrode was developed by using recently synthesized 5,17-bis(4-benzylpiperidine-1-yl)methyl-25,26,27,28-tetrahydroxy calix[4]arene as an ionophore. The effects of membrane composition, inner filling solution and conditioning solution on the potential response of the proposed pH sensing membrane electrode were investigated. An optimum membrane composition of 3% ionophore, 67% o-nitrophenyl octyl ether (o-NPOE) as plasticizer, 30% PVC was found. The electrode exhibited a near-Nernstian slope of 58.7±1.1 mV pH(-1) in the pH range 1.9-12.7 at 20±1 °C. It showed good selectivity for H(+) ions in the presence of some cations and anions and a longer lifetime of at least 12 months when compared with the other PVC membrane pH electrodes reported in the literature. Having a wide working pH range, it was not only applied as a potentiometric indicator electrode in various acid-base titrations, but also successfully employed in different real samples. It has good reproducibility and repeatability with a response time of 6-7s. Compared to traditional glass pH electrode, it exhibited excellent potentiometric response after being used in fluoride-containing media. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Complexing agents and pH influence on chemical durability of type I moulded glass containers.

    Science.gov (United States)

    Biavati, Alberto; Poncini, Michele; Ferrarini, Arianna; Favaro, Nicola; Scarpa, Martina; Vallotto, Marta

    2017-06-16

    Among the factors that affect the glass surface chemical durability, pH and complexing agents presence in aqueous solution have the main role (1). Glass surface attack can be also related to the delamination issue with glass particles appearance in the pharmaceutical preparation. A few methods to check for glass containers delamination propensity and some control guidelines have been proposed (2,3). The present study emphasizes the possible synergy between a few complexing agents with pH on the borosilicate glass chemical durability. Hydrolytic attack was performed in small volume 23 ml type I glass containers autoclaved according to EP or USP for 1 hour at 121°C, in order to enhance the chemical attack due to time, temperature and the unfavourable surface/volume ratio. 0,048 M or 0.024 M (moles/liter) solutions of the acids citric, glutaric, acetic, EDTA (ethylenediaminetetraacetic acid) and sodium phosphate with water for comparison, were used for the trials. The pH was adjusted ± 0,05 units at fixed values 5,5-6,6-7-7,4-8-9 by LiOH diluted solution. Since silicon is the main glass network former, silicon release into the attack solutions was chosen as the main index of the glass surface attack and analysed by ICPAES. The work was completed by the analysis of the silicon release in the worst attack conditions, of moulded glass, soda lime type II and tubing borosilicate glass vials to compare different glass compositions and forming technologies. Surface analysis by SEM was finally performed to check for the surface status after the worst chemical attack condition by citric acid. Copyright © 2017, Parenteral Drug Association.

  20. Sorption of neptunium(V) on opalinus clay under aerobic/anaerobic conditions

    International Nuclear Information System (INIS)

    Froehlich, D.R.; Amayri, S.; Drebert, J.; Reich, T.

    2011-01-01

    The interaction between neptunium(V) and a natural argillaceous rock (Opalinus Clay (OPA), Mont Terri, Switzerland) has been investigated in batch sorption experiments by varying pH (6-10), Np(V) concentration (10 -12 -10 -4 M), solid-to-liquid ratio (2-20 g/L), and partial pressure of CO 2 (10 -3.5 and 10 -2.3 atm) under aerobic/anaerobic conditions in saturated calcite solution. All batch experiments were carried out using well characterized aerobic and anaerobic dry powders of OPA. The results show a great influence of pH on Np(V) sorption. Under aerobic conditions sorption increases with increasing pH until maximum sorption is reached between pH 8-9. At pH > 9 sorption decreases due to the formation of negatively charged Np(V)-carbonate complexes. By increasing p CO 2 from 10 -3.5 to 10 -2.3 atm, the sorption edge is shifted ∼ 0.5 units to lower pH values. Under anaerobic conditions stronger sorption of 8 x 10 -6 M Np(V) was found, possibly due to partial reduction of Np(V) to Np(IV). The sorption of 8 x 10 -6 M Np(V) under aerobic conditions at pH 8.2 in saturated calcite solution increases continuously with increasing solid-to-liquid ratio of OPA in the range of 2-20 g/L with a constant K d value of 126 ± 13 L/kg. The sorption isotherm was measured over seven orders of magnitude in Np(V) concentration using 239 Np as tracer. The sorption isotherm could be divided in a part of linear sorption behaviour between 10 -13 -10 -9 M Np(V) and non-linear behaviour in the range of 10 -9 -10 -4 M Np(V). (orig.)

  1. Influence of geometry of pipe on flow accelerated corrosion - a study under neutral pH condition

    International Nuclear Information System (INIS)

    Madasamy, P.; Mukunthan, M.; Chandramohan, P.; Krishna Mohan, T.V.; Velmurugan, S.; Sylvanus, Andrews; Natarajan, E.

    2015-01-01

    The carbon steel piping material's degradation due to flow accelerated corrosion (FAC) is one of the problems in nuclear power plant. FAC impacts plant operation and maintenance significantly. Wall thinning of structural materials should be predictable based on combined hydrodynamics analyses and experimental corrosion data. Such predictive tools help to take preventive measures before loss of material becomes a serious issue for plant operation. In order to develop predictive tools, data on the effect of various parameters that control FAC are required. As per existing literature, one of the important parameters that affect FAC is piping configuration (Geometry of flow path). Hence, experiments were carried out to assess the role played by the geometry of the piping in the FAC of carbon steel. In this study, experiments were conducted in simulation loop under neutral pH condition while varying the geometry parameter of bend such as bend angle and bend radius. Therefore, pipe specimen holder 15 NB bend with 58 °, 73 ° as bend angle and 4D, 2D bend radius was designed and fabricated. The experiments were carried out in order to quantify the wear rate (wall thickness measurement was by ultrasonic method) with a single phase flow velocity (7 m/s) under neutral pH conditions With the pipe specimen four experiments were conducted under neutral pH condition and at 120 DC. Wall thickness mapping was carried out by ultrasonic thickness gauge using a template before and after the experiment. High wall thickness reduction under neutral water chemistry enables easy measurement by ultrasonic thickness gauge. It was observed from the first two sets (2D 58°, 4D 58°) that the corrosion rate with 4D, 58 ° was 50% less than the corrosion with 2D 58°. Subsequently, another two sets of experiments (2D 73° and 4D 73°) was carried out in SIM loop at 7 m/s under neutral pH conditions for two months. Thus, this method of experiments enables us to understand the geometrical

  2. Dielectrophoresis Aligned Single-Walled Carbon Nanotubes as pH Sensors

    Directory of Open Access Journals (Sweden)

    Wei Xue

    2011-01-01

    Full Text Available Here we report the fabrication and characterization of pH sensors using aligned single-walled carbon nanotubes (SWNTs. The SWNTs are dispersed in deionized (DI water after chemical functionalization and filtration. They are deposited and organized on silicon substrates with the dielectrophoresis process. Electrodes with “teeth”-like patterns—fabricated with photolithography and wet etching—are used to generate concentrated electric fields and strong dielectrophoretic forces for the SWNTs to deposit and align in desired locations. The device fabrication is inexpensive, solution-based, and conducted at room temperature. The devices are used as pH sensors with the electrodes as the testing pads and the dielectrophoretically captured SWNTs as the sensing elements. When exposed to aqueous solutions with various pH values, the SWNTs change their resistance accordingly. The SWNT-based sensors demonstrate a linear relationship between the sensor resistance and the pH values in the range of 5–9. The characterization of multiple sensors proves that their pH sensitivity is highly repeatable. The real-time data acquisition shows that the sensor response time depends on the pH value, ranging from 2.26 s for the pH-5 solution to 23.82 s for the pH-9 solution. The long-term stability tests illustrate that the sensors can maintain their original sensitivity for a long period of time. The simple fabrication process, high sensitivity, and fast response of the SWNT-based sensors facilitate their applications in a wide range of areas.

  3. A combined experimental study of vivianite and As (V) reactivity in the pH range 2-11

    International Nuclear Information System (INIS)

    Thinnappan, V.; Merrifield, C.M.; Islam, F.S.; Polya, D.A.; Wincott, P.; Wogelius, R.A.

    2008-01-01

    Four different sets of experiments were completed in order to constrain vivianite [Fe 3 (PO 4 ) 2 . 8H 2 O] reactivity under conditions pertinent to As(V)-bearing groundwater systems. Firstly, titration experiments were undertaken in the pH range 4-9 to determine the zero point of charge (ZPC) of vivianite; showing that the ZPC lies at a pH of approximately 5.3. Secondly, the steady state dissolution rates of vivianite far from equilibrium were measured in aqueous solutions in the pH range 2-10 at 18.5 d eg. C (±3 deg. C) using a fluidized bed reactor. The rate of vivianite dissolution, R, is given by (1)R(moless -1 cm -2 )=1.18x10 -10 a H+ 0.77 +1x10 -15 +6.92x10 -24 a H+ -1 The dissolution rate exhibits an exponential increase with increase in the activity of the H + ion (a H+ ) in solution at 2 8. Thirdly, the sorption of arsenate [As(V)] onto natural well-crystallized vivianite in the pH range 3-11 under static flow conditions was determined. 25-40% of As(V) from a starting concentration (C 0 ) of 100 μM was adsorbed onto vivianite. Static adsorption experiments were also completed at two lower As(V) concentrations (C 0 = 10 and 1 μM). Sorption was determined to be only weakly dependent on pH. Fourthly, the final part of this study investigated the sorption of As(V) onto vivianite at pH 9 under dynamic flow conditions. An input solution of 4 mM As(V) was applied to water saturated columns, followed by leaching with deionised water (DIW). Breakthrough curves show that the retention and exchangeability of As within the column is enhanced with vivianite present, consistent with solid phase analysis of unreacted and reacted solid materials. A simple calculation based on a model shallow Bengal sediment having about 0.2 wt% of vivianite and total initial dissolved As concentrations of 100 μM showed that under such conditions 88% of dissolved As(V) could potentially be adsorbed onto vivianite. These results will help to better understand As mobility in the

  4. Determining pH of strip-mine spoils

    Science.gov (United States)

    W. A. Berg

    1969-01-01

    Results with the LaMotte-Morgan method for determining soil pH-or the solution modification of this method-usually agreed fairly well with the results from using a pH meter, the recognized standard. Results obtained with the Soiltex and Hellige-Truog methods often deviated somewhat from the pH meter readings; and the Hydrion papers and the Kelway pH tester often gave...

  5. A pH dependent Raman and surface enhanced Raman spectroscopic studies of citrazinic acid aided by theoretical calculations

    Science.gov (United States)

    Sarkar, Sougata; Chowdhury, Joydeep; Dutta, Soumen; Pal, Tarasankar

    2016-12-01

    A pH dependent normal Raman scattering (NRS) and surface enhanced Raman scattering (SERS) spectral patterns of citrazinic acid (CZA), a biologically important molecule, have been investigated. The acid, with different pKa values ( 4 and 11) for the two different functional groups (-COOH and -OH groups), shows interesting range of color changes (yellow at pH 14 and brown at pH 2) with the variation in solution pH. Thus, depending upon the pH of the medium, CZA molecule can exist in various protonated and/or deprotonated forms. Here we have prescribed the existence different possible forms of CZA at different pH (Forms ;C;, ;H; and ;Dprot; at pH 14 and Forms ;A;, ;D;, and ;P; at pH 2 respectively). The NRS spectra of these solutions and their respective SERS spectra over gold nanoparticles were recorded. The spectra clearly differ in their spectral profiles. For example the SERS spectra recorded with the CZA solution at pH 2 shows blue shift for different bands compared to its NRS window e.g. 406 to 450 cm- 1, 616 to 632 cm- 1, 1332 to 1343 cm- 1 etc. Again, the most enhanced peak at 1548 cm- 1 in NRS while in the SERS window this appears at 1580 cm- 1. Similar observation was also made for CZA at pH 14. For example, the 423 cm- 1 band in the NRS profile experience a blue shift and appears at 447 cm- 1 in the SERS spectrum as well as other bands at 850, 1067 and 1214 cm- 1 in the SERS window are markedly enhanced. It is also worth noting that the SERS spectra at the different pH also differ from each other. These spectral differences indicate the existence of various adsorptive forms of the CZA molecule depending upon the pH of the solution. Therefore based on the experimental findings we propose different possible molecular forms of CZA at different pH (acidic and alkaline) conditions. For example forms 'A', 'D' and 'P' existing in acidic pH (pH 2) and three other deprotonated forms 'C', 'H' and 'Dprot' in alkaline pH (pH 14). The DFT calculations for these

  6. Changes in soil solution Zn and pH and uptake of Zn by arbuscular mycorrhizal red clover in Zn-contaminated soil.

    Science.gov (United States)

    Li, X; Christie, P

    2001-01-01

    Red clover plants inoculated with Glomus mosseae were grown in a sterile pasture soil containing 50 mg Zn kg(-1) in 'Plexiglas' (acrylic) containers with nylon net partitions (30 microm mesh) designed to separate the soil into a central root zone and two outer zones for hyphal growth with no root penetration. Two porous plastic soil moisture samplers were installed in each pot, one in the root compartment and the other in one of the hyphal compartments. The soil in the outer compartments was amended with one of the four application rates of Zn (as ZnSO4) ranging from 0 to 1000 mg kg(-1). Non-mycorrhizal controls were included, and there were five replicates of each treatment in a randomised block in a glasshouse. Uninoculated plants received supplementary P to avoid yield limitation due to low soil P status. Plants grew in the central compartment for nine weeks. Soil moisture samples were collected 4, 24 and 62 days after sowing to monitor changes in the Zn concentration and pH of the soil solution. At harvest, the mean mycorrhizal infection rate of inoculated plants ranged from 29% to 34% of total root length and was little affected by Zn application. Root and shoot yields were not affected by mycorrhizal infection. Plant Zn concentration and uptake were lower in mycorrhizal plants than non-mycorrhizal controls, and this effect was more pronounced with increasing Zn application rate to the soil. Soil solution Zn concentrations were lower and pH values were higher in mycorrhizal treatments than non-mycorrhizal controls and the mycorrhiza effect was more pronounced at higher Zn application rates. The protective effect of mycorrhiza against plant Zn uptake may have been associated with changes in Zn solubility mediated by changes in the soil solution pH, or by immobilisation of Zn in the extraradical mycelium.

  7. Technetium recovery from high alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  8. Surface sulfonamide modification of poly(N-isopropylacrylamide)-based block copolymer micelles to alter pH and temperature responsive properties for controlled intracellular uptake.

    Science.gov (United States)

    Cyphert, Erika L; von Recum, Horst A; Yamato, Masayuki; Nakayama, Masamichi

    2018-06-01

    Two different surface sulfonamide-functionalized poly(N-isopropylacrylamide)-based polymeric micelles were designed as pH-/temperature-responsive vehicles. Both sulfadimethoxine- and sulfamethazine-surface functionalized micelles were characterized to determine physicochemical properties, hydrodynamic diameters, zeta potentials, temperature-dependent size changes, and lower critical solution temperatures (LCST) in both pH 7.4 and 6.8 solutions (simulating both physiological and mild low pH conditions), and tested in the incorporation of a proof-of-concept hydrophobic antiproliferative drug, paclitaxel. Cellular uptake studies were conducted using bovine carotid endothelial cells and fluorescently labeled micelles to evaluate if there was enhanced cellular uptake of the micelles in a low pH environment. Both variations of micelles showed enhanced intracellular uptake under mildly acidic (pH 6.8) conditions at temperatures slightly above their LCST and minimal uptake at physiological (pH 7.4) conditions. Due to the less negative zeta potential of the sulfamethazine-surface micelles compared to sulfadimethoxine-surface micelles, and the proximity of their LCST to physiological temperature (37°C), the sulfamethazine variation was deemed more amenable for clinically relevant temperature and pH-stimulated applications. Nevertheless, we believe both polymeric micelle variations have the capacity to be implemented as an intracellular drug or gene delivery system in response to mildly acidic conditions. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1552-1560, 2018. © 2018 Wiley Periodicals, Inc.

  9. Sugar-based gemini surfactant with a vesicle-to-micelle transition at acidic pH and a reversible vesicle flocculation near neutral pH

    NARCIS (Netherlands)

    Johnsson, M; Wagenaar, A; Engberts, JBFN

    2003-01-01

    A sugar-based (reduced glucose) gemini surfactant forms vesicles in dilute aqueous solution near neutral pH. At lower pH, there is a vesicle-to-micelle transition within a narrow pH region (pH 6.0-5.6). The vesicles are transformed into large cylindrical micelles that in turn are transformed into

  10. Emulsion properties of pork myofibrillar protein in combination with microbial transglutaminase and calcium alginate under various pH conditions.

    Science.gov (United States)

    Hong, Geun Pyo; Min, Sang-Gi; Chin, Koo Bok

    2012-01-01

    In this study, the effects of microbial transglutaminase (MTG) and calcium alginate (CA) systems in combination with soybean oil on the emulsion properties of porcine myofibrillar protein (MP) were evaluated under various pH conditions. MTG was shown to improve emulsifying capacity and creaming stability, which increased with increasing pH values up to 6.5. The CA did not influence emulsifying capacity, but it improved the creaming stability of the MP-stabilized emulsions. Both MTG and CA enhanced the rheological properties, but their effects on the physical characteristics of the protein evidenced an opposite trend in relation to pH, i.e., the MTG system improved both the emulsion and gelling properties with increasing pH, whereas the CA system was effective when the pH was lowered. By combining the two MP gelling systems, a stable and pH-insensible emulsion could be produced. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Did Life Emerge in Thermo-Acidic Conditions?

    Science.gov (United States)

    Holmes, D. S.

    2017-12-01

    There is widespread, but not unanimous, agreement that life emerged in hot conditions by exploiting redox and pH disequilibria found on early earth. Although there are several hypotheses to explain the postulated pH disequilibria, few of these consider that life evolved at very low pH (biological evolution. This presentation will evaluate the pros and cons of the hypothesis that the early evolution of life occurred in thermo-acidic conditions. Such environments are thought to have been abundant on early earth and were probably rich in hydrogen and soluble metals including iron and sulfur that could have served as sources and sinks of electrons. Extant thermo-acidophiles thrive in such conditions. Low pH environments are rich in protons that are the major drivers of energy conservation by coupling to phosphorylation in virtually all organisms on earth; this may be a "biochemical fossil" reflecting the use of protons (low pH) in primitive energy conservation. It has also been proposed that acidic conditions favored the evolution of an RNA world with expanded catalytic activities. On the other hand, the idea that life emerged in thermo-acidic conditions can be challenged because of the proposed difficulties of folding and stabilizing proteins simultaneously exposed to high temperature and low pH. In addition, although thermo-acidophiles root to the base of the phylogenetic tree of life, consistent with the proposition that they evolved early, yet there are problems of interpretation of their subsequent evolution that cloud this simplistic phylogenetic view. We propose solutions to these problems and hypothesize that life evolved in thermo-acidic conditions.

  12. Study of the crystallographic phase change on copper (I) selenide thin films prepared through chemical bath deposition by varying the pH of the solution

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval-Paz, M.G., E-mail: myrnasandoval@udec.cl [Departament of Physics, Faculty of Physical Sciences and Mathematics, University of Concepcion, Box 160-C, Concepción (Chile); Rodríguez, C.A. [Department of Materials Engineering, Faculty of Engineering, University of Concepción, Edmundo Larenas 270, Concepción 4070409 (Chile); Porcile-Saavedra, P.F. [Departament of Physics, Faculty of Physical Sciences and Mathematics, University of Concepcion, Box 160-C, Concepción (Chile); Trejo-Cruz, C. [Department of Physics, Faculty of Science, University of Biobío, Avenue Collao 1202, Box 5C, Concepción 4051381 (Chile)

    2016-07-15

    Copper (I) selenide thin films with orthorhombic and cubic structure were deposited on glass substrates by using the chemical bath deposition technique. The effects of the solution pH on the films growth and subsequently the structural, optical and electrical properties of the films were studied. Films with orthorhombic structure were obtained from baths wherein both metal complex and hydroxide coexist; while films with cubic structure were obtained from baths where the metal hydroxide there is no present. The structural modifications are accompanied by changes in bandgap energy, morphology and electrical resistivity of the films. - Graphical abstract: “Study of the crystallographic phase change on copper (I) selenide thin films prepared through chemical bath deposition by varying the pH of the solution” by M. G. Sandoval-Paz, C. A. Rodríguez, P. F. Porcile-Saavedra, C. Trejo-Cruz. Display Omitted - Highlights: • Copper (I) selenide thin films were obtained by chemical bath deposition. • Orthorhombic to cubic phase change was induced by varying the reaction solution pH. • Orthorhombic phase is obtained mainly from a hydroxides cluster mechanism. • Cubic phase is obtained mainly from an ion by ion mechanism. • Structural, optical and electrical properties are presented as a function of pH.

  13. Effects of phytoextraction on heavy metal concentrations and pH of pore-water of biosolids determined using an in situ sampling technique.

    Science.gov (United States)

    Huynh, T T; Laidlaw, W S; Singh, B; Gregory, D; Baker, A J M

    2008-12-01

    Heavy metal concentrations and pH of pore-water in contaminated substrates are important factors in controlling metal uptake by plants. We investigated the effects of phytoextraction on these properties in the solution phase of biosolids and diluted biosolids in a 12-month phytoextraction column experiment. Phytoextraction using Salix and Populus spp. temporarily decreased pore-water pH of the substrates over the experimental period followed by a return to initial pH conditions. Salixxreichardtii and Populus balsamifera effectively extracted Ni, Zn and Cd and actively mobilized these metals from the solid to the solution phase. S.xreichardtii had the stronger effect on mobilization of metals due to its larger root system. Phytoextraction did not affect Cu in the solution phase of the biosolids. Heavy metals were leached down to lower depths of the columns during the phytoextraction process.

  14. Bifurcation of positive solutions to scalar reaction-diffusion equations with nonlinear boundary condition

    Science.gov (United States)

    Liu, Ping; Shi, Junping

    2018-01-01

    The bifurcation of non-trivial steady state solutions of a scalar reaction-diffusion equation with nonlinear boundary conditions is considered using several new abstract bifurcation theorems. The existence and stability of positive steady state solutions are proved using a unified approach. The general results are applied to a Laplace equation with nonlinear boundary condition and bistable nonlinearity, and an elliptic equation with superlinear nonlinearity and sublinear boundary conditions.

  15. Metal/Metal Oxide Differential Electrode pH Sensors

    Science.gov (United States)

    West, William; Buehler, Martin; Keymeulen, Didier

    2007-01-01

    Solid-state electrochemical sensors for measuring the degrees of acidity or alkalinity (in terms of pH values) of liquid solutions are being developed. These sensors are intended to supplant older electrochemical pH sensors that include glass electrode structures and reference solutions. The older sensors are fragile and subject to drift. The present developmental solid-state sensors are more rugged and are expected to be usable in harsh environments. The present sensors are based on a differential-electrode measurement principle. Each sensor includes two electrodes, made of different materials, in equilibrium with the solution of interest.

  16. Influence of storage solution on enamel demineralization submitted to pH cycling Influência da solução de armazenagem na desmineralização do esmalte submetido à ciclagem de pH

    Directory of Open Access Journals (Sweden)

    Juliana Silva Moura

    2004-09-01

    Full Text Available Extracted human teeth are frequently used for research or educational purposes. Therefore, it is necessary to store them in disinfectant solutions that do not alter dental structures. Thus, this study evaluated the influence of storage solution on enamel demineralization. For that purpose, sixty samples were divided into the following groups: enamel stored in formaldehyde (F1, stored in thymol (T1, stored in formaldehyde and submitted to pH cycling (F2, stored in thymol and submitted to pH cycling (T2. All samples were evaluated by cross-sectional microhardness analysis and had their percentage of mineral volume versus micrometer (integrated area determined. Differences between groups were found up to 30-µm depth from the enamel surface (p Dentes humanos extraídos são freqüentemente utilizados para propósitos educacionais ou de pesquisa. Desta forma, é necessário o armazenamento dos mesmos em soluções desinfetantes que não alterem a estrutura dental. Para tanto, sessenta espécimes foram divididos nos seguintes grupos: esmalte armazenado em formol (F1, armazenado em timol (T1, armazenado em formol e submetido à ciclagem de pH (F2 e armazenado em timol e submetido à ciclagem de pH (T2, sendo avaliados por meio de análise de microdureza longitudinal e tiveram a porcentagem de volume mineral pro micrômetro determinada. Diferenças entre os grupos foram encontradas até a profundidade de 30µm da superfície do esmalte (p<0,05, onde o grupo mais desmineralizado era T2. Foi concluído que a solução de armazenagem influenciou na reação do substrato dental a um desafio cariogênico, sugerindo que o formaldeído pode aumentar a resistência do esmalte à desmineralização promovida pelo modelo de ciclagem de pH, quando comparado à desmineralização ocorrida no esmalte armazenado em timol.

  17. Direct measurement of CO2 solubility and pH in NaCl hydrothermal solutions by combining in-situ potentiometry and Raman spectroscopy up to 280 °C and 150 bar

    Science.gov (United States)

    Truche, Laurent; Bazarkina, Elena F.; Berger, Gilles; Caumon, Marie-Camille; Bessaque, Gilles; Dubessy, Jean

    2016-03-01

    The in-situ monitoring of aqueous solution chemistry at elevated temperatures and pressures is a major challenge in geochemistry. Here, we combined for the first time in-situ Raman spectroscopy for concentration measurements and potentiometry for pH measurement in a single hydrothermal cell equipped with sampling systems and operating under controlled conditions of temperature and pressure. Dissolved CO2 concentration and pH were measured at temperatures up to 280 °C and pressures up to 150 bar in the H2O-CO2 and H2O-CO2-NaCl systems. A Pitzer specific-ion-interaction aqueous model was developed and confirmed the accuracy and consistency of the measurements, at least up to 250 °C. The revised Pitzer parameters for the H2O-CO2-NaCl system were formatted for the Phreeqc geochemical software. Significant changes with respect to the Pitzer.dat database currently associated with Phreeqc were observed. The new model parameters are now available for further applications. The Raman and pH probes tested here may also be applied to field monitoring of hydrothermal springs, geothermal wells, and oil and gas boreholes.

  18. Nontrivial Solution of Fractional Differential System Involving Riemann-Stieltjes Integral Condition

    Directory of Open Access Journals (Sweden)

    Ge-Feng Yang

    2012-01-01

    differential system involving the Riemann-Stieltjes integral condition, by using the Leray-Schauder nonlinear alternative and the Banach contraction mapping principle, some sufficient conditions of the existence and uniqueness of a nontrivial solution of a system are obtained.

  19. Influence of pH, temperature, and concentration on stabilization of aqueous hornet silk solution and fabrication of salt-free materials.

    Science.gov (United States)

    Kameda, Tsunenori

    2015-01-01

    We found that an aqueous solution of silk from cocoons produced by hornet larvae (hornet silk) can be obtained when the solution is adjusted to basic conditions of pH > 9.2. It is known that native hornet cocoons can be dissolved in concentrated aqueous solution of salts, such as lithium bromide (LiBr) and calcium chloride (CaCl2). Upon the removal of these salts from solution by dialysis, solidification, gelation, or sedimentation of hornet silk is known to occur. In the present study, under basic conditions, however, no such solidification occurred, even after salt removal. In this study, ammonia was used for alkalization of solution because it is volatilized during the casting process and pure hornet silk materials can be obtained after drying. The effects of the concentrations of hornet silk and ammonia, as well as dialysis temperature, on preventing gelation during dialysis were investigated. Dialysis conditions that limit the degradation of hornet silk by hydrolysis in alkali solution were identified. Moreover, casting conditions to prepare flexible and transparent hornet silk film from aqueous ammonia solution were optimized. Molecular structural analysis of hornet silk in aqueous ammonia solution and cast film indicated the formation of α-helix conformations. © 2014 Wiley Periodicals, Inc.

  20. Traceability of pH to the Mole

    Directory of Open Access Journals (Sweden)

    Maria Filomena Camões

    2015-08-01

    Full Text Available Free acidity of aqueous solutions was initially defined in 1909 by Søren Peter Lauritz Sørensen as pH = −lgcH+ (c/mol·dm−3 or m/mol·kg−1 of the free hydrogen ions in solution, H+ soon (1910 was changed to pH = paH+ = −lgaH+, integrating the new concepts of activity, ai and activity coefficient γi, for the ionic species i under concern, H+ in this case; it is ai = −lg(miγi. Since individual ions do not exist alone in solution, primary pH values cannot be assigned solely by experimental measurements, requiring extra thermodynamic model assumptions for the activity coefficient, γH+, which has put pH in a unique situation of not being fully traceable to the International System of Units (SI. Also the concept of activity is often not felt to be as perceptible as that of concentration which may present difficulties, namely with the interpretation of data. pH measurements on unknown samples rely on calibration of the measuring setup with adequate reference pH buffers. In this work, the assignment of pH values to buffers closely matching the samples, e.g., seawater, is revisited. An approach is presented to assess the quantity pmH+ = −lgmH+ profiting from the fact that, contrary to single ion activity coefficients, mean activity coefficients,   can be assessed based on experimentally assessed quantities alone, γExp ±, thus ensuring traceability to the mole, the SI base unit for amount of substance. Compatibility between γExp ± and mean activity coefficient calculated by means of Pitzer model equations, γPtz ±, validates the model for its intended use.

  1. Recovery of uranium from sulphate solutions containing molybdenum

    International Nuclear Information System (INIS)

    Weir, D.R.; Genik-Sas-Berezowsky, R.M.

    1983-01-01

    A process for recovering uranium from a sulphate solution containing dissolved uranium and molybdenum includes reacting the solution with ammonia (pH 8 to 10), the pH of the original solution must not exceed 5.5 and after the addition of ammonia the pH must not be in the vicinity of 7 for a significant time. The resultant uranium precipitate is relatively uncontaminated by molybdenum. The precipitate is then separated from the remaining solution while the pH is maintained within the stated range

  2. An All-Solid-State pH Sensor Employing Fluorine-Terminated Polycrystalline Boron-Doped Diamond as a pH-Insensitive Solution-Gate Field-Effect Transistor.

    Science.gov (United States)

    Shintani, Yukihiro; Kobayashi, Mikinori; Kawarada, Hiroshi

    2017-05-05

    A fluorine-terminated polycrystalline boron-doped diamond surface is successfully employed as a pH-insensitive SGFET (solution-gate field-effect transistor) for an all-solid-state pH sensor. The fluorinated polycrystalline boron-doped diamond (BDD) channel possesses a pH-insensitivity of less than 3mV/pH compared with a pH-sensitive oxygenated channel. With differential FET (field-effect transistor) sensing, a sensitivity of 27 mv/pH was obtained in the pH range of 2-10; therefore, it demonstrated excellent performance for an all-solid-state pH sensor with a pH-sensitive oxygen-terminated polycrystalline BDD SGFET and a platinum quasi-reference electrode, respectively.

  3. A novel fluorescence probe based on triphenylamine Schiff base for bioimaging and responding to pH and Fe3+

    International Nuclear Information System (INIS)

    Wang, Lei; Yang, Xiaodong; Chen, Xiuli; Zhou, Yuping; Lu, Xiaodan; Yan, Chenggong; Xu, Yikai; Liu, Ruiyuan; Qu, Jinqing

    2017-01-01

    A novel fluorescence probe 1 based on triphenylamine was synthesized and characterized by NMR, IR, high resolution mass spectrometry and elemental analysis. Its fluorescence was quenched when pH below 2. There was a linear relationship between the fluorescence intensity and pH value ranged from 2 to 7. And its fluorescence emission was reversibility in acidic and alkaline solution. Furthermore, it exhibited remarkable selectivity and high sensitivity to Fe 3+ and was able to detect Fe 3+ in aqueous solution with low detection limit of 0.511 μM. Job plot showed that the binding stoichiometry of 1 with Fe 3+ was 1:1. Further observations of 1 H NMR titration suggested that coordination interaction between Fe 3+ and nitrogen atom on C =N bond promoted the intramolecular charge transfer (ICT) or energy transfer process causing fluorescence quenching. Additionally, 1 was also able to be applied for detecting Fe 3+ in living cell and bioimaging. - Graphical abstract: Triphenylamine based fluorescence probe can detect pH and Fe 3+ simultaneously in aqueous solution and be applied for detecting Fe 3+ in living cell and bioimaging. - Highlights: • The fluorescence probe is sensitive to pH in strong acid conditions. • The fluorescence chemosensor can detect pH and Fe 3+ simultaneously. • The recognition is able to carry out in aqueous solution. • The probe can also be applied for detecting Fe 3+ in living cell and bioimaging. • The sensor is synthesized easily with one step.

  4. On the physical solutions to the heat equation subjected to nonlinear boundary conditions

    International Nuclear Information System (INIS)

    Gama, R.M.S. da.

    1990-01-01

    This work consists of a discussion on the physical solutions to the steady-state heat transfer equation, when it is subjected to nonlinear boundary conditions. It will be presented a functional, whose minimum occurs for the (unique) physical solution to the condidered heat transfer problem, suitable for a large class of typical (nonlinear) boundary conditions (representing the radiative/convective loss from the body to the environment). It will be demonstrated that these problems admit-always one, and only one, physical solution (which represents the absolute temperature). (author)

  5. Electrochemical studies of the corrosion behavior of a low-carbon steel in aqueous chloride solutions simulating accident conditions of radioactive waste disposal

    International Nuclear Information System (INIS)

    Farvaque-Bera, A.M.; Leistikow, S.

    1991-01-01

    The fine-grained structural steel DIN W.Nr. 1.0566 was exposed to various sulfate and chloride-containing aqueous solutions, the latter ones simulating the potential accidental environment of water intrusion into a salt mine. By electrochemical measurements in salt brines, the following results were achieved: (1) The corrosion rate is highly dependent on salt brine composition, pH and temperature. (2) Active metal dissolution led to formation of shallow pits as surface corrosion phenomenon. Thus, the application of electrochemical techniques - under non-polarized as well as under potentiodynamic conditions - proved to be suitable for fast qualitative testing of the influence of various environmental parameters on steel corrosion. (orig.)

  6. Dissolution study of tremolite and anthophyllite: pH effect on the reaction kinetics

    International Nuclear Information System (INIS)

    Rozalen, M.; Ramos, M.E.; Gervilla, F.; Kerestedjian, T.; Fiore, S.; Huertas, F.J.

    2014-01-01

    Highlights: • Dissolution rates strongly depend on pH and it is different for each mineral. • Anthophyllite dissolves up to 8 times faster than tremolite in similar conditions. • SEM images show different particle breakage and carbonation effects at basic pHs. • Our results are a good background to develop remediation processes of contaminated sites. - Abstract: The effect of pH on the kinetics of tremolite and anthophyllite dissolution was investigated at 25 °C in batch reactors over the pH range of 1–13.5, in inorganic buffered solutions. Dissolution rates were obtained based on the release of Si and Mg. Results obtained in this study show different behaviors for both minerals. For tremolite, dissolution rates show a noticeable dependence on pH between 1 and 8, decreasing as pH increases and reaching a minimum around neutral conditions. At basic pH this dependence becomes even stronger, but dissolution takes place together with collateral effects of saturation and carbonation. A preferential release of Ca and Mg is observed in acid media, lowering the Mg/Si ratio to the extent that Mg solubility decreases with pH. For anthophyllite, dissolution rates also show a strong dependence on pH, between 1 and 9.5. At the same pH, anthophyllite dissolves up to 8 times faster than tremolite. For pH > 9.5 this dependence is smooth, and it is probably associated with effects of saturation and carbonation. Dissolution is also non-stoichiometric with a faster release of Mg with respect to Si in acid media. SEM observations show differences in the breakage mechanism of the fibers. The anthophyllite particle breakage during dissolution consists of the splitting of bundle fibers parallel to the fiber longitudinal direction. However, for tremolite, other than fiber splitting, particles shorten induced by coalescence of etch pits developed perpendicular to c axe

  7. Effects of cell condition, pH, and temperature on lead, zinc, and copper sorption to Acidithiobacillus caldus strain BC13

    International Nuclear Information System (INIS)

    Aston, John E.; Apel, William A.; Lee, Brady D.; Peyton, Brent M.

