Sample records for solute leakage technique

  1. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  2. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  3. PERFORMANCE OF LEAKAGE POWER MINIMIZATION TECHNIQUE FOR CMOS VLSI TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    T. Tharaneeswaran

    2012-06-01

    Full Text Available Leakage power of CMOS VLSI Technology is a great concern. To reduce leakage power in CMOS circuits, a Leakage Power Minimiza-tion Technique (LPMT is implemented in this paper. Leakage cur-rents are monitored and compared. The Comparator kicks the charge pump to give body voltage (Vbody. Simulations of these circuits are done using TSMC 0.35µm technology with various operating temper-atures. Current steering Digital-to-Analog Converter (CSDAC is used as test core to validate the idea. The Test core (eg.8-bit CSDAC had power consumption of 347.63 mW. LPMT circuit alone consumes power of 6.3405 mW. This technique results in reduction of leakage power of 8-bit CSDAC by 5.51mW and increases the reliability of test core. Mentor Graphics ELDO and EZ-wave are used for simulations.

  4. Leakage Reduction in Water Distribution Systems with Efficient Placement and Control of Pressure Reducing Valves Using Soft Computing Techniques

    Directory of Open Access Journals (Sweden)

    A. Gupta

    2017-04-01

    Full Text Available Reduction of leakages in a water distribution system (WDS is one of the major concerns of water industries. Leakages depend on pressure, hence installing pressure reducing valves (PRVs in the water network is a successful techniques for reducing leakages. Determining the number of valves, their locations, and optimal control setting are the challenges faced. This paper presents a new algorithm-based rule for determining the location of valves in a WDS having a variable demand pattern, which results in more favorable optimization of PRV localization than that caused by previous techniques. A multiobjective genetic algorithm (NSGA-II was used to determine the optimized control value of PRVs and to minimize the leakage rate in the WDS. Minimum required pressure was maintained at all nodes to avoid pressure deficiency at any node. Proposed methodology is applied in a benchmark WDS and after using PRVs, the average leakage rate was reduced by 6.05 l/s (20.64%, which is more favorable than the rate obtained with the existing techniques used for leakage control in the WDS. Compared with earlier studies, a lower number of PRVs was required for optimization, thus the proposed algorithm tends to provide a more cost-effective solution. In conclusion, the proposed algorithm leads to more favorable optimized localization and control of PRV with improved leakage reduction rate.

  5. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  6. Developement of leakage localization technique by using acoustic signal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Jeon, J. H.; Seo, D. H.; Kim, K. W. [KAIST, Daejeon (Korea, Republic of)

    2010-07-15

    The objective of this research is to develop a leakage monitoring system for pipelines or valves in the secondary water system of a nuclear power plant. The system aims to detect the existence of leakage and to estimate the leak location, especially by utilizing the noise generated from the leak. It is safe, precise real-time alert system compared with the previous monitoring methods and tools such as the visual test and the thermal imaging camera. When there exists leakage in the pipeline or valves of nuclear power plant, the noise due to gas flow is radiated through leak region. That is, the secondary water system with leakage generates different noise from the system without leakage. This motivates us to measure and analyze the noise generated from the secondary water system, so as firstly to detect the existence of leakage, and secondly to estimate the leak location by using the noise source identification technique such as beamforming and acoustic holography. Especially the beamforming method models the signal from the noise source to estimate the location of source. Therefore, it is necessary to model the noise due to leakage which is dependent upon parameters. In the process of leak localization, the reflected wave due to interior walls and the measurement noise should be removed for the precise estimation. Therefore, we attempt to characterize the reflected wave and the measurement noise by modeling the interior sound field, thus to remove them and to localize the leak location with high precision

  7. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  8. First principle leakage current reduction technique for CMOS devices

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-12-01

    Full Text Available This paper presents a comprehensive study of leakage reduction techniques applicable to CMOS based devices. In the process, mathematical equations that model the power-performance trade-offs in CMOS logic circuits are presented. From those equations...

  9. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  10. Marginal Leakage of Class V Composite Resin Restorations

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2018-01-01

    Full Text Available >Introduction: Marginal leakage is one of the significant causes of restoration failure. This in-vitro study was conducted to compare cone beam computed tomography (CBCT and dye-penetration methods for determining marginal leakage at gingival surface of class V resin composite restorations.Materials and Methods: Class V cavities were prepared on the buccal surfaces of nineteen caries-free extracted human molar teeth. Cavities were conditioned and filled. The teeth were immersed in a 50% w/w aqueous silver nitrate solution for 24 h and were taken out and rinsed with distilled water. Then, they were put into a developing solution. Whole specimens were first viewed with CBCT and were then sectioned and evaluated by stereomicroscope.Results: Measurement of agreement between CBCT and stereomicroscope revealed that 15 (78.9% teeth had score 0, 1 (5.3% tooth had score 1, and 1 (5.3% tooth had score 2 in both techniques. Measurement of agreement between CBCT and stereomicroscope techniques, in the detection of marginal leakage, was 89.5% (Kappa coefficient = 0.627, P = 0.00. The Wilcoxon paired rank test revealed no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin (P = 0.157.Conclusion: Considering the limitations of the study, there was no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin of class V composite restorations. CBCT can be used noninvasively to detect the marginal leakage of gingival wall of class V composite restorations using aqueous silver nitrate solution as a tracer.

  11. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  12. Development of references of anomalies detection on P91 material using Self-Magnetic Leakage Field (SMLF) technique

    Science.gov (United States)

    Husin, Shuib; Afiq Pauzi, Ahmad; Yunus, Salmi Mohd; Ghafar, Mohd Hafiz Abdul; Adilin Sekari, Saiful

    2017-10-01

    This technical paper demonstrates the successful of the application of self-magnetic leakage field (SMLF) technique in detecting anomalies in weldment of a thick P91 materials joint (1 inch thickness). Boiler components such as boiler tubes, stub boiler at penthouse and energy piping such as hot reheat pipe (HRP) and H-balance energy piping to turbine are made of P91 material. P91 is ferromagnetic material, therefore the technique of self-magnetic leakage field (SMLF) is applicable for P91 in detecting anomalies within material (internal defects). The technique is categorized under non-destructive technique (NDT). It is the second passive method after acoustic emission (AE), at which the information on structures radiation (magnetic field and energy waves) is used. The measured magnetic leakage field of a product or component is a magnetic leakage field occurring on the component’s surface in the zone of dislocation stable slipbands under the influence of operational (in-service) or residual stresses or in zones of maximum inhomogeneity of metal structure in new products or components. Inter-granular and trans-granular cracks, inclusion, void, cavity and corrosion are considered types of inhomogeneity and discontinuity in material where obviously the output of magnetic leakage field will be shown when using this technique. The technique does not required surface preparation for the component to be inspected. This technique is contact-type inspection, which means the sensor has to touch or in-contact to the component’s surface during inspection. The results of application of SMLF technique on the developed P91 reference blocks have demonstrated that the technique is practical to be used for anomaly inspection and detection as well as identification of anomalies’ location. The evaluation of this passive self-magnetic leakage field (SMLF) technique has been verified by other conventional non-destructive tests (NDTs) on the reference blocks where simulated

  13. Air leakage test of reactor hall using tracer technique

    International Nuclear Information System (INIS)

    Yang Yanqiu; Yang Liang; Yang Tongzai

    2011-01-01

    The leakage ratios of three related reactor halls were tested by sulfur hexafluoride gaseous tracer technique. Moreover, the accumulation intensities of leak gas and its retention time in some important working rooms, the crossroads of corridors and anteroom of the building were detected. The results show that the air leakage ratios of the three reactor halls are (7.30±0.16) x 10 -4 , (1.88±0.12) x 10 -4 and (2.07±0.07) x 10 -4 h -1 . The leak gas accumulates in all the detected working rooms fast, and the retention time to various rooms is about 5 h. The heaviest intensities are in the clothes change rooms on the first floor. However, the retention time to the crossroads and the anteroom is about 10 h, and the accumulation intensities are much small. (authors)

  14. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  15. A leakage-free resonance sparse decomposition technique for bearing fault detection in gearboxes

    Science.gov (United States)

    Osman, Shazali; Wang, Wilson

    2018-03-01

    Most of rotating machinery deficiencies are related to defects in rolling element bearings. Reliable bearing fault detection still remains a challenging task, especially for bearings in gearboxes as bearing-defect-related features are nonstationary and modulated by gear mesh vibration. A new leakage-free resonance sparse decomposition (LRSD) technique is proposed in this paper for early bearing fault detection of gearboxes. In the proposed LRSD technique, a leakage-free filter is suggested to remove strong gear mesh and shaft running signatures. A kurtosis and cosine distance measure is suggested to select appropriate redundancy r and quality factor Q. The signal residual is processed by signal sparse decomposition for highpass and lowpass resonance analysis to extract representative features for bearing fault detection. The effectiveness of the proposed technique is verified by a succession of experimental tests corresponding to different gearbox and bearing conditions.

  16. A Low Leakage Autonomous Data Retention Flip-Flop with Power Gating Technique

    Directory of Open Access Journals (Sweden)

    Xiaohui Fan

    2014-01-01

    Full Text Available With the scaling of technology process, leakage power becomes an increasing portion of total power. Power gating technology is an effective method to suppress the leakage power in VLSI design. When the power gating technique is applied in sequential circuits, such as flip-flops and latches, the data retention is necessary to store the circuit states. A low leakage autonomous data retention flip-flop (ADR-FF is proposed in this paper. Two high-Vth transistors are utilized to reduce the leakage power consumption in the sleep mode. The data retention cell is composed of a pair of always powered cross-coupled inverters in the slave latch. No extra control signals and complex operations are needed for controlling the data retention and restoration. The data retention flip-flops are simulated with NCSU 45 nm technology. The postlayout simulation results show that the leakage power of the ADR-FF reduces 51.39% compared with the Mutoh-FF. The active power of the ADR-FF is almost equal to other data retention flip-flops. The average state mode transition time of ADR-FF decreases 55.98%, 51.35%, and 21.07% as compared with Mutoh-FF, Balloon-FF, and Memory-TG-FF, respectively. Furthermore, the area overhead of ADR-FF is smaller than other data retention flip-flops.

  17. Space Vector Modulation Technique to Reduce Leakage Current of a Transformerless Three-Phase Four-Leg Photovoltaic System

    Directory of Open Access Journals (Sweden)

    F. Hasanzad

    2017-06-01

    Full Text Available Photovoltaic systems integrated to the grid have received considerable attention around the world. They can be connected to the electrical grid via galvanic isolation (transformer or without it (transformerless. Despite making galvanic isolation, low frequency transformer increases size, cost and losses. On the other hand, transformerless PV systems increase the leakage current (common-mode current, (CMC through the parasitic capacitors of the PV array. Inverter topology and switching technique are the most important parameters the leakage current depends on. As there is no need to extra hardware for switching scheme modification, it's an economical method for reducing leakage current. This paper evaluates the effect of different space vector modulation techniques on leakage current for a two-level three-phase four-leg inverter used in PV system. It proposes an efficient space vector modulation method which decreases the leakage current to below the quantity specified in VDE-0126-1-1 standard. furthermore, some other characteristics of the space vector modulation schemes that have not been significantly discussed for four-leg inverter, are considered, such as, modulation index, switching actions per period, common-mode voltage (CMV, and total harmonic distortion (THD. An extend software simulation using MATLAB/Simulink is performed to verify the effectiveness of the modulation technique.

  18. A new circuit technique for reduced leakage current in Deep Submicron CMOS technologies

    Directory of Open Access Journals (Sweden)

    A. Schmitz

    2005-01-01

    Full Text Available Modern CMOS processes in the Deep Submicron regime are restricted to supply voltages below 2 volts and further to account for the transistors' field strength limitations and to reduce the power per logic gate. To maintain the high switching performance, the threshold voltage must be scaled according with the supply voltage. However, this leads to an increased subthreshold current of the transistors in standby mode (VGS=0. Another source of leakage is gate current, which becomes significant for gate oxides of 3nm and below. We propose a Self-Biasing Virtual Rails (SBVR - CMOS technique which acts like an adaptive local supply voltage in case of standby mode. Most important sources of leakage currents are reduced by this technique. Moreover, SBVR-CMOS is capable of conserving stored information in sleep mode, which is vital for memory circuits. Memories are exposed to radiation causing soft errors. This well-known problem becomes even worse in standby mode of typical SRAMs, that have low driving performance to withstand alpha particle hits. In this paper, a 16-transistor SRAM cell is proposed, which combines the advantage of extremely low leakage currents with a very high soft error stability.

  19. Evaluation of inverse modeling techniques for pinpointing water leakages at building constructions

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2015-01-01

    The location and nature of the moisture leakages are sometimes difficult to detect. Moreover, the relation between observed inside surface moisture patterns and where the moisture enters the construction is often not clear. The objective of this paper is to investigate inverse modeling techniques as

  20. Endoscopic endonasal skull base surgery: advantages, limitations, and our techniques to overcome cerebrospinal fluid leakage: technical note.

    Science.gov (United States)

    Ishii, Yudo; Tahara, Shigeyuki; Teramoto, Akira; Morita, Akio

    2014-01-01

    In recent years, resections of midline skull base tumors have been conducted using endoscopic endonasal skull base (EESB) approaches. Nevertheless, many surgeons reported that cerebrospinal fluid (CSF) leakage is still a major complication of these approaches. Here, we report the results of our 42 EESB surgeries and discuss the advantages and limits of this approach for resecting various types of tumors, and also report our technique to overcome CSF leakage. All 42 cases involved midline skull base tumors resected using the EESB technique. Dural incisions were closed using nasoseptal flaps and fascia patch inlay sutures. Total removal of the tumor was accomplished in seven pituitary adenomas (33.3%), five craniopharyngiomas (62.5%), five tuberculum sellae meningiomas (83.3%), three clival chordomas (100%), and one suprasellar ependymoma. Residual regions included the cavernous sinus, the outside of the intracranial part of the internal carotid artery, the lower lateral part of the posterior clivus, and the posterior pituitary stalk. Overall incidence of CSF leakage was 7.1%. Even though the versatility of the approach is limited, EESB surgery has many advantages compared to the transcranial approach for managing mid-line skull base lesions. To avoid CSF leakage, surgeons should have skills and techniques for complete closure, including use of the nasoseptal flap and fascia patch inlay techniques.

  1. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  2. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent

    2012-01-01

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t’am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  3. Totally percutaneous rendezvous techniques for the treatment of bile strictures and leakages.

    Science.gov (United States)

    De Robertis, Riccardo; Contro, Alberto; Zamboni, Giulia; Mansueto, Giancarlo

    2014-04-01

    Some challenging pathologic conditions of the biliary tract cannot be treated with endoscopy alone, and a combined approach with rendezvous techniques is frequently needed. Three different totally percutaneous rendezvous techniques were successfully applied in three cases. The rendezvous techniques were performed either with bilateral catheterization of bile ducts to treat a challenging type IV biliary stenosis and iatrogenic biliary damage or with biliary catheterization and percutaneous puncture of the anastomotic loop to treat a biliodigestive anastomosis failure with bile leakage. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  4. The Technique to Prevent the Data Leakage using Covert Channels

    Directory of Open Access Journals (Sweden)

    Anna Vasilievna Arkhangelskaya

    2013-12-01

    Full Text Available The purpose of the article was to analyze technique to prevent information leakage using covert channels. The main steps are as follows: involving covert channels identification, data throughput estimation, its elimination or limitation, audit and detection. Three schemes of identification had been analyzed: shared resources methodology, covert flow tree method, message sequence diagram method. Ways of guarantee information delivery from systems with low security level to systems with high security level have been investigated.

  5. Influence of the internal anatomy on the leakage of root canals filled with thermoplastic technique.

    Science.gov (United States)

    Al-Jadaa, Anas; Attin, T; Peltomäki, T; Heumann, C; Schmidlin, P R; Paquè, F

    2018-04-01

    The aim of this paper is to evaluate the influence of the internal anatomy on the leakage of root canals filled with the thermoplastic technique. The upper central incisors (UCI) and mesial roots of the lower molars (MRLM) (n = 12 each) were tested regarding leakage using the gas-enhanced permeation test (GEPT) after root filling. The quality of the root fillings was assessed using micro-computed tomography (μCT) by superimposing scans before and after treatment to calculate unfilled volume. The calculated void volume was compared between the groups and correlated to the measured leakage values. Data were analyzed using t test and Pearson's correlation tests (p anatomy should be considered.

  6. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  7. "Rendezvous technique" for intraluminal vacuum therapy of anastomotic leakage of the jejunum.

    Science.gov (United States)

    Krajinovic, K; Reimer, S; Kudlich, T; Germer, C T; Wiegering, A

    2016-12-01

    Anastomotic leakage (AL) is one of the most common and serious complications following visceral surgery. In recent years, endoluminal vacuum therapy has dramatically changed therapeutic options for AL, but its use has been limited to areas easily accessible by endoscope. We describe the first use of endoluminal vacuum therapy in the small intestine employing a combined surgical and endoscopic "rendezvous technique" in which the surgeon assists the endoscopic placement of an endoluminal vacuum therapy sponge in the jejunum by means of a pullback string. This technique led to a completely closed AL after 27 days and 7 changes of the endosponge. The combined surgical and endoscopic rendezvous technique can be useful in cases of otherwise difficult endosponge placement.

  8. Quantitative single-vesicle analysis of antimicrobial peptide-induced leakage

    DEFF Research Database (Denmark)

    Kristensen, Kasper; Ehrlich, Nicky; Henriksen, Jonas Rosager

    2013-01-01

    Although the research field of antimicrobial peptides has attracted considerable scientific attention in the past decades, the microbicidal mechanisms of antimicrobial peptides still remain elusive. One of the keys to a more profound comprehension of the function of these peptides is a deeper...... was combined with fluorescence correlation spectroscopy to quantify leakage from a bulk collection of lipid vesicles in aqueous solution. Quantitative correlation between the two techniques was achieved through a detailed experimental protocol. The potential of combining the two techniques was tested using...

  9. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  10. ANOVA-HDMR structure of the higher order nodal diffusion solution

    International Nuclear Information System (INIS)

    Bokov, P. M.; Prinsloo, R. H.; Tomasevic, D. I.

    2013-01-01

    Nodal diffusion methods still represent a standard in global reactor calculations, but employ some ad-hoc approximations (such as the quadratic leakage approximation) which limit their accuracy in cases where reference quality solutions are sought. In this work we solve the nodal diffusion equations utilizing the so-called higher-order nodal methods to generate reference quality solutions and to decompose the obtained solutions via a technique known as High Dimensional Model Representation (HDMR). This representation and associated decomposition of the solution provides a new formulation of the transverse leakage term. The HDMR structure is investigated via the technique of Analysis of Variance (ANOVA), which indicates why the existing class of transversely-integrated nodal methods prove to be so successful. Furthermore, the analysis leads to a potential solution method for generating reference quality solutions at a much reduced calculational cost, by applying the ANOVA technique to the full higher order solution. (authors)

  11. The White test: a new dye test for intraoperative detection of bile leakage during major liver resection.

    Science.gov (United States)

    Nadalin, Silvio; Li, Jun; Lang, Hauke; Sotiropoulos, Georgios C; Schaffer, Randolph; Radtke, Arnold; Saner, Fuat; Broelsch, Christoph E; Malagó, Massimo

    2008-04-01

    To describe a new intraoperative bile leakage test in patients undergoing a major liver resection aimed to combine the advantages of each of the other standard bile leakage tests (accurate visualization of leaks, reproducibility, and ease of use) without their disadvantages. At the end of the major hepatic resection, 10 to 30 mL of sterile fat emulsion, 5%, is injected via an olive-tip cannula through the cystic duct while manually occluding the distal common bile duct. As the biliary tree fills with fat emulsion solution, leakage of the white fluid is visualized on the raw surface of the liver resection margin. The detected leakages are closed by means of single stitches. Afterwards, the residual fat emulsion on the resection surface is washed off with saline and the White test is repeated to detect and/or exclude additional bile leakages. At the end, residual fat emulsion is washed out from the biliary tract by a low-pressure infusion of saline solution. Intraoperatively, additional potential bile leakages (not seen using a conventional saline bile leakage test) were identified in 74% of our patients. Postoperative bile leakages (within 30 days) occurred in only 5.1% of patients when the White test was used. No adverse effects related to this technique were observed. The White test has clear advantages in comparison with other bile leakage tests: it precisely detects bile leakages, regardless of size; it does not stain the resection surface, allowing it to be washed off and repeated ad infinitum; and it is safe, quick, and inexpensive.

  12. Solution of the mathematical adjoint equations for an interface current nodal formulation

    International Nuclear Information System (INIS)

    Yang, W.S.; Taiwo, T.A.; Khalil, H.

    1994-01-01

    Two techniques for solving the mathematical adjoint equations of an interface current nodal method are described. These techniques are the ''similarity transformation'' procedure and a direct solution scheme. A theoretical basis is provided for the similarity transformation procedure originally proposed by Lawrence. It is shown that the matrices associated with the mathematical and physical adjoint equations are similar to each other for the flat transverse leakage approximation but not for the quadratic leakage approximation. It is also shown that a good approximate solution of the mathematical adjoint for the quadratic transverse leakage approximation is obtained by applying the similarity transformation for the flat transverse leakage approximation to the physical adjoint solution. The direct solution scheme, which was developed as an alternative to the similarity transformation procedure, yields the correct mathematical adjoint solution for both flat and quadratic transverse leakage approximations. In this scheme, adjoint nodal equations are cast in a form very similar to that of the forward equations by employing a linear transformation of the adjoint partial currents. This enables the use of the forward solution algorithm with only minor modifications for solving the mathematical adjoint equations. By using the direct solution scheme as a reference method, it is shown that while the results computed with the similarity transformation procedure are approximate, they are sufficiently accurate for calculations of global and local reactivity changes resulting from coolant voiding in a liquid-metal reactor

  13. A severity-based quantification of data leakages in database systems

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.

    2016-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. However, these solutions often produce a large number of alerts,

  14. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    OpenAIRE

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was c...

  15. A PD-SOI based DTI-LOCOS combined cross isolation technique for minimizing TID radiation induced leakage in high density memory

    International Nuclear Information System (INIS)

    Qiao Fengying; Pan Liyang; Wu Dong; Liu Lifang; Xu Jun

    2014-01-01

    In order to minimize leakage current increase under total ionizing dose (TID) radiation in high density memory circuits, a new isolation technique, combining deep trench isolation (DTI) between the wells, local oxidation of silicon (LOCOS) isolation between the devices within the well, and a P-diffused area in order to limit leakage at the isolation edge is implemented in partly-depleted silicon-on-insulator (PD-SOI) technology. This radiation hardening technique can minimize the layout area by more than 60%, and allows flexible placement of the body contact. Radiation hardened transistors and 256 Kb flash memory chips are designed and fabricated in a 0.6 μm PD-SOI process. Experiments show that no obvious increase in leakage current is observed for single transistors under 1 Mrad(Si) radiation, and that the 256 Kb memory chip still functions well after a TID of 100 krad(Si), with only 50% increase of the active power consumption in read mode. (semiconductor devices)

  16. Evaluation of the Sealing Ability of Three Obturation Techniques Using a Glucose Leakage Test

    Directory of Open Access Journals (Sweden)

    Katarzyna Olczak

    2017-01-01

    Full Text Available The aim of this study was to evaluate the sealing ability of three different canal filling techniques. Sixty-four roots of extracted human maxillary anterior teeth were prepared using ProTaper® rotary instruments. The specimens were then randomly divided into 3 experimental groups (n=16 and 2 control groups (n=8. The root canals were filled using cold lateral compaction (CLC group, continuous wave condensation technique using the Elements Obturation Unit® (EOU group, and ProTaper obturators (PT group. For the negative control group, 8 roots were filled using lateral compaction as in the CLC group, and the teeth were covered twice with a layer of nail varnish (NCG group. Another 8 roots were filled using lateral compaction, but without sealer, and these were used as the positive control (PCG group. A glucose leakage model was used for quantitative evaluation of microleakage for 24 hours and 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, and 12 weeks. No significant difference in the cumulative amount of leakage was found between the three experimental groups at all observation times. The lateral condensation of cold gutta-percha can guarantee a similar seal of canal fillings as can be achieved by using thermal methods, in the round canals.

  17. Evaluation of the white test for the intraoperative detection of bile leakage.

    Science.gov (United States)

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  18. Performance of evaluation techniques for planning preventive repair of leakages on BWR vessel stub tubes

    International Nuclear Information System (INIS)

    Prat, J.P.

    1985-01-01

    Stub tubes have been installed on the control rod drive assemblies of the majority of boiling water reactor vessel bottoms. These stub tubes can undergo a slow process of cracking, producing no potential hazard but occasional plant unavailability due to leakage in excess of specification limits. In the case considered here, the development and application of remotely controlled equipment permitting access both from inside and outside the housing, and of crack evolution and location techniques, has made the progressive development, selection and planning of repairs a possibility, thus minimizing the risk of leakages appearing between refuelling outages. The example used here is of a Nuclear Power Plant in which a first leak appeared in 1981. Since that time extensive and progressive laboratory and field development work has been carried out. This paper presents the experience gained with customized, remote-control inspection equipment, and several developed or adapted techniques, as the basis for an in-service repair decision tree, the case in question being that of a BWR plant in which a cracking process, not affecting safety but potentially affecting availability, has given rise to leaks after ten years of operation

  19. Motor current and leakage flux signature analysis technique for condition monitoring

    International Nuclear Information System (INIS)

    Pillai, M.V.; Moorthy, R.I.K.; Mahajan, S.C.

    1994-01-01

    Till recently analysis of vibration signals was the only means available to predict the state of health of plant equipment. Motor current and leakage magnetic flux signature analysis is acquiring importance as a technique for detection of incipient damages in the electrical machines and as a supplementary technique for diagnostics of driven equipment such as centrifugal and reciprocating pumps. The state of health of the driven equipment is assessed by analysing time signal, frequency spectrum and trend analysis. For example, the pump vane frequency, piston stroke frequency, gear frequency and bearing frequencies are indicated in the current and flux spectra. By maintaining a periodic record of the amplitudes of various frequency lines in the frequency spectra, it is possible to understand the trend of deterioration of parts and components of the pump. All problems arising out of inappropriate mechanical alignment of vertical pumps are easily identified by a combined analysis of current, flux and vibration signals. It is found that current signature analysis technique is a sufficient method in itself for the analysis of state of health of reciprocating pumps and compressors. (author). 10 refs., 4 figs

  20. Integration of geotechnical and geophysical techniques for the characterization of a small earth-filled canal dyke and the localization of water leakage

    Science.gov (United States)

    Bièvre, Grégory; Lacroix, Pascal; Oxarango, Laurent; Goutaland, David; Monnot, Guy; Fargier, Yannick

    2017-04-01

    This paper investigates the combined use of extensive geotechnical, hydrogeological and geophysical techniques to assess a small earth dyke with a permanent hydraulic head, namely a canal embankment. The experimental site was chosen because of known issues regarding internal erosion and piping phenomena. Two leakages were visually located following the emptying of the canal prior to remediation works. The results showed a good agreement between the geophysical imaging techniques (Electrical Resistivity Tomography, P- and SH-waves Tomography) and the geotechnical data to detect the depth to the bedrock and its lateral variations. It appeared that surface waves might not be fully adapted for dyke investigation because of the particular geometry of the studied dyke, non-respectful of the 1D assumption, and which induced depth and velocity discrepancies retrieved from Rayleigh and Love waves inversion. The use of these classical prospecting techniques however did not allow to directly locate the two leakages within the studied earth dyke. The analysis of ambient vibration time series with a modified beam-forming algorithm allowed to localize the most energetic water flow prior to remediation works. It was not possible to detect the leakage after remediation works, suggesting that they efficiently contributed to significantly reduce the water flow. The second leakage was not detected probably because of a non-turbulent water flow, generating few energetic vibrations.

  1. [Detection of marginal leakage of Class V restorations in vitro by micro-CT].

    Science.gov (United States)

    Gu, Lin-juan; Zhao, Xin-yi; Li, Shi-bao

    2012-09-01

    To evaluate the reliability and superiority of micro-CT in marginal leakage assessment of Class V restorations. Class V preparations with gingival margins in dentin and occlusal in enamel were made in sixteen extracted non-carious human molars and restored with dental bonding agents and composite resin. All teeth were then immersed in 50% ammonia-silver nitrate solution for 12 hours, followed by developing solution for 8 hours. Each restoration was scanned by a micro-CT and silver leakage was measured and three-dimensional image of the silver leakage alone cavity wall were reconstructed. Afterward, all restorations were sectioned and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by micro-CT and microscope were compared for equivalency. The silver leakage depths in gingival wall obtained with micro-CT (0.78 mm) and microscope (0.74 mm) showed no significant difference (P > 0.05), while the judgment of leakage depths in occlusal wall in micro-CT image (0.40 mm) was affected by adjacent enamel structure, giving less leakage depths compared to microscope (0.72 mm)(P leakages showed channels on their way to spreading. Micro-CT can detect precisely the silver leakage in the dentin wall of a restoration and display its three-dimensional shape fully. Enamel structure affects the detection of the silver leakage next to it.

  2. Model-based monitoring techniques for leakage localization in distribution water networks

    OpenAIRE

    Meseguer Amela, Jordi; Mirats Tur, Josep Maria; Cembrano Gennari, Gabriela; Puig Cayuela, Vicenç

    2015-01-01

    This is an open access article under the CC BY-NC-ND license This paper describes an integrated model-based monitoring framework for leakage localization in district-metered areas (DMA) of water distribution networks, which takes advantage of the availability of a hydraulic model of the network. The leakage localization methodology is based on the use of flow and pressure sensors at the DMA inlets and a limited number of pressure sensors deployed inside the DMA. The placement of these sens...

  3. Estimation of leakage power and delay in CMOS circuits using parametric variation

    Directory of Open Access Journals (Sweden)

    Preeti Verma

    2016-09-01

    Full Text Available With the advent of deep-submicron technologies, leakage power dissipation is a major concern for scaling down portable devices that have burst-mode type integrated circuits. In this paper leakage reduction technique HTLCT (High Threshold Leakage Control Transistor is discussed. Using high threshold transistors at the place of low threshold leakage control transistors, result in more leakage power reduction as compared to LCT (leakage control transistor technique but at the scarifies of area and delay. Further, analysis of effect of parametric variation on leakage current and propagation delay in CMOS circuits is performed. It is found that the leakage power dissipation increases with increasing temperature, supply voltage and aspect ratio. However, opposite pattern is noticed for the propagation delay. Leakage power dissipation for LCT NAND gate increases up to 14.32%, 6.43% and 36.21% and delay decreases by 22.5%, 42% and 9% for variation of temperature, supply voltage and aspect ratio. Maximum peak of equivalent output noise is obtained as 127.531 nV/Sqrt(Hz at 400 mHz.

  4. A white-box anomaly-based framework for database leakage detection

    NARCIS (Netherlands)

    Costante, E.; den Hartog, J.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.

    2017-01-01

    Data leakage is at the heart most of the privacy breaches worldwide. In this paper we present a white-box approach to detect potential data leakage by spotting anomalies in database transactions. We refer to our solution as white-box because it builds self explanatory profiles that are easy to

  5. Effects of Repeated Screw Tightening on Implant Abutment Interfaces in Terms of Bacterial and Yeast Leakage in Vitro: One-Time Abutment Versus the Multiscrewing Technique.

    Science.gov (United States)

    Calcaterra, Roberta; Di Girolamo, Michele; Mirisola, Concetta; Baggi, Luigi

    2016-01-01

    Screw loosening can damage the interfaces of implant components, resulting in susceptibility to contamination of the internal parts by microorganisms. The aim of this study was to investigate the impact of abutment screw retightening on the leakage of two different types of bacteria, Streptococcus sanguinis and Fusobacterium nucleatum, and of the yeast Candida albicans. Two types of implant-abutment systems with tube-in-tube interfaces were tested. Groups A and B each used a different type of system that consisted of 20 different pieces that were assembled according to the manufacturer's torque recommendations; four samples in each group were closed just one time, four samples three times, four samples five times, four samples seven times, and four samples nine times. The implants of groups A and B were contaminated with 0.1 μL of microbial solution just before being assembled for the last time to minimize the possibility of contamination. Results showed a direct correlation between the number of colony-forming units grown in the plates and the closing/opening cycles of the implant-abutment systems. Within the limitations of this study, the results indicate the possibility that repeated closing/opening cycles of the implant-abutment unit may influence bacterial/yeast leakage, most likely as a consequence of decreased precision of the coupling between the abutment and the internal part of the dental implant. These findings suggest that a one-time abutment technique may avoid microbiologic leakage in cases of implant-abutment systems with tube-in-tube interfaces.

  6. An Ice Block: A Novel Technique of Successful Prevention of Cement Leakage Using an Ice Ball

    Energy Technology Data Exchange (ETDEWEB)

    Uri, Ishaq Fahmi, E-mail: uri.isaac@gmail.com [The Royal National Orthopaedic Hospital (United Kingdom); Garnon, Julien, E-mail: juliengarnon@gmail.com; Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpital Universitaire de Strasbourg, Service d’Imagerie Interventionnelle (France)

    2015-04-15

    We report three cases of painful bone metastases with extraosseous invasion treated with cementoplasty and cryoablation. Due to significant cortical loss in all cases, the ice ball was used simultaneously during cementoplasty to deter potential cement leakage. This was achieved by direct application of the ice ball against the cortical surface, resulting in adequate consolidation and successful containment of the cement within the treated bones. To the authors’ knowledge, this is the first report to describe such a combined technique.

  7. In-vitro comparison of micro-leakage between nanocomposite and microhybrid composite in class v cavities treated with the self-etch technique

    International Nuclear Information System (INIS)

    Mahvish, S.; Khan, F.R.

    2016-01-01

    Background: When a light cure composite resin is used to restore a class V lesion, certain stresses are generated at the tooth-restoration interface. If these stresses exceed the bond strength of the restorative material, microscopic gaps are formed which eventually cause micro-leakage at the tooth-restoration interface. The objective of the present study was to compare the micro-leakage values at the tooth-restoration interface using dye penetration method between a Nano filled and a Micro hybrid light cured composite resin in class V cavities using the self-etch technique. Methods: Sixty class V cavities were made coronal to the cemento-enamel junction in the extracted premolars. These were then randomly divided into two study groups. Group A: Self-etch; filled with P-60 (micro-hybrid) n=30. Group B: Self-etch; filled with Z-350 (nano-filled) n=30. Specimens were subjected to thermo-cycling at 5-55 degree C ± 2 degree C with a 30 seconds dwell time. After which they were stained with 2% methylene blue. Later, sectioned bucco-lingually and examined using a stereo microscope (magnification X4) at the occlusal, axial and gingival surfaces. Micro-leakage around the tooth-restoration interface was assessed by using the degree of dye penetration in millimetres. Results: There was 100% micro leakage seen at both the occlusal and gingival surfaces when using the P-60 composite. With the Z-350 composite 84% occlusal and 88% of the gingival surfaces exhibited micro-leakage. Conclusions: With respect to micro-leakage in class V cavities, Z-350 was found to be a superior restorative material compared to P-60 on the occlusal surface. Overall, there is no statistically significant difference in the micro-leakage exhibited by the two restorative materials in class V preparations subjected to self-etch protocol. (author)

  8. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  9. [Bile leakage after liver resection: A retrospective cohort study].

    Science.gov (United States)

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (pBile leakage significantly prolonged hospitalization time (pbile leakage the perioperative mortality was 23 times higher (pBile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve

  10. Membrane damage and solute leakage from germinating pea seed under cadmium stress

    Energy Technology Data Exchange (ETDEWEB)

    Rahoui, Sondes, E-mail: rahoui.sondes@yahoo.fr [Bio-Physiologie Cellulaires, Departement des Sciences de la Vie, Faculte des Sciences de Bizerte, 7021 Zarzouna (Tunisia); Chaoui, Abdelilah, E-mail: cabdelilah1@yahoo.fr [Bio-Physiologie Cellulaires, Departement des Sciences de la Vie, Faculte des Sciences de Bizerte, 7021 Zarzouna (Tunisia); El Ferjani, Ezzeddine, E-mail: ezzferjani2002@yahoo.fr [Bio-Physiologie Cellulaires, Departement des Sciences de la Vie, Faculte des Sciences de Bizerte, 7021 Zarzouna (Tunisia)

    2010-06-15

    Seed germination represents a limiting stage of plant life cycle under heavy metal stress situation. Delay in germination can be associated with disorders in the event chain of germinative metabolism which is a highly complex multistage process, but one of underlying metabolic activities following imbibition of seed is the storage mobilization. The influence of cadmium on carbohydrates and aminoacids export from cotyledon to embryonic axis during germination of pea seed was investigated. Compared to the control, Cd caused a restriction in reserve mobilization as evidenced by the pronounced increase in cotyledon/embryo ratios of total soluble sugars, glucose, fructose and aminoacids. Moreover, the nutrient concentrations, as well as the electrical conductivity of germination medium were determined to quantify the extent of solute leakage. Such nutrients were lost into the imbibition medium at the expense of suitable mobilization to the growing embryonic axis. This was concomitant with an over-accumulation of lipid peroxidation products in Cd-poisoned embryonic tissues. However, the impairment of membrane integrity cannot be due to a stimulation in lipoxygenase activity, since the later was markedly inhibited after Cd exposure.

  11. Membrane damage and solute leakage from germinating pea seed under cadmium stress

    International Nuclear Information System (INIS)

    Rahoui, Sondes; Chaoui, Abdelilah; El Ferjani, Ezzeddine

    2010-01-01

    Seed germination represents a limiting stage of plant life cycle under heavy metal stress situation. Delay in germination can be associated with disorders in the event chain of germinative metabolism which is a highly complex multistage process, but one of underlying metabolic activities following imbibition of seed is the storage mobilization. The influence of cadmium on carbohydrates and aminoacids export from cotyledon to embryonic axis during germination of pea seed was investigated. Compared to the control, Cd caused a restriction in reserve mobilization as evidenced by the pronounced increase in cotyledon/embryo ratios of total soluble sugars, glucose, fructose and aminoacids. Moreover, the nutrient concentrations, as well as the electrical conductivity of germination medium were determined to quantify the extent of solute leakage. Such nutrients were lost into the imbibition medium at the expense of suitable mobilization to the growing embryonic axis. This was concomitant with an over-accumulation of lipid peroxidation products in Cd-poisoned embryonic tissues. However, the impairment of membrane integrity cannot be due to a stimulation in lipoxygenase activity, since the later was markedly inhibited after Cd exposure.

  12. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  13. Rendezvous technique treatment for late-onset biliary leakage after major hepatectomy of a living donor: report of a case.

    Science.gov (United States)

    Kimura, Koichi; Ikegami, Toru; Yamashita, Yo-ichi; Saeki, Hiroshi; Oki, Eiji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Kawanaka, Hirofumi; Soejima, Yuji; Morita, Masaru; Shirabe, Ken; Ikeda, Tetsuo; Maehara, Yoshihiko

    2013-09-01

    Biliary leakage is a major complication after hepatectomy. We report the case of a living-donor liver transplantation (LDLT) donor with a late-onset bile leak from the trifurcation of the hepatic duct who was successfully treated using rendezvous technique. A 52-year-old man underwent extended left hepatectomy for donation and was discharged on postoperative day (PD) 13. However, he was rehospitalized on PD 26 with severe abdominal pain. Physical examination suggested panperitonitis, and abdominocentesis showed bilious ascites. Emergent laparotomy for biliary leakage and peritonitis was performed. There was bilious ascites in the peritoneal cavity. A biliary fistula was recognized at the trifurcation of B8a, B8b, and B5. Intraoperative transhepatic biliary drainage of each bile duct was performed. Endoscopic transpapillary drainage was performed on PD 24. Finally, external drains were removed and complete internal drainage established on PD 70. The bile leak was considered to be the result of injury from electrocautery device. Appropriate making choices of the electrocautery devices enable us to avoid over thermal injury of the liver surface. Rendezvous bidirectional drainage effectively treated late-onset bile leakage from the trifurcation of a hepatic bile duct.

  14. Geologic Carbon Sequestration Leakage Detection: A Physics-Guided Machine Learning Approach

    Science.gov (United States)

    Lin, Y.; Harp, D. R.; Chen, B.; Pawar, R.

    2017-12-01

    One of the risks of large-scale geologic carbon sequestration is the potential migration of fluids out of the storage formations. Accurate and fast detection of this fluids migration is not only important but also challenging, due to the large subsurface uncertainty and complex governing physics. Traditional leakage detection and monitoring techniques rely on geophysical observations including pressure. However, the resulting accuracy of these methods is limited because of indirect information they provide requiring expert interpretation, therefore yielding in-accurate estimates of leakage rates and locations. In this work, we develop a novel machine-learning technique based on support vector regression to effectively and efficiently predict the leakage locations and leakage rates based on limited number of pressure observations. Compared to the conventional data-driven approaches, which can be usually seem as a "black box" procedure, we develop a physics-guided machine learning method to incorporate the governing physics into the learning procedure. To validate the performance of our proposed leakage detection method, we employ our method to both 2D and 3D synthetic subsurface models. Our novel CO2 leakage detection method has shown high detection accuracy in the example problems.

  15. Reanastomosis with Stapler in Duodenojejunal Junction Anastomosis Leakage: A Case Report

    Directory of Open Access Journals (Sweden)

    Ahmet Seker

    2013-04-01

    Full Text Available After anastomosis leakages, treatment of patient gets more difficult and mortality rates increase. At lower level gastrointestinal anastomosis leakages, because of always there is an ostomy alternative, digestion problems are seen lesser. But at upper level gastrointestinal system anastomosis leakages, when it is taken account of nutrient condition of patient, requirement of making anastomos increases. So moratlity rates increase. At this article we aimed to present a different technique that we administered on management of a patient who had duodenojejunal junction anastomosis leakage.

