WorldWideScience

Sample records for solution assistant dsa

  1. Real-world experimentation of distributed DSA network algorithms

    DEFF Research Database (Denmark)

    Tonelli, Oscar; Berardinelli, Gilberto; Tavares, Fernando Menezes Leitão

    2013-01-01

    such as a dynamic propagation environment, human presence impact and terminals mobility. This chapter focuses on the practical aspects related to the real world-experimentation with distributed DSA network algorithms over a testbed network. Challenges and solutions are extensively discussed, from the testbed design......The problem of spectrum scarcity in uncoordinated and/or heterogeneous wireless networks is the key aspect driving the research in the field of flexible management of frequency resources. In particular, distributed dynamic spectrum access (DSA) algorithms enable an efficient sharing...... to the setup of experiments. A practical example of experimentation process with a DSA algorithm is also provided....

  2. DSA for Secured Optical Communication

    International Nuclear Information System (INIS)

    Shojaei, A.A.; Amiri, I.S.

    2011-01-01

    Novel system of dark soliton array (DSA) for secured communication is proposed. The DSA are obtained by using a series micro ring resonators where the input wavelengths of λ 1 = 1516 nm, λ 2 = 1518 nm and λ 3 =1520 nm propagate inside the system and finally will be multiplexed. For security applications, the DSA can be tuned and amplified. The use of DSA for high capacity can be realized by using proposed secured system. (author)

  3. Gadolinium-DTPA (Magnevist) as a contrast medium for arterial DSA

    International Nuclear Information System (INIS)

    Schild, H.H.; Weber, W.; Boeck, E.; Mildenberger, P.; Strunk, H.; Dueber, C.; Grebe, P.; Schadmand-Fischer, S.; Thelen, M.

    1994-01-01

    16 DSA investigations using intra-arterial Gd-DTPA were performed on 12 patients. The contrast medium was administered either as a 0.5 molar gadolinium solution (commercially available) or diluted with distilled water to a 0.2 -0.4 molar gadolinium solution. The injection was made either by pressure injector or by hand. The aortic arch, abdominal aorta and pelvic and lower limb arteries were examined. 14 of the 16 procedures were diagnostically adequate, but compared with iodinated contrast materials, contrast was less marked. There were no cardiovascular, neurological or allergic side effects. Three patients suffered a feeling of heat and one patient had mild pain during the injection. Even large volumes rapidly injected (up to 20 ml/s of the commercially available solution) were well tolerated. DSA with intra-arterial Gd-DTPA seems to be a suitable alternative for vascular imaging if iodine-containing contrast materials are contraindicated. (orig.) [de

  4. Digital subtaction angiography (DSA) in renal-related conditions

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong

    1986-01-01

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  5. Digital subtaction angiography (DSA) in renal-related conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong [Soon Chun Hyang University College of Medicine, Asan (Korea, Republic of)

    1986-10-15

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  6. DSA in digital replantations

    International Nuclear Information System (INIS)

    Wang Liuhong; Chao Ming; Jiang Dingyao; Zhang Guangqiang; Wu Jianjun; Chen Xianyi; Li Bin; Sun Jihong

    2008-01-01

    Objective: To assess revascularization and vessel anastomosis in digital replantations with DSA. Methods: Twelve cases of digital replantations underwent digital subtract angiography during 2 to 4 days after fingers reattachment. The vessel anastomosis, hemodynamics, stenosis and discontinuation were investigated. The unobstructed and smooth anastomosis was suggested as early stage survival of the reattached fingers, the spasm and stenosis of the reattached vessels were considered as mild vascular crisis, and the discontinuation of hemodynamics were indicated as severe vascular crisis. Results: The total 27 vessels were clearly displayed on DSA. Of these vessels, 23 vessels were unobstructed and smooth, all digits were survived. Diagnosis coincidence of early stage survival was 100% (23/23). Two vessels were obstructed, which were testified having thrombus by operation research. The other 2 vessels were spasm, the digits were also survived ultimately by expectant treatment. All 4 abnormal vessel anatomosis were found by DSA. Conclusion: DSA is important modality in assessing revascularization and blood circulation for digital replantations, guiding in dealing with the vascular crisis, and in predicting early stage survival of the reattached digits. (authors)

  7. The comparison of aneurysmal necks measured on three dimensional reconstruction images of rotational DSA and those of traditional DSA

    International Nuclear Information System (INIS)

    Wu Chunhong; Chen Zuoquan; Gu Binxian; Zhang Guiyun

    2006-01-01

    Objective: To evaluate the value of three dimensional reconstruction images of rotational DSA on measuring aneurysmal necks and make a comparison with traditional DSA so as to provide more abundant and accurate information for the embolization of aneurysm. Methods: A comparison was made between the measurement of aneurismal necks from 14 cases with traditional DSA examination and a measurement made on three dimensional reconstruction images of the same patients. Results: There was a difference shown in the measurement of the aneurysmal necks between three dimensional reconstruction images of rotational DSA and those of traditional DSA, outcoming with more angles and data on three dimensional reconstruction images. Conclusions: There are more angles of aneurysmal neck can be shown on rotational 3D DSA especially for the demonstration of the largest aneurysmal neck with a directional value for the intervention. (authors)

  8. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  9. Clinical usefulness of stereoscopic DSA

    International Nuclear Information System (INIS)

    Bussaka, Hiromasa; Takahashi, Mutsumasa; Miyawaki, Masayuki; Korogi, Yukinori; Yamashita, Yasuyuki; Izunaga, Hiroshi; Nakashima, Koki; Yoshizumi, Kazuhiro

    1988-01-01

    Digital subtraction angiography (DSA) is widely used as a screening examination for vascular diseases, but it has several disadvantages, one of which is overlapping of the vessels. To overcome this disadvantage, stereoscopic technique is applied to our DSA equipment. Stereoscopic DSA is obtained by alternate exposures from twin focal spots of an x-ray tube without additional contrast medium or radiation exposures. Stereoscopic intravenous DSA was performed 223 times, and was useful in 157 times (70.4 %) for the identification and stereoscopic observation of the abdominal and pelvic vessels. Thirty-seven intra-arterial DSAs were performed stereoscopically for cranial, abdominal and pelvic angiograms, and effective studies were obtained in 30 DSAs (81.1 %) with demonstration of tumor stains and displacement of the vessels. It is necessary to use adequate compensation filters for the good stereoscopic DSAs, especially for the cervical and thoracic DSAs. (author)

  10. DSA patterning options for logics and memory applications

    Science.gov (United States)

    Liu, Chi-Chun; Franke, Elliott; Mignot, Yann; LeFevre, Scott; Sieg, Stuart; Chi, Cheng; Meli, Luciana; Parnell, Doni; Schmidt, Kristin; Sanchez, Martha; Singh, Lovejeet; Furukawa, Tsuyoshi; Seshadri, Indira; De Silva, Ekmini Anuja; Tsai, Hsinyu; Lai, Kafai; Truong, Hoa; Farrell, Richard; Bruce, Robert; Somervell, Mark; Sanders, Daniel; Felix, Nelson; Arnold, John; Hetzer, David; Ko, Akiteru; Metz, Andrew; Colburn, Matthew; Corliss, Daniel

    2017-03-01

    The progress of three potential DSA applications, i.e. fin formation, via shrink, and pillars, were reviewed in this paper. For fin application, in addition to pattern quality, other important considerations such as customization and design flexibility were discussed. An electrical viachain study verified the DSA rectification effect on CD distribution by showing a tighter current distribution compared to that derived from the guiding pattern direct transfer without using DSA. Finally, a structural demonstration of pillar formation highlights the importance of pattern transfer in retaining both the CD and local CDU improvement from DSA. The learning from these three case studies can provide perspectives that may not have been considered thoroughly in the past. By including more important elements during DSA process development, the DSA maturity can be further advanced and move DSA closer to HVM adoption.

  11. Incorporating DSA in multipatterning semiconductor manufacturing technologies

    Science.gov (United States)

    Badr, Yasmine; Torres, J. A.; Ma, Yuansheng; Mitra, Joydeep; Gupta, Puneet

    2015-03-01

    Multi-patterning (MP) is the process of record for many sub-10nm process technologies. The drive to higher densities has required the use of double and triple patterning for several layers; but this increases the cost of the new processes especially for low volume products in which the mask set is a large percentage of the total cost. For that reason there has been a strong incentive to develop technologies like Directed Self Assembly (DSA), EUV or E-beam direct write to reduce the total number of masks needed in a new technology node. Because of the nature of the technology, DSA cylinder graphoepitaxy only allows single-size holes in a single patterning approach. However, by integrating DSA and MP into a hybrid DSA-MP process, it is possible to come up with decomposition approaches that increase the design flexibility, allowing different size holes or bar structures by independently changing the process for every patterning step. A simple approach to integrate multi-patterning with DSA is to perform DSA grouping and MP decomposition in sequence whether it is: grouping-then-decomposition or decomposition-then-grouping; and each of the two sequences has its pros and cons. However, this paper describes why these intuitive approaches do not produce results of acceptable quality from the point of view of design compliance and we highlight the need for custom DSA-aware MP algorithms.

  12. N7 logic via patterning using templated DSA: implementation aspects

    Science.gov (United States)

    Bekaert, J.; Doise, J.; Gronheid, R.; Ryckaert, J.; Vandenberghe, G.; Fenger, G.; Her, Y. J.; Cao, Y.

    2015-07-01

    In recent years, major advancements have been made in the directed self-assembly (DSA) of block copolymers (BCP). Insertion of DSA for IC fabrication is seriously considered for the 7 nm node. At this node the DSA technology could alleviate costs for multiple patterning and limit the number of masks that would be required per layer. At imec, multiple approaches for inserting DSA into the 7 nm node are considered. One of the most straightforward approaches for implementation would be for via patterning through templated DSA; a grapho-epitaxy flow using cylindrical phase BCP material resulting in contact hole multiplication within a litho-defined pre-pattern. To be implemented for 7 nm node via patterning, not only the appropriate process flow needs to be available, but also DSA-aware mask decomposition is required. In this paper, several aspects of the imec approach for implementing templated DSA will be discussed, including experimental demonstration of density effect mitigation, DSA hole pattern transfer and double DSA patterning, creation of a compact DSA model. Using an actual 7 nm node logic layout, we derive DSA-friendly design rules in a logical way from a lithographer's view point. A concrete assessment is provided on how DSA-friendly design could potentially reduce the number of Via masks for a place-and-routed N7 logic pattern.

  13. 'Table step-shift DSA' for peripheral angiography

    International Nuclear Information System (INIS)

    Kojima, Kanji; Seo, Hiroyuki; Kawase, Yoshirou; Hino, Ichirou; Satou, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Tamai, Toyosato; Tanabe, Masatada

    1987-01-01

    We developed a new technique of digital subtraction angiography (DSA) for peripheral angiography, which make it possible to obtain DSA images of two contiguous positions with a single injection of contrast material. It is made by the combination with DSA system (Toshiba Digiformer X-03A) and the angio-table with step-shift function (Toshiba CAT-FX), which is widely used in the conventional angiography for pelvis and lower extrimities. When DSA image of the first position is sufficiently demonstrated, the table is semi-automatically translated to the second position by the switching of the operator, observing TV-monitor. The images are stored into the digital image disc. DSA image of the second position can be given by the remasking method. We examined 40 times ''table step-shift DSA'' on 18 patients, which consist of 19 IVDSA with central injection and 21 IADSA for abdomen and lower leg. In 90 % and 72.5 % of images the procedure was diagnostic for the 1st and 2nd position respectively. The causes of nondiagnostic image were mostly from the prolonged blood flow and its difference in both sides. With this technique we could reduce the contrast material load and the time consumption of the examination. (author)

  14. Improvement of DSA, reduction of acquisition images and suppression of halation

    International Nuclear Information System (INIS)

    Yamada, Kinichi; Kaga, Yuji; Eguchi, Yoichi; Kinai, Shigeo; Asahina, Hiroshi; Fujita, Hitoshi; Ogura, Ichiro; Yasuhara, Hiroshi.

    1991-01-01

    Recently, digital subtraction angiography (DSA) is seeing widespread use. Especially, intraarterial DSA (IA-DSA) makes good use of interventional radiology. However, we know that the skin dose for DSA is so much larger than general angiography, and halations often appearing on DSA images. In this report, we show two improvements of DSA. First, the skin dose for DSA is successfully decreased to one-sixth compared with the late DSA of cerebral artery by a reduction in acquisition images. Secondly, we are doing well in suppressing halation by exchanging the control point of automatic exposure control (AEC) from one-half to one-fourth. (author)

  15. Three-dimensional image reconstruction from stereo DSA

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Umehara, Takayoshi; Yamada, Eiji; Inaba, Tomohiro; Itou, Hiroshi

    1999-01-01

    The technique of interventional radiology has spread rapidly in recent years, and three-dimensional information from blood vessel images is being sought to enhance examinations. Stereo digital subtraction angiography (DSA) and rotational DSA were developed for that purpose. However, it is difficult with stereo DSA to observe the image pair during examination and to obtain positional information on blood vessels. Further, the exposure dose is increased in rotational DSA when many mask images need to be collected, and the patient is required to hold his or her breath for a long duration. We therefore devised a technique to construct three-dimensional blood vessel images by employing geometrical information extracted from stereo DSA images using the right and left images. We used a judgment method based on the correlation coefficient, although we had to extract an equal blood vessel from the right and left images to determine the three-dimensional coordinates of the blood vessel. The reconstructed three-dimensional blood vessels were projected from various angles, again by using a virtual focus, and new images were created. These image groups were displayed as rotational images by the animation display function incorporated in the DSA device. This system can observe blood vessel images of the same phase at a free angle, although the image quality is inferior to that of rotational DSA. In addition, because collection of the mask images is reduced, exposure dose can be decreased. Further, the system offers enhanced safety because no mechanical movement of the imaging system is involved. (author)

  16. Dynamic study of DSA by video-densitometry

    International Nuclear Information System (INIS)

    Imamura, Keiko; Tsukamoto, Hiroshi; Ashida, Hiroshi; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    A system was developed for the dynamic study of DSA by video-densitometric technique. As subtraction images are stored to VTR in our DSA examinations, a frame counter was designed to select images on VTR at an arbitrary interval. ROI setting and video-densitometry were performed using a TV image processor and its host computer. Images were sampled at the rate of 3 frames per second, and clear time-density curves were obtained from brain DSA examinations. Although it takes about 30 minutes to analyse one examination, it is also possible to analyse previous data stored on VTR. For DSA systems having no additional digital storage unit, this method will be helpful. Reduction in image quality through VTR storage had no problem in video-densitometry. Phantom studies have been made concerning the temporal variation of the image brightness during the 20 second-exposure and also the effect of the subjects thickness on the contrast. Filtering for low-grade averaging is preferable for dynamic studies. (author)

  17. Development of simple DSA equipment and experience of its using

    International Nuclear Information System (INIS)

    Yoshino, Fumiki; Matsuo, Michimasa.

    1984-01-01

    We manufactured a cheap and portable simple DSA equipment, consisting of an ordinary X-ray system and a microcomputer which is the hardware exclusively used for real-time processing. As the result of the basic clinical examination by simple DSA equipment, we found it effective on the follow-up study of diseases such as the arteriosclerosis obliterans. We performed the intra-arterial DSA with a catheter which was small in the inside diameter, to reduce its aggression, and at the same time we are trying its application to the functional image. In the future, it will show us the possibility of the routine screening examination at an out-patients' department. Compared with DSA equipment sold in the market, our simple DSA equipment is good enough to make diagnostic images in spite of the limited capacity of TV system. Moreover, our DSA equipment is cheap and portable, and is very effective for the follow-up study of diseases such as the arteriosclerosis obliterans. So we can say that simple DSA equipment is of excellent clinical value. (author)

  18. Comparative evaluation of cerebral aneurysms with selective arterially enhanced CT and DSA

    International Nuclear Information System (INIS)

    Vanderschelden, P.; Flandroy, P.; Dondelinger, R.F.; Martin, D.; Lenelle, J.

    1998-01-01

    The purpose of our study was to compare selective arterially enhanced spiral computed tomographs (ACT) with digital subtraction angiographies (DSA) in the presurgical assessment of cerebral aneurysms. A total of 24 aneurysms in 18 patients were explored in a prospective study by ACT and DSA, using an interactive combined CT-angiography suite. Dimensions of the aneurysm, its relation to the parent vessel, and the aneurysmal index were defined on DSA and on surface-shaded display of 3D reformatted images obtained from ACT. Results were correlated with surgical findings. Three aneurysms suspected on DSA were not confirmed by ACT. One fusiform aneurysm suspected on DSA corresponded to a sacciform aneurysm on ACT. Surgical findings confirmed 20 sacciform aneurysms. The aneurysmal index could be measured in all 20 cases of sacciform aneurysms on ACT and could not be determined with confidence in 55 % of the cases on DSA. DSA and ACT gave identical results in 35 % of cases. In 10 %, the index measured by ACT was superior to that determined by DSA for aneurysms which had a diameter of less than 3 mm. In conclusion, the combination of DSA and ACT improved the results of DSA alone. ACT is a reliable method to measure the aneurysmal index in aneurysms with a diameter superior to 3 mm. (orig.)

  19. Digital substraction angiography (DSA) in a universal radiodiagnostic room with a novel multi-pulse high-frequency generator

    International Nuclear Information System (INIS)

    Ellegast, H.H.; Kloss, R.; Mayr, H.; Ammann, E.; Kuehnel, W.; Siemens A.G., Erlangen

    1985-01-01

    Application of digital subtraction angiography in a universal radiodiagnostic room can be implemented rapidly and reliably. The number of examinations could be increased without negative effects to conventional operations in this room. At optimum radiation hygiene and high-degree operational safety, the multipulse high-frequency generator with its DSA parameter automatic system guarantees a reproducibly good image quality equalling that of a special DSA facility. In this way, the examination room constitutes an economic solution for small-sized hospitals without any special angiography room, too. (orig.) [de

  20. [Design and development of the DSA digital subtraction workstation].

    Science.gov (United States)

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  1. Preoperative imaging in 78 living kidney donors using CE-MRA and DSA; Donor-Evaluation vor Lebendnierenspende: Vergleich von CE-MRA und DSA an 78 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, U.; Taupitz, M.; Hamm, B.; Kroencke, T.J. [Inst. fuer Radiologie, Charite - Universitaetsmedizin Berlin (Germany); Kluener, C. [Inst. fuer Radiologie und Neuroradiologie, Evangelisches Krankenhaus Oldenburg (Germany); Giessing, M.; Schoenberger, B. [Urologische Klinik und Poliklinik, Charite - Universitaetsmedizin Berlin (Germany)

    2008-01-15

    Purpose: to evaluate contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) in comparison with the intraoperative findings in living kidney donors. Materials and methods: a total of 156 kidneys in 78 potential kidney donors were prospectively examined using CE-MRA (0.2 mmol Gd/kg, voxel size 1.3 x 0.8 x 2.0) and DSA. Two experienced radiologists assessed the images in consensus regarding the renal vascular anatomy and variants. The results for the 67 candidates accepted for donation were compared to the intraoperative findings. In the other kidneys not accepted for donor nephrectomy, MRA and DSA were compared with each other. Results: nineteen arterial variants were identified intraoperatively, of which 11 (58%) were also detected by preoperative CE-MRA and 10 (53%) by preoperative DSA. Of the 10 venous variants found intraoperatively, CE-MRA detected 8 (80%) and DSA 3 (30%). The agreement (kappa test) between MRI and DSA for all 156 evaluated kidneys was 0.7 for arterial variants (McNemar p = 0.12) and 0.3 for venous variants (McNemar p = 0.01). The preoperative choice of kidney (right or left) made on the basis of the renal vascular anatomy seen on CE-MRA and DSA differed in 22% of the 78 potential donors (McNemar P = 0.3). (orig.)

  2. The DSA findings and interventional therapy of hepatic alveolar echinococcus

    International Nuclear Information System (INIS)

    Ren Weixin; Xiao Xiangsheng; Chen Peng; Ma Jun

    2004-01-01

    Objective: To analyse the DSA findings of hepatic alveolar echinococcus (HAE) and evaluate the feasibility of the interventional therapy. Methods: Eight patients with HAE were all examined by DSA, CT and lab test. Three of them were performed the transcatheter arterial embolization by iodized oil. All of them were confirmed by surgical operation and followed-up for three months. Results: The DSA findings of HAE included hepatic arterial curling and enlargement with hypertrophied circled encircling as typical 'handed ball'. Eight cases presented the ring stain during the capillary stage. After embolization, the retention of iodized oil was revealed by DSA in 3 cases. CT three months later showed fine iodized oil retention and the enlarged necrosis. Ischemic necrosis around the lesion and the cut margins were clearly seen in operation biopsy. Conclusions: HAE possesses special DSA findings and interventional therapy is a new therapeutic method of choice. (authors)

  3. Intra-arterial DSA of the mesenterico-spleno-portal vessels

    Energy Technology Data Exchange (ETDEWEB)

    Busch, H P; Hoevels, J; Prager, P; Strauss, L

    1985-01-01

    The article examines the application of i.a. DSA for the visualization of mesenterico-spleno-portal veins. Indications are portal hypertension and resectability assessment in pancreas tumours. Compared with conventional angiography, i.a. DSA yields a better demonstration of the splanchnic veins in about 50% of the cases. Advantages of i.a. DSA involve good-quality vessel visualization along with a reduction of examination time and cost. Its disadvantages are low-grade local resolution and strong dependence of picture quality on the patients' cooperation.

  4. In vitro and clinical evaluation of DSA in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Rees, C.R.; Palmaz, J.C.; Alvarado, R.; Tyrrel, R.; Ciaravino, V.; Register, T.; Reuter, S.R.

    1987-01-01

    In an in vitro model of gastrointestinal (GI) bleeding, digital subtraction angiography (DSA) was found to be more accurate, more sensitive, and equally specific in the detection of extravasation compared to conventional screen-film angiography /sub chi//sup 2/, P < .05), DSA was used in the diagnosis and/or therapeutic management of 35 patients with GI bleeding (in the upper tract in 30, in the lower tract in five). When DSA results were negative (13 cases), results of conventional angiography were also negative. Upper GI bleeding episodes could be managed solely with DSA, which shortened examination times by 20% - 35%. The usefulness of DSA in lower GI bleeding was limited in the authors' series by a 9-inch image intensifier and misregistration caused by bowel motion

  5. Pre-transplant soluble CD30 in combination with total DSA but not pre-transplant C1q-DSA predicts antibody-mediated graft loss in presensitized high-risk kidney transplant recipients.

    Science.gov (United States)

    Schaefer, S M; Süsal, C; Opelz, G; Döhler, B; Becker, L E; Klein, K; Sickmüller, S; Waldherr, R; Macher-Goeppinger, S; Schemmer, P; Beimler, J; Zeier, M; Morath, C

    2016-02-01

    Presensitized kidney transplant recipients are at high-risk for early antibody-mediated rejection. We studied the impact of pre- and post-transplant donor-specific human leukocyte antigen (HLA) antibodies (DSA) and T-cell-activation on the occurrence of antibody-mediated rejection episodes (AMR) and graft loss (AMR-GL) in a unique cohort of 80 desensitized high-risk kidney transplant recipients. Patients with pre-transplant DSA demonstrated more AMR episodes than patients without DSA, but did not show a significantly increased rate of AMR-GL. The rates of AMR and AMR-GL were not significantly increased in patients with complement split product (C1q)-binding pre-transplant DSA. Pre-transplant C1q-DSA became undetectable post-transplant in 11 of 13 (85%) patients; 2 (18%) of these 11 patients showed AMR but no AMR-GL. In contrast, the post-transplant presence of C1q-DSA was associated with significantly higher rates of AMR (86 vs 33 vs 0%; P transplant DSA without C1q-binding or the absence of DSA. Patients with both pre-transplant DSA and evidence of pre-transplant T-cell-activation as indicated by soluble CD30-positivity showed a significantly increased risk for AMR-GL [HR = 11.1, 95% confidence interval (CI) = 1.68-73.4; log-rank P = 0.013]. In these high-risk patients, AMR-GL was associated with total DSA in combination with T-cell-activation pre-transplant, and de novo or persistent C1q-binding DSA post-transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Comparative analysis of CT and DSA in traumatic splenic salvage

    International Nuclear Information System (INIS)

    Liu Tie; Mao Xinfeng; Pan Feng

    2005-01-01

    Objective: To explore the better diagnostic method for acute splenic artery injury through comparative analysis of CT and DSA. Methods: Fifty-seven patients with acute splenic injury were examined by CT and DSA, treated with splenic arterial embolization and then undertook follow up. Results: CT examination possessed higher sensitivity and accuracy than DSA in demonstrating splenic parenchymal laceration, intrasplenic hematoma, subcapsular hematoma, rupture of splenic capsule and combined injury of intra-abdominal organs, especially in localizing splenic laceration. And there was a high significant difference statistically between the two kinds of examination (χ 2 =10.71, P 2 =12.57, P<0.005). Conclusions: CT and DSA are complementary in the diagnosis of splenic injury. After CT confirmation of splenic injury and the patient vital signs being stable, DSA should be referred to as soon as possible for further detail information as well as for possible interventional embolization and reduction of surgical complications. (authors)

  7. Fundamental study of DSA images using gadolinium contrast agent

    International Nuclear Information System (INIS)

    Nagashima, Hiroyuki; Shiraishi, Akihisa; Igarashi, Hitoshi; Sakamoto, Hajime; Sano, Yoshitomo

    2002-01-01

    Most contrast agents used in digital subtraction angiography (DSA) are non-ionic iodinated contrast agents, which can cause severe side effects in patients with contraindications for iodine or allergic reactions to iodine. Therefore, DSA examinations using carbon dioxide gas or examinations done by magnetic resonance imaging (MRI) and ultrasound (US) were carried out in these patients. However, none of these examinations provided mages as clear as those of DSA with an iodinated contrast agent. We experienced DSA examination using a gadolinium contrast agent in a patient contraindicated for iodine. The patient had undergone MRI examination with a gadolinium contrast agent previously without side effects. The characteristics of gadolinium and the iodinated contrast agent were compared, and the DSA images obtained clinically using these media were also evaluated. The signal-to-noise (SN) ratio of the gadolinium contrast agent was the highest at tube voltages of 70 to 80 kilovolts and improved slightly when the image intensifier (I.I.) entrance dose was greater than 300 μR (77.4 nC/kg). The dilution ratios of five iodinated contrast agents showed the same S/N value as the undiluted gadolinium contrast agent. Clinically, the images obtained showed a slight decrease in contrast but provided the data necessary to make a diagnosis and made it possible to obtain interventional radiology (IVR) without any side effects. DSA examinations using a gadolinium contrast agent have some benefit with low risk and are thought to be useful for patients contraindicated for iodine. (author)

  8. Peripheral occlusive vascular disease: Diagnostic performance of MRA and DSA

    International Nuclear Information System (INIS)

    Krug, B.; Kugel, H.; Harnischmacher, U.; Heindel, W.; Altenburg, A.; Fischbach, R.; Schmidt, R.

    1995-01-01

    In 59 patients with arterial flow disturbances 2-D inflow sequence of the abdominal and lower leg arteries were prospectively obtained on a 1.5 T MR-imager and were compared with additional DSA examinations. Supplementary Phase Contraste RSE ('Rapid Sequential Excitation') sequences were carried out in 29 patients. MRA and DSA angiograms were evaluated in random order by 4 readers using a questionnaire. The assessment of image quality were evaluated by variance analysis. Diagnostic performance of MRA and DSA was assessed by comparison of the readers' diagnostic assessments with reference diagnoses established by a radiologist and a vascular surgeon with full knowledge of all data concerning a patient. Image quality of inflow MRA was considered inferior to i.a. DSA (p [de

  9. Coregistration of three dimensional DSA and MR angiography in neuronavigation for neurosurgery

    International Nuclear Information System (INIS)

    Tang Weijun; Jin Yi; Li Ke; Feng Xiaoyuan; Hong Yong

    2007-01-01

    Objective: To assess the accuracy of neuronavigation of 3D DSA and to evaluate the feasibility of 3D DSA neuronavigational neurosurgery through the coregistration of 3D DSA and MRI(A). Methods: A Peg-Board Phantom was used in our study. The phantom consisted of 32 rods which were used for target localization; the height and the location of the rods were in normal distribution. For 3D DSA (Infinix NS/VC, Toshiba), the raw data was reconstructed to 3D images on the DSA workstation, and transferred to a online PC workstation where it was converted to standard 2D DICOM image data using WFU DICOM T oolkit software. For MRI (A), the phantom was scanned with FSPGR sequence on the MRI scanner (GE Signa VH/i 3.0 T), and the DICOM images were also transferred to the online PC workstation. Using the software 3D Slicer registration was performed on the PC workstation by using the location and shape of the rods in the phantom. The localization error of the rods was measured in image space as the Euclidean distance between targets defined in image space and those detected in the physical space. Paired t test was used to evaluate the difference between the accuracy of neuronaviagtion of 3D DSA and that of MRI(A). Results: Through the coregistration of the rods in the phantom from different modality, all the images were better coregistrated. The mean localization error was (0.38 ± 0.24)mm (3D DSA) and (0.31 ± 0.12)mm[MRI(A)]. There was no significant statistical difference between the accuracy of neuronavigation of 3D DSA and MRI(A) (t=-0.601, P=0.55). Conclusion: 3D DSA images can be used in the neuronavigation system through the coregistration of 3D DSA and MRI(A). (authors)

  10. Chronic thromboembolic pulmonary hypertension: diagnostic impact of multislice-CT and selective pulmonary-DSA

    International Nuclear Information System (INIS)

    Pitton, M.B.; Kemmerich, G.; Herber, S.; Schweden, F.; Thelen, M.; Mayer, E.

    2002-01-01

    Purpose: To evaluate the diagnostic impact of multislice-CT and selective pulmonary DSA in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: 994 vessel segments of 14 consecutive patients with CTEPH were investigated with multislice-CT (slice thickness 3 mm, collimation 2.5 mm, reconstruction intervall 2 mm) and selective pulmonary DSA posterior-anterior, 45 oblique, and lateral projection. Analysis was performed by 2 investigators independently for CT and DSA. Diagnostic criteria were occlusions and non-occlusive changes like webs and bands, irregularities of the vessel wall, diameter reduction and thromboembolic depositions at different levels from central pulmonary arteries to subsegmental arteries. Reference diagnosis was made by synopsis of CT and DSA by consensus. Results: Concerning patency CT and DSA showed concordant findings overall in 88.9%, 92.9% for segmental arteries and 85.4% for subsegmental arteries. Concerning any thromboembolic changes, multislice-CT was significantly inferior to selective DSA (concordance 67.0% overall, 70.4% for segments and 63.6% for subsegments). Non-occlusive changes of the vessels were significantly underdiagnosed by CT (concordance of CT versus DSA: 23.1%). Conclusion: Multislice-CT and selective pulmonary DSA are equivalent for diagnosis of vessel occlusions at the level of segmental and subsegmental arteries. However, for visualisation of the non-occlusive thromboembolic changes of the vessel wall selective pulmonary DSA is still superior compared to multislice-CT. Multislice-CT and selective pulmonary DSA are complementary tools for diagnosis and treatment planning of chronic thromboembolic pulmonary hypertension (CTEPH). (orig.) [de

  11. DSA diagnosis and interventional management of postoperative bleeding

    International Nuclear Information System (INIS)

    Li Yuwei; Zhang Fuqiang; Li Yunhui; Yuan Liang; Si Guangyan; Liu Lili

    2009-01-01

    Objective: To discuss the clinical application of DSA and interventional management in diagnosing and treating the bleeding after surgery. Methods: The clinical data and the interventional management of 14 patients with DSA-proved postoperative bleeding, encountered during the period of Aug. 2005-Jan. 2008, were retrospectively analyzed. The surgeries included subtotal gastrectomy (n=4), pancreatoduodenectomy (n=3), cesarean section (n=2), nephrolithotomy (n=3), heminephrectomy (n=1), internal hemorrhoidectomy (n=1). Results: Seventeen arterial bleeding sites were demonstrated, including gastroduodenal (n=2), left gastric (n=4), phrenic (n=1), short gastric (n=1), superior mesenteric (n=2), renal (n=4), uterine (n=2) and internal pudendal (n=1) artery. The diagnosis was confirmed with DSA in all 14 patients, of which embolization was successfully carried out in 13 in one session (92.8%). The remaining one case had to be operated again to stop the bleeding because of the failure of the superselective catheterization. No serious complications, such as organ necrosis or visceral dysfunction, occurred. Conclusion: As a safe, minimally-invasive and effective technique, DSA and interventional management are very helpful in diagnosing and treating the bleeding after surgery. (authors)

  12. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  13. The analysis of cerebro-vascular circulation time using digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Han, D. G.; Kim, D. H.; Lee, H. K.; Kwon, K. H.; Kim, K. J.

    1986-01-01

    We analyzed the cerebral arterio-venous circulation time of 141 cases of cranial DSA in 136 patients, for the assessment of cerebral circulatory dynamics. IV-DSA was 111 cases, IA-DSA 30 cases. The results were as follows: 1. There was no significant difference in arterio-venous circulation time between IA-DSA and IV-DSA, if the disease pattern was not considered (P > 0.1). 2. Prolongation of arterio-venous circulation time was noted in the cases of cerebral (cerebellar) hemorrhage, subarachnoid hemorrhage, intracranial hematoma, brain abscess, acute stage of cerebra-vascular occlusive disease, acute stage of postoperative follow up, and acute stage of cerebral contusion (p > 0.05). 3. Compared the chronic stage of cerebra-vascular occlusive disease, postoperative follow up, and cerebral contusion with acute stage, significant decrement of arterio-venous circulation time was resulted (p > 0.05). 4. DSA was a useful modality for the assessment of circulatory dynamics, including measurement of arterio-venous circulation time.

  14. Evaluation of the cerebral vasculature by intrarterial DSA - with emphasis on in vivo resolution

    International Nuclear Information System (INIS)

    Takahashi, M.; Bussaka, H.; Nakagawa, N.

    1984-01-01

    Comparative study was performed between IA DSA and stereoscopic magnification angiography in relation to small vessel resolution, image quality of the vessels and image quality of various pathologic lesions. The vessels of various diameters accurately measured by stereoscopic magnification angiography, were localized on IA DSA and their resolution was carefully assessed. The vessels more than 1 mm in diameter were equally visualized on IA DSA and conventional angiography. The vessels between 1 mm and 0.5 mm showed fair resolution on IA DSA, whereas IA DSA did not resolve the vessels smaller than 0.5 mm in diameter to good advantage. In addition, image quality of the vessels on IA DSA was compared with the conventional methods. Cerebral gyrus, venous sinuses, and intracerebral veins are often shown better on DSA. The small vessels such as lenticulostriate, small cortical, thalamoperforate and meningohypophyseal arteries were not defined on DSA. Equal or better image quality was obtained in more than 85% of cases with pathologic lesions. Examinations were performed faster with lower cost and lower complication rate. Information provided by DSA was often sufficient for managements of patients. Combined use of DSA and conventional angiography will improve diagnostic accuracy and decrease the complication rate. (orig.)

  15. The possible critical role of T-cell help in DSA-mediated graft loss.

    Science.gov (United States)

    Süsal, Caner; Slavcev, Antonij; Pham, Lien; Zeier, Martin; Morath, Christian

    2018-06-01

    In this review, we discuss a possible central role of T-cell help in severe forms of graft damage mediated by donor-specific HLA antibodies (DSA). Some kidney transplant recipients with pretransplant DSA show a high graft failure rate, whereas in other patients DSA do not harm the transplanted kidney and in most cases, disappear shortly after transplantation. Analyzing 80 desensitized highly immunized kidney transplant recipients and another multicenter cohort of 385 patients with pretransplant HLA antibodies, we reported recently that an ongoing T-cell help from an activated immune system, as measured by an increased level of soluble CD30 in serum, might be necessary for the DSA to exert a deleterious effect. Patients positive for both pretransplant DSA and sCD30 appear to require special measures, such as the elimination of DSA from the circulation, potent immunosuppression, good HLA-matching, and intense post-transplant monitoring, whereas exclusion of DSA-positive patients from transplantation in the absence of high sCD30 may not be justified in all cases, even if the pretransplant DSA are strong and complement-activating. © 2018 Steunstichting ESOT.

  16. The DSA appearance and its clinical significance in renovascular hypertension

    International Nuclear Information System (INIS)

    Su Guoqiang; Zhu Yaoqing; Gao Chongjing

    2000-01-01

    Objective: To discuss the DSA appearance of renovascular hypertension and the feasible necessity of dilatation of stenotic renal artery. Methods: DSA data of bilateral renal arteries of 21 patients, with suspected renovascular hypertension were analyzed. Results: Among those 21 patients, 11 did have stenoses in renal artery or its branches. Balloon dilatation were performed successfully in 6 patients. The successful rate was 54.55%. Conclusions: DSA is the preferable method for the diagnosis of renovascular hypertension, and offers reliable clinical data for interventional therapy

  17. Incidence and Factors Associated with De Novo DSA After BK Viremia in Renal Transplant Recipients.

    Science.gov (United States)

    Patel, Samir J; Kuten, Samantha A; Knight, Richard J; Graviss, Edward A; Nguyen, Duc; Gaber, A Osama

    2016-01-01

    BK polyomavirus infection and de novo donor-human leukocyte antigen (HLA) specific antibodies (dnDSA) are two well-known and distinct complications occurring after kidney transplantation. Recent literature suggests an association between the two events. This study aims to examine the relationship between BK viremia (BKV) and dnDSA and to identify potential risk factors for dnDSA following BKV in kidney transplant recipients. A retrospective review of 1019 recipients from Houston Methodist Hospital was conducted. All patients underwent routine screening for BKV and dnDSA. Median follow-up was 44 months. BKV was detected in 186 (18%) patients at a median of 107 (82-205) days post-transplant. dnDSA occurred in 283 (28%) patients at a median of 272 (62-575) days post-transplant. Of the 69 dnDSA-positive/BKV-positive patients, dnDSA detection occurred after BKV onset in 46 patients. Thus, 46 (28%) previously DSA-negative patients later became dnDSA-positive following BKV, not significantly different from the rate seen in BKV-negative patients (26%; p=0.5). Median time to DSA detection following BKV onset was 232 days (interquartile range, 119-460) post-BKV detection. Multivariate analysis revealed a greater number of HLA mismatches and viral clearance as risk factors for development of dnDSA following BKV, whereas delayed graft function was associated with a lower risk of dnDSA. In conclusion, despite being considered a result of over-immunosuppression, BKV can still be followed by dnDSA in a substantial proportion of patients. Monitoring for dnDSA in patients being managed for BKV may be warranted. Copyright© 2017 by the Terasaki Research Institute.

  18. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  19. The protection of radioactive nuclide and nursing management in DSA room

    International Nuclear Information System (INIS)

    Zhang Guimin

    2009-01-01

    Objective: To discuss the protection of radioactive nuclide and nursing management in DSA room. Methods: The clinical state of the protection of radioactive 131 I nuclide and nursing management in DSA room was retrospectively summarized. Results: The standard management for the protection of radioactive nuclide in DSA room was established. The main management schemas included the management of personnel, the management of professional skills and, specialty, the management of radioactive drugs and abandoned odds and ends, preoperative health education, etc. Conclusion: The standard management can ensure that the patients get a good radionuclide therapy in DSA room, and, at the same time, the working environment can be effectively protected and the professional nursing staff can be well trained. (authors)

  20. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  1. Indications for intravenous and intraarterial digital subtraction angiography (DSA) in the diagnosis of cerebrovascular insufficiency

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.

    1985-01-01

    For screening of arteriosclerotic lesions of the carotid bifurcation duplex scanning (B-mode imaging plus doppler flow analysis) is the method of first choice, because it is really noninvasive and offers the same results as intravenous DSA (IV DSA). IV DSA should not be performed as a screening procedure unless ultrasound examinations are not available or are inadequate. Except for patients with isolated unilateral stenosis of the internal carotid artery near the bifurcation confirmed with both duplex scanning and IV DSA, arteriography is required for therapy planning. Aortic arch angiogram, selective extra- and intracranial carotid arteriography and - if necessary - vertebral and subclavian arteriography can be performed with intraarterial DSA (IA DSA). The application of DSA to catheter arteriography will help to reduce further the potential risk of adverse reactions related to high intravasal contrast does specially in the cerebral circulation, but will not turn arteriography into a risk-free procedure. Postoperative examinations of the carotid bifurcation can be performed with ultrasound as well as with IV DSA. Extracranial bypasses are best demonstrated with IV DSA. Extraintracranial bypasses can be demonstrated only with IA DSA. (orig.)

  2. Preoperative imaging in 78 living kidney donors using CE-MRA and DSA

    International Nuclear Information System (INIS)

    Lemke, U.; Taupitz, M.; Hamm, B.; Kroencke, T.J.; Kluener, C.; Giessing, M.; Schoenberger, B.

    2008-01-01

    Purpose: to evaluate contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and digital subtraction angiography (DSA) in comparison with the intraoperative findings in living kidney donors. Materials and methods: a total of 156 kidneys in 78 potential kidney donors were prospectively examined using CE-MRA (0.2 mmol Gd/kg, voxel size 1.3 x 0.8 x 2.0) and DSA. Two experienced radiologists assessed the images in consensus regarding the renal vascular anatomy and variants. The results for the 67 candidates accepted for donation were compared to the intraoperative findings. In the other kidneys not accepted for donor nephrectomy, MRA and DSA were compared with each other. Results: nineteen arterial variants were identified intraoperatively, of which 11 (58%) were also detected by preoperative CE-MRA and 10 (53%) by preoperative DSA. Of the 10 venous variants found intraoperatively, CE-MRA detected 8 (80%) and DSA 3 (30%). The agreement (kappa test) between MRI and DSA for all 156 evaluated kidneys was 0.7 for arterial variants (McNemar p = 0.12) and 0.3 for venous variants (McNemar p = 0.01). The preoperative choice of kidney (right or left) made on the basis of the renal vascular anatomy seen on CE-MRA and DSA differed in 22% of the 78 potential donors (McNemar P = 0.3). (orig.)

  3. The availability of DSA used continuous intraarterial infusion tubes founded various malignancy

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Kobayashi, Nobuyuki; Yamada, Tetsuya

    1987-01-01

    DSA was employed using continuous intraarterial infusion tubes for various malignancies (73 cases) which were examined a total of 135 times. In head and neck malignancy (50 cases), the general position of the infusion tube had been determined beforehand by dye infusion, but DSA from the tube showed that the tubes in 24 cases (48 %) were located in the wrong position, especially in tongue cancer (21 cases) where many tubes were discovered to be in an erroreous position (71 %) such as the common carotid artery. We were unable to determine the effect of chemotherapy and radiation using DSA only. In 9 cases of breast cancer for which fixation of the tube was not attempted under X-ray fluoroscopy, 7 (78 %) showed an unusual tube position such as the intraaortic arch. In 5 cases of abdominal malignancy, only the tube position for sigmoid colon cancer was unusual. We were able to observe the effect of chemotherapy by DSA in 2 cases. For DSA in one out of 3 hepatomas using a Port-A-Cath, we observed that infusion of anticancer drug with degradable starch microspheres caused a reduction in tumor size. However, in the two remaining cases, we were unable to observe any effect of infusion of these drugs by DSA for various mechanical reasons. DSA from an infusion tube revealed not only the location of the tube accurately and promptly, but also the effect of chemotherapy. (author)

  4. The clinical application of inferior vena caval CO2-DSA

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Li Guozhao; Fang Wen; He Shicheng; Deng Tang

    2007-01-01

    Objective: To explore the feasibility and safety of inferior vena caval CO 2 -DSA and evaluate the results of inferior vena cavography using CO 2 -DSA or iodinated contrast media. Methods: 25 patients diagnosed as deep venous thrombosis of lower limb were prepared to conceive the implantation of inferior vena caval filter. The inferior vena cava and right renal vein CO 2 -DSA and iodinated contrast media DSA were carried out through jugular or femoral vein approach in all patients. Results: The inferior vena caval angiography with CO 2 -DSA or iodinated contrast media were carried out successfully in all patients. The quality of the inferior vena caval angiogram showed: with CO 2 as contrast media, 14 cases obtained excellent images and 11 cases had good images; with iodinated contrast media the images of 18 cases were excellent and 7 cases were good. No thrombus and variation of inferior vena cava were found by the two kinds of angiography. The diameter of inferior vena cava showed: (20.01 ± 0.83) mm with CO 2 contrast media and (20.15 ± 0.92) mm with iodinated contrast media, (P=0.006); having statistical significance between them. The safety of angiography with CO 2 presented only 1 case with transient slight decrease of O 2 saturation. No abnormal changes were found in blood pressure, heart rate and so on. Conclusions: Inferior vena caval CO 2 -DSA is feasible and safe, with statistical significance in the measurement of inferior vena caval diameter comparing with iodinated contrast material but with no influence on the implantation of filter. (authors)

  5. Correlation between the clinical presentation and DSA of intracranial aneurysms

    International Nuclear Information System (INIS)

    Fang Chun; Hua Jia; Chen Kemin; Yin Yan; Ge Xin; Ying Yiping

    2001-01-01

    Objective: To evaluate the correlation between the clinical presentation and cerebral angiographic features of intracranial aneurysms. Methods: The authors retrospectively analyzed the relationship between the size, location and shape of 48 patient's cerebral aneurysms and their clinical presentations. Results: Clinical symptoms of cerebral aneurysms were related with their size, location and shape. Aneurysms in different location or at same location may cause similar symptoms or different symptoms. Rotation DSA is a useful examination supplemented to conventional DSA. Conclusions: The relationship between the location and the presentation of intracranial aneurysms is not specific. Rotation DSA plays important role in showing the characteristics of the cerebral aneurysms

  6. Dsa examination and diagnosis of arteriovenous shunts in hepatic cavernous hemangiomas of adults

    International Nuclear Information System (INIS)

    Ouyang Yong; Ouyang Xuehui; Gu Subin; Zhou Qunhui

    2000-01-01

    Objective: To correct the misunderstanding that arteriovenous shunts (AVS) are rarely found in adult cavernous hemangiomas of the liver (CHL) and to increase its diagnosis rate by DSA. Methods: DSA examination and DSA images of thirty adults with definitely diagnostic CHL and without evidence of other hepatic diseases and hepatic injury were analyzed retrospectively. X-ray films of 21 cases with AVS taken immediately after transcatheter arterial embolization using lipiodol (L-TAE) were compared with the corresponding DSA images to check up those AVS opacified in DSA by observing sediment and distribution of iodized oil injected. Results: Definite diagnosis of AVS by DSA were obtained in 22 cases of this series (73%). All the AVS were located in the peritumoral parenchyma and appeared as parallel track sign, and early opacification of small draining veins, etc. during arterial phase of DSA. X-ray films taken immediately after L-TAE in 21 of 22 cases with AVS showed that few portal radicles or draining veins were refilled by iodized oil through incompletely occluded shunts in 11 cases, and no any vein was refilled by iodized oil resulted from complete occlusion of the present AVS in 10. No definite AVS was found in the other 8 cases of this series, and in 6 of them improper imaging factors of DSA were used. Conclusion: This study serves to emphasize that AVS is not a diagnosis of hepatic malignancy, but is frequently seen in the commonly benign CHL of adults. Proper imaging factors of DSA and superior images can be helpful to opacify small AVS of CHL. The formation of AVS in CHL may be closely related to the pathological changes of peritumoral parenchyma, however, its mechanism must be further studied

  7. Complications of intravenous DSA: Results in 500 patients

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Neufang, K.F.R.; Beyer, D.; Steinbrich, W.

    1987-01-01

    500 patients were studied respectively for complications of intravenous digital subtraction angiography (IV-DSA) performed with non-ionic contrast media, using a central venous injection technique. In 21 patients (4,2%) during or shortly after the procedure 23 systemic, 1 neurologic, and 7 local complications occurred. In addition, 1 patient developed acute renal failure 26 hours after the IV-DSA, whereas 4 patients later showed on thromboses of the catheterised vein. No permanent neurologic or systemic complications and severe allergic reactions were seen. (orig.) [de

  8. Measurements of image characteristics of DSA installations

    International Nuclear Information System (INIS)

    Busch, H.P.; Strauss, L.G.; Freimarck, R.D.

    1984-01-01

    Measurements for quantifying the image characteristics were carried out on three DSA installations (DVI 1 - Philips, Angiotron - Siemens and DF 3000 - General Eletric). Contrast resolution was measured with a vessel phantom (General Electric) and spatial resolution with a lead grid. A further parameter was the dose entering the image intensifier. The Angiotron was used with an intensifier with 53 cm. diameter and the DF 3000 with temporal subtraction of the video images and the subtraction of dual energy images (hybrid technique). These measurements can be carried out quickly and easily and are a step towards standardisation of measurements of image characteristics of DSA installations. (orig.) [de

  9. Visceral angiography with intra-arterial DSA and a programmed 100 mm technique

    International Nuclear Information System (INIS)

    Triller, J.; Ackermann, B.; Jung, H.

    1988-01-01

    One hundred and seventy specially selected visceral angiograms were carried out of 96 patients using I-A DSA and 100 mm technique. 85.2% of the I-A DSA and 91.7% of the 100 mm images were of good quality. I-A DSA produced comparable or better quality than the 100 mm technique in 66% during the arterial phase, in 79% during the paranchymatous phase and in 70% during the venous phase. The 100 mm technique produced better quality in a third of the cases during the arterial phase and in a quarter of the cases during the parenchymal and venous phases. The indications for the 100 mm technique are failure of I-A DSA or the need for high spatial resolution. (orig.) [de

  10. Prediction of tumor-brain adhesion in intracranial meningiomas by MR imaging and DSA

    International Nuclear Information System (INIS)

    Takeguchi, Takashi; Miki, Hitoshi; Shimizu, Teruhiko; Kikuchi, Keiichi; Mochizuki, Teruhito; Ohue, Shiro; Ohnishi, Takanori

    2003-01-01

    The purpose of this study was to evaluate the usefulness of MRI (magnetic resonance imaging) and DSA (digital subtraction angiography) by using preoperative MRI and DSA findings in the examination of meningiomas before excision. In particular, we focused on their usefulness in predicting tumor-brain adhesion during surgery. The subjects were 36 patients with intracranial meningioma who underwent tumor excision at which time neurosurgeons examined the tumor-brain adhesion. Two neurosurgeons evaluated the degree of tumor-brain adhesion from operation records and videotapes recorded during surgery. Two neuroradiologists retrospectively evaluated the preoperative MRI findings including tumor diameter, signal intensity of the tumor parenchyma obtained with T 2 -weighted imaging (T 2 WI), characteristics of the tumor-brain interface, and degree of peritumoral brain edema. The vascular supply was also evaluated from the preoperative DSA findings. The relationship between these MRI and DSA findings and the degree of tumor-brain adhesion during surgery as classified by the neurosurgeons was statistically analyzed. The degree of peritumoral brain edema and the shapes and characteristics of the tumor-brain interface, including the findings of FLAIR (fluid-attenuated inversion recovery) imaging and vascular supply observed by DSA, were significantly correlated with tumor-brain adhesion. In particular, the shapes and characteristics of the tumor-brain interface as observed by T 1 -weighted imaging (T 1 WI), T2WI, and FLAIR, respectively, as well as the vascular supply observed by DSA, were closely correlated with the degree of tumor-brain adhesion encountered during surgery. According to these results, we developed a method of predicting tumor-brain adhesion that considers the shape of the tumor-brain interface revealed by MRI and the vascular supply revealed by DSA. We retrospectively examined the findings of MRI and DSA performed before excision of meningioma and clarified

  11. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  12. Internal carotid artery stenosis or occlusion: study of collateral circulation pathways on DSA and MRA

    International Nuclear Information System (INIS)

    Zhao Yunhui; Ma Zhubin; Xu Yikai

    2004-01-01

    Objectives: To evaluate the collateral pathways of internal carotid artery (ICA) stenosis or occlusion on digital subtraction angiography (DSA) and magnetic resonance angiography (MRA), and to compare these two methods in the study for collateral pathways. Methods: Seventy-four patients with ICA stenosis or occlusion were included as the study group. Sixty persons with normal findings on DSA or MRA each served as the control group. DSA, MRA, MRI, CT findings, and clinicall materials were analyzed in the two groups. Results: Stenosis or occlusion over ICA bifurcation was showed clearly in all patients on DSA or MRA. On DSA, the presence rate of ipsilateral posterior communicating artery (PCoA) in the study group (82.5%) was lower significantly than that of the control group (94.2%) (P=0.025). On MRA (3D-TOF), the rate in the study group (59.3%) was higher significantly than that of the controls (30.0%) (P=0.000). On DSA and MRA, the diameter of ipsilateral PCoA in the study group was larger than that of the control group (P=0.000). On DSA, the presence rate of OPhA in the study group was significantly different from that of the control group, and its diameter was larger than that of the control group (P=0.003). On MRA, its presence rate was lower than that of the control group. The presence rate of anterior communicating artery (ACoA) in the study group showed no statistical difference between DSA and MRA. In the study group, the presence rate of PCoA on DSA was significantly higher than that on MRA (P 0.05). The diameters of the three arteries showed no significant differences between DSA and MRA (P>0.05). Conclusion: DSA is highly valuable for the evaluation of collateral pathways of ICA stenosis or occlusion, and it is necessary for preoperative examination. MRA is a non-invasive angiographic method and can evaluate collateral circulation in both morphology and function, and can be the preferred method for the disease. (authors)

  13. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  14. Evaluation of DSA test phantoms commercially available in the UK

    International Nuclear Information System (INIS)

    Cowen, A.R.; Coleman, N.J.; HArtley, P.J.

    1985-01-01

    Several digital subtraction angiography systems have been installed in the United Kingdom. Many others will no doubt be installed over the next few years. Given the high cost and technical complexity of DSA systems it is natural that the purchasers of such equipment should be concerned that their machine has been adjusted correctly prior to clinical acceptance and continues to operate satisfactorily thereafter. In response to these concerns several companies in the U.K. are now selling DSA test phantoms. All DSA phantoms which are currently commercially available are manufactured in the U.S.A. Im order to assess the effectiveness of these phantoms the DHSS has initiated the assessment project described here. The findings are tabulated . Performance is indicated by a star rating system, based on the opinions of two X-ray engineers and one medical physicist. (author)

  15. IV-DSA of vertigo patients

    International Nuclear Information System (INIS)

    Watanabe, Hiromi; Ito, Masatoshi; Takita, Kimio; Matsuzawa, Taiju.

    1988-01-01

    With IV-DSA(Intra-Venous Digital Subtraction Angiography), we examined the relations between vertigo or dizziness and asymmetries of cervical vertebral arteries. In this time, as the asymmetries we chose next three; hemi-stenosis, hemi-occulusion and hemi-strong tortuosity. In the appearance of the asymmetries, there was no differance between those who complain vertigo or dizziness and others. (author)

  16. Software-assisted CT-postprocessing of the carotid arteries

    International Nuclear Information System (INIS)

    Gerhards, A.; Raab, P.; Herber, S.; Kreitner, K.F.; Mildenberger, P.

    2004-01-01

    Purpose: A software assistant for automatic evaluation of CT-angiograms (CTA) was developed. It should enable the visualization of the vessel lumen and the quantitative evaluation of a stenosis. CTA examinations of patients with suspected carotid artery stenoses were used for the evaluation of the software assistant. Materials and Methods: Twelve Patients with suspected highgrade stenosis of the carotid arteries underwent a CTA examination using a multislice CT scanner. The data were analyzed and evaluated using the new software assistant. The results were compared with the data of digital subtraction angiography (DSA) of these patients. Results: The time of digital postprocessing with the new software-assistant took about six minutes on average. Contour extraction of the vessel, MIP and curved MPR (c-MPR) and orthogonal cross-sectional images of the vessels were calculated, followed by an automatic quantification of stenosis by the use of the C-MPR. A good correlation was found between CTA and DSA data regarding the stenosis grade (r=0.82). Furthermore, some information could be provided about the plaque morphology. Conclusion: The software-assisted detection and analysis of carotid artery stenosis with the new developed program is possible within a justifiable time. DSA- and CTA-data did not show a significant difference in stenosis grading. Further development of software tools could lead to a better characterization of plaque morphology. (orig.) [de

  17. DSA volumetric 3D reconstructions of intracranial aneurysms: A pictorial essay

    Science.gov (United States)

    Cieściński, Jakub; Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-01-01

    Summary A gold standard of cerebral vessel imaging remains the digital subtraction angiography (DSA) performed in three projections. However, in specific clinical cases, many additional projections are required, or a complete visualization of a lesion may even be impossible with 2D angiography. Three-dimensional (3D) reconstructions of rotational angiography were reported to improve the performance of DSA significantly. In this pictorial essay, specific applications of this technique are presented in the management of intracranial aneurysms, including: preoperative aneurysm evaluation, intraoperative imaging, and follow-up. Volumetric reconstructions of 3D DSA are a valuable tool for cerebral vessels imaging. They play a vital role in the assessment of intracranial aneurysms, especially in evaluation of the aneurysm neck and the aneurysm recanalization. PMID:22844309

  18. IV DSA in the diagnosis and follow-up of dissection of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickx, P.; Luska, G.; Laas, J.; Haverich, A.

    1986-05-01

    Intravenous DSA was performed in 53 patients with suspected dissection of the thoracic aorta and in 13 patients following surgery for aortic dissection. In 36 patients, the suspected diagnosis could be excluded definitely and, in 14 cases out of 17, a dissection was correctly diagnosed. All 11 type B dissections were correctly diagnosed. Of six type A dissections, only three were adequately demonstrated by IV DSA. In type B dissections, IV DSA is reliable, but in type A dissection with massive aortic insufficiency or pericardial tamponade the findings are not reliable. In all 13 patients who had surgery for dissection, IV DSA proved suitable for showing the anastomosis and progress of the disease.

  19. Study of DSA-guided percutaneous puncture location of foramen oval

    International Nuclear Information System (INIS)

    Zhao Xiaojun; He Jiawei; Bai Guanghui; Shi Jianjing; Xu Chongyong; Zhan Gonghao

    2008-01-01

    Objective: To study the technique of digital substraction angiography (DSA)-guided percutaneous puncture location of foramen oval. Methods: 39 cases of trigeminal neuralgia were included in the study from Feb. 2004 to Oct. 2006. The patients were punctured by the amending anterior position. The f0ramen oval was displayed by moving the tube tilted 20-28 degree to the caudal and 16-23 degree to the healthy side. The direction and depth of the needles was determined on the lateral view. Then, radio-frequency thermocoagulation therapy was performed. Results: The needles were located in oval foramen in all the patients. Pain disappeared in 36 cases, alleviated in other cases, and no serious complication occurred during therapy. Conclusions: Oval foramen locations by DSA can improve the successful rate of operation. The foramen oval can be clearly displayed by DSA-guided in amending position, with comfortable position for patients. (authors)

  20. Advantages and limitation of intra-arterial digital subtraction angiography (i.a. DSA)

    International Nuclear Information System (INIS)

    Beduhn, D.

    1986-01-01

    Among 3000 digital subtraction angiographies which have been performed in our institute, 850 patients have been examined intraarterially. The advantage of i.a. DSA is due to the excellent demonstration of vessels in survey angiograms by small amounts of contrast medium (10-20 ml in the aorta), without risk of selective catheterisation into the neck vessels, the saving of expensive film series, the short duration of vessel examinations and the small complication rate. i.a. DSA can be carried out on outpatients also, using the 4/5 F-catheter, which saves hospital charges. Impressive examples show the advantages of i.a. DSA. (orig.) [de

  1. The study of the value of applying the special functions of DSA during uterine artery embolization

    International Nuclear Information System (INIS)

    Wang Ting; Zhao Zhenhua; Lv Weigong

    2007-01-01

    Objective: To study the value of applying the special functions of DSA during uterine artery embolization. Methods: 122 cases were performed uterine artery embolization, including 67 cases with traditional operation and 55 cases with applying the special functions of DSA: rotary DSA angiography, the best work position and road map technology. We recorded the correlative operative indices to compare and analyse the mean exposure time, the mean operative time, the mean dosage of contrast medium, the probability of vasospasm and injury of blood vessel during operation. Results: The mean exposure time, mean operative time and the mean dosage of contrast medium were reduced with the special functions of DSA during uterine artery embolization. There is significant difference between traditional operation and the operation applying the special functions of DSA (P<0.01). Conclusion: Applying the special functions of DSA during uterine artery embolization can reduce the operative time, operative risk and economic burden. (authors)

  2. Diagnostic value of digital subtraction angiography (DSA) using TOSHIBA DIGIFORMER X in the cerebrospinal vascular diseases

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Nakagawa, Yoku; Sawamura, Yutaka; Kobayashi, Nobuaki; Nagashima, Masafumi; Kitaoka, Ken-ichi; Kitagawa, Michio; Itoh, Terufumi; Ohsato, Takao.

    1987-01-01

    Using TOSHIBA Digiformer X, digital subtraction angiography (DSA) was performed in 286 patients, in whom 229 patients of cerebro-spinal vascular disease was included. The authors emphasize the usefulness of DSA in cerebro-spinal vascular disease in relation to conventional angiography. DSA taken by single small dose injection of contrast medium into the ascending aorta clearly demonstrates not only aortic arch and thoracic major vessels, but also cervical vessels and all intracranial vessels. Therefore, we could rapidly understand gross dynamics of the circulation and obtain useful informations prior to catheterization to the selective artery. This advantage of DSA was particularly useful for occlusive vascular diseases. Gradual injection of small dose of contrast medium obviously reduced recoiling of the catheter tip, which enabled the selective angiography with setting of the tip of the catheter at the entrance of cervical major vessels without its sufficient inserion into the selective vessels. This advantage is particularly beneficial for the patients with severe arteriosclerosis who was found to be difficult for selective catheterization. In our experience, demonstration of a presence of aneurysm by DSA was possible in almost all cases of subarachnoid hemorrhage, although spatial resolution of DSA is said to be inferior to the conventional angiography. Real time display of DSA decreased the time required for examination and enabled repeated angiography. This advantage of DSA is especially useful for the patients with spinal arterio-venous malformation and thoracic outlet syndrome. (author)

  3. The clinical value of the special functions of DSA in interventional embolization for uterine fibroids

    International Nuclear Information System (INIS)

    He Yushen; Lu Dong; Lv Weifu; Zhang Jingsong

    2009-01-01

    Objective: To evaluate the special functions of DSA in interventional embolization therapy for uterine fibroids. Methods: The special functions of DSA, including 3D-DSA, the optimal working position and road-mapping technique, were utilized in performing interventional embolization therapy for uterine fibroids in twenty-six cases (experimental group). Routine DSA angiography was employed in twenty cases(control group). The volume of contrast media used, the time of completing the interventional procedure and the total fluoroscopic time in two groups were compared and the results were analyzed. Results: The difference in the volume of contrast agent used and in the total fluoroscopic time between two groups was statistically significant (P 0.05). Conclusion: In treating uterine fibroids with interventional embolization, the use of the special functions of DSA can reduce the manipulation time and lower the operation risk. Moreover, the technique of visible 3D reconstruction image is of great significance in guiding the procedure. (authors)

  4. Clinical application of DSA and evaluation of its methods

    International Nuclear Information System (INIS)

    Ouyang, Yong; Ma, Heping; Gu, Shubing; Zhou, Qunhui; Zhang, Shulan; Liu, Pengzni; Zhang, Junyi.