    2010-01-01

    Research highlights: →At. caldus sorbs lead, zinc, and copper across a range of pH and temperature. →At. caldus shows a relatively high sorption capacity for zinc and copper at low pH. → Lead, zinc, and copper sorption decreases in tertiary mixtures. → Copper appears to sorb via a different mechanism(s) than lead or zinc. - Abstract: This study describes the effects of cell condition, pH, and temperature on lead, zinc, and copper sorption to Acidithiobacillus caldus strain BC13 with a Langmuir model. Copper exhibited the highest loading capacity, 4.76 ± 0.28 mmol g -1 , to viable cells at pH 5.5. The highest k L (binding-site affinity) observed was 61.2 ± 3.0 L mmol -1 to dehydrated cells at pH 4.0. The pHs that maximized loading capacities and binding-site affinities were generally between 4.0 and 5.5, where the sum of free-proton and complexed-metal concentrations was near a minimum. Of additional importance, lead, zinc, and copper sorbed to viable cells at pH values as low as 1.5. Previous studies with other acidithiobacilli did not measure viable-cell sorption below pH 4.0. In separate experiments, desorption studies showed that far less copper was recovered from viable cells than any other metal or cell condition, suggesting that uptake may play an important role in copper sorption by At. caldus strain BC13. To reflect an applied system, the sorption of metal mixtures was also studied. In these experiments, lead, zinc, and copper sorption from a tertiary mixture were 40.2 ± 4.3%, 28.7 ± 3.8%, and 91.3 ± 3.0%, respectively, of that sorbed in single-metal systems.

  8. Investigation of some critical parameters of buffer conditions for the development of quantum dots-based optical sensors

    International Nuclear Information System (INIS)

    Yuan Jipei; Guo Weiwei; Wang Erkang

    2008-01-01

    The unique surface-sensitive properties make quantum dots (QDs) great potential in the development of sensors for various analytes. However, quantum dots are not only sensitive to a certain analyte, but also to the surrounding conditions. The controlled response to analyte may be the first step in the designing of functional quantum dots sensors. In this study, taking the quenching effect of benzoquinone (BQ) on CdTe QDs as model, several critical parameters of buffer solution conditions with potential effect on the sensors were investigated. The pH value and the concentration of sodium citrate in the buffer solution critically influenced the quenching effects of BQ. Dozens folds elevation of the quenching extents were observed with the increase of concentrations of H + and sodium citrate, and the quenching mechanisms were also fundamentally different with the changes of the surrounding buffer solutions. The quenching models were proposed and analyzed at different buffer conditions. Taking pH values for example, QDs quenching obeyed the sphere of effective quenching model with the sphere radii of 8.29 nm at pH 8.0, the linear Stern-Volmer equation with Stern-Volmer constant of 2.0 x 10 3 mol -1 L at pH 7.0, and the two binding site static quenching model at basic conditions. The elucidation of parameters for assay performance was important in the development of QDs-based optical sensors

  9. Cation effects on phosphatidic acid monolayers at various pH conditions.

    Science.gov (United States)

    Zhang, Ting; Cathcart, Matthew G; Vidalis, Andrew S; Allen, Heather C

    2016-10-01

    The impact of pH and cations on phase behavior, stability, and surface morphology for dipalmitoylphosphatidic acid (DPPA) monolayers was investigated. At pHCations are found to expand and stabilize the monolayer in the following order of increasing magnitude at pH 5.6: Na + >K + ∼Mg 2+ >Ca 2+ . Additionally, cation complexation is tied to the pH and protonation state of DPPA, which are the primary factors controlling the monolayer surface behavior. The binding affinity of cations to the headgroup and thus deprotonation capability of the cation, ranked in the order of Ca 2+ >Mg 2+ >Na + >K + , is found to be well explained by the law of matching water affinities. Nucleation of surface 3D lipid structures is observed from Ca 2+ , Mg 2+ , and Na + , but not from K + , consistent with the lowest binding affinity of K + . Unraveling cation and pH effects on DPPA monolayers is useful in further understanding the surface properties of complex systems such as organic-coated marine aerosols where organic films are directly influenced by the pH and ionic composition of the underlying aqueous phase. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Photoconductivity, pH Sensitivity, Noise, and Channel Length Effects in Si Nanowire FET Sensors

    Science.gov (United States)

    Gasparyan, Ferdinand; Zadorozhnyi, Ihor; Khondkaryan, Hrant; Arakelyan, Armen; Vitusevich, Svetlana

    2018-03-01

    Silicon nanowire (NW) field-effect transistor (FET) sensors of various lengths were fabricated. Transport properties of Si NW FET sensors were investigated involving noise spectroscopy and current-voltage (I-V) characterization. The static I-V dependencies demonstrate the high quality of fabricated silicon FETs without leakage current. Transport and noise properties of NW FET structures were investigated under different light illumination conditions, as well as in sensor configuration in an aqueous solution with different pH values. Furthermore, we studied channel length effects on the photoconductivity, noise, and pH sensitivity. The magnitude of the channel current is approximately inversely proportional to the length of the current channel, and the pH sensitivity increases with the increase of channel length approaching the Nernst limit value of 59.5 mV/pH. We demonstrate that dominant 1/f-noise can be screened by the generation-recombination plateau at certain pH of the solution or external optical excitation. The characteristic frequency of the generation-recombination noise component decreases with increasing of illumination power. Moreover, it is shown that the measured value of the slope of 1/f-noise spectral density dependence on the current channel length is 2.7 which is close to the theoretically predicted value of 3.

  11. A review of pH calculation and corrosion product solubilities under PWR primary coolant chemistry conditions

    International Nuclear Information System (INIS)

    Thornton, E.W.; Polley, M.V.

    1986-12-01

    The calculation of high temperature pH in boric acid solutions is discussed and various relationships for the ionisation constant Ksub(w) or ion product Qsub(w) for water are reviewed. It is shown that the boric acid equilibria of Mesmer, Baes and Sweeton remain virtually unaltered when Marshall and Franck's relationship for Ksub(w) is substituted in a re-analysis of Mesmer, Baes and Sweeton's original experimental data. Magnetite solubility data and Westinghouse's studies of iron, nickel and cobalt solubility from mixed ferrites are collated and consideration is given to experimental difficulties which could have contributed to the variability in the data. Thermodynamic model fits have been computerised and used to compare different studies and to determine pH values at which the temperature dependence of solubility is predicted to be zero. Consideration is given to the differing dependences of solubility on dissolved hydrogen concentration in the three model fits. Two models for predicting iron and nickel solubility with respect to non-stoichiometric nickel ferrites are briefly discussed showing that only one of these is likely to be credible. (author)

  12. Adsorption of diclofenac onto organoclays: Effects of surfactant and environmental (pH and temperature) conditions

    OpenAIRE

    De Oliveira , Tiago; Guégan , Régis; Thiebault , Thomas; Le Milbeau , Claude; Muller , Fabrice; Teixeira , Vinicius; Giovanela , Marcelo; Boussafir , Mohammed

    2017-01-01

    Accepted Manuscript; International audience; Among pharmaceutical products (PPs) recalcitrant to water treatments, diclofenac shows a high toxicity and remains at high concentration in natural aquatic environments. The aim of this study concerns the understanding of the adsorption mechanism of this anionic PP onto two organoclays prepared with two long-alkyl chains cationic surfactants showing different chemical nature for various experimental pH and temperature conditions. The experimental d...

  13. Spore germination and gametophyte development of Cyathea atrovirens (Langsd. & Fisch. Domin (Cyatheaceae under different pH conditions

    Directory of Open Access Journals (Sweden)

    C. Rechenmacher

    Full Text Available Cyathea atrovirens (Langsd. & Fisch. Domin, an intensely exploited tree fern, is found inside forests in several succession stages, as well as in swamps, roadsides and unused fields in the Rio dos Sinos basin, in the state of Rio Grande do Sul, southern Brazil. This study evaluated the in vitro germination and gametophyte development of C.atrovirens under different pH conditions, as well as spore viability after different storage times at 7 ºC. The lowest germination rate of spores was obtained at pH 7.0. At pH 5.0 to 6.5, laminar gametophyte development started at 20 to 30 days of culture. Antheridia and archegonia were first observed at 35 and 128 days, respectively. Storage at 7 ºC did not affect germination rates. The capability of germination at different pH levels may explain the occurrence of the species in a wide range of habitats. The present study contributes to the understanding of the full life-cycle of C. atrovirens and to the analysis of the influence of abiotic components, providing information for the cultivation, management and conservation of the species.

  14. Continuous pH monitoring in a perfused bioreactor system using an optical pH sensor

    Science.gov (United States)

    Jeevarajan, Antony S.; Vani, Sundeep; Taylor, Thomas D.; Anderson, Melody M.

    2002-01-01

    Monitoring and regulating the pH of the solution in a bioprocess is one of the key steps in the success of bioreactor operation. An in-line optical pH sensor, based on the optical absorption properties of phenol red present in the medium, was developed and tested in this work for use in NASA space bioreactors based on a rotating wall-perfused vessel system supporting a baby hamster kidney (BHK-21) cell culture. The sensor was tested over three 30-day and one 124-day cell runs. The pH sensor initially was calibrated and then used during the entire cell culture interval. The pH reported by the sensor was compared to that measured by a fiber optically coupled Shimadzu spectrophotometer and a blood gas analyzer. The maximum standard error of prediction for all the four cell runs for development pH sensor against BGA was +/-0.06 pH unit and for the fiber optically coupled Shimadzu spectrophotometer against the blood gas analyzer was +/-0.05 pH unit. The pH sensor system performed well without need of recalibration for 124 days. Copyright 2002 Wiley Periodicals, Inc.

  15. Radiolysis of nitrite, bromate and permanganate ions and their binary mixtures in aqueous solutions at pH 10

    International Nuclear Information System (INIS)

    Dedgaonkar, V.G.; Kulkarni, S.A.; Mahajan, C.T.

    1981-01-01

    #betta#-radiolysis of pure systems viz. nitrite, bromate and permanganate and their binary mixtures (MNO 4- /NO 2- , MnO 4- /BrO 3- ) in aqueous solution at pH 10 is studied as a function of dose and concentration. In pure systems the G(NO 3- ), G(Br - ) and G(-MnO 4- ) increase with increasing concentration. The first two show an identical limiting value of approximately 0.5 while the last increases from 0.68 below 10 4 M and reaches 2.5 at 10 - 2 M concentration. Presence of 10 - 1 M BrO 3- or 10 - 2 M NO 2- reduces the G(-MnO 4- ) from 1.07 for the pure 10 - 3 M permanganate solution to 0.2 and 0.7 respectively. A mechanism based on the competitive kinetics is envisaged to explain the observed results. (author)

  16. Solubility measurement of iron-selenium compounds under reducing conditions. Research document

    International Nuclear Information System (INIS)

    Kitamura, Akira; Shibata, Masahiro

    2003-03-01

    Chemical behavior of selenium (Se), which was one of the important elements for performance assessment of geological disposal of high-level radioactive waste, was investigated under reducing and iron-containing conditions. A washing method for an iron diselenide (FeSe 2 (cr)) reagent with acidic and basic solutions (0.1 and 1 M HCl and 1 M NaOH) was carried out for the purification of FeSe 2 reagent, which was considered to be a solubility limiting solid for Se under the geological disposal conditions. Furthermore, solubility of FeSe 2 (cr) was measured in alkaline solution (pH: 11 - 13) under reducing conditions (E h vs SHE: -0.4 - 0 V), and thermodynamic data on equilibrium reactions between Se in solution and Se precipitate were obtained. The dependencies of solubility values on pH and redox potential (E h : vs. standard hydrogen electrode) were best interpreted that the solubility limiting solid was not FeSe 2 (cr) but Se(cr) and the aqueous species was SeO 3 2- in the present experimental conditions. The equilibrium constant between Se(cr) and SeO 3 2- at zero ionic strength was determined and compared with literature values. The chemical behavior of Se under geological disposal conditions was discussed. (author)

  17. Effect of interactions between carbon dioxide enrichment and NH4+/NO3- ratio on pH of culturing nutrient solution,growth and vigor of tomato root system

    Institute of Scientific and Technical Information of China (English)

    Juan LI; Jianmin ZHOU

    2008-01-01

    A growth chamber experiment was conducted to investigate the influence of NH4+/NO3- ratio and elevated CO2 concentration on the pH in nutrient solution,growth and root vigor system of tomato seedling roots,which attempts to understand whether the elevated CO2 concentration can alleviate the harmful effects of higher NH4+-N concentration in nutrient solutions on the tomato root system.Tomato (Lycopersicon esculenturn Mill.var.Hezuo 906) was grown in pots with nutrient solutions varying in NH4+/NO3- ratio (0:1,1:3,1:1,3:1and 1:0) and the growth chambers were supplied with with the growth process and CO2 concentration increased.At both CO2 levels,pH increased when 100% NO3--N was supplied and decreased in other treatments.The pH decrease in the nutrient solution was directly correlated to the NH4+-N proportion.The pH value was more reduced in 100% NH4+-N nutrient solution than increased in the 100% NO3--N nutrient solution.CO2 enrichment increased the dry weight of shoots and roots,root vigor system,total absorbing area and active absorbing area of tomato seedlings.All the measurement indexes above were increased in the elevated CO2 concentration treatment with the NO3- proportion increase in the nutrient solutions.Thus,under the elevated CO2 concentration,the dry weights of shoots and roots,root vigor system,total root absorbing area and active absorbing area were found to be inversely correlated to NH4+/NO3- ratio,leading to about 65.8%,78.0%,18.9%,12.9% and 18.9% increase,respectively,compared with that under the ambient CO2 concentration.Our results indicated that tomato seedling roots may benefit mostly from CO2 enrichment when 100% NO3--N nutrient solutions was supplied,but the CO2 concentration elevation did not alleviate the harmful effects when 100% NHa+-N was supplied.

  18. ''FIXBOX'' - a new technique for the reliable conditioning of plutonium waste solutions

    International Nuclear Information System (INIS)

    Bruchertseifer, H.; Sommer, E.; Steinemann, M.; Bart, G.

    1994-01-01

    ''FIXBOX'' - A new technique and facility for the conditioning of plutonium waste solutions has been developed and brought into operation in the Hot-laboratory at PSI, for the solidification of the waste from the research programmes. The facility is situated in glove-boxes for handling alpha activity and gamma-shielded for conditioning of fission product-containing waste. This report gives a brief description of the FIXBOX facility, the procedure and the first results of the cementation of plutonium waste solutions. As a result of this solidification, the actinide waste is homogeneous and strongly bound in the cement. The presence of gluconic acid and other complexing agents in the waste solution will not disturb this process. (author) figs., tabs., refs

  19. Stability of Adrenaline in Irrigating Solution for Intraocular Surgery.

    Science.gov (United States)

    Shibata, Yuuka; Kimura, Yasuhiro; Taogoshi, Takanori; Matsuo, Hiroaki; Kihira, Kenji

    2016-01-01

    Intraocular irrigating solution containing 1 µg/mL adrenaline is widely used during cataract surgery to maintain pupil dilation. Prepared intraocular irrigating solutions are recommended for use within 6 h. After the irrigating solution is admistered for dilution, the adrenaline may become oxidized, and this may result in a decrease in its biological activity. However, the stability of adrenaline in intraocular irrigating solution is not fully understood. The aim of this study was to evaluate the stability of adrenaline in clinically used irrigating solutions of varying pH. Six hours after mixing, the adrenaline percentages remaining were 90.6%±3.7 (pH 7.2), 91.1%±2.2 (pH 7.5), and 65.2%±2.8 (pH 8.0) of the initial concentration. One hour after mixing, the percentages remaining were 97.6%±2.0 (pH 7.2), 97.4%±2.7 (pH 7.5), and 95.6%±3.3 (pH 8.0). The degradation was especially remarkable and time dependent in the solution at pH 8.0. These results indicate that the concentration of adrenaline is decreased after preparation. Moreover, we investigated the influence of sodium bisulfite on adrenaline stability in irrigating solution. The percentage adrenaline remaining at 6 h after mixing in irrigating solution (pH 8.0) containing sodium bisulfite at 0.5 µg/mL (concentration in irrigating solution) or at 500 µg/mL (concentration in the undiluted adrenaline preparation) were 57.5 and 97.3%, respectively. Therefore, the low concentration of sodium bisulfite in the irrigating solution may be a cause of the adrenaline loss. In conclusion, intraocular irrigation solution with adrenaline should be prepared just prior to its use in surgery.

  20. Solution pH and oligoamine molecular weight dependence of the transition from monolayer to multilayer adsorption at the air-water interface from sodium dodecyl sulfate/oligoamine mixtures.

    Science.gov (United States)

    Halacheva, S S; Penfold, J; Thomas, R K; Webster, J R P

    2013-05-14

    Neutron reflectivity and surface tension have been used to investigate the solution pH and oligoamine molecular weight dependence of the adsorption of sodium dodecyl sulfate (SDS)/oligoamine mixtures at the air-water interface. For diethylenetriamine, triamine, or triethylenetetramine, tetramine mixed with SDS, there is monolayer adsorption at pH 7 and 10, and multilayer adsorption at pH 3. For the slightly higher molecular weight tetraethylenepentamine, pentamine, and pentaethylenehexamine, hexamine, the adsorption is in the form of a monolayer at pH 3 and multilayers at pH 7 and 10. Hence, there is a pH driven transition from monolayer to multilayer adsorption, which shifts from low pH to higher pH as the oligoamine molecular weight increases from tetramine to pentamine. This results from the relative balance between the electrostatic attraction between the SDS and amine nitrogen group which decreases as the charge density decreases with increasing pH, the ion-dipole interaction between the amine nitrogen and SDS sulfate group which is dominant at higher pH, and the hydrophobic interalkyl chain interaction between bound SDS molecules which changes with oligoamine molecular weight.

  1. Stabilizing sodium hypochlorite at high pH: effects on soft tissue and dentin.

    Science.gov (United States)

    Jungbluth, Holger; Marending, Monika; De-Deus, Gustavo; Sener, Beatrice; Zehnder, Matthias

    2011-05-01

    When sodium hypochlorite solutions react with tissue, their pH drops and tissue sorption decreases. We studied whether stabilizing a NaOCl solution at a high pH would increase its soft-tissue dissolution capacity and effects on the dentin matrix compared with a standard NaOCl solution of the same concentration and similar initial pH. NaOCl solutions were prepared by mixing (1:1) a 10% stock solution with water (standard) or 2 mol/L NaOH (stabilized). Physiological saline and 1 mol/L NaOH served as the controls. Chlorine content and alkaline capacity of NaOCl solutions were determined. Standardized porcine palatal soft-tissue specimens and human root dentin bars were exposed to test and control solutions. Weight loss percentage was assessed in the soft-tissue dissolution assay. Three-point bending tests were performed on the root dentin bars to determine the modulus of elasticity and flexural strength. Values between groups were compared using one-way analysis of variance with the Bonferroni correction for multiple testing (α pH level of 7.5, respectively. The stabilized NaOCl dissolved significantly more soft tissue than the standard solution, and the pH remained high. It also caused a higher loss in elastic modulus and flexure strength (P < .05) than the control solutions, whereas the standard solution did not. NaOH-stabilized NaOCl solutions have a higher alkaline capacity and are thus more proteolytic than standard counterparts. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Chemical Stability of Cd(II and Cu(II Ionic Imprinted Amino-Silica Hybrid Material in Solution Media

    Directory of Open Access Journals (Sweden)

    Buhani, Narsito, Nuryono, Eko Sri Kunarti

    2015-12-01

    Full Text Available Chemical stability of Cd(II and Cu(II ionic imprinted hybrid material of (i-Cd-HAS and i-Cu-HAS derived from silica modification with active compound (3-aminopropyl-trimethoxysilane (3-APTMS has been studied in solution media. Stability test was performed with HNO3 0.1 M (pH 1.35 to investigate material stability at low pH condition, CH3COONa 0.1 M (pH 5.22 for adsorption process optimum pH condition, and in the water (pH 9.34 for base condition. Material characteristics were carried out with infrared spectrophotometer (IR and atomic absorption spectrophotometer (AAS. At interaction time of 4 days in acid and neutral condition, i-Cd-HAS is more stable than i-Cu-HAS with % Si left in material 95.89 % (acid media, 43.82 % (close to neutral, and 9.39 % (base media.Keywords: chemical stability, amino-silica hybrid, ionic imprinting technique

  3. Chemical Stability of Cd(II and Cu(II Ionic Imprinted Amino-Silica Hybrid Material in Solution Media

    Directory of Open Access Journals (Sweden)

    Buhani Buhani

    2012-02-01

    Full Text Available Chemical stability of Cd(II and Cu(II ionic imprinted amino-silica (HAS material of (i-Cd-HAS and i-Cu-HAS derived from silica modification with active compound (3-aminopropyl-trimethoxysilane (3-APTMS has been studied in solution media.  Stability test was performed with HNO3 0.1 M (pH 1.35 to investigate material stability at low pH condition, acetat buffer at pH 5.22 for adsorption process optimum pH condition, and in the water (pH 9.34 for base condition.  Material characteristics were carried out with infrared spectrophotometer (IR and atomic absorption spectrophotometer (AAS.  At interaction time of 4 days in acid and neutral condition, i-Cd-HAS is more stable than i-Cu-HAS with % Si left in material 95.89 % (acid media, 43.82 % (close to neutral, and 9.39 % (base media.Keywords: chemical stability, amino-silica hybrid, ionic imprinting technique.

  4. Methodologically controlled variations in laboratory and field pH measurements in waterlogged soils

    DEFF Research Database (Denmark)

    Elberling, Bo; Matthiesen, Henning

    2007-01-01

    artefacts is critical. But the study includes agricultural and forest soils for comparison. At a waterlogged site, Laboratory results were compared with three different field methods: calomel pH probes inserted in the soil from pits, pH measurements of soil solution extracted from the soil, and pH profiles...... using a solid-state pH electrode pushed into the soil from the surface. Comparisons between in situ and laboratory methods revealed differences of more than 1 pH unit. The content of dissolved ions in soil solution and field observations of O2 and CO2 concentrations were used in the speciation model...... PHREEQE in order to predict gas exchange processes. Changes in pH in soil solution following equilibrium in the laboratory could be explained mainly by CO2 degassing. Only soil pH measured in situ using either calomel or solid-state probes inserted directly into the soil was not affected by gas exchange...

  5. Effect of pH on Pulp Potential and Sulphide Mineral Flotation

    OpenAIRE

    GÖKTEPE, Ferihan

    2014-01-01

    Control of pH is one of the most widely applied methods for the modulation of mineral flotation. In this study the effect of pH on potential in solution and sulphur minerals flotation is discussed with various electrodes. The electrodes were platinum, gold, chalcopyrite, pyrite and galena. In solution, potentials were linearly dependent on pH with a different slope for each electrode. Chalcopyrite, pyrite, sphalerite and galena minerals flotation tests were performed in a microflot...

  6. The isolation of beryllium and mercury from lithium chloride solution by means of gas extraction

    International Nuclear Information System (INIS)

    Sevast'yanov, A.I.; Chepovoj, V.I.

    1988-01-01

    The possibility and optimal conditions of beryllium and mercury extraction using acetylacetone (HAA) from lithium chloride solution by argon blowing through the solution are determined. Dependences of extraction degrees and distribution coefficients on different parameters of liquid phase: initial pH value, lithium chloride concentration and initial content of HAA, are presented. The degree of beryllium extraction reaches the maximum at liquid phase pH of 4.4-5.25 and concentration of lithium chloride of 8.5 mol/l. Distribution coefficient changes in inverse proportion to the extraction degree

  7. Biosorption of mercury from aqueous solutions using highly characterised peats

    Directory of Open Access Journals (Sweden)

    A.M. Rizzuti

    2015-02-01

    Full Text Available This research investigated the biosorption of mercury from aqueous solutions by six highly characterised peats. Samples of the peats were tested both in unaltered condition and after being treated with hydrochloric acid (HCl to free up any occupied exchange sites. Other variables tested were sample dose, contact time, mixing temperature, and the concentration and pH of the mercury solution. Desorption studies were also performed, and tests were done to determine whether the peats could be re-used for mercury biosorption. The results indicate that all six peat types biosorb mercury from aqueous solutions extremely well (92−100 % removal and that their mercury removal capacities are not significantly affected by manipulation of the various factors tested. The factor that had the greatest impact on the mercury removal capacities of the peats was the pH of the mercury solution. The optimal mercury solution pH for mercury removal was in the range 5−7 for four of the peats and in the range 2−3 for the other two. The desorption results indicate that it may be possible to recover up to 41 % of the removed mercury. All of the peat types tested can be repeatedly re-used for additional mercury biosorption cycles. Hence, their disposal should not become a hazardous waste problem.

  8. Effect of hydrogen on the fracture toughness of 17-4 PH stainless steel

    International Nuclear Information System (INIS)

    Capeletti, T.L.

    1976-01-01

    Fracture toughness (K/sub c/) of 17-4 PH stainless steel decreased significantly with increased hydrogen test pressure for a variety of heat treatment conditions: solution annealed, underaged, peak-aged, and overaged. Minimum toughness (13 MPa√m) was obtained with peak-aged samples tested in 69.5-MPa hydrogen; toughness was maximum (100 MPa√m) for samples tested in helium. Aging treatments increased the hardness from 28 R/sub c/ for solution-annealed material to 42 R/c/ for peak-aged material and correspondingly decreased the fracture toughness in high-pressure hydrogen (K/sub H/) from 31 to 13 MPa√m. However, increased hardness had no substantial effect on the K/sub c/ in helium. Fracture mechanism changed from predominantly ductile rupture in helium to cleavage in 69.5-MPa hydrogen, with mixed-mode fractures at lower hydrogen pressure (3.5-MPa). On the basis of these data, 17-4 PH stainless steel is not recommended for hydrogen service

  9. Adsorption of methylene blue from aqueous solution on the surface ...

    African Journals Online (AJOL)

    Adsorption of dye methylene blue from aqueous solution on the surface of sheep wool and cotton fibers was accomplished under the optimize conditions of temperature, concentration, pH, stay time duration and quantity of adsorbent. Spectrometric technique was used for the measurements of concentration of dye before ...

  10. Enhancement the conditioning of waste activated sludge through a sequence of freeze/thaw-electro-Fenton process

    Directory of Open Access Journals (Sweden)

    Shahheidar Narjes

    2018-03-01

    Full Text Available Sludge conditioning is an important stage in sludge management. In the present study, a sequence of freeze/thaw-electro-Fenton process was designed and specific resistance filtration (SRF was monitored during sludge conditioning as an important factor in sludge dewaterability. Furthermore, protein and polysaccharide concentrations were measured during the experiments. Results showed that the lowest SRF value contributed to −10°C in freezing process which showed a reducing trend by decreasing solution pH. In addition, results revealed that solution pH less than 3 caused a significant improvement in sludge dewatering; so the lowest SRF has been registered at pH = 2. By increasing current intensity from 0.5 to 1A, SRF values were reduced and then followed by an enhancement with increasing current intensity to 3.2 A. The lowest SRF value (6.1 × 104 m/kg was obtained at H2O2 = 30 mg/L which was the best conditions for sludge dewatering.

  11. Buffer-free therapeutic antibody preparations provide a viable alternative to conventionally buffered solutions: from protein buffer capacity prediction to bioprocess applications.

    Science.gov (United States)

    Bahrenburg, Sven; Karow, Anne R; Garidel, Patrick

    2015-04-01

    Protein therapeutics, including monoclonal antibodies (mAbs), have significant buffering capacity, particularly at concentrations>50 mg/mL. This report addresses pH-related issues critical to adoption of self-buffered monoclonal antibody formulations. We evaluated solution conditions with protein concentrations ranging from 50 to 250 mg/mL. Samples were both buffer-free and conventionally buffered with citrate. Samples were non-isotonic or adjusted for isotonicity with NaCl or trehalose. Studies included accelerated temperature stability tests, shaking stability studies, and pH changes in infusion media as protein concentrate is added. We present averaged buffering slopes of capacity that can be applied to any mAb and present a general method for calculating buffering capacity of buffer-free, highly concentrated antibody liquid formulations. In temperature stability tests, neither buffer-free nor conventionally buffered solution conditions showed significant pH changes. Conventionally buffered solutions showed significantly higher opalescence than buffer-free ones. In general, buffer-free solution conditions showed less aggregation than conventionally buffered solutions. Shaking stability tests showed no differences between buffer-free and conventionally buffered solutions. "In-use" preparation experiments showed that pH in infusion bag medium can rapidly approximate that of self-buffered protein concentrate as concentrate is added. In summary, the buffer capacity of proteins can be predicted and buffer-free therapeutic antibody preparations provide a viable alternative to conventionally buffered solutions. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Separation of beryllium and mercury from lithium chloride solution by gaseous extraction

    International Nuclear Information System (INIS)

    Sevast'yanov, A.I.; Chepovol, V.I.

    1989-01-01

    The possibility is shown of extracting beryllium and mercury by acetylacetone (HAA) from lithium chloride solution by passing argon through the solution and the optimum conditions have been determined. The dependence of the degree of extraction and the distribution coefficients on various parameters of the liquid phase are presented, viz. the initial pH value, the lithium chloride concentration, and the initial HAA content

  13. Effects of phytoextraction on heavy metal concentrations and pH of pore-water of biosolids determined using an in situ sampling technique

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, T.T. [Applied Ecology Research Group, School of Botany, University of Melbourne, Parkville, VIC 3010 (Australia)], E-mail: t.huynh11@pgrad.unimelb.edu.au; Laidlaw, W.S. [Applied Ecology Research Group, School of Botany, University of Melbourne, Parkville, VIC 3010 (Australia); Singh, B. [Faculty of Agriculture, Food and Natural Resources, University of Sydney, Sydney, NSW 2006 (Australia); Gregory, D. [Research and Technology Division, Melbourne Water, Melbourne, VIC 3001 (Australia); Baker, A.J.M. [Applied Ecology Research Group, School of Botany, University of Melbourne, Parkville, VIC 3010 (Australia)

    2008-12-15

    Heavy metal concentrations and pH of pore-water in contaminated substrates are important factors in controlling metal uptake by plants. We investigated the effects of phytoextraction on these properties in the solution phase of biosolids and diluted biosolids in a 12-month phytoextraction column experiment. Phytoextraction using Salix and Populus spp. temporarily decreased pore-water pH of the substrates over the experimental period followed by a return to initial pH conditions. Salix x reichardtii and Populus balsamifera effectively extracted Ni, Zn and Cd and actively mobilized these metals from the solid to the solution phase. S. x reichardtii had the stronger effect on mobilization of metals due to its larger root system. Phytoextraction did not affect Cu in the solution phase of the biosolids. Heavy metals were leached down to lower depths of the columns during the phytoextraction process. - Salix x reichardtii and Populus balsamifera extracted Ni, Zn and Cd and mobilized these metals in biosolids during phytoextraction.

  14. Effects of phytoextraction on heavy metal concentrations and pH of pore-water of biosolids determined using an in situ sampling technique

    International Nuclear Information System (INIS)

    Huynh, T.T.; Laidlaw, W.S.; Singh, B.; Gregory, D.; Baker, A.J.M.

    2008-01-01

    Heavy metal concentrations and pH of pore-water in contaminated substrates are important factors in controlling metal uptake by plants. We investigated the effects of phytoextraction on these properties in the solution phase of biosolids and diluted biosolids in a 12-month phytoextraction column experiment. Phytoextraction using Salix and Populus spp. temporarily decreased pore-water pH of the substrates over the experimental period followed by a return to initial pH conditions. Salix x reichardtii and Populus balsamifera effectively extracted Ni, Zn and Cd and actively mobilized these metals from the solid to the solution phase. S. x reichardtii had the stronger effect on mobilization of metals due to its larger root system. Phytoextraction did not affect Cu in the solution phase of the biosolids. Heavy metals were leached down to lower depths of the columns during the phytoextraction process. - Salix x reichardtii and Populus balsamifera extracted Ni, Zn and Cd and mobilized these metals in biosolids during phytoextraction

  15. Determination of the Optimum Conditions for Production of Chitosan Nanoparticles

    Directory of Open Access Journals (Sweden)

    A. Dustgani

    2007-12-01

    Full Text Available Bioedegradable nanoparticles are intensively investigated for their potential applications in drug delivery systems. Being a biocompatible and biodegradable polymer, chitosan holds great promise for use in this area. This investigation was concerned with determination and optimization of the effective parameters involved in the production of chitosan nanoparticles using ionic gelation method. Studied variables were concentration and pH of the chitosan solution, the ratio of chitosan to sodium tripolyphosphate therein and the molecular weight of chitosan. For this purpose, Taguchistatistical method was used for design of experiments in three levels. The size of chitosan nanoparticle was determined using laser light scattering. The experimental results showed that concentration of chitosan solution was the most important parameter and chitosan molecular weight the least effective parameter. The optimum conditions for preparation of nanoparticles were found to be 1 mg/mL chitosan solution with pH=5, chitosan to sodium tripolyphosphate ratio of 3 and chitosan molecular weight of 200,000 daltons. The average nanoparticle size at optimum conditions was found to be about 150 nm.

  16. Mobile geographic information system (GIS) solution for pavement condition surveys.

    Science.gov (United States)

    2012-06-28

    This report discusses the design and implementation of a software-based solution that will improve the data collection processes during the Pavement Condition Surveys (PCS) conducted by the State Materials Office (SMO) of the Florida Department of Tr...

  17. Standard Practice for Use of Mattsson's Solution of pH 7.2 to Evaluate the Stress- Corrosion Cracking Susceptibility of Copper-Zinc Alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers the preparation and use of Mattsson's solution of pH 7.2 as an accelerated stress-corrosion cracking test environment for brasses (copper-zinc base alloys). The variables (to the extent that these are known at present) that require control are described together with possible means for controlling and standardizing these variables. 1.2 This practice is recommended only for brasses (copper-zinc base alloys). The use of this test environment is not recommended for other copper alloys since the results may be erroneous, providing completely misleading rankings. This is particularly true of alloys containing aluminum or nickel as deliberate alloying additions. 1.3 This practice is intended primarily where the test objective is to determine the relative stress-corrosion cracking susceptibility of different brasses under the same or different stress conditions or to determine the absolute degree of stress corrosion cracking susceptibility, if any, of a particular brass or brass component ...

  18. Development of integrated radioactive waste packaging and conditioning solutions in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Sibley, Peter; Butter, Kevin; Zimmerman, Ian [EnergySolutions EU Ltd., Swindon, Wiltshire (United Kingdom); Viermann, Joerg [GNS Gesellschaft fur Nuklear-Service mbH, Essen (Germany); Messer, Matthias [GNS Gesellschaft fur Nuklear-Service mbH, Bristol (United Kingdom)

    2013-07-01

    In order to offer a more cost effective, safer and efficient Intermediate Level Waste (ILW) management service, EnergySolutions EU Ltd. and Gesellschaft fur Nuklear-Service mbH (GNS) have been engaged in the development of integrated radioactive waste retrieval, packaging and conditioning solutions in the UK. Recognising the challenges surrounding regulatory endorsement and on-site implementation in particular, this has resulted in an alternative approach to meeting customer, safety regulator and disposability requirements. By working closely with waste producers and the organisation(s) responsible for endorsing radioactive waste management operations in the UK, our proposed solutions are now being implemented. By combining GNS' off-the-shelf, proven Ductile Cast Iron Containers (DCICs) and water removal technologies, with EnergySolutions EU Ltd.'s experience and expertise in waste retrieval, safety case development and disposability submissions, a fully integrated service offering has been developed. This has involved significant effort to overcome technical challenges such as onsite equipment deployment, active commissioning, conditioning success criteria and disposability acceptance. Our experience in developing such integrated solutions has highlighted the importance of working in collaboration with all parties to achieve a successful and viable outcome. Ultimately, the goal is to ensure reliable, safe and effective delivery of waste management solutions. (authors)

  19. Dry matter and nitrogen accumulation are not affected by superoptimal concentration of ammonium in flowing solution culture with pH control

    Science.gov (United States)

    Rideout, J. W.; Raper, C. D. Jr; Raper CD, J. r. (Principal Investigator)

    1994-01-01

    While it is known that superoptimal concentrations of the nitrate (NO3-) ion in solution culture do not increase NO3- uptake or dry matter accumulation, the same is not known for the ammonium (NH4+) ion. An experiment was conducted utilizing flowing solution culture with pH control to investigate the influence of superoptimal NH4+ concentrations on dry matter, nitrogen (N), potassium (K), calcium (Ca), and magnesium (Mg) accumulation by nonnodulated soybean plants. Increasing the NH4+ concentration in solution from 1 to 10 mM did not affect dry matter or N accumulation. Accumulations of K, Ca, and Mg were slightly decreased with increased NH4+ concentration. The NH4+ uptake system, which is saturated at less than 1mM NH4+, is able to regulate uptake of NH4+ at concentrations as high as 10 mM.