  16. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  17. Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

  18. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  19. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  20. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  1. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  2. Pulse sequences for suppressing leakage in single-qubit gate operations

    Science.gov (United States)

    Ghosh, Joydip; Coppersmith, S. N.; Friesen, Mark

    2017-06-01

    Many realizations of solid-state qubits involve couplings to leakage states lying outside the computational subspace, posing a threat to high-fidelity quantum gate operations. Mitigating leakage errors is especially challenging when the coupling strength is unknown, e.g., when it is caused by noise. Here we show that simple pulse sequences can be used to strongly suppress leakage errors for a qubit embedded in a three-level system. As an example, we apply our scheme to the recently proposed charge quadrupole (CQ) qubit for quantum dots. These results provide a solution to a key challenge for fault-tolerant quantum computing with solid-state elements.

  3. Detection of marginal leakage of Class V restorations in vitro by micro-computed tomography.

    Science.gov (United States)

    Zhao, X Y; Li, S B; Gu, L J; Li, Y

    2014-01-01

    This in vitro study evaluated the efficacy of micro-computed tomography (CT) in marginal leakage detection of Class V restorations. Standardized Class V preparations with cervical margins in dentin and occlusal margins in enamel were made in 20 extracted human molars and restored with dental bonding agents and resin composite. All teeth were then immersed in 50% ammoniacal silver nitrate solution for 12 hours, followed by a developing solution for eight hours. Each restoration was scanned by micro-CT, the depth of marginal silver leakage in the central scanning section was measured, and the three-dimensional images of the silver leakage around each restoration were reconstructed. Afterward, all restorations were cut through the center and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by the micro-CT and the microscope were compared for equivalency. The silver leakage depth in cervical walls observed by micro-CT and microscope showed no significant difference; however, in certain cases the judgment of leakage depth in the occlusal wall in micro-CT image was affected by adjacent enamel structure, providing less leakage depth than was observed with the microscope (pleakage around the Class V restorations with clear borders only in the dentin region. It can be concluded that micro-CT can detect nondestructively the leakage around a resin composite restoration in two and three dimensions, with accuracy comparable to that of the conventional microscope method in the dentin region but with inferior accuracy in the enamel region.

  4. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  5. Detecting the leakage source of a reservoir using isotopes.

    Science.gov (United States)

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Enhanced ground bounce noise reduction in a low-leakage CMOS multiplier

    Science.gov (United States)

    Verma, Bipin Kumar; Akashe, Shyam; Sharma, Sanjay

    2015-09-01

    In this paper, various parameters are used to reduce leakage power, leakage current and noise margin of circuits to enhance their performance. A multiplier is proposed with low-leakage current and low ground bounce noise for the microprocessor, digital signal processors (DSP) and graphics engines. The ground bounce noise problem appears when a conventional power-gating circuit transits from sleep-to-active mode. This paper discusses a reduction in leakage current in the stacking power-gating technique by three modes - sleep, active and sleep-to-active. The simulation results are performed on a 4 × 4 carry-save multiplier for leakage current, active power, leakage power and ground bounce noise, and comparison made for different nanoscales. Ground bounce noise is limited to 90%. The leakage current of the circuit is decimated up to 80% and the active power is reduced to 31%. We performed simulations using cadence virtuoso 180 and 45 nm at room temperature at various supply voltages.

  7. Parametrization of the radiation induced leakage current increase of NMOS transistors

    International Nuclear Information System (INIS)

    Backhaus, M.

    2017-01-01

    The increase of the leakage current of NMOS transistors during exposure to ionizing radiation is known and well studied. Radiation hardness by design techniques have been developed to mitigate this effect and have been successfully used. More recent developments in smaller feature size technologies do not make use of these techniques due to their drawbacks in terms of logic density and requirement of dedicated libraries. During operation the resulting increase of the supply current is a serious challenge and needs to be considered during the system design. A simple parametrization of the leakage current of NMOS transistors as a function of total ionizing dose is presented. The parametrization uses a transistor transfer characteristics of the parasitic transistor along the shallow trench isolation to describe the leakage current of the nominal transistor. Together with a parametrization of the number of positive charges trapped in the silicon dioxide and number of activated interface traps in the silicon to silicon dioxide interface the leakage current results as a function of the exposure time to ionizing radiation. This function is fitted to data of the leakage current of single transistors as well as to data of the supply current of full ASICs.

  8. Stress-induced leakage current characteristics of PMOS fabricated by a new multi-deposition multi-annealing technique with full gate last process

    International Nuclear Information System (INIS)

    Wang Yanrong; Yang Hong; Xu Hao; Luo Weichun; Qi Luwei; Zhang Shuxiang; Wang Wenwu; Zhu Huilong; Zhao Chao; Chen Dapeng; Ye Tianchun; Yan Jiang

    2017-01-01

    In the process of high- k films fabrication, a novel multi deposition multi annealing (MDMA) technique is introduced to replace simple post deposition annealing. The leakage current decreases with the increase of the post deposition annealing (PDA) times. The equivalent oxide thickness (EOT) decreases when the annealing time(s) change from 1 to 2. Furthermore, the characteristics of SILC (stress-induced leakage current) for an ultra-thin SiO 2 /HfO 2 gate dielectric stack are studied systematically. The increase of the PDA time(s) from 1 to 2 can decrease the defect and defect generation rate in the HK layer. However, increasing the PDA times to 4 and 7 may introduce too much oxygen, therefore the type of oxygen vacancy changes. (paper)

  9. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  10. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  11. High Tc superconductors using solution techniques

    International Nuclear Information System (INIS)

    Barboux, P.; Valente, I.; Henry, M.; Morineau, R.; Tarascon, J.M.; Khan, S.; Shokoohi, F.; Bagley, B.G.

    1989-01-01

    The authors have investigated different solution techniques to synthesize the Cu-based superconductors in the thick film form. Thick films of YBa 2 Cu 3 O 7 have been produced using controlled precipitation techniques. Bi-based and Tl-based materials have been deposited by spraying of ionic solutions. The numerous difficulties encountered during each process are analyzed in order to propose new synthesis procedures such as a new method, based on the precipitation of hydroxides only, which is described as a prospective for lowering the synthesis temperature and shortening the reaction time

  12. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    Science.gov (United States)

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  13. Colorectal anastomotic leakage: Aspects of prevention, detection and treatment

    NARCIS (Netherlands)

    F. Daams (Freek); M. Luyer (Misha); J.F. Lange (Johan)

    2013-01-01

    textabstractAll colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques

  14. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  15. Effect of condenser water in-leakage on steam generator water chemistry

    International Nuclear Information System (INIS)

    Balakrishnan, P.V.

    1978-01-01

    Corrosive environments may be generated within steam genrators from condenser cooling water in-leakage. Theoretical as well as experimental evaluation of the aggressiveness of such environments is being carried out for the condenser-cooling waters used at CANDU-PHW nuclear power stations. Calculations have shown that highly concentrated chloride solutions - acidic in the case of sea-water in-leakage, and alkaline in the rest of the cases considered - would be produced within the steam generator. Experiments in a model boiler showed that sea-water in-leakage caused rapid corrosion of carbon steel components when only AVT (all volatile treatment) was used for water chemistry control. Use of a non-volatile reagent, as in the congruent phosphate treatment, avoided the rapid corrosion of carbon steel. On the basis of our studies, congruent phosphate treatment during sea water in-leakage appears desirable. (author)

  16. Accurate characterization of organic thin film transistors in the presence of gate leakage current

    Directory of Open Access Journals (Sweden)

    Vinay K. Singh

    2011-12-01

    Full Text Available The presence of gate leakage through polymer dielectric in organic thin film transistors (OTFT prevents accurate estimation of transistor characteristics especially in subthreshold regime. To mitigate the impact of gate leakage on transfer characteristics and allow accurate estimation of mobility, subthreshold slope and on/off current ratio, a measurement technique involving simultaneous sweep of both gate and drain voltages is proposed. Two dimensional numerical device simulation is used to illustrate the validity of the proposed technique. Experimental results obtained with Pentacene/PMMA OTFT with significant gate leakage show a low on/off current ratio of ∼ 102 and subthreshold is 10 V/decade obtained using conventional measurement technique. The proposed technique reveals that channel on/off current ratio is more than two orders of magnitude higher at ∼104 and subthreshold slope is 4.5 V/decade.

  17. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  18. Evaluation of the Repeatability of the Delta Q Duct Leakage Testing TechniqueIncluding Investigation of Robust Analysis Techniques and Estimates of Weather Induced Uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Dickerhoff, Darryl; Walker, Iain

    2008-08-01

    The DeltaQ test is a method of estimating the air leakage from forced air duct systems. Developed primarily for residential and small commercial applications it uses the changes in blower door test results due to forced air system operation. Previous studies established the principles behind DeltaQ testing, but raised issues of precision of the test, particularly for leaky homes on windy days. Details of the measurement technique are available in an ASTM Standard (ASTM E1554-2007). In order to ease adoption of the test method, this study answers questions regarding the uncertainty due to changing weather during the test (particularly changes in wind speed) and the applicability to low leakage systems. The first question arises because the building envelope air flows and pressures used in the DeltaQ test are influenced by weather induced pressures. Variability in wind induced pressures rather than temperature difference induced pressures dominates this effect because the wind pressures change rapidly over the time period of a test. The second question needs to answered so that DeltaQ testing can be used in programs requiring or giving credit for tight ducts (e.g., California's Building Energy Code (CEC 2005)). DeltaQ modeling biases have been previously investigated in laboratory studies where there was no weather induced changes in envelope flows and pressures. Laboratory work by Andrews (2002) and Walker et al. (2004) found biases of about 0.5% of forced air system blower flow and individual test uncertainty of about 2% of forced air system blower flow. The laboratory tests were repeated by Walker and Dickerhoff (2006 and 2008) using a new ramping technique that continuously varied envelope pressures and air flows rather than taking data at pre-selected pressure stations (as used in ASTM E1554-2003 and other previous studies). The biases and individual test uncertainties for ramping were found to be very close (less than 0.5% of air handler flow) to those

  19. Application of Buckmaster Electrolyte Ion Leakage Test to Woody Biofuel Feedstocks

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Thomas F [Forest Concepts, LLC; Dooley, James H [Forest Concepts, LLC

    2014-08-28

    In an earlier ASABE paper, Buckmaster reported that ion conductivity of biomass leachate in aqueous solution was directly correlated with activity access to plant nutrients within the biomass materials for subsequent biological or chemical processing. The Buckmaster test involves placing a sample of the particles in a beaker of constant-temperature deionized water and monitoring the change in electrical conductivity over time. We adapted the Buckmaster method to a range of woody biomass and other cellulosic bioenergy feedstocks. Our experimental results suggest differences of electrolyte leakage between differently processed woody biomass particles may be an indicator of their utility for conversion in bioenergy processes. This simple assay appears to be particularly useful to compare different biomass comminution techniques and particle sizes for biochemical preprocessing.

  20. Model for CO2 leakage including multiple geological layers and multiple leaky wells.

    Science.gov (United States)

    Nordbotten, Jan M; Kavetski, Dmitri; Celia, Michael A; Bachu, Stefan

    2009-02-01

    Geological storage of carbon dioxide (CO2) is likely to be an integral component of any realistic plan to reduce anthropogenic greenhouse gas emissions. In conjunction with large-scale deployment of carbon storage as a technology, there is an urgent need for tools which provide reliable and quick assessments of aquifer storage performance. Previously, abandoned wells from over a century of oil and gas exploration and production have been identified as critical potential leakage paths. The practical importance of abandoned wells is emphasized by the correlation of heavy CO2 emitters (typically associated with industrialized areas) to oil and gas producing regions in North America. Herein, we describe a novel framework for predicting the leakage from large numbers of abandoned wells, forming leakage paths connecting multiple subsurface permeable formations. The framework is designed to exploit analytical solutions to various components of the problem and, ultimately, leads to a grid-free approximation to CO2 and brine leakage rates, as well as fluid distributions. We apply our model in a comparison to an established numerical solverforthe underlying governing equations. Thereafter, we demonstrate the capabilities of the model on typical field data taken from the vicinity of Edmonton, Alberta. This data set consists of over 500 wells and 7 permeable formations. Results show the flexibility and utility of the solution methods, and highlight the role that analytical and semianalytical solutions can play in this important problem.

  1. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  2. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  3. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  4. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Detection of concrete dam leakage using an integrated geophysical technique based on flow-field fitting method

    Science.gov (United States)

    Dai, Qianwei; Lin, Fangpeng; Wang, Xiaoping; Feng, Deshan; Bayless, Richard C.

    2017-05-01

    An integrated geophysical investigation was performed at S dam located at Dadu basin in China to assess the condition of the dam curtain. The key methodology of the integrated technique used was flow-field fitting method, which allowed identification of the hydraulic connections between the dam foundation and surface water sources (upstream and downstream), and location of the anomalous leakage outlets in the dam foundation. Limitations of the flow-field fitting method were complemented with resistivity logging to identify the internal erosion which had not yet developed into seepage pathways. The results of the flow-field fitting method and resistivity logging were consistent when compared with data provided by seismic tomography, borehole television, water injection test, and rock quality designation.

  6. Parametrization of the radiation induced leakage current increase of NMOS transistors

    CERN Document Server

    Backhaus, Malte

    2017-01-13

    The increase of the leakage current of NMOS transistors during exposure to ionizing radiation is known and well studied. Radiation hardness by design techniques have been developed to mitigate this effect and have been successfully used. More recent developments in smaller feature size technologies do not make use of these techniques due to their drawbacks in terms of logic density and requirement of dedicated libraries. During operation the resulting increase of the supply current is a serious challenge and needs to be considered during the system design. A simple parametrization of the leakage current of NMOS transistors as a function of total ionizing dose is presented. The parametrization uses a transistor transfer characteristics of the parasitic transistor along the shallow trench isolation to describe the leakage current of the nominal transistor. Together with a parametrization of the number of positive charges trapped in the silicon dioxide and number of activated interface traps in the silicon to si...

  7. Analyses on the measurement of leakage currents in CdZnTe radiation detectors

    International Nuclear Information System (INIS)

    Mescher, M.J.; Hoburg, J.F.; Schlesinger, T.E.; James, R.B.

    1999-01-01

    Models that place design constraints on devices which are used to measure the leakage currents in high-resistivity semiconductor materials are presented. If these design constraints are met, these models can then be used to quantitatively predict the surface sheet resistance of devices which are dominated by surface leakage currents. As a result, a means is provided to directly compare passivation techniques which are developed to decrease surface leakage currents. Furthermore, these models illustrate the necessity for inclusion of relevant geometrical data on sample size and shape and electrode configuration when reporting results of surface passivation techniques. These models specifically examine the case where a dc potential is applied across two electrodes on the surface of a semiconductor substrate which has a surface layer with lower resistivity than the bulk material. The authors describe several of the more common configurations used in analyzing passivation techniques for compounds of Cd 1-x Zn x Te (CZT) used for room-temperature radiation detection

  8. The Analysis and Comparison of Leakage Inductance in Different Winding Arrangements for Planar Transformer

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Thomsen, Ole Cornelius; Andersen, Michael Andreas E.

    2009-01-01

    The coupling of the windings can be easily increased by using multiply stacked planar windings connection. Interleaving is a well-known technique used to reduce leakage inductance and minimize high-frequency winding losses. The paper aims to analyze leakage inductance based on magneto motive force...

  9. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology

    OpenAIRE

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective...

  10. Acoustic emission monitoring of leakage through seal-plug in PHWR systems

    Energy Technology Data Exchange (ETDEWEB)

    Jha, S K; Badgujar, B P; Goswami, G L [Bhabha Atomic Research Centre, Bombay (India). Atomic Fuels Div.; Patel, R J; Bhattacharya, S; Agrawal, R G [Bhabha Atomic Research Centre, Mumbai (India). Refuelling Technology Division

    1994-12-31

    Acoustic Emission (AE) technique is being developed as an in-service inspection tool for monitoring the leakage through seal-plugs in Pressurised Heavy Water Reactors (PHWRs). Time as well as frequency domain analysis have been utilised during the experiment carried out at Bhabha Atomic Research Centre (BARC) using test set up simulating the pressure and temperature conditions. The work involved were to determine the temperature profile on end-fitting, effect of pressure and temperature on leakage etc. This paper discusses various relationships like signal-level vs. pressure, frequency spectrum of signal, signal-level vs. leakage based on the above experimental work. (author). 4 refs., 6 figs.

  11. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  12. Soil solution extraction techniques for microbial ecotoxicity testing: a comparative evaluation.

    Science.gov (United States)

    Tiensing, T; Preston, S; Strachan, N; Paton, G I

    2001-02-01

    The suitability of two different techniques (centrifugation and Rhizon sampler) for obtaining the interstitial pore water of soil (soil solution), integral to the ecotoxicity assessment of metal contaminated soil, were investigated by combining chemical analyses and a luminescence-based microbial biosensor. Two different techniques, centrifugation and Rhizon sampler, were used to extract the soil solution from Insch (a loamy sand) and Boyndie (a sandy loam) soils, which had been amended with different concentrations of Zn and Cd. The concentrations of dissolved organic carbon (DOC), major anions (F- , CI-, NO3, SO4(2-)) and major cations (K+, Mg2+, Ca2+) in the soil solutions varied depending on the extraction technique used. Overall, the concentrations of Zn and Cd were significantly higher in the soil solution extracted using the centrifugation technique compared with that extracted using the Rhizon sampler technique. Furthermore, the differences observed between the two extraction techniques depended on the type of soil from which the solution was being extracted. The luminescence-based biosensor Escherichia coli HB101 pUCD607 was shown to respond to the free metal concentrations in the soil solutions and showed that different toxicities were associated with each soil, depending on the technique used to extract the soil solution. This study highlights the need to characterise the type of extraction technique used to obtain the soil solution for ecotoxicity testing in order that a representative ecotoxicity assessment can be carried out.

  13. Modeling the leakage of LCD displays with local backlight for quality assessment

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.

    2014-01-01

    The recent technique of local backlight dimming has a significant impact on the quality of images displayed with a LCD screen with LED local dimming. Therefore it represents a necessary step in the quality assessment chain, independently from the other processes applied to images. This paper...... investigates the modeling of one of the major spatial artifacts produced by local dimming: leakage. Leakage appears in dark areas when the backlight level is too high for LC cells to block sufficiently and the final displayed brightness is higher than it should. A subjective quality experiment was run...... on videos displayed on LCD TV with local backlight dimming viewed from a 0° and 15° angles. The subjective results are then compared objective data using different leakage models: constant over the whole display or horizontally varying and three leakage factor (no leakage, measured at 0° and 15...

  14. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  15. Leakage of pressurized gases through unlined concrete containment structures

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.

    1983-01-01

    Eight reinforced concrete specimens were fabricated and subjected to tensile membrane forces and air pressure to study the air leakage characteristics in cracked reinforced concrete members. A mathematical expression for the rate of pressurized air flowing through an idealized crack is presented. The mathematical expression is refined by using the experimental data to describe the air flow rate through any given crack pattern. Graphical charts are also presented for the calculation of the air leakage rate through concrete cracks. The concept of equivalent crack width for a given crack pattern is introduced. The mathematical expression and graphical charts are modified to include this equivalent crack width concept. The proposed technique is applicable for the prediction of the leakage from concrete containment structures or any similar structures due to high internal pressure sufficient to initiate cracking. (orig.)

  16. Regulatory concerns for leakage testing of packagings with three O-ring closure seals

    International Nuclear Information System (INIS)

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-01-01

    The American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) provides guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements and also provides guidance in determining appropriate acceptance criteria. Recent radioactive packagings designs have incorporated three O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results of leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can be caused in two ways, a large leakage in the containment seal or leakage in the inner seal. This paper will describe the problem together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packagings before a particular packaging design can be certified for transport

  17. Surface CO2 leakage during the first shallow subsurface CO2 release experiment

    OpenAIRE

    Lewicki, J.L.; Oldenburg, C.; Dobeck, L.; Spangler, L.

    2008-01-01

    A new field facility was used to study CO2 migration processes and test techniques to detect and quantify potential CO2 leakage from geologic storage sites. For 10 days starting 9 July 2007, and for seven days starting 5 August 2007, 0.1 and 0.3 t CO2 d-1, respectively, were released from a ~;100-m long, sub-water table (~;2.5-m depth) horizontal well. The spatio-temporal evolution of leakage was mapped through repeated grid measurements of soil CO2 flux (FCO2). The surface leakage onset...

  18. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  19. clay nanocomposite by solution intercalation technique

    Indian Academy of Sciences (India)

    Polymer–clay nanocomposites of commercial polystyrene (PS) and clay laponite were prepared via solution intercalation technique. Laponite was modified suitably with the well known cationic surfactant cetyltrimethyl ammonium bromide by ion-exchange reaction to render laponite miscible with hydrophobic PS.

  20. Management and prevention of chylous leakage after laparoscopic lymphadenectomy.

    Science.gov (United States)

    Han, L-P; Zhang, H-M; Abha, H-D; Liu, T; Zhang, X-P

    2014-01-01

    To investigate the development and management of chylous leakage after laparoscopic retroperitoneal lymphadenectomy. From July 2006 to September 2013, 13 cases of chylous leakage after the laparoscopic lymphadenectomy (6 cases of renal cell carcinoma, 4 cases of gastric cancer, 2 cases of ovarian cancer, 1 case of endometrial cancer) were studied to analyze the occurrence, development and management of chylous leakage. In 3 cases (2 cases of renal cell carcinoma, 1 case of gastric cancer) massive amount of milky fluid drainage was be seen after the first two days post operation. Dietary intervention, TPN (total parenteral nutrition), somatostatin therapy, maintenance of continuous drainage helped to successfully manage the condition in about 1 month duration. In the remaining 10 cases, chylous leakage appeared after restoring normal diet. Managed with changes in diet and maintenance of unobstructed drainage, they were cured in about 2 weeks after treatment. There was significant reduction in drain output, ultrasonography did not reveal presence of free fluid collection in abdomen, and the patients were in good condition without signs and symptoms of infections. Chylous leakage is a rare complication of retroperitoneal lymph node dissection. Surgeons should be familiar with laparoscopic techniques, relevant anatomy and be aware of the fact that the effect of CO2 pressure and use of ultrasonic knife to occlude the lymphatic vessel can transiently block the leakage making the surgeon overlook them. Routine placement of indwelling drainage tube, immediate diagnosis, dietary modification, TPN, somatostatin and drainage are the modalities of conservative management.

  1. Use of isotopes and geophysical techniques in studying dam leakage-case of the Afamia dams Syria

    International Nuclear Information System (INIS)

    Kattan, Z.; Naser, R.; Al-Fares, W.; Kadkoy, N.; Sbenati, M.R.; Al-Hilal, M.; Sleman, I.; Al-Ali, A.

    2011-08-01

    Different techniques such as: hydrochemistry, environmental isotopes, radon and geophysical surveys have been applied all together in investigating the water leakages from the Afamia (A, B and C) dams during the period 2006-2008. Groundwater movement in this area shows the existence of two major discharge cones or sinks in the vicinity of B and C reservoirs. This movement suggests a probable vertical leaking and interconnection between the shallow Neogene aquifer and the deeper Karstified water bearing system of the Upper Cretaceous. Spatial distribution patterns of major ions in the groundwater provided comprehensive arguments for the existence of an active dissolution zone of calcareous rocks at a depth of about 45 m below the land surface, facilitating hence the vertical penetration of stored surface water towards the Cretaceous aquifer. The remarkable contrasts in stable isotope compositions between the depleted and highly enriched waters nearby the B reservoir provide another support for water leaks by vertical penetration beneath or very close to the B dam body. The high radon values in the soils, linearly distributed along some tectonic lineaments, may indicate the usefulness of radon method for tracing and mapping unknown faults. Application of some selected geophysical methods (electromagnetic survey, vertical geoelectric sounding and tomography plates) revealed the presence of alternating lithological heterogeneity between permeable and impermeable layers, which may lead to subhorizontal infiltration through the geological formations of the basin. Vertical leakage which could take place in certain locations via existing faults and karst and fractures that hit the main valley may pass through the dam lake. This structure is most likely causing hydraulic connections between the superficial Neogene deposits and the underlying Cretaceous fractured and permeable carbonates rocks. The presence of clayey and silty zones, mostly of high electrical conductivity

  2. Cerebrospinal fluid leakage. Indications, technique and results of treatment with a blood patch

    International Nuclear Information System (INIS)

    Gottschalk, A.

    2015-01-01

    In most cases cerebrospinal fluid (CSF) leaks are iatrogenic and caused by medical interventions, such as lumbar puncture, peridural anesthesia and surgical interventions on the spine, However, spontaneous cerebral hypotension is currently detected more frequently due to improvements in diagnostic possibilities but often the cause cannot be clarified with certainty. There are various diagnostic tools for confirming the diagnosis and searching for the site of CSF leakage, such as postmyelography computed tomography (postmyelo-CT), indium 111 radioisotope cisternography and (myelo) magnetic resonance imaging (MRI), which show different sensitivities. In accordance with own experience native MRI with fat-saturated T2-weighted sequences is often sufficient for diagnosing CSF leakage and the site. For the remaining cases an additional postmyelo-CT or alternatively myelo-MRI is recommended. In some patients with spontaneous cranial hypotension multiple CSF leaks are found at different spinal levels. The main symptom in most cases is an orthostatic headache. While post-puncture syndrome is self-limiting in many cases, spontaneous CSF leakage usually requires blood patch therapy. A lumbar blood patch can be safely carried out under guidance by fluoroscopy. In the case of a cervical or dorsal blood patch, CT guidance is recommended, which ensures epidural application of the blood patch and minimizes the risk of damaging the spinal cord. Despite a high success rate at the first attempt with a blood patch of up to 85 %, some cases require repeating the blood patch. A targeted blood patch of a CSF leak should generally be favoured over a blindly placed blood patch; nevertheless, if a CSF leak cannot be localized by CT or MRI a therapeutic attempt with a lumbar blood patch can be carried out. After a successful blood patch intracranial hygromas and pachymeningeal enhancement in the head show fast regression; however, epidural hygromas of the spine can persist for a period of

  3. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  4. Quantification of leakage from large unilamellar lipid vesicles by fluorescence correlation spectroscopy

    DEFF Research Database (Denmark)

    Kristensen, Kasper; Henriksen, Jonas Rosager; Andresen, Thomas Lars

    2014-01-01

    Fluorescence correlation spectroscopy (FCS) is a powerful experimental technique that in recent years has found numerous applications for studying biological phenomena. In this article, we scrutinize one of these applications, namely, FCS as a technique for studying leakage of fluorescent molecul...

  5. The Impact of Gas Turbine Component Leakage Fault on GPA Performance Diagnostics

    Directory of Open Access Journals (Sweden)

    E. L. Ntantis

    2016-01-01

    Full Text Available The leakage analysis is a key factor in determining energy loss from a gas turbine. Once the components assembly fails, air leakage through the opening increases resulting in a performance loss. Therefore, the performance efficiency of the engine cannot be reliably determined, without good estimates and analysis of leakage faults. Consequently, the implementation of a leakage fault within a gas turbine engine model is necessary for any performance diagnostic technique that can expand its diagnostics capabilities for more accurate predictions. This paper explores the impact of gas turbine component leakage fault on GPA (Gas Path Analysis Performance Diagnostics. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different component fault cases. Conclusively, to improve the reliability of the diagnostic results, a leakage fault analysis of the implemented faults is made. The diagnostic tool used to deal with the analysis of the gas turbine component implemented faults is a model-based method utilizing a non-linear GPA.

  6. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  7. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology.

    Science.gov (United States)

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.

  8. Solution chemistry techniques in SYNROC preparation

    International Nuclear Information System (INIS)

    Dosch, R.G.; Lynch, A.W.

    1981-07-01

    Investigations of titanate-based ceramic forms for radioactive waste immobilization are underway at Sandia National Laboratories (SNLA) and at Lawrence Livermore National Laboratory (LLNL). Although the waste forms differ as to overall product composition, the waste-containing phases in both ceramic products have similar crystalline structure types. These include metallic phases along with oxides with structure types of the mineral analogues perovskite, zirconolite, and hollandite. Significant differences also exist in the area of processing. More conventional ceramic processing methods are used at LLNL to produce SYNROC while solution chemistry techniques involving metal alkoxide chemistry and ion exchange have been developed at SNLA to prepare calcium titanate-based waste ceramics. The SNLA techniques were recently modified and applied to producing SYNROC (compositions C and D) as part of an interlaboratory information exchange between SNLA and LLNL. This report describes the methods used in preparing SYNROC including the solution interaction, and hot-pressing methods used to obtain fully dense SYNROC monoliths

  9. Management of cerebrospinal fluid leakage after anterior decompression for ossification of posterior longitudinal ligament in the thoracic spine: the utilization of a volume-controlled pseudomeningocele.

    Science.gov (United States)

    Cho, Ji Young; Chan, Chee Keong; Lee, Sang-Ho; Choi, Won-Chul; Maeng, Dae Hyeon; Lee, Ho-Yeon

    2012-06-01

    Retrospective review To determine the efficacy of management of cerebrospinal fluid (CSF) leakage after the anterior thoracic approach. CSF leakage after incidental durotomy commonly occurs after anterior thoracic ossification of posterior longitudinal ligament (OPLL) surgery. Pseudomeningocele will invariably form under such circumstances. Among them, uncontrolled CSF leakage with a fistulous condition is problematic. As a solution, we have managed these durotomies with chest drains alone without any CSF drainage by the concept of a "volume-controlled pseudomeningocele." Between 2001 and 2009, CSF leakage occurred in 26 patients (37.7%) of the total 69 patients who underwent anterior decompression for thoracic OPLL. In the initial 11 cases, subarachnoid drainage was utilized as an augmentive measure in combination with chest tube drainage in the postoperative period (group A). In the subsequent 15 cases, the durotomy was managed in a similar manner but in the absence of any subarachnoid drainage (group B). Various parameters such as the duration of postoperative hospital stay, clinical outcome score, drainage output, resolution of CSF leakage, complications, and additional surgery performed were analyzed and compared between the 2 groups. A resolution of the CSF leakage grading system was also proposed for the residual pseudomeningocele that formed in each group. There were statistically no significant differences in the outcome parameters between the 2 groups and also in patients with grade I or grade II residual pseudomeningocele of the new grading system. Two complications occurred in group A. No reexploration for persistent CSF leakage was required in both groups. CSF leakage managed with controlled chest tube drainage can produce a comparable result with those with additional subarachnoid drainage when watertight dural repair is impossible. The concept of controlled pseudomeningocele may be a useful and practical technique for the treatment of CSF leakage

  10. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    Directory of Open Access Journals (Sweden)

    Kazeem B. Adedeji

    2017-10-01

    Full Text Available Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s of the network and the exact leaking pipelines connected to this segment(s where higher background leakage outflow occurs is a challenging task. Background leakage concerns the outflow from small cracks or deteriorated joints. In addition, because they are diffuse flow, they are not characterised by quick pressure drop and are not detectable by measuring instruments. Consequently, they go unreported for a long period of time posing a threat to water loss volume. Most of the existing research focuses on the detection and localisation of burst type leakages which are characterised by a sudden pressure drop. In this work, an algorithm for detecting and estimating background leakage in water distribution networks is presented. The algorithm integrates a leakage model into a classical WDN hydraulic model for solving the network leakage flows. The applicability of the developed algorithm is demonstrated on two different water networks. The results of the tested networks are discussed and the solutions obtained show the benefits of the proposed algorithm. A noteworthy evidence is that the algorithm permits the detection of critical segments or pipes of the network experiencing higher leakage outflow and indicates the probable pipes of the network where pressure control can be performed. However, the possible position of pressure control elements along such critical pipes will be addressed in future work.

  11. Effect of gamma radiation on the leakage of substances from lymphocytes. In vitro study using immuno-precipitation techniques in gel medium

    International Nuclear Information System (INIS)

    Dubos, M.; Nguyen, T.-L.; Drouet, J.; Goujon, P.

    In vitro effect of a 5000 R irradiation on rat blood lymphocytes was studied during several days in surviving cell suspensions, at various incubation temperature. Immunochemical analysis in agarose gel, using the simple diffusion technique, exhibited the leakage of two groups of antigenic compounds, from lymphocytes. The first group compounds seemed to be periodical renewal products of surface cell membrane elements, common to lymphocytes and erythrocytes; irradiation increased their release. A correlation was established between the second group compounds and cell metabolism and these compounds seemed to be enzymes of cytolitic origin [fr

  12. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    Science.gov (United States)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  13. Improving off-state leakage characteristics for high voltage AlGaN/GaN-HFETs on Si substrates

    Science.gov (United States)

    Moon, Sung-Woon; Twynam, John; Lee, Jongsub; Seo, Deokwon; Jung, Sungdal; Choi, Hong Goo; Shim, Heejae; Yim, Jeong Soon; Roh, Sungwon D.

    2014-06-01

    We present a reliable process and design technique for realizing high voltage AlGaN/GaN hetero-junction field effect transistors (HFETs) on Si substrates with very low and stable off-state leakage current characteristics. In this work, we have investigated the effects of the surface passivation layer, prepared by low pressure chemical vapor deposition (LPCVD) of silicon nitride (SiNx), and gate bus isolation design on the off-state leakage characteristics of metal-oxide-semiconductor (MOS) gate structure-based GaN HFETs. The surface passivated devices with gate bus isolation fully surrounding the source and drain regions showed extremely low off-state leakage currents of less than 20 nA/mm at 600 V, with very small variation. These techniques were successfully applied to high-current devices with 80-mm gate width, yielding excellent off-state leakage characteristics within a drain voltage range 0-700 V.

  14. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  15. Superconducting coil configurations, with low flux leakage, for energy storage

    International Nuclear Information System (INIS)

    Vincent-Viry, O.; Mailfert, A.; Trassart, D.

    2001-01-01

    This paper presents two original types of SMES structures for energy storage. These two groups of SMES structures proceeded from an ideal structure: the full toroid, are modeled by the use of purely surface current densities. Their main advantage is to present no flux leakage, they give then satisfactory solution to the problem of energy storage. (orig.)

  16. Microvascular dysfunction with increased vascular leakage response in mice systemically exposed to arsenic.

    Science.gov (United States)

    Chen, Shih-Chieh; Huang, Shin-Yin; Lu, Chi-Yu; Hsu, Ya-Hung; Wang, Dean-Chuan

    2014-09-01

    The mechanisms underlying cardiovascular disease induced by arsenic exposure are not completely understood. The objectives of this study were to investigate whether arsenic-fed mice have an increased vascular leakage response to vasoactive agents and whether enhanced type-2 protein phosphatase (PP2A) activity is involved in mustard oil-induced leakage. ICR mice were fed water or sodium arsenite (20 mg/kg) for 4 or 8 weeks. The leakage response to vasoactive agents was quantified using the Evans blue (EB) technique or vascular labeling with carbon particles. Increased EB leakage and high density of carbon-labeled microvessels were detected in arsenic-fed mice treated with mustard oil. Histamine induced significantly higher vascular leakage in arsenic-fed mice than in water-fed mice. Pretreatment with the PP2A inhibitor okadaic acid or the neurokinin 1 receptor (NK1R) blocker RP67580 significantly reduced mustard oil-induced vascular leakage in arsenic-fed mice. The protein levels of PP2Ac and NK1R were similar in both groups. PP2A activity was significantly higher in the arsenic-fed mice compared with the control group. These findings indicate that microvessels generally respond to vasoactive agents, and that the increased PP2A activity is involved in mustard oil-induced vascular leakage in arsenic-fed mice. Arsenic may initiate endothelial dysfunction, resulting in vascular leakage in response to vasoactive agents.

  17. Analysis of Gas Leakage and Current Loss of Solid Oxide Fuel Cells by Screen Printing

    DEFF Research Database (Denmark)

    Jia, Chuan; Han, Minfang; Chen, Ming

    2017-01-01

    Two types of anode supported solid oxide fuel cell (SOFC) NiO-YSZ/YSZ/GDC/LSCF with the same structure and different manufacturing process were tested. Gas leakage was suspected for cells manufactured with screen printing technique. Effective leak current densities for both types of cells were...... calculated. Their performances of electrochemical impedance spectroscopy (EIS) were compared and distribution function of relaxation times (DRT) technique was also used to find the clue of gas leakage. Finally, thinning and penetrating holes were observed in electrolyte layer, which confirmed the occurrence...

  18. Leak testing of bubble-tight dampers using tracer gas techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); DuBois, L.J. [Commonwealth Edison, Zion, IL (United States); Fleming, K.M. [NCS Corporation, Columbus, OH (United States)] [and others

    1995-02-01

    Recently tracer gas techniques have been applied to the problem of measuring the leakage across an installed bubble-tight damper. A significant advantage of using a tracer gas technique is that quantitative leakage data are obtained under actual operating differential pressure conditions. Another advantage is that leakage data can be obtained using relatively simple test setups that utilize inexpensive materials without the need to tear ducts apart, fabricate expensive blank-off plates, and install test connections. Also, a tracer gas technique can be used to provide an accurate field evaluation of the performance of installed bubble-tight dampers on a periodic basis. Actual leakage flowrates were obtained at Zion Generating Station on four installed bubble-tight dampers using a tracer gas technique. Measured leakage rates ranged from 0.01 CFM to 21 CFM. After adjustment and subsequent retesting, the 21 CFM damper leakage was reduced to a leakage of 3.8 CFM. In light of the current regulatory climate and the interest in Control Room Habitability issues, imprecise estimates of critical air boundary leakage rates--such as through bubble-tight dampers--are not acceptable. These imprecise estimates can skew radioactive dose assessments as well as chemical contaminant exposure calculations. Using a tracer gas technique, the actual leakage rate can be determined. This knowledge eliminates a significant source of uncertainty in both radioactive dose and/or chemical exposure assessments.

  19. Ex vivo evaluation of coronal and apical microbial leakage of root canal - Filled with gutta-percha or Resilon/Epiphany root canal filling material

    Directory of Open Access Journals (Sweden)

    de Almeida-Gomes Fabio

    2010-01-01

    Full Text Available Objective: This ex vivo study compared coronal and apical microleakage of root canals filled with Resilon/Epiphany (RE or gutta-percha/Grossman sealer (GP, using either lateral condensation (LC or System B (SB technique. Materials and Methods: Specimens in eight experimental groups were obturated using the following materials and techniques: Groups 1 and 3 - GP and LC; groups 2 and 4 - GP and SB; groups 5 and 7 - RE and LC; groups 6 and 8 - RE and SB. Apical and coronal leakages were tested using bacterial methods. For coronal analysis, the number of days required for complete contamination of the root canals was recorded according to observation of the brain heart infusion broth turbidity for 15 weeks. For apical analysis, the teeth were cleaved and the leakage was measured at 30 days. Data were collected for each sample and analyzed statistically with the Chi-square and ANOVA tests. Results: Leakage was found in all groups. The difference between filling materials, obturation techniques, and median time of leakage was not statistically significant for coronal ( P=0.847 and apical ( P=0.5789 leakages. Conclusion: There were no differences between the different filling materials (gutta-percha/Grossman sealer and Resilon/Epiphany and obturation techniques (lateral condensation and system B technique in coronal or apical leakages.

  20. Time-windows-based filtering method for near-surface detection of leakage from geologic carbon sequestration sites

    Energy Technology Data Exchange (ETDEWEB)

    Pan, L.; Lewicki, J.L.; Oldenburg, C.M.; Fischer, M.L.

    2010-02-28

    We use process-based modeling techniques to characterize the temporal features of natural biologically controlled surface CO{sub 2} fluxes and the relationships between the assimilation and respiration fluxes. Based on these analyses, we develop a signal-enhancing technique that combines a novel time-window splitting scheme, a simple median filtering, and an appropriate scaling method to detect potential signals of leakage of CO{sub 2} from geologic carbon sequestration sites from within datasets of net near-surface CO{sub 2} flux measurements. The technique can be directly applied to measured data and does not require subjective gap filling or data-smoothing preprocessing. Preliminary application of the new method to flux measurements from a CO{sub 2} shallow-release experiment appears promising for detecting a leakage signal relative to background variability. The leakage index of ?2 was found to span the range of biological variability for various ecosystems as determined by observing CO{sub 2} flux data at various control sites for a number of years.

  1. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  2. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  3. Geochemical monitoring for detection of CO_{2} leakage from subsea storage sites

    Science.gov (United States)

    García-Ibáñez, Maribel I.; Omar, Abdirahman M.; Johannessen, Truls

    2017-04-01

    Carbon Capture and Storage (CCS) in subsea geological formations is a promising large-scale technology for mitigating the increases of carbon dioxide (CO2) in the atmosphere. However, detection and quantification of potential leakage of the stored CO2 remains as one of the main challenges of this technology. Geochemical monitoring of the water column is specially demanding because the leakage CO2 once in the seawater may be rapidly dispersed by dissolution, dilution and currents. In situ sensors capture CO2 leakage signal if they are deployed very close to the leakage point. For regions with vigorous mixing and/or deep water column, and for areas far away from the leakage point, a highly sensitive carbon tracer (Cseep tracer) was developed based on the back-calculation techniques used to estimate anthropogenic CO2 in the water column. Originally, the Cseep tracer was computed using accurate discrete measurements of total dissolved inorganic carbon (DIC) and total alkalinity (AT) in the Norwegian Sea to isolate the effect of natural submarine vents in the water column. In this work we assess the effect of measurement variables on the performance of the method by computing the Cseep tracer twice: first using DIC and AT, and second using partial pressure of CO2 (pCO2) and pH. The assessment was performed through the calculation of the signal to noise ratios (STNR). We found that the use of the Cseep tracer increases the STNR ten times compared to the raw measurement data, regardless of the variables used. Thus, while traditionally the pH-pCO2 pair generates the greatest uncertainties in the oceanic CO2 system, it seems that the Cseep technique is insensitive to that issue. On the contrary, the use of the pCO2-pH pair has the highest CO2 leakage detection and localization potential due to the fact that both pCO2 and pH can currently be measured at high frequency and in an autonomous mode.

  4. Leakage current-induced effects in the silicon microstrip and gas electron multiplier readout chain and their compensation method

    Science.gov (United States)

    Zubrzycka, W.; Kasinski, K.