    1990-01-01

    A total of 160 patients of two hospitals received 192 DSA examinations with different contrast administrations, and techniques of performing DSA were analyzed, compared, and evaluated with reference to the literature. It was concluded that (1) the peripheral injection of contrast material for IVDSA via cannula is simpler than that via a short catheter, but the incidences of contrast extravasation in both cases are higher than with central injection. (2) Both the lower part of the superior vena cava and the right atrial cavity are safe sites for central injection. With central injection for IVDSA, the arterial iodine concentration is approximately double that of peripheral injection, and consistent high quality examinations of the intracranial vessels may be obtained. However, neither peripheral nor central injections can visualize the small vessels clearly. (3) IVDSA may be substituted for conventional angiography only in examinations of the aorta and its main branches. (4) IADSA is becoming a superior angiographic technique and its clinical application is increasing. In addition, means of avoiding contrast extravasation during IVDSA and the main points of selecting the optimal technique for DSA are described in this paper. (author)

  5. CO2-DSA in lower extremity veins: a clinical application

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Liu Zhensheng; Li Guozhao; Ding Huijuan; Shen Zhiping; He Shicheng; Deng Gang; Fang Wen

    2005-01-01

    Objective: To explore the feasibility and usefulness of carbon dioxide digital subtraction angiography (CO 2 -DSA) in deep veins of lower extremity via the dorsal is pedis vein. Methods: CO 2 -DSA in lower extremity veins was performed in 15 patients (15 limbs affected, male 9, female 6) by injection of CO 2 via the dorsal is pedis vein. Among them, 8 patients were suspected with deep venous thrombosis (DVT), 6 patients with saphena magna dilation, and 1 patient with a follow-up after thrombolysis due to DVT. Results: Excellent image was obtained in 12 cases, which showed branches of the venous system clearly, as well as the details of DVT. Good image was obtained in 2 cases. Technical failure was encountered in one patient due to inaccessible puncture veins. Mild discomfort (transient pain at the percutaneous site) during the procedure was demonstrated in 11 patients. There was no severe side effects or complications in this series. Conclusion: CO 2 -DSA in lower extremity veins is feasible and safe, the preliminary result is satisfactory. (authors)

  6. DSA findings and bronchial arterial embolization of bronchiectasis with massive hemoptysis

    International Nuclear Information System (INIS)

    Xu Guobin; Liu Junfang; Hu Jinxiang; Long Qingyun

    2008-01-01

    Objective: To explore DSA findings curative measures and effects of bronchial arterial embolization (BAE)of bronchiectasis with massive hemoptysis. Methods: 35 patients with massive hemoptysis due to bronchiectasis were performed selective bronchial arterial DSA and BAE referring to image data of chest plain film and CT. Embolic materials were polyvinyl alcohol (PVA)and/or gelatinum sponge particles. Curative effects were followed-up for 3 months to 3 years. Results: (1)DSA revealed bronchial artery as being the only abnormal vessel accounted for 74.3%, bronchial artry combined with nonbronchial systemic artery as 22.9% and only non-bronchial artery involved 2.9%. Abnormal vessel number was 1-5 (mean 1.8) per case; Direct and indirect bleeding sign was displayed as 25.7% and 100% respectively. (2)Curative and embolization effects were shown as 61 target vessels of 34 patients being embolized and total effective rate reaching 85.3%; of which 16 cases were adopted super-selective technique, 1 case was failure of stopping bleeding for two times within 3 days, 4 cases recurred within 3 months and 2 cases recurred over 3 months; with recurrent rate of 20.6%, but no serious complications such as spinal cord injury. Conclusions: DSA examination and selective BAE of bronchiectasis with massive hemoptysis could provide high positive angiographic features and reliable curative effect. (authors)

  7. Hepatic VX2 tumor after portal vein occlusion in rabbits: evaluation with DSA

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Zhang Qichuan; Chen Lin; Huang Xiaobing; Huan Guangqiang

    2006-01-01

    Objective: To study the value of DSA for hepatic vascular anatomy, and to evaluate the efficacy of portal vein occlusion in rabbits with hepatic VX2 tumor. Methods: Twenty New Zealand white rabbits were randomly divided into two groups with 10 in each group, including test group A and positive control group B of ham operation. For the test group A, portal branch ligation (PBL) was performed for the left external branch after 3 weeks of the tumor implantation to the left external lobe. Two weeks later, the DSA of hepatic artery and portal vein were performed in all of the rabbits. Results: The total displaying effectiveness of the branches of hepatic artery by DSA was better than that by vascular perfusion. There was hypovascular blood supply to hepatic artery implantation of the tumor in the test group A, comparing with that of the group B. Conclusion: DSA can clearly display special details of the hepatic vascular anatomy in rabbits, and play an important role in post-procedural evaluation of the portal vein occlusion in rabbits. (authors)

  8. Benign Prostatic Hyperplasia: Cone-Beam CT in Conjunction with DSA for Identifying Prostatic Arterial Anatomy.

    Science.gov (United States)

    Wang, Mao Qiang; Duan, Feng; Yuan, Kai; Zhang, Guo Dong; Yan, Jieyu; Wang, Yan

    2017-01-01

    Purpose To describe findings in prostatic arteries (PAs) at digital subtraction angiography (DSA) and cone-beam computed tomography (CT) that allow identification of benign prostatic hyperplasia and to determine the value added with the use of cone-beam CT. Materials and Methods This retrospective single-institution study was approved by the institutional review board, and the requirement for written informed consent was waived. From February 2009 to December 2014, a total of 148 patients (mean age ± standard deviation, 70.5 years ± 14.5) underwent DSA of the internal iliac arteries and cone-beam CT with a flat-detector angiographic system before they underwent prostate artery embolization. Both the DSA and cone-beam CT images were evaluated by two interventional radiologists to determine the number of independent PAs and their origins and anastomoses with adjacent arteries. The exact McNemar test was used to compare the detection rate of the PAs and the anastomoses with DSA and with cone-beam CT. Results The PA anatomy was evaluated successfully by means of cone-beam CT in conjunction with DSA in all patients. Of the 296 pelvic sides, 274 (92.6%) had only one PA. The most frequent PA origin was the common gluteal-pudendal trunk with the superior vesicular artery in 118 (37.1%), followed by the anterior division of the internal iliac artery in 99 (31.1%), and the internal pudendal artery in 77 (24.2%) pelvic sides. In 67 (22.6%) pelvic sides, anastomoses to adjacent arteries were documented. The numbers of PA origins and anastomoses, respectively, that could be identified were significantly higher with cone-beam CT (301 of 318 [94.7%] and 65 of 67 [97.0%]) than with DSA (237 [74.5%] and 39 [58.2%], P < .05). Cone-beam CT provided essential information that was not available with DSA in 90 of 148 (60.8%) patients. Conclusion Cone-beam CT is a useful adjunctive technique to DSA for identification of the PA anatomy and provides information to help treatment planning

  9. Survey of DSA-certified digital repositories : Report on the findings in a survey of all DSA-certified digital repositories on investments in and benefits of acquiring the Data Seal of Approval (DSA)

    NARCIS (Netherlands)

    Waterman, Kees-Jan; Sierman, Barbara

    2016-01-01

    The Data Seal of Approval (DSA) has been in use as a certification instrument for trustworthy digital repositories (TDRs) since 2010. By March 2016 some 50 repositories had applied successfully for the seal. Whereas some organizations and repositories have published about their own experiences in

  10. Value of digital angiography as a substitute for film angiography in comparison with DSA

    International Nuclear Information System (INIS)

    Langer, M.; Mitsch, E.; Zwicker, C.; Scholz, A.; Felix, R.; Langer, R.

    1988-01-01

    The authors performed a prospective study to evaluate whether digital angiography (DA) can provide diagnostic image quality to reduce the need for film studies. The study is based on more than 100 arterial DSA examinations that were intra- and interindividually compared with the DA studies of the same arteries. It was demonstrated that DA with the same quantity of contrast medium as DSA is diagnostic in 80% of cases for abdominal, pelvic, and femoral arteries and in 85% for brachial arteries but in only 56% for carotid arteries if an aortic arch injection is performed. For all examinations, image quality with DSA was excellent in 86%, good in 9%, and diagnostic in 5%, with DA, it was excellent in 5%, good in 49%, diagnostic in 22%, and bad in 24% (90% of these were supraaortic studies). The results of this study indicate that it is worth trying a DA study when DSA is nondiagnostic because of artifacts, if a selective intraarterial contrast medium injection can be performed

  11. The internal carotid artery stenosis or occlusion. The evaluation for the posterior communicating artery on DSA and MRA

    International Nuclear Information System (INIS)

    Zhao Yunhui; Gao Xinjiang; Ma Zhubin; Xu Yikai

    2003-01-01

    Objective: To study the changes of the posterior communicating artery in patients with internal carotid artery (ICA) severe stenosis or occlusion on digital subtract angiography (DSA) and magnetic resonance angiography (MRA). Methods: DSA or MRA findings were analyzed in 74 patients with ICA stenosis or occlusion and in 120 persons selected in the control group, who were unremarkable on cerebral DSA or MRA. Results: On DSA, the presence rate of ipsilateral posterior communicating artery (PCoA) between the study group and the control group had no significant difference; on MRA the rate in the study group was significantly higher than the control group (P 0.05). In the study group, the presence rate of PCoA on DSA was significantly higher than that on MRA (P 0.05). The presence rate of PCoA shown no significant difference between the cases with unilateral ICA involved and cases with bilateral ICA involved. Conclusion: The posterior communicating artery is very important to the patients with the internal carotid artery stenosis or occlusion. Its dilatation on DSA and MRA or appearance on MRA shows its compensation. DSA is valuable in the evaluation of the posterior communicating artery. MRA is a noninvasive and functional imaging method for evaluation the posterior communicating artery

  12. Electrochemical treatment of tannery wastewater using DSA electrodes

    International Nuclear Information System (INIS)

    Costa, Carla Regina; Botta, Clarice M.R.; Espindola, Evaldo L.G.; Olivi, Paulo

    2008-01-01

    In this work we studied the electrochemical treatment of a tannery wastewater using dimensionally stable anodes (DSA) containing tin, iridium, ruthenium, and titanium. The electrodes were prepared by thermal decomposition of the polymeric precursors. The electrolyses were performed under galvanostatic conditions, at room temperature. Effects of the oxide composition, current density, and effluent conductivity were investigated, and the current efficiency was calculated as a function of the time for the performed electrolyses. Results showed that all the studied electrodes led to a decrease in the content of both total phenolic compounds and total organic carbon (TOC), as well as lower absorbance in the UV-vis region. Toxicity tests using Daphnia similis demonstrated that the electrochemical treatment reduced the wastewater toxicity. The use of DSA type electrodes in the electrochemical treatment of tannery wastewater proved to be useful since it can promote a decrease in total phenolic compounds, TOC, absorbance, and toxicity

  13. Electrochemical treatment of tannery wastewater using DSA electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Carla Regina [Departamento de Quimica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, CEP 14049-901 Ribeirao Preto, SP (Brazil); Botta, Clarice M.R.; Espindola, Evaldo L.G. [Nucleo de Estudos em Ecossistemas Aquaticos, Centro de Recursos Hidricos e Ecologia Aplicada, Escola de Engenharia de Sao Carlos, Universidade de Sao Paulo, CP 292, CEP 13560-970 Sao Carlos, SP (Brazil); Olivi, Paulo [Departamento de Quimica, Faculdade de Filosofia, Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, CEP 14049-901 Ribeirao Preto, SP (Brazil)], E-mail: olivip@ffclrp.usp.br

    2008-05-01

    In this work we studied the electrochemical treatment of a tannery wastewater using dimensionally stable anodes (DSA) containing tin, iridium, ruthenium, and titanium. The electrodes were prepared by thermal decomposition of the polymeric precursors. The electrolyses were performed under galvanostatic conditions, at room temperature. Effects of the oxide composition, current density, and effluent conductivity were investigated, and the current efficiency was calculated as a function of the time for the performed electrolyses. Results showed that all the studied electrodes led to a decrease in the content of both total phenolic compounds and total organic carbon (TOC), as well as lower absorbance in the UV-vis region. Toxicity tests using Daphnia similis demonstrated that the electrochemical treatment reduced the wastewater toxicity. The use of DSA type electrodes in the electrochemical treatment of tannery wastewater proved to be useful since it can promote a decrease in total phenolic compounds, TOC, absorbance, and toxicity.

  14. Efficacy of balloon temporary occlusion and intraoperative DSA in surgically difficult aneurysm

    International Nuclear Information System (INIS)

    Ezura, Masayuki; Mizoi, Kazuo; Yoshimoto, Takashi; Takahashi, Akira.

    1993-01-01

    A digital subtraction angiographic (DSA) apparatus has been installed in one of our operating rooms since April 1987. We performed intraoperative DSA in 42 aneurysmal surgeries in 38 patients and balloon temporary occlusion in 33 surgeries. The aneurysm was on an internal carotid artery in 26 cases and on the vertebro-basilar system in 16. A heparin-coated catheter (Anthron, Toray, Tokyo), 6 french in diameter, was inserted transfemorally and was put in a parent artery under general anesthesia. A balloon was temporarily inflated to determine inflation volume. The balloon catheter was soon deflated and was drawn back into the introducing catheter to avoid developing microembolus. The patients were not systemically heparinized but the introducing catheters were slowly flushed with heparinized saline during operation. Then a craniotomy was carried out. Next DSA was performed when temporary occlusion or confirmation of clipping was necessary. In cases of balloon temporary occlusion, the operating field was not obstructed as it is when a temporary clip is used, despite adequate flow reduction of the parent artery. After DSA for confirmation of clipping adjustment of it was performed in 12 cases out of 42. No complications occurred due to use of an introducing or a balloon catheter. We conclude that combined intravascular and neurosurgical approach, particularly for the large aneurysms with the difficulty of proximal control, can be a useful method of treatment. (author)

  15. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  16. [2011 Shanghai customer satisfaction report of DSA/X-ray equipment's after-service].

    Science.gov (United States)

    Li, Bin; Qian, Jianguo; Cao, Shaoping; Zheng, Yunxin; Xu, Zitian; Wang, Lijun

    2012-11-01

    To improve the manufacturer's medical equipment after-sale service, the fifth Shanghai zone customer satisfaction survey was launched by the end of 2011. The DSA/X-ray equipment was setup as an independent category for the first time. From the survey we can show that the DSA/X-ray equipment's CSI is higher than last year, the customer satisfaction scores of preventive maintenance and service contract are lower than others, and CSI of local brand is lower than imported brand.

  17. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    Science.gov (United States)

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample

  18. Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Ewen, K.

    1986-01-01

    The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.)

  19. DSA diagnosis and embolization therapy of gastrointestinal hemorrhage

    International Nuclear Information System (INIS)

    Zhou Ruming; Qiu Shuibo; Liu Minhua; Yang Huijun; Zhuang Shaoyu

    2006-01-01

    Objective: To evaluate the effect of digital subtraction angiography and transcatheter embolization for gastrointestinal hemorrhage. Methods: Twenty patients with gastrointestinal hemorrhage received celiac arteries, superior mesenteric arteries and inferior mesenteric arteries angiography. Superselective angiography were performed when the arteries were suspicious by clinic or angiogrraphy. Ten patients with definite diagnosis and manifestation of hemorrhagic arteries by angiography were embolized after superselective catheterization with gelfoam particles, gelfoam particles and coils, polyvinyl alcohol particles. Results: The positive signs were observed in 13 cases. The DSA features including contrast medium accumulation in the gastrointestinal tract outside vascular, aneurysm, tumorous vascularization and staining, artery affect and local vasospasm. The bleedings were stopped immediately in 8 patients. No rebleeding and intestinal ischaemia or necrosis were observed in 30 days. One patient died in the second day after embolization from multiple organ failure. Rebleeding occurred 3 days after embolization in another patient, and was recovered after surgical operation. Conclusion: DSA is more effective for the diagnosis of gastrointestinal vascular malformation and tumors complicating acute bleeding. Transcatheter embolization is effective and safe to control the hemorrhage. (authors)

  20. 3D DSA findings of uterine artery and its optimal projection position

    International Nuclear Information System (INIS)

    Lu Weifu; Zhang Aiwu; Zhou Chunze; Lu Dong; Xiao Jingkun; Wang Weiyu; Zhang Xingming; Zhang Zhengfeng; Hou Changlong

    2011-01-01

    Objective: to observe the origin site, anatomic features of uterine artery with 3D DSA and to discuss the optimal projection position in order to improve the success rate of super-selective catheterization of uterine artery. Methods: Prospective pelvic angiography was performed in 42 adult females (a total of 84 uterine arteries). 3D DSA was carried out with 206 ° rotation. 3D reconstruction of the obtained images was performed and the angiographic manifestations of the uterine artery were analyzed. The optimal projection position for the displaying of uterine artery was discussed. The quality of images obtained with the projection angle of 15 °-25 °, 25 °-35 ° and 35 °-45 ° was determined and the results were compared with each other. Results: The orifices of all 84 uterine arteries could be well demonstrated on 3D DSA images. The uterine artery was originated from the anterior trunk of internal iliac artery (n=58, 69%), from main stem of internal iliac artery (n=16, 19.1%), from internal pudenda artery (n=8, 9.5%) and from inferior gluteal artery (n=2, 2.4%). The best projection position to show the opening and route of the uterine artery was contralateral oblique view of 25-35 degrees (P<0.05). Conclusion: 3D DSA can clearly display the anatomy of the uterine artery, which is very helpful for the management of super-selective catheterization of uterine artery. The optimal projection position for uterine artery is contralateral oblique view of 25-35 degrees. (authors)

  1. Electrochemical oxidation of bio-refractory dye in a simulated textile industry effluent using DSA electrodes in a filter-press type FM01-LC reactor.

    Science.gov (United States)

    Rodríguez, Francisca A; Mateo, María N; Aceves, Juan M; Rivero, Eligio P; González, Ignacio

    2013-01-01

    This work presents a study on degradation of indigo carmine dye in a filter-press type FM01-LC reactor using Sb2O5-doped Ti/IrO2-SnO2 dimensionally stable anode (DSA) electrodes. Micro- and macroelectrolysis studies were carried out using solutions of 0.8 mM indigo carmine in 0.05 M NaCl, which resemble blue denim laundry industrial wastewater. Microelectrolysis results show the behaviour of DSA electrodes in comparison with the behaviour of boron-doped diamond (BDD) electrodes. In general, dye degradation reactions are carried out indirectly through active chlorine generated on DSA, whereas in the case of BDD electrodes more oxidizing species are formed, mainly OH radicals, on the electrode surface. The well-characterized geometry, flow pattern and mass transport of the FM01-LC reactor used in macroelectrolysis experiments allowed the evaluation of the effect of hydrodynamic conditions on the chlorine-mediated degradation rate. Four values of Reynolds number (Re) (93, 371, 464 and 557) at four current densities (50, 100, 150 and 200 A/m2) were tested. The results show that the degradation rate is independent of Re at low current density (50 A/m2) but becomes dependent on the Re at high current density (200 A/m2). This behaviour shows the central role of mass transport and the reactor parameters and design. The low energy consumption (2.02 and 9.04 kWh/m3 for complete discolouration and chemical oxygen demand elimination at 50 A/m2, respectively) and the low cost of DSA electrodes compared to BDD make DSA electrodes promising for practical application in treating industrial textile effluents. In the present study, chlorinated organic compounds were not detected.

  2. The placement of naso-jejunal feeding tube under DSA guidance: its technology and skills

    International Nuclear Information System (INIS)

    Song Laichang; Wang Wenhui; Li Fenqiang; Su Dongjun; Li Bo

    2009-01-01

    Objective: To retrospectively analyze and summarize the manipulation and skills of the placement of naso-jejunal feeding tube under DSA guidance. Methods: After performing the spraying anesthesia of nasopharynx, the naso-jejunal feeding tube, with the help of guide wire and under DSA guidance, was placed into the proximal jejunum by passing it through the nose, pharynx, esophagus, stomach, pylorus and duodenum in order. The procedure was employed in 441 cases. Results: The mean time for performing the procedure was within five minutes. The procedure was successfully accomplished in all 441 cases and no complications occurred in this series. Conclusion: Under DSA guidance the placement of naso- jejunal feeding tube can be safely and quickly carried out with high successful rate and less sufferings to patient. It is worth popularizing this technique in clinical practice. (authors)

  3. Application of DSA and ultrasonic blood rheography (Doppler) to benign paroxysmal positional vertigo

    International Nuclear Information System (INIS)

    Fujita, Nobuya; Wada, Yoshiro; Suzumura, Shigeo; Matsunaga, Takashi

    1990-01-01

    Fourteen cases of benign paroxysmal positional vertigo (BPPV) were studied with cervical circulation using DSA and Doppler. DSA study showed 7 abnormal cases out of 10 cases of BPPV. The abnormal findings included 5 cases of stenosis and 5 cases of coiling and kinking in cervical vertebral arteries. Doppler study showed that vertebral a. and also carotid a. had low volume and high laterality of cervical blood circulation in parameter of flow and velocity. These findings suggest the cervical circulation disorder was one of background factors in pathogenesis of BPPV. (author)

  4. Application of DSA and ultrasonic blood rheography (Doppler) to benign paroxysmal positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuya; Wada, Yoshiro; Suzumura, Shigeo; Matsunaga, Takashi (Nara Medical Univ., Kashihara (Japan))

    1990-03-01

    Fourteen cases of benign paroxysmal positional vertigo (BPPV) were studied with cervical circulation using DSA and Doppler. DSA study showed 7 abnormal cases out of 10 cases of BPPV. The abnormal findings included 5 cases of stenosis and 5 cases of coiling and kinking in cervical vertebral arteries. Doppler study showed that vertebral a. and also carotid a. had low volume and high laterality of cervical blood circulation in parameter of flow and velocity. These findings suggest the cervical circulation disorder was one of background factors in pathogenesis of BPPV. (author).

  5. Selective transcervical tubal recanalisation using DSA

    International Nuclear Information System (INIS)

    Kelekis, D.; Fezoulidis, I.; Petsas, T.; Tsapalira, A.; Kelekis, N.

    1991-01-01

    The results of selective transcervical tubal recanalisation by means of a catheter in 20 patients with tubal occlusions are reported and discussed. The advantages of tubal recanalisation under DSA are stressed. In 18 (90%) of the 20 patients treated, it was possible to recanalise at least one tube. Nine of these 18 women (50%) became pregnant during the period of observation, averaging 12 months. Selective transcervical recanalisation of obstructive tubes is a rapid, reliable, cheap and hardly invasive treatment of sterility, when compared with laparoscopy or laparotomy. In the majority of patients it makes surgery unnecessary. (orig.) [de

  6. Indications for intra-arterial digital subtraction angiography (DSA) in vascular disease

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.; Peters, P.E.; Moedder, U.

    1983-01-01

    Digital subtraction angiography (DSA), using a direct arterial route, diminishes the risk of the examination by reducing the contrast dose by about 75%, making the examination more rapid and making it less likely that catheters will have to be changed. At the same time superimposition is avoided, one of the advantages of selective catheterisation. In view of the low contrast dose, it is possible to carry out several examinations at one time and to use additional projections for intracranial and peripheral disease, thereby improving the diagnostic value of the examination. For certain problems, intra-arterial DSA is already able to replace conventional angiography. The small field size and poor spatial resolution still make conventional angiography necessary as the basic form of investigation in most other circumstances. (orig.) [de

  7. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  8. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  9. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Department of Radiology and Diagnostic Imaging, Collegium Medicum, Bydgoszcz (Poland); Beuth, Wojciech [University of Humanities and Economics in Wloclawek, Faculty of Health Sciences, Wloclawek (Poland)

    2012-12-15

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 {+-} 19.0 mm{sup 3} in TOF-MRA to 30.5 {+-} 44.6 mm{sup 3} in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  10. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm 3 in TOF-MRA to 30.5 ± 44.6 mm 3 in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization. (orig.)

  11. Experimental research on local renal injury of dog with microwave ablation guided by DSA

    International Nuclear Information System (INIS)

    Lin Jianping; Xian Zhengyuan; Shi Rongshu; Zhang Gaofeng; Li Xianlang

    2008-01-01

    Objective: To explore the efficiency, complications and probability of preserving part renal function by local renal microwave ablation. Methods: The fresh pig renal pelvis full filled with 30% diatrizoate meglumine and the dogs kidney taken arterial pyelography were both ablated with microwave. Dogs were divided into three groups: measuring temperature after ablation group, single point ablation both on the two kidneys group and double points ablation on unilateral kidney group. In measuring temperature after ablation group, DSA and pathology were performed immediately after ablation. In the other groups, DSA with blood and urine samplings were taken for routine tests including renal function right after the ablation and 10 days later. Results: Experiment in vitro showed conspicuous renal pelvic contraction and convolution. The group under power rate of 70, 3 min produced urine leak easily. Preliminary test in vivo with DSA showed the disappearance of local kidney blood supply. The residual renal function was related to areas of necrosis. Acute stage pathology revealed acute renal cortex medulla and pelvic cells injury. DSA of chronic stage showed no change in size of the area of ablation. The blood supply of necrotic areas was not restored. The residual kidney possessed the excretion contrast medium with no urine leaks. Upper pole of right kidney adhered with adjacent tissue, together with thickened covering. Pathology revealed fibrous proliferation around the coagulative necrosis. Conclusion: Microwave ablation can inactivate the local renal tissue, and, effectively preserve the big blood vessels and function of residual kidney. No urine leaks occurred in chronic stage but easily to produce adhesions with adjacent tissue. (authors)

  12. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich; Neufang, Achim

    2009-01-01

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  13. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Neufang, Achim [Johannes Gutenberg University Mainz, Department of Cardiothoracic and Vascular Surgery, Mainz (Germany)

    2009-12-15

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  14. Assessment of chronic thromboembolic pulmonary hypertension by three-dimensional contrast-enhanced MR angiography - comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ley, S.; Kauczor, H.U.; Kalden, P.; Pitton, M.B.; Thelen, M.; Mayer, E.; Laub, G.

    2000-01-01

    Purpose: This study compares contrast-enhanced 3D-MR angiography (MRA) of the pulmonary arteries with selective intraarterial DSA in patients with chronic thromboembolic pulmonary hypertension. Materials and methods: 20 patients preoperatively underwent a contrast-enhanced 3D-MRA of the pulmonary arteries at 1.5 T using the phased-array body coil. For MRA, we used a 3D-Flash-sequence after bolus timing. 2 radiologists analyzed the acquired image material in consensus with respect to the detection of central thromboembolic material and the visualization of the pulmonary arterial tree. Finally, the MR angiograms were compared with selective DSA images using surgical findings as the definitive standard. Results: MRA demonstrated central thromboembolic material, vessel cut-offs and abnormal proximal-to-distal tapering in all patients. Compared to DSA, MRA depicted the pulmonary vessels up to the segmental level in all cases, it was inferior to DSA in delineation of the subsegmental arteries (sensitivity 87%, specificity 100%). The central beginning of the thromboembolic occlusions seen at MRA corresponded to the beginning of the deobliteration procedure during pulmonary thromboendarterectomy in every case. (orig.) [de

  15. The DSA diagnosis, artery embolization combined with low dose of vasopressin infusion treatment for lower digestive tract hemorrhage

    International Nuclear Information System (INIS)

    Huang Guoxin; Dou Yongchong; Zhang Yanfang; Shen Xinying; Xu Jianmin

    2005-01-01

    Objective: To evaluate the clinical value of digital subtraction angiography (DSA) diagnosis and interventional treatment for lower digestive tract hemorrhage of unknown reasons. Methods: DSA was performed in 32 patients with unknown etiologic lower digestive tract hemorrhage. The locations and causes of hemorrhage were determined by angiography according to the demonstration of contrast medium extravasation, abnormal vasculature and tumor staining. Superselective arterial embolization was performed with retaining catheter of low dose vasopressin infusion for 12 hours of hemostasis. Results: Seventy-five percent of the lesions were identified by DSA with 2 cases of intestinal typhoid, 1 intestinal tuberculosis, 14 cases of vascular malformation and 7 cases of tumor. Hemostasis was succeeded in 20 of 24 patients. The rate of success was 83.3%. Conclusions: DSA and interventional therapy are of great value in diagnosing and treating patients with lower digestive tract hemorrhage of unknown reasons and even those undergone unsuccessful conservative treatment. Low dose vasopressin infusion through retained catheter is safe and efficient after superselective arterial embolization. (authors)

  16. Comparison of hepatic MDCT, MRI, and DSA to explant pathology for the detection and treatment planning of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Lauren M. Ladd

    2016-12-01

    Full Text Available Background/Aims The diagnosis and treatment plan for hepatocellular carcinoma (HCC can be made from radiologic imaging. However, lesion detection may vary depending on the imaging modality. This study aims to evaluate the sensitivities of hepatic multidetector computed tomography (MDCT, magnetic resonance imaging (MRI, and digital subtraction angiography (DSA in the detection of HCC and the consequent management impact on potential liver transplant patients. Methods One hundred and sixteen HCC lesions were analyzed in 41 patients who received an orthotopic liver transplant (OLT. All of the patients underwent pretransplantation hepatic DSA, MDCT, and/or MRI. The imaging results were independently reviewed retrospectively in a blinded fashion by two interventional and two abdominal radiologists. The liver explant pathology was used as the gold standard for assessing each imaging modality. Results The sensitivity for overall HCC detection was higher for cross-sectional imaging using MRI (51.5%, 95% confidence interval [CI]=36.2-58.4% and MDCT (49.8%, 95% CI=43.7-55.9% than for DSA (41.7%, 95% CI=36.2-47.3% (P=0.05. The difference in false-positive rate was not statistically significant between MRI (22%, MDCT (29%, and DSA (29% (P=0.67. The sensitivity was significantly higher for detecting right lobe lesions than left lobe lesions for all modalities (MRI: 56.1% vs. 43.1%, MDCT: 55.0% vs. 42.0%, and DSA: 46.9% vs. 33.9%; all P<0.01. The sensitivities of the three imaging modalities were also higher for lesions ≥2 cm vs. <2 cm (MRI: 73.4% vs. 32.7%, MDCT: 66.9% vs. 33.8%, and DSA: 62.2% vs. 24.1%; all P<0.01. The interobserver correlation was rated as very good to excellent. Conclusion The sensitivity for detecting HCC is higher for MRI and MDCT than for DSA, and so cross-sectional imaging modalities should be used to evaluate OLT candidacy.

  17. Comparison of remnant size in embolized intracranial aneurysms measured at follow-up with DSA and MRA.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-12-01

    The possibility of recanalization and the need for retreatment are the most important limitations of intracranial aneurysm embolization. The purpose of the study was to compare the size of aneurysm remnants measured at follow-up with three-dimensional digital subtracted angiography (3D-DSA) and magnetic resonance angiography (MRA). Twenty-six aneurysms were found incompletely occluded in 72 consecutively examined patients at a follow-up after 3 months. The diameters and volume of aneurysm remnants were compared between 3D-DSA, time-of-flight MRA (TOF-MRA), contrast-enhanced TOF-MRA (CE-TOF-MRA), and contrast-enhanced MRA (CE-MRA) at 1.5 T. There was a significant correlation between remnant volumes calculated based on 3D-DSA and all MRA modalities. The intraobserver variability of the measurements ranged from 3.4 to 4.1 % and the interobserver variability from 5.8 to 7.3 %. There were no significant differences in the variability between the techniques. The mean residual filling volume ranged from 16.3 ± 19.0 mm(3) in TOF-MRA to 30.5 ± 44.6 mm(3) in 3D-DSA (P < 0.04). Significant differences were found in the volumes measured with 3D-DSA and CE-MRA as compared to TOF-MRA and CE-TOF-MRA (P < 0.01). There was a moderate significant correlation between the residual filling and the relative error of measurement in the case of TOF-MRA and CE-TOF-MRA. TOF-MRA seems to underestimate the size of aneurysm remnants detected at follow-up and should not be used as a sole imaging method to decide on re-embolization.

  18. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  19. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  20. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  1. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)].

    Science.gov (United States)

    Kong, Gang; Dai, Dao-Qing; Zou, Lu-Min

    2008-07-01

    In order to remove the artifacts of peripheral digital subtraction angiography (DSA), an affine transformation-based automatic image registration algorithm is introduced here. The whole process is described as follows: First, rectangle feature templates are constructed with their centers of the extracted Harris corners in the mask, and motion vectors of the central feature points are estimated using template matching technology with the similarity measure of maximum histogram energy. And then the optimal parameters of the affine transformation are calculated with the matrix singular value decomposition (SVD) method. Finally, bilinear intensity interpolation is taken to the mask according to the specific affine transformation. More than 30 peripheral DSA registrations are performed with the presented algorithm, and as the result, moving artifacts of the images are removed with sub-pixel precision, and the time consumption is less enough to satisfy the clinical requirements. Experimental results show the efficiency and robustness of the algorithm.

  2. The MR imaging and DSA features and embolization therapy of spinal dural arteriovenous fistulae

    International Nuclear Information System (INIS)

    Zhang Hua; Hu Jinqing; Lin Dong; Wu Daming; Wang Dengbin; Yang Yanmin; Cheng Kemin

    2005-01-01

    Objective: To investigate the MR imaging and DSA features together with endovascular embolization of spinal dural arteriovenous fistulae (SDAVF). Methods: Twelve patients with SDAVF underwent both MR imaging and angiography of spinal cord, 4 of them received endovascular embolization. The imaging findings of MRI and angiography in all patients were analyzed. Results: Among 12 cases with SDAVF, 11 cases showed diffuse long T 2 signal, 2 cases demonstrated inhomogeneous maculate enhancement in the spinal cord and 6 cases revealed abnormal vessels in the dorsal spaces of spinal cord on MRI. Angiography of spinal cord showed orifices of all fistulae, draining veins, the extent of lesions, amount of feeding vessels and the angiographic features in all the 12 cases. 4 cases with embolization treatment showed improvement clinically. Conclusions: Angiography of spinal cord is the main method and MRI provides important assistance for diagnosing SDAVF while endovascular embolization is an effective method for the treatment. (authors)

  3. Intravenous spiral CT angiography for assessment before orthotopic liver transplantation: Comparison between tomography, MIP, 3-dimensional surface imaging and intraarterial DSA

    International Nuclear Information System (INIS)

    Hidajat, N.; Vogl, T.J.; Moeller, M.; Bechstein, W.O.; Felix, R.

    1996-01-01

    Purpose: To analyse the efficacy of intravenous spiral CT angiography (SCTA) for the evaluation before orthotopic liver transplantation (oLT) compared with DSA. Methods: Spiral CT was performed on 31 potential recipients of a liver graft in order to examine hepatic vessels, coeliac axis, splenic artery and superior mesenteric artery. The arterial vessels were reconstructed in 'Maximum Intensity Projection (MIP)' and 'Shaded Surface Display (SSD)'-technique. The axial images, MIP and SSD were compared in 25 patients with DSA with regard to the visualisation of the vascular anatomy, detectability of stenosis and vascular diameters. Results: The type of arterial liver supply could be determined via SCTA in all patients. Stenosis of the coeliac axis was seen in ten patients on the DSA, MIP and SSD and in eight patients on the axial images. Occlusion of the hepatic artery was clearly visualised in two patients on the DSA, axial images and MIP and in one patient on the SSD. There was no false positive diagnosis with SCTA. SSD was seen as the best technique to visualise the vessels without overshadowing. There were no significant differences between the diamters measured from the axial images, MIP and SSD images in transversal direction and the DSA images (p>0.05). Conclusion: SCTA is a greatly promising method for the imaging of vessels supplying the liver before oLT, and may convey more diagnostic information than DSA. (orig.) [de

  4. WDS/DSA Certification - International collaboration for a trustworthy research data infrastructure

    Science.gov (United States)

    Mokrane, Mustapha; Hugo, Wim; Harrison, Sandy

    2016-04-01

    , German Institute for Standardization (DIN) standard 31644, Trustworthy Repositories Audit and Certification (TRAC) criteria and the International Organization for Standardization (ISO) standard 16363. In addition, the Data Seal of Approval (DSA) and WDS have set up core certification mechanisms for trusted digital repositories in 2009, which are increasingly recognized as de facto standards. While DSA emerged in Europe in the Humanities and Social Sciences, WDS started as an international initiative with historical roots in the Earth and Space Sciences. Their catalogues of requirements and review procedures are based on the same principles of openness, transparency. A unique feature of the DSA and WDS certification is that it strikes a balance between simplicity, robustness and the effort required to complete. A successful international cross-project collaboration was initiated between WDS and DSA under the umbrella of the Research Data Alliance (RDA), an international initiative started in 2013 to promote data interoperability which provided a useful and neutral forum. A joint working group was established in early 2014 to reconcile and simplify the array of certification options and improve and stimulate core certification for scientific data services. The outputs of this collaboration are a Catalogue of Common Requirements (https://goo.gl/LJZqDo) and a Catalogue of Common Procedures (https://goo.gl/vNR0q1) which will be implemented jointly by WDS and DSA.

  5. Digital subtraction angiography (DSA) for acute pulmonary emboli

    International Nuclear Information System (INIS)

    Witte, H.; Grabbe, E.; Buecheler, E.

    1983-01-01

    The results of 49 DSAs (in 29 patients) are presented; these were performed for the diagnosis or follow-up of pulmonary emboli. The direct or indirect signs of pulmonary emboli, known to occur during conventional pulmonary angiography, were used as diagnostic criteria. In 47 examinations it was possible to make or to exclude the diagnosis unequivocally. The advantages of DSA make it desirable to use this method as the first form of examination in the diagnosis of acute, but not immediately life-threatening, pulmonary emboli. (orig.) [de

  6. Carotid DSA based CFD simulation in assessing the patient with asymptomatic carotid stenosis: a preliminary study.

    Science.gov (United States)

    Zhang, Dong; Xu, Pengcheng; Qiao, Hongyu; Liu, Xin; Luo, Liangping; Huang, Wenhua; Zhang, Heye; Shi, Changzheng

    2018-03-12

    Cerebrovascular events are frequently associated with hemodynamic disturbance caused by internal carotid artery (ICA) stenosis. It is challenging to determine the ischemia-related carotid stenosis during the intervention only using digital subtracted angiography (DSA). Inspired by the performance of well-established FFRct technique in hemodynamic assessment of significant coronary stenosis, we introduced a pressure-based carotid arterial functional assessment (CAFA) index generated from computational fluid dynamic (CFD) simulation in DSA data, and investigated its feasibility in the assessment of hemodynamic disturbance preliminarily using pressure-wired measurement and arterial spin labeling (ASL) MRI as references. The cerebral multi-delay multi-parametric ASL-MRI and carotid DSA including trans-stenotic pressure-wired measurement were implemented on a 65-year-old man with asymptomatic unilateral (left) ICA stenosis. A CFD simulation using simplified boundary condition was performed in DSA data to calculate the CAFA index. The cerebral blood flow (CBF) and arterial transit time (ATT) of ICA territories were acquired. CFD simulation showed good correlation (r = 0.839, P = 0.001) with slight systematic overestimation (mean difference - 0.007, standard deviation 0.017) compared with pressure-wired measurement. No significant difference was observed between them (P = 0.09). Though the narrowing degree of in the involved ICA was about 70%, the simulated and measured CAFA (0.942/0.937) revealed a functionally nonsignificant stenosis which was also verified by a compensatory final CBF (fronto-temporal/fronto-parietal region: 51.58/45.62 ml/100 g/min) and slightly prolonged ATT (1.23/1.4 s) in the involved territories, together with a normal left-right percentage difference (2.1-8.85%). The DSA based CFD simulation showed good consistence with invasive approach and could be used as a cost-saving and efficient way to study the relationship between

  7. DSA analysis of the normal and variant hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Lv Penghua; Wang Jie; Shi Haibing; Feng Yaoliang; Chen Huizhu; Chen Yuqin

    2005-01-01

    Objective: To observe and analyze the normal and variant hepatic arterial anatomy by DSA. Methods: One thousand and two hundreds patients with routine celiac and/or selective hepatic arteriography from November 1994 to March 2003 were retrospectively analyzed, some of them were further simultaneously undergone superior mesenteric arteriography, left gastric arteriography or inferior phrenic arteriography etc. Results: 873 (72.8%) patients had the standard hepatic arterial anatomy. 156(13.0%) patients had variant left hepatic arteries (LHAs), 120(10.0%) with variant right hepatic arteries (RHAs) and 21 (1.8%) of a variant anatomy involving both LHA and RHA. The common hepatic artery (CHA) of 1170 (97.5%) patients originated from the celiac artery. 92.0% proper hepatic artery (PHA) was the direct extension of CHA. The RHA was mainly (89.8%) derived from the PHA. There was some variation of the middle hepatic artery (MHA) with more than 62.2% arising from the LHA. The LHA was derived from the PHA (44.6%) or the RHA(30.2%) or other arteries (25.2%). Conclusions: The knowledge of normal and variant anatomy of hepatic vasculature by DSA may be very helpful for intervention therapy and hepatosurgery. (authors)

  8. Experiences from the LNPP-P and DSA review. Lessons learned from RBMK safety studies

    International Nuclear Information System (INIS)

    Mankamo, T.; Marttila, J.; Reponen, H.

    2000-09-01

    RBMK is the Russian acronym for 'Channelized Large Power Reactor'. The Soviet-designed RBMK plants deviate substantially from typical Western BWR or PWR plants. The safety of the RBMK plants has raised severe concerns since the major accident at Chernobyl Unit 4 in 1986. In addition, a fire destroyed the turbine hall of Chernobyl Unit 2 in 1991 resulting in a near-accident: the reactor cooling could only be maintained through improvised measures. Another well-known fire event is the control cable room fire at Ignalina Unit 2 in 1989, which led to a partial loss of the main control room functions. After the collapse of Soviet Union several multilateral safety programs were started to evaluate and improve the safety of the RBMK plants. A Probabilistic and Deterministic Safety Assessment (P and DSA) of the Leningrad Nuclear Power Plant (LNPP) Unit 2 was started in 1996. Phase 2 of the project was completed in January 1999. A Peer Review was performed by Russian and Western experts. This report describes the insights from the RBMK risk studies, especially from the LNPP P and DSA with emphasis on the deeper understanding of the risk-important design factors and identification of possible ways to increase safety. LNPP P and DSA has meant a significant progress in this respect. Despite of its certain limitations P and DSA Phase 2 could point out short-term measures, which substantially reduced the risk of identified weaknesses, mostly related to the reliability of the emergency feedwater function and its support systems. The findings of LNPP P and DSA and the review recommendations emphasise the extensions needed to the analysis scope. The spreading and other influences of fires and floods between connected spaces should be analysed because of incomplete separation and protection in these regards in the 16st generation RBMK plants. High priority should be given to the analysis of external hazards, which were found important at the Loviisa NPP on the Northern side of the

  9. Experiences from the LNPP-P and DSA review. Lessons learned from RBMK safety studies

    Energy Technology Data Exchange (ETDEWEB)

    Mankamo, T. [Avaplan Oy (Finland); Marttila, J.; Reponen, H. [Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2000-09-01

    RBMK is the Russian acronym for 'Channelized Large Power Reactor'. The Soviet-designed RBMK plants deviate substantially from typical Western BWR or PWR plants. The safety of the RBMK plants has raised severe concerns since the major accident at Chernobyl Unit 4 in 1986. In addition, a fire destroyed the turbine hall of Chernobyl Unit 2 in 1991 resulting in a near-accident: the reactor cooling could only be maintained through improvised measures. Another well-known fire event is the control cable room fire at Ignalina Unit 2 in 1989, which led to a partial loss of the main control room functions. After the collapse of Soviet Union several multilateral safety programs were started to evaluate and improve the safety of the RBMK plants. A Probabilistic and Deterministic Safety Assessment (P and DSA) of the Leningrad Nuclear Power Plant (LNPP) Unit 2 was started in 1996. Phase 2 of the project was completed in January 1999. A Peer Review was performed by Russian and Western experts. This report describes the insights from the RBMK risk studies, especially from the LNPP P and DSA with emphasis on the deeper understanding of the risk-important design factors and identification of possible ways to increase safety. LNPP P and DSA has meant a significant progress in this respect. Despite of its certain limitations P and DSA Phase 2 could point out short-term measures, which substantially reduced the risk of identified weaknesses, mostly related to the reliability of the emergency feedwater function and its support systems. The findings of LNPP P and DSA and the review recommendations emphasise the extensions needed to the analysis scope. The spreading and other influences of fires and floods between connected spaces should be analysed because of incomplete separation and protection in these regards in the 16st generation RBMK plants. High priority should be given to the analysis of external hazards, which were found important at the Loviisa NPP on the Northern

  10. DSA study of the effect of vasopressin on the small-bowel circulation before and after embolization

    International Nuclear Information System (INIS)

    Li Xueqin; Wang Qiaoxi; Guo Yuxin; Yang Xinhong; Hu Hongyao

    2001-01-01

    Objective: To study the effect of vasopressin (VS) on the small-bowel circulation and the safety of embolotherapy for the small intestinal hemorrhage by DSA. Methods: Ten dogs were divided into three groups. Vasa recta were ligated 30 min after VS infusion ended in group A (n = 4), and 2h after VS infusion ended in group B (n = 4), they were ligated without VS infusion in control group (n = 2). DSA were performed before and after VS infusion, before and after the ligation. The tested parts of intestine were resected to make the pathologic examination a week late. Results: All branches of mesenteric arteries contracted and the contrast developed light in the intestinal wall after VS infusion. Branches contraction recovered but the contrast developed still slight in the intestinal wall about 30 min after infusion ended. All manifestation of DSA recovered to normal 2h after infusion ended. In all groups, the blood vessel net can be seen but is fewer and scattered in the area of ligation. The collocate presented soon after the ligation. The pathologic examination proved that there was only mind mucosal ischemia in all groups. Conclusion: The repressive effect of VS to the circulation of intestine weakened and then disappeared rapidly after the infusion ended. VS infusion had no significant effect on the safety of embolotherapy for small intestinal bleeding when the infusion has been finished for more than 2hr. DSA can demonstrated the circulation state of the intestine before and after embolization

  11. Assistance Focus: Asia/Pacific Region; Clean Energy Solutions Center (CESC)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-05-11

    The Clean Energy Solutions Center Ask an Expert service connects governments seeking policy information and advice with one of more than 30 global policy experts who can provide reliable and unbiased quick-response advice and information. The service is available at no cost to government agency representatives from any country and the technical institutes assisting them. This publication presents summaries of assistance provided to governments in the Asia/Pacific region, including the benefits of that assistance.

  12. Phenol removal from wastewaters by electrochemical oxidation using boron doped diamond (BDD) and Ti/Ti{sub 0.7}Ru{sub 0.3}O{sub 2} DSA Registered-Sign electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Britto-Costa, P.H.; Ruotolo, L.A.M., E-mail: pluis@ufscar.br [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil). Dept. de Engenharia Quimica

    2012-10-15

    Industrial wastewater containing non-biodegradable organic pollutants consists of highly toxic effluents whose treatment is necessary due to environmental and economical restrictions. In order to treat these effluents, an electrochemical process using a dimensionally stable anode (DSA Registered-Sign ) and boron-doped diamond (BDD) electrode was studied. The performance of these electrodes for COD removal from aqueous phenol solution was evaluated in the absence and presence of different chloride concentrations. The results showed that DSA Registered-Sign could be successfully used to remove COD when high chloride concentration (3035 mg L{sup -1}Cl{sup -}) and mild current density are employed (50 mA cm{sup -2}). On the other hand, the presence of chloride did not have the same significant effect on the COD depletion rate using BDD; however, under mild conditions (50 mA cm{sup -2}, 0.190 m s{sup -1}), the addition of 607 mg L{sup -1} Cl{sup -} improved the COD removal by approximately 52% after 8 hours of electrolysis. The effect of current density (i) and flow velocity (v) were also studied, and it was verified that they have an important role on the process performance, especially when DSA Registered-Sign is used. (author)

  13. Intravenous digital subtraction angiography of the lower limbs combined with field movement (2-field DSA)

    International Nuclear Information System (INIS)

    Fritschy, P.; Terrier, F.

    1988-01-01

    We evaluated a bolus-chase technique designed to reduce the volume of contrast material and to shorten examination time during intravenous digital subtraction angiography (IV-DSA) of the lower limbs. With this technique, after a single injection of contrast material, two contiguous fields can be sequentially imaged (two-field DAS) using a step translated X-ray tube. 67 patients with peripheral vascular disease were studied. All examinations provided diagnostic information, so that in no instance additional intra-arterial injections were required. With the two-field DSA only 3.49 injections were needed in the average for five fields examined in each patient, resulting in a 30% reduction of contrast agent used. (orig.) [de

  14. The application of DSA bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Mao Xuequn; Zou Rong; Zhang Jian; Wang Meirong; Li Quan

    2010-01-01

    Objective: To retrospectively evaluate the digital subtraction angiography (DSA) bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus. Methods: From January 2004 to March 2010, DSA was performed in forty-five diabetes patients with suspicious vascular diseases of lower extremities. Among them, 24 cases (31 lower limbs)were examined with DSA bolus chase technology and the remaining 21 cases (21 lower limbs)were examined with traditional segmentational technique. The contrast dosage used in angiography, the total exposure time, the examination time and the imaging value for making diagnosis were analyzed and compared between two techniques. Results: For DSA bolus chase technology group, the contrast dosage used in angiography, the total exposure time and the examination time were 25.26 ml, 13.23 s and 37.26 min, respectively,with an average exposure of 101.65 pictures. For traditional segmentational technique group, the contrast dosage used in angiography, the total exposure time and the examination time were 130.00 ml, 52.38 s and 50.48 min, respectively, with an average exposure of 118.33 pictures. The percentage of high quality images in bolus chase technology group and in traditional segmentational technique group were 90.3% and 90.5%, respectively. All the images could meet the requirements for making a reliable diagnosis. Conclusion: Digital subtraction angiography by using bolus-chase technology can well demonstrate the vascular pathology of lower extremities caused by diabetes mellitus, obtain sufficient imaging information necessary for making a reliable diagnosis. DSA bolus chase technology is superior to traditional segmentational technique in shortening procedure time, reducing contrast medium dosage and decreasing radiation dose. (authors)

  15. Two-phase summation imaging using transvenous DSA in subclavian steal syndrome

    International Nuclear Information System (INIS)

    Arlart, I.P.

    1984-01-01

    A simple method is reported to obtain a two-phase summation image in subclavian steal syndrome using digital subtraction angiography (DSA) via selection of a mask during the early arterial phase and the contrast image during delayed retrograde filling of the ipsilateral vertebral artery and the postocclusive subclavian artery. The summation image results by employing replay of the stored image information. (orig.) [de

  16. Imaging of left ventricular wall motion via venous DSA

    International Nuclear Information System (INIS)

    Witte, G.; Roediger, W.; Buecheler, E.; Hamburg Univ.

    1986-01-01

    Until now, angiographical and nuclear medicine examination techniques for imaging left ventricular wall motion have been presenting with difficulties endemic to the methods themselves. For the first time in cardiological diagnostics, digital subtraction angiography (DSA) makes it possible to perform a fairly non-invasive examination with good spatial and temporal resolution. Functional analytic evaluation, however, still demands time-consuming, complicated post-processing. In this article we introduce a method that uses an additive window technique for the immediate generation of wall motion images. (orig.) [de

  17. Atomic layer deposition assisted pattern transfer technology for ultra-thin block copolymer films

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wenhui; Luo, Jun; Meng, Lingkuan; Li, Junjie; Xiang, Jinjuan; Li, Junfeng; Wang, Wenwu; Chen, Dapeng; Ye, Tianchun; Zhao, Chao

    2016-08-31

    As an emerging developing technique for next-generation lithography, directed self-assembly (DSA) of block copolymer (BCP) has attracted numerous attention and has been a potential alternative to supplement the intrinsic limitations of conventional photolithography. In this work, the self-assembling properties of a lamellar diblock copolymer poly(styrene-b-methylmethacrylate) (PS-b-PMMA, 22k-b-22k, L{sub 0} = 25 nm) on Si substrate and an atomic layer deposition (ALD)-assisted pattern transfer technology for the application of DSA beyond 16/14 nm complementary metal oxide semiconductor (CMOS) technology nodes, were investigated. Firstly, two key processing parameters of DSA, i.e. annealing temperatures and durations of BCP films, were optimized to achieve low defect density and high productivity. After phase separation of BCP films, self-assembling patterns of low defect density should be transferred to the substrate. However, due to the nano-scale thickness and the weak resistance of BCP films to dry etching, it is nearly impossible to transfer the BCP patterns directly to the substrate. Therefore, an ALD-based technology was explored in this work, in which deposited Al{sub 2}O{sub 3} selectively reacts with PMMA blocks thus hardening the PMMA patterns. After removing PS blocks by plasma etching, hardened PMMA patterns were left and transferred to underneath SiO{sub 2} hard mask layer. Using this patterned hard mask, nanowire array of 25 nm pitch were realized on Si substrate. From this work, a high-throughput DSA baseline flow and related ALD-assisted pattern transfer technique were developed and proved to have good capability with the mainstream CMOS technology. - Highlights: • Optimization on self-assembly process for high productivity and low defectivity • Enhancement of etching ratio and resistance by atomic layer deposition (ALD) • A hard mask was used for pattern quality improvement and contamination control.

  18. Oxidation assisted intergranular cracking under loading at dynamic strain aging temperatures in Inconel 718 superalloy

    Energy Technology Data Exchange (ETDEWEB)

    Rezende, M.C., E-mail: monica_crezende@hotmail.com [Universidade Federal do Rio de Janeiro, Departamento de Engenharia Metalúrgica e de Materiais, C.P. 68505, Rio de Janeiro 21945-970 (Brazil); Araújo, L.S.; Gabriel, S.B. [Universidade Federal do Rio de Janeiro, Departamento de Engenharia Metalúrgica e de Materiais, C.P. 68505, Rio de Janeiro 21945-970 (Brazil); Dille, J. [Université Libre de Bruxelles, 4MAT Department, Av. F. Roosevelt 50, C.P. 194/03, Brussels (Belgium); Almeida, L.H. de [Universidade Federal do Rio de Janeiro, Departamento de Engenharia Metalúrgica e de Materiais, C.P. 68505, Rio de Janeiro 21945-970 (Brazil)

    2015-09-15

    Highlights: • Mechanical properties are controlled by DSA, precipitation hardening and OAIC. • Between 600 and 700 °C the critical strain for serrations increases with temperature. • This is related to the consumption of matrix elements (especially Nb: for γ′ and γ″). • A reduction in ductility occurs (related to the OAIC) when the DSA is no longer effective. • This reduction is accompanied by an increase in intergranular brittle fracture. - Abstract: It is well established that 718 superalloy exhibits brittle intergranular cracking when deformed under tension at temperatures above 600 °C. This embrittlement effect is related with grain boundary penetration by oxygen (Oxygen Assisted Intergranular Cracking – OAIC). Simultaneously, impacting on its mechanical properties, the precipitation of coherent γ′ and γ″ phases occur above 650 °C and Dynamic Strain Aging (DSA) occurs in the temperature range between 200 and 800 °C. Although literature indicates that OAIC is the mechanism that controls mechanical properties at high temperatures, its interactions with DSA and precipitation are still under discussion. The objective of this work is to investigate the interactions between the embrittlement phenomena (OAIC and DSA) and the hardening mechanism of γ′ and γ″ precipitation on the mechanical properties of an annealed 718 superalloy. Tensile tests were performed at a strain rate of 3.2 × 10{sup −4} s{sup −1} under secondary vacuum, in temperatures ranging from 200 to 800 °C. Fracture surfaces were observed by scanning electron microscopy (SEM) and precipitation by transmission electron microscopy (TEM). The effect of DSA and precipitation on the strength and of OAIC on the ductility was verified.

  19. Clinical value of the assistant interventional embolization in treatment of juvenile nasopharyngeal angiofibroma

    International Nuclear Information System (INIS)

    Xu Guobin; Zhou Shi; Liu Junfang; Hu Jinxiang; Long Qingyun

    2007-01-01

    Objective: To study the application of the assistant digital subtraction angiography (DSA) with selective intra-arterial embolization in comprehensive treatment of juvenile nasopharyngeal angiofibroma. Methods: Among 17 patients with juvenile nasopharyngeal angiofibroma confirmed by surgery and biopsy from February 2000 to June 2005, 13 cases underwent DSA examination and selective intra-arterial embolization on 1-4 days before surgical operation, and 4 cases with uncontrollable epistaxis through conventional therapy were carried out urgent DSA and embolization as well as surgical operation on a scheduled day. Angiographic manifestations and hemostatic effects and impacts in surgical operation were observed. Results: The extent and blood supply of lesions and the features of feeding artery were clearly demonstrated by DSA. Supplying vessel was mainly maxillary artery originating from external caroted artery in 16 cases, and double supplying vessels from ramus of internal and external carotid arteries in 1 case. In general, the higher the nasopharyngeal angiofibroma grade was the more supplying branches would exist. As for epistaxis patients, the number of the presence of irregular distal vessels and the punctiform extravasation of contrast media were displayed in positive proportion. No severe complications occurred and active bleeding was stopped after embolization and furthermore with less blood loss during surgical operation statistically about 280-1600 ml (460±255.5). Conclusions: DSA examination and selective arterial embolization can not only present more accurate important clinical imaging features but also in favour of stop bleeding and enhance surgical outcomes for patients with nasopharyngeal angiogibroma. (authors)

  20. The dose-area product in DSA

    International Nuclear Information System (INIS)

    Gfirtner, H.

    1995-01-01

    In DSA, the dose-area product shows a very good correlation with the maximum incidence dose. It may therefore serve as a reliable basis for the assessment of radiation doses to patients. The dose-area product is also a useful tool for the detection pf peak shifts in the radiation curves for certain investigations. In view of the considerable scatter of the values for the dose-area product these must, however, be subjected to an additional statistical analysis. Provided that this rule is observed, the dose-area product will considerably gain in importance for the monitoring of radiation exposures of patients. A very noteworthy learning effect could be achieved, if it would be made mandatory for those statistical analyses to be carried out not only on an investigation-specific but also an investigator-specific basis. The latter is particularly true of teaching hospitals. (orig./VHE) [de

  1. Personalized Monitoring and Assistive Systems: Case Study of Efficient Home Solutions.

    Science.gov (United States)

    Lhotska, Lenka; Doležal, Jaromír; Adolf, Jindřich; Potůček, Jiří; Křížek, Miroslav; Chbani, Baha

    2018-01-01

    The rapid emergence and proliferation of connected medical devices and their application in healthcare are already part of the Healthcare Internet of Things (IoT) - as this area started to be named. Their true impact on patient care and other aspects of healthcare remains to be seen and is highly dependent on the quality and relevancy of the data acquired. There is also the trend of application of IoT in telemedicine and home care environment. Currently many research groups focus on design and development of various solutions that can assist elderly and handicapped people in their home environment. However, many of these solutions are sophisticated and require advanced users that are able to control the device, handle error states and exceptions. They are frequently using expensive technologies that are good for laboratory environment but they are not affordable for many elderly or handicapped persons. In the paper we will analyze the current situation, present identified needs of elderly population and propose potential solutions. On a case study of efficient home solution of a personalized and assistive system we will show possibilities of technologically simple solutions using off-the-shelf devices and elements.

  2. A comparative study of pulmonary hypoperfusion secondary to cancerous invasion of central pulmonary artery in lung cancer with CT and DSA

    International Nuclear Information System (INIS)

    Guo Dajing; Miao Jingtao; Lu Wusheng; Bai Hongli

    2003-01-01

    Objective: To study CT features of pulmonary hypoperfusion in lung cancer with cancerous invasion of central pulmonary artery (CICPA) and the diagnostic value of CT. Methods: The pre-operative pulmonary DSA and contrast-enhanced spiral CT (including HRCT) findings in 20 cases of lung cancer with CICPA were carried out prospectively and comparatively. On DSA and CT, the distribution and quantitative variation of subpleural terminal pulmonary arterioles (pulmonary vessel signs), the filling degree of lung capillary, the post-contrast density changes of lung parenchyma, and the fluctuations of the time-density curve (pulmonary parenchymal signs) were blindly observed. The CT and DSA findings and their consistence were analyzed statistically. The diagnostic values of CT in secondary pulmonary hypoperfusion in lung cancer with CICPA were evaluated. Results: There were 30 lobar arteries with cancerous invasion among the 20 cases and 90% (27/30) of them presented pulmonary hypoperfusion on DSA. For diagnosing pulmonary hypoperfusion, CT had a sensitivity of 78%(21/27), a specificity of 100% (3/3), and an accuracy of 80%(24/30). There were no statistical correlation between pulmonary hypoperfusion and the degree of central pulmonary artery (CPA) stenosis (r s =0.40, P=0.073). Pulmonary vessel signs on CT had a good consistence with that on DSA (Kappa=0.69, P<0.001), while that of pulmonary parenchymal signs was lower (Kappa=0.37, P=0.011). Conclusion: Pulmonary hypoperfusion is one of the common findings in lung cancer with CICPA. CT is of great value in qualitative diagnosis on it, while for quantitative diagnosis, its value is limited to a certain degree

  3. DSA-guided embolization in establishing different canine spinal cord ischemia models and relevant diffusion-weighted imaging study

    International Nuclear Information System (INIS)

    Zhang Jingsong; Sun Lijun; Huan Yi; He Hongde; Zhang Xuexin; Zhao Haitao; Zhang Jing; Zhang Xijing

    2006-01-01

    Objective: To evaluate DSA-guided embolization in establishing different spinal cord ischemia models of canine and relevant diffusion-weighted imaging (DWI) application. Methods: Nine canines were randomly divided into three groups with different matching of lipiodol and diatrizoate meglumine which were injected into bilateral intercostal arteries at 9-11 level guided by DSA monitor. Then observe the changes of motor function and pathologic findings, especially perform routine MRI and DWI by a 1.5 T MR system. Results: Except one case, 8 embolization models were established successfully. Among three groups, slight-group got slight injury and muscle power was about 3-5 grade and range of injury was about two vertebra distance; medium-group presented obvious paraplegia and muscle power was 0-1 grade and range of injury was between 3-4 vertebra distance; severe-group showed greater severity and larger range of injury. All lesions presented high signals at routine MRI and DWI. Conclusion: Using different matching of lipiodol and diatrizoate meglumine can establish different spinal cord ischemia models of canine by DSA- guided embolization and DWI can be performed successfully by 1.5 T MR system, which may be a good method for advanced study of spinal cord ischemia. (authors)

  4. Carbon dioxide DSA: An alternative to nonionic contrast material

    International Nuclear Information System (INIS)

    Hawkins, I.F.; Siragusa, R.; Mietling, S.; Storm, B.; Hawkins, M.; Hirko, R.; Colella, J.

    1987-01-01

    Over the past 6 years the authors have used CO/sub 2/ with DSA as a contrast agent in over 400 cases for arteriography, venography, portography, and opacification of the biliary and urinary tree. The compressibility of the CO/sub 2/ made consistent delivery difficult. Two injectors were designed which reliably delivered the exact amount of the inexpensive CO/sub 2/ which is required. This improved vascular opacification, collateral filling, and tumor AV shunting without any complications or discomfort. Selective renal artery injections were performed in over 20 patients with renal failure without any increase in creatinine. The authors' experience with animals, patients, and the new injectors are illustrated

  5. Follow-up of intracranial aneurysms treated by a WEB flow disrupter: a comparative study of DSA and contrast-enhanced MR angiography.

    Science.gov (United States)

    Mine, Benjamin; Tancredi, Illario; Aljishi, Ali; Alghamdi, Faisal; Beltran, Margarita; Herchuelz, Maxime; Lubicz, Boris

    2016-06-01

    To compare contrast-enhanced MR angiography (CE-MRA) and DSA for the follow-up of intracranial aneurysms (IAs) treated with the Woven EndoBridge embolization system DL (WEB DL; Sequent Medical, Aliso Viejo, California, USA). We retrospectively identified all patients treated with a WEB DL between November 2010 and February 2013 in 2 hospitals. The IA occlusion was graded on follow-up CE-MRA and DSA by 4 independent readers and by 2 readers reaching a consensus, respectively. Interobserver agreement for MRA and intertechnique agreement was evaluated by calculating linear weighted κ. Fifteen patients with 16 IAs were included. Mean delay between MRA and DSA was 2 months (range 0-16 months). Interobserver agreement for MRA was substantial to almost perfect (κ=0.686-0.921; mean κ=0.809). Intertechnique agreement was moderate to substantial (κ=0.579-0.724; mean κ=0.669). Only three out of five inadequately occluded IAs were detected by MRA. CE-MRA is a useful tool for the follow-up of IAs treated with a WEB DL. However, early follow-up with DSA remains mandatory to detect inadequately occluded IAs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Diagnosis of renal artery stenosis : spiral CTA vs. IA-DSA

    International Nuclear Information System (INIS)

    Kim, Tae Sung; Chung, Jin Wook; Park, Jae Hyung; Kim, Seung Hyup; Yeon, Kyung Mo; Han, Man Chung

    1996-01-01

    To evaluate the accuracy of spiral CT angiography(CTA) in the demonstration of accessory or multiple renal arteries and renal artery stenosis. We prospectively performed CTA in 50 patients (24 males and 26 females) between nine and 77 years old (mean 39.3) in whom renovascular hypertension was suspected (n=32), or who were potential renal donors (n=18). Within two days of CTA, intraarterial digital subtraction angiography(IA-DSA) was performed. Both spiral CTA and IA-DSA images were blindly compared by two radiologists with respect to the number of accessory renal arteries and the location and severity of renal artery stenosis. The severity of renal arterial stenosis was graded with a five-point scale (grades 0-4). CTA demonstrated 26 of total 27 accessory renal arteries (detection rate=96.5%). For the diagnosis of grade 2-4 stenosis (≥50% stenosis) (n=40 of a total of 127 renal arteries), the sensitivity, specificity, and accuracy of CTA were 90%, 96.5%, and 94.5%, respectively. For the detection of grade 3-4 stenoses (≥75% stenosis) (n=33), the sensitivity, specificity, and accuracy of CTA were 87.9%, 98.9%, and 96.1%, respectively. For the detection of grade 3-4 stenoses in the main renal artery (n=27), the sensitivity, specificity, and accuracy of CTA were 96.3%, 100%, and 99.0%, respectively. Spiral CTA is a reliable and accurate screening modality for the evaluation of renal artery in patients suspected to be suffering from renovascular hypertension, or who are potential renal donors

  7. Effect of dynamic strain ageing on the environmentally assisted cracking of low-alloy steels oxygenated high-temperature water

    International Nuclear Information System (INIS)

    Devrient, B.; Roth, A.; Kuester, K.; Ilg, U.; Widera, M.