  20. Effect of pH and uranium concentration on interaction of uranium(VI) and uranium(IV) with organic ligands in aqueous solutions

    International Nuclear Information System (INIS)

    Li, W.C.; Victor, D.M.; Chakrabarti, C.L.

    1980-01-01

    The effect of pH and uranium concentration on the interactions of uranium(VI) and uranium(IV) with organic ligands was studied by employing dialysis and ultrafiltration techniques. The interactions of U(VI) and U(IV) with organic ligands in nitrate or chloride aqueous solution have been found to be pH-dependent. The stability constants of uranium-organic complexes decrease in the order: fulvic acid>humic acid>tannic acid for U(VI) and humic acid>tannic acid>fulvic acid for U(IV). Scatchard plots for the uranium-organic acid systems indicate two types of binding sites with a difference in stability constants of about 10 2 . Ultrafiltration of uranium-humic acid complexes indicates that U(VI) and U(IV) ions are concentrated in larger molecular size fractions (>5.1 nm) at pH less than or equal to 3 and in smaller molecular size fractions (in the range 5.1 to 3.1 nm and 2.4 to 1.9 nm) at pH greater than or equal to 5. 7 figures, 4 tables

  1. Degradation of malachite green in aqueous solution by Fenton process.

    Science.gov (United States)

    Hameed, B H; Lee, T W

    2009-05-30

    In this study, advanced oxidation process utilizing Fenton's reagent was investigated for degradation of malachite green (MG). The effects of different reaction parameters such as the initial MG concentration, initial pH, the initial hydrogen peroxide concentration, the initial ferrous concentration and the reaction temperature on the oxidative degradation of MG have been investigated. The optimal reacting conditions were experimentally found to be pH 3.40, initial hydrogen peroxide concentration=0.50mM and initial ferrous concentration=0.10mM for initial MG concentration of 20mg/L at 30 degrees C. Under optimal conditions, 99.25% degradation efficiency of dye in aqueous solution was achieved after 60 min of reaction.

  2. Clostridium tyrobutyricum strains show wide variation in growth at different NaCl, pH, and temperature conditions.

    Science.gov (United States)

    Ruusunen, Marjo; Surakka, Anu; Korkeala, Hannu; Lindström, Miia

    2012-10-01

    Outgrowth from Clostridium tyrobutyricum spores in milk can lead to butyric acid fermentation in cheeses, causing spoilage and economical loss to the dairy industry. The aim of this study was to investigate the growth of 10 C. tyrobutyricum strains at different NaCl, pH, and temperature conditions. Up to 7.5-fold differences among the maximum growth rates of different strains in the presence of 2.0% NaCl were observed. Five of 10 strains were able to grow in the presence of 3.0% NaCl, while a NaCl concentration of 3.5% was completely inhibitory to all strains. Seven of 10 strains were able to grow at pH 5.0, and up to 4- and 12.5-fold differences were observed among the maximum growth rates of different strains at pH 5.5 and 7.5, respectively. The maximum growth temperatures varied from 40.2 to 43.3°C. The temperature of 10°C inhibited the growth of all strains, while 8 of 10 strains grew at 12 and 15°C. Despite showing no growth, all strains were able to survive at 10°C. In conclusion, wide variation was observed among different C. tyrobutyricum strains in their ability to grow at different stressful conditions. Understanding the physiological diversity among the strains is important when designing food control measures and predictive models for the growth of spoilage organisms in cheese.

  3. CMOS COLOUR SENSOR BASED pH MEASUREMENT FOR WATER QUALITY ANALYSIS

    OpenAIRE

    Sanjay Kumar; Arvind Singh

    2016-01-01

    A Real-Time pH measurement system using a novel design Programmable CMOS optical Colour light to frequency converter TCS230 is presented. The system uses Bogen’s universal indicator solution combined with a white light source and the Programmable CMOS colour sensor TCS230 to measure pH as a function of colour change in a sample. Bogen’s universal indicator solution causes a colour change in a sample according to the pH of the sample. The output frequency from the colour-sensitive CM...

  4. Exact solution for four-order acousto-optic Bragg diffraction with arbitrary initial conditions.

    Science.gov (United States)

    Pieper, Ron; Koslover, Deborah; Poon, Ting-Chung

    2009-03-01

    An exact solution to the four-order acousto-optic (AO) Bragg diffraction problem with arbitrary initial conditions compatible with exact Bragg angle incident light is developed. The solution, obtained by solving a 4th-order differential equation, is formalized into a transition matrix operator predicting diffracted light orders at the exit of the AO cell in terms of the same diffracted light orders at the entrance. It is shown that the transition matrix is unitary and that this unitary matrix condition is sufficient to guarantee energy conservation. A comparison of analytical solutions with numerical predictions validates the formalism. Although not directly related to the approach used to obtain the solution, it was discovered that all four generated eigenvalues from the four-order AO differential matrix operator are expressed simply in terms of Euclid's Divine Proportion.

  5. Remoção de metais pesados de efluentes aquosos pela zeólita natural escolecita - influência da temperatura e do pH na adsorção em sistemas monoelementares Heavy metals removal from wastewater by the natural zeolite scolecite - temperature and pH influence in single-metal solutions

    Directory of Open Access Journals (Sweden)

    Ricardo Sarti Jimenez

    2004-10-01

    Full Text Available Cation exchange capabilities of a Brazilian natural zeolite, identified as scolecite, were evaluated for application in wastewater control. We investigated the process of sorption of chromium(III, nickel(II, cadmium(II and manganese(II in synthetic aqueous effluents, including adsorption isotherms of single-metal solutions. The natural zeolite showed the ability to take up the tested heavy metals in the order Cr(III > Cd(II > Ni(II > Mn(II, and this could be related to the valence and the hydration radius of the metal cations. The influence of temperature (25, 40 and 60 ºC and initial pH value (from 4 to 6 was also evaluated. It was found that the adsorption increased substantially when the temperature was raised to 60 ºC and that maximum adsorption capacity was observed at pH 6. These results demonstrate that scolecite can be used for removal of heavy metals from aqueous effluents, under optimized conditions.

  6. A comparative study of the metastable equilibrium solubility behavior of high-crystallinity and low-crystallinity carbonated apatites using pH and solution strontium as independent variables.

    Science.gov (United States)

    Heslop, D D; Bi, Y; Baig, A A; Otsuka, M; Higuchi, W I

    2005-09-01

    Using solution strontium and pH as independent variables, the metastable equilibrium solubility (MES) behavior of two carbonated apatite (CAP) samples has been examined, a high-crystallinity CAP (properties expected to be similar to dental enamel) and a low-crystallinity CAP (properties expected to be similar to bone mineral). CAP samples were prepared by precipitation/digestion: (CAP A: high-crystallinity, 1.3 wt% CO3, synthesized at 85 degrees C; CAP B: low-crystallinity, 6.4 wt% CO3, synthesized at 50 degrees C). Baseline MES distributions were determined in a series of 0.1 M acetate buffers containing only calcium and phosphate (no strontium) over a broad range of solution conditions. To assess the influence of strontium, MES profiles were determined in a similar fashion with 20, 40, 60, and 80% of the solution calcium being replaced on an equal molar basis by solution strontium. To determine the correct function governing CAP dissolution, ion activity products (IAPs) were calculated from the compositions of buffer solutions based on the hydroxyapatite template (Ca(10-n)Sr(n)(PO4)6(OH)2 (n = 0-10)) and the calcium/hydroxide deficient hydroxyapatite template (Ca(9-n)Sr(n)(HPO4)(PO4)5OH (n = 0-9)). (a) for CAP A, at high solution strontium/calcium ratios, the MES profiles were essentially superimposable when the solution IAPs were calculated using the stoichiometry of Ca6Sr4(PO4)6(OH)2 and for CAP B by a stoichiometry of Ca7Sr2(HPO4)(PO4)5OH; (b) for CAP A, at low strontium/calcium ratios, the stoichiometry yielding MES data superpositioning was found to be that of hydroxyapatite and for CAP B, that of calcium/hydroxide deficient hydroxyapatite. When other stoichiometries were assumed, good superpositioning of the data was not possible.

  7. Two decades of chemical imaging of solutes in sediments and soils

    DEFF Research Database (Denmark)

    Santner, Jakob; Larsen, Morten; Kreuzeder, Andreas

    2015-01-01

    understanding of biogeochemical processes regulating the distribution of key elements and solutes including O2, CO2, pH, redox conditions as well as nutrient and contaminant ion species in structurally complex soils and sediments. Recently these methods have been applied in parallel or integrated as so...

  8. Reduction of exchangeable calcium and magnesium in soil with increasing pH

    Directory of Open Access Journals (Sweden)

    Miyazawa Mário

    2001-01-01

    Full Text Available A laboratory study was conducted with soil samples and synthetic solutions to investigate possible mechanisms related with reduction in KCl exchangeable Ca and Mg with increasing pH. Increasing soil pH over 5.3 with CaCO3 added to the soil and with NaOH solution added to soil/KCl suspension increased adsorptions of Ca and Mg. The reduction of Mg was greater than Ca and was related to the concentration of soil exchangeable Al. The decreases of soluble Ca and Mg following addition of Al in synthetic solution were at pH > 7.5. The isomorphic coprecipitation reaction with Al compounds may be the most possible mechanism responsible for the decrease of exchangeable Ca and Mg with increasing pH. Possible chemical reactions are presented.

  9. Influence of sulfate ion concentration and pH on the corrosion of Mg-Al-Zn-Mn (GA9 magnesium alloy

    Directory of Open Access Journals (Sweden)

    Sudarshana Shetty

    2015-09-01

    Full Text Available The corrosion behavior of Mg-Al-Zn-Mn (GA9 alloy in sodium sulfate solutions was studied over a range of concentrations and solution temperatures at different pH conditions by electrochemical techniques like Tafel extrapolation and electrochemical impedance spectroscopy (EIS. The studies were carried out in solutions with sodium sulfate concentrations 0.1M, 0.5M, 1M, 1.5M and 2M; and at five different temperatures of 30, 35, 40, 45 and 50 °C in a pH range of 3–12. As per the experimental data, the corrosion rate of the alloy increased with the increase in temperature, and also with the increase in concentration of sodium sulfate in the medium. It was observed that the rate of corrosion decreased with the increase in pH. The activation parameters like activation energy, enthalpy of activation and entropy of activation for the corrosion process were calculated. The surface morphology of the alloy was examined before and after corrosion using scanning electron microscopy (SEM.

  10. A simple protocol for the routine calibration of pH meters

    Directory of Open Access Journals (Sweden)

    A. FEDERMAN NETO

    2009-01-01

    Full Text Available

    A simplified laboratory protocol for the calibration of pH meters is described and tested. It is based on the use of two analytical primary buffer solutions, potassium hydrogen phthalate and Borax (sodium tetraborate decahydrate of precisely known concentrations and pH. The solutions may be stored at room temperature for long periods, without decomposition and used directly. The calibration of the meter can be checked with standard solutions of sodium dihydrogen phosphate, sodium carbonate, sodium benzoate, sodium salicylate or potassium oxalate. Methods for the purification of Borax and potassium chloride are also given, and a new method for the neutralization of 0.9% saline is suggested. Keywords: pH meters (calibration; saline (0.9%; pH standards; potassium biphthalate; Borax.

  11. Laser Raman spectra of mono-, oligo- and polysaccharides in solution

    Science.gov (United States)

    Barrett, T. W.

    We examined the Raman spectra of thirteen sugars—seven monosaccharides, two disaccharides, one trisaccharide and three polysaccharides—in the wavelength range 200—1700 cm -1 and (i) varied the phosphate buffered solution from pH 6.0 to 8.5 at constant ionic strength of 0.1 and (ii) varied HCl solutions from pH 0.8 to 5.0. As is to be expected with molecules containing COH groupings, all the molecular spectra are distinct. Of the thirteen sugars examined, only D-fructose 1,6-diphosphate (FDP) demonstrated spectral changes for the pH range 6.0—8.5 in phosphate buffer; but all exhibited band intensity enhancement in HCl at the lower pHs, but not band wavenumber changes. The results indicate that: (i) changes in the pH of the major intracellular buffer, phosphate, toward acidity, are able to hydrolyze the 1-phosphate group of FDP and the relative concentration of fructose 1-phosphate to fructose 6-phosphate is indicated by the intensity ratio of the 982 and 1080 cm -1 bands; (ii) it appears that all phosphate groups of FDP are hydrolyzed at pH 0.8 in HCl; and (iii) although conditions of extreme acidity are able to hydrolyze other sugars examined, there is no major degradation.

  12. BSA-coated nanoparticles for improved SERS-based intracellular pH sensing.

    Science.gov (United States)

    Zheng, Xiao-Shan; Hu, Pei; Cui, Yan; Zong, Cheng; Feng, Jia-Min; Wang, Xin; Ren, Bin

    2014-12-16

    Local microenvironment pH sensing is one of the key parameters for the understanding of many biological processes. As a noninvasive and high sensitive technique, surface-enhanced Raman spectroscopy (SERS) has attracted considerable interest in the detection of the local pH of live cells. We herein develop a facile way to prepare Au-(4-MPy)-BSA (AMB) pH nanosensor. The 4-MPy (4-mercaptopyridine) was used as the pH sensing molecule. The modification of the nanoparticles with BSA not only provides a high sensitive response to pH changes ranging from pH 4.0 to 9.0 but also exhibits a high sensitivity and good biocompatibility, stability, and reliability in various solutions (including the solutions of high ionic strength or with complex composition such as the cell culture medium), both in the aggregation state or after long-term storage. The AMB pH nanosensor shows great advantages for reliable intracellular pH analysis and has been successfully used to monitor the pH distribution of live cells and can address the grand challenges in SERS-based pH sensing for practical biological applications.

  13. The pH dependent Raman spectroscopic study of caffeine

    Science.gov (United States)

    Kang, Jian; Gu, Huaimin; Zhong, Liang; Hu, Yongjun; Liu, Fang

    2011-02-01

    First of all the surface enhanced Raman spectroscopy (SERS) and normal Raman spectra of caffeine aqueous solution were obtained at different pH values. In order to obtain the detailed vibrational assignments of the Raman spectroscopy, the geometry of caffeine molecule was optimized by density functional theory (DFT) calculation. By comparing the SERS of caffeine with its normal spectra at different pH values; it is concluded that pH value can dramatically affect the SERS of caffeine, but barely affect the normal Raman spectrum of caffeine aqueous solution. It can essentially affect the reorientation of caffeine molecule to the Ag colloid surface, but cannot impact the vibration of functional groups and chemical bonds in caffeine molecule.

  14. Chapter A6. Section 6.4. pH

    Science.gov (United States)

    Wilde, Franceska D.; Busenberg, Eurybiades; Radtke, Dean B.

    2006-01-01

    Measurement of pH is critical to the understanding of the viability and vulnerability of environmental waters and is considered a master variable in determining the aqueous geochemistry of an aqueous system. pH is a measure that represents the hydrogen-ion concentration (activity) of a solution. This section of the National Field Manual (NFM) describes U.S. Geological Survey (USGS) guidance and protocols for measurement of pH in ground and surface waters.

  15. A novel fluorescence probe based on triphenylamine Schiff base for bioimaging and responding to pH and Fe{sup 3+}

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lei; Yang, Xiaodong; Chen, Xiuli [School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China); Zhou, Yuping [Guangdong Provincial key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, Guangzhou 510515 (China); Lu, Xiaodan; Yan, Chenggong; Xu, Yikai [Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou 510515 (China); Liu, Ruiyuan, E-mail: ruiyliu@smu.edu.cn [Guangdong Provincial key Laboratory of New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, Guangzhou 510515 (China); Qu, Jinqing, E-mail: cejqqu@scut.edu.cn [School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China)

    2017-03-01

    A novel fluorescence probe 1 based on triphenylamine was synthesized and characterized by NMR, IR, high resolution mass spectrometry and elemental analysis. Its fluorescence was quenched when pH below 2. There was a linear relationship between the fluorescence intensity and pH value ranged from 2 to 7. And its fluorescence emission was reversibility in acidic and alkaline solution. Furthermore, it exhibited remarkable selectivity and high sensitivity to Fe{sup 3+} and was able to detect Fe{sup 3+} in aqueous solution with low detection limit of 0.511 μM. Job plot showed that the binding stoichiometry of 1 with Fe{sup 3+} was 1:1. Further observations of {sup 1}H NMR titration suggested that coordination interaction between Fe{sup 3+} and nitrogen atom on C =N bond promoted the intramolecular charge transfer (ICT) or energy transfer process causing fluorescence quenching. Additionally, 1 was also able to be applied for detecting Fe{sup 3+} in living cell and bioimaging. - Graphical abstract: Triphenylamine based fluorescence probe can detect pH and Fe{sup 3+} simultaneously in aqueous solution and be applied for detecting Fe{sup 3+} in living cell and bioimaging. - Highlights: • The fluorescence probe is sensitive to pH in strong acid conditions. • The fluorescence chemosensor can detect pH and Fe{sup 3+} simultaneously. • The recognition is able to carry out in aqueous solution. • The probe can also be applied for detecting Fe{sup 3+} in living cell and bioimaging. • The sensor is synthesized easily with one step.

  16. The pH sensitive properties of carboxymethyl chitosan nanoparticles cross-linked with calcium ions.

    Science.gov (United States)

    Kalliola, Simo; Repo, Eveliina; Srivastava, Varsha; Heiskanen, Juha P; Sirviö, Juho Antti; Liimatainen, Henrikki; Sillanpää, Mika

    2017-05-01

    In environmental applications the applied materials are required to be non-toxic and biodegradable. Carboxymethyl chitosan nanoparticles cross-linked with Ca 2+ ions (CMC-Ca) fulfill these requirements, and they are also renewable. These nanoparticles were applied to oil-spill treatment in our previous study and here we focused on enhancing their properties. It was found that while the divalent Ca 2+ ions are crucial for the formation of the CMC-Ca, the attractive interaction between NH 3 + and COO - groups contributed significantly to the formation and stability of the CMC-Ca. The stability decreased as a function of pH due to the deprotonation of the amino groups. Therefore, the nanoparticles were found to be fundamentally pH sensitive in solution, if the pH deviated from the pH (7-9) that was used in the synthesis of the nanoparticles. The pH sensitive CMC-Ca synthesized in pH 7 and 8 were most stable in the studied conditions and could find applications in oil-spill treatment or controlled-release of substances. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. CdSe/ZnS quantum dots conjugated with a fluorescein derivative: a FRET-based pH sensor for physiological alkaline conditions.

    Science.gov (United States)

    Kurabayashi, Tomokazu; Funaki, Nayuta; Fukuda, Takeshi; Akiyama, Shinnosuke; Suzuki, Miho

    2014-01-01

    Dual pH-dependent fluorescence peaks from a semiconductor quantum dot (QD) and a pH-dependent fluorescent dye can be measured by irradiating with a single wavelength light, and the pH can be estimated from the ratio of the fluorescent intensity of the two peaks. In this work, ratiometric pH sensing was achieved in an aqueous environment by a fluorescent CdSe/ZnS QD appended with a pH-sensitive organic dye, based on fluorescence resonance energy transfer (FRET). By functionalizing the CdSe/ZnS QD with 5-(and 6)-carboxynaphthofluorescein succinimidyl ester as a pH-dependent fluorescent dye, we succeeded in fabricating sensitive nanocomplexes with a linear response to a broad range of physiological pH levels (7.5-9.5) when excited at 450 nm. We found that a purification process is important for increasing the high-fluorescence intensity ratio of a ratiometric fluorescence pH-sensor, and the fluorescence intensity ratio was improved up to 1.0 at pH 8.0 after the purification process to remove unreacted CdSe/ZnS QDs even though the fluorescence of the dye could not be observed without the purification process. The fluorescence intensity ratio corresponds to the fluorescence intensity of the dye, and this fluorescent dye exhibited pH-dependent fluorescence intensity changes. These facts indicate that the fluorescence intensity ratio linearly increased with increasing pH value of the buffer solution containing the QD and the dye. The FRET efficiencies changed from 0.3 (pH 7.5) to 6.2 (pH 9.5).

  18. In Vitro binding capacity of zeolite A to calcium, phosphorus and magnesium in rumen fluid as influenced by changes in pH

    DEFF Research Database (Denmark)

    Thilsing, Trine; Jørgensen, Rolf Jess; Poulsen, H.D.

    2006-01-01

    with and without zeolite, as well as varying the content of Ca and/or P. The pH was lowered by addition of HCl so as to mimic abomasal conditions, followed by subsequent HCO3- addition to mimic small intestinal pH. Rumen fluid samples were taken at strategic time points in the experiment. All samples were......An in vitro experiment was designed to mimic the transport of ingested zeolite A in the forestomachs and proximal part of the small intestine so as to evaluate the binding capacity of zeolite A to Ca, P and Mg as influenced by changes in pH. This was done by incubation of rumen fluid solutions...... centrifuged and the supernatant analysed for Ca, P and Mg as indicators of the amount of unbound mineral. The addition of zeolite to rumen fluid solutions reduced the amount of supernatant Ca and Mg at rumen pH, whereas the level of P was not reduced. After adding HCl, a large proportion of the zeolite...

  19. Application of electrochemically generated ozone to the discoloration and degradation of solutions containing the dye Reactive Orange 122

    International Nuclear Information System (INIS)

    Santana, Mario H.P.; Da Silva, Leonardo M.; Freitas, Admildo C.; Boodts, Julien F.C.; Fernandes, Karla C.; De Faria, Luiz A.

    2009-01-01

    Aqueous solutions containing the commercial azo dye Reactive Orange 122 (RO122) were ozonated in acid and alkaline conditions. Ozone was electrochemically generated using a laboratory-made electrochemical reactor and applied using semi-batch conditions and a column bubble reactor. A constant ozone application rate of 0.25 g h -1 was used throughout. Color removal and degradation efficiency were evaluated as function of ozonation time, pH and initial dye concentration by means of discoloration kinetics and COD-TOC removal. Experimental findings revealed that pH affects both discoloration kinetics and COD-TOC removal. A single pseudo-first-order kinetic rate constant, k obs , for discoloration was found for ozonation carried out in alkaline solutions, contrary to acidic solutions where k obs depends on ozonation time. COD-TOC removal supports degradation of RO122 is more pronounced for alkaline conditions. Evaluation of the oxidation feasibility by means of the COD/TOC ratio indicates that the ozonation process in both acid and alkaline conditions leads to a reduction in recalcitrance of the soluble organic matter

  20. Calibration of antimony-based electrode for ph monitoring into underground components of nuclear repositories

    International Nuclear Information System (INIS)

    Betelu, S.; Ignatiadis, I.

    2012-01-01

    reserve of material. Monocrystalline Sb was used without any (pre)treatment over the experiments (16 month).The high binding energy led to a low corrosion rate and therefore the surface was only slowly changed and occluding oxide was almost completely avoided. The uniform binding energy promoted a uniform corrosion on the surface. Performances, reliability and robustness were examined by potentiometric measurements at 25 C. Investigation has been limited in pH, ranging from 5.5 to 13.5, close to those encountered in the environment of the nuclear repositories. The feasibility of measuring pH with Sb-based electrodes was first tested in NH 4 Cl/NH 3 buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. The influence of the presence P(V), Cl(-I), N(V), on the analytical signal was studied from solutions plug NaH 2 PO 4 /NaHPO 4 (Ionic Strength (IS): 0.1), NaCl (0.1 mol.L -1 ), NaNO 3 (1 to 6 10 -3 mol.L -1 ). Experiments were also conducted in NaHCO 3 /Na 2 CO 3 buffer samples, similar to conditions prevailing in the COx formation. Ionic strength was investigated from 0.05 to 0.2. When necessary, NaOH was used to extend the curve to the region of high pH value. In addition to measurements done under atmospheric oxygen saturation while the influence of the O 2 /H 2 O redox couple was being studied, several measurements were also done in a glove box (GB or BAG) in an oxygen-free atmosphere. These were done to the anticipated decrease in the redox potential in the COx pore water caused by the decrease in the O 2 concentration. The same measurements were also done using a 10-mm disk platinum electrode with a surface of 78.54 mm 2 . The general convergence of the stabilization potential revealed the occurrence of an equilibrium state under the experimental conditions. Sb-based electrodes rapidly responded to changes in pH with regard to the relative standard deviation based on repeatability. The equilibrium state remains

  1. Positive solutions of nonlinear fractional boundary value problems with Dirichlet boundary conditions

    Directory of Open Access Journals (Sweden)

    Qingkai Kong

    2012-02-01

    Full Text Available In this paper, we study the existence and multiplicity of positive solutions of a class of nonlinear fractional boundary value problems with  Dirichlet boundary conditions. By applying the fixed point theory on cones we establish a series of criteria for the existence of one, two, any arbitrary finite number, and an infinite number of positive solutions. A criterion for the nonexistence of positive solutions is also derived. Several examples are given for demonstration.

  2. Struvite recovery from swine waste biogas digester effluent through a stainless steel device under constant pH conditions.

    Science.gov (United States)

    Perera, P W Anton; Wu, Wei-Xiang; Chen, Ying-Xu; Han, Zhi-Ying

    2009-06-01

    To investigate the struvite precipitation under constant and non-constant pH conditions and to test a stainless steel device under different operating regimes to maximize the recovery of struvite. The molar ratio of NH4+: Mg2+: PO4(3-) was adjusted to 1: 1.2: 1.2 and pH was elevated to 9.0. The absorbance measurement was used to trace the process of struvite crystallization. Wastewater and precipitate analysis was done by standard analytical methods. The pH constant experiment reported a significantly higher struvite precipitation (24.6 +/- 0.86 g) than the non-constant pH experiment (19.8 +/- 1.86 g). The SAR ranged from 5.6 to 8.2 g m(-2) h(-1) to 3.6-4.8 g m(-2) h(-1) in pH constant and non-constant experiments, respectively. The highest struvite deposit on the device was found in regime 3 followed by in regimes 2 and 4. The highest PO4(3-) (97.2%) and NH4+ (71%) removal was reported in the R1 regime. None of the influent Cu2+ or Zn2+ was precipitated on the device. A higher struvite yield is evident in pH constant experiments. Moreover, the stainless steel device facilitates the isolation of heavy metal free pure (around 96%) struvite from swine waste biogas digester effluent contaminated with cu2+ and Zn2+ and the highest yield is attainable with the device operating at 50 rpm with agitation by a magnetic stirrer.

  3. Optical and photophysical properties of the chlorin-type photosensitizer photolon in aqueous solutions of different acidities

    Science.gov (United States)

    Bagrov, I. V.; Belousova, I. M.; Dadeko, A. V.; Krisko, T. K.; Kriukova, E. V.; Martynenko, I. V.; Savchenko, M. R.

    2017-09-01

    Photolon is a modern compound for fluorescence diagnostics and photodynamic therapy, which was relatively recently introduced into clinical practice. In the present work, we study its electronic-absorption spectra, fluorescence spectra (excited at different visible wavelengths), and fluorescence quantum yields. The characteristics are studied in aqueous solutions with pH 6.0-7.5 and compared under identical conditions with the corresponding characteristics of other chlorin- or porphyrin-type compounds (Photoditazin, Radachlorin, Dimegin) for photodynamic diagnostics and therapy. It is shown that the studied properties of Photolon are very close to those of Photoditazin and Radachlorin. At the same time, chlorin products are found to be more effective than Dimegin at pH 7.5, which is close to the pH of blood, while Dimegin is the most effective in solutions with lower pH, for example, in distilled water.

  4. Cr(VI) removal from aqueous solution by dried activated sludge biomass

    International Nuclear Information System (INIS)

    Wu Jun; Zhang Hua; He Pinjing; Yao Qian; Shao Liming

    2010-01-01

    Batch experiments were conducted to remove Cr(VI) from aqueous solution using activated sludge biomass. The effects of acid pretreatment of the biomass, initial pH, biomass and Cr(VI) concentrations on Cr(VI) removal efficiency were investigated. Proton consumption during the removal process and the reducing capacity of sludge biomass were studied. The results show that acid pretreatment could significantly improve Cr(VI) removal efficiency and increase Cr(VI) reducing capacity by 20.4%. Cr(VI) removal was remarkably pH-dependent; lower pH (pH = 1, 2) facilitated Cr(VI) reduction while higher pH (pH = 3, 4) favored sorption of the converted Cr(III). Lower Cr(VI) concentration as well as higher biomass concentration could accelerate Cr(VI) removal. Cr(VI) reduction was not the only reason for proton consumption in the removal process. Pseudo-second-order adsorption kinetic model could successfully simulate Cr(VI) removal except under higher pH conditions (pH = 3, 4).

  5. Effect of pH, ionic strength and fulvic acid on the sorption and desorption of cobalt to bentonite

    International Nuclear Information System (INIS)

    Yu, Sh.M.; Ren, A.P.; Chen, Ch.L.; Chen, Y.X.; Wang, X.

    2006-01-01

    Humic substances and bentonite have attracted great interest in radioactive waste management. Here the sorption of cobalt on bentonite in the presence and absence of fulvic acid (FA) under ambient conditions was studied. The effects of pH, ionic strength, FA and solution concentrations on cobalt sorption to bentonite were also investigated using batch techniques. The results indicate that the sorption of cobalt is strongly dependent on pH and is independent of ionic strength under our experimental conditions. Surface complexation is considered the main mechanism of cobalt sorption to bentonite. In the presence of FA, little effect of FA on cobalt sorption was found at pH 8. The addition sequences of FA/Co 2+ to the bentonite suspension on the sorption of cobalt to FA-coated bentonite were also studied. The results indicated that the sorption is not influenced by the addition sequences. Some possible mechanisms are discussed

  6. Analytical solutions for coupling fractional partial differential equations with Dirichlet boundary conditions

    Science.gov (United States)

    Ding, Xiao-Li; Nieto, Juan J.

    2017-11-01

    In this paper, we consider the analytical solutions of coupling fractional partial differential equations (FPDEs) with Dirichlet boundary conditions on a finite domain. Firstly, the method of successive approximations is used to obtain the analytical solutions of coupling multi-term time fractional ordinary differential equations. Then, the technique of spectral representation of the fractional Laplacian operator is used to convert the coupling FPDEs to the coupling multi-term time fractional ordinary differential equations. By applying the obtained analytical solutions to the resulting multi-term time fractional ordinary differential equations, the desired analytical solutions of the coupling FPDEs are given. Our results are applied to derive the analytical solutions of some special cases to demonstrate their applicability.

  7. No-core fiber-based highly sensitive optical fiber pH sensor.

    Science.gov (United States)

    Bhardwaj, Vanita; Pathak, Akhilesh Kumar; Singh, Vinod Kumar

    2017-05-01

    The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different types of indicators (bromophenol blue, cresol red, and chlorophenol red) were used to achieve a wide pH range from 2 to 13. High sensitivities of the fabricated device were found to be 1.02 and ? 0.93 ?? nm / pH for acidic and alkaline solutions, respectively. From the characterization results, it was noted that there is an impact of ionic strength and an effect of the temperature of liquid on the response characteristic, which is an advantage of the existing device over the other pH sensors. The fabricated sensor exhibited good reflection spectrum, indicating a blueshift in resonance wavelength for alkaline solutions and a redshift for acidic solutions.

  8. Intracellular pH and 42.00 C heat response of CHO cells cultured at pH 6.6

    International Nuclear Information System (INIS)

    Cook, J.A.; Fox, M.H.

    1987-01-01

    The authors previously reported that cells under chronic low pH (6.6) conditions have altered thermotolerance. They further characterized both the doubling time (t/sub d/) and the internal pH (pH/sub 1/) of CHO cells continuously cultured at pH 6.6 for times greater than one year. The following differences were noted: 1) A t/sub d/ of 16 hr compared to a t/sub d/ of 12 hr for cells at normal pH (7.3) and a t/sub d/ of 25 hr for the acute low pH cells (pH = 6.6; incubation time = 4 hr). 2) A pH/sub i/ 0.1-0.15 pH units > normal cells and 0.3 pH units > acute low pH cells. 3) Survival at 42.0 0 C which differed from both normal and acute low pH cells. The chronic culture was still quite sensitive to 42.0 0 C treatments during the first 5 hr, but developed tolerance at a higher level than cells under acute low pH conditions. The pH/sub i/ of the chronic culture responded to 42.0 0 C heating in a manner similar to that for acute low pH cells. Whether this culture represents a normal response to long term low pH exposure, or was the response of a mutant population is at the present unknown

  9. Photolysis of 5-bromouracil and some related compounds in solution. Pt. 6

    International Nuclear Information System (INIS)

    Campbell, J.M.; Sonntag, C. von; Schulte-Frohlinde, D.

    1974-01-01

    The steady state photolysis of 5-bromouracil (BU) in aqueous solution has been studied as a function of wavelength, pH, temperature, and hydrogen-donor concentration. Under all conditions studied, the primary reaction is shown to be C-Br bond cleavage followed by abstraction from the hydrogen-donor to give uracil and HBr. At pH > 12 further products are formed. In deoxygenated aqueous solution at pH 6, 20 0 C, and 254 nm, the quantum yield of BU consumption, PHI (-BU), is 1.8 x 10 -3 independent of hydrogen-donor type or concentration (e.g. 3 x 10 -2 to 2 m MeOH). With increasing pH, PHI (-BU) increases stepwise to 0.012 at pH 10 and to 0.28 at pH 14. pK-values calculated from these data are the same as ground state pK values. The results have been explained in terms of a homolytic dissociation of the C-Br bond of the excited BU followed by recombination or H atom abstraction by the radicals. At high hydrogen-donor concentration H atom abstraction can compete with cage recombination. A comparison has been made between BU photolysis in organic, hydrogen-donor solvents and BU photolysis within the DNA of bacteria or phages. (orig./HK) [de

  10. Gelatin behaviour in dilute aqueous solution : designing a nanoparticulate formulation

    OpenAIRE

    Farrugia, Claude; Groves, Michael J.

    1999-01-01

    Although it has been claimed that nanoparticles can be produced from gelatin, a naturally occurring polypeptide, the commercial conversion of animal collagen to gelatin results in a heterogeneous product with a wide molecular-weight range. This is probably responsible for the widely observed variation in the experimental conditions required for nanoparticle formation. In this study, 0.2% w/v aqueous B225 gelatin solutions were incubated under various conditions of time, temperature, pH an...

  11. An in situ Fourier transform infrared spectroelectrochemical study on ethanol electrooxidation on Pd in alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xiang; Wang, Lianqin; Shen, Pei Kang [The State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou 510275 (China); Cui, Guofeng [School of Chemistry and Chemical Engineering, Sun Yat-Sen University, Guangzhou 510275 (China); Bianchini, Claudio [Istituto di Chimica dei Composti Organometallici (ICCOM-CNR), via Madonna del Piano 10, 50019 Sesto Fiorentino (Italy)

    2010-03-01

    The mechanism of ethanol electrooxidation on a palladium electrode in alkaline solution (from 0.01 to 5 M NaOH) has been investigated by cyclic voltammetry and in situ Fourier transform infrared spectroelectrochemistry. The electrode performance has been found to depend on the pH of the fuel solution. The best performance was observed in 1 M NaOH solution (pH = 14), while the electrochemical activity decreased by either increasing or decreasing the NaOH concentration. In situ FTIR spectroscopic measurements showed the main oxidation product to be sodium acetate at NaOH concentrations higher than 0.5 M. The C-C bond cleavage of ethanol, put in evidence by the formation of CO{sub 2}, occurred at pH values {<=}13. In these conditions, however, the catalytic activity for ethanol oxidation was quite low. No CO formation was detected along the oxidation of ethanol by FTIR spectroscopy. (author)

  12. Differential Sensor for PH Monitoring of Environmental Objects

    Directory of Open Access Journals (Sweden)

    Romanenko Sergey

    2016-01-01

    Full Text Available Differential pH sensor is proposed. Reference electrode and measuring electrode are the same type. Reference electrode is immersed in standard buffer solution with known pH value. The differential pH sensor has longer service life as compared with the traditionally used sensors with silver chloride reference electrode. Ultrasonic cleaning system is proposed to clean the primary measuring transducer from pollution that form as result of silting during long-term operation with the sensor.