    2018-04-01

    Leakage current flowing into the charge sensitive amplifier (CSA) is a common issue in many radiation detection systems as it can increase overall system noise, shift a DC baseline or even lead a recording channel to instability. The commonly known leakage current contributor is a detector, however other system components like wires or an input protection circuit may become a serious problem. Compensation of the leakage current resulting from the electrostatic discharge (ESD) protection circuit by properly sizing its components is possible only for a narrow temperature range. Moreover, the leakage current from external sources can be significantly larger. Many applications, especially High Energy Physics (HEP) experiments, require a fast baseline restoration for high input hit rates by applying either a low-value feedback resistor or a high feedback resistance combined with a pulsed reset circuit. Leakage current flowing in the feedback in conjunction with a large feedback resistance supplied with a pulsed reset results in a significant voltage offset between the CSA input and output which can cause problems (e.g. fake hits or instability). This paper shows an issue referred to the leakage current of the ESD protection circuit flowing into the input amplifier. The following analysis and proposed solution is a result of the time and energy readout ASIC project realization for the Compressed Baryonic Matter (CBM) experiment at FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. This chip is purposed to work with microstrip and gaseous detectors, with high average input pulses frequencies (250 kHit/s per channel) and the possibility to process input charge of both polarities. We present measurements of the test structure fabricated in UMC 180 nm technology and propose a solution addressing leakage current related issues. This work combines the leakage current compensation capabilities at the CSA level with high, controllable value of the amplifier

  5. Analysis of reverse gate leakage mechanism of AlGaN/GaN HEMTs with N2 plasma surface treatment

    Science.gov (United States)

    Liu, Hui; Zhang, Zongjing; Luo, Weijun

    2018-06-01

    The mechanism of reverse gate leakage current of AlGaN/GaN HEMTs with two different surface treatment methods are studied by using C-V, temperature dependent I-V and theoretical analysis. At the lower reverse bias region (VR >- 3.5 V), the dominant leakage current mechanism of the device with N2 plasma surface treatment is the Poole-Frenkel emission current (PF), and Trap-Assisted Tunneling current (TAT) is the principal leakage current of the device which treated by HCl:H2O solution. At the higher reverse bias region (VR current of the device with N2 plasma surface treatment is one order of magnitude smaller than the device which treated by HCl:H2O solution. This is due to the recovery of Ga-N bond in N2 plasma surface treatment together with the reduction of the shallow traps in post-gate annealing (PGA) process. The measured results agree well with the theoretical calculations and demonstrate N2 plasma surface treatment can reduce the reverse leakage current of the AlGaN/GaN HEMTs.

  6. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  7. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  8. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    Science.gov (United States)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  9. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  10. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  11. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  12. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  13. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  14. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun [Radiation Eng. Center, Shihung (Korea, Republic of); Lee, Dongbum [Academic Support Dept., Seoul (Korea, Republic of)

    2013-05-15

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  15. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    International Nuclear Information System (INIS)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun; Lee, Dongbum

    2013-01-01

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  16. The Leakage Current Improvement of a Ni-Silicided SiGe/Si Junction Using a Si Cap Layer and the PAI Technique

    International Nuclear Information System (INIS)

    Chang Jian-Guang; Wu Chun-Bo; Ji Xiao-Li; Ma Hao-Wen; Yan Feng; Shi Yi; Zhang Rong

    2012-01-01

    We investigate the leakage current of ultra-shallow Ni-silicided SiGe/Si junctions for 45 nm CMOS technology using a Si cap layer and the pre-amorphization implantation (PAI) process. It is found that with the conventional Ni silicide method, the leakage current of a p + (SiGe)—n(Si) junction is large and attributed to band-to-band tunneling and the generation-recombination process. The two leakage contributors can be suppressed quite effectively when a Si cap layer is added in the Ni silicide method. The leakage reduction is about one order of magnitude and could be associated with the suppression of the agglomeration of the Ni germano-silicide film. In addition, the PAI process after the application of a Si cap layer has little effect on improving the junction leakage but reduces the sheet resistance of the silicide film. As a result, the novel Ni silicide method using a Si cap combined with PAI is a promising choice for SiGe junctions in advanced technology. (cross-disciplinary physics and related areas of science and technology)

  17. Global exponential convergence of neutral-type Hopfield neural networks with multi-proportional delays and leakage delays

    International Nuclear Information System (INIS)

    Xu, Changjin; Li, Peiluan

    2017-01-01

    This paper is concerned with a class of neutral-type Hopfield neural networks with multi-proportional delays and leakage delays. Using the differential inequality theory, a set of sufficient conditions which guarantee that all solutions of neutral-type Hopfield neural networks with multi-proportional delays and leakage delays converge exponentially to zero vector are derived. Computer simulations are carried out to verify our theoretical findings. The obtained results of this paper are new and complement some previous studies.

  18. Systematic review of methods to predict and detect anastomotic leakage in colorectal surgery.

    Science.gov (United States)

    Hirst, N A; Tiernan, J P; Millner, P A; Jayne, D G

    2014-02-01

    Anastomotic leakage is a serious complication of gastrointestinal surgery resulting in increased morbidity and mortality, poor function and predisposing to cancer recurrence. Earlier diagnosis and intervention can minimize systemic complications but is hindered by current diagnostic methods that are non-specific and often uninformative. The purpose of this paper is to review current developments in the field and to identify strategies for early detection and treatment of anastomotic leakage. A systematic literature search was performed using the MEDLINE, Embase, PubMed and Cochrane Library databases. Search terms included 'anastomosis' and 'leak' and 'diagnosis' or 'detection' and 'gastrointestinal' or 'colorectal'. Papers concentrating on the diagnosis of gastrointestinal anastomotic leak were identified and further searches were performed by cross-referencing. Computerized tomography CT scanning and water-soluble contrast studies are the current preferred techniques for diagnosing anastomotic leakage but suffer from variable sensitivity and specificity, have logistical constraints and may delay timely intervention. Intra-operative endoscopy and imaging may offer certain advantages, but the ability to predict anastomotic leakage is unproven. Newer techniques involve measurement of biomarkers for anastomotic leakage and have the potential advantage of providing cheap real-time monitoring for postoperative complications. Current diagnostic tests often fail to diagnose anastomotic leak at an early stage that enables timely intervention and minimizes serious morbidity and mortality. Emerging technologies, based on detection of local biomarkers, have achieved proof of concept status but require further evaluation to determine whether they translate into improved patient outcomes. Further research is needed to address this important, yet relatively unrecognized, area of unmet clinical need. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain

  19. Intelligent Pressure Management to Reduce Leakage in Urban Water Supply Networks, A Case Study of Sarafrazan District, Mashhad

    OpenAIRE

    Mohammad Soltani Asl; Mahmoud Faghfour Maghrebi

    2009-01-01

    Water losses are inevitable in urban water distribution systems. The two approaches adopted nowadays to combat this problem include management of hydraulic parameters such as pressure and leakage detection in the network. Intellitgent pressure management is a suitable technique for controlling leakage and reducing damages due to high operating pressures in a network. This paper aims to investigate the effects of pressure reduction on leakage. The EPANET 2.10 software is used to simulate the w...

  20. Leakage current of amorphous silicon p-i-n diodes made by ion shower doping

    International Nuclear Information System (INIS)

    Kim, Hee Joon; Cho, Gyuseong; Choi, Joonhoo; Jung, Kwan-Wook

    2002-01-01

    In this letter, we report the leakage current of amorphous silicon (a-Si:H) p-i-n photodiodes, of which the p layer is formed by ion shower doping. The ion shower doping technique has an advantage over plasma-enhanced chemical vapor deposition (PECVD) in the fabrication of a large-area amorphous silicon flat-panel detector. The leakage current of the ion shower diodes shows a better uniformity within a 30 cmx40 cm substrate than that of the PECVD diodes. However, it shows a higher leakage current of 2-3 pA/mm 2 at -5 V. This high current originates from the high injection current at the p-i junction

  1. Characterization of aqueous silver nitrate solutions for leakage tests

    Directory of Open Access Journals (Sweden)

    José Ferreira Costa

    2011-06-01

    Full Text Available OBJECTIVE: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated. MATERIAL AND METHODS: A digital pHmeter was used for measuring the pH of the solutions prepared with three types of water (purified, deionized or distilled and three brands of silver nitrate salt (Merck, Synth or Cennabras at 0, 1, 2, 24, 48, 72, 96 and 168 h after preparation, and storage in transparent or dark bottles. Ionic silver was assayed according to the post-preparation times (2, 24, 48, 72, 96, 168 h and concentrations (1, 5, 25, 50% of solutions by atomic emission spectrometry. For each sample of each condition, three readings were obtained for calculating the mean value. Class V cavities were prepared with enamel margins on primary and permanent teeth and restored with the adhesive systems OptiBond FL or OptiBond SOLO Plus SE and the composite resin Filtek Z-250. After nail polish coverage, the permanent teeth were immersed in 25% or 50% AgNO3 solution and the primary teeth in 5% or 50% AgNO3 solutions for microleakage evaluation. ANOVA and the Tukey's test were used for data analyses (α=5%. RESULTS: The mean pH of the solutions ranged from neutral to alkaline (7.9±2.2 to 11.8±0.9. Mean ionic silver content differed depending on the concentration of the solution (4.75±0.5 to 293±15.3 ppm. In the microleakage test, significant difference was only observed for the adhesive system factor (p=0.000. CONCLUSIONS: Under the tested experimental conditions and based on the obtained results, it may be concluded that the aqueous AgNO3 solutions: have neutral/alkaline pH and service life of up to 168 h; the level of ionic silver is proportional to the concentration of the solution; even at 5% concentration, the solutions were

  2. Theoretical investigation of metal magnetic memory testing technique for detection of magnetic flux leakage signals from buried defect

    Science.gov (United States)

    Xu, Kunshan; Qiu, Xingqi; Tian, Xiaoshuai

    2018-01-01

    The metal magnetic memory testing (MMMT) technique has been extensively applied in various fields because of its unique advantages of easy operation, low cost and high efficiency. However, very limited theoretical research has been conducted on application of MMMT to buried defects. To promote study in this area, the equivalent magnetic charge method is employed to establish a self-magnetic flux leakage (SMFL) model of a buried defect. Theoretical results based on the established model successfully capture basic characteristics of the SMFL signals of buried defects, as confirmed via experiment. In particular, the newly developed model can calculate the buried depth of a defect based on the SMFL signals obtained via testing. The results show that the new model can successfully assess the characteristics of buried defects, which is valuable in the application of MMMT in non-destructive testing.

  3. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  4. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  5. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  6. [Effect of carbamide peroxide bleaching agents on micro-leakage of composite resin interface in vitro].

    Science.gov (United States)

    Wang, Xiao-ling; Xu, Juan; Zhao, Xin-yi; He, Hui-ming

    2011-01-01

    To evaluate the effect of carbamide peroxide (CP) bleaching agents at different concentrations and with different carriers on the micro-leakage of composite resin interface. Class V cavity (2 mm in diameter and 2 mm in depth) preparations were made at the enamelo-cemental junction on the buccal and lingual surfaces of 35 extracted human premolars. The cavities were filled with hybrid composite resin. The teeth were stored for 24 h in distilled water at 37 degrees celsius; before thermocyling for 500 times between 5 and 55 degrees celsius;. The teeth were then randomly assigned into 7 groups, and in groups 1-6, the bleaching gels containing 10% or 20% of CP were applied on the buccal and lingual surface of the teeth for two weeks (6-8 h/day, 37 degrees celsius;, 100% relative humidity) using Carbopol, PVP or Poloxamer as the thickening carriers, respectively. The seventh group served as the control without bleaching treatment. Nail polish was applied to the surface of the tooth, and all the teeth were immersed in ammoniacal silver nitrate solution followed by developing solution. The teeth were finally sectioned through the midline of the restoration and observed under stereomicroscope. SEM micrographs were also made to observe the interface. With the same bleaching agent, the micro-leakage in the gingival wall was slightly greater than in the occlusive wall, but the difference was not significant. Only 20% CP with Poloxamer as the thickening agent significantly increased the leakage of dentine-resin composite interface, and 10% and 20% CP with Carbopol or PVP as the thickening agents and 10% CP with Poloxamer produced minimal effects on filling the micro-leakage. Thickening carriers and the concentration of CP (20% or below) have no significant effect on micro-leakage of composite resin.

  7. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  8. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  9. Exploration of polyelectrolytes as draw solutes in forward osmosis processes

    KAUST Repository

    Ge, Qingchun

    2012-03-01

    The development of the forward osmosis (FO) process has been constrained by the slow development of appropriate draw solutions. Two significant concerns related to draw solutions are the draw solute leakage and intensiveenergy requirement in recycling draw solutes after the FO process. FO would be much attractive if there is no draw solute leakage and the recycle of draw solutes is easy and economic. In this study, polyelectrolytes of a series of polyacrylic acid sodium salts (PAA-Na), were explored as draw solutes in the FO process. The characteristics of high solubility in water and flexibility in structural configuration ensure the suitability of PAA-Na as draw solutes and their relative ease in recycle through pressure-driven membrane processes. The high water flux with insignificant salt leakage in the FO process and the high salt rejection in recycle processes reveal the superiority of PAA-Na to conventional ionic salts, such as NaCl, when comparing their FO performance via the same membranes. The repeatable performance of PAA-Na after recycle indicates the absence of any aggregation problems. The overall performance demonstrates that polyelectrolytes of PAA-Na series are promising as draw solutes, and the new concept of using polyelectrolytes as draw solutes in FO processes is applicable. © 2011 Elsevier Ltd.

  10. Phosphate dosing of mains water : novel approaches to water loss reduction through leakage detection and policy [abstract

    OpenAIRE

    Ascott, M.J.; Gooddy, D.C.; Lapworth, D.J.; Stuart, M.E.

    2016-01-01

    Detection and t racing of leakage in the environment are essential component s of water loss reduction strategies. Industry standard techniques for tracing leaks include analysis of chlorine and trihalomethane concentrations, but levels of these determinands can fall belo w detection limits due to their volatile nature 1 . Consequently additional tools to trace leakage in the environment are a useful step ...

  11. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  12. [Nuclear medicine diagnosis of pulmonary capillary protein leakage].

    Science.gov (United States)

    Creutzig, H; Sturm, J A; Schober, O; Nerlich, M L; Kant, C J

    1984-10-01

    Pulmonary extravascular albumin extravasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation of abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques.

  13. Procedure to carry out leakage test in beta radiation sealed sources emitters of 90Sr/90Y

    International Nuclear Information System (INIS)

    Alvarez R, J. T.

    2010-09-01

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D w ; these applicators, basically are emitter sealed sources of pure beta radiation of 90 Sr / 90 Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  14. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  15. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  16. Advantages of gadobenate dimeglumine-enhanced MR cholangiography in the diagnosis of post-liver transplant bile leakage.

    Science.gov (United States)

    Fontarensky, M; Montoriol, P-F; Buc, E; Poincloux, L; Petitcolin, V; Da Ines, D

    2013-04-01

    To assess the value of magnetic resonance cholangiography with gadobenate dimeglumine (Gd-BOPTA) where there is a suspicion of bile leakage in the post-liver transplant patient. Eight patients who had undergone a liver transplant underwent 14 MR cholangiograms, five of whom presented bile leakage while the other three had no biliary system complications. The results were compared to conventional bile duct opacification (by endoscopy or t-tube cholangiogram). The analysis covered whether there was opacification of the common bile duct and intrahepatic bile ducts on T1-weighted sequences after an injection of Gd-BOPTA on delayed biliary excretion phase sequences that were carried out on average 74 min after the injection. Enhancing perihepatic collections were also taken into account. Opacification of the bile ducts on delayed-phase MR cholangiogram sequences was always seen in the absence of bile leakage, and was never found when leakage was present. Enhancing perihepatic collections pointed to bile leakage every time. Gd-BOPTA-enhanced MR cholangiography is a simple and non-invasive technique for detecting bile leakage in the post-liver transplant patient. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  18. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  19. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  20. Prevention of Information Leakage by Photo-Coupling in Smart Card

    Science.gov (United States)

    Shen, Sung-Shiou; Chiu, Jung-Hui

    Advances in smart card technology encourages smart card use in more sensitive applications, such as storing important information and securing application. Smart cards are however vulnerable to side channel attacks. Power consumption and electromagnetic radiation of the smart card can leak information about the secret data protected by the smart card. Our paper describes two possible hardware countermeasures that protect against side channel information leakage. We show that power analysis can be prevented by adopting photo-coupling techniques. This method involves the use of LED with photovoltaic cells and photo-couplers on the power, reset, I/O and clock lines of the smart card. This method reduces the risk of internal data bus leakage on the external data lines. Moreover, we also discuss the effectiveness of reducing electromagnetic radiation by using embedded metal plates.

  1. Pulsed magnetic flux leakage method for hairline crack detection and characterization

    Science.gov (United States)

    Okolo, Chukwunonso K.; Meydan, Turgut

    2018-04-01

    The Magnetic Flux leakage (MFL) method is a well-established branch of electromagnetic Non-Destructive Testing (NDT), extensively used for evaluating defects both on the surface and far-surface of pipeline structures. However the conventional techniques are not capable of estimating their approximate size, location and orientation, hence an additional transducer is required to provide the extra information needed. This research is aimed at solving the inevitable problem of granular bond separation which occurs during manufacturing, leaving pipeline structures with miniature cracks. It reports on a quantitative approach based on the Pulsed Magnetic Flux Leakage (PMFL) method, for the detection and characterization of the signals produced by tangentially oriented rectangular surface and far-surface hairline cracks. This was achieved through visualization and 3D imaging of the leakage field. The investigation compared finite element numerical simulation with experimental data. Experiments were carried out using a 10mm thick low carbon steel plate containing artificial hairline cracks with various depth sizes, and different features were extracted from the transient signal. The influence of sensor lift-off and pulse width variation on the magnetic field distribution which affects the detection capability of various hairline cracks located at different depths in the specimen is explored. The findings show that the proposed technique can be used to classify both surface and far-surface hairline cracks and can form the basis for an enhanced hairline crack detection and characterization for pipeline health monitoring.

  2. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  3. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  4. Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch.

    Science.gov (United States)

    Du, Yi-Chun; Lim, Bee-Yen; Ciou, Wei-Siang; Wu, Ming-Jui

    2016-06-09

    Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients.

  5. Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch

    Directory of Open Access Journals (Sweden)

    Yi-Chun Du

    2016-06-01

    Full Text Available Hemodialysis (HD is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients.

  6. Intelligent Pressure Management to Reduce Leakage in Urban Water Supply Networks, A Case Study of Sarafrazan District, Mashhad

    Directory of Open Access Journals (Sweden)

    Mohammad Soltani Asl

    2009-09-01

    Full Text Available Water losses are inevitable in urban water distribution systems. The two approaches adopted nowadays to combat this problem include management of hydraulic parameters such as pressure and leakage detection in the network. Intellitgent pressure management is a suitable technique for controlling leakage and reducing damages due to high operating pressures in a network. This paper aims to investigate the effects of pressure reduction on leakage. The EPANET 2.10 software is used to simulate the water distribution network in the Sarafrazan District,Mashhad, assuming leakage from network nodes. The results are then used to develop a pressure variation program based on the patterns obtained from the simulation, which is applied to the pressure reducing valve. The results show that pressure management can reduce nightly leakage by up to 35% while maintaining a more uniform pressure distribution. Implementation of the time-dependent pressure pattern by applying programmable pressure reducing valves in a real urban water distribution network is feasible and plays a key role in reducing water losses to leakage.

  7. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    Science.gov (United States)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  8. Numerical and experimental study of the leakage flow in guide vanes with different hydrofoils

    Directory of Open Access Journals (Sweden)

    Sailesh Chitrakar

    2017-07-01

    Full Text Available Clearance gaps between guide vanes and cover plates of Francis turbines tend to increase in size due to simultaneous effect of secondary flow and erosion in sediment affected hydropower plants. The pressure difference between the two sides of the guide vane induces leakage flow through the gap. This flow enters into the suction side with high acceleration, disturbing the primary flow and causing more erosion and losses in downstream turbine components. A cascade rig containing a single guide vane passage has been built to study the effect of the clearance gap using pressure sensors and PIV (Particle Image Velocimetry technique. This study focuses on developing a numerical model of the test rig, validating the results with experiments and investigating the behavior of leakage flow numerically. It was observed from both CFD and experiment that the leakage flow forms a passage vortex, which shifts away from the wall while travelling downstream. The streamlines contributing to the formation of this vortex have been discussed. Furthermore, the reference guide vane with symmetrical hydrofoil has been compared with four cambered profiles, in terms of the guide vane loading and the consequent effect on the leakage flow. A dimensionless term called Leakage Flow Factor (Lff has been introduced to compare the performances of hydrofoils. It is shown that the leakage flow and its effect on increasing losses and erosion can be minimized by changing the pressure distribution over the guide vane.

  9. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  10. Investigation of noise in Lightwave Synthesized Frequency Sweeper seeded LIDAR anemometers from leakage through the Acousto Optic Modulators

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier; Lindelöw, Per Jonas Petter

    2009-01-01

    Train (FSPT) modulated lidars the leakage will give rise to rapidly growing noise in the bins which corresponds to the signal from low radial wind velocities. It is likely that noise canceling techniques similar to those used for RIN removal has to be deployed for measurements of low wind velocities.......Lightwave Synthesized Frequency Sweepers (LSFS) have potential use as lightsources in lidar anemometers. In this paper noise due to leakage in the acousto optic modulators in an LSFS is investigated. Theoretical expressions describing the build-up of noise in the LSFS due to leakage are derived...

  11. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  12. Fabrication of a Textile-Based Wearable Blood Leakage Sensor Using Screen-Offset Printing

    Directory of Open Access Journals (Sweden)

    Ken-ichi Nomura

    2018-01-01

    Full Text Available We fabricate a wearable blood leakage sensor on a cotton textile by combining two newly developed techniques. First, we employ a screen-offset printing technique that avoids blurring, short circuiting between adjacent conductive patterns, and electrode fracturing to form an interdigitated electrode structure for the sensor on a textile. Furthermore, we develop a scheme to distinguish blood from other substances by utilizing the specific dielectric dispersion of blood observed in the sub-megahertz frequency range. The sensor can detect blood volumes as low as 15 μL, which is significantly lower than those of commercially available products (which can detect approximately 1 mL of blood and comparable to a recently reported value of approximately 10 μL. In this study, we merge two technologies to develop a more practical skin-friendly sensor that can be applied for safe, stress-free blood leakage monitoring during hemodialysis.

  13. Effect of membrane and through-wall bending stresses on fatigue crack growth behavior and coolant leakage velocity

    International Nuclear Information System (INIS)

    Yoo, Yeon-Sik

    2003-11-01

    This study clarified the effect of a membrane and a through-wall bending stresses on fatigue crack growth behavior and coolant leakage velocity due to irregularity of crack surface. Each stress component relates to fatigue crack growth behavior directly in general and thus the wild-used K I solutions are anticipated to give good evaluation results on it. Meanwhile, it is necessary to notify that surface irregularity for coolant leakage assessment is made by stress history in nature. Surface irregularity is known to be largely classified into the following two aspects: surface roughness due to continuous crack opening and closure behavior and surface turnover due to cyclic bending stress dominance. Therefore, the deterministic parameters on resistance of coolant leakage by surface irregularity are considered to be not only stress history but crack opening behavior. (author)

  14. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  15. The detection of leakages in open reservoirs by the radioisotope sorption method

    International Nuclear Information System (INIS)

    Owczarczyk, A.; Wierzchnicki, R.; Urbanski, T.; Chmielewski, A.G.; Szpilowski, S.

    1992-01-01

    Location of leakages in large hydro-engineering plants and industrial water reservoirs is of great importance from view-point of both safety and economy of their exploitation. Large variety of water reservoirs encountered in hydro-engineering and industry calls for adaptation of investigation methods to their specific features. In the paper a number of methodological variants of known radiotracer technique developed at the INCT is presented. They are intended to detect and locate leakages in hydro-engineering reservoirs and dams as well as large open industrial tanks. The radioisotopes Au-198 and In-133 m being used for that purpose show excellent sorption characteristic on typical construction materials users to build such objects. (author). 8 refs, 8 figs

  16. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  17. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  18. Application of Electrical Resistivity Tomography Technique for Characterizing Leakage Problem in Abu Baara Earth Dam, Syria

    Directory of Open Access Journals (Sweden)

    Walid Al-Fares

    2014-01-01

    Full Text Available Electrical Resistivity Tomography (ERT survey was carried out at Abu Baara earth dam in northwestern Syria, in order to delineate potential pathways of leakage occurring through the subsurface structure close to the dam body. The survey was performed along two straight measuring profiles of 715 and 430 m length in up- and downstream sides of the dam’s embankment. The analysis of the inverted ERT sections revealed the presence of fractured and karstified limestone rocks which constitute the shallow bedrock of the dam reservoir. Several subsurface structural anomalies were identified within the fractured bedrock, most of which are associated with probable karstic cavities, voids, and discontinuity features developed within the carbonates rocks. Moreover, results also showed the occurrence of a distinguished subsiding structure coinciding with main valley course. Accordingly, it is believed that the bedrock and the other detected features are the main potential causes of water leakage from the dam’s reservoir.

  19. Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery.

    Science.gov (United States)

    Varenika, Vanja; Dickinson, Peter; Bringas, John; LeCouteur, Richard; Higgins, Robert; Park, John; Fiandaca, Massimo; Berger, Mitchel; Sampson, John; Bankiewicz, Krystof

    2008-11-01

    The authors have shown that convection-enhanced delivery (CED) of gadoteridol-loaded liposomes (GDLs) into different regions of normal monkey brain results in predictable, widespread distribution of this tracking agent as detected by real-time MR imaging. They also have found that this tracking technique allows monitoring of the distribution of similar nanosized agents such as therapeutic liposomes and viral vectors. A limitation of this procedure is the unexpected leakage of liposomes out of targeted parenchyma or malignancies into sulci and ventricles. The aim of the present study was to evaluate the efficacy of CED after the onset of these types of leakage. The authors documented this phenomenon in a study of 5 nonhuman primates and 7 canines, comprising 54 CED infusion sessions. Approximately 20% of these infusions resulted in leakage into cerebral ventricles or sulci. All of the infusions and leakage events were monitored with real-time MR imaging. The authors created volume-distributed versus volume-infused graphs for each infusion session. These graphs revealed the rate of distribution of GDL over the course of each infusion and allowed the authors to evaluate the progress of CED before and after leakage. The distribution of therapeutics within the target structure ceased to increase or resulted in significant attenuation after the onset of leakage. An analysis of the cases in this study revealed that leakage undermines the efficacy of CED. These findings reiterate the importance of real-time MR imaging visualization during CED to ensure an accurate, robust distribution of therapeutic agents.

  20. Optimal sensor placement for leakage detection and isolation in water distribution networks

    OpenAIRE

    Rosich Oliva, Albert; Sarrate Estruch, Ramon; Nejjari Akhi-Elarab, Fatiha

    2012-01-01

    In this paper, the problem of leakage detection and isolation in water distribution networks is addressed applying an optimal sensor placement methodology. The chosen technique is based on structural models and thus it is suitable to handle non-linear and large scale systems. A drawback of this technique arises when costs are assigned uniformly. A main contribution of this paper is the proposal of an iterative methodology that focuses on identifying essential sensors which ultimately leads to...

  1. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  2. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  3. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  4. Use of coliform bacteria for the detection of on-line leakage in drinking water

    International Nuclear Information System (INIS)

    Bibi, S.; Karim, H.M.A.; Mashiatullah, A.; Sajjad, I.

    1996-01-01

    In this method, rupture or leakage in under ground water pipes is detected simply by taking the water samples from the main supply lines of the houses and incubating them at 40 deg. C for sixteen hours, colonies (developed with yellow colour) are counted with colony counter. Thirteen samples (in triplicate) collected from different houses in the congested localities during repair work of the major supply line and all of them after test showed heavy rate of pollution. The experiment was repeated for the same locality and sampling sites after completion of repair work. This time the rate of pollution decreases very much showing drastically low growth of microorganisms except for two points. For two further investigation of the nearly leakages at these points, 13 samples (in triplicate) were again collected in serial wise number of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of houses. Two points of the leakage were identified where the growth rate of the microorganisms was abruptly high between two consecutive houses or opposite houses depending upon the supply of water pipe lines showing the leakage of he pipes. This method is useful and causes no health hazard to the population and gives best results where the water supply is on intermittent basis. The technique is specially useful in the remote areas of the country where research facilities are not available and the Pacqualab is a field instrument. So it is handy and rapid method for the detection of leakage in underground water supplies in the remote areas of the country. (author)

  5. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    Directory of Open Access Journals (Sweden)

    Soo-Yeon Kim

    2016-09-01

    Full Text Available There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The performance of the 15 kinds of repair materials that are currently being used in the field of water leakage repair was evaluated by applying the proposed test method. The main aim of such a test method is to determine if there is water leakage by injecting water leakage repair materials into a crack behavior test specimen with an artificial 5-mm crack width, applying a 2.5 mm vertical behavior load at 100 cycles, and applying 0.3 N/mm2 constant water pressure. The test results showed that of the 15 kinds of repair materials, only two effectively sealed the crack and thus stopped the water leakage. The findings of this study confirmed the effectiveness of the proposed artificial-crack-behavior test method and suggest that it can be used as a performance verification method for checking the responsiveness of the repair materials being used in the field of water leakage repair to the repetitive water leakage behaviors that occur in concrete structures. The study findings further suggest that the use of the proposed test method makes it possible to quantify the water leakage repair quality control in the field.

  6. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  7. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  8. Comparison of CT characteristics of extravertebral cement leakages after vertebroplasty performed by different navigation and injection techniques

    International Nuclear Information System (INIS)

    Kaso, G.; Horvath, Z.; Doczi, T.; Szenohradszky, K.; Sandor, J.

    2008-01-01

    This study was intended to assess the results of post-operative CT scans in three groups of patients following percutaneous vertebroplasty (VP) using different navigation and injection methods, in an attempt to explain the radiological characteristics of extravertebral cement leakage with relation to needle placement and focused on the ventral epidural accumulation of bone cement. Furthermore, we have suggested a morphological (and functional) classification of the types of cement leakage. Between July 2001 and February 2005, 123 percutaneous VP procedures were performed during 75 sessions in 65 patients for treatment of painful osteoporotic vertebral body compression fractures. These included: group 1: 28 patients, 33 sessions; 50 right sided unilateral VP under fluoroscopic control with central position of the tip of the needle within the bone marrow. Group 2: 27 patients, 28 sessions; 50 bilateral VP under fluoroscopic control with separate cement injections into both 'hemivertebrae'. Group 3: 14 patients, 14 sessions; 23 bilateral VP navigated by frameless stereotaxy (neuronavigation). Needles were positioned strictly into the lateral thirds of the vertebral bodies. Leakages were classified as epidural, foraminal, intradiscal, venous paravertebral, compact extravertebral on the post-operative CT scans, and their frequency was compared in relation to the navigation method and the position of the tip of the needle. Group 1: extravertebral cement was detected in 23 patients (82 %), and in 35 (70 %) of the 50 vertebrae treated (ventral epidural: 23 vertebrae = 46 %; intradiscal: 12 vertebrae = 24 %; venous paravertebral: 8 vertebrae = 16 %; intraforaminal: 7 vertebrae = 14 %; and compact extravertebral: 3 vertebrae = 6 %). Group 2: extravertebral cement was detected in 20 patients (74 %), and in 38 (76 %) of the 50 vertebrae treated (ventral epidural: 12 vertebrae = 24 %; intradiscal: 12 vertebrae = 24 %; venous paravertebral: 9 vertebrae = 18 %; and foraminal: 1

  9. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  10. Existence of solutions for Hamiltonian field theories by the Hamilton-Jacobi technique

    International Nuclear Information System (INIS)

    Bruno, Danilo

    2011-01-01

    The paper is devoted to prove the existence of a local solution of the Hamilton-Jacobi equation in field theory, whence the general solution of the field equations can be obtained. The solution is adapted to the choice of the submanifold where the initial data of the field equations are assigned. Finally, a technique to obtain the general solution of the field equations, starting from the given initial manifold, is deduced.

  11. Preoperative, intraoperative and postoperative risk factors for anastomotic leakage after laparoscopic low anterior resection with double stapling technique anastomosis.

    Science.gov (United States)

    Kawada, Kenji; Sakai, Yoshiharu

    2016-07-07

    Anastomotic leakage (AL) is one of the most devastating complications after rectal cancer surgery. The double stapling technique has greatly facilitated intestinal reconstruction especially for anastomosis after low anterior resection (LAR). Risk factor analyses for AL after open LAR have been widely reported. However, a few studies have analyzed the risk factors for AL after laparoscopic LAR. Laparoscopic rectal surgery provides an excellent operative field in a narrow pelvic space, and enables total mesorectal excision surgery and preservation of the autonomic nervous system with greater precision. However, rectal transection using a laparoscopic linear stapler is relatively difficult compared with open surgery because of the width and limited performance of the linear stapler. Moreover, laparoscopic LAR exhibits a different postoperative course compared with open LAR, which suggests that the risk factors for AL after laparoscopic LAR may also differ from those after open LAR. In this review, we will discuss the risk factors for AL after laparoscopic LAR.

  12. The comparison of microbial leakage in roots filled with resilon and gutta-percha: An in vitro study.

    Science.gov (United States)

    Shashidhar, C; Shivanna, Vasundhara; Shivamurthy, Gb; Shashidhar, Jyothi

    2011-01-01

    The objective of this study was to compare bacterial leakage using streptococcus mutans through gutta-percha and a thermoplastic synthetic polymer based root canal filling material (Resilon) using two filling techniques. A total of 90 single-rooted extracted human teeth were subjected for the study. Teeth were divided into 6 groups of 10 and 3 control groups of 10 teeth each. All the samples were decoronated and the coronal surfaces of the roots were prepared perpendicular to the long axis of the root with a high-speed handpiece and a multipurpose bur using air water spray. The length of all the roots was prepared approximately 16 mm from the coronal surface to the apex of the root. Roots were filled using lateral and vertical condensation techniques with gutta-percha and AH26 sealer (Group 1 and 2) or with gutta-percha and epiphany sealer (Group 3 and 4). Group 5 and 6 were filled with Resilon and epiphany sealer using the lateral and vertical condensation techniques. A split chamber microbial leakage model was used in which S. mutans placed in the upper chamber could reach the lower chamber only through the filled root canal. Group 7 and 8 (positive control) were filled with Resilon and gutta-percha without sealer and tested with bacteria, whereas Group 7 (negative control) was sealed with wax to test the seal between the chambers. Data were analyzed using Kruskal-Wallis test and Mann-Whitney U test. All positive groups (Group 7 and 8) showed leakage within 1 hour of the start of the study (100%), whereas none of the negative control (Group 9) leaked. The roots obturated with Resilon and epiphany (Group 5 and 6) showed minimal leakage, i.e., each with 6 leakages, which was significantly less than gutta-percha (Group 1-4), in which approximately 80% of specimens with either sealer or techniques leaked. Kruskal-Wallis test showed statistical significance when all groups were compared (P<0.05). Mann-Whitney U test compared the respective groups and found Resilon

  13. Excluded segmental duct bile leakage: the case for bilio-enteric anastomosis.

    Science.gov (United States)

    Patrono, Damiano; Tandoi, Francesco; Romagnoli, Renato; Salizzoni, Mauro

    2014-06-01

    Excluded segmental duct bile leak is the rarest type of post-hepatectomy bile leak and presents unique diagnostic and management features. Classical management strategies invariably entail a significant loss of functioning hepatic parenchyma. The aim of this study is to report a new liver-sparing technique to handle excluded segmental duct bile leakage. Two cases of excluded segmental duct bile leak occurring after major hepatic resection were managed by a Roux-en-Y hepatico-jejunostomy on the excluded segmental duct, avoiding the sacrifice of the liver parenchyma origin of the fistula. In both cases, classical management strategies would have led to the functional loss of roughly 50 % of the liver remnant. Diagnostic and management implications are thoroughly discussed. Both cases had an uneventful postoperative course. The timing of repair was associated with a different outcome: the patient who underwent surgical repair in the acute phase developed no long-term complications, whereas the patient who underwent delayed repair developed a late stenosis requiring percutaneous dilatation. Roux-en-Y hepatico-jejunostomy on the excluded bile duct is a valuable technique in selected cases of excluded segmental duct bile leakage.

  14. Colorectal anastomotic leakage: aspects of prevention, detection and treatment.

    Science.gov (United States)

    Daams, Freek; Luyer, Misha; Lange, Johan F

    2013-04-21

    All colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques should improve results in the future, but standardization and "teachability" should be guaranteed. Risk scoring enables intra-operative decision-making whether to restore continuity or deviate. Early detection can lead to reduction in delay of diagnosis as long as a standard system is used. For treatment options, no firm evidence is available, but future studies could focus on repair and saving of the anastomosis on the one hand or anastomotical breakdown and definitive colostomy on the other hand.

  15. Finding p-Hub Median Locations: An Empirical Study on Problems and Solution Techniques

    Directory of Open Access Journals (Sweden)

    Xiaoqian Sun

    2017-01-01

    Full Text Available Hub location problems have been studied by many researchers for almost 30 years, and, accordingly, various solution methods have been proposed. In this paper, we implement and evaluate several widely used methods for solving five standard hub location problems. To assess the scalability and solution qualities of these methods, three well-known datasets are used as case studies: Turkish Postal System, Australia Post, and Civil Aeronautics Board. Classical problems in small networks can be solved efficiently using CPLEX because of their low complexity. Genetic algorithms perform well for solving three types of single allocation problems, since the problem formulations can be neatly encoded with chromosomes of reasonable size. Lagrangian relaxation is the only technique that solves reliable multiple allocation problems in large networks. We believe that our work helps other researchers to get an overview on the best solution techniques for the problems investigated in our study and also stipulates further interest on cross-comparing solution techniques for more expressive problem formulations.

  16. An Experimental Characterization of Tip Leakage Flows and Corresponding Effects on Multistage Compressor Performance

    Science.gov (United States)

    Berdanier, Reid Adam

    measurements collected at these part-speed and off-design conditions provides a unique data set for calibrating computational models and predictive algorithms. Further investigations with detailed steady total pressure traverses provide additional insight to tip leakage flow effects on stator performance. A series of data on the 100% corrected speedline further characterize the tip leakage flow using time-resolved measurements from a combination of instrumentation techniques. An array of high-frequency-response piezoresistive pressure transducers installed over the rotors allows quantification of tip leakage flow trajectories. These data, along with measurements from a fast-response total pressure probe downstream of the rotors, evaluate the development of tip leakage flows and assess the corresponding effects of upstream stator wakes. Finally, thermal anemometry measurements collected using the single slanted hot-wire technique evaluate three-dimensional velocity components throughout the compressor. These data facilitate calculations of several flow metrics, including a blockage parameter and phase-locked streamwise vorticity.

  17. [Bath Plug Closure Method for Cerebrospinal Fluid Leakage by Endoscopic Endonasal Approach:Cooperative Treatment by Neurosurgeons and Otolaryngologists].

    Science.gov (United States)

    Kawaguchi, Tomohiro; Arakawa, Kazuya; Nomura, Kazuhiro; Ogawa, Yoshikazu; Katori, Yukio; Tominaga, Teiji

    2017-12-01

    Endoscopic endonasal surgery, an innovative surgical technique, is used to approach sinus lesions, lesions of the skull base, and intradural tumors. The cooperation of experienced otolaryngologists and neurosurgeons is important to achieve safe and reliable surgical results. The bath plug closure method is a treatment option for patients with cerebrospinal fluid(CSF)leakage. Although it includes dural and/or intradural procedures, surgery tends to be performed by otolaryngologists because its indications, detailed maneuvers, and pitfalls are not well recognized by neurosurgeons. We reviewed the cases of patients with CSF leakage treated by using the bath plug closure method with an endoscopic endonasal approach at our institution. Three patients were treated using the bath plug closure method. CSF leakage was caused by a meningocele in two cases and trauma in one case. No postoperative intracranial complications or recurrence of CSF leakage were observed. The bath plug closure method is an effective treatment strategy and allows neurosurgeons to gain in-depth knowledge of the treatment options for CSF leakage by using an endoscopic endonasal approach.

  18. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  19. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    -secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol......In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... against continual memory leakage, under the Bilinear Decisional Diffie-Hellman and $2$-linear assumptions. Our schemes have the following properties: 1. Our DPKE and DIBE schemes tolerate leakage at all times, including during refresh. During refresh the tolerated leakage is a (1/2-o (1),1)-fraction...

  20. Heterogeneous neutron-leakage model for PWR pin-by-pin calculation

    International Nuclear Information System (INIS)

    Li, Yunzhao; Zhang, Bin; Wu, Hongchun; Shen, Wei

    2017-01-01

    Highlights: •The derivation of the formula of the leakage model is introduced. This paper evaluates homogeneous and heterogeneous leakage models used in PWR pin-by-pin calculation. •The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. •Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. The computational cost of the newly proposed neutron balance scheme is much less than the power-method scheme and the linear-interpolation scheme. -- Abstract: When assembly calculation is performed with the reflective boundary condition, a leakage model is usually required in the lattice code. The previous studies show that the homogeneous leakage model works effectively for the assembly homogenization. However, it becomes different and unsettled for the pin-cell homogenization. Thus, this paper evaluates homogeneous and heterogeneous leakage models used in pin-by-pin calculation. The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. For practical reactor-core applications, the diffusion coefficients determined by the transport cross-section or by the leakage model are compared with each other to determine which one is more accurate for the Pressurized Water Reactor pin-by-pin calculation. Numerical results have demonstrated that the heterogeneous leakage model together with the diffusion coefficient determined by the heterogeneous leakage model would have the higher accuracy. The new buckling search

  1. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  2. Evaluation of Information Leakage from Cryptographic Hardware via Common-Mode Current

    Science.gov (United States)

    Hayashi, Yu-Ichi; Homma, Naofumi; Mizuki, Takaaki; Sugawara, Takeshi; Kayano, Yoshiki; Aoki, Takafumi; Minegishi, Shigeki; Satoh, Akashi; Sone, Hideaki; Inoue, Hiroshi

    This paper presents a possibility of Electromagnetic (EM) analysis against cryptographic modules outside their security boundaries. The mechanism behind the information leakage is explained from the view point of Electromagnetic Compatibility: electric fluctuation released from cryptographic modules can conduct to peripheral circuits based on ground bounce, resulting in radiation. We demonstrate the consequence of the mechanism through experiments where the ISO/IEC standard block cipher AES (Advanced Encryption Standard) is implemented on an FPGA board and EM radiations from power and communication cables are measured. Correlation Electromagnetic Analysis (CEMA) is conducted in order to evaluate the information leakage. The experimental results show that secret keys are revealed even though there are various disturbing factors such as voltage regulators and AC/DC converters between the target module and the measurement points. We also discuss information-suppression techniques as electrical-level countermeasures against such CEMAs.