    2007-01-01

    The plastic deformation behavior of low-alloy steels (LAS) is significantly influenced by their individual susceptibility to dynamic strain ageing (DSA). Interstitial atoms of nitrogen (N) or carbon (C) in the steel matrix can change the mechanical properties like ductility and strength by interaction with moving dislocations during plastic deformation. The degree of DSA is depending on temperature and strain rate during plastic deformation. Under critical parameter combinations strength increases while ductility decreases. Furthermore, the interaction of dislocations and interstitial atoms can lead to a localization of plastic deformation, which results in planar gliding processes. Shear bands in LAS types with a high susceptibility to DSA show significantly higher slip steps during plastic deformation as compared to heats with low susceptibility to DSA. Since the basic mechanism of environmentally-assisted cracking (EAC) of LAS in high-temperature water (HTW) environment is slip-step-dissolution, slip behavior is of crucial nature for the kinetics of crack initiation and crack growth. Therefore, a program concerning deformation behavior, slip characterization regarding distribution and size, and behavior in oxygenated HTW environment was performed. Analysis of slip steps by advanced techniques for surface morphology investigation showed that the maximum height of slip steps is in the range of freshly formed magnetite layers on LAS in oxygenated HTW environment. This supports the active effect of localized deformation on EAC in LAS types of high susceptibility to DSA. The exposure to oxygenated HTW environment with additional mechanical loading under critical combinations of temperature and strain rate of different LAS types with high, intermediate and low susceptibility to DSA in Slow Strain Rate Tensile-tests (SSRT) showed preferential crack initiation in the areas of coarse shear bands due to localized deformation. Furthermore, a continuous transition of the

  8. Hemodynamic study of cervical carotid arteries using DSA

    International Nuclear Information System (INIS)

    Kumashiro, Masayuki; Araki, Osamu; Matsunaga, Morio; Shigeyasu, Makio

    1986-01-01

    Although intravenous digital subtraction angiography (IVDSA) has been widely utilized as a means of morphological examination for the detection of intracranial or extracranial vascular lesions, it has thus for contributed little to quantitative assessment in hemodynamics. In the present study, a fundamental analysis of the hemodynamics on the cervical carotid artery was performed with a relative perfusion efficiency (Rath et al., 1979). This was not related to the measurement of time, such as the mean transit time, but was based on Sapirstein's principle. After the intravenous administration of the contrast material, dynamic DSA was performed using our equipment, Shimadzu DAR-100. After setting the region of interest in common carotid arteries on DSA images by means of a microdensitometer (Sakura PDS-15) combined with a computer (NEC ACOS-460), time-density curves were obtained on both sides. Thereafter, the RPE was calculated as a ratio of two integrals from the zero time to the earlier peak time of the time-density curves with respect to the time. The flow model with the hydro-dynamic system was used to detect the relationship between the RPEs and the ratios of the actual flows in the system. The results of this experiment showed a high correlation between the RPEs and the flows (r = 0.85, p < 0.001). In normal subjects (n = 28), the mean of the RPEs was 1.07 ± 0.27 (S.D.). The RPEs showed significantly lower values in the 5 patients with severe stenosis of the internal carotid artery (0.76 ± 0.15, p < 0.02), as well as even more significantly lower values in the 9 patients with a complete occlusion of the internal carotid artery (0.64 ± 0.19, p < 0.001). The RPE measurement with IVDSA has been shown to be useful for recognizing the cervical hemodynamic changes in patients with occlusive cervicovascular disease. (author)

  9. Successive approximation algorithm for cancellation of artifacts in DSA images

    International Nuclear Information System (INIS)

    Funakami, Raiko; Hiroshima, Kyoichi; Nishino, Junji

    2000-01-01

    In this paper, we propose an algorithm for cancellation of artifacts in DSA images. We have already proposed an automatic registration method based on the detection of local movements. When motion of the object is large, it is difficult to estimate the exact movement, and the cancellation of artifacts may therefore fail. The algorithm we propose here is based on a simple rigid model. We present the results of applying the proposed method to a series of experimental X-ray images, as well as the results of applying the algorithm as preprocessing for a registration method based on local movement. (author)

  10. The effect of the signal-to-noise ratio and window width on image information in intravenous DSA of various vascular regions

    International Nuclear Information System (INIS)

    Arlart, I.P.; Ertel, R.; Siemens A.G., Erlangen

    1986-01-01

    The diagnostic quality of DSA images depends on numerous factors related to the apparatus and the technique of examination. An improvement in image can be brought about by correct choice of the mask and injected frames, by subsequent correct manipulation of the images and by the choice of the signal-to-noise ratio and window width. In the present study, the effect of these factors was demonstrated on image quality of venous DSA studies in various vascular regions. Practical advice is given for the examination of particular regions and for various diagnostic problems. (orig.)

  11. Brain arteriovenous malformation diagnosis: value of time-resolved contrast-enhanced MR angiography at 3.0T compared to DSA

    International Nuclear Information System (INIS)

    Machet, A.; Kadziolka, K.; Robin, G.; Lanoix, O.; Pierot, L.; Portefaix, C.

    2012-01-01

    This study was conducted in order to evaluate the value of time-resolved contrast-enhanced magnetic resonance angiography (TR-CE-MRA) with a 3.0-T magnetic field compared to digital subtraction angiography (DSA) as the reference standard for the diagnosis of brain arteriovenous malformation (bAVM). Nineteen patients with 19 angiographically confirmed untreated bAVM were investigated with both DSA and TR-CE-MRA for the initial diagnosis. Examinations were compared by two independent readers. Interobserver agreement and intermodality agreement with respect to nidus size, arterial feeders, and venous drainage were determined using the K statistic test. Also, the quality of the TR-CE-MRA images was evaluated. Seventeen of the 19 bAVM (89.5%) detected with DSA were diagnosed with TR-CE-MRA. Interobserver agreement for TR-CE-MRA was good for nidus size, venous drainage, and arterial feeders (K = 0.75, 95% CI 0.50-1.00; K = 0.77, 95% CI 0.54-1.00; and K = 0.80, 95% CI 0.59-1.00 respectively). Intermodality agreement was good for nidus size and venous drainage (K = 0.75, 95% CI 0.49-1.00 and K = 0.77, 95% CI 0.54-1.00, respectively) and moderate for arterial feeders (K = 0.44, 95% CI 0.17-0.70). TR-CE-MRA at 3.0 T has a good sensitivity for bAVM detection and good agreement with DSA for determining nidus size and the type of venous drainage, suggesting that TR-CE-MRA is potentially a reliable tool for the diagnosis and assessment of bAVMs. However, it still suffers from low spatial resolution and vessel superposition, making differentiation of the arterial feeders of the nidus difficult at times. (orig.)

  12. Introduction to the principles of Digital Subtraction Angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Kaplanis, P [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus)

    1998-12-31

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author). 5 refs, 3 figs.

  13. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  14. Assessment and treatment planning of lateral intracranial dural arteriovenous fistulas in 3 T MRI and DSA: A detailed analysis under consideration of time-resolved imaging of contrast kinetics (TRICKS) and ce-MRA sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ertl, L.; Brueckmann, H.; Patzig, M.; Brem, C.; Forbrig, R.; Fesl, G. [Ludwig-Maximilians-University, Grosshadern Campus, Department of Neuroradiology, Institute of Clinical Radiology, Munich (Germany); Kunz, M. [Ludwig-Maximilians-University, Grosshadern Campus, Department of Neurosurgery, Munich (Germany)

    2016-12-15

    The current gold standard in the assessment of lateral intracranial dural arteriovenous fistulas (LDAVF) is digital subtraction angiography (DSA). However, magnetic resonance imaging (MRI) is a non-invasive emerging tool for the evaluation of such lesions. The aim of our study was to compare the DSA to our 3 T MR-imaging protocol including a highly spatial resolved (ce-MRA) and a temporal resolved (''time-resolved imaging of contrast kinetics'', TRICKS) contrast-enhanced MR angiography to evaluate if solely DSA can remain the gold-standard imaging modality for the treatment planning of LDAVF. We retrospectively reviewed matched pairs of DSA and 3 T MRI examinations of 24 patients with LDAVF (03/2008-04/2014) by the same list of relevant criteria for an endovascular LDAVF treatment planning. In particular, we determined intermodality agreement for the Cognard classification, the identifeication of arterial feeders, and the detailed assessment of each venous drainage pattern. Intermodality agreement for the Cognard classification was excellent (k = 1.0). Whereas MRI failed in identifying small arterial feeders, it was superior to the DSA in the assessment of the sinus and the venous drainage pattern. The combination of MRI and DSA is the new gold standard in LDAVF treatment planning. (orig.)

  15. Just in Time DSA-The Hanford Nuclear Safety Basis Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Olinger, S. J.; Buhl, A. R.

    2002-02-26

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safety Basis Requirements (the Rule) in January 2001 imposed the requirement that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSA that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: compliance with the Rule; a ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD&D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD&D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex.

  16. Just in Time DSA-The Hanford Nuclear Safety Basis Strategy

    International Nuclear Information System (INIS)

    Olinger, S. J.; Buhl, A. R.

    2002-01-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safety Basis Requirements (the Rule) in January 2001 imposed the requirement that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSA that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: compliance with the Rule; a ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD and D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD and D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex

  17. Automated tracking of the vascular tree on DSA images

    International Nuclear Information System (INIS)

    Alperin, N.; Hoffmann, K.R.; Doi, K.

    1990-01-01

    Determination of the vascular tree structure is important for reconstruction of three-dimensional vascular tree from biplane images, for assessment of the significance of a lesion, and for planning treatment for arteriovenous malformation. To automate these analyses, the authors of this paper are developing a method to determine the vascular tree structure from digital subtraction angiography (DSA) images. The authors have previously described a vessel tracking method, based on the double-square-box technique. To improve the tracking accuracy, they have developed and integrated with the previous method a connectivity test and guided-sector-search technique. The connectivity test, based on region growing techniques, eliminates tracking across nonvessel regions. The guided sector-search method incorporates information from a larger are of the image to guide the search for the next tracking point

  18. Evaluation of the carotid and vertebral arteries: comparison of 3D SCTA and IA-DSA-work in progress

    International Nuclear Information System (INIS)

    Seemann, M.D.; Minx, C.; Heuck, A.; Reiser, M.F.; Englmeier, K.H.; Schuhmann, D.R.G.; Fuerst, H.

    1999-01-01

    Objective: The purpose of this study was to develop a method for three-dimensional (3D) visualization of the whole vascular system of the carotid and vertebral arteries using spiral computed tomographic angiography (SCTA), that allows accurate, qualitative and quantitative evaluation, of anatomical abnormalities, including detection of additional lesions, and estimation of degree of stenosis. Materials and methods: Fifteen patients with anatomical and pathological abnormalities of the arterial vascular system detected by color-coded duplex ultrasound were studied using intraarterial digital subtraction angiography (IA-DSA) with aortic arch injection, and SCTA. The carotid and vertebral arteries were segmented using an interactive threshold interval density volume-growing method and visualized with a color-coded shaded-surface display (SSD) rendering method. The adjacent bone structures were visualized using a transparent volume rendering method. Results: In all cases, the entire volume of the vascular system of the carotid and vertebral arteries could be visualized on SCTA, and the anatomical and pathological abnormalities on 3D SCTA correlated well with that seen on IA-DSA. Conclusion: Results of 3D SCTA had a high degree of correlation with results of IA-DSA in the evaluation of the vascular system of the carotid and vertebral arteries. The 3D SCTA with a subsecond spiral CT scanner is useful for the visualization of anatomical and pathological abnormalities in the circulation in the carotid and vertebral arteries and offer a promising minimally invasive alternative compared with other diagnostic procedures. (orig.) (orig.)

  19. Clinical effectiveness of DSA-guided foam sclerotherapy for varicose veins of lower limbs

    International Nuclear Information System (INIS)

    Fu Jianhua; He Xu; Chen Guoping; Gu Jianping; Wang Yafei

    2011-01-01

    Objective: To investigate the clinical effect of DSA-guided foam sclerotherapy for varicose veins of lower limbs. Methods: A total of 25 diseased limbs in 20 patients with varicose veins were treated with foam sclerotherapy. The patients were followed up for six months. Sodium morrhuate, used as the sclerosant, was foamed with air by using Tessari's method, with liquid-gas ratio of 1 : 4. The clinical effectiveness was estimated by CEAP, clinical signs and symptoms. Results: A total of 25 limbs in 20 patients with varicose veins were successfully treated with foam sclerotherapy. The technical success rate was 100%. No serious complications such as pulmonary embolism occurred. Phlebitis was observed in two cases at 2 days 4 days after foam sclerotherapy respectively which was relieved after anti-inflammatory medication for 3 days. At the time of discharge, excellent result was seen in 12 (48%) limbs, good effect in 13 (52%) limbs. The total effective rate was 100%. Six months after the treatment, excellent effect was obtained in 15 (60%) limbs and good effect was seen in 10 (40%) limbs. The total effective rate was 100%. Conclusion: DSA-guided foam sclerotherapy is a safe, effective and micro-invasive treatment for varicose veins of lower limbs with high technical success rate, although the long-term clinical effect needs to be further evaluated. (authors)

  20. Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA

    International Nuclear Information System (INIS)

    Ramgren, Birgitta; Siemund, Roger; Cronqvist, Mats; Undren, Per; Holtaas, Stig; Nilsson, Ola G.; Larsson, Elna-Marie

    2008-01-01

    The purpose of this prospective study was to compare 3T and 1.5T magnetic resonance angiography (MRA) with digital subtraction angiography (DSA) for the follow-up of endovascular treated intracranial aneurysms to assess the grade of occlusion. Thirty-seven patients with 41 aneurysms who had undergone endovascular treatment with detachable coils were included. MRA was performed on the same day using an eight-channel sensitivity encoding head-coil with 3D axial inflow technique. At 3T, a contrast-enhanced transverse 3D fast gradient echo acquisition was also performed. Most patients underwent DSA the following day. MRA scans and DSA were classified first independently by two neuroradiologists and an interventional neuroradiologist. Secondly, a consensus was done. Source images, maximum intensity projection, multiplanar reconstruction and volume rendering reconstructions were used for MRA evaluations. A modification of the Raymond classification, previously used for DSA evaluation of recanalization, was used. Statistical comparison of the consensus showed that 3T MRA with 3D axial inflow technique had better agreement with DSA (κ = 0.43) than 1.5T MRA(κ = 0.21) and contrast-enhanced MRA (CE-MRA) at 3T (κ = 0.17). The susceptibility artefacts from the coil mesh were significally smaller at 3T (p = 0.002-0.007) than at 1.5T. 3T MRA, using a sensitivity encoding head-coil, showed better agreement with DSA than 1.5T and CE-MRA at 3T for evaluation of aneurysms treated with endovascular coiling. (orig.)

  1. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  2. DSA lifetime measurements in 21Ne at high recoil velocity

    International Nuclear Information System (INIS)

    Grawe, H.; Heidinger, F.; Kaendler, K.

    1977-01-01

    States in 21 Ne up to 5 MeV excitation energy have been populated using the inverted reaction 2 H( 20 Ne,pγ). The Doppler shift attenuation (DSA) analysis of the pγ coincidence spectra taken in a Ge(Li) detector at 45 0 and 135 0 and an annular silicon surface barrier detector near 0 0 yielded the lifetimes of 8 states in 21 Ne. Due to the large recoil of vi/c approximately equal to 4% three new lifetimes were determined for the short lived levels at 2.80, 4.68 and 4.73 MeV, namely 10 +- 4 fs, 16 +- 4 fs and 10 +- 4 fs, respectively. The results are compared with rotational and shell model calculations. (orig.) [de

  3. Solution of the within-group multidimensional discrete ordinates transport equations on massively parallel architectures

    Science.gov (United States)

    Zerr, Robert Joseph

    2011-12-01

    The integral transport matrix method (ITMM) has been used as the kernel of new parallel solution methods for the discrete ordinates approximation of the within-group neutron transport equation. The ITMM abandons the repetitive mesh sweeps of the traditional source iterations (SI) scheme in favor of constructing stored operators that account for the direct coupling factors among all the cells and between the cells and boundary surfaces. The main goals of this work were to develop the algorithms that construct these operators and employ them in the solution process, determine the most suitable way to parallelize the entire procedure, and evaluate the behavior and performance of the developed methods for increasing number of processes. This project compares the effectiveness of the ITMM with the SI scheme parallelized with the Koch-Baker-Alcouffe (KBA) method. The primary parallel solution method involves a decomposition of the domain into smaller spatial sub-domains, each with their own transport matrices, and coupled together via interface boundary angular fluxes. Each sub-domain has its own set of ITMM operators and represents an independent transport problem. Multiple iterative parallel solution methods have investigated, including parallel block Jacobi (PBJ), parallel red/black Gauss-Seidel (PGS), and parallel GMRES (PGMRES). The fastest observed parallel solution method, PGS, was used in a weak scaling comparison with the PARTISN code. Compared to the state-of-the-art SI-KBA with diffusion synthetic acceleration (DSA), this new method without acceleration/preconditioning is not competitive for any problem parameters considered. The best comparisons occur for problems that are difficult for SI DSA, namely highly scattering and optically thick. SI DSA execution time curves are generally steeper than the PGS ones. However, until further testing is performed it cannot be concluded that SI DSA does not outperform the ITMM with PGS even on several thousand or tens of

  4. Optimal space-energy splitting in MCNP with the DSA

    International Nuclear Information System (INIS)

    Dubi, A.; Gurvitz, N.

    1990-01-01

    The Direct Statistical Approach (DSA) particle transport theory is based on the possibility of obtaining exact explicit expressions for the dependence of the second moment and calculation time on the splitting parameters. This allows the automatic optimization of the splitting parameters by ''learning'' the bulk parameters from which the problem dependent coefficients of the quality function (second moment time) are constructed. The above procedure was exploited to implement an automatic optimization of the splitting parameters in the Monte Carlo Neutron Photon (MCNP) code. This was done in a number of steps. In the first instance, only spatial surface splitting was considered. In this step, the major obstacle has been the truncation of an infinite series of ''products'' of ''surface path's'' leading from the source to the detector. Encouraging results from the first phase led to the inclusion of full space/energy phase space splitting. (author)

  5. Studies on blood supply of liver metastasis with DSA, CT and portal vein perfusion CT during superior mesenteric arterial portography

    International Nuclear Information System (INIS)

    Li Zhigang; Shi Gaofeng; Huang Jingxiang; Li Shunzong; Liang Guoqing; Wang Hongguang; Han Pengyin; Wang Qi; Gu Tieshu

    2008-01-01

    Objective: To probe the blood supply of liver metastasis by celiac artery, proper hepatic artery DSA, portal vein perfusion CT during superior mesenteric arterial portography (PCTAP). Methods: One hundred patients with liver metastases were examined prospectively by plain CT scan, multiphase enhanced CT scan, celiac arteriography and proper hepatic arteriography. Of them, 56 patients were examined by PCTAP. All primary lesions were confirmed by operation and (or) pathology examination. In order to investigate the blood supply of metastasis lesions, the software of Photoshop was used to obtain the time-attenuation curves (TDC) of tumor center, tumor edge, portal vein and normal liver parenchyma adjacent to the tumor to calculate liver perfusion for DSA image analysis, while a deconvolution model from CT perfusion software was designed for the dual blood supply. Results: DSA findings: TDC of proper hepatic arteriography showed: the mean peak concentration (K value) in tumor centers was (67 ± 12)%, and it was (76 ± 15)% for peritumor tissue, (51 ± 10)% in normal liver parenchyma. TDC of celiac arteriogaphy showed that the contrast concentration of tumor centers and tumor edge increased fast in early stage, then maintained a slight upward plateau, in the meanwhile, the contrast concentration of normal liver parenchyma kept increasing slowly. PCTAP findings: tumors exhibited no enhancement during 30 s continued scans. Conclusion: The blood supply of liver metastasis mainly comes from hepatic artery, but barely from portal vein. (authors)

  6. The value of MR angiography in the diagnosis of deep vein thrombosis of the lower limbs: comparative study with DSA

    International Nuclear Information System (INIS)

    Feng Min; Wang Shuzhi; Gu Jianping; Sun Jun; Mao Cunnan; Lu Lingquan; Yin Xindao

    2007-01-01

    Objective: To assess the clinical values of MR angiography (MRA) in the detection of deep vein thrombosis of the lower limbs. Methods: Two-dimensional time of flight (2D TOF) MRA was performed in thirty patients who were suspected of having deep vein thrombosis in the lower limbs. The findings of MRA were compared to that of digital subtraction angiography (DSA). Results: twenty-five cases showed deep vein thrombosis in the lower limbs, the MRA findings included venous filling defect (14 cases), occlusions and interruptions of veins (8 cases), venous recanalizations (3 cases), collateral veins (25 cases). Taking the results of DSA as a golden standard, MRA detected all of the affected cases with only one case as the false positive. Conclusion: 2D TOF MRA is a method of choice in the diagnosis of deep vein thrombosis of the lower limbs. (authors)

  7. Intravenous DSA as a screening method for cerebral aneurysms

    International Nuclear Information System (INIS)

    Fukaya, Hiroyuki; Sunami, Kaneo; Hoshi, Seiichiro; Komiya, Hirokazu; Saeki, Naokatsu.

    1990-01-01

    Intravenous DSA (IVDSA) was evaluated as a screening method for cerebral aneurysms. It was performed 390 times in 372 cases. Clinically useful images were obtained in 94.1% in all examinations. Nineteen aneurysms were visualized in cerebral angiography among 21 cases with SAH or 3rd nerve palsy, whereas in IVDSA 15 aneurysms were noted. Aneurysms not visualized in IVDSA were all 4 mm or less in size. Therefore, aneurysms, more than 4 mm in size, which have higher risks for rupture, were detectable in IVDSA. Based on these findings, IVDSA is considered to be clinically useful in screening for aneurysms. In all 372 cases, 33 aneurysms were suspected in IVDSA findings, whereas in cerebral angiography 21 of them turned to be aneurysms. Such 12 false positive cases were distributed mainly at anterior communicating and middle cerebral arteries. Improvement of image resolution, avoidance of vessel overlapping and proper selection of screened cases should be investigated for further development of this screening method. (author)

  8. Nuclear lifetime measurements with the DSA coincidence method in inverse reactions

    International Nuclear Information System (INIS)

    Hermans, J.A.J.

    1977-01-01

    This thesis describes lifetime measurements with the DSA coincidence method in inverse reactions. Bombardment of 2 H and 3 H targets with heavy ions of energies up to 50 MeV produces nuclei recoiling at initial velocities of v(0) approximately equal to 0.05 c. Heavy-ion beams of 11 B, 12 C, 14 N, 16 O, 18 O, 19 F, 27 A1, 28 Si, 30 Si, 31 P, 32 S, 35 Cl and 37 Cl are at present available from the Utrecht 6 MV EN tandem accelerator. The recoil nuclei are slowed down in Mg, Al, Cu, Ag or Au and the γ-ray Doppler pattern is observed with a large Ge(Li) detector in coincidence with protons

  9. Comparison between fast contrast-enhanced MR angiography and DSA in diagnosing spinal cord vascular malformations

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Fang Chun; Wang Jue; Xiao Yunfeng

    2007-01-01

    Objective: To evaluate the diagnostic and clinical value of fast contrast-enhanced MR angiography (CE-MRA) with elliptic centric phase-encoding in spinal cord vascular malformations. Methods Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding and superconducting 1.5T system was applied prospectively in twenty-five consecutive patients with clinically suspected of spinal cord vascular malformations. All cases were performed with selective spinal digital subtraction angiography, including 18 cases treated by surgery and 2 of them with embolization before surgery, MR angiography follow up were undertaken in ten patients after surgery. Comparing fast contrast-enhanced MR angiography with DSA in diagnosing spinal cord vascular malformations included the origin of feeding artery, the feeding artery, the fistula or the nidus, the draining vein, and the vessel image quality based on the gold standard of selective spinal digital subtraction angiography. Results: Surgically proven diseases included spinal arteriovenous malformations(3 cases), spinal cord perimedullary arteriovenous fistulas (5 cases), spinal dural arteriovenous fistulas (8 cases), paravertebral arteriovenous fistulas (1 case), and spontaneous spinal epidural hematomas (2 eases). Comparing with DSA, the accuracy of MR angiography in diagnosing spinal cord vascular malformations; and detecting the origin of the feeding artery, the feeding artery, the shunt or the nidus and the draining vein were 93.8%, 92%, 96.2%, 100% and 100%, respectively. Overall the degree vascular enhencement were judged to be similar(P>0.05), but the vessel continuity of MRA was inferior to DSA (P<0.05). However, 9 cases of MRA showed no abnormal vascular malformation coinciding with those of surgery. Posttreatment MR angiography did not depict any abnormal vessels again. Conclusions: Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding may provide

  10. Gadopentate dimeglumine enhanced MR angiography (MRA) for staging AAA: a correlation with DSA and CT

    International Nuclear Information System (INIS)

    Arlart, I.P.; Gerlach, A.; Kolb, M.; Erpenbach, S.; Wuerstlin, S.

    1997-01-01

    Purpose: To evaluate a contrast-enhanced (CE) MRA sequence for staging AAA. Methods: In 24 patients (male=20, female=4, age=44-81 y) with known AAA the abdominal aorta and its branches including the iliac arteries were imaged, using a 3D GRE-FISP sequence (1.5 T, T R /T E /FA=25/6/35, slab=100-140 mm, 32 part., FOV=440-450 mm, matrix=256x256) during an i.v. infusion of 40 ml of gadopentate dimeglumine. In addition, representative axial single slices (2D breathhold FLASH-sequence: T R /T E /FA=82/5/30) were acquired following contrast application. MR-results were correlated with i.a. DSA and CT studies. Results: With CE-MRA, AAA (n=24) and iliac aneurysms (n=17) could be evaluated in all cases (sens.=100%, spec.=100%) including luminal patency and mural thrombus. 50/54 renal arteries could be identified, 4/6 accessory renal arteries (sens=66,6%, spec.=100%), 8/9 renal artery stenoses>50% (sens.=88.8%, spec.=89.3%), 1/1 renal artery occlusion and 7/8 iliac artery stenoses>50% (sens.=87.5%, spec.=97.5%) were depicted correctly. Proximal portion of sup. mes. art. could be detected and evaluated in 21/24 cases. Quantitative determination of therapeutically relevant vascular paramters using MRA was comparable to DSA and CT. (orig./AJ) [de

  11. Embedded Systems and TensorFlow Frameworks as Assistive Technology Solutions.

    Science.gov (United States)

    Mulfari, Davide; Palla, Alessandro; Fanucci, Luca

    2017-01-01

    In the field of deep learning, this paper presents the design of a wearable computer vision system for visually impaired users. The Assistive Technology solution exploits a powerful single board computer and smart glasses with a camera in order to allow its user to explore the objects within his surrounding environment, while it employs Google TensorFlow machine learning framework in order to real time classify the acquired stills. Therefore the proposed aid can increase the awareness of the explored environment and it interacts with its user by means of audio messages.

  12. New screening system for unruptured cerebral aneurysms; Combination of an expert system and DSA examination

    Energy Technology Data Exchange (ETDEWEB)

    Samejima, Hirotsugu; Ushikubo, Yukio; Mizokami, Toru [Toho Univ., Tokyo (Japan). School of Medicine; and others

    1990-08-01

    We have designed a screening system to diagnose unruptured aneurysms, including the use of digital subtraction angiography (DSA). We surveyed 115 patients who had undergone clipping procedures after subarachnoid hemorrhage (SAH) and questioned them with regard to the subjective symptoms. Sixty-eight of 92 patients who returned the questionnaire reported, prior to rupture, headache,eye pain, and neck pain most frequently, and also impairment of extraocular movements, ptosis, visual field defects, and motor and sensory disturbances. Nineteen (47.5%) of 40 patients who had complete pain relief after surgery complained of headache from 1 week to 1 month before SAH. In addition, nine patients (22.5%) complained of headache for several years, and were also pain-free after surgery. For the indication of DSA, we employed an expert system based on fuzzy set theory. Seven groups of parameters are: Group 1, a basic questionnaire concerning age, sex, and past and family histories; Group 2, 15 warning signs selected on the basis of retrospective study; and Groups 3-7, detailed questions concerning each sign. Scoring weights assigned to each condition based on the results of the retrospective study, and threshold values were determined by several neurosurgeons. The certainty factors for intermediate hypotheses were calculated from these weights and threshold values and summed up, from which the conclusion was obtained. Twelve new cases of unruptured cerebral aneurysm were diagnosed using this screening system. This system may improve the ability to diagnose cerebral aneurysms before rupture. (author).

  13. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C [Toshiba Stroke and Vascular Research Centre, SUNY at Buffalo (United States)

    2016-06-15

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  14. TU-H-CAMPUS-IeP3-02: Neurovascular 4D Parametric Imaging Using Co-Registration of Biplane DSA Sequences with 3D Vascular Geometry Obtained From Cone Beam CT

    International Nuclear Information System (INIS)

    Balasubramoniam, A; Bednarek, D; Rudin, S; Ionita, C

    2016-01-01

    Purpose: To create 4D parametric images using biplane Digital Subtraction Angiography (DSA) sequences co-registered with the 3D vascular geometry obtained from Cone Beam-CT (CBCT). Methods: We investigated a method to derive multiple 4D Parametric Imaging (PI) maps using only one CBCT acquisition. During this procedure a 3D-DSA geometry is stored and used subsequently for all 4D images. Each time a biplane DSA is acquired, we calculate 2D parametric maps of Bolus Arrival Time (BAT), Mean Transit Time (MTT) and Time to Peak (TTP). Arterial segments which are nearly parallel with one of the biplane imaging planes in the 2D parametric maps are co-registered with the 3D geometry. The values in the remaining vascular network are found using spline interpolation since the points chosen for co-registration on the vasculature are discrete and remaining regions need to be interpolated. To evaluate the method we used a patient CT volume data set for 3D printing a neurovascular phantom containing a complete Circle of Willis. We connected the phantom to a flow loop with a peristaltic pump, simulating physiological flow conditions. Contrast media was injected with an automatic injector at 10 ml/sec. Images were acquired with a Toshiba Infinix C-arm and 4D parametric image maps of the vasculature were calculated. Results: 4D BAT, MTT, and TTP parametric image maps of the Circle of Willis were derived. We generated color-coded 3D geometries which avoided artifacts due to vessel overlap or foreshortening in the projection direction. Conclusion: The software was tested successfully and multiple 4D parametric images were obtained from biplane DSA sequences without the need to acquire additional 3D-DSA runs. This can benefit the patient by reducing the contrast media and the radiation dose normally associated with these procedures. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  15. Investigation of microwave assisted drying of samples and evaporation of aqueous solutions in trace element analysis

    Energy Technology Data Exchange (ETDEWEB)

    Maichin, B.; Knapp, G. [Technische Univ., Graz (Austria). Inst. fuer Analytische Chemie, Mikro- und Radiochemie; Kettisch, P. [Anton Paar GmbH, Graz (Austria)

    2000-01-01

    Investigations of microwave assisted drying of sample materials and microwave assisted evaporation of aqueous sample solutions and acidic digestion residues were accomplished by means of special rotors for the microwave digestion system MULTIWAVE. To check the results obtained by microwave assisted drying, the samples were also conventionally dried at 105 C in an oven. The following samples have been dried: 10 g each of meat, fish, apple, cucumber, potato, mustard, yogurt, clay and marl; 1 g each of certified reference material TORT 2 (lobster hepatopancreas), BCR 278 (mussel tissue) and BCR 422 (cod muscle); 500 g garden mould. Microwave assisted drying takes 40 min for organic samples and 30 min for inorganic material. Important is a slow increase of microwave power during the first 20 min. The results agree well with conventional drying at 105 C. Losses of As, Se and Hg have been investigated for 3 CRMs. Only Se shows losses in the range of 20%. Losses of As, Be, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V and Zn after evaporation of aqueous samples and acidic solutions after wet digestion, respectively, have been investigated. 50 mL aqueous solution was evaporated almost to dryness within 25 min. The recovery of Hg is 40-50%, of Se 90-95% and of the other elements 97-102%. 0.2 g each of TORT 2, BCR 278 and BCR 422 have been digested with 4 mL nitric acid and 1 mL hydrochloric acid by means of the microwave digestion system MULTIWAVE. The digestion residue was evaporated almost to dryness and dissolved again in 10 mL diluted nitric acid. In this case no element losses have been observed. The measured concentration of As, Cd, Cu, Fe, Mn, Hg, Pb, Mo, Ni, Se, Sr, V and Zn agree very well with the certified values. An important prerequisite for good recoveries is not to evaporate the solutions to complete dryness. (orig.)

  16. Acute Antibody-Mediated Rejection in Presence of MICA-DSA and Successful Renal Re-Transplant with Negative-MICA Virtual Crossmatch.

    Directory of Open Access Journals (Sweden)

    Yingzi Ming

    Full Text Available The presence of donor-specific alloantibodies (DSAs against the MICA antigen results in high risk for antibody-mediated rejection (AMR of a transplanted kidney, especially in patients receiving a re-transplant. We describe the incidence of acute C4d+ AMR in a patient who had received a first kidney transplant with a zero HLA antigen mismatch. Retrospective analysis of post-transplant T and B cell crossmatches were negative, but a high level of MICA alloantibody was detected in sera collected both before and after transplant. The DSA against the first allograft mismatched MICA*018 was in the recipient. Flow cytometry and cytotoxicity tests with five samples of freshly isolated human umbilical vein endothelial cells demonstrated the alloantibody nature of patient's MICA-DSA. Prior to the second transplant, a MICA virtual crossmatch and T and B cell crossmatches were used to identify a suitable donor. The patient received a second kidney transplant, and allograft was functioning well at one-year follow-up. Our study indicates that MICA virtual crossmatch is important in selection of a kidney donor if the recipient has been sensitized with MICA antigens.

  17. Electro-regeneration of Ce(IV) in real spent Cr-etching solutions

    International Nuclear Information System (INIS)

    Chen, Te-San; Huang, Kuo-Lin

    2013-01-01

    Highlights: • An electrochemical process is used to regenerate Ce(IV) in real (hazardous) spent TFT-LCD Cr-etching solutions. • The Ce(IV) yield on tested anodes was in order BDD > Pt > DSA. • A Neosepta CMX separator was better than Nafion ones to be used in the process. • The activation energy on Pt was 10.7 kJ/mol. • The obtained parameters are useful to design reactors for 100% Ce(IV) regeneration in real spent Cr-etching solutions. -- Abstract: This paper presents the electro-regeneration of Ce(IV) in real (hazardous) spent thin-film transistor liquid-crystal display (TFT-LCD) Cr-etching solutions. In addition to Ce(III) > Ce(IV) in diffusivity, a quasi-reversible behavior of Ce(III)/Ce(IV) was observed at both boron-doped diamond (BDD) and Pt disk electrodes. The Ce(IV) yield on Pt increased with increasing current density, and the best current efficiency (CE) was obtained at 2 A/2.25 cm 2 . The performance in terms of Ce(IV) yield and CE of tested anodes was in order BDD > Pt > dimensional stable anode (DSA). At 2 A/2.25 cm 2 on Pt and 40 °C for 90 min, the Ce(IV) yield, CE and apparent rate constant (k) for Ce(III) oxidation were 81.4%, 21.8% and 3.17 × 10 −4 s −1 , respectively. With the increase of temperature, the Ce(IV) yield, CE, and k increased (activation energy = 10.7 kJ/mol), but the specific electricity consumption decreased. The Neosepta CMX membrane was more suitable than Nafion-117 and Nafion-212 to be used as the separator of the Ce(IV) regeneration process. The obtained parameters are useful to design divided batch reactors for the Ce(IV) electro-regeneration in real spent Cr-etching solutions

  18. Imaging anatomy of dorsal pancreatic artery in patients with diabetes: a comparative study between CTA and DSA

    International Nuclear Information System (INIS)

    Lin Yuning; Li Hui; Yang Xizhang; Chen Ziqian; Tan Jianming; Zhong Qun; Yang Li; Wu Zhixian; Li Huimin; Huang Yisheng

    2011-01-01

    Objective: To investigate the clinical value of 64-section CT angiography (CTA) in detecting the origin of dorsal pancreatic artery (DPA). Methods: Ninety-seven consecutive patients with diabetes received transcatheter infusion of autologous bone marrow-derived stem cell transplantation into DPA. Abdominal CTA was performed in 42 patients before angiography. Celiac trunk, splenic, common hepatic and superior mesenteric arteries were reconstructed in order to locate the origin and traveling course of DPA. A routine angiography of both celiac and superior mesenteric arteries was performed for the demonstration of DPA. Further angiography of splenic and gastroduodenal arteries was carried out if necessary. Taking DSA images as the reference standard, the sensitivity, specificity and accuracy of CTA for DPA detection were calculated. Results: DPA was the main supply artery of pancreas in 85.7% patients (36/42). CTA demonstrated the origin of DPA in 35 cases, although one of which was confirmed to be misjudged (false positive). In seven cases CTA could not demonstrate DPA, and DSA proved that 2 of them was misjudged (false negative). The sensitivity,specificity and accuracy of CTA for DPA detection were 94.4%, 83.3% and 92.9%, respectively. Conclusion: 64-section CTA can accurately detect the origin of main supply artery of pancreas, which is of great value in guiding the interventional procedure for pancreatic diseases. (authors)

  19. Experimental investigations concerning the possible effect of dynamic strain ageing on environmentally-assisted cracking of low alloy steels in oxygenated high-temperature water

    International Nuclear Information System (INIS)

    Roth, A.; Devrient, B.; Haenninen, H.; Bruemmer, G.; Ilg, U.; Widera, M.; Hofmann, H.; Wachter, O.

    2003-01-01

    Service experience has revealed cracks due to environmentally-assisted cracking (EAC) in welds of the feedwater piping system of a boiling water reactor (BWR). Two slightly different low alloy steel (LAS) weld filler metals were used in the system of concern, however, only one of them was affected by cracking. To achieve an improved understanding, a laboratory study was initiated to investigate the crack growth behavior of the two relevant weld filler metals in an oxygenated high-temperature water (HTW) environment representing BWR normal water chemistry (NWC) under sequences of cyclic and constant load. Despite the basic similarities in the nominal chemical composition of both weld filler alloys, the crack growth behaviors revealed significant differences. This could not be explained based on the material's sulphur content, which is known to have a pronounced effect on EAC. To elucidate the observed behavior, studies concerning dynamic strain aging (DSA) have been initiated. DSA has been recently suspected to be another parameter that may influence EAC of LAS in HTW. A reasonable coincidence was observed between the susceptibility to DSA exhibited by slow strain rate tensile tests (SSRT) in air and by internal friction measurements with measured free nitrogen contents on the one hand and with the EAC behavior observed in service and in laboratory experiments on the other hand. (orig.)

  20. Meniscus-assisted solution printing of large-grained perovskite films for high-efficiency solar cells

    Science.gov (United States)

    He, Ming; Li, Bo; Cui, Xun; Jiang, Beibei; He, Yanjie; Chen, Yihuang; O'Neil, Daniel; Szymanski, Paul; Ei-Sayed, Mostafa A.; Huang, Jinsong; Lin, Zhiqun

    2017-07-01

    Control over morphology and crystallinity of metal halide perovskite films is of key importance to enable high-performance optoelectronics. However, this remains particularly challenging for solution-printed devices due to the complex crystallization kinetics of semiconductor materials within dynamic flow of inks. Here we report a simple yet effective meniscus-assisted solution printing (MASP) strategy to yield large-grained dense perovskite film with good crystallization and preferred orientation. Intriguingly, the outward convective flow triggered by fast solvent evaporation at the edge of the meniscus ink imparts the transport of perovskite solutes, thus facilitating the growth of micrometre-scale perovskite grains. The growth kinetics of perovskite crystals is scrutinized by in situ optical microscopy tracking to understand the crystallization mechanism. The perovskite films produced by MASP exhibit excellent optoelectronic properties with efficiencies approaching 20% in planar perovskite solar cells. This robust MASP strategy may in principle be easily extended to craft other solution-printed perovskite-based optoelectronics.

  1. Low-temperature strain ageing in In-Pb alloys under stress relaxation conditions

    International Nuclear Information System (INIS)

    Fomenko, L.S.

    2000-01-01

    The dynamic strain ageing (DSA) of In-Pb (6 and 8 at. % Pb) substitutional solid solution single crystals is studied at temperatures 77-205 K under stress relaxation conditions. The dependences of the stress increment after relaxation connected with DSA on stress relaxation time, stress relaxation rate at the end of the relaxation, temperature, alloy content, flow stress, and strain are determined. It is shown that the DSA kinetic is described by a Harper-type equation with the exponent equal to 1/3 and a low activation energy value (0.3-0.34 eV). This provides a low temperature of the DSA onset (∼ 0.17 T m , where T m is the melt temperature) and is evidence of pipe-mode diffusion. It is supposed that the obstacles to dislocation motion in the crystals studied consist of the groups of solutes, and the strength of the obstacles increases during the DSA due to the pipe diffusion of the solute atoms along the dislocations

  2. Solution-diffusion with defects model for pressure-assisted forward osmosis

    KAUST Repository

    Duan, Jintang

    2014-11-01

    An osmosis transport model is presented that combines the standard internal and external concentration polarization equations in the forward osmosis (FO) field with the selective layer transport equations first proposed by Sherwood in 1967. The Sherwood model describes water flux as the sum of a solute-selective, diffusive component driven by the sum of osmotic pressure and hydraulic pressure differences, and a nonselective, convective component driven by hydraulic pressure difference only. This solution-diffusion with defects (SDWD) model and the solution-diffusion (SD) model were compared against data collected using polyamide thin-film-composite (PA-TFC) and integrally-skinned asymmetric cellulose triacetate (CTA) membranes, evaluated in various configurations. When tested with pure water on the porous support side and 1.5. M (π=72.7. bar) sodium chloride solution on the selective layer side, applying 1.25. bar of hydraulic pressure to the porous support side increased water flux by an order of magnitude for PA-TFC membranes, but had negligible effect on CTA membrane flux. These large flux variations can be explained by the SDWD model, but not the SD model. To confirm the existence of defects, a PA-TFC membrane was coated with a uniform, highly water-permeable, nonselective polymer. After coating to block convection through defects, the influence of hydraulic pressure on water flux through this membrane essentially disappeared. Water flux through these defects is low (<1% of total water flux for PA-TFC membranes) and of little consequence in practical FO or reverse osmosis (RO) applications. But in pressure-assisted forward osmosis (PAFO) or pressure-retarded osmosis (PRO), convective transport through defects affects the solute concentration difference across the membrane selective layer, increasing or decreasing water flux through defect-free regions. The presence of defects may explain why membrane power density in PRO is lower than that predicted based on

  3. Upon a Home Assistant Solution Based on Raspberry Pi Platform

    Directory of Open Access Journals (Sweden)

    Alexandru Florentin IFTIMIE

    2017-01-01

    Full Text Available Our ongoing research on Internet of Things (IoT has been focused on a project aiming to creating a proof of concept for a distributed system capable of controlling common devices found in a house such as TVs, air conditioning units, and other electrical devices. In order to automate these devices, the system integrates various sensors and actuators and, depending of user’s needs and creativity in conceiving and implementing new commands, the system is able to take care and execute the respective commands in a safe and secure manner. This paper presents our current research results upon a personal home assistant solution designed and built around Raspberry Pi V3 platform. The distributed, client-server approach enables users to control home electric and electronic devices from an Android based mobile application.

  4. Mesa redonda: Argentina en proyectos globales de investigaciones espaciales y astronómicas. Uso científico de la Antena de Espacio Profundo DSA 3

    Science.gov (United States)

    Colazo, M.

    2016-08-01

    Argentine has 10 percent of the operative time available for the DSA 3 Antenna of the European Space Agency, installed in Malargüe, Mendoza. Here we present the history of the project and the current activities for the scientific use of the antenna.

  5. Criteria for choice and use of contrast media in intra-arterial D.S.A

    International Nuclear Information System (INIS)

    Dalla-Palma, L.; Stacul, F.; Pozzi-Mucelli, R.

    1985-01-01

    The authors investigated the optimal characteristics of contrast media for use in intra-arterial DSA. 209 injections in 108 patients were evaluated, most of them in the abdominal and peripheral regions. In order to decrease contrast media osmolarity and obtain an adequate mixing with blood, contrast media with low iodine concentration were injected using the same volumes and flow rates of conventional arteriography. Good results were obtained with ionic contrast media, 100 and 150 mgI/ml. depending on the area investigated. The low concentrations allowed the use of ionic agents with an osmolarity very close to that of the non ionic contrast media: the pain has been eliminated and the heat sensation reduced. Furthermore the comparison with the cost of nonionic agents shows a great saving. (orig.)

  6. High performance flexible metal oxide/silver nanowire based transparent conductive films by a scalable lamination-assisted solution method

    Directory of Open Access Journals (Sweden)

    Hua Yu

    2017-03-01

    Full Text Available Flexible MoO3/silver nanowire (AgNW/MoO3/TiO2/Epoxy electrodes with comparable performance to ITO were fabricated by a scalable solution-processed method with lamination assistance for transparent and conductive applications. Silver nanoparticle-based electrodes were also prepared for comparison. Using a simple spin-coating and lamination-assisted planarization method, a full solution-based approach allows preparation of AgNW-based composite electrodes at temperatures as low as 140 °C. The resulting flexible AgNW-based electrodes exhibit higher transmittance of 82% at 550 nm and lower sheet resistance about 12–15 Ω sq−1, in comparison with the values of 68% and 22–25 Ω sq−1 separately for AgNP based electrodes. Scanning electron microscopy (SEM and Atomic force microscopy (AFM reveals that the multi-stacked metal-oxide layers embedded with the AgNWs possess lower surface roughness (<15 nm. The AgNW/MoO3 composite network could enhance the charge transport and collection efficiency by broadening the lateral conduction range due to the built of an efficient charge transport network with long-sized nanowire. In consideration of the manufacturing cost, the lamination-assisted solution-processed method is cost-effective and scalable, which is desire for large-area fabrication. While in view of the materials cost and comparable performance, this AgNW-based transparent and conductive electrodes is potential as an alternative to ITO for various optoelectronic applications.

  7. The operative cooperation and nursing in performing airway stent placement under DSA guidance for treating airway stenosis

    International Nuclear Information System (INIS)

    Yan Baojun; Wu Gang; Han Xinwei; Wang Nan; Shi Jin; Si Wenfeng; Wang Kai; Su Ning; Liu Jia; Hai Dandan

    2011-01-01

    Objective: To discuss the key points of the nursing care for effectively performing airway stent placement under DSA monitoring for airway stenosis. Methods: Corresponding nursing care measures were carried out for 118 patients with airway stenosis who were treated with airway stent placement. Results: The symptom of dyspnea was markedly relieved after stent implantation in all 118 patients with airway stenosis. Conclusion: To strengthen the preoperative psychological nursing and operative posture training, to make close postoperative watch on vital signs, to adopt some prevention measures for possible complications and to give necessary medical advises at the time of discharge are very helpful for patient's recovery after the surgery. (authors)

  8. Driver steering model for closed-loop steering function analysis

    Science.gov (United States)

    Bolia, Pratiksh; Weiskircher, Thomas; Müller, Steffen

    2014-05-01

    In this paper, a two level preview driver steering control model for the use in numerical vehicle dynamics simulation is introduced. The proposed model is composed of cascaded control loops: The outer loop is the path following layer based on potential field framework. The inner loop tries to capture the driver's physical behaviour. The proposed driver model allows easy implementation of different driving situations to simulate a wide range of different driver types, moods and vehicle types. The expediency of the proposed driver model is shown with the help of developed driver steering assist (DSA) function integrated with a conventional series production (Electric Power steering System with rack assist servo unit) system. With the help of the DSA assist function, the driver is prevented from over saturating the front tyre forces and loss of stability and controllability during cornering. The simulation results show different driver reactions caused by the change in the parameters or properties of the proposed driver model if the DSA assist function is activated. Thus, the proposed driver model is useful for the advanced driver steering and vehicle stability assist function evaluation in the early stage of vehicle dynamics handling and stability evaluation.

  9. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E. [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland); Centre for Advanced Medical Imaging (CAMI), St James' s Hospital, Dublin 8 (Ireland); Department of Medical Physics, University of Edinburgh, Edinburgh EH16 4TJ (United Kingdom); Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland)

    2011-02-15

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T{sub 1},T{sub 2}) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast

  10. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    International Nuclear Information System (INIS)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E.

    2011-01-01

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T 1 ,T 2 ) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast to allow

  11. Application of the DSA preconditioned GMRES formalism to the method of characteristics - First results

    International Nuclear Information System (INIS)

    Le Tellier, R.; Hebert, A.

    2004-01-01

    The method of characteristics is well known for its slow convergence; consequently, as it is often done for SN methods, the Generalized Minimal Residual approach (GMRES) has been investigated for its practical implementation and its high reliability. GMRES is one of the most effective Krylov iterative methods to solve large linear systems. Moreover, the system has been 'left preconditioned' with the Algebraic Collapsing Acceleration (ACA) a variant of the Diffusion Synthetic Acceleration (DSA) based on I. Suslov's former works. This paper presents the first numerical results of these methods in 2D geometries with material discontinuities. Indeed, previous investigations have shown a degraded effectiveness of Diffusion Synthetic Accelerations with this kind of geometries. Results are presented for 9 x 9 Cartesian assemblies in terms of the speed of convergence of the inner iterations (fixed source) of the method of characteristics. It shows a significant improvement on the convergence rate. (authors)

  12. Improving tribological performance of gray cast iron by laser peening in dynamic strain aging temperature regime

    Science.gov (United States)

    Feng, Xu; Zhou, Jianzhong; Mei, Yufen; Huang, Shu; Sheng, Jie; Zhu, Weili

    2015-09-01

    A high and stable brake disc friction coefficient is needed for automobile safety, while the coefficient degrades due to elevated temperature during the braking process. There is no better solution except changes in material composition and shape design optimization. In the dynamic strain aging(DSA) temperature regime of gray cast iron, micro-dimples with different dimple depth over diameter and surface area density are fabricated on the material surface by laser peening(LP) which is an LST method. Friction behavior and wear mechanism are investigated to evaluate the effects of surface texturing on the tribological performance of specimens under dry conditions. Through LP impacts assisted by DSA, the friction coefficients of the LPed specimens increase noticeably both at room temperature and elevated temperature in comparison to untreated specimens. Moreover, the coefficient of specimen with dimple depth over diameter of 0.03 and surface area density of 30% is up to 0.351 at room temperature, which dramatically rises up to 1.33 times that of untextured specimen and the value is still up to 0.3305 at 400°C with an increasing ratio of 35% compared to that of untreated specimen. The surface of textured specimen shows better wear resistance compared to untreated specimen. Wear mechanism includes adhesive wear, abrasive wear and oxidation wear. It is demonstrated that LP assisted by DSA can substantially improve wear resistance, raise the friction coefficient as well as its stability of gray cast iron under elevated temperatures. Heat fade and premature wear can be effectively relieved by this surface modification method.

  13. 2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

    International Nuclear Information System (INIS)

    Katoh, Marcus; Opitz, Armin; Minko, Peter; Massmann, Alexander; Berlich, Joachim; Bücker, Arno

    2011-01-01

    Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean ± SD age 67 ± 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70–100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

  14. Synthetic acceleration methods for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.; Larsen, E.W.

    1992-01-01

    The diffusion synthetic acceleration (DSA) algorithm effectively accelerates the iterative solution of transport problems with isotropic or mildly anisotropic scattering. However, DSA loses its effectiveness for transport problems that have strongly anisotropic scattering. Two generalizations of DSA are proposed, which, for highly anisotropic scattering problems, converge at least an order of magnitude (clock time) faster than the DSA method. These two methods are developed, the results of Fourier analysis that theoretically predict their efficiency are described, and numerical results that verify the theoretical predictions are presented. (author). 10 refs., 7 figs., 5 tabs

  15. Synthetic acceleration methods for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.; Larsen, E.W.

    1991-01-01

    This paper reports on the diffusion synthetic acceleration (DSA) algorithm that effectively accelerates the iterative solution of transport problems with isotropic or mildly anisotropic scattering. However, DSA loses its effectiveness for transport problems that have strongly anisotropic scattering. Two generalizations of DSA are proposed, which, for highly anisotropic scattering problems, converge at least an order of magnitude (clock time) faster than the DSA method. These two methods are developed, the results of Fourier analyses that theoretically predict their efficiency are described, and numerical results that verify the theoretical predictions are presented

  16. Characterization of arterial stenosis using 3D imaging: comparison between three imaging techniques (MRA, spiral CTA and 3D DSA) and four display methods (MIP, SR, MPVR, VA) in a phantom study

    International Nuclear Information System (INIS)

    Bendib, K.; Poirier, C.; Croisille, P.; Roux, J.P.; Devel, D.; Amiel, M.

    1999-01-01

    Introduction: accurate assessment of arterial stenosis is a major public health issue for the diagnosis and treatment of cardiovascular diseases. The number of imaging techniques and types of software for display of imaging data is increasing. Few studies that compare these different techniques are available in the literature. Materials and methods: using phantoms to reproduce the main types of arterial stenosis, the authors compared three 3D acquisition techniques (MRA, CTA, and 3D DSA) and four types of display methods (MIP, SR, MPVR, and VA). The degree, the shape, and the location of different types of stenoses were analyzed by three experienced observers during two successive readings. Intra- and inter-observer reproducibility were assessed. The results of the various acquisition techniques and display methods also were compared to the digital reference data (CFAO) of the physical phantoms. Results: the degree of intra- and inter-observer reproducibility for the assessment of shape and location of the stenoses was good. Visual assessment of the degree of stenosis showed significant differences between two observers as well as in two readings by one observer. The 3D DSA was the most accurate technique for assessing the degree of stenosis. CTA provided better results than MRA. MPVR provided an accurate assessment of the degree of the stenosis. 3D DSA and CTA assessed stenosis form and localization adequately, with no significant difference; both methods appeared to be more accurate than MRA. SR provided the best information on the eccentric nature of the stenosis. The shape was very well assessed by VA and MPVR. Conclusions: even though 3D DSA is the most accurate acquisition technique for visualization, the combined use of SR and MPVR appears to be the best compromise to describe the morphology and degree of stenosis. Further improvements in automatic 3D image processing could offer a better understanding and increased possibilities for assessing arterial

  17. An automated computerized methodology for the segmentation of in vivo acquired DSA images: application in the New Zealand hindlimb ischemia model

    International Nuclear Information System (INIS)

    Kagadis, G C; Daskalakis, A; Spyridonos, P; Nikiforidis, G C; Diamantopoulos, A; Samaras, N; Katsanos, K; Karnabatidis, D; Siablis, D; Sourgiadaki, E; Cavouras, D

    2009-01-01

    In-vivo dynamic visualization and accurate quantification of vascular networks is a prerequisite of crucial importance in both therapeutic angiogenesis and tumor anti-angiogenesis studies. A user independent computerized tool was developed, for the automated segmentation and quantitative assessment of in-vivo acquired DSA images. Automatic vessel assessment was performed employing the concept of image structural tensor. Initially, vasculature was estimated according to the largest eigenvalue of the structural tensor. The resulted eigenvalue matrix was treated as gray-matrix from which the vessels were gradually segmented and then categorized in three main sub-groups; large, medium and small-size vessels. The histogram percentiles, corresponding to 85%, 65% and 47% of prime eigenvalue gray-matrix were optimally found to give the thresholds T1, T2 and T3 respectively, for extracting vessels of different size. The proposed methodology was tested on a series of DSA images in both normal rabbits (group A) and in rabbits with experimental induced chronic hindlimb ischemia (group B). As a result an automated computerized tool was developed to process images without any user intervention in either experimental or clinical studies. Specifically, a higher total vascular area and length were calculated in group B compared to group A (p=0.0242 and p=0.0322 respectively), which is in accordance to the fact that significantly more collateral arteries are developed during the physiological response to the stimuli of ischemia.

  18. On the use of diffusion synthetic acceleration in parallel 3D neutral particle transport calculations

    International Nuclear Information System (INIS)

    Brown, P.; Chang, B.

    1998-01-01

    The linear Boltzmann transport equation (BTE) is an integro-differential equation arising in deterministic models of neutral and charged particle transport. In slab (one-dimensional Cartesian) geometry and certain higher-dimensional cases, Diffusion Synthetic Acceleration (DSA) is known to be an effective algorithm for the iterative solution of the discretized BTE. Fourier and asymptotic analyses have been applied to various idealizations (e.g., problems on infinite domains with constant coefficients) to obtain sharp bounds on the convergence rate of DSA in such cases. While DSA has been shown to be a highly effective acceleration (or preconditioning) technique in one-dimensional problems, it has been observed to be less effective in higher dimensions. This is due in part to the expense of solving the related diffusion linear system. We investigate here the effectiveness of a parallel semicoarsening multigrid (SMG) solution approach to DSA preconditioning in several three dimensional problems. In particular, we consider the algorithmic and implementation scalability of a parallel SMG-DSA preconditioner on several types of test problems

  19. Addition of Sodium Bicarbonate to Irrigation Solution May Assist in Dissolution of Uric Acid Fragments During Ureteroscopy.

    Science.gov (United States)

    Paonessa, Jessica E; Williams, James C; Lingeman, James E

    2018-04-01

    We hypothesized that adding sodium bicarbonate (bicarb) to normal saline (NS) irrigation during ureteroscopy in patients with uric acid (UA) nephrolithiasis may assist in dissolving small stone fragments produced during laser lithotripsy. In vitro testing was performed to determine whether dissolution of UA fragments could be accomplished within 1 hour. In total 100% UA renal calculi were fragmented, filtered, and separated by size. Fragment sizes were <0.5 mm and 0.5 to 1 mm. Similar amounts of stone material were agitated in solution at room temperature. Four solutions were tested (NS, NS +1 ampule bicarb/L, NS +2, NS +3). Both groups were filtered to remove solutions after fixed periods. Filtered specimens were dried and weighed. Fragment dissolution rates were calculated as percent removed per hour. Additional testing was performed to determine whether increasing the temperature of solution affected dissolution rates. For fragments <0.5 mm, adding 2 or 3 bicarb ampules/L NS produced a dissolution rate averaging 91% ± 29% per hour. This rate averaged 226% faster than NS alone. With fragments 0.5 to 1 mm, addition of 2 or 3 bicarb ampules/L NS yielded a dissolution rate averaging 22% ± 7% per hour, which was nearly five times higher than NS alone. There was a trend for an increase in mean dissolution rate with higher temperature but this increase was not significant (p = 0.30). The addition of bicarbonate to NS more than doubles the dissolution rate of UA stone fragments and fragments less than 0.5 mm can be completely dissolved within 1 hour. Addition of bicarb to NS irrigation is a simple and inexpensive approach that may assist in the dissolution of UA fragments produced during ureteroscopic laser lithotripsy. Further studies are needed to determine whether a clinical benefit exists.

  20. Electrochemical degradation of reactive dyes at different DSA compositions

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rodrigo G. da; Aquino Neto, Sydney; Andrade, Adalgisa R. de, E-mail: ardandra@ffclrp.usp.b [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Fac. de Filosofia Ciencias e Letras. Dept. de Quimica

    2011-07-01

    This paper investigates the electrochemical oxidation of the reactive dyes reactive blue 4 (RB-4) and reactive orange 16 (RO-16) on RuO{sub 2} dimensionally stable anode (DSA) electrodes. Electrolysis was achieved under galvanostatic control as a function of supporting electrolyte and electrode composition. The electrolyses, performed in either the presence or absence of NaCl, were able to promote efficient color removal; moreover, at low chloride concentration (0.01 mol L{sup -1}), total color removal was obtained after just 10 min of electrolysis, and a significant increase in total dye combustion was achieved for all the studied anodes in chloride medium (reaching ca. 80% - chemical oxygen demand - COD removal). No significant enhancement in dye color removal or mineralization was observed upon increasing chloride concentration. The influence of oxide composition on dye elimination seems to be significant in both media (with or without chloride), being Ti/Ru{sub 0.30}Ti{sub 0.70}O{sub 2}, the most active material for organic compound oxidation. The oxygen evolution reaction was shown to be a limiting reaction in both supporting electrolytes; i.e., NaCl and Na{sub 2}SO{sub 4}, and its competition with organic compound oxidation remained an obstacle. The adsorbable organo halogens formation study revealed that there is slight consumption of the undesirable species formed within the first minutes of the electrolysis, being Ti/(RuO{sub 2}){sub 0.70}(Ta{sub 2}O{sub 5}){sub 0.30} the most environmentally friendly composition. Both anode composition and chloride concentration affect the formation of these undesirable compounds. (author)

  1. Exact measurement of vascular lumina in digital subtraction arteriography (DSA) during stent implantations and percutaneous transluminal angioplasty (PTA)

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, T [Dept. of Radiology, Univ. of Munich (Germany); Kueffer, G [Dept. of Radiology, Univ. of Munich (Germany); Hahn, D [Dept. of Radiology, Univ. of Munich (Germany)

    1992-06-01

    There are inherent difficulties in using high-resolution DSA in interventional radiology for measuring vascular luminal diameter since enlargement ratios are not constant. We present a system that permits accurate determination of vascular lumen diameters by means of a special angiographic catheter with predefined marking points. The accuracy of this measuring method was explored in tests using phantoms. In vivo practicability of the method was proved in PTA and stent implantations in 39 patients. This method with a maximum error of measurement of 5% appears to provide adequate safety in the choice of suitable dilating balloons and stents in interventional vascular procedures. In follow-up, it permits the accurate measurement of neo-intimal thickness. (orig.)

  2. Electrolysis-assisted mitigation of reverse solute flux in a three-chamber forward osmosis system.

    Science.gov (United States)

    Zou, Shiqiang; He, Zhen

    2017-05-15

    Forward osmosis (FO) has been widely studied for desalination or water recovery from wastewater, and one of its key challenges for practical applications is reverse solute flux (RSF). RSF can cause loss of draw solutes, salinity build-up and undesired contamination at the feed side. In this study, in-situ electrolysis was employed to mitigate RSF in a three-chamber FO system ("e-FO") with Na 2 SO 4 as a draw solute and deionized (DI) water as a feed. Operation parameters including applied voltage, membrane orientation and initial draw concentrations were systematically investigated to optimize the e-FO performance and reduce RSF. Applying a voltage of 1.5 V achieved a RSF of 6.78 ± 0.55 mmol m -2  h -1 and a specific RSF of 0.138 ± 0.011 g L -1 in the FO mode and with 1 M Na 2 SO 4 as the draw, rendering ∼57% reduction of solute leakage compared to the control without the applied voltage. The reduced RSF should be attributed to constrained ion migration induced by the coactions of electric dragging force (≥1.5 V) and high solute rejection of the FO membrane. Reducing the intensity of the solution recirculation from 60 to 10 mL min -1 significantly reduced specific energy consumption of the e-FO system from 0.693 ± 0.127 to 0.022 ± 0.004 kWh m -3 extracted water or from 1.103 ± 0.059 to 0.044 ± 0.002 kWh kg -1 reduced reversed solute. These results have demonstrated that the electrolysis-assisted RSF mitigation could be an energy-efficient method for controlling RSF towards sustainable FO applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Effects of traction on the blood circulation of femoral head: DSA study on a canine model

    International Nuclear Information System (INIS)

    Yang Xiujun; Xiao Jian; Ren Qile; Fu Shiping; Li Wei; Xiao Xiangsheng

    2010-01-01

    Objective: To study the influence of traction on the blood circulation of femur head and its evaluation by DSA. Methods: Using micro-catheter, transfemoral selective femoral circumflex arteriography in 22 healthy dogs was performed in unilateral hip before (Group A, n=22) and immediately (Group B, n=22), 30 (Group D, n=22), 60 (Group E, n=20), 90 (Group F, n=10), 120 (Group G, n= 10) minutes during 2 kg skin hip traction, and immediately after traction removal (Group H, I, J, L and O) , and 30 minutes after traction removal with 60, 90 and 120 minutes continuous traction (Group K, M and P) , and 60 minutes after traction removal with 90 and 120 minutes continuous traction (Group N and Q). DSA was also performed immediately during 4 kg weight traction before continuous traction in 12 hips (Group C). Blood circulation of the femoral head was evaluated mainly by observing its perfusion and time of circulation. Femur head perfusion was assessed as good scoring 3, poor scoring 2 and extremely poor scoring 1. Femur head circulation time was assessed as normal scoring 3, prolonged scoring 2 and remarkably prolonged scoring 1. Analysis of variance was employed for analysis of the angiographic findings between different groups. Results: Good femoral head perfusion in Group A to Q was 22, 0, 0, 0, 0, 0, 0, 22, 22, 1, 18, 0, 0, 8, 0, 0 and 1 hips respectively, poor one was 0, 22, 8, 22, 15, 4, 1, 0, 0, 15, 2, 4, 6, 2, 1, 3 and 8 hips, respectively, extremely poor one was 0, 0, 4, 0, 5, 6, 9, 0, 0, 4, 0, 6, 4, 0, 9, 7 and 1 hips, respectively; and normal femoral head blood circulation time was 22, 0, 0, 0, 0, 0, 0, 22, 22, 1, 18, 0, 0, 8, 0, 0 and 1 hips, respectively, prolonged one was 0, 22, 9, 22, 15, 4, 2, 0, 0, 15, 2, 5, 7, 2, 2, 4 and 8 hips, respectively, remarkably prolonged one was 0, 0, 3, 0, 5, 6, 8, 0, 0, 4, 0, 5, 3, 0, 8, 6 and 1 hips, respectively. F value of femoral head perfusion among group A and B,group B and C, group B, D, E, F and G, Group H, I, J, L and O

  4. Evaluation of angiographic delayed vasospasm due to ruptured aneurysm in comparison with cerebral circulation time measured by IA-DSA

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Hatayama, Takashi; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-05-01

    Delayed vasospasm due to ruptured aneurysm has been basically evaluated by angiographic changes in contrast to clinical features such as delayed ischemic neurological deficits (DIND). However, the discrepancies between angiographic and clinical findings have been pointed out. In this study, angiographic changes and cerebral circulation time in ruptured aneurysms were simultaneously investigated with IA-DSA. Thirty-two patients, who had ruptured aneurysms at the anterior circle of Willis and neck clippings at the acute stage, were investigated. Carotid angiogram was performed with IA-DSA on the 7-13th day after the attack. Angiographic changes were evaluated by Fischer's classification and circulation time was calculated in the following way. A time-density curve was obtained at the two ROI's: the C3-C4 portion and the rolandic vein. Circulation time was defined by the difference between the time showing peak optical density at the carotid and the venous portion. The control value of this circulation time obtained from 20 cases with non-rupture aneurysm and epilepsy was 3.4 sec (53 year old) on the average. X-ray CT scan examination was performed at the same time and clinical features were observed every day. Angiographically, 3 cases were free from vasospasm, 18 cases were found to present slight to moderate vasospasm, and 11 cases showed severe vasospasm. Circulation time in patients with no spasm was 3.6 seconds, in patients with slight to moderate vasospasm it was 4.3 seconds and in patients with severe vasospasm it was 6.8 seconds. Ten patients showing cerebral infarction on CT scans demonstrated significantly long circulation time, 7.0 seconds on the average. And all patients having severe vasospasm with circulation time more than 6 seconds presented DIND such as hemiparesis. (author).