  13. TRANSFORMATION OF PB(II FROM CERRUSITE TO CHLOROPYROMORPHITE IN THE PRESENCE OF HYDROXYAPATITE UNDER VARYING CONDITIONS OF PH

    Science.gov (United States)

    The soluble Pb concentration and formation of chloropyromorphite [Pb5(PO4)3Cl] were monitored during the reaction of cerrusite (PbCO3), a highly bioavailable soil Pb species, and hydroxyapatite [Ca5(PO4)3OH] at various P/Pb molar ratios under constant and dynamic pH conditions. ...

  14. Effects of Soil Oxygen Conditions and Soil pH on Remediation of DDT-contaminated Soil by Laccase from White Rot Fungi

    Directory of Open Access Journals (Sweden)

    Yuechun Zhao

    2010-04-01

    Full Text Available High residues of DDT in agricultural soils are of concern because they present serious threats to food security and human health. This article focuses on remediation of DDT-contaminated soil using laccase under different soil oxygen and soil pH conditions. The laboratory experiment results showed significant effects of soil oxygen conditions and soil pH on remediation of DDT-contaminated soil by laccase at the end of a 25-d incubation period. This study found the positive correlation between the concentration of oxygen in soil and the degradation of DDT by laccase. The residue of DDTs in soil under the atmosphere of oxygen decreased by 28.1% compared with the atmosphere of nitrogen at the end of the incubation with laccase. A similar pattern was observed in the remediation of DDT-contaminated soil by laccase under different flooding conditions, the higher the concentrations of oxygen in soil, the lower the residues of four DDT components and DDTs in soils. The residue of DDTs in the nonflooding soil declined by 16.7% compared to the flooded soil at the end of the incubation. The residues of DDTs in soils treated with laccase were lower in the pH range 2.5–4.5.

  15. Study of fatigue crack nucleation in 12% chromium stainless steel in sulphate and phosphate solutions

    International Nuclear Information System (INIS)

    Shalaby, H.M.; Begley, J.A.; Macdonald, D.D.

    1989-01-01

    The morphology of fatigue crack nucleation has been studied in 12%Cr stainless steel at a single stress level of 448 MN m -2 in deaerated H 2 SO 4 -Na 2 SO 4 -NaOH ([SO 4 2- ] = 0.01M and 1M) and in H 3 PO 4 -NaOH ([PO 4 3- ] = 0.01M and 1M) solutions at pH 2, 7 and 10 at 100 0 C. In sulphate solutions at pH 2, the specimen suffered overall surface attack without the initiation of microcracks. The surface attack intensified at the prior austenite grain boundaries, martensite platelet boundaries, and non-metallic inclusions. In contrast, cracks initiated transgranularly in sulphate solutions at pH 7 and 10 with the development of selective attack at crack sites at later stages in the fatigue life. This attack was ascribed to local acidification as a result of hydrolysis of corrosion products extruded from inside the cracks. Long cracks with crack branching and debonded zones were observed in all phosphate solutions, except in 0.01M phosphate solution at pH 7. In this latter environment, short intrusion-extrusion microcracks were observed. This difference in behaviour was attributed to changes in the characteristics of the passive film as influenced by the local environmental conditions, mechanical rupture by plastic deformation, and electrochemical differences at the metal surface. (author)

  16. Solution-mediated phase transformation of haloperidol mesylate in the presence of sodium lauryl sulfate.

    Science.gov (United States)

    Greco, Kristyn; Bogner, Robin

    2011-09-01

    Forming a salt is a common way to increase the solubility of a poorly soluble compound. However, the solubility enhancement gained by salt formation may be lost due to solution-mediated phase transformation (SMPT) during dissolution. The SMPT of a salt can occur due to a supersaturated solution near the dissolving surface caused by pH or other solution conditions. In addition to changes in pH, surfactants are also known to affect SMPT. In this study, SMPT of a highly soluble salt, haloperidol mesylate, at pH 7 in the presence of a commonly used surfactant, sodium lauryl sulfate (SLS), was investigated. Dissolution experiments were performed using a flow-through dissolution apparatus with solutions containing various concentrations of SLS. Compacts of haloperidol mesylate were observed during dissolution in the flow-through apparatus using a stereomicroscope. Raman microscopy was used to characterize solids. The dissolution of haloperidol mesylate was significantly influenced by the addition of sodium lauryl sulfate. In conditions where SMPT was expected, the addition of SLS at low concentrations (0.1-0.2 mM) reduced the dissolution of haloperidol mesylate. In solutions containing concentrations of SLS above the critical micelle concentration (CMC) (10-15 mM), the dissolution of haloperidol mesylate increased compared to below the CMC. The solids recovered from solubility experiments of haloperidol mesylate indicated that haloperidol free base precipitated at all concentrations of SLS. Above 5 mM of SLS, Raman microscopy suggested a new form, perhaps the estolate salt. The addition of surfactant in solids that undergo solution-mediated phase transformation can add complexity to the dissolution profiles and conversion.

  17. Influence of phosphates when uranium in solutions obtained by attacking Forez with sulfuric acid is precipitated by the action of lime; Influence des phosphates, lors de la precipitation par la chaux, de l'uranium contenu dans les solutions d'attaque sulfurique du Forez

    Energy Technology Data Exchange (ETDEWEB)

    Brebec, G

    1959-03-01

    Influence of phosphates when uranium in solutions obtained by attacking Forez with sulfuric acid is precipitated by the action of lime was studied. Most of the phosphates were eliminated in the form of ferric phosphates without noticeable losses of uranium: for this it is only necessary to add sufficient ferric sulfate to the solution to be treated so that [Po{sub 4}{sup 3-}]/[Fe{sup 3+}] {approx} 0,4. In these conditions, the preparation of a calcium concentrate rich in uranium takes place in two stages. The first is neutralization at pH 2,7 to 2,8 with elimination of phosphates, sulfates and iron; the second is precipitation of the concentrate at pH 6,5. (author) [French] Nous avons reussi a eliminer la majeure partie des phosphates sous forme de phosphates ferriques, sans pertes sensibles d'uranium. Pour cela, il suffit d'ajouter a la solution a traiter, du sulfate ferrique en quantite telle que: (Po{sub 4}{sup 3-}]/[Fe{sup 3+}] {approx} 0,4. Dans ces conditions, la preparation du concentre calcique, riche en uranium, s'effectue normalement en deux temps: 1) preneutralisation a pH 2,7-2,8: elimination des sulfates, phosphates et fer; 2) precipitation du concentre a pH 6,5. (auteur)

  18. Colorimetric study of malvidin-3-O-glucoside copigmented by phenolic compounds: The effect of molar ratio, temperature, pH, and ethanol content on color expression of red wine model solutions.

    Science.gov (United States)

    Zhang, Bo; Yang, Xue-Shan; Li, Ning-Ning; Zhu, Xia; Sheng, Wen-Jun; He, Fei; Duan, Chang-Qing; Han, Shun-Yu

    2017-12-01

    In the recent research, the copigmentations of malvidin-3-O-glucoside with eight types of phenolic copigments have been investigated. The influence of the pigment/copigment molar ratio, the reaction temperature, the pH and the ethanol content of solutions has been examined. The results showed that the copigmentation effect was dependent on not only the particular structures of the phenolic compounds but also the factors of the reaction systems. The increase of the copigment concentration can strengthen the copigmentation effect, improve the solution color, and enhance the red-purple features. Different temperatures had different influences on the copigmentation reactions. The destruction of the copigmentation complexes can result in the hypsochromic shift of the reaction solution when the temperature was higher than 20°C. The bathochromic shift of the solution gradually progressed with the increase of the pH value. A significant copigmentation feature was spotted when pH reached 3.0, which demonstrates obvious red-purple characterization. The addition of the ethanol weakened the copigmentation effect. According to measurement through color analysis, it was found that the color differences caused by ethanol in red wine were typically attributed to quantitative changes. Remarkably, all of the above delicate color deviations caused by the structural or environmental factors can be precisely and conveniently depicted via the CIELAB space analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Salt-specific effects in lysozyme solutions

    Directory of Open Access Journals (Sweden)

    T. Janc

    2016-03-01

    Full Text Available The effects of additions of low-molecular-mass salts on the properties of aqueous lysozyme solutions are examined by using the cloud-point temperature, T_{cloud}, measurements. Mixtures of protein, buffer, and simple salt in water are studied at pH=6.8 (phosphate buffer and pH=4.6 (acetate buffer. We show that an addition of buffer in the amount above I_{buffer} = 0.6 mol dm^{-3} does not affect the T_{cloud} values. However, by replacing a certain amount of the buffer electrolyte by another salt, keeping the total ionic strength constant, we can significantly change the cloud-point temperature. All the salts de-stabilize the solution and the magnitude of the effect depends on the nature of the salt. Experimental results are analyzed within the framework of the one-component model, which treats the protein-protein interaction as highly directional and of short-range. We use this approach to predict the second virial coefficients, and liquid-liquid phase diagrams under conditions, where T_{cloud} is determined experimentally.

  20. Impacts of operating conditions and solution chemistry on osmotic membrane structure and performance

    KAUST Repository

    Wong, Mavis C.Y.; Martinez, Kristina; Ramon, Guy Z.; Hoek, Eric M.V.

    2012-01-01

    Herein, we report on changes in the performance of a commercial cellulose triacetate (CTA) membrane, imparted by varied operating conditions and solution chemistries. Changes to feed and draw solution flow rate did not significantly alter the CTA membrane's water permeability, salt permeability, or membrane structural parameter when operated with the membrane skin layer facing the draw solution (PRO-mode). However, water and salt permeability increased with increasing feed or draw solution temperature, while the membrane structural parameter decreased with increasing draw solution, possibly due to changes in polymer intermolecular interactions. High ionic strength draw solutions may de-swell the CTA membrane via charge neutralization, which resulted in lower water permeability, higher salt permeability, and lower structural parameter. This observed trend was further exacerbated by the presence of divalent cations which tends to swell the polymer to a greater extent. Finally, the calculated CTA membrane's structural parameter was lower and less sensitive to external factors when operated in PRO-mode, but highly sensitive to the same factors when the skin layer faced the feed solution (FO-mode), presumably due to swelling/de-swelling of the saturated porous substructure by the draw solution. This is a first attempt aimed at systematically evaluating the changes in performance of the CTA membrane due to operating conditions and solution chemistry, shedding new insight into the possible advantages and disadvantages of this material in certain applications. © 2011 Elsevier B.V.

  1. Impacts of operating conditions and solution chemistry on osmotic membrane structure and performance

    KAUST Repository

    Wong, Mavis C.Y.

    2012-02-01

    Herein, we report on changes in the performance of a commercial cellulose triacetate (CTA) membrane, imparted by varied operating conditions and solution chemistries. Changes to feed and draw solution flow rate did not significantly alter the CTA membrane\\'s water permeability, salt permeability, or membrane structural parameter when operated with the membrane skin layer facing the draw solution (PRO-mode). However, water and salt permeability increased with increasing feed or draw solution temperature, while the membrane structural parameter decreased with increasing draw solution, possibly due to changes in polymer intermolecular interactions. High ionic strength draw solutions may de-swell the CTA membrane via charge neutralization, which resulted in lower water permeability, higher salt permeability, and lower structural parameter. This observed trend was further exacerbated by the presence of divalent cations which tends to swell the polymer to a greater extent. Finally, the calculated CTA membrane\\'s structural parameter was lower and less sensitive to external factors when operated in PRO-mode, but highly sensitive to the same factors when the skin layer faced the feed solution (FO-mode), presumably due to swelling/de-swelling of the saturated porous substructure by the draw solution. This is a first attempt aimed at systematically evaluating the changes in performance of the CTA membrane due to operating conditions and solution chemistry, shedding new insight into the possible advantages and disadvantages of this material in certain applications. © 2011 Elsevier B.V.

  2. Biological and analytical studies of peritoneal dialysis solutions

    Directory of Open Access Journals (Sweden)

    N. Hudz

    2018-04-01

    Full Text Available The purpose of our work was to conduct biological and analytical studies of the peritoneal dialysis (PD solutions containing glucose and sodium lactate and establish correlations between cell viability of the Vero cell line and values of analytical indexes of the tested solutions. The results of this study confirm the cytotoxicity of the PD solutions even compared with the isotonic solution of sodium chloride, which may be due to the low pH of the solutions, presence of glucose degradation products (GDPs and high osmolarity of the solutions, and unphysiological concentrations of glucose and sodium lactate. However, it is not yet known what factors or their combination and to what extent cause the cytotoxicity of PD solutions. In the neutral red (NR test the weak, almost middle (r = -0.496 and 0.498, respectively and unexpected correlations were found between reduced viability of monkey kidney cells and increased pH of the PD solutions and between increased cell viability and increased absorbance at 228 nm of the tested PD solutions. These two correlations can be explained by a strong correlation (r = -0.948 between a decrease in pH and an increase in the solution absorbance at 228 nm. The opposite effect was observed in the MTT test. The weak, but expected correlations (r = 0.32 and -0.202, respectively were found between increased cell viability and increased pH in the PD solutions and between decreased cell viability and increased absorbance at 228 nm of the tested PD solutions. The middle and weak correlations (r = 0.56 and 0.29, respectively were detected between increased cell viability and increased lactate concentration in the NR test and MTT test. The data of these correlations can be partially explained by the fact that a correlation with a coefficient r = -0.34 was found between decreased pH in the solutions and increased lactate concentration. The very weak correlations (0.138 and 0.196, respectively were found between increased cell

  3. Electrochemical characteristics of bioresorbable binary MgCa alloys in Ringer's solution: Revealing the impact of local pH distributions during in-vitro dissolution

    Energy Technology Data Exchange (ETDEWEB)

    Mareci, D., E-mail: danmareci@yahoo.com [Faculty of Chemical Engineering and Environmental Protection, The “Gheorghe Asachi” Technical University of Iasi, 700050, Iasi (Romania); Bolat, G. [Faculty of Chemical Engineering and Environmental Protection, The “Gheorghe Asachi” Technical University of Iasi, 700050, Iasi (Romania); Izquierdo, J. [Department of Chemistry, University of La Laguna, P.O. Box 456, E-38200 La Laguna (Tenerife) (Spain); Crimu, C.; Munteanu, C. [Faculty of Mechanical Engineering, The “Gheorghe Asachi” Technical University of Iasi, 700050, Iasi (Romania); Antoniac, I. [Faculty of Materials Science and Engineering, Politehnica of Bucharest, 060042 Bucharest (Romania); Souto, R.M., E-mail: rsouto@ull.es [Department of Chemistry, University of La Laguna, P.O. Box 456, E-38200 La Laguna (Tenerife) (Spain); Faculty of Materials Science and Engineering, Politehnica of Bucharest, 060042 Bucharest (Romania)

    2016-03-01

    Biodegradable magnesium–calcium (MgCa) alloy is a very attractive biomaterial. Two MgCa alloys below the solid solubility of Ca were considered, as to solely investigate the effect of Ca content on the behavior of magnesium and the pH changes associated to metal dissolution. X-ray diffraction analysis and optical microscopy showed that both Mg–0.63Ca and Mg–0.89Ca alloys were solely composed of α(Mg) phase. Degradation characteristics and electrochemical characterization of MgCa alloys were investigated during exposure to Ringer's solution at 37 °C by electrochemical impedance spectroscopy and scanning electrochemical microscopy. The impedance behavior showed both capacitive and inductive features that are related to the alloy charge transfer reaction and the relaxation of the absorbed corrosion compounds, and can be described in terms of an equivalent circuit. Scanning electron microscopy (SEM) was employed to view the surface morphology of the MgCa samples after 1 week immersion in Ringer's solution showing extensive precipitation of corrosion products, whereas the substrate shows evidence of a non-uniform corrosion process. Energy dispersive analysis showed that the precipitates contained oxygen, calcium, magnesium and chlorine, and the Mg:Ca ratios were smaller than in the alloys. Scanning electrochemical microscopy (SECM) was used to visualize local pH changes associated to these physicochemical processes with high spatial resolution. The occurrence of pH variations in excess of 3 units between anodic and cathodic half-cell reactions was monitored in situ. - Highlights: • Spontaneous degradation of MgCa alloys in Ringer's solution characterized at 37 °C • Reactivity differences between Mg0.63Ca and Mg0.89Ca are evidenced using multiscale electrochemical characterization. • Electrochemical activation occurs heterogeneously on the alloy surface. • Metal dissolution is accompanied by local pH changes. • Mg0.63Ca degrades faster

  4. A thermodynamic model of the hydrolysis of microcline in acid sulfate solutions

    Energy Technology Data Exchange (ETDEWEB)

    Dedolph, R.E.; Parry, W.T.

    1976-12-01

    A theoretical model of the hydrolysis of microcline by a hydrothermal solution has been determined for a closed system at constant temperature. Hypothetical solution compositions and temperatures were chosen to match the known geothermal system at Roosevelt Hot Springs, Utah. The calculated reaction paths indicate that the overall reaction process is an exchange of potassium from the reactant mineral, microcline, for hydrogen from the solution. Aluminum is nearly conserved among solid phases. The amount of microcline reacted per kilogram of solution before overall equilibrium is reached is a function of temperature and initial solution pH. Since the system is closed and at constant temperature natural conditions are not reproduced well enough to apply the model as a geothermometer. The reaction paths suggest qualitative models of alteration mineral zoning patterns that are similar to zoning at Roosevelt Hot Springs, utah; Steamboat Springs, Nevada, and Butte, Montana. The models presented view alteration zoning as a function of temperature and pH gradients within homogeneous host rocks where microcline and quartz are abundant.

  5. Enhanced electrochemomechanical activity of polyaniline films towards high pH region: contribution of Donnan effect

    International Nuclear Information System (INIS)

    Takashima, Wataru; Nakashima, Megumi; Pandey, Shyam S.; Kaneto, Keiichi

    2004-01-01

    Enhancement of electrochemomechanical deformation (ECMD) and expansion of ECMD activity towards high pH have been simultaneously achieved in the electrolytes equilibrated with HCl and NaCl solutions for polyaniline (PANI) film. The maximum deformation has been reached to 6.7% in the mixture of 3 M HCl and 3 M NaCl equilibrated at pH 3 at ambient temperature. By comparing the fact that the ECMD magnitude is 3.2% in 1 M HCl equilibrated at pH 0.5, the simple judicious selection of electrolyte condition leads to the enhancement of ECMD magnitude by around two times. The concentration dependence on both electrical conductivity and absorption spectra elucidates the increase of protonation ratio as a function of electrolyte concentration. The results indicate that the high concentration retains both the electrochemical and ECMD activities in PANI film towards high pH region, which is the enhanced functionality of PANI supported by Donnan effect

  6. Water balance creates a threshold in soil pH at the global scale

    Science.gov (United States)

    Slessarev, E. W.; Lin, Y.; Bingham, N. L.; Johnson, J. E.; Dai, Y.; Schimel, J. P.; Chadwick, O. A.

    2016-12-01

    Soil pH regulates the capacity of soils to store and supply nutrients, and thus contributes substantially to controlling productivity in terrestrial ecosystems. However, soil pH is not an independent regulator of soil fertility—rather, it is ultimately controlled by environmental forcing. In particular, small changes in water balance cause a steep transition from alkaline to acid soils across natural climate gradients. Although the processes governing this threshold in soil pH are well understood, the threshold has not been quantified at the global scale, where the influence of climate may be confounded by the effects of topography and mineralogy. Here we evaluate the global relationship between water balance and soil pH by extracting a spatially random sample (n = 20,000) from an extensive compilation of 60,291 soil pH measurements. We show that there is an abrupt transition from alkaline to acid soil pH that occurs at the point where mean annual precipitation begins to exceed mean annual potential evapotranspiration. We evaluate deviations from this global pattern, showing that they may result from seasonality, climate history, erosion and mineralogy. These results demonstrate that climate creates a nonlinear pattern in soil solution chemistry at the global scale; they also reveal conditions under which soils maintain pH out of equilibrium with modern climate.

  7. Zn(II, Mn(II and Sr(II Behavior in a Natural Carbonate Reservoir System. Part I: Impact of Salinity, Initial pH and Initial Zn(II Concentration in Atmospheric Conditions

    Directory of Open Access Journals (Sweden)

    Auffray B.

    2016-07-01

    Full Text Available The sorption of inorganic elements on carbonate minerals is well known in strictly controlled conditions which limit the impact of other phenomena such as dissolution and/or precipitation. In this study, we evidence the behavior of Zn(II (initially in solution and two trace elements, Mn(II and Sr(II (released by carbonate dissolution in the context of a leakage from a CO2 storage site. The initial pH chosen are either equal to the pH of the water-CO2 equilibrium (~ 2.98 or equal to the pH of the water-CO2-calcite system (~ 4.8 in CO2 storage conditions. From this initial influx of liquid, saturated or not with respect to calcite, the batch experiments evolve freely to their equilibrium, as it would occur in a natural context after a perturbation. The batch experiments are carried out on two natural carbonates (from Lavoux and St-Emilion with PCO2 = 10−3.5 bar, with different initial conditions ([Zn(II]i from 10−4 to 10−6 M, either with pure water or 100 g/L NaCl brine. The equilibrium regarding calcite dissolution is confirmed in all experiments, while the zinc sorption evidenced does not always correspond to the two-step mechanism described in the literature. A preferential sorption of about 10% of the concentration is evidenced for Mn(II in aqueous experiments, while Sr(II is more sorbed in saline conditions. This study also shows that this preferential sorption, depending on the salinity, is independent of the natural carbonate considered. Then, the simulations carried out with PHREEQC show that experiments and simulations match well concerning the equilibrium of dissolution and the sole zinc sorption, with log KZn(II ~ 2 in pure water and close to 4 in high salinity conditions. When the simulations were possible, the log K values for Mn(II and Sr(II were much different from those in the literature obtained by sorption in controlled conditions. It is shown that a new conceptual model regarding multiple Trace Elements (TE sorption is

  8. Effect of environmental and cultural conditions on medium pH and explant growth performance of Douglas-fir (Pseudotsuga menziesii shoot cultures [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Chien-Chih Chen

    2015-05-01

    Full Text Available The medium pH level of plant tissue cultures has been shown to be essential to many aspects of explant development and growth. Sensitivity or tolerance of medium pH change in vitro varies according to specific requirements of individual species. The objectives of this study are to 1 determine medium pH change over time in storage conditions and with presence of explants, 2 evaluate the effects of medium pH change on explant growth performance and 3 assess the effects of adding a pH stabilizer, 2-(N-morpholinoethanesulfonic acid (MES that is commonly used in Douglas-fir micropropagation medium. Vegetative buds were collected in the spring before breaking dormancy from juvenile and mature donor trees for conducting these evaluations. Medium, with or without MES, was pre-adjusted to five pH levels before adding MES, agar and autoclaving. Medium pH changes and explant growth parameters were measured at eight different incubation times. Overall, MES provided a more stable medium pH, relative to starting pH values, under both light and dark storage conditions as well as with presence of explants. A general trend of decreasing medium pH over time was found comparing explants from juvenile and mature donor genotypes. Explant height and weight growth increased over time, but differ among explants from juvenile and mature donor genotypes. Our findings suggest that a 21-day subculture practice may best sustain medium freshness, medium pH level and desirable explant growth.

  9. Adsorption of Chromium from Aqueous Solution Using Polyaniline

    Directory of Open Access Journals (Sweden)

    Majid Riahi Samani

    2011-10-01

    Full Text Available New group of polymers have been synthesized that are conductive of electricity so they are called conducting polymers. One of the most conducting polymers is "polyaniline". In the present study, polyaniline was synthesized by oxidizing aniline monomer under strongly acidic conditions using potassium iodate as an initiator of oxidative polymerization. Synthesized polyaniline as a powder used as an adsorbent to remove chromium from aqueous solution. Experiments were conducted in batch mode with variables such as amount of polyaniline, chromium solution pH and adsorbtion isotherms. Due to presence of Cr (III in solution after using polyaniline, removal mechanism is the combination of surface adsorption and reduction. It seems that polyaniline reduces the Cr(VI to Cr(III and adsorbs the Cr(III and a part of remaining  Cr(VI. It is well known that nitrogen atom in compounds of amine derivative makes co-ordinate bond with positive charge of metals due to the presence of electron in sp3 orbital of nitrogen. The majority of total chromium removal  occurred at 30minute for polyaniline  and the optimum  time for  hexavalent chromium  removal was about 5 min. Polyaniline has the maximum total cheomiume removal at pH, 3-9. The maximum hexavalent chromium removal occurred at acidic pH for polyanilines. The equilibrium adsorption data for polyaniline fitted both Freundlich’s and Langmuir’s isotherms. This research shows that polyaniline can be used as an adsorbent  for removal chromium from aqueous solution.

  10. Formation of Hg(II) Tetrathiolate Complexes with Cysteine at Neutral pH.

    Science.gov (United States)

    Warner, Thomas; Jalilehvand, Farideh

    2016-04-01

    Mercury(II) ions precipitate from aqueous cysteine (H 2 Cys) solutions containing H 2 Cys/Hg(II) mole ratio ≥ 2.0 as Hg( S -HCys) 2 . In absence of additional cysteine, the precipitate dissolves at pH ~12 with the [Hg( S,N -Cys) 2 ] 2- complex dominating. With excess cysteine (H 2 Cys/Hg(II) mole ratio ≥ 4.0), higher complexes form and the precipitate dissolves at lower pH values. Previously, we found that tetrathiolate [Hg( S -Cys) 4 ] 6- complexes form at pH = 11.0; in this work we extend the investigation to pH values of physiological interest. We examined two series of Hg(II)-cysteine solutions in which C Hg(II) varied between 8 - 9 mM and 80 - 100 mM, respectively, with H 2 Cys/Hg(II) mole ratios from 4 to ~20. The solutions were prepared in the pH range 7.1 - 8.8, at the pH at which the initial Hg( S -HCys) 2 precipitate dissolved. The variations in the Hg(II) speciation were followed by 199 Hg NMR, X-ray absorption and Raman spectroscopic techniques. Our results show that in the dilute solutions ( C Hg(II) = 8 - 9 mM), mixtures of di-, tri- (major) and tetrathiolate complexes exist at moderate cysteine excess ( C H2Cys ~ 0.16 M) at pH 7.1. In the more concentrated solutions ( C Hg(II) = 80 - 100 mM) with high cysteine excess ( C H2Cys > 0.9 M), tetrathiolate [Hg( S -cysteinate) 4 ] m -6 ( m = 0 - 4) complexes dominate in the pH range 7.3 - 7.8, with lower charge than for the [Hg( S -Cys) 4 ] 6- complex due to protonation of some ( m ) of the amino groups of the coordinated cysteine ligands. The results of this investigation could provide a key to the mechanism of biosorption and accumulation of Hg(II) ions in biological / environmental systems.

  11. Solution chemistry of lanthanide complexes

    International Nuclear Information System (INIS)

    Brittain, H.G.

    1979-01-01

    Intermolecular energy transfer from Tb 3+ to Eu 3+ , luminescence intensity measurements, potentiometric titrations, differential absorption spectroscopy, and spectroscopic titrations were all used to study the binding of lanthanide ions by serine and threonine. At low pH (3.0 to 6.0) the complexes are mononuclear and ligand is only weakly bound. In the pH interval of 6.0 to 8.5 stronger interaction takes place between the ligand and the metal (with possible coordination of the undissociated hydroxyl group), and self-association of complexes becomes important. Above pH 8.5, base hydrolysis of the complexes leads to highly associated species in solution and shortly above this pH an insoluble precipitate is formed. It was found that energy could be transferred from Tb 3+ to Eu 3+ more efficiently among complexes prepared from racemic ligands than in complexes made from resolved ligand, but this stereoselectivity was only observed at pH values greater than 6.5 and in solutions having a 1:10 ratio of metal-to-ligand. No stereoselectivity was found in solutions having 1:5 ratios, and this observation was explained by the existence of 1:2 metal-ligand complexes existing in solutions having the higher ratio of metal-to-ligand (only 1:1 complexes are then found at lower ratios of metal-to-ligand). (author)

  12. Shock-jump conditions in a general medium: weak-solution approach

    Science.gov (United States)

    Forbes, L. K.; Krzysik, O. A.

    2017-05-01

    General conservation laws are considered, and the concept of a weak solution is extended to the case of an equation involving three space variables and time. Four-dimensional vector calculus is used to develop general jump conditions at a shock wave in the material. To illustrate the use of this result, jump conditions at a shock in unsteady three-dimensional compressible gas flow are presented. It is then proved rigorously that these reduce to the commonly assumed conditions in coordinates normal and tangential to the shock face. A similar calculation is also outlined for an unsteady three-dimensional shock in magnetohydrodynamics, and in a chemically reactive fluid. The technique is available for determining shock-jump conditions in quite general continuous media.

  13. The pH profile for acid-induced elongation of coleoptile and epicotyl sections is consistent with the acid-growth theory

    Science.gov (United States)

    Cleland, R. E.; Buckley, G.; Nowbar, S.; Lew, N. M.; Stinemetz, C.; Evans, M. L.; Rayle, D. L.

    1991-01-01

    The acid-growth theory predicts that a solution with a pH identical to that of the apoplast of auxin-treated tissues (4.5.-5.0) should induce elongation at a rate comparable to that of auxin. Different pH profiles for elongation have been obtained, however, depending on the type of pretreatment between harvest of the sections and the start of the pH-incubations. To determine the acid sensitivity under in vivo conditions, oat (Avena sativa L.) coleoptile, maize (Zea mays L.) coleoptile and pea (Pisum sativum L.) epicotyl sections were abraded so that exogenous buffers could penetrate the free space, and placed in buffered solutions of pH 3.5-6.5 without any preincubation. The extension, without auxin, was measured over the first 3 h. Experiments conducted in three laboratories produced similar results. For all three species, sections placed in buffer without pretreatment elongated at least threefold faster at pH 5.0 than at 6.0 or 6.5, and the rate elongation at pH 5.0 was comparable to that induced by auxin. Pretreatment of abraded sections with pH-6.5 buffer or distilled water adjusted to pH 6.5 or above gave similar results. We conclude that the pH present in the apoplast of auxin-treated coleoptile and stems is sufficiently low to account for the initial growth response to auxin.

  14. Evaluating high pH for control of dreissenid mussels

    Directory of Open Access Journals (Sweden)

    Dave Evans

    2013-04-01

    Full Text Available Two field experiments were carried out using a custom built flow-through laboratory to test the effect of elevated pH on dreissenid musselsas a potential control method. Both experiments tested the ability of dreissenid pediveligers to settle under conditions of elevated pH and thelong-term survival of adult dreissenids under the same conditions. The two experimental sites had different water quality and differentspecies of dreissenids present. The settlement of quagga mussel pediveligers at the lower Colorado River was inhibited with increasing pH.At the maximum achieved pH of 9.1, there was approximately 90% reduction compared to the maximum settlement observed in the controls.Since the settlement was almost as low in pH 8.9 as at pH 9.1, the inhibition in settlement may have been due to the presence of a precipitateformed under high pH conditions rather than the increase in background pH. No mortality of quagga mussel adults was observed in theexperimental pH levels at the lower Colorado River. At San Justo Reservoir, zebra mussel settlement decreased with increasing pH. Newsettlement was almost entirely absent at the highest pH tested (pH 9.6. The observed mortality of adult zebra mussels was low, but did tendto increase with increasing pH. We also tested the response of adult zebra mussels to short-term exposure to very high pH levels (i.e. pH 10,11, and 12. Adult mussels in poor physical condition experienced 90% mortality after 12 hours at pH 12. For unstressed adult zebra mussels,90% mortality was reached after 120 hours at pH 12. Significant mortalities were also observed both at pH 10 and pH 11. From this study,we conclude that pH elevation could be used both as a preventative treatment to eliminate settlement by dreissenid mussels and as an end ofseason treatment to eliminate adults. The high pH treatment would have to be tailored to the site water quality to prevent formation ofprecipitate during treatment and to minimize corrosive

  15. Effect of pH value on particle morphology and electrochemical properties of LiFePO4 by hydrothermal method

    International Nuclear Information System (INIS)

    Song, Qingzhu; Ou, Xiuqin; Wang, Li; Liang, Guangchuan; Wang, Zuorui

    2011-01-01

    Graphical abstract: The pH value of system is adjusted in the range of 2.5-8.8 by using dilute sulfuric acid and ammonia water. The results indicated that the particle exhibits acute angle diamond flake-like morphology at pH = 2.5. With increase of pH value, the particle gradually becomes to round flake-like and irregular flake-like morphology. The optimal sample synthesized at pH = 6.4 exhibits discharge capacities of 151.8 mAh g -1 at 0.2 C rate and 129.3 mAh g -1 at 3 C rate. Highlights: → The pH value of solution affects greatly on particle morphology. → The solubility product determined the transition of interphases. → The disorder of atoms in crystal is affected by pH value. → LiFePO 4 with high capacity could be synthesized at slight acid or neutral conditions. -- Abstract: Lithium iron phosphate was prepared by hydrothermal synthesis using LiOH.H 2 O, FeSO 4 .7H 2 O and H 3 PO 4 as raw materials. The effects of pH value of reaction solution on particle morphology and electrochemical property were investigated. The pH value of the reaction solution was adjusted in the range of 2.5-8.8 by dilute sulfuric acid and ammonia water. The samples were characterized by field-emission scanning electronic microscope (FE-SEM), X-ray powder diffraction (XRD), constant-current charge/discharge cycling tests and chemical analysis. The results indicated that the particles exhibited acute angle diamond flake-like morphology at pH = 2.5, and as the pH value increased, the particle became hexagon flake-like, round flake-like and irregular flake-like morphology gradually. The optimal sample synthesized at pH = 6.4 exhibited discharge capacities of 151.8 mAh g -1 at 0.2 C rate and 129.3 mAh g -1 at 3 C rate. It was found that pH value affected the morphologies and properties of the product by means of different crystal growth rates.

  16. Removal of Co(II) from aqueous solution by using hydroxyapatite

    International Nuclear Information System (INIS)

    Yan Huang; Liang Chen; Hualin Wang

    2012-01-01

    Herein, hydroxyapatite (HAP) was prepared by aqueous precipitation technique and was characterized by using FT-IR and XRD to determine its chemical functional groups and micro-structure. The removal of cobalt from aqueous solution to HAP was studied by batch technique as a function of various environmental parameters such as contact time, pH, ionic strength, foreign ions, fulvic acid (FA), and temperature under ambient conditions. The results indicated that the sorption of Co(II) on HAP was strongly dependent on pH and ionic strength. The presence of FA enhanced the sorption of Co(II) on HAP at low pH, whereas reduced Co(II) sorption on HAP at high pH. The Langmuir, Freundlich and D-R models were used to simulate the sorption isotherms at three different temperatures of 303.15, 323.15 and 343.15 K. The thermodynamic parameters (ΔHdeg, ΔSdeg and ΔGdeg) calculated from the temperature dependent sorption isotherms indicated that the sorption process of Co(II) on HAP was spontaneous and endothermic. The sorption of Co(II) was dominated by outer-sphere surface complexation and ion exchange at low pH, whereas inner-sphere surface complexation or surface precipitation was the main sorption mechanism at high pH values. The results suggest that the HAP is a suitable material in the preconcentration and solidification of Co(II) from large volumes of aqueous solutions. (author)

  17. Ions, metabolites, and cells: Water as a reporter of surface conditions during bacterial growth

    Science.gov (United States)

    Jarisz, Tasha A.; Lane, Sarah; Gozdzialski, Lea; Hore, Dennis K.

    2018-06-01

    Surface-specific nonlinear vibrational spectroscopy, combined with bulk solution measurements and imaging, is used to study the surface conditions during the growth of E. coli. As a result of the silica high surface charge density, the water structure at the silica-aqueous interface is known to be especially sensitive to pH and ionic strength, and surface concentration profiles develop that can be appreciably different from the bulk solution conditions. We illustrate that, in the presence of growing cells, a unique surface micro-environment is established as a result of metabolites accumulating on the silica surface. Even in the subsequent absence of the cells, this surface layer works to reduce the interfacial ionic strength as revealed by the enhanced signal from surface water molecules. In the presence of growing cells, an additional boost in surface water signal is attributed to a local pH that is higher than that of the bulk solution.