  3. The Use of Low-frequency Active Channel Signals in an Information Leakage Detection and Prevention Systems

    Directory of Open Access Journals (Sweden)

    A. V. Mamaev

    2011-06-01

    Full Text Available This article describes a solution for the protection of the temporary lifting of control over the target machine, while using information leakage detection and prevention systems. It is proposed to use a specially designed channel for alert’s signals through the computer’s power supply.

  4. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  5. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  6. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  7. Study of leakages at dam sites in fractured rocks with the aid of the borehole dilution technique

    International Nuclear Information System (INIS)

    Ozbek, E.

    1978-02-01

    The connection between springs which occurred after the impoundment of Keban Lake and the lake was proved by tritium measurements. By additional application of single borehole techniques using radioisotopes as tracers it was possible to localize solution channels in the karstic aquifer as preferential paths for the water movement

  8. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  9. Neutron leakage measurements from a medical linear accelerator

    International Nuclear Information System (INIS)

    Palta, J.R.; Hogstrom, K.R.; Tannanonta, C.

    1984-01-01

    The McCall method has been used to measure neutron leakage from the Mevatron 77, 18- and 15-MV photon beams. Gold foil activation has been used employing a beta counting technique for the 18-MV beam and a gamma counting technique for both the 18- and 15-MV beam. The two counting techniques were used to evaluate their relative merit. The measurements were made at various locations in the patient-treatment plane for different field sizes. The results show that the thermal-neutron dose equivalent contributes only about 1%--2% of the total neutron dose equivalent. At 100 cm, the neutron dose equivalent for the 18-MV beam is approximately six times that of the 15-MV beam, slightly exceeding the 0.1% of the useful beam criteria used by some of the regulatory agencies. In light of the uncertainty in fluence to dose equivalent conversion factors, the increased dose equivalent above 0.1% is insignificant

  10. Risk factors, treatment and impact on outcomes of bile leakage after hemihepatectomy.

    Science.gov (United States)

    Zheng, Si-Ming; Li, Hong; Li, Gen-Cong; Yu, Dan-Song; Ying, Dong-Jian; Zhang, Bin; Lu, Cai-De; Zhou, Xin-Hua

    2017-07-01

    Risk factors for bile leakage after hemihepatectomy are unknown. A prospectively maintained database review identified patients undergoing hemihepatectomy between 1 January 2009 and 30 September 2014. Patients were divided into B/C and non-B/C bile leakage groups. Risk factors for bile leakage were predicted and assessments of their impact on patients were made. Bile leakage occurred in 91 of the 297 patients (30.6%); 64 cases were classified as grade B bile leakage (21.5%) and three cases as grade C bile leakage (1.0%). Multivariate analysis confirmed that elevated preoperative alanine transaminase (ALT), positive bile culture during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery were risk factors for B/C grade bile leakage (P bile leakage (P bile leakage (P bile leakage group were higher than those in the non-B/C bile leakage group (P bile leakage group also required prolonged hospitalization (P 0.05). Patient with elevated preoperative ALT, positive bile cultures during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery are more likely to complicate bile leakage. We should use biliary drainage such as preoperative PTBD, ENBD or intraoperative Kehr's T-tube drainage to reduce and treat bile leakage in patients with high risk of bile leakage. © 2015 Royal Australasian College of Surgeons.

  11. Failure analysis of leakage current in plastic encapsulated packages

    International Nuclear Information System (INIS)

    Hu, S.J.; Cheang, F.T.

    1989-12-01

    Plastic encapsulated packages exhibit high leakage current after a few hundred hours steam pressure pot test. The present study investigates two possible sources of leakage current, the mold compound and the lead frame tape used for taping the lead frame fingers. The results of the study indicate that the leakage current is independent of the frame and is not caused by the mold compound. The data further indicates that it is the ionic contents and acrylic-based adhesive layer of the lead frame tapes which cause the leakage current. To eliminate the leakage current, lead frame tape with low ionic contents and non acrylic-based adhesive should be used. (author). 1 fig., 2 tabs, 3 graphs

  12. Evaluation of organic coatings to reduce air leakage through cracks in the Pickering NGS 'A' reactor building 1

    International Nuclear Information System (INIS)

    Deans, J.J.; Sato, J.A.; Hampton, J.H.D.; Cullen, R.; Paterson, G.; Chan, P.; Rajagopalan, R.

    1994-01-01

    Pressure tests conducted in 1992 on the Pickering NGS 'A' Reactor Building 1 showed that the containment leakage rate of the building was close to the licensing limit. The leakage was found to be pressure dependent and was attributed to cracks in the concrete dome. A number of solutions were studied by a task group, and the application of an organic coating to the exterior surface of the dome was identified as the most viable solution under the constraints of schedule and cost. In addition to reducing the air leakage rate, the coating material must be flexible to bridge existing moving cracks, it must have excellent adhesion to the concrete substrate to sustain the design pressure of 41.4 kPa(g) during pressure tests, and it must be durable for an exterior application and service conditions. Five candidate organic coating materials were selected for laboratory testing. As a result of the testing, a single-component elastomeric polyurethane coating was selected to be used on the dome. This paper discusses the selection process, laboratory tests and results, and the application of the polyurethane coating system to the exterior concrete dome surface. However, the main emphasis of the paper is on the laboratory evaluation of the five candidate materials. (author). 2 refs., 3 tabs., 1 fig

  13. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  14. SU-E-T-774: Use of a Scintillator-Mirror-Camera System for the Measurement of MLC Leakage Radiation with the CyberKnife M6 System

    Energy Technology Data Exchange (ETDEWEB)

    Goggin, L; Kilby, W; Noll, M; Maurer, C [Accuray Inc, Sunnyvale, CA (United States)

    2015-06-15

    Purpose: A technique using a scintillator-mirror-camera system to measure MLC leakage was developed to provide an efficient alternative to film dosimetry while maintaining high spatial resolution. This work describes the technique together with measurement uncertainties. Methods: Leakage measurements were made for the InCise™ MLC using the Logos XRV-2020A device. For each measurement approximately 170 leakage and background images were acquired using optimized camera settings. Average background was subtracted from each leakage frame before filtering the integrated leakage image to replace anomalous pixels. Pixel value to dose conversion was performed using a calibration image. Mean leakage was calculated within an ROI corresponding to the primary beam, and maximum leakage was determined by binning the image into overlapping 1mm x 1mm ROIs. 48 measurements were performed using 3 cameras and multiple MLC-linac combinations in varying beam orientations, with each compared to film dosimetry. Optical and environmental influences were also investigated. Results: Measurement time with the XRV-2020A was 8 minutes vs. 50 minutes using radiochromic film, and results were available immediately. Camera radiation exposure degraded measurement accuracy. With a relatively undamaged camera, mean leakage agreed with film measurement to ≤0.02% in 92% cases, ≤0.03% in 100% (for maximum leakage the values were 88% and 96%) relative to reference open field dose. The estimated camera lifetime over which this agreement is maintained is at least 150 measurements, and can be monitored using reference field exposures. A dependency on camera temperature was identified and a reduction in sensitivity with distance from image center due to optical distortion was characterized. Conclusion: With periodic monitoring of the degree of camera radiation damage, the XRV-2020A system can be used to measure MLC leakage. This represents a significant time saving when compared to the traditional

  15. Gas-path leakage seal for a gas turbine

    Science.gov (United States)

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  16. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  17. An improved technique for oral administration of solutions of test ...

    African Journals Online (AJOL)

    Medicut intravenous cannula as an improvised oral cannula to administer solutions of drugs and test substances to experimental rats. Techniques of handling and manipulating the rat with the goal of having the eosophagus as straight as possible ...

  18. Numerical solution of large nonlinear boundary value problems by quadratic minimization techniques

    International Nuclear Information System (INIS)

    Glowinski, R.; Le Tallec, P.

    1984-01-01

    The objective of this paper is to describe the numerical treatment of large highly nonlinear two or three dimensional boundary value problems by quadratic minimization techniques. In all the different situations where these techniques were applied, the methodology remains the same and is organized as follows: 1) derive a variational formulation of the original boundary value problem, and approximate it by Galerkin methods; 2) transform this variational formulation into a quadratic minimization problem (least squares methods) or into a sequence of quadratic minimization problems (augmented lagrangian decomposition); 3) solve each quadratic minimization problem by a conjugate gradient method with preconditioning, the preconditioning matrix being sparse, positive definite, and fixed once for all in the iterative process. This paper will illustrate the methodology above on two different examples: the description of least squares solution methods and their application to the solution of the unsteady Navier-Stokes equations for incompressible viscous fluids; the description of augmented lagrangian decomposition techniques and their application to the solution of equilibrium problems in finite elasticity

  19. Nanoscale Ferroelectric Switchable Polarization and Leakage Current Behavior in (Ba0.50Sr0.50(Ti0.80Sn0.20O3 Thin Films Prepared Using Chemical Solution Deposition

    Directory of Open Access Journals (Sweden)

    Venkata Sreenivas Puli

    2015-01-01

    Full Text Available Nanoscale switchable ferroelectric (Ba0.50Sr0.50(Ti0.80Sn0.20O3-BSTS polycrystalline thin films with a perovskite structure were prepared on Pt/TiOx/SiO2/Si substrate by chemical solution deposition. X-ray diffraction (XRD spectra indicate that a cubic perovskite crystalline structure and Raman spectra revealed that a tetragonal perovskite crystalline structure is present in the thin films. Sr2+ and Sn4+ cosubstituted film exhibited the lowest leakage current density. Piezoresponse Force Microscopy (PFM technique has been employed to acquire out-of-plane (OPP piezoresponse images and local piezoelectric hysteresis loop in polycrystalline BSTS films. PFM phase and amplitude images reveal nanoscale ferroelectric switching behavior at room temperature. Square patterns with dark and bright contrasts were written by local poling and reversible nature of the piezoresponse behavior was established. Local piezoelectric butterfly amplitude and phase hysteresis loops display ferroelectric nature at nanoscale level. The significance of this paper is to present ferroelectric/piezoelectric nature in present BSTS films at nanoscale level and corroborating ferroelectric behavior by utilizing Raman spectroscopy. Thus, further optimizing physical and electrical properties, BSTS films might be useful for practical applications which include nonvolatile ferroelectric memories, data-storage media, piezoelectric actuators, and electric energy storage capacitors.

  20. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  1. Optimization of path length stretching in Monte Carlo calculations for non-leakage problems

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E. [Delft Univ. of Technology (Netherlands)

    2005-07-01

    Path length stretching (or exponential biasing) is a well known variance reduction technique in Monte Carlo calculations. It can especially be useful in shielding problems where particles have to penetrate a lot of material before being tallied. Several authors sought for optimization of the path length stretching parameter for detection of the leakage of neutrons from a slab. Here the adjoint function behaves as a single exponential function and can well be used to determine the stretching parameter. In this paper optimization is sought for a detector embedded in the system, which changes the adjoint function in the detector drastically. From literature it is known that the combination of path length stretching and angular biasing can result in appreciable variance reduction. However, angular biasing is not generally available in general purpose Monte Carlo codes and therefore we want to restrict ourselves to the application of pure path length stretching and finding optimum parameters for that. Nonetheless, the starting point for our research is the zero-variance scheme. In order to study the solution in detail the simplified monoenergetic two-direction model is adopted, which allows analytical solutions and can still be used in a Monte Carlo simulation. Knowing the zero-variance solution analytically, it is shown how optimum path length stretching parameters can be derived from it. It results in path length shrinking in the detector. Results for the variance in the detector response are shown in comparison with other patterns for the stretching parameter. The effect of anisotropic scattering on the path length stretching parameter is taken into account. (author)

  2. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  3. Radiation-induced off-state leakage current in commercial power MOSFETs

    International Nuclear Information System (INIS)

    Dodd, Paul Emerson; Shaneyfelt, Marty Ray; Draper, Bruce Leroy; Felix, James Andrew; Schwank, James Ralph; Dalton, Scott Matthew

    2005-01-01

    The total dose hardness of several commercial power MOSFET technologies is examined. After exposure to 20 krad(SiO 2 ) most of the n- and p-channel devices examined in this work show substantial (2 to 6 orders of magnitude) increases in off-state leakage current. For the n-channel devices, the increase in radiation-induced leakage current follows standard behavior for moderately thick gate oxides, i.e., the increase in leakage current is dominated by large negative threshold voltage shifts, which cause the transistor to be partially on even when no bias is applied to the gate electrode. N-channel devices biased during irradiation show a significantly larger leakage current increase than grounded devices. The increase in leakage current for the p-channel devices, however, was unexpected. For the p-channel devices, it is shown using electrical characterization and simulation that the radiation-induced leakage current increase is related to an increase in the reverse bias leakage characteristics of the gated diode which is formed by the drain epitaxial layer and the body. This mechanism does not significantly contribute to radiation-induced leakage current in typical p-channel MOS transistors. The p-channel leakage current increase is nearly identical for both biased and grounded irradiations and therefore has serious implications for long duration missions since even devices which are usually powered off could show significant degradation and potentially fail.

  4. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  5. Gold nanoparticles prepared by electro-exploding wire technique in aqueous solutions

    Science.gov (United States)

    Kumar, Lalit; Kapoor, Akanksha; Meghwal, Mayank; Annapoorni, S.

    2016-05-01

    This article presents an effective approach for the synthesis of Au nanoparticles via an environmentally benevolent electro-exploding wire (EEW) technique. In this process, Au nanoparticles evolve through the plasma generated from the parent Au metal. Compared to other typical chemical methods, electro-exploding wire technique is a simple and economical technique which normally operates in water or organic liquids under ambient conditions. Efficient size control was achieved using different aqueous medium like (1mM) NaCl, deionized water and aqueous solution of sodium hydroxide (NaOH, pH 9.5) using identical electro-exploding conditions. The gold nanoparticles exhibited the UV-vis absorption spectrum with a maximum absorption band at 530 nm, similar to that of gold nanoparticles chemically prepared in a solution. The mechanism of size variation of Au nanoparticles is also proposed. The results obtained help to develop methodologies for the control of EEW based nanoparticle growth and the functionalization of nanoparticle surfaces by specific interactions.

  6. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran (Univ. of Gaevle, Gaevle (Sweden)); Meijer, Jan-Erik; Rosqvist, Haakan (NSR AB, Helsingborg (Sweden))

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  7. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  8. Photometric estimation of plutonium in product solutions and acid waste solutions using flow injection analysis technique

    International Nuclear Information System (INIS)

    Dhas, A.J.A.; Dharmapurikar, G.R.; Kumaraguru, K.; Vijayan, K.; Kapoor, S.C.; Ramanujam, A.

    1995-01-01

    Flow injection analysis technique is employed for the measurement of plutonium concentrations in product nitrate solutions by measuring the absorbance of Pu(III) at 565 nm and of Pu(IV) at 470 nm, using a Metrohm 662 photometer, with a pyrex glass tube of 2 nm (ID) inserted in the light path of the detector serving as a flow cell. The photometer detector never comes in contact with radioactive solution. In the case of acid waste solutions Pu is first purified by extraction chromatography with 2-ethyl hexyl hydrogen 2 ethyl hexyl phosphonate (KSM 17)- chromosorb and the Pu in the eluate in complexed with Arsenazo III followed by the measured of absorbance at 665 nm. Absorbance of reference solutions in the desired concentration ranges are measured to calibrate the system. The results obtained agree with the reference values within ±2.0%. (author). 3 refs., 1 tab

  9. Detection Test for Leakage of CO2 into Sodium Loop

    International Nuclear Information System (INIS)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong

    2015-01-01

    This report is about the facility for the detection test for leakage of CO 2 into sodium loop. The facility for the detection test for leakage of CO 2 into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO 2 leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO 2 ) heat exchanger is one of the key components for the supercritical CO 2 Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO 2 heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO 2 exchanger, detection of CO 2 leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO 2 such as sodium carbonate (Na 2 CO 3 ) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na 2 CO 3 in sodium loop has not been developed yet. Therefore, detection of CO 2 and CO from reaction of sodium and CO 2 are proper to detect CO 2 leakage into sodium loop

  10. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  11. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  12. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  13. Zwitterions as alternative draw solutions in forward osmosis for application in wastewater reclamation

    NARCIS (Netherlands)

    Lutchmiah, K.; Lauber, L.; Roest, de K.; Harmsen, D.J.H.; Post, J.W.; Rietveld, L.C.; Lier, van J.B.; Cornelissen, E.R.

    2014-01-01

    The draw solution is the driving force in forward osmosis (FO) processes. The reverse solute leakage of the draw solution is however a major constraint due to cost and energy requirements when reconcentrating the solutes subsequent to the FO process. Several zwitterions as draw solutions (pi

  14. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  15. Internal Leakage Fault Detection and Tolerant Control of Single-Rod Hydraulic Actuators

    Directory of Open Access Journals (Sweden)

    Jianyong Yao

    2014-01-01

    Full Text Available The integration of internal leakage fault detection and tolerant control for single-rod hydraulic actuators is present in this paper. Fault detection is a potential technique to provide efficient condition monitoring and/or preventive maintenance, and fault tolerant control is a critical method to improve the safety and reliability of hydraulic servo systems. Based on quadratic Lyapunov functions, a performance-oriented fault detection method is proposed, which has a simple structure and is prone to implement in practice. The main feature is that, when a prescribed performance index is satisfied (even a slight fault has occurred, there is no fault alarmed; otherwise (i.e., a severe fault has occurred, the fault is detected and then a fault tolerant controller is activated. The proposed tolerant controller, which is based on the parameter adaptive methodology, is also prone to realize, and the learning mechanism is simple since only the internal leakage is considered in parameter adaptation and thus the persistent exciting (PE condition is easily satisfied. After the activation of the fault tolerant controller, the control performance is gradually recovered. Simulation results on a hydraulic servo system with both abrupt and incipient internal leakage fault demonstrate the effectiveness of the proposed fault detection and tolerant control method.

  16. Regulatory analysis for the resolution of generic issue C---8, main steam isolation valve leakage and LCS [leakage control system] failure

    International Nuclear Information System (INIS)

    Graves, C.C.

    1990-06-01

    Generic Issue C-8 deals with staff concerns about public risk because of the incidence of leak test failures reported for main steam isolation valves (MSIVs) at boiling water reactors and the limitations of the leakage control systems (LCSs) for mitigating the consequences of leakage from these valves. If the MSIV leakage is greatly in excess of the allowable value in the technical specifications, the LCS would be unavailable because of design limitations. The issue was initiated in 1983 to assess (1) the causes of MSIV leakage failures, (2) the effectiveness of the LCS and alternative mitigation paths, and (3) the need for additional regulatory action to reduce public risk. This report presents the regulatory analysis for Generic Issue C-8 and concludes that no new regulatory requirements are warranted

  17. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  18. Inhaled corticosteroid metered-dose inhalers: how do variations in technique for solutions versus suspensions affect drug distribution?

    Science.gov (United States)

    Robinson, Christie A; Tsourounis, Candy

    2013-03-01

    To assess the literature that evaluates how variations in metered-dose inhaler (MDI) technique affect lung distribution for inhaled corticosteroids (ICSs) formulated as MDI suspensions and solutions. PubMed (up to November 2012) and Cochrane Library (up to November 2012) were searched using the terms metered-dose inhalers, HFA 134a, Asthma/*drug therapy, and inhaled corticosteroids. In addition, reference citations from publications identified were reviewed. All articles in English from the data sources that assessed MDI technique comparing total lung distribution (TLD) of MDI solutions or suspensions formulated with ICSs were included in the review. Five relevant studies were identified. Five controlled studies compared how variations in MDI technique affect TLD for ICS MDI solutions with suspensions. MDI solutions resulted in greater TLD compared with larger particle MDI suspensions. Delayed or early inspiration upon device actuation of MDI solutions resulted in less TLD than coordinated actuation, but with a 3- to 4-times greater TLD than MDI suspensions inhaled using a standard technique. A sixth study evaluated inspiratory flow rates (IFR) for small, medium, and large particles. Rapid and slow IFRs resulted in similar TLD for small particles, while far fewer particles reached the airways with medium and large particles at rapid, rather than slow, IFRs. Based on the literature evaluated, standard MDI technique should be used for ICS suspensions. ICS MDI solutions can provide a higher average TLD than larger-particle ICS suspensions using standard technique, discoordinated inspiration and medication actuation timing, or rapid and slow IFRs. ICS MDI solutions allow for a more forgiving technique, which makes them uniquely suitable options for patients with asthma who have difficultly with MDI technique.

  19. An objective comparison of leakage between commonly used earplugs.

    Science.gov (United States)

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P leakage when compared with the cotton ball coated with petroleum jelly (P leakage compared with the customized plug (P leakage than the cotton plug (P leakage rate (f(4,45) = 94 [P water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Quantifying the benefit of wellbore leakage potential estimates for prioritizing long-term MVA well sampling at a CO2 storage site.

    Science.gov (United States)

    Azzolina, Nicholas A; Small, Mitchell J; Nakles, David V; Glazewski, Kyle A; Peck, Wesley D; Gorecki, Charles D; Bromhal, Grant S; Dilmore, Robert M

    2015-01-20

    This work uses probabilistic methods to simulate a hypothetical geologic CO2 storage site in a depleted oil and gas field, where the large number of legacy wells would make it cost-prohibitive to sample all wells for all measurements as part of the postinjection site care. Deep well leakage potential scores were assigned to the wells using a random subsample of 100 wells from a detailed study of 826 legacy wells that penetrate the basal Cambrian formation on the U.S. side of the U.S./Canadian border. Analytical solutions and Monte Carlo simulations were used to quantify the statistical power of selecting a leaking well. Power curves were developed as a function of (1) the number of leaking wells within the Area of Review; (2) the sampling design (random or judgmental, choosing first the wells with the highest deep leakage potential scores); (3) the number of wells included in the monitoring sampling plan; and (4) the relationship between a well’s leakage potential score and its relative probability of leakage. Cases where the deep well leakage potential scores are fully or partially informative of the relative leakage probability are compared to a noninformative base case in which leakage is equiprobable across all wells in the Area of Review. The results show that accurate prior knowledge about the probability of well leakage adds measurable value to the ability to detect a leaking well during the monitoring program, and that the loss in detection ability due to imperfect knowledge of the leakage probability can be quantified. This work underscores the importance of a data-driven, risk-based monitoring program that incorporates uncertainty quantification into long-term monitoring sampling plans at geologic CO2 storage sites.

  1. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  2. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  3. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  4. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  5. Recovery of Tin and Nitric Acid from Spent Solder Stripping Solutions

    International Nuclear Information System (INIS)

    Ahn, Jae-Woo; Ryu, Seong-Hyung; Kim, Tae-young

    2015-01-01

    Spent solder-stripping solutions containing tin, copper, iron, and lead in nitric acid solution, are by-products of the manufacture of printed-circuit boards. The recovery of these metals and the nitric acid, for re-use has economic and environmental benefits. In the spent solder-stripping solution, a systematic method to determine a suitable process for recovery of valuable metals and nitric acid was developed. Initially, more than 90% of the tin was successfully recovered as high-purity SnO 2 by thermal precipitation at 80 ℃ for 3 hours. About 94% of the nitric acid was regenerated effectively from the spent solutions by diffusion dialysis, after which there remained copper, iron, and lead in solution. Leakage of tin through the anion-exchange membrane was the lowest (0.026%), whereas Pb-leakage was highest (4.26%). The concentration of the regenerated nitric acid was about 5.1 N.

  6. Modeling PWR systems for monitoring primary-to-secondary leakage using tritium tracer

    International Nuclear Information System (INIS)

    Peiffer, D.G.

    1992-01-01

    This paper discusses several techniques available for monitoring primary to secondary leakage, focusing on the advantages and disadvantages of each. A mathematical model of Millstone 2 describes the behavior of tritium activity in the secondary plant water when a leak exists. Real data from Millstone 2 illustrate the accuracy and reliability of the model and use of the model to measure the mass of water in the secondary system

  7. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  8. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  9. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  10. [Research on the spectral feature and identification of the surface vegetation stressed by stored CO2 underground leakage].

    Science.gov (United States)

    Chen, Yun-Hao; Jiang, Jin-Bao; Steven, Michael D; Gong, A-Du; Li, Yi-Fan

    2012-07-01

    With the global climate warming, reducing greenhouse gas emissions becomes a focused problem for the world. The carbon capture and storage (CCS) techniques could mitigate CO2 into atmosphere, but there is a risk in case that the CO2 leaks from underground. The objective of this paper is to study the chlorophyll contents (SPAD value), relative water contents (RWC) and leaf spectra changing features of beetroot under CO2 leakage stress through field experiment. The result shows that the chlorophyll contents and RWC of beetroot under CO2 leakage stress become lower than the control beetroot', and the leaf reflectance increases in the 550 nm region and decreases in the 680nm region. A new vegetation index (R550/R680) was designed for identifying beetroot under CO2 leakage stress, and the result indicates that the vegetation index R550/R680 could identify the beetroots after CO2 leakage for 7 days. The index has strong sensitivity, stability and identification for monitoring the beetroots under CO2 stress. The result of this paper has very important meaning and application values for selecting spots of CCS project, monitoring and evaluating land-surface ecology under CO2 stress and monitoring the leakage spots by using remote sensing.

  11. Uranium solution mining cost estimating technique: means for rapid comparative analysis of deposits

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Twelve graphs provide a technique for determining relative cost ranges for uranium solution mining projects. The use of the technique can provide a consistent framework for rapid comparative analysis of various properties of mining situations. The technique is also useful to determine the sensitivities of cost figures to incremental changes in mining factors or deposit characteristics

  12. Multiple Solutions of Nonlinear Boundary Value Problems of Fractional Order: A New Analytic Iterative Technique

    Directory of Open Access Journals (Sweden)

    Omar Abu Arqub

    2014-01-01

    Full Text Available The purpose of this paper is to present a new kind of analytical method, the so-called residual power series, to predict and represent the multiplicity of solutions to nonlinear boundary value problems of fractional order. The present method is capable of calculating all branches of solutions simultaneously, even if these multiple solutions are very close and thus rather difficult to distinguish even by numerical techniques. To verify the computational efficiency of the designed proposed technique, two nonlinear models are performed, one of them arises in mixed convection flows and the other one arises in heat transfer, which both admit multiple solutions. The results reveal that the method is very effective, straightforward, and powerful for formulating these multiple solutions.

  13. Helium/solid powder O-ring leakage correlation experiments using a radiotracer

    International Nuclear Information System (INIS)

    Bild, R.W.; Leisher, W.B.; Weissman, S.H.; Seya, M.

    1984-01-01

    UO 2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

  14. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  15. Effect of contrast leakage on the detection of abnormal brain tumor vasculature in high-grade glioma.

    Science.gov (United States)

    LaViolette, Peter S; Daun, Mitchell K; Paulson, Eric S; Schmainda, Kathleen M

    2014-02-01

    Abnormal brain tumor vasculature has recently been highlighted by a dynamic susceptibility contrast (DSC) MRI processing technique. The technique uses independent component analysis (ICA) to separate arterial and venous perfusion. The overlap of the two, i.e. arterio-venous overlap or AVOL, preferentially occurs in brain tumors and predicts response to anti-angiogenic therapy. The effects of contrast agent leakage on the AVOL biomarker have yet to be established. DSC was acquired during two separate contrast boluses in ten patients undergoing clinical imaging for brain tumor diagnosis. Three components were modeled with ICA, which included the arterial and venous components. The percentage of each component as well as a third component were determined within contrast enhancing tumor and compared. AVOL within enhancing tumor was also compared between doses. The percentage of enhancing tumor classified as not arterial or venous and instead into a third component with contrast agent leakage apparent in the time-series was significantly greater for the first contrast dose compared to the second. The amount of AVOL detected within enhancing tumor was also significantly greater with the second dose compared to the first. Contrast leakage results in large signal variance classified as a separate component by the ICA algorithm. The use of a second dose mitigates the effect and allows measurement of AVOL within enhancement.

  16. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    OpenAIRE

    Soo-Yeon Kim; Sang-Keun Oh; Byoungil Kim

    2016-01-01

    There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The per...

  17. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  18. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  19. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  20. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Leakage evaluation in the PCV (Primary Containment Vessel) using chemical and radiochemical data

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nagasawa, Katsumi

    1998-01-01

    Keeping the reliability of nuclear power plant operation, the primary coolant leakage in the PCV is strictly restricted by the Technical Specifications. It is very important to detect an indication of leakage and estimate the source of leakage to provide countermeasures. Usually the indication of leakage will be detected by increase of drain flow in the PCV sump. There are some possibilities of leakage sources in the PCV, such as reactor water, main steam, condensate, feedwater and closed cooling water. The leakage source contain different chemical and radiochemical species. This means that the leakage source can be presumed and detected by using chemical information from the PCV atmosphere and sump water. To detect the leakage indication and the source quickly and exactly, the PCV Leakage Detection Expert System has been developed. This paper describes how to evaluate the leakage indication and source in the PCV by using chemical and radiochemical data. (author)

  2. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario.

    Science.gov (United States)

    Ma, Jing; Zhang, Wangyuan; Zhang, Shaoliang; Zhu, Qianlin; Feng, Qiyan; Chen, Fu

    2017-01-01

    The technology of carbon dioxide (CO 2 ) capture and storage (CCS) has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO 2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO 2 geological storage was designed to investigate the short-term effects of different CO 2 leakage concentration (from 400 g m -2 day -1 to 2,000 g m -2 day -1 ) on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO 2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO 2 concentrations. Increasing CO 2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 ( p soil CO 2 concentration increased. The dominant phylum in the soil samples was Proteobacteria , whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% ( p soil ecosystems.

  3. Botulinum neurotoxin for management of intractable central leakage through a voice prosthesis in surgical voice restoration.

    Science.gov (United States)

    Mullan, G P J; Lee, M T; Clarke, P M

    2006-09-01

    Rehabilitation of voice and speech after total laryngectomy has become established practice in recent years. A voice prosthesis is placed within a surgically produced fistula between the trachea and upper oesophagus and acts as a one way valve, allowing passage of pulmonary air from the trachea into the oesophagus and preventing aspiration of food and fluid from the oesophagus into the trachea. Persistent leakage through or around these prostheses is a recognized complication, the aetiology of which can vary widely, from mechanical issues with the prostheses themselves to anatomical and physiological issues associated with the reconstructed pharynx. We report a new technique of using Dysport in the management of intractable central leakage due to premature and forceful closure of the upper oesophageal sphincter during swallowing. This resulted in the pooling of fluids around the posterior flange of the prosthesis. This, along with the increased pressure from the muscle contraction, led to central leakage, as identified on videofluoroscopy. An injection of Dysport paralysed the upper oesophageal sphincter, preventing pooling of fluids around the prosthesis and the forcing open of the valve. The effect was to eliminate the leakage, and the patient did not require further injections over the following 22 months.

  4. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  5. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  6. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  7. Synchronization of nonidentical chaotic neural networks with leakage delay and mixed time-varying delays

    Directory of Open Access Journals (Sweden)

    Cao Jinde

    2011-01-01

    Full Text Available Abstract In this paper, an integral sliding mode control approach is presented to investigate synchronization of nonidentical chaotic neural networks with discrete and distributed time-varying delays as well as leakage delay. By considering a proper sliding surface and constructing Lyapunov-Krasovskii functional, as well as employing a combination of the free-weighting matrix method, Newton-Leibniz formulation and inequality technique, a sliding mode controller is designed to achieve the asymptotical synchronization of the addressed nonidentical neural networks. Moreover, a sliding mode control law is also synthesized to guarantee the reachability of the specified sliding surface. The provided conditions are expressed in terms of linear matrix inequalities, and are dependent on the discrete and distributed time delays as well as leakage delay. A simulation example is given to verify the theoretical results.

  8. Leakage limits for inflatable seals of sodium cooled fast breeder reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, N.K., E-mail: nksinha@igcar.gov.in; Raj, Baldev

    2014-01-15

    Highlights: • All possible types/modes of gas escape covered. • Limits include simultaneous contributions from bypass and permeation leakage modes. • Leakage of radioactive cover gas with fission products assumed. • Possibility of sodium frost deposition in sealed gap considered. • Cover gas activity decay during fuel handling and relative importance of types/modes of leakage considered for realistic results and simpler seal design. -- Abstract: Estimation and stipulation of allowable leakage for inflatable seals of 500 MWe Prototype Fast Breeder Reactor is depicted. Leakage limits are specified using a conservative approach, which assumes escape of radioactive cover gas with fission products across the seals in bypass and permeation modes and possibility of sodium frost deposition in sealed gaps because of permeation leakage of inflation gas. Procedures to arrive at the allowable leakages of argon cover gas (normal-operation/fuel-handling: 10{sup −3}/10{sup −2} scc/s/m length of seal) and argon inflation gas (10{sup −3} scc/s/m length of seal) is described.

  9. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  10. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  11. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  12. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  13. Studies of axial-leakage simulations for homogeneous and heterogeneous EBR-II core configurations

    International Nuclear Information System (INIS)

    Grimm, K.N.; Meneghetti, D.

    1985-08-01

    When calculations of flux are done in less than three dimensions, leakage-absorption cross sections are normally used to model leakages (flows) in the dimensions for which the flux is not calculated. Since the neutron flux is axially dependent, the leakages, and hence the leakage-absorption cross sections, are also axially dependent. Therefore, to obtain axial flux profiles (or reaction rates) for individual subassemblies, an XY-geometry calculation delineating each subassembly has to be done at several axial heights with space- and energy-dependent leakage-absorption cross sections that are appropriate for each height. This report discusses homogeneous and heterogeneous XY-geometry calculations at various axial locations and using several differing assumptions for the calculation of the leakage-absorption cross section. The positive (outward) leakage-absorption cross sections are modeled as actual leakage absorptions, but the negative (inward) leakage-absorption cross sections are modeled as either negative leakage absorptions (+-B 2 method) or positive downscatter cross sections [the Σ/sub s/(1 → g) method]. 3 refs., 52 figs., 10 tabs

  14. Higher-order Solution of Stochastic Diffusion equation with Nonlinear Losses Using WHEP technique

    KAUST Repository

    El-Beltagy, Mohamed A.

    2014-01-06

    Using Wiener-Hermite expansion with perturbation (WHEP) technique in the solution of the stochastic partial differential equations (SPDEs) has the advantage of converting the problem to a system of deterministic equations that can be solved efficiently using the standard deterministic numerical methods [1]. The Wiener-Hermite expansion is the only known expansion that handles the white/colored noise exactly. The main statistics, such as the mean, covariance, and higher order statistical moments, can be calculated by simple formulae involving only the deterministic Wiener-Hermite coefficients. In this poster, the WHEP technique is used to solve the 2D diffusion equation with nonlinear losses and excited with white noise. The solution will be obtained numerically and will be validated and compared with the analytical solution that can be obtained from any symbolic mathematics package such as Mathematica.

  15. Higher-order Solution of Stochastic Diffusion equation with Nonlinear Losses Using WHEP technique

    KAUST Repository

    El-Beltagy, Mohamed A.; Al-Mulla, Noah

    2014-01-01

    Using Wiener-Hermite expansion with perturbation (WHEP) technique in the solution of the stochastic partial differential equations (SPDEs) has the advantage of converting the problem to a system of deterministic equations that can be solved efficiently using the standard deterministic numerical methods [1]. The Wiener-Hermite expansion is the only known expansion that handles the white/colored noise exactly. The main statistics, such as the mean, covariance, and higher order statistical moments, can be calculated by simple formulae involving only the deterministic Wiener-Hermite coefficients. In this poster, the WHEP technique is used to solve the 2D diffusion equation with nonlinear losses and excited with white noise. The solution will be obtained numerically and will be validated and compared with the analytical solution that can be obtained from any symbolic mathematics package such as Mathematica.

  16. Uncertainty Analysis of In leakage Test for Pressurized Control Room Envelop

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. B. [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In leakage tests for control room envelops(CRE) of newly constructed nuclear power plants are required to prove the control room habitability. Results of the in leakage tests should be analyzed using an uncertainty analysis. Test uncertainty can be an issue if the test results for pressurized CREs show low in leakage. To have a better knowledge of the test uncertainty, a statistical model for the uncertainty analysis is described here and a representative uncertainty analysis of a sample in leakage test is presented. A statistical method for analyzing the uncertainty of the in leakage test is presented here and a representative uncertainty analysis of a sample in leakage test was performed. By using the statistical method we can evaluate the test result with certain level of significance. This method can be more helpful when the difference of the two mean values of the test result is small.

  17. Uncertainty Analysis of In leakage Test for Pressurized Control Room Envelop

    International Nuclear Information System (INIS)

    Lee, J. B.

    2013-01-01

    In leakage tests for control room envelops(CRE) of newly constructed nuclear power plants are required to prove the control room habitability. Results of the in leakage tests should be analyzed using an uncertainty analysis. Test uncertainty can be an issue if the test results for pressurized CREs show low in leakage. To have a better knowledge of the test uncertainty, a statistical model for the uncertainty analysis is described here and a representative uncertainty analysis of a sample in leakage test is presented. A statistical method for analyzing the uncertainty of the in leakage test is presented here and a representative uncertainty analysis of a sample in leakage test was performed. By using the statistical method we can evaluate the test result with certain level of significance. This method can be more helpful when the difference of the two mean values of the test result is small

  18. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  19. Detection of mechanical damage using the magnetic flux leakage technique

    International Nuclear Information System (INIS)

    Clapham, L.; Babbar, V.; Byrne, J.

    2007-01-01

    Since magnetism is strongly stress dependent, Magnetic Flux Leakage (MFL) inspection tools have the potential to locate and characterize mechanical damage in pipelines. However, MFL application to mechanical damage detection faces hurdles which make signal interpretation problematic: 1) the MFL signal is a superposition of geometrical and stress effects; 2) the stress distribution around a mechanically damaged region is very complex, consisting of plastic deformation and residual (elastic) stresses; 3) the effect of stress on magnetic behaviour is not well understood. This paper summarizes recent results of experimental and modeling studies of MFL signals resulting from mechanical damage. In experimental studies, mechanical damage was simulated using a tool and die press to produce dents of varying depths in plate samples. MFL measurements were made before and after selective stress-relieving heat treatments. These annealing treatments enabled the stress and geometry components of the MFL signal to be separated. In general, geometry effects scale with dent depth and tend to dominate in deep dents, while stress contribution to the MFL signals is relatively constant and is more significant for shallow dents. The influence of other parameters such as flux density and topside/bottomside inspection was also quantified. In the finite element analysis work, stress was incorporated by modifying the magnetic permeability in the residual stress regions of the modeled dent. Both stress and geometry contributions to the MFL signal were examined separately. Despite using a number of simplifying assumptions, the modeled results matched the experimental results very closely, and were used to aid in interpretation of the MFL signals. (author)

  20. Leakage current characteristics of the multiple metal alloy nanodot memory

    International Nuclear Information System (INIS)

    Lee, Gae Hun; Lee, Jung Min; Yang, Hyung Jun; Song, Yun Heub; Bea, Ji Chel; Tanaka, Tetsu

    2010-01-01

    The leakage current characteristics of a multiple metal alloy nanodot device for a nonvolatile random access memory using FePt materials are investigated. Several annealing conditions are evaluated and optimized to suppress the leakage current and to better the memory characterisctics. This work confirmed that the annealing condition of 700 .deg. C in a high vacuum ambience (under 1 x 10 -5 Pa) simultaneously provided good cell characteristics from a high dot density of over 1 x 10 13 /cm 2 and a low leakage current. In addition, a smaller nanodot diameter was found to give a lower leakage current for the multiple nanodot memory. Finally, for the proposed annealing condition, the quadruple FePt multiple nanodot memory with a 2-nm dot diameter provided good leakage current characteristics, showing a threshold voltage shift of under 5% at an initial retention stage of 1000 sec.

  1. Quantification of Wellbore Leakage Risk Using Non-destructive Borehole Logging Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Duguid, Andrew; Butsch, Robert; Cary, J.; Celia, Michael; Chugunov, Nikita; Gasda, Sarah; Hovorka, Susan; Ramakrishnan, T. S.; Stamp, Vicki; Thingelstad, Rebecca; Wang, James

    2014-08-29

    Well integrity is important at all potential CCS locations and may play a crucial role establishing leakage risk in areas where there is a high density of existing wells that could be impacted by the storage operations including depleted petroleum fields where EOR or CCS will occur. To address a need for risk quantification methods that can be directly applied to individual wells using borehole logging tools a study was conducted using data from five wells in Wyoming. The objectives of the study were: Objective 1: Develop methods to establish the baseline flow parameters (porosity and permeability or mobility) from individual measurements of the material properties and defects in a well. Objective 2: Develop a correlation between field flow-property data and cement logs that can be used to establish the flow-properties of well materials and well features using cement mapping tools. Objective 3: Establish a method that uses the flow-property model (Objective 2) to analyze the statistical uncertainties associated with individual well leakage that can provide basis for uncertainty in risk calculations. The project objectives were met through the logging of five wells in Carbon and Natrona County Wyoming to collect data that was used to estimate individual and average well flow properties and model the results using ultrasonic data collected during the logging. Three of the five wells provided data on point and average flow properties for well annuli. Data from the other two wells were used to create models of cement permeability and test whether information collected in one well could be used to characterize another well. The results of the in-situ point measurements were confirmed by the lab measurements sidewall cores collected near the same depths Objective 1 was met using the data collected through logging, testing, and sampling. The methods were developed that can establish baseline flow parameters of wells by both point and average test methods. The methods to

  2. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  3. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  4. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  5. Comparing the Titrations of Mixed-Acid Solutions Using Dropwise and Constant-Flow Techniques

    Science.gov (United States)

    Charlesworth, Paul; Seguin, Matthew J.; Chesney, David J.