  5. [Microwave assisted UV electrodeless discharge lamp photochemical degradation of 4-chlorophenol in aquatic solutions].

    Science.gov (United States)

    Ai, Zhi-hui; Jiang, Jun-qing; Yang, Peng; Zhou, Tao; Lu, Xiao-hua

    2004-07-01

    A microwave assisted UV electrodeless discharge lamp system (MW/UV) was used for photo-degradation of 4CP simulated wastewater. In order to evaluate the degradation efficiency of 4CP, UV spectrophotometry and ion chromatography were used for determination of 4CP and Cl- respectively. The degradation rate in MW/UV system was higher than that in the UV system within 120min, which were 52.40% and 21.56% respectively. The degradation efficiency was improved by increasing pH value of the solution, aerating O2 gas, enhancing light intensity, or adding H2O2 oxidant. The degradation of 4CP under MW/UV accords with the first order kinetics equation.

  6. Degradation of atrazine by microwave-assisted electrodeless discharge mercury lamp in aqueous solution.

    Science.gov (United States)

    Ta, Na; Hong, Jun; Liu, Tingfeng; Sun, Cheng

    2006-11-02

    The present study investigates the degradation of atrazine (2-chloro-4-(ethyl amino)-6-isopropyl amino-s-triazine) in aqueous solution by a developed new method, namely by means of a microwave-assisted electrodeless discharge mercury lamp (MW-EDML). An experimental design was conducted to assess the influence of various parameters: pH value, initial concentration, amount of EDML, initial volume and coexisted solvent. Atrazine was degraded completely by EDML in a relatively short time (i.e. t(1/2)=1.2 min for 10 mg/l). Additionally, the identification of main degradation products during atrazine degradation process was conducted by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). This study proposes the degradation mechanism including four possible pathways for atrazine degradation according to the degradation products.

  7. Preparation of Ba1-xSrxWO4 and Ba1-xCaxWO4 films on tungsten plate by mechanically assisted solution reaction at room temperature

    International Nuclear Information System (INIS)

    Rangappa, Dinesh; Fujiwara, Takeshi; Watanabe, Tomoaki; Yoshimura, Masahiro

    2008-01-01

    Preparation of the alkaline earth tungstate films such as Ba 1-x Sr x WO 4 and Ba 1-x Ca x WO 4 on the tungsten substrate was studied with a simple solution process assisted with the ball rotation at room temperature. The solid solution formation and limitations, the effect of oxidizing agent H 2 O 2 and alkaline earth ions concentration on the dissolution of W substrate and the growth of Ba 1-x Sr x WO 4 and Ba 1-x Ca x WO 4 films were studied in detail. The ball rotation assistance plays a very important role to enhance the dissolution of the W substrate and mass transport of the reactant species such as alkaline earth ions and WO 4 2- ions onto the solid/solution interface region, where precipitation occurs. Therefore, the rate of film formation was accelerated by the ball rotation assistance to the reaction system. Ba-rich Ba 1-x Sr x WO 4 and Ba 1-x Ca x WO 4 films were formed without high energy or high temperature treatment

  8. Clean Slate Environmental Remediation DSA for 10 CFR 830 Compliance

    International Nuclear Information System (INIS)

    James L. Traynor, Stephen L. Nicolosi, Michael L. Space, Louis F. Restrepo

    2006-01-01

    Clean Slate Sites II and III are scheduled for environmental remediation (ER) to remove elevated levels of radionuclides in soil. These sites are contaminated with legacy remains of non-nuclear yield nuclear weapons experiments at the Nevada Test Site, that involved high explosive, fissile, and related materials. The sites may also hold unexploded ordnance (UXO) from military training activities in the area over the intervening years. Regulation 10 CFR 830 (Ref. 1) identifies DOE-STD-1120-98 (Ref. 2) and 29 CFR 1910.120 (Ref. 3) as the safe harbor methodologies for performing these remediation operations. Of these methodologies, DOE-STD-1120-98 has been superseded by DOE-STD-1120-2005 (Ref. 4). The project adopted DOE-STD-1120-2005, which includes an approach for ER projects, in combination with 29 CFR 1910.120, as the basis documents for preparing the documented safety analysis (DSA). To securely implement the safe harbor methodologies, we applied DOE-STD-1027-92 (Ref. 5) and DOE-STD-3009-94 (Ref. 6), as needed, to develop a robust hazard classification and hazards analysis that addresses non-standard hazards such as radionuclides and UXO. The hazard analyses provided the basis for identifying Technical Safety Requirements (TSR) level controls. The DOE-STD-1186-2004 (Ref. 7) methodology showed that some controls warranted elevation to Specific Administrative Control (SAC) status. In addition to the Evaluation Guideline (EG) of DOE-STD-3009-94, we also applied the DOE G 420.1 (Ref. 8) annual, radiological dose, siting criterion to define a controlled area around the operation to protect the maximally exposed offsite individual (MOI)

  9. Intersection assistance: a safe solution for older drivers?

    Science.gov (United States)

    Dotzauer, Mandy; Caljouw, Simone R; de Waard, Dick; Brouwer, Wiebo H

    2013-10-01

    Within the next few decades, the number of older drivers operating a vehicle will increase rapidly (Eurostat, 2011). As age increases so does physical vulnerability, age-related impairments, and the risk of being involved in a fatal crashes. Older drivers experience problems in driving situations that require divided attention and decision making under time pressure as reflected by their overrepresentation in at-fault crashes on intersections. Advanced Driver Assistance Systems (ADAS) especially designed to support older drivers crossing intersections might counteract these difficulties. In a longer-term driving simulator study, the effects of an intersection assistant on driving were evaluated. 18 older drivers (M=71.44 years) returned repeatedly completing a ride either with or without a support system in a driving simulator. In order to test the intersection assistance, eight intersections were depicted for further analyses. Results show that ADAS affects driving. Equipped with ADAS, drivers allocated more attention to the road center rather than the left and right, crossed intersections in shorter time, engaged in higher speeds, and crossed more often with a critical time-to-collision (TTC) value. The implications of results are discussed in terms of behavioral adaptation and safety. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Analysis of fallopian tube recanalization in 37 cases with Foley catheter infusion under pressure through DSA

    International Nuclear Information System (INIS)

    Huang Qiuli; Song Kankan; Wu Anle; Shu Jing

    2000-01-01

    Objective: To investigate the safe, effective, simple and direct method in the re-canalization of fallopian tubal obstruction. Methods: Fallopian tubal obstructive infertility in 37 cases were re-canalized with Foley catheter under pressure infusion through DSA, including primary infertility in 17 cases and secondary infertility in 20 cases. The average infertility term was 4 years. Results: In the 37 cases, 18 cases were treated once, twice in 16 cases, and thrice in 3 cases. The oviduct recanalization rate was 95% (35/37) with one failure and another unsatisfactory. After several times of recanalization in 19 cases, the pelvic cavity adhesion were reduced in 15 cases (79%), no change in 3 cases (16%), and aggravated in one case (5%). Conclusions: This method is simple, cheap, safety, effective and low in X-ray exposure. The authors insist on the pelvic cavity adhesion is still the chief cause of infertility after recanalization and still need other kind of treatment

  11. Removal of uranium and thorium from aqueous solution by ultrafiltration (UF) and PAMAM dendrimer assisted ultrafiltration (DAUF)

    International Nuclear Information System (INIS)

    Ilaiyaraja, P.; Ashish Kumar Singha Deb; Ponraju, D.

    2015-01-01

    Studies on removal of U(VI) and Th(IV) from aqueous solution have been carried out by ultrafiltration (UF) and dendrimer assisted ultrafiltration (DAUF) using regenerated cellulose acetate membrane and PAMAM [poly(amido)amine] dendrimer chelating agent. In UF, the U(VI) and Th(IV) are removed from aqueous solution by adsorption/mass deposition on the membrane at pH > 4. In DAUF, the water soluble PAMAM dendrimer chelating agent effectively concentrates these metal ions in retentate thereby preventing the mass deposition on membrane. At acidic pH (≤3), the binding of metal ions with PAMAM dendrimer is very weak and hence PAMAM can be regenerated and reused. Electronic supplementary material. The online version of this article (doi:10.1007/s10967-014-3462-x) contains supplementary material, which is available to authorized users. (author)

  12. Assistance Focus: Africa

    Energy Technology Data Exchange (ETDEWEB)

    2017-05-18

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost Ask an Expert service, a team of international experts has delivered assistance to countries in all regions of the world, including Africa.

  13. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.

    1991-01-01

    The present proceedings contain all papers and posters presented at the CAR 91 meeting. The topics were as follows: Digital image generation including CT, MR, DSA, US, SPECT, PET and DR (41 papers, 31 posters), application systems (22 papers, 14 posters), image management and communication (27 papers, 8 posters), medical workstations (31 papers, 12 posters). The sessions were dealing with social aspects (5 papers, 2 posters), pediatric radialogy (5 papers), and teleradiology (5 papers, 4 posters). (MG) With 389 figs

  14. Just in Time DSA the Hanford Nuclear Safety Basis Strategy

    Energy Technology Data Exchange (ETDEWEB)

    JACKSON, M.W.

    2002-06-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford, Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safely Basis Requirements (the Rule) in January 2001 requires that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSAs that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long-term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: Compliance with the Rule; A ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and Consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD&D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD&D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex.

  15. Just in Time DSA the Hanford Nuclear Safety Basis Strategy

    International Nuclear Information System (INIS)

    JACKSON, M.W.

    2002-01-01

    The U.S. Department of Energy, Richland Operations Office (RL) is responsible for 30 hazard category 2 and 3 nuclear facilities that are operated by its prime contractors, Fluor Hanford, Incorporated (FHI), Bechtel Hanford, Incorporated (BHI) and Pacific Northwest National Laboratory (PNNL). The publication of Title 10, Code of Federal Regulations, Part 830, Subpart B, Safely Basis Requirements (the Rule) in January 2001 requires that the Documented Safety Analyses (DSA) for these facilities be reviewed against the requirements of the Rule. Those DSAs that do not meet the requirements must either be upgraded to satisfy the Rule, or an exemption must be obtained. RL and its prime contractors have developed a Nuclear Safety Strategy that provides a comprehensive approach for supporting RL's efforts to meet its long-term objectives for hazard category 2 and 3 facilities while also meeting the requirements of the Rule. This approach will result in a reduction of the total number of safety basis documents that must be developed and maintained to support the remaining mission and closure of the Hanford Site and ensure that the documentation that must be developed will support: Compliance with the Rule; A ''Just-In-Time'' approach to development of Rule-compliant safety bases supported by temporary exemptions; and Consolidation of safety basis documents that support multiple facilities with a common mission (e.g. decontamination, decommissioning and demolition [DD and D], waste management, surveillance and maintenance). This strategy provides a clear path to transition the safety bases for the various Hanford facilities from support of operation and stabilization missions through DD and D to accelerate closure. This ''Just-In-Time'' Strategy can also be tailored for other DOE Sites, creating the potential for large cost savings and schedule reductions throughout the DOE complex

  16. Diffusion-synthetic acceleration methods for the discrete-ordinates equations

    International Nuclear Information System (INIS)

    Larsen, E.W.

    1983-01-01

    The diffusion-synthetic acceleration (DSA) method is an iterative procedure for obtaining numerical solutions of discrete-ordinates problems. The DSA method is operationally more complicated than the standard source-iteration (SI) method, but if encoded properly it converges much more rapidly, especially for problems with diffusion-like regions. In this article we describe the basic ideas beind the DSA method and give a (roughly chronological) review of its long development. We conclude with a discussion which covers additional topics, including some remaining open problems and the status of current efforts aimed at solving these problems

  17. Diffusion-synthetic acceleration methods for discrete-ordinates problems

    International Nuclear Information System (INIS)

    Larsen, E.W.

    1984-01-01

    The diffusion-synthetic acceleration (DSA) method is an iterative procedure for obtaining numerical solutions of discrete-ordinates problems. The DSA method is operationally more complicated than the standard source-iteration (SI) method, but if encoded properly it converges much more rapidly, especially for problems with diffusion-like regions. In this article we describe the basic ideas behind the DSA method and give a (roughly chronological) review of its long development. We conclude with a discussion which covers additional topics, including some remaining open problems an the status of current efforts aimed at solving these problems

  18. The generalized PN synthetic acceleration method for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.

    1997-01-01

    The diffusion synthetic acceleration (DSA) method has been known to be an effective tool for accelerating the iterative solution of transport equations with isotropic or mildly anisotropic scattering. However, the DSA method is not effective for transport equations that have strongly anisotropic scattering. A generalization of the modified DSA (MDSA) method is proposed that converges (clock time) faster than the MDSA method. This method is developed, the results of a Fourier analysis that theoretically predicts its efficiency are described, and numerical results that verify the theoretical prediction are presented

  19. Multimodal imaging in the elastase-induced aneurysm model in rabbits: a comparative study using serial DSA, MRA and CTA

    International Nuclear Information System (INIS)

    Doerfler, A.; Becker, W.; Wanke, I.; Goericke, S.; Oezkan, N.; Forsting, M.

    2004-01-01

    Background and Purpose: The elastase-induced aneurysm model in rabbits has proved to be suitable for testing new endovascular occlusion devices. The purpose of this study was to evaluate different imaging modalities for the depiction of anatomy and size of elastase-induced aneurysms and for serial follow-up imaging. Materials and Methods: Elastase-induced aneurysms were created in eight Chinchilla bastard rabbits by endoluminal incubation of porcine elastase. Serial imaging was performed using intravenous DSA (IVDSA), contrast-enhanced MRA (CEMRA), and time-of-flight MRA (TOF) 14 days, 4 weeks and 3 months after aneurysm creation. Intraarterial DSA (IADSA) and CT angiography (CTA) were performed after 3 months. Aneurysm size and geometry (height H, width W, neck width N) were compared. Results: On IVDSA after two weeks mean aneurysm height was 6.2 mm (range 2.8-11.0 mm), mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm) and mean aneurysm neck width was 2.7 mm (range 2.0-4.2 mm). We did not observed any statistically significant change in aneurysm dimensions during follow-up at 4 weeks (CEMRA: H: 5.4, W: 2.4, N: 2.4; TOF: H: 5.7, W: 2.4, N: 2.7) and 3 months (CEMRA: H: 5.8, W: 2.6, N: 2.6; TOF: H: 6.9, W: 2.8, N: 3.0). Aneurysm dimensions could be best seen on IADSA (H: 6.2, W: 3.0, N: 2.7) with good correlation to CTA (r=0.94; H: 6.1, W: 2.8, N: 2.6), CE-MRA (r=0.92), and TOF (r=0.97). TOF was superior to CEMRA in delineating the aneurysm wall. Conclusions: Serial imaging using MRA, CTA or intravenous and intraarterial angiography is feasible in the elastase-induced aneurysm model. Contrast-enhanced MRA, TOF-MRA and CTA showed good correlation to IADSA and are all suitable for non-invasive pretherapeutic measurement of aneurysm size. (orig.) [de

  20. Microwave assisted preparation of magnesium phosphate cement (MPC) for orthopedic applications: A novel solution to the exothermicity problem

    International Nuclear Information System (INIS)

    Zhou, Huan; Agarwal, Anand K.; Goel, Vijay K.; Bhaduri, Sarit B.

    2013-01-01

    There are two interesting features of this paper. First, we report herein a novel microwave assisted technique to prepare phosphate based orthopedic cements, which do not generate any exothermicity during setting. The exothermic reactions during the setting of phosphate cements can cause tissue damage during the administration of injectable compositions and hence a solution to the problem is sought via microwave processing. This solution through microwave exposure is based on a phenomenon that microwave irradiation can remove all water molecules from the alkaline earth phosphate cement paste to temporarily stop the setting reaction while preserving the active precursor phase in the formulation. The setting reaction can be initiated a second time by adding aqueous medium, but without any exothermicity. Second, a special emphasis is placed on using this technique to synthesize magnesium phosphate cements for orthopedic applications with their enhanced mechanical properties and possible uses as drug and protein delivery vehicles. The as-synthesized cements were evaluated for the occurrences of exothermic reactions, setting times, presence of Mg-phosphate phases, compressive strength levels, microstructural features before and after soaking in (simulated body fluid) SBF, and in vitro cytocompatibility responses. The major results show that exposure to microwaves solves the exothermicity problem, while simultaneously improving the mechanical performance of hardened cements and reducing the setting times. As expected, the cements are also found to be cytocompatible. Finally, it is observed that this process can be applied to calcium phosphate cements system (CPCs) as well. Based on the results, this microwave exposure provides a novel technique for the processing of injectable phosphate bone cement compositions. - Highlights: • A microwave assisted system for bone cement manufacturing • A solution to exothermicity problem of acid–base reaction based bone cement

  1. Microwave assisted preparation of magnesium phosphate cement (MPC) for orthopedic applications: A novel solution to the exothermicity problem

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Huan, E-mail: Huan.Zhou@rockets.utoledo.edu [Department of Mechanical, Industrial and Manufacturing Engineering, The University of Toledo, Toledo, OH 43606 (United States); Agarwal, Anand K.; Goel, Vijay K. [Department of Bioengineering, The University of Toledo, Toledo, OH 43606 (United States); Bhaduri, Sarit B. [Department of Mechanical, Industrial and Manufacturing Engineering, The University of Toledo, Toledo, OH 43606 (United States); Division of Dentistry, The University of Toledo, Toledo, OH 43606 (United States)

    2013-10-15

    There are two interesting features of this paper. First, we report herein a novel microwave assisted technique to prepare phosphate based orthopedic cements, which do not generate any exothermicity during setting. The exothermic reactions during the setting of phosphate cements can cause tissue damage during the administration of injectable compositions and hence a solution to the problem is sought via microwave processing. This solution through microwave exposure is based on a phenomenon that microwave irradiation can remove all water molecules from the alkaline earth phosphate cement paste to temporarily stop the setting reaction while preserving the active precursor phase in the formulation. The setting reaction can be initiated a second time by adding aqueous medium, but without any exothermicity. Second, a special emphasis is placed on using this technique to synthesize magnesium phosphate cements for orthopedic applications with their enhanced mechanical properties and possible uses as drug and protein delivery vehicles. The as-synthesized cements were evaluated for the occurrences of exothermic reactions, setting times, presence of Mg-phosphate phases, compressive strength levels, microstructural features before and after soaking in (simulated body fluid) SBF, and in vitro cytocompatibility responses. The major results show that exposure to microwaves solves the exothermicity problem, while simultaneously improving the mechanical performance of hardened cements and reducing the setting times. As expected, the cements are also found to be cytocompatible. Finally, it is observed that this process can be applied to calcium phosphate cements system (CPCs) as well. Based on the results, this microwave exposure provides a novel technique for the processing of injectable phosphate bone cement compositions. - Highlights: • A microwave assisted system for bone cement manufacturing • A solution to exothermicity problem of acid–base reaction based bone cement

  2. Evaluation of automatic vacuum- assisted compaction solutions

    Directory of Open Access Journals (Sweden)

    M. Brzeziński

    2011-01-01

    Full Text Available Currently on the mould-making machines market the companies like: DiSA, KUENKEL WAGNER, HAFLINGER, HEINRICH WAGNER SINTO, HUNTER, SAVELLI AND TECHNICAL play significant role. These companies are the manufacturers of various solutions in machines and instalations applied in foundry engineering. Automatic foundry machines for compaction of green sand have the major role in mechanisation and automation processes of making the mould. The concept of operation of automatic machines is based on the static and dynamic methods of compacting the green sand. The method which gains the importance is the compacting method by using the energy of the air pressure. It's the initial stage or the supporting process of compacting the green sand. However in the automatic mould making machines using this method it's essential to use the additional compaction of the mass in order to receive the final parameters of the form. In the constructional solutions of the machines there is the additional division which concerns the method of putting the sand into the mould box. This division distinquishes the transport of the sand with simultaneous compaction or the putting of the sand without the pre-compaction. As the solutions of the major manufacturers are often the subject for application in various foundries, the authors of the paper would like/have the confidence to present their own evaluation process confirmed by their own researches and independent analysis of the producers' solutions.

  3. The pulmonary artery does not participate in the blood supply of lung cancer: experimental and DSA study

    International Nuclear Information System (INIS)

    Han Mingjun; Feng Gansheng; Yang Jianyong; Su Hongying; Zhao Zhongchun

    2000-01-01

    Objective: To investigate whether or not the pulmonary artery participates in the blood supply of lung cancer and its change of morphology and blood flow in lung cancer. Methods: Two different colors of silicone were injected separately into the bronchial and pulmonary arteries of 33 rat models with squamous cell carcinoma of lung. The origin of blood supply of lung cancer and the morphologic change of pulmonary artery were observed under a stereo-microscope. The DSA of bronchial and pulmonary artery were performed simultaneously in 28 patients with lung cancer. Results: The pulmonary branch of rat and patients were reduced,thinned and occluded in the affected lung. The pulmonary artery did not form tumor vessel,and pulmonary blood flow and perfusion were reduced or absent in the affected area. Conclusion: The pulmonary artery did not participate in the blood supply of lung cancer. It is unreasonable to perform transcatheter chemo-embolization for lung cancer via pulmonary artery

  4. Gravity-Assist Trajectories to the Ice Giants: An Automated Method to Catalog Mass-or Time-Optimal Solutions

    Science.gov (United States)

    Hughes, Kyle M.; Knittel, Jeremy M.; Englander, Jacob A.

    2017-01-01

    This work presents an automated method of calculating mass (or time) optimal gravity-assist trajectories without a priori knowledge of the flyby-body combination. Since gravity assists are particularly crucial for reaching the outer Solar System, we use the Ice Giants, Uranus and Neptune, as example destinations for this work. Catalogs are also provided that list the most attractive trajectories found over launch dates ranging from 2024 to 2038. The tool developed to implement this method, called the Python EMTG Automated Trade Study Application (PEATSA), iteratively runs the Evolutionary Mission Trajectory Generator (EMTG), a NASA Goddard Space Flight Center in-house trajectory optimization tool. EMTG finds gravity-assist trajectories with impulsive maneuvers using a multiple-shooting structure along with stochastic methods (such as monotonic basin hopping) and may be run with or without an initial guess provided. PEATSA runs instances of EMTG in parallel over a grid of launch dates. After each set of runs completes, the best results within a neighborhood of launch dates are used to seed all other cases in that neighborhood---allowing the solutions across the range of launch dates to improve over each iteration. The results here are compared against trajectories found using a grid-search technique, and PEATSA is found to outperform the grid-search results for most launch years considered.

  5. Assistance Focus: Africa

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-29

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost 'Ask an Expert' service, a team of international experts has delivered assistance to countries in all regions of the world. High-impact examples from Africa are featured here.

  6. Angular Multigrid Preconditioner for Krylov-Based Solution Techniques Applied to the Sn Equations with Highly Forward-Peaked Scattering

    Science.gov (United States)

    Turcksin, Bruno; Ragusa, Jean C.; Morel, Jim E.

    2012-01-01

    It is well known that the diffusion synthetic acceleration (DSA) methods for the Sn equations become ineffective in the Fokker-Planck forward-peaked scattering limit. In response to this deficiency, Morel and Manteuffel (1991) developed an angular multigrid method for the 1-D Sn equations. This method is very effective, costing roughly twice as much as DSA per source iteration, and yielding a maximum spectral radius of approximately 0.6 in the Fokker-Planck limit. Pautz, Adams, and Morel (PAM) (1999) later generalized the angular multigrid to 2-D, but it was found that the method was unstable with sufficiently forward-peaked mappings between the angular grids. The method was stabilized via a filtering technique based on diffusion operators, but this filtering also degraded the effectiveness of the overall scheme. The spectral radius was not bounded away from unity in the Fokker-Planck limit, although the method remained more effective than DSA. The purpose of this article is to recast the multidimensional PAM angular multigrid method without the filtering as an Sn preconditioner and use it in conjunction with the Generalized Minimal RESidual (GMRES) Krylov method. The approach ensures stability and our computational results demonstrate that it is also significantly more efficient than an analogous DSA-preconditioned Krylov method.

  7. Strategies for enzyme saving during saccharification of pretreated lignocellulo-starch biomass: effect of enzyme dosage and detoxification chemicals

    Directory of Open Access Journals (Sweden)

    M.G. Mithra

    2017-08-01

    Full Text Available Two strategies leading to enzyme saving during saccharification of pretreated lignocellulo-starch biomass (LCSB was investigated which included reducing enzyme dosage by varying their levels in enzyme cocktails and enhancing the fermentable sugar yield in enzyme-reduced systems using detoxification chemicals. Time course release of reducing sugars (RS during 24–120 h was significantly higher when an enzyme cocktail containing full dose of cellulase (16 FPU/g cellulose along with half dose each of xylanase (1.5 mg protein/g hemicelluloses and Stargen (12.5 μl/g biomass was used to saccharify conventional dilute sulphuric acid (DSA pretreated biomass compared to a parallel system where only one-fourth the dose of the latter two enzymes was used. The reduction in RS content in the 120 h saccharified mash to the extent of 3–4 g/L compared to the system saccharified with full complement of the three enzymes could be overcome considerably by supplementing the system (half dose of two enzymes with detoxification chemical mix incorporating Tween 20, PEG 4000 and sodium borohydride. Microwave (MW-assisted DSA pretreated biomass on saccharification with enzyme cocktail having full dose of cellulase and half dose of Stargen along with detoxification chemicals gave significantly higher RS yield than DSA pretreated system saccharified using three enzymes. The study showed that xylanase could be eliminated during saccharification of MW-assisted DSA pretreated biomass without affecting RS yield when detoxification chemicals were also supplemented. The Saccharification Efficiency and Overall Conversion Efficiency were also high for the MW-assisted DSA pretreated biomass. Since whole slurry saccharifcation of pretreated biomass is essential to conserve fermentable sugars in LCSB saccharification, detoxification of soluble inhibitors is equally important as channelling out of insoluble lignin remaining in the residue. As one of the major factors contributing

  8. Dense CdS thin films on fluorine-doped tin oxide coated glass by high-rate microreactor-assisted solution deposition

    Energy Technology Data Exchange (ETDEWEB)

    Su, Yu-Wei, E-mail: suyuweiwayne@gmail.com [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR 97330 (United States); Microproducts Breakthrough Institute and Oregon Process Innovation Center, Corvallis, Oregon 97330 (United States); Ramprasad, Sudhir [Energy Processes and Materials Division, Pacific Northwest National Laboratory, Corvallis, OR 9730 (United States); Microproducts Breakthrough Institute and Oregon Process Innovation Center, Corvallis, Oregon 97330 (United States); Han, Seung-Yeol; Wang, Wei [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR 97330 (United States); Microproducts Breakthrough Institute and Oregon Process Innovation Center, Corvallis, Oregon 97330 (United States); Ryu, Si-Ok [School of Display and Chemical Engineering, Yeungnam University, 214-1 Dae-dong, Gyeonsan, Gyeongbuk 712-749 (Korea, Republic of); Palo, Daniel R. [Barr Engineering Co., Hibbing, MN 55747 (United States); Paul, Brian K. [School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, OR 97330 (United States); Microproducts Breakthrough Institute and Oregon Process Innovation Center, Corvallis, Oregon 97330 (United States); Chang, Chih-hung [School of Chemical, Biological and Environmental Engineering, Oregon State University, Corvallis, OR 97330 (United States); Microproducts Breakthrough Institute and Oregon Process Innovation Center, Corvallis, Oregon 97330 (United States)

    2013-04-01

    Continuous microreactor-assisted solution deposition is demonstrated for the deposition of CdS thin films on fluorine-doped tin oxide (FTO) coated glass. The continuous flow system consists of a microscale T-junction micromixer with the co-axial water circulation heat exchanger to control the reacting chemical flux and optimize the heterogeneous surface reaction. Dense, high quality nanocrystallite CdS thin films were deposited at an average rate of 25.2 nm/min, which is significantly higher than the reported growth rate from typical batch chemical bath deposition process. Focused-ion-beam was used for transmission electron microscopy specimen preparation to characterize the interfacial microstructure of CdS and FTO layers. The band gap was determined at 2.44 eV by UV–vis absorption spectroscopy. X-ray photon spectroscopy shows the binding energies of Cd 3d{sub 3/2}, Cd 3d{sub 5/2}, S 2P{sub 3/2} and S 2P{sub 1/2} at 411.7 eV, 404.8 eV, 162.1 eV and 163.4 eV, respectively. - Highlights: ► CdS films deposited using continuous microreactor-assisted solution deposition (MASD) ► Dense nanocrystallite CdS films can be reached at a rate of 25.2 [nm/min]. ► MASD can approach higher film growth rate than conventional chemical bath deposition.

  9. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  10. Ultrasonic-assisted solution combustion synthesis of porous Na{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C: formation mechanism and sodium storage performance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Qiuyun; Liu, Qing [Huazhong University of Science and Technology, State Key Laboratory of Materials Processing and Die and Mould Technology (China); Chu, Xiangcheng; Zhang, Yiling [Tsinghua University, State Key Laboratory of New Ceramic and Fine Processing (China); Yan, Youwei; Xue, Lihong, E-mail: xuelh@hust.edu.cn; Zhang, Wuxing, E-mail: zhangwx@hust.edu.cn [Huazhong University of Science and Technology, State Key Laboratory of Materials Processing and Die and Mould Technology (China)

    2017-04-15

    Solution combustion synthesis (SCS) is an effective and rapid method for synthesizing nanocrystalline materials. However, the control over size, morphology, and microstructure are rather limited in SCS. Here, we develop a novel ultrasonic-assisted solution combustion route to synthesize the porous and nano-sized Na{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C composites, and reveal the effects of ultrasound on the structural evolution of NVP/C. Due to the cavitation effects generated from ultrasonic irradiation, the ultrasonic-assisted SCS can produce honeycomb precursor, which can be further transformed into porous Na{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C with reticular and hollow structures after thermal treatment. When used as cathode material for Na-ion batteries, the porous Na{sub 3}V{sub 2}(PO{sub 4}){sub 3}/C delivers an initial discharge capacity of 118 mAh g{sup −1} at 0.1 C and an initial coulombic efficiency of 85%. It can retain 93.8% of the initial capacity after 120 cycles at 0.2 C. The results demonstrate that ultrasonic-assisted SCS can be a new strategy to design crystalline nanomaterials with tunable microstructures.

  11. The generalized PN synthetic acceleration method for linear transport problems with highly anisotropic scattering

    International Nuclear Information System (INIS)

    Khattab, K.M.

    1998-01-01

    The diffusion synthetic acceleration (DSA) method has been known to be an effective tool for accelerating the iterative solution of transport equations with isotopic or mildly anisotropic scattering. However, the DSA method is not effective for transport equations that have strongly anisotropic scattering. A generalization of the modified DSA (MDSA) methods is proposed. This method converges (Clock time) faster than the MDSA method. It is developed, the results of a Fourier analysis that theoretically predicts its efficiency are described, and numerical results that verify the theoretical prediction are presented. (author). 9 refs., 2 tabs., 5 figs

  12. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  13. Quantitative analysis of artifacts in 4D DSA: the relative contributions of beam hardening and scatter to vessel dropout behind highly attenuating structures

    Science.gov (United States)

    Hermus, James; Szczykutowicz, Timothy P.; Strother, Charles M.; Mistretta, Charles

    2014-03-01

    When performing Computed Tomographic (CT) image reconstruction on digital subtraction angiography (DSA) projections, loss of vessel contrast has been observed behind highly attenuating anatomy, such as dental implants and large contrast filled aneurysms. Because this typically occurs only in a limited range of projection angles, the observed contrast time course can potentially be altered. In this work, we have developed a model for acquiring DSA projections that models both the polychromatic nature of the x-ray spectrum and the x-ray scattering interactions to investigate this problem. In our simulation framework, scatter and beam hardening contributions to vessel dropout can be analyzed separately. We constructed digital phantoms with large clearly defined regions containing iodine contrast, bone, soft issue, titanium (dental implants) or combinations of these materials. As the regions containing the materials were large and rectangular, when the phantoms were forward projected, the projections contained uniform regions of interest (ROI) and enabled accurate vessel dropout analysis. Two phantom models were used, one to model the case of a vessel behind a large contrast filled aneurysm and the other to model a vessel behind a dental implant. Cases in which both beam hardening and scatter were turned off, only scatter was turned on, only beam hardening was turned on, and both scatter and beam hardening were turned on, were simulated for both phantom models. The analysis of this data showed that the contrast degradation is primarily due to scatter. When analyzing the aneurysm case, 90.25% of the vessel contrast was lost in the polychromatic scatter image, however only 50.5% of the vessel contrast was lost in the beam hardening only image. When analyzing the teeth case, 44.2% of the vessel contrast was lost in the polychromatic scatter image and only 26.2% of the vessel contrast was lost in the beam hardening only image.

  14. Assistance Focus: Latin America/Caribbean (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2015-01-01

    The Clean Energy Solutions Center Ask an Expert service connects governments seeking policy information and advice with one of more than 30 global policy experts who can provide reliable and unbiased quick-response advice and information. The service is available at no cost to government agency representatives from any country and the technical institutes assisting them. This publication presents summaries of assistance provided to African governments, including the benefits of that assistance.

  15. Intraoperative utilization of dexamethasone/bupivacaine/gentamicin solution in laparoscopic assisted vaginal hysterectomy and pain management.

    Science.gov (United States)

    Fulcher, Paul H; Granese, Marsha; Chun, Yoon; Welch, Christine A; Seybold, Dara J; Randall, Gary; DePond, R Todd

    2014-01-01

    Adequately controlling pain is a key component of postoperative care after a hysterectomy. The purpose of this study was to evaluate the effects of two intraperitoneal (IP) administered solutions during Laparoscopic Assisted Vaginal Hysterectomy (LAVH), on the amount of postoperative self-administered morphine. In this prospective, randomized, double blinded study, twenty women undergoing LAVH randomly distributed to two treatment groups: (1) 100 ml dexamethasone/ bupivacaine/ gentamicin (DMG) solution: 60 cc injected vaginally at cuff and 40 cc placed topically via laparoscopy over intra-peritoneal postoperative surfaces (IP) and 5 ml bupivacaine or 5 ml saline injected at the laparoscopic incision sites, (2) 100 ml saline solution: 60 cc injected vaginally at cuff and 40 cc placed topically via laparoscopy over intra-peritoneal postoperative surfaces (IP) and 5 ml bupivacaine or 5 ml saline injected at the laparoscopic incision sites. The amount of morphine utilized by the patients was documented from their patient controlled anesthesia (PCA) pump. Patient parameters recorded included perceived pain score, height, weight, age, race, reason for surgery, pre-surgery medications, American Society of Anesthesiologist (ASA) classification, length of the surgery and estimated blood loss (EBL). Age, EBL, length of surgery, and ASA classification were not significantly different between the groups. The postoperative amount of morphine utilized was higher at 4 (p=.02) and 16 hours (p = .04) and tended to be higher at 8, 12 hours (p=.06), and 24 hours (p=.09) in the saline IP group. Overall the saline IP group (n=10) used (median; range) 21.5; 8-82 mg of morphine while the DMG IP group (n=10) used 10.5; 1-23 mg. No participants reported a postoperative infection. This study demonstrates that intraoperative utilization of DMG solution during LAVH enables patients clinically to have less perceived pain and subsequently tend to utilize about half the amount of morphine

  16. Clean Energy Solutions Center Services (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-04-01

    The Clean Energy Solutions Center (Solutions Center) helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

  17. Krylov Iterative Methods and the Degraded Effectiveness of Diffusion Synthetic Acceleration for Multidimensional SN Calculations in Problems with Material Discontinuities

    International Nuclear Information System (INIS)

    Warsa, James S.; Wareing, Todd A.; Morel, Jim E.

    2004-01-01

    A loss in the effectiveness of diffusion synthetic acceleration (DSA) schemes has been observed with certain S N discretizations on two-dimensional Cartesian grids in the presence of material discontinuities. We will present more evidence supporting the conjecture that DSA effectiveness will degrade for multidimensional problems with discontinuous total cross sections, regardless of the particular physical configuration or spatial discretization. Fourier analysis and numerical experiments help us identify a set of representative problems for which established DSA schemes are ineffective, focusing on diffusive problems for which DSA is most needed. We consider a lumped, linear discontinuous spatial discretization of the S N transport equation on three-dimensional, unstructured tetrahedral meshes and look at a fully consistent and a 'partially consistent' DSA method for this discretization. The effectiveness of both methods is shown to degrade significantly. A Fourier analysis of the fully consistent DSA scheme in the limit of decreasing cell optical thickness supports the view that the DSA itself is failing when material discontinuities are present in a problem. We show that a Krylov iterative method, preconditioned with DSA, is an effective remedy that can be used to efficiently compute solutions for this class of problems. We show that as a preconditioner to the Krylov method, a partially consistent DSA method is more than adequate. In fact, it is preferable to a fully consistent method because the partially consistent method is based on a continuous finite element discretization of the diffusion equation that can be solved relatively easily. The Krylov method can be implemented in terms of the original S N source iteration coding with only slight modification. Results from numerical experiments show that replacing source iteration with a preconditioned Krylov method can efficiently solve problems that are virtually intractable with accelerated source iteration

  18. Coarse mesh and one-cell block inversion based diffusion synthetic acceleration

    Science.gov (United States)

    Kim, Kang-Seog

    DSA (Diffusion Synthetic Acceleration) has been developed to accelerate the SN transport iteration. We have developed solution techniques for the diffusion equations of FLBLD (Fully Lumped Bilinear Discontinuous), SCB (Simple Comer Balance) and UCB (Upstream Corner Balance) modified 4-step DSA in x-y geometry. Our first multi-level method includes a block Gauss-Seidel iteration for the discontinuous diffusion equation, uses the continuous diffusion equation derived from the asymptotic analysis, and avoids void cell calculation. We implemented this multi-level procedure and performed model problem calculations. The results showed that the FLBLD, SCB and UCB modified 4-step DSA schemes with this multi-level technique are unconditionally stable and rapidly convergent. We suggested a simplified multi-level technique for FLBLD, SCB and UCB modified 4-step DSA. This new procedure does not include iterations on the diffusion calculation or the residual calculation. Fourier analysis results showed that this new procedure was as rapidly convergent as conventional modified 4-step DSA. We developed new DSA procedures coupled with 1-CI (Cell Block Inversion) transport which can be easily parallelized. We showed that 1-CI based DSA schemes preceded by SI (Source Iteration) are efficient and rapidly convergent for LD (Linear Discontinuous) and LLD (Lumped Linear Discontinuous) in slab geometry and for BLD (Bilinear Discontinuous) and FLBLD in x-y geometry. For 1-CI based DSA without SI in slab geometry, the results showed that this procedure is very efficient and effective for all cases. We also showed that 1-CI based DSA in x-y geometry was not effective for thin mesh spacings, but is effective and rapidly convergent for intermediate and thick mesh spacings. We demonstrated that the diffusion equation discretized on a coarse mesh could be employed to accelerate the transport equation. Our results showed that coarse mesh DSA is unconditionally stable and is as rapidly convergent

  19. Sm-doped CeO2 single buffer layer for YBCO coated conductors by polymer assisted chemical solution deposition (PACSD) method

    International Nuclear Information System (INIS)

    Li, G.; Pu, M.H.; Sun, R.P.; Wang, W.T.; Wu, W.; Zhang, X.; Yang, Y.; Cheng, C.H.; Zhao, Y.

    2008-01-01

    An over 150 nm thick Sm 0.2 Ce 0.8 O 1.9-x (SCO) single buffer layer has been deposited on bi-axially textured NiW (2 0 0) alloy substrate. Highly in-plane and out-of-plane oriented, dense, smooth and crack free SCO single layer has been obtained via a polymer-assisted chemical solution deposition (PACSD) approach. YBCO thin film has been deposited equally via a PACSD route on the SCO-buffered NiW, the as grown YBCO yielding a sharp transition at T c0 = 87 K as well as J c (0 T, 77 K) ∼ 1 MA/cm 2 . These results indicates that RE (lanthanides other than Ce) doping may be an effective approach to improve the critical thickness of solution derived CeO 2 film, which renders it a promising candidate as single buffer layer for YBCO coated conductors

  20. RDS - A systematic approach towards system thermal hydraulics input code development for a comprehensive deterministic safety analysis

    International Nuclear Information System (INIS)

    Salim, Mohd Faiz; Roslan, Ridha; Ibrahim, Mohd Rizal Mamat

    2014-01-01

    Deterministic Safety Analysis (DSA) is one of the mandatory requirements conducted for Nuclear Power Plant licensing process, with the aim of ensuring safety compliance with relevant regulatory acceptance criteria. DSA is a technique whereby a set of conservative deterministic rules and requirements are applied for the design and operation of facilities or activities. Computer codes are normally used to assist in performing all required analysis under DSA. To ensure a comprehensive analysis, the conduct of DSA should follow a systematic approach. One of the methodologies proposed is the Standardized and Consolidated Reference Experimental (and Calculated) Database (SCRED) developed by University of Pisa. Based on this methodology, the use of Reference Data Set (RDS) as a pre-requisite reference document for developing input nodalization was proposed. This paper shall describe the application of RDS with the purpose of assessing its effectiveness. Two RDS documents were developed for an Integral Test Facility of LOBI-MOD2 and associated Test A1-83. Data and information from various reports and drawings were referred in preparing the RDS. The results showed that by developing RDS, it has made possible to consolidate all relevant information in one single document. This is beneficial as it enables preservation of information, promotes quality assurance, allows traceability, facilitates continuous improvement, promotes solving of contradictions and finally assisting in developing thermal hydraulic input regardless of whichever code selected. However, some disadvantages were also recognized such as the need for experience in making engineering judgments, language barrier in accessing foreign information and limitation of resources. Some possible improvements are suggested to overcome these challenges

  1. RDS - A systematic approach towards system thermal hydraulics input code development for a comprehensive deterministic safety analysis

    Energy Technology Data Exchange (ETDEWEB)

    Salim, Mohd Faiz, E-mail: mohdfaizs@tnb.com.my [Nuclear Energy Department, Tenaga Nasional Berhad, Level 32, Dua Sentral, 50470 Kuala Lumpur (Malaysia); Roslan, Ridha [Nuclear Installation Division, Atomic Energy Licensing Board, Batu 24, Jalan Dengkil, 43800 Dengkil, Selangor (Malaysia); Ibrahim, Mohd Rizal Mamat [Technical Support Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2014-02-12

    Deterministic Safety Analysis (DSA) is one of the mandatory requirements conducted for Nuclear Power Plant licensing process, with the aim of ensuring safety compliance with relevant regulatory acceptance criteria. DSA is a technique whereby a set of conservative deterministic rules and requirements are applied for the design and operation of facilities or activities. Computer codes are normally used to assist in performing all required analysis under DSA. To ensure a comprehensive analysis, the conduct of DSA should follow a systematic approach. One of the methodologies proposed is the Standardized and Consolidated Reference Experimental (and Calculated) Database (SCRED) developed by University of Pisa. Based on this methodology, the use of Reference Data Set (RDS) as a pre-requisite reference document for developing input nodalization was proposed. This paper shall describe the application of RDS with the purpose of assessing its effectiveness. Two RDS documents were developed for an Integral Test Facility of LOBI-MOD2 and associated Test A1-83. Data and information from various reports and drawings were referred in preparing the RDS. The results showed that by developing RDS, it has made possible to consolidate all relevant information in one single document. This is beneficial as it enables preservation of information, promotes quality assurance, allows traceability, facilitates continuous improvement, promotes solving of contradictions and finally assisting in developing thermal hydraulic input regardless of whichever code selected. However, some disadvantages were also recognized such as the need for experience in making engineering judgments, language barrier in accessing foreign information and limitation of resources. Some possible improvements are suggested to overcome these challenges.

  2. Assistance Focus: Asia/Pacific Region

    Energy Technology Data Exchange (ETDEWEB)

    2017-05-22

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost 'Ask an Expert' service, a team of international experts has delivered assistance to countries in all regions of the world, including nearly 30 countries in the Asia/Pacific region. This document highlights a few examples of the Solutions Center's work in the region.

  3. Dense CO2 as a Solute, Co-Solute or Co-Solvent in Particle Formation Processes: A Review

    Directory of Open Access Journals (Sweden)

    Ana V. M. Nunes

    2011-11-01

    Full Text Available The application of dense gases in particle formation processes has attracted great attention due to documented advantages over conventional technologies. In particular, the use of dense CO2 in the process has been subject of many works and explored in a variety of different techniques. This article presents a review of the current available techniques in use in particle formation processes, focusing exclusively on those employing dense CO2 as a solute, co-solute or co-solvent during the process, such as PGSS (Particles from gas-saturated solutions®, CPF (Concentrated Powder Form®, CPCSP (Continuous Powder Coating Spraying Process, CAN-BD (Carbon dioxide Assisted Nebulization with a Bubble Dryer®, SEA (Supercritical Enhanced Atomization, SAA (Supercritical Fluid-Assisted Atomization, PGSS-Drying and DELOS (Depressurization of an Expanded Liquid Organic Solution. Special emphasis is given to modifications introduced in the different techniques, as well as the limitations that have been overcome.

  4. Assistance Focus: Latin America/Caribbean

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-29

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost 'Ask an Expert' service, a team of international experts has delivered assistance to countries in all regions of the world. High-impact examples from the Latin American/Caribbean region are featured here.

  5. Assistance Focus: Asia/Pacific Region

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-29

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost 'Ask an Expert' service, a team of international experts has delivered assistance to countries in all regions of the world. High-impact examples from the Asia/Pacific region are featured here.

  6. 3D printing of intracranial aneurysm based on intracranial digital subtraction angiography and its clinical application.

    Science.gov (United States)

    Wang, Jian-Li; Yuan, Zi-Gang; Qian, Guo-Liang; Bao, Wu-Qiao; Jin, Guo-Liang

    2018-06-01

    The study aimed to develop simulation models including intracranial aneurysmal and parent vessel geometries, as well as vascular branches, through 3D printing technology. The simulation models focused on the benefits of aneurysmal treatments and clinical education. This prospective study included 13 consecutive patients who suffered from intracranial aneurysms confirmed by digital subtraction angiography (DSA) in the Neurosurgery Department of Shaoxing People's Hospital. The original 3D-DSA image data were extracted through the picture archiving and communication system and imported into Mimics. After reconstructing and transforming to Binary STL format, the simulation models of the hollow vascular tree were printed using 3D devices. The intracranial aneurysm 3D printing simulation model was developed based on DSA to assist neurosurgeons in aneurysmal treatments and residency training. Seven neurosurgical residents and 15 standardization training residents received their simulation model training and gave high assessments for the educational course with the follow-up qualitative questionnaire. 3D printed simulation models based on DSA can perfectly reveal target aneurysms and help neurosurgeons select therapeutic strategies precisely. As an educational tool, the 3D aneurysm vascular simulation model is useful for training residents.

  7. Clean Energy Solutions Center Services (Vietnamese Translation)

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    This is a Vietnamese translation of the Clean Energy Solutions Center fact sheet. The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  8. Clean Energy Solutions Center Services (Arabic Translation)

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    This is an Arabic translation of the Clean Energy Solutions Center fact sheet. The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  9. Clean Energy Solutions Center Services (French Translation)

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    This is a French translation of the Clean Energy Solutions Center fact sheet. The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  10. Transvenous DSA: ECG-controlled cardial effects and venous complications after pre-atrial injection of nonionic contrast media

    International Nuclear Information System (INIS)

    Arlart, I.P.; Sigel, H.

    1986-01-01

    Transvenous DSA is a diagnostic technique for ambulatory examination that is well tolerated by patients, although it is commonly known that bolus injection of contrast medium for examination of the cardiovascular system may affect the cardiovascular hemodynamic process. The prospective study described was intended to reveal in 100 patients the effects on ECG data, as well as clinical symptoms of non-tolerance of contrast medium (nonionic, with high iodine content, Iopamidol 370), applied by central pre-atrial injection. In addition, catheterization-induced complications in the venous system of the arm were studied in 130 patients. Change of heart rate was the most frequent effect observed (increase in 49% of patients pretreated with Buscopan, decrease in 36% of non-pretreated patients). The second next effects were supraventricular and ventricular ES (20%), minor prolongations of PQ and QRS intervals (14%), and ST lowering (3%), without clinical symptons. In one case, an attack of Angina pectoris was observed, another patient developed a cutane allergy. After catheterization of brachial vein, thromboses were observed in 3% of patients, as well as local inflammations in 6%, short attacks of fever in 2.3%. The complications were observed for the most part in cases where re-sterilised catheters had been used. (orig.) [de

  11. An evaluation of microwave-assisted fusion and microwave-assisted acid digestion methods for determining elemental impurities in carbon nanostructures using inductively coupled plasma optical emission spectrometry

    KAUST Repository

    Patole, Shashikant P.; Simõ es, Filipa; Yapici, Tahir; Warsama, Bashir H.; Anjum, Dalaver H.; Da Costa, Pedro M. F. J.

    2015-01-01

    A method for the complete digestion of carbon nanostructures has been demonstrated. Photographs (on the left side) show zirconium crucibles containing SWCNTs with flux of Na2CO3 and K2CO3, before and after microwave fusion; (on the right side) the appearance of the final solutions containing dissolved samples, from microwave-assisted fusion and microwave-assisted acid digestion. These solutions were used for determining the trace elemental impurities by ICP‒OES.

  12. RDS; A systematic approach towards system thermal hydraulics input code development for a comprehensive deterministic safety analysis

    International Nuclear Information System (INIS)

    Mohd Faiz Salim; Ridha Roslan; Mohd Rizal Mamat

    2013-01-01

    Full-text: Deterministic Safety Analysis (DSA) is one of the mandatory requirements conducted for Nuclear Power Plant licensing process, with the aim of ensuring safety compliance with relevant regulatory acceptance criteria. DSA is a technique whereby a set of conservative deterministic rules and requirements are applied for the design and operation of facilities or activities. Computer codes are normally used to assist in performing all required analysis under DSA. To ensure a comprehensive analysis, the conduct of DSA should follow a systematic approach. One of the methodologies proposed is the Standardized and Consolidated Reference Experimental (and Calculated) Database (SCRED) developed by University of Pisa. Based on this methodology, the use of Reference Data Set (RDS) as a pre-requisite reference document for developing input nodalization was proposed. This paper shall describe the application of RDS with the purpose of assessing its effectiveness. Two RDS documents were developed for an Integral Test Facility of LOBIMOD2 and associated Test A1-83. Data and information from various reports and drawings were referred in preparing the RDS. The results showed that by developing RDS, it has made possible to consolidate all relevant information in one single document. This is beneficial as it enables preservation of information, promotes quality assurance, allows traceability, facilitates continuous improvement, promotes solving of contradictions and finally assisting in developing thermal hydraulic input regardless of whichever code selected. However, some disadvantages were also recognized such as the need for experience in making engineering judgments, language barrier in accessing foreign information and limitation of resources. Some possible improvements are suggested to overcome these challenges. (author)

  13. Clean Energy Solutions Center Services

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  14. Clean Energy Solutions Center Services (Vietnamese Translation) (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    This is the Vietnamese language translation of the Clean Energy Solutions Center (Solutions Center) fact sheet. The Solutions Center helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

  15. Clean Energy Solutions Center Services (Arabic Translation) (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-06-01

    This is the Arabic translation of the Clean Energy Solutions Center Services fact sheet. The Clean Energy Solutions Center (Solutions Center) helps governments, advisors and analysts create policies and programs that advance the deployment of clean energy technologies. The Solutions Center partners with international organizations to provide online training, expert assistance, and technical resources on clean energy policy.

  16. Nursing assistance for spring coil occlusion for the treatment of intracranial giant internal carotid artery aneurysms

    International Nuclear Information System (INIS)

    Ma Yugang; Mao Yanjun; Yuan Yili; Hu Yaqin; Liu Jing; Xi Juan

    2010-01-01

    Objective: To discuss the importance of balloon occlusion test before interventional treatment of the intracranial giant internal carotid artery aneurysms and to sum up the nursing experience in assisting the procedure. Methods: Proper perioperative nursing measures were carried out for 12 patients, who suffered from intracranial giant internal carotid artery aneurysm and underwent spring coil occlusion treatment. Nursing measures included mental care, observation of the vital signs, prevention of the complications, etc. Results: Neither death nor exacerbation of the condition occurred in all the 12 patients. The patients were discharged from the hospital with a mean hospitalization of nine days. During a follow-up period ranged from 4 months to one year, seven patients had no disagreeable feeling, one patient complained of discomfort but no abnormality was found on follow-up DSA, and disappearance of the aneurysm was observed in 4 patients. Conclusion: The monitoring of the vital signs, the prevention of the complications and the standard nursing care are the key points for ensuring a successful operation in treating intracranial giant internal carotid artery aneurysms with spring coil occlusion. (authors)

  17. Clean Energy Solutions Center Services (Portuguese Translation)

    Energy Technology Data Exchange (ETDEWEB)

    2016-03-01

    This is a Portuguese translation of the Clean Energy Solutions Center Services fact sheet. The Solutions Center offers no-cost expert policy assistance, webinars and training forums, clean energy policy reports, data, and tools provided in partnership with more than 35 leading international and regional clean energy organizations.

  18. Sm-doped CeO{sub 2} single buffer layer for YBCO coated conductors by polymer assisted chemical solution deposition (PACSD) method

    Energy Technology Data Exchange (ETDEWEB)

    Li, G.; Pu, M.H.; Sun, R.P.; Wang, W.T.; Wu, W.; Zhang, X.; Yang, Y. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); Cheng, C.H. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); School of Materials Science and Engineering, University of New South Wales, Sydney, 2052 NSW (Australia); Zhao, Y. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains (Ministry of Education of China), Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); School of Materials Science and Engineering, University of New South Wales, Sydney, 2052 NSW (Australia)], E-mail: yzhao@home.swjtu.edu.cn

    2008-10-20

    An over 150 nm thick Sm{sub 0.2}Ce{sub 0.8}O{sub 1.9-x} (SCO) single buffer layer has been deposited on bi-axially textured NiW (2 0 0) alloy substrate. Highly in-plane and out-of-plane oriented, dense, smooth and crack free SCO single layer has been obtained via a polymer-assisted chemical solution deposition (PACSD) approach. YBCO thin film has been deposited equally via a PACSD route on the SCO-buffered NiW, the as grown YBCO yielding a sharp transition at T{sub c0} = 87 K as well as J{sub c}(0 T, 77 K) {approx} 1 MA/cm{sup 2}. These results indicates that RE (lanthanides other than Ce) doping may be an effective approach to improve the critical thickness of solution derived CeO{sub 2} film, which renders it a promising candidate as single buffer layer for YBCO coated conductors.

  19. 32 CFR 215.9 - Providing military resources to civil authorities.

    Science.gov (United States)

    2010-07-01

    ... requests for firefighting assistance to DSA. (4) Request from civil law enforcement agencies for training... 32 National Defense 2 2010-07-01 2010-07-01 false Providing military resources to civil... DEFENSE (CONTINUED) MISCELLANEOUS EMPLOYMENT OF MILITARY RESOURCES IN THE EVENT OF CIVIL DISTURBANCES...

  20. Signal processing for cognitive radios

    CERN Document Server

    Jayaweera, Sudharman K

    2014-01-01

    This book covers power electronics, in depth, by presenting the basic principles and application details, and it can be used both as a textbook and reference book.  Introduces the specific type of CR that has gained the most research attention in recent years: the CR for Dynamic Spectrum Access (DSA). Provides signal processing solutions to each task by relating the tasks to materials covered in Part II. Specialized chapters then discuss specific signal processing algorithms required for DSA and DSS cognitive radios  

  1. Discontinuous diffusion synthetic acceleration for Sn transport on 2D arbitrary polygonal meshes

    International Nuclear Information System (INIS)

    Turcksin, Bruno; Ragusa, Jean C.

    2014-01-01

    In this paper, a Diffusion Synthetic Acceleration (DSA) technique applied to the S n radiation transport equation is developed using Piece-Wise Linear Discontinuous (PWLD) finite elements on arbitrary polygonal grids. The discretization of the DSA equations employs an Interior Penalty technique, as is classically done for the stabilization of the diffusion equation using discontinuous finite element approximations. The penalty method yields a system of linear equations that is Symmetric Positive Definite (SPD). Thus, solution techniques such as Preconditioned Conjugate Gradient (PCG) can be effectively employed. Algebraic MultiGrid (AMG) and Symmetric Gauss–Seidel (SGS) are employed as conjugate gradient preconditioners for the DSA system. AMG is shown to be significantly more efficient than SGS. Fourier analyses are carried out and we show that this discontinuous finite element DSA scheme is always stable and effective at reducing the spectral radius for iterative transport solves, even for grids with high-aspect ratio cells. Numerical results are presented for different grid types: quadrilateral, hexagonal, and polygonal grids as well as grids with local mesh adaptivity

  2. Cognitive assisted living ambient system: a survey

    Directory of Open Access Journals (Sweden)

    Ruijiao Li

    2015-11-01

    Full Text Available The demographic change towards an aging population is creating a significant impact and introducing drastic challenges to our society. We therefore need to find ways to assist older people to stay independently and prevent social isolation of these population. Information and Communication Technologies (ICT provide various solutions to help older adults to improve their quality of life, stay healthier, and live independently for a time. Ambient Assisted Living (AAL is a field to investigate innovative technologies to provide assistance as well as healthcare and rehabilitation to impaired seniors. The paper provides a review of research background and technologies of AAL.

  3. Clean Energy Solutions Center and SE4All: Partnering to Support Country Actions

    Energy Technology Data Exchange (ETDEWEB)

    2016-05-01

    Since 2012, the Clean Energy Solutions Center (Solutions Center) and Sustainable Energy for All (SE4All) have partnered to deliver information, knowledge and expert assistance to policymakers and practitioners in countries actively working to achieve SE4All objectives. Through SE4All efforts, national governments are implementing integrated country actions to strategically transform their energy markets. This fact sheet details the Solutions Center and SE4All partnership and available areas of technical assistance.

  4. On the Painleve integrability, periodic wave solutions and soliton solutions of generalized coupled higher-order nonlinear Schroedinger equations

    International Nuclear Information System (INIS)

    Xu Guiqiong; Li Zhibin

    2005-01-01

    It is proven that generalized coupled higher-order nonlinear Schroedinger equations possess the Painleve property for two particular choices of parameters, using the Weiss-Tabor-Carnevale method and Kruskal's simplification. Abundant families of periodic wave solutions are obtained by using the Jacobi elliptic function expansion method with the assistance of symbolic manipulation system, Maple. It is also shown that these solutions exactly degenerate to bright soliton, dark soliton and mixed dark and bright soliton solutions with physical interests

  5. A rich solution spray as a refining method in a small capacity, single effect, solar assisted absorption machine with the pair NH3/H2O: Experimental results

    International Nuclear Information System (INIS)

    Mendes, L.F.; Collares-Pereira, M.; Ziegler, F.

    2007-01-01

    Ammonia vapour refining is a common procedure in ammonia-water absorption machines. A solar assisted single effect absorption machine that uses the pair ammonia-water was developed and tested. Its desorber has a built-in adiabatic refining column constituted by a rich solution spray. The refining method proved its feasibility. The spray provided a more or less constant ammonia vapour enrichment of about 1% which is enough for the working temperature ranges of this type of machine. It was also verified that the refining effect of the spray is almost independent of the refrigerant vapour and solution mass flow rates

  6. Fractional Er:YAG laser assisting topical betamethasone solution in combination with NB-UVB for resistant non-segmental vitiligo.

    Science.gov (United States)

    Yan, Ru; Yuan, Jinping; Chen, Hongqiang; Li, Yuan-Hong; Wu, Yan; Gao, Xing-Hua; Chen, Hong-Duo

    2017-09-01

    Resistant non-segmental vitiligo is difficult to be treated. Ablative erbium-YAG (Er:YAG) laser has been used in the treatment of vitiligo, but the ablation of entire epidermis frustrated the compliance of patients. The purpose of this study is to investigate the effects of fractional Er:YAG laser followed by topical betamethasone and narrow band ultraviolet B (NB-UVB) therapy in the treatment of resistant non-segmental vitiligo. The vitiligo lesions of each enrolled patient were divided into four treatment parts, which were all irradiated with NB-UVB. Three parts were, respectively, treated with low, medium, or high energy of Er:YAG laser, followed by topical betamethasone solution application. A control part was spared with laser treatment and topical betamethasone. The treatment period lasted 6 months. The efficacy was assessed by two blinded dermatologists. Treatment protocol with high energy of 1800 mJ/P of fractional Er:YAG laser followed by topical betamethasone solution and in combination with NB-UVB made 60% patients achieve marked to excellent improvement in white patches. The protocol with medium energy of 1200 mJ/P of laser assisted approximate 36% patients achieve such improvement. The two protocols, respectively, showed better efficacies than NB-UVB only protocol. However, fractional Er:YAG laser at low energy of 600 mJ/P did not provide such contributions to the treatment of vitiligo. The fractional Er:YAG laser in combination with topical betamethasone solution and NB-UVB was suitable for resistant non-segmental vitiligo. The energy of laser was preferred to be set at relatively high level.

  7. Polymer-assisted metal deposition (PAMD): a full-solution strategy for flexible, stretchable, compressible, and wearable metal conductors.

    Science.gov (United States)

    Yu, You; Yan, Casey; Zheng, Zijian

    2014-08-20

    Metal interconnects, contacts, and electrodes are indispensable elements for most applications of flexible, stretchable, and wearable electronics. Current fabrication methods for these metal conductors are mainly based on conventional microfabrication procedures that have been migrated from Si semiconductor industries, which face significant challenges for organic-based compliant substrates. This Research News highlights a recently developed full-solution processing strategy, polymer-assisted metal deposition (PAMD), which is particularly suitable for the roll-to-roll, low-cost fabrication of high-performance compliant metal conductors (Cu, Ni, Ag, and Au) on a wide variety of organic substrates including plastics, elastomers, papers, and textiles. This paper presents i) the principles of PAMD, and how to use it for making ii) flexible, stretchable, and wearable conductive metal electrodes, iii) patterned metal interconnects, and d) 3D stretchable and compressible metal sponges. A critical perspective on this emerging strategy is also provided. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Developing Inclusive Technical Capital beyond the Disabled Students’ Allowance in England

    Directory of Open Access Journals (Sweden)

    Simon Hayhoe

    2015-12-01

    Full Text Available The Disabled Students Allowance (DSA is a government grant for students aged 18 years and over in English Higher Education. Amongst other things, this grant supports the provision of traditional assistive technologies. In April 2014, the UK’s Minister for Universities, Science and Cities proposed cuts to the DSA. Although a later announcement delayed these cuts until the academic year 2016−2017, a number of universities are already preparing alternative means to support disabled students. In this article, it is argued that cuts to the DSA will potentially reduce the cultural and technical capitals of students with disabilities and lessen social inclusion in Higher Education. In particular, less support will potentially lead to a reduction in the development of study skills. As a counter weight, this article proposes a new model of inclusive technical capital. This model originates in Bourdieu’s theory of cultural capital and habitus. The proposed model supports the use of native apps and settings in ubiquitous mainstream mobile technologies. It also espouses the use of m-learning for the passive inclusion of students with disabilities. This article also presents the early results of a project on the use of mobile technologies at the London School of Economics and Canterbury Christ Church University. This project found that students with disabilities and their lecturers already used mobile technologies alongside or instead of customized traditional assistive technologies. The project also found that students preferred not to attend, or found it difficult to attend, separate study skills courses using mobile technologies. However, they were more likely to access m-learning tutorial materials on Learning Management Systems. The study concludes that mobile technologies have the potential to develop a number of study skills that are at risk after cuts to the DSA. However, their use in this regard needs further research and support from

  9. Virtual reality system for diagnosis and therapeutic planning of cerebral aneurysms.

    Science.gov (United States)

    Mo, Da-peng; Bao, Sheng-de; Li, Liang; Yi, Zhi-qiang; Zhang, Jia-yong; Zhang, Yang

    2010-08-01

    The virtual reality (VR) system can provide the neurosurgeon to intuitively interact with and manipulate the three dimensional (3-D) image similarly to manipulate a real object. It was seldom reported that the system was used in diagnosis and treatment of cerebral aneurysms. This study aimed to investigate the application of VR system in diagnosis and therapeutic planning of cerebral aneurysms. A total of 24 cases of cerebral aneurysms were enrolled in this study from 2006 to 2008, which diagnosed by 3-D digital subtraction angiography (3D-DSA) or VR-based computed tomography angiographies (CTA). The VR system and 3D-DSA system were used to observe and measure aneurysms and the adjacent vessels. The data of observation and measurements were compared between VR image and 3D-DSA image. All the patients underwent surgical plan and simulated neurosurgical procedures in the VR system. There were 28 aneurysms detected in VR system and 3D-DSA system. The VR system generated clear and vivid 3-D virtual images which clearly displayed the location and size of the aneurysms and their precise anatomical spatial relations to the parent arteries and skull. The location, size and shape of the aneurysms and their anatomical relationship with the adjacent vessels were similar between 3-D virtual image and 3D-DSA, but the spatial relationship between aneurysms and skull only been displayed by VR system. This VR system also could simulate simple surgical procedures and surgical environments. The VR system can provide a highly effective way to provide precise imaging details as same as 3D-DSA system and assist the diagnosis of cerebral aneurysms with virtual 3-D data based on CTA. It significantly enhances the chosen therapeutic strategy of cerebral aneurysms.