  18. Metal release from contaminated coastal sediments under changing pH conditions: Implications for metal mobilization in acidified oceans.

    Science.gov (United States)

    Wang, Zaosheng; Wang, Yushao; Zhao, Peihong; Chen, Liuqin; Yan, Changzhou; Yan, Yijun; Chi, Qiaoqiao

    2015-12-30

    To investigate the impacts and processes of CO2-induced acidification on metal mobilization, laboratory-scale experiments were performed, simulating the scenarios where carbon dioxide was injected into sediment-seawater layers inside non-pressurized chambers. Coastal sediments were sampled from two sites with different contamination levels and subjected to pre-determined pH conditions. Sediment samples and overlying water were collected for metal analysis after 10-days. The results indicated that CO2-induced ocean acidification would provoke increased metal mobilization causing adverse side-effects on water quality. The mobility of metals from sediment to the overlying seawater was correlated with the reduction in pH. Results of sequential extractions of sediments illustrated that exchangeable metal forms were the dominant source of mobile metals. Collectively, our data revealed that high metal concentrations in overlying seawater released from contaminated sediments under acidic conditions may strengthen the existing contamination gradients in Maluan Bay and represent a potential risk to ecosystem health in coastal environments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Adsorption and colloidal behaviour of carrier-free 7Be in aqueous solutions

    International Nuclear Information System (INIS)

    Benes, P.; Jiranek, V.

    1974-01-01

    The state of carrier-free 7 Be in aqueous nitrate solutions was studied by electrophoresis, centrifugation and dialysis. In solutions of pH 2+ cation. At pH > 4 hydrolysis of beryllium proceeds which results in the formation of BeOH + ions and Be(OH) 2 molecules. The larger part of these molecules is adsorbed on the surface of colloidal impurities present in the solution. The pseudocolloids thus formed are positively charged up to pH 11. In alkaline solutions (pH > 11), negatively charged pseudocolloids and anionic hydroxocomplexes of beryllium exist. Adsorption and desorption of carrier-free beryllium was studied on glass, plexiglass and polyethylene as a function of pH, age and ionic strength (NaNO 3 ) of the solution. It has been found that the adsorption begins at pH 3-5, passes through a maximum at pH 8-11 and decreases to a very low value at pH 14. Probable mechanismus of the adsorption were discussed. (orig.) [de

  20. Stability of tacrolimus solutions in polyolefin containers.

    Science.gov (United States)

    Lee, Jun H; Goldspiel, Barry R; Ryu, Sujung; Potti, Gopal K

    2016-02-01

    Results of a study to determine the stability of tacrolimus solutions stored in polyolefin containers under various temperature conditions are reported. Triplicate solutions of tacrolimus (0.001, 0.01, and 0.1 mg/mL) in 0.9% sodium chloride injection or 5% dextrose injection were prepared in polyolefin containers. Some samples were stored at room temperature (20-25 °C); others were refrigerated (2-8 °C) for 20 hours and then stored at room temperature for up to 28 hours. The solutions were analyzed by stability-indicating high-performance liquid chromatography (HPLC) assay at specified time points over 48 hours. Solution pH was measured and containers were visually inspected at each time point. Stability was defined as retention of at least 90% of the initial tacrolimus concentration. All tested solutions retained over 90% of the initial tacrolimus concentration at all time points, with the exception of the 0.001-mg/mL solution prepared in 0.9% sodium chloride injection, which was deemed unstable beyond 24 hours. At all evaluated concentrations, mean solution pH values did not change significantly over 48 hours; no particle formation was detected. During storage in polyolefin bags at room temperature, a 0.001-mg/mL solution of tacrolimus was stable for 24 hours when prepared in 0.9% sodium chloride injection and for at least 48 hours when prepared in 5% dextrose injection. Solutions of 0.01 and 0.1 mg/mL prepared in either diluent were stable for at least 48 hours, and the 0.01-mg/mL tacrolimus solution was also found to be stable throughout a sequential temperature protocol. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  1. Research on ration selection of mixed absorbent solution for membrane air-conditioning system

    International Nuclear Information System (INIS)

    Li, Xiu-Wei; Zhang, Xiao-Song; Wang, Fang; Zhao, Xiao; Zhang, Zhuo

    2015-01-01

    Highlights: • We derive models of the membrane air-conditioning system with mixed absorbents. • We make analysis on system COP, cost-effectiveness and economy. • The paper provides a new method for ideal absorbent selection. • The solutes concentration of 50% achieves the best cost-effectiveness and the economy. - Abstract: Absorption air-conditioning system is a good alternative to vapor compression system for developing low carbon society. To improve the performance of the traditional absorption system, the membrane air-conditioning system is configured and its COP can reach as high as 6. Mixed absorbents are potential for cost reduction of the membrane system while maintaining a high COP. On the purpose of finding ideal mixed absorbent groups, this paper makes analysis on COP, cost-effectiveness and economy of the membrane system with mixed LiBr–CaCl 2 absorbent solution. The models of the system have been developed for the analysis. The results show the COP is higher for the absorbent groups with lower concentration of the total solute and higher concentration ratio of LiBr. It also reveals when the total solutes concentration is about 50%, it achieves the best cost-effectiveness and the economy. The process of the analysis provides a useful method for mixed absorbents selection

  2. In vitro synthesis and purification of PhIP-deoxyguanosine and PhIP-DNA oligomer covalent complexes

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, J.

    1994-12-01

    2-Amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) is a heterocyclic amine compound formed when meats are cooked at high temperatures. PhIP damages DNA by forming covalent complexes with DNA carcinogen. In an effort to understand how the binding of PhIP to DNA may cause cancer, it is important to characterize the structures of PhIP-damaged DNA molecules. Our HPLC data support fluorescence and {sup 32}P Post-labeling studies which indicate the formation of several species of 2{prime}deoxyguanosine-(dG) or oligodeoxynucleotide-PhIP adducts. The reaction of PhIP with dG resulted in a reddish precipitate that was likely the major adduct, N-(deoxyguanosin-8-yl)-PhIP (dG-C8-PhIP) adduct, with a more polar adduct fraction remaining in the supernatant. Reversed-phase HPLC analysis of the adducts in the supernatant revealed the existence of species of much shorter retention times than the dG-C8-PhIP adduct, confirming that these species are more polar than dG-C8-PhIP. At least four adducts were formed in the reaction of PhIP with DNA oligomer. HPLC analysis of the PhIP-DNA oligomer supernatant after butanol extractions revealed four unresolved peaks which spectra had maximum wavelengths between 340 and 360 nm. Though adduct peaks were not completely resolved, there was {approximately}3 minutes interval between the DNA oligomer peak and the adduct peaks. Furthermore, fluorescence emission data of the DNA oligomer-PhIP adduct solution show heterogeneous binding. The more polar PhIP adducts were fraction-collected and their structures will be solved by nuclear magnetic resonance or x-ray crystallography.

  3. Reduction of mercury from mackerel fillet using combined solution of cysteine, EDTA, and sodium chloride.

    Science.gov (United States)

    Hajeb, P; Jinap, S

    2012-06-13

    An acidic solution containing mercury chelating agents to eliminate mercury in raw fish (mackerel) fillet was developed. The solution contained hydrochloric acid, sodium hydroxide, cysteine, EDTA, and NaCl. The optimum conditions for mercury reduction were achieved using response surface methodology (RSM) at cysteine concentration of 1.25%, EDTA of 275 mg/L, NaCl of 0.5%, pH of 3.75, and exposure time of 18 min. The optimized conditions produced a solution which can remove up to 91% mercury from raw fish fillet. Cysteine and EDTA were identified as potential chelating agents with the greatest potential for use. The solution can be employed in fish industries to reduce mercury in highly contaminated fish.

  4. Label-Free Carbon-Dots-Based Ratiometric Fluorescence pH Nanoprobes for Intracellular pH Sensing.

    Science.gov (United States)

    Shangguan, Jingfang; He, Dinggeng; He, Xiaoxiao; Wang, Kemin; Xu, Fengzhou; Liu, Jinquan; Tang, Jinlu; Yang, Xue; Huang, Jin

    2016-08-02

    Measuring pH in living cells is of great importance for better understanding cellular functions as well as providing pivotal assistance for early diagnosis of diseases. In this work, we report the first use of a novel kind of label-free carbon dots for intracellular ratiometric fluorescence pH sensing. By simple one-pot hydrothermal treatment of citric acid and basic fuchsin, the carbon dots showing dual emission bands at 475 and 545 nm under single-wavelength excitation were synthesized. It is demonstrated that the fluorescence intensities of the as-synthesized carbon dots at the two emissions are pH-sensitive simultaneously. The intensity ratio (I475 nm/I545 nm) is linear against pH values from 5.2 to 8.8 in buffer solution, affording the capability as ratiometric probes for intracellular pH sensing. It also displays that the carbon dots show excellent reversibility and photostability in pH measurements. With this nanoprobe, quantitative fluorescence imaging using the ratio of two emissions (I475 nm/I545 nm) for the detection of intracellular pH were successfully applied in HeLa cells. In contrast to most of the reported nanomaterials-based ratiometric pH sensors which rely on the attachment of additional dyes, these carbon-dots-based ratiometric probes are low in toxicity, easy to synthesize, and free from labels.

  5. Plaque pH changes following consumption of two types of plain and bulky bread

    Directory of Open Access Journals (Sweden)

    Shiva Mortazavi

    2011-01-01

    Full Text Available Background: Consistency, backing process and content differences could influence cariogenic potential of foods. The aim was to compare plaque pH changes following consumption of two types of bread with different physical characteristics. Methods : In this clinical trial, interproximal plaque pH of 10 volunteers with high risk of dental caries (saliva Streptococcus mutans > 10 5 , high dental caries experience, and average DMFT =6.10 ± 1.56 was measured. Plain traditionally backed "Sangak bread" and soft bulky "Baguette bread" and %10 sucrose solution were tested in a cross over designed experiment. Baseline plaque pH was recorded and followed by 1, 5, 10, 15, 20, and 30 minutes intervals. Data was analyzed using ANOVA and Tukey test (α = 0.05. Results: Sucrose solution caused the most pronounced pH and ∆pH drop from 7.15 ± 0.33 at baseline to 6.78 ± 0.29. Means plaque pH of 10% sucrose solution and Baguette were not statistically different at 1, 20 and 30 minutes (P > 0.05. Mean plaque pH of Sangak and Baguette showed significant differences at 0, 1, 20 and30 minutes (P < 0.05. Sucrose solution caused a dramatic plaque pH drop during first 10 minutes and then within 30 minutes returned to baseline pH. For two bread samples within first 10 minutes, pH increased and then started to decrease during tenth to fifteenth minutes. Conclusion: During all experiment phases, the mean pH of Baguette with less consistency and carbohydrate content and higher rate of starch gelatination was lower compared to Sangak.

  6. Transport and Retention of TiO2 Rutile Nanoparticles in Saturated Porous Media: Influence of Solution pH, Ionic Strength, and the Presence of Humic Acid

    Science.gov (United States)

    The influence of solution pH, ionic strength, and varying concentrations of the Suwannee River Humic Acid (SRHA) on the transport of titanium dioxide (TiO2, rutile) nanoparticle aggregates (nTiO2) in saturated porous media was investigated through systematically examining the tra...

  7. Influence of Bath Composition at Acidic pH on Electrodeposition of Nickel-Layered Silicate Nanocomposites for Corrosion Protection

    Directory of Open Access Journals (Sweden)

    Jeerapan Tientong

    2013-01-01

    Full Text Available Nickel-layered silicates were electrochemically deposited from acidic bath solutions. Citrate was used as a ligand to stabilize nickel (II ions in the plating solution. The silicate, montmorillonite, was exfoliated by stirring in aqueous solution over 24 hours. The plating solutions were analyzed for zeta-potential, particle size, viscosity, and conductivity to investigate the effects of the composition at various pHs. The solution particles at pH 2.5 (−22.2 mV and pH 3.0 (−21.9 mV were more stable than at pH 1.6 (−10.1 mV as shown by zeta-potential analysis of the nickel-citrate-montmorillonite plating solution. Ecorr for the films ranged from −0.32 to −0.39 V with varying pH from 1.6 to 3.0. The films were immersed in 3.5% NaCl and the open circuit potential monitored for one month. The coatings deposited at pH 3.0 were stable 13 days longer in the salt solution than the other coatings. X-ray diffraction showed a change in the (111/(200 ratio for the coatings at the various pHs. The scanning electron microscopy and hardness results also support that the electrodeposition of nickel-montmorillonite at pH 3.0 (234 GPa had improved hardness and morphology compared to pH 2.5 (174 GPa and pH 1.6 (147 GPa.

  8. Experimental measurements of the solubilities of selected long-lived fission products, activation products and actinide daughters under high pH conditions

    International Nuclear Information System (INIS)

    Pilkington, N.J.; Shadbolt, P.J.; Wilkins, J.D.

    1988-05-01

    Solubility measurements of several elements have been attempted under high pH and oxic conditions in a range of concrete leachates. The elements investigated were niobium, tin, selenium, lead and thorium. (author)

  9. Coral calcifying fluid pH is modulated by seawater carbonate chemistry not solely seawater pH.

    Science.gov (United States)

    Comeau, S; Tambutté, E; Carpenter, R C; Edmunds, P J; Evensen, N R; Allemand, D; Ferrier-Pagès, C; Tambutté, S; Venn, A A

    2017-01-25

    Reef coral calcification depends on regulation of pH in the internal calcifying fluid (CF) in which the coral skeleton forms. However, little is known about calcifying fluid pH (pH CF ) regulation, despite its importance in determining the response of corals to ocean acidification. Here, we investigate pH CF in the coral Stylophora pistillata in seawater maintained at constant pH with manipulated carbonate chemistry to alter dissolved inorganic carbon (DIC) concentration, and therefore total alkalinity (A T ). We also investigate the intracellular pH of calcifying cells, photosynthesis, respiration and calcification rates under the same conditions. Our results show that despite constant pH in the surrounding seawater, pH CF is sensitive to shifts in carbonate chemistry associated with changes in [DIC] and [A T ], revealing that seawater pH is not the sole driver of pH CF Notably, when we synthesize our results with published data, we identify linear relationships of pH CF with the seawater [DIC]/[H + ] ratio, [A T ]/ [H + ] ratio and [[Formula: see text

  10. On the problem of silica solubility at high pH

    International Nuclear Information System (INIS)

    Eikenberg, J.

    1990-07-01

    The aqueous system Na 2 O-H 2 O-SiO 2 is considered to play an important role when strong alkaline pore waters of a cement based intermediate level radioactive waste repository intrude into the rock formations surrounding the near field. Under such conditions unknown quantities of silica may dissolve. Therefore the pH-dependence of the solubility of amorphous silica and quartz is investigated by a parameter variation study using the geochemical speciation code MINEQL/EIR. Published silica solubility data obtained in sodium hydroxide solutions at 25 and 90 o C are compared with the results of four models which use different proposed values of the rather uncertain equilibrium constants. Of main interest is the question of whether, in a high pH region, the silica solubility can be explained with different monomeric species only, or to what extent additional polymeric silica species have to be considered as well. The solubility of amorphous silica at 25 o C is well understood up to a pH of about 10.5, where it is determined by the solubility product and the first dissociation constant of monomeric silic acid. The most probable cause of the increased solubility of amorphous silica in the region between pH 10.5 and 11.3 is the formation of dimers, trimers and tetramers. Below a total silica concentration of 0.001 M and pH ≤ 10.0, however, polymerisation proves to be insignificant. Besides low temperature studies using amorphous silica, the solubility of quartz has also been measured in NaOH solutions at 90 o C. As is the case at lower temperatures, the reported values for the second dissociation constant at 90 o C scatter widely. It can be shown that in a NaOH medium up to 0.1 M only mononuclear silica species are stable. Therefore it is concluded that the trend of monomers to form polymers decreases strongly with temperature. In strong NaOH solutions at elevated temperatures, silica-sodium ion pairing seems to gain importance. (author) 12 figs., 9 tabs., 65 refs

  11. Water-rock interactions and the pH stability of groundwater from Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Ebinger, M.H.

    1992-01-01

    Titrations of acidic solutions in waters from the tuff and carbonate aquifers at Yucca Mountain were simulated using the geochemical codes PHREEQE and EQ3/6. The simulations tested pH stability of the waters in the presence of different minerals and in their absence. Two acidic solutions, 10 -4 HCl and 10 -4 M UO 2 (NO 3 ) 2 , were titrated in to the water. Little pH and/or compositional change resulted in the groundwater when the HCl solution was titrated, but significant pH and CO 2 fugacity changes were observed when UO 2 (NO 3 ) 2 was titrated. Water interactions with alkali feldspar, quartz or cristobalite, and Ca-smectite buffered the pH and compositional changes in the carbonate water and decreased the magnitude of pH and compositional changes when small volumes of UO 2 (NO 3 ) 2 added to the tuffaceous waters

  12. Electrochemical characteristics of bioresorbable binary MgCa alloys in Ringer's solution: Revealing the impact of local pH distributions during in-vitro dissolution.

    Science.gov (United States)

    Mareci, D; Bolat, G; Izquierdo, J; Crimu, C; Munteanu, C; Antoniac, I; Souto, R M

    2016-03-01

    Biodegradable magnesium-calcium (MgCa) alloy is a very attractive biomaterial. Two MgCa alloys below the solid solubility of Ca were considered, as to solely investigate the effect of Ca content on the behavior of magnesium and the pH changes associated to metal dissolution. X-ray diffraction analysis and optical microscopy showed that both Mg-0.63Ca and Mg-0.89Ca alloys were solely composed of α(Mg) phase. Degradation characteristics and electrochemical characterization of MgCa alloys were investigated during exposure to Ringer's solution at 37 °C by electrochemical impedance spectroscopy and scanning electrochemical microscopy. The impedance behavior showed both capacitive and inductive features that are related to the alloy charge transfer reaction and the relaxation of the absorbed corrosion compounds, and can be described in terms of an equivalent circuit. Scanning electron microscopy (SEM) was employed to view the surface morphology of the MgCa samples after 1 week immersion in Ringer's solution showing extensive precipitation of corrosion products, whereas the substrate shows evidence of a non-uniform corrosion process. Energy dispersive analysis showed that the precipitates contained oxygen, calcium, magnesium and chlorine, and the Mg:Ca ratios were smaller than in the alloys. Scanning electrochemical microscopy (SECM) was used to visualize local pH changes associated to these physicochemical processes with high spatial resolution. The occurrence of pH variations in excess of 3 units between anodic and cathodic half-cell reactions was monitored in situ. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. OPC Paste Samples Exposed To Aggressive Solutions. Cementitious Barriers Partnership

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-11-01

    The study presented in this report focused on a low-activity wasteform containing a high-pH pore solution with a significant level of sulfate. The purpose of the study was to improve understanding of the complex concrete/wasteform reactive transport problem, in particular, the role of pH in sulfate attack. Paste samples prepared at three different water-to-cement ratios were tested. The mixtures were prepared with ASTM Type I cement, without additional admixtures. The samples were exposed to two different sodium sulfate contact solutions. The first solution was prepared at 0.15M Na2SO4. The second solution also incorporated 0.5M NaOH, to mimic the high pH conditions found in Saltstone. The data collected indicated that, in Na2SO4 solution, damage occurs to the pastes. In the case of the high-pH sulfate solution (Na2SO4 + NaOH), no signs of damage were observed on any of the paste mixtures. These results indicate that the high sulfate content found in the wasteform pore solution will not necessarily lead to severe damage to concrete. Good-quality mixtures could thus prove durable over the long term, and act as an effective barrier to prevent radionuclides from reaching the environment.

  14. Aqueous solutions/nuclear glasses interactions

    International Nuclear Information System (INIS)

    Delage, F.; Advocat, T.; Vernaz, E.; Crovisier, J.L.

    1991-01-01

    Interactions results of the borosilicate glass used in radioactive wastes confinement and aqueous solutions at various temperature and PH show that for the glass components: - the release rate evolution follows an Arrhenius law, - in acid PH, there is a selective dissolution, - in basic PH, there is a stoechiometric dissolution [fr

  15. Treatment and Conditioning of Radioactive Waste Solution by Natural Clay Minerals

    International Nuclear Information System (INIS)

    El-Dessouky, M.I.; Abdel-Raouf, M.W.; El-Massry, E.H.; Khalifa, S.M.; Aly, H.F.

    1999-01-01

    Chemical precipitation processes have been used for the treatment of radioactive elements from aqueous solution. The volume reduction is not very great and storage facilities are expensive. There are some radionuclides which are so difficult to be precipitated by this common method, so they may be precipitated by adding solid materials such as natural inorganic exchangers. In this woek, improvement the removal of caesium, cobalt and europium with zinc sulfate as coagulant and different clay minerals have been investigated. These include, Feldespare, Aswanly, Bentionite, Hematite, Mud, Calcite, Basalt, Magnetite, Kaoline, Sand stone, Limonite and Sand. The parameters affecting the precipitation process such as pH, particle size, temperature and weight of the clay have been studied. The results indicate that, the highest removal for Cs-137, Co-60 and Eu-152 and154 by Asswanly, Bentonite and Sand stone is more than the other clays. Removal of Cs-137 from low level waste solution with these three natural clays took the sequence, Aswanly (85.5%) > Bentonite (82.2%) > Sandstone (65.4%). Solidified cement products have been evaluated to determine mechanical strength and leaching rates of the waste products. The solidified waste forms were found more acceptable for handling ,storage and ultimate disposal

  16. PH measurement under pressure and at high temperatures; Mesure du pH sous pression et a temperature elevee

    Energy Technology Data Exchange (ETDEWEB)

    Fournie, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Le Peintre, M; Mahieu, C [Centre National de la Recherche Scientifique (CNRS), 91 - Gif-sur-Yvette (France)

    1961-07-01

    In the first part the development and operation of a glass electrode under pressure at room temperature is described. The pressure equilibrium between the inside and outside of the glass membrane several centimetres thick is obtained instantaneously by means of a siphon. The use of a silicone oil as electrical insulator makes possible the working of the glass electrode with the siphon at high pressures (100 kg/cm{sup 2}). In the second part, we determined the pH of various buffer solutions up to 250 deg. C using a cell of our design having two hydrogen electrodes. The values thus obtained for the buffer solutions make it possible to verify and calibrate the pH electrodes independently of the oxido-reduction potential of the medium. In the third part we give the results obtained up to 200 deg. C with the glass electrodes developed in conjunction with the Societe St Gobain. (author) [French] Dans une premiere partie, nous exposons la mise au point et le fonctionnement d'une electrode en verre sous pression a la temperature ordinaire. L'equilibrage instantane de la pression a l'interieur et a l'exterieur de la membrane en verre de quelques diziemes de millimetres d'epaisseur s'effectue par l'intermediaire d'un siphon. L'emploi d'une huile de silicone comme isolant electrique a permis le fonctionnement de l'electrode en verre a siphon sous haute pression (1000 kg/cm{sup 2}). Dans une deuxieme partie, nous avons determine jusqu'a 250 deg. C les valeurs du pH des diverses solutions tampons avec une cellule de notre conception a deux electrodes d'hydrogene. Les valeurs des solutions tampons ainsi obtenues permettent de verifier et d'etalonner les electrodes a pH independantes du potentiel d'oxydo-reduction du milieu. Dans une troisieme partie, nous relatons les resultats obtenus jusqu'a 200 deg. C avec les electrodes en verre mis au point en collaboration avec la Societe Saint-Gobain. (auteur)

  17. Influence of pH on the transport of silver nanoparticles in saturated porous media: laboratory experiments and modeling

    Energy Technology Data Exchange (ETDEWEB)

    Flory, Jason; Kanel, Sushil R., E-mail: sushil.kanel.ctr@afit.edu; Racz, LeeAnn [Air Force Institute of Technology, Department of Systems and Engineering Management (United States); Impellitteri, Christopher A. [U.S. Environmental Protection Agency (United States); Silva, Rendahandi G. [U.S. EPA Test and Evaluation Facility, National Risk Management Research Laboratory, U.S. Environmental Protection Agency, Shaw Environmental and Infrastructure (United States); Goltz, Mark N., E-mail: mark.goltz@afit.edu [Air Force Institute of Technology, Department of Systems and Engineering Management (United States)

    2013-03-15

    Given the ubiquity of silver nanoparticles (AgNPs) and their potential for toxic effects on both humans and the environment, it is important to understand their environmental fate and transport. The purpose of this study is to gain information on the transport properties of commercial AgNP suspensions in a glass bead-packed column under saturated flow conditions at different solution pH levels. Commercial AgNPs were characterized using high-resolution transmission electron microscopy, dynamic light scattering, X-ray photoelectron spectroscopy, ultraviolet visible spectroscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray diffraction. Transport data were collected at different pH levels (4, 6.5, 9, and 11) at fixed ionic strength. Capture of AgNPs increased as the pH of the solution increased from 4 to 6.5. Further increase in pH to 9 and 11 decreased the attachment of AgNPs to the glass beads. AgNP concentration versus time breakthrough data were simulated using an advection-dispersion model incorporating both irreversible and reversible attachment. In particular, a reversible attachment model is required to simulate breakthrough curve tailing at near neutral pH, when attachment is most significant. The laboratory and modeling study reveals that for natural groundwaters, AgNP transport in porous media may be retarded due to capture; but ultimately, most of the mass may be slowly released over time.

  18. Antimicrobial activity and pH of a endodontic sealer containing MTA

    DEFF Research Database (Denmark)

    Maliza, Amanda GA; de Andrade, Flaviana Bombarda; Arias, Marcela C

    Objective: To investigate the antimicrobial activity, calcium release, and pH of a new mineral trioxide aggregate endodontic sealer when compared to endodontic sealers containing calcium hydroxide and/or epoxy resin. Method: Specimens were fabricated from MTA Fillapex, Sealer 26, Sealapex, and AH...... Plus immediately, 24 or 48 hours prior to the tests. The antimicrobial activity against Enterococcus faecalis and Candida albicans was evaluated by the direct contact and the agar diffusion methods. Calcium release was determined by atomic absorption spectrometry. The pH from solutions containing...... in solution with an alkaline pH. Conclusion: The new mineral trioxide aggregate endodontic sealer presented higher antimicrobial activity when compared to the sealers containing calcium hydroxide and/or epoxy resin. As for pH and calcium release, the sealers containing calcium hydroxide resulted in presented...

  19. Lizimetric investigation of vertical transportation of Cs-137 in the different soil types for the different raining conditions: a new solution proposal and application for the Chernobyl accident

    International Nuclear Information System (INIS)

    Varinlioglu, A.

    2000-12-01

    The aim of this Ph.D. thesis is to trace the vertical transportation of water in soil by using the Cs-137 as radiotracer. We have studied 3 different soil types clay, loamy and sandy and 3 different raining conditions. High, normal and low raining regimes that are typical especially for the Black Sea Region were selected for experimental parameters. These experiments have been realized in lizimetric conditions. As a result, the type of applications for the combinations of soil type and raining regime contain experimental originality. Humidity observation technique was also used. The result of the experiments show that in every raining regime the activities of different types of soils can be classified as sand, loam and clay in descending activity order. When the results of the experiments were evaluated according to the raining regime it can be seen that the relative activity for every type of soil is always towards higher to lower raining conditions. These results are what we already have expected and are related to the water permeability of the soil. The surface soil activities have also been measured. The surface soil activities were arranged as clayey, loamy and sandy in descending activity order for every laining regime. The surface soil activities were found to be higher in the soil types in which water could not penetrate deeper. When the relative activity values were compared with the results of the surface soil activities it was recognized that the order of soils changes upside down. This is an evident of harmony for the experimental results. For the evaluation of surface activity it can be seen that the relative activity values for every kind of soil type is always in the same order from the highest to the lowest raining regimes. As a result, it can be said that the all results have significant and have harmonies with each other. Experimental results were comparatively examined by using the s emi infinite convection dispersion model . All the conclusions

  20. Acid-base equilibria in the reaction of tantalum pentafluoride with O,O-diphenyl-H-benzoylamidophosphate (PhO)2P(0)NHC(O)Ph

    International Nuclear Information System (INIS)

    Il'in, E.G.; Kharrmann, Eh.; Shcherbakova, M.N.; Buslaev, Yu.A.

    1987-01-01

    Method of 19 F NMR was used to study TaF 5 interaction with imidodiphosphoric acid ester (PhO) 2 P(O)NHC(O)Ph(LH) in methylene chloride. Dimeric molecular LH(TaF 5 ) 2 complex was the main form in the solution with towfold TaF 5 excess; phosphoryl and carbonyl groups partisipate in complexing at that. Increase of ligand content in the solution up to equimolar one results to preliminary ligand coordination via P=O-group. Introduction of the base excess to the solution results to formation of L - anion which is coordinated to TaF 5 in a monodentate way via phosphoryl group or in a chelate way with fluorine ion substitution and formation of LTaF 4 + cationw

  1. The increase in pH during aging of porous sol-gel silica spheres

    NARCIS (Netherlands)

    Titulaer, M.K.; Kegel, W.K.; Jansen, J.B.H.; Geus, John W.

    1994-01-01

    The increase in pH in the hydrothermal fluid is studied after hydrothermal aging of porous silica gel spheres of 1–3 mm diameter. The porous silica spheres are formed by the sol-gel process from a supersaturated silica solution. The increase of the pH of the hydrothermal solution affects the silica

  2. Resorcinol adsorption from aqueous solution over activated carbon

    International Nuclear Information System (INIS)

    Blanco, Diego A; Giraldo, Liliana; Moreno, Juan C

    2007-01-01

    In this paper, the adsorption behavior of Resorcinol a monohydroxylated phenol, poorly acid to 298 K, over activated carbon is analyzed by studying the solution's pH influence and the surface reduction in the adsorption process. To do this, an activated carbon of lignocellulose origin and a reduced activated carbon was used. The interaction solid solution is characterized by the analyses of adsorption in the isotherms to 298 K and pH values of 7. 00, 9.00 and 11.00 for a period of 48 hours. The capacity adsorption of activated carbons increases when the solution's pH decreases and the retained amount increases in the reduced coal to the pH of maximum adsorption.

  3. Development of a novel pH sensor based upon Janus Green B immobilized on triacetyl cellulose membrane: Experimental design and optimization

    Science.gov (United States)

    Chamkouri, Narges; Niazi, Ali; Zare-Shahabadi, Vali

    2016-03-01

    A novel pH optical sensor was prepared by immobilizing an azo dye called Janus Green B on the triacetylcellulose membrane. Condition of the dye solution used in the immobilization step, including concentration of the dye, pH, and duration were considered and optimized using the Box-Behnken design. The proposed sensor showed good behavior and precision (RSD < 5%) in the pH range of 2.0-10.0. Advantages of this optical sensor include on-line applicability, no leakage, long-term stability (more than 6 months), fast response time (less than 1 min), high selectivity and sensitivity as well as good reversibility and reproducibility.

  4. The potential of curcumin reagent as a natural pH indicator for the development of an optical pH sensor

    International Nuclear Information System (INIS)

    Rosmawani Mohammad; Musa Ahmad; Jamaluddin Mohd Daud

    2007-01-01

    The potential of curcumin reagent as a natural pH indicator for the development of an optical pH sensor was discussed in this study. Curcumin has been chosen because it has never been reported before for use in the development of an optical pH sensor. Curcumin is a coloring constituent of turmeric that giving yellow pigmentation. Curcumin showed clear color changes, for example yellow in acidic and reddish-brown in basic solutions. The color change is fast for example within 5 seconds. Results from the study showed that a linear pH range for this reagent was observed at pH 8-12 (R 2 =0.9854). Curcumin has a good photo stability with RSD value of 1.42 % for a study period of 6 months. The RSD values of the reproducibility study were found to be 1.43 % and 0.37 % for pH 9 and pH 12, respectively. Characterisation of the immobilised curcumin reagent also showed promising results, hence a good potential for use as a sensing reagent for an optical pH sensor. (author)

  5. Effect of pH on cadmium biosorption by coconut copra meal

    International Nuclear Information System (INIS)

    Ofomaja, Augustine E.; Ho, Y.-S.

    2007-01-01

    Biosorption of cadmium ion by coconut copra meal, an agricultural waste product was investigated as a function of initial solution pH and initial cadmium concentration. Pseudo-second-order kinetic analyses were performed to determine the rate constant of biosorption, the equilibrium capacity, and initial biosorption rate. Cadmium biosorption by copra meal was found to be dependent on the initial solution pH and initial cadmium concentration. Ion exchange occurred in the initial biosorption period. In addition, mathematical relationships were drawn to relate the change in the solution hydrogen ion concentration with equilibrium biosorption capacity, initial cadmium concentration, and equilibrium biosorption capacity

  6. Modulating β-lactoglobulin nanofibril self-assembly at pH 2 using glycerol and sorbitol.

    Science.gov (United States)

    Dave, Anant C; Loveday, Simon M; Anema, Skelte G; Jameson, Geoffrey B; Singh, Harjinder

    2014-01-13

    β-Lactoglobulin (β-lg) forms fibrils when heated at 80 °C, pH 2, and low ionic strength (sorbitol (0-50% w/v) on β-lg self-assembly at pH 2. Glycerol and sorbitol stabilize native protein structure and modulate protein functionality by preferential exclusion. In our study, both polyols decreased the rate of β-lg self-assembly but had no effect on the morphology of fibrils. The mechanism of these effects was studied using circular dichroism spectroscopy and SDS-PAGE. Sorbitol inhibited self-assembly by stabilizing β-lg against unfolding and hydrolysis, resulting in fewer fibrillogenic species, whereas glycerol inhibited nucleation without inhibiting hydrolysis. Both polyols increased the viscosity of the solutions, but viscosity appeared to have little effect on fibril assembly, and we believe that self-assembly was not diffusion-limited under these conditions. This is in agreement with previous reports for other proteins assembling under different conditions. The phenomenon of peptide self-assembly can be decoupled from protein hydrolysis using glycerol.

  7. A cow-level association of ruminal pH on body condition score, serum beta-hydroxybutyrate and postpartum disorders in Thai dairy cattle.

    Science.gov (United States)

    Chaidate, Inchaisri; Somchai, Chanpongsang; Jos, Noordhuizen; Henk, Hogeveen

    2014-09-01

    Subacute ruminal acidosis in dairy cows occurs when ruminal pH is below about 5.5. However, the exact threshold level of ruminal pH affecting cow health is still in debate. This investigation was carried out in 505 cows within 31 farms. The postpartum disorders, including dystocia, retained placenta, anestrus, cystic ovary, metritis, clinical mastitis and lameness, were analyzed. Ruminal pH, serum beta-hydroxy butyrate (SBHB), serum urea nitrogen and body condition score (BCS) were measured once during the 3 to 6 weeks postpartum, while BCS was determined once more at 1 week before calving. Ruminal pH was determined by ruminocentesis technique. The ruminal pH was evaluated to study the association with BCS, SBHB and postpartum disorders using linear regression in a generalized linear mixed model with farm as a random effect. The results show that low ruminal pH was associated with dystocia, metritis and lameness. Moreover, a low ruminal pH can be found in cows with a high loss of BCS after calving and also in cows with low SBHB postpartum. These findings confirmed the feasibility of the ruminocentesis technique and the association of low ruminal pH on various postpartum disorders at the individual cow level. However, the consequences of low ruminal pH on dairy cow health still needs more exploration for a better understanding of the physiological mechanisms. © 2014 Japanese Society of Animal Science.

  8. Study of the pitting and repassiv,tion corrosion potential of zicaloy-4 halides solutions at 250C and several pH

    International Nuclear Information System (INIS)

    Gardiazabal, J.I.; Cordova, R.; Gomez, H.; Layana, G.; Schrebler, R.

    1987-01-01

    The electrochemical behaviour of Zircaloy-4 electrode in chloride, bromide and iodide acid solution was investigated at 25 0 C employing stationary, quasi-stationary and potentiodynamic techniques. The results show that the pitting and repassivation potentials are independent on pH but both are dependent on halice concentration, following linear relation ships in these cases. It is also possible to correlate the pitting potential with the ionic radius of the anions, allowing thus to establish an order in their agressive properties. This order was extrapolated for fluoride ion and further experimental measurements show that the corrosion potential of Zircaloy-4 in acid or neutra solution of this ion (which undergoes active dissolution) is coincident with that predicted from the Ep v/s ionic radius determined for the other halides. (Author) [pt

  9. Preconditioned characteristic boundary conditions based on artificial compressibility method for solution of incompressible flows

    Science.gov (United States)

    Hejranfar, Kazem; Parseh, Kaveh

    2017-09-01

    The preconditioned characteristic boundary conditions based on the artificial compressibility (AC) method are implemented at artificial boundaries for the solution of two- and three-dimensional incompressible viscous flows in the generalized curvilinear coordinates. The compatibility equations and the corresponding characteristic variables (or the Riemann invariants) are mathematically derived and then applied as suitable boundary conditions in a high-order accurate incompressible flow solver. The spatial discretization of the resulting system of equations is carried out by the fourth-order compact finite-difference (FD) scheme. In the preconditioning applied here, the value of AC parameter in the flow field and also at the far-field boundary is automatically calculated based on the local flow conditions to enhance the robustness and performance of the solution algorithm. The code is fully parallelized using the Concurrency Runtime standard and Parallel Patterns Library (PPL) and its performance on a multi-core CPU is analyzed. The incompressible viscous flows around a 2-D circular cylinder, a 2-D NACA0012 airfoil and also a 3-D wavy cylinder are simulated and the accuracy and performance of the preconditioned characteristic boundary conditions applied at the far-field boundaries are evaluated in comparison to the simplified boundary conditions and the non-preconditioned characteristic boundary conditions. It is indicated that the preconditioned characteristic boundary conditions considerably improve the convergence rate of the solution of incompressible flows compared to the other boundary conditions and the computational costs are significantly decreased.

  10. Low pH Cements

    International Nuclear Information System (INIS)

    Savage, David; Benbow, Steven

    2007-05-01

    speciation of silicon at pH 10 has a significant impact upon the solubility of montmorillonite and would thus constitute a logical choice of pH limit for cement-derived pore fluids, but it is unlikely that cement-based grouts could be developed to meet this limit. Control of mass transport by diffusion processes serves as a significant constraint over the amount of bentonite that can be degraded. Computer simulations indicate that porosity reduction is likely at the interface between cement and bentonite. However, it is not clear how the transport properties of bentonite may be modified due to mineral alteration processes. There are considerable uncertainties concerning the precise mechanism of the rate of montmorillonite dissolution at elevated pH. The rate of dissolution may be inhibited by the presence of dissolved Si (and perhaps Al), but this mechanism has yet to be confirmed at high pH. The type of secondary minerals assumed to form from cement-bentonite interaction will also have a significant impact upon the rate of montmorillonite dissolution. Low-pH cement systems have received little attention thus far regarding the development of models for the chemical evolution of pore fluids. Low Ca/Si CSH gels show preferential leaching of Si, which is in marked contrast with gels of greater Ca/Si ratio. Models apparently capable of predicting pore fluid composition coexisting with low Ca/Si CSH gels are a modified Berner model and a solid-solution model proposed by Sugiyama and Fujita. The solubility of silica in pore fluids coexisting with low Ca/Si gels may exceed that of amorphous silica, and may pose problems regarding the stability of montmorillonite in relation to framework silicates such as feldspars. However, the potential rate of conversion of montmorillonite to feldspar under repository conditions is uncertain. It is necessary to use additives such as super plasticiser to improve the workability of low-pH cements. These organic additives have the potential to

  11. Low pH Cements

    Energy Technology Data Exchange (ETDEWEB)

    Savage, David; Benbow, Steven [Quintessa Ltd., Henley-on-Thames (United Kingdom)

    2007-05-15

    speciation of silicon at pH 10 has a significant impact upon the solubility of montmorillonite and would thus constitute a logical choice of pH limit for cement-derived pore fluids, but it is unlikely that cement-based grouts could be developed to meet this limit. Control of mass transport by diffusion processes serves as a significant constraint over the amount of bentonite that can be degraded. Computer simulations indicate that porosity reduction is likely at the interface between cement and bentonite. However, it is not clear how the transport properties of bentonite may be modified due to mineral alteration processes. There are considerable uncertainties concerning the precise mechanism of the rate of montmorillonite dissolution at elevated pH. The rate of dissolution may be inhibited by the presence of dissolved Si (and perhaps Al), but this mechanism has yet to be confirmed at high pH. The type of secondary minerals assumed to form from cement-bentonite interaction will also have a significant impact upon the rate of montmorillonite dissolution. Low-pH cement systems have received little attention thus far regarding the development of models for the chemical evolution of pore fluids. Low Ca/Si CSH gels show preferential leaching of Si, which is in marked contrast with gels of greater Ca/Si ratio. Models apparently capable of predicting pore fluid composition coexisting with low Ca/Si CSH gels are a modified Berner model and a solid-solution model proposed by Sugiyama and Fujita. The solubility of silica in pore fluids coexisting with low Ca/Si gels may exceed that of amorphous silica, and may pose problems regarding the stability of montmorillonite in relation to framework silicates such as feldspars. However, the potential rate of conversion of montmorillonite to feldspar under repository conditions is uncertain. It is necessary to use additives such as super plasticiser to improve the workability of low-pH cements. These organic additives have the potential to

  12. Soil solution interactions may limit Pb remediation using P amendments in an urban soil.

    Science.gov (United States)

    Obrycki, John F; Scheckel, Kirk G; Basta, Nicholas T

    2017-01-01

    Lead (Pb) contaminated soils are a potential exposure hazard to the public. Amending soils with phosphorus (P) may reduce Pb soil hazards. Soil from Cleveland, OH containing 726 ± 14 mg Pb kg -1 was amended in a laboratory study with bone meal and triple super phosphate (TSP) at 5:1 P:Pb molar ratios. Soil was acidified, neturalized and re-acidified to encourage Pb phosphate formation. PRSTM-probes were used to evaluate changes in soil solution chemistry. Soil acidification did not decrease in vitro bioaccessible (IVBA) Pb using either a pH 1.5, 0.4 M glycine solution or a pH 2.5 solution with organic acids. PRSTM-probe data found soluble Pb increased 10-fold in acidic conditions compared to circumnetural pH conditions. In acidic conditions (p = 3-4), TSP treated soils increased detected P 10-fold over untreated soils. Bone meal application did not increase PRSTM-probe detected P, indicating there may have been insufficient P to react with Pb. X-ray absorption spectroscopy suggested a 10% increase in pyromorphite formation for the TSP treated soil only. Treatments increased soil electrical conductivity above 16 mS cm -1 , potentially causing a new salinity hazard. This study used a novel approach by combining the human ingestion endpoint, PRSTM-probes, and X-ray absorption spectroscopy to evaluate treatment efficacy. PRSTM-probe data indicated potentially excess Ca relative to P across incubation steps that could have competed with Pb for soluble P. More research is needed to characterize soil solutions in Pb contaminated urban soils to identify where P treatments might be effective and when competing cations, such as Ca, Fe, and Zn may limit low rate P applications for treating Pb soils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. The exact solution to the one-dimensional Poisson–Boltzmann equation with asymmetric boundary conditions

    DEFF Research Database (Denmark)

    Johannessen, Kim

    2014-01-01

    The exact solution to the one-dimensional Poisson–Boltzmann equation with asymmetric boundary conditions can be expressed in terms of the Jacobi elliptic functions. The boundary conditions determine the modulus of the Jacobi elliptic functions. The boundary conditions can not be solved analytically...

  14. Dependence of precipitation of trace elements on pH in standard water

    Science.gov (United States)

    Verma, Shivcharan; Mohanty, Biraja P.; Singh, K. P.; Behera, B. R.; Kumar, Ashok

    2018-04-01

    The present work aimed to study the dependence of precipitation of trace elements on the pH of solution. A standard solution was prepared by using ultrapure deionized water (18.2 MΩ/cm) as the solvent and 11 water-soluble salts having different elements as solutes. Five samples of different pH values (2 acidic, 2 basic, and 1 neutral) were prepared from this standard solution. Sodium-diethyldithiocarbamate was used as the chelating agent to precipitate the metal ions present in these samples of different pH values. The targets were prepared by collecting these precipitates on mixed cellulose esters filter of 0.4 μm pore size by vacuum filtration. Elemental analysis of these targets was performed by particle-induced X-ray emission (PIXE) using 2.7 MeV protons from the single Dee variable energy cyclotron at Panjab University, Chandigarh, India. PIXE data were analyzed using GUPIXWIN software. For most of the elements, except Hg with oxidation state +2, such as Co, Ni, Zn, Ba, and Cd, a general trend of enhancement in precipitation was observed with the increase in pH. However, for other elements such as V, As, Mo, Ag, and Bi, which have oxidation state other than +2, no definite pattern was observed. Precipitation of Ba and As using this method was negligible at all five pH values. From these results, it can be concluded that the precipitation and recovery of elements depend strongly on the pH of the water sample.

  15. The role of Eh and pH in leaching Saskatchewan uranium ores with chloride and nitrate leaching systems

    International Nuclear Information System (INIS)

    Nirdosh, I.; Muthuswami, S.V.

    1992-01-01

    The effects of solution E h and pH on the extractions of U, 230 Th, 226 Ra, As and Ni from two typical uranium ores from the province of Saskatchewan in Canada are discussed for the leachants ferric chloride, ferric nitrate, nitric acid and hydrochloric acid. It is concluded that E h > 700 mV and pH 230 Th extraction is more sensitive to solution pH than to E h whereas Ni extraction is sensitive mainly to the solution E h . Arsenic extraction is very sensitive to solution E h , and for a given E h , is high at pH 1.3. (orig.) [de

  16. Influence of pH on the adsorption of uranium ions by oxidized activated carbon and chitosan

    International Nuclear Information System (INIS)

    Park, G.I.; Park, H.S.; Woo, S.I.

    1999-01-01

    The adsorption characteristics of uranyl ions on surface-oxidized carbon were compared with those of powdered chitosan over a wide pH range. In particular, an extensive analysis was made on solution pH variation during the adsorption process or after adsorption equilibrium. Uranium adsorption on the two adsorbents was revealed to be strongly dependent on the initial pH of the solution. A quantitative comparison of the adsorption capacities of the two adsorbents was made, based on the isotherm data obtained at initial pH 3, 4, and 5. In order to analyze the adsorption kinetics incorporated with pH effects, batch experiments at various initial pH values were carried out, and solution pH profiles with the adsorption time were also evaluated. The breakthrough behavior in a column packed with oxidized carbon was also characterized with respect to the variation of effluent pH. Based on these experimental results, the practical applicability of oxidized carbon for uranium removal from acidic radioactive liquid waste was suggested

  17. Influence of sulphate-reducing bacteria on environmental parameters and marine corrosion behavior of Q235 steel in aerobic conditions

    International Nuclear Information System (INIS)

    Wan Yi; Zhang Dun; Liu Huaiqun; Li Yongjuan; Hou Baorong

    2010-01-01

    The growth cycle of sulphate-reducing bacteria (SRB), Desulfovibrio caledoniensis, and the effect of SRB on the environmental parameters and corrosion behavior of Q235 steel during a growth cycle in aerobic (air- and O 2 -saturated culture solutions) and anaerobic (N 2 - saturated culture solutions) conditions were investigated. Oxygen dissolved in the culture solutions induced slow growth and fast decay of SRB. The growth process of SRB under anaerobic and aerobic conditions influenced sulphide anion concentration (C s 2- ), pH, and conductivity (κ). The values of C s 2- and κ under aerobic conditions were lower than those under anaerobic conditions, and the pH values increased from O 2 - to air- to N 2 -saturated culture solutions. Aerobic conditions induced the open circuit potential (E OC ) to shift in the positive direction after the stationary phase of SRB growth. The charge transfer resistance (R ct ) increased quickly during the exponential growth phase, almost maintained stability during the stationary phase, and decreased after the stationary phase in all three conditions, and the impedance magnitude decreased from O 2 - to air- to N 2 -saturated culture solutions. The biofilms induced by SRB were observed by scanning electron microscopy (SEM) under aerobic and anaerobic conditions, and energy dispersive spectroscopy (EDS) was performed in abiotic and SRB-containing systems to distinguish the corrosion products. The reasons for the effects of SRB on the environmental parameters and corrosion behavior of carbon steel are discussed.

  18. Dissolution kinetics of heulandite at pH 2--12 and 25 degrees C

    International Nuclear Information System (INIS)

    Ragnarsdottir, K.V.

    1993-01-01

    Because of their favourable cation exchange reactions, heulandite and clinoptilolite have been suggested as being capable of immobilizing radionuclides and therefore could possibly act as an important barrier for nuclear waste. Recent studies of laboratory-reacted minerals indicate, however, that hydrated surface layers tend to accumulate highly hydrolyzable heavy elements. These hydrated layers may therefore be the most important retardants for radionuclides. The dissolution rate of heulandite depends strongly on pH. Based on silica release, the logarithm of the steady-state dissolution rate at pH 2 is -13.1 mol cm -2 s -1 . The logarithm of the rate decreases to -15.8 mol cm -2 s -1 at pH 7.2 and increases again to -14.6 mol cm -2 s -1 at pH 12.2. At low pH, Al is released preferentially to silica; but at intermediate and high pH, the release of silica appears to be congruent relative to Al. The change in dissolution rate with pH indicates that at low pH, the dissolution mechanism is controlled by the detachment of a positively charged Al species, >Al-OH 2 + . Below pH 5, however, a silica-rich surface layer is formed requiring diffusion through the layer. At intermediate and high pH, it is likely that the dissolution rate is controlled by the detachment of a negatively charged silica species, >Si - O - . The reaction order of the hydrogen ion under low pH conditions is 0.7, and the reaction order of the OH - ion is 0.3 at high pH. The measured dissolution rates indicate that a 1 mm heulandite crystal would dissolve in 300,000 yrs if the solution composition is maintained undersaturated. 75 refs., 11 figs., 3 tabs

  19. The pH behavior of a 2-aminoethyl dihydrogen phosphate zwitterion studied with NMR-titrations

    Science.gov (United States)

    Myller, A. T.; Karhe, J. J.; Haukka, M.; Pakkanen, T. T.

    2013-02-01

    In this study a bifunctional 2-aminoethyl dihydrogen phosphate (AEPH2) was 1H and 31P NMR characterized in a pH range of 1-12 in order to determine the zwitterion properties in different pH regions in H2O and D2O solutions. NMR was also used to determine the pH range where AEPH2 exists as a zwitterion. The phosphate group has two deprotonation points, around pH 1 and 6, while the amino group deprotonates at pH 11. The zwitterion form of AEPH2 (NH3+sbnd CHsbnd CHsbnd OPOH) exists as the main ion between pH 1 and 6 in water solutions and also in the solid state.

  20. Analytical solutions of couple stress fluid flows with slip boundary conditions

    Directory of Open Access Journals (Sweden)

    Devakar M.

    2014-09-01

    Full Text Available In the present article, the exact solutions for fundamental flows namely Couette, Poiseuille and generalized Couette flows of an incompressible couple stress fluid between parallel plates are obtained using slip boundary conditions. The effect of various parameters on velocity for each problem is discussed. It is found that, for each of the problems, the solution in the limiting case as couple stresses approaches to zero is similar to that of classical viscous Newtonian fluid. The results indicate that, the presence of couple stresses decreases the velocity of the fluid.

  1. Effect of pH on the structural, optical and morphological properties of Ga-doped ZnO nanoparticles by reflux precipitation method

    Science.gov (United States)

    Ungula, J.; Dejene, B. F.; Swart, H. C.

    2018-04-01

    Gallium-doped zinc oxide nanoparticles (GZO NPs) were synthesized by the reflux precipitation method at 1, 3, 5, 7 and 8 pH conditions of Ga/Zn precursor solution (Ga/Zn sol.). Analysis of X-ray diffraction (XRD) spectra showed that the diffraction peak intensities of GZO NPs increased and the crystallite sizes varied from 11 to 27 nm with an increase in the pH of the Zn/Ga sol. Scanning electron microscopy micrographs showed agglomerated tiny particles that formed on big slabs of nanorods at the lower pH, but fine and enlarged particles on nano-spherical bases formed at the higher pH values. The photoluminescence exciton peak intensities of the GZO NPs and their respective FWHM increased to a maximum at the 5 pH and then reduced slightly as the solution got more basic. The increase of the deep level peak intensities with the increase in the pH followed the XRD diffraction intensity results. It was observed that both the exciton and DLE peaks emission positions shifted to lower wavelengths up to the 5 pH and then red shifted for a further increase in the pH values. The UV-vis analysis also demonstrated that the optical properties of the GZO NPs improved with the increase Ga/Zn sol. pH, as shown by the blue shift of the absorption edge of the reflectance spectra. The band gap energy was tuned from 3.18 to 3.31 eV with the increase in the pH from 1 to 5. An additional increase in the pH yielded no significant change in the optical properties of the GZO NPs.

  2. Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface

    Science.gov (United States)

    Shahrestani, S.; Ismail, M. C.; Kakooei, S.; Beheshti, M.; Zabihiazadboni, M.; Zavareh, M. A.

    2018-03-01

    A simple technique to fabricate the iridium oxide pH sensor is useful in several applications such as medical, food processing and engineering material where it is able to detect the changes of pH. Generally, the fabrication technique can be classified into three types: electro-deposition iridium oxide film (EIrOF), activated iridium oxide film (AIROF) and sputtering iridium oxide film (SIROF). This study focuses on fabricating electrode, calibration and test. Electro-deposition iridium oxide film is a simple and effective method of fabricating this kind of sensor via cyclic voltammetry process. The iridium oxide thick film was successfully electrodeposited on the surface of stainless steel wire with 500 cycles of sweep potential. A further analysis under FESEM shows detailed image of iridium oxide film which has cauliflower-liked microstructure. EDX analysis shows the highest element present are iridium and oxygen which concluded that the process is successful. The iridium oxide based pH sensor has shown a good performance in comparison to conventional glass pH sensor when it is being calibrated in buffer solutions with 2, 4, 7 and 9 pH values. The iridium oxide pH sensor is specifically designed to measure the pH on the surface of metal plate.

  3. [pH sensors based on rubbery ormosils preparation and their spectrum studies].

    Science.gov (United States)

    Chen, Xi; Dai, Yuan-jing; Li, Wei; Zhuang, Zhi-xia; Wang, Xiao-ru

    2002-02-01

    A new type of methyl substituted ormosils as a matrix for bromophenol blue (BPhB) and bromocresol green (BCG) is described. The new ormosils combine features of classical TEOS sol-gel material such as solvability in organic solvent and those of sol-gel glasses such as transparent and a porous structure, the ormosils also make a good mechanical stability. The influence of the conditions during the polymerisation process on the photochemical properties of BPhB and BCG has been studied. This sol-gel material was wed to immobilize pH-sensitive absorption dyes, bromothymol blue and bromocresol green, to prepare pH sensing films. The several aspects of the sensing films, including the leaching of the dye from gel, response time to different pH buffer solution, absorption spectra and the improvement of the immobilization of the dyes to filmo, were also discussed.

  4. Shelf-Life of Chlorine Solutions Recommended in Ebola Virus Disease Response.

    Science.gov (United States)

    Iqbal, Qais; Lubeck-Schricker, Maya; Wells, Emma; Wolfe, Marlene K; Lantagne, Daniele

    2016-01-01

    In Ebola Virus Disease (EVD) outbreaks, it is widely recommended to wash living things (handwashing) with 0.05% (500 mg/L) chlorine solution and non-living things (surfaces, personal protective equipment, dead bodies) with 0.5% (5,000 mg/L) chlorine solution. Chlorine solutions used in EVD response are primarily made from powdered calcium hypochlorite (HTH), granular sodium dichloroisocyanurate (NaDCC), and liquid sodium hypochlorite (NaOCl), and have a pH range of 5-11. Chlorine solutions degrade following a reaction highly dependent on, and unusually sensitive to, pH, temperature, and concentration. We determined the shelf-life of 0.05% and 0.5% chlorine solutions used in EVD response, including HTH, NaDCC, stabilized NaOCl, generated NaOCl, and neutralized NaOCl solutions. Solutions were stored for 30 days at 25, 30, and 35°C, and tested daily for chlorine concentration and pH. Maximum shelf-life was defined as days until initial concentration fell to pH = 7) had a maximum shelf-life of a few hours, NaDCC solutions (pH = 6) 2 days, generated NaOCl solutions (pH = 9) 6 days, and HTH and stabilized NaOCl solutions (pH 9-11) >30 days. Models were developed for solutions with maximum shelf-lives between 1-30 days. Extrapolating to 40°C, the maximum predicted shelf-life for 0.05% and 0.5% NaDCC solutions were 0.38 and 0.82 hours, respectively; predicted shelf-life for 0.05% and 0.5% generated NaOCl solutions were >30 and 5.4 days, respectively. Each chlorine solution type offers advantages and disadvantages to responders, as: NaDCC is an easy-to-import high-concentration effervescent powder; HTH is similar, but forms a precipitate that may clog pipes; and, NaOCl solutions can be made locally, but are difficult to transport. We recommend responders chose the most appropriate source chlorine compound for their use, and ensure solutions are stored at appropriate temperatures and used or replaced before expiring.

  5. Physicochemistry of the plasma-electrolyte solution interface

    International Nuclear Information System (INIS)

    Chen Qiang; Saito, Kenji; Takemura, Yu-ichiro; Shirai, Hajime

    2008-01-01

    The atmospheric rf plasma discharge was successfully investigated using NaOH or HCl electrolyte solutions as a counter electrode at different pH values. The emission intensities of solution components, self bias, and electron density strongly depend on the pH value of electrolyte. An addition of ethanol to the electrolyte solutions enhanced the dehydration, which markedly promoted the emissions of solution components as well as electrons from the solution. An acidification of the solution was always observed after the plasma exposure and two coexisting mechanisms were proposed to give a reasonable interpretation. The plasma-electrolyte interface was discussed based on a model of hydrogen cycle

  6. Influences of salt concentration, loading and pH on strontium adsorption

    International Nuclear Information System (INIS)

    Atun, G.; Kaplan, Z.

    1996-01-01

    The adsorption of Sr on clay with contains zeolites and montmorillonite mixtures was investigated in solutions of NaCl by means of a batch technique. Sr retention was reduced with increasing NaCl concentration from 5*10 -4 to 5*10 -1 M. Distribution coefficients (K d ) linearly increased with pH in the acidic region but they were almost independent of pH in neutral and alkaline solutions. By fitting the data of the Dubinin-Radushkevich (D-R) isotherm, the mean energies of adsorption and adsorption capacities of Sr at different pH values were calculated. The results showed that the mode of adsorption below pH 4.5 is ion exchange, while above that value a multilayer adsorption occurs. Adsorption data were fitted to the Freundlich isotherm and from empirical Freundlich parameters a site distribution function was calculated. (author)

  7. Iodine volatilization from irradiated CsI solutions

    Energy Technology Data Exchange (ETDEWEB)

    Evans, G J; Panyan, E J [Toronto Univ., ON (Canada). Dept. of Chemical Engineering and Applied Chemistry

    1996-12-01

    A bench-scale, separate-effect, flow apparatus has been constructed to examine volatile iodine production rates in relation to a selection of the possible variables and conditions found in a containment structure with a breached reactor core. The constructed apparatus is designed to provide the widest possible range of data including gas and aqueous phase speciation for an established set of interfacial mass transfer parameters with known pH and dissolved oxygen levels. As the interfacial transfer of iodine is an important component in the understanding of iodine chemistry, commissioning of the constructed apparatus focused on establishing a well characterized set of mass transfer parameters for a variety of mixing conditions and solution volumes. Aqueous phase parameters, obtained using a method involving the sparging of the dissolved oxygen in the aqueous phase, were found to vary by one order of magnitude, from 1x10{sup -2} to 1x10{sup -3} dm/sec. Gas phase parameters also changeable by one order of magnitude, from 1x10{sup -1} to 1x10{sup -2} dm/sec, were studied more thoroughly as they were found to have a greater impact in the system. Two independent methods of analysis were used, one involving tri-iodide solutions, the other using relative humidity values. A selection of the acquired volatility rates in relation to the effect of pH are presented. The apparatus has been found to consistently provide rates up to one order of magnitude lower than modelled predictions. Specifically, for buffered solutions, rates of 2x10{sup -12} mol/min and 1x10{sup -10} mol/min for pH 9 and 5 respectively, have been found. Rates of 1x10{sup -11} mol/min and 6x10{sup -10} mol/min are predicted. Current efforts have addressed potential reasons for this apparent discrepancy, the major factor being the possible release of components from the stainless steel during irradiation. Efforts undertaken to ensure the validity of the results are emphasized. (Abstract Truncated)

  8. Open-gated pH sensor fabricated on an undoped-AlGaN/GaN HEMT structure.

    Science.gov (United States)

    Abidin, Mastura Shafinaz Zainal; Hashim, Abdul Manaf; Sharifabad, Maneea Eizadi; Rahman, Shaharin Fadzli Abd; Sadoh, Taizoh

    2011-01-01

    The sensing responses in aqueous solution of an open-gated pH sensor fabricated on an AlGaN/GaN high-electron-mobility-transistor (HEMT) structure are investigated. Under air-exposed ambient conditions, the open-gated undoped AlGaN/GaN HEMT only shows the presence of a linear current region. This seems to show that very low Fermi level pinning by surface states exists in the undoped AlGaN/GaN sample. In aqueous solution, typical current-voltage (I-V) characteristics with reasonably good gate controllability are observed, showing that the potential of the AlGaN surface at the open-gated area is effectively controlled via aqueous solution by the Ag/AgCl gate electrode. The open-gated undoped AlGaN/GaN HEMT structure is capable of distinguishing pH level in aqueous electrolytes and exhibits linear sensitivity, where high sensitivity of 1.9 mA/pH or 3.88 mA/mm/pH at drain-source voltage, V(DS) = 5 V is obtained. Due to the large leakage current where it increases with the negative gate voltage, Nernstian like sensitivity cannot be determined as commonly reported in the literature. This large leakage current may be caused by the technical factors rather than any characteristics of the devices. Surprisingly, although there are some imperfections in the device preparation and measurement, the fabricated devices work very well in distinguishing the pH levels. Suppression of current leakage by improving the device preparation is likely needed to improve the device performance. The fabricated device is expected to be suitable for pH sensing applications.

  9. Open-Gated pH Sensor Fabricated on an Undoped-AlGaN/GaN HEMT Structure

    Directory of Open Access Journals (Sweden)

    Taizoh Sadoh

    2011-03-01

    Full Text Available The sensing responses in aqueous solution of an open-gated pH sensor fabricated on an AlGaN/GaN high-electron-mobility-transistor (HEMT structure are investigated. Under air-exposed ambient conditions, the open-gated undoped AlGaN/GaN HEMT only shows the presence of a linear current region. This seems to show that very low Fermi level pinning by surface states exists in the undoped AlGaN/GaN sample. In aqueous solution, typical current-voltage (I-V characteristics with reasonably good gate controllability are observed, showing that the potential of the AlGaN surface at the open-gated area is effectively controlled via aqueous solution by the Ag/AgCl gate electrode. The open-gated undoped AlGaN/GaN HEMT structure is capable of distinguishing pH level in aqueous electrolytes and exhibits linear sensitivity, where high sensitivity of 1.9 mA/pH or 3.88 mA/mm/pH at drain-source voltage, VDS = 5 V is obtained. Due to the large leakage current where it increases with the negative gate voltage, Nernstian like sensitivity cannot be determined as commonly reported in the literature. This large leakage current may be caused by the technical factors rather than any characteristics of the devices. Surprisingly, although there are some imperfections in the device preparation and measurement, the fabricated devices work very well in distinguishing the pH levels. Suppression of current leakage by improving the device preparation is likely needed to improve the device performance. The fabricated device is expected to be suitable for pH sensing applications.

  10. Alkaline pH activates the transport activity of GLUT1 in L929 fibroblast cells.

    Science.gov (United States)

    Gunnink, Stephen M; Kerk, Samuel A; Kuiper, Benjamin D; Alabi, Ola D; Kuipers, David P; Praamsma, Riemer C; Wrobel, Kathryn E; Louters, Larry L

    2014-04-01

    The widely expressed mammalian glucose transporter, GLUT1, can be acutely activated in L929 fibroblast cells by a variety of conditions, including glucose deprivation, or treatment with various respiration inhibitors. Known thiol reactive compounds including phenylarsine oxide and nitroxyl are the fastest acting stimulators of glucose uptake, implicating cysteine biochemistry as critical to the acute activation of GLUT1. In this study, we report that in L929 cells glucose uptake increases 6-fold as the pH of the uptake solution is increased from 6 to 9 with the half-maximal activation at pH 7.5; consistent with the pKa of cysteine residues. This pH effect is essentially blocked by the pretreatment of the cells with either iodoacetamide or cinnamaldehyde, compounds that form covalent adducts with reduced cysteine residues. In addition, the activation by alkaline pH is not additive at pH 8 with known thiol reactive activators such as phenylarsine oxide or hydroxylamine. Kinetic analysis in L929 cells at pH 7 and 8 indicate that alkaline conditions both increases the Vmax and decreases the Km of transport. This is consistent with the observation that pH activation is additive to methylene blue, which activates uptake by increasing the Vmax, as well as to berberine, which activates uptake by decreasing the Km. This suggests that cysteine biochemistry is utilized in both methylene blue and berberine activation of glucose uptake. In contrast a pH increase from 7 to 8 in HCLE cells does not further activate glucose uptake. HCLE cells have a 25-fold higher basal glucose uptake rate than L929 cells and the lack of a pH effect suggests that the cysteine biochemistry has already occurred in HCLE cells. The data are consistent with pH having a complex mechanism of action, but one likely mediated by cysteine biochemistry. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Effect of pH and H2O2 dosage on catechol oxidation in nano-Fe3O4 catalyzing UV-Fenton and identification of reactive oxygen species

    DEFF Research Database (Denmark)

    Li, Weiguang; Wang, Yong; Angelidaki, Irini

    2014-01-01

    and then increased, which was ascribed to the formation and destruction of some carboxylic acids. During the degradation, formic acid, acetic acid, oxalic acid, and maleic acid were detected. The values of H2O2 utilization efficiency at 240min near 1.30 in reactions with 11.80mM H2O2 under initial pH from 5.0 to 8.......0-8.0), this heterogeneous UV-Fenton process was powerful, especially reaction at pH 7.0 obtaining the highest COD removal of 93%. The remarkably high oxidation efficiency under neutral and slightly basic conditions was due to fast decrease of solution pH to be strongly acidic. Solution pH decreased until 120min...

  12. Fluoride release from fluoride varnishes under acidic conditions.

    Science.gov (United States)

    Lippert, F

    2014-01-01

    The aim was to investigate the in vitro fluoride release from fluoride varnishes under acidic conditions. Poly(methyl methacrylate) blocks (Perspex, n=3 per group) were painted with 80 ± 5 mg fluoride varnish (n=10) and placed into artificial saliva for 30 min. Then, blocks were placed into either 1% citric acid (pH 2.27) or 0.3% citric acid (pH 3.75) solutions (n=3 per solution and varnish) for 30 min with the solutions being replaced every 5 min. Saliva and acid solutions were analyzed for fluoride content. Data were analyzed using three-way ANOVA (varnish, solution, time). The three-way interaction was significant (p>0.0001). Fluoride release and release patterns varied considerably between varnishes. Fluoride release in saliva varied by a factor of more than 10 between varnishes. Some varnishes (CavityShield, Nupro, ProFluorid, Vanish) showed higher fluoride release in saliva than during the first 5 min of acid exposure, whereas other varnishes (Acclean, Enamel-Pro, MI Varnish, Vella) showed the opposite behavior. There was little difference between acidic solutions. Fluoride release from fluoride varnishes varies considerably and also depends on the dissolution medium. Bearing in mind the limitations of laboratory research, the consumption of acidic drinks after fluoride varnish application should be avoided to optimize the benefit/risk ratio.

  13. Recovery of cyanide in gold leach waste solution by volatilization and absorption.

    Science.gov (United States)

    Gönen, N; Kabasakal, O S; Ozdil, G

    2004-09-10

    In this study, the effects of pH, time and temperature in regeneration of cyanide in the leaching waste solution of gold production from disseminated gold ore by cyanidation process were investigated and the optimum conditions, consumptions and cyanide recovery values were determined. The sample of waste solution containing 156 mg/l free CN- and 358 mg/l total CN-, that was obtained from Gümüşhane-Mastra/Turkey disseminated gold ores by cyanidation and carbon-in-pulp (CIP) process under laboratory conditions was used in the experiments. Acidification with H2SO4, volatilization of hydrogen cyanide (HCN) with air stripping and absorption of HCN in a basic solution stages were applied and under optimum conditions, 100% of free cyanide and 48% of complex cyanide and consequently 70% of the total cyanide in the liquid phase of gold leach effluent are recovered.

  14. Relationship among Phosphorus Circulation Activity, Bacterial Biomass, pH, and Mineral Concentration in Agricultural Soil

    Directory of Open Access Journals (Sweden)

    Dinesh Adhikari

    2017-12-01

    Full Text Available Improvement of phosphorus circulation in the soil is necessary to enhance phosphorus availability to plants. Phosphorus circulation activity is an index of soil’s ability to supply soluble phosphorus from organic phosphorus in the soil solution. To understand the relationship among phosphorus circulation activity; bacterial biomass; pH; and Fe, Al, and Ca concentrations (described as mineral concentration in this paper in agricultural soil, 232 soil samples from various agricultural fields were collected and analyzed. A weak relationship between phosphorus circulation activity and bacterial biomass was observed in all soil samples (R2 = 0.25, and this relationship became significantly stronger at near-neutral pH (6.0–7.3; R2 = 0.67. No relationship between phosphorus circulation activity and bacterial biomass was observed at acidic (pH < 6.0 or alkaline (pH > 7.3 pH. A negative correlation between Fe and Al concentrations and phosphorus circulation activity was observed at acidic pH (R2 = 0.72 and 0.73, respectively, as well as for Ca at alkaline pH (R2 = 0.64. Therefore, bacterial biomass, pH, and mineral concentration should be considered together for activation of phosphorus circulation activity in the soil. A relationship model was proposed based on the effects of bacterial biomass and mineral concentration on phosphorus circulation activity. The suitable conditions of bacterial biomass, pH, and mineral concentration for phosphorus circulation activity could be estimated from the relationship model.

  15. Alteration behavior of bentonite barrier of radioactive waste disposal by alkaline solutions. Part 1. Permeability change of compacted bentonite immersed in alkaline solutions

    International Nuclear Information System (INIS)

    Yokoyama, Shingo; Nakamura, Kunihiko

    2010-01-01

    Permeability tests using the compacted bentonites and alkaline solutions were carried out to estimate of alteration behavior and the change of permeability during the alteration reaction. The permeability tests of the compacted bentonites were carried out at 23degC for one week after they were immersed in alkaline solution at 60degC for four weeks (immersing test). After permeability tests, the compacted bentonites were repeatedly tested as the same procedure (i.e. repetition of permeability test and immersing test) at 11 cycles. The compacted bentonites with initial dry density of 1.6 Mg/m 3 were reacted with the different type of the alkaline solutions (deionized water, NaOH (pH=12 and 14), KOH (pH=12 and 14) and Ca(OH) 2 (pH=12)) in each experiments. In the case of deionized water and alkaline solutions of pH12, the mineral compositions of altered bentonite were similar to original bentonite while the exchangeable cations of altered bentonites were changed. No changes of the mineralogical features of montmorillonite in altered bentonites (i.e. illitization, baideritization and increasing of layer charge) were observed in the case of deionized water, pH12-NaOH and pH12-Ca(OH) 2 . The montmorillonite was changed to the illite/smectite interstratified mineral containing about 40% illite like component during the reaction with pH12-KOH. In the case of alkaline solutions with pH14, the component minerals of bentonite (e.g. montmorillonite, quartz and clinoptilolite) were dissolved, consequently secondly minerals (e.g. analcime and phillipsite) were crystallized during experiments. Furthermore, the mineralogical features of montmorillonite were changed as illitization (pH14-KOH), beidellitization (pH14-NaOH and pH14-KOH) and increasing of layer charge (pH14-NaOH and pH14-KOH). No increasing of permeability were observed during the experiment using pH12-NaOH and pH12-Ca(OH) 2 as well as the case of deionized water. In the case of pH12-KOH, the permeability continually

  16. A NBD-based simple but effective fluorescent pH probe for imaging of lysosomes in living cells.

    Science.gov (United States)

    Cao, Xiang-Jian; Chen, Li-Na; Zhang, Xuan; Liu, Jin-Ting; Chen, Ming-Yu; Wu, Qiu-Rong; Miao, Jun-Ying; Zhao, Bao-Xiang

    2016-05-12

    NBDlyso with lysosome-locating morpholine moiety has been developed as a high selective and sensitive fluorescent pH probe. This probe can respond to acidic pH (2.0-7.0) in a short time (less than 1 min) and not almost change after continuously illuminated for an extended period by ultraviolet light. The fluorescence intensity of NBDlyso enhanced 100-fold in acidic solution, with very good linear relationship (R(2) = 0.996). The pKa of probe NBDlyso is 4.10. Therefore, NBDlyso was used to detect lysosomal pH changes successfully. Besides, X-ray crystallography was used to verify the structure of NBDlyso, and the recognition mechanism involving photo-induced electron transfer was interpreted theoretically by means of DFT and TDDFT calculations skillfully when NBDlyso comes into play under the acidic condition. This probe showed good ability to sense pH change in living cell image. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. PH responsive self-assembly of cucurbit[7]urils and polystyrene-block- polyvinylpyridine micelles for hydrophobic drug delivery

    KAUST Repository

    Moosa, Basem; Mashat, A.; Li, W.; Fhayli, K.; Khashab, Niveen M.

    2013-01-01

    Polystyrene-block-polyvinylpyridine (PS-b-P4VP) polypseudorotaxanes with cucurbit[7]urils (CB[7]) were prepared from water soluble PS-b-P4VPH+ polymer and CB[7] in aqueous solution at room temperature. At acidic and neutral pH, the pyridinium block of PS-b-P4VP is protonated (PS-b-P4VPH +) pushing CB[7] to preferably host the P4VP block. At basic pH (pH 8), P4VP is not charged and thus is not able to strongly complex CB[7]. This phenomenon was verified further by monitoring the release of pyrene, a hydrophobic cargo model, from a PS-b-P4VPH+/CB[7] micellar membrane. Release study of UV active pyrene from the membrane at different pH values revealed that the system is only operational under basic conditions and that the host-guest interaction of CB[7] with P4VPH+ significantly slows down cargo release.

  18. The effect of pH on the erosion of dentine and enamel by dietary acids in vitro.

    Science.gov (United States)

    West, N X; Hughes, J A; Addy, M

    2001-09-01

    The reported incidence of tooth erosion caused by acidic soft drinks has been increasingly documented. Citric and phosphoric acids are the two main dietary acids present in these soft drinks. Many variables need to be determined in order to assess risk factors for dental erosion caused by beverage consumption including pH, titratable acidity, pKa, buffering capacity, hence the aim of these in vitro investigations. Methodologies included profiling flat enamel and dentine samples (acidic solutions adjusted with alkali over the available pH range; citric, phosphoric and hydrochloric acid were adjusted with sodium hydroxide and citric acid with trisodium citrate. Tissue loss was calculated by profilometry. Results showed that under these conditions citric acid caused far more erosion over the pH range employed than phosphoric acid for both tissue types. Citric acid compared with hydrochloric acid highlighted dissolution and chelation effects. Phosphoric acid caused minimal erosion over pH 3 for enamel and pH 4 for dentine. These factors could be considered in order to reduce the erosivity of acidic soft drinks.

  19. Corrosion Effects on the Fatigue Crack Propagation of Giga-Grade Steel and its Heat Affected Zone in pH Buffer Solutions for Automotive Application

    Science.gov (United States)

    Lee, H. S.

    2018-03-01

    Corrosion fatigue crack propagation test was conducted of giga-grade steel and its heat affected zone in pH buffer solutions, and the results were compared with model predictions. Pure corrosion effect on fatigue crack propagation, particularly, in corrosive environment was evaluated by means of the modified Forman equation. As shown in results, the average corrosion rate determined from the ratio of pure corrosion induced crack length to entire crack length under a cycle load were 0.11 and 0.37 for base metal and heat affected zone, respectively, with load ratio of 0.5, frequency of 0.5 and pH 10.0 environment. These results demonstrate new interpretation methodology for corrosion fatigue crack propagation enabling the pure corrosion effects on the behavior to be determined.

  20. Removal of NO from flue gas by aqueous chlorine-dioxide scrubbing solution in a lab-scale bubbling reactor.

    Science.gov (United States)

    Deshwal, Bal Raj; Jin, Dong Seop; Lee, Si Hyun; Moon, Seung Hyun; Jung, Jong Hyeon; Lee, Hyung Keun

    2008-02-11

    The present study attempts to clean up nitric oxide from the simulated flue gas using aqueous chlorine-dioxide solution in the bubbling reactor. Chlorine-dioxide is generated by chloride-chlorate process. Experiments are carried out to examine the effect of various operating variables like input NO concentration, presence of SO(2), pH of the solution and NaCl feeding rate on the NO(x) removal efficiency at 45 degrees C. Complete oxidation of nitric oxide into nitrogen dioxide occurred on passing sufficient ClO(2) gas into the scrubbing solution. NO is finally converted into nitrate and ClO(2) is reduced into chloride ions. A plausible reaction mechanism concerning NO(x) removal by ClO(2) is suggested. DeNO(x) efficiency increased slightly with the increasing input NO concentration. The presence of SO(2) improved the NO(2) absorption but pH of solution showed marginal effect on NO(2) absorption. NO(x) removal mechanism changed when medium of solution changed from acidic to alkaline. A constant NO(x) removal efficiency of about 60% has been achieved in the wide pH range of 3-11 under optimized conditions.

  1. Experimental measurements of the solubility of technetium under near-field conditions

    International Nuclear Information System (INIS)

    Pilkington, N.J.; Wilkins, J.D.

    1988-05-01

    The solubility of technetium in contact with hydrated technetium dioxide under near-field conditions has been measured experimentally. The values obtained were changed little by a change in pH or in the filtration method used. The presence of organic degradation products increased slightly the solution concentration of technetium. (author)

  2. pH and electric conductivity study of H{sub 2}O/MEG/salt systems on monoethyleneglycol (MEG) reclamation units in gas processing; Estudo de pH e condutividade eletrica em sistemas H{sub 2}O/MEG/sal, em unidades de recuperacao de monoetilenoglicol (MEG), no processamento de gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Senna, Camila; Carrijo, Darley; Nascimento, Jailton; Grava, Wilson [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas (CENPES); Lemos, Alessandro A.; Andrade, Wander V.; Chiavone-Filho, Osvaldo; Amorim, Josinira Antunes de [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Dept. de Engenharia Quimica

    2008-07-01

    The monoethylene glycol (MEG) is injected in natural gas production wells in order to combine with the free water, altering the thermodynamic conditions for the formation of hydrates. The presence of MEG in aqueous solutions containing salts provokes the decrease of the solubility of the same ones. Information of properties as the pH and the conductivity are important for the control of the process. Before this, the present work has as objective determines the behavior of the aqueous solutions with MEG and NaCl in pH and conductivity terms, in different temperatures, with views to the stage of recovery of MEG and the salt precipitation beginning. The experimental methodology consisted of the elaboration of synthetic solutions of the mixtures in study, covering every MEG concentration range and temperature between 5 and 90 deg C. The conductivity results for the system H{sub 2}O+MEG showed that the conductivity decreases with the concentration of MEG and it increases with the temperature. A conductivity increase was observed for diluted concentrations of MEG, due to the most pronounced effect of protonation of MEG. For pH measures, it was necessary to develop a calibration procedure due to the fact that this property varies with the solvent media. The pH values decrease as it increases the concentration of MEG, reaching a value practically constant around 40%. (author)

  3. Progress of research on the influence of alkaline cation and alkaline solution on bentonite properties

    International Nuclear Information System (INIS)

    Ye Weimin; Zheng Zhenji; Chen Bao; Chen Yonggui

    2011-01-01

    Based on the previous laboratory studies and numerical simulation on bentonite in alkaline environments, the effects of alkaline cation and alkaline solution on mineral composition, microstructure, swelling capacity and hydraulic properties of bentonite are emphasized in this paper, temperature, pH values and concentration are discussed as main affecting factors. When bentonite is exposed to alkaline cation or alkaline solution, microstructure of bentonite will be changed due to the dissolution of montmorillonite and the formation of secondary minerals, which results in the decrease of swelling pressure. The amount of the reduction of swelling pressure depends on the concentration of alkaline solution. Temperature, polyvalent cation, salinity and concentration are the main factors affecting hydraulic properties of bentonite under alkaline conditions. Therefore, future research should focus on the mechanism of coupling effects of weak alkaline solutions on the mineral composition, microstructure, swelling capacity and hydraulic properties of bentonite under different temperatures and different pH values. (authors)

  4. Influence of pH on the transport of nanoscale zinc oxide in saturated porous media

    Energy Technology Data Exchange (ETDEWEB)

    Kanel, Sushil R. [Pegasus Technical Services, Inc. (United States); Al-Abed, Souhail R., E-mail: al-abed.souhail@epa.gov [National Risk Management Research Laboratory, U.S. Environmental Protection Agency (United States)

    2011-09-15

    Widespread use of nanoscale zinc oxide (nZnO) in various fields causes subsurface environment contamination. Even though the transport of dissolved zinc ions in subsurface environments such as soils and sediments has been widely studied, the transport mechanism of nZnO in such environments is poorly understood. In addition, nZnO is often combined with stabilizers or dispersing agents to prevent its aggregation in products. The purpose of this study is to determine the influence of pH on the transport properties of pristine nZnO and carboxymethyl cellulose (CMC) stabilized nZnO (CMC-nZnO) suspensions in silica sand packed column under saturated flow conditions. Transport data were collected at different pHs (pHs: 3, 7, 9, and 11) under 1 mL/min flow rate conditions in a 1.1 cm diameter column. It is found that the transport trends of pristine nZnO and CMC-nZnO were different. For pristine nZnO, mobility of total Zn reached a minimum around its point of zero charge (pH 8.9). Whereas in the case of CMC-nZnO, the mobility of total Zn decreased as the pH of the solution pH increased from 3 to 11. ZnO and Zn ion mixture were separated using diafiltration membrane. It showed that most of the nZnO and CMC-nZnO exists as Zn ion at pH 3 before and after eluting from the sand packed column whereas at pH 11, they exist as particles. This study shows the strong influence of pH and stabilizing agents on nZnO transport. These factors should be considered during subsurface transport of nZnO.

  5. Influence of pH on the transport of nanoscale zinc oxide in saturated porous media

    International Nuclear Information System (INIS)

    Kanel, Sushil R.; Al-Abed, Souhail R.

    2011-01-01

    Widespread use of nanoscale zinc oxide (nZnO) in various fields causes subsurface environment contamination. Even though the transport of dissolved zinc ions in subsurface environments such as soils and sediments has been widely studied, the transport mechanism of nZnO in such environments is poorly understood. In addition, nZnO is often combined with stabilizers or dispersing agents to prevent its aggregation in products. The purpose of this study is to determine the influence of pH on the transport properties of pristine nZnO and carboxymethyl cellulose (CMC) stabilized nZnO (CMC–nZnO) suspensions in silica sand packed column under saturated flow conditions. Transport data were collected at different pHs (pHs: 3, 7, 9, and 11) under 1 mL/min flow rate conditions in a 1.1 cm diameter column. It is found that the transport trends of pristine nZnO and CMC–nZnO were different. For pristine nZnO, mobility of total Zn reached a minimum around its point of zero charge (pH 8.9). Whereas in the case of CMC–nZnO, the mobility of total Zn decreased as the pH of the solution pH increased from 3 to 11. ZnO and Zn ion mixture were separated using diafiltration membrane. It showed that most of the nZnO and CMC–nZnO exists as Zn ion at pH 3 before and after eluting from the sand packed column whereas at pH 11, they exist as particles. This study shows the strong influence of pH and stabilizing agents on nZnO transport. These factors should be considered during subsurface transport of nZnO.

  6. Electrochemical Impedance Spectroscopic Analysis of RuO2 Based Thick Film pH Sensors

    International Nuclear Information System (INIS)

    Manjakkal, Libu; Djurdjic, Elvira; Cvejin, Katarina; Kulawik, Jan; Zaraska, Krzysztof; Szwagierczak, Dorota

    2015-01-01

    The conductimetric interdigitated thick film pH sensors based on RuO 2 were fabricated and their electrochemical reactions with solutions of different pH values were studied by electrochemical impedance spectroscopy (EIS) technique. The microstructural properties and composition of the sensitive films were examined by scanning electron microscopy, X-ray energy dispersive spectroscopy and Raman spectroscopy. The EIS analysis of the sensor was carried out in the frequency range 10 mHz–2 MHz for pH values of test solutions 2–12. The electrical parameters of the sensor were found to vary with changing pH. The conductance and capacitance of the film were distinctly dependent on pH in the low frequency range. The Nyquist and Bode plots derived from the impedance data for the metal oxide thick film pH sensor provided information about the underlying electrochemical reactions

  7. Positive nondecreasing solutions for a multi-term fractional-order functional differential equation with integral conditions

    OpenAIRE

    Ahmed M. A. El-Sayed; Ebtisam O. Bin-Taher

    2011-01-01

    In this article, we prove the existence of positive nondecreasing solutions for a multi-term fractional-order functional differential equations. We consider Cauchy boundary problems with: nonlocal conditions, two-point boundary conditions, integral conditions, and deviated arguments.

  8. Decomposition kinetics of aminoborane in aqueous solutions

    International Nuclear Information System (INIS)

    Shvets, I.B.; Erusalimchik, I.G.

    1984-01-01

    Kinetics of aminoborane hydrolysis has been studied using the method of polarization galvanostatical curves on a platinum electrode in buffer solutions at pH 3; 5; 7. The supposition that the reaction of aminoborane hydrolysis is the reaction of the first order by aminoborane is proved. The rate constant of aminoborane decomposition in the solution with pH 5 is equal to: K=2.5x10 -5 s -1 and with pH 3 it equals K=1.12x10 -4 s -1

  9. A NBD-based simple but effective fluorescent pH probe for imaging of lysosomes in living cells

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Xiang-Jian [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Chen, Li-Na [Institute of Developmental Biology, School of Life Science, Shandong University, Jinan 250100 (China); Zhang, Xuan [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Liu, Jin-Ting [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Chen, Ming-Yu [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Wu, Qiu-Rong [Institute of Developmental Biology, School of Life Science, Shandong University, Jinan 250100 (China); Taishan College, Shandong University, Jinan 250100 (China); Miao, Jun-Ying, E-mail: miaojy@sdu.edu.cn [Institute of Developmental Biology, School of Life Science, Shandong University, Jinan 250100 (China); Zhao, Bao-Xiang, E-mail: bxzhao@sdu.edu.cn [Institute of Organic Chemistry, School of Chemistry and Chemical Engineering, Shandong University, Jinan 250100 (China)

    2016-05-12

    NBDlyso with lysosome-locating morpholine moiety has been developed as a high selective and sensitive fluorescent pH probe. This probe can respond to acidic pH (2.0–7.0) in a short time (less than 1 min) and not almost change after continuously illuminated for an extended period by ultraviolet light. The fluorescence intensity of NBDlyso enhanced 100-fold in acidic solution, with very good linear relationship (R{sup 2} = 0.996). The pK{sub a} of probe NBDlyso is 4.10. Therefore, NBDlyso was used to detect lysosomal pH changes successfully. Besides, X-ray crystallography was used to verify the structure of NBDlyso, and the recognition mechanism involving photo-induced electron transfer was interpreted theoretically by means of DFT and TDDFT calculations skillfully when NBDlyso comes into play under the acidic condition. This probe showed good ability to sense pH change in living cell image. - Highlights: • An effective NBD-based fluorescent pH probe was developed. • The sensing mechanism was interpreted by theoretical calculation. • This probe was successfully used to monitor lysosoml pH changes in Hela cells.

  10. A NBD-based simple but effective fluorescent pH probe for imaging of lysosomes in living cells

    International Nuclear Information System (INIS)

    Cao, Xiang-Jian; Chen, Li-Na; Zhang, Xuan; Liu, Jin-Ting; Chen, Ming-Yu; Wu, Qiu-Rong; Miao, Jun-Ying; Zhao, Bao-Xiang

    2016-01-01

    NBDlyso with lysosome-locating morpholine moiety has been developed as a high selective and sensitive fluorescent pH probe. This probe can respond to acidic pH (2.0–7.0) in a short time (less than 1 min) and not almost change after continuously illuminated for an extended period by ultraviolet light. The fluorescence intensity of NBDlyso enhanced 100-fold in acidic solution, with very good linear relationship (R"2 = 0.996). The pK_a of probe NBDlyso is 4.10. Therefore, NBDlyso was used to detect lysosomal pH changes successfully. Besides, X-ray crystallography was used to verify the structure of NBDlyso, and the recognition mechanism involving photo-induced electron transfer was interpreted theoretically by means of DFT and TDDFT calculations skillfully when NBDlyso comes into play under the acidic condition. This probe showed good ability to sense pH change in living cell image. - Highlights: • An effective NBD-based fluorescent pH probe was developed. • The sensing mechanism was interpreted by theoretical calculation. • This probe was successfully used to monitor lysosoml pH changes in Hela cells.

  11. Histidine-functionalized water-soluble nanoparticles for biomimetic nucleophilic/general-base catalysis under acidic conditions.

    Science.gov (United States)

    Chadha, Geetika; Zhao, Yan

    2013-10-21

    Cross-linking the micelles of 4-dodecyloxybenzyltripropargylammonium bromide by 1,4-diazidobutane-2,3-diol in the presence of azide-functionalized imidazole derivatives yielded surface-cross-linked micelles (SCMs) with imidazole groups on the surface. The resulting water-soluble nanoparticles were found, by fluorescence spectroscopy, to contain hydrophobic binding sites. The imidazole groups promoted the photo-deprotonation of 2-naphthol at pH 6 and catalyzed the hydrolysis of p-nitrophenylacetate (PNPA) in aqueous solution at pH ≥ 4. Although the overall hydrolysis rate slowed down with decreasing solution pH, the catalytic effect of the imidazole became stronger because the reactions catalyzed by unfunctionalized SCMs slowed down much more. The unusual ability of the imidazole–SCMs to catalyze the hydrolysis of PNPA under acidic conditions was attributed to the local hydrophobicity and the positive nature of the SCMs.

  12. Modified Organosilica Core-Shell Nanoparticles for Stable pH Sensing in Biological Solutions.

    Science.gov (United States)

    Robinson, Kye J; Huynh, Gabriel T; Kouskousis, Betty P; Fletcher, Nicholas L; Houston, Zachary H; Thurecht, Kristofer J; Corrie, Simon R

    2018-04-19

    Continuous monitoring using nanoparticle-based sensors has been successfully employed in complex biological systems, yet the sensors still suffer from poor long-term stability partially because of the scaffold materials chosen to date. Organosilica core-shell nanoparticles containing a mixture of covalently incorporated pH-sensitive (shell) and pH-insensitive (core) fluorophores is presented as a continuous pH sensor for application in biological media. In contrast to previous studies focusing on similar materials, we sought to investigate the sensor characteristics (dynamic range, sensitivity, response time, stability) as a function of material properties. The ratio of the fluorescence intensities at specific wavelengths was found to be highly sensitive to pH over a physiologically relevant range (4.5-8) with a response time of pH-specific signals when stored at room temperature for more than 80 days. Finally, we demonstrated that the nanosensors successfully monitored the pH of a bacterial culture over 15 h and that pH changes in the skin of mouse cadavers could also be observed via in vivo fluorescence imaging following subcutaneous injection. The understanding gained from linking sensor characteristics and material properties will inform the next generation of optical nanosensors for continuous-monitoring applications.

  13. Structural Characterization of the Degradation Products of a Minor Natural Sweet Diterpene Glycoside Rebaudioside M under Acidic Conditions

    Directory of Open Access Journals (Sweden)

    Indra Prakash

    2014-01-01

    Full Text Available Degradation of rebaudioside M, a minor sweet component of Stevia rebaudiana Bertoni, under conditions that simulated extreme pH and temperature conditions has been studied. Thus, rebaudioside M was treated with 0.1 M phosphoric acid solution (pH 2.0 and 80 °C temperature for 24 h. Experimental results indicated that rebaudioside M under low pH and higher temperature yielded three minor degradation compounds, whose structural characterization was performed on the basis of 1D (1H-, 13C- & 2D (COSY, HSQC, HMBC NMR, HRMS, MS/MS spectral data as well as enzymatic and acid hydrolysis studies.

  14. Effects of pH on the crystallographic structure and magnetic properties of electrodeposited cobalt nanowires

    International Nuclear Information System (INIS)

    Zafar, N.; Shamaila, S.; Sharif, R.; Wali, H.; Naseem, S.; Riaz, S.; Khaleeq-ur-Rahman, M.

    2015-01-01

    Anodic aluminum oxide templates with pore diameter of 40 nm and inter pore separation of 100 nm are prepared by two step anodization in 0.3 M oxalic acid solution. These templates are used to fabricate dc-deposited Co nanowires at different pH values of acidic bath. Continuous and densely packed nanowires having length ∼8 µm are observed. The hcp configuration appeared at moderate and high pH whereas both fcc and hcp phases are observed at low pH. However the crystallinity distorted at high pH due to formation of polycrystalline structure of cobalt nanowires. Alignment of easy-axis of nanowires can be tailored by varying pH of solution. - Highlights: • Variation in the structure of dc deposited cobalt nanowires can be obtained by varying pH of acidic bath. • The hcp structure is stable at room temperature with low voltage deposition for electrodeposited Co nanowires. Co with fcc structure, is stable at temperatures above 422 °C or at pH<3 with high potential. • The hcp (100) plane is obtained with pH∼3.5 and (101) is stable at pH∼5.5 due to variation in temperature inside the pores with respect to the pH. • Alignment of easy-axis of nanowires can be tailored by varying pH of solution

  15. Iodine evolution and pH control

    International Nuclear Information System (INIS)

    Beahm, E.C.; Lorenz, R.A.; Weber, C.F.

    1993-01-01

    The pH is the major factor in determining the extent of I 2 in solution. In containment where no pH-control chemicals are present, the acidity or basicity of the water pool will be determined by materials that are introduced into containment as a result of the accident itself. These materials may be fission products (i.e., cesium compounds), thermally produced products (i.e., core-concrete aerosols), or compounds produced by radiation (i.e., nitric acid). In situations where pH levels fall below ∼7, the formation of I 2 will occur in irradiated iodide solutions. A correlation between pH and iodine formation is needed so that the amounts I 2 in water pools can be assessed. This, in turn, determines the amount of I 2 in the atmosphere available for escape by containment leakage. A number of calculational routines based on more than 100 differential equations representing individual reactions can be found in the literature. In this work, it is shown that a simpler approach based on the steady-state decomposition of hydrogen peroxide should correctly describe iodine formation in severe accidents. Comparisons with test data show this approach to be valid. The most important acids in containment will be nitric acid (HNO 3 ), produced by irradiation of water and air, and hydrochloric acid (HCl), produced by irradiation or heating of electrical cable insulation. The most important bases in containment will be cesium hydroxide, cesium borate (or cesium carbonate), and in some plants pH additives, such as sodium hydroxide or sodium phosphate

  16. Dependency of the band gap of electrodeposited Copper oxide thin films on the concentration of copper sulfate (CuSO4.5H2O) and pH in bath solution for photovoltaic applications

    KAUST Repository

    Islam, Md. Anisul

    2016-03-10

    In this study, Copper oxide thin films were deposited on copper plate by electrodeposition process in an electrolytic bath containing CuSO4.5H2O, 3M lactic acid and NaOH. Copper oxide films were electrodeposited at different pH and different concentration of CuSO4.5H2O and the optical band gap was determined from their absorption spectrum which was obtained from UV-Vis absorption spectroscopy. It was found that copper oxide films which were deposited at low concentration of CuSO4.5H2O have higher band gap than those deposited at higher bath concentration. The band gap of copper oxide films also significantly changes with pH of the bath solution. It was also observed that with the increase of the pH of bath solution band gap of copper oxide film decreased. © 2015 IEEE.

  17. Colloid mobilization and heavy metal transport in the sampling of soil solution from Duckum soil in South Korea.

    Science.gov (United States)

    Lee, Seyong; Ko, Il-Won; Yoon, In-Ho; Kim, Dong-Wook; Kim, Kyoung-Woong

    2018-03-24

    Colloid mobilization is a significant process governing colloid-associated transport of heavy metals in subsurface environments. It has been studied for the last three decades to understand this process. However, colloid mobilization and heavy metal transport in soil solutions have rarely been studied using soils in South Korea. We investigated the colloid mobilization in a variety of flow rates during sampling soil solutions in sand columns. The colloid concentrations were increased at low flow rates and in saturated regimes. Colloid concentrations increased 1000-fold higher at pH 9.2 than at pH 7.3 in the absence of 10 mM NaCl solution. In addition, those were fourfold higher in the absence than in the presence of the NaCl solution at pH 9.2. It was suggested that the mobility of colloids should be enhanced in porous media under the basic conditions and the low ionic strength. In real field soils, the concentrations of As, Cr, and Pb in soil solutions increased with the increase in colloid concentrations at initial momentarily changed soil water pressure, whereas the concentrations of Cd, Cu, Fe, Ni, Al, and Co lagged behind the colloid release. Therefore, physicochemical changes and heavy metal characteristics have important implications for colloid-facilitated transport during sampling soil solutions.

  18. Effect of pH on the optical and structural properties of HfO{sub 2}:Ln{sup 3+}, synthesized by hydrothermal route

    Energy Technology Data Exchange (ETDEWEB)

    Montes, E., E-mail: emontesr@live.com.mx [Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada IPN, Legaría 694, 11500, D.F. (Mexico); Martínez-Merlín, I.; Guzmán-Olguín, J.C.; Guzmán-Mendoza, J. [Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada IPN, Legaría 694, 11500, D.F. (Mexico); Martín, I.R. [Depto. de Física Fundamental y Experimental, Electrónica y Sistemas, Univ. de La Laguna, Av. Astrofísico Francisco Sánchez s/n E-38206, La Laguna. Tenerife (Spain); García-Hipólito, M. [Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México, Circuito Exterior, Cd. Universitaria, 04510, D.F. (Mexico); Falcony, C. [Departamento de Física, CINVESTAV IPN, Apartado Postal 14-740, 07000, D.F. (Mexico)

    2016-07-15

    In this work, the influence of the chlorine ions in the optical and structural properties of hafnium oxide (HfO{sub 2}) doped with europium (Eu{sup 3+}) and terbium (Tb{sup 3+}) are reported. The synthesis was conducted by hydrothermal route at a temperature of 200 °C, with a reaction time of 80 min and a concentration of 3 mol% of both dopants, in relation to hafnium in solution. In order to study the influence of acidity on the kinetics of reaction, the pH of the precursor solution was varied in the range of pH=4 to pH=12. X-ray powder diffraction patterns showed that the materials crystallized better under alkaline conditions with pH=11, noting a better crystallinity in the material doped with Eu{sup 3+}showed a better crystallinity that Tb{sup 3+} ions. The characteristic rhombohedral microstructure of HfO{sub 2} in the monoclinic phase was observed in alkaline media. Photoluminescent spectra showed the characteristic peaks of the emissions for both Eu an Tb dopants, where the intensity of the luminescent emission increases by decreasing the concentration of chlorine ions. On the other hand, it was found that radiative life kinetics of the dopant is related to the kinetics of crystallization, and therefore, to the acidity of the precursor solution.

  19. The role of pH variation on the growth of zinc oxide nanostructures

    International Nuclear Information System (INIS)

    Wahab, Rizwan; Ansari, S.G.; Kim, Young Soon; Song, Minwu; Shin, Hyung-Shik

    2009-01-01

    In this paper we present a systematic study on the morphological variation of ZnO nanostructure by varying the pH of precursor solution via solution method. Zinc acetate dihydrate and sodium hydroxide were used as a precursor, which was refluxed at 90 deg. C for an hour. The pH of the precursor solution (zinc acetate di hydrate) was increased from 6 to 12 by the controlled addition of sodium hydroxide (NaOH). Morphology of ZnO nanorods markedly varies from sheet-like (at pH 6) to rod-like structure of zinc oxide (pH 10-12). Diffraction patterns match well with standard ZnO at all pH values. Crystallinity and nanostructures were confirmed by high-resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED) pattern, which indicates structure grew along [0 0 0 1] direction with an ideal lattice fringes distance 0.52 nm. FTIR spectroscopic measurement showed a standard peak of zinc oxide at 464 cm -1 . Amount of H + and OH - ions are found key to the structure control of studied material, as discussed in the growth mechanism.

  20. PROCESS FOR RECOVERY OF URANIUM VALUES FROM IMPURE SOLUTIONS THEREOF

    Science.gov (United States)

    Kilner, S.B.

    1959-11-01

    A process is presented for the recovery of uraninm values from impure solutions which are obtained, for example, by washing residual uranium salt or uranium metal deposits from stainless steel surfaces using an aqueous or certain acidic aqueous solutions. The solutions include uranyl and oxidized iron, chromium, nickel, and copper ions and may contain manganese, zinc, and silver ions. In accordance with one procedure. the uranyl ions are reduced to the uranous state, and the impurity ions are complexed with cyanide under acidic conditions. The solution is then treated with ammonium hydroxide or alkali metal hydroxide to precipitate uranous hydroxide away from the complexed impurity ions in the solution. Alternatively, an excess of alkali metal cyanide is added to the reduced solution until the solution becomes sufficiently alkaline for the uranons hydroxide to precipitate. An essential feature in operating the process is in maintaining the pH of the solution sufficiently acid during the complexing operation to prevent the precipitation of the impurity metal hydroxides.

  1. Investigation of the removal of chromium (VI by Nanocomposites Chitosan-tragacanth solution from aqueous solution

    Directory of Open Access Journals (Sweden)

    Adel Almasi Nahnaji

    2016-03-01

    Full Text Available Background: The aim of this study was to investigate the removal of chromium (VI by Nanocomposites Chitosan-tragacanth solution from aqueous solution. Methods: In this study, chitosan-tragacanth nanocomposites were synthesized and analyzed by electron microscopy (SEM, (TEM and Fourier transform spectroscopy (FT-IR for the size and shape of the surface. The nano-composite of chitosan-tragacanth, for the adsorption of chromium (VI in aqueous solution was used as adsorbent. Results: The optimum conditions with multiple experiments to enhance the absorption were evaluated. The highest absorption of Cr (VI was occurred in the adsorbent dosage of 0.2 g, 8 ppm concentration of chromium ions, the pH=6 and also retention time of 50 min; in 298 ˚K temperature. After determining optimal conditions of adsorption, isotherms equations and study and thermodynamic parameters were applied. Adsorption process of chromium (VI on nano-composite chitosan - Tragacanth was conformed with Temkin isotherm. Conclusion: The thermodynamic parameters such as standard Gibbs free energy changes, changes in enthalpy and entropy changes in the standard showed that the adsorption process of Cr (VI is spontaneous and heating, and kinetics studies of models Lagergren, Ho , Alovich and intraparticle is used, the results show that the adsorption kinetics follows the pseudo-second order.

  2. Variation formulae for the solutions of delay differential equations with discontinuous initial conditions

    International Nuclear Information System (INIS)

    Kharatishvili, G L; Tadumadze, T A

    2005-01-01

    Variation formulae are proved for solutions of non-linear differential equations with variable delays and discontinuous initial conditions. The discontinuity of the initial condition means that at the initial moment of time the values of the initial function and the trajectory, generally speaking, do not coincide. The formulae obtained contain a new summand connected with the discontinuity of the initial condition and the variation of the initial moment.

  3. Hydro-dynamic Solute Transport under Two-Phase Flow Conditions.

    Science.gov (United States)

    Karadimitriou, Nikolaos K; Joekar-Niasar, Vahid; Brizuela, Omar Godinez

    2017-07-26

    There are abundant examples of natural, engineering and industrial applications, in which "solute transport" and "mixing" in porous media occur under multiphase flow conditions. Current state-of-the-art understanding and modelling of such processes are established based on flawed and non-representative models. Moreover, there is no direct experimental result to show the true hydrodynamics of transport and mixing under multiphase flow conditions while the saturation topology is being kept constant for a number of flow rates. With the use of a custom-made microscope, and under well-controlled flow boundary conditions, we visualized directly the transport of a tracer in a Reservoir-on-Chip (RoC) micromodel filled with two immiscible fluids. This study provides novel insights into the saturation-dependency of transport and mixing in porous media. To our knowledge, this is the first reported pore-scale experiment in which the saturation topology, relative permeability, and tortuosity were kept constant and transport was studied under different dynamic conditions in a wide range of saturation. The critical role of two-phase hydrodynamic properties on non-Fickian transport and saturation-dependency of dispersion are discussed, which highlight the major flaws in parametrization of existing models.

  4. Existence of mild solutions of a semilinear evolution differential inclusions with nonlocal conditions

    Directory of Open Access Journals (Sweden)

    Reem A. Al-Omair

    2009-03-01

    Full Text Available In this paper we prove the existence of a mild solution for a semilinear evolution differential inclusion with nonlocal condition and governed by a family of linear operators, not necessarily bounded or closed, in a Banach space. No compactness assumption is assumed on the evolution operator generated by the family operators. Also, we prove that the set of mild solutions is compact.

  5. Stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride and polyolefin bags.

    Science.gov (United States)

    Karlage, Kelly; Earhart, Zachary; Green-Boesen, Kelly; Myrdal, Paul B

    2011-08-15

    The stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride (PVC) and polyolefin bags under varying conditions was evaluated. Triplicate solutions of midazolam hydrochloride 1-mg/mL were prepared in polyolefin and PVC i.v. bags by diluting midazolam hydrochloride injection 5 mg/mL with 5% dextrose injection. Bags were then stored under refrigeration (3-4 °C), exposed to light at room temperature (20-25 °C), or protected from light in amber bags at room temperature. Samples were taken immediately after preparation (day 0) and on days 1, 2, 3, 6, 13, 20, and 27 for analysis with a stability-indicating high-performance liquid chromatography assay in order to determine solution concentration. Stability was defined as retention of at least 90% of the initial drug concentration. The pH of each solution was also measured weekly. Sterility of the i.v. bags was determined at the end of the study by microbiological testing with culture in growth media. Differences in concentrations under the various storage conditions and bags used were analyzed using analysis of variance. All solutions retained over 98% of the initial midazolam hydrochloride concentration, with no statistically significant (p ≥ 0.05) change in concentration over the four-week period. Stability was not affected by temperature, exposure to light, or bag type. The pH of all solutions remained between 3.2 and 3.4 throughout the study. Sterility after 28 days was retained. Midazolam hydrochloride 1-mg/mL solutions diluted in 5% dextrose injection remained stable over 27 days in both polyolefin and PVC i.v. bags, regardless of storage condition.

  6. Positive nondecreasing solutions for a multi-term fractional-order functional differential equation with integral conditions

    Directory of Open Access Journals (Sweden)

    Ahmed M. A. El-Sayed

    2011-12-01

    Full Text Available In this article, we prove the existence of positive nondecreasing solutions for a multi-term fractional-order functional differential equations. We consider Cauchy boundary problems with: nonlocal conditions, two-point boundary conditions, integral conditions, and deviated arguments.

  7. The photodegradation of trichloroethylene with or without the NAPL by UV irradiation in surfactant solutions

    Energy Technology Data Exchange (ETDEWEB)

    Jia Juncai [Department of Civil and Structural Engineering, Research Centre for Urban Environmental Technology and Management, Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong); Chu, W. [Department of Civil and Structural Engineering, Research Centre for Urban Environmental Technology and Management, Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong)], E-mail: cewchu@polyu.edu.hk

    2009-01-15

    The photodegradation of trichloroethene (TCE) with or without nonaqueous phase liquids (NAPL) by ultraviolet irradiation in surfactant solutions was examined in this study. The photodecay of TCE was studied at monochromatic 254 nm UV lamps. The effects of the type of surfactants, initial surfactant concentrations, pH levels and NAPL concentrations were examined to explore the photodecay of TCE. All the photodegradation of TCE followed pseudo-first-order decay kinetics at various conditions. It was found that Brij 35 overdose and higher initial pH levels may retard or inhibit the photodecay of TCE, mainly due to protons, intermediate generation and change of surfactant structure in the processes. The optimal condition for TCE photodecay was suggested based on the analysis of kinetics data, from which the reaction mechanism of TCE in the presence of NAPL form was also studied. In general, the reactions of TCE in micellar solution and NAPL pool can be considered as independent pathways due to the low molecule diffusion between the two phases.

  8. Electrochemical treatment of Orange II dye solution-Use of aluminum sacrificial electrodes and floc characterization

    International Nuclear Information System (INIS)

    Mollah, M. Yousuf A.; Gomes, Jewel A.G.; Das, Kamol K.; Cocke, David L.

    2010-01-01

    Electrocoagulation (EC) of Orange II dye in a flow through cell with aluminum as sacrificial electrodes was carried out under varying conditions of dye concentration, current density, flow rate, conductivity, and the initial pH of the solution in order to optimize the operating parameters for maximum benefits. Maximum removal efficiency of 94.5% was obtained at the following conditions: dye concentration = 10 ppm, current density = 160 A/m 2 , initial pH 6.5, conductance = 7.1 mS/cm, flow rate = 350 mL/min, and concentration of added NaCl = 4.0 g/L of dye solution. The EC-floc was characterized using Fourier transform infrared spectroscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy, and powder X-ray diffraction techniques. The removal mechanism has been proposed that is in compliance with the Pourbaix diagram, solubility curve of aluminum oxides/hydroxides, and physico-chemical properties of the EC-floc.

  9. Electrochemical treatment of Orange II dye solution-Use of aluminum sacrificial electrodes and floc characterization

    Energy Technology Data Exchange (ETDEWEB)

    Mollah, M. Yousuf A. [Department of Chemistry, University of Dhaka, Dhaka-1000 (Bangladesh); Gomes, Jewel A.G., E-mail: jewel.gomes@lamar.edu [Dan F. Smith Department of Chemical Engineering, Lamar University, P.O. Box 10053, Beaumont, TX 77710 (United States); Das, Kamol K.; Cocke, David L. [Gill Chair of Chemical Engineering, Lamar University, P.O. Box 10053, Beaumont, TX 77710 (United States)

    2010-02-15

    Electrocoagulation (EC) of Orange II dye in a flow through cell with aluminum as sacrificial electrodes was carried out under varying conditions of dye concentration, current density, flow rate, conductivity, and the initial pH of the solution in order to optimize the operating parameters for maximum benefits. Maximum removal efficiency of 94.5% was obtained at the following conditions: dye concentration = 10 ppm, current density = 160 A/m{sup 2}, initial pH 6.5, conductance = 7.1 mS/cm, flow rate = 350 mL/min, and concentration of added NaCl = 4.0 g/L of dye solution. The EC-floc was characterized using Fourier transform infrared spectroscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy, and powder X-ray diffraction techniques. The removal mechanism has been proposed that is in compliance with the Pourbaix diagram, solubility curve of aluminum oxides/hydroxides, and physico-chemical properties of the EC-floc.

  10. The photodegradation of trichloroethylene with or without the NAPL by UV irradiation in surfactant solutions

    International Nuclear Information System (INIS)

    Jia Juncai; Chu, W.

    2009-01-01

    The photodegradation of trichloroethene (TCE) with or without nonaqueous phase liquids (NAPL) by ultraviolet irradiation in surfactant solutions was examined in this study. The photodecay of TCE was studied at monochromatic 254 nm UV lamps. The effects of the type of surfactants, initial surfactant concentrations, pH levels and NAPL concentrations were examined to explore the photodecay of TCE. All the photodegradation of TCE followed pseudo-first-order decay kinetics at various conditions. It was found that Brij 35 overdose and higher initial pH levels may retard or inhibit the photodecay of TCE, mainly due to protons, intermediate generation and change of surfactant structure in the processes. The optimal condition for TCE photodecay was suggested based on the analysis of kinetics data, from which the reaction mechanism of TCE in the presence of NAPL form was also studied. In general, the reactions of TCE in micellar solution and NAPL pool can be considered as independent pathways due to the low molecule diffusion between the two phases

  11. Modelling of the effect of solute structure and mobile phase pH and composition on the retention of phenoxy acid herbicides in reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Aschi, Massimiliano; D'Archivio, Angelo Antonio; Mazzeo, Pietro; Pierabella, Mirko; Ruggieri, Fabrizio

    2008-01-01

    A feed-forward artificial neural network (ANN) learned by error back-propagation is used to generate a retention predictive model for phenoxy acid herbicides in isocratic reversed-phase high-performance liquid chromatography. The investigated solutes (18 compounds), apart from the most common herbicides of this class, include some derivatives of benzoic acid and phenylacetic acid structurally related to phenoxy acids, as a whole covering a pK a range between 2.3 and 4.3. A mixed model in terms of both solute descriptors and eluent attributes is built with the aim of predicting retention in water-acetonitrile mobile phases within a large range of composition (acetonitrile from 30% to 70%, v/v) and acidity (pH of water before mixing with acetonitrile ranging between 2 and 5). The set of input variables consists of solute pK a and quantum chemical molecular descriptors of both the neutral and dissociated form, %v/v of acetonitrile in the mobile phase and pH of aqueous phase before mixing with acetonitrile. After elimination of redundant variables, a nine-dimensional model is identified and its prediction ability is evaluated by external validation based on three solutes not involved in model generation and by cross-validation. A multilinear counterpart in terms of the same descriptors is seen to provide a noticeably poorer retention prediction

  12. Modelling of the effect of solute structure and mobile phase pH and composition on the retention of phenoxy acid herbicides in reversed-phase high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Aschi, Massimiliano [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)], E-mail: darchivi@univaq.it; Mazzeo, Pietro; Pierabella, Mirko; Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2008-06-02

    A feed-forward artificial neural network (ANN) learned by error back-propagation is used to generate a retention predictive model for phenoxy acid herbicides in isocratic reversed-phase high-performance liquid chromatography. The investigated solutes (18 compounds), apart from the most common herbicides of this class, include some derivatives of benzoic acid and phenylacetic acid structurally related to phenoxy acids, as a whole covering a pK{sub a} range between 2.3 and 4.3. A mixed model in terms of both solute descriptors and eluent attributes is built with the aim of predicting retention in water-acetonitrile mobile phases within a large range of composition (acetonitrile from 30% to 70%, v/v) and acidity (pH of water before mixing with acetonitrile ranging between 2 and 5). The set of input variables consists of solute pK{sub a} and quantum chemical molecular descriptors of both the neutral and dissociated form, %v/v of acetonitrile in the mobile phase and pH of aqueous phase before mixing with acetonitrile. After elimination of redundant variables, a nine-dimensional model is identified and its prediction ability is evaluated by external validation based on three solutes not involved in model generation and by cross-validation. A multilinear counterpart in terms of the same descriptors is seen to provide a noticeably poorer retention prediction.

  13. Synthesis of xenotime(YPO4) by precipitation from aqueous solution

    International Nuclear Information System (INIS)

    Hikichi, Yasuo; Hukuo, Ken-iti; Shiokawa, Jiro.

    1978-01-01

    Xenotime (tetragonal YPO 4 ) was synthesized by the precipitation from a mixed solution of yttrium chloride and orthophosphoric acid or orthophosphate above 50 0 C. At 50 0 C, the initial precipitate from the solutions in the pH range from 0.8 to 2.9 was crystalline weinschenkite (monoclinic YPO 4 .2H 2 O) and amorphous phosphate was formed at pH above 3, while precipitation did not take place at pH 0.5. Weinschenkite was stable at 50 0 C, but amorphous phosphate gradually crystallized by aging and became crystalline xenotime at pH 3.7 after 5 days and at pH 5.0 after 28 days. At 90 0 C, xenotime was detected in the precipitate from the solution of pH 0.5, and was also obtained by aging weinschenkite at pH between 0.8 and 2.9 or amorphous phosphate at pH above 3. The unit cell parameters of the synthesized xenotime were as follows: a=b=6.893A, c=6.026A. (auth.)

  14. pH Responsive Self-Assembly of Cucurbit[7]urils and Polystyrene-Block-Polyvinylpyridine Micelles for Hydrophobic Drug Delivery

    Directory of Open Access Journals (Sweden)

    Basem A. Moosa

    2013-01-01

    Full Text Available Polystyrene-block-polyvinylpyridine (PS-b-P4VP polypseudorotaxanes with cucurbit[7]urils (CB[7] were prepared from water soluble PS-b-P4VPH+ polymer and CB[7] in aqueous solution at room temperature. At acidic and neutral pH, the pyridinium block of PS-b-P4VP is protonated (PS-b-P4VPH+ pushing CB[7] to preferably host the P4VP block. At basic pH (pH 8, P4VP is not charged and thus is not able to strongly complex CB[7]. This phenomenon was verified further by monitoring the release of pyrene, a hydrophobic cargo model, from a PS-b-P4VPH+/CB[7] micellar membrane. Release study of UV active pyrene from the membrane at different pH values revealed that the system is only operational under basic conditions and that the host-guest interaction of CB[7] with P4VPH+ significantly slows down cargo release.

  15. Evaluation of citric acid and GDL in the recovery at different pH levels of Clostridium sporogenes PA 3679 spores subjected to HTST treatment conditions.

    Science.gov (United States)

    Silla Santos, M H; Torres Zarzo, J

    1996-04-01

    Spores of Clostridium sporogenes PA 3679 were treated at different temperatures (121, 126, 130 and 135 degrees C) in white asparagus purée (pH 5.8) and acidified with glucono-delta-lactone (GDL) and citric acid to pH levels of 5.5, 5.0 and 4.5. Afterwards, the spores were recovered in MPA3679 medium in various conditions: unacidified (pH 7.5), acidified with GDL (500 ppm) and acidified with citric acid (500 and 250 ppm) to pH levels of 6.5, 6.0 and 5.0. The results indicated that the pH levels, concentration and type of acid used act synergistically rather than independently. Citric acid has a stronger inhibiting effect than GDL on the recovery of C. sporogenes PA 3679 spores. At the higher heat treatments (130 and 135 degrees C) the major injury on the spores sensitize more than against the acids and low pH values.

  16. Breather type solutions of the vector nonlinear Schroedinger equation with quasi-constant boundary conditions

    International Nuclear Information System (INIS)

    Makhan'kov, V.G.; Slavov, S.I.

    1989-01-01

    Vector nonlinear Schroedinger equations (VS3) is investigated under quasi-constant boundary conditions. New two-soliton solutions are obtained with such non-trivial dynamics that they may be called the breather solutions. A version of the basic Novikov-Dubrovin-Krichever algebro-geometrical approach is applied to obtain breather like solutions existing for all types of internal symmetry is specified are formulated in terms of the soliton velocity expressed via the parameters of the problem. 4 refs

  17. [Effect of the crystallization conditions of tetracycline base on the properties of the powders and drug forms obtained. The dependence of the degree of dispersion of tetracycline base on the crystallization conditions].

    Science.gov (United States)

    Lin'kov, G I; Zhukovskaia, S A; Dzhabarov, D N; Nabokov, V S

    1977-09-01

    Characteristics of the powder dispersity of tetracycline base samples prepared by directed crystallization with variation of the process conditions were determined by the sedimentation method. It was found that the speed of the solution agitation had the maximum effect on the level and nature of the dispersity. The rate of the solution temperature and pH changing during the crystallization process had also a significant effect at low agitation speed.

  18. Plaque pH Changes Following Consumption of Two Types of Plain and Bulky Bread.

    Science.gov (United States)

    Mortazavi, Shiva; Noin, Sogol

    2011-01-01

    Consistency, backing process and content differences could influence cariogenic potential of foods. The aim was to compare plaque pH changes following consumption of two types of bread with different physical characteristics. In this clinical trial, interproximal plaque pH of 10 volunteers with high risk of dental caries (saliva Streptococcus mutans > 10(5), high dental caries experience, and average DMFT =6.10 ± 1.56) was measured. Plain traditionally backed "Sangak bread" and soft bulky "Baguette bread" and %10 sucrose solution were tested in a cross over designed experiment. Baseline plaque pH was recorded and followed by 1, 5, 10, 15, 20, and 30 minutes intervals. Data was analyzed using ANOVA and Tukey test (α = 0.05). Sucrose solution caused the most pronounced pH and ΔpH drop from 7.15 ± 0.33 at baseline to 6.78 ± 0.29. Means plaque pH of 10% sucrose solution and Baguette were not statistically different at 1, 20 and 30 minutes (P > 0.05). Mean plaque pH of Sangak and Baguette showed significant differences at 0, 1, 20 and30 minutes (P bread samples within first 10 minutes, pH increased and then started to decrease during tenth to fifteenth minutes. During all experiment phases, the mean pH of Baguette with less consistency and carbohydrate content and higher rate of starch gelatination was lower compared to Sangak.

  19. Antimony removal from aqueous solutions using Zirconium hydroxide

    International Nuclear Information System (INIS)

    Petrescu, D.; Velciu, L.; Bucur, C.

    2016-01-01

    In this paper it is presented an experimental test for non-radioactive antimony removal from aqueous solutions using zirconium hydroxide powder. Also, it was studied how the temperature and pH influences antimony adsorption onto zirconium hydroxide surface. After the adsorption, solutions were filtered on Cellulose Mixed Ester Membrane with 0.2 μm pore size to remove the zirconium powder and then the aqueous solutions were sent to Inductively Coupled Plasma Optic Emission Spectrometry (ICP-OES) for quantitative analysis of Sb. Zirconium hydroxide powders were examined by optical microscopy. For the solutions that were tested at pH 4.5 and 10.2 the antimony concentration dropped below the detection limit of ICP-OES device, proof of antimony adsorption on zirconium hydroxide. Also, for the other tested solutions which had pH=12 the antimony concentration reduced with 77% and 80%. The temperature had no influence upon adsorption mechanism. (authors)

  20. The Effect of Saccharomyces Strains and Fermentation Condition on the pH, Foam Property and CO2 Concentration of Non-alcoholic Beer (Ma-al-shaeer

    Directory of Open Access Journals (Sweden)

    S. Sohrabvandi

    2014-12-01

    Full Text Available This study aims to determine the effect of fermentation condition and Saccharomyces strains on the pH, foam property and CO2 concentration of non-alcoholic beer (Ma-al-shaeer. For this, the beer samples were inoculated with four different species of Saccharomyces (Saccharomyces rouxii 70531, S. rouxii 70535, S. ludwigii 3447 and S. cerevisiae 70424 and fermented for 48h in both aerobic and periodic aeration at three different temperatures. Then their pH, CO2 concentration and foam property were analyzed in 12h intervals during 48h fermentation. The results shows that the treatments with 4×107 CFU.ml-1 and periodic aeration at 24˚C showed the greatest decrease in pH, and the treatments with 107 CFU.ml-1 and aerobic-periodic aeration at 4˚C showed the lowest decrease in pH. The highest and lowest amounts of CO2 and foam property were obtained in the treatments with 4×107 CFU.ml-1 inoculation, aerobic condition, and the treatments with 107 CFU.ml-1, periodic aeration, respectively. These results further demonstrated that the highest drop in pH, and the highest ability of producing CO2 and foam were for S. cerevisiae 70424, and the lowest belonged to S. rouxii 70531. The overall outcome of the study points to the fact that physico-chemical properties of Ma-al-shaeer is important from the consumers' point of view. Therefore, S. cerevisiae with 4×107 CFU.ml-1 inoculation and aerobic condition at 4˚C has promising potential for producing Ma-al-shaeer with good physicochemical properties.

  1. Mode of de-esterification of alkaline and acidic pectin methyl esterases at different pH conditions.

    Science.gov (United States)

    Duvetter, Thomas; Fraeye, Ilse; Sila, Daniel N; Verlent, Isabel; Smout, Chantal; Hendrickx, Marc; Van Loey, Ann

    2006-10-04

    Highly esterified citrus pectin was de-esterified at pH 4.5 and 8.0 by a fungal pectin methyl esterase (PME) that was shown to have an acidic isoelectric pH (pI) and an acidic pH optimum and by a plant PME that was characterized by an alkaline pI and an alkaline pH optimum. Interchain and intrachain de-esterification patterns were studied by digestion of the pectin products with endo-polygalacturonase and subsequent analysis using size exclusion and anion-exchange chromatography. No effect of pH was observed on the de-esterification mode of either of the two enzymes. Acidic, fungal PME converted pectin according to a multiple-chain mechanism, with a limited degree of multiple attack at the intrachain level, both at pH 4.5 and at pH 8.0. A multiple-attack mechanism, with a high degree of multiple attack, was more appropriate to describe the action mode of alkaline, plant PME, both at pH 4.5 and at pH 8.0.

  2. A Simple Technique for Determining the pH of Whole Cigarette Smoke

    Directory of Open Access Journals (Sweden)

    Dong J

    2014-12-01

    Full Text Available A new technique has been developed to determine the pH of whole cigarette smoke. In this technique, whole smoke from ten cigarettes was trapped in 300 mL water containing 1% (w/v sodium chloride and the pH was determined on the resulting aqueous suspension of cigarette smoke. Two impingers with an extra coarse porosity fritted disc were used to dispense the smoke in the aqueous trapping medium. Cigarettes were smoked on a 20-port Borgwaldt RM 20/CS smoking machine using modified FTC (Federal Trade Commission conditions. The puff volume was adjusted to take a 35 mL puff as measured through the cigarette and the collection traps. This new technique accounts for the contributions to smoke pH from both the vapor phase and the particulate phase of smoke. The repeatability of this new technique was determined on eighteen replicates of a commercially available non-menthol, filter cigarette. Each measurement was done on a different day to check for a possible drift in pH with time. The mean pH value for the chosen sample was found to be 4.97 with a standard deviation of 0.07 pH units. The smoke pH values for over 150 commercially available cigarette brands with a variety of “tar” levels were determined. The smoke pH values had a range from 4.6 to 5.5, with an average of 4.79 and a maximum standard deviation of 0.10 pH units. An experimental flue cured cigarette had a smoke pH of around 5.0, while an experimental Burley cigarette had a smoke pH of 5.4. No correlation between smoke pH and “tar” or total particulate matter (TPM and between pH and nicotine levels was found. The purpose of the present study was to develop a practical, relatively simple laboratory method to measure the pH of a water solution of whole smoke, and was not intended to reflect, or have direct relevance for any biochemical or biological phenomena such as inhalability of smoke, flavor perception, nicotine ab-sorption, etc.”

  3. Removal of Nitrate From Aqueous Solution Using Rice Chaff

    Directory of Open Access Journals (Sweden)

    Dehghani

    2015-09-01

    Full Text Available Background Nitrate is largely dissolved in the surface and ground water, due to its high solubility. Continual uptake of nitrite through drinking water can lead to problems and diseases (such as blue baby for humans, especially children. Objectives The aim of this study was to develop a new and inexpensive method for the removal of nitrate from water. In this regard, the possibility of using chaff for removal of nitrate from aqueous solutions was studied and the optimum operating conditions of nitrate removal was determined. Materials and Methods This is a cross-sectional study conducted in laboratory scale. The UV spectrophotometer at a wavelength of maximum absorbance (220 nm was used to determine the nitrate concentration. The effect of pH, amount of chaff, temperature, and contact time were investigated. Results The result of this study revealed that chaff as an absorbent could remove nitrate from solutions, and the efficiency of adsorption increased as contact time increased from 5 to 30 minutes, amount of chaff increased from 1 to 3 g, temperature increased in a range of 300 - 400°C and the amount of pH decreased from 10 to 3. The maximum adsorption rate was around pH 3 (53.14%. Conclusions It was shown that the removal efficiency of nitrate was directly proportional to the amount of chaff, temperature, and contact time but inversely to the pH. This study showed that nitrate removal by chaff is a promising technique.

  4. Pb and Cd binding to natural freshwater biofilms developed at different pH: the important role of culture pH.

    Science.gov (United States)

    Hua, Xiuyi; Dong, Deming; Ding, Xiaoou; Yang, Fan; Jiang, Xu; Guo, Zhiyong

    2013-01-01

    The effects of solution pH on adsorption of trace metals to different types of natural aquatic solid materials have been studied extensively, but few studies have been carried out to investigate the effect of pH at which the solid materials were formed on the adsorption. The purpose of present study is to examine this effect of culture pH on metal adsorption to natural freshwater biofilms. The adsorption of Pb and Cd to biofilms which were developed at different culture pH values (ranging from 6.5 to 9.0) was measured at the same adsorption pH value (6.5). The culture pH had considerable effects on both composition and metal adsorption ability of the biofilms. Higher culture pH usually promoted the accumulation of organic material and Fe oxides in the biofilms. The culture pH also affected the quantity and species of algae in the biofilms. The adsorption of Pb and Cd to the biofilms generally increased with the increase of culture pH. This increase was minor at lower pH range and significant at higher pH range and was more remarkable for Cd adsorption than for Pb adsorption. The notable contribution of organic material to the adsorption at higher culture pH values was also observed. The profound impacts of culture pH on adsorption behavior of biofilms mainly resulted from the variation of total contents of the biofilm components and were also affected by the alteration of composition and properties of the components.

  5. Influence of soil solution cation composition on boron adsorption by soils

    Science.gov (United States)

    Boron (B) adsorption on five arid-zone soil samples from California was investigated as a function of solution pH (4-10) and cation composition (Na, Ca, or Mg). Boron adsorption increased with increasing solution pH, reached an adsorption maximum near pH 9, and decreased with further increases with...

  6. Monosilicate adsorption by ferrihydrite and goethite at pH 3-6

    DEFF Research Database (Denmark)

    Hansen, Hans Christian Bruun; Raben-Lange, B.; Raulund-Rasmussen, Karsten

    1994-01-01

    The constant capacitance model and the Elovich equation were combined in the following mathematical expression enabling calculation of the amount of silicic acid adsorbed by iron oxides as a function of the Si concentration, pH, soil:solution ratio, and reaction time: [GRAPHICS] K(a1) is the prot......The constant capacitance model and the Elovich equation were combined in the following mathematical expression enabling calculation of the amount of silicic acid adsorbed by iron oxides as a function of the Si concentration, pH, soil:solution ratio, and reaction time: [GRAPHICS] K(a1...

  7. Behavior of ellagitannins, gallic acid, and ellagic acid under alkaline conditions

    Science.gov (United States)

    Richard W. Hemingway; W.E. Hillis

    1971-01-01

    Examination of the rates of hydrolysis of different ellagitannins under conditions comparable with cold soda and alkaline-groundwood pulping processes showed that some ellagitannins are notably resistant to hydrolysis. The rate of hydrolysis was dependent upon the pH and tempemture of the solution and particularly upon the structure of the compound. Decarboxylation of...

  8. Large deviations for solutions to stochastic recurrence equations under Kesten's condition

    DEFF Research Database (Denmark)

    Buraczewski, Dariusz; Damek, Ewa; Mikosch, Thomas Valentin

    2013-01-01

    In this paper we prove large deviations results for partial sums constructed from the solution to a stochastic recurrence equation. We assume Kesten’s condition [17] under which the solution of the stochastic recurrence equation has a marginal distribution with power law tails, while the noise...... sequence of the equations can have light tails. The results of the paper are analogs of those obtained by A.V. and S.V. Nagaev [21, 22] in the case of partial sums of iid random variables. In the latter case, the large deviation probabilities of the partial sums are essentially determined by the largest...... step size of the partial sum. For the solution to a stochastic recurrence equation, the magnitude of the large deviation probabilities is again given by the tail of the maximum summand, but the exact asymptotic tail behavior is also influenced by clusters of extreme values, due to dependencies...

  9. Polarization characteristics of RTO anodes in the conditions of sodium chlorate preparation

    International Nuclear Information System (INIS)

    Ehberil', V.I.; Fedotova, N.S.; Novikov, E.A.

    1997-01-01

    By the method of polarization curves plotting in galvanostatic conditions in chloride-chlorate solutions of different compositions at different pH and temperatures it is shown that critical potential for oxide ruthenium-titanium anodes at current density less than 0.7 A/cm 2 is reached in solutions with NaCl concentration 50 g/l and low. The mechanism of potential transition to supercritical range is considered on the basis of ruthenium-water system analysis. (author)

  10. Fluoresence quenching of riboflavin in aqueous solution by methionin and cystein

    International Nuclear Information System (INIS)

    Droessler, P.; Holzer, W.; Penzkofer, A.; Hegemann, P.

    2003-01-01

    The fluorescence quantum distributions, fluorescence quantum yields, and fluorescence lifetimes of riboflavin in methanol, DMSO, water, and aqueous solutions of the sulphur atom containing amino acids methionin and cystein have been determined. In methanol, DMSO, and water (pH=4-8) only dynamic fluorescence reduction due to intersystem crossing and internal conversion is observed. In aqueous methionin solutions of pH=5.25-9 a pH independent static and dynamic fluorescence quenching occurs probably due to riboflavin anion-methionin cation pair formation. In aqueous cystein solutions (pH range from 4.15 to 9) the fluorescence quenching increases with rising pH due to cystein thiolate formation. The cystein thiol form present at low pH does not react with neutral riboflavin. Cystein thiolate present at high pH seems to react with neutral riboflavin causing riboflavin deprotonation (anion formation) by cystein thiolate reduction to the cystein thiol form

  11. FLEXIBLE PH SENSOR WITH POLYANILINE LAYER BASED ON IMPEDANCE MEASUREMENT

    OpenAIRE

    Chuang, Cheng-Hsin; Wu, Hsun-Pei; Chen, Cheng-Ho; Wu, Peng-Rong

    2012-01-01

    A flexible sensor with conducting polyaniline layer for detecting pH value based on the impedance measurement is fabricated and demonstrated in this study. The pH sensor consists of an interdigital electrode array on a flexible printed circuit and a thin-film polyaniline as the sensing layer. As the conductivity of polyaniline depends on the redox state, the impedance change of the polyaniline after it has reacted with different pH value solutions works as the sensing mechanism. In order to o...

  12. Analytical solution describing pesticide volatilization from soil affected by a change in surface condition.

    Science.gov (United States)

    Yates, S R

    2009-01-01

    An analytical solution describing the fate and transport of pesticides applied to soils has been developed. Two pesticide application methods can be simulated: point-source applications, such as idealized shank or a hot-gas injection method, and a more realistic shank-source application method that includes a vertical pesticide distribution in the soil domain due to a soil fracture caused by a shank. The solutions allow determination of the volatilization rate and other information that could be important for understanding fumigant movement and in the development of regulatory permitting conditions. The solutions can be used to characterize differences in emissions relative to changes in the soil degradation rate, surface barrier conditions, application depth, and soil packing. In some cases, simple algebraic expressions are provided that can be used to obtain the total emissions and total soil degradation. The solutions provide a consistent methodology for determining the total emissions and can be used with other information, such as field and laboratory experimental data, to support the development of fumigant regulations. The uses of the models are illustrated by several examples.

  13. Evaluating Nanoparticle Sensor Design for Intracellular pH Measurements

    DEFF Research Database (Denmark)

    Benjaminsen, Rikke Vicki; Sun, Honghao; Henriksen, Jonas Rosager

    2011-01-01

    Particle-based nanosensors have over the last decade been designed for optical fluorescent-based ratiometric measurements of pH in living cells. However, quantitative and time-resolved intracellular measurements of pH in endosomes and lysosomes using particle nanosensors is challenging...... and there is a need to improve measurement methodology. In the present paper, we have successfully carried out time resolved pH measurements in endosomes and lyosomes in living cells using nanoparticle sensors and show the importance of sensor choice for successful quantification. We have studied two nanoparticle...... quantification of pH is an unfortunate result when measuring pH too close to the limit of the sensitive range of the sensors. Triple-labeled nanosensors with a pH measurement range of 3.2-7.0, which was synthesized by adding two pH-sensitive fluorophores with different pKa to each sensor, seem to be a solution...

  14. An ultrasensitive method of real time pH monitoring with complementary metal oxide semiconductor image sensor.

    Science.gov (United States)

    Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2015-02-09

    CMOS sensors are becoming a powerful tool in the biological and chemical field. In this work, we introduce a new approach on quantifying various pH solutions with a CMOS image sensor. The CMOS image sensor based pH measurement produces high-accuracy analysis, making it a truly portable and user friendly system. pH indicator blended hydrogel matrix was fabricated as a thin film to the accurate color development. A distinct color change of red, green and blue (RGB) develops in the hydrogel film by applying various pH solutions (pH 1-14). The semi-quantitative pH evolution was acquired by visual read out. Further, CMOS image sensor absorbs the RGB color intensity of the film and hue value converted into digital numbers with the aid of an analog-to-digital converter (ADC) to determine the pH ranges of solutions. Chromaticity diagram and Euclidean distance represent the RGB color space and differentiation of pH ranges, respectively. This technique is applicable to sense the various toxic chemicals and chemical vapors by situ sensing. Ultimately, the entire approach can be integrated into smartphone and operable with the user friendly manner. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Sorption of Ni(II) on GMZ bentonite: effects of pH, ionic strength, foreign ions, humic acid and temperature.

    Science.gov (United States)

    Yang, Shitong; Li, Jiaxing; Lu, Yi; Chen, Yixue; Wang, Xiangke

    2009-09-01

    Bentonite has been widely studied in nuclear waste management because of its special physicochemical properties. In this work, the sorption of Ni(II) from aqueous solution onto GMZ bentonite as a function of contact time, pH, ionic strength, foreign ions, humic acid (HA) and temperature was investigated under ambient conditions. The results indicated that the pseudo-second-order rate equation simulated the kinetic sorption process well. The sorption of Ni(II) on GMZ bentonite was strongly dependent on pH and on ionic strength. At low pH, the sorption of Ni(II) was dominated by outer-sphere surface complexation and ion exchange with Na(+)/H(+) on GMZ bentonite surfaces, whereas inner-sphere surface complexation was the main sorption mechanism at high pH. A positive effect of HA on Ni(II) sorption was found at pH8. The Langmuir, Freundlich, and D-R models were used to simulate the sorption isotherms of Ni(II) at three different temperatures: 303.15, 318.15 and 333.15K. The thermodynamic parameters (DeltaH(0), DeltaS(0) and DeltaG(0)) of Ni(II) sorption on GMZ bentonite at the three different temperatures were calculated from the temperature-dependent sorption isotherms. The results indicated that the sorption process of Ni(II) on GMZ bentonite was endothermic and spontaneous. Experimental results indicate that GMZ bentonite is a suitable sorbent for pre-concentration and solidification of Ni(II) from large volume solutions.

  16. Sorption of Ni(II) on GMZ bentonite: Effects of pH, ionic strength, foreign ions, humic acid and temperature

    International Nuclear Information System (INIS)

    Yang Shitong; Li Jiaxing; Lu Yi; Chen Yixue; Wang Xiangke

    2009-01-01

    Bentonite has been widely studied in nuclear waste management because of its special physicochemical properties. In this work, the sorption of Ni(II) from aqueous solution onto GMZ bentonite as a function of contact time, pH, ionic strength, foreign ions, humic acid (HA) and temperature was investigated under ambient conditions. The results indicated that the pseudo-second-order rate equation simulated the kinetic sorption process well. The sorption of Ni(II) on GMZ bentonite was strongly dependent on pH and on ionic strength. At low pH, the sorption of Ni(II) was dominated by outer-sphere surface complexation and ion exchange with Na + /H + on GMZ bentonite surfaces, whereas inner-sphere surface complexation was the main sorption mechanism at high pH. A positive effect of HA on Ni(II) sorption was found at pH 8. The Langmuir, Freundlich, and D-R models were used to simulate the sorption isotherms of Ni(II) at three different temperatures: 303.15, 318.15 and 333.15 K. The thermodynamic parameters (ΔH 0 , ΔS 0 and ΔG 0 ) of Ni(II) sorption on GMZ bentonite at the three different temperatures were calculated from the temperature-dependent sorption isotherms. The results indicated that the sorption process of Ni(II) on GMZ bentonite was endothermic and spontaneous. Experimental results indicate that GMZ bentonite is a suitable sorbent for pre-concentration and solidification of Ni(II) from large volume solutions.

  17. Analytical solution for multi-species contaminant transport in finite media with time-varying boundary conditions

    Science.gov (United States)

    Most analytical solutions available for the equations governing the advective-dispersive transport of multiple solutes undergoing sequential first-order decay reactions have been developed for infinite or semi-infinite spatial domains and steady-state boundary conditions. In this work we present an ...

  18. Initial dissolution rate of a Japanese simulated high-level waste glass P0798 as a function of pH and temperature measured by using micro-channel flow-through test method

    International Nuclear Information System (INIS)

    Inagaki, Yaohiro; Makigaki, Hikaru; Idemitsu, Kazuya; Arima, Tatsumi; Mitsui, Sei-ichiro; Noshita, Kenji

    2012-01-01

    Aqueous dissolution tests were performed for a Japanese type of simulated high-level waste (HLW) glass P0798 by using a newly developed test method of micro-channel flow-through (MCFT) method, and the initial dissolution rate of glass matrix, r 0 , was measured as a function of solution pH (3-11) and temperature (25-90degC) precisely and consistently for systematic evaluation of the dissolution kinetics. The MCFT method using a micro-channel reactor with a coupon shaped glass specimen has the following features to provide precise and consistent data on the glass dissolution rate: (1) any controlled constant solution condition can be provided over the test duration; (2) the glass surface area actually reacting with solution can be determined accurately; and (3) direct and totally quantitative analyses of the reacted glass surface can be performed for confirming consistency of the test results. The present test results indicated that the r 0 shows a 'V-shaped' pH dependence with a minimum at around pH 6 at 25degC, but it changes to a 'U-shaped' one with a flat bottom at neutral pH at elevated temperatures of up to 90degC. The present results also indicated that the r 0 increases with temperature according to an Arrhenius law at any pH, and the apparent activation energy evaluated from Arrhenius relation increases with pH from 54 kJ/mol at pH 3 to 76 kJ/mol at pH 10, which suggests that the dissolution mechanism changes depending on pH. (author)

  19. pCO2 And pH regulation of cerebral blood flow

    Directory of Open Access Journals (Sweden)

    SeongHun eYoon

    2012-09-01

    Full Text Available CO2 Serves as one of the fundamental regulators of cerebral blood flow. It is widely considered that this regulation occurs through pCO2-driven changes in pH of the cerebral spinal fluid, with elevated and lowered pH causing direct relaxation and contraction of the smooth muscle, respectively. However, some findings also suggest that pCO2 acts independently of and/or in conjunction with altered pH. This action may be due to a direct effect of cerebral spinal fluid pCO2 on the smooth muscle as well as on the endothelium, nerves, and astrocytes. Findings may also point to an action of arterial pCO2 on the endothelium to regulate smooth muscle contractility. Thus, the effects of pH and pCO2 may be influenced by the absence/presence of different cell types in the various experimental preparations. Results may also be influenced by experimental parameters including myogenic tone as well as solutions containing significantly altered HCO3- concentrations, i.e., solutions routinely employed to differentiate the effects of pH from pCO2. In sum, it appears that pCO2, independently and in conjunction with pH, may regulate cerebral blood flow.

  20. Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH.

    Science.gov (United States)

    Galdino, Flávia E; Smith, Jamie P; Kwamou, Sophie I; Kampouris, Dimitrios K; Iniesta, Jesus; Smith, Graham C; Bonacin, Juliano A; Banks, Craig E

    2015-12-01

    A reagentless pH sensor based upon disposable and economical graphite screen-printed electrodes (GSPEs) is demonstrated for the first time. The voltammetric pH sensor utilizes GSPEs which are chemically pretreated to form surface immobilized oxygenated species that, when their redox behavior is monitored, give a Nernstian response over a large pH range (1-13). An excellent experimental correlation is observed between the voltammetric potential and pH over the entire pH range of 1-13 providing a simple approach with which to monitor solution pH. Such a linear response over this dynamic pH range is not usually expected but rather deviation from linearity is encountered at alkaline pH values; absence of this has previously been attributed to a change in the pKa value of surface immobilized groups from that of solution phase species. This non-deviation, which is observed here in the case of our facile produced reagentless pH sensor and also reported in the literature for pH sensitive compounds immobilized upon carbon electrodes/surfaces, where a linear response is observed over the entire pH range, is explained alternatively for the first time. The performance of the GSPE pH sensor is also directly compared with a glass pH probe and applied to the measurement of pH in "real" unbuffered samples where an excellent correlation between the two protocols is observed validating the proposed GSPE pH sensor.