    2003-11-01

    A mixed-acid solution containing hydrochloric and phosphoric acids was used to determine the error associated with performing a real-time titration. The results were compared against those obtained by performing the titration in a more traditional dropwise addition of titrant near the equivalence points. It was found that the real-time techniques resulted in significantly decreased analysis times while maintaining a low experimental error. The constant-flow techniques were implemented into two different levels of chemistry. It was found that students could successfully utilize the modified experiments. Problems associated with the techniques, major sources of error, and their solutions are discussed. In both cases, the use of the constant-flow setup has increased student recollection of key concepts, such as pKa determination, proper indicator choice, and recognizing the shape of specific titration curves by increasing student interest in the experiment.

  6. Magnetic Flux Leakage and Principal Component Analysis for metal loss approximation in a pipeline

    International Nuclear Information System (INIS)

    Ruiz, M; Mujica, L E; Quintero, M; Florez, J; Quintero, S

    2015-01-01

    Safety and reliability of hydrocarbon transportation pipelines represent a critical aspect for the Oil an Gas industry. Pipeline failures caused by corrosion, external agents, among others, can develop leaks or even rupture, which can negatively impact on population, natural environment, infrastructure and economy. It is imperative to have accurate inspection tools traveling through the pipeline to diagnose the integrity. In this way, over the last few years, different techniques under the concept of structural health monitoring (SHM) have continuously been in development.This work is based on a hybrid methodology that combines the Magnetic Flux Leakage (MFL) and Principal Components Analysis (PCA) approaches. The MFL technique induces a magnetic field in the pipeline's walls. The data are recorded by sensors measuring leakage magnetic field in segments with loss of metal, such as cracking, corrosion, among others. The data provide information of a pipeline with 15 years of operation approximately, which transports gas, has a diameter of 20 inches and a total length of 110 km (with several changes in the topography). On the other hand, PCA is a well-known technique that compresses the information and extracts the most relevant information facilitating the detection of damage in several structures. At this point, the goal of this work is to detect and localize critical loss of metal of a pipeline that are currently working. (paper)

  7. Magnetic Flux Leakage and Principal Component Analysis for metal loss approximation in a pipeline

    Science.gov (United States)

    Ruiz, M.; Mujica, L. E.; Quintero, M.; Florez, J.; Quintero, S.

    2015-07-01

    Safety and reliability of hydrocarbon transportation pipelines represent a critical aspect for the Oil an Gas industry. Pipeline failures caused by corrosion, external agents, among others, can develop leaks or even rupture, which can negatively impact on population, natural environment, infrastructure and economy. It is imperative to have accurate inspection tools traveling through the pipeline to diagnose the integrity. In this way, over the last few years, different techniques under the concept of structural health monitoring (SHM) have continuously been in development. This work is based on a hybrid methodology that combines the Magnetic Flux Leakage (MFL) and Principal Components Analysis (PCA) approaches. The MFL technique induces a magnetic field in the pipeline's walls. The data are recorded by sensors measuring leakage magnetic field in segments with loss of metal, such as cracking, corrosion, among others. The data provide information of a pipeline with 15 years of operation approximately, which transports gas, has a diameter of 20 inches and a total length of 110 km (with several changes in the topography). On the other hand, PCA is a well-known technique that compresses the information and extracts the most relevant information facilitating the detection of damage in several structures. At this point, the goal of this work is to detect and localize critical loss of metal of a pipeline that are currently working.

  8. LMFBR technology. FFTF cover-gas leakage calculation

    International Nuclear Information System (INIS)

    Deboi, H.

    1974-01-01

    The FFTF LMFBR is intended to have a near zero release of radioactive gases during normal reactor operation with 1% failed fuel. This report presents calculations which provide an approximation of these cover gas leakages. Data from ongoing static and dynamic seal leak tests at AI are utilized. Leakage through both elastomeric and metallic seals in all sub-assemblies and penetrations comprising the reactor cover gas containment during reactor operation system are included

  9. Some possible causes and probability of leakages in LMFBR steam generators

    International Nuclear Information System (INIS)

    Bolt, P.R.

    1984-01-01

    Relevant operational experience with steam generators for process and conventional plant and thermal and fast reactors is reviewed. Possible causes of water/steam leakages into sodium/gas are identified and data is given on the conditions necessary for failure, leakage probability and type of leakage path. (author)

  10. Fractal modeling of fluidic leakage through metal sealing surfaces

    Science.gov (United States)

    Zhang, Qiang; Chen, Xiaoqian; Huang, Yiyong; Chen, Yong

    2018-04-01

    This paper investigates the fluidic leak rate through metal sealing surfaces by developing fractal models for the contact process and leakage process. An improved model is established to describe the seal-contact interface of two metal rough surface. The contact model divides the deformed regions by classifying the asperities of different characteristic lengths into the elastic, elastic-plastic and plastic regimes. Using the improved contact model, the leakage channel under the contact surface is mathematically modeled based on the fractal theory. The leakage model obtains the leak rate using the fluid transport theory in porous media, considering that the pores-forming percolation channels can be treated as a combination of filled tortuous capillaries. The effects of fractal structure, surface material and gasket size on the contact process and leakage process are analyzed through numerical simulations for sealed ring gaskets.

  11. Study of true-remanent polarization using remanent hysteresis task and resistive leakage analysis in ferroelectric 0.64Pb(Mg1/3Nb2/3)O3-0.36PbTiO3 ceramics

    Science.gov (United States)

    Joseph, Abhilash J.; Kumar, Binay

    2018-03-01

    The conventionally reported value of remanent polarization (Pr) contains contribution from non-remanent components which are not usable for memory device applications. This report presents techniques which extract the true-remanent (intrinsic) component of polarization after eliminating the non-remanent component in ferroelectric ceramics. For this, "remanent hysteresis task" and "positive-up-negative-down technique" were performed which utilized the switchable properties of polarizations to nullify the contributions from the non-remanent (non-switchable) components. The report also addresses the time-dependent leakage behavior of the ceramics focusing on the presence of resistive leakage (a time-dependent parameter) present in the ceramics. The techniques presented here are especially useful for polycrystalline ceramics where leakage current leads to an erroneous estimation of Pr.

  12. Study on detecting leachate leakage of municipal solid waste landfill site.

    Science.gov (United States)

    Liu, Jiangang; Cao, Xianxian; Ai, Yingbo; Zhou, Dongdong; Han, Qiting

    2015-06-01

    The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7. © The Author(s) 2015.

  13. Obesity prevention: Comparison of techniques and potential solution

    Science.gov (United States)

    Zulkepli, Jafri; Abidin, Norhaslinda Zainal; Zaibidi, Nerda Zura

    2014-12-01

    Over the years, obesity prevention has been a broadly studied subject by both academicians and practitioners. It is one of the most serious public health issue as it can cause numerous chronic health and psychosocial problems. Research is needed to suggest a population-based strategy for obesity prevention. In the academic environment, the importance of obesity prevention has triggered various problem solving approaches. A good obesity prevention model, should comprehend and cater all complex and dynamics issues. Hence, the main purpose of this paper is to discuss the qualitative and quantitative approaches on obesity prevention study and to provide an extensive literature review on various recent modelling techniques for obesity prevention. Based on these literatures, the comparison of both quantitative and qualitative approahes are highlighted and the justification on the used of system dynamics technique to solve the population of obesity is discussed. Lastly, a potential framework solution based on system dynamics modelling is proposed.

  14. Bulk-heterojunction organic solar cells sandwiched by solution processed molybdenum oxide and titania nanosheet layers

    Science.gov (United States)

    Itoh, Eiji; Goto, Yoshinori; Fukuda, Katsutoshi

    2014-02-01

    The contributions of ultrathin titania nanosheet (TN) crystallites were studied in both an inverted bulk-heterojunction (BHJ) cell in an indium-tin oxide (ITO)/titania nanosheet (TN)/poly(3-hexylthiophene) (P3HT):phenyl-C61-butyric acid methylester (PCBM) active layer/MoOx/Ag multilayered photovoltaic device and a conventional BHJ cell in ITO/MoOx/P3HT:PCBM active layer/TN/Al multilayered photovoltaic device. The insertion of only one or two layers of poly(diallyldimethylammonium chloride) (PDDA) and TN multilayered film prepared by the layer-by-layer deposition technique effectively decreased the leakage current and increased the open circuit voltage (VOC), fill factor (FF), and power conversion efficiency (η). The conventional cell sandwiched between a solution-processed, partially crystallized molybdenum oxide hole-extracting buffer layer and a TN electron extracting buffer layer showed comparable cell performance to a device sandwiched between vacuum-deposited molybdenum oxide and TN layers, whereas the inverted cell with solution-processed molybdenum oxide showed a poorer performance probably owing to the increment in the leakage current across the film. The abnormal S-shaped curves observed in the inverted BHJ cell above VOC disappeared with the use of a polyfluorene-based cationic semiconducting polymer as a substitute for an insulating PDDA film, resulting in the improved cell performance.

  15. Leakage potential through mechanical penetrations in a severe accident environment

    International Nuclear Information System (INIS)

    Koenig, L.N.

    1986-01-01

    This paper reviews the findings of an ongoing program, Integrity of Containment Penetrations Under Severe Accident Loads. The program is concerned with the leakage modes as well as the magnitude of leakage through mechanical penetrations in a containment building subject to a severe accident. Seal and gasket tests are used to evaluate the effect of radiation aging, thermal aging, seal geometry, and seal squeeze on seals and gaskets subjected to a hypothesized severe accident. The effects on leakage of the structural response of equipment hatches, personnel airlocks, and drywell heads subjected to severe accident pressures are studied by experiments and analyses. The data gathered during this program will be used to develop methodologies for predicting leakage

  16. [Endoscopic endonasal detection of cerebrospinal fluid leakage with topical fluorescein].

    Science.gov (United States)

    Sato, Taku; Kishida, Yugo; Watanabe, Tadashi; Tani, Akiko; Tada, Yasuhiro; Tamura, Takamitsu; Ichikawa, Masahiro; Sakuma, Jun; Omori, Koichi; Saito, Kiyoshi

    2013-08-01

    We evaluated the effectiveness of intraoperative topical application of fluorescein to detect the leakage point of cerebrospinal fluid(CSF)rhinorrhea. Three patients with CSF rhinorrhea were treated with an endoscopic endonasal technique. Ten percent fluorescein was topically used for intraoperative localization of the leak site. A change of the fluorescein color from brown to green due to dilation of CSF were recognized as evidence of CSF rhinorrhea. We repeated the procedure to detect any small defects. All CSF rhinorrheas were successfully repaired by this endoscopic endonasal approach. Topical application of fluorescein is simple and sensitive for identifying intraoperative CSF rhinorrhea.

  17. Neopterin, kynurenine and tryptophan as new biomarkers for early detection of rectal anastomotic leakage.

    Science.gov (United States)

    Dusek, Tomas; Orhalmi, Julius; Sotona, Otakar; Krcmova, Lenka Kujovska; Javorska, Lenka; Dolejs, Josef; Paral, Jiri

    2018-03-01

    At present, there are no strong predictors, nor a useful scoring system, that clearly identifies patients at risk for anastomotic leakage. This study aimed to investigate a new method that assesses this risk by monitoring levels of neopterin, tryptophan, and kynurenine, in bodily fluids. This prospective study included patients who underwent elective rectal resection for carcinoma. The basic condition for inclusion was rectal anastomosis using the double-stapling technique. Preoperative levels of neopterin, tryptophan, kynurenine, and their ratios, were assessed with blood and urine samples. These levels were then monitored for 6 postoperative days in venous blood, urine, and abdominal drainage fluid. A total of 42 patients were enrolled in the study. Thirty-six patients underwent a laparoscopic resection and 6 patients had an open procedure. No differences were found among neopterin, tryptophan, and kynurenine serum levels. However, the groups were observed to have significant differences in the urinary neopterin/creatinine ratio: the preoperative neopterin/creatinine ratio was 139.5 μmol/mol in the group with leakage, vs 114.8 μmol/mol in the group without complications, p = 0.037. The same results were observed during the postoperative period, p = 0.012. Additionally, the group with complications had a higher mean value of neopterin in drainage fluid, p = 0.048. Our study demonstrated that high preoperative levels of urinary neopterin could be interpreted as a risk for anastomotic leakage. Moreover, pathological levels of neopterin in urine and abdominal drainage fluid could be useful for early identification of anastomotic leakage during the postoperative period prior to its clinical development.

  18. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  19. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  20. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  1. Detection of defect states responsible for leakage current in ultrathin tantalum pentoxide (Ta2O5) films by zero-bias thermally stimulated current spectroscopy

    International Nuclear Information System (INIS)

    Lau, W.S.; Zhong, L.; Lee, A.; See, C.H.; Han, T.; Sandler, N.P.; Chong, T.C.

    1997-01-01

    Defect states responsible for leakage current in ultrathin (physical thickness 2 O 5 ) films were measured with a novel zero-bias thermally stimulated current technique. It was found that defect states A, whose activation energy was estimated to be about 0.2 eV, can be more efficiently suppressed by using N 2 O rapid thermal annealing (RTA) instead of using O 2 RTA for postdeposition annealing. The leakage current was also smaller for samples with N 2 O RTA than those with O 2 RTA for postdeposition annealing. Hence, defect states A are quite likely to be important in causing leakage current. copyright 1997 American Institute of Physics

  2. Detection Test for Leakage of CO{sub 2} into Sodium Loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    This report is about the facility for the detection test for leakage of CO{sub 2} into sodium loop. The facility for the detection test for leakage of CO{sub 2} into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO{sub 2} leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO{sub 2}) heat exchanger is one of the key components for the supercritical CO{sub 2} Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO{sub 2} heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO{sub 2} exchanger, detection of CO{sub 2} leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO{sub 2} such as sodium carbonate (Na{sub 2}CO{sub 3}) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na{sub 2}CO{sub 3} in sodium loop has not been developed yet. Therefore, detection of CO{sub 2} and CO from reaction of sodium and CO{sub 2} are proper to detect CO{sub 2} leakage into sodium loop.

  3. N13 - based reactor coolant pressure boundary leakage system

    International Nuclear Information System (INIS)

    Dissing, E.; Marbaeck, L.; Sandell, S.; Svansson, L.

    1980-05-01

    A system for the monitoring of leakage of coolant from the reactor coolant pressure boundary and auxiliary systems to the reactor containment, based on the detection of the N13 content in the atmosphere, has been tested. N13 is produced from the oxyegen of the reactor water via the recoil photon nuclear process H1 + 016 + He4. The generation of N13 is therefore independent of fuel element leakage and of the corrosion product content in the water. In the US AEC regulatory guide 1.45 has a leakage increase of 4 liter/ min been suggested as the response limit. The experiments carried out in Ringhals indicate, that with the accomplishment of minor improvements in the installation, a 4 liter/min leakage to the containment will give rise to a signal with a random error range of +- 0.25 liter/min, 99.7 % confidence level. (author)

  4. Simulation and experimental research of heat leakage of cryogenic transfer lines

    Science.gov (United States)

    Deng, B. C.; Xie, X. J.; Pan, W.; Jiang, R. X.; Li, J.; Yang, S. Q.; Li, Q.

    2017-12-01

    The heat leakage of cryogenic transfer lines directly influences the performance of large-scale helium refrigerator. In this paper, a thermal model of cryogenic transfer line considering numerical simulation of support coupled with MLI was established. To validate the model, test platform of cryogenic transfer lines with the merits of disassembly outer pipe and changeable easily multi-layer insulation has been built. The experimental results of heat leakage through overall length of cryogenic transfer lines, support and multi-layer insulation were obtained. The heat leakages of multi-layer insulation, a support and the overall leakage are 1.02 W/m, 0.44 W and 1.46 W/m from experimental data, respectively. The difference of heat leakage of MLI between experiment and simulation were less than 5%. The temperature distribution of support and MLI obtained in presented model in good agreement with experimental data. It is expected to reduce the overall heat leakage of cryogenic transfer lines further by optimizing structure of support based on the above thermal model and test platform in this paper.

  5. A direct-conversion WLAN transceiver baseband with DC offset compensation and carrier leakage reduction

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Fang; Yan Jun; Ma Heping; Shi Yin [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Foster, Dai Fa, E-mail: fyuan@sci-inc.com.c [Department of Electrical and Computer Engineering, Auburn University, Auburn, AL 36849-5201 (United States)

    2010-10-15

    A dual-band direct-conversion WLAN transceiver baseband compliant with the IEEE 802.11a/b/g standards is described. Several critical techniques for receiver DC offset compensation and transmitter carrier leakage rejection calibration are presented that enable the direct-conversion architecture to meet all WLAN specifications. The receiver baseband VGA provides 62 dB gain range with steps of 2 dB and a DC offset cancellation circuit is introduced to remove the offset from layout and self-mixing. The calibration loop achieves constant high-pass pole when gain changes; and a fast response time by programming the pole to 1 MHz during preamble and to 30 kHz during receiving data. The transmitter baseband employs an auto-calibration loop with on-chip AD and DA to suppress the carrier leakage, and AD can be powered down after calibration to save power consumption. The chip consumes 17.52 mA for RX baseband VGA and DCOC, and 8.3 mA for TX carrier leakage calibration (5.88 mA after calibration) from 2.85 V supply. Implemented in a 0.35 {mu}m SiGe technology, they occupy 0.68 mm{sup 2} and 0.18 mm{sup 2} die size respectively. (semiconductor integrated circuits)

  6. Pad use and patient reported bother from urinary leakage after radical prostatectomy.

    Science.gov (United States)

    Wallerstedt, Anna; Carlsson, Stefan; Nilsson, Andreas E; Johansson, Eva; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2012-01-01

    To better understand clinically significant definitions of urinary incontinence we investigated the relationship between urinary leakage and patient reported bother from urinary leakage. A consecutive series of 1,411 men who underwent radical prostatectomy at Karolinska University Hospital, Stockholm, Sweden, from 2002 to 2006 were invited to complete a study specific questionnaire with questions on pad status, urinary leakage and bother from urinary leakage. Questionnaires were received from 1,179 men with a followup of greater than 1 year (median 2.2). Results showed that even a small amount of urinary leakage resulted in a high risk of urinary bother. Of 775 survivors 46 (6%) reporting 0 pads indicated moderate or much bother compared to 38 of 123 (31%) who reported using a security pad. When comparing the 2 groups, the risk of bother from urinary leakage was more than 5 times higher in the safety pad vs the 0 pad group (RR 5.2, 95% CI 3.5-7.7). As the number of pads increased, we noted a higher bother risk. Cross-tabulation of pad use and urinary leakage revealed wide variation in pad requirements despite the same answer to urinary leakage questions. If the definition of continence is based on pad use, for example safety pads, a certain number of men who report moderate or much bother from urinary leakage will be defined as continent. Our results also show that for each stated rate of urinary leakage men prove to have a major variation in the pad requirement. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. A new approach for simple radioisotope cisternography examination in cerebrospinal fluid leakage detection.

    Science.gov (United States)

    Hoshino, Hiromitsu; Higuchi, Tetsuya; Achmad, Arifudin; Taketomi-Takahashi, Ayako; Fujimaki, Hiroya; Tsushima, Yoshito

    2016-01-01

    We developed a new quantitative interpretation technique of radioisotope cisternography (RIC) for the diagnosis of spontaneous cerebrospinal fluid hypovolemia (SCH). RIC studies performed for suspected SCH were evaluated. (111)In-DTPA RIC images were taken at 0, 1, 3, 6, and 24-h after radioisotope injection following the current protocol. Regions of interest (ROI) were selected on 3-h images to include brain, spine, bladder or the whole body. The accumulative radioactivity counts were calculated for quantitative analysis. Final diagnoses of SCH were established based on the diagnostic criteria recently proposed by Schievink and colleagues. Thirty-five patients were focused on. Twenty-one (60.0%) patients were diagnosed as having SCH according to the Schievink criteria. On the 3-h images, direct cerebrospinal fluid leakage sign was detected in nine of 21 SCH patients (42.9%), as well as three patients with suspected iatrogenic leakage. Compared to non-SCH patients, SCH patients showed higher bladder accumulation at 3-h images (P = 0.0002), and higher brain clearance between the 6- and 24-h images (P leakage was not observed. 1- and 6-h images did not provide any additional information in any patients. A new simple ROI setting method, in which only the 3-h whole body and 24-h brain images were necessary, was sufficient to diagnose SCH.

  8. On designing of a low leakage patient-centric provider network.

    Science.gov (United States)

    Zheng, Yuchen; Lin, Kun; White, Thomas; Pickreign, Jeremy; Yuen-Reed, Gigi

    2018-03-27

    When a patient in a provider network seeks services outside of their community, the community experiences a leakage. Leakage is undesirable as it typically leads to higher out-of-network cost for patient and increases barrier for care coordination, which is particularly problematic for Accountable Care Organization (ACO) as the in-network providers are financially responsible for quality of care and outcome. We aim to design a data-driven method to identify naturally occurring provider networks driven by diabetic patient choices, and understand the relationship among provider composition, patient composition, and service leakage pattern. By doing so, we learn the features of low service leakage provider networks that can be generalized to different patient population. Data used for this study include de-identified healthcare insurance administrative data acquired from Capital District Physicians' Health Plan (CDPHP) for diabetic patients who resided in four New York state counties (Albany, Rensselaer, Saratoga, and Schenectady) in 2014. We construct a healthcare provider network based on patients' historical medical insurance claims. A community detection algorithm is used to identify naturally occurring communities of collaborating providers. For each detected community, a profile is built using several new key measures to elucidate stakeholders of our findings. Finally, import-export analysis is conducted to benchmark their leakage pattern and identify further leakage reduction opportunity. The design yields six major provider communities with diverse profiles. Some communities are geographically concentrated, while others tend to draw patients with certain diabetic co-morbidities. Providers from the same healthcare institution are likely to be assigned to the same community. While most communities have high within-community utilization and spending, at 85% and 86% respectively, leakage still persists. Hence, we utilize a metric from import-export analysis to

  9. Are You Sure You Want to Contact Us? Quantifying the Leakage of PII via Website Contact Forms

    Directory of Open Access Journals (Sweden)

    Starov Oleksii

    2016-01-01

    Full Text Available The majority of commercial websites provide users the ability to contact them via dedicated contact pages. In these pages, users are typically requested to provide their names, email addresses, and reason for contacting the website. This effectively makes contact pages a gateway from being anonymous or pseudonymous, i.e., identified via stateful and stateless identifiers, to being eponymous. As such, the environment where users provide their personally identifiable information (PII has to be trusted and free from intentional and unintentional information leaks. In this paper, we report on the first large-scale study of PII leakage via contact pages of the 100,000 most popular sites of the web. We develop a reliable methodology for identifying and interacting with contact forms as well as techniques that allow us to discover the leakage of PII towards thirdparties, even when that information is obfuscated. Using these methods, we witness the leakage of PII towards third-parties in a wide range of ways, including the leakage through third-party form submissions, third-party scripts that collect PII information from a first-party page, and unintended leakage through a browser’s Referer header. To recover the lost control of users over their PII, we design and develop Formlock, a browser extension that warns the user when contact forms are using PII-leaking practices, and provides the ability to comprehensively lock-down a form so that a user’s details cannot be, neither accidentally, nor intentionally, leaked to third parties

  10. Process effects on leakage current of Si-PIN neutron detectors with porous microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Baoning; Zhao, Kangkang; Yang, Taotao [Beijing University of Technology, Chaoyang District, Pingleyuan 100, 100124 Beijing (China); Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Ruoshui Road 398, 215123 Suzhou (China); Jiang, Yong; Fan, Xiaoqiang [Institute of Nuclear Physics and Chemistry, CAEP, Mianshan Road 64, 621900 Mianyang (China); Lu, Min [Suzhou Institute of Nano-tech and Nano-bionics, Chinese Academy of Sciences, Ruoshui Road 398, 215123 Suzhou (China); Han, Jun [Beijing University of Technology, Chaoyang District, Pingleyuan 100, 100124 Beijing (China)

    2017-06-15

    Using the technique of Microfabrication, such as deep silicon dry etching, lithography, etc. Si-PIN neutron detectors with porous microstructure have been successfully fabricated. In order to lower the leakage current, the key fabrication processes, including the Al windows opening, deep silicon etching and the porous side wall smoothing, have been optimized. The cross-section morphology and current-voltage characteristics have been measured to evaluate the microfabrication processes. With the optimized conditions presented by the measurements, a neutron detector with a leakage current density of 2.67 μA cm{sup -2} at a bias of -20 V is obtained. A preliminary neutron irradiation test with {sup 252}Cf neutron source has also been carried out. The neutron irradiation test shows that the neutron detection efficiency of the microstructured neutron detectors is almost 3.6 times higher than that of the planar ones. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  12. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  13. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  14. New Method for Leakage Detection by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Attari

    2018-03-01

    Full Text Available Nowadays water loss has been turned into a global concern and on the other hand the demand for water is increasing. This problem has made the demand management and consumption pattern reform necessary. One of the most important methods for managing water consumption is to decrease the water loss. In this study by using neural networks, a new method is presented to specify the location and quantity of leakages in water distribution networks.  In this method, by producing the training data and applying it to neural network, the network is able to determine approximate location and quantity of nodal leakage with receiving the nodal pressure. Production of training data is carried out by applying assumed leakage to specific nodes in the network and calculating the new nodal pressures. The results show that by minimum use of hydraulic data taken from pressures, not only this method can determine the location of nodal leakages, but also it can specify the amount of leakage on each node with reasonable accuracy.

  15. Transcytosis Involvement in Transport System and Endothelial Permeability of Vascular Leakage during Dengue Virus Infection

    Directory of Open Access Journals (Sweden)

    Chanettee Chanthick

    2018-02-01

    Full Text Available The major role of endothelial cells is to maintain homeostasis of vascular permeability and to preserve the integrity of vascular vessels to prevent fluid leakage. Properly functioning endothelial cells promote physiological balance and stability for blood circulation and fluid components. A monolayer of endothelial cells has the ability to regulate paracellular and transcellular pathways for transport proteins, solutes, and fluid. In addition to the paracellular pathway, the transcellular pathway is another route of endothelial permeability that mediates vascular permeability under physiologic conditions. The transcellular pathway was found to be associated with an assortment of disease pathogeneses. The clinical manifestation of severe dengue infection in humans is vascular leakage and hemorrhagic diatheses. This review explores and describes the transcellular pathway, which is an alternate route of vascular permeability during dengue infection that corresponds with the pathologic finding of intact tight junction. This pathway may be the route of albumin transport that causes endothelial dysfunction during dengue virus infection.

  16. Modelling of heterogenous neutron leakages in a nuclear reactor

    International Nuclear Information System (INIS)

    Wohleber, X.

    1997-01-01

    The TIBERE Model is a neutron leakage method based on B 1 heterogeneous transport equation resolution. In this work, we have studied the influence of the reflection mode at the boundary of the assembly. In particular the White boundary condition has been implemented in the APOLLO2 neutron transport code. We have compared the two TIBERE kinds of boundary conditions (specular and white) with the classical B 1 homogeneous leakage method in the modelling of some reactors. We have remarked the better capability of the TIBERE Model to compute voided assemblies. The white boundary condition is also able to compute a completely voided assembly and, besides, wins a factor 10 in CPU time in comparison with the specular boundary condition. These two heterogenous leakage formalisms have been tested on a partially voided experiment and have shown that the TIBERE Model can compute this kind of situation with a greater precision than the classical B 1 homogeneous leakage method, and with a shorter computational time. (author)

  17. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran [Univ. of Gaevle, Gaevle (Sweden); Meijer, Jan-Erik; Rosqvist, Haakan [NSR AB, Helsingborg (Sweden)

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  18. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  19. Leakage based precoding for multi-user MIMO-OFDM systems

    KAUST Repository

    Sadek, Mirette

    2011-08-01

    In downlink multi-user multiple-input multiple-output (MIMO) transmissions, several precoding schemes have been proposed to decrease interference among users. Notable among these precoding schemes is one that uses the signal-to-leakage-plus-noise ratio (SLNR) as an optimization criterion. In this paper, leveraging the efficiency of the SLNR optimization, we generalize this precoding scheme to MIMO orthogonal frequency division multiplexing (OFDM) multi-user systems where the OFDM is used to overcome the inter-symbol- interference (ISI) introduced by multipath channels. We also introduce a channel compensation technique that reconstructs the channel at the transmitter for every time instant given a significantly lower channel feedback rate by the receiver. © 2006 IEEE.

  20. Measurement strategy of the water leakage into a low pressure sodium boundary for a liquid metal reactor

    International Nuclear Information System (INIS)

    Hur, S.; Kim, D.H.; Seong, S.H.; Kim, S.O.

    2004-01-01

    This paper deals with the measurement strategy of a water leakage into sodium boundary for a liquid metal reactor. There are several methods including the chemical sensing method, pressure sensing methods, and non-destructive method including the acoustic monitoring technique to measure the leakage. As for the results of the analysis with respect to the event propagation characteristics, it has been recommended that the acoustic method has a capability to detect small and intermediate leaks within required response time of 10 seconds. A leak of one gram/sec could be currently detected within the required response time of 10 seconds with a high reliability. In the case of less than a one gram/sec leakage, the response time could not meet our requirements due to a complicated signal processing logic. Thus, the system configuration for a fast processing of a leak detection has been recommended. It is expected that this configuration of the leak detection system could reduce the response time due to the distributed and parallel processing scheme. (orig.)

  1. Leakage current analysis of single-phase transformer-less grid-connected PV inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Kerekes, Tamas; Teodorescu, Remus

    2016-01-01

    Transformer-less string PV inverter is getting more and more widely utilized due to its higher efficiency, smaller volume and weight. However, without the galvanic isolation, the leakage current limitation and operation safety became the key issues of transformer-less inverters. This paper...... simplifies the leakage current generation circuit model and presents a leakage current estimation method both in real time and frequency domain. It shows that the leakage current is related to the circuit stray parameters, output filter and common mode voltage. Furthermore, with the proposed analysis method......, the leakage current generation of H-bridge with different modulation methods and HERIC inverter are discussed individually. At last, the presented method has been verified via simulation....

  2. IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE

    International Nuclear Information System (INIS)

    Andrews, J.W.

    2002-01-01

    The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases

  3. Automated detection of leakage in fluorescein angiography images with application to malarial retinopathy.

    Science.gov (United States)

    Zhao, Yitian; MacCormick, Ian J C; Parry, David G; Leach, Sophie; Beare, Nicholas A V; Harding, Simon P; Zheng, Yalin

    2015-06-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage.

  4. ''FIXBOX'' - a new technique for the reliable conditioning of plutonium waste solutions

    International Nuclear Information System (INIS)

    Bruchertseifer, H.; Sommer, E.; Steinemann, M.; Bart, G.

    1994-01-01

    ''FIXBOX'' - A new technique and facility for the conditioning of plutonium waste solutions has been developed and brought into operation in the Hot-laboratory at PSI, for the solidification of the waste from the research programmes. The facility is situated in glove-boxes for handling alpha activity and gamma-shielded for conditioning of fission product-containing waste. This report gives a brief description of the FIXBOX facility, the procedure and the first results of the cementation of plutonium waste solutions. As a result of this solidification, the actinide waste is homogeneous and strongly bound in the cement. The presence of gluconic acid and other complexing agents in the waste solution will not disturb this process. (author) figs., tabs., refs

  5. Application Of The Climafor Baseline To Determine Leakage: TheCase Of Scolel Te.

    Energy Technology Data Exchange (ETDEWEB)

    De Jong, B.H.J.; Bazan, E. Esquivel; Quechulpa Montalvo, S.

    2007-06-01

    The acceptance of forestry-based project activities tomitigate greenhouse gases emissions has been subjected to a number ofmethodological questions to be answered, of which the most challengingare baseline establishment and identification of and measuring leakage.Here we pose hypotheses for and quantify leakage of the Scolel Te projectin Chiapas, Mexico. In this project small-scale farmers are implementingforestry, agroforestry, and forest conservation activities, with carbonsequestration as one of the goals. The main leakage monitoring domain isdefined as the area owned by the participating farmers or communitiesoutside the area where the specific project activities take place. Thenull-hypothesis (no leakage) is that non-project land owned by the farmeror community will experience the same carbon stock changes as predictedby the regional baseline, specifically developed for the project. Firstwe assessed the most likely causes and sources of leakage that may occurin the project. From this analysis, one type of leakage seems to beimportant, i.e., activity shifting. Second we estimated the leakage of asample of participating farmers and communities. Actual land use was thencompared with expected land use derived from the baseline. The Plan Vivoof each participant, complemented with readily available tools toidentify the main sources and drivers of leakage are used to developsimple leakage assessment procedures, as demonstrated in this paper.Negative leakage was estimated to be negligible in this study.Incorporating these procedures already in the project planning stage willreduce the uncertainties related to the actual carbon mitigationpotential of any forestry project.

  6. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  7. Solution of the diffusion equation in the GPT theory by the Laplace transform technique

    International Nuclear Information System (INIS)

    Lemos, R.S.M.; Vilhena, M.T.; Segatto, C.F.; Silva, M.T.

    2003-01-01

    In this work we present a analytical solution to the auxiliary and importance functions attained from the solution of a multigroup diffusion problem in a multilayered slab by the Laplace Transform technique. We also obtain the the transcendental equation for the effective multiplication factor, resulting from the application of the boundary and interface conditions. (author)

  8. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  9. A note on the solution of general Falkner-Skan problem by two novel semi-analytical techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Khidir

    2015-12-01

    Full Text Available The aim of this paper is to give a presentation of two new iterative methods for solving non-linear differential equations, they are successive linearisation method and spectral homotopy perturbation method. We applied these techniques on the non-linear boundary value problems of Falkner-Skan type. The methods used to find a recursive former for higher order equations that are solved using the Chebyshev spectral method to find solutions that are accurate and converge rapidly to the full numerical solution. The methods are illustrated by progressively applying the technique to the Blasius boundary layer equation, the Falkner-Skan equation and finally, the magnetohydrodynamic (MHD Falkner-Skan equation. The solutions are compared to other methods in the literature such as the homotopy analysis method and the spectral-homotopy analysis method with focus on the accuracy and convergence of this new techniques.

  10. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  11. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  12. Integrated Monitoring and Modeling of Carbon Dioxide Leakage Risk Using Remote Sensing, Ground-Based Monitoring, Atmospheric Models and Risk-Indexing Tools

    Science.gov (United States)

    Burton, E. A.; Pickles, W. L.; Gouveia, F. J.; Bogen, K. T.; Rau, G. H.; Friedmann, J.

    2006-12-01

    Correct assessment of the potential for CO2 leakage to the atmosphere or near surface is key to managing the risk associated with CO2 storage. Catastrophic, point-source leaks, diffuse seepage, and low leakage rates all merit assessment. Smaller leaks may be early warnings of catastrophic failures, and may be sufficient to damage natural vegetation or crops. Small leaks also may lead to cumulative build-up of lethal levels of CO2 in enclosed spaces, such as basements, groundwater-well head spaces, and caverns. Working with our ZERT partners, we are integrating a variety of monitoring and modeling approaches to understand how to assess potential health, property and environmental risks across this spectrum of leakage types. Remote sensing offers a rapid technique to monitor large areas for adverse environmental effects. If it can be deployed prior to the onset of storage operations, remote sensing also can document baseline conditions against which future claims of environmental damage can be compared. LLNL has been using hyperspectral imaging to detect plant stress associated with CO2 gas leakage, and has begun investigating use of NASA's new satellite or airborne instrumentation that directly measures gas compositions in the atmosphere. While remote sensing techniques have been criticized as lacking the necessary resolution to address environmental problems, new instruments and data processing techniques are demonstrated to resolve environmental changes at the scale associated with gas-leakage scenarios. During the shallow low-flow- CO2 release field experiments planned by ZERT, for the first time, we will have the opportunity to ground- truth hyperspectral data by simultaneous measurement of changes in hyperspectral readings, soil and root zone microbiology, ambient air, soil and aquifer CO2 concentrations. When monitoring data appear to indicate a CO2 leakage event, risk assessment and mitigation of that event requires a robust and nearly real-time method for

  13. Estimation of Radiofrequency Power Leakage from Microwave Ovens for Dosimetric Assessment at Nonionizing Radiation Exposure Levels

    Directory of Open Access Journals (Sweden)

    Peio Lopez-Iturri

    2015-01-01

    Full Text Available The electromagnetic field leakage levels of nonionizing radiation from a microwave oven have been estimated within a complex indoor scenario. By employing a hybrid simulation technique, based on coupling full wave simulation with an in-house developed deterministic 3D ray launching code, estimations of the observed electric field values can be obtained for the complete indoor scenario. The microwave oven can be modeled as a time- and frequency-dependent radiating source, in which leakage, basically from the microwave oven door, is propagated along the complete indoor scenario interacting with all of the elements present in it. This method can be of aid in order to assess the impact of such devices on expected exposure levels, allowing adequate minimization strategies such as optimal location to be applied.

  14. Chemical colostomy irrigation with glyceryl trinitrate solution.

    Science.gov (United States)

    O'Bichere, A; Bossom, C; Gangoli, S; Green, C; Phillips, R K

    2001-09-01

    Colostomy irrigation may improve patient quality of life, but is time consuming. This study tests the hypothesis that irrigation with glyceryl trinitrate solution, by inducing gastrointestinal smooth muscle relaxation, may accelerate expulsion of stool by passive emptying, thereby reducing irrigation time. Fifteen colostomy irrigators(with more than 3 years' experience) performed washout with tap water compared with water containing 0.025 mg/kg glyceryl trinitrate. Fluid inflow time, total washout time, and hemodynamic changes occurring during glyceryl trinitrate irrigation were documented by an independent observer. Subjects recorded episodes of fecal leakage and overall satisfaction on a visual analog scale. Cramps, headaches, and whether or not a stoma bag was used were expressed as a percentage of number of irrigations. Comparison of fluid inflow time, total washout time, leakage, and satisfaction was by Wilcoxon's signed-rank test and headaches, cramps, and stoma bag use was by McNemar's test. Pulse rate (paired t-test), systolic and diastolic blood pressures (Wilcoxon's test) at 20 and 240 minutes after washout with glyceryl trinitrate solution were compared with baseline. Fifteen patients (9 female), with a mean age of 53 (31-73) years, provided 30 sessions (15 with water and 15 with glyceryl trinitrate). Medians (interquartile ranges) for water vs. glyceryl trinitrate were fluid inflow time 7 (4-10) vs. 4, (3-5; P = 0.001); total washout time 40 (30-55) vs. 21, (15-24; P colostomy irrigation time compared with the generally recommended tap water. Patients suffer fewer leakages and are highly satisfied, but side effects are potential drawbacks. Other colonoplegic agent solutions should now be evaluated.

  15. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  16. Effect of Magnetic Resonance Imaging on Micro leakage of Amalgam Restorations

    International Nuclear Information System (INIS)

    Sayed, A.I.

    2013-01-01

    Objective: To authenticate whether exposure to magnetic resonance imaging (MRI) can cause micro leakage of amalgam restorations or not. Methods: This prospective in-vitro study study was conducted at Faculty of Oral and Dental Medicine, Cairo University. Thirty-six non-carious human teeth (18 premolars and 18 molars), (26 upper and 10 lower) were gathered from the Oral Surgery Department. Standard class V cavities with all margins in the enamel were made on the buccal and lingual aspects after surface debridement .Three groups of teeth were randomly assigned, each containing 12 teeth. Three types of amalgams were used, GS-80, Rupy Cap and Trend alloy. Each type of amalgams was randomly applied to one group. Each group was divided randomly into two equal categories, one was designed to be the control group and the other was scanned by a 1.5 Tesla MRI Scanner for approximately 5 minutes. Micro leakage was assessed in each group. Three amalgam specimens were scanned using 1.5 Tesla Optima MR360 Scanner .The three specimens were sticked to the superior aspect of the medium spine phantom (one specimen per scan) to induce magnetization transfer contrast to easily visualize these in vitro dental ware containing amalgam. The three specimens were scanned using the same Susceptibility Weighted Angiography (SWAN) technique in different orthogonal orientations (Axial, Coronal and Sagittal) to assess the amalgam induced artifacts during MRI scanning. The primary outcome measure was the micro leakage caused by different types of amalgams during MRI scanning; the second outcome measure was the artifacts that may be encountered by different types of amalgams during MRI scanning .

  17. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  18. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  19. Determination of the uranium concentration in soil solutions by the fission track registration technique

    International Nuclear Information System (INIS)

    Fernandes, G.P.

    1980-02-01

    The fission tracks registration technique was used to determine the uranium concentration in soil solutions. The Makrofol KG, a synthetic plastic manufactured by Bayer, was used as a detector and the wet method was applied. From the calibration curves obtained, it was possible to determine uranium concentrations in soil solutions, from 90 to 320 μg U/l, with an error between 9.4% and 4.0%, respectively. The method was applied to a few soil samples from Pocos de Caldas, Minas Gerais in Brazil. The uranium concentrations in the sample and residues were also determined by other methods to compare the results obtained; only one sample showed deviation from the results obtained by the fission tracks method. And this discrepancy was explained in a reasonable way. It was shown that the fission tracks technique can be used with sucess for application in soil solutions. (Author) [pt

  20. Polyaniline (PANI) modified bentonite by plasma technique for U(VI) removal from aqueous solution

    International Nuclear Information System (INIS)

    Liu, Xinghao; Cheng, Cheng; Xiao, Chengjian; Shao, Dadong; Xu, Zimu; Wang, Jiaquan; Hu, Shuheng; Li, Xiaolong; Wang, Weijuan

    2017-01-01

    Highlights: • PANI/bentonie can be synthesized by simple plasma technique. • PANI/bentonie has an excellent adsorption capacity for trace uranium in solution. • U(VI) adsorption on PANI/bentonite is a spontaneous and endothermic process. - Abstract: Polyaniline (PANI) modified bentonite (PANI/bentonie) was synthesized by plasma induced polymerization of aniline on bentonite surface, and applied to uptake of uranium(VI) ions from aqueous solution. The as-synthesized PANI/bentonie was characterized by scanning electron microscopy (SEM), powder X-ray diffraction (XRD), thermal gravimetric analysis (TGA), and X-ray photoelectron spectroscopy (XPS). Batch adsorption technique was utilized to investigate the adsorption of U(VI) on bentonite and PANI/bentonite. The adsorption of U(VI) (10 mg/L) on PANI/bentonite surface is fairly depend on solution pH, ionic strength, and temperature in solution. The modified PANI on PANI/bentonite surface significantly enhances its adsorption capability for U(VI). The presence of humic acid (HA) can sound enhance U(VI) adsorption on PANI/bentonite at pH 6.5. According to the thermodynamic parameters, the adsorption of U(VI) on PANI/bentonite surface is a spontaneous and endothermic process. The results highlight the application of PANI/bentonite composites as candidate material for the uptake of trace U(VI) from aqueous solution.

  1. A Study on the Leakage Characteristic Evaluation of High Temperature and Pressure Pipeline at Nuclear Power Plants Using the Acoustic Emission Technique

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Kim, Jin Hyun; Song, Bong Min; Lee, Joon Hyun; Cho, Youn Ho [Pusan National University, Busan (Korea, Republic of)

    2009-10-15

    An acoustic leak monitoring system(ALMS) using acoustic emission(AE) technique was applied for leakage detection of nuclear power plant's pipeline which is operated in high temperature and pressure condition. Since this system only monitors the existence of leak using the root mean square(RMS) value of raw signal from AE sensor, the difficulty occurs when the characteristics of leak size and shape need to be evaluated. In this study, dual monitoring system using AE sensor and accelerometer was introduced in order to solve this problem. In addition, artificial neural network(ANN) with Levenberg Marquardt(LM) training algorithm was also applied due to rapid training rate and gave the reliable classification performance. The input parameters of this ANN were extracted from varying signal received from experimental conditions such as the fluid pressure inside pipe, the shape and size of the leak area. Additional experiments were also carried out and with different objective which is to study the generation and characteristic of lamb and surface wave according to the pipe thickness

  2. A Study on the Leakage Characteristic Evaluation of High Temperature and Pressure Pipeline at Nuclear Power Plants Using the Acoustic Emission Technique

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Kim, Jin Hyun; Song, Bong Min; Lee, Joon Hyun; Cho, Youn Ho

    2009-01-01

    An acoustic leak monitoring system(ALMS) using acoustic emission(AE) technique was applied for leakage detection of nuclear power plant's pipeline which is operated in high temperature and pressure condition. Since this system only monitors the existence of leak using the root mean square(RMS) value of raw signal from AE sensor, the difficulty occurs when the characteristics of leak size and shape need to be evaluated. In this study, dual monitoring system using AE sensor and accelerometer was introduced in order to solve this problem. In addition, artificial neural network(ANN) with Levenberg Marquardt(LM) training algorithm was also applied due to rapid training rate and gave the reliable classification performance. The input parameters of this ANN were extracted from varying signal received from experimental conditions such as the fluid pressure inside pipe, the shape and size of the leak area. Additional experiments were also carried out and with different objective which is to study the generation and characteristic of lamb and surface wave according to the pipe thickness

  3. Simulating CO₂ leakages from CCS to determine Zn toxicity using the marine microalgae Pleurochrysis roscoffensis.

    Science.gov (United States)

    Bautista-Chamizo, Esther; De Orte, Manoela Romanó; DelValls, Tomás Ángel; Riba, Inmaculada

    2016-02-01

    Due to the current climate change and ocean acidification, a new technology for CO2 mitigation has been proposed, the Carbon dioxide Capture and Storage (CCS). However, there is an ecological risk associated with potential CO2 leakages from the sub-seabed storages sites. To evaluate the effects related to CO2 leakages, laboratory-scales experiments were performed using the marine microalgae Pleurochrysis roscoffensis. Five Zn concentrations were tested at different pHs to study Zn toxicity under acidified conditions. Seawater was collected and submitted to acidification by means of CO2 injection and by HCl addition. Results showed differences between both acidification techniques: while microalgae growth was enhanced by CO2 supply, reaching the optimal growth at pH 6.5 and full inhibition at pH 5.5, HCl acidification growth was inhibited at pH 6.5. Although small concentrations of Zn were positive for P. roscoffensis growth, Zn toxicity increased at lower pHs, and more severely on samples acidified with HCl. The conclusions obtained in this work are useful to address the potential effects on the marine ecosystem related to changes in metal bioavailability during CO2 leakages scenarios. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Satellite assisted aerosol correlation in a sequestered CO2 leakage controlled site

    Science.gov (United States)

    Landulfo, Eduardo; da Silva Lopes, Fábio J.; Nakaema, Walter M.; de Medeiros, José A. G.; Moreira, Andrea

    2014-10-01

    Currently one of the main challenges in CO2 storage research is to grant the development, testing and validation of accurate and efficient Measuring, Monitoring and Verification (MMV) techniques to be deployed at the final storage site, targeting maximum storage efficiency at the minimal leakage risk levels. For such task a mimetic sequestration site has been deployed in Florianopolis, Brazil, in order to verify the performance of monitoring plataforms to detect and quantify leakages of ground injected CO2, namely a Cavity Ring Down System (CRDS) - Los Gatos Research - an Eddy Covariance System (Campbell Scientific and Irgason) and meteorological tower for wind, humidity, precipitation and temperature monitoring onsite. The measurement strategy for detecting CO2 leakages can be very challenging since environmental and phytogenic influence can be very severe and play a role on determining if the values measured are unambiguous or not. One external factor to be considered is the amount of incoming solar radiation which will be the driving force for the whole experimental setup and following this reasoning the amount of aerosols in the atmospheric column can be a determinant factor influencing the experimental results. Thus the investigation of measured fluxes CO2 and its concentration with the aforementioned experimental instruments and their correlation with the aerosol data should be taken into account by means of satellite borne systems dedicated to measure aerosol vertical distribution and its optical properties, in this study we have selected CALIPSO and MODIS instrumentation to help on deriving the aerosol properties and CO2 measurements.

  5. Factors related to ostomy leakage in the community setting.

    Science.gov (United States)

    Ratliff, Catherine R

    2014-01-01

    The purpose of this study was to describe demographic and clinical variables related to ostomy pouch leakage from those discharged from a major medical center during a 2-year period. A convenience sample of 198 persons with an ostomy was obtained using the ICD-9 (International Classification of Diseases, Ninth Revision) codes for colostomy, ileostomy, and ileal conduit for patients who were discharged from the medical center within the time frame of July 2009 to July 2011. One hundred seven participants (55%) returned a completed survey. Respondents included 57 men (53%) and 50 women (47%). The mean age was 60 years with age range from 23 to 91 years. Fecal ostomies made up the majority of the stomas representing 71 patients (66%). A descriptive, cross-sectional research design was used to describe clinical variables related to ostomy pouch leakage for those discharged from a major academic medical center over a 2-year period of time. Participants were mailed an introductory letter from the principal investigator, a self-administered questionnaire, and a prepaid return envelope. Ninety-three patients (87%) reported leakage; however, 48 patients (45%) stated that they did not leak often. A logistic regression was estimated to determine which variables were significant predictors of the dependent variable of leaking status (no/seldom leaking vs more frequent leaking). Two variables were individually significant predictors, sex (P = .021) and 2-piece pouch (P = .015). Women were 4 times more likely to be in the more frequent leaking group than were men. Those who were wearing 2-piece pouches were 78% less likely to be in the more frequent leaking group. Participants with ileostomies or urostomies were more likely to be in the more frequent leaking group and those with peristomal skin irritation were more likely to be in the more frequent leaking group. Findings from this study reveal that women were more likely to experience leakage than men and that wearing a 2-piece

  6. Modeling of leakage currents in high-k dielectrics

    International Nuclear Information System (INIS)

    Jegert, Gunther Christian

    2012-01-01

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO 2 material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO 2 /TiN capacitor structures were suggested and problem areas that may

  7. Modeling of leakage currents in high-k dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Jegert, Gunther Christian

    2012-03-15

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO{sub 2} material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO{sub 2}/TiN capacitor structures were suggested and problem areas

  8. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  9. A study on the measurement of effective energy of leakage X-rays

    International Nuclear Information System (INIS)

    Fijimoto, Nobuhisa; Oogama, Noboru; Nishitani, Motohiro; Yamada, Katsuhiko

    1997-01-01

    It is important to correct for the energy response of the X-ray detector in measuring X-ray leakage from the protective barrier of the examination room. However, measurement of effective energy of leakage X-rays is very difficult in the clinical setting. In this paper, we discuss a method for estimating the effective energy of both primary and scattered X-rays. This method is based on the measurement of leakage X-ray spectra using a semiconductor-fitted X-ray detector and analyzing the relationship between X-ray tube voltage and effective energy. In this study. we found that the effective energy of leakage X-rays was not dependent on the thickness of shielding materials like concrete and lead. With the concrete barrier, it was possible to express the relation-ship between X-ray tube voltage and the effective energy of leakage X-rays with a simple approximate equation. With the lead-lined barrier, the absorption of the K-edge of lead needs to be considered in estimating the effective energy of leakage X-rays at relatively high tube voltages. (author)

  10. CCS Site Optimization by Applying a Multi-objective Evolutionary Algorithm to Semi-Analytical Leakage Models

    Science.gov (United States)

    Cody, B. M.; Gonzalez-Nicolas, A.; Bau, D. A.

    2011-12-01

    Carbon capture and storage (CCS) has been proposed as a method of reducing global carbon dioxide (CO2) emissions. Although CCS has the potential to greatly retard greenhouse gas loading to the atmosphere while cleaner, more sustainable energy solutions are developed, there is a possibility that sequestered CO2 may leak and intrude into and adversely affect groundwater resources. It has been reported [1] that, while CO2 intrusion typically does not directly threaten underground drinking water resources, it may cause secondary effects, such as the mobilization of hazardous inorganic constituents present in aquifer minerals and changes in pH values. These risks must be fully understood and minimized before CCS project implementation. Combined management of project resources and leakage risk is crucial for the implementation of CCS. In this work, we present a method of: (a) minimizing the total CCS cost, the summation of major project costs with the cost associated with CO2 leakage; and (b) maximizing the mass of injected CO2, for a given proposed sequestration site. Optimization decision variables include the number of CO2 injection wells, injection rates, and injection well locations. The capital and operational costs of injection wells are directly related to injection well depth, location, injection flow rate, and injection duration. The cost of leakage is directly related to the mass of CO2 leaked through weak areas, such as abandoned oil wells, in the cap rock layers overlying the injected formation. Additional constraints on fluid overpressure caused by CO2 injection are imposed to maintain predefined effective stress levels that prevent cap rock fracturing. Here, both mass leakage and fluid overpressure are estimated using two semi-analytical models based upon work by [2,3]. A multi-objective evolutionary algorithm coupled with these semi-analytical leakage flow models is used to determine Pareto-optimal trade-off sets giving minimum total cost vs. maximum mass

  11. A new technique in constructing closed-form solutions for nonlinear PDEs appearing in fluid mechanics and gas dynamics

    Directory of Open Access Journals (Sweden)

    Panayotounakos D. E.

    1996-01-01

    Full Text Available We develop a new unique technique in constructing closed-form solutions for several nonlinear partial differential systems appearing in fluid mechanics and gas dynamics. The obtained solutions include fewer arbitrary functions than needed for general solutions, fact that permits us to specify them according to the initial state, or the geometry, of each specific problem under consideration. In order to apply the before mentioned technique we construct closed-form solutions concerning the gas-dynamic equations with constant pressure, the dynamic equations of an ideal gas in isentropic flow, and the two-dimensional incompressible boundary layer flow.

  12. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... completion of the operation the patients were randomized in two groups with and without a transanal stent. RESULTS: A clinically significant leakage was diagnosed in 25 patients (13%). No significant difference was found 17 of 98 patients with a stent and 8 of 96 without (P = 0.09), or in 9 of 44 ileostomy...... patients with a stent and in 3 of 45 without (P = 0.07). Several leaks over a short time led to an interim analysis after inclusion of 194 of 448 planned patients. The analysis showed no significant protective effect of the stent, and more leakages in the stent group, although not statistically significant...

  13. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  14. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  15. A new fabrication technique for back-to-back varactor diodes

    Science.gov (United States)

    Smith, R. Peter; Choudhury, Debabani; Martin, Suzanne; Frerking, Margaret A.; Liu, John K.; Grunthaner, Frank A.

    1992-01-01

    A new varactor diode process has been developed in which much of the processing is done from the back of an extremely thin semiconductor wafer laminated to a low-dielectric substrate. Back-to-back BNN diodes were fabricated with this technique; excellent DC and low-frequency capacitance measurements were obtained. Advantages of the new technique relative to other techniques include greatly reduced frontside wafer damage from exposure to process chemicals, improved capability to integrate devices (e.g. for antenna patterns, transmission lines, or wafer-scale grids), and higher line yield. BNN diodes fabricated with this technique exhibit approximately the expected capacitance-voltage characteristics while showing leakage currents under 10 mA at voltages three times that needed to deplete the varactor. This leakage is many orders of magnitude better than comparable Schottky diodes.

  16. Signal-based Gas Leakage Detection for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Sepehri, Nariman; N. Soltani, Mohsen

    2017-01-01

    This paper describes the development and application of a signal-based fault detection method for identifying gas leakage in hydraulic accumulators used in wind turbines. The method uses Multiresolution Signal Decomposition (MSD) based on wavelets for feature extraction from a~single fluid pressure...... measurement located close to the accumulator. Gas leakage is shown to create increased variations in this pressure signal. The Root Mean Square (RMS) of the detail coefficient Level 9 from the MSD is found as the most sensitive and robust fault indicator of gas leakage. The method is verified...... on an experimental setup allowing for the replication of the conditions for accumulators in wind turbines. Robustness is tested in a multi-fault environment where gas and external fluid leakage occurs simultaneously. In total, 24 experiments are performed, which show that the method is sensitive to gas leakage...

  17. Condensate-polisher resin-leakage quantification and resin-transport studies

    International Nuclear Information System (INIS)

    Stauffer, C.C.; Doss, P.L.

    1983-04-01

    The objectives of this program were to: (1) determine the extent of resin leakage from current generation condensate polisher systems, both deep bed and powdered resin design, during cut-in, steady-state and flow transient operation, (2) analyze moisture separator drains and other secondary system samples for resin fragments and (3) document the level of organics in the secondary system. Resin leakage samples were obtained from nine-power stations that have either recirculating steam generators or once through steam generators. Secondary system samples were obtained from steam generator feedwater, recirculating steam generator blowdown and moisture separator drains. Analysis included ultraviolet light examination, SEM/EDX, resin quantification and infrared analysis. Data obtained from the various plants were compared and factors affecting resin leakage were summarized

  18. On the problem of internal optical loss and current leakage in laser heterostructures based on AlGaInAs/InP solid solutions

    International Nuclear Information System (INIS)

    Veselov, D. A.; Shashkin, I. S.; Bakhvalov, K. V.; Lyutetskiy, A. V.; Pikhtin, N. A.; Rastegaeva, M. G.; Slipchenko, S. O.; Bechvay, E. A.; Strelets, V. A.; Shamakhov, V. V.; Tarasov, I. S.

    2016-01-01

    Semiconductor lasers based on MOCVD-grown AlGaInAs/InP separate-confinement heterostructures are studied. It is shown that raising only the energy-gap width of AlGaInAs-waveguides without the introduction of additional barriers results in more pronounced current leakage into the cladding layers. It is found that the introduction of additional barrier layers at the waveguide–cladding-layer interface blocks current leakage into the cladding layers, but results in an increase in the internal optical loss with increasing pump current. It is experimentally demonstrated that the introduction of blocking layers makes it possible to obtain maximum values of the internal quantum efficiency of stimulated emission (92%) and continuouswave output optical power (3.2 W) in semiconductor lasers in the eye-safe wavelength range (1400–1600 nm).

  19. On the problem of internal optical loss and current leakage in laser heterostructures based on AlGaInAs/InP solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Veselov, D. A., E-mail: dmitriy90@list.ru; Shashkin, I. S.; Bakhvalov, K. V.; Lyutetskiy, A. V.; Pikhtin, N. A.; Rastegaeva, M. G.; Slipchenko, S. O.; Bechvay, E. A.; Strelets, V. A.; Shamakhov, V. V.; Tarasov, I. S. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation)

    2016-09-15

    Semiconductor lasers based on MOCVD-grown AlGaInAs/InP separate-confinement heterostructures are studied. It is shown that raising only the energy-gap width of AlGaInAs-waveguides without the introduction of additional barriers results in more pronounced current leakage into the cladding layers. It is found that the introduction of additional barrier layers at the waveguide–cladding-layer interface blocks current leakage into the cladding layers, but results in an increase in the internal optical loss with increasing pump current. It is experimentally demonstrated that the introduction of blocking layers makes it possible to obtain maximum values of the internal quantum efficiency of stimulated emission (92%) and continuouswave output optical power (3.2 W) in semiconductor lasers in the eye-safe wavelength range (1400–1600 nm).

  20. HPAT: A nondestructive analysis technique for plutonium and uranium solutions

    International Nuclear Information System (INIS)

    Aparo, M.; Mattia, B.; Zeppa, P.; Pagliai, V.; Frazzoli, F.V.

    1989-03-01

    Two experimental approaches for the nondestructive characterization of mixed solutions of plutonium and uranium, developed at BNEA - C.R.E. Casaccia, with the goal of measuring low plutonium concentration (<50 g/l) even in presence of high uranium content, are described in the following. Both methods are referred to as HPAT (Hybrid Passive-Active Technique) since they rely on the measurement of plutonium spontaneous emission in the LX-rays energy region as well as the transmission of KX photons from the fluorescence induced by a radioisotopic source on a suitable target. Experimental campaigns for the characterization of both techniques have been carried out at EUREX Plant Laboratories (C.R.E. Saluggia) and at Plutonium Plant Laboratories (C.R.E. Casaccia). Experimental results and theoretical value of the errors are reported. (author)

  1. Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures: Analysis of Risk Factors.

    Science.gov (United States)

    Xie, Weixing; Jin, Daxiang; Ma, Hui; Ding, Jinyong; Xu, Jixi; Zhang, Shuncong; Liang, De

    2016-05-01

    The risk factors for cement leakage were retrospectively reviewed in 192 patients who underwent percutaneous vertebral augmentation (PVA). To discuss the factors related to the cement leakage in PVA procedure for the treatment of osteoporotic vertebral compression fractures. PVA is widely applied for the treatment of osteoporotic vertebral fractures. Cement leakage is a major complication of this procedure. The risk factors for cement leakage were controversial. A retrospective review of 192 patients who underwent PVA was conducted. The following data were recorded: age, sex, bone density, number of fractured vertebrae before surgery, number of treated vertebrae, severity of the treated vertebrae, operative approach, volume of injected bone cement, preoperative vertebral compression ratio, preoperative local kyphosis angle, intraosseous clefts, preoperative vertebral cortical bone defect, and ratio and type of cement leakage. To study the correlation between each factor and cement leakage ratio, bivariate regression analysis was employed to perform univariate analysis, whereas multivariate linear regression analysis was employed to perform multivariate analysis. The study included 192 patients (282 treated vertebrae), and cement leakage occurred in 100 vertebrae (35.46%). The vertebrae with preoperative cortical bone defects generally exhibited higher cement leakage ratio, and the leakage is typically type C. Vertebrae with intact cortical bones before the procedure tend to experience type S leakage. Univariate analysis showed that patient age, bone density, number of fractured vertebrae before surgery, and vertebral cortical bone were associated with cement leakage ratio (Pcement leakage are bone density and vertebral cortical bone defect, with standardized partial regression coefficients of -0.085 and 0.144, respectively. High bone density and vertebral cortical bone defect are independent risk factors associated with bone cement leakage.

  2. Polyaniline (PANI) modified bentonite by plasma technique for U(VI) removal from aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinghao [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Intelligent Manufacturing Technology Research Institute, Hefei University of Technology, Hefei 230088 (China); Cheng, Cheng [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Xiao, Chengjian, E-mail: xiaocj@caep.cn [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China); Shao, Dadong, E-mail: shaodadong@126.com [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Xu, Zimu, E-mail: xzm@mail.ustc.edu.cn [Intelligent Manufacturing Technology Research Institute, Hefei University of Technology, Hefei 230088 (China); Wang, Jiaquan; Hu, Shuheng [Intelligent Manufacturing Technology Research Institute, Hefei University of Technology, Hefei 230088 (China); Li, Xiaolong; Wang, Weijuan [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900 (China)

    2017-07-31

    Highlights: • PANI/bentonie can be synthesized by simple plasma technique. • PANI/bentonie has an excellent adsorption capacity for trace uranium in solution. • U(VI) adsorption on PANI/bentonite is a spontaneous and endothermic process. - Abstract: Polyaniline (PANI) modified bentonite (PANI/bentonie) was synthesized by plasma induced polymerization of aniline on bentonite surface, and applied to uptake of uranium(VI) ions from aqueous solution. The as-synthesized PANI/bentonie was characterized by scanning electron microscopy (SEM), powder X-ray diffraction (XRD), thermal gravimetric analysis (TGA), and X-ray photoelectron spectroscopy (XPS). Batch adsorption technique was utilized to investigate the adsorption of U(VI) on bentonite and PANI/bentonite. The adsorption of U(VI) (10 mg/L) on PANI/bentonite surface is fairly depend on solution pH, ionic strength, and temperature in solution. The modified PANI on PANI/bentonite surface significantly enhances its adsorption capability for U(VI). The presence of humic acid (HA) can sound enhance U(VI) adsorption on PANI/bentonite at pH < 6.5 because of the strong complexation, and inhibits U(VI) adsorption at pH > 6.5. According to the thermodynamic parameters, the adsorption of U(VI) on PANI/bentonite surface is a spontaneous and endothermic process. The results highlight the application of PANI/bentonite composites as candidate material for the uptake of trace U(VI) from aqueous solution.

  3. Influence of process parameters on threshold voltage and leakage current in 18nm NMOS device

    Science.gov (United States)

    Atan, Norani Binti; Ahmad, Ibrahim Bin; Majlis, Burhanuddin Bin Yeop; Fauzi, Izzati Binti Ahmad

    2015-04-01

    The process parameters are very crucial factor in the development of transistors. There are many process parameters that influenced in the development of the transistors. In this research, we investigate the effects of the process parameters variation on response characteristics such as threshold voltage (VTH) and sub-threshold leakage current (IOFF) in 18nm NMOS device. The technique to identify semiconductor process parameters whose variability would impact most on the device characteristic is realized through the process by using Taguchi robust design method. This paper presents the process parameters that influenced in threshold voltage (VTH) and sub-threshold leakage current (IOFF) which includes the Halo Implantation, Compensation Implantation, Adjustment Threshold voltage Implantation and Source/Drain Implantation. The design, fabrication and characterization of 18nm HfO2/TiSi2 NMOS device is simulated and performed via a tool called Virtual Wafer Fabrication (VWF) Silvaco TCAD Tool known as ATHENA and ATLAS simulators. These two simulators were combined with Taguchi L9 Orthogonal method to aid in the design and the optimization of the process parameters to achieve the optimum average of threshold voltage (VTH) and sub-threshold leakage current, (IOFF) in 18nm device. Results from this research were obtained; where Halo Implantation dose was identified as one of the process parameter that has the strongest effect on the response characteristics. Whereby the Compensation Implantation dose was identified as an adjustment factor to get the nominal values of threshold voltage VTH, and sub-threshold leakage current, IOFF for 18nm NMOS devices equal to 0.302849 volts and 1.9123×10-16 A/μm respectively. The design values are referred to ITRS 2011 prediction.

  4. Impact of leakage delay on bifurcation in high-order fractional BAM neural networks.

    Science.gov (United States)

    Huang, Chengdai; Cao, Jinde

    2018-02-01

    The effects of leakage delay on the dynamics of neural networks with integer-order have lately been received considerable attention. It has been confirmed that fractional neural networks more appropriately uncover the dynamical properties of neural networks, but the results of fractional neural networks with leakage delay are relatively few. This paper primarily concentrates on the issue of bifurcation for high-order fractional bidirectional associative memory(BAM) neural networks involving leakage delay. The first attempt is made to tackle the stability and bifurcation of high-order fractional BAM neural networks with time delay in leakage terms in this paper. The conditions for the appearance of bifurcation for the proposed systems with leakage delay are firstly established by adopting time delay as a bifurcation parameter. Then, the bifurcation criteria of such system without leakage delay are successfully acquired. Comparative analysis wondrously detects that the stability performance of the proposed high-order fractional neural networks is critically weakened by leakage delay, they cannot be overlooked. Numerical examples are ultimately exhibited to attest the efficiency of the theoretical results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  6. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  7. The Effect of Internal Leakages on Thermal Performance in NPPs

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Kim, Doo Won; Jang, Seok Bo

    2007-01-01

    Since the Balance Of Plant (BOP, limited to a turbine cycle in this study) does not contain radioactive material, regulatory authorities did not need to have concerns on it. As the interests on safety and performance is getting more serious and extensive, controlling the level of safety and performance of a BOP have just begun or is about to begin. The performance standards or ageing management programs of the major equipment in a BOP is being developed. The regulatory requirements for tests and/or maintenance are being actively built up. There is also a probabilistic approach quantifying performance of a BOP. The study on quantifying the rate of unanticipated shutdowns caused by careless maintenance and/or tests conducted in a BOP is going on. In this study, the modeling of the entire BOP and the methodologies of thermal performance analysis should be one of the must-have items as well. This study was achieved to ensure fundamental skills related to 1) the detailed steady-state modeling of a BOP and 2) thermal performance analysis under various conditions. Particularly, the paper will focus on the effect of internal leakages inside the valves and FeedWater Heaters (FWHs). The internal leakage is regarded as the flow movement through the isolated path but remaining inside the system boundary of a BOP. For instance, the leakage from one side of a valve seat to the other side, or the leakage through the cracked tubes or tube-sheets in a heat exchanger correspond to internal leakages. We made a BOP model of OPR1000 and investigated thermal performance under the internal leakage in Turbine Bypass Condenser Dump Valves (TBCDV) and FWHs

  8. Real-Time Scheduling for Preventing Information Leakage with Preemption Overheads

    Directory of Open Access Journals (Sweden)

    BAEK, H.

    2017-05-01

    Full Text Available Real-time systems (RTS are characterized by tasks executing in a timely manner to meet its deadlines as a real-time constraint. Most studies of RTS have focused on these criteria as primary design points. However, recent increases in security threats to various real-time systems have shown that enhanced security support must be included as an important design point, retro-fitting such support to existing systems as necessary. In this paper, we propose a new pre-flush technique referred to as flush task reservation for FP scheduling (FTR-FP to conditionally sanitize the state of resources shared by real-time tasks by invoking a flush task (FT in order to mitigate information leakage/corruption of real-time systems. FTR-FP extends existing works exploiting FTs to be applicable more general scheduling algorithms and security model. We also propose modifications to existing real-time scheduling algorithms to implement a pre-flush technique as a security constraint, and analysis technique to verify schedulability of the real-time scheduling. For better analytic capability, our analysis technique provides a count of the precise number of preemptions that a task experiences offline. Our evaluation results demonstrate that our proposed schedulability analysis improves the performance of existing scheduling algorithms in terms of schedulability and preemption cost.

  9. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  10. ERROR REDUCTION IN DUCT LEAKAGE TESTING THROUGH DATA CROSS-CHECKS

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS, J.W.

    1998-12-31

    One way to reduce uncertainty in scientific measurement is to devise a protocol in which more quantities are measured than are absolutely required, so that the result is over constrained. This report develops a method for so combining data from two different tests for air leakage in residential duct systems. An algorithm, which depends on the uncertainty estimates for the measured quantities, optimizes the use of the excess data. In many cases it can significantly reduce the error bar on at least one of the two measured duct leakage rates (supply or return), and it provides a rational method of reconciling any conflicting results from the two leakage tests.

  11. A retrospective analysis of endoscopic treatment outcomes in patients with postoperative bile leakage.

    Science.gov (United States)

    Sayar, Suleyman; Olmez, Sehmus; Avcioglu, Ufuk; Tenlik, Ilyas; Saritas, Bunyamin; Ozdil, Kamil; Altiparmak, Emin; Ozaslan, Ersan

    2016-01-01

    Bile leakage, while rare, can be a complication seen after cholecystectomy. It may also occur after hepatic or biliary surgical procedures. Etiology may be underlying pathology or surgical complication. Endoscopic retrograde cholangiopancreatography (ERCP) can play major role in diagnosis and treatment of bile leakage. Present study was a retrospective analysis of outcomes of ERCP procedure in patients with bile leakage. Patients who underwent ERCP for bile leakage after surgery between 2008 and 2012 were included in the study. Etiology, clinical and radiological characteristics, and endoscopic treatment outcomes were recorded and analyzed. Total of 31 patients (10 male, 21 female) were included in the study. ERCP was performed for bile leakage after cholecystectomy in 20 patients, after hydatid cyst operation in 10 patients, and after hepatic resection in 1 patient. Clinical signs and symptoms of bile leakage included abdominal pain, bile drainage from percutaneous drain, peritonitis, jaundice, and bilioma. Twelve (60%) patients were treated with endoscopic sphincterotomy (ES) and nasobiliary drainage (NBD) catheter, 7 patients (35%) were treated with ES and biliary stent (BS), and 1 patient (5%) was treated with ES alone. Treatment efficiency was 100% in bile leakage cases after cholecystectomy. Ten (32%) cases of hydatid cyst surgery had subsequent cystobiliary fistula. Of these patients, 7 were treated with ES and NBD, 2 were treated with ES and BS, and 1 patient (8%) with ES alone. Treatment was successful in 90% of these cases. ERCP is an effective method to diagnose and treat bile leakage. Endoscopic treatment of postoperative bile leakage should be individualized based on etiological and other factors, such as accompanying fistula.

  12. BinCat: a Catalog of Nearby Binary Stars with Tools for Calculating Light-Leakage for Direct Imaging Missions

    Science.gov (United States)

    Holte, Elias Peter; Sirbu, Dan; Belikov, Ruslan

    2018-01-01

    Binary stars have been largely left out of direct imaging surveys for exoplanets, specifically for earth-sized planets in their star's habitable zone. Utilizing new direct imaging techniques brings us closer to being able to detect earth-like exoplanets around binary stars. In preparation for the upcoming WFIRST mission and other direct imaging-capable missions (HabEx, LUVIOR) it is important to understand the expected science yield resulting from the implementation of these imaging techniques. BinCat is a catalog of binary systems within 30 parsecs to be used as a target list for future direct imaging missions. There is a non-static component along with BinCat that allows researchers to predict the expected light-leakage between a binary component and its off-axis companion (a value critical to the aforementioned techniques) at any epoch. This is accomplished by using orbital elements from the Sixth Orbital Catalog to model the orbits of the binaries. The software was validated against the historical data used to generate the orbital parameters. When orbital information is unknown or the binaries are purely optical the proper motion of the pair taken from the Washington Double Star catalog is integrated in time to estimate expected light-leakage.

  13. Leakage monitoring and maintenance for main heat-exchanger of project 871

    International Nuclear Information System (INIS)

    Li Yanshui; Cao Zhibin

    1995-01-01

    Main heat-exchanger is one of the most important equipment. To prevent the occurrence of leakage accident, desalting and water treatment for secondary cooling water is conducted chemical except controlling the water quality of coolant. There is a small loop for leakage monitoring to find out the leakage immediately. In order to ensure the safety of operation, the treatment of eliminating water dirt and inspection for outside and inside must be done periodically, and the relevant means must be adopted if any abnormal phenomenon is found

  14. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study.

    Science.gov (United States)

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann-Whitney U-test, Kruskal-Wallis H-test and the results were statistically significant P provisional crowns cemented with three different luting cements along the axial walls of

  15. Using the Bongwana natural CO2 release to understand leakage processes and develop monitoring

    Science.gov (United States)

    Jones, David; Johnson, Gareth; Hicks, Nigel; Bond, Clare; Gilfillan, Stuart; Kremer, Yannick; Lister, Bob; Nkwane, Mzikayise; Maupa, Thulani; Munyangane, Portia; Robey, Kate; Saunders, Ian; Shipton, Zoe; Pearce, Jonathan; Haszeldine, Stuart

    2016-04-01

    Natural CO2 leakage along the Bongwana Fault in South Africa is being studied to help understand processes of CO2 leakage and develop monitoring protocols. The Bongwana Fault crops out over approximately 80 km in KwaZulu-Natal province, South Africa. In outcrop the fault is expressed as a broad fracture corridor in Dwyka Tillite, with fractures oriented approximately N-S. Natural emissions of CO2 occur at various points along the fault, manifest as travertine cones and terraces, bubbling in the rivers and as gas fluxes through soil. Exposed rock outcrop shows evidence for Fe-staining around fractures and is locally extensively kaolinitised. The gas has also been released through a shallow water well, and was exploited commercially in the past. Preliminary studies have been carried out to better document the surface emissions using near surface gas monitoring, understand the origin of the gas through major gas composition and stable and noble gas isotopes and improve understanding of the structural controls on gas leakage through mapping. In addition the impact of the leaking CO2 on local water sources (surface and ground) is being investigated, along with the seismic activity of the fault. The investigation will help to build technical capacity in South Africa and to develop monitoring techniques and plans for a future CO2 storage pilot there. Early results suggest that CO2 leakage is confined to a relatively small number of spatially-restricted locations along the weakly seismically active fault. Fracture permeability appears to be the main method by which the CO2 migrates to the surface. The bulk of the CO2 is of deep origin with a minor contribution from near surface biogenic processes as determined by major gas composition. Water chemistry, including pH, DO and TDS is notably different between CO2-rich and CO2-poor sites. Soil gas content and flux effectively delineates the fault trace in active leakage sites. The fault provides an effective testing ground for

  16. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  17. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  18. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  19. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario

    Directory of Open Access Journals (Sweden)

    Jing Ma

    2017-11-01

    Full Text Available The technology of carbon dioxide (CO2 capture and storage (CCS has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO2 geological storage was designed to investigate the short-term effects of different CO2 leakage concentration (from 400 g m−2 day−1 to 2,000 g m−2 day−1 on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO2 concentrations. Increasing CO2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 (p < 0.05. Nitrate nitrogen content varied from 1.01 to 4.03 mg/Kg, while Olsen-phosphorus and total phosphorus demonstrated less regular downtrends. The fluorescein diacetate (FDA hydrolytic enzyme activity was inhibited by the increasing CO2 flux, with the average content varying from 22.69 to 11.25 mg/(Kg h (p < 0.05. However, the increasing activity amplitude of the polyphenol oxidase enzyme approached 230%, while the urease activity presented a similar rising trend. Alpha diversity results showed that the Shannon index decreased from 7.66 ± 0.13 to 5.23 ± 0.35 as the soil CO2 concentration increased. The dominant phylum in the soil samples was Proteobacteria, whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% (p < 0.01. Moreover, the abundances of genera Methylophilus, Methylobacillus, and Methylovorus increased, while GP4, GP6 and GP7 decreased. Canonical correlation analysis

  20. Solution of the finite Milne problem in stochastic media with RVT Technique

    Science.gov (United States)

    Slama, Howida; El-Bedwhey, Nabila A.; El-Depsy, Alia; Selim, Mustafa M.

    2017-12-01

    This paper presents the solution to the Milne problem in the steady state with isotropic scattering phase function. The properties of the medium are considered as stochastic ones with Gaussian or exponential distributions and hence the problem treated as a stochastic integro-differential equation. To get an explicit form for the radiant energy density, the linear extrapolation distance, reflectivity and transmissivity in the deterministic case the problem is solved using the Pomraning-Eddington method. The obtained solution is found to be dependent on the optical space variable and thickness of the medium which are considered as random variables. The random variable transformation (RVT) technique is used to find the first probability density function (1-PDF) of the solution process. Then the stochastic linear extrapolation distance, reflectivity and transmissivity are calculated. For illustration, numerical results with conclusions are provided.

  1. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    International Nuclear Information System (INIS)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2009-01-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  2. Anastomotic leakage after esophageal resection: new treatment options by endoluminal vacuum therapy.

    Science.gov (United States)

    Weidenhagen, Rolf; Hartl, Wolfgang H; Gruetzner, Klaus U; Eichhorn, Martin E; Spelsberg, Fritz; Jauch, Karl W

    2010-11-01

    Anastomotic leakage after esophagectomy is an important determinant of early and late morbidity and mortality. Control of the septic focus is essential when treating patients with anastomotic leakages. Surgical and endoscopic treatment options are limited. Between 2005 and 2009, we treated 6 patients who experienced an intrathoracic anastomotic leakage after esophageal resection. After all established therapeutic measures had failed, we explored the feasibility of an endoscopically assisted mediastinal vacuum therapy. We were able to heal intrathoracic esophageal leakages in all 6 patients without any local complications and without the need for reoperation. One patient died because of a progressive pneumonia. Endoscopic vacuum-assisted closure of anastomotic leakages may help to overcome the limitations that are associated with intermittent endoscopic treatment and conventional drainage therapy. Our preliminary results suggest that this new concept may be suitable for those patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Integrating Flexible Sensor and Virtual Self-Organizing DC Grid Model With Cloud Computing for Blood Leakage Detection During Hemodialysis.

    Science.gov (United States)

    Huang, Ping-Tzan; Jong, Tai-Lang; Li, Chien-Ming; Chen, Wei-Ling; Lin, Chia-Hung

    2017-08-01

    Blood leakage and blood loss are serious complications during hemodialysis. From the hemodialysis survey reports, these life-threatening events occur to attract nephrology nurses and patients themselves. When the venous needle and blood line are disconnected, it takes only a few minutes for an adult patient to lose over 40% of his / her blood, which is a sufficient amount of blood loss to cause the patient to die. Therefore, we propose integrating a flexible sensor and self-organizing algorithm to design a cloud computing-based warning device for blood leakage detection. The flexible sensor is fabricated via a screen-printing technique using metallic materials on a soft substrate in an array configuration. The self-organizing algorithm constructs a virtual direct current grid-based alarm unit in an embedded system. This warning device is employed to identify blood leakage levels via a wireless network and cloud computing. It has been validated experimentally, and the experimental results suggest specifications for its commercial designs. The proposed model can also be implemented in an embedded system.

  4. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  5. Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; He, Ran; Jian, Jiamin

    2016-01-01

    Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism...... of the leakage current is clearly identified. Different typical carrier-based modulation methods and their corresponding common mode voltages are discussed. A new modulation strategy with Boolean logic function is proposed to achieve the constant common mode voltage for the leakage current reduction. Finally...

  6. A Framework to Implement IoT Network Performance Modelling Techniques for Network Solution Selection.

    Science.gov (United States)

    Delaney, Declan T; O'Hare, Gregory M P

    2016-12-01

    No single network solution for Internet of Things (IoT) networks can provide the required level of Quality of Service (QoS) for all applications in all environments. This leads to an increasing number of solutions created to fit particular scenarios. Given the increasing number and complexity of solutions available, it becomes difficult for an application developer to choose the solution which is best suited for an application. This article introduces a framework which autonomously chooses the best solution for the application given the current deployed environment. The framework utilises a performance model to predict the expected performance of a particular solution in a given environment. The framework can then choose an apt solution for the application from a set of available solutions. This article presents the framework with a set of models built using data collected from simulation. The modelling technique can determine with up to 85% accuracy the solution which performs the best for a particular performance metric given a set of solutions. The article highlights the fractured and disjointed practice currently in place for examining and comparing communication solutions and aims to open a discussion on harmonising testing procedures so that different solutions can be directly compared and offers a framework to achieve this within IoT networks.

  7. A Framework to Implement IoT Network Performance Modelling Techniques for Network Solution Selection

    Directory of Open Access Journals (Sweden)

    Declan T. Delaney

    2016-12-01

    Full Text Available No single network solution for Internet of Things (IoT networks can provide the required level of Quality of Service (QoS for all applications in all environments. This leads to an increasing number of solutions created to fit particular scenarios. Given the increasing number and complexity of solutions available, it becomes difficult for an application developer to choose the solution which is best suited for an application. This article introduces a framework which autonomously chooses the best solution for the application given the current deployed environment. The framework utilises a performance model to predict the expected performance of a particular solution in a given environment. The framework can then choose an apt solution for the application from a set of available solutions. This article presents the framework with a set of models built using data collected from simulation. The modelling technique can determine with up to 85% accuracy the solution which performs the best for a particular performance metric given a set of solutions. The article highlights the fractured and disjointed practice currently in place for examining and comparing communication solutions and aims to open a discussion on harmonising testing procedures so that different solutions can be directly compared and offers a framework to achieve this within IoT networks.

  8. Leakage Account for Radial Face Contact Seal in Aircraft Engine Support

    Science.gov (United States)

    Vinogradov, A. S.; Sergeeva, T. V.

    2018-01-01

    The article is dedicated to the development of a methodology for the radial face contact seal design taking into consideration the supporting elements deformations in different aircraft engine operating modes. Radial face contact seals are popular in the aircraft engines bearing support. However, there are no published leakage calculation methodologies of these seals. Radial face contact seal leakage is determined by the gap clearance in the carbon seal ring split. In turn, the size gap clearance depends on the deformation of the seal assembly parts and from the engine operation. The article shows the leakage detection sequence in the intershaft radial face contact seal of the compressor support for take-off and cruising modes. Evaluated calculated leakage values (2.4 g/s at takeoff and 0.75 g/s at cruising) go with experience in designing seals.