  10. A microwave-assisted solution combustion synthesis to produce europium-doped calcium phosphate nanowhiskers for bioimaging applications.

    Science.gov (United States)

    Wagner, Darcy E; Eisenmann, Kathryn M; Nestor-Kalinoski, Andrea L; Bhaduri, Sarit B

    2013-09-01

    Biocompatible nanoparticles possessing fluorescent properties offer attractive possibilities for multifunctional bioimaging and/or drug and gene delivery applications. Many of the limitations with current imaging systems center on the properties of the optical probes in relation to equipment technical capabilities. Here we introduce a novel high aspect ratio and highly crystalline europium-doped calcium phosphate nanowhisker produced using a simple microwave-assisted solution combustion synthesis method for use as a multifunctional bioimaging probe. X-ray diffraction confirmed the material phase as europium-doped hydroxyapatite. Fluorescence emission and excitation spectra and their corresponding peaks were identified using spectrofluorimetry and validated with fluorescence, confocal and multiphoton microscopy. The nanowhiskers were found to exhibit red and far red wavelength fluorescence under ultraviolet excitation with an optimal peak emission of 696 nm achieved with a 350 nm excitation. Relatively narrow emission bands were observed, which may permit their use in multicolor imaging applications. Confocal and multiphoton microscopy confirmed that the nanoparticles provide sufficient intensity to be utilized in imaging applications. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Documentation and Evaluation of Depot Maintenance Cost Accumulation and Reporting at the Naval Air Rework Facility, Jacksonville, Florida.

    Science.gov (United States)

    1984-06-01

    Barilla , 1984). B. NARF JACKSONVILLE 1. Activities and Services NARF Jacksonville is one of the six industrially funded maintenance facilities which...MC =arine Corps N =Navy DSA z Defense Security Assistance OFA - Other Federal Agencies NFA a Non-Federal Agencies 80 1" 6 LIST OF REFERENCES Barilla

  12. Dynamic Speaking Assessments

    Science.gov (United States)

    Hill, Kent; Sabet, Mehran

    2009-01-01

    This article describes an attempt to adopt dynamic assessment (DA) methods in classroom speaking assessments. The study reported in this article focused on four particular applications of dynamic speaking assessment (DSA). The first, "mediated assistance" (MA), involves interaction between an assistor and a learner to reveal problems in…

  13. Thermoluminescence study of Cu and Ag doped lithium tetraborate samples synthesized by water/solution assisted method

    Energy Technology Data Exchange (ETDEWEB)

    Thiyagarajan, S.; Kumar, S.; Vallejo, M.; Sosa, M. [Universidad de Guanajuato, Departamento de Ingenieria Fisica, 37150 Leon, Guanajuato (Mexico); Velusamy, J., E-mail: thiya93@gmail.com [Centro de Investigaciones en Optica, Apdo. Postal 1-948, Leon, Guanajuato (Mexico)

    2016-10-15

    In this paper lithium tetraborate (Li{sub 2}B{sub 4}O{sub 7}) was produced by water/solution assisted synthesis method. Transition metals, such as Cu and Ag were used to dope Li{sub 2}B{sub 4}O{sub 7} in order to enhance its thermoluminescent properties. The heating temperature parameters for synthesis were 750 degrees Celsius for 2 hours and 150 degrees Celsius for another 2 hours. The samples produced by water assisted method were doped at different doping percentage (0.08, 0.12, 0.5, 0.1 and 1%) of Cu and Ag. Pellets of samples were prepared and there were irradiated with different doses (58, 100, 500 and 945 mGy) by using and X-ray source. The characteristics of undoped and doped Li{sub 2}B-4O{sub 7} were determined by X-ray diffraction (XRD), scanning electron microscopy (Sem), photoluminescence and ultraviolet-visible spectroscopy. The chemical composition and their morphologies of the obtained Li{sub 2}B{sub 4}O{sub 7} and Li{sub 2}B{sub 4}O{sub 7}:Cu, Ag was confirmed by XRD and Sem results. The most intense peak of the XRD pattern of the lithium tetraborate sample was determined by comparing to the reference data and was found to have a tetragonal structure. The thermoluminescent glow curves of the pellets exposed to different doses exhibited a clear response to X-ray irradiation. Especially Li{sub 2}B{sub 4}O{sub 7}:Cu presented a good glow curve in all kind of doses. The experimental results showed that this could have good potential applications in radiation dosimetry. The order of kinetics (b), frequency factor (s) and activation energy (E) or the trapping parameters were calculated using peak shape method. (Author)

  14. A simplified spherical harmonic method for coupled electron-photon transport calculations

    International Nuclear Information System (INIS)

    Josef, J.A.

    1996-12-01

    In this thesis we have developed a simplified spherical harmonic method (SP N method) and associated efficient solution techniques for 2-D multigroup electron-photon transport calculations. The SP N method has never before been applied to charged-particle transport. We have performed a first time Fourier analysis of the source iteration scheme and the P 1 diffusion synthetic acceleration (DSA) scheme applied to the 2-D SP N equations. Our theoretical analyses indicate that the source iteration and P 1 DSA schemes are as effective for the 2-D SP N equations as for the 1-D S N equations. Previous analyses have indicated that the P 1 DSA scheme is unstable (with sufficiently forward-peaked scattering and sufficiently small absorption) for the 2-D S N equations, yet is very effective for the 1-D S N equations. In addition, we have applied an angular multigrid acceleration scheme, and computationally demonstrated that it performs as well for the 2-D SP N equations as for the 1-D S N equations. It has previously been shown for 1-D S N calculations that this scheme is much more effective than the DSA scheme when scattering is highly forward-peaked. We have investigated the applicability of the SP N approximation to two different physical classes of problems: satellite electronics shielding from geomagnetically trapped electrons, and electron beam problems. In the space shielding study, the SP N method produced solutions that are accurate within 10% of the benchmark Monte Carlo solutions, and often orders of magnitude faster than Monte Carlo. We have successfully modeled quasi-void problems and have obtained excellent agreement with Monte Carlo. We have observed that the SP N method appears to be too diffusive an approximation for beam problems. This result, however, is in agreement with theoretical expectations

  15. The Fermi-Pasta-Ulam Model Periodic Solutions

    CERN Document Server

    Arioli, G; Terracini, S

    2003-01-01

    We introduce two novel methods for studying periodic solutions of the FPU beta-model, both numerically and rigorously. One is a variational approach, based on the dual formulation of the problem, and the other involves computer-assisted proofs. These methods are used e.g. to construct a new type of solutions, whose energy is spread among several modes, associated with closely spaced resonances.

  16. Assistance Focus: Latin America and the Caribbean Region

    Energy Technology Data Exchange (ETDEWEB)

    2017-05-17

    The Clean Energy Solutions Center, an initiative of the Clean Energy Ministerial, helps countries throughout the world create policies and programs that advance the deployment of clean energy technologies. Through the Solutions Center's no-cost Ask an Expert service, a team of international experts has delivered assistance to countries in all regions of the world, including Latin America and the Caribbean.

  17. The involvement of splenic artery in the blood supply of hepatomas: its DSA findings and interventional treatment

    International Nuclear Information System (INIS)

    Duan Xuhua; Liang Huiming; Feng Gansheng; Zheng Chuangsheng; Ren Jianzhuang

    2009-01-01

    Objective: To investigate the DSA manifestations of the involvement of splenic artery in supplying blood to hepatomas and to assess the therapeutic value of super-selective interventional embolization. Methods: During the period of March 2005-June 2008, 897 patients with hepatoma underwent angiography and the involvement of splenic artery in the blood supply of hepatoma was confirmed in 7 cases. Splenic arteriography was performed by means of super-selective catheterization with 5 F Yashiro catheter together with 3 F SP catheter. The splenic arteries which supplied blood to hepatomas were embolized with hyper-liquid iodized-oil emulsion mixed with chemotherapy drug, which was followed by the injection of sufficient gelatin sponge or ethanol. The clinical results were analyzed. Results: Splenic arteriography revealed that the splenic artery was the main supplying vessel of the hepatoma in two cases, and was not the main supplying vessel of the hepatoma in five cases. The splenic supplying vessels were completely embolized in all 7 cases. After the procedure, AFP level was decreased over 50%, and in two patients it dropped to normal. CT checkup 4-6 weeks after the surgery revealed that the diameter of tumor decreased to 2.5 - 4.6 cm. Conclusion: The involvement of splenic artery in supplying blood to hepatomas is not common. Super-selective catheterization and sufficient embolization of the splenic supplying vessels are very important for improving the interventional effectiveness. (authors)

  18. Microwave-Assisted Green Synthesis of Silver Nanostructures

    Science.gov (United States)

    This account summarizes a microwave (MW)-assisted synthetic approach for producing silver nanostructures. The rapid and in-core MW heating has received considerable attention as a promising new method for the one-pot synthesis of metallic nanostructures in solutions. Conceptually...

  19. Development of Reference Data Set (RDS) for LOBI-MOD2 Integral Test Facility- IAEA Fellowship Training at Nuclear Research Group of San Piero A Grado (GRNSPG), University of PISA, Italy

    International Nuclear Information System (INIS)

    Mohd Rizal Mamat

    2013-01-01

    Deterministic Safety Analysis (DSA) is one of the mandatory requirements conducted for Nuclear Power Plant licensing process in order to ensure compliance with relevant regulatory acceptance criteria. DSA is a technique whereby a set of conservative deterministic rules and requirements are applied for the design and operation of facilities or activities. Computer codes are normally used to assist in performing all required analysis under DSA. In order to ensure a comprehensive analysis, the conduct of DSA should follow a systematic approach. One of the methodologies proposed is the Standardised and Consolidated Reference Experimental (and Calculated) Database (SCRED) developed by University of Pisa which describes the whole processes or steps involved in the preparation of complete database for system thermal-hydraulic code applications for facilities or plants. Under this methodology, the use of Reference Data Set (RDS) as a pre-requisite reference document for developing input nodalization for system thermal-hydraulics code simulation has been proposed. This paper describes the experience of having undergone 2 months of IAEA Fellowship training at Nuclear Research Group of San Piero A Grado (GRNSPG) in University of PISA, Italy and the application of RDS and its effectiveness. Two RDS documents have been developed for an Integral Test Facility of LOBI-MOD2 facility and Test A1-83, 10% small cold leg break LOCA (Loss of Coolant Accident). (author)

  20. Comparison of acidic polymers for the removal of cobalt from water solutions by polymer assisted ultrafiltration

    Energy Technology Data Exchange (ETDEWEB)

    Dambies, Laurent, E-mail: chemjobs@netcourrir.com [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland); Jaworska, Agnieszka, E-mail: a.jaworska@ichtj.waw.pl [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland); Zakrzewska-Trznadel, Grazyna; Sartowska, Bozena [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland)

    2010-06-15

    In this study, three sulfonated water-soluble polymers based on poly(vinyl alcohol) of different molecular weights (10,000, 50,000 and 100,000 Da) were prepared and tested against commercially available poly(acrylic acid) for the removal of cobalt using polymer assisted ultrafiltration. High rejection rates were obtained between pH 3 and 6 with sulfonated poly(vinyl alcohol) (PVA 10,000 and 50,000 Da) whereas poly(acrylic acid) (PAA) of similar molecular weights performed rather poorly in this pH range. Sulfonation improved significantly sorption capability of PVA. Sulfonated PVA 10,000 was the best complexing agent with rejection rate above 95% between pH 3 and 6. For unmodified PVA the rejection rate was only 30-45% at pH 6 and there was no rejection at pH 3 at all. PAA rejection rate was above 90% at pH 6 and only about 10% at pH 3. Large scale experiment in cross-flow, continuous apparatus conducted by using PVA-SO{sub 3}H 10,000 Da to remove {sup 60}Co radioisotope from water solutions showed excellent results demonstrating the potential of this polymer to purify acidic radioactive wastes containing cobalt radioisotopes.

  1. Spin-Assisted Layer-by-Layer Assembly: Variation of Stratification as Studied with Neutron Reflectivity

    International Nuclear Information System (INIS)

    Kharlampieva, Eugenia; Kozlovskaya, Veronika; Chan, Jennifer; Ankner, John Francis; Tsukruk, Vladimir V.

    2009-01-01

    We apply neutron reflectivity to probe the internal structure of spin-assisted layer-by-layer (LbL) films composed of electrostatically assembled polyelectrolytes. We find that the level of stratification and the degree of layer intermixing can be controlled by varying the type and concentration of salt during LbL assembly. We observe well-defined layer structure in spin-assisted LbL films when deposited from salt-free solutions. These films feature 2-nm-thick bilayers, which are ∼3-fold thicker than those in dipped LbL films assembled under similar conditions. Addition of a 10mM phosphate buffer promotes progressive layer inter-diffusion with increasing distance from the substrate. However, adding 0.1M NaCl to the phosphate buffer solution restores the layer stratification. We also find that spin-assisted LbL films obtained from buffer solutions are more highly stratified as compared to the highly intermixed layers seen in dipped LbL films assembled from buffer. Our results yield new insight into the mechanism of spin-assisted LbL assembly that should prove useful for biotechnological applications.

  2. Human-robot interaction strategies for walker-assisted locomotion

    CERN Document Server

    Cifuentes, Carlos A

    2016-01-01

    This book presents the development of a new multimodal human-robot interface for testing and validating control strategies applied to robotic walkers for assisting human mobility and gait rehabilitation. The aim is to achieve a closer interaction between the robotic device and the individual, empowering the rehabilitation potential of such devices in clinical applications. A new multimodal human-robot interface for testing and validating control strategies applied to robotic walkers for assisting human mobility and gait rehabilitation is presented. Trends and opportunities for future advances in the field of assistive locomotion via the development of hybrid solutions based on the combination of smart walkers and biomechatronic exoskeletons are also discussed. .

  3. Stratégies de commandes assistives pour les exosquelettes des membres inférieurs

    OpenAIRE

    HUO , Weiguang

    2016-01-01

    Neurological problems caused by stroke and spinal cord injury as well as the weakness of skeletal muscles may considerably affect the motor ability of the elderly and infirm. Traditional solutions of assistance and treatment for these dependent people are relatively costly; they generally need significant human efforts and financial resources from caregivers and national healthcare centers. In this context, robotics appears as a convenient and promising solution to develop assistive systems f...

  4. Control of PbI2 nucleation and crystallization: towards efficient perovskite solar cells based on vapor-assisted solution process

    Science.gov (United States)

    Yang, Chongqiu; Peng, Yanke; Simon, Terrence; Cui, Tianhong

    2018-04-01

    Perovskite solar cells (PSC) have outstanding potential to be low-cost, high-efficiency photovoltaic devices. The PSC can be fabricated by numerous techniques; however, the power conversion efficiency (PCE) for the two-step-processed PSC falls behind that of the one-step method. In this work, we investigate the effects of relative humidity (RH) and dry air flow on the lead iodide (PbI2) solution deposition process. We conclude that the quality of the PbI2 film is critical to the development of the perovskite film and the performance of the PSC device. Low RH and dry air flow used during the PbI2 spin coating procedure can increase supersaturation concentration to form denser PbI2 nuclei and a more suitable PbI2 film. Moreover, airflow-assisted PbI2 drying and thermal annealing steps can smooth transformation from the nucleation stage to the crystallization stage.

  5. Big Data, Smart Homes and Ambient Assisted Living

    OpenAIRE

    Vimarlund, V.; Wass, S.

    2014-01-01

    Objectives: To discuss how current research in the area of smart homes and ambient assisted living will be influenced by the use of big data. Methods: A scoping review of literature published in scientific journals and conference proceedings was performed, focusing on smart homes, ambient assisted living and big data over the years 2011-2014. Results: The health and social care market has lagged behind other markets when it comes to the introduction of innovative IT solutions and the market f...

  6. An extended view on benefits and barriers of ambient assisted living solutions

    NARCIS (Netherlands)

    Jaschinski, Christina; Allouch, S.B.

    2015-01-01

    Motivated by the older adults’ desire to age in their trusted home environment and the increasing financial pressure on the healthcare system, Ambient Assisted Living (AAL) technologies are designed to facilitate healthy and autonomous aging in place. To aid the acceptance of these still immature

  7. 5th Italian Forum on Ambient Assisted Living

    CERN Document Server

    Siciliano, Pietro; Marletta, Vincenzo; Monteriù, Andrea

    2015-01-01

    This book documents the state of the art in the field of ambient assisted living (AAL), highlighting the impressive potential of novel methodologies and technologies to enhance well-being and promote active ageing. The coverage is wide ranging, with sections on assistive devices, elderly people monitoring, home rehabilitation, ICT solutions for AAL, living with chronic conditions, robotic assistance for the elderly, sensing technologies for AAL, and smart housing. The book comprises a selection of the best papers presented at the Fifth Italian Forum on Ambient Assisted Living, which was held in Catania, Italy, in September 2014 and brought together end users, technology teams, and policy makers to develop a consensus on how to improve provision for elderly and impaired people. Readers will find that the expert contributions offer clear insights into the ways in which the most recent exciting advances may be expected to assist in addressing the needs of the elderly and those with chronic conditions.

  8. 7th Italian Forum on Ambient Assisted Living

    CERN Document Server

    Marletta, Vincenzo; Monteriù, Andrea; Siciliano, Pietro

    2017-01-01

    This book documents the state of the art in the field of ambient assisted living (AAL), highlighting the impressive potential of novel methodologies and technologies to enhance well-being and promote active ageing. The coverage is wide ranging, with sections on assistive devices, elderly people monitoring, home rehabilitation, ICT solutions for AAL, living with chronic conditions, robotic assistance for the elderly, sensing technologies for AAL, and smart housing. The book comprises a selection of the best papers presented at the 7th Italian Forum on Ambient Assisted Living (ForitAAL 2016), which was held in Pisa, Italy, in June 2016 and brought together end users, technology teams, and policy makers to develop a consensus on how to improve provision for elderly and impaired people. Readers will find that the expert contributions offer clear insights into the ways in which the most recent exciti ng advances may be expected to assist in addressing the needs of the elderly and those with chronic conditions.

  9. Salt-assisted and salt-suppressed sol-gel transitions of methylcellulose in water.

    Science.gov (United States)

    Xu, Y; Wang, C; Tam, K C; Li, L

    2004-02-03

    The effects of various salts on the sol-gel transition of aqueous methylcellulose (MC) solutions have been studied systematically by means of a micro differential scanning calorimeter. It was found that the heating process was endothermic while the cooling process was exothermic for both MC solutions with and without salts. The addition of salts did not change the patterns of gelation and degelation of MC. However, the salts could shift the sol-gel transition and the gel-sol transition to lower or higher temperatures from a pure MC solution, depending on the salt type. These opposite effects were termed the salt-assisted and salt-suppressed sol-gel transitions. Either the salt-assisted transition or the salt-suppressed sol-gel transition was a function of salt concentration. In addition, each salt was found to have its own concentration limit for producing a stable aqueous solution of MC at a given concentration of MC, which was related to the anionic charge density of the salt. Cations were proved to have weaker effects than anions. The "salt-out strength", defined as the salt effect per mole of anion, was obtained for each anion studied. The thermodynamic mechanisms involved in the salt-assisted and salt-suppressed sol-gel transitions are discussed.

  10. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  11. La Lavagna Interattiva Multimediale a supporto degli studenti disabili e con DSA all’Università di Modena e Reggio Emilia

    Directory of Open Access Journals (Sweden)

    Giacomo Guaraldi

    2013-03-01

    Full Text Available Negli ultimi anni l’introduzione delle moderne tecnologie ha consentito agli studenti con disabilità di raggiungere un maggior grado di autonomia e ha favorito un mutamento nella didattica che è diventata sempre più una «didattica inclusiva», incentrata sui bisogni educativi speciali di tali soggetti e soprattutto sulle potenzialità nascoste in essi. I software per l’apprendimento, le sintesi vocali, le lavagne interattive multimediali (LIM, i netbook, i tablets, gli Ipad creano una «rete integrata» che permette, grazie a linguaggi diversi e multimodali, di accrescere l’autostima dei soggetti con disabilità e favorire la loro autonomia. La lavagna è uno strumento che stimola l’apprendimento, in quanto utilizza un linguaggio più vicino alla modalità comunicativa delle nuove generazioni, riducendo così la distanza docente e discente. Questo è tanto più importante nel caso di studenti con disabilità o con disturbo specifico dell’apprendimento: il disabile sensoriale può utilizzare la modalità comunicativa residua, il disabile motorio può «sfogliare» un testo, farselo leggere, prendere appunti, il ragazzo con DSA può usufruire della sintesi vocale per la lettura e/o per il supporto alla scrittura.

  12. Key Update Assistant for Resource-Constrained Networks

    DEFF Research Database (Denmark)

    Yuksel, Ender; Nielson, Hanne Riis; Nielson, Flemming

    2012-01-01

    developed a push-button solution - powered by stochastic model checking - that network designers can easily benefit from, and it paves the way for consumers to set up key update related security parameters. Key Update Assistant, as we named it, runs necessary model checking operations and determines...

  13. Dynamic strain aging of twinning-induced plasticity (TWIP) steel in tensile testing and deep drawing

    International Nuclear Information System (INIS)

    Kim, J.G.; Hong, S.; Anjabin, N.; Park, B.H.; Kim, S.K.; Chin, K.-G.; Lee, S.; Kim, H.S.

    2015-01-01

    The dynamic strain aging (DSA) of metallic materials due to solute atom diffusion to mobile dislocations induce deformation instability with load fluctuations and deformation localizations, hence reducing their sheet formability. In this paper, DSA behaviors of twinning induced plasticity (TWIP) steel with and without Al during tensile testing and deep drawing are investigated in terms of strain localization and the Portevin-Le Chatelier (PLC) band. A theoretical DSA model with internal variables of dislocation density and twin volume fraction is presented for an estimation of strain localization and strain hardening behavior of TWIP steels. The simulation results of the load history and PLC bands during tensile testing and deep drawing are in good agreement with the experimental values. A serration behavior is observed in high-Mn TWIP steels and its tensile residual stress is higher than that in the Al-added TWIP steels, which results in a deformation crack or delayed fracture of deep drawn specimens

  14. Image-Based Airborne Sensors: A Combined Approach for Spectral Signatures Classification through Deterministic Simulated Annealing

    Science.gov (United States)

    Guijarro, María; Pajares, Gonzalo; Herrera, P. Javier

    2009-01-01

    The increasing technology of high-resolution image airborne sensors, including those on board Unmanned Aerial Vehicles, demands automatic solutions for processing, either on-line or off-line, the huge amountds of image data sensed during the flights. The classification of natural spectral signatures in images is one potential application. The actual tendency in classification is oriented towards the combination of simple classifiers. In this paper we propose a combined strategy based on the Deterministic Simulated Annealing (DSA) framework. The simple classifiers used are the well tested supervised parametric Bayesian estimator and the Fuzzy Clustering. The DSA is an optimization approach, which minimizes an energy function. The main contribution of DSA is its ability to avoid local minima during the optimization process thanks to the annealing scheme. It outperforms simple classifiers used for the combination and some combined strategies, including a scheme based on the fuzzy cognitive maps and an optimization approach based on the Hopfield neural network paradigm. PMID:22399989

  15. Navigating "Assisted Dying".

    Science.gov (United States)

    Schipper, Harvey

    2016-02-01

    Carter is a bellwether decision, an adjudication on a narrow point of law whose implications are vast across society, and whose impact may not be realized for years. Coupled with Quebec's Act Respecting End-of-life Care it has sharply changed the legal landscape with respect to actively ending a person's life. "Medically assisted dying" will be permitted under circumstances, and through processes, which have yet to be operationally defined. This decision carries with it moral assumptions, which mean that it will be difficult to reach a unifying consensus. For some, the decision and Act reflect a modern acknowledgement of individual autonomy. For others, allowing such acts is morally unspeakable. Having opened the Pandora's Box, the question becomes one of navigating a tolerable societal path. I believe it is possible to achieve a workable solution based on the core principle that "medically assisted dying" should be a very rarely employed last option, subject to transparent ongoing review, specifically as to why it was deemed necessary. My analysis is based on 1. The societal conditions in which have fostered demand for "assisted dying", 2. Actions in other jurisdictions, 3. Carter and Quebec Bill 52, 4. Political considerations, 5. Current medical practice. Leading to a series of recommendations regarding. 1. Legislation and regulation, 2. The role of professional regulatory agencies, 3. Medical professions education and practice, 4. Public education, 5. Health care delivery and palliative care. Given the burden of public opinion, and the legal steps already taken, a process for assisted-dying is required. However, those legal and regulatory steps should only be considered a necessary and defensive first step in a two stage process. The larger goal, the second step, is to drive the improvement of care, and thus minimize assisted-dying.

  16. Follow-up after embolization of ruptured intracranial aneurysms: a prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-11-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization.

  17. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Collegium Medicum, Department of Radiology and Diagnostic Imaging, Bydgoszcz (Poland); Beuth, Wojciech [Nicolaus Copernicus University, Collegium Medicum, Department of Neurosurgery and Neurotraumatology, Bydgoszcz (Poland)

    2012-11-15

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques ({kappa} = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA ({kappa} = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  18. Training the physician assistant in the Netherlands

    NARCIS (Netherlands)

    Spenkelink-Schut, G.; ten Cate, O.Th.J.; Kort, H.S.M.

    2008-01-01

    The concept of the physician assistant (PA) in the United States has served as a model for other countries in providing one solution for the challenges in their health care systems. In the Netherlands there is a growing shortage of adequately trained health care workers, an increasing demand for

  19. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  20. Facile and efficient one-pot solvothermal and microwave-assisted synthesis of stable colloidal solutions of MFe2O4 spinel magnetic nanoparticles

    International Nuclear Information System (INIS)

    Solano, Eduardo; Perez-Mirabet, Leonardo; Martinez-Julian, Fernando; Guzmán, Roger; Arbiol, Jordi; Puig, Teresa; Obradors, Xavier; Yañez, Ramón; Pomar, Alberto; Ricart, Susagna; Ros, Josep

    2012-01-01

    Well-defined synthesis conditions of high quality MFe 2 O 4 (M = Mn, Fe, Co, Ni, Zn, and Cu) spinel ferrite magnetic nanoparticles, with diameters below 10 nm, have been described based on facile and efficient one-pot solvothermal or microwave-assisted heating procedures. Both methods are reproducible and scalable and allow forming concentrated stable colloidal solutions in polar solvents, but microwave-assisted heating allows reducing 15 times the required annealing time and leads to an enhanced monodispersity of the nanoparticles. Non-agglomerated nanoparticles dispersions have been achieved using a simple one-pot approach where a single compound, triethyleneglycol, behaves at the same time as solvent and capping ligand. A narrow nanoparticle size distribution and high quality crystallinity have been achieved through selected nucleation and growth conditions. High resolution transmission electron microscopy images and electron energy loss spectroscopy analysis confirm the expected structure and composition and show that similar crystal faceting has been formed in both synthetic approaches. The spinel nanoparticles behave as ferrimagnets with a high saturation magnetization and are superparamagnetic at room temperature. The influence of synthesis route on phase purity and unconventional magnetic properties is discussed in some particular cases such as CuFe 2 O 4 , CoFe 2 O 4 , and ZnFe 2 O 4 .

  1. Ions in solution basic principles of chemical interactions

    CERN Document Server

    Burgess, J

    1999-01-01

    This outline of the principles and chemical interactions in inorganic solution chemistry delivers a course module in an area of considerable complexity. Problems with solutions and tutorial hints to test comprehension have been added as a feature to check readers' understanding and assist self-study. Exercises and projects are also provided to help readers deepen and extend their knowledge and understanding. Inorganic solution chemistry is treated thoroughly Emphasis is placed upon NMR, UV-VIS, IR Raman spectroscopy, X-ray diffraction, and such topics as acid-base behaviour, stability constants and kinetics.

  2. PENINGKATAN KUALITAS PERKULIAHAN SOLUSI DERET MELALUI PENDEKATAN TEACHING ASSISTANT

    Directory of Open Access Journals (Sweden)

    - Masturi

    2016-09-01

    Full Text Available Kurangnya aktivitas belajar dan rendahnya nilai yang diperoleh mahasiswa dalam perkuliahan solusi deret merupakan masalahpembelajaran yang harus dipecahkan. Penelitian ini dilakukan untuk melihat sejauh mana pengaruh penerapan pendekatanteaching assistant dapat meningkatkan kualitas perkuliahan solusi deret. Subyek penelitian ini adalah mahasiswa PendidikanFisika UNNES. Penelitian ini dilakukan di Jurusan Fisika UNNES dengan desain penelitian tindakan kelas dua siklus. Instrumenyang digunakan adalah instrumen aktivitas yang meliputi: motivasi belajar, intensitas belajar dan interaksi belajar dan instrumenprestasi untuk mengukur hasil belajar. Dari penelitian ini didapatkan bahwa asistensi dapat meningkatkan aktivitas dan prestasibelajar. Hal itu terlihat dari 50 mahasiswa yang diberi tindakan, aktivitas belajar mereka pada siklus I dan II berada pada kategoribaik. Dari hasil observasi selama perkuliahan didapatkan adanya peningkatan intensitas pengerjaan tugas dan kuis. Nilai yangdiperoleh, dari siklus I ke siklus II mengalami peningkatan dari 65 menjadi 71. Dengan demikian, pendekatan teaching assistantterbukti dapat meningkatkan kualitas perkuliahan solusi deret. In this research, the effects of teaching assistant approach on the improvement of lecture quality of series solution topic wereinvestigated. The classroom action research with two cycles was set in physics education program. Some instruments that used toexplore the students activities were learning motivation, learning intensity, and learning interaction. Achievement instrument isused to measure the students' achievement. The results of the research show that teaching assistant can improve the students'activity as well as their achievement. It can be seen from the increasing activity of 50 students with good category from cycle one tothe second one. The observation results show that there is a significant improvement in intensity of students' interest in doing thetasks and quizzes

  3. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  4. Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Lu Xingqi; Mahadevan, Anand; Mathiowitz, George; Lin, Pei-Jan P.; Thomas, Ajith; Kasper, Ekkehard M.; Floyd, Scott R.; Holupka, Edward; La Rosa, Salvatore; Wang, Frank; Stevenson, Mary Ann

    2012-01-01

    Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient’s skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this “virtual frame” approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality

  5. Microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock

    Energy Technology Data Exchange (ETDEWEB)

    Akinlua, A., E-mail: geochemresearch@yahoo.com [Fossil Fuels and Environmental Geochemistry Group, Department of Chemistry, Obafemi Awolowo University, Ile-Ife (Nigeria); Jochmann, M.A.; Laaks, J.; Ewert, A.; Schmidt, T.C. [Instrumental Analytical Chemistry, University Duisburg-Essen, Universitaetsstr, 5, 45141 Essen (Germany)

    2011-04-08

    The extraction of aliphatic hydrocarbons from petroleum source rock using nonionic surfactants with the assistance of microwave was investigated and the conditions for maximum yield were determined. The results showed that the extraction temperatures and kinetic rates have significant effects on extraction yields of aliphatic hydrocarbons. The optimum temperature for microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock was 105 deg. C. The optimum extraction time for the aliphatic hydrocarbons was at 50 min. Concentration of the nonionic surfactant solution and irradiation power had significant effect on the yields of aliphatic hydrocarbons. The yields of the analytes were much higher using microwave assisted nonionic surfactant extraction than with Soxhlet extraction. The recoveries of the n-alkanes and acyclic isoprenoid hydrocarbons for GC-MS analysis from the extractant nonionic surfactant solution by in-tube extraction (ITEX 2) with a TENAX TA adsorbent were found to be efficient. The results show that microwave-assisted nonionic surfactant extraction (MANSE) is a good and efficient green analytical preparatory technique for geochemical evaluation of petroleum source rock.

  6. Microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock

    International Nuclear Information System (INIS)

    Akinlua, A.; Jochmann, M.A.; Laaks, J.; Ewert, A.; Schmidt, T.C.

    2011-01-01

    The extraction of aliphatic hydrocarbons from petroleum source rock using nonionic surfactants with the assistance of microwave was investigated and the conditions for maximum yield were determined. The results showed that the extraction temperatures and kinetic rates have significant effects on extraction yields of aliphatic hydrocarbons. The optimum temperature for microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock was 105 deg. C. The optimum extraction time for the aliphatic hydrocarbons was at 50 min. Concentration of the nonionic surfactant solution and irradiation power had significant effect on the yields of aliphatic hydrocarbons. The yields of the analytes were much higher using microwave assisted nonionic surfactant extraction than with Soxhlet extraction. The recoveries of the n-alkanes and acyclic isoprenoid hydrocarbons for GC-MS analysis from the extractant nonionic surfactant solution by in-tube extraction (ITEX 2) with a TENAX TA adsorbent were found to be efficient. The results show that microwave-assisted nonionic surfactant extraction (MANSE) is a good and efficient green analytical preparatory technique for geochemical evaluation of petroleum source rock.

  7. The Role of Social Assistance on Effectiveness of Social Rights

    Directory of Open Access Journals (Sweden)

    João Guilherme Sampaio dos Anjos

    2016-10-01

    Full Text Available The social assistance has intrinsic historical, legal and political relationship to social rights. Fundamental rights have assumed a legal-constitutional role since the mid-twentieth century. Through historical and doctrinal review of fundamental rights and social welfare, the identification of legal frameworks and institutional instruments of social assistance that demonstrate their ability to contribute to the realization of social rights and the problem of realization of social rights, social assistance seems to be able to play a prominent role as a public policy that helps to point out a solution to the problem of lack of effectiveness of social rights.

  8. Computer assisted procedure maintenance

    International Nuclear Information System (INIS)

    Bisio, R.; Hulsund, J. E.; Nilsen, S.

    2004-04-01

    The maintenance of operating procedures in a NPP is a tedious and complicated task. Through the whole life cycle of the procedures they will be dynamic, 'living' documents. Several aspects of the procedure must be considered in a revision process. Pertinent details and attributes of the procedure must be checked. An organizational structure must be created and responsibilities allotted for drafting, revising, reviewing and publishing procedures. Available powerful computer technology provides solutions within document management and computerisation of procedures. These solutions can also support the maintenance of procedures. Not all parts of the procedure life cycle are equally amenable to computerized support. This report looks at the procedure life cycle in todays NPPs and discusses the possibilities associated with introduction of computer technology to assist the maintenance of procedures. (Author)

  9. Slope stability and erosion control: Ecotechnological solutions

    NARCIS (Netherlands)

    Norris, J.E.; Stokes, A.; Mickovski, S.B.; Cammeraat, E.; van Beek, R.; Nicoll, B.C.; Achim, A.

    2008-01-01

    This book is designed to assist the civil and geotechnical engineer, geomorphologist, forester, landscape architect or ecologist in choosing ecotechnological solutions for slopes that are prone to a variety of mass movements e.g. shallow failure or erosion. Within this book, the 'engineer' is used

  10. Promoting Savings at Tax Time through a Video-Based Solution-Focused Brief Coaching Intervention

    Directory of Open Access Journals (Sweden)

    Lance Palmer

    2016-09-01

    Full Text Available Solution-focused brief coaching, based on solution-focused brief therapy, is a well-established practice model and is used widely to help individuals progress toward desired outcomes in a variety of settings. This papers presents the findings of a pilot study that examined the impact of a video-based solution-focused brief coaching intervention delivered in conjunction with income tax preparation services at a Volunteer Income Tax Assistance location (n = 212. Individuals receiving tax preparation assistance were randomly assigned to one of four treatment groups: 1 control group; 2 video-based solution-focused brief coaching; 3 discount card incentive; 4 both the video-based solution-focused brief coaching and the discount card incentive. Results of the study indicate that the video-based solution-focused brief coaching intervention increased both the frequency and amount of self-reported savings at tax time. Results also indicate that financial therapy based interventions may be scalable through the use of technology.

  11. Preoperative examination of potential renal transplant donors: value of gadolinium-enhanced 3D-MR-angiography in comparison with DSA and urography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Paul, G.; Einert, A.; Altehoefer, C.; Uhrmeister, P.; Laubenberger, J.

    2000-01-01

    Purpose: To assess a contrast-enhanced standardized MRA protocol for the presurgical evaluation of potential renal transplant donors. Methods: Twenty-three potential donors for renal transplantations were examined with gadolinium-enhanced, two-phase MR angiograms (1.5 T) and DSA/urography for the number of renal arteries, the presence of aberrant arterial and venous branches, renal artery stenoses and anatomy of the renal collecting system and ureters. The diagnostic value was assessed by evaluating different image processing modalities and interobserver variability. Results: Using maximum intensity projections (MIP) together with multiplanar reformatting (MPR), accessory arteries were detected with a sensitivity/specificity of 100%/98%. Depending on diagnostic experience, exclusive evaluation of MIP yielded a sensitivitiy/specificity of 67-100%/95-100%. Using MIP/MPR, venous depiction was good in 80%, with MIP solely in 30-40%. At least the proximal third of the ureter was visible in 67%. Conclusion: MPR/MIP evaluation of two-phase, contrast-enhanced MRA provides an excellent depiction of renal vessel anatomy for presurgical evaluation of renal transplant donors. Exclusive MIP assessment is less reliable and depends strongly on the examiner's experience. For sufficient visualization of the ureters, either additional measurements or low-dose diuretic injection have to be performed. (orig.) [de

  12. Directed Self-Assembly of Triblock Copolymer on Chemical Patterns for Sub-10-nm Nanofabrication via Solvent Annealing.

    Science.gov (United States)

    Xiong, Shisheng; Wan, Lei; Ishida, Yoshihito; Chapuis, Yves-Andre; Craig, Gordon S W; Ruiz, Ricardo; Nealey, Paul F

    2016-08-23

    Directed self-assembly (DSA) of block copolymers (BCPs) is a leading strategy to pattern at sublithographic resolution in the technology roadmap for semiconductors and is the only known solution to fabricate nanoimprint templates for the production of bit pattern media. While great progress has been made to implement block copolymer lithography with features in the range of 10-20 nm, patterning solutions below 10 nm are still not mature. Many BCP systems self-assemble at this length scale, but challenges remain in simultaneously tuning the interfacial energy atop the film to control the orientation of BCP domains, designing materials, templates, and processes for ultra-high-density DSA, and establishing a robust pattern transfer strategy. Among the various solutions to achieve domains that are perpendicular to the substrate, solvent annealing is advantageous because it is a versatile method that can be applied to a diversity of materials. Here we report a DSA process based on chemical contrast templates and solvent annealing to fabricate 8 nm features on a 16 nm pitch. To make this possible, a number of innovations were brought in concert with a common platform: (1) assembling the BCP in the phase-separated, solvated state, (2) identifying a larger process window for solvated triblock vs diblock BCPs as a function of solvent volume fraction, (3) employing templates for sub-10-nm BCP systems accessible by lithography, and (4) integrating a robust pattern transfer strategy by vapor infiltration of organometallic precursors for selective metal oxide synthesis to prepare an inorganic hard mask.

  13. Principles for fostering the transdisciplinary development of assistive technologies.

    Science.gov (United States)

    Boger, Jennifer; Jackson, Piper; Mulvenna, Maurice; Sixsmith, Judith; Sixsmith, Andrew; Mihailidis, Alex; Kontos, Pia; Miller Polgar, Janice; Grigorovich, Alisa; Martin, Suzanne

    2017-07-01

    Developing useful and usable assistive technologies often presents complex (or "wicked") challenges that require input from multiple disciplines and sectors. Transdisciplinary collaboration can enable holistic understanding of challenges that may lead to innovative, impactful and transformative solutions. This paper presents generalised principles that are intended to foster transdisciplinary assistive technology development. The paper introduces the area of assistive technology design before discussing general aspects of transdisciplinary collaboration followed by an overview of relevant concepts, including approaches, methodologies and frameworks for conducting and evaluating transdisciplinary working and assistive technology design. The principles for transdisciplinary development of assistive technologies are presented and applied post hoc to the COACH project, an ambient-assisted living technology for guiding completion of activities of daily living by older adults with dementia as an illustrative example. Future work includes the refinement and validation of these principles through their application to real-world transdisciplinary assistive technology projects. Implications for rehabilitation Transdisciplinarity encourages a focus on real world 'wicked' problems. A transdisciplinary approach involves transcending disciplinary boundaries and collaborating with interprofessional and community partners (including the technology's intended users) on a shared problem. Transdisciplinarity fosters new ways of thinking about and doing research, development, and implementation, expanding the scope, applicability, and commercial viability of assistive technologies.

  14. Monodisperse Silver Nanoparticles Synthesized by a Microwave-Assisted Method

    International Nuclear Information System (INIS)

    Shao-Peng, Zhu; Shao-Chun, Tang; Xiang-Kang, Meng

    2009-01-01

    Silver nanoparticles with an average size of about 20 nm are synthesized in a colloidal solution with the aid of microwave irradiation. Neither additional reductant nor stabilizer is required in this microwave-assisted method. The color of the colloidal solution is found to be dark green, different from the characteristic yellow of silver colloidal solutions. The silver nanoparticles in the colloidal solution have a narrow size distribution and large yield quantity. UV-visible absorption spectroscopy analysis reveals that the as-synthesized monodisperse silver nanoparticles have exceptional optical properties. Raman spectroscopy measurements demonstrate that these silver nanoparticles exhibit a notable surface-enhanced Raman scattering ability. (cross-disciplinary physics and related areas of science and technology)

  15. Facile solution-precipitation assisted synthesis and luminescence property of greenish-yellow emitting Ca{sub 6}Ba(PO{sub 4}){sub 4}O:Eu{sup 2+} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Haipeng [School of Materials Science and Technology, Beijing Key Laboratory of Materials Utilization of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, China University of Geosciences, Beijing 100083 (China); Huang, Zhaohui, E-mail: huang118@cugb.edu.cn [School of Materials Science and Technology, Beijing Key Laboratory of Materials Utilization of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, China University of Geosciences, Beijing 100083 (China); Xia, Zhiguo, E-mail: xiazg@ustb.edu.cn [The Beijing Municipal Key Laboratory of New Energy Materials and Technologies, School of Materials Sciences and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Xie, Yao [School of Materials Science and Technology, Beijing Key Laboratory of Materials Utilization of Nonmetallic Minerals and Solid Wastes, National Laboratory of Mineral Materials, China University of Geosciences, Beijing 100083 (China); Molokeev, Maxim S. [Laboratory of Crystal Physics, Kirensky Institute of Physics, SB RAS, Krasnoyarsk 660036 (Russian Federation); Department of Physics, Far Eastern State Transport University, Khabarovsk 680021 (Russian Federation); Atuchin, Victor V. [Laboratory of Optical Materials and Structures, Institute of Semiconductor Physics, SB RAS, Novosibirsk 630090 (Russian Federation); Functional Electronics Laboratory, Tomsk State University, Tomsk 634050 (Russian Federation); Laboratory of Semiconductor and Dielectric Materials, Novosibirsk State University, Novosibirsk 630090 (Russian Federation)

    2016-03-15

    Highlights: • Ca{sub 6}Ba(PO{sub 4}){sub 4}O:Eu{sup 2+} phosphor was prepared by the solution-precipitation assisted route. • The phosphors have satisfactory smooth grain surface and particle size. • It shows greenish-yellow color emission (maximum at 540 nm) upon blue light excitation. • Eu{sup 2+} is coordinated with isolated oxygen atoms and those from PO{sub 4} polyhedra. - Abstract: Greenish-yellow emitting microcrystalline Ca{sub 6}Ba(PO{sub 4}){sub 4}O:Eu{sup 2+} phosphor was successfully prepared by a solution-precipitation assisted high temperature reaction method. Phase structure, morphology and/or luminescence properties of the precursor and the as-prepared phosphors were characterized. The phase-pure Ca{sub 6}Ba(PO{sub 4}){sub 4}O:Eu{sup 2+} phosphors were obtained with smooth grain surface and particle size of 2–8 μm. Ca{sub 6}Ba(PO{sub 4}){sub 4}O:Eu{sup 2+} exhibits bright greenish-yellow color emission with its maximum at 540 nm upon UV-blue light excitation. The maximum position of the broad emission band is independent on the calcination temperature. The emission intensity increases with increasing calcination temperature due to improved crystallinity. Besides, the presence of two Eu{sup 2+} emission centers in the Ca{sub 6}Ba(PO{sub 4}){sub 4}O crystal lattice was confirmed and the coordination effects are considered concerning the roles of isolated O atoms and those from the PO{sub 4} tetrahedra.

  16. Nonsolvent-assisted fabrication of multi-scaled polylactide as superhydrophobic surfaces.

    Science.gov (United States)

    Chang, Yafang; Liu, Xuying; Yang, Huige; Zhang, Li; Cui, Zhe; Niu, Mingjun; Liu, Hongzhi; Chen, Jinzhou

    2016-03-14

    The solution-processing fabrication of superhydrophobic surfaces is currently intriguing, owing to high-efficiency, low cost, and energy-consuming. Here, a facile nonsolvent-assisted process was proposed for the fabrication of the multi-scaled surface roughness in polylactide (PLA) films, thereby resulting in a significant transformation in the surface wettability from intrinsic hydrophilicity to superhydrophobicity. Moreover, it was found that the surface topographical structure of PLA films can be manipulated by varying the compositions of the PLA solutions. And the samples showed superhydrophobic surfaces as well as high melting enthalpy and crystallinity. In particular, a high contact angle of 155.8° together with a high adhesive force of 184 μN was yielded with the assistance of a multi-nonsolvent system, which contributed to the co-existence of micro-/nano-scale hierarchical structures.

  17. Granular activated carbon assisted ozonation of cephalexin antibiotic

    International Nuclear Information System (INIS)

    Akhtar, J.; Amin, N.S.; Imran, M.

    2016-01-01

    This study investigates removal of cephalexin using ozonation in the presence of granular activated carbon. Initial experiments were carried out about adsorption of cephalexin onto granular activated carbon, effect of catalytic ozonation, and biodegradability of cephalexin solution. The effect of ozonation on pH, ozone utilization efficiency and decomposition byproducts, was observed. Response surface methodology was adopted to optimize three operating parameters pH of solution, ozone supply and cephalexin concentration. GAC assisted ozonation, was found to be effective in decomposing COD (chemical oxygen demand) and cephalexin from solution. Optimum values of variables were pH from 7-8, ozone supply 30 mg/L and 100 mg/L of cephalexin solution. The complete removal of cephalexin and 60% COD removal was achieved at these optimum input values. (author)

  18. The linear characteristic method for spatially discretizing the discrete ordinates equations in (x,y)-geometry

    International Nuclear Information System (INIS)

    Larsen, E.W.; Alcouffe, R.E.

    1981-01-01

    In this article a new linear characteristic (LC) spatial differencing scheme for the discrete ordinates equations in (x,y)-geometry is described and numerical comparisons are given with the diamond difference (DD) method. The LC method is more stable with mesh size and is generally much more accurate than the DD method on both fine and coarse meshes, for eigenvalue and deep penetration problems. The LC method is based on computations involving the exact solution of a cell problem which has spatially linear boundary conditions and interior source. The LC method is coupled to the diffusion synthetic acceleration (DSA) algorithm in that the linear variations of the source are determined in part by the results of the DSA calculation from the previous inner iteration. An inexpensive negative-flux fixup is used which has very little effect on the accuracy of the solution. The storage requirements for LC are essentially the same as that for DD, while the computational times for LC are generally less than twice the DD computational times for the same mesh. This increase in computational cost is offset if one computes LC solutions on somewhat coarser meshes than DD; the resulting LC solutions are still generally much more accurate than the DD solutions. (orig.) [de

  19. "Learning to Assess" and "Assessing to Learn": The Construction of Knowledge about Assistive Technology

    Science.gov (United States)

    Folkes, Clare; Carmichael, Patrick

    2006-01-01

    A key role in the development and deployment of Assistive Technology solutions is that of the "assessor-consultant". Assessor-consultants for the UK-based charity Abilitynet work with clients to develop customized computer-based assistive technology systems and draw on a range of shared knowledge from the assessor-consultant community.…

  20. CO and C_3H_8 Sensitivity Behavior of Zinc Antimonate Prepared by a Microwave-Assisted Solution Method

    International Nuclear Information System (INIS)

    Guillen-Bonilla, H.; Rodiguez Betancourtt, V. M.; Flores-Martinez, M.; Guillen-Bonilla, J. T.; Reyes-Gomez, J.; Gildo-Ortiz, L.; Olvera-Amador, M. L.; Santoyo-Salazar, J.

    2015-01-01

    ZnSb_2O_6 has been synthesized by a microwave-assisted solution method in order to test its possible application as a gas sensor. Zinc nitrate, antimony trichloride, and ethylenediamine were used as precursors and deionized water as solvent. Microwave radiation, with a power of "approx"350 W, was applied for solvent evaporation. The thermal decomposition of the precursors leads to the formation of ZnSb_2O_6 at 600 degree. This oxide crystallized in a tetragonal structure with cell parameters a=4.66 angstrom sign, c=9.26 angstrom sign and space group P4_2/ mnm. Micro wires and micro rods formed by nano crystals were observed by means of scanning and transmission electron micros copies (SEM and TEM, resp.). Pellets of the oxide were tested as gas sensors in flowing atmospheres of carbon monoxide (CO) and propane (C_3H_8). Sensitivity increased with the gas concentration (0-300 ppm) and working temperatures (ambient, 150 and 250 degree) increase. The results indicate high sensitivity of ZnSb_2O_6 in both gases at different concentrations and operating temperatures.

  1. CO and C3H8 Sensitivity Behavior of Zinc Antimonate Prepared by a Microwave-Assisted Solution Method

    Directory of Open Access Journals (Sweden)

    Héctor Guillen-Bonilla

    2015-01-01

    Full Text Available ZnSb2O6 has been synthesized by a microwave-assisted solution method in order to test its possible application as a gas sensor. Zinc nitrate, antimony trichloride, and ethylenediamine were used as precursors and deionized water as solvent. Microwave radiation, with a power of ~350 W, was applied for solvent evaporation. The thermal decomposition of the precursors leads to the formation of ZnSb2O6 at 600°C. This oxide crystallized in a tetragonal structure with cell parameters a=4.66 Å, c=9.26 Å and space group P42/mnm. Microwires and microrods formed by nanocrystals were observed by means of scanning and transmission electron microscopies (SEM and TEM, resp.. Pellets of the oxide were tested as gas sensors in flowing atmospheres of carbon monoxide (CO and propane (C3H8. Sensitivity increased with the gas concentration (0–300 ppm and working temperatures (ambient, 150 and 250°C increase. The results indicate high sensitivity of ZnSb2O6 in both gases at different concentrations and operating temperatures.

  2. Social information solution; Shakai joho solution

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    An information system for government offices is developed, a system that integrally supports operations inside government offices and the staff service operations by combining Intra Net as the basis of an information system with Internet. The objective of the system is as follows: (1) Information sharing in the place of work and utilization of information resources. (2) Improvement in administrative services and vitalization of an interchange of residents through the preparation of Internet environment. (3) Rationalization of staff operations through groupeware. In addition, by building a network system for the entire region, information communication service is to be provided as a solution between the residents and the administration in the occurrence of a disaster as well as for home care, medical and nursing assistance in the health, medical and welfare fields. (translated by NEDO)

  3. Temperature-assisted solute focusing with sequential trap/release zones in isocratic and gradient capillary liquid chromatography: Simulation and experiment

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2016-01-01

    In this work we characterize the development of a method to enhance temperature-assisted on-column solute focusing (TASF) called two-stage TASF. A new instrument was built to implement two-stage TASF consisting of a linear array of three independent, electronically controlled Peltier devices (thermoelectric coolers, TECs). Samples are loaded onto the chromatographic column with the first two TECs, TEC A and TEC B, cold. In the two-stage TASF approach TECs A and B are cooled during injection. TEC A is heated following sample loading. At some time following TEC A’s temperature rise, TEC B’s temperature is increased from the focusing temperature to a temperature matching that of TEC A. Injection bands are focused twice on-column, first on the initial TEC, e.g. single-stage TASF, then refocused on the second, cold TEC. Our goal is to understand the two-stage TASF approach in detail. We have developed a simple yet powerful digital simulation procedure to model the effect of changing temperature in the two focusing zones on retention, band shape and band spreading. The simulation can predict experimental chromatograms resulting from spatial and temporal temperature programs in combination with isocratic and solvent gradient elution. To assess the two-stage TASF method and the accuracy of the simulation well characterized solutes are needed. Thus, retention factors were measured at six temperatures (25–75 °C) at each of twelve mobile phases compositions (0.05–0.60 acetonitrile/water) for homologs of n-alkyl hydroxylbenzoate esters and n-alkyl p-hydroxyphenones. Simulations accurately reflect experimental results in showing that the two-stage approach improves separation quality. For example, two-stage TASF increased sensitivity for a low retention solute by a factor of 2.2 relative to single-stage TASF and 8.8 relative to isothermal conditions using isocratic elution. Gradient elution results for two-stage TASF were more encouraging. Application of two-stage TASF

  4. Committee-Based Active Learning for Surrogate-Assisted Particle Swarm Optimization of Expensive Problems.

    Science.gov (United States)

    Wang, Handing; Jin, Yaochu; Doherty, John

    2017-09-01

    Function evaluations (FEs) of many real-world optimization problems are time or resource consuming, posing a serious challenge to the application of evolutionary algorithms (EAs) to solve these problems. To address this challenge, the research on surrogate-assisted EAs has attracted increasing attention from both academia and industry over the past decades. However, most existing surrogate-assisted EAs (SAEAs) either still require thousands of expensive FEs to obtain acceptable solutions, or are only applied to very low-dimensional problems. In this paper, a novel surrogate-assisted particle swarm optimization (PSO) inspired from committee-based active learning (CAL) is proposed. In the proposed algorithm, a global model management strategy inspired from CAL is developed, which searches for the best and most uncertain solutions according to a surrogate ensemble using a PSO algorithm and evaluates these solutions using the expensive objective function. In addition, a local surrogate model is built around the best solution obtained so far. Then, a PSO algorithm searches on the local surrogate to find its optimum and evaluates it. The evolutionary search using the global model management strategy switches to the local search once no further improvement can be observed, and vice versa. This iterative search process continues until the computational budget is exhausted. Experimental results comparing the proposed algorithm with a few state-of-the-art SAEAs on both benchmark problems up to 30 decision variables as well as an airfoil design problem demonstrate that the proposed algorithm is able to achieve better or competitive solutions with a limited budget of hundreds of exact FEs.

  5. Diagnostic value of the digital subtraction angiography of brain tumors. With special reference to the significance of tumor stains

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Yoshifumi; Matsukado, Yasuhiko; Takahashi, Mutsumasa

    1986-10-01

    Digital subtraction angiography (DSA) in 110 cases of brain tumors were studied in comparison with conventional angiography (CA). The dural sinuses and tumor stains of meningiomas, particularly tuberculum sellae meningioma, were better shown by intravenous DSA (IV-DSA) than by CA. IV-DSA clearly demonstrated bilateral carotid arteries and was able to rule out the coexistence of the intracranial aneurysm in 88 % of 32 cases with pituitary adenomas. Combination of IV-DSA and high resolution computed tomography has replaced CA to determine surgical indication of patients with pituitary adenomas. Intra-arterial DSA (IA-DSA) was diagnostic and well comparable to CA in identifying main cerebral vasculature over 1 mm in diameter. As to the small arteries under 1 mm and fine tumor vessels, IA-DSA provided less information or none at all. However, IA-DSA was superior to CA for visualization of tumor stains. Not only in most of meningiomas and hemangioblastomas, but in some astrocytomas and oligodendrogliomas, marked tumor stains were well demonstrated on DSA, and DSA provided surgical anatomy for neurosurgeons because of high contrast resolutions. Careful attention should be paid because tumor stains may overestimate tumor vascularity.

  6. Solar Assisted Ground Source Heat Pump Performance in Nearly Zero Energy Building in Baltic Countries

    Science.gov (United States)

    Januševičius, Karolis; Streckienė, Giedrė

    2013-12-01

    In near zero energy buildings (NZEB) built in Baltic countries, heat production systems meet the challenge of large share domestic hot water demand and high required heating capacity. Due to passive solar design, cooling demand in residential buildings also needs an assessment and solution. Heat pump systems are a widespread solution to reduce energy use. A combination of heat pump and solar thermal collectors helps to meet standard requirements and increases the share of renewable energy use in total energy balance of country. The presented paper describes a simulation study of solar assisted heat pump systems carried out in TRNSYS. The purpose of this simulation was to investigate how the performance of a solar assisted heat pump combination varies in near zero energy building. Results of three systems were compared to autonomous (independent) systems simulated performance. Different solar assisted heat pump design solutions with serial and parallel solar thermal collector connections to the heat pump loop were modelled and a passive cooling possibility was assessed. Simulations were performed for three Baltic countries: Lithuania, Latvia and Estonia.

  7. Reducing multiple births in assisted reproduction technology.

    Science.gov (United States)

    Bhattacharya, Siladitya; Kamath, Mohan S

    2014-02-01

    Multiple pregnancy, a complication of assisted reproduction technology, is associated with poorer maternal and perinatal outcomes. The primary reason behind this is the strategy of replacing more than one embryo during an assisted reproduction technology cycle to maximise pregnancy rates. The solution to this problem is to reduce the number of embryos transferred during in-vitro fertilisation. The transition from triple- to double-embryo transfer, which decreased the risk of triplets without compromising pregnancy rates, was easily implemented. The adoption of a single embryo transfer policy has been slow because of concerns about impaired pregnancy rates in a fresh assisted reproduction technology cycle. Widespread availability of effective cryopreservation programmes means that elective single embryo transfer, along with subsequent frozen embryo transfers, could provide a way forward. Any such strategy will need to consider couples' preferences and existing funding policies, both of which have a profound influence on decision making around embryo transfer. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Generalized instantly decodable network coding for relay-assisted networks

    KAUST Repository

    Elmahdy, Adel M.

    2013-09-01

    In this paper, we investigate the problem of minimizing the frame completion delay for Instantly Decodable Network Coding (IDNC) in relay-assisted wireless multicast networks. We first propose a packet recovery algorithm in the single relay topology which employs generalized IDNC instead of strict IDNC previously proposed in the literature for the same relay-assisted topology. This use of generalized IDNC is supported by showing that it is a super-set of the strict IDNC scheme, and thus can generate coding combinations that are at least as efficient as strict IDNC in reducing the average completion delay. We then extend our study to the multiple relay topology and propose a joint generalized IDNC and relay selection algorithm. This proposed algorithm benefits from the reception diversity of the multiple relays to further reduce the average completion delay in the network. Simulation results show that our proposed solutions achieve much better performance compared to previous solutions in the literature. © 2013 IEEE.

  9. Application of ionic liquids based enzyme-assisted extraction of chlorogenic acid from Eucommia ulmoides leaves

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tingting; Sui, Xiaoyu, E-mail: suixiaoyu@outlook.com; Li, Li; Zhang, Jie; Liang, Xin; Li, Wenjing; Zhang, Honglian; Fu, Shuang

    2016-01-15

    A new approach for ionic liquid based enzyme-assisted extraction (ILEAE) of chlorogenic acid (CGA) from Eucommia ulmoides is presented in which enzyme pretreatment was used in ionic liquids aqueous media to enhance extraction yield. For this purpose, the solubility of CGA and the activity of cellulase were investigated in eight 1-alkyl-3-methylimidazolium ionic liquids. Cellulase in 0.5 M [C6mim]Br aqueous solution was found to provide better performance in extraction. The factors of ILEAE procedures including extraction time, extraction phase pH, extraction temperatures and enzyme concentrations were investigated. Moreover, the novel developed approach offered advantages in term of yield and efficiency compared with other conventional extraction techniques. Scanning electronic microscopy of plant samples indicated that cellulase treated cell wall in ionic liquid solution was subjected to extract, which led to more efficient extraction by reducing mass transfer barrier. The proposed ILEAE method would develope a continuous process for enzyme-assisted extraction including enzyme incubation and solvent extraction process. In this research, we propose a novel view for enzyme-assisted extraction of plant active component, besides concentrating on enzyme facilitated cell wall degradation, focusing on improvement of bad permeability of ionic liquids solutions. - Highlights: • An ionic liquid based enzyme-assisted extraction method of natural product was explored. • ILEAE utilizes enzymatic treatment to improve permeability of ionic liquids solution. • Enzyme incubation and solvent extraction process were ongoing simultaneously. • ILEAE process simplified operating process and suitable for more complete extraction.

  10. Application of ionic liquids based enzyme-assisted extraction of chlorogenic acid from Eucommia ulmoides leaves

    International Nuclear Information System (INIS)

    Liu, Tingting; Sui, Xiaoyu; Li, Li; Zhang, Jie; Liang, Xin; Li, Wenjing; Zhang, Honglian; Fu, Shuang

    2016-01-01

    A new approach for ionic liquid based enzyme-assisted extraction (ILEAE) of chlorogenic acid (CGA) from Eucommia ulmoides is presented in which enzyme pretreatment was used in ionic liquids aqueous media to enhance extraction yield. For this purpose, the solubility of CGA and the activity of cellulase were investigated in eight 1-alkyl-3-methylimidazolium ionic liquids. Cellulase in 0.5 M [C6mim]Br aqueous solution was found to provide better performance in extraction. The factors of ILEAE procedures including extraction time, extraction phase pH, extraction temperatures and enzyme concentrations were investigated. Moreover, the novel developed approach offered advantages in term of yield and efficiency compared with other conventional extraction techniques. Scanning electronic microscopy of plant samples indicated that cellulase treated cell wall in ionic liquid solution was subjected to extract, which led to more efficient extraction by reducing mass transfer barrier. The proposed ILEAE method would develope a continuous process for enzyme-assisted extraction including enzyme incubation and solvent extraction process. In this research, we propose a novel view for enzyme-assisted extraction of plant active component, besides concentrating on enzyme facilitated cell wall degradation, focusing on improvement of bad permeability of ionic liquids solutions. - Highlights: • An ionic liquid based enzyme-assisted extraction method of natural product was explored. • ILEAE utilizes enzymatic treatment to improve permeability of ionic liquids solution. • Enzyme incubation and solvent extraction process were ongoing simultaneously. • ILEAE process simplified operating process and suitable for more complete extraction.

  11. Risk and prevention of graft failure in patients with preexisting donor-specific HLA antibodies undergoing unmanipulated haploidentical SCT.

    Science.gov (United States)

    Yoshihara, S; Maruya, E; Taniguchi, K; Kaida, K; Kato, R; Inoue, T; Fujioka, T; Tamaki, H; Ikegame, K; Okada, M; Soma, T; Hayashi, K; Fujii, N; Onuma, T; Kusunoki, Y; Saji, H; Ogawa, H

    2012-04-01

    A role of donor-specific HLA antibodies (DSA) in graft failure after SCT has been suggested, but the relevance of DSA in unmanipulated haploidentical SCT (haplo-SCT) remains unknown. We prospectively examined HLA antibodies using the Luminex-based single Ag assay for 79 adult patients undergoing unmanipulated haplo-SCT. Among them, 16 (20.2%) were HLA Ab-positive, including five patients with antibodies not corresponding to donor HLA Ags and 11 DSA-positive patients. Of the 11 DSA-positive patients, five received treatments to decrease DSA levels, including two, who received plasma exchange and rituximab, two who received platelet transfusions from healthy-related donors having DSA-corresponding HLA Ags and one who received bortezomib. Platelet transfusion was the most simple and effective treatment option for class I DSA. The cumulative incidence of neutrophil recovery was significantly lower in pretransplant (post-treatment) DSA-positive patients than in DSA-negative patients (61.9 vs 94.4%, P=0.026). Notably, three of five patients with high levels of DSA had graft failure. Donors should be selected on the basis of an evaluation of HLA antibodies. If haplo-SCT from donors with HLA Ags that correspond to high levels of DSA must be performed, then recipients should be treated for DSA to improve the chances of successful donor engraftment.

  12. Activity recognition based on inertial sensors for ambient assisted living

    NARCIS (Netherlands)

    Davis, K.; Owusu, E.; Bastani, V.; Marcenaro, L.; Hu, J.; Regazzoni, C.; Feijs, L.M.G.

    2016-01-01

    Ambient Assisted Living (AAL) aims to create innovative technical solutions and services to support independent living among older adults, improve their quality of life and reduce the costs associated with health and social care. AAL systems provide health monitoring through sensor based

  13. Arm reduced robotic-assisted laparoscopic hysterectomy with transvaginal cuff closure.

    Science.gov (United States)

    Bodur, Serkan; Dede, Murat; Fidan, Ulas; Firatligil, Burcin F; Ulubay, Mustafa; Ozturk, Mustafa; Yenen, Mufit C

    2017-09-01

    The use of robotics for benign etiology in gynecology has not proven to be more beneficial when compared to traditional laparoscopy. The major concern regarding robotic hysterectomy stems from its high cost. To evaluate the clinical utility and effectiveness of one-arm reduced robotic-assisted laparoscopic hysterectomy as a cost-effective surgical option for total robotic hysterectomy. A sample population of 54 women who underwent robotic-assisted laparoscopic surgery for benign gynecologic indications was evaluated, and two groups were identified: (1) the two-armed robotic-assisted laparoscopic surgery group (n = 38 patients), and (2) the three-armed robotic-assisted laparoscopic surgery group (n = 16 patients). An increased cost was observed when three-armed robotic surgery was employed for benign gynecologic surgery (p < 0.001). The cost reduction observed in the study group was primarily derived from one robotic arm reduction and vaginal closure of the cuff. This cost reduction was achieved without an increase in complication rates or undesirable postoperative outcomes. An estimated profit between $399.5 and $421.5 was made for each patient depending on the suture material chosen for cuff closure. Two-armed surgery resulted in an 18.6% reduction in procedure-specific costs for robotic hysterectomy. Two-armed robotic-assisted laparoscopic hysterectomy appears to be a cost-effective solution for robotic gynecologic surgery. This surgical solution can be performed as effectively as classical three-armed robotic hysterectomies for benign indications without the risk of increased surgical-related morbidities. This approach has the potential to be a widely preferred surgical approach in medical communities where cost reduction is one of the primary determinants of surgery type.

  14. Evaluation of a small socially-assistive humanoid robot in intelligent homes for the care of the elderly.

    NARCIS (Netherlands)

    Torta, E.; Werner, F.; Johnson, D.O.; Juola, J.F.; Cuijpers, R.H.; Bazzani, M.; Oberzaucher, J.; Lemberger, J.

    2014-01-01

    The ageing population phenomenon is pushing the design of innovative solutions to provide assistance to the elderly. In this context a socially–assistive robot can act as a proactive interface in a smart-home environment, providing multimodal communication channels and generating positive feelings

  15. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  16. Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms.

    Science.gov (United States)

    Qin, Feiyun; Li, Zhenbao; Fang, Xinggen; Zhao, Xintong; Liu, Jiaqiang; Wu, Degang; Lai, Niansheng

    2017-08-01

    Enterprise stent has been widespread used in wide-necked intracranial aneurysms and good efficacy has been achieved, but there are few reports on its applications in very small ruptured intracranial aneurysms in literatures. This study aimed to evaluate the safety and efficacy of Enterprise stent-assisted coiling embolization of very small ruptured intracranial aneurysms.We retrospectively reviewed the clinical and imaging data from 37 patients with very small ruptured intracranial aneurysms who had SAC using Enterprise stents performed from February 2012 to July 2016 in our department. Data collected and analyzed included patient demographics, morphologic features of the aneurysm, treatment results, and follow-up results. Clinical outcomes were evaluated by the Glasgow Outcome Scale (GOS).Enterprise stents were successfully implanted in all 37 patients with very small ruptured intracranial aneurysms. Of the 37 individuals, 28 patients exhibited complete occlusion at Raymond grade I, 5 patients exhibited occlusion at Raymond grade II, and 4 patients at Raymond grade III. Procedure-related complications occurred in 3 of 37 patients (8.1%), including 1 case of intraprocedure aneurysm rupture who died from cerebral herniation caused by severe postoperative cerebral ischemia during the hospital stay, and the other 2 complications were acute in-stent thrombosis, and occlusion of parent artery caused by falling-off internal carotid artery plaque, respectively. A total of 36 patients underwent postoperative clinical follow-up visits for 6 to 24 months of which 31 patients recovered (GOS ≥ 4). One patient had hemiplegic paralysis, and no rehemorrhage was found. A total of 25 patients underwent follow-up digital subtraction angiography (DSA) at 3-21 months postintervention, in whom there were 22 cases with complete occlusion, 2 cases with recurrence of aneurysm neck, and 1 case with in-stent restenosis, but there was no patient with neurologic deficits.The Enterprise

  17. Degradation of Para-Phenylenediamine in Aqueous Solution by ...

    African Journals Online (AJOL)

    In this research Photo-Fenton Oxidation of Para-Phenylenediamine (PPD) in aqueous solution by UV/Fenton's reagent (Fe2+ and H2O2) was investigated. ... lower concentration of Phenylenediamines and UV-C assisted photo-Fenton showed that the photo-Fenton process was very effective than the normal Fenton process ...

  18. Evanescent wave assisted nanomaterial coating.

    Science.gov (United States)

    Mondal, Samir K; Pal, Sudipta Sarkar; Kumbhakar, Dharmadas; Tiwari, Umesh; Bhatnagar, Randhir

    2013-08-01

    In this work we present a novel nanomaterial coating technique using evanescent wave (EW). The gradient force in the EW is used as an optical tweezer for tweezing and self-assembling nanoparticles on the source of EW. As a proof of the concept, we have used a laser coupled etched multimode optical fiber, which generates EW for the EW assisted coating. The section-wise etched multimode optical fiber is horizontally and superficially dipped into a silver/gold nanoparticles solution while the laser is switched on. The fiber is left until the solution recedes due to evaporation leaving the fiber in air. The coating time usually takes 40-50 min at room temperature. The scanning electron microscope image shows uniform and thin coating of self-assembled nanoparticles due to EW around the etched section. A coating thickness optical fiber probes and other plasmonic circuits.

  19. Clean Energy Solutions Center (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Reategui, S.

    2012-07-01

    The Clean Energy Ministerial launched the Clean Energy Solutions Center in April, 2011 for major economy countries, led by Australia and U.S. with other CEM partners. Partnership with UN-Energy is extending scope to support all developing countries: 1. Enhance resources on policies relating to energy access, small to medium enterprises (SMEs), and financing programs; 2. Offer expert policy assistance to all countries; 3. Expand peer to peer learning, training, and deployment and policy data for developing countries.

  20. Membrane assisted liquid-liquid extraction of cerium

    International Nuclear Information System (INIS)

    Soldenhoff, K.M.

    2000-02-01

    Membrane assisted liquid-liquid extraction of cerium was investigated, with emphasis placed on the study of the reaction chemistry and the kinetics of non-dispersive solvent extraction and stripping with microporous membranes. A bulk liquid membrane process was developed for the purification of cerium(IV) from sulfate solutions containing other rare earth elements. The cerium process was studied in both a flat sheet contained liquid membrane configuration and with hollow fibre contactors. Di-2-ethylhexyl phosphoric acid (DEHPA) was identified as a suitable extractant for cerium(IV) from sulfuric acid solution, with due consideration of factors such as extraction ability, resistance to degradation, solvent selectivity and potential for sulfate transfer into a strip solution. A detailed study of the extraction of cerium(IV) with DEHPA defined the extraction reaction chemistry. The Ce/DEHPA/sulfate system was also investigated with a flat sheet bulk liquid membrane configuration, using both sulfuric and hydrochloric acid as receiver solutions. These tests identified that hydrophobic membranes provide better mass transfer for extraction and hydrophilic membranes are better for stripping. The presence of an impurity, mono 2-ethylhexyl phosphoric acid (MEHPA), was found to have a dramatic accelerating effect on the rate of the chemical extraction reaction. This was attributed to its higher interfacial activity and population compared to DEHPA, and the fact that MEHPA was also found to be an active carrier for cerium(IV). The mass transfer rate of membrane assisted extraction and stripping of cerium, using hydrophobic and hydrophilic microporous membranes, respectively, was investigated using a modified Lewis-type cell. It was quantitatively demonstrated that the extraction process was mainly controlled by membrane diffusion and the stripping process was controlled by the chemical reaction rate, with membrane diffusion becoming important at low distribution coefficients

  1. Los Alamos neutral particle transport codes: New and enhanced capabilities

    International Nuclear Information System (INIS)

    Alcouffe, R.E.; Baker, R.S.; Brinkley, F.W.; Clark, B.A.; Koch, K.R.; Marr, D.R.

    1992-01-01

    We present new developments in Los Alamos discrete-ordinates transport codes and introduce THREEDANT, the latest in the series of Los Alamos discrete ordinates transport codes. THREEDANT solves the multigroup, neutral-particle transport equation in X-Y-Z and R-Θ-Z geometries. THREEDANT uses computationally efficient algorithms: Diffusion Synthetic Acceleration (DSA) is used to accelerate the convergence of transport iterations, the DSA solution is accelerated using the multigrid technique. THREEDANT runs on a wide range of computers, from scientific workstations to CRAY supercomputers. The algorithms are highly vectorized on CRAY computers. Recently, the THREEDANT transport algorithm was implemented on the massively parallel CM-2 computer, with performance that is comparable to a single-processor CRAY-YMP We present the results of THREEDANT analysis of test problems

  2. Evolutionary design assistants for architecture

    Directory of Open Access Journals (Sweden)

    N. Onur Sönmez

    2015-04-01

    existing literature and the proposals and applications of the thesis; secondly, proposals for descriptive and prescriptive models, mappings, summary illustrations, task structures, decomposition schemes, and integratory frameworks; and finally, experimental applications of these proposals. This tripartite progression allows an evaluation of each proposal both conceptually and practically; thereby, enabling a progressive improvement of the understanding regarding the research question, while producing concrete outputs on the way. Besides theoretical and interpretative examinations, the thesis investigates its subject through a set of practical and speculative proposals, which function as both research instruments and the outputs of the study. The first main output of the study is the “design_proxy” approach (d_p, which is an integrated approach for draft making design assistants. It is an outcome of both theoretical examinations and experimental applications, and proposes an integration of, (1 flexible and relaxed task definitions and representations (instead of strict formalisms, (2 intuitive interfaces that make use of usual design media, (3 evaluation of solution proposals through their similarity to given examples, and (4 a dynamic evolutionary approach for solution generation. The design_proxy approach may be useful for AD researchers that aim at developing practical design assistants, as has been examined and demonstrated with the two applications, i.e., design_proxy.graphics and design_proxy.layout. The second main output, the “Interleaved Evolutionary Algorithm” (IEA, or Interleaved EA is a novel evolutionary algorithm proposed and used as the underlying generative mechanism of design_proxybased design assistants. The Interleaved EA is a dynamic, adaptive, and multi-objective EA, in which one of the objectives leads the evolution until its fitness progression stagnates; in the sense that the settings and fitness values of this objective is used for most

  3. Review of advanced driver assistance systems (ADAS)

    Science.gov (United States)

    Ziebinski, Adam; Cupek, Rafal; Grzechca, Damian; Chruszczyk, Lukas

    2017-11-01

    New cars can be equipped with many advanced safety solutions. Airbags, seatbelts and all of the essential passive safety parts are standard equipment. Now cars are often equipped with new advanced active safety systems that can prevent accidents. The functions of the Advanced Driver Assistance Systems are still growing. A review of the most popular available technologies used in ADAS and descriptions of their application areas are discussed in this paper.

  4. Evaluation of intracranial arteriovenous malformations before and after embolization with dynamic MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Feng Xiaoyuan; Baleriaux, D.; Metens, T.

    2005-01-01

    Objective: To evaluate the clinical utility and accuracy of dynamic MR digital subtraction angiography (MR-DSA) in the detection of intracranial arteriovenous malformations before and after embolization. Methods: A prospective blinded comparison of MR-DSA, 3D contrast-enhanced T 1 -weighted MR angiography (3D-CEMRA), proton-weighted imaging and conventional digital subtraction angiography (DSA) were underwent in 22 consecutive AVMs patients before and after embolization. Two readers independently interpreted images and compared with DSA images. Results: There was complete agreement between MR-DSA and DSA for classification and size of nidus before and after embolization in all cases. MR-DSA showed the modified hemodynamic features (the time of nidus, early venous enhancement delayed after carotid arteries appearance) in 17 cases, and nidus size were reduced in 13 cases (including 4 complete embolized cases) after embolization, which were 100% consistence compared with DSA. MR-DSA failed to depict 1 intranidal aneurysm and missed 1 less dilated artery and draining vein after embolization respectively, which were demonstrated clearly by 3D-CEMRA confirmed with DSA. The relatively more or less hyperintensity could be seen on proton-weighted imaging in all cases after embolization than before. Conclusion: MR-DSA is a fast, efficient, and noninvasive technique to provide hemodynamic information relevant for AVMs before and after embolization. Proton imaging is sensitive in delineation of the embolized region, MR-DSA, 3D-CEMRA and proton-weighted imaging should be combined in the evaluation and follow-up AVMs after partial embolization. (authors)

  5. Toward the art of robotic-assisted vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Amir Molaei

    2017-01-01

    Full Text Available New technological progress in robotics has brought many beneficial clinical applications. Currently, computer integrated robotic surgery has gained clinical acceptance for several surgical procedures. Robotically assisted eye surgery is envisaged as a promising solution to overcome the shortcomings inherent to conventional surgical procedures as in vitreoretinal surgeries. Robotics by its high precision and fine mechanical control can improve dexterity, cancel tremor, and allow highly precise remote surgical capability, delicate vitreoretinal manipulation capabilities. Combined with magnified three-dimensional imaging of the surgical site, it can enhance surgical precision. Tele-manipulation can provide the ability for tele-surgery or haptic feedback of forces generated by the manipulation of intraocular tissues. It presents new solutions for some sight-threatening conditions such as retinal vein cannulation where, due to physiological limitations of the surgeon's hand, the procedure cannot be adequately performed. In this paper, we provide an overview of the research and advances in robotically assisted vitreoretinal eye surgery. Additionally the barriers to the integration of this method in the field of ocular surgery are summarized. Finally, we discuss the possible applications of the method in the area of vitreoretinal surgery.

  6. Maximizing Employment Outcomes through the Use of "Lower-Tech" Assistive Technology & Rehabilitation Engineering.

    Science.gov (United States)

    Grott, Ray

    2015-01-01

    For many people with disabilities, Assistive Technology tools and Rehabilitation Engineering principles are key to successful employment outcomes. At the same time, employers and service providers are often under the impression that accommodations and AT solutions require high-tech, complicated, and expensive technologies. This paper discusses how creative problem solving and a "keep it simple" mindset can result in very functional low-cost solutions.

  7. Digital subtraction angiography for breast diseases

    International Nuclear Information System (INIS)

    Okuyama, Nobuo; Okamoto, Yasushi; Kurita, Minoru; Nonaka, Naomichi; Ozawa, Yoshiyuki; Tsurumi, Kiyohiko

    1986-01-01

    We performed digital subtraction angiography (DSA) via arteries (IA-DSA) and veins (IV-DSA) on 42 patients with breast diseases to investigate its availability. The findings by DSA in cases with breast cancer included: tumor stains, hypervascularity and tortuosity, enlarged blood vessels, encasement and pooling. Metastatic lymph nodes and daughter nodules were also recognized by DSA. In benign tumors of the breast, a tumor stain was observed only in one case of fibroadenoma; otherwise no remarkable changes were noticed. The incidence of signs in cases with breast cancer using IA-DSA was 65 % for hypervascularity, 59 % for tumor stain, 41 % for vascular tortuosity and 41 % for enlargement of vessels. IV-DSA, on the contrary, revealed less incidences. However, tumor stain was seen frequently, and hypervascularity was seldom observed. The number of signs out of the abovementioned six appearing in each case was tabulated. With IA-DSA, there were 5 signs noted in 2 cases, but the majority had fewer: 4 cases in 4 cases and only 2 signs in 4 cases. There were no signs evident in 18 % of the cases. The incidence of the appearance of signs with IV-DSA was lower: there were no signs in 36 % of the cases. Therefore, the diagnostic accuracy of IA-DSA seemed to be fairly good in comparison with that of IV-DSA. The rate of appearance of abnormal signs was also examined, according to the size of the tumors. In IA-DSA, T 1 breast cancers revealed malignant signs in 80 % of the cases, in T 2 there were such signs 75 % and 100 % of the T 3 cases exhibited malignant signs, for an overall average of 82 %. In IV-DSA, T 1 showed 33 %, T 2 showed 70 %, and T 3 , 1 out of 1 case, showed malignant signs, 64 % altogether. It was the bigger the tumor, the larger the number of signs. The smallest breast cancer that exhibited abnormality in DSA was 1.0 x 0.7 cm in size. (J.P.N.)

  8. Mina: A Sensorimotor Robotic Orthosis for Mobility Assistance

    OpenAIRE

    Raj, Anil K.; Neuhaus, Peter D.; Moucheboeuf, Adrien M.; Noorden, Jerryll H.; Lecoutre, David V.

    2011-01-01

    While most mobility options for persons with paraplegia or paraparesis employ wheeled solutions, significant adverse health, psychological, and social consequences result from wheelchair confinement. Modern robotic exoskeleton devices for gait assistance and rehabilitation, however, can support legged locomotion systems for those with lower extremity weakness or paralysis. The Florida Institute for Human and Machine Cognition (IHMC) has developed the Mina, a prototype sensorimotor robotic ort...

  9. Environmentally-Assisted Cracking of Low-Alloy Reactor Pressure Vessel Steels under Boiling Water Reactor Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Seifert, H.P.; Ritter, S

    2002-02-01

    The present report summarizes the experimental work performed by PSI on the environmentally-assisted cracking (EAC) of low-alloy steels (LAS) in the frame of the RIKORR-project during the period from January 2000 to August 2001. Within this project, the EAC crack growth behaviour of different low-alloy reactor pressure vessel (RPV) steels, weld filler and weld heat-affected zone materials is investigated under simulated transient and steady-state BWR/NWC power operation conditions. The EAC crack growth behaviour of different low-alloy RPV steels was characterized by slow rising load (SRL) / low-frequency corrosion fatigue (LFCF) and constant load tests with pre-cracked fracture mechanics specimens in oxygenated high-temperature water at temperatures of either 288, 250, 200 or 150 C. These tests revealed the following important interim results: Under low-flow and highly oxidizing (ECP >= 100 mV SHE) conditions, the ASME XI 'wet' reference fatigue crack growth curve could be significantly exceeded by cyclic fatigue loading at low frequencies (<0.001 Hz), at high and low load-ratios R, and by ripple loading near to DKth fatigue thresholds. The BWR VIP 60 SCC disposition lines may be significantly or slightly exceeded (even in steels with a low sulphur content) in the case of small load fluctuations at high load ratios (ripple loading) or at intermediate temperatures (200 -250 C) in RPV materials, which show a distinct susceptibility to dynamic strain ageing (DSA). (author)

  10. INAA study of U sorption from technological solution by different microorganisms

    International Nuclear Information System (INIS)

    Mukhamedshina, N. M.; Mirsagatova, A. A.; Bekmukhamrdova, N. K.; Khamidova, M. Kh.; Rakhimova, M. S.

    2004-01-01

    Extraction of U from technological solution excludes a loss of valuable metal and pollution of the environment by heavy and radioactive element. For the purpose, nontraditional method of extraction using capacity of the microorganism sells to accumulate metal ions (cation) has been applied. Aim of this work is to study of U sorption from technological solutions by different microorganisms and to search more effective bio sorbents among microorganisms- actinomycetes, fungal culture (Acremonium, Aspergillus) by using INAA. INAA is more available and cheap method for us also it has high enough sensitivity and allows to avoid exposing the bacteria to radioactive metals. Atomic absorptive analyzer is more suitable for the determination of impurities in solutions, but it is expensive and not available for us. Actinomycetes were reproduced on starch-ammoniac agar medium: NaNO 3 - 1 g, actinomycetes MgSO 4 - 1 g, K 2 HPO 4 -1 g, starch -10 g, agar -20 g, distilled water - 1000 ml, pH = 6.8 - 7.0 on horizontal shaker (180 rpm) at temperature 28-30 degree for 1-3 days. Fungi were reproduced in liquid medium: NaNO 3 - 2 g, K 2 HPO 4 -1 g, KCl - 0.5 g, MgSO 4 - 0.5 g, FeSO 4 - 0.01 g, saccharose -20.0 g, tap water -1000 ml, pH = 7.0-7.2 on horizontal shaker (180 rpm) at temperature 28-30 degree for 1-3 days. After reproduction strains actinomycetes and fungi were separated by centrifuging (6000 rpm) and washed many times by distilled water. Strains of actinomycetes and fungi (1 g of each) were placed in 1 litre of the U technological solution (70.0 mg/l) and mixed on horizontal shaker (180 rpm). Interaction between strains and solution lasted 5, 10, 15, 30 and 60 min. After interaction the content of U not sorbed by strains (residual content) was measured from the over-sedimentary solution (decantate). 1 ml solution (decantate) was dropped on strip of ash free filter paper. The strips (samples) were dried, wrapped in the aluminum packets and placed in a container for

  11. Bridging Flows: Microfluidic End‐User Solutions

    DEFF Research Database (Denmark)

    Sabourin, David

    Microfluidic applications hold promise for many different end‐users both within and outside, and across many different research communities. Despite the benefits of microfluidic approaches, adoption and implementation thereof is often hindered by practical issues. Microfluidic components which......‐integrated interconnection and miniaturized peristaltic pump solutions were then combined into modular microfluidic systems. One system provides high interconnection numbers/density and allows many possible configurations. Additionally, and apart from many other accounts of modular microfluidic solutions, methods...... for control and actuation of microfluidic networks built from the modular components is described. Prototypes of the microfluidic system have begun to be distributed to external collaborators and researcher parties. These end‐users will assist in the validation of the approach and ultimately fulfil the key...

  12. VMCast: A VM-Assisted Stability Enhancing Solution for Tree-Based Overlay Multicast.

    Directory of Open Access Journals (Sweden)

    Weidong Gu

    Full Text Available Tree-based overlay multicast is an effective group communication method for media streaming applications. However, a group member's departure causes all of its descendants to be disconnected from the multicast tree for some time, which results in poor performance. The above problem is difficult to be addressed because overlay multicast tree is intrinsically instable. In this paper, we proposed a novel stability enhancing solution, VMCast, for tree-based overlay multicast. This solution uses two types of on-demand cloud virtual machines (VMs, i.e., multicast VMs (MVMs and compensation VMs (CVMs. MVMs are used to disseminate the multicast data, whereas CVMs are used to offer streaming compensation. The used VMs in the same cloud datacenter constitute a VM cluster. Each VM cluster is responsible for a service domain (VMSD, and each group member belongs to a specific VMSD. The data source delivers the multicast data to MVMs through a reliable path, and MVMs further disseminate the data to group members along domain overlay multicast trees. The above approach structurally improves the stability of the overlay multicast tree. We further utilized CVM-based streaming compensation to enhance the stability of the data distribution in the VMSDs. VMCast can be used as an extension to existing tree-based overlay multicast solutions, to provide better services for media streaming applications. We applied VMCast to two application instances (i.e., HMTP and HCcast. The results show that it can obviously enhance the stability of the data distribution.

  13. Digital subtraction angiography in cardiac diseases

    International Nuclear Information System (INIS)

    Choi, Deuk Lin; Kim, Ki Jeong

    1986-01-01

    DSA was done in 133 examinations of 128 patients during 2 years consist of 9 examination of IV DSA and 124 examination of selective cardiac DSA after cardiac catheterization. Open heart surgery was performed in 90 patients and 12 patients showed discrepancy between pre-and post operative diagnosis, showing a total 86.7% of diagnostic accuracy with DSA. We experienced the significant reduction in dose of contrast media, 30-40% of dose of conventional cardiac angiography. It is concluded that DSA is useful in the evaluation of septal defects, valvular disease and other congenital heart disease. DSA is an accurate simple and safe method in evaluating of cardiac diseases.

  14. A Novel Algorithm for Solving the Multidimensional Neutron Transport Equation on Massively Parallel Architectures

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Yousry

    2014-06-10

    We employ the Integral Transport Matrix Method (ITMM) as the kernel of new parallel solution methods for the discrete ordinates approximation of the within-group neutron transport equation. The ITMM abandons the repetitive mesh sweeps of the traditional source iterations (SI) scheme in favor of constructing stored operators that account for the direct coupling factors among all the cells' fluxes and between the cells' and boundary surfaces' fluxes. The main goals of this work are to develop the algorithms that construct these operators and employ them in the solution process, determine the most suitable way to parallelize the entire procedure, and evaluate the behavior and parallel performance of the developed methods with increasing number of processes, P. The fastest observed parallel solution method, Parallel Gauss-Seidel (PGS), was used in a weak scaling comparison with the PARTISN transport code, which uses the source iteration (SI) scheme parallelized with the Koch-baker-Alcouffe (KBA) method. Compared to the state-of-the-art SI-KBA with diffusion synthetic acceleration (DSA), this new method- even without acceleration/preconditioning-is completitive for optically thick problems as P is increased to the tens of thousands range. For the most optically thick cells tested, PGS reduced execution time by an approximate factor of three for problems with more than 130 million computational cells on P = 32,768. Moreover, the SI-DSA execution times's trend rises generally more steeply with increasing P than the PGS trend. Furthermore, the PGS method outperforms SI for the periodic heterogeneous layers (PHL) configuration problems. The PGS method outperforms SI and SI-DSA on as few as P = 16 for PHL problems and reduces execution time by a factor of ten or more for all problems considered with more than 2 million computational cells on P = 4.096.

  15. Balloon-Occluded Carbon Dioxide Gas Angiography for Internal Iliac Arteriography and Intervention.

    Science.gov (United States)

    Kishino, Mitsuhiro; Nakaminato, Shuichiro; Kitazume, Yoshio; Miyasaka, Naoyuki; Kudo, Toshifumi; Saida, Yukihisa; Tateishi, Ukihide

    2018-07-01

    The usefulness of carbon dioxide (CO 2 ) gas digital subtraction angiography (DSA) has been reported for patients with renal insufficiency and allergy to iodinated contrast agents. However, CO 2 gas cannot replace the iodinated contrast agent in all cases owing to some disadvantages. We describe balloon-occluded CO 2 DSA (B-CO 2 DSA) as an improved CO 2 DSA procedure for interventions in the internal iliac artery (IIA) region and compare the quality of images obtained using conventional CO 2 DSA and B-CO 2 DSA. B-CO 2 DSA-guided embolization was performed for one case of genital bleeding with an acute anaphylactic reaction to the iodinated contrast agent and for three cases of type II endoleaks after endovascular abdominal aortic aneurysm repair with renal dysfunction. A 9-mm occlusion balloon catheter was placed just after the orifice of the IIA. Then, 10-15 ml of CO 2 gas was injected manually via the catheter with and without balloon occlusion. The quality of sequential digital subtraction angiograms was analyzed based on a scoring criterion. In all four cases, image quality was improved with B-CO 2 DSA; the poor quality of images without balloon occlusion was because of reflux of the CO 2 gas. B-CO 2 DSA improves the image quality of CO 2 DSA in the IIA region and is useful for vascular intervention. Level IV.

  16. Multigrid methods for S/sub N/ problems

    International Nuclear Information System (INIS)

    Nowak, P.F.; Larsen, E.W.; Martin, W.R.

    1987-01-01

    It has long been known that the standard source iteration (SI) method for obtaining iterative solutions of S/sub N/ problems is very slowly converging in optically thick regions with low absorption. The rebalance and diffusion synthetic acceleration (DSA) methods are generalizations of SI that have been developed to accelerate convergence, but neither of these methods has been completely successful. In particular, the rebalance method tends to become unstable in problems where it is needed most (problems with high scattering ratios c = 1), while the DSA method, to be implemented in a stable fashion, requires the solution of a particular system of acceleration equations, and this has been done efficiently in two-dimensional geometries only for the diamond difference S/sub N/ equations. This paper discusses another extension of the SI method, namely, SI combined with the spatial multigrid algorithm (SIMG). This appears to be a viable way to accelerate many S/sub N/ problems in multidimensional geometries, provided the finest mesh consists of cells that are not optically thick

  17. ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.

    Science.gov (United States)

    Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu

    2015-02-01

    IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.

  18. Computer utilization for the solution of gas supply problems

    Energy Technology Data Exchange (ETDEWEB)

    Raleigh, J T; Brady, J R

    1968-01-01

    The computer programs in this paper have proven to be useful tools in the solution of gas supply problems. Some of the management type of applications are: (1) long range planning projects; (2) comparison of various proposed gas purchase contracts; (3) to assist with budget and operational planning; (4) to assist in making cost-of-servic and rate predictions; (5) to investigate the feasibility of processing plants at any point on the system; and (6) to assist dispatching in its daily operation for cost and quality control. Competition, not only from the gas industry, but also from other forms of energy, makes it imperative that quantitative and economic information with regard to that marketable resource be available under a variety of assumptions and alternatives. This information can best be made available in a timely manner by the use of the computer.

  19. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  20. Analyse sonore et multimodale dans le domaine de l'assistance à domicile

    OpenAIRE

    Vacher , Michel

    2011-01-01

    The average age of the population in industrialized countries is steadily increasing. Seniors living alone are more numerous, either because they prefer to live independently, or because of a lack of space in the specialized institutions. We must find solutions allowing them to continue to stay at home comfortably and safely. Smart housings can constitute one of these solutions. One of the biggest challenges in Ambient Assisted Living (AAL) is to develop smart homes that anticipate the health...

  1. Donor Specific Anti-HLA Antibodies with Antibody Mediated Rejection and Long-term Outcomes Following Heart Transplantation

    Science.gov (United States)

    Clerkin, Kevin J.; Farr, Maryjane A.; Restaino, Susan W.; Zorn, Emmanuel; Latif, Farhana; Vasilescu, Elena R.; Marboe, Charles C.; Colombo, Paolo C.; Mancini, Donna M.

    2017-01-01

    Introduction Donor specific anti-HLA antibodies (DSA) are common following heart transplantation and are associated with rejection, cardiac allograft vasculopathy (CAV), and mortality. Currently a non-invasive diagnostic test for pathologic AMR (pAMR) does not exist. Methods 221 consecutive adult patients underwent heart transplantation from January 1st, 2010 through August 31th, 2013 and followed through October 1st, 2015. The primary objective was to determine whether the presence of DSA could detect AMR at the time of pathologic diagnosis. Secondary analyses included the association of DSA (stratified by MHC Class and de-novo status) during AMR with new graft dysfunction, graft loss (mortality or retransplantation), and development of CAV. Results During the study period 69 individual patients (31.2%) had DSA (24% had de-novo DSA) and there were 74 episodes of pAMR in 38 unique patients. The sensitivity of DSA at any MFI to detect concurrent pAMR was only 54.3%. The presence of any DSA during pAMR increased the odds of graft dysfunction (OR 5.37, 95% CI 1.34–21.47, p=0.018), adjusting for age, gender, and timing of AMR. Circulating Class II DSA after transplantation increased the risk of future pAMR (HR 2.97, 95% CI 1.31–6.73, p=0.009). Patients who developed de-novo Class II DSA had a 151% increase in risk of graft loss (contingent on 30-day survival) compared with those who did not have DSA (95% CI 1.11–5.69, p=0.027). Conclusions DSA were inadequate to diagnose pAMR, but Class II DSA provided prognostic information regarding future pAMR, graft dysfunction with pAMR, and graft loss. PMID:27916323

  2. Donor-specific anti-HLA antibodies with antibody-mediated rejection and long-term outcomes following heart transplantation.

    Science.gov (United States)

    Clerkin, Kevin J; Farr, Maryjane A; Restaino, Susan W; Zorn, Emmanuel; Latif, Farhana; Vasilescu, Elena R; Marboe, Charles C; Colombo, Paolo C; Mancini, Donna M

    2017-05-01

    Donor-specific anti-HLA antibodies (DSA) are common after heart transplantation and are associated with rejection, cardiac allograft vasculopathy, and mortality. A noninvasive diagnostic test for pathologic antibody-mediated rejection (pAMR) does not exist. From January 1, 2010, through August 31, 2013, 221 consecutive adult patients underwent heart transplantation and were followed through October 1, 2015. The primary objective was to determine whether the presence of DSA could detect AMR at the time of pathologic diagnosis. Secondary analyses included association of DSA (stratified by major histocompatibility complex class and de novo status) during AMR with new graft dysfunction, graft loss (mortality or retransplantation), and development of cardiac allograft vasculopathy. During the study period, 69 patients (31.2%) had DSA (24% had de novo DSA), and there were 74 episodes of pAMR in 38 patients. Sensitivity of DSA at any mean fluorescence intensity to detect concurrent pAMR was only 54.3%. The presence of any DSA during pAMR increased the odds of graft dysfunction (odds ratio = 5.37; 95% confidence interval [CI], 1.34-21.47; p = 0.018), adjusting for age, sex, and timing of AMR. Circulating class II DSA after transplantation increased risk of future pAMR (hazard ratio = 2.97; 95% CI, 1.31-6.73; p = 0.009). Patients who developed de novo class II DSA had 151% increased risk of graft loss (contingent on 30-day survival) compared with patients who did not have DSA (95% CI, 1.11-5.69; p = 0.027). DSA were inadequate to diagnose pAMR. Class II DSA provided prognostic information regarding future pAMR, graft dysfunction with pAMR, and graft loss. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Portevin-Le Chatelier effect in an E911 creep resistant steel with 3%Co additives

    International Nuclear Information System (INIS)

    Kipelova, A; Kaibyshev, R; Skorobogatykh, V; Schenkova, I

    2010-01-01

    The effect of tempering temperature on mechanical properties of an E911+3%Co creep resistant steel was investigated. The mechanical tensile tests were carried out at temperatures from 298 to 1073 K and at strain rates varying from 2.1 x 10 -5 s -1 to 2.1 x 10 -1 s -1 . The Portevin-Le Chatelier (PLC) effect was found in the temperature range of 473 to 623 K. Various attributes of dynamic strain aging (DSA) like serrated flow with an acoustic emission were observed. With increasing temperature the ultimate tensile strength (UTS) and the yield strength (YS) increased while the ductility decreased. The dependences of the critical plastic strain on strain rate and temperature exhibited 'inverse' behavior that was associated with concentrated solid solution in the DSA regime.

  4. Application of preconditioned GMRES to the numerical solution of the neutron transport equation

    International Nuclear Information System (INIS)

    Patton, B.W.; Holloway, J.P.

    2002-01-01

    The generalized minimal residual (GMRES) method with right preconditioning is examined as an alternative to both standard and accelerated transport sweeps for the iterative solution of the diamond differenced discrete ordinates neutron transport equation. Incomplete factorization (ILU) type preconditioners are used to determine their effectiveness in accelerating GMRES for this application. ILU(τ), which requires the specification of a dropping criteria τ, proves to be a good choice for the types of problems examined in this paper. The combination of ILU(τ) and GMRES is compared with both DSA and unaccelerated transport sweeps for several model problems. It is found that the computational workload of the ILU(τ)-GMRES combination scales nonlinearly with the number of energy groups and quadrature order, making this technique most effective for problems with a small number of groups and discrete ordinates. However, the cost of preconditioner construction can be amortized over several calculations with different source and/or boundary values. Preconditioners built upon standard transport sweep algorithms are also evaluated as to their effectiveness in accelerating the convergence of GMRES. These preconditioners show better scaling with such problem parameters as the scattering ratio, the number of discrete ordinates, and the number of spatial meshes. These sweeps based preconditioners can also be cast in a matrix free form that greatly reduces storage requirements

  5. Assistive Solutions in Practice: Experiences from AAL Pilot Regions in Austria.

    Science.gov (United States)

    Ates, Nesrin; Aumayr, Georg; Drobics, Mario; Förster, Kristina Maria; Frauenberger, Christopher; Garschall, Markus; Kofler, Manfred; Krainer, Daniela; Kropf, Johannes; Majcen, Kurt; Oberzaucher, Johannes; Piazolo, Felix; Rzepka, Angelika; Sauskojus, Julia; Schneider, Cornelia; Stainer-Hochgatterer, Andreas; Sturm, Nadine; Waibel, Uli; Willner, Viktoria

    2017-01-01

    Since 2012 six AAL pilot regions were launched in Austria. The main goal of these pilot regions is to evaluate the impact of AAL technologies in daily use considering the entire value chain. Additionally, go-to market strategies for assistive technologies based on an involvement of all relevant stakeholders are developed. Within this paper an overview of the specific objectives, approaches and the status of all Austrian AAL pilot regions is given. Taking into account the different experiences of the different pilot regions, specific challenges in establishing, implementing and sustaining pilot region projects are discussed and lessons-learned are presented. Results show that a careful planning of all project phases taking into account available resources is crucial for the successful implementation of an AAL pilot region. In particular, this applies to all activities related to the active involvement of end-users.

  6. Three-dimensional image reconstruction using rotational digital subtraction technique: the initial experience of the clinical application

    International Nuclear Information System (INIS)

    Ouyang Zhongnan; Tang Jun; He Jianjun; Lu Xiaohe; Xun Yanping

    2002-01-01

    Objective: To evaluate the benefit of three-dimensional (3D) reconstruction images with rotational digital subtraction technique for the clinical applications. Methods: Conventional two-dimensional digital substraction angiography (2D DSA) was obtained on A-P and lateral view. Three-dimensional digital subtraction angiography (3D DSA) images were obtained by reconstruction of a rotational acquisition on a C-arm (LCV +, GE Medical Systems) spinning at 40 degrees per second. 53 cases of cerebral angiographies were performed (32 men and 21 women; the age ranged from 19 to 72 years, mean 46.3 years). Results: In this series of 53 cases of cerebral angiographies, 5 cases of arteriovenous malformation were all correctly diagnosed by 3D DSA and 2D DSA. Seven cases were misdiagnosed as intracranial aneurysms at conventional 2D DSA but confirmed to be kinking of the vessel by 3D DSA. 41 cases were confirmed to be intracranial aneurysms. Of the 41 cases, 5 cases were diagnosed as normal at 2D DSA but confirmed to be intracranial aneurysms at 3D DSA. The total consistency rate of 3D DSA and 2D DSA for the diagnosis of intracranial aneurysm is 77.4% (41/53). The consistent test shows that there was consistency between the two modalities (chi-square test, χ 2 = 5.267, P < 0.05). 29 cases were treated with endovascular coil embolization. Among them only 3 cases of the aneurysm's neck could be best visualized by 2D DSA but 29 cases by 3D DSA. Conclusion: 3D reconstruction images with rotational digital subtraction technique is a useful tool to study the vascular diseases using less contrast agent and a lower radiation dose and shortening the examination process. It is replenishment for conventional 2D DSA. This technique enables better diagnosis for intracranial vascular lesion and visualization of complex vascular relationships and structures. It is valuable for surgical planning and interventional procedure

  7. Assisted Reproduction Techniques (Art): The State of the Art in Nigeria

    African Journals Online (AJOL)

    Background: Infertility has become a social stigma in our environment because of the erroneous belief that a childless marriage is a failed marriage. This has placed a lot of marriages under pressure. Therefore any solution to infertility is a welcome relief. This is where Assisted Reproduction Techniques (ART) belongs.

  8. Porous carbon spheres via microwave-assisted synthesis for capacitive deionization

    International Nuclear Information System (INIS)

    Liu, Yong; Pan, Likun; Chen, Taiqiang; Xu, Xingtao; Lu, Ting; Sun, Zhuo; Chua, Daniel H.C.

    2015-01-01

    Highlights: • Porous carbon spheres were fabricated through a fast microwave-assisted approach. • The capacitive deionization performance of Porous carbon spheres was studied. • Porous carbon spheres exhibit a high NaCl removal with good regeneration ability. - Abstract: Porous carbon spheres (PCSs) were fabricated through a fast microwave-assisted approach using sucrose as the precursor in a microwave system and subsequent thermal treatment at 600, 800 and 1000 °C. The morphology, structure and electrochemical performance of the PCSs were characterized by scanning electron microscopy, Raman spectroscopy, nitrogen adsorption-desorption, cyclic voltammetry and electrochemical impedance spectroscopy. Their electrosorption performance in NaCl solution was studied and compared with activated carbon, carbon nanotubes, reduced graphene and carbon aerogels. The results show that due to their high specific surface area and low charge transfer resistance, PCSs treated at 1000 °C exhibit high electrosorption capacity of 5.81 m g g −1 when the initial solution concentration is 500 mg l −1 , which is higher than those of other carbon materials

  9. The Principal Leadership Problems Confronting the Chief of a Military Assistance Advisory Group and Some Solutions for Selected Problems

    Science.gov (United States)

    1964-05-20

    comparative standards of sanitation had made her afraid to take a chance on the famed cuisine of European restaurants . Paris, Rome and Madrid, to...Assistance / b Institute, Washington, D. C.) Sands, William B. 11 An Advisor ’ s Talk To t he Chinese . 11 (In the files of the Mili tary Assistance

  10. Hepatic Arterial Configuration in Relation to the Segmental Anatomy of the Liver; Observations on MDCT and DSA Relevant to Radioembolization Treatment

    International Nuclear Information System (INIS)

    Hoven, Andor F. van den; Leeuwen, Maarten S. van; Lam, Marnix G. E. H.; Bosch, Maurice A. A. J. van den

    2015-01-01

    PurposeCurrent anatomical classifications do not include all variants relevant for radioembolization (RE). The purpose of this study was to assess the individual hepatic arterial configuration and segmental vascularization pattern and to develop an individualized RE treatment strategy based on an extended classification.MethodsThe hepatic vascular anatomy was assessed on MDCT and DSA in patients who received a workup for RE between February 2009 and November 2012. Reconstructed MDCT studies were assessed to determine the hepatic arterial configuration (origin of every hepatic arterial branch, branching pattern and anatomical course) and the hepatic segmental vascularization territory of all branches. Aberrant hepatic arteries were defined as hepatic arterial branches that did not originate from the celiac axis/CHA/PHA. Early branching patterns were defined as hepatic arterial branches originating from the celiac axis/CHA.ResultsThe hepatic arterial configuration and segmental vascularization pattern could be assessed in 110 of 133 patients. In 59 patients (54 %), no aberrant hepatic arteries or early branching was observed. Fourteen patients without aberrant hepatic arteries (13 %) had an early branching pattern. In the 37 patients (34 %) with aberrant hepatic arteries, five also had an early branching pattern. Sixteen different hepatic arterial segmental vascularization patterns were identified and described, differing by the presence of aberrant hepatic arteries, their respective vascular territory, and origin of the artery vascularizing segment four.ConclusionsThe hepatic arterial configuration and segmental vascularization pattern show marked individual variability beyond well-known classifications of anatomical variants. We developed an individualized RE treatment strategy based on an extended anatomical classification

  11. Decontamination of electronic waste-polluted soil by ultrasound-assisted soil washing.

    Science.gov (United States)

    Chen, Fu; Yang, Baodan; Ma, Jing; Qu, Junfeng; Liu, Gangjun

    2016-10-01

    Laboratorial scale experiments were performed to evaluate the efficacy of a washing process using the combination of methyl-β-cyclodextrin (MCD) and tea saponin (TS) for simultaneous desorption of hydrophobic organic contaminants (HOCs) and heavy metals from an electronic waste (e-waste) site. Ultrasonically aided mixing of the field contaminated soil with a combination of MCD and TS solutions simultaneously mobilizes most of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), and the analyte metal (Pb, Cu, and Ni) burdens. It is found that 15 g/L MCD and 10 g/L TS is an efficient reagent combination reconciling extraction performance and reagent costs. Under these conditions, the removal efficiencies of HOCs and heavy metals are 93.5 and 91.2 %, respectively, after 2 cycles of 60-min ultrasound-assisted washing cycles. By contrast, 86.3 % of HOCs and 88.4 % of metals are removed from the soil in the absence of ultrasound after 3 cycles of 120-min washing. The ultrasound-assisted soil washing could generate high removal efficiency and decrease the operating time significantly. Finally, the feasibility of regenerating and reusing the spent washing solution in extracting pollutants from the soil is also demonstrated. By application of this integrated technology, it is possible to recycle the washing solution for a purpose to reduce the consumption of surfactant solutions. Collectively, it has provided an effective and economic treatment of e-waste-polluted soil.

  12. Microwave assisted air drying of osmotically treated pineapple with variable power programmes

    CSIR Research Space (South Africa)

    Botha, GE

    2012-01-01

    Full Text Available Variable power programmes for microwave assisted air drying of pineapple were studied. The pineapple pieces were pre-treated by osmotic dehydration in a 55º Brix sucrose solution at 40ºC for 90 minutes. Variable power output programmes were designed...

  13. Telecare and Social Link Solution for Ambient Assisted Living Using a Robot Companion with Visiophony

    Science.gov (United States)

    Varène, Thibaut; Hillereau, Paul; Simonnet, Thierry

    An increasing number of people are in need of help at home (elderly, isolated and/or disabled persons; people with mild cognitive impairment). Several solutions can be considered to maintain a social link while providing tele-care to these people. Many proposals suggest the use of a robot acting as a companion. In this paper we will look at an environment constrained solution, its drawbacks (such as latency) and its advantages (flexibility, integration…). A key design choice is to control the robot using a unified Voice over Internet Protocol (VoIP) solution, while addressing bandwidth limitations, providing good communication quality and reducing transmission latency

  14. Fast and versatile microwave-assisted intramolecular Heck reaction in peptide macrocyclization using microwave energy.

    Science.gov (United States)

    Byk, Gerardo; Cohen-Ohana, Mirit; Raichman, Daniel

    2006-01-01

    We have revisited the intramolecular Heck reaction and investigated the microwave-assisted macrocyclization on preformed peptides using a model series of ring-varying peptides acryloyl-Gly-[Gly](n)-Phe(4-I)NHR; n = 0-4. The method was applied to both solution and solid supported cyclizations. We demonstrate that the intramolecular Heck reaction can be performed in peptides both in solution and solid support using a modified domestic microwave within 1 to 30 minutes in DMF under reflux with moderate yields ranging from 15 to 25% for a scale between 2-45 mg of linear precursors. The approach was applied to the synthesis of a constrained biologically relevant peptidomimetic bearing an Arg-Gly-Asp (RGD) sequence. These results make the microwave-assisted Heck reaction an attractive renovated approach for peptidomimetics. Copyright 2006 Wiley Periodicals, Inc.

  15. Highly Efficient 2D/3D Hybrid Perovskite Solar Cells via Low-Pressure Vapor-Assisted Solution Process.

    Science.gov (United States)

    Li, Ming-Hsien; Yeh, Hung-Hsiang; Chiang, Yu-Hsien; Jeng, U-Ser; Su, Chun-Jen; Shiu, Hung-Wei; Hsu, Yao-Jane; Kosugi, Nobuhiro; Ohigashi, Takuji; Chen, Yu-An; Shen, Po-Shen; Chen, Peter; Guo, Tzung-Fang

    2018-06-08

    The fabrication of multidimensional organometallic halide perovskite via a low-pressure vapor-assisted solution process is demonstrated for the first time. Phenyl ethyl-ammonium iodide (PEAI)-doped lead iodide (PbI 2 ) is first spin-coated onto the substrate and subsequently reacts with methyl-ammonium iodide (MAI) vapor in a low-pressure heating oven. The doping ratio of PEAI in MAI-vapor-treated perovskite has significant impact on the crystalline structure, surface morphology, grain size, UV-vis absorption and photoluminescence spectra, and the resultant device performance. Multiple photoluminescence spectra are observed in the perovskite film starting with high PEAI/PbI 2 ratio, which suggests the coexistence of low-dimensional perovskite (PEA 2 MA n -1 Pb n I 3 n +1 ) with various values of n after vapor reaction. The dimensionality of the as-fabricated perovskite film reveals an evolution from 2D, hybrid 2D/3D to 3D structure when the doping level of PEAI/PbI 2 ratio varies from 2 to 0. Scanning electron microscopy images and Kelvin probe force microscopy mapping show that the PEAI-containing perovskite grain is presumably formed around the MAPbI 3 perovskite grain to benefit MAPbI 3 grain growth. The device employing perovskite with PEAI/PbI 2 = 0.05 achieves a champion power conversion efficiency of 19.10% with an open-circuit voltage of 1.08 V, a current density of 21.91 mA cm -2 , and a remarkable fill factor of 80.36%. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Two Novel Methods and Multi-Mode Periodic Solutions for the Fermi-Pasta-Ulam Model

    Science.gov (United States)

    Arioli, Gianni; Koch, Hans; Terracini, Susanna

    2005-04-01

    We introduce two novel methods for studying periodic solutions of the FPU β-model, both numerically and rigorously. One is a variational approach, based on the dual formulation of the problem, and the other involves computer-assisted proofs. These methods are used e.g. to construct a new type of solutions, whose energy is spread among several modes, associated with closely spaced resonances.

  17. Development of autonomic management solutions for the military application domain

    NARCIS (Netherlands)

    Werkman, E.; Schoonhoven, B. van; Jonge, M. de; Matthijssen, E.

    2010-01-01

    The Dutch Ministry of Defence is faced with ICT management problems, due to the increased use of complex ICT systems in the battle field. Solutions in the industry, such as remote assistance, cannot be applied in a domain with unreliable, low-bandwidth connections. In a case study performed at the

  18. Microwave-assisted Facile and Ultrafast Growth of ZnO Nanostructures and Proposition of Alternative Microwave-assisted Methods to Address Growth Stoppage

    Science.gov (United States)

    Rana, Abu Ul Hassan Sarwar; Kang, Mingi; Kim, Hyun-Seok

    2016-04-01

    The time constraint in the growth of ZnO nanostructures when using a hydrothermal method is of paramount importance in contemporary research, where a long fabrication time rots the very essence of the research on ZnO nanostructures. In this study, we present the facile and ultrafast growth of ZnO nanostructures in a domestic microwave oven within a pressurized environment in just a few minutes. This method is preferred for the conventional solution-based method because of the ultrafast supersaturation of zinc salts and the fabrication of high-quality nanostructures. The study of the effect of seed layer density, growth time, and the solution’s molar concentration on the morphology, alignment, density, and aspect ratio of ZnO nanorods (ZNRs) is explored. It is found in a microwave-assisted direct growth method that ~5 mins is the optimum time beyond which homogeneous nucleation supersedes heterogeneous nucleation, which results in the growth stoppage of ZNRs. To deal with this issue, we propound different methods such as microwave-assisted solution-replacement, preheating, and PEI-based growth methods, where growth stoppage is addressed and ZNRs with a high aspect ratio can be grown. Furthermore, high-quality ZnO nanoflowers and ZnO nanowalls are fabricated via ammonium hydroxide treatment in a very short time.

  19. An evaluation of microwave-assisted fusion and microwave-assisted acid digestion methods for determining elemental impurities in carbon nanostructures using inductively coupled plasma optical emission spectrometry

    KAUST Repository

    Patole, Shashikant P.

    2015-10-21

    It is common for as-prepared carbon nanotube (CNT) and graphene samples to contain remnants of the transition metals used to catalyze their growth; contamination may also leave other trace elemental impurities in the samples. Although a full quantification of impurities in as-prepared samples of carbon nanostructures is difficult, particularly when trace elements are intercalated or encapsulated within a protective layer of graphitic carbon, reliable information is essential for reasons such as quantifying the adulteration of physico-chemical properties of the materials and for evaluating environmental issues. Here, we introduce a microwave-based fusion method to degrade single- and double-walled CNTs and graphene nanoplatelets into a fusion flux thereby thoroughly leaching all metallic impurities. Subsequent dissolution of the fusion product in diluted hydrochloric and nitric acid allowed us to identify their trace elemental impurities using inductively coupled plasma optical emission spectrometry. Comparisons of the results from the proposed microwave-assisted fusion method against those of a more classical microwave-assisted acid digestion approach suggest complementarity between the two that ultimately could lead to a more reliable and less costly determination of trace elemental impurities in carbon nanostructured materials. Graphical abstract A method for the complete digestion of carbon nanostructures has been demonstrated. Photographs (on the left side) show zirconium crucibles containing SWCNTs with flux of Na2CO3 and K2CO3, before and after microwave fusion; (on the right side) the appearance of the final solutions containing dissolved samples, from microwave-assisted fusion and microwave-assisted acid digestion. These solutions were used for determining the trace elemental impurities by ICP‒OES.

  20. Generative Computer Assisted Instruction: An Application of Artificial Intelligence to CAI.

    Science.gov (United States)

    Koffman, Elliot B.

    Frame-oriented computer-assisted instruction (CAI) systems dominate the field, but these mechanized programed texts utilize the computational power of the computer to a minimal degree and are difficult to modify. Newer, generative CAI systems which are supplied with a knowledge of subject matter can generate their own problems and solutions, can…

  1. Kinetics and Thermodynamics of Ultrasound-Assisted Depolymerization of κ-Carrageenan

    Directory of Open Access Journals (Sweden)

    Ratnawati Ratnawati

    2016-03-01

    Full Text Available The ultrasound-assisted depolymerization of κ-carrageenan has been studied at various temperatures and times. The κ-carrageenan with initial molecular weight of 545 kDa was dispersed in water to form a 5 g/L solution, which was then depolymerized in an ultrasound device at various temperatures and times. The viscosity of the solution was measured using Brookfield viscometer, which was then used to find the number-average molecular weight by Mark-Houwink equation. To obtain the kinetics of κ-carrageenan depolymerization, the number-average molecular weight data was treated using midpoint-chain scission kinetics model. The pre-exponential factor and activation energies for the reaction are 2.683×10-7 mol g-1 min-1 and 6.43 kJ mol-1, respectively. The limiting molecular weight varies from 160 kDa to 240 kDa, and it is linearly correlated to temperature. The results are compared to the result of thermal depolymerization by calculating the half life. It is revealed that ultrasound assisted depolymerization of κ-carrageenan is faster than thermal depolymerization at temperatures below 72.2°C. Compared to thermal depolymerization, the ultrasound-assisted process has lower values of Ea, ΔG‡, ΔH‡, and ΔS‡, which can be attributed to the ultrasonically induced breakage of non-covalent bonds in κ-carrageenan molecules. Copyright © 2016 BCREC GROUP. All rights reserved Received: 10th November 2015; Revised: 18th January 2016; Accepted: 19th January 2016 How to Cite: Ratnawati, R., Prasetyaningrum, A., Wardhani, D.H. (2016. Kinetics and Thermodynamics of Ultrasound-Assisted Depolymerization of κ-Carrageenan. Bulletin of Chemical Reaction Engineering & Catalysis, 11(1: 48-58. (doi:10.9767/bcrec.11.1.415.48-58 Permalink/DOI: http://dx.doi.org/10.9767/bcrec.11.1.415.48-58

  2. Concordance of Time-of-Flight MRA and Digital Subtraction Angiography in Adult Primary Central Nervous System Vasculitis.

    Science.gov (United States)

    de Boysson, H; Boulouis, G; Parienti, J-J; Touzé, E; Zuber, M; Arquizan, C; Dequatre, N; Detante, O; Bienvenu, B; Aouba, A; Guillevin, L; Pagnoux, C; Naggara, O

    2017-10-01

    3D-TOF-MRA and DSA are 2 available tools to demonstrate neurovascular involvement in primary central nervous system vasculitis. We aimed to compare the diagnostic concordance of vessel imaging using 3D-TOF-MRA and DSA in patients with primary central nervous system vasculitis. We retrospectively identified all patients included in the French primary central nervous system vasculitis cohort of 85 patients who underwent, at baseline, both intracranial 3D-TOF-MRA and DSA in an interval of no more than 2 weeks and before treatment initiation. Two neuroradiologists independently reviewed all 3D-TOF-MRA and DSA imaging. Brain vasculature was divided into 25 arterial segments. Concordance between 3D-TOF-MRA and DSA for the identification of arterial stenosis was assessed by the Cohen κ Index. Thirty-one patients met the inclusion criteria, including 20 imaged with a 1.5T MR unit and 11 with a 3T MR unit. Among the 25 patients (81%) with abnormal DSA findings, 24 demonstrated abnormal 3D-TOF-MRA findings, whereas all 6 remaining patients with normal DSA findings had normal 3D-TOF-MRA findings. In the per-segment analysis, concordance between 1.5T 3D-TOF-MRA and DSA was 0.82 (95% CI, 0.75-0.93), and between 3T 3D-TOF-MRA and DSA, it was 0.87 (95% CI, 0.78-0.91). 3D-TOF-MRA shows a high concordance with DSA in diagnostic performance when analyzing brain vasculature in patients with primary central nervous system vasculitis. In patients with negative 3T 3D-TOF-MRA findings, the added diagnostic value of DSA is limited. © 2017 by American Journal of Neuroradiology.

  3. Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry of friction modifier additives analyzed directly from base oil solutions.

    Science.gov (United States)

    Widder, Lukas; Brennerb, Josef; Huttera, Herbert

    2014-01-01

    To develop new products and to apply measures of quality control quick and simple accessibility of additive composition in automo- tive lubrication is important. The aim of this study was to investigate the possibility of analyzing organic friction modifier additives by means of atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry [AP-MALDI-MS] from lubricant solu- tions without the use of additional separation techniques. Analyses of selected friction modifier ethoxylated tallow amines and oleic acid amide were compared using two ionization methods, positive-ion electrospray ionization (ESI) and AP-MALDI, using a LTQ Orbitrap mass spectrometer. Pure additives were characterized from solvent solutions, as well as from synthetic and mineral base oil mixtures. Detected ions of pure additive samples consisted mainly of [M + H]+, but also alkaLi metal adducts [M + Na]+ and [M + K]+ could be seen. Characterizations of blends of both friction modifiers from the base oil mixtures were carried out as well and showed significant inten- sities for several additive peaks. Thus, this work shows a method to directly analyze friction modifier additives used in the automotive industry from an oil blend via the use of AP-MALDI without any further separation steps. The method presented will further simplify the acquisition of data on lubricant composition and additives. Furthermore, it allows the perspective of analyzing additive reaction products directly from formulated oil blends.

  4. The clinical and genomic significance of donor-specific antibody-positive/C4d-negative and donor-specific antibody-negative/C4d-negative transplant glomerulopathy.

    Science.gov (United States)

    Hayde, Nicole; Bao, Yi; Pullman, James; Ye, Bin; Calder, R Brent; Chung, Monica; Schwartz, Daniel; Lubetzky, Michelle; Ajaimy, Maria; de Boccardo, Graciela; Akalin, Enver

    2013-12-01

    This study investigated the mechanisms involved in development of donor-specific antibody (DSA) and/or C4d-negative transplant glomerulopathy (TGP) by allograft gene expression profiles using microarrays. This cohort study was conducted in kidney transplant recipients. Patients were eligible for inclusion if they required a clinically indicated biopsy at any time point after their transplant. They were then classified according to their histopathology findings and DSA and C4d results. Eighteen chronic antibody-mediated rejection (CAMR), 14 DSA+/C4d- TGP, 25 DSA-/C4d- TGP, and 47 nonspecific interstitial fibrosis/tubular atrophy (IFTA) biopsy specimens were identified. In a subset of patients from the study population, biopsy specimens in each group and normal transplant kidney specimens were analyzed with Affymetrix Human Gene 1.0 ST Arrays. The mean sum score of glomerulitis and peritubular capillaritis increased from 0.28±0.78 in IFTA specimens to 0.75±0.85 in DSA-/C4d- TGP specimens, 1.71±1.49 in DSA+/C4d-/TGP specimens, and 2.11±1.74 in CAMR specimens (PTGP specimens (14.3%), and DSA-/C4d- TGP specimens (16%) (P=0.01). With use of microarrays, comparison of the gene expression profiles of DSA-/C4d- TGP specimens with glomerulitis + peritubular capillaritis scores > 0 to normal and IFTA biopsy specimens revealed higher expression of quantitative cytotoxic T cell-associated transcripts (QCAT). However, both CAMR and DSA+/C4d- TGP specimens had higher expression of not only QCAT but also IFN-γ and rejection-induced, constitutive macrophage-associated, natural killer cell-associated, and DSA-selective transcripts. Endothelial cell-associated transcript expression was upregulated only in CAMR biopsy specimens. These results suggested that DSA+/C4d- TGP biopsy specimens may be classified as CAMR. In contrast, DSA-/C4d- TGP specimens showed increased cytotoxic T cell-associated transcripts, suggesting T cell activation as a mechanism of injury.

  5. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples

    OpenAIRE

    Tseng, C. M.; Garraud, H.; Amouroux, D.; Donard, O. F. X.; de Diego, A.

    1998-01-01

    This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO3 solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Met...

  6. Synthesis of (U,Zr)C solid solutions under exothermic conditions

    International Nuclear Information System (INIS)

    Wang, L.L.; Moore, H.G.; Gladson, J.W.

    1993-01-01

    The reactions of forming (U,Zr)C solid solutions from their elemental components or similarly less stable reactants such as UC 2 are strongly exothermic due to the high stability of these solid solutions. A simple approach of utilizing this heat of formation energy to assist the solid solution reaction process is to intimately mix the less stable reactant powders and then pressed them into a compact. The compact is then heated to the ignition temperature of the reaction. The feasibility of this reaction method to synthesize (U,Zr)C solid solutions has been demonstrated in this study. The preliminary results also show that both the initial composition and the heating rate have a significant effect on the nature of the reaction process. As expected the degree of powder mixing was also found to affect the completeness of the reaction

  7. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  8. MIGRATION – EFFECTS AND SOLUTIONS

    Directory of Open Access Journals (Sweden)

    Raluca Cruceru

    2012-12-01

    Full Text Available There are three main flows that influence workforce performance—worker migration, the dissemination of knowledge, and overseas development assistance. For the present paper we decided to deal with the analyses of these three, yet mainly migration. We considered it to be one of the most important phenomenon existent on the market at this hour and with the highest negative impact on the economic and social situation. We presented a case study regarding the situation of migration in Romania and the main candidates to Romanian intelligence imports, the main issues and possible solutions to the problems encountered.

  9. Spectrum Utilisation and Management in Cognitive Radio Networks

    DEFF Research Database (Denmark)

    Patil, Kishor P.

    have confirmed this by showing that the considerable amount of radio spectrum is underutilized. Dynamic Spectrum Access (DSA) and the spectrum refarming are the two viable solutions for the problem of spectrum scarcity. In DSA, unlicensed user opportunistically uses the vacant licensed spectrum...... of licensed spectrum provides efficient use of spectrum. Spectrum refarming means the recovery of spectrum from its existing users for the purpose of re-assignment, either for new uses, or for the introduction of new spectrally efficient technologies. Spectrum refarming is a spectrum management tool that can......In recent years, the demand for radio spectrum for wireless communication is growing due to increase in number of users and popularity of data and multimedia services. This has been observed in the recent auctions completed word wide for the vestige of radio spectrum. The radio spectrum has been...

  10. Inhibiting Effect of Additives on Pressure Solution of Calcite

    Science.gov (United States)

    Traskine, V.; Skvortsova, Z.; Badun, G.; Chernysheva, M.; Simonov, Ya.; Gazizullin, I.

    2018-05-01

    The task of protection of cultural heritage requires a better understanding of combined effects of mechanical and chemical factors involved in environmental deterioration of monuments. The present paper deals with extending some known physicochemical methods proposed for inhibiting the decay of unstressed materials to their study during water-assisted deformation. The tests have been carried out on natural limestone samples and calcite powders in CaCO3 saturated aqueous solutions under static loads causing measurable pressure solution creep. In the solutions containing 1-hydroxyethylidene-1,1-diphosphonic acid, nitrilotriacetic acid, or ethylenediaminetetraacetic acid, the creep rate decreases considerably with increasing concentration of additives. The extent of creep deceleration has been found to be proportional to the independently estimated calcite surface area occupied by adsorbed species. This fact enables us to discriminate the adsorption-induced effect from other variables controlling the pressure solution rate and may be used in screening of compounds able to minimize the environmental impact on marble and limestone objects undergoing mechanical stresses.