  9. Geochemical Influence on Microbial Communities at CO2-Leakage Analog Sites.

    Science.gov (United States)

    Ham, Baknoon; Choi, Byoung-Young; Chae, Gi-Tak; Kirk, Matthew F; Kwon, Man Jae

    2017-01-01

    Microorganisms influence the chemical and physical properties of subsurface environments and thus represent an important control on the fate and environmental impact of CO 2 that leaks into aquifers from deep storage reservoirs. How leakage will influence microbial populations over long time scales is largely unknown. This study uses natural analog sites to investigate the long-term impact of CO 2 leakage from underground storage sites on subsurface biogeochemistry. We considered two sites with elevated CO 2 levels (sample groups I and II) and one control site with low CO 2 content (group III). Samples from sites with elevated CO 2 had pH ranging from 6.2 to 4.5 and samples from the low-CO 2 control group had pH ranging from 7.3 to 6.2. Solute concentrations were relatively low for samples from the control group and group I but high for samples from group II, reflecting varying degrees of water-rock interaction. Microbial communities were analyzed through clone library and MiSeq sequencing. Each 16S rRNA analysis identified various bacteria, methane-producing archaea, and ammonia-oxidizing archaea. Both bacterial and archaeal diversities were low in groundwater with high CO 2 content and community compositions between the groups were also clearly different. In group II samples, sequences classified in groups capable of methanogenesis, metal reduction, and nitrate reduction had higher relative abundance in samples with relative high methane, iron, and manganese concentrations and low nitrate levels. Sequences close to Comamonadaceae were abundant in group I, while the taxa related to methanogens, Nitrospirae , and Anaerolineaceae were predominant in group II. Our findings provide insight into subsurface biogeochemical reactions that influence the carbon budget of the system including carbon fixation, carbon trapping, and CO 2 conversion to methane. The results also suggest that monitoring groundwater microbial community can be a potential tool for tracking CO 2

  10. Geochemical Influence on Microbial Communities at CO2-Leakage Analog Sites

    Directory of Open Access Journals (Sweden)

    Baknoon Ham

    2017-11-01

    Full Text Available Microorganisms influence the chemical and physical properties of subsurface environments and thus represent an important control on the fate and environmental impact of CO2 that leaks into aquifers from deep storage reservoirs. How leakage will influence microbial populations over long time scales is largely unknown. This study uses natural analog sites to investigate the long-term impact of CO2 leakage from underground storage sites on subsurface biogeochemistry. We considered two sites with elevated CO2 levels (sample groups I and II and one control site with low CO2 content (group III. Samples from sites with elevated CO2 had pH ranging from 6.2 to 4.5 and samples from the low-CO2 control group had pH ranging from 7.3 to 6.2. Solute concentrations were relatively low for samples from the control group and group I but high for samples from group II, reflecting varying degrees of water-rock interaction. Microbial communities were analyzed through clone library and MiSeq sequencing. Each 16S rRNA analysis identified various bacteria, methane-producing archaea, and ammonia-oxidizing archaea. Both bacterial and archaeal diversities were low in groundwater with high CO2 content and community compositions between the groups were also clearly different. In group II samples, sequences classified in groups capable of methanogenesis, metal reduction, and nitrate reduction had higher relative abundance in samples with relative high methane, iron, and manganese concentrations and low nitrate levels. Sequences close to Comamonadaceae were abundant in group I, while the taxa related to methanogens, Nitrospirae, and Anaerolineaceae were predominant in group II. Our findings provide insight into subsurface biogeochemical reactions that influence the carbon budget of the system including carbon fixation, carbon trapping, and CO2 conversion to methane. The results also suggest that monitoring groundwater microbial community can be a potential tool for tracking

  11. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    International Nuclear Information System (INIS)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja; Im, Hyoung June

    2010-01-01

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  12. Hydrogeochemical impact of CO{sub 2} leakage from geological sequestration on shallow potable aquifers

    Energy Technology Data Exchange (ETDEWEB)

    Cahill, A.G.

    2013-09-15

    with more than 770 water samples taken. In addition pre- and post-injection sediment cores were studied in order to assess sediment alteration and aid identification of controlling geochemical processes. Results show a significant lowering of pH and increase in electrical conductivity, but except for Al concentrations reaching up to 75 {mu}mol/L, the detrimental effects on groundwater quality were limited. Groundwater chemistry evolves spatially and temporally during leakage, thus risks posed and the best methods for detection will also vary. In addition, 2 main phases of leakage were identified; a pulse phase of elevated ions moving with advective flow succeeded by increasing persistent acidification caused by buffering exhaustion (i.e. depletion of reactive minerals). Aqueous element concentrations were delineated into 4 generalized behaviors; 1. advective pulse (Ca, Mg, Na, Si, Ba and Sr,), 2. pH sensitive abundance dependent (Al and Zn), 3. complete removal (Mn and Fe) and 4. unaffected (K). Concentration behaviors were characterized by; 1. a maximal front moving with advective flow, 2. continual increase in close proximity to the injection horizon, 3. removal from solution to zero concentration and 4. no significant change. Paper IV describes geochemical modeling conducted in support of field and laboratory activities and proposes that gibbsite derived Al{sup 3+} driven cation exchange can explain the majority of the water chemistry evolution at Vroegum. In addition buffering exhaustion/sediment depletion is corroborated explaining increasing acidification observed. Results infer risks associated with and how best to detect leakage will change with time and also increase with depth. Consequently water quality may become more deleterious as a leak matures and will vary with depth. (Author)

  13. Cumulative Impacts of Energy and Climate Change Policies on Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Varma, A.; Milnes, R.; Miller, K.; Williams, E. [AEA Technology plc, London (United Kingdom); De Bruyn, S.; Brinke, L. [CE Delft, Delft (Netherlands)

    2012-02-15

    Carbon leakage occurs when climate change policy aimed at reducing carbon dioxide emissions in one country leads to an increase in carbon dioxide emissions in a country that is not bound by these policies. Given that climate change is a global issue, carbon leakage impacts upon the effectiveness of climate change policies. This independent study examines the cumulative impact of climate change policies on carbon leakage. The report brings together findings and analysis from a wide range of primary literature in this area and where possible, conclusions relevant to the UK are drawn.

  14. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  15. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  16. Non-fistulous urinary leakage among women attending a Nigerian family planning clinic

    Directory of Open Access Journals (Sweden)

    Ijaiya MA

    2011-12-01

    Full Text Available Munir'deen A Ijaiya1, Hadijat O Raji1, Abiodun P Aboyeji1, Kike T Adesina1, Idowu O Adebara2, Grace G Ezeoke11Department of Obstetrics and Gynaecology, University of Ilorin Teaching Hospital, Ilorin, Nigeria; 2Department of Obstetrics and Gynaecology, Federal Medical Centre, Ido-Ekiti, NigeriaAbstract: Urinary leakage is an important gynecological challenge, which has a substantial impact on quality of life. The aim of this study was to determine the prevalence and types of non-fistulous urinary leakage among women attending the family planning clinic of the University of Ilorin teaching hospital, Ilorin, Nigeria. The study was a cross-sectional study carried out between January 3 and April 25 2009. One hundred and two women experienced urinary leakage out of 333 women interviewed, giving a prevalence rate of 30.6%. Stress incontinence was the most common urinary leakage (prevalence rate 12.0%. This is followed by urge incontinence (10.8%, urinary incontinence (4.8%, and overflow incontinence (3.0%. None of the women afflicted sought medical help. Conclusively, this study has demonstrated that non-fistulous urinary leakage is a common problem among women of reproductive age in this environment.Keywords: non-fistulous urinary leakage, family planning, women, prevalence, types

  17. Leak detection of complex pipelines based on the filter diagonalization method: robust technique for eigenvalue assessment

    International Nuclear Information System (INIS)

    Lay-Ekuakille, Aimé; Pariset, Carlo; Trotta, Amerigo

    2010-01-01

    The FDM (filter diagonalization method), an interesting technique used in nuclear magnetic resonance data processing for tackling FFT (fast Fourier transform) limitations, can be used by considering pipelines, especially complex configurations, as a vascular apparatus with arteries, veins, capillaries, etc. Thrombosis, which might occur in humans, can be considered as a leakage for the complex pipeline, the human vascular apparatus. The choice of eigenvalues in FDM or in spectra-based techniques is a key issue in recovering the solution of the main equation (for FDM) or frequency domain transformation (for FFT) in order to determine the accuracy in detecting leaks in pipelines. This paper deals with the possibility of improving the leak detection accuracy of the FDM technique thanks to a robust algorithm by assessing the problem of eigenvalues, making it less experimental and more analytical using Tikhonov-based regularization techniques. The paper starts from the results of previous experimental procedures carried out by the authors

  18. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  19. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  20. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  1. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.

  2. Research on leakage detection of nuclear power station primary loop

    International Nuclear Information System (INIS)

    Cao Shengquan; Yang Jicai; Li Jianjun; Dong Zhijuan; Ren Juyan; Zhang Pinyuan

    1993-01-01

    The sensor of leak-detection system is a special humidity-sensitive element. In this system, the collection and treatment of detected data, and the leakage alarm are controlled by a simple board computer. The three parameters A, B and C are set up in this system, and the alarm will give out when signal surpasses values of B and C at the same time. The effects of environment humidity and temperature on collection of detected data are considered, and the leakage alarm is reliable. When the leakage rate of water at 320 degree C and 12.2 MPa is 0.3 g/min, the alarm signal will sent out within 5 s

  3. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  4. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection.

    Science.gov (United States)

    Martin, Douglas J; Rad, Arash Ehteshami; Kallmes, David F

    2012-06-01

    Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, postprocedure plain radiographs, and postprocedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and prevertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ(2) test. One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34%, 95% CI 28-42%) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P = 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n = 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and prevertebral venous (n = 32, 18%, 95% CI 13-24%). Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography.

  5. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    International Nuclear Information System (INIS)

    Kariya, Shuji; Nakatani, Miyuki; Yoshida, Rie; Ueno, Yutaka; Komemushi, Atsushi; Tanigawa, Noboru

    2017-01-01

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  6. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp; Ueno, Yutaka, E-mail: uenoyut@hirakata.kmu.ac.jp; Komemushi, Atsushi, E-mail: komemush@takii.kmu.ac.jp; Tanigawa, Noboru, E-mail: tanigano@hirakata.kmu.ac.jp [Kansai Medical University, Department of Radiology (Japan)

    2017-01-15

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  7. Leakage Risk Assessment for a Potential CO2 Storage Project in Saskatchewan, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Houseworth, J.E.; Oldenburg, C.M.; Mazzoldi, A.; Gupta, A.K.; Nicot, J.-P.; Bryant, S.L.

    2011-05-01

    A CO{sub 2} sequestration project is being considered to (1) capture CO{sub 2} emissions from the Consumers Cooperative Refineries Limited at Regina, Saskatchewan and (2) geologically sequester the captured CO{sub 2} locally in a deep saline aquifer. This project is a collaboration of several industrial and governmental organizations, including the Petroleum Technology Research Centre (PTRC), Sustainable Development Technology Canada (SDTC), SaskEnvironment Go Green Fund, SaskPower, CCRL, Schlumberger Carbon Services, and Enbridge. The project objective is to sequester 600 tonnes CO{sub 2}/day. Injection is planned to start in 2012 or 2013 for a period of 25 years for a total storage of approximately 5.5 million tonnes CO{sub 2}. This report presents an assessment of the leakage risk of the proposed project using a methodology known as the Certification Framework (CF). The CF is used for evaluating CO{sub 2} leakage risk associated with geologic carbon sequestration (GCS), as well as brine leakage risk owing to displacement and pressurization of brine by the injected CO{sub 2}. We follow the CF methodology by defining the entities (so-called Compartments) that could be impacted by CO{sub 2} leakage, the CO{sub 2} storage region, the potential for leakage along well and fault pathways, and the consequences of such leakage. An understanding of the likelihood and consequences of leakage forms the basis for understanding CO{sub 2} leakage risk, and forms the basis for recommendations of additional data collection and analysis to increase confidence in the risk assessment.

  8. Preoperative risk factors for anastomotic leakage after resection for colorectal cancer

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian; Gessler, B; Burcharth, Jakob

    2014-01-01

    AIM: Colorectal anastomotic leakage is a serious complication. Despite extensive research, no consensus on the most important preoperative risk factors exists. The aim of this systematic review and meta-analysis was to evaluate risk factors for anastomotic leakage in patients operated with colore...

  9. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  10. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  11. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    Science.gov (United States)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  12. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    Science.gov (United States)

    White, Curt [Pittsburgh, PA; Wells, Arthur [Bridgeville, PA; Diehl, J Rodney [Pittsburgh, PA; Strazisar, Brian [Venetia, PA

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  13. Use of isotopes techniques during the life cycle of dams and reservoirs: cases in Latin American

    International Nuclear Information System (INIS)

    Leon, S.H.

    2006-01-01

    In fact, the combined use of isotope and conventional techniques is considered a reliable tool for studying problems related to dam safety and has become a new culture for civil / dam engineers, hydro geologists and researchers who involve in water resource management fields. The use of natural (environmental) and artificial isotopes as tracers together with systematic analyses of the hydrochemistry, electrical conductivity and temperature profiles data during the investigation and monitoring of leakage and seepage in dams and reservoirs are now becoming popular among the dam owners in seeking the best solution for dam related problems. Many studies and experiences worldwide on effective dam management programmes have indicated that any investigation about leakages and seepages are not possible to be accomplished successfully without synergic application of the conventional technologies and isotopic techniques. The major advancement in this area is the measurements study for establishment of baseline hydrogeology at each hydraulic work project like dams and reservoirs. The parameters include hydro chemicals, isotopic and geologic in each basin, river, reservoir, dams, tunnels and groundwater which provide high value information for decision making during all the stages in the life cycle of the dams. Many hydroelectric and water supply projects in latin america apply these investigation strategies. The main target is to investigate and understand the water movement around the dam and its vicinity. Then the specialised work teams will decide for the effective and economic monitoring activities and the implementation of the recommended remedial measures to ensure high standards of safety and security of the large dams and reservoirs. A typical example of specific leakage investigation of la Honda dam is briefly discussed. (Author)

  14. Application of thermometric methods for detection and characterization of leakages in embankment dams

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Y.L.; Cunat, P.; Fry, J.J. [EDF, Grenoble (France); Faure, Y.H. [LTHE, Saint Martin d' Heres (France)

    2010-07-01

    The earliest possible detection of leakages in dikes is essential. Distributed temperature measurements using fibre optics allow the monitoring of large sections of the dike with a high spatial and temperature resolution. This paper presented the application of thermometric methods for detection and characterization of leakage in embankment dams. After a brief description of the system used, its application on a controlled experimental site and an EDF industrial site instrumented with fibre optics was presented. The instrumentation is complemented by installation of local temperature and pressure sensors in the piezometers for complete characterization of the detected leakages. The analysis of the results data clearly allowed detecting the leakages. The vertical location, intensity and location of the detected leakages were also identified. It was found that thermometry is potentially very powerful for detecting leaks and as a diagnostic tool.

  15. Increased risk of anastomotic leakage with diclofenac treatment after laparoscopic colorectal surgery

    DEFF Research Database (Denmark)

    Klein, Mads; Andersen, Lars Peter Holst; Harvald, Thomas

    2009-01-01

    BACKGROUND: Over a period our department experienced an unexpected high frequency of anastomotic leakages. After diclofenac was removed from the postoperative analgesic regimen, the frequency dropped. This study aimed to evaluate the influence of diclofenac on the risk of developing anastomotic...... leakage after laparoscopic colorectal surgery. METHODS: This was a retrospective case-control study based on 75 consecutive patients undergoing laparoscopic colorectal resection with primary anastomosis. In period 1, patients received diclofenac 150 mg/day. In period 2, diclofenac was withdrawn...... and the patients received an opioid analgesic instead. The primary outcome parameter was clinically significant anastomotical leakage verified at reoperation. RESULTS: 1/42 patients in the no-diclofenac group compared with 7/33 in the diclofenac group had an anastomotic leakage after operation (p = 0...

  16. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  17. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    Energy Technology Data Exchange (ETDEWEB)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H. [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH{sub T} was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle.

  18. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    International Nuclear Information System (INIS)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H.

    2016-01-01

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH_T was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle

  19. Highly Reliable Transformerless Photovoltaic Inverters With Leakage Current and Pulsating Power Elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Loh, Poh Chiang

    2016-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common-mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Furthermore, the proposed inverter can also eliminate the well-known double-line-frequency pulsating...... power that is inherent in single-phase PV systems. By properly injecting CM voltages to the output filter capacitors, the pulsating power can be decoupled from the dc-link. Therefore, it is possible to use long-lifetime film capacitors instead of electrolytic capacitors to improve the reliability...

  20. Oil leakage detection for electric power equipment based on ultraviolet fluorescence effect

    Science.gov (United States)

    Zhang, Jing; Wang, Jian-hui; Xu, Bin; Huang, Zhi-dong; Huang, Lan-tao

    2018-03-01

    This paper presents a method to detect the oil leakage of high voltage power equipment based on ultraviolet fluorescence effect. The method exploits the principle that the insulating oil has the fluorescent effect under the irradiation of specific ultraviolet light. The emission spectrum of insulating oil under excitation light with different wavelengths is measured and analyzed first. On this basis, a portable oil leakage detective device for high voltage power equipment is designed and developed with a selected 365 nm ultraviolet as the excitation light and the low light level camera as the fluorescence image collector. Then, the feasibility of the proposed method and device in different conditions is experimentally verified in the laboratory environment. Finally, the developed oil leakage detective device is applied to 500 kV Xiamen substation and Quanzhou substation. And the results show that the device can detect the oil leakage of high voltage electrical equipment quickly and conveniently even under the condition of a slight oil leakage especially in the low light environment.

  1. Effectiveness of EDTA as the irrigation solution to remove smear layer in root canal

    Directory of Open Access Journals (Sweden)

    Kurniasri Amas Achiar

    2009-07-01

    Full Text Available One of the objectives of successful endodontic treatment is the hermetic obturation of the root canal system. To achieve this, the root canal filling must seal the canal space both apically and coronally to prevent the ingress of microorganisms or tissue fluids into the canal space. Apical leakage is reported a common reason for the clinical failure of endodontic therapy. Leakage through an obturated root canal is expected to take place at interfaces between sealer and dentin or sealer and gutta-percha, or through voids within the sealer. Hence, the sealing quality of root canal filling depends much on the sealing ability of the sealer. Therefore, anything that may influence the adaptation of the root filling to the canal wall is can determine the degree and the extent of leakage, and ultimately the prognosis of the endodontic therapy. In endodontic therapy, the smear layer formation results from root canal preparation and may influence the effective seal of the root canal system. The smear layer formation is mainly composed of inorganic components (dentin debris and organic materials, such as pulp tissue remnant, bacteria, and blood cells. Removal of the smear layer from the root canal walls before the obturation can reduce the leakage of root canal sealer. To remove the smear layer use 10 ml 17% EDTA followed by 10 ml of 5.25% NaOCl as irrigating solution. This paper discribe about how the effectivity of EDTA as irigating solution to remove the smear layer especially in the apical root canal with many lateral canal to reduce the apical leakage.

  2. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  3. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  4. Flow shop scheduling decisions through Techniques for Order Preference by Similarity to an Ideal Solution (TOPSIS

    Directory of Open Access Journals (Sweden)

    Arun Gupta

    2016-07-01

    Full Text Available The flow-shop scheduling problem (FSP has been widely studied in the literature and having a very active research area. Over the last few decades, a number of heuristic/meta-heuristic solution techniques have been developed. Some of these techniques offer excellent effectiveness and efficiency at the expense of substantial implementation efforts and being extremely complicated. This paper brings out the application of a Multi-Criteria Decision Making (MCDM method known as techniques for order preference by similarity to an ideal solution (TOPSIS using different weighting schemes in flow-shop environment. The objective function is identification of a job sequence which in turn would have minimum makespan (total job completion time. The application of the proposed method to flow shop scheduling is presented and explained with a numerical example. The results of the proposed TOPSIS based technique of FSP are also compared on the basis of some benchmark problems and found compatible with the results obtained from other standard procedures.

  5. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  6. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  7. On an asymptotic technique of solution of the inverse problem of helioseismology

    International Nuclear Information System (INIS)

    Brodskij, M.A.; Vorontsov, S.V.

    1987-01-01

    The technique for the solution of the universe problem for the solar 5-min. oscillations is proposed, which provides an independent determination of the second speed as a function of depth in solar interior and the frequency dependence of the effective phase shift for the reflection of the trapped acoustic waves from the outer layers. The preliminary numerical results are presented

  8. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection

    International Nuclear Information System (INIS)

    Martin, Douglas J.; Rad, Arash Ehteshami; Kallmes, David F.

    2012-01-01

    Background: Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. Purpose: To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, post procedure plain radiographs, and post procedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. Material and Methods: With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and pre vertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ 2 test. Results: One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34 %, 95 % CI 28-42 %) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and pre vertebral venous (n = 32, 18%, 95% CI 13-24%). Conclusion: Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography

  9. Root cause evaluation of pressurizer relief valve leakage

    International Nuclear Information System (INIS)

    Olson, D.E.; Voll, B.J.

    1996-01-01

    Pressurizer relief valves at two pressurized water reactor units experienced unacceptable leakage during plant heatup. The leakage was suspected to be caused by excessive pipe loads on the valves. This paper describes how monitoring via hard-wired transducers and a digital data acquisition system was used to quantify the pipe loads on the valves, and assist in determining the root cause of the pipe loads and appropriate corrective actions. The selection of the parameters monitored, how the monitoring was accomplished and interpretation of the results is discussed. The corrective actions implemented based on the monitoring results are also discussed

  10. Marginal Micro-leakage of Self-etch and All-in One Adhesives to Primary Teeth, with Mechanical or Chemo-Mechanical Caries Removal

    Directory of Open Access Journals (Sweden)

    Nouzari A

    2016-06-01

    Full Text Available Statement of Problem: Chemo-mechanical caries removal is an effective alternative to the traditional rotary drilling method. One of the factors that can influence micro-leakage is the method of caries removal. Objectives: To compare the micro-leakage of resin composite in primary dentition using self-etch and all-in one adhesives following conventional and chemo-mechanical caries removal. Materials and Methods: Sixty extracted human primary anterior teeth with class III carious lesions were collected. The selected teeth were divided randomly into two groups each consisting of 30 teeth. In group1 carious lesions were removed using Carisolv multi mix gel. In group 2, caries was removed using round steel burs in a slow–speed hand piece. Then, the specimens in each group were randomly divided into two subgroups (A and B of 15 and treated by either Clearfil SE Bond (CSEB or Scotch bond. All prepared cavities were filled with a resin composite (Estellite. All the specimens were stored in distilled water at 37ºC for 24 hours and then thermocycled in 5ºC and 55ºC water with a dwell time of 20 seconds for 1500 cycles. The specimens were immersed in 1% methylene blue solution for 24 hours, removed, washed and sectioned mesiodistally. The sectioned splits were examined under a stereomicroscope to determine the micro-leakage scores. The data were analyzed using Kruskal-Wallis Test in SPSS version 21. Results: There were no significant differences between micro-leakage scores among the four groups (p = 0.127. Score 0 of micro-leakage was detected for 60% of the specimens in group 1-A (Carisolv + CSEB, 73% of the group 2-A (hand piece + CSEB, 80% of the group 1-B (Carisolv + Scotch bond, and 93% of the group 2-B in which caries was removed using hand piece and bonded with Scotch bond . Conclusions: Although caries removal using hand piece bur along with using Scotch bond adhesive performed less micro-leakage, it would seems that the use of Carisolv

  11. Semi-analytical solutions for flow to a well in an unconfined-fractured aquifer system

    Science.gov (United States)

    Sedghi, Mohammad M.; Samani, Nozar

    2015-09-01

    Semi-analytical solutions of flow to a well in an unconfined single porosity aquifer underlain by a fractured double porosity aquifer, both of infinite radial extent, are obtained. The upper aquifer is pumped at a constant rate from a pumping well of infinitesimal radius. The solutions are obtained via Laplace and Hankel transforms and are then numerically inverted to time domain solutions using the de Hoog et al. algorithm and Gaussian quadrature. The results are presented in the form of dimensionless type curves. The solution takes into account the effects of pumping well partial penetration, water table with instantaneous drainage, leakage with storage in the lower aquifer into the upper aquifer, and storativity and hydraulic conductivity of both fractures and matrix blocks. Both spheres and slab-shaped matrix blocks are considered. The effects of the underlying fractured aquifer hydraulic parameters on the dimensionless drawdown produced by the pumping well in the overlying unconfined aquifer are examined. The presented solution can be used to estimate hydraulic parameters of the unconfined and the underlying fractured aquifer by type curve matching techniques or with automated optimization algorithms. Errors arising from ignoring the underlying fractured aquifer in the drawdown distribution in the unconfined aquifer are also investigated.

  12. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  13. Two applications of airtightness control techniques on big assemblies

    CERN Document Server

    Devallan, C; Marcellin, J

    1973-01-01

    Deals with two airtightness control techniques respectively applied on intersecting storage rings (ISR) at CERN in Geneva and on a liquid methane storage tank. These two big assemblies called for two different control techniques which use helium and ammonia respectively as tracer gas. Existing practical leakage detection techniques to meet industrial needs are discussed at the end of the article. (2 refs).

  14. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  15. A conservation planning approach to mitigate the impacts of leakage from protected area networks.

    Science.gov (United States)

    Bode, Michael; Tulloch, Ayesha I T; Mills, Morena; Venter, Oscar; Ando, Amy W

    2015-06-01

    Protected area networks are designed to restrict anthropogenic pressures in areas of high biodiversity. Resource users respond by seeking to replace some or all of the lost resources from locations elsewhere in the landscape. Protected area networks thereby perturb the pattern of human pressures by displacing extractive effort from within protected areas into the broader landscape, a process known as leakage. The negative effects of leakage on conservation outcomes have been empirically documented and modeled using homogeneous descriptions of conservation landscapes. Human resource use and biodiversity vary greatly in space, however, and a theory of leakage must describe how this heterogeneity affects the magnitude, pattern, and biodiversity impacts of leakage. We combined models of household utility, adaptive human foraging, and biodiversity conservation to provide a bioeconomic model of leakage that accounts for spatial heterogeneity. Leakage had strong and divergent impacts on the performance of protected area networks, undermining biodiversity benefits but mitigating the negative impacts on local resource users. When leakage was present, our model showed that poorly designed protected area networks resulted in a substantial net loss of biodiversity. However, the effects of leakage can be mitigated if they are incorporated ex-ante into the conservation planning process. If protected areas are coupled with nonreserve policy instruments such as market subsidies, our model shows that the trade-offs between biodiversity and human well-being can be further and more directly reduced. © 2014 Society for Conservation Biology.

  16. Determination of boron in aqueous solutions by solid state nuclear track detectors technique, using a filtered neutron beam

    International Nuclear Information System (INIS)

    Moraes, M.A.P.V. de; Pugliesi, R.; Khouri, M.T.F.C.

    1985-11-01

    The solid state nuclear track detectors technique has been used for determination of boron in aqueous solutions, using a filtered neutron beam. The particles tracks from the 10 B(n,α)Li 7 reaction were registered in the CR-39 film, chemically etched in a (30%) KOH solution 70 0 C during 90 minutes. The obtained results showed the usefulness of this technique for boron determination in the ppm range. The inferior detectable limit was 9 ppm. The combined track registration efficiency factor K has been evaluated in the solutions, for the CR-39 detector and its values is K= (4,60 - + 0,06). 10 -4 cm. (Author) [pt

  17. Early detection of anastomotic leakage after elective low anterior resection.

    Science.gov (United States)

    Fouda, Elyamani; El Nakeeb, Ayman; Magdy, Alaa; Hammad, Enas A; Othman, Gamal; Farid, Mohamed

    2011-01-01

    Colorectal anastomotic leakage is a serious complication leading to major postoperative morbidity and mortality. In the present study, we investigated the early detection of anastomotic leakage before its clinical presentation. Fifty-six patients with rectal cancer were included prospectively in this study. All patients underwent elective low anterior resection. Peritoneal samples were collected from the abdominal drains at the first, third, and fifth days postoperatively for bacteriological study (quantitative cultures for both aerobes and anaerobes) and cytokines (IL-6, IL-10, TNF) measurement. Patients were divided into two groups: those without symptomatic or clinical evidence of anastomotic leakage (AL; group 1) and those with clinical evidence of AL (group 2). Study variables included hospital stay, wound infection, operative time, blood loss, height of anastomosis, intraperitoneal cytokines, and microbiological study of peritoneal fluid. Clinically evident AL occurred in eight patients (14.3%) and diagnosed postoperatively on median day 6. Intraperitoneal bacterial colonization and cytokine levels were significantly higher in patients with clinical evidence of AL. Wound infection was significantly higher in anastomotic leakage group. The hospital stay for the patients with anastomotic leakage was significantly longer than those without AL (14 ± 1.41 vs. 5.43 ± 0.89 days). A significant difference among two groups was observed regarding operative time, blood loss, blood transfusion, and height of the anastomosis. The peritoneal cytokines levels and intraperitoneal bacterial colonization might be an additional diagnostic tool that can support the decision making of surgeons for early detection of anastomotic leak in colorectal surgery.

  18. A proposed scalable design and simulation of wireless sensor network-based long-distance water pipeline leakage monitoring system.

    Science.gov (United States)

    Almazyad, Abdulaziz S; Seddiq, Yasser M; Alotaibi, Ahmed M; Al-Nasheri, Ahmed Y; BenSaleh, Mohammed S; Obeid, Abdulfattah M; Qasim, Syed Manzoor

    2014-02-20

    Anomalies such as leakage and bursts in water pipelines have severe consequences for the environment and the economy. To ensure the reliability of water pipelines, they must be monitored effectively. Wireless Sensor Networks (WSNs) have emerged as an effective technology for monitoring critical infrastructure such as water, oil and gas pipelines. In this paper, we present a scalable design and simulation of a water pipeline leakage monitoring system using Radio Frequency IDentification (RFID) and WSN technology. The proposed design targets long-distance aboveground water pipelines that have special considerations for maintenance, energy consumption and cost. The design is based on deploying a group of mobile wireless sensor nodes inside the pipeline and allowing them to work cooperatively according to a prescheduled order. Under this mechanism, only one node is active at a time, while the other nodes are sleeping. The node whose turn is next wakes up according to one of three wakeup techniques: location-based, time-based and interrupt-driven. In this paper, mathematical models are derived for each technique to estimate the corresponding energy consumption and memory size requirements. The proposed equations are analyzed and the results are validated using simulation.

  19. A Proposed Scalable Design and Simulation of Wireless Sensor Network-Based Long-Distance Water Pipeline Leakage Monitoring System

    Directory of Open Access Journals (Sweden)

    Abdulaziz S. Almazyad

    2014-02-01

    Full Text Available Anomalies such as leakage and bursts in water pipelines have severe consequences for the environment and the economy. To ensure the reliability of water pipelines, they must be monitored effectively. Wireless Sensor Networks (WSNs have emerged as an effective technology for monitoring critical infrastructure such as water, oil and gas pipelines. In this paper, we present a scalable design and simulation of a water pipeline leakage monitoring system using Radio Frequency IDentification (RFID and WSN technology. The proposed design targets long-distance aboveground water pipelines that have special considerations for maintenance, energy consumption and cost. The design is based on deploying a group of mobile wireless sensor nodes inside the pipeline and allowing them to work cooperatively according to a prescheduled order. Under this mechanism, only one node is active at a time, while the other nodes are sleeping. The node whose turn is next wakes up according to one of three wakeup techniques: location-based, time-based and interrupt-driven. In this paper, mathematical models are derived for each technique to estimate the corresponding energy consumption and memory size requirements. The proposed equations are analyzed and the results are validated using simulation.

  20. Preliminary Study of Magnetic Flux Leakage on Tube Inspection

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Ilham Mukriz Zainal Abidin; Nurul Ain Ahmad Latif

    2015-01-01

    Magnetic Flux Leakage (MFL) is an advanced NDT technique which has the inspection capability in wall loss detection and measurement of sharp defects such as pitting, grooving and circumferential cracks in ferromagnetic samples. The working principle of MFL involves the induction of magnetic field in the part to be tested and the response or signal produced is analysed to determine the presence and characteristics of defects. In this paper, simulation and experimental work on wall loss detection in steel tube using MFL were carried out. The simulation was performed using Comsol software and followed by experimental work using MFL system for validation. The results from the simulation and experiment indicates that variation of the groove defect affect the magnetisation and the output of the MFL signal is related to change of flux caused by the detection of wall loss. (author)

  1. Modelling of Leakage Current Through Double Dielectric Gate Stack in Metal Oxide Semiconductor Capacitor

    International Nuclear Information System (INIS)

    Fatimah A Noor; Mikrajuddin Abdullah; Sukirno; Khairurrijal

    2008-01-01

    In this paper, we have derived analytical expression of leakage current through double barriers in Metal Oxide Semiconductor (MOS) capacitor. Initially, electron transmittance through the MOS capacitor was derived by including the coupling between the transverse and longitudinal energies. The transmittance was then employed to obtain leakage current through the double barrier. In this model, we observed the effect of electron velocity due to the coupling effect and the oxide thickness to the leakage current. The calculated results showed that the leakage current decreases as the electron velocity increases. (author)

  2. 4D ERT Monitoring of Subsurface Water Pipe Leakage During a Controlled Field Experiment

    Science.gov (United States)

    Inauen, C.; Chambers, J. E.; Wilkinson, P. B.; Meldrum, P.; Swift, R. T.; Uhlemann, S.; Gunn, D.; Dashwood, B.; Taxil, J.; Curioni, G.

    2016-12-01

    Locating and delineating leakage from subsurface pipelines is an important task for civil engineers. 4D Electrical Resistivity Tomography (ERT) allows changes in subsurface resistivity to be imaged at a high spatial and temporal resolution in a minimally invasive manner. It is therefore a promising tool to supplement conventional point-sensing techniques to monitor subsurface flow processes. To assess the efficacy of ERT for pipe leakage monitoring several controlled leak experiments were carried out at a test site in Blagdon, Bristol, UK. To simulate the leak, a plastic pipe with a hole was buried below a flat, grassed area at a depth of 0.7 m, representing a standard UK mains water pipe installation. The water table at the site lies well below the surface meaning that the experiment took entirely place in the vadose zone, where changes in resistivity are primarily sensitive to water content variations. The ERT array covered an area of 6.5m x 6.5m around the leak location. Data acquisition was carried out with the BGS PRIME (Proactive Infrastructure Monitoring and Evaluation) system, which facilitates remote scheduling and autonomous ERT data collection and transmission. To obtain the resistivity changes of the subsurface a 4D inversion was carried out using a Gauss-Newton approach with spatial and temporal smoothness constraints. We were able to reliably observe the onset, spread and cessation of the leakage. Measurements from in-situ soil sensors at several depths above and below the leak complemented the ERT data and allowed us to assess their reliability and directly relate them to hydrogeological processes. Moreover, through experimental tests with soil samples from the test area, a Waxman-Smits relation was obtained to directly convert the changes in electrical resistivity to gravimetric soil moisture content. With future experiments on the test site more work is planned towards survey optimization, automated processing and tracking of leakage plumes.

  3. A numerical technique for enhanced efficiency and stability for the solution of the nuclear reactor equation

    International Nuclear Information System (INIS)

    Khotylev, V.A.; Hoogenboom, J.E.

    1996-01-01

    The paper presents new techniques for the solution of the nuclear reactor equation in diffusion approximation, that has enhanced efficiency and stability. The code system based on the new technique solves a number of steady-state and/or transient problems with coupled thermal hydraulics in one-, two-, or three dimensional geometry with reduced CPU time as compared to similar code systems of previous generations if well-posed neutronics problems are considered. Automated detection of ill-posed problem and selection of the appropriate numerical method makes the new code system capable of yielding a correct solution for wider range of problems without user intervention. (author)

  4. A numerical technique for enhanced efficiency and stability for the solution of the nuclear reactor equation

    Energy Technology Data Exchange (ETDEWEB)

    Khotylev, V.A.; Hoogenboom, J.E. [Delft Univ. of Technology, Interfaculty Reactor Inst., Delft (Netherlands)

    1996-07-01

    The paper presents new techniques for the solution of the nuclear reactor equation in diffusion approximation, that has enhanced efficiency and stability. The code system based on the new technique solves a number of steady-state and/or transient problems with coupled thermal hydraulics in one-, two-, or three dimensional geometry with reduced CPU time as compared to similar code systems of previous generations if well-posed neutronics problems are considered. Automated detection of ill-posed problem and selection of the appropriate numerical method makes the new code system capable of yielding a correct solution for wider range of problems without user intervention. (author)

  5. Polarization leakage in epoch of reionization windows - II. Primary beam model and direction-dependent calibration

    Science.gov (United States)

    Asad, K. M. B.; Koopmans, L. V. E.; Jelić, V.; Ghosh, A.; Abdalla, F. B.; Brentjens, M. A.; de Bruyn, A. G.; Ciardi, B.; Gehlot, B. K.; Iliev, I. T.; Mevius, M.; Pandey, V. N.; Yatawatta, S.; Zaroubi, S.

    2016-11-01

    Leakage of diffuse polarized emission into Stokes I caused by the polarized primary beam of the instrument might mimic the spectral structure of the 21-cm signal coming from the epoch of reionization (EoR) making their separation difficult. Therefore, understanding polarimetric performance of the antenna is crucial for a successful detection of the EoR signal. Here, we have calculated the accuracy of the nominal model beam of Low Frequency ARray (LOFAR) in predicting the leakage from Stokes I to Q, U by comparing them with the corresponding leakage of compact sources actually observed in the 3C 295 field. We have found that the model beam has errors of ≤10 per cent on the predicted levels of leakage of ˜1 per cent within the field of view, I.e. if the leakage is taken out perfectly using this model the leakage will reduce to 10-3 of the Stokes I flux. If similar levels of accuracy can be obtained in removing leakage from Stokes Q, U to I, we can say, based on the results of our previous paper, that the removal of this leakage using this beam model would ensure that the leakage is well below the expected EoR signal in almost the whole instrumental k-space of the cylindrical power spectrum. We have also shown here that direction-dependent calibration can remove instrumentally polarized compact sources, given an unpolarized sky model, very close to the local noise level.

  6. Investigations of leakage mechanisms and its influences on a micro swing engine considering rarefaction effects

    International Nuclear Information System (INIS)

    Zhou, Xiong; Zhang, Zhenyu; Kong, Wenjun; Du, Ning

    2016-01-01

    Highlights: • Mechanisms of the leakage flow in different flow regimes have been studied. • The leakage flow regime and patterns in the micro swing engine are presented. • Slip on the walls has a larger effect on leakage flow with decreasing the gap. • Rarefaction effects on the engine performance have been investigated. - Abstract: Considering rarefaction effects, this paper investigated mechanisms of the clearance leakage and its influences on a micro swing engine for the micro power generation by employing three different flow models named as discrete velocity direction (DVD) model, Navier-Stokes equations with slip boundary conditions (NS-slip) and no-slip boundary conditions (NS-no slip). Using the DVD model, this paper firstly studied leakage mechanisms of a micro Couette-Poisueille flow. Factors which control the leakage in different regimes were obtained. Furthermore, the system-level predictions of the clearance leakage in the micro swing engine have been conducted by solving the Navier-Stokes equations. The leakage flow regime, patterns and characteristics were presented. Results by NS-slip and NS-no slip were compared to study the rarefaction effects. Finally, investigations of the engine size and the gap height on the engine performance have been conducted. The significance of the leakage in different engine size regimes was presented, and the results show that rarefaction effects affect the indicated thermal efficiency greatly with the decrease of the engine size scale.

  7. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    Science.gov (United States)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  8. Risk of acute anastomotic leakage after preoperative radiotherapy in rectal cancer

    Directory of Open Access Journals (Sweden)

    Devid Belalla

    2016-11-01

    Full Text Available Objective: To evaluate the preoperative radiotherapy and its role in anastomotic leakage. Methods: A total of 327 patients who had an anterior resection (AR in elective surgery for a rectal carcinoma were selected and operated in our clinic of surgery during the period from 2003 to 2015. Among them, 135 patients had a low anterior resection (LAR and the other 192 had an AR. This is a retrospective study. Chi-squared test was used to evaluate statistical differences and the P < 0.05 was considered statistically significant. Results: A total of 126 patients had radiotherapy before surgery, and 50 of them had a LAR. In the other 201 patients, surgery was the first treatment modality, and 83 of them had a LAR. We had an overall anastomotic leakage of 7.95% or 26% patients. Anastomotic leakage was found in 14 patients with LAR, 9 of which had radiotherapy before surgery. From the 12 patients with AR who had an anastomotic leakage, 6 of them had radiotherapy before surgery. Conclusions: Radiotherapy may affect anastomotic healing and increase the risk of leakage. This risk is higher in low anterior anastomoses where a protective stoma may be considered. A better evaluation and support for patients with preoperative radiotherapy is needed in order to diminish the concomitant risk factors as much as possible.

  9. Control room habitability assessment and in-leakage test for Korean NPP - 15510

    International Nuclear Information System (INIS)

    Song, D.S.; Lee, J.B.; Ha, S.J.; Seong, J.J.

    2015-01-01

    The assessment of control room habitability for Wolsung unit 1 was performed based on GL 2003-01 and Reg. Guide 1.197. The control room habitability program including Control Room Envelope (CRE) in-leakage test procedures, self assessment guidance, CRE boundary control program, CRE maintenance/sealing program was developed for Wolsung unit 1. The integrated CRE test was performed utilizing ASTM E741. There are two operating modes of pressurization and isolation for CRE ventilation test, and four tests were performed using each of the control room HVAC sub-trains. The control room HVAC system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The in-leakage testing was performed in accordance with CRE in-leakage test procedures. In the pressurization mode, measured unfiltered in-leakage rates for train A and train B were 0 CFM and 405 CFM respectively. In the isolation mode, measured unfiltered in-leakage rates for train A and train B were 1,739 CFM and 1,502 CFM, respectively. Maximum concentration of ammonia at the control room HVAC intake is calculated to be 0.027 g/m 3 (39 ppm), and satisfied the toxicity limit of 300 ppm. The test result shows that the measured unfiltered in-leakage is bounded by the regulatory criteria assumed in the design basis radiological analyses. (authors)

  10. Monitoring device for radioactive leakage from steam system in nuclear power plant

    International Nuclear Information System (INIS)

    Ogawa, Tateo; Sato, Kohei

    1988-01-01

    Purpose: To improve the reliability for the monitor of radio-active leakage by accumulating small quantity of radioactivities each lower than the detectable level and increasing their dose rate. Constitution: Even if the steam system radiation monitor in the nuclear power plant is disposed for the detection of in-leak radioactivity, radioactive leakage can be monitored at high reliability by increasing the small quantity of radioactivities in the drains to a detectable sensitivity range of the monitor upon detection. In view of the above, in the present invention, radioactive material catching medium is incorporated to a radio-activity monitor spool piece for accumulating small quantity of radioactivities. Specifically as the catching medium, an ion exchange resin is used for the leakage of ionic radioactive material, while an ion exchange resin increased with the mixing ratio of a cationic resin or hollow thread membrane filter is used for crud-like radioactive material leakage. These catching media are incorporated into the spool piece, thereby enabling to catch even small quantity of radioactive leakage lower than the detectable sensitivity of the radiation monitor, if should occur, in the spool piece and enabling radioactive detection for the accumulated dose rate. (Horiuchi, T.)

  11. Leakage current minimisation and power reduction techniques using sub-threshold design

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-11-01

    Full Text Available Low power IC solutions are in great demand with the rapid advancement of handheld devices, wearables, smart cards and radio frequency identification bringing a massive amount of new products to market that all have the same primary need: Powering...

  12. Leakage of CO2 from geologic storage: Role of secondaryaccumulation at shallow depth

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, K.

    2007-05-31

    Geologic storage of CO2 can be a viable technology forreducing atmospheric emissions of greenhouse gases only if it can bedemonstrated that leakage from proposed storage reservoirs and associatedhazards are small or can be mitigated. Risk assessment must evaluatepotential leakage scenarios and develop a rational, mechanisticunderstanding of CO2 behavior during leakage. Flow of CO2 may be subjectto positive feedbacks that could amplify leakage risks and hazards,placing a premium on identifying and avoiding adverse conditions andmechanisms. A scenario that is unfavorable in terms of leakage behavioris formation of a secondary CO2 accumulation at shallow depth. This paperdevelops a detailed numerical simulation model to investigate CO2discharge from a secondary accumulation, and evaluates the role ofdifferent thermodynamic and hydrogeologic conditions. Our simulationsdemonstrate self-enhancing as well as self-limiting feedbacks.Condensation of gaseous CO2, 3-phase flow of aqueous phase -- liquid CO2-- gaseous CO2, and cooling from Joule-Thomson expansion and boiling ofliquid CO2 are found to play important roles in the behavior of a CO2leakage system. We find no evidence that a subsurface accumulation of CO2at ambient temperatures could give rise to a high-energy discharge, aso-called "pneumatic eruption."

  13. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  14. Corrosion behaviour of the UO2 pellet in corrosive solutions using electrochemical Technique

    International Nuclear Information System (INIS)

    Taftanzani, A.; Sucipto; Lahagu, F.; Irianto, B.

    1996-01-01

    The UO 2 electrodes has been made from the local product of UO 2 pellets. The corrosion behaviour of the UO 2 pellets is affected by solution, by pH value and by concentration of salt solution. Investigation into corrosion behaviour of UO 2 electrodes have been carried out in saturated salt solutions using electrochemical technique. The saturated solutions have been made from salts NaCl, Na 2 CO 3 , Na 2 SO 4 and Na 3 PO 4 . The pH value have been done over range 1 pH 10 and the salt concentration (C) over range 0,001 mol/l C 1,0 mol/l, Na 2 CO 3 solution produced the lowest corrosion rates of UO 2 pellets. Those rates were relative constant in the range of pH = 4 - 8. The results indicate an influence of the Na 2 CO 3 concentrations on the corrosions on the corrosion rate, and the lowest rates occur in 0,10 mol/l Na 2 CO 3 . The lowest corrosion rate was 0.3388 mil/year in 0.10 mol/l Na 2 CO 3 by pH = 4. (author)

  15. Leakage radiation spectroscopy of organic/dielectric/metal systems

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Kawalec, Tomasz; Kostiučenko, Oksana

    2014-01-01

    side of a hemisphere fused silica prism with an index matching liquid was illuminated under normal incidence by a He-Cd 325 nm laser. Two orthogonal linear polarizations were used both parallel and perpendicular to the detection plane. Spectrally resolved leakage radiation was observed on the opposite......Leakage radiation spectroscopy of organic para-Hexaphenylene (p-6P) molecules has been performed in the spectral range 420-675 nm which overlaps with the p-6P photoluminescence band. The p-6P was deposited on 40 nm silver (Ag) films on BK7 glass, covered with SiO2 layers. The SiO2 layer thickness...

  16. Optimization of core reload design for low leakage fuel management in pressurized water reactors

    International Nuclear Information System (INIS)

    Kim, Y.J.

    1986-01-01

    A new method was developed to optimize pressurized water reactor core reload design for low leakage fuel management, a strategy recently adopted by most utilities to extend cycle length and mitigate pressurized thermal shock concerns. The method consists of a two-stage optimization process which provides the maximum cycle length for a given fresh fuel loading subject to power peaking constraints. In the first stage, a best fuel arrangement is determined at the end of cycle in the absence of burnable poisons. A direct search method is employed in conjunction with a constant power, Haling depletion. In the second stage, the core control poison requirements are determined using a linear programming technique. The solution provides the fresh fuel burnable poison loading required to meet core power peaking constraints. An accurate method of explicitly modeling burnable absorbers was developed for this purpose. The design method developed here was implemented in a currently recognized fuel licensing code, SIMULATE, that was adapted to the CYBER-205 computer. This methodology was applied to core reload design of cycles 9 and 10 for the Commonwealth Edison Zion, Unit-1 Reactor. The results showed that the optimum loading pattern for cycle 9 yielded almost a 9% increase in the cycle length while reducing core vessel fluence by 30% compared with the reference design used by Commonwealth Edison

  17. An accurate technique for the solution of the nonlinear point kinetics equations

    International Nuclear Information System (INIS)

    Picca, Paolo; Ganapol, Barry D.; Furfaro, Roberto

    2011-01-01

    A novel methodology for the solution of non-linear point kinetic (PK) equations is proposed. The technique is based on a piecewise constant approximation of PK system of ODEs and explicitly accounts for reactivity feedback effects, through an iterative cycle. High accuracy is reached by introducing a sub-mesh for the numerical evaluation of integrals involved and by correcting the source term to include the non-linear effect on a finer time scale. The use of extrapolation techniques for convergence acceleration is also explored. Results for adiabatic feedback model are reported and compared with other benchmarks in literature. The convergence trend makes the algorithm particularly attractive for applications, including in multi-point kinetics and quasi-static frameworks. (author)

  18. Measurements of Accelerator-Produced Leakage Neutron and Photon Transmission through Concrete

    International Nuclear Information System (INIS)

    2002-01-01

    Optimum shielding of the radiation from particle accelerators requires knowledge of the attenuation characteristics of the shielding material. The most common material for shielding this radiation is concrete, which can be made using various materials of different densities as aggregates. These different concrete mixes can have very different attenuation characteristics. Information about the attenuation of leakage photons and neutrons in ordinary and heavy concrete is, however, very limited. To increase our knowledge and understanding of the radiation attenuation in concrete of various compositions, we have performed measurements of the transmission of leakage radiation, photons and neutrons, from a Varian Clinac 2100C medical linear accelerator operating at maximum electron energies of 6 and 18 MeV. We have also calculated, using Monte Carlo techniques, the leakage neutron spectra and its transmission through concrete. The results of these measurements and calculations extend the information currently available for designing shielding for medical electron accelerators. Photon transmission characteristics depend more on the manufacturer of the concrete than on the atomic composition. A possible cause for this effect is a non-uniform distribution of the high-density aggregate, typically iron, in the concrete matrix. Errors in estimated transmission of photons can exceed a factor of three, depending on barrier thickness, if attenuation in high-density concrete is simply scaled from that of normal density concrete. We found that neutron transmission through the high-density concretes can be estimated most reasonably and conservatively by using the linear tenth-value layer of normal concrete if specific values of the tenth-value layer of the high-density concrete are not known. The reason for this is that the neutron transmission depends primarily on the hydrogen content of the concrete, which does not significantly depend on concrete density. Errors of factors of two

  19. A study on two phase flows of linear compressors for the prediction of refrigerant leakage

    International Nuclear Information System (INIS)

    Hwang, Il Sun; Lee, Young Lim; Oh, Won Sik; Park, Kyeong Bae

    2015-01-01

    Usage of linear compressors is on the rise due to their high efficiency. In this paper, leakage of a linear compressor has been studied through numerical analysis and experiments. First, nitrogen leakage for a stagnant piston with fixed cylinder pressure as well as for a moving piston with fixed cylinder pressure was analyzed to verify the validity of the two-phase flow analysis model. Next, refrigerant leakage of a linear compressor in operation was finally predicted through 3-dimensional unsteady, two phase flow CFD (Computational fluid dynamics). According to the research results, the numerical analyses for the fixed cylinder pressure models were in good agreement with the experimental results. The refrigerant leakage of the linear compressor in operation mainly occurred through the oil exit and the leakage became negligible after about 0.4s following operation where the leakage became lower than 2.0x10 -4 kg/s.

  20. Investigation of pool thermal hydraulics and temperature distribution in inner vessel under mechanical seal leakage

    International Nuclear Information System (INIS)

    Abraham, Juby; Velusamy, K.; Selvaraj, P.

    2015-01-01

    The primary heat sink of prototype fast breeder reactor is a sodium pool which is partitioned into cold pool and hot pool. The inner vessel which separates the cold and hot pools is having penetrations for intermediate heat exchangers. The hot sodium from hot pool leaks into the cold pool through these penetrations and to reduce the leakage, mechanical seals are provided. Leakage of hot sodium into cold pool can lead to thermal stratification in the cold pool and also will affect the temperature distribution in inner vessel. 3-D CFD studies were performed focusing these features as a function of sodium leakage. The analyses indicate that the maximum temperature difference across the IV thickness is 65°C without any leakage of sodium. The temperature difference is found to decrease with increase in leakage through the seals. It is seen that a leakage of 2.5% is acceptable. (author)

  1. Evidence for paternal leakage in hybrid periodical cicadas (Hemiptera: Magicicada spp..

    Directory of Open Access Journals (Sweden)

    Kathryn M Fontaine

    2007-09-01

    Full Text Available Mitochondrial inheritance is generally assumed to be maternal. However, there is increasing evidence of exceptions to this rule, especially in hybrid crosses. In these cases, mitochondria are also inherited paternally, so "paternal leakage" of mitochondria occurs. It is important to understand these exceptions better, since they potentially complicate or invalidate studies that make use of mitochondrial markers. We surveyed F1 offspring of experimental hybrid crosses of the 17-year periodical cicadas Magicicada septendecim, M. septendecula, and M. cassini for the presence of paternal mitochondrial markers at various times during development (1-day eggs; 3-, 6-, 9-week eggs; 16-month old 1st and 2nd instar nymphs. We found evidence of paternal leakage in both reciprocal hybrid crosses in all of these samples. The relative difficulty of detecting paternal mtDNA in the youngest eggs and ease of detecting leakage in older eggs and in nymphs suggests that paternal mitochondria proliferate as the eggs develop. Our data support recent theoretical predictions that paternal leakage may be more common than previously estimated.

  2. Evidence for paternal leakage in hybrid periodical cicadas (Hemiptera: Magicicada spp.).

    Science.gov (United States)

    Fontaine, Kathryn M; Cooley, John R; Simon, Chris

    2007-09-12

    Mitochondrial inheritance is generally assumed to be maternal. However, there is increasing evidence of exceptions to this rule, especially in hybrid crosses. In these cases, mitochondria are also inherited paternally, so "paternal leakage" of mitochondria occurs. It is important to understand these exceptions better, since they potentially complicate or invalidate studies that make use of mitochondrial markers. We surveyed F1 offspring of experimental hybrid crosses of the 17-year periodical cicadas Magicicada septendecim, M. septendecula, and M. cassini for the presence of paternal mitochondrial markers at various times during development (1-day eggs; 3-, 6-, 9-week eggs; 16-month old 1st and 2nd instar nymphs). We found evidence of paternal leakage in both reciprocal hybrid crosses in all of these samples. The relative difficulty of detecting paternal mtDNA in the youngest eggs and ease of detecting leakage in older eggs and in nymphs suggests that paternal mitochondria proliferate as the eggs develop. Our data support recent theoretical predictions that paternal leakage may be more common than previously estimated.

  3. Sistem Proteksi Arus Bocor Menggunakan Earth Leakage Circuit Breaker Berbasis Arduino

    Directory of Open Access Journals (Sweden)

    Syukriyadin Syukriyadin

    2017-02-01

    Full Text Available Touching a live part of electrical equipment either intentionally or unintentionally can cause an electric shock. The touch can occur directly or indirectly and results in the flow of electric current through the human body to the ground. This electric current is known as the leakage current and can have fatal effects on the human body such as burns, cramps, faint and death. This paper aims to design a prototype protection model of the earth leakage circuit breaker device based on Arduino (ELCBA to protect the human body from the electrical hazards. The performance of the ELCBA is investigated by detecting the earth leakage current to the grounding system (TN.  The prototype is designed and simulated by using Proteus software. Based on the response test carried out on the prototype, it can be concluded that the ELCBA can operate properly to disconnect the electric circuit if the leakage current is detected greater than or equal to 30 mA with a time delay of 15 ms and to reclose the circuit again after 5 minutes.

  4. Pipeline leakage recognition based on the projection singular value features and support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wei; Zhang, Laibin; Mingda, Wang; Jinqiu, Hu [College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, (China)

    2010-07-01

    The negative wave pressure method is one of the processes used to detect leaks on oil pipelines. The development of new leakage recognition processes is difficult because it is practically impossible to collect leakage pressure samples. The method of leakage feature extraction and the selection of the recognition model are also important in pipeline leakage detection. This study investigated a new feature extraction approach Singular Value Projection (SVP). It projects the singular value to a standard basis. A new pipeline recognition model based on the multi-class Support Vector Machines was also developed. It was found that SVP is a clear and concise recognition feature of the negative pressure wave. Field experiments proved that the model provided a high recognition accuracy rate. This approach to pipeline leakage detection based on the SVP and SVM has a high application value.

  5. Conduction mechanism of leakage current due to the traps in ZrO2 thin film

    International Nuclear Information System (INIS)

    Seo, Yohan; Lee, Sangyouk; An, Ilsin; Jeong, Heejun; Song, Chulgi

    2009-01-01

    In this work, a metal-oxide-semiconductor capacitor with zirconium oxide (ZrO 2 ) gate dielectric was fabricated by an atomic layer deposition (ALD) technique and the leakage current characteristics under negative bias were studied. From the result of current–voltage curves there are two possible conduction mechanisms to explain the leakage current in the ZrO 2 thin film. The dominant mechanism is the space charge limited conduction in the high-electric field region (1.5–5.0 MV cm −1 ) while the trap-assisted tunneling due to the existence of traps is prevailed in the low-electric field region (0.8–1.5 MV cm −1 ). Conduction caused by the trap-assisted tunneling is found from the experimental results of a weak temperature dependence of current, and the trap barrier height is obtained. The space charge limited conduction is evidenced, for different temperatures, by Child's law dependence of current density versus voltage. Child's law dependence can be explained by considering a single discrete trapping level and we can obtain the activation energy of 0.22 eV

  6. Conduction mechanism of leakage current due to the traps in ZrO2 thin film

    Science.gov (United States)

    Seo, Yohan; Lee, Sangyouk; An, Ilsin; Song, Chulgi; Jeong, Heejun

    2009-11-01

    In this work, a metal-oxide-semiconductor capacitor with zirconium oxide (ZrO2) gate dielectric was fabricated by an atomic layer deposition (ALD) technique and the leakage current characteristics under negative bias were studied. From the result of current-voltage curves there are two possible conduction mechanisms to explain the leakage current in the ZrO2 thin film. The dominant mechanism is the space charge limited conduction in the high-electric field region (1.5-5.0 MV cm-1) while the trap-assisted tunneling due to the existence of traps is prevailed in the low-electric field region (0.8-1.5 MV cm-1). Conduction caused by the trap-assisted tunneling is found from the experimental results of a weak temperature dependence of current, and the trap barrier height is obtained. The space charge limited conduction is evidenced, for different temperatures, by Child's law dependence of current density versus voltage. Child's law dependence can be explained by considering a single discrete trapping level and we can obtain the activation energy of 0.22 eV.

  7. Temperature-dependent leakage current behavior of epitaxial Bi0.5Na0.5TiO3-based thin films made by pulsed laser deposition

    Science.gov (United States)

    Hejazi, M. M.; Safari, A.

    2011-11-01

    This paper discusses the electrical conduction mechanisms in a 0.88 Bi0.5Na0.5TiO3-0.08 Bi0.5K0.5TiO3-0.04 BaTiO3 thin film in the temperature range of 200-350 K. The film was deposited on a SrRuO3/SrTiO3 substrate by pulsed laser deposition technique. At all measurement temperatures, the leakage current behavior of the film matched well with the Lampert's triangle bounded by three straight lines of different slopes. The relative location of the triangle sides varied with temperature due to its effect on the density of charge carriers and un-filled traps. At low electric fields, the ohmic conduction governed the leakage mechanism. The calculated activation energy of the trap is 0.19 eV implying the presence of shallow traps in the film. With increasing the applied field, an abrupt increase in the leakage current was observed. This was attributed to a trap-filling process by the injected carriers. At sufficiently high electric fields, the leakage current obeyed the Child's trap-free square law suggesting the space charge limited current was the dominant mechanism.

  8. High Dielectric Performance of Solution-Processed Aluminum Oxide-Boron Nitride Composite Films

    Science.gov (United States)

    Yu, Byoung-Soo; Ha, Tae-Jun

    2018-04-01

    The material compositions of oxide films have been extensively investigated in an effort to improve the electrical characteristics of dielectrics which have been utilized in various electronic devices such as field-effect transistors, and storage capacitors. Significantly, solution-based compositions have attracted considerable attention as a highly effective and practical technique to replace vacuum-based process in large-area. Here, we demonstrate solution-processed composite films consisting of aluminum oxide (Al2O3) and boron nitride (BN), which exhibit remarkable dielectric properties through the optimization process. The leakage current of the optimized Al2O3-BN thin films was decreased by a factor of 100 at 3V, compared to pristine Al2O3 thin film without a loss of the dielectric constant or degradation of the morphological roughness. The characterization by X-ray photoelectron spectroscopy measurements revealed that the incorporation of BN with an optimized concentration into the Al2O3 dielectric film reduced the density of oxygen vacancies which act as defect states, thereby improving the dielectric characteristics.

  9. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  10. Risk factors for leakage following intestinal anastomosis in dogs and cats: 115 cases (1991-2000).

    Science.gov (United States)

    Ralphs, S Christopher; Jessen, Carl R; Lipowitz, Alan J

    2003-07-01

    To identify factors associated with leakage following intestinal anastomosis in dogs and cats. Retrospective study. 90 dogs and 25 cats. Medical records of all dogs and cats that underwent intestinal resection and anastomosis between 1991 and 2000 were reviewed, and information on 27 factors was recorded. Anastomotic leakage was identified in 13 of the 90 dogs but in none of the 25 cats. Preoperative factors significantly associated with development of anastomotic leakage in dogs included preoperative peritonitis, serum albumin concentration, a left shift, and indication for surgery (dogs with intestinal foreign bodies were more likely to have leakage than dogs that underwent surgery for any other cause). Postoperative and case management factors significantly associated with development of leakage included duration of hospitalization, supplemental alimentation, whether the dog ate the day after surgery, blood product administration, and outcome (died vs survived). Discriminant analysis was performed, and dogs with 2 or more of the following factors were predicted to develop anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration dogs. Results suggest that a variety of factors may be associated with development of intestinal anastomotic leakage in dogs. In particular, dogs with 2 or more of the following risk factors are predicted to be at high risk for developing anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration < or = 2.5 g/dL.

  11. The solution of linear and nonlinear systems of Volterra functional equations using Adomian-Pade technique

    International Nuclear Information System (INIS)

    Dehghan, Mehdi; Shakourifar, Mohammad; Hamidi, Asgar

    2009-01-01

    The purpose of this study is to implement Adomian-Pade (Modified Adomian-Pade) technique, which is a combination of Adomian decomposition method (Modified Adomian decomposition method) and Pade approximation, for solving linear and nonlinear systems of Volterra functional equations. The results obtained by using Adomian-Pade (Modified Adomian-Pade) technique, are compared to those obtained by using Adomian decomposition method (Modified Adomian decomposition method) alone. The numerical results, demonstrate that ADM-PADE (MADM-PADE) technique, gives the approximate solution with faster convergence rate and higher accuracy than using the standard ADM (MADM).

  12. The utility of 5-aminolevulinic acid-mediated photodynamic diagnosis in the detection of intraoperative bile leakage.

    Science.gov (United States)

    Inoue, Yoshihiro; Imai, Yoshiro; Fujii, Kensuke; Hirokawa, Fumitoshi; Hayashi, Michihiro; Uchiyama, Kazuhisa

    2017-06-01

    The purpose of this retrospective study was to evaluate the utility of the new intraoperative bile leakage test as a preventive measure of postoperative bile leakage. 737 patients were retrospectively analyzed with respect to the management of intra- and post-operative bile leakage. Nine (8.3%) of 109 patients evaluated using conventional white light fluorescent imaging were recognized as having intra-operative bile leakage. However, performance of 5-aminolevulinic acid (5-ALA)-mediated PDD detected bile leakage intraoperatively not only in these 9 patients, but also in an additional 6 patients, such that 'red fluorescence' at the cut surface of the liver, was visualized in a total of 15 patients. The postoperative courses of most patients were uneventful, and postoperative bile leakages occurred in only one (0.9%) patient. 5-ALA fluorescence imaging may be needed to prevent postoperative bile leakage in patients at high risk for this surgical complication after hepatic resection. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Multigrid techniques for nonlinear eigenvalue probems: Solutions of a nonlinear Schroedinger eigenvalue problem in 2D and 3D

    Science.gov (United States)

    Costiner, Sorin; Taasan, Shlomo

    1994-01-01

    This paper presents multigrid (MG) techniques for nonlinear eigenvalue problems (EP) and emphasizes an MG algorithm for a nonlinear Schrodinger EP. The algorithm overcomes the mentioned difficulties combining the following techniques: an MG projection coupled with backrotations for separation of solutions and treatment of difficulties related to clusters of close and equal eigenvalues; MG subspace continuation techniques for treatment of the nonlinearity; an MG simultaneous treatment of the eigenvectors at the same time with the nonlinearity and with the global constraints. The simultaneous MG techniques reduce the large number of self consistent iterations to only a few or one MG simultaneous iteration and keep the solutions in a right neighborhood where the algorithm converges fast.

  14. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  15. Comparison of in situ polymerization and solution-dispersion techniques in the preparation of Polyimide/Montmorillonite (MMT) Nanocomposites.

    Science.gov (United States)

    Ahmad, Mansor Bin; Gharayebi, Yadollah; Salit, Mohd Sapuan; Hussein, Mohd Zobir; Shameli, Kamyar

    2011-01-01

    In this paper, Polyimide/Montmorillonite Nanocomposites (PI/MMT NCs), based on aromatic diamine (4-Aminophenyl sulfone) (APS) and aromatic dianhydride (3,3',4,4'-benzophenonetetracarboxylic dianhydride) (BTDA) were prepared using in situ polymerization and solution-dispersion techniques. The prepared PI/MMT NCs films were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), transmission electron microscopy (TEM) and thermogravimetric analysis (TGA). The XRD results showed that at the content of 1.0 wt % Organo Montmorillonite (OMMT) for two techniques and 3.0 wt % OMMT for the in situ polymerization technique, the OMMT was well-intercalated, exfoliated and dispersed into polyimide matrix. The OMMT agglomerated when its amount exceeded 10 wt % and 3.0 wt % for solution-dispersion and in situ polymerization techniques respectively. These results were confirmed by the TEM images of the prepared PI/MMT NCs. The TGA thermograms indicated that thermal stability of prepared PI/MMT NCs were increased with the increase of loading that, the effect is higher for the samples prepared by in situ polymerization technique.

  16. Safe transport of radioactive materials - Leakage testing on packages. 1. ed.

    International Nuclear Information System (INIS)

    1996-01-01

    This International Standard describes a method for relating permissible activity release rates of the radioactive contents carried within a containment system to equivalent gas leakage rates under specified test conditions. This approach is called gas leakage test methodology. However, in this International Standard it is recognized that other methodologies might be acceptable. When other methodologies are to be used, it shall be shown that the methodology demonstrates that any release of the radioactive contents will not exceed the regulatory requirements. The use of any alternative methodology shall be by agreement with the competent authority. This International Standard provides both overall and detailed guidance on the complex relationships between an equivalent gas leakage test and a permissible activity release rate. Whereas the overall guidance is universally agreed upon, the use of the detailed guidance shall be agreed upon with the competent authority during the Type B package certification process. It should be noted that, for a given package, demonstration of compliance is not limited to a single methodology. While this International Standard does not require particular gas leakage test procedures, it does present minimum requirements for any test that is to be used. It is the responsibility of the package designer or consignor to estimate or determine the maximum permissible release rate of radioactivity to the environment and to select appropriate leakage test procedures that have adequate sensitivity. This International Standard pertains specifically to Type B packages for which the regulatory containment requirements are specified explicitly

  17. Correlation between dislocations and leakage current of p-n diodes on a free-standing GaN substrate

    Science.gov (United States)

    Usami, Shigeyoshi; Ando, Yuto; Tanaka, Atsushi; Nagamatsu, Kentaro; Deki, Manato; Kushimoto, Maki; Nitta, Shugo; Honda, Yoshio; Amano, Hiroshi; Sugawara, Yoshihiro; Yao, Yong-Zhao; Ishikawa, Yukari

    2018-04-01

    Dislocations that cause a reverse leakage current in vertical p-n diodes on a GaN free-standing substrate were investigated. Under a high reverse bias, dot-like leakage spots were observed using an emission microscope. Subsequent cathodoluminescence (CL) observations revealed that the leakage spots coincided with part of the CL dark spots, indicating that some types of dislocation cause reverse leakage. When etch pits were formed on the dislocations by KOH etching, three sizes of etch pits were obtained (large, medium, and small). Among these etch pits, only the medium pits coincided with leakage spots. Additionally, transmission electron microscopy observations revealed that pure screw dislocations are present under the leakage spots. The results revealed that 1c pure screw dislocations are related to the reverse leakage in vertical p-n diodes.

  18. An integrated sensing technique for smart monitoring of water pipelines

    Science.gov (United States)

    Bernini, Romeo; Catapano, Ilaria; Soldovieri, Francesco; Crocco, Lorenzo

    2014-05-01

    Lowering the rate of water leakage from the network of underground pipes is one of the requirements that "smart" cities have to comply with. In fact, losses in the water supply infrastructure have a remarkable social, environmental and economic impact, which obviously conflicts with the expected efficiency and sustainability of a smart city. As a consequence, there is a huge interest in developing prevention policies based on state-of-art sensing techniques and possibly their integration, as well as in envisaging ad hoc technical solutions designed for the application at hand. As a contribution to this framework, in this communication we present an approach aimed to pursue a thorough non-invasive monitoring of water pipelines, with both high spatial and temporal resolution. This goal is necessary to guarantee that maintenance operations are performed timely, so to reduce the extent of the leakage and its possible side effects, and precisely, so to minimize the cost and the discomfort resulting from operating on the water supply network. The proposed approach integrates two sensing techniques that work at different spatial and temporal scales. The first one is meant to provide a continuous (in both space and time) monitoring of the pipeline and exploits a distributed optic fiber sensor based on the Brillouin scattering phenomenon. This technique provides the "low" spatial resolution information (at meter scale) needed to reveal the presence of a leak and call for interventions [1]. The second technique is based on the use of Ground Penetrating Radar (GPR) and is meant to provide detailed images of area where the damage has been detected. GPR systems equipped with suitable data processing strategies [2,3] are indeed capable of providing images of the shallow underground, where the pipes would be buried, characterized by a spatial resolution in the order of a few centimeters. This capability is crucial to address in the most proper way maintenance operations, by for

  19. Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator

    International Nuclear Information System (INIS)

    Klueter, Sebastian; Sroka-Perez, Gabriele; Schubert, Kai; Debus, Juergen

    2011-01-01

    Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a single focus design with flat-sided and tilted leaves instead of tongue-and-groove. The leakage performance of the 160 MLC was investigated on a dual energy linear accelerator Siemens ARTISTE with 6 MV and 18 MV photon energies. While the intraleaf leakage amounted to nearly the same dose for 6 and for 18 MV, a much higher interleaf leakage for 6 MV was measured. It could be reduced by simply rotating the collimator, and also by changing the voltage applied to the beam steering coils. The leakage of the 160 MLC is shown to be sensitive to beam alignment. This is of special interest for dual energy accelerators, as the two focal spots of both energies, neither in position nor in shape, do not necessarily always coincide. As a consequence of that, a higher leakage can be expected for one out of two energies for the 160 MLC. (note)

  20. Single phase cascaded H5 inverter with leakage current elimination for transformerless photovoltaic system

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Jia, X.; Lu, Z.

    2016-01-01

    Leakage current reduction is one of the important issues for the transformelress PV systems. In this paper, the transformerless single-phase cascaded H-bridge PV inverter is investigated. The common mode model for the cascaded H4 inverter is analyzed. And the reason why the conventional cascade H4...... inverter fails to reduce the leakage current is clarified. In order to solve the problem, a new cascaded H5 inverter is proposed to solve the leakage current issue. Finally, the experimental results are presented to verify the effectiveness of the proposed topology with the leakage current reduction...... for the single-phase transformerless PV systems....

  1. Detection of gaseous heavy water leakage points in CANDU 6 pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Park, T-K.; Jung, S-H.

    1996-01-01

    During reactor operation, the heavy water filled primary coolant system in a CANDU 6 Pressurized Heavy Water (PHWR) may leak through routine operations of the plant via components, mechanical joints, and during inadvertent operations etc. Early detection of leak points is therefore important to maintain plant safety and economy. There are many independent systems to monitor and recover heavy water leakage in a CANDU 6 PHWR. Methodology for early detection based on operating experience from these systems, is investigated in this paper. In addition, the four symptoms of D 2 O leakage, the associated process for clarifying and verifying the leakage, and the probable points of leakage are discussed. (author)

  2. The use of wavelet transform in oil conveying pipeline's leakage detection and location

    International Nuclear Information System (INIS)

    Han Jian; Wang Yongtao; Mu Haiwei

    2006-01-01

    This paper uses the negative press wave method basing on wavelet transform to detect the singularity point of the pressure signal of oil conveying pipeline and uses the detected singularity point to locate the leakage, this method has better effect in real applying. And this paper analyzes the merits and shortcomings of this method in detecting and locating the leakage of oil conveying pipeline, so it offers reference for studying weak leakage of oil conveying pipeline in the future. (authors)

  3. REDD+ and international leakage via food and timber markets: a CGE analysis

    NARCIS (Netherlands)

    Kuik, O.J.

    2014-01-01

    This paper studies the effect of international trade in food and timber on land use and potential carbon leakage in the context of actions to reduce emissions from deforestation and forest degradation (REDD+). First a simple analytical model of international leakage is presented that focuses on

  4. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, T. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wilke, R. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roberts, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Vignato, G. J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-03-01

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building. The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference. Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of

  5. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, T. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wilke, R. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roberts, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Vignato, G. J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-04-01

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building.The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference.Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five

  6. Application of source biasing technique for energy efficient DECODER circuit design: memory array application

    Science.gov (United States)

    Gupta, Neha; Parihar, Priyanka; Neema, Vaibhav

    2018-04-01

    Researchers have proposed many circuit techniques to reduce leakage power dissipation in memory cells. If we want to reduce the overall power in the memory system, we have to work on the input circuitry of memory architecture i.e. row and column decoder. In this research work, low leakage power with a high speed row and column decoder for memory array application is designed and four new techniques are proposed. In this work, the comparison of cluster DECODER, body bias DECODER, source bias DECODER, and source coupling DECODER are designed and analyzed for memory array application. Simulation is performed for the comparative analysis of different DECODER design parameters at 180 nm GPDK technology file using the CADENCE tool. Simulation results show that the proposed source bias DECODER circuit technique decreases the leakage current by 99.92% and static energy by 99.92% at a supply voltage of 1.2 V. The proposed circuit also improves dynamic power dissipation by 5.69%, dynamic PDP/EDP 65.03% and delay 57.25% at 1.2 V supply voltage.

  7. Radionuclide leakage monitoring during hyperthermic isolated limb perfusion for treatment of local melanoma metastasis in an extremity

    DEFF Research Database (Denmark)

    Paulsen, Ida F; Chakera, Annette Hougaard; Schmidt, Grethe

    2015-01-01

    (99m) Tc-labelled tracer infused into the isolated limb circulation. RESULTS: One hundred and sixteen of 131 procedures were completed. In 13%, a leakage of ≥10% was detected; in 6% (n = 8), the cytotoxic drug was never infused because of constant leakage; in 7% (n = 9), leakage ≥10% was measured......INTRODUCTION: The aim is to describe the importance of leakage monitoring in hyperthermic isolated limb perfusion (ILP). It is generally recommended that leakage should not exceed 10% because of risk of systemic toxicity. MATERIAL AND METHODS: Data retrieved by retrospective analysis of 131...... were observed in 14%. Three of the patients with leakage ≥10% were successfully treated in a repeated procedure. CONCLUSION: Leakage monitoring using a threshold of 10% during ILP saves the patients from systemic toxicity, however, at the expense of early termination or cancellation of ILP treatment...

  8. Dynamical scaling in polymer solutions investigated by the neutron spin echo technique

    International Nuclear Information System (INIS)

    Richter, D.; Ewen, B.

    1979-01-01

    Chain dynamics in polymer solutions was investigated by means of the recently developed neutron spin echo spectroscopy. - By this technique, it was possible for the first time to verify unambiguously the scaling predictions of the Zimm model in the case of single chain behaviour and to observe the cross over to many chain behaviour. The segmental diffusion of single chains exhibits deviations from a simple exponential law, indicating the importance of memory effects. (orig.) [de

  9. Leakage flow simulation in a specific pump model

    International Nuclear Information System (INIS)

    Dupont, P; Bayeul-Lainé, A C; Dazin, A; Bois, G; Roussette, O; Si, Q

    2014-01-01

    This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 8.06 code (RANS frozen and unsteady calculations). Comparisons between numerical and experimental results are presented and discussed for three flow rates. The performances of the diffuser obtained by numerical simulation results are compared to the performances obtained by three-hole probe indications. The comparisons show few influence of fluid leakage on global performances but a real improvement concerning the efficiency of the impeller, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up

  10. Leakage and sweet spots in triple-quantum-dot spin qubits: A molecular-orbital study

    Science.gov (United States)

    Zhang, Chengxian; Yang, Xu-Chen; Wang, Xin

    2018-04-01

    A triple-quantum-dot system can be operated as either an exchange-only qubit or a resonant-exchange qubit. While it is generally believed that the decisive advantage of the resonant-exchange qubit is the suppression of charge noise because it is operated at a sweet spot, we show that the leakage is also an important factor. Through molecular-orbital-theoretic calculations, we show that when the system is operated in the exchange-only scheme, the leakage to states with double electron occupancy in quantum dots is severe when rotations around the axis 120∘ from z ̂ is performed. While this leakage can be reduced by either shrinking the dots or separating them further, the exchange interactions are also suppressed at the same time, making the gate operations unfavorably slow. When the system is operated as a resonant-exchange qubit, the leakage is three to five orders of magnitude smaller. We have also calculated the optimal detuning point which minimizes the leakage for the resonant-exchange qubit, and have found that although it does not coincide with the double sweet spot for the charge noise, they are rather close. Our results suggest that the resonant-exchange qubit has another advantage, that leakage can be greatly suppressed compared to the exchange-only qubit, and operating at the double sweet spot point should be optimal both for reducing charge noise and suppressing leakage.

  11. Time-dependent integral transport equation kernels, leakage rates and collision rates for plane and spherical geometry

    International Nuclear Information System (INIS)

    Henderson, D.L.

    1987-01-01

    Time-dependent integral transport equation flux and current kernels for plane and spherical geometry are derived for homogeneous media. Using the multiple collision formalism, isotropic sources that are delta distributions in time are considered for four different problems. The plane geometry flux kernel is applied to a uniformly distributed source within an infinite medium and to a surface source in a semi-infinite medium. The spherical flux kernel is applied to a point source in an infinite medium and to a point source at the origin of a finite sphere. The time-dependent first-flight leakage rates corresponding to the existing steady state first-flight escape probabilities are computed by the Laplace transform technique assuming a delta distribution source in time. The case of a constant source emitting neutrons over a time interval, Δt, for a spatially uniform source is obtained for a slab and a sphere. Time-dependent first-flight leakage rates are also determined for the general two region spherical medium problem for isotropic sources with a delta distribution in time uniformly distributed throughout both the inner and outer regions. The time-dependent collision rates due to the uncollided neutrons are computed for a slab and a sphere using the time-dependent first-flight leakage rates and the time-dependent continuity equation. The case of a constant source emitting neutrons over a time interval, Δt, is also considered

  12. Estimation of Leakage Ratio Using Principal Component Analysis and Artificial Neural Network in Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    Dongwoo Jang

    2018-03-01

    Full Text Available Leaks in a water distribution network (WDS constitute losses of water supply caused by pipeline failure, operational loss, and physical factors. This has raised the need for studies on the factors affecting the leakage ratio and estimation of leakage volume in a water supply system. In this study, principal component analysis (PCA and artificial neural network (ANN were used to estimate the volume of water leakage in a WDS. For the study, six main effective parameters were selected and standardized data obtained through the Z-score method. The PCA-ANN model was devised and the leakage ratio was estimated. An accuracy assessment was performed to compare the measured leakage ratio to that of the simulated model. The results showed that the PCA-ANN method was more accurate for estimating the leakage ratio than a single ANN simulation. In addition, the estimation results differed according to the number of neurons in the ANN model’s hidden layers. In this study, an ANN with multiple hidden layers was found to be the best method for estimating the leakage ratio with 12–12 neurons. This suggested approaches to improve the accuracy of leakage ratio estimation, as well as a scientific approach toward the sustainable management of water distribution systems.

  13. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  14. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S; Ghosh, J K [Bhabha Atomic Research Centre, Bombay (India). Radiometallurgy Div.; Patel, R J [Bhabha Atomic Research Centre, Mumbai (India). Refuelling Technology Division

    1994-12-31

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs.

  15. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    International Nuclear Information System (INIS)

    Mukherjee, S.; Ghosh, J.K.; Patel, R.J.

    1994-01-01

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs

  16. Germline contamination and leakage in whole genome somatic single nucleotide variant detection.

    Science.gov (United States)

    Sendorek, Dorota H; Caloian, Cristian; Ellrott, Kyle; Bare, J Christopher; Yamaguchi, Takafumi N; Ewing, Adam D; Houlahan, Kathleen E; Norman, Thea C; Margolin, Adam A; Stuart, Joshua M; Boutros, Paul C

    2018-01-31

    The clinical sequencing of cancer genomes to personalize therapy is becoming routine across the world. However, concerns over patient re-identification from these data lead to questions about how tightly access should be controlled. It is not thought to be possible to re-identify patients from somatic variant data. However, somatic variant detection pipelines can mistakenly identify germline variants as somatic ones, a process called "germline leakage". The rate of germline leakage across different somatic variant detection pipelines is not well-understood, and it is uncertain whether or not somatic variant calls should be considered re-identifiable. To fill this gap, we quantified germline leakage across 259 sets of whole-genome somatic single nucleotide variant (SNVs) predictions made by 21 teams as part of the ICGC-TCGA DREAM Somatic Mutation Calling Challenge. The median somatic SNV prediction set contained 4325 somatic SNVs and leaked one germline polymorphism. The level of germline leakage was inversely correlated with somatic SNV prediction accuracy and positively correlated with the amount of infiltrating normal cells. The specific germline variants leaked differed by tumour and algorithm. To aid in quantitation and correction of leakage, we created a tool, called GermlineFilter, for use in public-facing somatic SNV databases. The potential for patient re-identification from leaked germline variants in somatic SNV predictions has led to divergent open data access policies, based on different assessments of the risks. Indeed, a single, well-publicized re-identification event could reshape public perceptions of the values of genomic data sharing. We find that modern somatic SNV prediction pipelines have low germline-leakage rates, which can be further reduced, especially for cloud-sharing, using pre-filtering software.

  17. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events.

    Science.gov (United States)

    Axelsson, Charles; van Sebille, Erik

    2017-11-15

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while cities actively create policies that reduce plastic leakages, more needs to be done. Nonetheless, these policies are economically, socially and environmentally cobeneficial to the city environment. While the lack of political engagement and economic concerns limit these policies, lacking social motivation and engagement is the largest limitation towards implementing policy. We recommend cities to incentivize citizen and municipal engagement with responsible usage of plastics, cleaning the environment and preparing for future extreme rainfall events. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  18. Bridge flap technique as a single-step solution to mucogingival problems: A case series

    Directory of Open Access Journals (Sweden)

    Vivek Gupta

    2011-01-01

    Full Text Available Shallow vestibule, gingival recession, inadequate width of attached gingiva (AG and aberrant frenum pull are an array of mucogingival problems for which several independent and effective surgical solutions are reported in the literature. This case series reports the effectiveness of the bridge flap technique as a single-step surgical entity for increasing the depth of the vestibule, root coverage, increasing the width of the AG and solving the problem of abnormal frenum pull. Eight patients with 18 teeth altogether having Millers class I, II or III recession along with problems of shallow vestibule, inadequate width of AG and with or without frenum pull underwent this surgical procedure and were followed-up till 9 months post-operatively. The mean root coverage obtained was 55% and the mean average gain in width of the AG was 3.5 mm. The mean percentage gain in clinical attachment level was 41%. The bridge flap technique can be an effective single-step solution for the aforementioned mucogingival problems if present simultaneously in any case, and offers considerable advantages over other mucogingival surgical techniques in terms of simplicity, limited chair-time for the patient and the operator, single surgical intervention for manifold mucogingival problems and low morbidity because of the absence of palatal donor tissue.

  19. Calibration curves for on-line leakage detection using radiotracer injection method

    Directory of Open Access Journals (Sweden)

    Ayoub Khatooni

    2017-11-01

    Full Text Available One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl detectors which were located before and after the considered position, measure emitted gamma from radioactive tracer. After calibration of radiation detectors, the amount of leakage can be calculated based on the count difference of detectors. Also, the effect of material and thickness and diameter of pipe, crystal dimension, types of fluid, activity of tracer and its type (24Na, 82Br, 131I, 99mTc, 113mIn as well as have been investigated on the detectable amount of leakage. According to the results, for example, leakage more than 0.007% in volume of the inlet fluid for iron pipe with outer diameter 4 inch and thickness of 0.5 cm, Petrol as fluid inside pipe, 3 3 inch detector and 24Na with activity of 100 mCi can be detected by this presented method.

  20. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.