  11. System and method for laser assisted sample transfer to solution for chemical analysis

    Science.gov (United States)

    Van Berkel, Gary J; Kertesz, Vilmos

    2014-01-28

    A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

  12. Preparation of magnetic Ni@graphene nanocomposites and efficient removal organic dye under assistance of ultrasound

    International Nuclear Information System (INIS)

    Zhao, Chuang; Guo, Jianhui; Yang, Qing; Tong, Lei; Zhang, Jingwei; Zhang, Jiwei; Gong, Chunhong; Zhou, Jingfang; Zhang, Zhijun

    2015-01-01

    Graphical abstract: Reduced graphene oxide/Ni microspheres, being prepared under ultrasound conditions, exhibit a better removal efficiency to decolorize RhB with ultrasonic-assisted decolorization process. - Highlights: • One-step synthesis of Ni@graphene microspheres under ultrasound conditions. • During the ultrasonic process, graphene oxide was reduced and Ni nanoparticles were formed and anchored on graphene sheets. • The products exhibit excellent performance for fast and efficient removal of dye contaminants. • The nanocomposites can be easily separated from solution by a magnet. - Abstract: In this article, we report a facile one-step synthesis of Ni@graphene nanocomposite microspheres (NGs) in hydrazine hydrate solution under ultrasound conditions. During the ultrasonic process, graphene oxide (GO) was reduced effectively under mild conditions and Ni nanoparticles were simultaneously formed and anchored on graphene sheets, which act as spacers to keep the neighboring sheets separated. The target products exhibit excellent performance for fast and efficient removal of dye contaminants, rhodamine B (RhB) in aqueous solution, under assistance of ultrasound. Finally, the nanocomposites can be easily separated from solution by a magnet. Furthermore, higher content of graphene can be produced under sonication, which facilitates faster and more efficient removal of organic contaminates in the solution. The nanocomposites were also characterized by scanning electron microscopy, Raman spectroscopy, Fourier transformed infrared spectroscopy, X-ray photoelectron spectroscopy, X-ray powder diffraction and thermogravimetric analysis.

  13. Preparation of magnetic Ni@graphene nanocomposites and efficient removal organic dye under assistance of ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Chuang; Guo, Jianhui; Yang, Qing; Tong, Lei [Key Laboratory of Ministry of Education for Special Functional Materials, Henan University, Kaifeng 475004 (China); Zhang, Jingwei, E-mail: jwzhang@henu.edu.cn [Key Laboratory of Ministry of Education for Special Functional Materials, Henan University, Kaifeng 475004 (China); Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA 5095 (Australia); Zhang, Jiwei [Key Laboratory of Ministry of Education for Special Functional Materials, Henan University, Kaifeng 475004 (China); Gong, Chunhong [College of Chemistry and Chemical Engineering, Henan University, Kaifeng 475004 (China); Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA 5095 (Australia); Zhou, Jingfang, E-mail: jingfang.zhou@unisa.edu.au [Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA 5095 (Australia); Zhang, Zhijun [Key Laboratory of Ministry of Education for Special Functional Materials, Henan University, Kaifeng 475004 (China)

    2015-12-01

    Graphical abstract: Reduced graphene oxide/Ni microspheres, being prepared under ultrasound conditions, exhibit a better removal efficiency to decolorize RhB with ultrasonic-assisted decolorization process. - Highlights: • One-step synthesis of Ni@graphene microspheres under ultrasound conditions. • During the ultrasonic process, graphene oxide was reduced and Ni nanoparticles were formed and anchored on graphene sheets. • The products exhibit excellent performance for fast and efficient removal of dye contaminants. • The nanocomposites can be easily separated from solution by a magnet. - Abstract: In this article, we report a facile one-step synthesis of Ni@graphene nanocomposite microspheres (NGs) in hydrazine hydrate solution under ultrasound conditions. During the ultrasonic process, graphene oxide (GO) was reduced effectively under mild conditions and Ni nanoparticles were simultaneously formed and anchored on graphene sheets, which act as spacers to keep the neighboring sheets separated. The target products exhibit excellent performance for fast and efficient removal of dye contaminants, rhodamine B (RhB) in aqueous solution, under assistance of ultrasound. Finally, the nanocomposites can be easily separated from solution by a magnet. Furthermore, higher content of graphene can be produced under sonication, which facilitates faster and more efficient removal of organic contaminates in the solution. The nanocomposites were also characterized by scanning electron microscopy, Raman spectroscopy, Fourier transformed infrared spectroscopy, X-ray photoelectron spectroscopy, X-ray powder diffraction and thermogravimetric analysis.

  14. Intravenous digital subtraction angiography and helical computed tomography in evaluation of living renal donors

    International Nuclear Information System (INIS)

    Watarai, Yoshihiko; Usuki, Tomoaki; Takeuchi, Ichiro; Nonomura, Katsuya; Koyanagi, Tomohiko; Kubo, Kozo; Hirano, Tetsuo; Togashi, Masaki; Ohashi, Nobuo

    2001-01-01

    The present study was carried out to evaluate the accuracy of helical computed tomography (CT) and intravenous digital subtraction angiography (IV-DSA) on anatomical assessment of renal vasculature for living renal donors. Forty-two healthy potential renal donors were prospectively evaluated and 35 subsequently underwent donor nephrectomy after helical CT and IV-DSA evaluation. The vascular and non-vascular findings were compared between the findings on helical CT, IV-DSA and surgery. Ten prehilar branches and five accessory renal arteries were found at nephrectomy. Overall, operative findings agreed with the findings by IV-DSA in 89% and by helical CT in 83%. In delineating accessory arteries, IV-DSA had a sensitivity of 60% and specificity of 97%, whereas helical CT had a sensitivity of 40% and specificity of 100%. In delineating prehilar branches, IV-DSA had a sensitivity of 90% and specificity of 100%, whereas helical CT had a sensitivity of 70% and specificity of 100%. Accessory arteries and prehilar branches that were not detected by helical CT or IV-DSA, were less than 2 mm in diameter and did not require vascular reconstruction. Renal veins were delineated in 63% by IV-DSA, whereas they were clearly imaged by helical CT in all cases, including a case with a circumaortic renal vein. Non-vascular findings were obtained in 64% by helical CT, including two renal tumors. None of these findings were obtained by IV-DSA. Helical CT and IV-DSA provide comparably sufficient information on renal artery vasculature. However, helical CT provides significantly more information on venous and non-vascular findings as a single-imaging modality. (author)

  15. Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, Tobias; Hauer, Michael; Doerfler, Arnd [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Banckwitz, Rosemarie; Koehler, Christoph [Siemens AG, Healthcare Sector, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc, Hoffman Estates, IL (United States); University of Wisconsin, Department of Biomedical Engineering and School of Medicine and Public Health, Madison, WI (United States)

    2014-06-15

    Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols. Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer. (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv. The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. (orig.)

  16. Effective dose to patient measurements in flat-detector and multislice computed tomography: a comparison of applications in neuroradiology

    International Nuclear Information System (INIS)

    Struffert, Tobias; Hauer, Michael; Doerfler, Arnd; Banckwitz, Rosemarie; Koehler, Christoph; Royalty, Kevin

    2014-01-01

    Flat-detector CT (FD-CT) is used for a variety of applications. Additionally, 3D rotational angiography (3D DSA) is used to supplement digital subtraction angiography (DSA) studies. The aim was to measure and compare the dose of (1) standard DSA and 3D DSA and (2) analogous FD-CT and multislice CT (MSCT) protocols. Using an anthropomorphic phantom, the effective dose to patients (according to ICRP 103) was measured on an MSCT and a flat-detector angiographic system using standard protocols as recommended by the manufacturer. (1) Evaluation of DSA and 3D DSA angiography protocols: ap.-lat. Standard/low-dose series 1/0.8 mSv, enlarged oblique projection 0.3 mSv, 3D DSA 0.9 mSv (limited coverage length 0.3 mSv). (2) Comparison of FD-CT and MSCT: brain parenchyma imaging 2.9 /1.4 mSv, perfusion imaging 2.3/4.2 mSv, temporal bone 0.2 /0.2 mSv, angiography 2.9/3.3 mSv, limited to the head using collimation 0.5/0.5 mSv. The effective dose for an FD-CT application depends on the application used. Using collimation for FD-CT applications, the dose may be reduced considerably. Due to the low dose of 3D DSA, we recommend using this technique to reduce the number of DSA series needed to identify working projections. (orig.)

  17. Ultrasonic-assisted synthesis of monodisperse single-crystalline silver nanoplates and gold nanorings.

    Science.gov (United States)

    Jiang, Li-Ping; Xu, Shu; Zhu, Jian-Min; Zhang, Jian-Rong; Zhu, Jun-Jie; Chen, Hong-Yuan

    2004-09-20

    A simple sonochemical route was developed for the crystal growth of uniform silver nanoplates and ringlike gold nanocrystals in a N,N-dimethylformamide solution. The platelike structures were generated from the selective growth on different crystal planes in the presence of poly(vinylpyrrolidone) and the ultrasonic-assisted Ostwald ripening processes. The silver nanoplates in solution served as the templates for the synthesis of ringlike gold crystals via a displacement reaction. Both the silver nanoplates and gold nanorings were highly oriented single crystals with (111) planes as the basal planes. Copyright 2004 American Chemical Society

  18. Donor-specific antibodies require preactivated immune system to harm renal transplant.

    Science.gov (United States)

    Süsal, Caner; Döhler, Bernd; Ruhenstroth, Andrea; Morath, Christian; Slavcev, Antonij; Fehr, Thomas; Wagner, Eric; Krüger, Bernd; Rees, Margaret; Balen, Sanja; Živčić-Ćosić, Stela; Norman, Douglas J; Kuypers, Dirk; Emonds, Marie-Paule; Pisarski, Przemyslaw; Bösmüller, Claudia; Weimer, Rolf; Mytilineos, Joannis; Scherer, Sabine; Tran, Thuong H; Gombos, Petra; Schemmer, Peter; Zeier, Martin; Opelz, Gerhard

    2016-07-01

    It is an unresolved issue why some kidney transplant recipients with pretransplant donor-specific HLA antibodies (DSA) show a high transplant failure rate, whereas in other patients DSA do not harm the graft. We investigated whether help from preactivated T-cells might be necessary for DSA to exert a deleterious effect. The impact of pretransplant DSA and immune activation marker soluble CD30 (sCD30) on 3-year graft survival was analyzed in 385 presensitized kidney transplant recipients. A deleterious influence of pretransplant DSA on graft survival was evident only in patients who were positive for the immune activation marker sCD30. In the absence of sCD30 positivity, 3-year graft survival was virtually identical in patients with or without DSA (83.1±3.9% and 84.3±2.8%, P=0.81). A strikingly lower 3-year graft survival rate of 62.1±6.4% was observed in patients who were both sCD30 and DSA positive (HR 2.92, PsCD30 negative. Pretransplant DSA have a significantly deleterious impact on graft survival only in the presence of high pretransplant levels of the activation marker sCD30. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    Science.gov (United States)

    Shibuya, Makiko; Hiraoki, Toshifumi; Kimura, Kunie; Fukushima, Kazuaki; Suzuki, Kuniaki

    2012-12-01

    We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and τ values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  20. Mina: A Sensorimotor Robotic Orthosis for Mobility Assistance

    Directory of Open Access Journals (Sweden)

    Anil K. Raj

    2011-01-01

    Full Text Available While most mobility options for persons with paraplegia or paraparesis employ wheeled solutions, significant adverse health, psychological, and social consequences result from wheelchair confinement. Modern robotic exoskeleton devices for gait assistance and rehabilitation, however, can support legged locomotion systems for those with lower extremity weakness or paralysis. The Florida Institute for Human and Machine Cognition (IHMC has developed the Mina, a prototype sensorimotor robotic orthosis for mobility assistance that provides mobility capability for paraplegic and paraparetic users. This paper describes the initial concept, design goals, and methods of this wearable overground robotic mobility device, which uses compliant actuation to power the hip and knee joints. Paralyzed users can balance and walk using the device over level terrain with the assistance of forearm crutches employing a quadrupedal gait. We have initiated sensory substitution feedback mechanisms to augment user sensory perception of his or her lower extremities. Using this sensory feedback, we hypothesize that users will ambulate with a more natural, upright gait and will be able to directly control the gait parameters and respond to perturbations. This may allow bipedal (with minimal support gait in future prototypes.

  1. Effets néfastes sur la stabilité des solutions polyacrylamides utilisées dans la récupération assistée du pétrole Harmful Effects of Formaldehyde on the Stability of Polyacrylamide Solutions Used in Enhanced Oil Recovery

    Directory of Open Access Journals (Sweden)

    Catherin G.

    2006-11-01

    Full Text Available L'étude de la dégradation oxydante des polyacrylamides (PAA et HPAA en solution aqueuse nous a permis de trouver que du formaldéhyde est produit par l'oxydation de l'acrylamide résiduel. Du formaldéhyde est aussi produit par l'oxydation du méthanol résiduel quand ce non-solvant a été utilisé pour purifier les PAA et HPAA par précipitation de leurs solutions aqueuses. Ce formaldéhyde est responsable de la formation de dérivés insolubles nuisibles pour les propriétés rhéologiques utiles des solutions. Ce résultat rejoint ceux d'études antérieures où un effet comparable a été observé après addition de formaldéhyde aux solutions de PAA et HPAA. Mais l'examen de la littérature relative à la chimie du formaldéhyde montre que les réactions d'oxydation et d'addition qui ont été suggérées pour rendre compte de cet effet sont inadéquates dans le milieu considéré. Le schéma que nous proposons explique mieux les phénomènes observés. Nous avons aussi montré que l'oxydo-réduction du formaldéhyde est responsable de la formation de radicaux libres sur les polyacrylamides. II était alors possible de conclure, sans avoir recours à d'autres expériences, que le formaldéhyde ne doit pas être utilisé dans la récupération assistée du pétrole pour protéger les solutions des polyacrylamides contre la biodégradation. In a study of the oxidation of aqueous solutions of the polyacrylamides PAA and HPAA, we have found that formaldehyde is an oxidation product both of acrylamide residual in the commercial polymers and of the methanol residual in polymers purified by methanol precipitation from aqueous solutions. The presence of formaldehyde in turn causes the production of insoluble derivatives which spoil the rheological properties of polymer solutions. This result reinforces those of previous studies where a similar effect was observed after formaldehyde was added to solutions of PAA and HPAA. Examination of the

  2. Intravenous digital angiography for the detection of renovascular hypertension

    International Nuclear Information System (INIS)

    Dunnick, N.R.; Svetkey, L.; Braun, S.D.; Cohan, R.H.; Newman, G.E.; Himmelstein, S.I.; Klotman, P.E.

    1987-01-01

    In order to assess the accuracy of intravenous digital subtraction angiography (IV-DSA), the authors prospectively studied all patients referred for suspected renovascular hypertension with IV-DSA and conventional angiography. The IV-DSA study demonstrated renal artery stenosis in 25 patients. A significant main renal artery lesion was confirmed in 21 of these patients while four patients had either normal renal arteries or insignificant changes. The IV-DSA examination was considered negative for renal artery stenosis in 50 patients. This was confirmed in 49 patients, but one patient had a branch renal artery stenosis. The sensitivity of IV-DSA was 96% while the specificity was 93%. The negative predictive value was 98% and the positive predictive value 84%. IV-DSA provides good anatomic definition of the main renal arteries and is sufficiently sensitive to be used as a screening test for renovascular hypertension

  3. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    Science.gov (United States)

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  4. Fault-tolerance of Cluster Management in (MANETs) by assistant and mobile agents

    International Nuclear Information System (INIS)

    Hamad, H.

    2007-01-01

    Most researches today trend to clustering in ad hoc networks as a solution to the management problem in flat ad hoc networks. Clustering aims to choose suitable nodes to lead the network i.e., the cluster heads. When a cluster head fails, reclustering is needed. However, this will be costly due to the characteristics of the ad hoc networks such as mobility and exhaustion. In this research we developed a fault tolerance mechanism to avoid re-clustering and other drawbacks that result from loosing the Cluster Head (CH). A Mobile Agent (MA) will be responsible of carrying out the jobs of the CH i.e., the CH will host the MA which will be the real manager of the cluster. Furthermore, the closest node to the CH will be chosen as an assistant and the MA will update the assistant. Each of the CH and the assistant will have Remote Objects (RO) to communicate with each other. The main jobs of the assistant are to temporarily replace the CH when fails; then it will choose the next CH based on clustering algorithm. Simulation results show an enhancement of the performance of using an assistant, MA and RO. (author)

  5. The synthesis of Cu/Fe/Fe3O4 catalyst through the aqueous solution ball milling method assisted by high-frequency electromagnetic field

    Science.gov (United States)

    Yingzhe, Zhang; Yuxing, He; Qingdong, Qin; Fuchun, Wang; Wankun, Wang; Yongmei, Luo

    2018-06-01

    In this paper, nano-magnetic Cu/Fe/Fe3O4 catalyst was prepared by a new aqueous solution ball milling method assisted by high-frequency electromagnetic field at room temperature. The products were characterized by means of X-ray diffraction (XRD), high-resolution transmission electron microscope (HRTEM), selected area electron diffraction (SAED), and vibrating sample magnetometer (VSM). Microwave induced catalytic degradation of methylene blue (MB) was carried out in the presence of Cu/Fe/Fe3O4. The concentration of methylene blue was determined by UV-Vis spectrophotometry. The solid catalyst showed high catalytic activity of degrade MB and considerable saturation magnetization, lower remanence and coercivity. It indicate that the catalyst can be effectively separated for reuse by simply applying an external magnetic field and it can greatly promote their potential industrial application to eliminate organic pollutants from waste-water. Finally, we found that it is the non-thermal effect of microwave that activated the catalytic activity of Cu/Fe/Fe3O4 to degrade MB.

  6. International assistance. Licensing assistance project

    International Nuclear Information System (INIS)

    Aleev, A.

    1999-01-01

    Description of licensing assistance project for VATESI is presented. In licensing of unit No.1 of INPP VATESI is supported by many western countries. Experts from regulatory bodies or scientific organizations of those countries assist VATESI staff in reviewing documentation presented by INPP. Among bilateral cooperation support is provided by European Commission through Phare programme

  7. Fe(III)-loaded collagen fiber as a heterogeneous catalyst for the photo-assisted decomposition of Malachite Green

    International Nuclear Information System (INIS)

    Liu Xiaohu; Tang Rui; He Qiang; Liao Xuepin; Shi Bi

    2010-01-01

    A heterogeneous catalyst for Fenton reaction was prepared by immobilizing Fe(III) onto collagen fiber and its catalytic activity for the photo-assisted decomposition of Malachite Green (MG) was investigated. The results indicated that this Fe(III)-immobilized collagen fiber (Fe-CF) can effectively catalyse the decoloration and decomposition/mineralization of MG in aqueous solution. Catalysed by Fe-CF, MG solution was completely decolorized in 30 min, while 55.0% of TOC was removed from the dye solution within 120 min in the presence of H 2 O 2 and UVA irradiation (365 nm, 10 W). Fe-CF was recycled for seven times with certain activity loss (32.6% in decoloration, 18.5% in TOC removal), and its catalytic activity can be easily recovered by re-immobilization of Fe(III). Therefore, Fe-CF could act as an efficient and cost-effective catalyst for the photo-assisted decomposition of MG, and shows potential applications in practice.

  8. Comparison of Corneal Riboflavin Gradients Using Dextran and HPMC Solutions.

    Science.gov (United States)

    Ehmke, Tobias; Seiler, Theo G; Fischinger, Isaak; Ripken, Tammo; Heisterkamp, Alexander; Frueh, Beatrice E

    2016-12-01

    To determine the riboflavin concentration gradient in the anterior corneal stroma when using hydroxypropyl methylcellulose (HPMC) or dextran as the carrier agent. Four different groups of porcine corneas (5 each) were compared regarding the riboflavin concentration in the anterior stroma. Prior to all experiments, stable hydration conditions were established for the corresponding solution. The dextran groups were treated with 0.1% riboflavin in 20% dextran for 10 and 30 minutes and the HPMC groups with 0.1% riboflavin in 1.1% HPMC for 10 and 30 minutes. After imbibition, nonlinear microscopy and consecutive image analysis were used to determine two-photon fluorescence intensities. To determine the riboflavin concentration, corneas were saturated and measured a second time by two-photon microscopy. With this measurement, a proper correction for absorption and scattering could be performed. Ultraviolet-A (UVA) transmission was measured after the application time for each group. Riboflavin concentration decreased with increasing depth and increased with longer application times in all groups. Comparing the dextran for 30 minutes and HPMC for 10 minutes groups, a significantly higher stromal riboflavin concentration was found within the most anterior 70 µm in the dextran group for 30 minutes, whereas deeper than 260 µm HPMC-assisted imbibition for 10 minutes yielded higher concentrations. In dextran-treated corneas, values obtained from pachymetry were substantially reduced, whereas HPMC-assisted imbibition led to a decent swelling. UVA transmission values were higher in dextran-assisted imbibition than in HPMC-assisted imbibition. Stromal riboflavin gradients are similar when applied in dextran for 30 minutes and HPMC for 10 minutes. When using HPMC solutions, a shallower cross-linked volume is expected due to a higher corneal hydration. [J Refract Surg. 2016;32(12):798-802.]. Copyright 2016, SLACK Incorporated.

  9. Canine assisted reading

    OpenAIRE

    Sever, Jerneja

    2016-01-01

    The diploma thesis presents various aspects of animals included in animal-assisted interventions. In theoretical part, I introduced different possible ways of animal-assisted interventions: animal-assisted therapy, animal-assisted activities and animal-assisted education. Animals became common visitors in educational settings all over the world. I presented positive influences on various aspects of human life, as well limitations when animal-assisted interventions are not possible to perform ...

  10. EDTA-assisted Pb phytoextraction.

    Science.gov (United States)

    Saifullah; Meers, E; Qadir, M; de Caritat, P; Tack, F M G; Du Laing, G; Zia, M H

    2009-03-01

    Pb is one of the most widespread and metal pollutants in soil. It is generally concentrated in surface layers with only a minor portion of the total metal found in soil solution. Phytoextraction has been proposed as an inexpensive, sustainable, in situ plant-based technology that makes use of natural hyperaccumulators as well as high biomass producing crops to help rehabilitate soils contaminated with heavy metals without destructive effects on soil properties. The success of phytoextraction is determined by the amount of biomass, concentration of heavy metals in plant, and bioavailable fraction of heavy metals in the rooting medium. In general, metal hyperaccumulators are low biomass, slow growing plant species that are highly metal specific. For some metals such as Pb, there are no hyperaccumulator plant species known to date. Although high biomass-yielding non-hyperaccumulator plants lack an inherent ability to accumulate unusual concentrations of Pb, soil application of chelating agents such as EDTA has been proposed to enhance the metal concentration in above-ground harvestable plant parts through enhancing the metal solubility and translocation from roots to shoots. Leaching of metals due to enhanced mobility during EDTA-assisted phytoextraction has been demonstrated as one of the potential hazards associated with this technology. Due to environmental persistence of EDTA in combination with its strong chelating abilities, the scientific community is moving away from the use of EDTA in phytoextraction and is turning to less aggressive alternative strategies such as the use of organic acids or more degradable APCAs (aminopolycarboxylic acids). We have therefore arrived at a point in phytoremediation research history in which we need to distance ourselves from EDTA as a proposed soil amendment within the context of phytoextraction. However, valuable lessons are to be learned from over a decade of EDTA-assisted phytoremediation research when considering the

  11. Nuclear inelastic scattering of synchrotron radiation on solutions of 57Fe complexes

    International Nuclear Information System (INIS)

    Vanko, Gy.; Vertes, A.; Bottyan, L.; Nagy, D.L.; Szilagyi, E.

    2000-01-01

    Nuclear inelastic resonant scattering of synchrotron radiation was applied to the study solutions of 57 Fe complexes. In order to reveal different inelastic contributions solutions of two different 57 Fe complexes of different molecular dimensions with solvents of substantially different viscosities were studied. We argue that the only former experiment available in the literature overestimates the role of the diffusivity in affecting the spectrum. The first direct observation of an intramolecular vibrational transition assisting the nuclear resonance absorption in a liquid is reported. (author)

  12. The effects of general anesthetics on ESR spectra of spin labels in phosphatidylcholine vesicles containing purified Na,K-ATPase or microsomal protein

    Energy Technology Data Exchange (ETDEWEB)

    Shibuya, Makiko, E-mail: shibu@den.hokudai.ac.jp [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Hiraoki, Toshifumi [Division of Applied Physics, Graduate School of Engineering, Hokkaido University (Japan); Kimura, Kunie; Fukushima, Kazuaki [Department of Dental Anesthesiology, Graduate School of Dental Medicine, Hokkaido University (Japan); Suzuki, Kuniaki [Department of Molecular Cell Pharmacology, Graduate School of Dental Medicine, Hokkaido University (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer We studied the effects of general anesthetics on liposome using ESR spectra. Black-Right-Pointing-Pointer Two spin labels, 5-DSA and 16-DSA, were located in different position in liposome. Black-Right-Pointing-Pointer Anesthetics did not change the environment around the spin labels in the liposome. Black-Right-Pointing-Pointer Anesthetics remained on the surface of the lipid bilayer of liposome. Black-Right-Pointing-Pointer Proteins in the liposome did not change the effects of anesthetics on liposome. - Abstract: We investigated the effects of general anesthetics on liposome containing spin labels, 5-doxyl stearic acid (5-DSA) and 16-doxyl stearic acid (16-DSA), and purified Na,K-ATPase or membrane protein of microsome using an electron spin resonance (ESR) spectroscopy. The spectra of 16-DSA in liposomes with both proteins showed three sharp signals compared with 5-DSA. The difference in the order parameter S value of 5-DSA and 16-DSA suggested that the nitroxide radical location of 5-DSA and 16-DSA were different in the membrane bilayer. The results were almost the same as those obtained in liposomes without proteins. The addition of sevoflurane, isoflurane, halothane, ether, ethanol and propofol increased the intensity of the signals, but the clinical concentrations of anesthetics did not significantly alter the S and {tau} values, which are indices of the fluidity of the membrane. These results suggest that anesthetics remain on the surface of the lipid bilayer and do not act on both the inside hydrophobic area and the relatively hydrophilic area near the surface. These results and others also suggest that the existence of Na,K-ATPase and microsomal proteins did not affect the environment around the spin labels in the liposome and the effects of anesthetics on liposome as a model membrane.

  13. MRA versus digital subtraction angiography in acute subarachnoid haemorrhage: a blinded multireader study of prospectively recruited patients

    International Nuclear Information System (INIS)

    Jaeger, H.R.; Hausmann, O.; Moseley, I.F.; Taylor, W.J.; Mansmann, U.; Partzsch, U.

    2000-01-01

    We performed a blinded multireader study comparing MR angiography (MRA) with digital subtraction angiography (DSA) in 34 prospectively recruited patients who presented with acute subarachnoid haemorrhage (SAH). Two observers independently reviewed the MRA and DSA studies some months after clinical presentation. Presence of an aneurysm was rated on a 4-point confidence scale. Cases in which the initial interpretation of the observers varied were jointly reviewed to reach a consensus opinion. DSA was deliberately chosen not to represent the reference standard and the clinical course and surgical findings were used to explain significant differences between the consensus readings of MRA and DSA. Diagnostic confidence and interobserver agreement were, overall, higher on DSA than on MRA studies (κ DSA = 0.64 versus κ MRA = 0.52 with 95 % CI for Δ = κ DSA -κ MRA [-0.06, 0.31]). With both methods, discrepancies between observers were due to aneurysms overlooked rather than false-positive readings by one observer. Diagnostic accuracy therefore improved when the readings of the two observers were combined, particularly for MRA. Intermethod agreement was only fair and similar for both readers (κ reader 1 = 0.37 versus κ reader 2 = 0.32 with 95 % CI for Δ = κ reader 1 -κ reader 2 [-0.02, 0.11]). Both interobserver and intermethod agreements improved when the data were analysed on a per-study (positive or negative study) rather than on a per-aneurysm basis. Differences in the consensus reading were due to five aneurysms (four single and one multiple) detected only with MRA and five (two single and three multiple) detected only with DSA. MRA and DSA should be regarded as complementary in the investigation of patients with acute SAH. DSA can no longer be regarded as the reference standard. (orig.)

  14. Growth of thick La2Zr2O7 buffer layers for coated conductors by polymer-assisted chemical solution deposition

    International Nuclear Information System (INIS)

    Zhang, Xin; Zhao, Yong; Xia, Yudong; Guo, Chunsheng; Cheng, C.H.; Zhang, Yong; Zhang, Han

    2015-01-01

    Highlights: • We develops a low-cost and high-efficient technology of fabricating LZO buffer layers. • Sufficient thickness LZO buffer layers have been obtained on NiW (2 0 0) alloy substrate. • Highly biaxially textured YBCO thin film has been deposited on LZO/NiW. - Abstract: La 2 Zr 2 O 7 (LZO) epitaxial films have been deposited on LaAlO 3 (LAO) (1 0 0) single-crystal surface and bi-axially textured NiW (2 0 0) alloy substrate by polymer-assisted chemical solution deposition, and afterwards studied with XRD, SEM and AFM approaches. Highly in-plane and out-of-plane oriented, dense, smooth, crack free and with a sufficient thickness (>240 nm) LZO buffer layers have been obtained on LAO (1 0 0) single-crystal surface; The films deposited on NiW (2 0 0) alloy substrate are also found with high degree in-plane and out-of-plane texturing, good density with pin-hole-free, micro-crack-free nature and a thickness of 300 nm. Highly epitaxial 500 nm thick YBa 2 Cu 3 O 7−x (YBCO) thin film exhibits the self-field critical current density (Jc) reached 1.3 MA/cm 2 at 77 K .These results demonstrate the LZO epi-films obtained with current techniques have potential to be a buffer layer for REBCO coated conductors

  15. Assisted Living

    Science.gov (United States)

    ... it, too. Back to top What is the Cost for Assisted Living? Although assisted living costs less than nursing home ... Primarily, older persons or their families pay the cost of assisted living. Some health and long-term care insurance policies ...

  16. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    International Nuclear Information System (INIS)

    U-King-Im, J.M.; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H.

    2004-01-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging

  17. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, J.M. E-mail: jhg21@cam.ac.uk; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H

    2004-04-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.

  18. Acute subarachnoid haemorrhage: Is a negative CT angiogram enough?

    International Nuclear Information System (INIS)

    MacKinnon, A.D.; Clifton, A.G.; Rich, P.M.

    2013-01-01

    Aim: To determine the negative predictive value of 16 channel multisection computed tomography angiography (CTA) for detecting aneurysms in spontaneous subarachnoid haemorrhage (SAH), using digital subtraction angiography (DSA) as the reference standard. Materials and methods: The prospectively collected cerebral angiogram database of Department of Neuroradiology, Atkinson Morley Regional Neuroscience Centre was used to identify 200 consecutive patients who had undergone DSA for SAH. Of these, 176 had undergone CTA prior to DSA. Clinical details and radiology reports were correlated and images of positive investigations reviewed. Results: DSA showed one or more cerebral aneurysms in 105 (60%) patients. These were correctly reported on CTA in 100. CTA was reported negative for aneurysms in 74 patients. Of these five were false negative and had aneurysms detected on DSA. In the CTA/DSA negative group, 11 (16%) patients had classical perimesencephalic clinical syndrome and blood distribution. There were two false positives at CTA. For ruptured cerebral aneurysms, CTA had 95.2% sensitivity, 97.2% specificity, 98.1% positive predictive value, and 93.2% negative predictive value. Conclusion: The sensitivity and negative predictive value of CTA for ruptured aneurysms remains imperfect. Continued use of DSA is recommended in most patients with a negative CTA after acute SAH. Confirmation of a negative CTA result with DSA may not be routinely required in patients with perimesencephalic syndrome

  19. Capitalizing Resolving Power of Density Gradient Ultracentrifugation by Freezing and Precisely Slicing Centrifuged Solution: Enabling Identification of Complex Proteins from Mitochondria by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Haiqing Yu

    2016-01-01

    Full Text Available Density gradient centrifugation is widely utilized for various high purity sample preparations, and density gradient ultracentrifugation (DGU is often used for more resolution-demanding purification of organelles and protein complexes. Accurately locating different isopycnic layers and precisely extracting solutions from these layers play a critical role in achieving high-resolution DGU separations. In this technique note, we develop a DGU procedure by freezing the solution rapidly (but gently after centrifugation to fix the resolved layers and by slicing the frozen solution to fractionate the sample. Because the thickness of each slice can be controlled to be as thin as 10 micrometers, we retain virtually all the resolution produced by DGU. To demonstrate the effectiveness of this method, we fractionate complex V from HeLa mitochondria using a conventional technique and this freezing-slicing (F-S method. The comparison indicates that our F-S method can reduce complex V layer thicknesses by ~40%. After fractionation, we analyze complex V proteins directly on a matrix assisted laser desorption/ionization, time-of-flight mass spectrometer. Twelve out of fifteen subunits of complex V are positively identified. Our method provides a practical protocol to identify proteins from complexes, which is useful to investigate biomolecular complexes and pathways in various conditions and cell types.

  20. Detection of unruptured familial intracranial aneurysms by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Berg, H.W.M. ter; Regional Hospital Almelo; Overtoom, T.M.D.; Ludwig, J.W.; Bijlsma, J.B.; Tulleken, C.A.F.; Willemse, J.

    1987-01-01

    The authors discuss the detection of intracranial aneurysms (IA) by means of intravenous digital angiography (ivDSA) in (a)symptomatic first degree relatives of families in which more than two or more individuals have IA. ivDSA is an almost noninvasive and low-risk diagnostic procedure. Screening, by means of ivDSA, of two affected families is described. In family I which includes 7 members with proven IA, ivDSA has been carried out in 36 asymptomatic individuals: in one, a 6x15 mm aneurysm was found at the left posterior communicating artery (PCoA). In family II, including one member with a proven IA and another with a subarachnoidal hemorrhage, ivDSA has been carried out in 4 members: one aneurysm with a diameter of 6 mm was found at the left PCoA. Conventional cerebral angiography (CCA) confirmed both IA's. Neurosurgical treatment followed. The advantages and disadvantages of ivDSA vs. CCA as elective screening procedure in such cases are discussed. Screening of asymptomatic first degree relatives of cases with familial IA by means of ivDSA is strongly advocated. (orig.)

  1. Transport synthetic acceleration scheme for multi-dimensional neutron transport problems

    Energy Technology Data Exchange (ETDEWEB)

    Modak, R S; Kumar, Vinod; Menon, S V.G. [Theoretical Physics Div., Bhabha Atomic Research Centre, Mumbai (India); Gupta, Anurag [Reactor Physics Design Div., Bhabha Atomic Research Centre, Mumbai (India)

    2005-09-15

    The numerical solution of linear multi-energy-group neutron transport equation is required in several analyses in nuclear reactor physics and allied areas. Computer codes based on the discrete ordinates (Sn) method are commonly used for this purpose. These codes solve external source problem and K-eigenvalue problem. The overall solution technique involves solution of source problem in each energy group as intermediate procedures. Such a single-group source problem is solved by the so-called Source Iteration (SI) method. As is well-known, the SI-method converges very slowly for optically thick and highly scattering regions, leading to large CPU times. Over last three decades, many schemes have been tried to accelerate the SI; the most prominent being the Diffusion Synthetic Acceleration (DSA) scheme. The DSA scheme, however, often fails and is also rather difficult to implement. In view of this, in 1997, Ramone and others have developed a new acceleration scheme called Transport Synthetic Acceleration (TSA) which is much more robust and easy to implement. This scheme has been recently incorporated in 2-D and 3-D in-house codes at BARC. This report presents studies on the utility of TSA scheme for fairly general test problems involving many energy groups and anisotropic scattering. The scheme is found to be useful for problems in Cartesian as well as Cylindrical geometry. (author)

  2. Transport synthetic acceleration scheme for multi-dimensional neutron transport problems

    International Nuclear Information System (INIS)

    Modak, R.S.; Vinod Kumar; Menon, S.V.G.; Gupta, Anurag

    2005-09-01

    The numerical solution of linear multi-energy-group neutron transport equation is required in several analyses in nuclear reactor physics and allied areas. Computer codes based on the discrete ordinates (Sn) method are commonly used for this purpose. These codes solve external source problem and K-eigenvalue problem. The overall solution technique involves solution of source problem in each energy group as intermediate procedures. Such a single-group source problem is solved by the so-called Source Iteration (SI) method. As is well-known, the SI-method converges very slowly for optically thick and highly scattering regions, leading to large CPU times. Over last three decades, many schemes have been tried to accelerate the SI; the most prominent being the Diffusion Synthetic Acceleration (DSA) scheme. The DSA scheme, however, often fails and is also rather difficult to implement. In view of this, in 1997, Ramone and others have developed a new acceleration scheme called Transport Synthetic Acceleration (TSA) which is much more robust and easy to implement. This scheme has been recently incorporated in 2-D and 3-D in-house codes at BARC. This report presents studies on the utility of TSA scheme for fairly general test problems involving many energy groups and anisotropic scattering. The scheme is found to be useful for problems in Cartesian as well as Cylindrical geometry. (author)

  3. Digital subtraction angiography in the evaluation of chemodectomas

    International Nuclear Information System (INIS)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-01-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required. (orig.) [de

  4. Digital subtraction angiography in the evaluation of chemodectomas

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-05-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required.

  5. The use of intravenous digital subtraction angiography in evaluating patients with complex congenital heart disease

    International Nuclear Information System (INIS)

    Moodie, D.S.

    1986-01-01

    The author previously described his experience in 450 patients with congenital heart disease using intravenous digital subtraction angiography (DSA) to define cardiac anatomy. He has been impressed by the utility of DSA in the evaluation of patients with congenital heart disease. It is now an integral part of his clinical practice to perform intravenous DSA studies both pre- and postoperatively on an inpatient as well as outpatient basis. This chapter details his DSA experience with complex forms of congenital heart disease

  6. Assessing User Needs and Requirements for Assistive Robots at Home.

    Science.gov (United States)

    Werner, Katharina; Werner, Franz

    2015-01-01

    'Robots in healthcare' is a very trending topic. This paper gives an overview of currently and commonly used methods to gather user needs and requirements in research projects in the field of assistive robotics. Common strategies between authors are presented as well as examples of exceptions, which can help future researchers to find methods suitable for their own work. Typical problems of the field are discussed and partial solutions are proposed.

  7. Rapid and efficient proteolysis through laser-assisted immobilized enzyme reactors.

    Science.gov (United States)

    Zhang, Peng; Gao, Mingxia; Zhu, Shaochun; Lei, Jie; Zhang, Xiangmin

    2011-11-25

    In this report, laser radiation (808nm) for the first time was employed to enhance the efficiency of proteolysis through immobilized enzyme reactor (IMER). IMER based monolithic support was prepared in the fused-silica capillary via a simple two-step procedure including acryloylation on trypsin surface and in situ aqueous polymerization/immobilization. The feasibility and high efficiency of the laser-assisted IMER were demonstrated by the digestion of bovine serum albumin (BSA), cytochrome c (Cyt-c) and β-casein. The digestion process was achieved in 60s. The peptides were identified by MALDI-TOF-MS, yielding the sequence coverage of 33% for BSA, 73% for Cyt-c and 22% for β-casein. The comparisons between the in-solution digestion and on IMER reaction with/without laser assistance were made. To further confirm its efficiency in proteome analysis, the laser-assisted IMER was also applied to the analysis of one fraction of human serum sample through two-dimensional (2-D) separation of strong anion exchange/reversed-phase liquid chromatography (SAX/RPLC). After a database search, 49 unique peptides corresponding to 5 proteins were identified. The results showed that the laser-assisted IMER provides a promising platform for the high-throughput protein identification. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Exploiting Sequential Patterns Found in Users' Solutions and Virtual Tutor Behavior to Improve Assistance in ITS

    Science.gov (United States)

    Fournier-Viger, Philippe; Faghihi, Usef; Nkambou, Roger; Nguifo, Engelbert Mephu

    2010-01-01

    We propose to mine temporal patterns in Intelligent Tutoring Systems (ITSs) to uncover useful knowledge that can enhance their ability to provide assistance. To discover patterns, we suggest using a custom, sequential pattern-mining algorithm. Two ways of applying the algorithm to enhance an ITS's capabilities are addressed. The first is to…

  9. Caractérisation des solutions de tensio-actif utilisées en récupération assistée Characterization of Surfactant Solutions Used in Enhanced Recovery

    Directory of Open Access Journals (Sweden)

    Moulu J. C.

    2006-11-01

    Full Text Available Des solutions de tensio-actif sont étudiées en vue de déterminer celles qui doivent être les plus efficaces pour le déplacement d'huile résiduelle en milieu poreux. Selon les propriétés de ces solutions au moment de leur injection, un banc d'huile se forme rapidement et progresse au niveau du front de tensio-actif, ou au contraire, les globules d'huile sont entraînés avec une vitesse faible dans l'ensemble du bouchon, les échanges entre les phases peuvent alors être importants. On a donc cherché à évaluer les caractéristiques des solutions en tenant compte des échanges qu'elles ont pu avoir avec l'huile et en particulier dans les deux cas extrêmes : solutions aqueuses sans huile et solutions équilibrées avec un grand volume d'huile. Pour ces deux états des solutions aqueuses, on a mis en évidence des comportements rhéologiques et interfaciaux très différents, dus à la migration d'alcool et d'huile entre les phases en présence. Ces propriétés des solutions de tensio-actif ont par ailleurs été reliées à la présence de structures cristallines et à leur transformation au cours des échanges qui se produisent. Research is being done on surfactant solutions to determine the ones that should be the most efficient for driving residual oil in porous media. Depending on the properties of these solutions at the time of their injection, an oil bank is formed quickly and progresses at the level of the surfactant front or, on the contrary, the oil ganglia are displaced slowly in the slug as a whole, and exchanges between the phases may then be great. Therefore, an effort was made to assess the characteristics of solutions while considering the exchanges they may have had with the oil, and particularly in the two extreme cases, i. e. aqueous solutions without oil and equilibrated solutions with a large volume of oil. For these two states of aqueous solutions, very different rheological and interfacial behaviors were found as

  10. Traumatic rupture of the aorta

    International Nuclear Information System (INIS)

    Dorfman, G.S.; Paolella, L.P.; Haas, R.A.; Lambiase, R.E.; Cronan, J.J.

    1988-01-01

    To evaluate the acceptability of digital subtraction angiography (DSA) in the evaluation of traumatic rupture of the aorta (TRA), the authors obtained 56 thoracic aortograms in 55 consecutive trauma patients, using both DSA and cut-film angiography (CFA). Both studies were ranked blindly and assigned scores for quality and diagnosis. Interobserver variance for DSA and CFA quality rankings was insignificant. CFA achieved significantly higher ranking for quality. In the 56 examinations, CFA demonstrated seven abnormalities that demanded intervention for follow-up angiography. DSA demonstrated only five of these and found no additional abnormalities. While this evaluation applies only to the particular digital system that the authors tested, they found that DSA, as compared with CFA, failed to demonstrate significant aortic injury. The confidence of diagnosis was significantly greater with CFA. Similar double-blind evaluation is mandatory at any trauma center prior to converting from CFA to DSA in the diagnosis of this life-threatening condition

  11. Numerical solution of electrostatic problems of the accelerator project VICKSI

    International Nuclear Information System (INIS)

    Janetzki, U.

    1975-03-01

    In this work, the numerical solution to a few of the electrostatic problems is dealt with which have occured within the framework of the heavy ion accelerator project VICKSI. By means of these selected examples, the versatile applicability of the numerical method is to be demonstrated, and simultaneously assistance is given for the solution of similar problems. The numerical process for solving ion-optics problems consists generally of two steps. In the first step, the potential distribution for a given boundary value problem is iteratively calculated for the Laplace equation, and then the image characteristics of the electostatic lense are investigated using the Raytrace method. (orig./LH) [de

  12. Epitaxial ternary nitride thin films prepared by a chemical solution method

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Hongmei [Los Alamos National Laboratory; Feldmann, David M [Los Alamos National Laboratory; Wang, Haiyan [TEXAS A& M; Bi, Zhenxing [TEXAS A& M

    2008-01-01

    It is indispensable to use thin films for many technological applications. This is the first report of epitaxial growth of ternary nitride AMN2 films. Epitaxial tetragonal SrTiN2 films have been successfully prepared by a chemical solution approach, polymer-assisted deposition. The structural, electrical, and optical properties of the films are also investigated.

  13. Model-assisted template extraction SRAF application to contact holes patterns in high-end flash memory device fabrication

    Science.gov (United States)

    Seoud, Ahmed; Kim, Juhwan; Ma, Yuansheng; Jayaram, Srividya; Hong, Le; Chae, Gyu-Yeol; Lee, Jeong-Woo; Park, Dae-Jin; Yune, Hyoung-Soon; Oh, Se-Young; Park, Chan-Ha

    2018-03-01

    Sub-resolution assist feature (SRAF) insertion techniques have been effectively used for a long time now to increase process latitude in the lithography patterning process. Rule-based SRAF and model-based SRAF are complementary solutions, and each has its own benefits, depending on the objectives of applications and the criticality of the impact on manufacturing yield, efficiency, and productivity. Rule-based SRAF provides superior geometric output consistency and faster runtime performance, but the associated recipe development time can be of concern. Model-based SRAF provides better coverage for more complicated pattern structures in terms of shapes and sizes, with considerably less time required for recipe development, although consistency and performance may be impacted. In this paper, we introduce a new model-assisted template extraction (MATE) SRAF solution, which employs decision tree learning in a model-based solution to provide the benefits of both rule-based and model-based SRAF insertion approaches. The MATE solution is designed to automate the creation of rules/templates for SRAF insertion, and is based on the SRAF placement predicted by model-based solutions. The MATE SRAF recipe provides optimum lithographic quality in relation to various manufacturing aspects in a very short time, compared to traditional methods of rule optimization. Experiments were done using memory device pattern layouts to compare the MATE solution to existing model-based SRAF and pixelated SRAF approaches, based on lithographic process window quality, runtime performance, and geometric output consistency.

  14. Alloantibodies in Organ Transplant: A Review of Data Published in 2015.

    Science.gov (United States)

    Maehara, Curtis; Everly, Matthew J

    2015-01-01

    In recent years, there have been multiple studies published on longitudinal and retrospective analysis of anti-human leukocyte antigen (anti-HLA) antibodies. The focus of these reports was to determine specific characteristics of the impact of donor specific anti-HLA antibodies (DSA) in organ transplantation. There has been a growing concern about DSA in a multitude of organ transplants. Research efforts are attempting to gain a better understanding of DSA and possible treatment implications for patients with DSA. In 2015, many studies confirm and expand upon both the understanding of the humoral theory and the clinical applications of DSA in transplantation. This review highlights some of these publications and their contributions to the humoral theory of transplantation. Copyright© 2016 by the Terasaki Foundation Laboratory.

  15. Renal transplantation across the donor-specific antibody barrier: Graft outcome and cancer risk after desensitization therapy.

    Science.gov (United States)

    Yang, Ching-Yao; Lee, Chih-Yuan; Yeh, Chi-Chuan; Tsai, Meng-Kun

    2016-06-01

    Desensitization regimens including use of intravenous immune globulin and rituximab have been reported to overcome renal transplant hyperacute rejection. A retrospective case-control study was performed to assess the results and complications of renal transplantation with desensitization therapy for donor-specific antibody (DSA) in a transplant center in Asia, where donor exchange was usually not allowed. Between January 2007 and December 2013, 22 patients with DSA received live-donor renal transplantation after desensitization (DSA group). During the same period, the DSA group was compared to the NSA group (152 renal transplants) who had no specific antibody to the donors (66 from deceased donors and 86 from living relatives). Rejection, renal function, graft and patient survival rates, infection, and cancer incidence were reviewed and analyzed from medical records. The DSA group (46.8%) had significantly higher acute rejection rates than the NSA group (13.7%) at the 1-year follow-up. The estimated renal function, 5-year graft, and patient survival rates were comparable between the groups. The DSA group (19.6%) had significantly higher 5-year de novo cancer incidence than the NSA group (8.5%; p = 0.028); three patients of the DSA group developed urothelial carcinoma 17.0 ± 3.0 months after transplantation. By using stepwise Cox regression analysis, desensitization therapy was identified as the sole independent risk factor for post-transplant urothelial carcinoma. When compared to renal transplantation without DSA, desensitization therapy for DSA resulted in equivalent renal transplant outcome but potentially increased risk of urothelial carcinoma after transplantation. Copyright © 2015. Published by Elsevier B.V.

  16. Microwave-assisted extraction of pectin from cocoa peel

    Science.gov (United States)

    Sarah, M.; Hanum, F.; Rizky, M.; Hisham, M. F.

    2018-02-01

    Pectin is a polymer of d-galacturonate acids linked by β-1,4 glycosidic bond. This study isolates pectin from cocoa peel (Theobroma cacao) using citric acid as solvent by microwave-assisted extraction method. Cocoa peels (moisture content of 10%) with citric acid solution (pH of 1.5) irradiated by microwave energy at various microwave power (180, 300, 450 and 600 W) for 10, 15, 20, 25 and 30 minutes respectively. Pectin obtained from this study was collected and filtrated by adding 96% ethanol to precipitate the pectin. The best results obtained from extraction process using microwave power of 180 Watt for 30 minutes. This combination of power and time yielded 42.3% pectin with moisture content, ash content, weight equivalent, methoxyl content and galacturonate levels were 8.08%, 5%, 833.33 mg, 6.51% and 58,08%, respectively. The result finding suggested that microwave-assisted extraction method has a great potency on the commercial pectin production.

  17. Ultrasonic assisted extraction - an alternative for sample preparation (M4)

    International Nuclear Information System (INIS)

    Santos Junior, P.; Barbosa Junior, F.; Krug, F.J.; Trevizan, L.C.; Nobrega, J.A.

    2002-01-01

    Full text: In the last years the ultrasound assisted metal extraction has been frequency proposed as a simple and inexpensive alternative for sample preparation of biological and inorganic samples. The extraction effect is considered as being caused by acoustic cavitation, that is, bubble formation and subsequent disruptive action. The collapse of bubbles created by sonication of solutions results in the generation of extremely high local temperature and pressure gradients, which may be regarded as localized 'hot spots'. On a timescale of about 10 -10 s, effective local pressures and temperature of about 10 5 atm and about 5000 K, respectively, are generated under sonochemical conditions. Usually, this method uses a diluted acid medium decreasing blank values and reducing both reagents and time consumption compared to traditional wet digestion systems using conductive or microwave-assisted heating. Furthermore, sonication can also allow the preparation of samples directly within the sample container, thereby preventing sample losses and minimizing sample contamination. Although some controversial results concerning metals extraction behavior have been reported, they could be explained by analyte-matrix interaction and the ability of the ultrasonic processor to generate ultrasound (i.e. the use of an ultrasonic bath or an ultrasonic probe at different power, frequency, and amplitude). This contribution presents a review of ultrasound assisted metal extraction and recent performance data obtained in our laboratory for determination of elements in biological materials, soils and sediments by ICP-OES and ETAAS. The effect of extraction parameters, such as type and concentration of the leaching solution, sonication time and performance of ultrasonic processor (bath or probe) will be presented. (author)

  18. ABS 3D printed solutions for cryogenic applications

    Science.gov (United States)

    Bartolomé, E.; Bozzo, B.; Sevilla, P.; Martínez-Pasarell, O.; Puig, T.; Granados, X.

    2017-03-01

    3D printing has become a common, inexpensive and rapid prototyping technique, enabling the ad hoc fabrication of complex shapes. In this paper, we demonstrate that 3D printed objects in ABS can be used at cryogenic temperatures, offering flexible solutions in different fields. Firstly, a thermo-mechanical characterization of ABS 3D printed specimens at 77 K is reported, which allowed us to delimit the type of cryogenic uses where 3D printed pieces may be implemented. Secondly, we present three different examples where ABS 3D printed objects working at low temperatures have provided specific solutions: (i) SQUID inserts for angular magnetometry (low temperature material characterization field); (ii) a cage support for a metamaterial ;magnetic concentrator; (superconductivity application), and (iii) dedicated tools for cryopreservation in assisted reproductive techniques (medicine field).

  19. SAR Observation and Numerical Simulation of Internal Solitary Wave Refraction and Reconnection Behind the Dongsha Atoll

    Science.gov (United States)

    Jia, T.; Liang, J. J.; Li, X.-M.; Sha, J.

    2018-01-01

    The refraction and reconnection of internal solitary waves (ISWs) around the Dongsha Atoll (DSA) in the northern South China Sea (SCS) are investigated based on spaceborne synthetic aperture radar (SAR) observations and numerical simulations. In general, a long ISW front propagating from the deep basin of the northern SCS splits into northern and southern branches when it passes the DSA. In this study, the statistics of Envisat Advanced SAR (ASAR) images show that the northern and southern wave branches can reconnect behind the DSA, but the reconnection location varies. A previously developed nonlinear refraction model is set up to simulate the refraction and reconnection of the ISWs behind the DSA, and the model is used to evaluate the effects of ocean stratification, background currents, and incoming ISW characteristics at the DSA on the variation in reconnection locations. The results of the first realistic simulation agree with consecutive TerraSAR-X (TSX) images captured within 12 h of each other. Further sensitivity simulations show that ocean stratification, background currents, and initial wave amplitudes all affect the phase speeds of wave branches and therefore shift their reconnection locations while shapes and locations of incoming wave branches upstream of the DSA profoundly influence the subsequent propagation paths. This study clarifies the variation in reconnection locations of ISWs downstream of the DSA and reveals the important mechanisms governing the reconnection process, which can improve our understanding of the propagation of ISWs near the DSA.

  20. Ultrasound-assisted powder-coating technique to improve content uniformity of low-dose solid dosage forms

    DEFF Research Database (Denmark)

    Genina, Natalja; Räikkönen, Heikki; Antikainen, Osmo

    2010-01-01

    An ultrasound-assisted powder-coating technique was used to produce a homogeneous powder formulation of a low-dose active pharmaceutical ingredient (API). The powdered particles of microcrystalline cellulose (MCC; Avicel® PH-200) were coated with a 4% m/V aqueous solution of riboflavin sodium...

  1. Microwave assisted synthesis of luminescent carbonaceous nanoparticles from silk fibroin for bioimaging.

    Science.gov (United States)

    Gao, Hongzhi; Teng, Choon Peng; Huang, Donghong; Xu, Wanqing; Zheng, Chaohui; Chen, Yisong; Liu, Minghuan; Yang, Da-Peng; Lin, Ming; Li, Zibiao; Ye, Enyi

    2017-11-01

    Bombyx mori silk as a natural protein based biopolymer with high nitrogen content, is abundant and sustainable because of its mass product all over the world per year. In this study, we developed a facile and fast microwave-assisted synthesis of luminescent carbonaceous nanoparticles using Bombyx mori silk fibroin and silk solution as the precursors. As a result, the obtained carbonaceous nanoparticles exhibit a photoluminescence quantum yield of ~20%, high stability, low cytotoxicity, high biocompatibility. Most importantly, we successfully demonstrated bioimaging using these luminescent carbonaceous nanoparticles with excitation dependent luminescence. In addition, the microwave-assisted hydrothermal method can be extended to convert other biomass into functional nanomaterials. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Parameter estimation by Differential Search Algorithm from horizontal loop electromagnetic (HLEM) data

    Science.gov (United States)

    Alkan, Hilal; Balkaya, Çağlayan

    2018-02-01

    We present an efficient inversion tool for parameter estimation from horizontal loop electromagnetic (HLEM) data using Differential Search Algorithm (DSA) which is a swarm-intelligence-based metaheuristic proposed recently. The depth, dip, and origin of a thin subsurface conductor causing the anomaly are the parameters estimated by the HLEM method commonly known as Slingram. The applicability of the developed scheme was firstly tested on two synthetically generated anomalies with and without noise content. Two control parameters affecting the convergence characteristic to the solution of the algorithm were tuned for the so-called anomalies including one and two conductive bodies, respectively. Tuned control parameters yielded more successful statistical results compared to widely used parameter couples in DSA applications. Two field anomalies measured over a dipping graphitic shale from Northern Australia were then considered, and the algorithm provided the depth estimations being in good agreement with those of previous studies and drilling information. Furthermore, the efficiency and reliability of the results obtained were investigated via probability density function. Considering the results obtained, we can conclude that DSA characterized by the simple algorithmic structure is an efficient and promising metaheuristic for the other relatively low-dimensional geophysical inverse problems. Finally, the researchers after being familiar with the content of developed scheme displaying an easy to use and flexible characteristic can easily modify and expand it for their scientific optimization problems.

  3. Microwave-assisted synthesis of bismuth oxybromochloride nanoflakes for visible light photodegradation of pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Bijanzad, Keyvan; Tadjarodi, Azadeh; Moghaddasi Khiavi, Mohammad [Research Laboratory of Inorganic Materials Synthesis, Department of Chemistry, Iran University of Science and Technology, Narmak, Tehran 16846-13114 (Iran, Islamic Republic of); Akhavan, Omid, E-mail: oakhavan@sharif.ir [Department of Physics, Sharif University of Technology, P.O. Box 11155-9161, Tehran (Iran, Islamic Republic of); Institute for Nanoscience and Nanotechnology, Sharif University of Technology, P.O. Box 14588-89694, Tehran (Iran, Islamic Republic of)

    2015-10-15

    BiOBr{sub x}Cl{sub 1−x} (0assisted synthesis method. The X-ray diffraction (XRD) studies confirmed the formation of pure crystalline phase of BiOBr{sub x}Cl{sub 1−x}. The UV–visible diffuse reflectance and photoluminescence (PL) spectroscopies revealed the indirect band gap of ~2.82 eV for the bismuth oxybromochloride nanoflakes. Visible light-assisted photocatalytic studies showed that the degradation efficiency of the as-prepared BiOBr{sub x}Cl{sub 1−x} for (100 mL of 10 mg L{sup −1}) Rhodamine B (RhB), Natural Red 4 (N-Red) dye solutions was 98.14% and for the colorless organic pentachlorophenol (PCP) solution was 91.09% over 150 min. The possible mechanisms involved in the visible light photodegradation of the pollutants by BiOBr{sub x}Cl{sub 1−x} photocatalyst were also discussed.

  4. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  5. Ductile flow by water-assisted cataclasis

    Science.gov (United States)

    den Brok, Bas

    2003-04-01

    In the presence of water otherwise brittle materials may deform macroscopically ductile by water-assisted cataclastic creep. This is possible as long as (i) solubility is high enough, so that stress-corrosion can occur, and (ii) local stress is low enough, to that fracturing remains subcritical. Water-assisted cataclastic creep (WACC) may play an important role in the middle and lower continental crust where mineral solubilities are high and stresses low. WACC is a poorly understood deformation process. Experiments were performed on very soluble brittle salts (Na-chlorate; K-alum) to study microstructure development by WACC. The experiments were carried out at room temperature and atmospheric pressure in a small see-through vessel. In this way the cataclastic deformation process could be studied "in-situ" under the microscope. Crystals were loaded in the presence of saturated salt solution. It appeared that originally straight mineral surfaces were instable when kept under stress. Grooves (or channels) slowly developed in the surface by local dissolution. These grooves behave like so-called Grinfeld instabilities. They develop because the energy of a grooved surface under stress is lower than the energy of a straight surface under stress. The grooves may deepen and turn into subcritical cracks when local stress further increases. These cracks propagate slowly. They propagate parallel to sigma1 but also at an angle and even perpendicular to sigma1, often following crystallographically controlled directions. The fractures mostly change direction while propagating, locally making turns of more than 180 degrees. Irregular fracture fragments thus develop. The fractures may migrate sideways (as with grain bounday migration) probably by solution-redeposition driven by differences in stress between both sides of the fracture. Thus the shape of the fragments changes. The size of the fracture fragments seems to be controlled by the distance of the grooves, which decreases

  6. A History of Aerospace Problems, Their Solutions, Their Lessons

    Science.gov (United States)

    Ryan, R. S.

    1996-01-01

    The positive aspect of problem occurrences is the opportunity for learning and a challenge for innovation. The learning aspect is not restricted to the solution period of the problem occurrence, but can become the beacon for problem prevention on future programs. Problems/failures serve as a point of departure for scaling to new designs. To ensure that problems/failures and their solutions guide the future programs, a concerted effort has been expended to study these problems, their solutions, their derived lessons learned, and projections for future programs. This includes identification of technology thrusts, process changes, codes development, etc. However, they must not become an excuse for adding layers upon layers of standards, criteria, and requirements, but must serve as guidelines that assist instead of stifling engineers. This report is an extension of prior efforts to accomplish this task. Although these efforts only scratch the surface, it is a beginning that others must complete.

  7. Laser Assisted Free-Free Transition in Electron - Atom Collision

    Science.gov (United States)

    Sinha, C.; Bhatia, A. K.

    2011-01-01

    Free-free transition is studied for electron-Hydrogen atom system in ground state at very low incident energies in presence of an external homogeneous, monochromatic and linearly polarized laser field. The incident electron is considered to be dressed by the laser in a non perturbative manner by choosing the Volkov solutions in both the channels. The space part of the scattering wave function for the electron is solved numerically by taking into account the effect of electron exchange, short range as well as of the long range interactions. Laser assisted differential as well as elastic total cross sections are calculated for single photon absorption/emission in the soft photon limit, the laser intensity being much less than the atomic field intensity. A strong suppression is noted in the laser assisted cross sections as compared to the field free situations. Significant difference is noted in the singlet and the triplet cross sections.

  8. Nanostructural and magnetic studies of virtually monodispersed NiFe2O4 nanocrystals synthesized by a liquid–solid-solution assisted hydrothermal route

    International Nuclear Information System (INIS)

    Li Xinghua; Tan Guoguo; Chen Wei; Zhou Baofan; Xue Desheng; Peng Yong; Li, Fashen; Mellors, Nigel J.

    2012-01-01

    This study presents a comprehensively and systematically structural, chemical and magnetic characterization of ∼9.5 nm virtually monodispersed nickel ferrite (NiFe 2 O 4 ) nanoparticles prepared using a modified liquid–solid-solution (LSS) assisted hydrothermal method. Lattice-resolution scanning transmission electron microscope (STEM) and converged beam electron diffraction pattern (CBED) techniques are adapted to characterize the detailed spatial morphology and crystal structure of individual NiFe 2 O 4 particles at nano scale for the first time. It is found that each NiFe 2 O 4 nanoparticle is single crystal with an fcc structure. The morphology investigation reveals that the prepared NiFe 2 O 4 nanoparticles of which the surfaces are decorated by oleic acid are dispersed individually in hexane. The chemical composition of nickel ferrite nanoparticles is measured to be 1:2 atomic ratio of Ni:Fe, indicating a pure NiFe 2 O 4 composition. Magnetic measurements reveal that the as-synthesized nanocrystals displayed superparamagnetic behavior at room temperature and were ferromagnetic at 10 K. The nanoscale characterization and magnetic investigation of monodispersed NiFe 2 O 4 nanoparticles should be significant for its potential applications in the field of biomedicine and magnetic fluid using them as magnetic materials.

  9. Free radical formation in deoxyguanosine-5'-monophosphate γ-irradiated in frozen solution. A computer-assisted analysis of temperature-dependent ESR spectra

    International Nuclear Information System (INIS)

    Gregoli, S.; Olast, M.; Bertinchamps, A.

    1977-01-01

    Deoxyguanosine-5'-monophosphate (dGMP) was γ-irradiated at 77 K in frozen aqueous solution and then annealed in a stepwise fashion up to the melting point. During this process, the primary radicals formed in DGMP at 77 K are progressively converted into secondary radical species. This is observed as changes in the spectrum intensity and conformation. Computer-assisted analysis of these temperature-dependent spectra permitted us to identify the transient radical species involved and to draw up single-radical concentration kinetics vs temperature. The radiation chemical behavior of dGMP was found to be quite similar to that of dAMP, investigated previously. In both these purine derivatives, radical anions are converted into radicals of H-addition to C-8, and radical cations are converted into radicals of OH-addition to the same position. In dGMP, however, the cationic channel is only induced under certain experimental conditions (alkaline pH, presence of electron scavengers). At neutral pH, G + radicals are quite stable and finally become deactivated without being converted into secondary GOH radicals. Specific deuterium substitution at carbon C-8, and irradiation in H 2 O or in D 2 O, confirmed that both H + and OH - attachments do occur at C-8, and that both the H + and OH - groups come from the aqueous medium

  10. A Novel Consensus-Based Particle Swarm Optimization-Assisted Trust-Tech Methodology for Large-Scale Global Optimization.

    Science.gov (United States)

    Zhang, Yong-Feng; Chiang, Hsiao-Dong

    2017-09-01

    A novel three-stage methodology, termed the "consensus-based particle swarm optimization (PSO)-assisted Trust-Tech methodology," to find global optimal solutions for nonlinear optimization problems is presented. It is composed of Trust-Tech methods, consensus-based PSO, and local optimization methods that are integrated to compute a set of high-quality local optimal solutions that can contain the global optimal solution. The proposed methodology compares very favorably with several recently developed PSO algorithms based on a set of small-dimension benchmark optimization problems and 20 large-dimension test functions from the CEC 2010 competition. The analytical basis for the proposed methodology is also provided. Experimental results demonstrate that the proposed methodology can rapidly obtain high-quality optimal solutions that can contain the global optimal solution. The scalability of the proposed methodology is promising.

  11. Four-dimensional computed tomography angiographic evaluation of cranial dural arteriovenous fistula before and after embolization

    International Nuclear Information System (INIS)

    Tian, Bing; Xu, Bing; Lu, Jianping; Liu, Qi; Wang, Li; Wang, Minjie

    2015-01-01

    Highlights: • 4D CTA showed excellent agreement with DSA with regard to identification of feeding arteries and drainage veins. • The most important finding was 4D CTA in determining the impact of DAVF treatment with transarterial embolization. • 4D CTA provides images similar to those obtained with DSA both before and after treatment. - Abstract: Purpose: This study aimed to evaluate the usefulness of four-dimensional CTA before and after embolization treatment with ONYX-18 in eleven patients with cranial dural arteriovenous fistulas, and to compare the results with those of the reference standard DSA. Patients and Methods: Eleven patients with cranial dural arteriovenous fistulas detected on DSA underwent transarterial embolization with ONYX-18. Four-dimensional CTA was performed an average of 2 days before and 4 days after DSA. Four-dimensional CTA and DSA images were reviewed by two neuroradiologists for identification of feeding arteries and drainage veins and for determining treatment effects. Interobserver and intermodality agreement between four-dimensional CTA and DSA were assessed. Results: Forty-two feeding arteries were identified for 14 fistulas in the 11 patients. Of these, 36 (85.71%) were detected on four-dimensional CTA. After transarterial embolization, one patient got partly embolized, and the fistulas in the remaining 10 patients were completely occluded. The interobserver agreement for four-dimensional CTA and intermodality agreement between four-dimensional CTA and DSA were excellent (κ = 1) for shunt location, identification of drainage veins, and fistula occlusion after treatment. Conclusion: Four-dimensional CTA images are highly accurate when compared with DSA images both before and after transarterial embolization treatment. Four-dimensional CTA can be used for diagnosis as well as follow-up of cranial dural arteriovenous fistulas in clinical settings

  12. Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B., E-mail: hinrichs.jan@mh-hannover.de; Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Falck, Christian von, E-mail: falck.christian.von@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany); Hoeper, Marius M., E-mail: hoeper.marius@mh-hannover.de; Olsson, Karen M., E-mail: olsson.karen@mh-hannover.de [Hannover Medical School, Clinic for Pneumology, German Center for Lung Research (DZL) (Germany); Wacker, Frank K., E-mail: wacker.frank@mh-hannover.de; Meyer, Bernhard C., E-mail: meyer.bernhard@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany)

    2016-01-15

    PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

  13. Feasibility of magnetic resonance angiography (MRA) follow-up as the primary imaging modality after coiling of intracranial aneurysms

    International Nuclear Information System (INIS)

    Bakker, Nicolaas A.; Metzemaekers, Jan D. M.; Dijk, J. Marc C. van; Mooij, Jan Jakob A.; Groen, Rob J. M.; Westerlaan, Henriette E.; Eshghi, Omid S.

    2010-01-01

    Background: Digital subtraction angiography (DSA) is still regarded as the gold standard for detecting residual flow in treated aneurysms. Recent reports have also shown excellent results from magnetic resonance angiography (MRA) imaging. This is an important observation, since DSA is associated with a risk of medical complications, is time consuming, and is more expensive. Purpose: To determine whether MRA could replace conventional DSA and serve as the primary postinterventional imaging modality in patients with coiled intracranial aneurysms. Material and Methods: We studied a prospectively enrolled cohort of 190 patients treated endovascularly for a first-ruptured and/or unruptured intracranial aneurysm between January 2004 and December 2008. The imaging protocol included a 1.5T time-of-flight (TOF) MRA and a DSA at 3 months (on the same day) and, depending on comparability, a 1.5T TOF-MRA or DSA 1 year after treatment. All images were evaluated by a multidisciplinary panel. Results: In 141/190 patients, both an MRA and DSA were performed after 3-month follow-up. In 2/141 patients (1.4%), (small) neck remnants gave false-negative MRA results. In one patient (0.7%), this led to additional neurosurgical clipping of the aneurysm. In 25/141 patients, future follow-up (>3 months) consisted of DSA because of various reasons. In 24/25 of these patients, primary MRA images alone would invariably have led to additional DSA imaging. Conclusion: The present study shows that 1.5T TOF-MRA is a feasible primary follow-up modality after coiling of intracranial aneurysms. Given our data, we now suggest that, in every patient with a coiled intracranial aneurysm, the first follow-up, 3 months after coiling, should be an MRA study. Only when this MRA is inconclusive (e.g., because of coil artifacts), or in the case of suspicion of recanalization, should DSA be performed additionally

  14. Processing of C60 thin films by Matrix-Assisted Pulsed Laser Evaporation (MAPLE)

    DEFF Research Database (Denmark)

    Canulescu, Stela; Schou, Jørgen; Fæster, Søren

    2011-01-01

    Thin films of fullerenes (C60) were deposited onto silicon using matrix-assisted pulsed laser evaporation (MAPLE). The deposition was carried out from a frozen homogeneous dilute solution of C60 in anisole (0.67 wt%), and over a broad range of laser fluences, from 0.15 J/cm2 up to 3.9 J/cm2. MAPLE...

  15. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  16. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  17. Rare earth-based low-index films for IR and multispectral thin film solutions

    Science.gov (United States)

    Stolze, Markus; Neff, Joe; Waibel, Friedrich

    2017-10-01

    Non-thoriated rare-earth fluoride based coating solutions involving DyF3 and YbF3 based films as well as non-wetting fluorohydrocarbon cap layers on such films, have been deposited, analyzed and partly optimized. Intermediate results for DyF3 based films from ion assisted e-gun deposition with O2 and N2 alone and as base for the non-wetting to-player as well as for YbF3 starting material with or without admixtures of CaF2 are discussed for low-loss LWIR and multispectral solutions.

  18. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  19. The Effects of a Dynamic Spectrum Access Overlay in LTE-Advanced Networks

    Energy Technology Data Exchange (ETDEWEB)

    Juan D. Deaton; Ryan E. lrwin; Luiz A. DaSilva

    2011-05-01

    As early as 2014, wireless network operators spectral capacity will be overwhelmed by a data tsunami brought on by new devices and applications. To augment spectral capacity, operators could deploy a Dynamic Spectrum Access (DSA) overlay. In the light of the many planned Long Term Evolution (LTE) network deployments, the affects of a DSA overlay have not been fully considered into the existing LTE standards. Coalescing many different aspects of DSA, this paper develops the Spectrum Accountability (SA) framework. The SA framework defines specific network element functionality, protocol interfaces, and signaling flow diagrams for LTE to support service requests and enforce rights of responsibilities of primary and secondary users, respectively. We also include a network simulation to quantify the benefits of using DSA channels to augment capacity. Based on our simulation we show that, network operators can benefit up to %40 increase in operating capacity when sharing DSA bands to augment spectral capacity. With our framework, this paper could serve as an guide in developing future LTE network standards that include DSA.

  20. Robust control design for active driver assistance systems a linear-parameter-varying approach

    CERN Document Server

    Gáspár, Péter; Bokor, József; Nemeth, Balazs

    2017-01-01

    This monograph focuses on control methods that influence vehicle dynamics to assist the driver in enhancing passenger comfort, road holding, efficiency and safety of transport, etc., while maintaining the driver’s ability to override that assistance. On individual-vehicle-component level the control problem is formulated and solved by a unified modelling and design method provided by the linear parameter varying (LPV) framework. The global behaviour desired is achieved by a judicious interplay between the individual components, guaranteed by an integrated control mechanism. The integrated control problem is also formalized and solved in the LPV framework. Most important among the ideas expounded in the book are: application of the LPV paradigm in the modelling and control design methodology; application of the robust LPV design as a unified framework for setting control tasks related to active driver assistance; formulation and solution proposals for the integrated vehicle control problem; proposal for a re...

  1. Interactions from diffraction data: historical and comprehensive overview of simulation assisted methods

    International Nuclear Information System (INIS)

    Toth, Gergely

    2007-01-01

    A large part of statistical mechanics is concerned with the determination of condensed matter structure on the basis of known microscopic interactions. An increasing emphasis has been put on the opposite situation in the last decades as well, where structural data, e.g. pair-distance statistics, are known from diffraction experiments, and one looks for the corresponding interaction functions. The solution of this inverse problem was searched for within the integral equation theories of condensed matter in the early investigations, but before long computer simulation assisted methods were suggested. The interest in this field showed an increasing trend after some attempts appeared in the late 1980s. Several methods were published in the 1990s, and one-two methods appear annually nowadays. In this paper a comprehensive and historical overview is given on the solution of the inverse problem with simulation assisted methods. Emphasis is put on the theoretical grounds of the methods, on the choice of possible input structural functions, on the numerically local or global schemes of the potential modifications, on some advantages and limits of the different methods and on the scientific impact of the methods

  2. 78 FR 28642 - Eastman Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-05-15

    ... Kodak Company, Electrographic Print Solutions, Including On-Site Leased Workers From Adecco and Datrose, Spencerport, New York; Eastman Kodak Company, IPS, Including On-Site Leased Workers From Adecco, Dayton, Ohio... Trade Adjustment Assistance (TAA) filed on behalf of Eastman Kodak Company, Electrographic Print...

  3. Development of digital subtraction system DAR-1200

    International Nuclear Information System (INIS)

    Kawai, Masumi; Shimizu, Yasumitsu; Ozaki, Takeshi; Sawada, Hiroshi; Uzuyama, Kazuhiro; Nishioka, Hiroyuki

    1989-01-01

    Digital subtraction angiography (DSA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. The merits of Shimadzu high resolution digital subtraction system DAR-1200 are reported in this paper. Furthermore, the principle and clinical usefullness of a new method of DSA called the Peak-Hold DSA are explained especially in details. (author)

  4. Equine deep stromal abscesses (51 cases - 2004-2009)--Part 1: the clinical aspects with attention to the duration of the corneal disease, treatment history, clinical appearance, and microbiology results.

    Science.gov (United States)

    de Linde Henriksen, Michala; Andersen, Pia H; Thomsen, Preben D; Plummer, Caryn E; Mangan, Brendan; Heegaard, Steffen; Toft, Nils; Brooks, Dennis E

    2014-07-01

    To study the equine deep stromal abscesses (DSA) with focus on the duration of the corneal disease, medical treatment, season of presentation, clinical appearance, and the degree of corneal vascularization. Equine DSA diagnosed, biopsied, and surgically treated at the University of Florida Veterinary Medical Center (UFVMC) from 2004 to 2009 were identified. The medical record, clinical photographic images, and microbiology results for each case were evaluated. Frequency and prevalence calculation as well as qualitative data analysis was performed for clinical and microbiological data. Fifty-one equine DSA were included in the study. Spring (March, April, May; 33.4%) and winter (December, January, February; 31.4%) were the most common seasons for DSA presentation. The 51 cases were divided into four categories of focal opacity from their clinical appearance: focal yellow (45.2%), focal white (23.5%), diffuse yellow/white (23.5%), and focal pink (7.8%). 5.9% of the DSA (n = 3) were culture positive for fungal growth, whereas 17.6% were positive for bacterial growth (n = 9). No association between short-/long-term systemically administered NSAID treatment and the corneal vascular response to the corneal lesion could be appreciated. Equine DSA most often present in the spring and winter in the subtropical environment of the state of Florida (USA). The clinical appearance may have a connection with the etiology and pathogenesis of the equine DSA. No connection between short- or long-term systemically administered NSAID and the degree of corneal vascularization of the DSA was noted. © 2013 American College of Veterinary Ophthalmologists.

  5. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz, E-mail: moritzwildgruber@ukmuenster.de [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Institut für klinische Radiologie, Universitätsklinikum Münster, D-48149 Münster (Germany); Wrede, Christian E. [Notfallzentrum, Helios Klinikum Berlin-Buch, D-13125 Berlin (Germany); Zorger, Niels [Institut für Radiologie, Neuroradiologie und Nuklearmedizin, Krankenhaus Barmherzige Brüder, D-93049 Regensburg (Germany); Müller-Wille, René; Hamer, Okka W. [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Zeman, Florian [Zentrum für Klinische Studien, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Stroszczynski, Christian; Heiss, Peter [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany)

    2017-03-15

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  6. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wrede, Christian E.; Zorger, Niels; Müller-Wille, René; Hamer, Okka W.; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-01-01

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  7. Advantage and choice: social relationships and staff assistance in assisted living.

    Science.gov (United States)

    Burge, Stephanie; Street, Debra

    2010-05-01

    OBJECTIVES. To understand how "cumulative inequality" (CI), expressed as individual advantage and choice, and "external social supports" contribute to the quality of social relationships and perceptions of staff assistance for older individuals in different assisted living (AL) settings. Data are from 429 cognitively intact AL residents aged 60 years and older interviewed for the Florida Study of Assisted Living. Bivariate and multivariate statistical analyses show how individual advantage and choice and external social networks influence respondents' social relationships and staff assistance in AL. Controlling for resident and facility characteristics, being able to pay privately enhances resident satisfaction with staff assistance and having control over the move to AL is positively associated with perceptions of staff relationships and assistance. Maintaining contact with pre-AL friends predicts quality of coresident relationships, as does family contact. Regular contact with family buffers some of the disadvantages associated with CI for perceptions of staff relationships but not perceptions of staff assistance. Discussion. Individual advantage and choice influence the quality of staff relationships and assistance for AL residents but matter little for coresident relationships. External social relationships buffer some of the risks associated with CI for perceptions of staff relationships but not perceived quality of staff assistance. Findings highlight outcomes associated with CI, including predictable risks that disadvantaged elders face in particular types of AL settings, differential advantages others enjoy that influence positive perceptions of staff relationships and staff assistance, and the enduring importance of supportive social relationships.

  8. Rapid prototyping-assisted maxillofacial reconstruction.

    Science.gov (United States)

    Peng, Qian; Tang, Zhangui; Liu, Ousheng; Peng, Zhiwei

    2015-05-01

    Rapid prototyping (RP) technologies have found many uses in dentistry, and especially oral and maxillofacial surgery, due to its ability to promote product development while at the same time reducing cost and depositing a part of any degree of complexity theoretically. This paper provides an overview of RP technologies for maxillofacial reconstruction covering both fundamentals and applications of the technologies. Key fundamentals of RP technologies involving the history, characteristics, and principles are reviewed. A number of RP applications to the main fields of oral and maxillofacial surgery, including restoration of maxillofacial deformities and defects, reduction of functional bone tissues, correction of dento-maxillofacial deformities, and fabrication of maxillofacial prostheses, are discussed. The most remarkable challenges for development of RP-assisted maxillofacial surgery and promising solutions are also elaborated.

  9. Contrast media osmolality and plasma volume changes

    International Nuclear Information System (INIS)

    Hine, A.L.; Lui, D.; Dawson, P.; Middlesex Hospital, London

    1985-01-01

    A theoretical and experimental study of the plasma volume expansion consequent on the hyperosmolality of contrast media is presented. In the case of the ratio 1.5 media theory and experiment coincide closely but in the case of the ratio 3 media the observed changes exceed the predicted. It is proposed that this is due partly to the slower diffusion of the ratio 3 media out of the intravascular space and partly due to the fact that the osmotic load presented by these media is greater than would be expected from a study of their commercial solutions in which osmolality is reduced by molecular aggregation. The implications for the relative haemodynamic effects of different contrast media are discussed. The osmotic effects of contrast media also play a part in determining the image quality achievable in intravenous digital subtraction angiography (IV-DSA). It is predicted that ratio 3 contrast media will give better quality images in IV-DSA than ratio 1.5 media. (orig.)

  10. Microwave-assisted synthesis of iron oxide nanoparticles in biocompatible organic environment

    Science.gov (United States)

    Aivazoglou, E.; Metaxa, E.; Hristoforou, E.

    2018-04-01

    The development of magnetite and maghemite particles in uniform nanometer size has triggered the interest of the research community due to their many interesting properties leading to a wide range of applications, such as catalysis, nanomedicine-nanobiology and other engineering applications. In this study, a simple, time-saving and low energy-consuming, microwave-assisted synthesis of iron oxide nanoparticles, is presented. The nanoparticles were prepared by microwave-assisted synthesis using polyethylene glycol (PEG) or PEG and β-cyclodextrin (β-CD)/water solutions of chloride salts of iron in the presence of ammonia solution. The prepared nano-powders were characterized using X-Ray Diffraction (XRD), Transition Electron Microscopy (TEM), Fourier-transform Infrared Spectroscopy (FTIR), Raman Spectroscopy, Vibrating Sample Magnetometer (VSM), X-Ray Photoelectron Spectroscopy (XPS) and Thermal analysis (TG/DSC). The produced nanoparticles are crystallized mostly in the magnetite and maghemite lattice exhibiting very similar shape and size, with indications of partial PEG coating. Heating time, microwave power and presence of PEG, are the key factors shaping the size properties of nanoparticles. The average size of particles ranges from 10.3 to 19.2 nm. The nanoparticles exhibit a faceted morphology, with zero contamination levels. The magnetic measurements indicate that the powders are soft magnetic materials with negligible coercivity and remanence, illustrating super-paramagnetic behavior.

  11. Mechanisms of biochar assisted immobilization of Pb2+ by bioapatite in aqueous solution.

    Science.gov (United States)

    Shen, Zhengtao; Tian, Da; Zhang, Xinyu; Tang, Lingyi; Su, Mu; Zhang, Li; Li, Zhen; Hu, Shuijin; Hou, Deyi

    2018-01-01

    Bioapatite (BAp) is regarded as an effective material to immobilize lead (Pb 2+ ) via the formation of stable pyromorphite. However, when applied in contaminated soil, due to its low surface area and low adsorption capacity, BAp might not sufficiently contact and react with Pb 2+ . Biochar, a carbon storage material, typically has high surface area and high adsorption capacity. This study investigated the feasibility of using biochar as a reaction platform to enhance BAp immobilization of Pb 2+ . An alkaline biochar produced from wheat straw pellets (WSP) and a slightly acidic biochar produced from hardwood (SB) were selected. The results of aqueous adsorption showed the combination of biochar (WSP or SB) and BAp effectively removed Pb 2+ from the aqueous solution containing 1000 ppm Pb 2+ . XRD, ATR-IR, and SEM/EDX results revealed the formation of hydroxypyromorphite on both biochars' surfaces. This study demonstrates that biochars could act as an efficient reaction platform for BAp and Pb 2+ in aqueous solution due to their high surface area, porous structure, and high adsorption capacity. Therefore, it is mechanistically feasible to apply biochar to enhance BAp immobilization of Pb 2+ in contaminated soil. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Assisted Vaginal Delivery

    Science.gov (United States)

    ... Education & Events Advocacy For Patients About ACOG Assisted Vaginal Delivery Home For Patients Search FAQs Assisted Vaginal ... Vaginal Delivery FAQ192, February 2016 PDF Format Assisted Vaginal Delivery Labor, Delivery, and Postpartum Care What is ...

  13. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  14. A Robotic Solution for Assisting People with MCI at Home: Preliminary Tests of the ENRICHME System.

    Science.gov (United States)

    Salatino, Claudia; Pigini, Lucia; Van Kol, Marlies Maria Elisabeth; Gower, Valerio; Andrich, Renzo; Munaro, Giulia; Rosso, Roberto; Castellani, Angelo P; Farina, Elisabetta

    2017-01-01

    Robots have the potential to support care and independence of older adults. The ENRICHME project is developing an integrated system composed of a robot, sensors and a networking care platform, aiming at assisting older adults with MCI in their home environment. This paper reports findings of the tests performed on a sample of MCI users and their caregivers, with the first version of the ENRICHME system, in a controlled environment.

  15. Magnetic resonance angiography in suspected cerebral vasculitis

    International Nuclear Information System (INIS)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido; Maes, Frederik; Velghe, Beatrijs

    2004-01-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  16. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy?

    International Nuclear Information System (INIS)

    Cosottini, M.; Calabrese, R.; Murri, L.; Puglioli, M.; Zampa, V.; Michelassi, M.C.; Ortori, S.; Bartolozzi, C.

    2003-01-01

    The aim of this study was to evaluate diagnostic accuracy of contrast-enhanced MRA (CEMRA) compared with digital subtraction angiography (DSA) in studying neck vessels of 48 patients. In three groups of patients, we used three MRA protocols differing for voxel size to assess if intravoxel dephasing effects could modify accuracy of CEMRA. Accuracy and correlation with DSA results were calculated in all patients and separately in the three groups. A qualitative analysis of the likeness between morphology of the stenosis in CEMRA and DSA images was also assessed. In all patients accuracy and agreement with DSA were 96% and k=0.85 in subclavian arteries, 96% and k=0.84 in vertebral artery, 97% and k=0.88 in common carotid arteries, and 94% and k=0.86 in internal carotid arteries. In the three groups accuracy and agreement with DSA did not show any significant difference. Qualitative analysis of CEMRA and DSA images revealed a better agreement in depicting the morphology of stenosis using a smaller voxel size. The CEMRA represents a powerful tool for the non-invasive evaluation of neck vessels. Overestimation trend of CEMRA is confirmed and the reduction of voxel size, decreasing the dephasing intravoxel effect, allows to have a better overlapping of stenosis morphology on CEMRA compared with DSA, but it does not yield diagnostic gain in the stenosis grading. (orig.)

  17. Magnetic resonance angiography in suspected cerebral vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, Philippe; De Ruyter, Nele; Wilms, Guido [Department of Radiology, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Maes, Frederik [Department of Medical Imaging Computing, Universitair Ziekenhuis, KU Leuven, 3000, Leuven (Belgium); Velghe, Beatrijs [Department of Radiology, Ziekenhuis Oost-Limburg, Schiepse Bos 6, 3600, Genk (Belgium)

    2004-06-01

    The purpose of this study was to determine the technical capacity and diagnostic accuracy of 3D time-of-flight magnetic resonance angiography (MRA) in suspected cerebral vasculitis in a retrospective analysis of MRA and digital subtraction angiography (DSA) in 14 young patients with clinical and/or radiological suspicion of cerebral vasculitis. A total of nine arteries were evaluated in each patient. Consensus review of DSA by three observers was the reference standard. The sensitivity for detecting a stenosis varied from 62 to 79% for MRA and from 76 to 94% for DSA, depending on the observer. The specificity for detecting a stenosis varied from 83 to 87% for MRA and from 83 to 97% for DSA. Using the criterion ''more than two stenoses in at least two separate vascular distributions'' to consider the examination as being true positive, the false-positive rates for MRA and DSA were comparable. MRA plays a role as the first angiographical examination in the diagnostic work-up of suspected cerebral vasculitis. When more than two stenoses in at least two separate vascular distributions are depicted on MRA, DSA is not expected to add a significant diagnostic contribution in a patient with suspected cerebral vasculitis. DSA remains necessary when MRA is normal or when less than three stenoses are seen. (orig.)

  18. Four-dimensional computed tomography angiographic evaluation of cranial dural arteriovenous fistula before and after embolization.

    Science.gov (United States)

    Tian, Bing; Xu, Bing; Lu, Jianping; Liu, Qi; Wang, Li; Wang, Minjie

    2015-06-01

    This study aimed to evaluate the usefulness of four-dimensional CTA before and after embolization treatment with ONYX-18 in eleven patients with cranial dural arteriovenous fistulas, and to compare the results with those of the reference standard DSA. Eleven patients with cranial dural arteriovenous fistulas detected on DSA underwent transarterial embolization with ONYX-18. Four-dimensional CTA was performed an average of 2 days before and 4 days after DSA. Four-dimensional CTA and DSA images were reviewed by two neuroradiologists for identification of feeding arteries and drainage veins and for determining treatment effects. Interobserver and intermodality agreement between four-dimensional CTA and DSA were assessed. Forty-two feeding arteries were identified for 14 fistulas in the 11 patients. Of these, 36 (85.71%) were detected on four-dimensional CTA. After transarterial embolization, one patient got partly embolized, and the fistulas in the remaining 10 patients were completely occluded. The interobserver agreement for four-dimensional CTA and intermodality agreement between four-dimensional CTA and DSA were excellent (κ=1) for shunt location, identification of drainage veins, and fistula occlusion after treatment. Four-dimensional CTA images are highly accurate when compared with DSA images both before and after transarterial embolization treatment. Four-dimensional CTA can be used for diagnosis as well as follow-up of cranial dural arteriovenous fistulas in clinical settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. High risk of graft failure in patients with anti-HLA antibodies undergoing haploidentical stem-cell transplantation.

    Science.gov (United States)

    Ciurea, Stefan O; de Lima, Marcos; Cano, Pedro; Korbling, Martin; Giralt, Sergio; Shpall, Elizabeth J; Wang, Xuemei; Thall, Peter F; Champlin, Richard E; Fernandez-Vina, Marcelo

    2009-10-27

    BACKGROUND.: Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSA) have been implicated in graft rejection in solid organ transplantation, their role in hematopoietic stem-cell transplantation remains unclear. METHODS.: To address the hypothesis that the presence of DSA contributes to the development graft failure, we tested 24 consecutive patients for the presence of anti-HLA antibodies determined by a sensitive and specific solid-phase/single-antigen assay. The study included a total of 28 haploidentical transplants, each with 2 to 5 HLA allele mismatches, at a single institution, from September 2005 to August 2008. RESULTS.: DSA were detected in five patients (21%). Three of four (75%) patients with DSA before the first transplant failed to engraft, compared with 1 of 20 (5%) without DSA (P=0.008). All four patients who experienced primary graft failure had second haploidentical transplants. One patient developed a second graft failure with persistent high DSA levels, whereas three engrafted, two of them in the absence of DSA. No other known factors that could negatively influence engraftment were associated with the development of graft failure in these patients. CONCLUSIONS.: These results suggest that donor-specific anti-HLA antibodies are associated with a high rate of graft rejection in patients undergoing haploidentical stem-cell transplantation. Anti-HLA sensitization should be evaluated routinely in hematopoietic stem-cell transplantation with HLA mismatched donors.

  20. Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Matoba, M.; Tonami, H.; Kuginuki, M.; Yokota, H.; Takashima, S.; Yamamoto, I.

    2003-01-01

    AIM: To evaluate the validity of high-resolution contrast-enhanced three-dimensional magnetic resonance angiography (MRA) in defining hepatic arterial anatomy and to compare this with digital subtraction angiography (DSA). MATERIALS AND METHODS: MRA and DSA were performed in 30 patients. MRA was performed with breath-hold, gadolinium-enhanced, three-dimensional, fast low-angle shot sequence with a 512 pixel matrix. MRA was compared with DSA in terms of image quality and depiction of hepatic arterial anatomy. The agreement in image quality between MRA and DSA was determined with the kappa statistic. RESULTS: With respect to image quality, there was excellent or good correlation between MRA and DSA for the common hepatic artery (κ=0.85), proper hepatic artery (κ=0.72), gastroduodenal artery (κ=0.70), left hepatic artery (κ=0.49), left gastric artery (κ=0.50), splenic artery (κ=0.84), and superior mesenteric artery (κ=0.88). Poor correlation was found for the right hepatic artery (κ=0.18) and right gastric artery (κ=0.38). With regard to hepatic arterial anatomy, MRA correlated correctly with DSA in 28 of the 29 cases, i.e. 97% of patients. CONCLUSION: MRA is a useful technique for the evaluation of the hepatic artery, and for the vast majority of patients, MRA can replace intra-arterial DSA

  1. Solar photo-Fenton mineralization of antipyrine in aqueous solution.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; Sanmartín, I; Carrasco, A

    2013-11-30

    The mineralization of an aqueous solution of antipyrine (C11H12N2O), an emerging contaminant, using a solar photocatalytic oxidation process assisted with ferrioxalate was evaluated in a compound parabolic collector (CPC) pilot plant. Under the selected operating conditions ([H2O2] = 250 ppm, [Fe] = 14 ppm, pH = 2.7, and [(COOH)2·2H2O] = 80 ppm), 60% of TOC is removed just 5 min after treating an aqueous solution containing 50 ppm of antipyrine. The addition of oxalic acid up to a maximum concentration of 80 ppm significantly increases the mineralization rate during the first 15 min of the reaction. The synergism between the solar and dark H2O2/ferrioxalate process was quantified at 79%, calculated from the pseudo first-order mineralization rate constants. The operational costs due to the consumption of electrical energy, reagents and catalysts were calculated from the optimal conditions and compared with a novel sono-photocatalytic process using artificial UV-light. The results showed that the ferrioxalate-assisted solar photo-Fenton process was economically feasible, being able to achieve up to 60% mineralization with a total cost of 4.5 cent €/g TOC removed (1.1 €/m(3)). Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. The use of socially assistive robots for dementia care.

    Science.gov (United States)

    Huschilt, Julie; Clune, Laurie

    2012-10-01

    Innovative solutions for dementia care are required to address the steady rise in adults living with dementia, lack of adequate staffing to provide high-quality dementia care, and the need for family caregivers to provide care for their loved ones in the home. This article provides an overview of the use of socially assistive robots (SARs) to offer support as therapists, companions, and educators for people living with dementia. Social, ethical, and legal challenges associated with the use of robotic technology in patient care and implications for the use of SARs by nurses are discussed. These items considered, the authors conclude that SARs should be considered as a viable way to assist people living with dementia to maintain their highest possible level of independence, enhance their quality of life, and provide support to overburdened family caregivers. Further research is needed to evaluate the merits of this technological approach in the care of adults with dementia. Copyright 2012, SLACK Incorporated.

  3. Behind every innovative solution lies an obscure feature

    Directory of Open Access Journals (Sweden)

    Lee Spector (Fellow ISGEC

    2012-06-01

    Full Text Available The Obscure Features Hypothesis (OFH for innovation states that a two-step process undergirds almost all innovative solutions: (1 notice an infrequently observed or new (i.e., obscure feature of the problem and (2 construct an interaction involving the obscure feature that produces the desired effects to solve the problem. The OFH leads to a systematic derivation of innovation-enhancing techniques by engaging in two tasks. First, we developed a 32-category system of the types of features possessable by a physical object or material. This Feature Type Taxonomy (FTT provides a panoramic view of the space of features and assists in searches for the obscure ones. Second, we are articulating the many cognitive reasons that obscure features are overlooked and are developing countering techniques for each known reason. We present the implications and techniques of the OFH, as well as indicate how software can assist innovators in the effective use of these innovation-enhancing techniques.

  4. Solution-phase synthesis of nanomaterials at low temperature

    Science.gov (United States)

    Zhu, Yongchun; Qian, Yitai

    2009-01-01

    This paper reviews the solution-phase synthesis of nanoparticles via some routes at low temperatures, such as room temperature route, wave-assisted synthesis (γ-irradiation route and sonochemical route), directly heating at low temperatures, and hydrothermal/solvothermal methods. A number of strategies were developed to control the shape, the size, as well as the dispersion of nanostructures. Using diethylamine or n-butylamine as solvent, semiconductor nanorods were yielded. By the hydrothermal treatment of amorphous colloids, Bi2S3 nanorods and Se nanowires were obtained. CdS nanowires were prepared in the presence of polyacrylamide. ZnS nanowires were obtained using liquid crystal. The polymer poly (vinyl acetate) tubule acted as both nanoreactor and template for the CdSe nanowire growth. Assisted by the surfactant of sodium dodecyl benzenesulfonate (SDBS), nickel nanobelts were synthesized. In addition, Ag nanowires, Te nanotubes and ZnO nanorod arrays could be prepared without adding any additives or templates.

  5. Applied Operations Research: Operator's Assistant

    Science.gov (United States)

    Cole, Stuart K.

    2015-01-01

    NASA operates high value critical equipment (HVCE) that requires trouble shooting, periodic maintenance and continued monitoring by Operations staff. The complexity HVCE and information required to maintain and trouble shoot HVCE to assure continued mission success as paper is voluminous. Training on new HVCE is commensurate with the need for equipment maintenance. LaRC Research Directorate has undertaken a proactive research to support Operations staff by initiation of the development and prototyping an electronic computer based portable maintenance aid (Operator's Assistant). This research established a goal with multiple objectives and a working prototype was developed. The research identified affordable solutions; constraints; demonstrated use of commercial off the shelf software; use of the US Coast Guard maintenance solution; NASA Procedure Representation Language; and the identification of computer system strategies; where these demonstrations and capabilities support the Operator, and maintenance. The results revealed validation against measures of effectiveness and overall proved a substantial training and capability sustainment tool. The research indicated that the OA could be deployed operationally at the LaRC Compressor Station with an expectation of satisfactorily results and to obtain additional lessons learned prior to deployment at other LaRC Research Directorate Facilities. The research revealed projected cost and time savings.

  6. FEMA Hazard Mitigation Assistance Flood Mitigation Assistance (FMA) Data

    Data.gov (United States)

    Department of Homeland Security — This dataset contains closed and obligated projects funded under the following Hazard Mitigation Assistance (HMA) grant programs: Flood Mitigation Assistance (FMA)....

  7. Development of brake assist system. Summary of hydraulic brake assist system; Brake assist system no kaihatsu. Ekiatsushiki brake assist system no gaiyo

    Energy Technology Data Exchange (ETDEWEB)

    Hara, M; Ota, M; Shimizu, S [Toyota, Motor Corp., Aichi (Japan)

    1997-10-01

    We have already developed vacuum-booster-type Brake Assist System that supplies additional braking power when panic braking is recognized. We are convinced that the expansion of Brake Assist System will become more important issue in the future. Therefore we have developed hydraulic Brake Assist System with increasing its controllability and reducing its discomfort. This system have a brake pressure sensor to detect emergency braking operation and an antilock device to supply additional braking power. 8 refs., 11 figs.

  8. The lithographer's dilemma: shrinking without breaking the bank

    Science.gov (United States)

    Levinson, Harry J.

    2013-10-01

    It can no longer be assumed that the lithographic scaling which has previously driven Moore's Law will lead in the future to reduced cost per transistor. Until recently, higher prices for lithography tools were offset by improvements in scanner productivity. The necessity of using double patterning to extend scaling beyond the single exposure resolution limit of optical lithography has resulted in a sharp increase in the cost of patterning a critical construction layer that has not been offset by improvements in exposure tool productivity. Double patterning has also substantially increased the cost of mask sets. EUV lithography represents a single patterning option, but the combination of very high exposure tools prices, moderate throughput, high maintenance costs, and expensive mask blanks makes this a solution more expensive than optical double patterning but less expensive than triple patterning. Directed self-assembly (DSA) could potentially improve wafer costs, but this technology currently is immature. There are also design layout and process integration issues associated with DSA that need to be solved in order to obtain full benefit from tighter pitches. There are many approaches for improving the cost effectiveness of lithography. Innovative double patterning schemes lead to smaller die. EUV lithography productivity can be improved with higher power light sources and improved reliability. There are many technical and business challenges for extending EUV lithography to higher numerical apertures. Efficient contact hole and cut mask solutions are needed, as well as very tight overlay control, regardless of lithographic solution.

  9. Exceptionally crystalline and conducting acid doped polyaniline films by level surface assisted solution casting approach

    Energy Technology Data Exchange (ETDEWEB)

    Puthirath, Anand B.; Varma, Sreekanth J.; Jayalekshmi, S., E-mail: jayalekshmi@cusat.ac.in [Division for Research in Advanced Materials, Department of Physics, Cochin University of Science and Technology, Cochin, Kerala 682022 (India); Methattel Raman, Shijeesh [Nanophotonic and Optoelectronic Devices Laboratory, Department of Physics, Cochin University of Science and Technology, Cochin, Kerala 682022 (India)

    2016-04-18

    Emeraldine salt form of polyaniline (PANI) was synthesized by chemical oxidative polymerisation method using ammonium persulfate as oxidant. Resultant emeraldine salt form of PANI was dedoped using ammonia solution and then re-doped with camphor sulphonic acid (CSA), naphthaline sulphonic acid (NSA), hydrochloric acid (HCl), and m-cresol. Thin films of these doped PANI samples were deposited on glass substrates using solution casting method with m-cresol as solvent. A level surface was employed to get homogeneous thin films of uniform thickness. Detailed X-ray diffraction studies have shown that the films are exceptionally crystalline. The crystalline peaks observed in the XRD spectra can be indexed to simple monoclinic structure. FTIR and Raman spectroscopy studies provide convincing explanation for the exceptional crystallinity observed in these polymer films. FESEM and AFM images give better details of surface morphology of doped PANI films. The DC electrical conductivity of the samples was measured using four point probe technique. It is seen that the samples also exhibit quite high DC electrical conductivity, about 287 S/cm for CSA doped PANI, 67 S/cm for NSA doped PANI 65 S/cm for HCl doped PANI, and just below 1 S/cm for m-cresol doped PANI. Effect of using the level surface for solution casting is studied and correlated with the observed crystallinity.

  10. Microwave-assisted clean synthesis of amides via aza-wittig reaction under solvent-free condition

    Energy Technology Data Exchange (ETDEWEB)

    Sathishkumar, Murugan; Nagarajan, Sangaraiah; Velan, Poovan Shanmuga; Dinesh, Murugan; Ponnuswamy, Alagusundaram [Department of Organic Chemistry, School of Chemistry, Madurai Kamaraj University, Tamilnadu (India)

    2011-09-15

    A solvent-free microwave-assisted coupling of phosphazenes with acyl chlorides or carboxylic anhydrides in presence of triethylphosphite has been accomplished resulting in a clean synthesis of amides in good yields. Unlike the prevailing time-consuming solution phase methodologies employing chlorinated solvents, benzene (carcinogenic), etc, the present protocol is an eco friendly, rapid and simple approach. (author)

  11. Ten Years Back, Five Years Forward: The Data Seal of Approval

    Directory of Open Access Journals (Sweden)

    Ingrid Dillo

    2015-02-01

    Full Text Available If we want to share data, the long-term storage of those data in a trustworthy digital archive is an essential condition. Trust is the basis of storing and sharing data. That trust must be present in the various stakeholders involved. Certification of digital archives can make an important contribution to the confidence of these stakeholders in the digital archives.Ten years ago DANS was assigned the task of developing a Seal of Approval for digital data to ensure that archived data can still be found, understood and used in the future. In 2009 this Data Seal of Approval (DSA was transferred to an international body, the DSA Board, which has managed and further developed the guidelines and the peer review process ever since.The objectives of the DSA are to safeguard data, ensure high quality and guide reliable management of data for the future without requiring implementation of new standards, regulations or heavy investments. The DSA contains 16 guidelines for applying and verifying quality aspects concerning the creation, storage, use and reuse of digital data.Based on feedback from data archives that applied for a DSA and different case studies we have gained some insight into the benefits of DSA. Still, the impact of having the Seal is not easy to measure. Seal holders usually refer to qualitative benefits in the form of increased awareness of the value of their repositories to their communities, funders and publishers.Ten years down the line we can safely state that the Data Seal of Approval has proven its added value. If we try to look five years into the future, what can we expect? There are different developments: a growing interest in DSA among European research infrastructures, the collaboration between DSA and the ISCU World Data System under the umbrella of the RDA (Research Data Alliance and the European Commission is showing a growing interest in certification services.The success of DSA also provides the challenge to further

  12. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  13. Detection of the origin of the cystic artery during transcatheter arterial embolization of hepatocellular carcinomas. Comparison of cone beam CT and digital subtraction angiography

    International Nuclear Information System (INIS)

    Hashizume, Takashi; Honda, Minoru; Seino, Noritaka; Gokan, Takehiko; Hashimoto, Toshi

    2009-01-01

    In this study, we retrospectively compared the usefulness of cone beam CT (CBCT) with that of digital subtraction angiography (DSA) in the identification of the origin of the cystic artery during arterial embolization for hepatocellular carcinoma. Subjects were sixty-four patients who underwent transcatheter arterial embolization (TAE) for hepatocellular carcinoma, in whom both CBCT and DSA were performed. Two radiologists independently examined CBCT and DSA images, and attempted to identify the origin of the cystic artery in each image. For DSA, en face views were reviewed on the monitor. For CBCT, 5 mm thick horizontal sections were generated using Workstation software, and the MPR (multi-planner reconstruction) method was used for coronary sections. These were then investigated with OsiriX. Of the sixty-four patients, the cystic arterial origin could be identified using DSA in 21 (32.8%) and CBCT in 62 (96.8%). The cystic artery was shown to originate in the proper, right, middle, and left hepatic artery in one, 58, two, and one patient, respectively. These results show that CBCT was more useful than DSA for identifying cystic arterial origin. Therefore CBCT should be positively applied during TAE. (author)

  14. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    International Nuclear Information System (INIS)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.)

  15. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  16. Predictive value of digital subtraction angiography in patients with tuberculous meningitis

    International Nuclear Information System (INIS)

    Rojas-Echeverri, L.A.; Soto-Hernandez, J.L.; Garza, S.; Martinez-Zubieta, R.; Miranda, L.I.; Garcia-Ramos, G.; Zenteno, M.

    1996-01-01

    Digital subtraction angiography (DSA) was performed in 24 adults with tuberculous meningitis (TBM) and results were correlated with 24 admission and 16 follow-up CT examinations. 19 MRI studies and clinical outcome at a mean follow-up of 44 weeks. DSA was abnormal in 11 patients. Abnormal DSA was associated with advenced clinical stages of the Medical Research Council classification, admission CT with hydrocephalus or gyral cortical enhancement. MRI disclosed brain infarcts not seen on initial CT in 8 cases. Of seven patients who died, 4 had abnormal and 3 normal DSA. Among patients who survived, those with normal DSA had a better functional outcome by Karnofsky scores. During follow-up infarcts were evident in 16 patients. Abnormal DSA in relation to brain infarcts had a sensitivity of 0.56, specificity 0.75, positive predictive value 0.82 and negative predictive value 0.46. A single arteriogram does not predict the outcome in patients with TBM and its value is limited in the assessment of vascular complications of TBM. Angiography in TBM is justified only in specific clinical trials to assess new therapeutic modalities against infarcts. (orig.)

  17. Chemical solution deposition of YBCO thin film by different polymer additives

    International Nuclear Information System (INIS)

    Wang, W.T.; Li, G.; Pu, M.H.; Sun, R.P.; Zhou, H.M.; Zhang, Y.; Zhang, H.; Yang, Y.; Cheng, C.H.; Zhao, Y.

    2008-01-01

    A polymer-assisted chemical solution deposition approach has been proposed for the preparation of YBCO thin film. Different additives like PVB (polyvinyl butyral), PEG (polyethylene glycol) and PVP (polyvinylpyrrolidone) have been used to adjust the final viscosity of the precursor solution and thus the film formation. In this fluorine-free approach, YBCO has been deposited on single crystal substrates with metal acetates being starting materials. Biaxially textured YBCO thin films have been obtained. However, different additives lead to different microstructure. Dense, smooth and crack-free YBCO film prepared with PVB as additive yields sharp superconducting transition around T c = 90 K as well as high J c (0 T, 77 K) over 3 MA/cm 2

  18. Chemical solution deposition of YBCO thin film by different polymer additives

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W.T.; Li, G.; Pu, M.H.; Sun, R.P.; Zhou, H.M.; Zhang, Y. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains, Ministry of Education of China, Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); Zhang, H. [Department of Physics, Peking University, Beijing 100871 (China); Yang, Y. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains, Ministry of Education of China, Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); Cheng, C.H. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains, Ministry of Education of China, Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); School of Materials Science and Engineering, University of New South Wale, Sydney, 2052 NSW (Australia); Zhao, Y. [Key Laboratory of Magnetic Levitation Technologies and Maglev Trains, Ministry of Education of China, Superconductivity R and D Center (SRDC), Mail Stop 165, Southwest Jiaotong University, Chengdu 610031 (China); School of Materials Science and Engineering, University of New South Wale, Sydney, 2052 NSW (Australia)], E-mail: yzhao@swjtu.edu.cn

    2008-09-15

    A polymer-assisted chemical solution deposition approach has been proposed for the preparation of YBCO thin film. Different additives like PVB (polyvinyl butyral), PEG (polyethylene glycol) and PVP (polyvinylpyrrolidone) have been used to adjust the final viscosity of the precursor solution and thus the film formation. In this fluorine-free approach, YBCO has been deposited on single crystal substrates with metal acetates being starting materials. Biaxially textured YBCO thin films have been obtained. However, different additives lead to different microstructure. Dense, smooth and crack-free YBCO film prepared with PVB as additive yields sharp superconducting transition around T{sub c} = 90 K as well as high J{sub c} (0 T, 77 K) over 3 MA/cm{sup 2}.

  19. Computer-assisted learning and simulation systems in dentistry--a challenge to society.

    Science.gov (United States)

    Welk, A; Splieth, Ch; Wierinck, E; Gilpatrick, R O; Meyer, G

    2006-07-01

    Computer technology is increasingly used in practical training at universities. However, in spite of their potential, computer-assisted learning (CAL) and computer-assisted simulation (CAS) systems still appear to be underutilized in dental education. Advantages, challenges, problems, and solutions of computer-assisted learning and simulation in dentistry are discussed by means of MEDLINE, open Internet platform searches, and key results of a study among German dental schools. The advantages of computer-assisted learning are seen for example in self-paced and self-directed learning and increased motivation. It is useful for both objective theoretical and practical tests and for training students to handle complex cases. CAL can lead to more structured learning and can support training in evidence-based decision-making. The reasons for the still relatively rare implementation of CAL/CAS systems in dental education include an inability to finance, lack of studies of CAL/CAS, and too much effort required to integrate CAL/CAS systems into the curriculum. To overcome the reasons for the relative low degree of computer technology use, we should strive for multicenter research and development projects monitored by the appropriate national and international scientific societies, so that the potential of computer technology can be fully realized in graduate, postgraduate, and continuing dental education.

  20. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  1. Assistive Technology

    Science.gov (United States)

    ... Page Resize Text Printer Friendly Online Chat Assistive Technology Assistive technology (AT) is any service or tool that helps ... be difficult or impossible. For older adults, such technology may be a walker to improve mobility or ...

  2. GAAP: Genome-organization-framework-Assisted Assembly Pipeline for prokaryotic genomes.

    Science.gov (United States)

    Yuan, Lina; Yu, Yang; Zhu, Yanmin; Li, Yulai; Li, Changqing; Li, Rujiao; Ma, Qin; Siu, Gilman Kit-Hang; Yu, Jun; Jiang, Taijiao; Xiao, Jingfa; Kang, Yu

    2017-01-25

    Next-generation sequencing (NGS) technologies have greatly promoted the genomic study of prokaryotes. However, highly fragmented assemblies due to short reads from NGS are still a limiting factor in gaining insights into the genome biology. Reference-assisted tools are promising in genome assembly, but tend to result in false assembly when the assigned reference has extensive rearrangements. Herein, we present GAAP, a genome assembly pipeline for scaffolding based on core-gene-defined Genome Organizational Framework (cGOF) described in our previous study. Instead of assigning references, we use the multiple-reference-derived cGOFs as indexes to assist in order and orientation of the scaffolds and build a skeleton structure, and then use read pairs to extend scaffolds, called local scaffolding, and distinguish between true and chimeric adjacencies in the scaffolds. In our performance tests using both empirical and simulated data of 15 genomes in six species with diverse genome size, complexity, and all three categories of cGOFs, GAAP outcompetes or achieves comparable results when compared to three other reference-assisted programs, AlignGraph, Ragout and MeDuSa. GAAP uses both cGOF and pair-end reads to create assemblies in genomic scale, and performs better than the currently available reference-assisted assembly tools as it recovers more assemblies and makes fewer false locations, especially for species with extensive rearranged genomes. Our method is a promising solution for reconstruction of genome sequence from short reads of NGS.

  3. Providing Assistive Technology Applications as a Service Through Cloud Computing.

    Science.gov (United States)

    Mulfari, Davide; Celesti, Antonio; Villari, Massimo; Puliafito, Antonio

    2015-01-01

    Users with disabilities interact with Personal Computers (PCs) using Assistive Technology (AT) software solutions. Such applications run on a PC that a person with a disability commonly uses. However the configuration of AT applications is not trivial at all, especially whenever the user needs to work on a PC that does not allow him/her to rely on his / her AT tools (e.g., at work, at university, in an Internet point). In this paper, we discuss how cloud computing provides a valid technological solution to enhance such a scenario.With the emergence of cloud computing, many applications are executed on top of virtual machines (VMs). Virtualization allows us to achieve a software implementation of a real computer able to execute a standard operating system and any kind of application. In this paper we propose to build personalized VMs running AT programs and settings. By using the remote desktop technology, our solution enables users to control their customized virtual desktop environment by means of an HTML5-based web interface running on any computer equipped with a browser, whenever they are.

  4. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  5. Non-governmental organizations assisting victims of crime in Belgrade: Survey results

    Directory of Open Access Journals (Sweden)

    Milivojević Sanja K.

    2003-01-01

    Full Text Available This paper presents the results of survey regarding non-governmental organizations assisting victims of crime in Belgrade. The survey was completed at the end of 2002 for purposes of establishing a Victim Support Service in Serbia. In introduction authors give a short review of victim support services development in the World and the region, explaining the need for such service in Serbia, the subject and the aim of the article as well as the purpose of the survey. Second part of the paper contains the sample, methodology and the aim of the interview with NGO representatives. In the third section authors present the analysis of the survey data. Finally, in conclusion authors summarize the data and observed problems, suggestions for possible solution and directions of future development of services and organizations assisting victims of crime in Serbia.

  6. Ambient Assisted Living and ageing: preliminary results of RITA project.

    Science.gov (United States)

    Aquilano, Michela; Cavallo, Filippo; Bonaccorsi, Manuele; Esposito, Raffaele; Rovini, Erika; Filippi, Massimo; Esposito, Dario; Dario, Paolo; Carrozza, Maria Chiara

    2012-01-01

    The ageing of population is a social phenomenon that most of worldwide countries are facing. They are, and will be even more in the future, indeed trying to find solutions for improving quality of life of their elderly citizens. The project RITA wants to demonstrate that an update of the current socio-medical services with an Ambient Assisted Living (AAL) approach could improve the service efficiency and the quality of life of both elderly and caregiver. This paper presents the preliminary results obtained in RITA.

  7. Unilateral and bilateral internal carotid artery stenosis or occlusion: a study of the secondary collateral circulation

    International Nuclear Information System (INIS)

    Zhao Yunhui; Ma Zhubin; Zhuang Lei; Liu Jianjun; Zang Jianhua

    2006-01-01

    Objective: It's a study of the collateral circulation secondary to unilateral and bilateral internal carotid artery (ICA) severe stenosis or occlusion using digital subtract angiography (DSA) and magnetic resonance angiography (MRA). Methods: Ninty-five patients with ICA stenosis or occlusion were diagnosed by DSA or MRA. Forty-four patients were assessed by DSA, and fifty-one patients were evaluated by MRA, who were divided into two groups of the unilateral and bilateral involvement. DSA, MRA findings were analyzed, by which the patterns of the collateral circulation were comparatively studied. Results: The presence rate of anterior communicating artery (AcoA) in the unilateral group on DSA and MRA was significantly higher than that in the bilateral group (P 0.05). On DSA, the presence rate of ophthalmic artery (OphA) in the unilateral and bilateral groups had no significant difference between the two groups. The augmentation rate of the OphA in the bilateral group was significantly higher than that in the unilateral group (P<0.05). The presence rate of leptomeningeal anastomosis in the bilateral group was significantly higher than that in the unilateral group on DSA and MRA (P<0.01). Conclusion: In patients with the unilateral and bilateral ICA stenosis or occlusion, the collateral circulation formats in different patterns. The major collateral pathways secondary to the unilateral ICA stenosis or occlusion are AcoA and ispilateral PCoA, while to the bilateral ICA stenosis or' occlusion are PCoA, OPhA, and leptomeningeal anastomosis. (authors)

  8. Perioperative Desensitization Improves Outcomes Among Crossmatch Positive Recipients of Deceased Donor Renal Transplants.

    Science.gov (United States)

    Sharma, Amit; King, Anne; Kumar, Dhiren; Behnke, Martha; McDougan, Felecia; Kimball, Pamela M

    2016-06-01

    Graft failure due to chronic rejection is greater among renal transplant patients with donor-specific antibody (DSA) than among DSA-free patients. For patients dependent on deceased donor transplantation, preoperative desensitization to eliminate DSAs may be impractical. We speculated that perioperative desensitization might eliminate preexisting DSAs and prevent de novo DSAs and improve graft outcomes. We report that brief perioperative desensitization using either intravenous immunoglobulin (IVIG) or plasmapheresis/IVIG (PP/IVIG) treatment improves clinical outcomes among patients with positive crossmatches. Immediately following deceased donor transplantation, 235 renal recipients were assigned points for PRA and flow crossmatches (FCXM): delayed graft function (DGF) ≤ 1 point received standard therapy; 2 points received high-dose IVIG; and ≥3 points received PP/IVIG. The DSAs were serially monitored by single antigen bead luminex for 1 year. Five-year clinical outcomes were determined from the chart review. All desensitized patients had preoperatively positive FCXM with DSA. Rejection was more common (P desensitized than nonsensitized groups. However, overall graft survivals were similar between the groups (P = not significant) and superior to historic untreated patients (P 90% in all desensitizated patients with DSA elimination as well as PP/IVIG patients with residual DSA. In contrast, IVIG patients with persistent DSA had poorer graft survival (45%, P desensitization improved overall graft survival of sensitized patients compared to historic untreated patients. Plasmapheresis/IVIG had greater impact on DSA eradication and graft survival than IVIG alone. © 2016, NATCO.

  9. A kriging metamodel-assisted robust optimization method based on a reverse model

    Science.gov (United States)

    Zhou, Hui; Zhou, Qi; Liu, Congwei; Zhou, Taotao

    2018-02-01

    The goal of robust optimization methods is to obtain a solution that is both optimum and relatively insensitive to uncertainty factors. Most existing robust optimization approaches use outer-inner nested optimization structures where a large amount of computational effort is required because the robustness of each candidate solution delivered from the outer level should be evaluated in the inner level. In this article, a kriging metamodel-assisted robust optimization method based on a reverse model (K-RMRO) is first proposed, in which the nested optimization structure is reduced into a single-loop optimization structure to ease the computational burden. Ignoring the interpolation uncertainties from kriging, K-RMRO may yield non-robust optima. Hence, an improved kriging-assisted robust optimization method based on a reverse model (IK-RMRO) is presented to take the interpolation uncertainty of kriging metamodel into consideration. In IK-RMRO, an objective switching criterion is introduced to determine whether the inner level robust optimization or the kriging metamodel replacement should be used to evaluate the robustness of design alternatives. The proposed criterion is developed according to whether or not the robust status of the individual can be changed because of the interpolation uncertainties from the kriging metamodel. Numerical and engineering cases are used to demonstrate the applicability and efficiency of the proposed approach.

  10. Bus driving assistance system for town area by using ATmega328P microcontroller

    Science.gov (United States)

    Zakaria, Mohamad Fauzi; Soon, Tan Jiah; Rohani, Munzilah Md

    2017-09-01

    Recently, several bus accidents happened because of bus driver's behavior. In fact, there is no dedicated tool for assisting them to drive safely. This project gives solutions to this by assisting the driver, according to the speed and acceleration of the bus. These data are collected by using a motion processing unit (MPU-6050) and a global positioning system (GPS) and then indicate the driving mode status on the LEDs. All data and status are recorded in a secure digital (SD) card for the authority or the bus company to analyze the driving behavior of a bus driver. This system has been successfully developed and tested in two different areas which includes the UTHM main campus and the road from Parit Raja to Batu Pahat.

  11. Model assisted multiobjective optimization with {lambda}-control; Multikriterielle Optimierung mit {lambda}-geregelten modellgestuetzten Evolutionsstrategien

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Jan; Hoffmann, Frank; Krettek, Johannes; Bertram, Torsten [Technische Univ. Dortmund (Germany). Lehrstuhl RST

    2009-07-01

    Evolutionary algorithms require a large number of fitness evaluations in order to find an optimal solution. This property limits their application to hardware in the loop optimization or optimization of time-consuming simulations and calculations. This contribution proposes a preselection with data based models in order to reduce the number of true fitness evaluations. It extends previous approaches for model assisted scalar optimization to multiobjective problems by a proper redefinition of model quality and ?-control. The application to multiobjective benchmark optimization problems underlies the improved convergence of the model assisted evolution strategy compared to a multiobjective evolution strategy as well as the advantages of a {lambda}-controlled variant compared to a static preselection. (orig.)

  12. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Gmelin, E.; Arlart, I.P.

    1987-01-01

    The introduction explains the technical and physical fundamentals of digital radiography, the principles of digital subtraction, and the various filtering methods. The authors then define the requirements to be met by a DSA equipment in terms of technical components and operational performance. A very extensive chapter deals with the indications supporting intravenous or intraarterial DSA and compares the two methods, showing advantages and drawbacks with respect to practical results. Another chapter discusses the applications of DSA for cardiological diagnostics, as e.g. imaging of the coronary arteries or arterial bypasses, and explains the densitometric and planimetric evaluation of the coronary functional processes. The book also discusses less customary applications of DSA such as the sialography or dacryocystography, as well as angiologic examinations in children. The limits of the DSA methods are discussed in the last chapter, together with aspects such as the radiation exposure of the patient, and cost-benefit analyses, and potential future improvements. With 204 figs., 44 tabs [de

  13. Headache-like Subarachnoid Hemorrhage After Digital Subtraction Angiography: A Case Report

    Directory of Open Access Journals (Sweden)

    Fettah Eren

    2018-03-01

    Full Text Available Subarachnoid hemorrhage (SAH is a clinical condition with acute-onset, sudden, and severe headache. In addition to headache, severe nausea, vomiting, dizziness, confusion, agitation, focal neurologic deficits, and hypertension can be detected. Findings of meningeal irritation may accompany to these clinical features, 6-24 hours after the hemorrhage. Digital subtraction angiography (DSA is used for surgical or endovascular treatment planning in order to identify vascular abnormalities, in addition to other imaging studies. After DSA, the frequency of all neurologic complications is between 0.2% and 4.5%. Headache may occur after DSA in an average 50% of patients. This rate is especially higher in female patients. Headache types are usually classified as migraine, tension or postoperative atypical headaches The incidence of severe headache after DSA is low. Vascular wall rupture should be considered first in severe headache after the procedure. It should also be kept in mind that after all other secondary causes are excluded; SAH-like headaches after DSA can be detected

  14. Internal friction studies on dynamic strain aging in P91 ferritic steel

    International Nuclear Information System (INIS)

    Zhou, Hongwei; Fang, Junfei; Chen, Yan; Yang, Lei; Zhang, Hui; Lu, Yun; He, Yizhu

    2016-01-01

    The temperature of dynamic strain aging (DSA) regime in P91 steel is between 523 K and 773 K. The activation energy (Q) for onset of DSA is 73 kJ/mol, while that for finale of DSA is 202 kJ/mol. Two main Internal friction (IF) speaks were observed, Snoek and SKK with the activation energy of 67.9 kJ/mol and 121 kJ/mol, respectively. IF shows that activation energy of 73 kJ/mol is equal to that of C atom body diffusion in α-Fe, and 202 kJ/mol is equal to binding energy between C atoms and moving dislocations. These results confirm that the mechanism of DSA can be explained by the diffusion of C atoms and pinning between C and moving dislocation. These investigations indicate that DSA in P91 steel is resulted from C atom diffusion, instead of Cr or Mo atoms.

  15. Microwave-assisted synthesis of iron oxide nanoparticles in biocompatible organic environment

    Directory of Open Access Journals (Sweden)

    E. Aivazoglou

    2018-04-01

    Full Text Available The development of magnetite and maghemite particles in uniform nanometer size has triggered the interest of the research community due to their many interesting properties leading to a wide range of applications, such as catalysis, nanomedicine-nanobiology and other engineering applications. In this study, a simple, time-saving and low energy-consuming, microwave-assisted synthesis of iron oxide nanoparticles, is presented. The nanoparticles were prepared by microwave-assisted synthesis using polyethylene glycol (PEG or PEG and β-cyclodextrin (β-CD/water solutions of chloride salts of iron in the presence of ammonia solution. The prepared nano-powders were characterized using X-Ray Diffraction (XRD, Transition Electron Microscopy (TEM, Fourier-transform Infrared Spectroscopy (FTIR, Raman Spectroscopy, Vibrating Sample Magnetometer (VSM, X-Ray Photoelectron Spectroscopy (XPS and Thermal analysis (TG/DSC. The produced nanoparticles are crystallized mostly in the magnetite and maghemite lattice exhibiting very similar shape and size, with indications of partial PEG coating. Heating time, microwave power and presence of PEG, are the key factors shaping the size properties of nanoparticles. The average size of particles ranges from 10.3 to 19.2 nm. The nanoparticles exhibit a faceted morphology, with zero contamination levels. The magnetic measurements indicate that the powders are soft magnetic materials with negligible coercivity and remanence, illustrating super-paramagnetic behavior.

  16. Robot assistant versus human or another robot assistant in patients undergoing laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Samraj, Kumarakrishnan; Fusai, Giuseppe; Davidson, Brian R

    2012-09-12

    The role of a robotic assistant in laparoscopic cholecystectomy is controversial. While some trials have shown distinct advantages of a robotic assistant over a human assistant others have not, and it is unclear which robotic assistant is best. The aims of this review are to assess the benefits and harms of a robot assistant versus human assistant or versus another robot assistant in laparoscopic cholecystectomy, and to assess whether the robot can substitute the human assistant. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded (until February 2012) for identifying the randomised clinical trials. Only randomised clinical trials (irrespective of language, blinding, or publication status) comparing robot assistants versus human assistants in laparoscopic cholecystectomy were considered for the review. Randomised clinical trials comparing different types of robot assistants were also considered for the review. Two authors independently identified the trials for inclusion and independently extracted the data. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence interval (CI) using the fixed-effect and the random-effects models based on intention-to-treat analysis, when possible, using Review Manager 5. We included six trials with 560 patients. One trial involving 129 patients did not state the number of patients randomised to the two groups. In the remaining five trials 431 patients were randomised, 212 to the robot assistant group and 219 to the human assistant group. All the trials were at high risk of bias. Mortality and morbidity were reported in only one trial with 40 patients. There was no mortality or morbidity in either group. Mortality and morbidity were not reported in the remaining trials. Quality of life or the proportion of patients who were discharged as day-patient laparoscopic cholecystectomy patients were not reported in any

  17. Diffusive Shock Acceleration and Turbulent Reconnection

    Science.gov (United States)

    Garrel, Christian; Vlahos, Loukas; Isliker, Heinz; Pisokas, Theophilos

    2018-05-01

    Diffusive Shock Acceleration (DSA) cannot efficiently accelerate particles without the presence of self-consistently generated or pre-existing strong turbulence (δB/B ˜ 1) in the vicinity of the shock. The problem we address in this article is: if large amplitude magnetic disturbances are present upstream and downstream of a shock then Turbulent Reconnection (TR) will set in and will participate not only in the elastic scattering of particles but also in their heating and acceleration. We demonstrate that large amplitude magnetic disturbances and Unstable Current Sheets (UCS), spontaneously formed in the strong turbulence in the vicinity of a shock, can accelerate particles as efficiently as DSA in large scale systems and on long time scales. We start our analysis with "elastic" scatterers upstream and downstream and estimate the energy distribution of particles escaping from the shock, recovering the well known results from the DSA theory. Next we analyze the additional interaction of the particles with active scatterers (magnetic disturbances and UCS) upstream and downstream of the shock. We show that the asymptotic energy distribution of the particles accelerated by DSA/TR has very similar characteristics with the one due to DSA alone, but the synergy of DSA with TR is much more efficient: The acceleration time is an order of magnitude shorter and the maximum energy reached two orders of magnitude higher. We claim that DSA is the dominant acceleration mechanism in a short period before TR is established, and then strong turbulence will dominate the heating and acceleration of the particles. In other words, the shock serves as the mechanism to set up a strongly turbulent environment, in which the acceleration mechanism will ultimately be the synergy of DSA and TR.

  18. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  19. 2012 annual literature review of donor-specific HLA antibodies after organ transplantation.

    Science.gov (United States)

    Kaneku, Hugo

    2012-01-01

    From the articles reviewed in the present chapter, we observed: 1. The frequency of de novo donor-specific human leukocyte antigen (HLA) antibodies (DSA) detection in different organs is very similar: ranging between 15% and 23% in kidney, 23% in pancreas, and 18% in intestinal transplant patients. Apparently, all organs can elicit humoral responses after transplantation at comparable rates. 2. Although rates of de novo DSA formation after kidney transplantation are very similar across different centers--between 15% and 23%--, the mean time to the first detection of de novo DSA is markedly variable between centers (from 8 months to 4 years). Some differences found in the studies that may account for this could be the age of patients (studies including pediatric patients tend to show longer time to DSA detection compared to studies only including adults patients), patients' race, and maintenance immunosuppression regimens. 3. In most organs, alloantibodies against class II HLA--and especially against HLA-DQ antigens--are the most common DSA detected. This finding supports previous studies, but the explanation remains unclear. Poor HLA-DQ matching, paucity of class II HLA antigen expression on cell surface, and technical factors related to the detection of these antibodies (mean fluorescence intensity cutoff, multiple beads with the same antigen, denatured protein on single antigen beads) are some of the potential explanations that need further investigation. 4. Recent focus on histological changes during rejection in the presence of DSA that are independent of C4d deposition may change how antibody-mediated rejection is diagnosed in the near future. 5. More studies are looking into the importance of DSA in non-kidney transplants and now evidence shows that DSA may not only affect survival and rejection rates, but may also be associated with organ-specific lesions like fibrosis and biliary complications in livers or capillaritis in lungs.

  20. Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger Egbert; Lin, MingDe; Duran, Rafael; Chapiro, Julius; Wang, Zhijun; Geschwind, Jean-François

    2015-01-01

    PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE