WorldWideScience

Sample records for solid-phase extraction cartridges

  1. Solid phase extraction membrane

    Science.gov (United States)

    Carlson, Kurt C [Nashville, TN; Langer, Roger L [Hudson, WI

    2002-11-05

    A wet-laid, porous solid phase extraction sheet material that contains both active particles and binder and that possesses excellent wet strength is described. The binder is present in a relatively small amount while the particles are present in a relatively large amount. The sheet material is sufficiently strong and flexible so as to be pleatable so that, for example, it can be used in a cartridge device.

  2. Comparison between a commercial solid-phase extraction cartridge and a home-made silver containing charcoal column: purification of Mo-99 from I-131 and Te-121

    International Nuclear Information System (INIS)

    Dias, Carla Roberta; Teodoro, Rodrigo; Osso Junior, Joao

    2011-01-01

    Among the radioisotopes used for medical application in Nuclear Medicine, 99m Tc, readily available from the elution of 99 Mo/ 99m Tc generators, is the most used, responsible for more than eighty percent of the total applications. These generators use the 99 Mo radioisotope that is produced in nuclear reactors and IPEN imports all the 99 Mo used in Brazil, mainly from Canada (Nordion). Due to the increasing needs of the Nuclear Medicine in Brazil and the world shortage of 99 Mo observed since 2008, IPEN decided to construct a new research reactor named Brazilian Multipurpose Reactor (BMR) as well as to develop the production of 99 Mo through the route of 235 U fission using a CINTICHEM modified separation process. The 99 Mo obtained from this process contains some contaminants and need to be purified. The aim of this work is to compare the preliminary results of the purification step of the solution containing 99 Mo and the contaminants, 131 I and 121 Te in the silver containing charcoal column and a solid-phase extraction cartridge. The purification process of 99 Mo coming from fission LEU foils was performed by adsorption chromatography using a home-made activated charcoal containing silver column (AC-Ag) and a commercial solid-phase extraction cartridge (OnGuard II Ag). High yields of 99 Mo elution and high retention of 131 I were achieved in the AC-Ag column and silver cartridge but 121 Te was more retained in the cartridge than in the AC-Ag column. (author)

  3. Inductively coupled plasma mass spectrometry study of the retention behavior of arsenic species on various solid phase extraction cartridges and its application in arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Yu Chunhai; Cai Qiantao E-mail: qtcai@cawt.sui.com.sg; Guo Zhongxian; Yang Zhaoguang; Khoo, Soo Beng

    2003-07-18

    Inductively coupled plasma mass spectrometry (ICP-MS) was used to investigate the retention behavior of arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), arsenocholine (AsC), trimethylarsine oxide (TMAO) and tetramethylarsonium ion (TMAI) on various silica-based solid phase extraction (SPE) cartridges. A method for arsenic speciation is then developed on the basis of selective SPE separation of arsenic species and highly sensitive ICP-MS detection. Factors affecting the retention and elution of arsenic species were examined. Results showed that the retention of arsenic species depended on the chemical characteristics of arsenic species and the types of sorbent materials. Change of pH in the range of 2.0-9.0 did not show significant effects on the retention of DMA, AsB, AsC, TMAI and TMAO on an ethylbenzene sulfonic acid-based strong cation exchange (SCX-3) cartridge. pH also did not influence the retention of AsB, AsC, TMAI and TMAO on a mixed-mode (M-M) cartridge containing non-polar, strong cation exchange and strong anion exchange (SAX) functional groups. However, the retentions of As(V) and MMA on the SAX and the M-M cartridge changed with pH. As(V) and MMA were completely retained on the SAX cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} acetic acid (for MMA). DMA, AsB, AsC, TMAI and TMAO were completely retained on the SCX-3 cartridge and sequentially selectively eluted with 1.0 mol l{sup -1} HNO{sub 3} (for DMA). As(V), MMA, AsB, AsC, TMAI and TMAO were completely retained on the M-M cartridge. As(III) was not retained on either cartridge and remained in solution. Arsenic species in solution and those eluted from the cartridges were subsequently determined by ICP-MS. A detection limit of 8 ng l{sup -1} arsenic in water sample was obtained. This method was successfully applied to arsenic speciation in various sources of water samples (drinking water, waste water, raw water, etc.) and US

  4. A Method for Multiple Mycotoxin Analysis in Wines by Solid Phase Extraction and Multifunctional Cartridge Purification, and Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry

    Science.gov (United States)

    Tamura, Masayoshi; Takahashi, Ayumi; Uyama, Atsuo; Mochizuki, Naoki

    2012-01-01

    An analytical method using two solid phase extractions and ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed for the identification and quantification of 14 mycotoxins (patulin, deoxynivalenol, aflatoxins B1, B2, G1, G2, M1, T-2 toxin, HT-2 toxin, zearalenone, fumonisins B1, B2, B3, and ochratoxin A) in domestic and imported wines. Mycotoxins were purified with an Oasis HLB cartridge, followed by a MultiSepTM #229 Ochra. As a result, sufficient removal of the pigments and highly polar matrices from the red wines was achieved. UHPLC conditions were optimized, and 14 mycotoxins were separated in a total of 13 min. Determinations performed using this method produced high correlation coefficients for the 14 mycotoxins (R > 0.990) and recovery rates ranging from 76 to 105% with good repeatability (relative standard deviation RSD < 12%). Twenty-seven samples of domestic and imported wines were analyzed using this method. Although ochratoxin A (OTA) and fumonisins (FMs) were detected in several samples, the FM levels were less than limits of quantification (LOQs) (1 μg/L), and even the largest of the OTA levels was below the EU regulatory level (2 μg/L). These results suggest that the health risk posed to consumers from the wines available in Japan is relatively low. PMID:22822458

  5. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Multiplexed Colorimetric Solid-Phase Extraction

    Science.gov (United States)

    Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.

    2009-01-01

    Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

  7. [Determination of metformin hydrochloride, melamine and dicyandiamide in metformin hydrochloride preparations by tandem dual solid phase extraction cartridges-high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry].

    Science.gov (United States)

    Zhou, Yanfen; Wang, Fanghuan; Wang, Zelan; Zhan, Haijuan; Liu, Wanyi; Meng, Zhe

    2018-02-08

    A method for the confirmation and quantification of metformin hydrochloride and its relative substances melamine and dicyandiamide using tandem dual solid phase extraction (SPE) cartridges and high performance liquid chromatography-electrospray ionization multi-stage mass spectrometry (HPLC-ESI-MS n ) was developed. The samples were extracted with anhydrous ethanol containing 0.1% (v/v) acetic acid under ultrasound-assisted conditions. The extracts were concentrated and purified using Cleanert PCX and C18 tandem dual solid phase extraction cartridges, and eluted with 5% (v/v) ammonia methanol solution. The separation was performed on a Kromasil-C18 column (100 mm×4.6 mm, 3.5 μm) with gradient elution. The detection was performed in selected ion monitoring (SIM) mode using electrospray ionization multi-stage mass spectrometry. The external standard method was used for quantification. The extraction solvents, types of SPE cartridges and eluents were optimized by comparing the recoveries under different conditions. The results showed that the detector response of each target compound was linear in corresponding mass concentration ranges with the correlation coefficients ( r 2 ) ≥ 0.9992. The limits of detection (LODs) and the limits of quantification (LOQs) of the three analytes were 1.48-13.61 μg/kg and 5.96-45.67 μg/kg, respectively. The recoveries of the three analytes were 65.02%-118.33% spiked at low, medium and high levels. The relative standard deviations (RSDs) were no more than 13.41%. The method is reliable, easy, and has a better purification effect. The method can be applied to the routine analysis of metformin hydrochloride and its relative substances melamine and dicyandiamide in different preparations of metformin hydrochloride.

  8. Solid-phase extraction of carotenoids.

    Science.gov (United States)

    Shen, Yao; Hu, Yumin; Huang, Ke; Yin, Shi'an; Chen, Bo; Yao, Shouzhuo

    2009-07-24

    In this work, solid-phase extraction (SPE) trapping performance of lutein and beta-carotene, which were used as the model molecules of carotenoids, was investigated. The absorption, elution, and enrichment of carotenoids on SPE cartridges with four different sorbents, i.e. C(30), C(18), diol, and silica, were compared respectively with the help of frontal analysis technique. The high retentions of both lutein and beta-carotene were achieved on the C(18) and C(30) cartridges. The diol and silica cartridges only had good retention for lutein. The optimized SPE method for sample pretreatment for the carotenoids analysis was obtained after the investigation of trapping performance. The method was applied successfully to the analysis of biological sample, i.e. serum and human breast milk. The recovery, accuracy, and precision of SPE method comparing with those of traditional liquid-liquid extraction (LLE) method for the sample pretreatment for the analysis of carotenoids owned a number of advantages such as rapid, no chloroform used, and accurate versus LLE.

  9. Solid Phase Extraction and Spectrophotometric Determination of ...

    African Journals Online (AJOL)

    NJD

    2005-04-15

    Apr 15, 2005 ... to the economy and has significant industrial applications. The development of a ... Waters Solid Phase Extraction (SPE) device (the device can carry out twenty ... HPLC grade dimethyl formamide (DMF) (Fisher. Corporation ...

  10. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    International Nuclear Information System (INIS)

    Li, Jianjun; Liu, Yun; Liu, Qianping; Hui, Junfeng; Liu, Yangzi

    2017-01-01

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO 4 powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r 2  = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  11. On-cartridge derivatisation using matrix solid phase dispersion for the determination of cyclamate in foods

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jianjun, E-mail: bootan12@126.com [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Liu, Yun [College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi' an 710062 (China); Liu, Qianping [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China); Hui, Junfeng [Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, Northwest University, Xi' an 710069 (China); Liu, Yangzi [National Engineering Research Center for Miniaturized Detection Systems, Xi' an 710069 (China)

    2017-06-15

    A novel method for determination of sodium cyclamate in foods was developed. In this method, a syringe was loaded with the homogeneous mixture of the sample, KMnO{sub 4} powder and silica dispersant and used as a matrix solid phase dispersion (MSPD) reactor. As the reactor was infiltrated with small amounts of concentrated HCl, cyclamate was converted to 2-chlorocyclohexanone quickly and effectively within 5 min and determined by HPLC on a reversed-phase column using UV detection at a wavelength of 310 nm. Comparing with the traditional derivatisation in solution, the better clean-up was provided using on-cartridge derivatisation of MSPD, and much time, labor, and expense were saved. The results showed good linearity (r{sup 2} = 0.9998) over the concentration range of 1–500 mg/L. The limit of detection (LOD) and limits of quantification (LOQ) of the cyclamate were 0.3 mg/L and 1 mg/L respectively. The recoveries ranged from 91.6% to 101.3% with the relative standard deviations (RSDs) in the range of 2.5%–4.3%. - Highlights: • A novel method was developed for the determination of cyclamate in foods. • On cartridge derivatisation, using matrix solid phase dispersion, was developed. • A new derivatisation reaction for cyclamate conversion to 2-chlorocyclohexanone was developed. • The method was rapid, simple, inexpensive, effective.

  12. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium

    International Nuclear Information System (INIS)

    Nakao, Ryuji; Halldin, Christer

    2013-01-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. Methods: This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Results: Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for 11 C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Conclusion: Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma

  13. ON-SITE SOLID-PHASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are required to verify that a target analyte has been found by comparison with the mass spectra of fragrance compounds in the NIST mass spectral library. A I -L sample usually provides insufficient analyte for full scan data acquisition. This paper describes an on-site extraction method developed at the U.S. Environmental Protection Agency (USEPA)- Las Vegas Nevada - for synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for a wide array of synthetic musks. Quantification of these compounds was achieved from the full-scan data directly, without the need to acquire SIM data. The detection limits obtained with this method are an order of magnitude lower than those obtained from liquid-liquid and other solid phase extraction methods. This method is highly reproducible, and recoveries ranged from 80 to 97% in spiked sewage treatment plant effluent. The high rate of sorbent-sample mass transfer eliminated the need for a methanolic activation step, which reduced extraction time, labor, and solvent use, More samples could be extracted in the field at lower cost. After swnple extraction, the light- weight cartridges ar

  14. solid phase extraction method for selective determination

    African Journals Online (AJOL)

    FATOKI

    determination of phthalate ester plasticizers in rivers and marine water samples. Of the ... samples that receive effluent from industries that use phthalate esters. ... Keywords Phthalates, Plasticizers, Solid Phase Gas Chromatography.

  15. Novel nanoporous sorbent for solid-phase extraction in petroleum fingerprinting

    Science.gov (United States)

    Alayande, S. Oluwagbemiga; Hlengilizwe, Nyoni; Dare, E. Olugbenga; Msagati, Titus A. M.; Akinlabi, A. Kehinde; Aiyedun, P. O.

    2016-04-01

    Sample preparation is crucial in the analysis of petroleum and its derivatives. In this study, developing affordable sorbent for petroleum fingerprinting analysis using polymer waste such expanded polystyrene was explored. The potential of electrospun expanded polystyrene (EPS) as a sorbent for the solid-phase extraction (SPE) technique was investigated, and its efficiency was compared with commercial cartridges such as alumina, silica and alumina/silica hybrid commercial for petroleum fingerprinting analysis. The chromatograms showed that the packed electrospun EPS fibre demonstrated excellent properties for SPE applications relative to the hybrid cartridges.

  16. An in-line clean system for the solid-phase extraction of emerging contaminants in natural waters

    OpenAIRE

    Sodré, Fernando F.; Locatelli, Marco Antonio F.; Jardim, Wilson F.

    2010-01-01

    A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus i...

  17. Micro versus macro solid phase extraction for monitoring water contaminants: a preliminary study using trihalomethanes.

    Science.gov (United States)

    Alexandrou, Lydon D; Spencer, Michelle J S; Morrison, Paul D; Meehan, Barry J; Jones, Oliver A H

    2015-04-15

    Solid phase extraction is one of the most commonly used pre-concentration and cleanup steps in environmental science. However, traditional methods need electrically powered pumps, can use large volumes of solvent (if multiple samples are run), and require several hours to filter a sample. Additionally, if the cartridge is open to the air volatile compounds may be lost and sample integrity compromised. In contrast, micro cartridge based solid phase extraction can be completed in less than 2 min by hand, uses only microlitres of solvent and provides comparable concentration factors to established methods. It is also an enclosed system so volatile components are not lost. The sample can also be eluted directly into a detector (e.g. a mass spectrometer) if required. However, the technology is new and has not been much used for environmental analysis. In this study we compare traditional (macro) and the new micro solid phase extraction for the analysis of four common volatile trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane and tribromomethane). The results demonstrate that micro solid phase extraction is faster and cheaper than traditional methods with similar recovery rates for the target compounds. This method shows potential for further development in a range of applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Two-dimensional solid-phase extraction strategy for the selective enrichment of aminoglycosides in milk.

    Science.gov (United States)

    Shen, Aijin; Wei, Jie; Yan, Jingyu; Jin, Gaowa; Ding, Junjie; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao

    2017-03-01

    An orthogonal two-dimensional solid-phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed-phase liquid chromatography material (C 18 ) and a weak cation-exchange material (TGA) were integrated in a single solid-phase extraction cartridge. The feasibility of two-dimensional clean-up procedure that experienced two-step adsorption, two-step rinsing, and two-step elution was systematically investigated. Based on the orthogonality of reversed-phase and weak cation-exchange procedures, the two-dimensional solid-phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed-phase solid-phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation-exchange solid-phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two-dimensional clean-up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Development and Application of Solid Phase Extraction Method for ...

    African Journals Online (AJOL)

    NICO

    for the addition of organic modifier, sample load volume, conditioning solvent, washing solvent and ... Solid phase extraction, polycyclic aromatic hydrocarbons, water samples, ... such as polymeric, activated carbon or silica modified with.

  20. Determination of 8 Synthetic Food Dyes by Solid Phase Extraction ...

    African Journals Online (AJOL)

    Keywords: Synthetic colors, Food, Fruit flavored drinks, Solid phase extraction, RP-HPLC. Tropical Journal of ..... food dyes by thin-layer chromatography-fast atom bombardment ... food dyes in soft drinks containing natural pigments by.

  1. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    All rights reserved. ... 1Department of Pharmacology, 2Department of Applied Science, 3Police Forensic Science Center 10, Yala 95000, 4Natural ... Purpose: To develop a solid phase extraction (SPE) method that utilizes reverse-phase high.

  2. New practical algorithm for modelling analyte recovery in bioanalytical reversed phase and mixed-mode solid phase extraction

    NARCIS (Netherlands)

    Hendriks, G.; Uges, D. R. A.; Franke, J. P.

    2008-01-01

    Solid phase extraction (SPE) is a widely used method for sample cleanup and sample concentration in bioanalytical sample preparation. A few methods to model the retention behaviour on SPE cartridges have been described previously but they are either not applicable to ionised species or are not

  3. Solid-phase extraction versus matrix solid-phase dispersion: Application to white grapes.

    Science.gov (United States)

    Dopico-García, M S; Valentão, P; Jagodziñska, A; Klepczyñska, J; Guerra, L; Andrade, P B; Seabra, R M

    2007-11-15

    The use of matrix solid-phase dispersion (MSPD) was tested to, separately, extract phenolic compounds and organic acids from white grapes. This method was compared with a more conventional analytical method previously developed that combines solid liquid extraction (SL) to simultaneously extract phenolic compounds and organic acids followed by a solid-phase extraction (SPE) to separate the two types of compounds. Although the results were qualitatively similar for both techniques, the levels of extracted compounds were in general quite lower on using MSPD, especially for organic acids. Therefore, SL-SPE method was preferred to analyse white "Vinho Verde" grapes. Twenty samples of 10 different varieties (Alvarinho, Avesso, Asal-Branco, Batoca, Douradinha, Esganoso de Castelo Paiva, Loureiro, Pedernã, Rabigato and Trajadura) from four different locations in Minho (Portugal) were analysed in order to study the effects of variety and origin on the profile of the above mentioned compounds. Principal component analysis (PCA) was applied separately to establish the main sources of variability present in the data sets for phenolic compounds, organic acids and for the global data. PCA of phenolic compounds accounted for the highest variability (77.9%) with two PCs, enabling characterization of the varieties of samples according to their higher content in flavonol derivatives or epicatechin. Additionally, a strong effect of sample origin was observed. Stepwise linear discriminant analysis (SLDA) was used for differentiation of grapes according to the origin and variety, resulting in a correct classification of 100 and 70%, respectively.

  4. Solid-Phase Extraction Combined with High Performance Liquid ...

    African Journals Online (AJOL)

    Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen. Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a ...

  5. Comparison of solvent extraction and solid-phase extraction for the determination of polychlorinated biphenyls in transformer oil.

    Science.gov (United States)

    Mahindrakar, A N; Chandra, S; Shinde, L P

    2014-01-01

    Solid-phase extraction (SPE) of nine polychlorinated biphenyls (PCBs) from transformer oil samples was evaluated using octadecyl (CI8)-bonded porous silica. The efficiency of SPE of these PCBs was compared with those obtained by solvent extraction with DMSO and hexane. Average recoveries exceeding 95% for these PCBs were obtained via the SPE method using small cartridges containing 100mg of 40 pm CI8-bonded porous silica. The average recovery by solvent extraction with DMSO and hexane exceeded 83%. It was concluded that the recoveries and precision for the solvent extraction of PCBs were poorer than those for the SPE. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Automated solid-phase extraction of herbicides from water for gas chromatographic-mass spectrometric analysis

    Science.gov (United States)

    Meyer, M.T.; Mills, M.S.; Thurman, E.M.

    1993-01-01

    An automated solid-phase extraction (SPE) method was developed for the pre-concentration of chloroacetanilide and triazine herbicides, and two triazine metabolites from 100-ml water samples. Breakthrough experiments for the C18 SPE cartridge show that the two triazine metabolites are not fully retained and that increasing flow-rate decreases their retention. Standard curve r2 values of 0.998-1.000 for each compound were consistently obtained and a quantitation level of 0.05 ??g/l was achieved for each compound tested. More than 10,000 surface and ground water samples have been analyzed by this method.

  7. Determination of phenols in landfill leachate-contaminated groundwaters by solid-phase extraction

    DEFF Research Database (Denmark)

    Ask Reitzel, Lotte; Ledin, Anna

    2002-01-01

    A solid-phase extraction method for phenols in landfill leachates was developed and optimized in order to solve the expected and observed problems associated with an anaerobic matrix containing high concentrations of salts and organic matter. Isolute ENV1 cartridges exhibited the best retention...... be identified in leachates from three Danish landfills, ranging in concentration from 0.01 to 29 mg/ L, which is at the lower end of the concentration range usually found for phenols in landfill leachates (sub-mg/L to mg/L).  2002 Elsevier Science B.V. All rights reserved....

  8. Monitoring of chloropesticide methoxychlor preconcentration from waste water using hplc - solid phase extraction (abstract)

    International Nuclear Information System (INIS)

    Butt, S.B.; Saqlin, M.; Riaz, M.

    2011-01-01

    The method involves preconcentration of methoxychlor by solid phase extraction (SPE) with 1 mL silica based C-18 and 3 mL polymer based C-18 cartridge and then quantification by high performance liquid chromatography with UV detector (HPLC-UV). Optimization of HPLC parameters was done by determining max of methoxychlor on a double beam UV/Visible spectrophotometer, flow rate of mobile phase on reversed phase columns. Lowest detection limit for methoxychlor dissolved in water and methanol was 0.2ppm and 0.1ppm respectively. For solid phase extraction recovery studies and effect of different parameters such as initial concentration of analyte 0.01 to 0.05 ppm, loading rate 1 and 2mL/min, nature of desorbing solvent (methanol, ethyl acetate and acetonitrile) were investigated. Periodic self degradation of methoxychlor, and reusing potential of both SPE materials was also explored. Lower initial concentrations and slower loading rate of methoxychlor solutions gave improved recoveries. Recoveries were in the range of 80 to 90% for new SPE cartridge and reduced to 35 to 57% for once used silica based C-18 tubes. It was around 73 % for HLB C18 on their second use, and decreased on their repeated reuse. Lastly recoveries for stimulant and real waste water samples were determined to be 77 and 60% respectively. (author)

  9. Solid phase micro-extraction in environmental atmosphere

    International Nuclear Information System (INIS)

    Tao Ping; Wei Lifan; Tan Yun

    2002-01-01

    Solid phase micro-extraction (SPME) is an advanced technique of sample pretreatment in environmental atmosphere analysis, i.e., a sampling method of extracting volatile organic compounds from environmental gas. According to the primary survey on the theory and application of SPME, a suitable extraction tip, i.e., a coated fused silica fiber, is selected to construct a SPME apparatus. This SPME apparatus is used to extract volatile organic compounds from environmental atmosphere and a qualitative detection is conducted in gas chromatography-mass spectrometer system. Good experimental results are obtained

  10. Separation and Purification of Sulforaphane from Broccoli by Solid Phase Extraction

    Directory of Open Access Journals (Sweden)

    Kyung Ho Row

    2011-03-01

    Full Text Available A simple solid-phase extraction (SPE method for the determination of sulforaphane in broccoli has been developed. The optimal conditions were found to be use of a silica SPE cartridge, and ethyl acetate and dichloromethane as washing and eluting solvents, respectively, which could eliminate interferences originating from the broccoli matrix. The extracts were sufficiently clean to be directly injected into high-performance liquid chromatography (HPLC for further chromatographic analysis. Good linearity was obtained from 0.05 to 200 μg/mL (r = 0.998 for sulforaphane with the relative standard deviations less than 3.6%. The mean recoveries of sulforaphane from broccoli were more than 90.8% and the detection limit (S/N = 3:1 was 0.02 μg/mL. The SPE method provides a higher yield of sulforaphane from crude extracts compared to conventional liquid-liquid extraction.

  11. Chromatography, solid-phase extraction, and capillary electrochromatography with MIPs.

    Science.gov (United States)

    Tóth, Blanka; Horvai, George

    2012-01-01

    Most analytical applications of molecularly imprinted polymers are based on their selective adsorption properties towards the template or its analogs. In chromatography, solid phase extraction and electrochromatography this adsorption is a dynamic process. The dynamic process combined with the nonlinear adsorption isotherm of the polymers and other factors results in complications which have limited the success of imprinted polymers. This chapter explains these problems and shows many examples of successful applications overcoming or avoiding the problems.

  12. Simultaneous quantification of dissolved organic carbon fractions and copper complexation using solid-phase extraction

    International Nuclear Information System (INIS)

    McElmurry, Shawn P.; Long, David T.; Voice, Thomas C.

    2010-01-01

    Trace metal cycling in natural waters is highly influenced by the amount and type of dissolved organic C (DOC). Although determining individual species of DOC is unrealistic, there has been success in classifying DOC by determining operationally defined fractions. However, current fractionation schemes do not allow for the simultaneous quantification of associated trace metals. Using operational classifications, a scheme was developed to fractionate DOC based on a set of seven solid-phase extraction (SPE) cartridges. The cartridges isolated fractions based on a range of specific mechanisms thought to be responsible for DOC aggregation in solution, as well as molecular weight. The method was evaluated to determine if it can identify differences in DOC characteristics, including differences in Cu-DOC complexation. Results are that: (1) cartridge blanks were low for both DOC and Cu, (2) differences are observed in the distribution of DOC amongst the fractions from various sources that are consistent with what is known about the DOC materials and the mechanisms operative for each cartridge, (3) when present as a free cation, Cu was not retained by non-cationic cartridges allowing the method to be used to assess Cu binding, (4) the capability of the method to provide quantitative assessment of Cu-DOC complexation was demonstrated for a variety of DOC standards, (5) Cu was found to preferentially bind with high molecular weight fractions of DOC, and (6) estimated partitioning coefficients and conditional binding constants for Cu were similar to those reported elsewhere. The method developed describes DOC characteristics based on specific bonding mechanisms (hydrogen, donor-acceptor, London dispersion, and ionic bonding) while simultaneously quantifying Cu-DOC complexation. The method provides researchers a means of describing not only the extent of DOC complexation but also how that complex will be behave in natural waters.

  13. Tandem Solid Phase Extraction for the Determination of Pharmaceuticals in Wastewater

    International Nuclear Information System (INIS)

    Licaberth Ismail; Rozita Osman; Norashikin Saim

    2013-01-01

    In this study, a simple and rapid tandem solid phase extraction (SPE) was developed for the analysis of seven pharmaceuticals (acetaminophen, caffeine, carbamazepine, diclofenac, naproxen, ibuprofen and metaprolol) in wastewater sample. The novel aspect of coupling SPE cartridge in tandem is the ability to simplify the SPE procedure (sample introduction step) as no single sorbent was able to retain and concentrate all selected compounds since these compounds are of different physicochemical properties. A tandem SPE cartridges using Oasis HLB and octadecyl bonded silica (C 18 ) was found to be efficient with the advantages of minimizing sample volume and reducing analysis time. Using this approach, carbamazepine, diclofenac, naproxen and metaprolol were trapped in the Oasis HLB while acetaminophen, caffeine and ibuprofen were trapped in the second cartridge (C 18 ). The instrumental limits of detection (LOD) ranged from 0.01 to 0.04 μg/ L and satisfactory recoveries were obtained between 76 % to 104 %. The calibration curves were linear from 0.1 to 5.0 μg/ mL, with correlation coefficients (R 2 ) in the range of 0.995 to 0.999. The developed method was applied to the analysis of pharmaceuticals in wastewater samples. The amount of pharmaceuticals detected in wastewater samples varied from 0.4 to 24.5 mg/ L. (author)

  14. Basic hydrolysis of 1, 3, 4, 6-tetra-O-acetyl-2-[18F] fluoro-D-glucose on solid phase extraction

    International Nuclear Information System (INIS)

    Zhang Jinming; Tian Jiahe; He Yijie; Huan Dingcai; Liu Boli

    2003-01-01

    A new base hydrolysis method are used for 1, 3, 4, 6-tetra-O-acetyl-2-[ 18 F] fluoro-D-glucose on solid phase extraction. The labeled intermediate is trapped on an active C-18 solid phase extraction cartridge, and hydrolyzed in cartridge with 1 mL 2 mol/L NaOH at room temperature. The results show that there are over 99% of the labeled intermediate being turned into 18 F-FDG within 2 min. It is easy to get 18 F-FDG after neutralized with phosphate buffer, purified by C-18 and Alumina cartridge. The basic hydrolysis on solid extraction is a simple method for preparation of 18 F-FDG

  15. Determination of nanomolar chromate in drinking water with solid phase extraction and a portable spectrophotometer.

    Science.gov (United States)

    Ma, Jian; Yang, Bo; Byrne, Robert H

    2012-06-15

    Determination of chromate at low concentration levels in drinking water is an important analytical objective for both human health and environmental science. Here we report the use of solid phase extraction (SPE) in combination with a custom-made portable light-emitting diode (LED) spectrophotometer to achieve detection of chromate in the field at nanomolar levels. The measurement chemistry is based on a highly selective reaction between 1,5-diphenylcarbazide (DPC) and chromate under acidic conditions. The Cr-DPC complex formed in the reaction can be extracted on a commercial C18 SPE cartridge. Concentrated Cr-DPC is subsequently eluted with methanol and detected by spectrophotometry. Optimization of analytical conditions involved investigation of reagent compositions and concentrations, eluent type, flow rate (sample loading), sample volume, and stability of the SPE cartridge. Under optimized conditions, detection limits are on the order of 3 nM. Only 50 mL of sample is required for an analysis, and total analysis time is around 10 min. The targeted analytical range of 0-500 nM can be easily extended by changing the sample volume. Compared to previous SPE-based spectrophotometric methods, this analytical procedure offers the benefits of improved sensitivity, reduced sample consumption, shorter analysis time, greater operational convenience, and lower cost. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Using a new ligand for solid phase extraction of mercury

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Majid, E-mail: m-soleimani@hotmail.com [Department of Chemistry, Faculty of Sciences, Imam Khomeini International University (IKIU), Qazvin (Iran, Islamic Republic of); Mahmodi, Mohamad Saleh [Department of Chemistry, Faculty of Sciences, Imam Khomeini International University (IKIU), Qazvin (Iran, Islamic Republic of); Morsali, Ali [Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Khani, Azam; Afshar, Majid Ghahraman [Department of Chemistry, Faculty of Sciences, Imam Khomeini International University (IKIU), Qazvin (Iran, Islamic Republic of)

    2011-05-15

    The octadecyl silica cartridge as a sorbent and 4-bpdb (1,4-bis(4-pyridyl)-2,3-diaza-1,3-butadiene) as a ligand is a simple, rapid and reliable method for extracting and preconcentrating of Hg(II) in real samples prior to cold vapor atomic absorption spectrometry. Sample solutions were passed through a column at pH 4.5 then retained mercury ions on the column were eluted with minimal amount of 0.01 M nitric acid with 3 mL min{sup -1} flow rate. The effect of pH, type of buffer, flow rate of sample and eluent, type and volume of the eluent were investigated and optimized. At optimum effective parameters, concentration factor and detection limit were achieved 128 and 1.87 ng L{sup -1}, respectively.

  17. Using a new ligand for solid phase extraction of mercury

    International Nuclear Information System (INIS)

    Soleimani, Majid; Mahmodi, Mohamad Saleh; Morsali, Ali; Khani, Azam; Afshar, Majid Ghahraman

    2011-01-01

    The octadecyl silica cartridge as a sorbent and 4-bpdb (1,4-bis(4-pyridyl)-2,3-diaza-1,3-butadiene) as a ligand is a simple, rapid and reliable method for extracting and preconcentrating of Hg(II) in real samples prior to cold vapor atomic absorption spectrometry. Sample solutions were passed through a column at pH 4.5 then retained mercury ions on the column were eluted with minimal amount of 0.01 M nitric acid with 3 mL min -1 flow rate. The effect of pH, type of buffer, flow rate of sample and eluent, type and volume of the eluent were investigated and optimized. At optimum effective parameters, concentration factor and detection limit were achieved 128 and 1.87 ng L -1 , respectively.

  18. IN SITU SOLID-PHASE EXTRACTION AND ANALYSIS OF ...

    Science.gov (United States)

    Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of 1-L samples. A 1-L sample, however, usually provides too little analyte for full-scan data acquisition.We have developed an on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-s

  19. A fast, simple and green method for the extraction of carbamate pesticides from rice by microwave assisted steam extraction coupled with solid phase extraction.

    Science.gov (United States)

    Song, Weitao; Zhang, Yiqun; Li, Guijie; Chen, Haiyan; Wang, Hui; Zhao, Qi; He, Dong; Zhao, Chun; Ding, Lan

    2014-01-15

    This paper presented a fast, simple and green sample pretreatment method for the extraction of 8 carbamate pesticides in rice. The carbamate pesticides were extracted by microwave assisted water steam extraction method, and the extract obtained was immediately applied on a C18 solid phase extraction cartridge for clean-up and concentration. The eluate containing target compounds was finally analysed by high performance liquid chromatography with mass spectrometry. The parameters affecting extraction efficiency were investigated and optimised. The limits of detection ranging from 1.1 to 4.2ngg(-1) were obtained. The recoveries of 8 carbamate pesticides ranged from 66% to 117% at three spiked levels, and the inter- and intra-day relative standard deviation values were less than 9.1%. Compared with traditional methods, the proposed method cost less extraction time and organic solvent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Analysis of trace dicyandiamide in stream water using solid phase extraction and liquid chromatography UV spectrometry.

    Science.gov (United States)

    Qiu, Huidong; Sun, Dongdi; Gunatilake, Sameera R; She, Jinyan; Mlsna, Todd E

    2015-09-01

    An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0mL/min, and dicyandiamide was eluted with 20mL of a methanol/acetonitrile mixture (V/V=2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography-ultraviolet spectroscopy (HPLC-UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC(®)-Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50mm×2.1mm, 3.5μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R(2)>0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n=3) were below 6.1% with a detection limit of 5.0ng/mL for stream water samples. Copyright © 2015. Published by Elsevier B.V.

  1. Molecularly imprinted solid-phase extraction of glutathione from urine samples

    International Nuclear Information System (INIS)

    Song, Renyuan; Hu, Xiaoling; Guan, Ping; Li, Ji; Zhao, Na; Wang, Qiaoli

    2014-01-01

    Molecularly imprinted polymer (MIP) particles for glutathione were synthesized through iniferter-controlled living radical precipitation polymerization (IRPP) under ultraviolet radiation at ambient temperature. Static adsorption, solid-phase extraction, and high-performance liquid chromatography were carried out to evaluate the adsorption properties and selective recognition characteristics of the polymers for glutathione and its structural analogs. The obtained IRPP-MIP particles exhibited a regularly spherical shape, rapid binding kinetics, high imprinting factor, and high selectivity compared with the MIP particles prepared using traditional free-radical precipitation polymerization. The selective separation and enrichment of glutathione from the mixture of glycyl-glycine and glutathione disulfide could be achieved on the IRPP-MIP cartridge. The recoveries of glutathione, glycyl-glycine, and glutathione disulfide were 95.6% ± 3.65%, 29.5% ± 1.26%, and 49.9% ± 1.71%, respectively. The detection limit (S/N = 3) of glutathione was 0.5 mg·L −1 . The relative standard deviations (RSDs) for 10 replicate detections of 50 mg·L −1 of glutathione were 5.76%, and the linear range of the calibration curve was 0.5 mg·L −1 to 200 mg·L −1 under optimized conditions. The proposed approach was successfully applied to determine glutathione in spiked human urine samples with recoveries of 90.24% to 96.20% and RSDs of 0.48% to 5.67%. - Highlights: • Imprinted polymer particles were prepared by IRPP at ambient temperature. • High imprinting factor, high selectivity, and rapid binding kinetics were achieved. • Selective solid-phase extraction of glutathione from human urine samples

  2. Determination of colloidal and dissolved silver in water samples using colorimetric solid-phase extraction.

    Science.gov (United States)

    Hill, April A; Lipert, Robert J; Porter, Marc D

    2010-03-15

    The increase in bacterial resistance to antibiotics has led to resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). However, growing concerns about the possible toxicity of colloidal silver to bacteria, aquatic organisms and humans have led to recently issued regulations by the US EPA and FDA regarding the usage of silver. As part of an ongoing project, we have developed a rapid, simple method for determining total silver, both ionic (silver(I)) and colloidal, in 0.1-1mg/L aqueous samples, which spans the ISS potable water target of 0.3-0.5mg/L (total silver) and meets the US EPA limit of 0.1mg/L in drinking water. The method is based on colorimetric solid-phase extraction (C-SPE) and involves the extraction of silver(I) from water samples by passage through a solid-phase membrane impregnated with the colorimetric reagent DMABR (5-[4-(dimethylamino)benzylidene]rhodanine). Silver(I) exhaustively reacts with impregnated DMABR to form a colored compound, which is quantified using a handheld diffuse reflectance spectrophotometer. Total silver is determined by first passing the sample through a cartridge containing Oxone, which exhaustively oxidizes colloidal silver to dissolved silver(I). The method, which takes less than 2 min to complete and requires only approximately 1 mL of sample, has been validated through a series of tests, including a comparison with the ICP-MS analysis of a water sample from ISS that contained both silver(I) and colloidal silver. Potential earth-bound applications are also briefly discussed. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  3. Bioanalysis of tobramycin for therapeutic drug monitoring by solid-phase extraction and capillary zone electrophoresis.

    Science.gov (United States)

    Fonge, Humphrey; Kaale, Eliangiringa; Govaerts, Cindy; Desmet, Koenraad; Van Schepdael, Ann; Hoogmartens, Jos

    2004-10-25

    A method based on solid-phase extraction (SPE) and capillary zone electrophoresis (CZE) for the analysis of tobramycin in human serum is presented. An off-line SPE employing a carboxypropyl bonded phase (CBA) cartridge was used for the extraction of tobramycin from human serum. Adsorbed tobramycin was eluted from the CBA cartridge using a mixture of NH(3) (25%, w/v)-methanol (30:70, v/v). After evaporation, the analyte was reconstituted and derivatized with o-phthaldialdehyde (OPA)/3-mercaptopropionic acid (MPA). The resulting tobramycin-OPA/MPA derivative was purified, and then identified by mass spectrometry. The tobramycin-OPA/MPA derivative was then analysed by CZE with a background electrolyte (BGE) comprising of 30 mM sodium tetraborate pH 10.0-acetonitrile (ACN) (80:20, v/v) with ultraviolet detection at 230 nm. A linear response was observed in the range of 0.3-30 microg/ml with r(2) = 0.992. The sensitivity of the method was determined by its limit of quantitation (LOQ) and limit of detection (LOD) of 0.3 microg/ml and 0.1 microg/ml, respectively. SPE recovery ranged from 68 to 79% at the trough levels to 98% at the peak levels found in serum. Furosemide has been added as internal standard (IS) to improve precision. For the therapeutic range of tobramycin in serum (2-10 microg/ml) the relative standard deviation (R.S.D.) was less than 11% for the entire SPE/CE process. The method demonstrated excellent selectivity as shown by the lack of interference from a total of 20 drugs investigated. The method was then used in therapeutic drug monitoring of patients receiving the drug.

  4. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  5. MOLECULARLY IMPRINTED SOLID PHASE EXTRACTION FOR TRACE ANALYSIS OF DIAZINON IN DRINKING WATER

    Directory of Open Access Journals (Sweden)

    M. Rahiminejad ، S. J. Shahtaheri ، M. R. Ganjali ، A. Rahimi Forushani ، F. Golbabaei

    2009-04-01

    Full Text Available Amongst organophosphate pesticides, the one most widely used and common environmental contaminant is diazinon; thus methods for its trace analysis in environmental samples must be developed. Use of diazinon imprinted polymers such as sorbents in solid phase extraction, is a prominent and novel application area of molecular imprinted polymers. For diazinon extraction, high performance liquid chromatography analysis was demonstrated in this study. During optimization of the molecular imprinted solid phase extraction procedure for efficient solid phase extraction of diazinon, Plackett-Burman design was conducted. Eight experimental factors with critical influence on molecular imprinted solid phase extraction performance were selected, and 12 different experimental runs based on Plackett-Burman design were carried out. The applicability of diazinon imprinted polymers as the sorbent in solid phase extraction, presented obtained good recoveries of diazinon from LC-grade water. An increase in pH caused an increase in the recovery on molecular imprinted solid phase extraction. From these results, the optimal molecular imprinted solid phase extraction procedure was as follows: solid phase extraction packing with 100 mg diazinon imprinted polymers; conditioning with 5 mL of methanol and 6 mL of LC-grade water; sample loading containing diazinon (pH=10; washing with 1 mL of LC-grade water, 1 mL LC- grade water containing 30% acetonitrile and 0.5 mL of acetonitrile, respectively; eluting with 1 mL of methanol containing 2% acetic acid. The percentage recoveries obtained by the optimized molecular imprinted solid phase extraction were more than 90% with drinking water spiked at different trace levels of diazinon. Generally speaking, the molecular imprinted solid phase extraction procedure and subsequent high performance liquid chromatography analysis can be a relatively fast and proper approach for qualitative and quantitative analysis of diazinon in

  6. Solid-phase extraction clean-up of ciguatoxin-contaminated coral fish extracts for use in the mouse bioassay.

    Science.gov (United States)

    Wong, Chun Kwan; Hung, Patricia; Lee, Kellie L H; Kam, Kai Man

    2009-02-01

    Florisil solid-phase extraction (SPE) cartridges were used for purifying ciguatoxin (CTX)-contaminated coral fish extracts, with the aim of removing extracted lipid but retaining optimal level of CTXs in the purified fractions. The CTX-containing fraction (target fraction) in fish ether extract was isolated and purified by eluting through a commercially available Florisil cartridge with hexane-acetone-methanol solvent mixtures of increasing polarity (hexane-acetone (4:1, v/v) < acetone-methanol (7:3, v/v) < 100% methanol). Application of Florisil SPE using acetone-methanol (7:3, v/v) condition facilitated the separation of 4.2 +/- 0.4 mg (mean +/- standard error of the mean (SEM)) of purified target fraction from 20 mg ether extract with good retention of CTXs. The mouse bioassay was used to demonstrate that the average CTX recovery of the target fraction from CTX-spiked samples was 75.8% +/- 3.3%, which was significantly increased by 96.7% +/- 15% when compared with CTX recovery from ether extracts (44.8% +/- 5.2%) without performing SPE purification. Over 70% of non-target lipids were removed in which no CTX toxicity was found. Moreover, the target fractions of both CTX-spiked and naturally CTX-contaminated samples gave more prominent toxic responses of hypothermia and/or induced more rapid death of the mice. The use of acetone-methanol (7:3, v/v) condition in the elution could significantly improve overall recovery of CTXs, while minimizing the possible interferences of lipid matrix from co-extractants on mice.

  7. Novel chromatographic separation and carbon solid-phase extraction of acetanilide herbicide degradation products.

    Science.gov (United States)

    Shoemaker, Jody A

    2002-01-01

    One acetamide and 5 acetanilide herbicides are currently registered for use in the United States. Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of these acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. Alachlor ESA and other acetanilide degradation products are listed on the U.S. Environmental Protection Agency's (EPA) 1998 Drinking Water Contaminant Candidate List. Consequently, EPA is interested in obtaining national occurrence data for these contaminants in drinking water. EPA currently does not have a method for determining these acetanilide degradation products in drinking water; therefore, a research method is being developed using liquid chromatography/negative ion electrospray/mass spectrometry with solid-phase extraction (SPE). A novel chromatographic separation of the acetochlor/alachlor ESA and OA structural isomers was developed which uses an ammonium acetate-methanol gradient combined with heating the analytical column to 70 degrees C. Twelve acetanilide degradates were extracted by SPE from 100 mL water samples using carbon cartridges with mean recoveries >90% and relative standard deviations < or =16%.

  8. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    Science.gov (United States)

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  9. Solid-phase extraction of plutonium in various oxidation states from simulated groundwater using N-benzoylphenylhydroxylamine

    International Nuclear Information System (INIS)

    Perevalov, S.A.; Malofeeva, G.I.; Kuzovkina, E.V.; Spivakov, B.Ya.

    2013-01-01

    Solid-phase extraction of plutonium in different individual and mixed oxidation states from simulated groundwater (pH 8.5) was studied. The extraction of plutonium species was carried out in a dynamic mode using DIAPAK C16 cartridges modified by N-benzoylphenylhydroxylamine (BPHA). It was shown that the extent of recovery depends on the oxidation state of plutonium. The extraction of Pu(IV) was at the level of 98-99% regardless of the volume and flow-rate of the sample solution. Pu(V) was extracted by 90-95% and 75-80% from 10- and 100-mL aliquots of the samples, respectively, whereas the extraction of Pu(VI) did not exceed 45-50%. An equimolar mixture of Pu(IV), Pu(V), and Pu(VI) was extracted by 74%. The distribution coefficients (K d ) and kinetic exchange capacities (S) of plutonium in various oxidation states were measured. It was found that during the sorption process, Pu(V) was reduced to Pu(IV) by 80-90% after an hour-long contact with the solid phase. Pu(VI) is reduced to Pu(V) by 34% and to Pu(IV) by 55%. In the case of mixed-valent solution of plutonium, only Pu(V) and Pu(IV) were found in the effluents. (author)

  10. Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

    Science.gov (United States)

    Wang, Zuwei; Vaksman, Zalman; Boyd, Jason; Putcha, Lakshmi

    2007-01-01

    Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS

  11. Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bassarab, P; Williams, D; Dean, J R; Ludkin, E; Perry, J J

    2011-02-04

    A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Comparison of solid phase extraction, saponification and gel permeation chromatography for the clean-up of microwave-assisted biological extracts in the analysis of polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Navarro, P; Cortazar, E; Bartolomé, L; Deusto, M; Raposo, J C; Zuloaga, O; Arana, G; Etxebarria, N

    2006-09-22

    The feasibility of different clean-up procedures was studied for the determination of polycyclic aromatic hydrocarbons (PAHs) in biota samples such as oysters, mussels and fish liver. In this sense, once the samples were extracted--essentially with acetone and in a microwave system--and before they could be analysed by gas chromatography-mass spectrometry (GC-MS), three different approaches were studied for the clean-up step: solid phase extraction (SPE), microwave-assisted saponification (MAS) and gel permeation chromatography (GPC). The main aim of this work was to maximise the recoveries of PAHs and to minimise the presence of interfering compounds in the last extract. In the case of SPE, Florisil cartridges of 1, 2 and 5 g, and silica cartridges of 5 g were studied. In that case, and with oysters and mussels, microwave-assisted extraction and 5 g Florisil cartridges provided good results. In addition, the concentrations obtained for Standard Reference Material (SRM) NIST 2977 (mussel tissue) were in good agreement with the certified values. In the case of microwave-assisted saponification, the extracts were not as clean as those obtained with 5 g Florisil and this fact lead to overestimate the concentration of the heaviest PAHs. Finally, the cleanest extracts were obtained by GPC. The method was successfully applied to mussels, oysters and hake liver, and the results obtained for NIST 2977 (mussel tissue) were within the confidence interval of the certified reference material for most of the certified analytes.

  13. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.; Afsarimanesh, Nasrin; Xie, Li; Nag, Anindya; Al-Bahadly, I. H.; Yu, P. L.; Kosel, Jü rgen

    2016-01-01

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid

  14. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  15. Hypercrosslinked particles for the extraction of sweeteners using dispersive solid-phase extraction from environmental samples.

    Science.gov (United States)

    Lakade, Sameer S; Zhou, Qing; Li, Aimin; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa M

    2018-04-01

    This work presents a new extraction material, namely, Q-100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid-phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q-100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid-phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q-100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid-phase extraction using Q-100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. ZnO nanorod array solid phase micro-extraction fiber coating: fabrication and extraction capability

    International Nuclear Information System (INIS)

    Wang Dan; Zhang Zhuomin; Li Tiemei; Zhang Lan; Chen Guonan; Luo Lin

    2009-01-01

    In this paper, a ZnO nanorod array has been introduced as a coating to the headspace solid phase micro-extraction (HSSPME) field. The coating shows good extraction capability for volatile organic compounds (VOCs) by use of BTEX as a standard and can be considered suitable for sampling trace and small molecular VOC targets. In comparison with the randomly oriented ZnO nanorod HSSPME coating, ZnO nanorod array HSSPME fiber coating shows better extraction capability, which is attributed to the nanorod array structure of the coating. Also, this novel nanorod array coating shows good extraction selectivity to 1-propanethiol.

  17. Combining cationic and anionic mixed-mode sorbents in a single cartridge to extract basic and acidic pharmaceuticals simultaneously from environmental waters.

    Science.gov (United States)

    Salas, Daniela; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa Maria

    2018-01-01

    The aim of the present study is to broaden the applications of mixed-mode ion-exchange solid-phase extraction sorbents to extract both basic and acidic compounds simultaneously by combining the sorbents in a single cartridge and developing a simplified extraction procedure. Four different cartridges containing negative and positive charges in the same configuration were evaluated and compared to extract a group of basic, neutral, and acidic pharmaceuticals selected as model compounds. After a thorough optimization of the extraction conditions, the four different cartridges showed to be capable of retaining basic and acidic pharmaceuticals simultaneously through ionic interactions, allowing the introduction of a washing step with 15 mL methanol to eliminate interferences retained by hydrophobic interactions. Using the best combined cartridge, a method was developed, validated, and further applied to environmental waters to demonstrate that the method is promising for the extraction of basic and acidic compounds from very complex samples.

  18. Determination of ethylenediaminetetraacetic acid in sea water by solid-phase extraction and high-performance liquid chromatography.

    Science.gov (United States)

    Kemmei, Tomoko; Kodama, Shuji; Fujishima, Hironori; Yamamoto, Atsushi; Inoue, Yoshinori; Hayakawa, Kazuichi

    2012-01-04

    The chelating agent EDTA is widely used, and as a result is showing up widely in the aquatic environment. Here we describe a preconcentration procedure for measuring EDTA concentration in sea water samples by HPLC. The procedure consists of forming an Fe(III) complex followed by solid-phase extraction using an activated carbon cartridge. After the preconcentration, EDTA was quantified by HPLC with ultraviolet detection (260 nm). The enrichment permitted the determination of EDTA at concentrations as low as 1 nM. Good recoveries were obtained for both brackish and full-strength sea water with high repeatability (RSD<6%). The method was applied to sea water samples taken from near the mouth of the Oyabe River in Japan. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices.

    Science.gov (United States)

    Mashile, Geaneth Pertunia; Nomngongo, Philiswa N

    2017-03-04

    Cyanotoxins are toxic and are found in eutrophic, municipal, and residential water supplies. For this reason, their occurrence in drinking water systems has become a global concern. Therefore, monitoring, control, risk assessment, and prevention of these contaminants in the environmental bodies are important subjects associated with public health. Thus, rapid, sensitive, selective, simple, and accurate analytical methods for the identification and determination of cyanotoxins are required. In this paper, the sampling methodologies and applications of solid phase-based sample preparation methods for the determination of cyanotoxins in environmental matrices are reviewed. The sample preparation techniques mainly include solid phase micro-extraction (SPME), solid phase extraction (SPE), and solid phase adsorption toxin tracking technology (SPATT). In addition, advantages and disadvantages and future prospects of these methods have been discussed.

  20. Solid phase extraction-electrospray ionization mass spectrometric method for the determination of palladium

    International Nuclear Information System (INIS)

    Pranaw Kumar; Telmore, Vijay M.; Jaison, P.G.; Sarkar, Arnab; Alamelu, D.; Aggarwal, S.K.

    2015-01-01

    Platinum group of element (PGEs) are extensively used as a catalyst and anticancer reagent. Due to the soft nature of PGEs, sulphur based donar ligands are used for the separation of these elements. Studies on the formation of different species are helpful for obtaining the ideas about separation of these elements from the complex matrices. Palladium (Pd) is studied as a representative element which is also formed by nuclear fission of fissile nuclides. In view of the relatively small amount of solvent required for separation, solid phase extraction is preferred over most of the separation methods. Solid phase extraction method using DPX as a stationary phase was previously reported for the separation of Pd in SHLLW using benzoylthiourea as a ligand. However, in case of large volume samples manual extraction by DPX is tedious task. In the present studies, the feasibility of extraction using benzoylthiourea on automated solid phase extraction system was carried out for the extraction of Pd

  1. Fully automated synthesis of 11C-acetate as tumor PET tracer by simple modified solid-phase extraction purification

    International Nuclear Information System (INIS)

    Tang, Xiaolan; Tang, Ganghua; Nie, Dahong

    2013-01-01

    Introduction: Automated synthesis of 11 C-acetate ( 11 C-AC) as the most commonly used radioactive fatty acid tracer is performed by a simple, rapid, and modified solid-phase extraction (SPE) purification. Methods: Automated synthesis of 11 C-AC was implemented by carboxylation reaction of MeMgBr on a polyethylene Teflon loop ring with 11 C-CO 2 , followed by acidic hydrolysis with acid and SCX cartridge, and purification on SCX, AG11A8 and C18 SPE cartridges using a commercially available 11 C-tracer synthesizer. Quality control test and animals positron emission tomography (PET) imaging were also carried out. Results: A high and reproducible decay-uncorrected radiochemical yield of (41.0±4.6)% (n=10) was obtained from 11 C-CO 2 within the whole synthesis time about 8 min. The radiochemical purity of 11 C-AC was over 95% by high-performance liquid chromatography (HPLC) analysis. Quality control test and PET imaging showed that 11 C-AC injection produced by the simple SPE procedure was safe and efficient, and was in agreement with the current Chinese radiopharmaceutical quality control guidelines. Conclusion: The novel, simple, and rapid method is readily adapted to the fully automated synthesis of 11 C-AC on several existing commercial synthesis module. The method can be used routinely to produce 11 C-AC for preclinical and clinical studies with PET imaging. - Highlights: • A fully automated synthesis of 11 C-acetate by simple modified solid-phase extraction purification has been developed. • Typical non-decay-corrected yields were (41.0±4.6)% (n=10) • Radiochemical purity was determined by radio-HPLC analysis on a C18 column using the gradient program, instead of expensive organic acid column or anion column. • QC testing (RCP>99%)

  2. A simple method to separate red wine nonpolymeric and polymeric phenols by solid-phase extraction.

    Science.gov (United States)

    Pinelo, Manuel; Laurie, V Felipe; Waterhouse, Andrew L

    2006-04-19

    Simple polyphenols and tannins differ in the way that they contribute to the organoleptic profile of wine and their effects on human health. Very few straightforward techniques to separate red wine nonpolymeric phenols from the polymeric fraction are available in the literature. In general, they are complex, time-consuming, and generate large amounts of waste. In this procedure, the separation of these compounds was achieved using C18 cartridges, three solvents with different elution strengths, and pH adjustments of the experimental matrices. Two full factorial 2(3) experimental designs were performed to find the optimal critical variables and their values, allowing for the maximization of tannin recovery and separation efficiency (SE). Nonpolymeric phenols such as phenolic acids, monomers, and oligomers of flavonol and flavan-3-ols and anthocyanins were removed from the column by means of an aqueous solvent followed by ethyl acetate. The polymeric fraction was then eluted with a combination of methanol/acetone/water. The best results were attained with 1 mL of wine sample, a 10% methanol/water solution (first eluant), ethyl acetate (second eluant), and 66% acetone/water as the polymeric phenols-eluting solution (third eluant), obtaining a SE of ca. 90%. Trials with this method on fruit juices also showed high separation efficiency. Hence, this solid-phase extraction method has been shown to be a simple and efficient alternative for the separation of nonpolymeric phenolic fractions and the polymeric ones, and this method could have important applications to sample purification prior to biological testing due to the nonspecific binding of polymeric phenolics to nearly all enzymes and receptor sites.

  3. Platform construction and extraction mechanism study of magnetic mixed hemimicelles solid-phase extraction

    Science.gov (United States)

    Xiao, Deli; Zhang, Chan; He, Jia; Zeng, Rong; Chen, Rong; He, Hua

    2016-12-01

    Simple, accurate and high-throughput pretreatment method would facilitate large-scale studies of trace analysis in complex samples. Magnetic mixed hemimicelles solid-phase extraction has the power to become a key pretreatment method in biological, environmental and clinical research. However, lacking of experimental predictability and unsharpness of extraction mechanism limit the development of this promising method. Herein, this work tries to establish theoretical-based experimental designs for extraction of trace analytes from complex samples using magnetic mixed hemimicelles solid-phase extraction. We selected three categories and six sub-types of compounds for systematic comparative study of extraction mechanism, and comprehensively illustrated the roles of different force (hydrophobic interaction, π-π stacking interactions, hydrogen-bonding interaction, electrostatic interaction) for the first time. What’s more, the application guidelines for supporting materials, surfactants and sample matrix were also summarized. The extraction mechanism and platform established in the study render its future promising for foreseeable and efficient pretreatment under theoretical based experimental design for trace analytes from environmental, biological and clinical samples.

  4. Tetraphenylimidodiphosphinate as solid phase extractant for preconcentrative separation of thorium from aqueous solution

    International Nuclear Information System (INIS)

    Na Liu; Yanfei Wang; Chuhua He

    2016-01-01

    A simple and reliable method for solid phase extraction of thorium using tetraphenylimidodiphosphinate is presented. The solid phase extraction process was optimized at equilibrium time 3 h, pH = 4.5, initial concentration 30 mg L -1 and extractant dosage 0.01 g with 98.95 % of removal efficiency and 29.68 mg g -1 of adsorption capacity. The interfering ions experiments indicated that it had almost no effect on thorium adsorption. Kinetics data follow the pseudo-first-order model and equilibrium data agreed with the Langmuir isotherm model very well. FT-IR analysis indicated that imino group and phosphoryl acted as the significant roles in the solid phase extraction process. (author)

  5. A solid-phase extraction method for rapidly determining the adsorption coefficient of pharmaceuticals in sewage sludge

    Science.gov (United States)

    Berthod, Laurence; Roberts, Gary; Whitley, David C.; Sharpe, Alan; Mills, Graham A.

    2014-01-01

    The partitioning of pharmaceuticals in the environment can be assessed by measuring their adsorption coefficients (Kd) between aqueous and solid phases. Measuring this coefficient in sewage sludge gives an indication of their partitioning behaviour in a wastewater treatment plant and hence contributes to an understanding of their subsequent fate. The regulatory approved method for measuring Kd in sewage sludge is the US Environmental Protection Agency's Office of Prevention, Pesticides and Toxic Substances (OPPTS) guideline 835.1110, which is labour intensive and time consuming. We describe an alternative method for measuring the Kd of pharmaceuticals in sewage sludge using a modified solid-phase extraction (SPE) technique. SPE cartridges were packed at different sludge/PTFE ratios (0.4, 6.0, 24.0 and 40.0% w/w sludge) and eluted with phosphate buffer at pH 7.4. The approach was tested initially using three pharmaceuticals (clofibric acid, diclofenac and oxytetracycline) that covered a range of Kd values. Subsequently, the sorption behaviour of ten further pharmaceuticals with varying physico-chemical properties was evaluated. Results from the SPE method were comparable to those of the OPPTS test, with a correlation coefficient of 0.93 between the two approaches. SPE cartridges packed with sludge and PTFE were stable for up to one year; use within one month reduced variability in measurements (to a maximum of 0.6 log units). The SPE method is low-cost, easy to use and enables the rapid measurement of Kd values for a large number of chemicals. It can be used as an alternative to the more laborious full OPPTS test in environmental fate studies and risk assessments. PMID:25299795

  6. Solid-phase extraction of berries’ anthocyanins and evaluation of their antioxidative properties

    Czech Academy of Sciences Publication Activity Database

    Denev, P.; Číž, Milan; Ambrožová, Gabriela; Lojek, Antonín; Yanakieva, I.; Kratchanova, M.

    2010-01-01

    Roč. 123, č. 4 (2010), s. 1055-1061 ISSN 0308-8146 R&D Projects: GA MŠk(CZ) OC08058 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : anthocyanins * solid-phase extraction * berry extracts Subject RIV: BO - Biophysics Impact factor: 3.458, year: 2010

  7. Solid phase extraction of hydroxyaromatic compounds from aquatic environment

    Directory of Open Access Journals (Sweden)

    P. T. Sukhanov

    2012-01-01

    Full Text Available The dependence of extraction parameters of hydroxyaromatic compounds on sort of polyurethane foam, nature and composition of solution deposited on a polymer foam, content of inorganic salt in solution.

  8. Solid-phase extraction and determination of trace elements in environmental samples using naphthalene adsorbent

    International Nuclear Information System (INIS)

    Pourreza, N.

    2004-01-01

    Naphthalene co-precipitated with quaternary ammonium salt such as tetraoctyl ammonium bromide and methyltrioctyl ammonium chloride have been used as adsorbent for solid phase extraction of metal ions such as Hg, Cd and Fe. The metal ions are retained on the adsorbent in a column as their complexes with suitable ligands and eluted by an eluent before instrumental measurements. The optimization of the procedures for solid phase extraction and consequent determination of trace elements and application to environmental samples especially water samples will be discussed. (author)

  9. Solid-phase extraction procedures in systematic toxicological analysis

    NARCIS (Netherlands)

    Franke, J.P.; de Zeeuw, R.A

    1998-01-01

    In systematic toxicological analysis (STA) the substance(s) present is (are) not known at the start of the analysis. in such an undirected search the extraction procedure cannot be directed to a given substance but must be a general procedure where a compromise must be reached in that the substances

  10. after solid phase extraction on modified sawdust s

    African Journals Online (AJOL)

    Preferred Customer

    extraction (SPE) techniques are widely used for the determination of trace metal ions in aqueous samples, because ... adsorption resin [16] and modified activated carbon [17]. ... washed with distilled water, and dried in oven at 40 ºC for 24 h.

  11. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  12. [Determination of patulin in fruits and jam by solid phase extraction-ultra performance liquid chromatography].

    Science.gov (United States)

    Lü, Weichao; Shen, Shuchang; Wang, Chao

    2017-11-08

    With magnesium silicate, silica gel, diatomite and calcium sulfate as raw materials, a new solid phase extraction column was prepared through a series of processes of grinding to ethanol homogenate, drying and packing into polypropylene tube. The sample was hydrolyzed by pectinase, extracted by acetonitrile and purified by solid phase extraction. The target compounds were separated on a C18 column (100 mm×2.1 mm, 1.8 μm), using 0.8% (v/v) tetrahydrofuran solution as mobile phase with a flow rate of 0.5 mL/min. The detection wavelength was 276 nm. The effect of pectinase on extraction yield and purification effect of solid-phase extraction column were investigated. The optimum chromatographic conditions were selected. There was a good linear relationship between the peak heights and the mass concentrations of patulin in the range of 0.1 to 10 mg/L with the correlation coefficient ( R 2 ) of 1. The limit of detection for this method was 10.22 μg/kg. The spiked recoveries of samples were 86.58%-94.84% with the relative standard deviations (RSDs) of 1.45%-2.28%. The results indicated that the self-made solid phase extraction column had a good purification efficiency, and the UPLC had a high separation efficiency. The method is simple, accurate and of great significance for the quality and safety control of fruit products.

  13. Hexagonal boron nitride nanosheets as adsorbents for solid-phase extraction of polychlorinated biphenyls from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Shiliang; Wang, Zhenhua; Ding, Ning [Key Laboratory for Applied Technology of Sophisticated Analytical Instruments, Shandong Academy of Sciences, Jinan, Shandong (China); Elaine Wong, Y.-L. [Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Chen, Xiangfeng, E-mail: xiangfchensdas@163.com [Key Laboratory for Applied Technology of Sophisticated Analytical Instruments, Shandong Academy of Sciences, Jinan, Shandong (China); Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Qiu, Guangyu [Department of Physics and Materials Science, City University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong); Dominic Chan, T.-W., E-mail: twdchan@cuhk.edu.hk [Department of Chemistry, The Chinese University of Hong Kong, Hong Kong Special Administrative Region (Hong Kong)

    2016-09-14

    The adsorptive potential of hexagonal boron nitride nanosheets (h-BNNSs) for solid-phase extraction (SPE) of pollutants was investigated for the first time. Seven indicators of polychlorinated biphenyls (PCBs) were selected as target analytes. The adsorption of PCBs on the surface of the h-BNNSs in water was simulated by the density functional theory and molecular dynamics. The simulation results indicated that the PCBs are adsorbed on the surface by π–π, hydrophobic, and electrostatic interactions. The PCBs were extracted with an h-BNNS-packed SPE cartridge, and eluted by dichloromethane. Gas chromatography–tandem mass spectrometry working in the multiple reaction monitor mode was used for the sample quantification. The effect of extraction parameters, including the flow rate, pH value, breakthrough volume, and the ionic strength, were investigated. Under the optimal working conditions, the developed method showed low limits of detection (0.24–0.50 ng L{sup −1}; signal-to-noise ratio = 3:1), low limits of quantification (0.79–1.56 ng L{sup −1}; signal-to-noise ratio = 10:1), satisfactory linearity (r > 0.99) within the concentration range of 2–1000 ng L{sup −1}, and good precision (relative standard deviation < 12%). The PCBs concentration in environmental water samples was determined by the developed method. This results demonstrate that h-BNNSs have high analytical potential in the enrichment of pollutants. - Highlights: • The hexagonal boron nitride nanosheets were synthesized. • The nanosheets were used as adsorbent for solid-phase extraction. • The h-BN demonstrates remarkable adsorption of PCBs from water samples. • The method was successfully applied in determination of PCBs in water samples.

  14. Application of cation-exchange solid-phase extraction for the analysis of amino alcohols from water and human plasma for verification of Chemical Weapons Convention.

    Science.gov (United States)

    Kanaujia, Pankaj K; Tak, Vijay; Pardasani, Deepak; Gupta, A K; Dubey, D K

    2008-03-28

    The analysis of nitrogen containing amino alcohols, which are the precursors and degradation products of nitrogen mustards and nerve agent VX, constitutes an important aspect for verifying the compliance to the CWC (Chemical Weapons Convention). This work devotes on the development of solid-phase extraction method using silica- and polymer-based SCX (strong cation-exchange) and MCX (mixed-mode strong cation-exchange) cartridges for N,N-dialkylaminoethane-2-ols and alkyl N,N-diethanolamines, from water. The extracted analytes were analyzed by GC-MS (gas chromatography-mass spectrometry) in the full scan and selected ion monitoring modes. The extraction efficiencies of SCX and MCX cartridges were compared, and results revealed that SCX performed better. Extraction parameters, such as loading capacity, extraction solvent, its volume, and washing solvent were optimized. Best recoveries were obtained using 2 mL methanol containing 10% NH(4)OH and limits of detection could be achieved up to 5 x 10(-3) microg mL(-1) in the selected ion monitoring mode and 0.01 microg mL(-1) in full scan mode. The method was successfully employed for the detection and identification of amino alcohol present in water sample sent by Organization for Prohibition of Chemical Weapons (OPCW) in the official proficiency tests. The method was also applied to extract the analytes from human plasma. The SCX cartridge showed good recoveries of amino alcohols from human plasma after protein precipitation.

  15. Solid-phase micro-extraction in bioanalysis, exemplified by lidocaine determination

    NARCIS (Netherlands)

    de Jong, GJ; Koster, EHM

    2000-01-01

    Solid-phase micro-extraction (SPME) is a never sample preparation technique that can be used for gaseous, liquid or solid samples in conjunction with GC, HPLC or CE (e.g. [1]). The use of SPME for the analysis of drugs in biofluids is also becoming popular (e.g. [2]). The principle is that a fused

  16. Technical note: New applications for on-line automated solid phase extraction

    OpenAIRE

    MacFarlane, John D.

    1997-01-01

    This technical note explains the disadvantages of manual solid phase extraction (SPE) techniques and the benefits to be gained with automatic systems. The note reports on a number of general and highly specific applications using the Sample Preparation Unit OSP-2A.

  17. Development of an interface for directly coupled solid-phase extraction and GC-MS analysis

    NARCIS (Netherlands)

    Öllers, M.J.H.; van Lieshout, H.P.M.; Janssen, J.G.M.; Cramers, C.A.M.G.

    Solid-phase extraction (SPE) is widely used as a sample preparation technique in numerous application areas of chromatography. Large-volume injection is an attractive technique for coupling SPE to gas chromatography (GC) because it provides improved detection limits and circumvents the need for

  18. A New Solid Phase Extraction for the Determination of Anthocyanins in Grapes

    Directory of Open Access Journals (Sweden)

    Marta Ferreiro-González

    2014-12-01

    Full Text Available A method for the concentration and cleaning of red grape extracts prior to the determination of anthocyanins by UPLC-DAD has been developed. This method is of special interest in the determination of phenolic maturity as it allows the analysis of the anthocyanins present in grapes. Several different SPE cartridges were assessed, including both C-18- and vinylbenzene-based cartridges. C-18-based cartridges presented a very low retention for the glucosylated anthocyanidins while vinylbenzene-based cartridges showed excellent retention for these compounds. The optimized method involves the initial conditioning of the cartridge using 10 mL of methanol and 10 mL of water, followed by loading of up to 100 mL of red grape extract. Ten mL of water was used in the washing step and anthocyanins were subsequently eluted using 1.5 mL of acidified methanol at pH 2. This method simplifies the determination of individual anthocyanins as, on the one hand, it cleans the sample of interference and, on the other hand, it increases the concentration to up to 25:1.5. The developed method has been validated with a range of different grapes and it has also been tested as a means of determining the different anthocyanins in grapes with different levels of maturity.

  19. Molecularly imprinted solid-phase extraction in the analysis of agrochemicals.

    Science.gov (United States)

    Yi, Ling-Xiao; Fang, Rou; Chen, Guan-Hua

    2013-08-01

    The molecular imprinting technique is a highly predeterminative recognition technology. Molecularly imprinted polymers (MIPs) can be applied to the cleanup and preconcentration of analytes as the selective adsorbent of solid-phase extraction (SPE). In recent years, a new type of SPE has formed, molecularly imprinted polymer solid-phase extraction (MISPE), and has been widely applied to the extraction of agrochemicals. In this review, the mechanism of the molecular imprinting technique and the methodology of MIP preparations are explained. The extraction modes of MISPE, including offline and online, are discussed, and the applications of MISPE in the analysis of agrochemicals such as herbicides, fungicides and insecticides are summarized. It is concluded that MISPE is a powerful tool to selectively isolate agrochemicals from real samples with higher extraction and cleanup efficiency than commercial SPE and that it has great potential for broad applications.

  20. Simultaneous detection of nine cyanotoxins in drinking water using dual solid-phase extraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Yen, Hung-Kai; Lin, Tsair-Fuh; Liao, Pao-Chi

    2011-08-01

    A solid-phase extraction (SPE)-liquid chromatography (LC)-mass spectrometry (MS) method was developed to concentrate and detect nine cyanotoxins simultaneously, including six microcystins (MCs) congeners, nodularin (NOD), anatoxin-a (ATX) and cylindrospermopsin (CYN), in pure and natural waters. A dual cartridge SPE assembly was tested for the operating parameters of cyanotoxin extraction. A surrogate standard (SS), 1,9-diaminononane, was spiked in all the samples before the SPE extraction, and an internal standard (IS), 2,3,5-trimethylphenyl methyl carbamate, was spiked before LC/MS analysis. The method detection limit (MDL) was 2-100 ng/L for nine cyanotoxins in pure water and was increased by a factor of three to ten in a more complicated water matrix. The recoveries based on SS were between 83 and 104%, while those based on IS were 80-120%. The developed method was successfully employed in analyzing 33 water samples collected from eutrophic lakes, water treatment plants and distribution taps. MCs, NOD, and CYN were detected in the reservoir water, with concentrations as high as 36 μg/L. In addition, for the first time in Taiwan's tap water, CYN was detected at concentrations as high as 8.6 μg/L. Quality control data for the field samples shows that the analytical scheme developed is appropriate for monitoring cyanotoxins. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Preconcentration of trace uranium from seawater with solid phase extraction followed by differential pulse polarographic determination in chloroform eluate

    International Nuclear Information System (INIS)

    Dojozan, Dj.; Pournaghi-Azar, M.H.; Toutounchi-Asr, J.

    1998-01-01

    In the present study, an effective method is presented for the separation and preconcentration of uranium (VI) by solid phase extraction (SPE). For this purpose, U(VI) oxinate is formed by the reaction of U(VI) with 8-hydroxyquinoline and adsorbed onto the octylsilane (C-8) SPE cartridge. The analyte is completely eluted with chloroform and determined by differential pulse polarography. The SPE conditions were optimized by evaluating the effective factors such as pH, oxine concentration, type and concentration of buffer and masking agent. By the proposed method a preconcentration factor of more than 100 was achieved. The average recovery of uranium (VI) oxinate (0.1 mg l -1 ) was 99.8%. The relative standard deviation was 1.6% for seven replicate determinations of uranyl ion in the solution with a concentration 20 μg l -1 . Some concomitant ions such as Ca +2 , Mg +2 and Fe +3 which interfere in extraction or determination process of uranium were masked with EDTA in aqueous phase during the extraction process. The proposed method was successfully used for the determination of uranium in Caspian Sea and Persian Gulf water samples

  2. Solid phase extraction and metabolic profiling of exudates from living copepods

    DEFF Research Database (Denmark)

    Selander, Erik; Heuschele, Jan; Nylund, Göran M.

    2016-01-01

    describe the development of a closed loop solid phase extraction setup that allows for extraction of exuded metabolites from live copepods. We captured exudates from male and female Temora longicornis and analyzed the content with high resolution LC-MS. Chemometric methods revealed 87 compounds...... that solid phase extraction in combination with metabolic profiling of exudates is a useful tool to develop our understanding of the chemical interplay between pelagic organisms....... Copepodamide G, known to induce defensive responses in phytoplankton, was among the ten compounds of highest relative abundance in both male and female extracts. The presence of copepodamide G shows that the method can be used to capture and analyze chemical signals from living source organisms. We conclude...

  3. Determination of ciprofloxacin in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with fluorescence detection

    International Nuclear Information System (INIS)

    Lian, Ziru; Wang, Jiangtao

    2016-01-01

    A high selective pre-treatment method for the cleanup and preconcentration of ciprofloxacin in natural seawater samples was developed based on molecularly imprinted solid-phase extraction (MISPE). The ciprofloxacin imprinted polymers were synthesized and the characteristics of obtained polymers were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy and binding experiments. The imprinted materials showed high adsorption ability for ciprofloxacin and were applied as special solid-phase extraction sorbents for selective separation of ciprofloxacin. An off-line MISPE procedure was optimized and the developed MISPE method allowed direct purification and enrichment of the ciprofloxacin from the aqueous samples prior to high-performance liquid chromatography analysis. The recoveries of spiked seawater on the MISPE cartridges ranged from 75.2 to 112.4% and the relative standard deviations were less than 4.46%. Five seawater samples from Jiaozhou Bay were analyzed and ciprofloxacin was detected in two samples with the concentrations of 0.24 and 0.38 μg L −1 , respectively. - Highlights: • Ciprofloxacin molecularly imprinted polymers (Cip-MIPs) were prepared. • The characteristics and recognition efficiency of MIPs were studied. • An off-line method for Cip was developed using MIPs as solid-phase extraction. • Cip in five seawater samples from Jiaozhou Bay of China was determined.

  4. Simultaneous solid phase extraction of cobalt, strontium and cesium from liquid radioactive waste using microcrystalline naphthalene

    International Nuclear Information System (INIS)

    Hamed, Mostafa Mohamed; Attallah, Mohamed Fathy; Metwally, Sayed Sayed

    2014-01-01

    Most of the procedures developed for the extraction of cobalt, strontium and cesium by solid phase extraction do not employ simultaneous extraction of them. In this study, rapid simultaneous removal of Co 2+ , Sr 2+ and Cs + on microcrystalline naphthalene as solid-phase extractant was investigated. These ions were allowed to form chelates with oxine and then adsorbed on freshly microcrystalline naphthalene from aqueous solutions. The solid phase extraction procedure (SPE) was optimized by using model solution containing Co 2+ , Sr 2+ and Cs + in batch system. The effects of different parameters such as variation in pH, reagent concentration, standing time, naphthalene solution concentration and contact time on the simultaneous removal of these ions was studied. The obtained results indicated that, sorption was found to be rapid, and the percentage removal of Co 2+ , Sr 2+ and Cs + was found to be 98, 79 and 68% within 10 min, respectively. The kinetics of the sorption process was investigated to understand the kinetic characteristics of sorption of metal chelates onto microcrystalline naphthalene. The developed procedure has been successfully applied to the removal and recovery of 60 Co and 134 Cs from liquid radioactive waste. The parameters can be used for designing a plant for treatment of wastewater economically.

  5. Simultaneous Analysis of Simple Coumarins and Furocoumarines in Cigarettes by Solid-Phase Extraction with Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Zheng, Yang; Xu, Xiuli; Yuan, Fei; Yao, Meiyi; Ji, Shunli; Huang, Zhiqiang; Zhang, Feng

    2017-09-01

    A sensitive, high-throughput analytical method based on a GC-MS method was established for the simultaneous quantitative determination of two categories of harmful coumarins: simple coumarins (coumarin, 6-methylcoumarin, 7-methoxycoumarin, 3,4-dihydrocoumarin, and 7-ethoxy-4-methylcoumarin) and furocoumarines (psoralen, 8-methoxypsoralen, 5-methoxypsoralen, and trioxysalen). The nine analytes were extracted with ethyl acetate, purified with Oasis HLB solid-phase extraction (SPE) cartridges, and identified and quantitatively determined by GC-MS in selected-ion monitoring mode. The LODs and LOQs of these compounds were in the ranges of 12.5-21.2 and 41.6-70.0 μg/kg, respectively. Average recoveries for the nine analytes ranged from 72.7 to 86.6% at LOQ, 1.5× LOQ, and 2× LOQ spike levels, with RSDs that were typically lower than 5.1%. The SPE-GC-MS method developed in this study was initially applied to research coumarins in cigarette samples; it proved to be accurate, sensitive, convenient, and practical.

  6. DETERMINATION OF MUSHROOM TOXIN ALPHA-AMANITIN IN SERUM BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AFTER SOLID-PHASE EXTRACTION

    Directory of Open Access Journals (Sweden)

    Maja Vujović

    2015-03-01

    Full Text Available Alpha-amanitin is a cyclic peptide which belongs to a large group of mushroom toxins known as amatoxins. Being responsible for the majority of fatal mushroom poisonings, they require rapid detection and excretion from the body fluids. In accordance with these requirements, a simple and an accurate method was developed for successful identification and quantification of alpha-amanitin in serum with electrospray liquid chromatography–mass spectrometry (LC-ESI-MS after collision-induced dissociation. The method conforms to the established International Conference on Harmonization Q2A/Q2B 1996 guidelines on the validation of analytical methods. Linearity, precision, extraction recovery and stability test on blank serum spiked with alpha-amanitin and stored in different conditions met the acceptance criteria. The obtained calibration curve was linear over the concentration range 5-100 ng/mL with a lower limit of quantification (LOQ of 5 ng/mL and limit of detection (LOD of 2.5 ng/mL. The mean intra- and inter-day precision and accuracy were 6.05% and less than ±15% of nominal values, respectively. The neutral solid phase extraction with copolymer hydrophilic–lipophilic balance cartridges was found optimal for sample preparation with the mean recovery of 91.94%. The proposed method demonstrated high sensitivity and selectivity which can be useful both for clinical and forensic toxicology analysis of alpha-amanitin at low concentrations.

  7. Sistema limpo em linha para extração em fase sólida de contaminantes emergentes em águas naturais An in-line clean system for the solid-phase extraction of emerging contaminants in natural waters

    Directory of Open Access Journals (Sweden)

    Fernando F. Sodré

    2010-01-01

    Full Text Available A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L using commercial solid-phase extraction (SPE cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.

  8. Microwave assisted solid phase extraction for separation preconcentration sulfamethoxazole in wastewater using tyre based activated carbon as solid phase material prior to spectrophotometric determination

    Science.gov (United States)

    Mogolodi Dimpe, K.; Mpupa, Anele; Nomngongo, Philiswa N.

    2018-01-01

    This work was chiefly encouraged by the continuous consumption of antibiotics which eventually pose harmful effects on animals and human beings when present in water systems. In this study, the activated carbon (AC) was used as a solid phase material for the removal of sulfamethoxazole (SMX) in wastewater samples. The microwave assisted solid phase extraction (MASPE) as a sample extraction method was employed to better extract SMX in water samples and finally the analysis of SMX was done by the UV-Vis spectrophotometer. The microwave assisted solid phase extraction method was optimized using a two-level fractional factorial design by evaluating parameters such as pH, mass of adsorbent (MA), extraction time (ET), eluent ratio (ER) and microwave power (MP). Under optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.5 μg L- 1 and 1.7 μg L- 1, respectively, and intraday and interday precision expressed in terms of relative standard deviation were > 6%.The maximum adsorption capacity was 138 mg g- 1 for SMX and the adsorbent could be reused eight times. Lastly, the MASPE method was applied for the removal of SMX in wastewater samples collected from a domestic wastewater treatment plant (WWTP) and river water.

  9. Determination of volatile compounds in grape distillates by solid-phase extraction and gas chromatography.

    Science.gov (United States)

    Lukić, Igor; Banović, Mara; Persurić, Dordano; Radeka, Sanja; Sladonja, Barbara

    2006-01-06

    Solid-phase extraction (SPE) procedure on octadecylsilica (C18) was developed for accumulation of volatile compounds from grape distillates. The procedure was optimised for final analysis by capillary gas chromatography. At mass concentrations in model solutions ranging from 0.1 to 50 mg/l solid-phase extraction recoveries of all analytes ranged from 69% for 2-phenylethanol to 102% for capric acid, with RSD values from 2 to 9%. SPE recoveries of internal standards to be added in the sample solution prior to extraction, higher alcohols 2-ethyl-1-hexanol and 1-undecanol, were 97 and 93%, respectively, with RSD values of 3%. Detection limits of analyzed compounds in model solutions ranged from 0.011 mg/l for isoamyl acetate to 0.037 mg/l for caproic acid. Method efficiency was tested in relation to acetic acid content, volume fraction of ethanol and possible matrix effects. A significant influence of matrix on SPE efficiency for geraniol, cis-2-hexen-1-ol and cis-3-hexen-1-ol was detected. For the same reason, 2-phenylethanol could not be determined by developed SPE method in samples of grape distillates. The developed solid-phase extraction method was successfully applied to determine the differences in volatile compound content in different grape distillates produced by the distillation of crushed, pressed and fermented grapes.

  10. Solid-phase extraction NMR studies of chromatographic fractions of saponins from Quillaja saponaria.

    Science.gov (United States)

    Nyberg, Nils T; Baumann, Herbert; Kenne, Lennart

    2003-01-15

    The saponin mixture QH-B from the tree Quillaja saponaria var. Molina was fractionated by RP-HPLC in several steps. The fractions were analyzed by solid-phase extraction NMR (SPE-NMR), a technique combining the workup by solid-phase extraction with on-line coupling to an NMR flow probe. Together with MALDI-TOF mass spectrometry and comparison with chemical shifts of similar saponins, the structures of both major and minor components in QH-B could be obtained. The procedure described is a simple method to determine the structure of components in a complex mixture. The two major fractions of the mixture were found to contain at least 28 saponins, differing in the carbohydrate substructures. Eight of these have not previously been determined. The 28 saponins formed 14 equilibrium pairs by the migration of an O-acyl group between two adjacent positions on a fucosyl residue.

  11. Visual monitoring of solid-phase extraction using chromogenic fluorous synthesis supports.

    Science.gov (United States)

    Blackburn, Christopher

    2012-03-12

    Reductive aminations and further transformations of an azo dye and fluorous tagged aldehyde are described. The intensely colored 2,4-dialkoxybenzyl protected amines undergo Fmoc-based peptide coupling, Suzuki reactions, and sulfonamide formation with product isolation facilitated by visual monitoring of fluorous solid phase extraction. Target compounds are released from the supports in high yields and purities by treatment with trifluoroacetic acid (TFA).

  12. HPLC WITH SOLID PHASE EXTRACTION FOR IDENTIFICATION AND DIAGNOSIS OF ORGANOPHOSPHOROUS POISONING IN GOATS

    Directory of Open Access Journals (Sweden)

    S. Manna

    2014-12-01

    Full Text Available High performance liquid chromatographic determination of organophosphorous compound has been done by reverse phase chromatography in goats. The goats were dying showing the symptoms of organophosphorous poisoning. The viscera and stomach contents sample were received from Project Co-Ordinator, Animal Disease Research Institute, Phulnakhara, Cuttack, Orissa. The analysis of samples by HPLC with UV detector after cleaning up in Solid Phase Extraction (SPE revealed presence of malathion that was later quantified.

  13. Integration of Solid-phase Extraction with Electrothermal Atomic Absorption Spectrometry for Determination of Trace Elements

    OpenAIRE

    NUKATSUKA, Isoshi; OHZEKI, Kunio

    2006-01-01

    An enrichment step in a sample treatment is essential for trace analysis to improve the sensitivity and to eliminate the matrix of the sample. Solid-phase extraction (SPE) is one of the widely used enrichment technique. Electrothermal atomic absorption spectrometry (ETAAS) is a well-established determination technique for trace elements. The integration of SPE with ETAAS leads to further improvement of sensitivity, an automation of the measurement and the economy in the sample size, amounts o...

  14. Determination of organophosphorus pesticides using molecularly imprinted polymer solid phase extraction

    International Nuclear Information System (INIS)

    Mohd Marsin Sanagi; Syairah Salleh; Wan Aini Wan Ibrahim

    2011-01-01

    Molecularly imprinted polymer solid phase extraction (MIP-SPE) method has been developed for the determination of organophosphorus pesticides (OPPs) in water samples. The MIP was prepared by thermo-polymerization method using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as crosslinker, acetonitrile as porogenic solvent and quinalphos as the template molecule. The three OPPs (diazinon, quinalphos and chloropyrifos) were selected as target analytes as they are widely used in agriculture sector. Various parameters affecting the extraction efficiency of the imprinted polymers have been evaluated to optimize the selective preconcentration of OPPs from aqueous samples. The characteristics of the MIP-SPE method were validated by high performance liquid chromatography (HPLC). The accuracy and selectivity of the MIP-SPE process developed were verified using non-imprinted polymer solid phase extraction (NIP-SPE) and a commercial C 18 -SPE was used for comparison. The recoveries of the target analytes obtained using the MIPs as the solid phase sorbent ranged from 83% to 98% (RSDs 1.05 - 1.98 %; n=3) for water sample. The developed MIP-SPE method demonstrates that it could be applied for the determination of OPPs in water samples. (author)

  15. Solid phase extraction for the speciation and preconcentration of inorganic selenium in water samples: a review.

    Science.gov (United States)

    Herrero Latorre, C; Barciela García, J; García Martín, S; Peña Crecente, R M

    2013-12-04

    Selenium is an essential element for the normal cellular function of living organisms. However, selenium is toxic at concentrations of only three to five times higher than the essential concentration. The inorganic forms (mainly selenite and selenate) present in environmental water generally exhibit higher toxicity (up to 40 times) than organic forms. Therefore, the determination of low levels of different inorganic selenium species in water is an analytical challenge. Solid-phase extraction has been used as a separation and/or preconcentration technique prior to the determination of selenium species due to the need for accurate measurements for Se species in water at extremely low levels. The present paper provides a critical review of the published methods for inorganic selenium speciation in water samples using solid phase extraction as a preconcentration procedure. On the basis of more than 75 references, the different speciation strategies used for this task have been highlighted and classified. The solid-phase extraction sorbents and the performance and analytical characteristics of the developed methods for Se speciation are also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Determination of organophosphate flame retardants in soil and fish using ultrasound-assisted extraction, solid-phase clean-up, and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Lorenzo, María; Campo, Julián; Picó, Yolanda

    2018-03-22

    A solid-liquid extraction method in combination with high-performance liquid chromatography and tandem mass spectrometry was developed and optimized for extraction and analysis of organophosphorus flame retardants in soil and fish. Methanol was chosen as the optimum extraction solvent, not only in terms of extraction efficiency, but also for its broader analyte coverage. The subsequent clean-up by solid-phase extraction is required to eliminate matrix coextractives and reduce matrix effects. Recoveries of the optimized method were 50-121% for soil and 47-123% for biota, both with high precision (RSDs solid-phase extraction cartridge clogging that increase variability and analysis time. The method was successfully applied for the determination of organophosphorus flame retardants in soil and fish from L'Albufera Natural Park (Valencia, Spain). Target compounds were detected in all soil and fish samples with values varying from 13.8 to 89.7 ng/g dry weight and from 3.3 to 53.0 ng/g wet weight, respectively. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Solid-phase extraction and HPLC assay of nicotine and cotinine in plasma and brain.

    Science.gov (United States)

    Dawson, Ralph; Messina, S M; Stokes, C; Salyani, S; Alcalay, N; De Fiebre, N C; De Fiebre, C M

    2002-01-01

    The aim of this study was to develop a simple and reliable assay for nicotine (NIC) and its major metabolite, cotinine (COT), in plasma and brain. A method was developed that uses an extraction method compatible with reverse-phase high-performance liquid chromatography (HPLC) separation and ultraviolet (UV) detection. Sequential solid-phase extraction on silica columns followed by extraction using octadecyl (C18) columns resulted in mean percent recovery (n = 5) of 51 +/- 5, 64 +/- 10, and 52 +/- 10% for NIC, COT, and phenylimidazole (PI), respectively, in spiked 1-mL serum samples. Recovery (mean +/- SEM) of the internal standard (PI) from spiked samples of nicotine-injected rats averaged 64.1 +/- 1.5% (n = 138) from plasma, and 20.7+/-0.8% (n = 128) from brain. The limits of detection of NIC in plasma samples were approximately 8 ng per mL, and of COT, 13.6 ng per mL. Further optimization of our extraction method, using slower flow rates and solid-phase extraction on silica columns, followed by C18 column extraction, yielded somewhat better recoveries (38 +/-3%) for 1-mL brain homogenates. Interassay precision (coefficient of variation) was determined on the basis of daily calibrations for 2 months and was found to be 7%, 9%, and 9% for NIC, COT, and PI, respectively, whereas intra-assay variability was 3.9% for both NIC and COT. Limited studies were performed on analytical columns for comparison of retention, resolution, asymmetry, and column capacity. We concluded that a simple two-step solid-phase extraction method, coupled with HPLC separation and UV detection, can be used routinely to measure NIC and COT in biological fluids and tissues.

  18. Fifty years of solid-phase extraction in water analysis--historical development and overview.

    Science.gov (United States)

    Liska, I

    2000-07-14

    The use of an appropriate sample handling technique is a must in an analysis of organic micropollutants in water. The efforts to use a solid phase for the recovery of analytes from a water matrix prior to their detection have a long history. Since the first experimental trials using activated carbon filters that were performed 50 years ago, solid-phase extraction (SPE) has become an established sample preparation technique. The initial experimental applications of SPE resulted in widespread use of this technique in current water analysis and also to adoption of SPE into standardized analytical methods. During the decades of its evolution, chromatographers became aware of the advantages of SPE and, despite many innovations that appeared in the last decade, new SPE developments are still expected in the future. A brief overview of 50 years of the history of the use of SPE in organic trace analysis of water is given in presented paper.

  19. Investigating the Retention Mechanisms of Liquid Chromatography Using Solid-Phase Extraction Cartridges

    Science.gov (United States)

    O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep

    2009-01-01

    Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…

  20. Determination of decamethylcyclopentasiloxane in air using commercial solid phase extraction cartridges.

    Science.gov (United States)

    Kierkegaard, Amelie; McLachlan, Michael S

    2010-05-21

    Decamethylcyclopentasiloxane (D(5)), a high production volume chemical used in personal care products, has been designated for regulation in Canada and is under review in the EU because of concerns about its persistence and potential for bioaccumulation in the environment. D(5) is a volatile compound expected to be found primarily in air, but there is little information on atmospheric concentrations due to the lack of sensitive analytical methods. Here a simple and sensitive method to determine D(5) in ambient air is presented. The challenge in the environmental analysis of D(5) is avoiding contamination. Our method is based on the high trapping efficiency of the sorbent Isolute ENV+, combined with a comparably high sampling rate. A small amount of sorbent (10 mg) is eluted in a small volume of n-hexane (0.1-0.6 mL), which is injected onto a GC/MS system without further processing. The simplicity of the method enables the use of a field blank for every sample to trace contamination. The method provides low limits of quantification (approximately 0.3 ng/m(3)), good repeatability and limited breakthrough (approximately 1%). By lowering the limit of quantification compared to published work by almost two orders of magnitude, it became possible to quantify D(5) in ambient air at locations remote from strong point sources. The concentrations at a rural Swedish site ranged from 0.7 to 8 ng/m(3) over a period of 4 months. 2010 Elsevier B.V. All rights reserved.

  1. Solid-phase extraction (SPE) of Iron using Lanthanum Silicate ion exchange

    International Nuclear Information System (INIS)

    Kiarostami, V.; Husain, W.

    2002-01-01

    Solid-phase extraction (SPE) is gaining wide use as an effective and speedy technique which reduces solvent usage, disposal costs and extraction time. The analyte is adsorbed from solution onto a solid adsorbent, which is followed by elution of the analyte with a solvent appropriate for instrumental analysis. However, there is an increasing need for new selective adsorbents to expand the area of this technique. Lanthanum silicate ion exchanger, which shows unusual selectivity elements and in this study, it was employed to develop a SPE method for iron ion. Special experiments such as determination of distribution coefficient for iron ion in different solvent systems have been determined

  2. C18, C8, and perfluoro reversed phases on diamond for solid-phase extraction.

    Science.gov (United States)

    Saini, Gaurav; Wiest, Landon A; Herbert, David; Biggs, Katherine N; Dadson, Andrew; Vail, Michael A; Linford, Matthew R

    2009-04-17

    In spite of advances in solid-phase extraction (SPE) technology there are certain disadvantages to current SPE silica-based, column packings. The pH range over which extraction can occur is limited and each column is generally only used once. New diamond-based reversed SPE phases (C(18), C(8), and perfluorinated) were developed in our laboratories. Studies were done which show that these phases do not have the same limitations as traditional silica-based stationary phases. The synthesis and properties of these diamond-based phases are presented, and the stability, percent recovery, and column capacity are given for the C(18) phase.

  3. Highly selective solid-phase extraction and large volume injection for the robust gas chromatography-mass spectrometric analysis of TCA and TBA in wines.

    Science.gov (United States)

    Insa, S; Anticó, E; Ferreira, V

    2005-09-30

    A reliable solid-phase extraction (SPE) method for the simultaneous determination of 2,4,6-trichloroanisole (TCA) and 2,4,6-tribromoanisole (TBA) in wines has been developed. In the proposed procedure 50 mL of wine are extracted in a 1 mL cartridge filled with 50 mg of LiChrolut EN resins. Most wine volatiles are washed up with 12.5 mL of a water:methanol solution (70%, v/v) containing 1% of NaHCO3. Analytes are further eluted with 0.6 mL of dichloromethane. A 40 microL aliquot of this extract is directly injected into a PTV injector operated in the solvent split mode, and analysed by gas chromatography (GC)-ion trap mass spectrometry using the selected ion storage mode. The solid-phase extraction, including sample volume and rinsing and elution solvents, and the large volume GC injection have been carefully evaluated and optimized. The resulting method is precise (RSD (%) TBA, respectively), robust (the absolute recoveries of both analytes are higher than 80% and consistent wine to wine) and friendly to the GC-MS system (the extract is clean, simple and free from non-volatiles).

  4. Solid-phase extraction assisted dispersive liquid-liquid microextraction based on solidification of floating organic droplet to determine sildenafil and its analogues in dietary supplements.

    Science.gov (United States)

    Li, Jing; Roh, Si Hun; Shaodong, Jia; Hong, Ji Yeon; Lee, Dong-Kyu; Shin, Byong-Kyu; Park, Jeong Hill; Lee, Jeongmi; Kwon, Sung Won

    2017-08-01

    A novel analytical method for the simultaneous determination of the concentration of sildenafil and its five analogues in dietary supplements using solid-phase extraction assisted reversed-phase dispersive liquid-liquid microextraction based on solidification of floating organic droplet combined with ion-pairing liquid chromatography with an ultraviolet detector was developed. Parameters that affect extraction efficiency were systematically investigated, including the type of solid-phase extraction cartridge, pH of the extraction environment, and the type and volume of extraction and dispersive solvent. The method linearity was in the range of 5.0-100 ng/mL for sildenafil, homosildenafil, udenafil, benzylsildenafil, and thiosildenafil and 10-100 ng/mL for acetildenafil. The coefficients of determination were ≥0.996 for all regression curves. The sensitivity values expressed as limit of detection were between 2.5 and 7.5 ng/mL. Furthermore, intraday and interday precisions expressed as relative standard deviations were less than 5.7 and 9.9%, respectively. The proposed method was successfully applied to the analysis of sildenafil and its five analogues in complex dietary supplements. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Determination of acetanilide herbicides in cereal crops using accelerated solvent extraction, solid-phase extraction and gas chromatography-electron capture detector.

    Science.gov (United States)

    Zhang, Yaping; Yang, Jun; Shi, Ronghua; Su, Qingde; Yao, Li; Li, Panpan

    2011-07-01

    A method was developed to determine eight acetanilide herbicides from cereal crops based on accelerated solvent extraction (ASE) and solid-phase extraction (SPE) followed by gas chromatography-electron capture detector (GC-ECD) analysis. During the ASE process, the effect of four parameters (temperature, static time, static cycles and solvent) on the extraction efficiency was considered and compared with shake-flask extraction method. After extraction with ASE, four SPE tubes (graphitic carbon black/primary secondary amine (GCB/PSA), GCB, Florisil and alumina-N) were assayed for comparison to obtain the best clean-up efficiency. The results show that GCB/PSA cartridge gave the best recoveries and cleanest chromatograms. The analytical process was validated by the analysis of spiked blank samples. Performance characteristics such as linearity, limit of detection (LOD), limit of quantitation (LOQ), precision and recovery were studied. At 0.05 mg/kg spiked level, recoveries and precision values for rice, wheat and maize were 82.3-115.8 and 1.1-13.6%, respectively. For all the herbicides, LOD and LOQ ranged from 0.8 to 1.7 μg/kg and from 2.4 to 5.3 μg/kg, respectively. The proposed analytical methodology was applied for the analysis of the targets in samples; only three herbicides, propyzamid, metolachlor and diflufenican, were detected in two samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Liquid-phase extraction coupled with metal-organic frameworks-based dispersive solid phase extraction of herbicides in peanuts.

    Science.gov (United States)

    Li, Na; Wang, Zhibing; Zhang, Liyuan; Nian, Li; Lei, Lei; Yang, Xiao; Zhang, Hanqi; Yu, Aimin

    2014-10-01

    Liquid-phase extraction coupled with metal-organic frameworks-based dispersive solid phase extraction was developed and applied to the extraction of pesticides in high fatty matrices. The herbicides were ultrasonically extracted from peanut using ethyl acetate as extraction solvent. The separation of the analytes from a large amount of co-extractive fat was achieved by dispersive solid-phase extraction using MIL-101(Cr) as sorbent. In this step, the analytes were adsorbed on MIL-101(Cr) and the fat remained in bulk. The herbicides were separated and determined by high-performance liquid chromatography. The experimental parameters, including type and volume of extraction solvent, ultrasonication time, volume of hexane and eluting solvent, amount of MIL-101(Cr) and dispersive solid phase extraction time, were optimized. The limits of detection for herbicides range from 0.98 to 1.9 μg/kg. The recoveries of the herbicides are in the range of 89.5-102.7% and relative standard deviations are equal or lower than 7.0%. The proposed method is simple, effective and suitable for treatment of the samples containing high content of fat. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Speciation analysis of tellurium by solid-phase extraction in the presence of ammonium pyrrolidine dithiocarbamate and inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Chunhai; Cai, Qiantao; Guo, Zhong-Xian; Yang, Zhaoguang [Centre for Advanced Water Technology, Innovation Centre (NTU), Singapore (Singapore); Khoo, Soo Beng [Department of Chemistry, National University of Singapore (Singapore)

    2003-05-01

    Under acidic conditions tellurium(IV) formed a complex with ammonium pyrrolidine dithiocarbamate (APDC). The tellurium(IV) complex was completely retained on a non-polar Isolute silica-based octadecyl (C{sub 18}) sorbent-containing solid-phase extraction (SPE) cartridge, while the uncomplexed Te(VI) passed through the cartridge and remained as a free species in the solution. Only partial Te(IV) was retained on the SPE cartridge for samples without addition of APDC. On the basis of different retention behaviours of the complexed Te(IV) and uncomplexed Te(VI), a simple and highly sensitive method is proposed for the determination of total tellurium and Te(VI) by SPE separation and inductively coupled plasma mass spectrometry (ICP-MS) detection. The Te(IV) concentration was calculated as the difference between total tellurium and Te(VI) concentrations. The detection limit (3{sigma}) is 3 ng L{sup -1} tellurium. Factors affecting the separation and detection of tellurium species were investigated. Coexisting ions did not show significant interferences with the Te(IV)-APDC complex retention and the subsequent ICP-MS detection of Te. The method has been successfully applied to the tellurium speciation analysis in waters with spiked recoveries for Te(IV) and Te(VI) of 86.0-108% and 87.1-97.4%, respectively. (orig.)

  8. Molecular imprinting solid phase extraction for selective detection of methidathion in olive oil.

    Science.gov (United States)

    Bakas, Idriss; Oujji, Najwa Ben; Moczko, Ewa; Istamboulie, Georges; Piletsky, Sergey; Piletska, Elena; Ait-Ichou, Ihya; Ait-Addi, Elhabib; Noguer, Thierry; Rouillon, Régis

    2012-07-13

    A specific adsorbent for extraction of methidathion from olive oil was developed. The design of the molecularly imprinted polymer (MIP) was based on the results of the computational screening of the library of polymerisable functional monomers. MIP was prepared by thermal polymerisation using N,N'-methylene bisacrylamide (MBAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The polymers based on the itaconic acid (IA), methacrylic acid (MAA) and 2-(trifluoromethyl)acryl acid (TFMAA) functional monomers and one control polymer which was made without functional monomers with cross-linker EGDMA were also synthesised and tested. The performance of each polymer was compared using corresponding imprinting factor. As it was predicted by molecular modelling the best results were obtained for the MIP prepared with MBAA. The obtained MIP was optimised in solid-phase extraction coupled with high performance liquid chromatography (MISPE-HPLC-UV) and tested for the rapid screening of methidathion in olive oil. The proposed method allowed the efficient extraction of methidathion for concentrations ranging from 0.1 to 9 mg L(-1) (r(2)=0.996). The limits of detection (LOD) and quantification (LOQ) in olive oil were 0.02 mg L(-1) and 0.1 mg L(-1), respectively. MIPs extraction was much more effective than traditional C18 reverse-phase solid phase extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Zinc oxide crystal whiskers as a novel sorbent for solid-phase extraction of flavonoids.

    Science.gov (United States)

    Wang, Licheng; Shangguan, Yangnan; Hou, Xiudan; Jia, Yong; Liu, Shujuan; Sun, Yingxin; Guo, Yong

    2017-08-15

    As a novel solid-phase extraction material, zinc oxide crystal whiskers were used to extract flavonoid compounds and showed good extraction abilities. X-ray diffraction, scanning electron microscopy with energy dispersive X-ray spectroscopy and surface area/pore volume characterized the sorbent. The zinc oxide was packed into a solid-phase extraction micro-column and its extraction ability was evaluated by four model flavonoid compounds. The sample loading and elution parameters were optimized and the zinc oxide based analytical method for flavonoids was established. It showed that the method has wide linearities from 1 to 150μg/L and low limits of detection at 0.25μg/L. The relative standard deviations of a single column repeatability and column to column reproducibility were less than 6.8% and 10.6%. Several real samples were analyzed by the established method and satisfactory results were obtained. The interactions between flavonoids and zinc oxide were calculated and proved to be from the Van der Waals' forces between the 4p and 5d orbitals from zinc atom and the neighboring π orbitals from flavonoid phenyl groups. Moreover, the zinc oxide crystal whiskers showed good stability and could be reused more than 50 times under the operation conditions. This work proves that the zinc oxide crystal whiskers are a good candidate for flavonoids enrichment. Copyright © 2017. Published by Elsevier B.V.

  10. Quantification of VX Nerve Agent in Various Food Matrices by Solid-Phase Extraction Ultra-Performance Liquid ChromatographyTime-of-Flight Mass Spectrometry

    Science.gov (United States)

    2016-04-01

    QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID - PHASE EXTRACTION ULTRA-PERFORMANCE...TITLE AND SUBTITLE Quantification of VX Nerve Agent in Various Food Matrices by Solid - Phase Extraction Ultra-Performance Liquid Chromatography...QUANTIFICATION OF VX NERVE AGENT IN VARIOUS FOOD MATRICES BY SOLID - PHASE EXTRACTION ULTRA-PERFORMANCE LIQUID CHROMATOGRAPHY–TIME-OF-FLIGHT MASS

  11. [Determination of deoxynivalenol in grain and its products by solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Huang, Juan; Chen, Guosong; Zhang, Xiaoyan; Shen, Chongyu; Lü, Chen; Wu, Bin; Liu, Yan; Chen, Huilan; Ding, Tao

    2012-11-01

    A method was established for the determination of deoxynivalenol (vomitoxin) in grain and its products based on solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was firstly extracted by acetonitrile-water (84:16, v/v). The extract was then cleaned-up by an HLB solid phase extraction cartridge. The separation was carried out on a Phenomenex Kinetex C18 column (100 mm x4. 6 mm, 2.6 microm) with a gradient elution using 0.3% per hundred ammonia solution-acetonitrile as mobile phases. The analysis of deoxynivalenol was performed under electrospray negative ionization mode. The limit of detection (LOD, S/N= 3) and the limit of quantification (LOQ, S/N = 10) were 20 microg/kg and 50 microg/kg, respectively. A good linearity (r > 0.99) was achieved for the target compound over the range of 20-1000 pg/L. The recoveries at the three spiked levels (50, 100, 500 microg/kg) in the blank matrices such as flour, barley, soybean, rice, cornmeal, cassava and wheat, were varied from 75.6% to 111.0% with the relative standard deviations no more than 13. 0%. The method is accurate, efficient, sensitive and practical. The cost of pretreatment is obviously reduced by replacing immunoaffinity columns and Mycosep columns with HLB columns which have the same purification effect.

  12. Poly(Dimethylsiloxane)-Poly(Vinyl Alcohol) Coated Solid Phase Micro extraction Fiber for Chloropyrifos Analysis

    International Nuclear Information System (INIS)

    Wan Aini Wan Ibrahim; Nor Fairul Zukry Ahmad Rasdy; Norfazilah Muhamad

    2016-01-01

    Traditional liquid - liquid extraction of pesticides consumes large volumes of organic solvent which are hazardous to the operator and is not environment friendly. Solid phase micro extraction (SPME) is a solvent less extraction method which is safer to the operator and is environmental friendly. A sol-gel hybrid fibre coating material, poly(dimethylsiloxane)-poly(vinyl alcohol) (PDMS-PVA) was synthesized and used in head space solid phase micro extraction (HS-SPME) of chloropyrifos. The thickness of the synthesised PDMS-PVA fiber coating was 13.5 μm and it is thermally stable up to 400 degree Celsius. The PDMS-PVA sol-gel hybrid fiber was also stable to two organic solvents tested; acetonitrile and dichloromethane (1 hour dipping) and showed no significant changes in extraction performance for chloropyrifos. Extracted chloropyrifos was analysed using gas chromatography electron capture detector (GC-ECD). Optimum SPME parameters affecting the PDMS-PVA HS-SPME performance namely extraction time (15 min), extraction temperature (50 degree Celsius), desorption time (5 min), desorption temperature (260 degree Celsius) and stirring rate (120 rpm) were used for extraction. It was found that HSSPME using PDMS-PVA sol-gel fiber gave significantly better extraction performance of chloropyrifos compared to commercial 100 μm PDMS fiber. The PDMS-PVA fiber showed excellent operational performances such as temperature stability (up to 380 degree Celsius), coating lifetime (up to 170 times use) and organic solvent stability. The PDMS-PVA-HS-SPME method showed excellent recovery for chloropyrifos from tomatoes (98.0 %, 5.9 % RSD) at 0.01 μg/ g spiked level (5 times lower than maximum residue limit set by European Union). (author)

  13. Solid phase extraction of uranium from phosphoric acid. Kinetic and thermodynamic study

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Magied, Ahmed Fawzy [Nuclear Materials Authority, Cairo (Egypt); Stockholm Univ. (Sweden). Dept. of Organic Chemistry

    2017-07-01

    There is a high interest to develop suitable solid phase extractants for uranium separation from aqueous solutions in order to reduce cost and enhance the efficiency. This paper describes solid phase extraction of uranium(VI) from aqueous phosphoric acid solution using MCM-41 based D2HEPA-TOPO organophosphorous extractants. The mixture of D2HEPA (di-2-ethyl-hexylphosphoric acid) and TOPO (tri-n-octylphosphine oxide) was impregnated into the pores of MCM-41 and the synthesized sorbent was fully characterized. The influences of different factors such as synergistic mixture ratio, phosphoric acid concentration, mixing time and temperature were investigated. The results showed that 90% of uranium(VI) extraction can be achieved within 5 min, using D2HEPA-TOPO rate at MCM-41 (mass ratio 2:1 w/w) from 1 M phosphoric acid containing 64 ppm of uranium at room temperature. High adsorption capacity of uranium(VI) have been achieved at the mentioned conditions. The rate constant for the chemical adsorption of uranium(VI) was 0.988 g mg{sup -1} min{sup -1} calculated by the pseudo-second order rate equation. The obtained thermodynamics parameters showed that uranium(VI) adsorption from H{sub 3}PO{sub 4} is an exothermic and spontaneous process.

  14. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  15. Halogen bonding: A new retention mechanism for the solid phase extraction of perfluorinated iodoalkanes

    International Nuclear Information System (INIS)

    Yan Xiaoqing; Shen Qianjin; Zhao Xiaoran; Gao Haiyue; Pang Xue; Jin Weijun

    2012-01-01

    Highlights: ► Halogen bonding (XB) is firstly utilised in solid phase extraction. ► The perfluorinated iodine alkanes can be extracted by C-I⋯Cl − halogen bonding. ► The C-I⋯Cl − halogen bond is well characterised by spectroscopy methods. ► The analytes with strong halogen-bonding abilities can be selectively extracted. - Abstract: For the first time, halogen-bonding interaction is utilised in the solid phase extraction of perfluorinated iodoalkane (PFI). Nine PFIs, as model analytes, were tested, and analyses by UV, 19 F NMR and Raman spectroscopies demonstrate that the PFIs are extracted by a strong anion exchange (SAX) sorbent from n-hexane due to the C-I⋯Cl − halogen-bonding interactions. The results also show that the adsorptivities of SAX for the diiodoperfluoro-alkanes (diiodo-PFIs) were much stronger than those for the perfluoroalkyl iodides (monoiodo-PFIs). Specifically, the recoveries for 1,6-diiodoperfluorohexane and 1,8-diiodoperfluorooctane were higher than 80% when 100 mL of sample spiked with a 5 ng mL −1 analyte mixture was extracted. Interestingly, SAX had no adsorption for hexafluorobenzene at all, which is known to be unable to form a halogen bond with Cl − . The analytical performance of the halogen bond-based SPE-GC–MS method for the diiodo-PFIs was also examined in soil samples. The sorbent SAX enabled the selective extraction of four diiodo-PFIs successfully from soil samples. The recoveries of the diiodo-PFIs extracted from 5 g soil sample at the 100 ng g −1 spike level were in the range of 73.2–93.8% except 26.8% for 1,2-diiodoperfluoroethane. The limit of detection varied from 0.02 to 0.04 ng g −1 in soil samples. Overall, this work reveals the great application potential of halogen bonding in the field of solid phase extraction to selectively extract compounds with strong halogen-bonding abilities.

  16. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD) and Dispersive Solid Phase Extraction (d-SPE) of Plant Samples

    Science.gov (United States)

    Sowa, Ireneusz; Wójciak-Kosior, Magdalena; Strzemski, Maciej; Sawicki, Jan; Staniak, Michał; Dresler, Sławomir; Szwerc, Wojciech; Mołdoch, Jarosław; Latalski, Michał

    2018-01-01

    Polyaniline (PANI) is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME). In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI) was used for dispersive solid phase extraction (d-SPE) and matrix solid–phase extraction (MSPD). The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD) quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples. PMID:29565297

  17. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD and Dispersive Solid Phase Extraction (d-SPE of Plant Samples

    Directory of Open Access Journals (Sweden)

    Ireneusz Sowa

    2018-03-01

    Full Text Available Polyaniline (PANI is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME. In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI was used for dispersive solid phase extraction (d-SPE and matrix solid–phase extraction (MSPD. The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples.

  18. Polymeric Sorbent with Controlled Surface Polarity: An Alternate for Solid-Phase Extraction of Nerve Agents and Their Markers from Organic Matrix.

    Science.gov (United States)

    Roy, Kanchan Sinha; Purohit, Ajay Kumar; Chandra, Buddhadeb; Goud, D Raghavender; Pardasani, Deepak; Dubey, Devendra Kumar

    2018-06-05

    Extraction and identification of lethal nerve agents and their markers in complex organic background have a prime importance from the forensic and verification viewpoint of the Chemical Weapons Convention (CWC). Liquid-liquid extraction with acetonitrile and commercially available solid phase silica cartridges are extensively used for this purpose. Silica cartridges exhibit limited applicability for relatively polar analytes, and acetonitrile extraction shows limited efficacy toward relatively nonpolar analytes. The present study describes the synthesis of polymeric sorbents with tunable surface polarity, their application as a solid-phase extraction (SPE) material against nerve agents and their polar as well as nonpolar markers from nonpolar organic matrices. In comparison with the acetonitrile extraction and commercial silica cartridges, the new sorbent showed better extraction efficiency toward analytes of varying polarity. The extraction parameters were optimized for the proposed method, which included ethyl acetate as an extraction solvent and n-hexane as a washing solvent. Under optimized conditions, method linearity ranged from 0.10 to 10 μg mL -1 ( r 2 = 0.9327-0.9988) for organophosphorus esters and 0.05-20 μg mL -1 ( r 2 = 0.9976-0.9991) for nerve agents. Limits of detection (S:N = 3:1) in the SIM mode were found in the range of 0.03-0.075 μg mL -1 for organophosphorus esters and 0.015-0.025 μg mL -1 for nerve agents. Limits of quantification (S:N = 10:1) were found in the range of 0.100-0.25 μg mL -1 for organophosphorus esters and 0.05-0.100 μg mL -1 for nerve agents in the SIM mode. The recoveries of the nerve agents and their markers ranged from 90.0 to 98.0% and 75.0 to 95.0% respectively. The repeatability and reproducibility (with relative standard deviations (RSDs) %) for organophosphorus esters were found in the range of 1.35-8.61% and 2.30-9.25% respectively. For nerve agents, the repeatability range from 1.00 to 7.75% and reproducibility

  19. VOLATILE COMPOUNDS OF LITHRAEA CAUSTICA (LITRE) DETERMINATED BY SOLID PHASE MICRO-EXTRACTION (SPME)

    OpenAIRE

    GARBARINO, JUAN A; SALVATORE, GIUSEPPE; PIVANOVO, MARISA; CHAMY, MARÍA CRISTINA; NICOLETTI, MARCELLO; DE IOANNES, ALFREDO

    2002-01-01

    The head space of the aerial parts of Lithraea caustica was analyzed by Solid Phase Micro-Extraction (SPME) technique, obtaining as main volatile compounds the monoterpenes, myrcene, a -pinene, , p-cymene and limonene, as well as the sesquiterpene caryophylene. De las partes áereas de Lithraea caustica y usando la técnica de Micro-Extracción en Fase Sólida (MEFS), fueron identificados y cuantificados los principales compuestos volátiles: los monoterpenos, mirceno, a -pineno, p-cimeno y lim...

  20. Development of magnetic micro-solid phase extraction for analysis of phthalate esters in packaged food.

    Science.gov (United States)

    Makkliang, Fonthip; Kanatharana, Proespichaya; Thavarungkul, Panote; Thammakhet, Chongdee

    2015-01-01

    A novel, simple and low cost magnetic multi-walled carbon nanotubes-poly (vinyl alcohol) cryogel-micro-solid phase extraction (magnetic-MWCNTs-PVA cryogel-μ-SPE) sorbent was synthesized by incorporating magnetic particles and MWCNTs into a PVA cryogel. The magnetic-MWCNTs-PVA cryogel-μ-SPE sorbent developed, with a large surface area and macro-porous structure, provided good sorbent-to-sorbent reproducibility (%RSDclear chicken soup samples in the range 0.02-0.07 μg mL(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Development of andrographolide molecularly imprinted polymer for solid-phase extraction

    Science.gov (United States)

    Yin, Xiaoying; Liu, Qingshan; Jiang, Yifan; Luo, Yongming

    2011-06-01

    A method employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE) to pretreat samples was developed. The polymers were prepared by precipitation polymerization with andrographolide as template molecule. The structure of MIP was characterized and its static adsorption capacity was measured by the Scatchard equation. In comparison with C 18-SPE and non-imprinted polymer (NIP) SPE column, MIP-SPE column displays high selectivity and good affinity for andrographolide and dehydroandrographolide for extract of herb Andrographis paniculata ( Burm.f.) Nees (APN). MIP-SPE column capacity was 11.9 ± 0.6 μmol/g and 12.1 ± 0.5 μmol/g for andrographolide and dehydroandrographolide, respectively and was 2-3 times higher than that of other two columns. The precision and accuracy of the method developed were satisfactory with recoveries between 96.4% and 103.8% (RSD 3.1-4.3%, n = 5) and 96.0% and 104.2% (RSD 2.9-3.7%, n = 5) for andrographolide and dehydroandrographolide, respectively. Various real samples were employed to confirm the feasibility of method. This developed method demonstrates the potential of molecularly imprinted solid phase extraction for rapid, selective, and effective sample pretreatment.

  2. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  3. Use of itaconic acid-based polymers for solid-phase extraction of deoxynivalenol and application to pasta analysis.

    Science.gov (United States)

    Pascale, Michelangelo; De Girolamo, Annalisa; Visconti, Angelo; Magan, Naresh; Chianella, Iva; Piletska, Elena V; Piletsky, Sergey A

    2008-02-25

    Molecular modelling and computational design were used to identify itaconic acid (IA) as a functional monomer with high affinity towards deoxynivalenol (DON), a Fusarium-toxin frequently occurring in cereals. IA-based polymers were photochemically synthesised in dimethyl formamide (porogen) using ethylenglycol dimethacrylate as cross-linker and 1,1'-azo-bis(cyclohexane carbonitrile) as initiator, and the relevant binding interactions with DON in solvents with different polarity were investigated. The performances of the non-imprinted IA-based polymer (blank polymer, BP) and the corresponding molecularly imprinted polymer (MIP) were compared using DON as a template. Both BP and MIP were able to bind about 90% DON either in toluene, water or water containing 5% polyethylene glycol. Non-imprinted polymers with different molar ratios of IA to cross-linker were evaluated as adsorbents for solid-phase extraction (SPE) clean-up and pre-concentration of DON from wheat and pasta samples prior to HPLC analysis. Samples were extracted with PBS/0.1M EDTA solution and cleaned up through a cartridge containing blank IA-based polymer. The column was washed with PBS (pH 9.2) and the toxin was eluted with methanol and quantified by reversed-phase HPLC with UV detector (lambda=220nm), using methanol:water:acetic acid (15:85:0.1, v/v/v) as the mobile phase. Effective removal of matrix interferences was observed only for pasta with DON recoveries higher than 70% (RSD<7%, n=3) at levels close to or higher than EU regulatory limit.

  4. Combined solid-phase extraction and gas chromatography-mass spectrometry used for determination of chloropropanols in water.

    Science.gov (United States)

    González, Paula; Racamonde, Inés; Carro, Antonia M; Lorenzo, Rosa A

    2011-10-01

    A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. An interior needle electropolymerized pyrrole-based coating for headspace solid-phase dynamic extraction

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Habib [Department of Chemistry, Sharif University of Technology, Azadi Av., P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)], E-mail: bagheri@sharif.edu; Babanezhad, Esmaeil; Khalilian, Faezeh [Department of Chemistry, Sharif University of Technology, Azadi Av., P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)

    2009-02-23

    A headspace solid-phase dynamic extraction (HS-SPDE) technique was developed by the use of polypyrrole (PPy) sorbent, electropolymerized inside the surface of a needle, as a possible alternative to solid-phase microextraction (SPME). Thermal desorption was subsequently, employed to transfer the extracted analytes into the injection port of a gas chromatography-mass spectrometry (GC-MS). The PPy sorbent including polypyrrole-dodecyl sulfate (PPy-DS) was deposited on the interior surface of a stainless steel needle from the corresponding aqueous electrolyte by applying a constant deposition potential. The homogeneity and the porous surface structure of the coating were examined using the scanning electron microscopy (SEM). The developed method was applied to the trace level extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample. In order to enhance the extraction efficiency and increase the partition coefficient of analytes, the stainless steel needle was cooled at 5 deg. C, while the sample solution was kept at 80 deg. C. Optimization of influential experimental conditions including the voltage of power supply, the time of PPy electrodeposition, the extraction temperature, the ionic strength and the extraction time were also investigated. The detection limits of the method under optimized conditions were in the range of 0.002-0.01 ng mL{sup -1}. The relative standard deviations (R.S.D.) at a concentration level of 0.1 ng mL{sup -1} were obtained between 7.54 and 11.4% (n = 6). The calibration curves of PAHs showed linearity in the range of 0.01-10 ng mL{sup -1}. The proposed method was successfully applied to the extraction of some selected PAHs from real-life water samples and the relative recoveries were higher than 90% for all the analytes.

  6. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    Science.gov (United States)

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and

  7. Rapid determination of ions by combined solid-phase extraction--diffuse reflectance spectroscopy

    Science.gov (United States)

    Fritz, James S.; Arena, Matteo P.; Steiner, Steven A.; Porter, Marc D.

    2003-01-01

    We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.

  8. Optimization of Solid Phase Micro-Extraction (SPME for Monitoring Occupational Exposure to Ethyl Benzene

    Directory of Open Access Journals (Sweden)

    H. Heidari

    2009-08-01

    Full Text Available AbstractBackground and Objectives: Analytical methods for volatile organic compounds (VOCs in different samples need extraction of compounds, by applying hazardous solvents. Solid phase micro-extraction (SPME is a solvent-free equilibrium extraction method, in which proper calibration can allow quantitative determinations of VOCs at a very good sensitivity without the use of any organic solvent. VOCs are generally present in urine only at trace levels, therefore, a sensitive procedure is needed for their trace determinations. Throughout this study, headspace solid phase micro-extraction (HS-SPME was followed by GC-FID for ethyl benzene in spiked urine was optimized.Methods: In this study, the parameters influencing SPME and gas chromatography of ethyl benzene, including extraction time, temperature, desorption temperature, desorption time, salt addition, sample pH, sample volume and sample agitation were investigated. Results: Extraction procedure was performed at 30°C for 6 min, using 0.2 gml-1 of NaCl in the sample solution. The sample volume and sample pH were optimized at 5 ml and 7 (neutral pH, respectively. Desorption of the ethyl benzene was carried out for 60 sec. at 250°C. The method was also validated with three different spiked urine samples and illustrated an appropriate reproducibility over six consecutive days as well as six within-day experiments. During this investigation, parameters of accuracy, linearity, and detection limits of the procedure were also evaluated.Conclusion: The developed method of HS- SPME-GC-FID proved to be a simple, convenient, and practical procedure, and was successfully used for measuring of ethyl benzene in spiked urine.

  9. Immobilized humic substances and immobilized aggregates of humic substances as sorbent for solid phase extraction.

    Science.gov (United States)

    Erny, Guillaume L; Gonçalves, Bruna M; Esteves, Valdemar I

    2013-09-06

    In this work, humic substances (HS) immobilized, as a thin layer or as aggregates, on silica gel were tested as material for solid phase extraction. Some triazines (simazine, atrazine, therbutylazine, atrazine-desethyl-desisopropyl-2-hydroxy, ametryn and terbutryn), have been selected as test analytes due to their environmental importance and to span a large range of solubility and octanol/water partition coefficient (logP). The sorbent was obtained immobilizing a thin layer of HS via physisorption on a pre-coated silica gel with a cationic polymer (polybrene). While the sorbent could be used as it is, it was demonstrated that additional HS could be immobilized, via weak interactions, to form stable humic aggregates. However, while a higher quantity of HS could be immobilized, no significant differences were observed in the sorption parameters. This sorbent have been tested for solid phase extraction to concentrate triazines from aqueous matrixes. The sorbent demonstrated performances equivalent to commercial alternatives as a concentration factor between 50 and 200, depending on the type of triazines, was obtained. Moreover the low cost and the high flow rate of sample through the column allowed using high quantity of sorbent. The analytical procedure was tested with different matrixes including tap water, river water and estuarine water. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Amino-modified diamond as a durable stationary phase for solid-phase extraction.

    Science.gov (United States)

    Saini, Gaurav; Yang, Li; Lee, Milton L; Dadson, Andrew; Vail, Michael A; Linford, Matthew R

    2008-08-15

    We report the formation of a highly stable amino stationary phase on diamond and demonstrate its use in solid-phase extraction (SPE). This process consists of spontaneous and self-limiting adsorption of polyallylamine (PAAm) from aqueous solution onto oxidized diamond. Thermal curing under reduced pressure or chemical cross-linking with a diepoxide was shown to fix the polymer to the particles. The resulting adsorbents are stable under even extreme pH conditions (from at least pH 0-14) and significantly more stable than a commercially available amino SPE adsorbent. Coated diamond particles were characterized by X-ray photoelectron spectroscopy (XPS) and diffuse reflectance Fourier transform-infrared spectroscopy (DRIFT). Model silicon surfaces were characterized by spectroscopic ellipsometry and wetting. Solid-phase extraction was demonstrated using cholesterol, hexadecanedioic acid, and palmitoyloleoylphosphatidylcholine as analytes, and these results were compared to those obtained with commercially available materials. Breakthrough curves indicate that, as expected, porous diamond particles have higher analyte capacity than nonporous solid particles.

  11. Study on Solid Phase Extraction and Spectrophotometric Determination of Nickel in Waters and Biological Samples

    International Nuclear Information System (INIS)

    Hu, Qiufen; Yang, Guangyu; Huang, Zhangjie; Yin, Jiayuan

    2004-01-01

    A sensitive, selective and rapid method for the determination of nickel based on the rapid reaction of nickel(II) with QADMAA and the solid phase extraction of the Ni(II)-QADMAA chelate with C 18 membrane disks has been developed. In the presence of pH 6.0 buffer solution and sodium dodecyl sulfonate (SDS) medium, QADMAA reacts with nickel to form a violet complex of a molar ratio of 1 : 2 (nickel to QADMAA). This chelate was enriched by solid phase extraction with C 18 membrane disks. An enrichment factor of 50 was obtained by elution of the chelates form the disks with the minimal amount of isopentyl alcohol. The molar absorptivity of the chelate was 1.32 x 10 5 L mol -1 cm -1 at 590 nm in the measured solution. Beer's law was obeyed in the range of 0.01-0.6 μg/mL. This method was applied to the determination of nickel in water and biological samples with good results

  12. Determination of submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples by solid-phase extraction and liquid chromatography

    Science.gov (United States)

    Burkhardt, M.R.; Soliven, P.P.; Werner, S.L.; Vaught, D.G.

    1999-01-01

    A method for determining submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples has been developed. Caffeine is extracted from a 1 L water sample with a 0.5 g graphitized carbon-based solid-phase cartridge, eluted with methylene chloride-methanol (80 + 20, v/v), and analyzed by liquid chromatography with photodiode-array detection. The single-operator method detection limit for organic-free water samples was 0.02 ??g/L. Mean recoveries and relative standard deviations were 93 ?? 13% for organicfree water samples fortified at 0.04 ??g/L and 84 ?? 4% for laboratory reagent spikes fortified at 0.5 ??g/L. Environmental concentrations of caffeine ranged from 0.003 to 1.44 ??g/L in surface water samples and from 0.01 to 0.08 ??g/L in groundwater samples.

  13. Gas chromatographic-mass spectrometric determination of hydrophilic compounds in environmental water by solid-phase extraction with activated carbon fiber felt.

    Science.gov (United States)

    Kawata, K; Ibaraki, T; Tanabe, A; Yagoh, H; Shinoda, A; Suzuki, H; Yasuhara, A

    2001-03-09

    Simple gas chromatographic-mass spectrometric determination of hydrophilic organic compounds in environmental water was developed. A cartridge containing activated carbon fiber felt was made by way of trial and was evaluated for solid-phase extraction of the compounds in water. The hydrophilic compounds investigated were acrylamide, N,N-dimethylacetamide, N,N-dimethylformamide, 1,4-dioxane, furfural, furfuryl alcohol, N-nitrosodiethylamine and N-nitrosodimethylamine. Overall recoveries were good (80-100%) from groundwater and river water. The relative standard deviations ranged from 4.5 to 16% for the target compounds. The minimum detectable concentrations were 0.02 to 0.03 microg/l. This method was successfully applied to several river water samples.

  14. Sensitivity enhancement for nitrophenols using cationic surfactant-modified activated carbon for solid-phase extraction surface-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Chen, Y C; Tsai, M F

    2000-01-01

    Previous work has demonstrated that a combination of solid-phase extraction with surface-assisted laser desorption/ionization (SPE-SALDI) mass spectrometry can be applied to the determination of trace nitrophenols in water. An improved method to lower the detection limit of this hyphenated technique is described in this present study. Activated carbon powder is used as both the SPE adsorbent and the SALDI solid in the analysis by SPE-SALDI. The surface of the activated carbon is modified by passing an aqueous solution of a cationic surfactant through the SPE cartridge. The results demonstrate that the sensitivity for nitrophenols in the analysis by SPE-SALDI can be improved by using cationic surfactants to modify the surface of the activated carbon. The detection limit for nitrophenols is about 25 ppt based on a signal-to-noise ratio of 3 by sampling from 100 mL of solution. Copyright 2000 John Wiley & Sons, Ltd.

  15. Simultaneous Screening and Quantification of 29 Drugs of Abuse in Oral Fluid by Solid-Phase Extraction and Ultraperformance LC-MS/MS

    DEFF Research Database (Denmark)

    Linnet, Kristian; Badawi, Nora; Simonsen, Kirsten W.

    2009-01-01

    performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and {Delta}-9-tetrahydrocannabinol. Method: Solid-phase extraction was performed with a Gilson ASPEC XL......4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters...... of amphetamine, cocaine, codeine, {Delta}-9-tetrahydrocannabinol, tramadol, and zopiclone. Conclusions: The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including {Delta}-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult...

  16. Evaluation of single-walled carbon nanohorns as sorbent in dispersive micro solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Soto, Juan Manuel; Cardenas, Soledad [Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building, Campus de Rabanales, University of Cordoba, 14071 Cordoba (Spain); Valcarcel, Miguel, E-mail: qa1meobj@uco.es [Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building, Campus de Rabanales, University of Cordoba, 14071 Cordoba (Spain)

    2012-02-10

    Highlights: Black-Right-Pointing-Pointer The potential of single walled carbon nanohorns in dispersive solid phase microextraction has been evaluated. Black-Right-Pointing-Pointer The method was characterized for the extraction of PAHs from waters. Black-Right-Pointing-Pointer Single walled carbon nanohorns were better extractant than carbon nanotubes and carbon nanocones. Black-Right-Pointing-Pointer The limits of detection were adequate for the target analytes in environmental waters. - Abstract: A new dispersive micro solid-phase extraction method which uses single-walled carbon nanohorns (SWNHs) as sorbent is proposed. The procedure combines the excellent sorbent properties of the nanoparticles with the efficiency of the dispersion of the material in the sample matrix. Under these conditions, the interaction with the analytes is maximized. The determination of polycyclic aromatic hydrocarbons was selected as model analytical problem. Two dispersion strategies were evaluated, being the functionalization via microwave irradiation better than the use of a surfactant. The extraction was accomplished by adding 1 mL of oxidized SWHNs (o-SWNHs) dispersion to 10 mL of water sample. After extraction, the mixture was passed through a disposable Nylon filter were the nanoparticles enriched with the PAHs were retained. The elution was carried out with 100 {mu}L of hexane. The limits of detection achieved were between 30 and 60 ng L{sup -1} with a precision (as repeatability) better than 12.5%. The recoveries obtained for the analytes in three different water samples were acceptable in all instances. The performance of o-SWNHs was favourably compared with that provided by carboxylated single-walled carbon nanotubes and thermally treated carbon nanocones.

  17. Automated solid-phase extraction of phenolic acids using layered double hydroxide-alumina-polymer disks.

    Science.gov (United States)

    Ghani, Milad; Palomino Cabello, Carlos; Saraji, Mohammad; Manuel Estela, Jose; Cerdà, Víctor; Turnes Palomino, Gemma; Maya, Fernando

    2018-01-26

    The application of layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks for solid-phase extraction is reported for the first time. Al 2 O 3 is embedded in a polymer matrix followed by an in situ metal-exchange process to obtain a layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disk with excellent flow-through properties. The extraction performance of the prepared disks is evaluated as a proof of concept for the automated extraction using sequential injection analysis of organic acids (p-hydroxybenzoic acid, 3,4-dihydroxybenzoic acid, gallic acid) following an anion-exchange mechanism. After the solid-phase extraction, phenolic acids were quantified by reversed-phase high-performance liquid chromatography with diode-array detection using a core-shell silica-C18 stationary phase and isocratic elution (acetonitrile/0.5% acetic acid in pure water, 5:95, v/v). High sensitivity and reproducibility were obtained with limits of detection in the range of 0.12-0.25 μg/L (sample volume, 4 mL), and relative standard deviations between 2.9 and 3.4% (10 μg/L, n = 6). Enrichment factors of 34-39 were obtained. Layered double hydroxide-Al 2 O 3 -polymer mixed-matrix disks had an average lifetime of 50 extractions. Analyte recoveries ranged from 93 to 96% for grape juice and nonalcoholic beer samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Liquid chromatography tandem mass spectrometry method using solid-phase extraction and bead-beating-assisted matrix solid-phase dispersion to quantify the fungicide tebuconazole in controlled frog exposure study: analysis of water and animal tissue

    DEFF Research Database (Denmark)

    Hansen, Martin; Poulsen, Rikke; Luong, Xuan

    2014-01-01

    and on tissue from exposed and non-exposed adult X. laevis. Using solid-phase extraction (SPE), the analytical method allows for quantification of tebuconazole at concentrations as low as 3.89 pg mL(-1) in 10 mL water samples. Using bead-beating-assisted matrix solid-phase dispersion (MSPD), it was possible...

  19. Tandem solid-phase extraction followed by HPLC-ESI/QTOF/MS/MS for rapid screening and structural identification of trace diterpenoids in flowers of Rhododendron molle.

    Science.gov (United States)

    Zou, Hong-Yan; Luo, Jun; Xu, De-Ran; Kong, Ling-Yi

    2014-01-01

    'Naoyanghua', composed of the flowers of Rhododendron molle G. Don, is a traditional Chinese medicine that is widely known for its toxicity. Grayanane-type diterpenoids are the main active ingredients in R. molle, as well as possibly their toxicity: they are, however, difficult to isolate and analyse using common chromatographic methods, due to their small amounts and absence of conjugated groups, such as phenyl and α, β-unsaturated ketone. To establish a highly sensitive, selective and reliable method for the qualitative evaluation of trace diterpenoids in the flowers of R. molle by using tandem solid-phase extraction followed by high-performance liquid chromatography with electrospray ionisation quadrupole-time-of-flight mass spectrometry (HPLC-ESI/QTOF/MS/MS). Tandem solid phase extraction (SPE) was undertaken using a polyamide cartridge and a C18E cartridge in succession to enrich the trace diterpenoids. HPLC-ESI/QTOF/MS/MS was used to determine the fragmentation patterns of diterpenoids and to tentatively characterise their fragmentation pathways. HPLC-ESI/QTOF/MS/MS detected a total of 14 diterpenoids, eight of which were identified by comparison with literature sources and six based on fragmentation analysis. Among the latter six, rhodojaponin VI-3-glucoside was tentatively identified as a new diterpenoid glycoside and rhodojaponin VII, rhodojaponin IV and rhodojaponin I were reported from R. molle for the first time. By qualitative research of diterpenoids in this plant by HPLC-ESI/QTOF/MS/MS, a reliable methodology for the analysis of these active constituents of R. molle was established for the first time. Copyright © 2014 John Wiley & Sons, Ltd.

  20. [Determination of 23 antibiotics and 3 β-agonists in livestock drinking water by ultra performance liquid chromatography-tandem mass spectrometry coupled with solid-phase extraction].

    Science.gov (United States)

    Shi, Ao

    2016-02-01

    A method has been developed for the simultaneous determination of 23 antibiotics (four categories) and 3 β-agonists in livestock drinking water using solid-phase extraction and ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The samples were adjusted pH to 5. 0, added Na2EDTA, enriched and cleaned-up by an HLB solid-phase extraction cartridge. The target compounds were confirmed and quantified by UPLC-ESI MS/MS with external standard method for the anti- biotics and internal standard method for the β-agonists. The recoveries were assessed by using lab tap water as matrix. The average recoveries of the 23 antibiotics and the 3 β-agonists were in the range of 50. 7%-104. 6% and the relative standard deviations (RSDs) were 2. 6%-8. 8% (n= 3). Under the optimal conditions, the calibration curves of the 23 antibiotics and the 3 β-agonists showed good linearity with the correlation coefficients better than 0. 994. The limits of detection (LODs, S/N≥3) ranged from 0. 01-0. 20 ng/L. The developed method was applied to analyze the livestock drinking waters in 36 Beijing intensive livestock farms. The results showed that some antibiotics were detected.

  1. Multi-layer solid-phase extraction and evaporation-enrichment methods for polar organic chemicals from aqueous matrices.

    Science.gov (United States)

    Köke, Niklas; Zahn, Daniel; Knepper, Thomas P; Frömel, Tobias

    2018-03-01

    Analysis of polar organic chemicals in the aquatic environment is exacerbated by the lack of suitable and widely applicable enrichment methods. In this work, we assessed the suitability of a novel combination of well-known solid-phase extraction (SPE) materials in one cartridge as well as an evaporation method and for the enrichment of 26 polar model substances (predominantly log D evaporation method were investigated for the recovery and matrix effects of the model substances and analyzed with hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). In total, 65% of the model substances were amenable (> 10% recovery) to the mlSPE method with a mean recovery of 76% while 73% of the model substances were enriched with the evaporation method achieving a mean recovery of 78%. Target and non-target screening comparison of both methods with a frequently used reversed-phase SPE method utilizing "hydrophilic and lipophilic balanced" (HLB) material was performed. Target analysis showed that the mlSPE and evaporation method have pronounced advantages over the HLB method since the HLB material retained only 30% of the model substances. Non-target screening of a ground water sample with the investigated enrichment methods showed that the median retention time of all detected features on a HILIC system decreased in the order mlSPE (3641 features, median t R 9.7 min), evaporation (1391, 9.3 min), HLB (4414, 7.2 min), indicating a higher potential of the described methods to enrich polar analytes from water compared with HLB-SPE. Graphical abstract Schematic of the method evaluation (recovery and matrix effects) and method comparison (target and non-target analysis) of the two investigated enrichment methods for very polar chemicals in aqueousmatrices.

  2. Application of micro-solid-phase extraction for the on-site extraction of heterocyclic aromatic amines in seawater.

    Science.gov (United States)

    Basheer, Chanbasha

    2018-04-01

    An efficient on-site extraction technique to determine carcinogenic heterocyclic aromatic amines in seawater has been reported. A micro-solid-phase extraction device placed inside a portable battery-operated pump was used for the on-site extraction of seawater samples. Before on-site applications, parameters that influence the extraction efficiency (extraction time, type of sorbent materials, suitable desorption solvent, desorption time, and sample volume) were investigated and optimized in the laboratory. The developed method was then used for the on-site sampling of heterocyclic aromatic amines determination in seawater samples close to distillation plant. Once the on-site extraction completed, the small extraction device with the analytes was brought back to the laboratory for analysis using high-performance liquid chromatography with fluorescence detection. Based on the optimized conditions, the calibration curves were linear over the concentration range of 0.05-20 μg/L with correlation coefficients up to 0.996. The limits of detection were 0.004-0.026 μg/L, and the reproducibility values were between 1.3 and 7.5%. To evaluate the extraction efficiency, a comparison was made with conventional solid-phase extraction and it was applied to various fortified real seawater samples. The average relative recoveries obtained from the spiked seawater samples varied in the range 79.9-95.2%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Solid phase extraction of polychlorinated biphenyls from water containing humic substances

    Energy Technology Data Exchange (ETDEWEB)

    Bonifazi, P.; Pierini, E.; Bruner, F. [Centro di Studio per la Chimica dell`Ambiente e le Tecnologie Strumentali Avanzate dell` Universita degli Studi di Urbino, Ist. di Scienze Chimiche (Italy)

    1997-06-01

    A study was carried out of the recovery by solid phase extraction of the eleven most toxic polychlorinated biphenyls from water containing humic acids. Experiments were performed using water polluted with a humic acid (sodium salt) concentration of 9-18 mg L{sup -1}. The effect of humic acids on the recoveries was noticeable, especially where the more chlorinated congeners were concerned. The effect was also evident with river water containing naturally dissolved humic acids. A method for destroying humic acids prior to extraction was applied. The recoveries after the destruction of humic acids were in the range of 90%, even in the case of river water, demonstrating the applicability of the method to real samples. (orig.)

  4. Optimization of hydrophilic interaction liquid chromatography/mass spectrometry and development of solid-phase extraction for the determination of paralytic shellfish poisoning toxins.

    Science.gov (United States)

    Turrell, Elizabeth; Stobo, Lesley; Lacaze, Jean-Pierre; Piletsky, Sergey; Piletska, Elena

    2008-01-01

    The combination of hydrophilic interaction liquid chromatography (HILIC) and liquid chromatography/mass spectrometry (LC/MS) for the determination of paralytic shellfish poisoning (PSP) toxins has been proposed for use in routine monitoring of shellfish. In this study, methods for the detection of multiple PSP toxins [saxitoxin (STX), neosaxitoxin (NEO), decarbamoyl saxitoxin (dcSTX), decarbamoyl neosaxitoxin (dcNEO), gonyautoxins 1-5 (GTX1, GTX2, GTX3, GTX4, GTX5), decarbamoyl gonyautoxins (dcGTX2 and dcGTX3), and the N-sulfocarbamoyl C toxins (C1 and C2)] were optimized using single (MS) and triple quadrupole (MS/MS) instruments. Chromatographic separation of the toxins was achieved by using a TSK-gel Amide-80 analytical column, although superior chromatography was observed through application of a ZIC-HILIC column. Preparative procedures used to clean up shellfish extracts and concentrate PSP toxins prior to analysis were investigated. The capacity of computationally designed polymeric (CDP) materials and HILIC solid-phase extraction (SPE) cartridges to retain highly polar PSP toxins was explored. Three CDP materials and 2 HILIC cartridges were assessed for the extraction of PSP toxins from aqueous solution. Screening of the CDPs showed that all tested polymers adsorbed PSP toxins. A variety of elution procedures were examined, with dilute 0.01% acetic acid providing optimum recovery from a CDP based on 2-(trifluoromethyl)acrylic acid as the monomer. ZIC-HILIC SPE cartridges were superior to the PolyLC equivalent, with recoveries ranging from 70 to 112% (ZIC-HILIC) and 0 to 90% (PolyLC) depending on the PSP toxin. It is proposed that optimized SPE and HILIC-MS methods can be applied for the quantitative determination of PSP toxins in shellfish.

  5. Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases.

    Science.gov (United States)

    Boyacı, Ezel; Rodríguez-Lafuente, Ángel; Gorynski, Krzysztof; Mirnaghi, Fatemeh; Souza-Silva, Érica A; Hein, Dietmar; Pawliszyn, Janusz

    2015-05-11

    In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid-liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation. In the last two decades, the introduction of solid phase microextraction (SPME) has brought significant progress in the sample preparation area by facilitating on-site and in vivo applications, time weighted average (TWA) and instantaneous concentration determinations. Recently introduced matrix compatible coatings for SPME facilitate direct extraction from complex matrices and fill the gap in direct sampling from challenging matrices. Following introduction of SPME, numerous other microextraction approaches evolved to address limitations of the above mentioned techniques. There is not a single method that can be considered as a universal solution for sample preparation. This review aims to show the main advantages and limitations of the above mentioned sample

  6. Principles and applications of colorimetric solid-phase extraction with negligible depletion

    International Nuclear Information System (INIS)

    Dias, Neil C.; Porter, Marc D.; Fritz, James S.

    2006-01-01

    Colorimetric solid-phase extraction (C-SPE) is an integrated technique in which an analyte is selectively concentrated onto a disk and then quantitated by diffuse reflectance spectroscopy. This paper describes the results of an investigation that applies the concept of negligible depletion (ND) to C-SPE, representing the first application of ND concepts to solid-phase extractions. The approach relies on passing the minimal volume of sample through the disk required to reach an equilibrium in which the concentration of analyte in the sample entering and exiting the disk are equal. At this point, the amount of analyte extracted by the disk is proportional to the sample concentration but is independent of the sample volume passed through the disk. With this new method, called C-SPE/ND, the precise measurement of sample volume is no longer necessary. The work herein details the general principles of this new methodology, and validates its basic tenets in an investigation of the extraction of the organic dye methyl violet. The analytical capabilities of C-SPE/ND are then demonstrated by its application to measurements of iodine. Iodine is a biocide increasingly used as a simple and effective disinfectant for water in locations where municipal water treatment systems are potentially compromised. Thus, the ability to operate C-SPE in an ND mode notably enhances the broad-based utility of this methodology as a reliable and an easy-to-use analysis tool for water quality assessments. Since iodine is also the biocide used on NASAs Space Shuttle, C-SPE/ND has the potential to overcome problems associated with the removal of air bubbles entrapped in a water sample in the microgravity environment encountered in space exploration. Extensions of C-SPE/ND to facile determinations of other water quality parameters with respect to both earth- and space-based needs are briefly discussed

  7. Solid phase extraction of Am (III) by resins impregnated with multiply diglycolamide-functionalized ligands

    International Nuclear Information System (INIS)

    Gujar, R.B.; Ansari, S.A.; Mohapatra, P.K.; Verboom, W.

    2016-01-01

    Solvent extraction studies with multiply diglycolamide-functionalized extractants such as tripodal diglycolamide (T-DGA) or diglycolamide-functionalized calix(4)arene (C4DGA) ligands have shown excellent results as compared to those of normal DGA ligands such as TODGA. A very high selectivity for Am(III) has been reported with these ligands with respect to U(VI) and Pu(IV). High selectivities and large extraction efficiencies of these ligands towards trivalent f elements were ascribed to a co-operative complexation mechanism. Furthermore, the extraction efficiency of these ligands increased several folds in ionic liquid medium as compared to paraffinic solvents. It was of interest, therefore, to prepare extraction chromatographic resins by impregnation of solvent systems containing these ligands in an ionic liquid. In the present work, solid phase extraction studies were carried out using these two multiply diglycolamide-functionalized extractants, viz. T-DGA (resin I) and C4DGA (resin-II) containing the ionic liquid C 4 mim. NTf 2 impregnated on Chromosorb-W

  8. Sensitive, automatic method for the determination of diazepam and its five metabolites in human oral fluid by online solid-phase extraction and liquid chromatography with tandem mass spectrometry

    DEFF Research Database (Denmark)

    Jiang, Fengli; Rao, Yulan; Wang, Rong

    2016-01-01

    A novel and simple online solid-phase extraction liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of diazepam and its five metabolites including nordazepam, oxazepam, temazepam, oxazepam glucuronide, and temazepam glucuronide...... in human oral fluid. Human oral fluid was obtained using the Salivette(®) collection device, and 100 μL of oral fluid samples were loaded onto HySphere Resin GP cartridge for extraction. Analytes were separated on a Waters Xterra C18 column and quantified by liquid chromatography with tandem mass...

  9. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)], E-mail: Ensafi@cc.iut.ac.ir; Ghaderi, Ali R. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO{sub 3} and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 {mu}g of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO{sub 3} solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL{sup -1} Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL{sup -1} Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  10. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Ghaderi, Ali R.

    2007-01-01

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO 3 and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 μg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO 3 solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL -1 Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL -1 Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments

  11. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue.

    Science.gov (United States)

    Ensafi, Ali A; Ghaderi, Ali R

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5M HNO(3) and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 microg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5M HNO(3) solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ngmL(-1) Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ngmL(-1) Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  12. Headspace Solid Phase Microextraction in Pesticide Residues Analysis:1. Optimisation of Extraction Conditions

    Directory of Open Access Journals (Sweden)

    Rada Đurović

    2007-01-01

    Full Text Available The method of headspace solid phase microextraction (HS/SPME was successfully used in a simultaneous multicomponent analysis of hexachlorobenzene (HCB, tefluthrin, heptachlor, aldrin, chlorpyrifos, fenthion and bifenthrin in aqueous medium. Measurementswere performed using a nonpolar polydimethyl siloxane (PDMS fiber. Detection and quantification were done by gas chromatography/mass spectrometry (GC/MS.Optimal conditions for HS/SPME were determined both by performing extraction at different temperatures and examining extraction time profiles at constant temperature. Optimal extraction temperature for each pesticide studied was determined as follows: 60°C for HCB and for heptachlor, 80°C for aldrin and for chlorpyrifos, fenthion and tefluthrin, and temperature exceeding 80°C for bifenthrin. For the pesticide mixture studied, 60°C was identified as the optimum extraction temperature.Based on the time profiles obtained, it was confirmed that satisfactory extraction sensitivity can be obtained even for extraction times shorter than the time required to reach a sorption equilibrium. This conclusion was confirmed by linear concentration profiles obtained for the following ranges: 0.05-10 ng/ml (HCB, 0.05-25 ng/ml (tefluthrin, 0.05-40 ng/ml (heptachlor, 0.05-40 ng/ml (aldrin, 0.05-25 ng/ml (chlorpyrifos, 0.05-25 ng/ml (fenthionand 0.05-25 ng/ml (bifenthrin.Relative standard deviation (RSD values for triplicate measurements did not exceed 15%.

  13. Improved resins and novel materials and methods for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Ronald [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Solid-phase extraction (SPE) has grown to be one of the most widely used methods for isolation and preconcentration of a vast range of compounds from aqueous solutions. By modifying polymeric SPE resins with chelating functional groups, the selective uptake of metals was accomplished. The resin, along with adsorbed metals, was vaporized in the ICP and detection of the metals was then possible using either mass or emission spectroscopy. Drug analyses in biological fluids have received heightened attention as drug testing is on the increase both in sports and in the work environment. By using a direct-injection technique, biological fluids can be injected directly into the liquid chromatographic system with no pretreatment. A new surfactant, a sulfonated form of Brij-30 (Brij-S) is shown to prevent the uptake of serum proteins on commercial HPLC columns by forming a thin coating on the silica C18 surface. Excellent separations of eight or more drugs with a wide range of retention times were obtained. The separations had sharper peaks and lower retention times than similar separations performed with the surfactant sodium dodecylsulfate (SDS). Quantitative recovery of a number of drugs with limits of detection near 1 ppm with a 5 μl injection volume were obtained. Finally, a method for solid-phase extraction in a syringe is introduced. The system greatly reduced the volume of solvent required to elute adsorbed analytes from the SPE bed while providing a semi-automated setup. SPE in a syringe consists of a very small bed of resin-loaded membrane packed into a GC or HPLC syringe. After extraction, elution was performed with just a few μl of solvent. This small elution volume allowed injection of the eluent directly from the syringe into the chromatographic system, eliminating the handling problems associated with such small volumes.

  14. Separation of lanthanum (3) and neodymium (3) by tributyl phosphate extraction in the presence of solid phase

    International Nuclear Information System (INIS)

    Korotkevich, I.B.; Kolesnikov, A.A.; Bomshtejn, V.E.; Shikhaleeva, N.N.

    1987-01-01

    Lanthanum (3) and neodymium (3) extraction from nitric acid solutions by tributyl phosphate in the presence of solid phase of the element nitrates is investigated. An increase in distribution of neodymium nitrate in the presence of solid phase with the decrease in its concentration in the initial solution and with the increase in lanthanum nitrate concentration is detected. The highest effect of extractive-crystallizational separation is observed in the range of neodymium nitrate microconcentrations. A method of neodymium quantitative extraction from lanthanum nitrate solutions with neodymium - lanthanum separation coefficient exceeding 25 is suggested

  15. [Corrected Title: Solid-Phase Extraction of Polar Compounds from Water] Automated Electrostatics Environmental Chamber

    Science.gov (United States)

    Sauer, Richard; Rutz, Jeffrey; Schultz, John

    2005-01-01

    A solid-phase extraction (SPE) process has been developed for removing alcohols, carboxylic acids, aldehydes, ketones, amines, and other polar organic compounds from water. This process can be either a subprocess of a water-reclamation process or a means of extracting organic compounds from water samples for gas-chromatographic analysis. This SPE process is an attractive alternative to an Environmental Protection Administration liquid-liquid extraction process that generates some pollution and does not work in a microgravitational environment. In this SPE process, one forces a water sample through a resin bed by use of positive pressure on the upstream side and/or suction on the downstream side, thereby causing organic compounds from the water to be adsorbed onto the resin. If gas-chromatographic analysis is to be done, the resin is dried by use of a suitable gas, then the adsorbed compounds are extracted from the resin by use of a solvent. Unlike the liquid-liquid process, the SPE process works in both microgravity and Earth gravity. In comparison with the liquid-liquid process, the SPE process is more efficient, extracts a wider range of organic compounds, generates less pollution, and costs less.

  16. Solid-Phase Extraction of Sulfur Mustard Metabolites Using an Activated Carbon Fiber Sorbent.

    Science.gov (United States)

    Lee, Jin Young; Lee, Yong Han

    2016-01-01

    A novel solid-phase extraction method using activated carbon fiber (ACF) was developed and validated. ACF has a vast network of pores of varying sizes and microporous structures that result in rapid adsorption and selective extraction of sulfur mustard metabolites according to the pH of eluting solvents. ACF could not only selectively extract thiodiglycol and 1-methylsulfinyl-2-[2-(methylthio)-ethylsulfonyl]ethane eluting a 9:1 ratio of dichloromethane to acetone, and 1,1'-sulfonylbis[2-(methylsulfinyl)ethane] and 1,1'-sulfonylbis- [2-S-(N-acetylcysteinyl)ethane] eluting 3% hydrogen chloride in methanol, but could also eliminate most interference without loss of analytes during the loading and washing steps. A sample preparation method has been optimized for the extraction of sulfur mustard metabolites from human urine using an ACF sorbent. The newly developed extraction method was applied to the trace analysis of metabolites of sulfur mustard in human urine matrices in a confidence-building exercise for the analysis of biomedical samples provided by the Organisation for the Prohibition of Chemical Weapons. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Recent Developments in Solid-Phase Extraction for Near and Attenuated Total Reflection Infrared Spectroscopic Analysis

    Directory of Open Access Journals (Sweden)

    Christian W. Huck

    2016-05-01

    Full Text Available A review with more than 100 references on the principles and recent developments in the solid-phase extraction (SPE prior and for in situ near and attenuated total reflection (ATR infrared spectroscopic analysis is presented. New materials, chromatographic modalities, experimental setups and configurations are described. Their advantages for fast sample preparation for distinct classes of compounds containing different functional groups in order to enhance selectivity and sensitivity are discussed and compared. This is the first review highlighting both the fundamentals of SPE, near and ATR spectroscopy with a view to real sample applicability and routine analysis. Most of real sample analyses examples are found in environmental research, followed by food- and bioanalysis. In this contribution a comprehensive overview of the most potent SPE-NIR and SPE-ATR approaches is summarized and provided.

  18. Ionic liquid-modified materials for solid-phase extraction and separation: a review.

    Science.gov (United States)

    Vidal, Lorena; Riekkola, Marja-Liisa; Canals, Antonio

    2012-02-17

    In recent years, materials science has propelled to the research forefront. Ionic liquids with unique and fascinating properties have also left their footprints to the developments of materials science during the last years. In this review we highlight some of their recent advances and provide an overview at the current status of ionic liquid-modified materials applied in solid-phase extraction, liquid and gas chromatography and capillary electrochromatography with reference to recent applications. In addition, the potential of ionic liquids in the modification of capillary inner wall in capillary electrophoresis is demonstrated. The main target material modified with ionic liquids is silica, but polymers and monoliths have recently joined the studies. Although imidazolium is still clearly the most commonly used ionic liquid for the covalently modification of materials, the exploitation of pyridinium and phosphonium will most probably increase in the future. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Headspace Solid Phase Micro Extraction Gas Chromatographic Determination of Fenthion in Human Serum

    Directory of Open Access Journals (Sweden)

    Kyriaki Machera

    2008-05-01

    Full Text Available A simple and effective analytical procedure was developed for the determination of fenthion residues in human serum samples. The sample treatment was performed using the headspace solid-phase micro extraction with polyacrylate fiber, which has the advantage to require low amount of serum (1 mL without tedious pre-treatment. The quantification of fenthion was carried out by gas chromatography-mass spectrometry and the recoveries ranged from 79 to 104% at two spiking levels for 6 replicates. Detection and quantification limits were calculated as 1.51 and 4.54 ng/mL of serum respectively. Two fenthion metabolites − fenoxon and fenthion–sulfoxide − were also identified.

  20. Solid-phase extraction and high-performance liquid chromatographic separation of pigments of red wines.

    Science.gov (United States)

    Csiktusnádi Kiss, G A; Forgács, E; Cserháti, T; Candeias, M; Vilas-Boas, L; Bronze, R; Spranger, I

    2000-08-11

    The adsorption and desorption capacities of 11 different solid-phase extraction sorbents were tested for the preconcenration of pigments of various Hungarian red wines. The concentrates were evaluated by multiwavelengh spectrophotometry combined with a spectral mapping technique (SPM) and by reversed-phase high-performance liquid chromatography. The highest (10-fold) concentration of pigments was achieved on octadecylsilica sorbent. It can be used five times without losing adsorption and desorption characteristics. SPM indicated that multiwavelength spectrophotometry can be employed for the differentiation of red wines. Comparison of the chromatograms of pigments with and without preconcentration showed that preconcentration makes possible the separation and detection of pigments present in low concentration in red wines.

  1. Preliminary evaluation of new polymer matrix for solid-phase extraction of nonylphenol from water samples.

    Science.gov (United States)

    Guerreiro, António; Soares, Ana; Piletska, Elena; Mattiasson, Bo; Piletsky, Sergey

    2008-03-31

    Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g(-1) for blank and 228 mg g(-1) for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.

  2. Solid phase extraction of copper(II) by fixed bed procedure on cation exchange complexing resins.

    Science.gov (United States)

    Pesavento, Maria; Sturini, Michela; D'Agostino, Girolamo; Biesuz, Raffaela

    2010-02-19

    The efficiency of the metal ion recovery by solid phase extraction (SPE) in complexing resins columns is predicted by a simple model based on two parameters reflecting the sorption equilibria and kinetics of the metal ion on the considered resin. The parameter related to the adsorption equilibria was evaluated by the Gibbs-Donnan model, and that related to the kinetics by assuming that the ion exchange is the adsorption rate determining step. The predicted parameters make it possible to evaluate the breakthrough volume of the considered metal ion, Cu(II), from different kinds of complexing resins, and at different conditions, such as acidity and ionic composition. Copyright 2009. Published by Elsevier B.V.

  3. DNA extraction on bio-chip: history and preeminence over conventional and solid-phase extraction methods.

    Science.gov (United States)

    Ayoib, Adilah; Hashim, Uda; Gopinath, Subash C B; Md Arshad, M K

    2017-11-01

    This review covers a developmental progression on early to modern taxonomy at cellular level following the advent of electron microscopy and the advancement in deoxyribonucleic acid (DNA) extraction for expatiation of biological classification at DNA level. Here, we discuss the fundamental values of conventional chemical methods of DNA extraction using liquid/liquid extraction (LLE) followed by development of solid-phase extraction (SPE) methods, as well as recent advances in microfluidics device-based system for DNA extraction on-chip. We also discuss the importance of DNA extraction as well as the advantages over conventional chemical methods, and how Lab-on-a-Chip (LOC) system plays a crucial role for the future achievements.

  4. Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

    Science.gov (United States)

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2004-01-23

    High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

  5. A rapid, solid phase extraction (SPE technique for the extraction and gas chromatographic determination lindane pesticide residue in tissue and milk

    Directory of Open Access Journals (Sweden)

    Yuningsih

    2006-03-01

    Full Text Available Organochlorine pesticide contamination in feed can cause residue in animal product (tissue and milk, so its become a problem in food safety. Solid phase extraction (SPE has been carried out for determination organochlorine pesticide residues in food animal production. The technique was rapid, not costly and produce limited amount of hazardous-waste. Samples were homogenized with acetonitrile trough cartridge C18, eluted in fluorocyl column with 2% ether-petroleum or acetonitrile fortissue and milk samples respectively. The recoveries of tissue sample by addition lindane standard solution: 0.50 and 1.00 μg are 85.10 and 103.10% respectively, while that of milk with the addition of 0.50, 1.00 and 1.50 μg are 83.80, 88.69 and 91.24% respectively. Three replicates were carried out for every sample. According of validation criteria of FAO/IAEA the recovery for analysis of pesticide residues was 70-110%. Therefore, the method is applicable.

  6. Experimental and computational studies on molecularly imprinted solid-phase extraction for gonyautoxins 2,3 from dinoflagellate Alexandrium minutum.

    Science.gov (United States)

    Lian, Ziru; Li, Hai-Bei; Wang, Jiangtao

    2016-08-01

    An innovative and effective extraction procedure based on molecularly imprinted solid-phase extraction (MISPE) was developed for the isolation of gonyautoxins 2,3 (GTX2,3) from Alexandrium minutum sample. Molecularly imprinted polymer microspheres were prepared by suspension polymerization and and were employed as sorbents for the solid-phase extraction of GTX2,3. An off-line MISPE protocol was optimized. Subsequently, the extract samples from A. minutum were analyzed. The results showed that the interference matrices in the extract were obviously cleaned up by MISPE procedures. This outcome enabled the direct extraction of GTX2,3 in A. minutum samples with extraction efficiency as high as 83 %, rather significantly, without any need for a cleanup step prior to the extraction. Furthermore, computational approach also provided direct evidences of the high selective isolation of GTX2,3 from the microalgal extracts.

  7. Fully automated synthesis of ¹¹C-acetate as tumor PET tracer by simple modified solid-phase extraction purification.

    Science.gov (United States)

    Tang, Xiaolan; Tang, Ganghua; Nie, Dahong

    2013-12-01

    Automated synthesis of (11)C-acetate ((11)C-AC) as the most commonly used radioactive fatty acid tracer is performed by a simple, rapid, and modified solid-phase extraction (SPE) purification. Automated synthesis of (11)C-AC was implemented by carboxylation reaction of MeMgBr on a polyethylene Teflon loop ring with (11)C-CO2, followed by acidic hydrolysis with acid and SCX cartridge, and purification on SCX, AG11A8 and C18 SPE cartridges using a commercially available (11)C-tracer synthesizer. Quality control test and animals positron emission tomography (PET) imaging were also carried out. A high and reproducible decay-uncorrected radiochemical yield of (41.0 ± 4.6)% (n=10) was obtained from (11)C-CO2 within the whole synthesis time about 8 min. The radiochemical purity of (11)C-AC was over 95% by high-performance liquid chromatography (HPLC) analysis. Quality control test and PET imaging showed that (11)C-AC injection produced by the simple SPE procedure was safe and efficient, and was in agreement with the current Chinese radiopharmaceutical quality control guidelines. The novel, simple, and rapid method is readily adapted to the fully automated synthesis of (11)C-AC on several existing commercial synthesis module. The method can be used routinely to produce (11)C-AC for preclinical and clinical studies with PET imaging. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Optimization of Solid Phase Micro-Extraction (SPME for Monitoring Occupational Exposure to Ethyl Benzene

    Directory of Open Access Journals (Sweden)

    H Heidari

    2012-05-01

    Full Text Available

    Background and Objectives: Analytical methods for volatile organic compounds (VOCs in different samples need extraction of compounds, by applying hazardous solvents. Solid phase micro-extraction (SPME is a solvent-free equilibrium extraction method, in which proper calibration can allow quantitative determinations of VOCs at a very good sensitivity without the use of any organic solvent. VOCs are generally present in urine only at trace levels, therefore, a sensitive procedure is needed for their trace determinations. Throughout this study, headspace solid phase micro-extraction (HS-SPME was followed by GC-FID for ethyl benzene in spiked urine was optimized.

    Methods: In this study, the parameters influencing SPME and gas chromatography of ethyl benzene, including extraction time, temperature, desorption temperature, desorption time, salt addition, sample pH, sample volume and sample agitation were investigated.

    Results: Extraction procedure was performed at 30°C for 6 min, using 0.2 gml-1 of NaCl in the sample solution. The sample volume and sample pH were optimized at 5 ml and 7 (neutral pH, respectively. Desorption of the ethyl benzene was carried out for 60 sec. at 250°C. The method was also validated with three different spiked urine samples and illustrated an appropriate reproducibility over six consecutive days as well as six within-day experiments. During this investigation, parameters of accuracy, linearity, and detection limits of the procedure were also evaluated.

    Conclusion: The developed method of HS- SPME-GC-FID proved to be a simple, convenient, and practical procedure, and was successfully used for measuring of ethyl benzene in spiked urine.

  9. A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters by use of solid-phase extraction, and its applications to brackish lake waters.

    Science.gov (United States)

    Okumura, M; Tong, L; Fujinaga, K; Seike, Y

    2001-05-01

    A simple and rapid in situ preconcentration method for the determination of phosphate in environmental waters has been developed for field analysis. This method is based on solid-phase extraction on a zirconium-loaded Sep-Pack Accell CM cartridge (Zr-SP) and is applicable to studies in which sampling is performed by use of a graduated syringe to prevent contamination and to ensure easy operation at sampling sites. The Zr-SP cartridge was prepared by passing 0.1 mol L(-1) zirconium solution through a Sep-Pak Accell CM cartridge, packed with cation exchange sorbent based on a silica matrix. The adsorption of phosphate and its desorption depend only on the pH of the solution. A water sample containing phosphate was adjusted to pH 2 and passed through the Zr-SP cartridge to collect it. The retained phosphate was quantitatively eluted with 0.5 mol L(-1) sodium hydroxide solution. The phosphate retained in the Zr-SP cartridge was stable for at least one month. The established preconcentration method was successfully applied to brackish lake waters to investigate seasonal changes in the distribution and behavior of phosphate in a brackish lake.

  10. Solid phase microextraction and stir bar sorptive extraction for organotin compounds - a comparison (P9)

    International Nuclear Information System (INIS)

    Mothes, S.; Wennrich, R.

    2002-01-01

    Full text: Organotin compounds have been largely used in agricultural and industrial applications. Hyphenated techniques were developed for the sensitive and selective determination of such species. For this task GC has been coupled with atomic emission detection. Derivatization to transform the Sn-compounds into sufficiently volatile compounds was necessary and carried out using sodium tetrapropylborate. For sample preparation the application of solid phase microextraction (SPME) give recent advances in comparison to classical liquid-liquid extraction (LEE). A problem in the usage of SPME exists however in the small volume of the PDMS coating for enrichment the analytes. For improvement of both sample enrichment and extraction of the organotin compounds stir bar sorptive extraction (SBSE) was applied. It base on the application of stir bars coated with PDMS. Here the extraction yield is substantially higher. Aim of this study was to compare the capabilities of GC-AED in combination with SPME and SBSE. After optimization of the experimental parameters it was possible to reach detection limits in the pg / 1 - level. A comparison of both methods shows the expected results. By application of SBSE it was possible to increase the detection limits one order of magnitude. With SPME the reproducibility of the analytical results (in the 1 ng / 1 concentration range) was found to be between 10 and 15 %, it could be enhanced to 5-8 % by application of SBSE. These low limits of detection and the good reproducibility allowed the determination of organotin compounds according required regulations. Ref. 1 (author)

  11. A rapid solid-phase extraction fluorometric method for thiamine and riboflavin in salmonid eggs

    Science.gov (United States)

    Zajicek, James L.; Tillitt, Donald E.; Brown, Scott B.; Brown, Lisa R.; Honeyfield, Dale C.; Fitzsimons, John D.

    2005-01-01

    A new method has been developed and successfully applied to the selective measurement of thiamine (nonphosphorylated), total thiamine (sum of thiamine, thiamine monophosphate [TMP], thiamine diphosphate [TDP], and thiamine triphosphate [TTP]), and potentially interfering riboflavin in acidic (2% trichloroacetic acid) extracts of selected salmonid and walleye egg samples. Acidic extracts of eggs were applied directly to end-capped C18, reversed-phase solid-phase extraction (SPE) columns and separated into three fractions by elution with mixtures of PO4 buffer (pH 2), methanol (10%), and acetonitrile (20%). All thiamine compounds recovered in the first two fractions were oxidized to their corresponding thiochromes with alkaline potassium hexacyanoferrate, and we measured the thiochrome fluorescence (excitation at 360 nm, emission at 460 nm) in a 96-well microplate reader. Riboflavin, recovered in third fraction (eluted with pH 2, 20% acetonitrile), was analyzed directly by measuring the fluorescence of this fraction (excitation at 450 nm, emission at 530 nm). Significant portions of the phosphate esters of thiamine (TMP, TDP, and presumably TTP), when present at low concentrations (extract thiamine compounds into 2% trichlororacetic acid solution; an inexpensive, commercially available SPE column; small amounts of sample (0.5-1 g); microliter volumes of solvents per sample; a traditional, relatively nonhazardous, oxidation of thiamine compounds to fluorescent thiochromes; and an ultraviolet-visible-wavelength-filter fluorometer for the measurements. ?? Copyright by the American Fisheries Society 2005.

  12. Volatile composition of peppermint (Mentha piperita L.) commercial teas through solid phase extraction.

    Science.gov (United States)

    Riachi, L G; Abi-Zaid, I E; Moreira, R F A; De Maria, C A B

    2012-12-01

    Volatiles from aqueous extract of peppermint commercial sachets were investigated through gas chromatography/flame ionization detection (GC/FID) and GC/mass spectrometry (MS). Samples were prepared under similar conditions as in homemade tea. Volatiles were isolated using solid phase extraction method (SPE) with Porapak Q trap followed by desorption with acetone. Estimated mean values for short and medium chain carboxylic acids (C2-C12) and ketones lay in the range of 50-64 microg kg(-1) whilst aliphatic alcohols and acyclic hydrocarbons had values lower than 6 microg kg(-1). The major volatiles were terpenes (275-382 microg kg(-1)) that reached 89 % of the total composition. A total of 16 compounds, among them dodecane, acetoin, acetol, citral, geraniol and octanoic acid have been described by the first time in peppermint tea. These findings could be attributed to the different analytical approach employed, mainly to the use of different extraction/pre-concentration techniques. Given the apparently lower proportion of terpenes in the aqueous extract it may be that the chemical properties of the peppermint essential oil are not entirely reproduced with homemade tea.

  13. Magnetic solid-phase extraction of protein with deep eutectic solvent immobilized magnetic graphene oxide nanoparticles.

    Science.gov (United States)

    Xu, Kaijia; Wang, Yuzhi; Ding, Xueqin; Huang, Yanhua; Li, Na; Wen, Qian

    2016-01-01

    As a new type of green solvent, four kinds of choline chloride (ChCl)-based deep eutectic solvents (DESs) have been synthesized, and then a core-shell structure magnetic graphene oxide (Fe3O4-NH2@GO) nanoparticles have been prepared and coated with the ChCl-based DESs. Magnetic solid-phase extraction (MSPE) based Fe3O4-NH2@GO@DES was studied for the first time for the extraction of proteins. The characteristic results of vibrating sample magnetometer (VSM), X-ray diffraction (XRD), Fourier transform infrared spectrometry (FT-IR), thermal gravimetric analysis (TGA) and field emission scanning electron microscopy (FESEM) indicated the successful preparation of Fe3O4-NH2@GO@DES. The concentrations of proteins in studies were determined by a UV-vis spectrophotometer. The advantages of Fe3O4-NH2@GO@DES in protein extraction were compared with Fe3O4-NH2@GO and Fe3O4-NH2, and Fe3O4-NH2@GO@ChCl-glycerol was selected as the suitable extraction solvent. The influence factors of the extraction process such as the pH value, the temperature, the extraction time, the concentration of protein and the amount of Fe3O4-NH2@GO@ChCl-glycerol were evaluated. Desorption experimental result showed 98.73% of BSA could be eluted from the solid extractant with 0.1 mol/L Na2HPO4 solution contained 1 mol/L NaCl. Besides, the conformation of BSA was not changed during the elution by the investigation of circular dichromism (CD) spectra. Furthermore, the analysis of real sample demonstrated that the prepared magnetic nanoparticles did have extraction ability on proteins in bovine whole blood. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction.

    Science.gov (United States)

    Jochmann, Maik A; Yuan, Xue; Schmidt, Torsten C

    2007-03-01

    In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-microm film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons.

  15. Determination of volatile organic hydrocarbons in water samples by solid-phase dynamic extraction

    Energy Technology Data Exchange (ETDEWEB)

    Jochmann, Maik A.; Schmidt, Torsten C. [Eberhard-Karls-Universitaet Tuebingen, Center for Applied Geoscience (ZAG), Tuebingen (Germany); Chair of Instrumental Analysis, University Duisburg-Essen, Duisburg (Germany); Yuan, Xue [Eberhard-Karls-Universitaet Tuebingen, Center for Applied Geoscience (ZAG), Tuebingen (Germany)

    2007-03-15

    In the present study a headspace solid-phase dynamic extraction method coupled to gas chromatography-mass spectrometry (HS-SPDE-GC/MS) for the trace determination of volatile halogenated hydrocarbons and benzene from groundwater samples was developed and evaluated. As target compounds, benzene as well as 11 chlorinated and brominated hydrocarbons (vinyl chloride, dichloromethane, cis-1,2-dichloroethylene, trans-1,2-dichloroethylene, carbon tetrachloride, chloroform, trichloroethylene, tetrachloroethylene, bromoform) of environmental and toxicological concern were included in this study. The analytes were extracted using a SPDE needle device, coated with a poly(dimethylsiloxane) with 10% embedded activated carbon phase (50-{mu}m film thickness and 56-mm film length) and were analyzed by GC/MS in full-scan mode. Parameters that affect the extraction yield such as extraction and desorption temperature, salting-out, extraction and desorption flow rate, extraction volume and desorption volume, the number of extraction cycles, and the pre-desorption time have been evaluated and optimized. The linearity of the HS-SPDE-GC/MS method was established over several orders of magnitude. Method detection limits (MDLs) for the compounds investigated ranged between 12 ng/L for cis-dichloroethylene and trans-dichloroethylene and 870 ng/L for vinyl chloride. The method was thoroughly validated, and the precision at two concentration levels (0.1 mg/L and a concentration 5 times above the MDL) was between 3.1 and 16% for the analytes investigated. SPDE provides high sensitivity, short sample preparation and extraction times and a high sample throughput because of full automation. Finally, the applicability to real environmental samples is shown exemplarily for various groundwater samples from a former waste-oil recycling facility. Groundwater from the site showed a complex contamination with chlorinated volatile organic compounds and aromatic hydrocarbons. (orig.)

  16. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    Energy Technology Data Exchange (ETDEWEB)

    Herrero Latorre, C., E-mail: carlos.herrero@usc.es [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain); Alvarez Mendez, J.; Barciela Garcia, J.; Garcia Martin, S.; Pena Crecente, R.M. [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain)

    2012-10-24

    Highlights: Black-Right-Pointing-Pointer The use of CNTs as sorbent for metal species in solid phase extraction has been described. Black-Right-Pointing-Pointer Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. Black-Right-Pointing-Pointer Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes - due to their high adsorption and desorption capacities - have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  17. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    International Nuclear Information System (INIS)

    Herrero Latorre, C.; Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R.M.

    2012-01-01

    Highlights: ► The use of CNTs as sorbent for metal species in solid phase extraction has been described. ► Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. ► Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  18. Surfactant-enhanced spectrofluorimetric determination of total aflatoxins from wheat samples after magnetic solid-phase extraction using modified Fe3O4 nanoparticles

    Science.gov (United States)

    Manafi, Mohammad Hanif; Allahyari, Mehdi; Pourghazi, Kamyar; Amoli-Diva, Mitra; Taherimaslak, Zohreh

    2015-07-01

    The extraction and preconcentration of total aflatoxins (including aflatoxin B1, B2, G1, and G2) using magnetic nanoparticles based solid phase extraction (MSPE) followed by surfactant-enhanced spectrofluorimetric detection was proposed. Ethylene glycol bis-mercaptoacetate modified silica coated Fe3O4 nanoparticles as an efficient antibody-free adsorbent was successfully applied to extract aflatoxins from wheat samples. High surface area and strong magnetization properties of magnetic nanoparticles were utilized to achieve high enrichment factor (97), and satisfactory recoveries (92-105%) using only 100 mg of the adsorbent. Furthermore, the fast separation time (less than 10 min) avoids many time-consuming cartridge loading or column-passing procedures accompany with the conventional SPE. In determination step, signal enhancement was performed by formation of Triton X-100 micelles around the analytes in 15% (v/v) acetonitrile-water which dramatically increase the sensitivity of the method. Main factors affecting the extraction efficiency and signal enhancement of the analytes including pH of sample solution, desorption conditions, extraction time, sample volume, adsorbent amount, surfactant concentration and volume and time of micelle formation were evaluated and optimized. Under the optimum conditions, wide linear range of 0.1-50 ng mL-1 with low detection limit of 0.03 ng mL-1 were obtained. The developed method was successfully applied to the extraction and preconcentration of aflatoxins in three commercially available wheat samples and the results were compared with the official AOAC method.

  19. Separation of lanthanum (3) and samarium (3) extraction with tributylphosphate in the solvent presence of solid phase

    International Nuclear Information System (INIS)

    Korotkevich, I.B.; Kolesnikov, A.A.; Bomshtejn, V.E.

    1990-01-01

    Lanthanum (3) and samarium (3) extraction from nitric acid solutions by tributylphosphate in the presence of solid phase has been investigated. An increase in samarium α-nitrate distribution factor in the presence of solid phase with a decrease in its concentration in the initial solution and with lanthanum nitrate concentration increase is detected. The greatest effect of separation is observed in samarium nitrate microregion. The method of quantitative extraction of samarium from lanthanum nitrate solutions with samarium-lanthanum separation factor exceeding 50 has been suggested

  20. Speciation analysis of mercury by dispersive solid-phase extraction coupled with capillary electrophoresis.

    Science.gov (United States)

    Li, Jinhua; Liu, Junying; Lu, Wenhui; Gao, Fangfang; Wang, Liyan; Ma, Jiping; Liu, Huitao; Liao, Chunyang; Chen, Lingxin

    2018-04-23

    A pretreatment method of dispersive solid-phase extraction (DSPE) along with back-extraction followed by CE-UV detector was developed for the determination of mercury species in water samples. Sulfhydryl-functionalized SiO 2 microspheres (SiO 2 -SH) were synthesized and used as DSPE adsorbents for selective extraction and enrichment of three organic mercury species namely ethylmercury (EtHg), methylmercury (MeHg), and phenylmercury (PhHg), along with L-cysteine (L-cys) containing hydrochloric acid as back-extraction solvent. Several main extraction parameters were systematically investigated including sample pH, amount of adsorbent, extraction and back-extraction time, volume of eluent, and concentration of hydrochloric acid. Under optimal conditions, good linearity was achieved with correlation coefficients over 0.9990, in the range of 4-200 μg/L for EtHg, and 2-200 μg/L for MeHg and PhHg. The LODs were obtained of 1.07, 0.34, and 0.24 μg/L for EtHg, MeHg, and PhHg, respectively, as well as the LOQs were 3.57, 1.13, and 0.79 μg/L, respectively, with enrichment factors ranging from 109 to 184. Recoveries were attained with tap and lake water samples in a range of 62.3-107.2%, with relative standard deviations of 3.5-10.1%. The results proved that the method of SiO 2 -SH based DSPE coupled with CE-UV was a simple, rapid, cost-effective, and eco-friendly alternative for the determination of mercury species in water samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Optimization of cloud point extraction and solid phase extraction methods for speciation of arsenic in natural water using multivariate technique.

    Science.gov (United States)

    Baig, Jameel A; Kazi, Tasneem G; Shah, Abdul Q; Arain, Mohammad B; Afridi, Hassan I; Kandhro, Ghulam A; Khan, Sumaira

    2009-09-28

    The simple and rapid pre-concentration techniques viz. cloud point extraction (CPE) and solid phase extraction (SPE) were applied for the determination of As(3+) and total inorganic arsenic (iAs) in surface and ground water samples. The As(3+) was formed complex with ammonium pyrrolidinedithiocarbamate (APDC) and extracted by surfactant-rich phases in the non-ionic surfactant Triton X-114, after centrifugation the surfactant-rich phase was diluted with 0.1 mol L(-1) HNO(3) in methanol. While total iAs in water samples was adsorbed on titanium dioxide (TiO(2)); after centrifugation, the solid phase was prepared to be slurry for determination. The extracted As species were determined by electrothermal atomic absorption spectrometry. The multivariate strategy was applied to estimate the optimum values of experimental factors for the recovery of As(3+) and total iAs by CPE and SPE. The standard addition method was used to validate the optimized methods. The obtained result showed sufficient recoveries for As(3+) and iAs (>98.0%). The concentration factor in both cases was found to be 40.

  2. Microporous Carbon Spheres Solid Phase Membrane Tip Extraction for the Analysis of Nitrosamines in Water Samples

    International Nuclear Information System (INIS)

    Mohammed Salisu Musa; Wan Aini Wan Ibrahim

    2015-01-01

    A simple solid phase membrane tip extraction (SPMTE) utilizing microporous carbon spheres (MCS) was developed for the analysis of nitrosamines in aqueous samples. The method termed MCS-SPMTE was optimized for various important extraction parameters namely conditioning organic solvent, extraction time, effects of salt addition and pH change, desorption time, desorption solvent and sample volume. Under the optimized conditions, the method indicated good linearity in the range of 10-100 μg/ L with coefficients of determination, r 2 ≥0.9984. The method also demonstrated good reproducibility with % RSDs values ranging from 2.2 - 8.9 (n = 3). Limit of detection (LOD) and limit of quantification (LOQ) for the method ranged from 3.2 - 4.8 μg/ L and 10.9 - 15.9 μg/L respectively. Recoveries for both tap-water and lake water samples spiked at 10 μg/L were in the range of 83.2 - 107.5 %. (author)

  3. Application of solid phase micro extraction (SPME) in profiling hydrocarbons in oil spill cases

    International Nuclear Information System (INIS)

    Zuraidah Abdullah Munir; Norashikin Saim; Nurul Huda Mamat Ghani

    2008-01-01

    In environmental forensic, it is extremely important to have a fast and reliable method in identifying sources of spilled oil and petroleum products. In this study, solid phase micro extraction (SPME) method coupled to gas chromatography-mass spectrometry was developed for the analysis of hydrocarbons in diesel and petroleum contaminated soil samples. Optimization of SPME parameters such as extraction time, extraction temperature and desorption time, was performed using 100-μm poly dimethylsiloxane (PDMS) fiber. These parameters were studied at three levels by means of a central composite experimental design and the optimum experimental conditions were determined using response surface method. The developed SPME method was applied to determine the profiles of hydrocarbons in several oil contaminated soil sample. The SPME method was also used to study the effects of weathering on the profiles of hydrocarbons in unleaded gasoline, diesel and kerosene contaminated soil samples. After several days, significant losses of the lighter hydrocarbons were observed compared to the heavier ones. From these data, SPME method can be used to differentiate possible candidate sources in oil spill cases. (author)

  4. [Optimization of solid-phase extraction for enrichment of toxic organic compounds in water samples].

    Science.gov (United States)

    Zhang, Ming-quan; Li, Feng-min; Wu, Qian-yuan; Hu, Hong-ying

    2013-05-01

    A concentration method for enrichment of toxic organic compounds in water samples has been developed based on combined solid-phase extraction (SPE) to reduce impurities and improve recoveries of target compounds. This SPE method was evaluated in every stage to identify the source of impurities. Based on the analysis of Waters Oasis HLB without water samples, the eluent of SPE sorbent after dichloromethane and acetone contributed 85% of impurities during SPE process. In order to reduce the impurities from SPE sorbent, soxhlet extraction of dichloromethane followed by acetone and lastly methanol was applied to the sorbents for 24 hours and the results had proven that impurities were reduced significantly. In addition to soxhlet extraction, six types of prevalent SPE sorbents were used to absorb 40 target compounds, the lgK(ow) values of which were within the range of 1.46 and 8.1, and recovery rates were compared. It was noticed and confirmed that Waters Oasis HLB had shown the best recovery results for most of the common testing samples among all three styrenedivinylbenzene (SDB) polymer sorbents, which were 77% on average. Furthermore, Waters SepPak AC-2 provided good recovery results for pesticides among three types of activated carbon sorbents and the average recovery rates reached 74%. Therefore, Waters Oasis HLB and Waters SepPak AC-2 were combined to obtain a better recovery and the average recovery rate for the tested 40 compounds of this new SPE method was 87%.

  5. Solid phase extraction of magnetic carbon doped Fe3O4 nanoparticles.

    Science.gov (United States)

    Yang, Jing; Li, Jia-yuan; Qiao, Jun-qin; Lian, Hong-zhen; Chen, Hong-yuan

    2014-01-17

    Carbon decorated Fe3O4 nanoparticles (Fe3O4/C) are promising magnetic solid-phase extraction (MSPE) sorbents in environmental and biological analysis. Fe3O4/C based MSPE method shows advantages of easy operation, rapidness, high sensitivity, and environmental friendliness. In this paper, the MSPE mechanism of Fe3O4/C nanoparticles has been comprehensively investigated, for the first time, through the following three efforts: (1) the comparison of extraction efficiency for polycyclic aromatic hydrocarbons (PAHs) between the Fe3O4/C sorbents and activated carbon; (2) the chromatographic retention behaviors of hydrophobic and hydrophilic compounds on Fe3O4/C nanoparticles as stationary phase; (3) related MSPE experiments for several typical compounds such as pyrene, naphthalene, benzene, phenol, resorcinol, anisole and thioanisole. It can be concluded that there are hybrid hydrophobic interaction and hydrogen bonding interaction or dipole-dipole attraction between Fe3O4/C sorbents and analytes. It is the existence of carbon and oxygen-containing functional groups coated on the surface of Fe3O4/C nanoparticles that is responsible for the effective extraction process. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Determination of Iron Species by Combination of Solvent Assisted-Dispersive Solid Phase Extraction and Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Zahra Dehghani

    2015-06-01

    Full Text Available A simple, rapid and sensitive solvent assisted-dispersive solid phase extraction method was developed for the extraction of iron(II prior to its spectrophotometric determination. The Fe(II reacted with 2,4,6-tris(2-pyridyl-1,3,5-triazine, neutralized with sodium dodecyl sulfate and extracted onto the fine particles of benzophenone which were formed upon rapid injection of a mixture of benzophenone as the sorbent and ethanol as the disperser solvent into the aqueous solution. After phase separation, the sedimented phase containing the complex was dissolved in ethanol and the analyte concentration was determined by measuring its absorption at 594 nm. Total iron was determined after the reduction of Fe(III to Fe(II with hydroxylamine hydrochloride. Under the optimized conditions, an enhancement factor of 32, the detection limit of 0.16 µg l-1, and the relative standard deviation of 1.9% (n = 6 at 20 µg l-1 concentration level of Fe(II were achieved. The method was successfully applied to the determination of iron species in water samples and total iron in infant dry formula milk, apple, rice, spinach and parsley samples.

  7. Improved solid-phase extraction method for systematic toxicological analysis in biological fluids.

    Science.gov (United States)

    Soriano, T; Jurado, C; Menéndez, M; Repetto, M

    2001-03-01

    A method for the simultaneous qualitative and quantitative determination of drugs of abuse (opiates, cocaine, or amphetamines) and prescribed drugs (tricyclic antidepressants, phenotiazines, benzodiazepines, etc.) in biological fluids--blood, urine, bile, and gastric contents--was developed. This procedure involves solid-phase extraction with Bond-Elut Certify columns followed by analysis by gas chromatography-nitrogen-phosphorus detection (GC-NPD) and confirmation by gas chromatography-mass spectrometry (GC-MS), after derivatization, when necessary. Pretreatment was performed on all samples: sonication for 15 min plus enzymatic hydrolysis with beta-glucuronidase in urine. With respect to the internal standards, nalorphine and trihexylamine were used for basic substances, allobarbital for acidic drugs, and prazepam for benzodiazepines. Acidic and basic compounds were extracted from different aliquots of samples at different pH levels: 6-6.5 for the acidic and neutral and 8-8.5 for the basic and the benzodiazepines. Several areas of experimental design were considered in the process of method optimization. These included internal standards, pH, sonication, flow rate and washing solvents. It was found that systematic analysis could be reliably performed using optimized extraction conditions. The recovery rates for the compounds tested were always higher than 61.02%.

  8. [Determination of Arsenic in Food Package Aluminum by Ultrasound Assisted Solid Phase Extraction/ICP-AES].

    Science.gov (United States)

    Qin, Wen-xia; Gong, Qi; Li, Min; Deng, Li-xin; Mo, Li-shu; Li, Yan-lin

    2015-04-01

    Determination of arsenic in pure aluminum by inductively coupled plasma atomic emission spectrometry was interfered by aluminum matrix. The experiment showed that when the mass concentration of Al was greater than or equal to 5 000 times the As in the test solution, the measurement error was greater than 5%. In order to eliminate the interference, strong acid cation exchange fiber (SACEF) was used as solid phase extraction agent to adsorb Al(3+). The extraction conditions included amount of SACEF, extraction time, temperature and pH were investigated. The optimal extraction conditions were that 0.9000 g SACEF was used to extract the aluminum from the sample solution of pH 2.0 at 55 °C for 5 min with the ultrasonic assist, and in this case, the arsenic in the form of arsenic acid was not extracted and left in the solution for the determination. The results showed that after treating 10. 00 mL test solution containing 1.00 µg arsenic and 20.0 mg aluminum, arsenic did not lose. The mass concentration of residual aluminum in the raffinate was about 2,000 times the As, which had not interfered the determination of arsenic. The detection limit (3 s) was 0.027 µg · mL(-1) and quantification limit (10 s) was 0.0091 µg · mL(-1). The proposed method was successfully applied to the separation and determination of arsenic in the synthetic samples, the aluminum cans and the barbecue aluminum foil. Recovery was in the range of 98.3%-105% and RSD (n = 3) was in the range of 0.1%-4.3%. The results showed that the content of arsenic in the aluminum cans and the aluminum barbecue foil was below the limited value of national standard (GB/T 3190-2008).

  9. Graphene oxide for solid-phase extraction of bioactive phenolic acids.

    Science.gov (United States)

    Hou, Xiudan; Wang, Xusheng; Sun, Yingxin; Wang, Licheng; Guo, Yong

    2017-05-01

    A solid-phase extraction (SPE) method for the efficient analysis of trace phenolic acids (PAs, caffeic acid, ferulic acid, protocatechuic acid, cinnamic acid) in urine was established. In this work, a graphene oxide (GO) coating was grafted onto pure silica to be investigated as SPE material. The prepared GO surface had a layered and wrinkled structure that was rough and well organized, which could provide more open adsorption sites. Owing to its hydrophilicity and polarity, GO showed higher extraction efficiency toward PAs than reduced GO did, in agreement with the theoretical calculation results performed by Gaussian 09 software. The adsorption mechanism of PAs on GO@Sil was also investigated through static state and kinetic state adsorption experiments, which showed a monolayer surface adsorption. Extraction capacity of the as-prepared material was optimized using the response surface methodology. Under the optimized conditions, the as-established method provided wide linearity range (2-50 μg L -1 for protocatechuic acid and 1-50 μg L -1 for caffeic acid, ferulic acid, and cinnamic acid) and low limits of detection (0.25-1 μg L -1 ). Finally, the established method was applied for the analysis of urine from two healthy volunteers. The results indicate that the prepared material is a practical, cost-effective medium for the extraction and determination of phenolic acids in complex matrices. Graphical Abstract A graphene oxide coating was grafted onto pure silica as the SPE material for the extraction of phenolic acids in urines and the extraction mechanism was also mainly investigated.

  10. A simple solid-phase extraction method for the analysis of red cell phospholipids by liquid chromatography- tandem mass spectrometry.

    Science.gov (United States)

    Nguyen, Van Long

    2018-02-25

    There has been increasing interest in the analysis of phospholipids in red blood cells as potential long-term biomarkers of different disease states. Here, we describe a simple method for the analysis of two phospholipids: 1-Palmitoyl-2-oleoyl-sn-glycero-3-phosphoethanol (PE 16:0/18:1) and 1-Palmitoyl-2-linoleoyl-sn-glycero-3-phosphoethanol (PE 16:/0/18:2) in erythrocytes by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Whole blood samples were removed free of plasma and washed in isotonic saline. Red cells were lysed with ultrapure water. Lysate samples were processed using a hybrid solid-phase extraction (SPE) phospholipid cartridge (1 mL, 30 mg). Both PE 16:0/18:1 and PE 16:0/18:2 and their deuterated internal standards were separated on an ACE C4 (150 mm × 2.1 mm, 2.7 μm particle size) by gradient elution at a flow rate of 0.5 mL per minute using mobile phases consisting of 0.01 mol/L ammonium acetate in: water (A), methanol (B), and isopropanol (C). The phospholipid species were quantified by the following transitions: PE 16:0/18:1: 701.5→281.3 and PE 16:0/18:2: 699.5→279.3. Both PE species displayed linearity ranging from 10 to 500 μg/L. The coefficient of variation (CV%) of PE 16:0/18:1 concerning intraday and interday precision was between 1.9%-2.6% and 3.0%-4.3%, respectively. For PE 16:0/18:2, this was between 1.8%-3.4% and 3.7%-4.1%, respectively. Both phospholipid species had accuracy (PE 16:0/18:1: 91%-98% and PE 16:0/18:2: 94%-103%) and extraction recovery (PE 16:0/18:1: 95%-106% and PE 16:0/18:2: 92%-102%) exceeding 90% over the analytical range. The limit of detection was 5 μg/L. Here we propose a simple SPE LC-MS/MS method for analyzing phospholipids in erythrocytes, which can be easily adopted. © 2018 Wiley Periodicals, Inc.

  11. ZnO nanorod array polydimethylsiloxane composite solid phase micro-extraction fiber coating: fabrication and extraction capability.

    Science.gov (United States)

    Wang, Dan; Wang, Qingtang; Zhang, Zhuomin; Chen, Guonan

    2012-01-21

    ZnO nanorod array coating is a novel kind of solid-phase microextraction (SPME) fiber coating which shows good extraction capability due to the nanostructure. To prepare the composite coating is a good way to improve the extraction capability. In this paper, the ZnO nanorod array polydimethylsiloxane (PDMS) composite SPME fiber coating has been prepared and its extraction capability for volatile organic compounds (VOCs) has been studied by headspace sampling the typical volatile mixed standard solution of benzene, toluene, ethylbenzene and xylene (BTEX). Improved detection limit and good linear ranges have been achieved for this composite SPME fiber coating. Also, it is found that the composite SPME fiber coating shows good extraction selectivity to the VOCs with alkane radicals.

  12. Magnetic solid phase extraction and gas chromatography-mass spectrometrical analysis of sixteen polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Cai, Ying; Yan, Zhihong; NguyenVan, Manh; Wang, Lijia; Cai, Qingyun

    2015-08-07

    Fluorenyl functionalized superparamagnetic core/shell magnetic nanoparticles (MNPs, Fe3O4@SiO2@Flu) were prepared and characterized by transmission electron microscope, X-ray diffraction and infrared spectroscopy. The MNPs having an average diameter of 200nm were then used as solid-phase extraction sorbent for the determination of 16 priority pollutants polycyclic aromatic hydrocarbons (PAHs) in water samples designated by United States Environmental Protection Agency (U.S. EPA). The main influencing parameters, including sorbent amount, desorption solvent, sample volume and extraction time were optimized. Analyses were performed on gas chromatography-mass spectrometry (GC-MS) using selected ion monitoring (SIM) mode. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels. Limit of detection ranging from 0.5 to 4.0ng/L were obtained. The repeatability was investigated by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) lower than 13.1%. Finally, the proposed method was successfully applied for the determination of PAHs in water samples with the recoveries in the range of 96.0-106.7%. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Fabricating and Characterizing the Microfluidic Solid Phase Extraction Module Coupling with Integrated ESI Emitters

    Directory of Open Access Journals (Sweden)

    Hangbin Tang

    2018-05-01

    Full Text Available Microfluidic chips coupling with mass spectrometry (MS will be of great significance to the development of relevant instruments involving chemical and bio-chemical analysis, drug detection, food and environmental applications and so on. In our previous works, we proposed two types of microfluidic electrospray ionization (ESI chip coupling with MS: the two-phase flow focusing (FF ESI microfluidic chip and the corner-integrated ESI emitter, respectively. However the pretreatment module integrated with these ESI emitters is still a challenging problem. In this paper, we concentrated on integrating the solid phase micro-extraction (SPME module with our previous proposed on-chip ESI emitters; the fabrication processes of such SPME module are fully compatible with our previous proposed ESI emitters based on the multi-layer soft lithography. We optimized the structure of the integrated chip and characterized its performance using standard samples. Furthermore, we verified its abilities of salt removal, extraction of multiple analytes and separation through on-chip elution using mimic biological urine spiked with different drugs. The results indicated that our proposed integrated module with ESI emitters is practical and effective for real biological sample pretreatment and MS detection.

  14. Solid phase extraction of uranium(VI) onto benzoylthiourea-anchored activated carbon

    International Nuclear Information System (INIS)

    Zhao Yongsheng; Liu Chunxia; Feng Miao; Chen Zhen; Li Shuqiong; Tian Gan; Wang Li; Huang Jingbo; Li Shoujian

    2010-01-01

    A new solid phase extractant selective for uranium(VI) based on benzoylthiourea anchored to activated carbon was developed via hydroxylation, amidation and reaction with benzoyl isothiocyanate in sequence. Fourier transform infrared spectroscopy and total element analysis proved that benzoylthiourea had been successfully grafted to the surface of the activated carbon, with a loading capacity of 1.2 mmol benzoylthiourea per gram of activated carbon. The parameters that affect the uranium(VI) sorption, such as contact time, solution pH, initial uranium(VI) concentration, adsorbent dose and temperature, have been investigated. Results have been analyzed by Langmuir and Freundlich isotherm; the former was more suitable to describe the sorption process. The maximum sorption capacity (82 mg/g) for uranium(VI) was obtained at experimental conditions. The rate constant for the uranium sorption by the as-synthesized extractant was 0.441 min -1 from the first order rate equation. Thermodynamic parameters (ΔH 0 = -46.2 kJ/mol; ΔS 0 = -98.0 J/mol K; ΔG 0 = -17.5 kJ/mol) showed the adsorption of an exothermic process and spontaneous nature, respectively. Additional studies indicated that the benzoylthiourea-anchored activated carbon (BT-AC) selectively sorbed uranyl ions in the presence of competing ions, Na + , Co 2+ , Sr 2+ , Cs + and La 3+ .

  15. Solid phase extraction of uranium(VI) onto benzoylthiourea-anchored activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Yongsheng; Liu Chunxia; Feng Miao; Chen Zhen; Li Shuqiong; Tian Gan; Wang Li; Huang Jingbo [College of Chemistry, Sichuan University, 29 Wangjiang Lu, Chengdu, 610064, Sichuan (China); Li Shoujian, E-mail: sjli000616@scu.edu.cn [College of Chemistry, Sichuan University, 29 Wangjiang Lu, Chengdu, 610064, Sichuan (China)

    2010-04-15

    A new solid phase extractant selective for uranium(VI) based on benzoylthiourea anchored to activated carbon was developed via hydroxylation, amidation and reaction with benzoyl isothiocyanate in sequence. Fourier transform infrared spectroscopy and total element analysis proved that benzoylthiourea had been successfully grafted to the surface of the activated carbon, with a loading capacity of 1.2 mmol benzoylthiourea per gram of activated carbon. The parameters that affect the uranium(VI) sorption, such as contact time, solution pH, initial uranium(VI) concentration, adsorbent dose and temperature, have been investigated. Results have been analyzed by Langmuir and Freundlich isotherm; the former was more suitable to describe the sorption process. The maximum sorption capacity (82 mg/g) for uranium(VI) was obtained at experimental conditions. The rate constant for the uranium sorption by the as-synthesized extractant was 0.441 min{sup -1} from the first order rate equation. Thermodynamic parameters ({Delta}H{sup 0} = -46.2 kJ/mol; {Delta}S{sup 0} = -98.0 J/mol K; {Delta}G{sup 0} = -17.5 kJ/mol) showed the adsorption of an exothermic process and spontaneous nature, respectively. Additional studies indicated that the benzoylthiourea-anchored activated carbon (BT-AC) selectively sorbed uranyl ions in the presence of competing ions, Na{sup +}, Co{sup 2+}, Sr{sup 2+}, Cs{sup +} and La{sup 3+}.

  16. Highly selective solid-phase extraction of trace Pd(II) by murexide functionalized halloysite nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Li Ruijun; He Qun; Hu Zheng; Zhang Shengrui [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, Lanzhou 730000 (China); Zhang Lijun [Faculty of Science and Engineer, Curtin University, Perth, WA 6845 (Australia); Chang Xijun, E-mail: lirj2010@lzu.edu.cn [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Key Laboratory of Nonferrous Metal Chemistry and Resources Utilization of Gansu Province, Lanzhou 730000 (China)

    2012-02-03

    Graphical abstract: Murexide functionalized halloysite nanotubes have been developed to separate and concentrate trace Pd(II) from aqueous samples. Parameters that affected the sorption and elution efficiency were studied in column mode, and the new adsorbent presented high selectivity and adsorption capacity for the solid phase extraction of trace Pd(II). Highlights: Black-Right-Pointing-Pointer Murexide modified halloysite nanotubes as adsorbent has been reported originally. Black-Right-Pointing-Pointer This adsorbent has a unique selectivity for Pd(II) at pH 1.0. Black-Right-Pointing-Pointer This adsorbent had high adsorption capacity for Pd(II). Black-Right-Pointing-Pointer The precision and accuracy of the method are satisfactory. - Abstract: The originality on the high efficiency of murexide modified halloysite nanotubes as a new adsorbent of solid phase extraction has been reported to preconcentrate and separate Pd(II) in solution samples. The new adsorbent was confirmed by Fourier transformed infrared spectra, X-ray diffraction, scanning electron microscope, transmission electron microscope and N{sub 2} adsorption-desorption isotherms. Effective preconcentration conditions of analyte were examined using column procedures prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of pH, the amount of adsorbent, the sample flow rate and volume, the elution condition and the interfering ions were optimized in detail. Under the optimized conditions, Pd(II) could be retained on the column at pH 1.0 and quantitatively eluted by 2.5 mL of 0.01 mol L{sup -1} HCl-3% thiourea solution at a flow rate of 2.0 mL min{sup -1}. The analysis time was 5 min. An enrichment factor of 120 was accomplished. Common interfering ions did not interfere in both separation and determination. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 42.86 mg g{sup -1} for Pd(II). The detection limit (3{sigma}) of

  17. Highly selective solid-phase extraction of trace Pd(II) by murexide functionalized halloysite nanotubes

    International Nuclear Information System (INIS)

    Li Ruijun; He Qun; Hu Zheng; Zhang Shengrui; Zhang Lijun; Chang Xijun

    2012-01-01

    Graphical abstract: Murexide functionalized halloysite nanotubes have been developed to separate and concentrate trace Pd(II) from aqueous samples. Parameters that affected the sorption and elution efficiency were studied in column mode, and the new adsorbent presented high selectivity and adsorption capacity for the solid phase extraction of trace Pd(II). Highlights: ► Murexide modified halloysite nanotubes as adsorbent has been reported originally. ► This adsorbent has a unique selectivity for Pd(II) at pH 1.0. ► This adsorbent had high adsorption capacity for Pd(II). ► The precision and accuracy of the method are satisfactory. - Abstract: The originality on the high efficiency of murexide modified halloysite nanotubes as a new adsorbent of solid phase extraction has been reported to preconcentrate and separate Pd(II) in solution samples. The new adsorbent was confirmed by Fourier transformed infrared spectra, X-ray diffraction, scanning electron microscope, transmission electron microscope and N 2 adsorption–desorption isotherms. Effective preconcentration conditions of analyte were examined using column procedures prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of pH, the amount of adsorbent, the sample flow rate and volume, the elution condition and the interfering ions were optimized in detail. Under the optimized conditions, Pd(II) could be retained on the column at pH 1.0 and quantitatively eluted by 2.5 mL of 0.01 mol L −1 HCl–3% thiourea solution at a flow rate of 2.0 mL min −1 . The analysis time was 5 min. An enrichment factor of 120 was accomplished. Common interfering ions did not interfere in both separation and determination. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 42.86 mg g −1 for Pd(II). The detection limit (3σ) of the method was 0.29 ng mL −1 , and the relative standard deviation (RSD) was 3.1% (n = 11). The method was

  18. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, M.; Mulder, P.P.J.; Bire, R.; Hess, P.; Boer, de J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC¿MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  19. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, A. M.; Mulder, P.P.J.; Bire, L.; Hess, P.; de Boer, J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  20. The use of solid phase extraction method for analysis of residues of pesticides used in banana production in Costa Rica

    International Nuclear Information System (INIS)

    Castillo, L.E.; Ruepert, C.; Alfaro, A.R.; Solis, E.

    1999-01-01

    Different solid phase extraction devices were tested for the analysis of residues of eleven pesticides used in banana production in Costa Rica. The analysis was performed by using gas chromatograph equipped with NPD and ECD detectors. In general low recoveries and high variation coefficients were found for chlorothalonil, imazalil, terbufos and thiabendazole. For the other pesticides recoveries ranged between 60 and over 100%. (author)

  1. Sorption behavior of charged and neutral polar organic compounds on solid phase extraction materials: which functional group governs sorption?

    NARCIS (Netherlands)

    Bäuerlein, P.S.; Mansell, J.E.; ter Laak, T.L.; de Voogt, P.

    2012-01-01

    Numerous polar anthropogenic organic chemicals have been found in the aqueous environment. Solid phase extraction (SPE) has been applied for the isolation of these from aqueous matrices, employing various materials. Nevertheless, little is known about the influence of functional groups on the

  2. Serum protein profiling by miniaturized solid-phase extraction and matrix-assisted laser desorption/ionization mass spectrometry

    DEFF Research Database (Denmark)

    Callesen, Anne K; Mohammed, Shabaz; Bunkenborg, Jakob

    2005-01-01

    for translation of MALDI-MS based diagnostic methods to clinical applications. We have investigated a number of MALDI matrices and several miniaturized solid-phase extraction (SPE) methods for serum protein concentration and desalting with the aim of generating reproducible, high-quality protein profiles by MALDI...

  3. Mycoestrogen determination in cow milk: Magnetic solid-phase extraction followed by liquid chromatography and tandem mass spectrometry analysis.

    Science.gov (United States)

    Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; La Barbera, Giorgia; Samperi, Roberto; Ventura, Salvatore; Laganà, Aldo

    2016-12-01

    Recently, magnetic solid-phase extraction has gained interest because it presents various operational advantages over classical solid-phase extraction. Furthermore, magnetic nanoparticles are easy to prepare, and various materials can be used in their synthesis. In the literature, there are only few studies on the determination of mycoestrogens in milk, although their carryover in milk has occurred. In this work, we wanted to develop the first (to the best of our knowledge) magnetic solid-phase extraction protocol for six mycoestrogens from milk, followed by liquid chromatography and tandem mass spectrometry analysis. Magnetic graphitized carbon black was chosen as the adsorbent, as this carbonaceous material, which is very different from the most diffuse graphene and carbon nanotubes, had already shown selectivity towards estrogenic compounds in milk. The graphitized carbon black was decorated with Fe 3 O 4 , which was confirmed by the characterization analyses. A milk deproteinization step was avoided, using only a suitable dilution in phosphate buffer as sample pretreatment. The overall process efficiency ranged between 52 and 102%, whereas the matrix effect considered as signal suppression was below 33% for all the analytes even at the lowest spiking level. The obtained method limits of quantification were below those of other published methods that employ classical solid-phase extraction protocols. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Determination of phenprocoumon in plasma and urine using at-line solid-phase extraction-capillary electrophoresis.

    NARCIS (Netherlands)

    Veraart, J.R.; Gooijer, C.; Lingeman, H.; Velthorst, N.H.; Brinkman, U.A.T.

    1998-01-01

    The use of capillary electrophoresis (CE) for the analysis of biological samples is rather problematic because of the large number of interferences present in the matrix. One of the possibilities to solve such problems is to couple solid-phase extraction (SPE) at-line with CE, a technique developed

  5. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids

    NARCIS (Netherlands)

    Schellen, A.; Ooms, B.; Lagemaat, D. van de; Vreeken, R.; Dongen, W.D. van

    2003-01-01

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS

  6. Rapid determination of six carcinogenic primary aromatic amines in mainstream cigarette smoke by two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Bie, Zhenying; Lu, Wei; Zhu, You; Chen, Yusong; Ren, Hubo; Ji, Lishun

    2017-01-27

    A fully automated, rapid, and reliable method for simultaneous determination of six carcinogenic primary aromatic amines (AAs), including o-toluidine (o-TOL), 2, 6-dimethylaniline (2, 6-DMA), o-anisidine (o-ASD), 1-naphthylamine (1-ANP), 2-naphthylamine (2-ANP), and 4-aminobiphenyl (4-ABP), in mainstream cigarette smoke was established. The proposed method was based on two-dimensional online solid phase extraction combined with liquid chromatography tandem mass spectrometry (SPE/LC-MS/MS). The particulate phase of the mainstream cigarette smoke was collected on a Cambridge filter pad and pretreated via ultrasonic extraction with 2% formic acid (FA), while the gas phase was trapped by 2% FA without pretreatment for determination. The two-dimensional online SPE comprised of two cartridges with different absorption characteristics was applied for sample pretreatment. Analysis was performed by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) under multiple reaction monitoring mode. Each sample required about 0.5h for solid phase extraction and analysis. The limit of detections (LODs) for six AAs ranged from 0.04 to 0.58ng/cig and recoveries were within 84.5%-122.9%. The relative standard deviations of intra- and inter-day tests for 3R4F reference cigarette were less than 6% and 7%, respectively, while no more than 7% and 8% separately for a type of Virginia cigarette. The proposed method enabled minimum sample pretreatment, full automation, and high throughput with high selectivity, sensitivity, and accuracy. As a part of the validation procedure, fifteen brands of cigarettes were tested by the designed method. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of bismuth and cadmium after solid-phase extraction with chromosorb-107 in a syringe

    International Nuclear Information System (INIS)

    Tokman, Nilgun; Akman, Suleyman

    2004-01-01

    The determination of bismuth and cadmium by graphite furnace atomic absorption spectrometry (GFAAS) after solid-phase extraction (SPE) on Chromosorb-107 filled in a syringe was described. To retain the analytes, the sample solution treated with and without ammonium pyrolidine dithiocarbamate (APDC) was drawn into the syringe filled with Chromosorb-107 and discharged back manually. Bismuth and cadmium were quantitatively sorbed at pH ≥ 6 irrespective of whether the analyte was complexed with APDC prior to passing through the Chromosorb-107. Analyte elements sorbed on the resin were quantitatively eluted with 3.0 M of HNO 3 again drawing and discharging the eluent into the syringe and ejected it back. Optimum flow rates of sample or eluent for sorption and elution processes were 20 ml min -1 for drawing and 20 ml min -1 for discharging in all cases. Bismuth and cadmium were analyzed by graphite furnace atomic absorption spectrometry. The elements could be concentrated by drawing and discharging several portions of sample successively but eluting only one time. The validity of the proposed method was checked with standard reference materials (NIST SRM 1515 Apple-Leaves, CWW-TM-E Waste Water and CRM-SW Sea Water). The analyte elements were quantitatively (>95%) recovered from different matrices irrespective of treated samples with APDC. Detection limits (δ) were 0.8 and 1.2 μg l -1 for Bi and Cd, respectively. The method can be characterized with fastness, simplicity, quantitative recovery and high reproducibility

  8. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division; China Univ. of Geosciences, Wuhan (China). School of Environmental Studies; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Section, Emergencies, Operational Analytical Laboratories and Research Support Division

    2009-07-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  9. Identification and fingerprinting of biodiesel blends by solid phase extraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Yang, Z.; China Univ. of Geosciences, Wuhan; Hollebone, B.; Wang, Z.; Yang, C.; Landriault, M.

    2009-01-01

    Interest in biodiesel as a replacement for petroleum diesel fuel is growing. In North America, biodiesels are produced by the methyl esterification of plant and animal triglycerides, resulting in complex mixtures composed of fatty acid methyl esters (FAMEs). It is important for both environmental forensic and remediation purposes to determine diesel and biodiesel origins, and the biodiesel content when it is blended with conventional petroleum diesel. This paper reported on a study that combined 2 methods to determine biodiesel levels in blended fuels. Micro-column fractionation of FAMEs involving solid phase extraction (SPE) was combined with gas chromatography-mass spectrometry (GC/MS) to achieve detailed chemical fingerprinting of blends, including the identification and quantification of individual aliphatic hydrocarbons, aromatic hydrocarbons, fatty acid alkyl esters, and free sterols. Fractionation of the fuel samples was optimized for separation of fatty acid esters, free sterols from petroleum hydrocarbons into 4 fractions, notably aliphatic, aromatic, fatty-acid ester and polar components. A sum of the FAME components was used to determine an unknown blend level in freshly-prepared samples. This study showed that this method has great potential for identifying biodiesel in diesel fuel blends and could form the basis of a method for biodiesel-contaminated environmental samples. 28 refs., 5 tabs., 4 figs.

  10. Three modified activated carbons by different ligands for the solid phase extraction of copper and lead

    International Nuclear Information System (INIS)

    Ghaedi, M.; Ahmadi, F.; Tavakoli, Z.; Montazerozohori, M.; Khanmohammadi, A.; Soylak, M.

    2008-01-01

    In the presented work, 5,5-diphenylimidazolidine-2,4-dione (phenytoin) (DFTD), 5,5-diphenylimidazolidine-2-thione-,4-one (thiophenytoin) (DFID) and 2-(4'-methoxy-benzylidenimine) thiophenole (MBIP) modified activated carbons have been used for the solid phase extraction of copper and lead ions prior to their flame atomic absorption spectrometric determinations. The influences of the various analytical parameters including pH, amounts of reagent, sample volume and eluent type, etc. on the recovery efficiencies of copper and lead ions were investigated. The influences of alkaline, earth alkaline and some transition metals on the adsorption of the analytes were also examined. The detection limits by three sigma for analyte ions were 0.65 and 0.42 μg L -1 using activated carbon modified with DFID; 0.52 and 0.37 μg L -1 using activated carbon modified with DFTD and 0.46 and 0.31 μg L -1 using activated carbon modified with MBIP for Pb(II) and Cu(II), respectively. The procedure was applied to the determination of analytes in natural waters, soil, and blood samples with satisfactory results (recoveries greater than 95%, R.S.D.'s lower than 4%)

  11. Three modified activated carbons by different ligands for the solid phase extraction of copper and lead

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, M. [Chemistry Department, University of Yasouj, Yasouj 75914-353 (Iran, Islamic Republic of)], E-mail: m_ghaedi@mail.yu.ac.ir; Ahmadi, F.; Tavakoli, Z. [Gachsaran Azad University, Gachsaran (Iran, Islamic Republic of); Montazerozohori, M. [Chemistry Department, University of Yasouj, Yasouj 75914-353 (Iran, Islamic Republic of); Khanmohammadi, A. [Young Researchers Club, Gachsaran Azad University, Gachsaran (Iran, Islamic Republic of); Soylak, M. [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2008-04-15

    In the presented work, 5,5-diphenylimidazolidine-2,4-dione (phenytoin) (DFTD), 5,5-diphenylimidazolidine-2-thione-,4-one (thiophenytoin) (DFID) and 2-(4'-methoxy-benzylidenimine) thiophenole (MBIP) modified activated carbons have been used for the solid phase extraction of copper and lead ions prior to their flame atomic absorption spectrometric determinations. The influences of the various analytical parameters including pH, amounts of reagent, sample volume and eluent type, etc. on the recovery efficiencies of copper and lead ions were investigated. The influences of alkaline, earth alkaline and some transition metals on the adsorption of the analytes were also examined. The detection limits by three sigma for analyte ions were 0.65 and 0.42 {mu}g L{sup -1} using activated carbon modified with DFID; 0.52 and 0.37 {mu}g L{sup -1} using activated carbon modified with DFTD and 0.46 and 0.31 {mu}g L{sup -1} using activated carbon modified with MBIP for Pb(II) and Cu(II), respectively. The procedure was applied to the determination of analytes in natural waters, soil, and blood samples with satisfactory results (recoveries greater than 95%, R.S.D.'s lower than 4%)

  12. Developments in coupled solid-phase extraction-capillary electrophoresis 2013-2015.

    Science.gov (United States)

    Ramautar, Rawi; Somsen, Govert W; de Jong, Gerhardus J

    2016-01-01

    An overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems reported in the literature between July 2013 and June 2015 is provided in this paper. The present article is a continuation of our previous review papers on this topic which covered the time period 2000-2013 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54; Electrophoresis 2012, 33, 243-250; Electrophoresis 2014, 35, 128-137). The use of in-line and on-line SPE-CE approaches is treated and outlined in this review. Recent advancements, such as, for example, the use of aptamers as affinity material for in-line SPE-CE, the use of a bead string design for in-line fritless SPE-CE, and new interfacing techniques for the on-line coupling of SPE to CE, are outlined. Selected examples demonstrate the applicability of the coupled SPE-CE systems for biomedical, pharmaceutical, environmental, and food studies. A complete overview of the recent SPE-CE studies is given in table format, providing information on sample type, SPE sorbent, coupling mode, detection mode, and LOD. Finally, some general conclusions and perspectives are provided. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Determination of Inorganic Arsenic in Natural Water by Solid Phase Extraction

    International Nuclear Information System (INIS)

    Nazaratul Ashifa Abdullah Salim; Amares Chatt, A.

    2011-01-01

    Arsenic (As) is generally known for its toxicity. The toxicity and mobility of As in the environment are dependent on the chemical forms or species in which it exists. Arsenic (III) and (V) are the most often determined species in environmental water, soil and sediment, while organic As species are common constituents of biological tissue and fluids. It is well known that inorganic As, such as arsenite (As(III)) and arsenate (As(V)) are more toxic than their organic counterparts. This study is conducted to investigate the separation of each As inorganic species using solid phase extraction (SPE) technique. The technique utilizes SPE column for selective retention of As species, followed by elution and measurement of eluted fractions by inductively coupled plasma mass spectrometry (ICP-MS) for total As. Several type of SPE columns namely strongly anion exchange (SAX), strongly cation exchange (SCX), weakly anion exchange (WAX) and weakly cation exchange (WCX) were tested using three different types of media including deionized water, succinic acid and acetic acid containing inorganic As species. The SPE technique is suitable for on-site separation and preservation of As species from water. (author)

  14. Solid phase extraction for sample preparation in trace analysis of ionogenic compounds by capillary isotachophoresis

    International Nuclear Information System (INIS)

    Hutta, M.; Kaniansky, D.; Simunicova, E.; Zelenska, V.; Madajova, V.; Siskova, A.

    1992-01-01

    Various sorbents recommended for solid phase extraction (SPE) in sample preparation procedures were studied for use in combination with capillary isotachophoresis (ITP). They were very efficient in achieving trace concentration levels (low ppb, i.e., low parts per 10 9 ) for different types of ITP analytes present in environmental and biological matrices. A macroporous carbon sorbent was convenient for sample preparation in ITP analysis of short chain fatty acids (C 4 -C 9 ) in drinking water. Chelating sorbents based on hydroxyalkyl methacrylate matrix with salicylate, thioglycolate and 8-hydroxyquinolinate functionalities were found to be very suitable for preconcentration of heavy metals with an inherent sample clean-up. An octadecyl-bonded silica sorbent enabled in ITP a photometric detection of γ-aminobutyrate (labeled with a 2,4,6-trinitrophenyl group) at concentrations considerably lower than required for the determination of this amino acid in cerebrospinal fluid (∼5*10 -8 mol/l). (author) 34 refs.; 3 figs.; 1 tab

  15. Application of solid-phase extraction coupled with freezing-lipid filtration clean-up for the determination of endocrine-disrupting phenols in fish

    International Nuclear Information System (INIS)

    Ahn, Yun Gyong; Shin, Jeoung Hwa; Kim, Hye-Young; Khim, Jeehyeong; Lee, Mi-Kyoung; Hong, Jongki

    2007-01-01

    An analytical method has been developed for the determination of endocrine-disrupting phenols (eight alkylphenols and bisphenol A) in fish samples. The extraction of nine phenols from fish samples was carried out by ultrasonification. After the extraction, high levels of lipids were removed by freezing-lipid filtration instead of the traditional methods of column chromatography or saponification. During freezing-lipid filtration, about 90% of the lipids were eliminated without any significant loss of phenolic compounds. For further purification, hydrophilic-lipophilic balanced copolymer (HLB) sorbent with a poly(divinylbenzene-co-N-vinylpyrrolidone) phase and Florisil-solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. Silyl-derivatization, with N,N'-methyl-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA), was applied to enhance the sensitivity of detection of phenolic compounds. Quantification was performed by gas chromatography/mass spectrometry (GC/MS)-selected ion monitoring (SIM) mode, using deuterium-labeled internal standards. Spiking experiments were carried out to determine the recovery, precision and detection limit of the method. The overall recoveries ranged between 70 and 120%, with relative standard deviations of 3-17% for the entire procedure. The detection limits of the method for the nine phenols ranged from 0.02 to 0.41 ng g -1 . The method provided simultaneous screening and accurate confirmation of each phenol when applied to biological samples

  16. Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction.

    Science.gov (United States)

    Deng, Fenfang; Yu, Hong; Pan, Xinhong; Hu, Guoyuan; Wang, Qiqin; Peng, Rongfei; Tan, Lei; Yang, Zhicong

    2018-02-23

    This paper demonstrated the development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of five glycopeptide antibiotics in food and biological samples. The target glycopeptide antibiotics were isolated from the samples by solvent extraction, and the extracts were cleaned with a tandem solid-phase extraction step using mixed strong cation exchange and hydrophilic/lipophilic balance cartridges. Subsequently, the analytes were eluted with different solvents, and then quantified by UHPLC-MS/MS in the positive ionization mode with multiple reaction monitoring. Under optimal conditions, good linear correlations were obtained for the five glycopeptide antibiotics in the concentration range of 1.0 μg/L to 20.0 μg/L, and with linear correlation coefficients >0.998. Employing this method, the target glycopeptide antibiotics in food and biological samples were identified with a recovery of 83.0-102%, and a low quantitation limit of 1.0 μg/kg in food and 2.0 μg/L in biological samples with low matrix effects. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Application of solid-phase extraction coupled with freezing-lipid filtration clean-up for the determination of endocrine-disrupting phenols in fish

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yun Gyong [Hazardous Substance Research Team, Korea Basic Science Institute, Seoul 136-701 (Korea, Republic of); Department of Civil Environment Engineering, Korea University, Seoul 136-701 (Korea, Republic of); Shin, Jeoung Hwa; Kim, Hye-Young [Hazardous Substance Research Team, Korea Basic Science Institute, Seoul 136-701 (Korea, Republic of); Khim, Jeehyeong [Department of Civil Environment Engineering, Korea University, Seoul 136-701 (Korea, Republic of); Lee, Mi-Kyoung [College of Pharmacy, Kyung Hee University, Seoul 130-701 (Korea, Republic of); Hong, Jongki [College of Pharmacy, Kyung Hee University, Seoul 130-701 (Korea, Republic of)], E-mail: jhong@khu.ac.kr

    2007-11-05

    An analytical method has been developed for the determination of endocrine-disrupting phenols (eight alkylphenols and bisphenol A) in fish samples. The extraction of nine phenols from fish samples was carried out by ultrasonification. After the extraction, high levels of lipids were removed by freezing-lipid filtration instead of the traditional methods of column chromatography or saponification. During freezing-lipid filtration, about 90% of the lipids were eliminated without any significant loss of phenolic compounds. For further purification, hydrophilic-lipophilic balanced copolymer (HLB) sorbent with a poly(divinylbenzene-co-N-vinylpyrrolidone) phase and Florisil-solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. Silyl-derivatization, with N,N'-methyl-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA), was applied to enhance the sensitivity of detection of phenolic compounds. Quantification was performed by gas chromatography/mass spectrometry (GC/MS)-selected ion monitoring (SIM) mode, using deuterium-labeled internal standards. Spiking experiments were carried out to determine the recovery, precision and detection limit of the method. The overall recoveries ranged between 70 and 120%, with relative standard deviations of 3-17% for the entire procedure. The detection limits of the method for the nine phenols ranged from 0.02 to 0.41 ng g{sup -1}. The method provided simultaneous screening and accurate confirmation of each phenol when applied to biological samples.

  18. Membrane solid-phase extraction: Field application for isolation of polycyclic aromatic hydrocarbons from water samples

    International Nuclear Information System (INIS)

    Furlong, E.T.; Koleis, J.C.; Gates, P.M.

    1995-01-01

    Solid-phase extraction (SPE) membranes (M-SPE) were used to isolate microgram-per-liter to nanogram-per-liter quantities of polycyclic aromatic hydrocarbons (PAH) in 4- to 8-liter ground-water samples from a crude-oil-contaminated ground-water site near Bemidji, Minnesota. The M-SPE method was evaluated (1) under laboratory conditions using reagent water fortified with individual PAH at 1.23 micrograms per liter, and (2) at the Bemidji site. At the site, ground-water samples were processed and PAH isolated using a M-SPE system connected directly to the well pump. Following sample isolation, all M-SPE samples were extracted using dichloromethane and analyzed by gas chromatography-mass spectrometry with selected-ion monitoring. Operationally, the M-SPE method provided a simple means to isolate PAH on site at the wellhead, particularly for anoxic water samples. Acceptable recoveries, ranging from 56 to over 100 percent, were observed for lower molecular weight PAH (naphthalene to pyrene) using the M-SPE method. Recoveries using M-SPE were somewhat lower, but reproducible, for higher molecular weight PAH (chrysene to benzo[ghi]perylene), ranging from 18 to 56 percent. M-SPE provides the capability to collect and field isolate PAH from a sufficiently large number of samples to identify environmental chemical processes occurring at individual compound concentrations of 50 to 1,200 nanograms per liter. Using M-SPE, the potential for facilitated transport of PAH by in situ-derived dissolved organic carbon (DOC) was evaluated at the site. Plots comparing DOC and PAH concentrations indicate that PAH concentrations increase exponentially with linear increases in DOC concentrations

  19. Forensic analysis of high explosives residues in post-blast water samples employing solid phase extraction for analyte pro-concentration

    International Nuclear Information System (INIS)

    Umi Kalsom Ahmad; Rajendran, Sumathy; Ling, Lee Woan

    2008-01-01

    Nitro aromatic, nitramine and nitrate ester compounds are a major group of high order explosive or better known as military explosives. Octahydro-1,3,5,7-tetrazocine (HMX), 1,3,5-hexahydro-1,3,5-trinitro triazine (RDX), 2,4,6-trinitro-toluene (TNT), pentaerythritol tetranitrate (PETN) and 2,4-dinitrotoluene (2,4-DNT) are secondary high explosives classified as most commonly used explosives components. There is an increasing demand for pre-concentration of these compounds in water samples as the sensitivity achieved by instrumental analytical methods for these high explosives residues are the main drawback in the application at trace levels for forensic analysis. Hence, a simple cartridge solid phase extraction (SPE) procedure was optimized as the off-line extraction and pre-concentration method to enhance the detection limit of high explosive residues using micellar electrokinetic chromatography (MEKC) and gas chromatography with electron-capture detection (GC-ECD) methods. The SPE cartridges utilized LiChrolut EN as the SPE adsorbent. By emplying pre-concentration using SPE, the detection limits of the target analytes in water sample were lowered by more than 1000 times with good percentage recovery (>87%) for MEKC method and lowered by 120 times with more than 2 % percentage recovery for GC-ECD methods. In order to test the feasibility of the developed method to real cases, post-blast water samples were analyzed. The post-blast water samples which were collected from Baling Bom training range, Ulu Kinta, Perak contained RDX and PETN in the range of 0.05 - 0.17 ppm and 0.0124 - 0.0390 ppm respectively. (author)

  20. Magnetic micro-solid-phase-extraction of polycyclic aromatic hydrocarbons in water.

    Science.gov (United States)

    Naing, Nyi Nyi; Yau Li, Sam Fong; Lee, Hian Kee

    2016-04-01

    A novel sorbent, magnetic chitosan functionalized graphene oxide (MCFG) was synthesized and used in the micro-solid-phase-extraction (μ-SPE) and gas chromatography-mass spectrometric (GC-MS) analysis of polycyclic aromatic hydrocarbons (PAHs) from water. Through the use of the magnetic sorbent, the μ-SPE device also functioned as a stir bar during extraction. Three types of MCFG were prepared using glutaraldehyde cross-linked chitosan and graphene oxide with different amounts of magnetic nanoparticles (Fe3O4) (0.05g, 0.07g and 0.1g). The material was characterized using Fourier transform infrared spectroscopy and field emission scanning electron microscopy. Parameters affecting the extraction such as the type of sorbent, extraction and desorption times, volume of sample solution and type of desorption solvent were optimized. Under the most favourable conditions, the highest extraction was obtained by using the composite prepared with 0.1g of Fe3O4. For the latter material as sorbent, the linearity of the analytes was in the range of 0.01 and 100μgL(-1) for naphthalene, fluoranthene and pyrene while acenaphthylene and phenanthrene exhibited linearity in the range of 0.05 and 100μgL(-1). For fluorene and anthracene, the linearity range was from 0.01 to 50μgL(-1). The coefficients of determination (r(2)) associated with the above linear ranges were higher than 0.987. The limits of detection from GC-MS analysis of the seven PAHs were in the range 0.2-1.8ngL(-1); limits of quantification were between 0.8 and 5.9ngL(-1) while the relative standard deviations (RSDs) varied from 2.1 to 8.2%. The recoveries of the method for the compounds at spiking levels of 1 and 5μgL(-1) were in the range 67.5-106.9% with RSDs below 15%. The enrichment factors were found to be in between 67 and 302. The developed method afforded an interesting and innovative approach using MCFG as an efficient and promising sorbent. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Colorimetric Solid Phase Extraction (CSPE): Using Color to Monitor Spacecraft Water Quality

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS). The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was launched as a Station Development Test Objective (SDTO) experiment to evaluate the suitability of CSPE technology for routine use monitoring water quality on the ISS. CSPE is a sorption-spectrophotometric technique that combines colorimetric reagents, solid-phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water samples. In CSPE, a known volume of sample is metered through a membrane disk that has been impregnated with an analyte-specific colorimetric reagent and any additives required to optimize the formation of the analyte-reagent complex. As the sample flows through the membrane disk, the target analyte is selectively extracted, concentrated, and complexed. Formation of the analyte-reagent complex causes a detectable change in the color of the membrane disk that is proportional to the amount of analyte present in the sample. The analyte is then quantified by measuring the color of the membrane disk surface using a hand-held diffuse reflectance spectrophotometer (DRS). The CWQMK provides the capability to measure the ionic silver (Ag +) and molecular iodine (I2) in water samples on-orbit. These analytes were selected for the evaluation of CSPE technology because they are the biocides used in the potable water storage and distribution systems on the ISS. Biocides are added to the potable water systems on spacecraft to inhibit microbial growth. On the United States (US) segment of the ISS molecular iodine serves as the biocide, while the Russian space agency utilizes silver as a biocide in their systems. In both cases, the biocides must be maintained at a level sufficient to control bacterial growth, but low enough to avoid any negative effects on crew health. For example, the

  2. Determination of six polyether antibiotic residues in foods of animal origin by solid phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Ha, Jing; Song, Ge; Ai, Lian-Feng; Li, Jian-Chen

    2016-04-01

    A new method using solid phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the determination of six polyether antibiotics, including lasalocid, salinomycin, monensin, narasin, madubamycin and nigericin residues, in foods of animal origin. The samples were extracted with acetonitrile and purified by ENVI-Carb SPE columns after comparing the impurity effect and maneuverability of several SPE cartridges. Subsequently, the analytes were separated on a Hypersil Gold column (2.1×150mm, 5μm) and analyzed by MS/MS detection. The limit of quantization (LOQ) for milk and chicken was 0.4μg/kg, and for chicken livers and eggs, it was 1μg/kg. The linearity was satisfactory with a correlation coefficient of >0.9995 at concentrations ranging from 2 to 100μg/L. The average recoveries of the analytes fortified at three levels ranged from 68.2 to 114.3%, and the relative standard deviations ranged from 4.5 to 12.1%. The method was suitable for quantitative analysis and confirmation of polyether antibiotic residues in foods of animal origin. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kolmonen, Marjo [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland) and Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland)]. E-mail: marjo.kolmonen@helsinki.fi; Leinonen, Antti [Doping Control Laboratory, United Laboratories Ltd., Helsinki (Finland); Pelander, Anna [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland); Ojanperae, Ilkka [Forensic Toxicology Division, Department of Forensic Medicine, University of Helsinki (Finland)

    2007-02-28

    A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, {beta}-blockers, narcotics, {beta}{sub 2}-adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.

  4. The Extraction and Determination of Ellagic Acid Content in the Peels of Six Iranian Pomegranates Cultivars Using a New Miniaturized Matrix Solid-Phase Dispersion Method

    Directory of Open Access Journals (Sweden)

    Fariba Nazari Serenjeh

    2017-03-01

    Full Text Available Background and Aim:The peels of six Iranian pomegranates (Punica granatum L. cultivars, as a traditional medicine, were treated with a new miniaturized matrix solid-phase dispersion (MSPD method for the HPLC determination of ellagic acid (EA. Materials and Methods:In the proposed method, only 10mg of the sample powder was ground and blended with an equal amount of C18 sorbent in an agate mortar. The use of the agate mortar with smooth surface facilitated the sample transfer into a cartridge and reduced the required amount of sample and sorbent. Micro volumes of dichloromethane, n-hexane and methanol were used as modifier, washing and elution solvents, respectively. The eluate was injected into an HPLC-UV system for the analysis. Results:Several factors such as the type and amount of dispersing sorbent, modifier, washing solvent and eluent were carefully studied and optimized. Six replicated analyses at the optimized conditions resulted in a recovery of 96.7% and a relative standard deviation of 5.87%. The proposed method was successfully applied to the extraction and determination of EA in the peels samples. Conclusion:According to the ultimate results, the MSPD method is an efficient technique for the quantitative extraction of EA from the peels of pomegranate. Malas cultivar has the highest amount (18.1 g kg-1 of ellagic acid content compared to the other studied pomegranate cultivars.

  5. Matrix supported tailored polymer for solid phase extraction of fluoride from variety of aqueous streams

    International Nuclear Information System (INIS)

    Thakur, Neha; Kumar, Sanjukta A.; Wagh, D.N.; Das, Sadananda; Pandey, Ashok K.; Kumar, Sangita D.; Reddy, A.V.R.

    2012-01-01

    Highlights: ► Th complexed with poly (bis[2-(methacryloyloxy)-ethyl]phosphate) as tailored polymer membranes. ► Membranes offered high capacity and selectivity for fluoride in aqueous media. ► Quantitative uptake (80 ± 5%) of fluoride. ► Fast sorption kinetics. ► Reusability of polymer membranes. - Abstract: Fluoride related health hazards (fluorosis) are a major environmental problem in many regions of the world. It affects teeth; skeleton and its accumulation over a long period can lead to changes in the DNA structure. It is thus absolutely essential to bring down the fluoride levels to acceptable limits. Here, we present a new inorganic–organic hybrid polymer sorbent having tailored fixed-sites for fluoride sorption. The matrix supported poly (bis[2-(methacryloyloxy)-ethyl]phosphate) was prepared by photo-initiator induced graft-polymerization in fibrous and microporous (sheet) host poly(propylene) substrates. These substrates were conditioned for selective fluoride sorption by forming thorium complex with phosphate groups on bis[2-methacryloyloxy)-ethyl] phosphate (MEP). These tailored sorbents were studied for their selectivity towards fluoride in aqueous media having different chemical conditions. The fibrous sorbent was found to take up fluoride with a faster rate (15 min for ≈76% sorption) than the sheet sorbent. But, the fluoride loading capacity of sheet sorbent (4320 mg kg −1 ), was higher than fibrous and any other sorbent reported in the literature so far. The sorbent developed in the present work was found to be reusable after desorption of fluoride using NaOH solution. It was tested for solid phase extraction of fluoride from natural water samples.

  6. Determination of Sr-90 in environmental samples using solid phase extraction disk

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood

    2002-01-01

    A method is described for determination of Sr-90 in environmental samples using solid phase extraction disk (Empore TM Strontium Rad Disk) and GM counter. To determine the optimum condition for capacity of Empore TM Strontium Rad Disk, its characterization studies such as the effects Sr content, acidity (molarity) of acids, presence of Ca 2+ and other major ions (Na + , Mg 2+ etc), influence of interference (Pb and Bi) and others were carried out. An optimized the using of Empore TM Strontium Rad Disk for determination of Sr-90 was validated by application to environmental samples. Quantitative recoveries above 95%for Sr (stable) were recorded in 6M HCl condition. Typical environmental samples may contain an assortment of anionic and cationic species, but in general, Empore TM Strontium Rad Disk has enough capacity to effectively separate Sr for wide variety of aqueous solutions. Sr recovery in a matrix-free or the content of matrix less than 300 mg/sample is typically greater than 99% is reported in this research work. In particular, sample, which may contain interference such as Pb and Bi would require an addition separation step before processing to ensure an accurate measurement of Sr. In this research work, radiotracer 85 Sr was used to monitor the behavior of Sr and calculation its recovery. For analytical methods that can count Y-90, the Sr-90 activity/concentration in environmental sample was calculated. The concentration of Sr-90 in ash sample (Quality Controled Sample) of 276 ± 18 Bq/kg ash was determined from Y-90 activity. The relative percent difference of 1.1% was achievable for Empore TM Sr-Rad Disk methods when compared to the conventional method (fumed-HNO 3 method) - 279 ± 11 Bq/kg ash. (Author)

  7. Novel approach to microwave-assisted extraction and micro-solid-phase extraction from soil using graphite fibers as sorbent.

    Science.gov (United States)

    Xu, Li; Lee, Hian Kee

    2008-05-30

    A single-step extraction-cleanup procedure involving microwave-assisted extraction (MAE) and micro-solid-phase extraction (micro-SPE) has been developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) from soil samples. Micro-SPE is a relatively new extraction procedure that makes use of a sorbent enclosed within a sealed polypropylene membrane envelope. In the present work, for the first time, graphite fiber was used as a sorbent material for extraction. MAE-micro-SPE was used to cleanup sediment samples and to extract and preconcentrate five PAHs in sediment samples prepared as slurries with addition of water. The best extraction conditions comprised of microwave heating at 50 degrees C for a duration of 20 min, and an elution (desorption) time of 5 min using acetonitrile with sonication. Using gas chromatography (GC)-flame ionization detection (FID), the limits of detection (LODs) of the PAHs ranged between 2.2 and 3.6 ng/g. With GC-mass spectrometry (MS), LODs were between 0.0017 and 0.0057 ng/g. The linear ranges were between 0.1 and 50 or 100 microg/g for GC-FID analysis, and 1 and 500 or 1000 ng/g for GC-MS analysis. Granular activated carbon was also used for the micro-SPE device but was found to be not as efficient in the PAH extraction. The MAE-micro-SPE method was successfully used for the extraction of PAHs in river and marine sediments, demonstrating its applicability to real environmental solid matrixes.

  8. Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection.

    Science.gov (United States)

    Kema, I P; Meijer, W G; Meiborg, G; Ooms, B; Willemse, P H; de Vries, E G

    2001-10-01

    Profiling of the plasma indoles tryptophan, 5-hydroxytryptophan (5-HTP), serotonin, and 5-hydroxyindoleacetic acid (5-HIAA) is useful in the diagnosis and follow-up of patients with carcinoid tumors. We describe an automated method for the profiling of these indoles in protein-containing matrices as well as the plasma indole concentrations in healthy controls and patients with carcinoid tumors. Plasma, cerebrospinal fluid, and tissue homogenates were prepurified by automated on-line solid-phase extraction (SPE) in Hysphere Resin SH SPE cartridges containing strong hydrophobic polystyrene resin. Analytes were eluted from the SPE cartridge by column switching. Subsequent separation and detection were performed by reversed-phase HPLC combined with fluorometric detection in a total cycle time of 20 min. We obtained samples from 14 healthy controls and 17 patients with metastasized midgut carcinoid tumors for plasma indole analysis. In the patient group, urinary excretion of 5-HIAA and serotonin was compared with concentrations of plasma indoles. Within- and between-series CVs for indoles in platelet-rich plasma were 0.6-6.2% and 3.7-12%, respectively. Results for platelet-rich plasma serotonin compared favorably with those obtained by single-component analysis. Plasma 5-HIAA, but not 5-HTP was detectable in 8 of 17 patients with carcinoid tumors. In the patient group, platelet-rich plasma total tryptophan correlated negatively with platelet-rich plasma serotonin (P = 0.021; r = -0.56), urinary 5-HIAA (P = 0.003; r = -0.68), and urinary serotonin (P manual, single-component analyses.

  9. Solid-phase/supercritical-fluid extraction for liquid chromatography of phenolic compounds in freshwater microalgae and selected cyanobacterial species

    Czech Academy of Sciences Publication Activity Database

    Klejdus, B.; Kopecký, Jiří; Benešová, L.; Vacek, J.

    2009-01-01

    Roč. 1216, č. 5 (2009), s. 763-771 ISSN 0021-9673 R&D Projects: GA ČR GA525/07/0338 Grant - others:CZ(CZ) GP525/08/P540 Institutional research plan: CEZ:AV0Z50200510 Keywords : methanol * solid-phase extraction * phenolic compounds Subject RIV: EE - Microbiology, Virology Impact factor: 4.101, year: 2009

  10. A new approach for cytokinin isolation from Arabidopsis tissues using miniaturized purification: pipette tip solid-phase extraction

    Czech Academy of Sciences Publication Activity Database

    Svačinová, Jana; Novák, Ondřej; Plačková, Lenka; Lenobel, René; Holík, Josef; Strnad, Miroslav; Doležal, Karel

    2012-01-01

    Roč. 8, _ (2012), s. 17 ISSN 1746-4811 R&D Projects: GA TA ČR TA01010861; GA AV ČR KAN200380801 Grant - others:GA MŠk(CZ) ED0007/01/01 Program:ED Institutional research plan: CEZ:AV0Z50380511 Keywords : Pipette tip solid-phase extraction (PT-SPE) * Arabidopsis thaliana * Cytokinins Subject RIV: EC - Immunology Impact factor: 2.667, year: 2012

  11. Imprinted magnetic graphene oxide for the mini-solid phase extraction of Eu (III) from coal mine area

    Science.gov (United States)

    Patra, Santanu; Roy, Ekta; Madhuri, Rashmi; Sharma, Prashant K.

    2017-05-01

    The present work represents the preparation of imprinted magnetic reduced graphene oxide and applied it for the selective removal of Eu (III) from local coal mines area. A simple solid phase extraction method was used for this purpose. The material shows a very high adsorption as well as removal efficiency towards Eu (III), which suggest that the material have potential to be used in future for their real time applications in removal of Eu (III) from complex matrices.

  12. Carbon nanotube-based benzyl polymethacrylate composite monolith as a solid phase extraction adsorbent and a stationary phase material for simultaneous extraction and analysis of polycyclic aromatic hydrocarbon in water.

    Science.gov (United States)

    Al-Rifai, Asma'a; Aqel, Ahmad; Wahibi, Lamya Al; ALOthman, Zeid A; Badjah-Hadj-Ahmed, Ahmed-Yacine

    2018-02-02

    A composite of multi-walled carbon nanotubes incorporated into a benzyl methacrylate-co-ethylene dimethacrylate porous monolith was prepared, characterized and used as solid phase adsorbent and as stationary phase for simultaneous extraction and separation of ten polycyclic aromatic hydrocarbons, followed by nano-liquid chromatography analysis. The extraction and chromatographic parameters were optimized with regard to the extraction efficiency and the quality of chromatographic analytes separation. Under the optimized conditions, all PAHs were separated in 13 min with suitable resolution values (Rs = 1.74-3.98). Addition of a small amount of carbon nanotubes (0.1% with respect to monomers) to the polymerization mixture increased the efficiency for the separation column to over 41,700 plates m -1 for chrysene at flow rate of 0.5 μL min -1 . The method showed a wide linear range (1-500 μg L -1 with R 2 more than 0.9938), acceptable extraction repeatability (RSDs extraction cartridges) and satisfactory detection limits (0.02-0.22 μg L -1 ). Finally, the proposed method was successfully applied to the detection of polycyclic aromatic hydrocarbons in environmental water samples. After a simple extraction procedure with preconcentration factor equal to 100, the average recovery values in ultra-pure, tap and sea water samples were found to be in the range 81.3-95.4% with %RSD less than 6.4. Again, the presence of carbon nanotubes (0.3% relatively to monomers) in native polymer enhanced the extraction performance for the solid phase adsorbent up to 78.4%. The application of the monoliths modified with CNTs in extraction and nano-scale liquid chromatography for analysis of environmental samples offered several advantages; it demonstrated an acceptable precision, low detection limits, good reproducibility, satisfying recoveries and wide dynamic linear ranges. Copyright © 2018. Published by Elsevier B.V.

  13. Method of analysis and quality-assurance practices for determination of pesticides in water by solid-phase extraction and capillary-column gas chromatography/mass spectrometry at the U.S. Geological Survey California District Organic Chemistry Laboratory, 1996-99

    Science.gov (United States)

    Crepeau, Kathryn L.; Baker, Lucian M.; Kuivila, Kathryn

    2000-01-01

    A method of analysis and quality-assurance practices were developed to study the fate and transport of pesticides in the San Francisco Bay-Estuary by the U.S. Geological Survey. Water samples were filtered to remove suspended-particulate matter and pumped through C-8 solid-phase extraction cartridges to extract the pesticides. The cartridges were dried with carbon dioxide and the pesticides were eluted with three cartridge volumes of hexane:diethyl ether (1:1) solution. The eluants were analyzed using capillary-column gas chromatography/mass spectrometry in full-scan mode. Method detection limits for pesticides ranged from 0.002 to 0.025 microgram per liter for 1-liter samples. Recoveries ranged from 44 to 140 percent for 25 pesticides in samples of organic-free reagent water and Sacramento-San Joaquin Delta and Suisun Bay water fortified at 0.05 and 0.50 microgram per liter. The estimated holding time for pesticides after extraction on C-8 solid-phase extraction cartridges ranged from 10 to 257 days.

  14. Humic acid-bonded silica as a novel sorbent for solid-phase extraction of benzo[a]pyrene in edible oils

    International Nuclear Information System (INIS)

    Luo Dan; Yu Qiongwei; Yin Hongrui; Feng Yuqi

    2007-01-01

    A novel solid-phase extraction (SPE) sorbent, humic acid-bonded silica (HAS), was prepared. Humic acids (HAs) were grafted onto silica matrices via an amide linkage between humyl chloride and the amido terminus of 3-aminopropyltrimethoxysilane (APTS)-silica gel. The resulting material was characterized by Fourier transform infrared spectrometer, elemental analysis, and nitrogen adsorption analysis. This sorbent exhibits an excellent adsorption capacity for some electron-abundant analytes owing to its peculiar structure. In this paper, we choose benzo[a]pyrene (BaP) in oil as a probe to validate the adsorption capacity of the material. Thus a fast, cheap and simple SPE method with humic acid-bonded silica cartridge for edible oil clean-up, followed by high-performance liquid chromatography (HPLC) with fluorescence detection was established. The effects of experimental variables, such as washing and elution solvents, and the amount of sorbents have been studied. The recoveries of BaP in edible oils spiked at 0.2-100 μg kg -1 were in the range of 78.8-102.7% with relative standard deviations ranging between 1.3 and 9.3%; the limit of detection was -0.06 μg kg -1

  15. Analyses of Indole Compounds in Sugar Cane (Saccharum officinarum L. Juice by High Performance Liquid Chromatography and Liquid Chromatography-Mass Spectrometry after Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Jean Wan Hong Yong

    2017-03-01

    Full Text Available Simultaneous quantitative analysis of 10 indole compounds, including indole-3-acetic acid (IAA, one of the most important naturally occurring auxins and some of its metabolites, by high performance liquid chromatography (HPLC and liquid chromatography-mass spectrometry (LC-MS after solid-phase extraction (SPE was reported for the first time. The analysis was carried out using a reverse phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid modified by methanol. Furthermore, a novel SPE procedure was developed for the pre-concentration and purification of indole compounds using C18 SPE cartridges. The combination of SPE, HPLC, and LC-MS was applied to screen for the indole compounds present in sugar cane (Saccharum officinarum L. juice, a refreshing beverage with various health benefits. Finally, four indole compounds were successfully detected and quantified in sugar cane juice by HPLC, which were further unequivocally confirmed by LC-MS/MS experiments operating in the multiple reaction monitoring (MRM mode.

  16. Pipette-tip solid-phase extraction using polypyrrole as efficient adsorbent for extraction of avermectins and milbemycins in milk.

    Science.gov (United States)

    Florez, Diego Hernando Ângulo; Teixeira, Roseane Andrade; da Silva, Ricky Cássio Santos; Pires, Bruna Carneiro; Dutra, Flávia Viana Avelar; Borges, Keyller Bastos

    2018-05-01

    In this work, we developed a HPLC method for the multidetermination of avermectins (AVM) (abamectin-ABA 1b and ABA 1a, eprinomectin-EPR, and ivermectin-IVM) and milbemycins (moxidectin-MOX) in milk samples using polypyrrole (PPy) as adsorbent material in pipette-tip solid-phase extraction (PT-PPy-SPE). PPy was characterized by scanning electron microscopy, thermogravimetric analysis, Fourier transform infrared spectroscopy, and X-ray diffraction and the data agreed with the literature. The sample preparation included the clean-up of the milk by protein precipitation (PP) with acetonitrile and extraction of the analytes by PT-PPy-SPE. The chromatographic method was developed in reverse phase and isocratic mode with flow rate at 1.2 mL min -1 and ultraviolet detection at 250 nm. The mobile phase composition was acetonitrile:methanol:water (55:25:20, v/v/v). The studied parameters and the optimized conditions for the sample preparation were washing solvent (300 μL water), volume and type of eluent (500 μL methanol), volume and pH of sample (1 mL and pH 10), amount of adsorbent material (50 mg PPy), and without addition of salt (NaCl). The method was linear over the concentration range from 20 to 3000 ng mL -1 with coefficients of correlation (r) ≥ 0.99 for all analytes and recoveries around 100%. The method developed and validated was used for the analyses of real milk samples from cow treated with Ivomec ® (IVM 3.5%), in which were found 21.51 ± 2.94 ng mL -1 of IVM. Finally, the results proved that PT-PPy-SPE coupled to HPLC-UV was economical, simple, and easy-to-perform technique. Graphical abstract Pipette-tip solid phase extraction using polypirrole as adsorbent material for determination of avermectins and milbemycins in milk.

  17. Determination of uranium and thorium isotopes by solid phase extraction and alpha spectrometry

    International Nuclear Information System (INIS)

    Kuruc, J.; Kovacova, M.; Strisovska, J.; Galanda, D.

    2013-01-01

    The aim of this work was to test the modified method suitable for the separation of isotopes of uranium and thorium samples of rocks, including gold ore and gold concentrate using of extraction chromatography method, after digestion of the sample, concentrating, separate the isotopes of uranium and thorium isotopes to prepare sources for the measurement of alpha spectra. Samples of rocks, gold ore and gold concentrate were digered in microwave decomposition in the environment of hydrogen peroxide and concentrated nitric acid. For the separation of uranium and thorium the vacuum box with cartridges DGA Resin and Resin(R) UTEVA (Triskem International, France) was used. Both sorbents allow separation of uranium from thorium. The results confirmed that the both sorbents give the same results within expanded uncertainty. The mass activity of monitored uranium and thorium radioisotopes was determined by alpha spectrometry method. The yields of separation were determined using uranium-232 as a tracer radionuclide; the activity of 232 U was 0.1438 Bq. Alpha spectra were measured on the Alpha spectrometer EG and G ORTEC 576A with the software MAESTRO, MCA Emulator and Gamma Vision-32 for Windows, USA. Mass activities of radionuclides were converted to mass concentration of isotopes 238 U, 234 U, 232 Th, 230 Th and 228 Th. The highest concentration of 238 U was sampled in granodiorite (Tunnel S-XIV-2, southwards, mining of Cu ore, not working there since 1990), where m( 238 U) = (0.81 ± 0.09) mg kg -1 (DGA Resin) and m( 238 U) = (0.90 ± 0.09) mg kg -1 (UTEVA(R) Resin), as well as m( 232 Th) = (18.8 ± 1.7) mg kg -1 (DGA Resin) and m( 232 Th) = (17.8 ± 1.5) mg kg -1 (UTEVA(R) Resin). In other samples of rocks, gold ore and gold concentrates have specific masses of isotopes of uranium and thorium two-to ten-folds lower. It can be concluded that the rocks, gold ores and concentrates of gold from the 'Rozalia' mine contain lower concentrations of uranium several times against

  18. Determination of clenbuterol in bovine liver by combining matrix solid phase dispersion and molecularly imprinted solid phase extraction followed by liquid chromatography/electrospray ion trap multiple stage mass spectrometry

    NARCIS (Netherlands)

    Crescenzi, C; Bayoudh, S; Cormack, P.A G; Klein, T; Ensing, K

    2001-01-01

    Matrix solid-phase dispersion(MSPD) is a new sample pretreatment for solid samples. This technique greatly simplifies sample pretreatment but, nonetheless, the extracts often still require an extra cleanup step that is both laborious and time-consuming. The potential;of combining MSPD with

  19. Molecularly imprinted solid-phase extraction for selective extraction of bisphenol analogues in beverages and canned food.

    Science.gov (United States)

    Yang, Yunjia; Yu, Jianlong; Yin, Jie; Shao, Bing; Zhang, Jing

    2014-11-19

    This study aimed to develop a selective analytical method for the simultaneous determination of seven bisphenol analogues in beverage and canned food samples by using a new molecularly imprinted polymer (MIP) as a sorbent for solid-phase extraction (SPE). Liquid chromatography coupled to triple-quadruple tandem mass spectrometry (LC-MS/MS) was used to identify and quantify the target analytes. The MIP-SPE method exhibited a higher level of selectivity and purification than the traditional SPE method. The developed procedures were further validated in terms of accuracy, precision, and sensitivity. The obtained recoveries varied from 50% to 103% at three fortification levels and yielded a relative standard deviation (RSD, %) of less than 15% for all of the analytes. The limits of quantification (LOQ) for the seven analytes varied from 0.002 to 0.15 ng/mL for beverage samples and from 0.03 to 1.5 ng/g for canned food samples. This method was used to analyze real samples that were collected from a supermarket in Beijing. Overall, the results revealed that bisphenol A and bisphenol F were the most frequently detected bisphenols in the beverage and canned food samples and that their concentrations were closely associated with the type of packaging material. This study provides an alternative method of traditional SPE extraction for screening bisphenol analogues in food matrices.

  20. Screening for Anabolic Steroids in Urine of Forensic Cases Using Fully Automated Solid Phase Extraction and LC–MS-MS

    DEFF Research Database (Denmark)

    Andersen, David Wederkinck; Linnet, Kristian

    2014-01-01

    and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids....... Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic...

  1. Characteristic of New Solid-Phase Extraction Sorbent: Activated Carbon Prepared from Rice Husks under Base Treated Condition

    OpenAIRE

    Afrida Kurnia Putri; Wang-Hsien Ding; Han-Wen Kuo

    2012-01-01

    A characterization of activated carbon (ACs) prepared from rice husks (RHs) under base treated condition as a new sorbent for solid-phase extraction (SPE) to extract 4-nonylphenol isomers (4-NPs) in water samples has been done. The ACs prepared from RHs usually exhibits low specific surface area due to its high ash content, but in case of its application for SPE, there are other factors need to be considered, such as the existence of functional groups inside the sorbent, that can enhance inte...

  2. Aptamer-functionalized Fe3 O4 magnetic nanoparticles as a solid-phase extraction adsorbent for the selective extraction of berberine from Cortex phellodendri.

    Science.gov (United States)

    Jiang, Ling-Feng; Chen, Bo-Cheng; Chen, Ben; Li, Xue-Jian; Liao, Hai-Lin; Zhang, Wen-Yan; Wu, Lin

    2017-07-01

    The extraction adsorbent was fabricated by immobilizing the highly specific recognition and binding of aptamer onto the surface of Fe 3 O 4 magnetic nanoparticles, which not only acted as recognition elements to recognize and capture the target molecule berberine from the extract of Cortex phellodendri, but also could favor the rapid separation and purification of the bound berberine by using an external magnet. The developed solid-phase extraction method in this work was useful for the selective extraction and determination of berberine in Cortex phellodendri extracts. Various conditions such as the amount of aptamer-functionalized Fe 3 O 4 magnetic nanoparticles, extraction time, temperature, pH value, Mg 2+ concentration, elution time and solvent were optimized for the solid-phase extraction of berberine. Under optimal conditions, the purity of berberine extracted from Cortex phellodendri was as high as 98.7% compared with that of 4.85% in the extract, indicating that aptamer-functionalized Fe 3 O 4 magnetic nanoparticles-based solid-phase extraction method was very effective for berberine enrichment and separation from a complex herb extract. The applicability and reliability of the developed solid-phase extraction method were demonstrated by separating berberine from nine different concentrations of one Cortex phellodendri extract. The relative recoveries of the spiked solutions of all the samples were between 95.4 and 111.3%, with relative standard deviations ranging between 0.57 and 1.85%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Liquid chromatography with tandem mass spectrometry for the determination of flufenoxuron in blood using automatic solid phase extraction and its application to a fatal case of flufenoxuron poisoning.

    Science.gov (United States)

    Rhee, Jongsook; Cho, Byungsuk; Lee, Juseon; Moon, Sungmin; Yum, Hyesun

    2015-12-01

    A liquid chromatography/tandem mass spectrometry method with solid phase extraction for the detection and the quantitation of flufenoxuron in an aliquot of blood was developed and validated. Flufenoxuron belongs to a benzoylurea insecticide and is the active ingredient of Cascade™. The analyte in postmortem specimens was extracted by solid-phase extraction with Bond Elut Certify cartridge. After the elution layer was evaporated, the residue was reconstituted with 70% methanol for LC/MS/MS analysis. Separations were carried out on a Synergi(®) 2.5u Fusion-RP 100 A column with column temperature kept at 40 °C at a flow rate of 0.4 mL/min. The mobile phase was composed of 5mM ammonium formate in 10% methanol and 5 mM ammonium formate in 90% methanol using gradient elution. A triple quadruple mass spectrometer equipped with an electrospray ionization source operated in a positive ion mode with selective reaction monitoring mode. Atrazine-d5 was used as internal standard. The assay was linear over 0.02-1.0 mg/L (r(2)=0.999). Limit of detection (LOD) and limit of quantitation (LOQ) in blood were 0.009 mg/L (S/N=3) and 0.02 mg/L (S/N=10), respectively. The accuracy and the precision were toxicology laboratory guidelines. Relative recoveries with 0.02, 0.1 and 1.0mg/L (in blood) were 112.3%, 101.2% and 111.0% (n=5), respectively. The developed method was applied in forensic toxicology to determine flufenoxuron in postmortem specimens in a fatal case of flufenoxuron intoxication in a 48-year-old-man who was found dead on bed in a small room after vomiting on the floor. The postmortem heart blood, peripheral blood and gastric contents were analyzed for flufenoxuron with the result of 6.3 mg/L in heart blood, 3.2 mg/L in peripheral blood and 30.6 mg/kg in gastric contents, respectively. The concentration ratio of the heart/peripheral blood of flufenoxuron was 2.0, and the ratio of gastric contents/peripheral blood was 9.4, suggesting possible postmortem redistribution and

  4. Determination of inorganic arsenic in algae using bromine halogenation and on-line nonpolar solid phase extraction followed by hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Zhang, Weihong; Qi, Yuehan; Qin, Deyuan; Liu, Jixin; Mao, Xuefei; Chen, Guoying; Wei, Chao; Qian, Yongzhong

    2017-08-01

    Accurate, stable and fast analysis of toxic inorganic arsenic (iAs) in complicated and arsenosugar-rich algae matrix is always a challenge. Herein, a novel analytical method for iAs in algae was reported, using bromine halogenation and on-line nonpolar solid phase extraction (SPE) followed by hydride generation atomic fluorescence spectrometry (HG-AFS). The separation of iAs from algae was first performed by nonpolar SPE sorbent using Br - for arsenic halogenation. Algae samples were extracted with 1% perchloric acid. Then, 1.5mL extract was reduced by 1% thiourea, and simultaneously reacted (for 30min) with 50μL of 10% KBr for converting iAs to AsBr 3 after adding 3.5mL of 70% HCl to 5mL. A polystyrene (PS) resin cartridge was employed to retain arsenicals, which were hydrolyzed, eluted from the PS resin with H 2 O, and categorized as iAs. The total iAs was quantified by HG-AFS. Under optimum conditions, the spiked recoveries of iAs in real algae samples were in the 82-96% range, and the method achieved a desirable limit of detection of 3μgkg -1 . The inter-day relative standard deviations were 4.5% and 4.1% for spiked 100 and 500μgkg -1 respectively, which proved acceptable for this method. For real algae samples analysis, the highest presence of iAs was found in sargassum fusiforme, followed by kelp, seaweed and laver. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A Rapid LC-HRMS Method for the Determination of Domoic Acid in Urine Using a Self-Assembly Pipette Tip Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Yiping Zhang

    2015-12-01

    Full Text Available In this study, we developed a self-assembly pipette tip solid-phase extraction (PTSPE method using a high molecular weight polymer material (PAX as the adsorbent for the determination of domoic acid (DA in human urine samples by liquid chromatography high-resolution mass spectrometry (LC-HRMS analysis. The PTSPE cartridge, assembled by packing 9.1 mg of PAX as sorbent into a 200 μL pipette tip, showed high adsorption capacity for DA owing to the strong cationic properties of PAX. Compared with conventional SPE, the PTSPE is simple and fast, and shows some advantages in the aspects of less solvent consumption, low cost, the absence of the evaporation step, and short time requirement. All the parameters influencing the extraction efficiency such as pH, the amount of sorbent, the number of aspirating/dispensing cycles, and the type and volume of eluent in PTSPE were carefully investigated and optimized. Under the optimized conditions, the limit of detection (LOD and limit of quantification (LOQ values of DA were 0.12 μg/L and 0.37 μg/L respectively. The extraction recoveries of DA from the urine samples spiked at four different concentrations were in a range from 88.4% to 102.5%. The intra- and inter-day precisions varied from 2.1% to 7.6% and from 2.6% to 12.7%, respectively. The accuracy ranged from −1.9% to −7.4%.

  6. A Rapid LC-HRMS Method for the Determination of Domoic Acid in Urine Using a Self-Assembly Pipette Tip Solid-Phase Extraction

    Science.gov (United States)

    Zhang, Yiping; Chen, Dawei; Hong, Zhuan

    2015-01-01

    In this study, we developed a self-assembly pipette tip solid-phase extraction (PTSPE) method using a high molecular weight polymer material (PAX) as the adsorbent for the determination of domoic acid (DA) in human urine samples by liquid chromatography high-resolution mass spectrometry (LC-HRMS) analysis. The PTSPE cartridge, assembled by packing 9.1 mg of PAX as sorbent into a 200 μL pipette tip, showed high adsorption capacity for DA owing to the strong cationic properties of PAX. Compared with conventional SPE, the PTSPE is simple and fast, and shows some advantages in the aspects of less solvent consumption, low cost, the absence of the evaporation step, and short time requirement. All the parameters influencing the extraction efficiency such as pH, the amount of sorbent, the number of aspirating/dispensing cycles, and the type and volume of eluent in PTSPE were carefully investigated and optimized. Under the optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) values of DA were 0.12 μg/L and 0.37 μg/L respectively. The extraction recoveries of DA from the urine samples spiked at four different concentrations were in a range from 88.4% to 102.5%. The intra- and inter-day precisions varied from 2.1% to 7.6% and from 2.6% to 12.7%, respectively. The accuracy ranged from −1.9% to −7.4%. PMID:26729165

  7. Electrospun UiO-66/polyacrylonitrile nanofibers as efficient sorbent for pipette tip solid phase extraction of phytohormones in vegetable samples.

    Science.gov (United States)

    Yan, Zhiming; Wu, Mei; Hu, Biqing; Yao, Minna; Zhang, Lan; Lu, Qiaomei; Pang, Jie

    2018-03-23

    In this work, metal-organic framework particles incorporated fibers (UiO-66/PAN nanofibers) were used as adsorbent in pipette tip solid phase extraction (PT-SPE) for the first time. The UiO-66/PAN nanofibers were fabricated by a facile electrospinning method and characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, X-ray diffraction and nitrogen adsorption-desorption experiments. The UiO-66/PAN nanofibers were applied to assemble a novel PT-SPE cartridge for determination of four phytohormones followed by high performance liquid chromatography (HPLC). Several experimental parameters such as kinds of UiO-66/PAN nanofibers, the amount of UiO-66/PAN nanofibers, the effect of solution pH, ionic strength and desorption conditions were intensively investigated. Under the optimal conditions, the linear ranges of the phytohormones were in the range of 0.06-60 ng/mL with correlation coefficients above 0.992. The limits of detection were between 0.01 ng/mL to 0.02 ng/mL. The interday and intraday precision (RSD) for three replicate extractions of the four phytohormones (15 ng/mL for each) was in the range of 1.5-5.6%. The established method was successfully applied for the determination of phytohormones in watermelon and mung bean sprouts samples. The results showed that the electrostatic interaction between the positively charged UiO-66 and anionic forms of phytohormones played an important role in the extraction of the phytohormones. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Ion-exchange solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the determination of veterinary drugs in organic fertilizers.

    Science.gov (United States)

    Zhao, Zhiyong; Zhang, Yanmei; Xuan, Yanfang; Song, Wei; Si, Wenshuai; Zhao, Zhihui; Rao, Qinxiong

    2016-06-01

    The analysis of veterinary drugs in organic fertilizers is crucial for an assessment of potential risks to soil microbial communities and human health. We develop a robust and sensitive method to quantitatively determine 19 veterinary drugs (amantadine, sulfonamides and fluoroquinolones) in organic fertilizers. The method involved a simple solid-liquid extraction step using the combination of acetonitrile and McIlvaine buffer as extraction solvent, followed by cleanup with a solid-phase extraction cartridge containing polymeric mixed-mode anion-exchange sorbents. Ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was used to separate and detect target analytes. We particularly focused on the optimization of sample clean-up step: different diluents and dilution factors were tested. The developed method was validated in terms of linearity, recovery, precision, sensitivity and specificity. The recoveries of all the drugs ranged from 70.9% to 112.7% at three concentration levels, with the intra-day and inter-day relative standard deviation lower than 15.7%. The limits of quantification were between 1.0 and 10.0μg/kg for all the drugs. Matrix effect was minimized by matrix-matched calibration curves. The analytical method was successfully applied for the survey of veterinary drugs contamination in 20 compost samples. The results indicated that fluoroquinolones had higher incidence rate and mean concentration levels ranging from 31.9 to 308.7μg/kg compared with other drugs. We expect the method will provide the basis for risk assessment of veterinary drugs in organic fertilizers. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. SIMPLE METHOD FOR ESTIMATING POLYCHLORINATED BIPHENYL CONCENTRATIONS ON SOILS AND SEDIMENTS USING SUBCRITICAL WATER EXTRACTION COUPLED WITH SOLID-PHASE MICROEXTRACTION. (R825368)

    Science.gov (United States)

    A rapid method for estimating polychlorinated biphenyl (PCB) concentrations in contaminated soils and sediments has been developed by coupling static subcritical water extraction with solid-phase microextraction (SPME). Soil, water, and internal standards are placed in a seale...

  10. Investigation of Di-ethylhexyl Phthalate Migration by Applying Magnetic Solid Phase Extraction Method Followed by GC-FID Determination

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-10-01

    Full Text Available Background and Objectives: The addition of plasticizers (mainly phthalates and adipates makes plastic flexible and popular for packaging, storing and preserving food, water, and so on. The most widely used plasticizer in food contact applications is di-ethylhexyl phthalate (DEHP though being suspected to have carcinogenic and estrogenic properties. The aim of this study is application of magnetic solid phase extraction as new absorbent for determination of DEHP in water samples by gas chromatography (GC. Materials and Methods: Important factors in extraction, separation and determination processes were optimized using the one-variable-at-a-time method. For optimization, all tests were performed two times. Figures of merit of the proposed method were evaluated. The amount of DEHP in some water samples was determined using the proposed method. Results: The results showed that the obtained chromatogram of extract was free of significant interference. The preservatives’ recoveries ranged from 91.6% to 102.2%. Limit of detection and limit of quantitation were 0.1 mg kg-1 and 0.3 µg L-1, respectively. Concentration of DEHP in the studied samples was in the range of N.D-2.3 µg L-1. Conclusions: The acceptable performance and reliability of the proposed method were demonstrated. Temperature and time were fount as the most effective parameters in migration of DEHP. Keywords: Di-ethylhexyl phthalate, Magnetic solid phase extraction, Migration, Gas chromatography

  11. Molecularly Imprinted Polymers (MIP for Selective Solid Phase Extraction of Celecoxib in Urine Samples Followed by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Saeedeh Ansari

    2017-09-01

    Full Text Available In this study, for the analysis of human urine samples, a novel method explained for the determination of celecoxib, a nonsteroidal anti-inflammatory drug (NSAID, using molecularly imprinted solid-phase extraction (MISPE coupled with high-performance liquid chromatography (HPLC. The synthesis of the MIP was performed by precipitation polymerization in methacrylic acid (MAA, ethylene glycol dimethacrylate (EGDMA, chloroform, 2,2′-azobisisobutyronitrile (AIBN and celecoxib as the functional monomer, cross-linker monomer, solvent, initiator and target drug, respectively. The celecoxib imprinted polymer was utilized as a specific sorbent for the solid phase extraction (SPE of celecoxib from samples. The molecularly imprinted polymer (MIP performance was compared with the synthesized non-molecularly imprinted polymer (NIP. Scanning electron microscopy (SEM, FT-IR spectroscopy, UV-VIS spectrophotometry and thermogravimetric analysis (TGA/DTG were used for characterizing the synthesized polymers. Moreover, the MISPE procedure parameters such as pH, eluent solvent flow rate, eluent volume and sorbent mass that probably influence the extraction process have been optimized to achieve the highest celecoxib extraction efficiency. The relative standard deviation (RSD %, recovery percent, limit of detection (LOD and limit of quantification (LOQ of this proposed method were 1.12%, 96%, 8 µg L-1 and 26.7 µg L-1, respectively. The proposed MISPE-HPLC-UV method can be used for the separation and enrichment of trace amounts of celecoxib in human urine and biological samples.

  12. New Methyltrimethoxysilane-(3-Mercaptopropyl)- Trimethoxysilane Coated Hollow Fiber-Solid Phase Micro extraction for Hexanal and Heptanal Analysis

    International Nuclear Information System (INIS)

    Siti Munirah Abd Wahib; Mohd Marsin Sanagi

    2016-01-01

    Determination of volatile organic compounds (VOCs) in various matrices is often accomplished using solid phase micro extraction (SPME) as a superior mode of extraction. Alternatively, another configuration of solid phase micro extraction (SPME) namely hollow fiber-solid phase micro extraction (HF-SPME) is a great approach to redress some limitations of the ordinary SPME fibers including fiber breakage, coating stripping and sample carry over. The HF-SPME technique highlights the use of hollow polypropylene (PP) membrane to hold and protect the adsorbent inside its lumen. Unlike the conventional SPME, the inexpensive HF device can be disposed after single use. Introducing extracting phase via sol-gel technology has gained great interest owing to its simple preparation method and promising way to obtain materials with good characteristics. In the present work, a new hybrid silica material based on methyltrimethoxysilane-(3-mercaptopropyl)trimethoxysilane (MTMOS-MPTMOS) was introduced as a new extractant of HF-SPME and the effectiveness of the proposed method was tested for analysis of hexanal and heptanal as the target VOC analytes. Preparation of the HF-SPME MTMOS-MPTMOS was simple in which the hybrid material was synthesized via sol-gel method and was self-polymerized in small segments of HF. Parameters affecting the efficiency of the HF-SPME MTMOS-MPTMOS in extracting both aldehydes were thoroughly investigated and analyzed by gas chromatography-flame ionization detection (GC-FID). It was found that the highest efficiency was achieved as the extraction was conducted in 30 min at a stirring rate of 1000 rpm in a 10 mL of sample solution whereby the back-extraction was performed via vortex for 3 min using 100 μL methanol as desorption solvent. Under the optimal conditions, linearity was observed over a range of 0.020-10.00 μg mL"-"1 with detection limits of 0.015 μg mL"-"1 and 0.010 μg mL"-"1 for hexanal and heptanal, respectively. The applicability of the HF

  13. Simple and fast analysis of tetrabromobisphenol A, hexabromocyclododecane isomers, and polybrominated diphenyl ethers in serum using solid-phase extraction or QuEChERS extraction followed by tandem mass spectrometry coupled to HPLC and GC.

    Science.gov (United States)

    Li, Jian; Chen, Tian; Wang, Yuwei; Shi, Zhixiong; Zhou, Xianqing; Sun, Zhiwei; Wang, Dejun; Wu, Yongning

    2017-02-01

    Two simplified sample preparation procedures for simultaneous extraction and clean-up of tetrabromobisphenol A, α-, β-, and γ-hexabromocyclododecane and polybrominated diphenyl ethers in human serum were developed and validated. The first procedure was based on solid-phase extraction. Sample extraction, purification, and lipid removal were carried out directly on an Oasis HLB cartridge. The second procedure was a quick, easy, cheap, effective, rugged, and safe-based approach using octadecyl-modified silica particles as a sorbent. After sample extraction and cleanup, tetrabromobisphenol A/hexabromocyclododecane was separated from polybrominated diphenyl ethers by using a Si-based cartridge. Tetrabromobisphenol A and hexabromocyclododecane were then detected by high-performance liquid chromatography coupled to tandem mass spectrometry, while polybrominated diphenyl ethers were detected by gas chromatography coupled to tandem mass spectrometry. The results of the spike recovery test using fetal bovine serum showed that the average recoveries of the analytes ranged from 87.3 to 115.3% with relative standard deviations equal to or lower than 13.4 %. Limits of detection of the analytes were in the range of 0.4-19 pg/mL except for decabromodiphenyl ether. The developed method was successfully applied to routine analysis of human serum samples from occupational workers and the general population. Extremely high serum polybrominated diphenyl ethers levels up to 3.32 × 10 4 ng/g lipid weight were found in occupational workers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A combination of solid-phase extraction and dispersive solid-phase extraction effectively reduces the matrix interference in liquid chromatography-ultraviolet detection during pyraclostrobin analysis in perilla leaves.

    Science.gov (United States)

    Farha, Waziha; Rahman, Md Musfiqur; Abd El-Aty, A M; Jung, Da-I; Kabir, Md Humayun; Choi, Jeong-Heui; Kim, Sung-Woo; Im, So Jeong; Lee, Young-Jun; Shin, Ho-Chul; Kwon, Chan-Hyeok; Son, Young-Wook; Lee, Kang-Bong; Shim, Jae-Han

    2015-12-01

    Perilla leaves contain many interfering substances; thus, it is difficult to protect the analytes during identification and integration. Furthermore, increasing the amount of sample to lower the detection limit worsens the situation. To overcome this problem, we established a new method using a combination of solid-phase extraction and dispersive solid-phase extraction to analyze pyraclostrobin in perilla leaves by liquid chromatography with ultraviolet absorbance detection. The target compound was quantitated by external calibration with a good determination coefficient (R(2) = 0.997). The method was validated (in triplicate) with three fortification levels, and 79.06- 89.10% of the target compound was recovered with a relative standard deviation <4. The limits of detection and quantification were 0.0033 and 0.01 mg/kg, respectively. The method was successfully applied to field samples collected from two different areas at Gwangju and Muan. The decline in the resiudue concentrations was best ascribed to a first-order kinetic model with half-lives of 5.7 and 4.6 days. The variation between the patterns was attributed to humidity. Copyright © 2015 John Wiley & Sons, Ltd.

  15. Magnetic metal-organic frameworks for fast and efficient solid-phase extraction of six Sudan dyes in tomato sauce.

    Science.gov (United States)

    Shi, Xin-Ran; Chen, Xue-Lei; Hao, Yu-Lan; Li, Li; Xu, Hou-Jun; Wang, Man-Man

    2018-06-01

    Magnetic solid-phase extraction is an effective and useful technique to preconcentrate trace analytes from food samples. In this study, a magnetic trimeric chromium octahedral metal-organic framework (Fe 3 O 4 -NH 2 @MIL-101) was fabricated and characterized. Fe 3 O 4 -NH 2 @MIL-101 was applied as an adsorbent of magnetic solid-phase extraction combined with high performance liquid chromatography to effectively isolate and simultaneously determine six Sudan dyes (Para Red, Sudan I-IV, and Sudan Red 7B) from tomato sauce. Potential factors affecting the MSPE were investigated in detail, and adsorption efficiency of Fe 3 O 4 -NH 2 @MIL-101 was compared with those of conventional adsorbents, such as neutral alumina, HLB, and C 18 . The developed method facilitated the extraction with using only 3 mg of adsorbent in 2 min. In addition, enhancement factors of 50, linear range of 0.01-25 μg/mL, and detection limit (S/N = 3) of 0.5-2.5 μg/kg were obtained. The intra-day and inter-day recoveries for spiked Sudan dyes were in the range of 72.6%-92.9% and 69.6%-91.6%, respectively, with relative standard deviations of ≤9.2%. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. [Simultaneous determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography].

    Science.gov (United States)

    Liu, Min; Li, Xiaolin; Bie, Wei; Wang, Minglin; Feng, Qian

    2011-02-01

    A new method was established for the determination of 15 industrial synthetic dyes in condiment by solid phase extraction-high performance liquid chromatography (SPE-HPLC). The samples were extracted by methanol-water (1:1, v/v) and purified by a solid phase extraction column. Then, the chromatographic separation was achieved on a Luna C18 column by linear gradient elution. The mobile phase was 10 mmol/L ammonium acetate-acetonitrile (containing 1% acetic acid). The results showed that the 15 industrial synthetic dyes can be separated efficiently. The recoveries of the 15 industrial synthetic dyes spiked in condiment were between 84.6% and 114.2% with the relative standard deviations of 0.9% - 10.3%. The limits of detection of this method was 0.05 - 0.18 mg/kg for the 15 industrial synthetic dyes. The method is simple, sensitive, accurate, repeatable and can be used for simultaneous determination of the 15 illegally added industrial synthetic dyes.

  17. Determination of Phthalate Plasticisers in Palm Oil Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC

    Directory of Open Access Journals (Sweden)

    Nazarudin Ibrahim

    2014-01-01

    Full Text Available Contamination of phthalates plasticisers to food has raised concern as some of the phthalates are suspected to be endocrine disruptors. The phthalates have high affinity with oily environment and analysing these chemicals in such matrices is difficult because of the trace amount of the analyte and interference from matrix. An online solid phase extraction (SPE technique using a large volume (3.5 mL injection was developed for the analysis of 6 common plasticisers in palm oil. A simple sample preparation involving alumina as a fat retainer and methanol : acetonitrile (1 : 1 as the extraction solvent was performed prior to the usage of online SPE-LC system. This system consists of two columns, C16 for the solid phase extraction (SPE and C18 as the analytical column, and a photo diode array detector. The calibration curves were linear from 5 to 1000 μg L−1, with correlation coefficients above 0.99. The instrumental limit of detection was 3 μg L−1 and satisfactory recovery was obtained. A screening on a few samples in the retail market revealed the presence of dibutyl phthalate (DBP and butylbenzylphthalate (BBP in the palm oil, with concentration less than 1 mg L−1.

  18. Automated microfluidic devices integrating solid-phase extraction, fluorescent labeling, and microchip electrophoresis for preterm birth biomarker analysis.

    Science.gov (United States)

    Sahore, Vishal; Sonker, Mukul; Nielsen, Anna V; Knob, Radim; Kumar, Suresh; Woolley, Adam T

    2018-01-01

    We have developed multichannel integrated microfluidic devices for automated preconcentration, labeling, purification, and separation of preterm birth (PTB) biomarkers. We fabricated multilayer poly(dimethylsiloxane)-cyclic olefin copolymer (PDMS-COC) devices that perform solid-phase extraction (SPE) and microchip electrophoresis (μCE) for automated PTB biomarker analysis. The PDMS control layer had a peristaltic pump and pneumatic valves for flow control, while the PDMS fluidic layer had five input reservoirs connected to microchannels and a μCE system. The COC layers had a reversed-phase octyl methacrylate porous polymer monolith for SPE and fluorescent labeling of PTB biomarkers. We determined μCE conditions for two PTB biomarkers, ferritin (Fer) and corticotropin-releasing factor (CRF). We used these integrated microfluidic devices to preconcentrate and purify off-chip-labeled Fer and CRF in an automated fashion. Finally, we performed a fully automated on-chip analysis of unlabeled PTB biomarkers, involving SPE, labeling, and μCE separation with 1 h total analysis time. These integrated systems have strong potential to be combined with upstream immunoaffinity extraction, offering a compact sample-to-answer biomarker analysis platform. Graphical abstract Pressure-actuated integrated microfluidic devices have been developed for automated solid-phase extraction, fluorescent labeling, and microchip electrophoresis of preterm birth biomarkers.

  19. Determination of chlorinated polycyclic aromatic hydrocarbons in water by solid-phase extraction coupled with gas chromatography and mass spectrometry.

    Science.gov (United States)

    Wang, Xianli; Kang, Haiyan; Wu, Junfeng

    2016-05-01

    Given the potential risks of chlorinated polycyclic aromatic hydrocarbons, the analysis of their presence in water is very urgent. We have developed a novel procedure for determining chlorinated polycyclic aromatic hydrocarbons in water based on solid-phase extraction coupled with gas chromatography and mass spectrometry. The extraction parameters of solid-phase extraction were optimized in detail. Under the optimal conditions, the proposed method showed wide linear ranges (1.0-1000 ng/L) with correlation coefficients ranging from 0.9952 to 0.9998. The limits of detection and the limits of quantification were in the range of 0.015-0.591 and 0.045-1.502 ng/L, respectively. Recoveries ranged from 82.5 to 102.6% with relative standard deviations below 9.2%. The obtained method was applied successfully to the determination of chlorinated polycyclic aromatic hydrocarbons in real water samples. Most of the chlorinated polycyclic aromatic hydrocarbons were detected and 1-monochloropyrene was predominant in the studied water samples. This is the first report of chlorinated polycyclic aromatic hydrocarbons in water samples in China. The toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in the studied tap water were 9.95 ng the toxic equivalency quotient m(-3) . 9,10-Dichloroanthracene and 1-monochloropyrene accounted for the majority of the total toxic equivalency quotients of chlorinated polycyclic aromatic hydrocarbons in tap water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Pyrolytic in situ magnetization of metal-organic framework MIL-100 for magnetic solid-phase extraction.

    Science.gov (United States)

    Huo, Shu-Hui; An, Hai-Yan; Yu, Jing; Mao, Xue-Feng; Zhang, Zhe; Bai, Lei; Huang, Yan-Feng; Zhou, Peng-Xin

    2017-09-29

    In this study, we report a facile, environmental friendly fabrication of a type of magnetic metal-organic framework (MOF) MIL-100 that can be used for magnetic solid-phase extraction (MSPE). The magnetic MOF composites were fabricated using in situ calcination method. The as-synthesized materials exhibited both high porosity and magnetic characteristics. They used for the MSPE of polycyclic aromatic hydrocarbons (PAHs) from water samples. Such MOF-based magnetic solid-phase extraction in combination with gas chromatography equipped with a flame ionization detector (GC-FID), exhibited wide linearity (0.02-250μgL -1 ), low detection limits (4.6-8.9ngL -1 ), and high enrichment factors (452-907) for PAHs. The relative standard deviations (RSDs) for intra- and inter-day extractions of PAHs were ranging from 1.7% to 9.8% and 3.8% to 9.2%, respectively. The recoveries for spiked PAHs (1μgL -1 ) in water samples were in the range of 88.5% to 106.6%. The results showed that the special anion-π orbital (electron donor-acceptor) interaction and π-π stacking between magnetic MIL-100 and PAHs play an important role in the adsorption of PAHs. Copyright © 2017. Published by Elsevier B.V.

  1. Determination of neonicotinoid pesticides residues in agricultural samples by solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Xie, Wen; Han, Chao; Qian, Yan; Ding, Huiying; Chen, Xiaomei; Xi, Junyang

    2011-07-15

    This work reports a new sensitive multi-residue liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detection, confirmation and quantification of six neonicotinoid pesticides (dinotefuran, thiamethoxam, clothiandin, imidacloprid, acetamiprid and thiacloprid) in agricultural samples (chestnut, shallot, ginger and tea). Activated carbon and HLB solid-phase extraction cartridges were used for cleaning up the extracts. Analysis is performed by LC-MS/MS operated in the multiple reaction monitoring (MRM) mode, acquiring two specific precursor-product ion transitions per target compound. Quantification was carried by the internal standard method with D(4)-labeled imidacloprid. The method showed excellent linearity (R(2)≥0.9991) and precision (relative standard deviation, RSD≤8.6%) for all compounds. Limits of quantification (LOQs) were 0.01 mg kg(-1) for chestnut, shallot, ginger sample and 0.02 mg kg(-1) for tea sample. The average recoveries, measured at three concentrations levels (0.01 mg kg(-1), 0.02 mg kg(-1) and 0.1 mg kg(-1) for chestnut, shallot, ginger sample, 0.02 mg kg(-1), 0.04 mg kg(-1) and 0.2 mg kg(-1) for tea sample), were in the range 82.1-108.5%. The method was satisfactorily validated for the analysis of 150 agricultural samples (chestnut, shallot, ginger and tea). Imidacloprid and acetamiprid were detected at concentration levels ranging from 0.05 to 3.6 mg kg(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  2. [18F]Fallypride: Metabolism studies and quantification of the radiotracer and its radiometabolites in plasma using a simple and rapid solid-phase extraction method

    International Nuclear Information System (INIS)

    Peyronneau, Marie-Anne; Saba, Wadad; Goutal, Sébastien; Kuhnast, Bertrand; Dollé, Frédéric; Bottlaender, Michel; Valette, Héric

    2013-01-01

    Introduction: [ 18 F]Fallypride, a fluorinated and substituted benzamide with high affinity for D 2 /D 3 receptors, is a useful PET radioligand for the study of striatal/extrastriatal areas. Since [ 18 F]fallypride is extensively metabolized in vivo and since PET examinations are long lasting in humans, the rapid measurement of the unchanged radiotracer in plasma is essential for the quantification of images. The present study aims: i) to evaluate if the radiometabolites of [ 18 F]fallypride cross the blood–brain barrier in rodents, ii) to identify these radiometabolites in baboon plasma and iii) to develop a rapid solid phase extraction method (SPE) suitable for human applications to quantify both [ 18 F]fallypride and its radiometabolites in plasma. Methods: The metabolites P450-dependant in rat and human liver microsomes were characterized by LC–MS–MS and compared to those detected in vivo. Sequential solvent elution on Oasis®-MCX-SPE cartridges was used to quantify [ 18 F]fallypride and its radiometabolites. Result: In rat microsomal incubations, five metabolites generated upon N/O-dealkylation or hydroxylation at the pyrrolidine and/or at the benzamide moiety were identified. No radiometabolite was detected in the rat brain. N-dealkylated and hydroxylated derivatives were detected in human microsomal incubations as well as in baboon plasma. The use of SPE (total recovery 100.2% ± 2.8%, extraction yield 95.5% ± 0.3%) allowed a complete separation of [ 18 F]fallypride from its radiometabolites in plasma and evaluate [ 18 F]fallypride at 150 min pi to be 22% ± 5% of plasma radioactivity. Conclusions: The major in vivo radiometabolites of [ 18 F]fallypride were produced by N-dealkylation and hydroxylation. Allowing the rapid analysis of multiple plasma samples, SPE is a method of choice for the determination of [ 18 F]fallypride until late images required for quantitative PET imaging in humans

  3. Molecularly imprinted polymer solid-phase extraction coupled to square wave voltammetry at carbon fibre microelectrodes for the determination of fenbendazole in beef liver.

    Science.gov (United States)

    Guzmán-Vázquez de Prada, A; Loaiza, Oscar A; Serra, B; Morales, D; Martínez-Ruiz, P; Reviejo, A J; Pingarrón, J M

    2007-05-01

    A molecularly imprinted polymer was developed and used for solid-phase extraction (MISPE) of the antihelmintic fenbendazole in beef liver samples. Detection of the analyte was accomplished using square wave voltammetry (SWV) at a cylindrical carbon fibre microelectrode (CFME). A mixture of MeOH/HAc (9:1) was employed both as eluent in the MISPE system and as working medium for electrochemical detection of fenbendazole. The limit of detection was 1.9x10(-7) mol L-1 (57 microg L-1), which was appropriate for the determination of fenbendazole at the maximum residue level permitted by the European Commission (500 microg kg-1 in liver). Given that the SW voltammetric analysis could not be directly performed in the sample extract as a consequence of interference from some sample components, a sample clean-up with a MIP for selectively retaining fenbendazole was performed. The MIP was synthesized using a 1:8:22 template/methacrylic acid/ethylene glycol dimethacrylate ratio. A Britton-Robinson Buffer of pH 9.0 was selected for retaining fenbendazole in the MIP cartridges, and an eluent volume of 5.0 mL at a flow rate of 2.0 mL min-1 was chosen in the elution step. Cross-reactivity with the MIP was observed for other benzimidazoles. The synthesized MIP exhibited a good selectivity for benzimidazoles with respect to other veterinary drugs. The applicability of the MISPE-SWV method was tested with beef liver samples, spiked with fenbendazole at 5,000 and 500 microg kg-1. Results obtained for ten different liver samples yielded mean recoveries of (95+/-12)% and (96+/-11)% for the upper and lower concentration level, respectively.

  4. Analysis of volatiles in silver carp by headspace solid phase micro-extraction coupled with GC-MS

    International Nuclear Information System (INIS)

    Yang Yuping; Xiong Guangquan; Cheng Wei; Liao Tao; Lin Ruotai; Geng Shengrong; Li Xin; Li Xiaoding; Wu Wenjin

    2010-01-01

    In this paper, a method for the determination of volatiles using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) was presented. The extraction conditions were optimized with reference to these volatiles as hexanal, heptanal, benzaldehyde, 1-Octen-3-ol, octanal, nonanal, decenal, 2,4-heptadienal and 2,4-decadienal. The extraction of fish muscle followed by incubation on a StableFlex divinyl benzene/Carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber during 50 in at 60 obtained the most effective extraction of the analytes. The methods by HS-SPME and GC-MS were effective in detecting volatiles in the gills, scales, viscera and fish muscles. The types of volatiles in the gill were more than other organs and the number of odors compounds was 63, and the number of volatiles in scales, viscera and fish muscles was 48, 44 and 42 respectively. (authors)

  5. Solid phase extraction and spectrophotometric determination of mercury in tobacco and tobacco additives with 5-(p-aminobenzylidene)-thiothiorhodanine

    International Nuclear Information System (INIS)

    Yang, Weizhu; Yang, Guangyu

    2006-01-01

    A highly sensitive, selective and rapid method for the determination of mercury based on the rapid reaction of mercury(II) with 5-(p-aminobenzylidene)-thiorhodanine (ABTR) and the solid phase extraction of the colored chelate with C 18 disks has been developed. At pH 3.5 and in the presence of emulsifier-OP medium, ABTR reacts with mercury(II) to form a red chelate of a 1:2 (mercury to ABTR) molar ratio. This chelate was enriched by solid phase extraction with C 18 disks and the retained chelate eluted form the disks with dimethyl formamide (DMF). An enrichment factor of 50 was achieved. In the DMF medium, the molar absorptivity of the chelate is 1.21 X 10 5 L mol -1 cm -1 at 545 nm, and Beer's law is obeyed in the 0.01∼3 μg mL -1 range in the measured solution. The relative standard deviation for eleven sample replicate measurements at the 0.01 μg mL -1 level is 1.7%. This method was applied to the determination of mercury in tobacco and tobacco additives and good preconcentration was found between proposed and comparative methods results. (author)

  6. [Determination of short chain chlorinated paraffins in leather products by solid phase extraction coupled with gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhang, Weiya; Wan, Xin; Li, Lixia; Wang, Chengyun; Jin, Shupei; Xing, Jun

    2014-10-01

    The short chain chlorinated paraffins (SCCPs) are the additives frequently used in the leather production in China, but they have been put into the list of forbidden chemicals issued by European Union recently. In fact, there is not a commonly recognized method for the determination of the SCCPs in the leather products due to the serious matrix interferences from the leather products and the complex chemical structures of the SCCPs. A method of solid phase extraction coupled with gas chromatography-mass spectrometry (SPE-GC-MS) was established for the determination of the SCCPs in the leather products after the optimization of the SPE conditions. It was found that the interferences from the leather products were thor- oughly separated from the analyte of the SCCPs on a home-made solid phase extraction (SPE) column filled with silica packing while eluted with a mixed solvent of n-hexane-methylene chloride (2:1, v/v). With this method, the recoveries for the SCCPs spiked in the real leather samples varied from 90.47% to 99.00% with the relative standard deviations (RSDs) less than 6.7%, and the limits of detection (LODs) were between 0.069 and 0.110 mg/kg. This method is suitable for qualitative and quantitative analysis of SCCPs in the leather products.

  7. Temperature sensitive molecularly imprinted microspheres for solid-phase dispersion extraction of malachite green, crystal violet and their leuko metabolites

    International Nuclear Information System (INIS)

    Tan, Lei; Chen, Kuncai; He, Rong; Peng, Rongfei; Huang, Cong

    2016-01-01

    This article demonstrates the feasibility of an alternative strategy for producing temperature sensitive molecularly imprinted microspheres (MIMs) for solid-phase dispersion extraction of malachite green, crystal violet and their leuko metabolites. Thermo-sensitive MIMs can change their structure following temperature stimulation. This allows capture and release of target molecules to be controlled by temperature. The fabrication technique provides surface molecular imprinting in acetonitrile using vinyl modified silica microspheres as solid supports, methacrylic acid and N-isopropyl acrylamide as the functional monomers, ethyleneglycol dimethacrylate as the cross-linker, and malachite green as the template. After elution of the template, the MIMs can be used for fairly group-selective solid phase dispersion extraction of malachite green, crystal violet, leucomalachite green, and leucocrystal violet from homogenized fish samples at a certain temperature. Following centrifugal separation of the microspheres, the analytes were eluted with a 95:5 mixture of acetonitrile and formic acid, and then quantified by ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) with isotope internal calibration. The detection limits for malachite green, crystal violet and their metabolites typically are 30 ng·kg −1 . Positive samples were identified by UHPLC-MS/MS in the positive ionization mode with multiple reaction monitoring. The method was applied to the determination of the dyes and the respective leuko dyes in fish samples, and accuracy and precision were validated by comparative analysis of the samples by using aluminum neutral columns. (author)

  8. A novel superparamagnetic surface molecularly imprinted nanoparticle adopting dummy template: an efficient solid-phase extraction adsorbent for bisphenol A.

    Science.gov (United States)

    Lin, Zhenkun; Cheng, Wenjing; Li, Yanyan; Liu, Zhiren; Chen, Xiangping; Huang, Changjiang

    2012-03-30

    Leakage of the residual template molecules is one of the biggest challenges for application of molecularly imprinted polymer (MIP) in solid-phase extraction (SPE). In this study, bisphenol F (BPF) was adopted as a dummy template to prepare MIP of bisphenol A (BPA) with a superparamagnetic core-shell nanoparticle as the supporter, aiming to avoid residual template leakage and to increase the efficiency of SPE. Characterization and test of the obtained products (called mag-DMIP beads) revealed that these novel nanoparticles not only had excellent magnetic property but also displayed high selectivity to the target molecule BPA. As mag-DMIP beads were adopted as the adsorbents of solid-phase extraction for detecting BPA in real water samples, the recoveries of spiked samples ranged from 84.7% to 93.8% with the limit of detection of 2.50 pg mL(-1), revealing that mag-DMIP beads were efficient SPE adsorbents. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Advanced analytical method of nereistoxin using mixed-mode cationic exchange solid-phase extraction and GC/MS.

    Science.gov (United States)

    Park, Yujin; Choe, Sanggil; Lee, Heesang; Jo, Jiyeong; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Jung, Jee H

    2015-07-01

    Nereistoxin(NTX) was originated from a marine annelid worm Lumbriconereis heteropoda and its analogue pesticides including cartap, bensultap, thiocyclam and thiobensultap have been commonly used in agriculture, because of their low toxicity and high insecticidal activity. However, NTX has been reported about its inhibitory neuro toxicity in human and animal body, by blocking nicotinic acetylcholine receptor and it cause significant neuromuscular toxicity, resulting in respiratory failure. We developed a new method to determine NTX in biological fluid. The method involves mixed-mode cationic exchange based solid phase extraction and gas chromatography/mass spectrometry for final identification and quantitative analysis. The limit of detection and recovery were substantially better than those of other methods using liquid-liquid extraction or headspace solid phase microextraction. The good recoveries (97±14%) in blood samples were obtained and calibration curves over the range 0.05-20 mg/L have R2 values greater than 0.99. The developed method was applied to a fatal case of cartap intoxication of 74 years old woman who ingested cartap hydrochloride for suicide. Cartap and NTX were detected from postmortem specimens and the cause of the death was ruled to be nereistoxin intoxication. The concentrations of NTX were 2.58 mg/L, 3.36 mg/L and 1479.7 mg/L in heart, femoral blood and stomach liquid content, respectively. The heart blood/femoral blood ratio of NTX was 0.76. Copyright © 2015. Published by Elsevier Ireland Ltd.

  10. Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hydrocarbons determination in water samples.

    Science.gov (United States)

    Mauri-Aucejo, Adela; Amorós, Pedro; Moragues, Alaina; Guillem, Carmen; Belenguer-Sapiña, Carolina

    2016-08-15

    Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and concentration influence have been evaluated. The experimental results indicate that the material possesses adsorption ability to the tested polycyclic aromatic hydrocarbons. Under the optimum conditions, the quantification limits of the method were in the range of 0.09-2.4μgL(-1) and fine linear correlations between peak height and concentration were found around 1.3-70μgL(-1). The method has good repeatability and reproducibility, with coefficients of variation under 8%. Due to the concentration results, this material may represent an alternative for trace analysis of polycyclic aromatic hydrocarbons in water trough solid-phase extraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A novel poly(deep eutectic solvent)-based magnetic silica composite for solid-phase extraction of trypsin

    International Nuclear Information System (INIS)

    Xu, Kaijia; Wang, Yuzhi; Li, Yixue; Lin, Yunxuan; Zhang, Haibao; Zhou, Yigang

    2016-01-01

    Novel poly(deep eutectic solvent) grafted silica-coated magnetic microspheres (Fe 3 O 4 @SiO 2 -MPS@PDES) were prepared by polymerization of choline chloride-itaconic acid (ChCl-IA) and γ-MPS-modified magnetic silica composites, and were characterized by vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FT-IR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA) and transmission electron microscope (TEM). Then the synthetic Fe 3 O 4 @SiO 2 -MPS@PDES microspheres were applied for the magnetic solid-phase extraction (MSPE) of trypsin for the first time. After extraction, the concentration of trypsin in the supernatant was determined by a UV–vis spectrophotometer. Single factor experiments were carried out to investigate the effects of the extraction process, including the concentration of trypsin, the ionic strength, the pH value, the extraction time and the temperature. Experimental results showed the extraction capacity could reach up to 287.5 mg/g under optimized conditions. In comparison with Fe 3 O 4 @SiO 2 -MPS, Fe 3 O 4 @SiO 2 -MPS@PDES displayed higher extraction capacity and selectivity for trypsin. According to the regeneration studies, Fe 3 O 4 @SiO 2 -MPS@PDES microspheres can be recycled six times without significant loss of its extraction capacity, and retained a high extraction capacity of 233 mg/g after eight cycles. Besides, the activity studies also demonstrated that the activity of the extracted trypsin was well retained. Furthermore, the analysis of real sample revealed that the prepared magnetic microspheres can be used to purify trypsin in crude bovine pancreas extract. These results highlight the potential of the proposed Fe 3 O 4 @SiO 2 -MPS@PDES-MSPE method in separation of biomolecules. - Highlights: • A strategy for solid-phase extraction of trypsin based on poly(deep eutectic solvent) modified magnetic silica microspheres. • Fe 3 O 4 @SiO 2 -MPS@PDES showed higher extraction capacity

  12. A novel poly(deep eutectic solvent)-based magnetic silica composite for solid-phase extraction of trypsin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Kaijia [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082 (China); Wang, Yuzhi, E-mail: wyzss@hnu.edu.cn [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082 (China); Li, Yixue; Lin, Yunxuan; Zhang, Haibao [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082 (China); Zhou, Yigang [Department of Microbiology, College of Basic Medicine, Central South University, Changsha, 410083 (China)

    2016-11-23

    Novel poly(deep eutectic solvent) grafted silica-coated magnetic microspheres (Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS@PDES) were prepared by polymerization of choline chloride-itaconic acid (ChCl-IA) and γ-MPS-modified magnetic silica composites, and were characterized by vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FT-IR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA) and transmission electron microscope (TEM). Then the synthetic Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS@PDES microspheres were applied for the magnetic solid-phase extraction (MSPE) of trypsin for the first time. After extraction, the concentration of trypsin in the supernatant was determined by a UV–vis spectrophotometer. Single factor experiments were carried out to investigate the effects of the extraction process, including the concentration of trypsin, the ionic strength, the pH value, the extraction time and the temperature. Experimental results showed the extraction capacity could reach up to 287.5 mg/g under optimized conditions. In comparison with Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS, Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS@PDES displayed higher extraction capacity and selectivity for trypsin. According to the regeneration studies, Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS@PDES microspheres can be recycled six times without significant loss of its extraction capacity, and retained a high extraction capacity of 233 mg/g after eight cycles. Besides, the activity studies also demonstrated that the activity of the extracted trypsin was well retained. Furthermore, the analysis of real sample revealed that the prepared magnetic microspheres can be used to purify trypsin in crude bovine pancreas extract. These results highlight the potential of the proposed Fe{sub 3}O{sub 4}@SiO{sub 2}-MPS@PDES-MSPE method in separation of biomolecules. - Highlights: • A strategy for solid-phase extraction of trypsin based on poly(deep eutectic solvent) modified magnetic silica

  13. MCX based solid phase extraction combined with liquid chromatography tandem mass spectrometry for the simultaneous determination of 31 endocrine-disrupting compounds in surface water of Shanghai.

    Science.gov (United States)

    Zhang, Hong-Chang; Yu, Xue-jun; Yang, Wen-chao; Peng, Jin-feng; Xu, Ting; Yin, Da-Qiang; Hu, Xia-lin

    2011-10-15

    A novel analytical method employing MCX (mixed-mode cationic exchange) based solid phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed to detect 31 endocrine-disrupting compounds (EDCs) in surface water samples simultaneously. The target EDCs belong to five classes, including seven estrogens, eight androgens, six progesterones, five adrenocortical hormones and five industrial compounds. In order to simultaneously concentrate the target EDCs and eliminate matrix interferences in the water samples, MCX SPE cartridges were employed for SPE, and then followed by a simple and highly efficient three-step sequential elution procedure. Two electrospray ionization (ESI) detection modes, positive (ESI+) and (ESI-), were optimized for HPLC-MS/MS analysis to obtain the highest sensitivity for all the EDCs. The limits of detection (LODs) were 0.02-1.9 ng L(-1), which are lower than or comparable to these reported in references. Wide linear ranges (LOD-100 ng L(-1) for ESI+ mode, and LOD-200 ng L(-1) for ESI- mode) were obtained with determination coefficients (R(2)) higher than 0.99 for all the compounds. With five internal standards, good recoveries (84.4-103.0%) of all the target compounds were obtained in selected surface water samples. The developed method was successfully applied to investigate the EDCs occurrence in the surface water of Shanghai by analyzing surface water samples from 11 sites. The results showed that nearly all the target compounds (30 in 31) were present in the surface water samples of Shanghai, of which three industrial compounds (4-t-OP, BPA, and BPF) showed the highest concentrations (median concentrations were 11.88-23.50 ng L(-1)), suggesting that industrial compounds were the dominating EDCs in the surface water of Shanghai, and much more attention should be paid on these compounds. Our present research demonstrated that SPE with MCX cartridges combined with HPLC-MS/MS was convenient

  14. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  15. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  16. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Determination of Five Major 8-Prenylflavones in Leaves of Epimedium by Solid-Phase Extraction Coupled with Capillary Electrophoresis

    Science.gov (United States)

    Xie, Juan-ping; Xiang, Ji-ming; Zhu, Zhong-liang

    2016-01-01

    A simple, accurate and reproducible method which is based on the capillary electrophoresis, coupled with solid-phase extraction, has been developed for simultaneous determination of multiple 8-prenylflavones from Chinese Herba Epimedii. In this study, the author has mainly illustrated the experimental process and research results of five major components including epimedin C, icariin, diphylloside A, epimedoside A and icarisoside A that have been extracted and identified from Herba Epimedii for the first time. Experimental conditions have been optimized to achieve the best separation efficiency for the following factors: the buffer pH, buffer concentration and applied voltage. The experiment can be conducted through two separable stages: the first stage is to obtain the crude extracts through the solid-phase extraction; and the second stage is to further separate five major components by using the capillary electrophoresis. The separation of the five components and the analysis of the experiment are relatively fast and can be completed within 20 min. The concentration ranges of the construction of standard curves of five major 8-prenylflavones are 32.0–395.0, 23.4–292.0, 42.1–526.0, 18.8–233.5 and 29.7–371.0 µg mL−1 respectively, which have showed acceptable linearity with a correlation coefficient, r ≥ 0.999. The coefficient varies within 2.0% for both intra- and inter-days tests. The recoveries of five components range from 92.3 to 104.1%. The relative standard deviations of recoveries of five components range from 1.2 and 2.8%. This new method will facilitate the extraction and expedite the determination of medical components from Herba Epimedii. PMID:26865656

  18. Identification of alkyl dimethylbenzylammonium surfactants in water samples by solid-phase extraction followed by ion trap LC/MS and LC/MS/MS

    Science.gov (United States)

    Ferrer, I.; Furlong, E.T.

    2001-01-01

    A novel methodology was developed for the determination of alkyl (C12, C14, and C16) dimethylbenzylammonium chloride (benzalkonium chloride or BAC, Chemical Abstract Service number: 8001-54-5) in water samples. This method is based on solid-phase extraction (SPE) using polymeric cartridges, followed by high-performance liquid chromatography/ion trap mass spectrometry (LC/MS) and tandem mass spectrometry(MS/MS) detection, equipped with an electrospray interface in positive ion mode. Chromatographic separation was achieved for three BAC homologues by using a C18 column and a gradient of acetonitrile/10 millimolar aqueous ammonium formate. Total method recoveries were higher than 71% in different water matrices. The main ions observed by LC/MS were at mass-to-charge ratios (m/z) of 304, 332, and 360, which correspond to the molecular ions of the C12, C14, and C16 alkyl BAC, respectively. The unequivocal structural identification of these compounds in water samples was performed by LC/MS/MS after isolation and subsequent fragmentation of each molecular ion. The main fragmentation observed for the three different homologues corresponded to the loss of the toluyl group in the chemical structure, which leads to the fragment ions at m/z 212, 240, and 268 and a tropylium ion, characteristic of all homologues, at m/z 91. Detection limits for the methodology developed in this work were in the low nanogram-per-liter range. Concentration levels of BAC - ranging from 1.2 to 36.6 micrograms per liter - were found in surface-water samples collected downstream from different wastewater-treatment discharges, thus indicating its input and persistence through the wastewater-treatment process.

  19. Rapid solid-phase extraction method to quantify [11C]-verapamil, and its [11C]-metabolites, in human and macaque plasma

    International Nuclear Information System (INIS)

    Unadkat, Jashvant D.; Chung, Francisco; Sasongko, Lucy; Whittington, Dale; Eyal, Sara; Mankoff, David; Collier, Ann C.; Muzi, Mark; Link, Jeanne

    2008-01-01

    Introduction: P-glycoprotein (P-gp), an efflux transporter, is a significant barrier to drug entry into the brain and the fetus. The positron emission tomography (PET) ligand, [ 11 C]-verapamil, has been used to measure in vivo P-gp activity at various tissue-blood barriers of humans and animals. Since verapamil is extensively metabolized in vivo, it is important to quantify the extent of verapamil metabolism in order to interpret such P-gp activity. Therefore, we developed a rapid solid-phase extraction (SPE) method to separate, and then quantify, verapamil and its radiolabeled metabolites in plasma. Methods: Using high-performance liquid chromatography (HPLC), we established that the major identifiable circulating radioactive metabolite of [ 11 C]-verapamil in plasma of humans and the nonhuman primate, Macaca nemestrina, was [ 11 C]-D-617/717. Using sequential and differential pH elution on C 8 SPE cartridges, we developed a rapid method to separate [ 11 C]-verapamil and [ 11 C]-D-617/717. Recovery was measured by spiking the samples with the corresponding nonradioactive compounds and assaying these compounds by HPLC. Results: Verapamil and D-617/717 recovery with the SPE method was >85%. When the method was applied to PET studies in humans and nonhuman primates, significant plasma concentration of D-617/717 and unknown polar metabolite(s) were observed. The SPE and the HPLC methods were not significantly different in the quantification of verapamil and D-617/717. Conclusions: The SPE method simultaneously processes multiple samples in less than 5 min. Given the short half-life of [ 11 C], this method provides a valuable tool to rapidly determine the concentration of [ 11 C]-verapamil and its [ 11 C]-metabolites in human and nonhuman primate plasma

  20. [Monitoring of the residue of fosthiazate in water samples using solid-phase extraction coupled with gas chromatography/mass spectrometry].

    Science.gov (United States)

    Zhu, Jing; Zhou, Xin; Fu, Chunmei; Liu, Sankang; Li, Zhangwan

    2004-11-01

    Solid-phase extraction (SPE) coupled with gas chromatography/mass spectrometry (GC/MS) was used to determine the fosthiazate residue in water samples. The water samples were first filtered through cellulose filters (0.45 microm pore size). A 100 mL volume of filtered water, in which 1 mL of methanol has been added, was then passed through a pre-conditioned 3 cm C18 cartridge at a flow-rate of 1.5 mL/min. Elution was performed by 1 mL of methanol. The eluant was finally dried under reduced pressure for solvent evaporation. The volume was quantitatively adjusted to 0.5 mL with methanol. The analysis was carried out on GC/MS. The mass spectrometer was operated in selected ion monitoring (SIM) mode. According to mass spectrum of fosthiazate, three selected ions at m/z of 126, 195, 283, respectively, were monitored for identification and quantification. High sensitivity and selectivity were achieved by using this method. The limit of detection for fosthiazate in water samples was determined to be 56.4 ng/L. The linearity was demonstrated over a wide range of concentrations covering from 0.282 to 141 microg/L. The recoveries were more than 85.5% and the relative standard deviations for the overall procedure were less than 4.42%. The fosthiazate residue was detected in the water samples from a pool near cropland where fosthiazate was used. The results demonstrate the suitability of the SPE-GC/MS approach for the analysis of fosthiazate in water.

  1. Rapid solid-phase extraction method to quantify [{sup 11}C]-verapamil, and its [{sup 11}C]-metabolites, in human and macaque plasma

    Energy Technology Data Exchange (ETDEWEB)

    Unadkat, Jashvant D. [Department of Pharmaceutics, University of Washington, Box 357610, Seattle, WA 98195 (United States)], E-mail: jash@u.washington.edu; Chung, Francisco; Sasongko, Lucy; Whittington, Dale; Eyal, Sara [Department of Pharmaceutics, University of Washington, Box 357610, Seattle, WA 98195 (United States); Mankoff, David [Department of Radiology, University of Washington, Box 356004, Seattle, WA 98195 (United States); Collier, Ann C. [Department of Medicine, University of Washington, Box 359929, Seattle, WA 98195 (United States); Muzi, Mark; Link, Jeanne [Department of Radiology, University of Washington, Box 356004, Seattle, WA 98195 (United States)

    2008-11-15

    Introduction: P-glycoprotein (P-gp), an efflux transporter, is a significant barrier to drug entry into the brain and the fetus. The positron emission tomography (PET) ligand, [{sup 11}C]-verapamil, has been used to measure in vivo P-gp activity at various tissue-blood barriers of humans and animals. Since verapamil is extensively metabolized in vivo, it is important to quantify the extent of verapamil metabolism in order to interpret such P-gp activity. Therefore, we developed a rapid solid-phase extraction (SPE) method to separate, and then quantify, verapamil and its radiolabeled metabolites in plasma. Methods: Using high-performance liquid chromatography (HPLC), we established that the major identifiable circulating radioactive metabolite of [{sup 11}C]-verapamil in plasma of humans and the nonhuman primate, Macaca nemestrina, was [{sup 11}C]-D-617/717. Using sequential and differential pH elution on C{sub 8} SPE cartridges, we developed a rapid method to separate [{sup 11}C]-verapamil and [{sup 11}C]-D-617/717. Recovery was measured by spiking the samples with the corresponding nonradioactive compounds and assaying these compounds by HPLC. Results: Verapamil and D-617/717 recovery with the SPE method was >85%. When the method was applied to PET studies in humans and nonhuman primates, significant plasma concentration of D-617/717 and unknown polar metabolite(s) were observed. The SPE and the HPLC methods were not significantly different in the quantification of verapamil and D-617/717. Conclusions: The SPE method simultaneously processes multiple samples in less than 5 min. Given the short half-life of [{sup 11}C], this method provides a valuable tool to rapidly determine the concentration of [{sup 11}C]-verapamil and its [{sup 11}C]-metabolites in human and nonhuman primate plasma.

  2. Halloysite Nanotubes as a New Adsorbent for Solid Phase Extraction and Spectrophotometric Determination of Iron in Water and Food Samples

    Science.gov (United States)

    Samadi, A.; Amjadi, M.

    2016-07-01

    Halloysite nanotubes (HNTs) have been introduced as a new solid phase extraction adsorbent for preconcentration of iron(II) as a complex with 2,2-bipyridine. The cationic complex is effectively adsorbed on the sorbent in the pH range of 3.5-6.0 and efficiently desorbed by trichloroacetic acid. The eluted complex has a strong absorption around 520 nm, which was used for determination of Fe(II). After optimizing extraction conditions, the linear range of the calibration graph was 5.0-500 μg/L with a detection limit of 1.3 μg/L. The proposed method was successfully applied for the determination of trace iron in various water and food samples, and the accuracy was assessed through the recovery experiments and analysis of a certified reference material (NIST 1643e).

  3. Magnetic nanoparticles modified with polydimethylsiloxane and multi-walled carbon nanotubes for solid-phase extraction of fluoroquinolones

    International Nuclear Information System (INIS)

    Xu, S.; Jiang, C.; Lin, Y.; Jia, L.

    2012-01-01

    We have surface-functionalized magnetic particles (MPs) with polydimethylsiloxane and multi-walled carbon nanotubes in a two-step reaction. The MPs were applied to solid-phase extraction of the fluoroquinolones ofloxacin, norfloxacin, ciprofloxacin, enrofloxacin prior to their determination by capillary liquid chromatography. The effects of sample pH, adsorption time, type of eluent, desorption time and desorption temperature were investigated. Under the optimum conditions, the extraction efficiencies are in the range from 81.5 % to 94.1 %, with relative standard deviations (RSDs) of -1 . The method was applied to the analysis of spiked mineral water and honey. The recoveries for the fluoroquinolones in the real samples range from 84.0 % to 112 %, with RSDs ranging from 2.9 % to 7.8 %. (author)

  4. Rapid Determination of Trace Palladium in Active Pharmaceutical Ingredients by Magnetic Solid-Phase Extraction and Flame Atomic Absorption Spectrometry

    Science.gov (United States)

    Yin, Q. H.; Zhu, D. M.; Yang, D. Z.; Hu, Q. F.; Yang, Y. L.

    2018-01-01

    Clutaraldehyde cross-linked magnetic chitosan nanoparticles were synthesized and used as an adsorbent for the dispersive solid-phase extraction of palladium in active pharmaceutical ingredients (APIs) prior to analysis by a flame atomic absorption spectrophotometer. FT-IR, X-ray diffraction, and TEM were used to characterize the adsorbent. Various parameters of experimental performance, such as adsorbent amount, pH, adsorption time, desorption solutions, coexisting ions, and adsorbent reusability, were investigated and optimized. Under the optimized conditions, good linearity was achieved in the 5.0-500 μg/L concentration range, with correlation coefficients of 0.9989. The limit of detection is 2.8 μg/L and the recoveries of spiked samples ranged from 91.7 to 97.6%. It was confirmed that the GMCNs nanocomposite was a promising adsorbing material for extraction and preconcentration of Pd in APIs.

  5. Matrix molecularly imprinted mesoporous sol-gel sorbent for efficient solid-phase extraction of chloramphenicol from milk.

    Science.gov (United States)

    Samanidou, Victoria; Kehagia, Maria; Kabir, Abuzar; Furton, Kenneth G

    2016-03-31

    Highly selective and efficient chloramphenicol imprinted sol-gel silica based inorganic polymeric sorbent (sol-gel MIP) was synthesized via matrix imprinting approach for the extraction of chloramphenicol in milk. Chloramphenicol was used as the template molecule, 3-aminopropyltriethoxysilane (3-APTES) and triethoxyphenylsilane (TEPS) as the functional precursors, tetramethyl orthosilicate (TMOS) as the cross-linker, isopropanol as the solvent/porogen, and HCl as the sol-gel catalyst. Non-imprinted sol-gel polymer (sol-gel NIP) was synthesized under identical conditions in absence of template molecules for comparison purpose. Both synthesized materials were characterized by Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR) and nitrogen adsorption porosimetry, which unambiguously confirmed their significant structural and morphological differences. The synthesized MIP and NIP materials were evaluated as sorbents for molecularly imprinted solid phase extraction (MISPE) of chloramphenicol in milk. The effect of critical extraction parameters (flow rate, elution solvent, sample and eluent volume, selectivity coefficient, retention capacity) was studied in terms of retention and desorption of chloramphenicol. Competition and cross reactivity tests have proved that sol-gel MIP sorbent possesses significantly higher specific retention and enrichment capacity for chloramphenicol compared to its non-imprinted analogue. The maximum imprinting factor (IF) was found as 9.7, whereas the highest adsorption capacity of chloramphenicol by sol-gel MIP was 23 mg/g. The sol-gel MIP was found to be adequately selective towards chloramphenicol to provide the necessary minimum required performance limit (MRPL) of 0.3 μg/kg set forth by European Commission after analysis by LC-MS even without requiring time consuming solvent evaporation and sample reconstitution step, often considered as an integral part in solid phase extraction work-flow. Intra and

  6. Rapid determination of the volatile components in tobacco by ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang

    2016-03-01

    An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. DNA purification using dynamic solid-phase extraction on a rotationally-driven polyethylene-terephthalate microdevice

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, K.R. [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Borba, J.C. [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos-SP (Brazil); Meija, M. [Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Mills, D.L. [TeGrex Technologies, Sperryville, VA 22740 (United States); Haverstick, D.M. [Department of Pathology, University of Virginia, Charlottesville, VA 22904 (United States); Olson, K.E.; Aranda, R. [Office of the Chief Scientist, Defense Forensic Science Center, N 31st Street, Atlanta, GA 30297 (United States); Garner, G.T. [Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Carrilho, E. [Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos-SP (Brazil); Landers, J.P., E-mail: landers@virginia.edu [Department of Chemistry, University of Virginia, Charlottesville, VA 22904 (United States); Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22904 (United States); Department of Pathology, University of Virginia, Charlottesville, VA 22904 (United States)

    2016-09-21

    We report the development of a disposable polyester toner centrifugal device for semi-automated, dynamic solid phase DNA extraction (dSPE) from whole blood samples. The integration of a novel adhesive and hydrophobic valving with a simple and low cost microfabrication method allowed for sequential addition of reagents without the need for external equipment for fluid flow control. The spin-dSPE method yielded an average extraction efficiency of ∼45% from 0.6 μL of whole blood. The device performed single sample extractions or accommodate up to four samples for simultaneous DNA extraction, with PCR-readiness DNA confirmed by effective amplification of a β-globin gene. The purity of the DNA was challenged by a multiplex amplification with 16 targeted amplification sites. Successful multiplexed amplification could routinely be obtained using the purified DNA collected post an on-chip extraction, with the results comparable to those obtained with commercial DNA extraction methods. This proof-of-principle work represents a significant step towards a fully-automated low cost DNA extraction device. - Highlights: • dSPE design on centrifugal PeT device with a unique mixing strategy was proposed. • Increased fluidic control with novel adhesive tape valves on a PeT device. • Multiplexed spin-dSPE device to run up to 4 samples simultaneously. • Demonstrated strong singleplexed and multiplexed amplification following chip dSPE.

  8. Determination of 15 polycyclic aromatic hydrocarbons in aquatic products by solid-phase extraction and GC-MS.

    Science.gov (United States)

    Liu, Qiying; Guo, Yuanming; Sun, Xiumei; Hao, Qing; Cheng, Xin; Zhang, Lu

    2018-02-22

    We propose a method for the simultaneous determination of 15 kinds of polycyclic aromatic hydrocarbons in marine samples (muscle) employing gas chromatography with mass spectrometry after saponification with ultrasound-assisted extraction and solid-phase extraction. The experimental conditions were optimized by the response surface method. In addition, the effects of different lyes and extractants on polycyclic aromatic hydrocarbons extraction were discussed, and saturated sodium carbonate was first used as the primary saponification reaction and extracted with 10 mL of ethyl acetate and secondly 1 mol/L of sodium hydroxide and 10 mL of n-hexane were used to achieve better results. The average recovery was 67-112%. Satisfactory data showed that the method has good reproducibility with a relative standard deviation of <13%. The detection limits of polycyclic aromatic hydrocarbons were 0.02-0.13 ng/g. Compared with other methods, this method has the advantages of simple pretreatment, low solvent consumption, maximum polycyclic aromatic hydrocarbons extraction, the fast separation speed, and the high extraction efficiency. It is concluded that this method meets the batch processing requirements of the sample and can also be used to determine polycyclic aromatic hydrocarbons in other high-fat (fish, shrimp, crab, shellfish) biological samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Solid phase speciation of arsenic by sequential extraction in standard reference materials and industrially contaminated soil samples

    International Nuclear Information System (INIS)

    Herreweghe, Samuel van; Swennen, Rudy; Vandecasteele, Carlo; Cappuyns, Valerie

    2003-01-01

    Leaching experiments, a mineralogical survey and larger samples are preferred when arsenic is present as discrete mineral phases. - Availability, mobility, (phyto)toxicity and potential risk of contaminants is strongly affected by the manner of appearance of elements, the so-called speciation. Operational fractionation methods like sequential extractions have been applied for a long time to determine the solid phase speciation of heavy metals since direct determination of specific chemical compounds can not always be easily achieved. The three-step sequential extraction scheme recommended by the BCR and two extraction schemes based on the phosphorus-like protocol proposed by Manful (1992, Occurrence and Ecochemical Behaviours of Arsenic in a Goldsmelter Impacted Area in Ghana, PhD dissertation, at the RUG) were applied to four standard reference materials (SRM) and to a batch of samples from industrially contaminated sites, heavily contaminated with arsenic and heavy metals. The SRM 2710 (Montana soil) was found to be the most useful reference material for metal (Mn, Cu, Zn, As, Cd and Pb) fractionation using the BCR sequential extraction procedure. Two sequential extraction schemes were developed and compared for arsenic with the aim to establish a better fractionation and recovery rate than the BCR-scheme for this element in the SRM samples. The major part of arsenic was released from the heavily contaminated samples after NaOH-extraction. Inferior extraction variability and recovery in the heavily contaminated samples compared to SRMs could be mainly contributed to subsample heterogeneity

  10. Preconcentration and separation of nickel, copper and cobalt using solid phase extraction and their determination in some real samples.

    Science.gov (United States)

    Ghaedi, M; Ahmadi, F; Soylak, M

    2007-08-17

    A solid phase extraction method has been developed to separate and concentrate trace amounts of nickel, cobalt and copper ions from aqueous samples for the measurement by flame atomic absorption spectrometry. By the passage of aqueous samples through activated carbon modified by dithioxamide (rubeanic acid) (DTO), Ni2+, Cu2+ and Co2+ ions adsorb quantitatively. The recoveries of analytes at pH 5.5 with 500 mg solid phase were greater than 95% without interference from alkaline, earth alkaline and some metal ions. The enrichment factor was 330. The detection limits by three sigma were 0.50 microg L(-1) for copper, 0.75 microg L(-1) for nickel and 0.80 microg L(-1) for cobalt. The loading capacity was 0.56 mg g(-1) for Ni2+, 0.50 mg g(-1) for Cu2+ and 0.47 mg g(-1) for Co2+. The presented procedure was applied to the determination of analytes in tap, river and sea waters, vegetable, soil and blood samples with successfully results (recoveries greater than 95%, R.S.D. lower than 2% for n=3).

  11. Preconcentration and separation of nickel, copper and cobalt using solid phase extraction and their determination in some real samples

    International Nuclear Information System (INIS)

    Ghaedi, M.; Ahmadi, F.; Soylak, M.

    2007-01-01

    A solid phase extraction method has been developed to separate and concentrate trace amounts of nickel, cobalt and copper ions from aqueous samples for the measurement by flame atomic absorption spectrometry. By the passage of aqueous samples through activated carbon modified by dithioxamide (rubeanic acid) (DTO), Ni 2+ , Cu 2+ and Co 2+ ions adsorb quantitatively. The recoveries of analytes at pH 5.5 with 500 mg solid phase were greater than 95% without interference from alkaline, earth alkaline and some metal ions. The enrichment factor was 330. The detection limits by three sigma were 0.50 μg L -1 for copper, 0.75 μg L -1 for nickel and 0.80 μg L -1 for cobalt. The loading capacity was 0.56 mg g -1 for Ni 2+ , 0.50 mg g -1 for Cu 2+ and 0.47 mg g -1 for Co 2+ . The presented procedure was applied to the determination of analytes in tap, river and sea waters, vegetable, soil and blood samples with successfully results (recoveries greater than 95%, R.S.D. lower than 2% for n = 3)

  12. Preconcentration and separation of nickel, copper and cobalt using solid phase extraction and their determination in some real samples

    Energy Technology Data Exchange (ETDEWEB)

    Ghaedi, M. [Chemistry Department, University of Yasouj, Yasouj 75914-353 (Iran, Islamic Republic of)]. E-mail: m_ghaedi@mail.yu.ac.ir; Ahmadi, F. [Gachsaran Azad University, Gachsaran (Iran, Islamic Republic of); Soylak, M. [Chemistry Department, University of Erciyes, 38039 Kayseri (Turkey)

    2007-08-17

    A solid phase extraction method has been developed to separate and concentrate trace amounts of nickel, cobalt and copper ions from aqueous samples for the measurement by flame atomic absorption spectrometry. By the passage of aqueous samples through activated carbon modified by dithioxamide (rubeanic acid) (DTO), Ni{sup 2+}, Cu{sup 2+} and Co{sup 2+} ions adsorb quantitatively. The recoveries of analytes at pH 5.5 with 500 mg solid phase were greater than 95% without interference from alkaline, earth alkaline and some metal ions. The enrichment factor was 330. The detection limits by three sigma were 0.50 {mu}g L{sup -1} for copper, 0.75 {mu}g L{sup -1} for nickel and 0.80 {mu}g L{sup -1} for cobalt. The loading capacity was 0.56 mg g{sup -1} for Ni{sup 2+}, 0.50 mg g{sup -1} for Cu{sup 2+} and 0.47 mg g{sup -1} for Co{sup 2+}. The presented procedure was applied to the determination of analytes in tap, river and sea waters, vegetable, soil and blood samples with successfully results (recoveries greater than 95%, R.S.D. lower than 2% for n = 3)

  13. Surfactant-enhanced liquid-liquid microextraction coupled to micro-solid phase extraction onto highly hydrophobic magnetic nanoparticles

    International Nuclear Information System (INIS)

    Giannoulis, Kiriakos M.; Giokas, Dimosthenis L.; Tsogas, George Z.; Vlessidis, Athanasios G.; Zhu, Qing; Pan, Qinmin

    2013-01-01

    We are presenting a simplified alternative method for dispersive liquid-liquid microextraction (DLLME) by resorting to the use of surfactants as emulsifiers and micro solid-phase extraction (μ-SPE). In this combined procedure, DLLME of hydrophobic components is initially accomplished in a mixed micellar/microemulsion extractant phase that is prepared by rapidly mixing a non-ionic surfactant and 1-octanol in aqueous medium. Then, and in contrast to classic DLLME, the extractant phase is collected by highly hydrophobic polysiloxane-coated core-shell Fe 2 O 3 (at)C magnetic nanoparticles. Hence, the sample components are the target analyte in the DLLME which, in turn, becomes the target analyte of the μ-SPE step. This 2-step approach represents a new and simple DLLME procedure that lacks tedious steps such as centrifugation, thawing, or delicate collection of the extractant phase. As a result, the analytical process is accelerated and the volume of the collected phase does not depend on the volume of the extraction solvent. The method was applied to extract cadmium in the form of its pyrrolidine dithiocarbamate chelate from spiked water samples prior to its determination by FAAS. Detection limits were brought down to the low μg L −1 levels by preconcentrating 10 mL samples with satisfactory recoveries (96.0–108.0 %). (author)

  14. Carbon nanotubes as adsorbent of solid-phase extraction and matrix for laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Pan, Chensong; Xu, Songyun; Zou, Hanfa; Guo, Zhong; Zhang, Yu; Guo, Baochuan

    2005-02-01

    A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 microL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized.

  15. Solid phase extraction using molecular imprinting polymers (MISPE for the determination of estrogens in surface water by HPLC

    Directory of Open Access Journals (Sweden)

    Viviane do Nascimento Bianchi

    2017-05-01

    Full Text Available Estrogens are emerging pollutants and traditional sewage treatments unable to remove them. They are harmful to human health and to the environment. It is therefore important to evaluate the presence and concentration of estrogens in water bodies and environmental matrices. This work presents the development and application of a methodology for the determination of E1, E3, EE2 and E2 in surface waters using solid phase extraction with molecular imprinting polymers (MISPE followed by identification and quantification by HPLC-DAD. Acetonitrile and water deionized acidified with phosphoric acid pH 3 (1:1, v/v, a flow rate of 1.0 ml min-1, at 40°C and an injection volume of 5 µL. The method was validated according to the protocol ICH Q2R. Reproducibility and repeatability tests resulted in a smaller variation coefficient of 10%; the calibration curves in the concentration ranged from 1 to 20 mg L-1, with return linearity values greater than 0.99. The limits of detection and quantification were less than 1 mg L-1 and the method was satisfactory for specificity and selectivity tests using caffeine, which is often found in water bodies receiving effluent, and DES, an estrogen used in the treatment of prostate cancer. Selected samples underwent clean-up and pre-concentration treatments using solid phase extraction with commercial phase (C18 and molecularly imprinted polymers (MISPE. The analysis of MISPE extracts indicate that it is possible to obtain results with greater sensitivity and precision for analyses of complex environmental matrices, demonstrating that the developed method can be applied in complex environmental matrices.

  16. Simultaneous analysis of nine aromatic amines in mainstream cigarette smoke using online solid-phase extraction combined with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Jie; Bai, Ruoshi; Zhou, Zhaojuan; Liu, Xingyu; Zhou, Jun

    2017-04-01

    A fully automated analytical method was developed and validated by this present study. The method was based on two-dimensional (2D) online solid-phase extraction liquid chromatography-tandem mass spectrometry (SPE-LC-MS/MS) to determine nine aromatic amines (AAs) in mainstream smoke (MSS) simultaneously. As a part of validation process, AAs yields for 16 top-selling commercial cigarettes from China market were evaluated by the developed method under both Health Canada Intensive (HCI) and ISO machine smoking regimes. The gas phase of MSS was trapped by 25 mL 0.6 M hydrochloric acid solution, while the particulate phase was collected on a glass fiber filter. Then, the glass fiber pad was extracted with hydrochloric acid solution in an ultrasonic bath. The extract was analyzed with 2D online SPE-LC-MS/MS. In order to minimize the matrix effects of sample on each analyte, two cartridges with different extraction mechanisms were utilized to cleanup disturbances of different polarity, which were performed by the 2D SPE. A phenyl-hexyl analytical column was used to achieve a chromatographic separation. Under the optimized conditions, the isomers of p-toluidine, m-toluidine and o-toluidine, 3-aminobiphenyl and 4-aminobiphenyl, and 1-naphthylamine and 2-naphthylamine were baseline separated with good peak shapes for the first time. The limits of detection for nine AAs ranged from 0.03 to 0.24 ng cig -1 . The recovery of the measurement of nine AAs was from 84.82 to 118.47%. The intra-day and inter-day precisions of nine AAs were less than 10 and 16%, respectively. Compared with ISO machine smoking regime, the AAs yields in MSS were 1.17 to 3.41 times higher under HCI machine smoking regime. Graphical abstract New method using online SPE-LC/MS/MS for analysis of aromatic amines in mainstream cigarette smoke.

  17. Mesoporous silica based MCM-41 as solid-phase extraction sorbent combined with micro-liquid chromatography-quadrupole-mass spectrometry for the analysis of pharmaceuticals in waters.

    Science.gov (United States)

    Dahane, S; Martínez Galera, M; Marchionni, M E; Socías Viciana, M M; Derdour, A; Gil García, M D

    2016-05-15

    This paper reports the first application of the silica based mesoporous material MCM-41 as a sorbent in solid phase extraction, to pre-concentrate pharmaceuticals of very different polarity (atenolol, nadolol, pindolol, timolol, bisoprolol, metoprolol, betaxolol, ketoprofen, naproxen, ibuprofen, diclofenac, tolfenamic acid, flufenamic acid and meclofenamic acid) in surface waters. The analytes were extracted from 100mL water samples at pH 2.0 (containing 10(-3) mol/L of sodium chloride) by passing the solution through a cartridge filled with 100 mg of MCM-41. Following elution, the pharmaceuticals were determined by micro-liquid chromatography and triple quadrupole-mass spectrometry. Two selected reaction monitoring transitions were monitored per compound, the most intense one being used for quantification and the second one for confirmation. Matrix effect was found in real waters for most analytes and was overcome using the standard addition method, which compared favorably with the matrix matched calibration method. The detection limits in solvent (acetonitrile:water 10:90, v/v) ranged from 0.01 to 1.48 μg/L and in real water extracts from 0.10 to 3.85 μg/L (0.001-0.0385 μg/L in the water samples). The quantitation limits in solvent were in the range 0.02-4.93 μg/L, whereas in real water extracts were between 0.45 and 10.00 μg/L (0.0045 and 0.1000 μg/L in the water samples). When ultrapure water samples were spiked at two concentration levels of each pharmaceutical (0.1 and 0.2 μg/L) and quantified using solvent based calibration graphs, recoveries were near 100%. However, recoveries for most pharmaceuticals were comparable or better than de described above, when river water samples (spiked at the same concentration levels) were quantified by the standard addition method and slightly worse using the matrix matched calibration method. Five real samples (two rivers, one dam and two fountain water samples) were analyzed by the developed method, atenolol

  18. Selective extraction of phospholipids from dairy products by micro-solid phase extraction based on titanium dioxide microcolumns followed by MALDI-TOF-MS analysis

    DEFF Research Database (Denmark)

    Calvano, Cosima; Jensen, Ole; Zambonin, Carlo

    2009-01-01

    A new micro-solid phase extraction (micro-SPE) procedure based on titanium dioxide microcolumns was developed for the selective extraction of phospholipids (PLs) from dairy products before matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) analysis. All...... the extraction steps (loading, washing, and elution) have been optimized using a synthetic mixture of PLs standard and the procedure was subsequently applied to food samples such as milk, chocolate milk and butter. The whole method demonstrated to be simpler than traditional approaches and it appears very...

  19. A novel poly(deep eutectic solvent)-based magnetic silica composite for solid-phase extraction of trypsin.

    Science.gov (United States)

    Xu, Kaijia; Wang, Yuzhi; Li, Yixue; Lin, Yunxuan; Zhang, Haibao; Zhou, Yigang

    2016-11-23

    Novel poly(deep eutectic solvent) grafted silica-coated magnetic microspheres (Fe 3 O 4 @SiO 2 -MPS@PDES) were prepared by polymerization of choline chloride-itaconic acid (ChCl-IA) and γ-MPS-modified magnetic silica composites, and were characterized by vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FT-IR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA) and transmission electron microscope (TEM). Then the synthetic Fe 3 O 4 @SiO 2 -MPS@PDES microspheres were applied for the magnetic solid-phase extraction (MSPE) of trypsin for the first time. After extraction, the concentration of trypsin in the supernatant was determined by a UV-vis spectrophotometer. Single factor experiments were carried out to investigate the effects of the extraction process, including the concentration of trypsin, the ionic strength, the pH value, the extraction time and the temperature. Experimental results showed the extraction capacity could reach up to 287.5 mg/g under optimized conditions. In comparison with Fe 3 O 4 @SiO 2 -MPS, Fe 3 O 4 @SiO 2 -MPS@PDES displayed higher extraction capacity and selectivity for trypsin. According to the regeneration studies, Fe 3 O 4 @SiO 2 -MPS@PDES microspheres can be recycled six times without significant loss of its extraction capacity, and retained a high extraction capacity of 233 mg/g after eight cycles. Besides, the activity studies also demonstrated that the activity of the extracted trypsin was well retained. Furthermore, the analysis of real sample revealed that the prepared magnetic microspheres can be used to purify trypsin in crude bovine pancreas extract. These results highlight the potential of the proposed Fe 3 O 4 @SiO 2 -MPS@PDES-MSPE method in separation of biomolecules. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Solid phase extraction of uranium and thorium on octadecyl bonded silica modified with Cyanex 302 from aqueous solutions

    International Nuclear Information System (INIS)

    Nilchi, A.; Shariati Dehaghan, T.; Rasouli Garmarodi, S.

    2013-01-01

    A simple and reliable method for rapid extraction and determination of uranium and thorium using octadecyl-bonded silica modified with Cyanex 302 is presented. Extraction efficiency and the influence of various parameters such as aqueous phase pH, flow rate of sample solution and amount of extractant has been investigated. The study showed that the extraction of uranium and thorium increase with increasing pH value and was found to be quantitative at pH 6; and the retention of ions was not affected significantly by the flow rate of sample solution. The extraction percent were found to be 89.55 and 86.27 % for uranium and thorium, respectively. The maximal capacity of the cartridges modified by 30 mg of Cyanex 302 was found to be 20 mg of uranium and thorium. The method was successfully applied to the extraction and determination of uranium and thorium in aqueous solutions. The percentage recovery of uranium and thorium in a number of natural as well as seawater samples of Iran were also investigated and found to be in the range of 85-95%. (author)

  1. Sol-gel titania-coated needles for solid phase dynamic extraction-GC/MS analysis of desomorphine and desocodeine.

    Science.gov (United States)

    Su, Chi-Ju; Srimurugan, Sankarewaran; Chen, Chinpiao; Shu, Hun-Chi

    2011-01-01

    Novel sol-gel titania film coated needles for solid-phase dynamic extraction (SPDE)-GC/MS analysis of desomorphine and desocodeine are described. The high thermal stability of titania film permits efficient extraction and analysis of poorly volatile opiate drugs. The influences of sol-gel reaction time, coating layer, extraction and desorption time and temperature on the SPDE needle performance were investigated. The deuterium labeled internal standard was introduced either during the extraction of analyte or directly injected to GC after the extraction process. The latter method was shown to be more sensitive for the analysis of water and urine samples containing opiate drugs. The proposed conditions provided a wide linear range (from 5-5000 ppb), and satisfactory linearity, with R(2) values from 0.9958 to 0.9999, and prominent sensitivity, LOQs (1.0-5.0 ng/g). The sol-gel titania film coated needle with SPDE-GC/MS will be a promising technique for desomorphine and desocodeine analysis in urine.

  2. Analysis of polycyclic aromatic hydrocarbons in vegetable oils combining gel permeation chromatography with solid-phase extraction clean-up

    DEFF Research Database (Denmark)

    Fromberg, Arvid; Højgård, A.; Duedahl-Olesen, Lene

    2007-01-01

    system equipped with a GPC column (S-X3) and pre-packed silica SPE columns for the subsequent clean-up and finally gas chromatography-mass spectrometry (GC-MS) determination. The method was validated for the determination of PAHs in vegetable oils and it can meet the criteria for the official control...... of benzo[a]pyrene levels in foods laid down by the Commission of the European Communities. A survey of 69 vegetable oils sampled from the Danish market included olive oil as well as other vegetable oils such as rapeseed oil, sunflower oil, grape seed oil and sesame oil. Levels of benzo[a]pyrene in all......A semi-automatic method for the determination of polycyclic aromatic hydrocarbons (PAHs) in edible oils using a combined gel permeation chromatography/solid-phase extraction (GPC/SPE) clean-up is presented. The method takes advantage of automatic injections using a Gilson ASPEC XL sample handling...

  3. Determination of enrofloxacin by room-temperature phosphorimetry after solid phase extraction on an acrylic polymer sorbent

    Science.gov (United States)

    de Souza, Cabrini F.; Martins, Renata K. S.; da Silva, Andrea R.; da Cunha, Alessandra L. M. C.; Aucélio, Ricardo Q.

    A phosphorimetric method was developed to enable the determination of enrofloxacin using photochemical derivatization which was used to both improve detection limits and to minimize the uncertainty of measurements. Phosphorescence was induced on cellulose containing TlNO3. Absolute limit of detection at the ng range and linear analytical response over three orders of magnitude were achieved. A metrological study was made to obtain the combined uncertainty value and to identify that the precision was mainly affected by the changing of substrates when measuring the signal from each replicate. Pharmaceutical formulations containing enrofloxacin were successfully analyzed by the method and the results were similar to the ones achieved using a HPLC method. A solid phase extraction on an acrylic polymer was optimized to separate enrofloxacin from interferents such as diclofenac and other components from biological matrices, which allowed the successful use of the method in urine analysis.

  4. Solid-Phase Extraction Strategies to Surmount Body Fluid Sample Complexity in High-Throughput Mass Spectrometry-Based Proteomics

    Science.gov (United States)

    Bladergroen, Marco R.; van der Burgt, Yuri E. M.

    2015-01-01

    For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations. PMID:25692071

  5. Separating DDTs in edible animal fats using matrix solid-phase dispersion extraction with activated carbon filter, Toyobo-KF.

    Science.gov (United States)

    Furusawa, Naoto

    2006-09-01

    A technique is presented for the economical, routine, and quantitative analysis of contamination by dichloro-diphenyl-trichloroethanes (DDTs) [pp'-DDT, pp'-dichlorodiphenyl dichloroethylene, and pp'-dichlorodiphenyl dichloreothane in beef tallow and chicken fat samples, based on their separation using matrix solid-phase dispersion (MSPD) extraction with Toyobo-KF, an activated carbon fiber. Toyobo-KF is a newly applied MSPD sorbent, and it is followed by reversed-phase high-performance liquid chromatography (HPLC) with a photodiode array detector. The resulting analytical performance parameters [recoveries of spiked DDTs (0.1, 0.2, and 0.4 microg/g) > or = 81%, with relative standard deviations of < or = 8% (n = 5), and quantitation limits < or = 0.03 microg/g], with minimal handling and cost-efficiency, indicate that the present MSPD-HPLC method may be a useful tool for routine monitoring of DDT contamination in meat.

  6. Robot-performed synthesis of [11C]CH3-methionine with isolation by means of solid-phase extraction

    International Nuclear Information System (INIS)

    Vasil'ev, D.A.; Kiselev, M.Yu.; Korsakov, M.V.; Khorti, A.G.

    1992-01-01

    Robot-performed technology of synthesizing radiopharmaceutical preparation 11 CH 3 -methionine, used in positron-emission tomography of brain to evaluate the rate of protein biosynthesis was developed. The technology is based on the synthesis of 11 CH 3 -methionine from[ 11 C]-CH I and DL-homocysteinethiolactone with subsequent isolation of the preparation by the method of solid-phase extraction. Activity of the preparation synthesized is 0.13-0.17 Ci, specific activity -325-850 Ci/mmol, total duration of the synthesis from the moment of irradiation end is 16-19 min, radiochemical yield, as regards 11 CH 3 I corrected for carbon-11 decay, is 60 %

  7. Extraction of acetanilides in rice using ionic liquid-based matrix solid phase dispersion-solvent flotation.

    Science.gov (United States)

    Zhang, Liyuan; Wang, Changyuan; Li, Zuotong; Zhao, Changjiang; Zhang, Hanqi; Zhang, Dongjie

    2018-04-15

    Ionic liquid-based matrix solid phase dispersion-solvent flotation coupled with high performance liquid chromatography was developed for the determination of the acetanilide herbicides, including metazachlor, propanil, alachlor, propisochlor, pretilachlor, and butachlor in rice samples. Some experimental parameters, including the type of dispersant, the mass ratio of dispersant to sample, pH of sample solution, the type of extraction solvent, the type of ionic liquid, flotation time, and flow rate of N 2 were optimized. The average recoveries of the acetanilide herbicides at spiked concentrations of 50, 125, and 250 µg/kg ranged from 89.4% to 108.7%, and relative standard deviations were equal to or lower than 7.1%, the limits of quantification were in the range of 38.0 to 84.7 µg/kg. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids.

    Science.gov (United States)

    Schellen, Anniek; Ooms, Bert; van de Lagemaat, Dick; Vreeken, Rob; van Dongen, William D

    2003-05-25

    A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS system were optimized in an integrated approach to maximize the application range and minimize the method development time. The optimized generic SPE-LC-MS/MS protocol was evaluated for 11 drugs with different physicochemical properties. Good quantification for 10 out of 11 of the pharmaceuticals in serum or plasma could be readily achieved. The quantitative assays gave recoveries better than 95%, lower quantification limits of 0.2-2.0 ng/ml, acceptable precision and accuracy and good linearity over 2-4 orders of magnitude. Carry-over was determined to be in the range of 0.02-0.10%, without optimization.

  9. Low-cost humic acid-bonded silica as an effective solid-phase extraction sorbent for convenient determination of aflatoxins in edible oils

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Neng-Zhi [Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi 530028 (China); Liu, Ping [School of Pharmaceutical Science, Guangxi Medical University, Nanning, Guangxi 530021 (China); Su, Xiao-Chuan; Liao, Yan-Hua; Lei, Ning-Sheng [Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi 530028 (China); Liang, Yong-Hong [School of Pharmaceutical Science, Guangxi Medical University, Nanning, Guangxi 530021 (China); Zhou, Shao-Huan; Lin, Wen-Si; Chen, Jie [Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi 530028 (China); Feng, Yu-Qi [Key Laboratory of Analytical Chemistry for Biology and Medicine, Ministry of Education, Department of Chemistry, Wuhan University, Wuhan 430072 (China); Tang, Yang, E-mail: tycarson2@163.com [Guangxi Zhuang Autonomous Region Center for Disease Prevention and Control, Nanning, Guangxi 530028 (China)

    2017-06-01

    Aflatoxins (AFs) are highly toxic, mutagenic, carcinogenic, and teratogenic secondary metabolites produced by the toxigenic fungi Aspergillus flavus and Aspergillus parasiticus. AFs tend to contaminate a wide range of foods which is a serious and recurring food safety problem worldwide. Currently, immunoaffinity chromatography (IAC) has become the most conventional sample clean-up method for determining AFs in foodstuffs. However, IAC method is limited in the large-scale food analysis because it requires the use of expensive disposable cartridges and the IA procedure is time-consuming. Herein, to achieve the cost-effective determination of AFs in edible oils, we developed a promising solid-phase extraction (SPE) method based on commercially available humic acid-bonded silica (HAS) sorbent, followed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) analysis. In HAS-SPE, AFs can be captured by the HAS sorbent with both hydrophobic and hydrophilic interactions, whereas the oil matrix was captured only with the hydrophobic interactions. The oil matrix can be sufficiently washed off with isopropanol, while the AFs were still retained on the SPE packing, thus achieving selective extraction of AFs and clean-up of oil matrices. Under the optimal conditions of HAS-SPE, satisfactory recoveries ranging from 82% to 106% for four AFs (B{sub 1}, B{sub 2}, G{sub 1}, and G{sub 2}) were achieved in various oil matrices, containing blended oil, tea oil, rapeseed oil, peanut oil, sunflower seed oil, corn oil, blended olive oil, rice oil, soybean oil, and sesame oil. Only minor matrix effects ranging from 99% to 105% for four AFs were observed. Moreover, the LODs of AFs between 0.012 and 0.035 μg/kg completely meet the regulatory levels fixed by the EU, China or other countries. The methodology was further validated for assaying the naturally contaminated peanut oils, and consistent results between the HAS-SPE and the referenced IAC were

  10. Chemically-modified activated carbon with ethylenediamine for selective solid-phase extraction and preconcentration of metal ions.

    Science.gov (United States)

    Li, Zhenhua; Chang, Xijun; Zou, Xiaojun; Zhu, Xiangbing; Nie, Rong; Hu, Zheng; Li, Ruijun

    2009-01-26

    A new method that utilizes ethylenediamine-modified activated carbon (AC-EDA) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The new sorbent was prepared by oxidative surface modification. Experimental conditions for effective adsorption of trace levels of Cr(III), Fe(III), Hg(II) and Pb(II) were optimized with respect to different experimental parameters using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4.0. Complete elution of absorbed metal ions from the sorbent surface was carried out using 3.0 mL of 2% (%w/w) thiourea and 0.5 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.4, 28.9, 60.5 and 49.9 mg g(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The time for 94% adsorption of target metal ions was less than 2 min. The detection limits of the method was found to be 0.28, 0.22, 0.09 and 0.17 ng mL(-1) for Cr(III), Fe(III), Hg(II) and Pb(II), respectively. The precision (R.S.D.) of the method was lower 4.0% (n=8). The prepared sorbent as solid-phase extractant was successfully applied for the preconcentration of trace Cr(III), Fe(III), Hg(II) and Pb(II) in natural and certified samples with satisfactory results.

  11. Study on the solid phase extraction and spectrophotometric determination of cobalt with 5-(2-benzothiazolylazo-8-hydroxyquinolene

    Directory of Open Access Journals (Sweden)

    Alaa S. Amin

    2014-11-01

    Full Text Available A highly sensitive, selective and rapid method for the determination of cobalt based on the rapid reaction of cobalt(II with 5-(2-benzothiazolylazo-8-hydroxyquinolene BTAHQ and the solid phase extraction of the Co(II-BTAHQ complex with C18 membrane disks were developed. In the presence of pH = 6.4 buffer solution and cetylpyridenium chloride (CPC medium, BTAHQ reacts with cobalt to form a deep violet complex with a molar ratio of 1:1 (cobalt to BTAHQ. This complex was enriched by the solid phase extraction with C18 membrane disks. An enrichment factor of 100 was obtained by elution of the complex from the disks with a minimal amount of isopentyl alcohol. In isopentyl alcohol medium, the molar absorptivity of the complex is 2.42 × 105 L mol−1 cm−1 at 658 nm. Beer’s law is obeyed in the range of 0.01–0.38 μg mL−1 in the measured solution. The relative standard deviation for 11 replicate samples of 0.20 μg mL−1 level is 1.37%. The detection and quantification limits reach 3.1 and 9.7 ng mL−1 in the original samples. This method was applied for the determination of cobalt in biological, water, soil and pharmaceutical preparation samples with good results.

  12. Dispersive solid phase extraction combined with ion-pair ultra high-performance liquid chromatography tandem mass spectrometry for quantification of nucleotides in Lactococcus lactis

    DEFF Research Database (Denmark)

    Magdenoska, Olivera; Martinussen, Jan; Thykær, Jette

    2013-01-01

    solid phase extraction with charcoal and subsequent analysis with ion-pair liquid chromatography coupled with electrospray ionization tandem mass spectrometry was established for quantification of intracellular pools of the 28 most important nucleotides. The method can handle extracts where cells leak...

  13. Streamlined sample cleanup using combined dispersive solid-phase extraction and in-vial filtration for analysis of pesticides and environmental pollutants in shrimp

    Science.gov (United States)

    A new method of sample preparation was developed and is reported for the first time. The approach combines in-vial filtration with dispersive solid-phase extraction (d-SPE) in a fast and convenient cleanup of QuEChERS (quick, easy, cheap, effective, rugged, and safe) extracts. The method was appli...

  14. Dual solid-phase and stir bar sorptive extraction combined with gas chromatography-mass spectrometry analysis provides a suitable tool for assaying limonene-derived mint aroma compounds in red wine.

    Science.gov (United States)

    Picard, Magali; Franc, Céline; de Revel, Gilles; Marchand, Stéphanie

    2018-02-25

    A novel analytical method was developed for quantitative determination of eight limonene-derived monoterpenes responsible for the mint aroma in red wine. As these aromatic compounds are present at trace levels, a new dual extraction approach was proposed, combining solid-phase extraction (SPE) and stir bar sorptive extraction (SBSE), followed by gas chromatography-mass spectrometry analysis. The various parameters affecting the efficiency of extracting the analytes from wine samples in both the SPE and SBSE steps were first investigated, to determine the best compromise for the simultaneous analysis of the compounds studied. Following preliminary optimization of the dilution factor, phase ratio, and methanol content in the SBSE sample, cartridge sorbent mass, type of solvent, elution volume, and wine sample volume in the pre-concentration SPE step were studied. Highest response values were obtained when a 90 mL wine sample was extracted on a 500 mg SPE C18 cartridge and eluted with 1.5 mL methanol. The wine extract was then diluted in 10 mL water to obtain a final methanol content of 15% before the SBSE step. Good linearity, repeatability, reproducibility, accuracy and the required low detection and quantification limits were obtained under the conditions described, making this SPE-SBSE combination a suitable, powerful tool for routine analysis of the selected limonene-derived mint aroma compounds in large series of wine samples. Finally, the validated method was applied to 15 commercial red Bordeaux wines, aged from 3 to 23 years. Most of the compounds studied, present within the ng.L -1 range, were easily quantified for the first time in wine. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Molecularly imprinted macroporous monoliths for solid-phase extraction: Effect of pore size and column length on recognition properties.

    Science.gov (United States)

    Vlakh, E G; Stepanova, M A; Korneeva, Yu M; Tennikova, T B

    2016-09-01

    The series of macroporous monolithic molecularly imprinted monoliths differed by pore size, column length (volume) and amount of template used for imprinting was synthesized using methacrylic acid and glycerol dimethacrylate as co-monomers and antibiotic ciprofloxacin as a template. The prepared monoliths were characterized regarding to their permeability, pore size, porosity, and resistance to the flow of a mobile phase. The surface morphology was also analyzed. The slight dependence of imprinting factor on flow rate, as well as its independence on pore size of macroporous molecularly imprinted monolithic media was observed. The column obtained at different conditions exhibited different affinity of ciprofloxacin to the imprinted sites that was characterized with Kdiss values in the range of 10(-5)-10(-4)M. The solid-phase extraction of ciprofloxacin from such biological liquids as human blood serum, human urine and cow milk serum was performed using the developed monolithic columns. In all cases, the extraction was found to be 95.0-98.6%. Additionally, the comparison of extraction of three fluoroqinolone analogues, e.g. ciprofloxacin, levofloxacin and moxifloxacin, from human blood plasma was carried out. Contrary to ciprofloxacin extracted with more than 95%, this parameter did not exceed 40% for its analogues. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Selective isolation of gonyautoxins 1,4 from the dinoflagellate Alexandrium minutum based on molecularly imprinted solid-phase extraction.

    Science.gov (United States)

    Lian, Ziru; Wang, Jiangtao

    2017-09-15

    Gonyautoxins 1,4 (GTX1,4) from Alexandrium minutum samples were isolated selectively and recognized specifically by an innovative and effective extraction procedure based on molecular imprinting technology. Novel molecularly imprinted polymer microspheres (MIPMs) were prepared by double-templated imprinting strategy using caffeine and pentoxifylline as dummy templates. The synthesized polymers displayed good affinity to GTX1,4 and were applied as sorbents. Further, an off-line molecularly imprinted solid-phase extraction (MISPE) protocol was optimized and an effective approach based on the MISPE coupled with HPLC-FLD was developed for selective isolation of GTX1,4 from the cultured A. minutum samples. The separation method showed good extraction efficiency (73.2-81.5%) for GTX1,4 and efficient removal of interferences matrices was also achieved after the MISPE process for the microalgal samples. The outcome demonstrated the superiority and great potential of the MISPE procedure for direct separation of GTX1,4 from marine microalgal extracts. Copyright © 2017. Published by Elsevier Ltd.

  17. Magnetic solid-phase extraction of tetracyclines using ferrous oxide coated magnetic silica microspheres from water samples.

    Science.gov (United States)

    Lian, Lili; Lv, Jinyi; Wang, Xiyue; Lou, Dawei

    2018-01-26

    A novel magnetic solid-phase extraction approach was proposed for extraction of potential residues of tetracyclines (TCs) in tap and river water samples, based on Fe 3 O 4 @SiO 2 @FeO magnetic nanocomposite. Characterized results showed that the received Fe 3 O 4 @SiO 2 @FeO had distinguished magnetism and core-shell structure. Modified FeO nanoparticles with an ∼5 nm size distribution were homogeneously dispersed on the surface of the silica shell. Owing to the strong surface affinity of Fe (II) toward TCs, the magnetic nanocomposite could be applied to efficiently extract three TCs antibiotics, namely, oxytetracycline, tetracycline and chlortetracycline from water samples. Several factors, such as sorbent amount, pH condition, adsorption and desorption time, desorption solvent, selectivity and sample volume, influencing the extraction performance of TCs were investigated and optimized. The developed method showed excellent linearity (R > 0.9992) in the range of 0.133-333 μg L -1 , under optimized conditions. The limits of detection were between 0.027 and 0.107 μg L -1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The feasibility of this method was evaluated by analysis of tap and river water samples. The recoveries at the spiked concentration levels ranged from 91.0% to 104.6% with favorable reproducibility (RSD < 4%). Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analysis of macrolide antibiotics in water by magnetic solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Pérez, Rosa Ana; Albero, Beatriz; Férriz, Macarena; Tadeo, José Luis

    2017-11-30

    Macrolides are one of the most commonly used families of antibiotics employed in human and veterinary treatment. These compounds are considered emerging contaminants with potential ecological and human health risks that could be present in surface water. This paper describes the development and application of a simple and efficient extraction procedure for the determination of tilmicosin; erythromycin, tylosin and erythromycin-H 2 O from water samples. Sample extraction was carried out using magnetic solid-phase extraction using oleate functionalized magnetic nanoparticles followed by LC-MS/MS analysis. The effects of several parameters on the extraction efficiency of MLs from water were evaluated. The recovery results obtained were >84% for most of the compounds, except for erytromycin. The LOD and LOQ values ranged from 11.5 to 26ngL -1 and from 34 to 77ngL -1 , respectively. The selected method was applied to monitor these contaminants in water samples from different sources. Tilmicosin and tylosin were not detected in any of the samples, but erythromycin and erythromycin-H 2 O were found in 50% of the surface water samples at levels from

  19. Solid-phase extraction element based on epoxy polymer monolith for determination of polar organic compounds in aqueous media.

    Science.gov (United States)

    Takahashi, Tadashi; Odagiri, Kayo; Watanabe, Atsushi; Watanabe, Chuichi; Kubo, Takuya; Hosoya, Ken

    2011-10-01

    A solid-phase extraction element based on epoxy polymer monolith was fabricated for sorptive enrichment of polar compounds from liquid and gaseous samples. After ultrasonication of the element in an aqueous solution for a given period of time, the thermal desorption (TD) using a pyrolyzer with gas chromatography/mass spectrometry (GC/MS), in which TD temperature was programmed from 50 to 250 °C for the analytes absorbed in the element, was used to evaluate the element for basic extraction performance using the aqueous standard mixtures consisting of compounds having varied polarities such as hexanol, isoamyl acetate, linalool, furfural and decanoic acid, in concentrations ranging from 10 μg/L to 1 mg/L. Excellent linear relationships were observed for all compounds in the standard mixture, except decanoic acid. In the extraction of beverages such as red wine, the extraction element showed stronger adsorption characteristics for polar compounds such as alcohols and acids than a non-polar polydimethylsiloxane-based element. This feature is derived from the main polymer structure along with hydroxyl and amino groups present in the epoxy-based monolith polymer matrix. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Magnetic solid phase extraction and static headspace gas chromatography-mass spectrometry method for the analysis of polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun

    2016-01-15

    A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Sulfonated nanocellulose for the efficient dispersive micro solid-phase extraction and determination of silver nanoparticles in food products.

    Science.gov (United States)

    Ruiz-Palomero, Celia; Soriano, M Laura; Valcárcel, Miguel

    2016-01-08

    This paper reports a simple approach to Analytical Nanoscience and Nanotechnology (AN&N) that integrates the nanotool, sulfonated nanocellulose (s-NC), and nanoanalyte, silver nanoparticles (AgNPs), in the same analytical process by using an efficient, environmentally friendly dispersive micro solid-phase extraction (D-μSPE) capillary electrophoresis (CE) method with s-NC as sorbent material. Introducing negatively charged sulfate groups onto the surface of cellulose enhances its surface chemistry and enables the extraction and preconcentration of AgNPs of variable diameter (10, 20 and 60nm) and shell composition (citrate and polyvinylpyrrolidone coatings) from complex matrices into a cationic surfactant. In this way, AgNPs of diverse nature were successfully extracted onto the s-NC sorbent and then desorbed into an aqueous solution containing thiotic acid (TA) prior to CE without the need for any labor-intensive cleanup. The ensuing eco-friendly D-μSPE method exhibited a linear response to AgNPs with a limit of detection (LOD) of 20μg/L. Its ability to specifically recognize AgNPs of different sizes was checked in orange juice and mussels, which afforded recoveries of 70.9-108.4%. The repeatability of the method at the limit of quantitation (LOQ) level was 5.6%. Based on the results, sulfonated nanocellulose provides an efficient, cost-effective analytical nanotool for the extraction of AgNPs from food products. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Iron oxide functionalized graphene nano-composite for dispersive solid phase extraction of chemical warfare agents from aqueous samples.

    Science.gov (United States)

    Chinthakindi, Sridhar; Purohit, Ajay; Singh, Varoon; Tak, Vijay; Goud, D Raghavender; Dubey, D K; Pardasani, Deepak

    2015-05-15

    Present study deals with the preparation and evaluation of graphene based magnetic nano-composite for dispersive solid phase extraction of Chemical Weapons Convention (CWC) relevant chemicals from aqueous samples. Nano-composite, Fe3O4@SiO2-G was synthesized by covalently bonding silica coated Fe3O4 onto the graphene sheets. Nerve agents (NA), Sulfur mustard (SM) and their non-toxic environmental markers were the target analytes. Extraction parameters like amount of sorbent, extraction time and desorption conditions were optimized. Dispersion of 20 milligram of sorbent in 200mL of water sample for 20min. followed by methanol/chloroform extraction produced average to good recoveries (27-94%) of targeted analytes. Recoveries of real agents exhibited great dependency upon sample pH and ionic strength. Sarin produced maximum recovery under mild acidic conditions (56% at pH 5) while VX demanded alkaline media (83% at pH 9). Salts presence in the aqueous samples was found to be advantageous, raising the recoveries to as high as 94% for SM. Excellent limits of detection (LOD) for sulphur mustard and VX (0.11ngmL(-1) and 0.19ngmL(-1) respectively) proved the utility of the developed method for the off-site analysis of CWC relevant chemicals. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Quantitative determination of sotolon, maltol and free furaneol in wine by solid-phase extraction and gas chromatography-ion-trap mass spectrometry.

    Science.gov (United States)

    Ferreira, Vicente; Jarauta, Idoia; López, Ricardo; Cacho, Juan

    2003-08-22

    A method for the analytical determination of sotolon [4,5-dimethyl-3-hydroxy-2(5H)-furanone], maltol [3-hydroxy-2-methyl-4H-pyran-4-one] and free furaneol [2,5-dimethyl-4-hydroxy-3(2H)-furanone] in wine has been developed. The analytes are extracted from 50 ml of wine in a solid-phase extraction cartridge filled with 800 mg of LiChrolut EN resins. Interferences are removed with 15 ml of a pentane-dichloromethane (20:1) solution, and analytes are recovered with 6 ml of dichloromethane. The extract is concentrated up to 0.1 ml and analyzed by GC-ion trap MS. Maltol and sotolon were determined by selected ion storage of ions in the m/z ranges 120-153 and 79-95, using the ions m/z 126 and 83 for quantitation, respectively. Furaneol was determined by non-resonant fragmentation of the m/z 128 mother ion and subsequent analysis of the m/z 81 ion. The detection limits of the method are in all cases between 0.5 and 1 microg l(-1), well below the olfactory thresholds of the compounds. The precision of the method is in the 4-5% range for levels in wine around 20 microg l(-1). Linearity holds at least up to 400 microg l(-1), and is satisfactory in all cases. The recoveries of maltol and sotolon are constant (70 and 64%, respectively) and do not depend on the type of wine. On the contrary, in the case of furaneol, red wines show constant and high recoveries (97%), while the recoveries on white wines range between 30 and 80%. Different experiments showed that this behavior is probably due to the existence of complexes formed between furaneol and sulphur dioxide or catechols. Sensory experiments confirmed that the complexed forms found in white wines are not perceived by orthonasal olfaction, and that the furaneol determined by the method can be considered as the free and odor-active fraction.

  4. Low-cost humic acid-bonded silica as an effective solid-phase extraction sorbent for convenient determination of aflatoxins in edible oils.

    Science.gov (United States)

    Zhou, Neng-Zhi; Liu, Ping; Su, Xiao-Chuan; Liao, Yan-Hua; Lei, Ning-Sheng; Liang, Yong-Hong; Zhou, Shao-Huan; Lin, Wen-Si; Chen, Jie; Feng, Yu-Qi; Tang, Yang

    2017-06-01

    Aflatoxins (AFs) are highly toxic, mutagenic, carcinogenic, and teratogenic secondary metabolites produced by the toxigenic fungi Aspergillus flavus and Aspergillus parasiticus. AFs tend to contaminate a wide range of foods which is a serious and recurring food safety problem worldwide. Currently, immunoaffinity chromatography (IAC) has become the most conventional sample clean-up method for determining AFs in foodstuffs. However, IAC method is limited in the large-scale food analysis because it requires the use of expensive disposable cartridges and the IA procedure is time-consuming. Herein, to achieve the cost-effective determination of AFs in edible oils, we developed a promising solid-phase extraction (SPE) method based on commercially available humic acid-bonded silica (HAS) sorbent, followed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) analysis. In HAS-SPE, AFs can be captured by the HAS sorbent with both hydrophobic and hydrophilic interactions, whereas the oil matrix was captured only with the hydrophobic interactions. The oil matrix can be sufficiently washed off with isopropanol, while the AFs were still retained on the SPE packing, thus achieving selective extraction of AFs and clean-up of oil matrices. Under the optimal conditions of HAS-SPE, satisfactory recoveries ranging from 82% to 106% for four AFs (B 1 , B 2 , G 1 , and G 2 ) were achieved in various oil matrices, containing blended oil, tea oil, rapeseed oil, peanut oil, sunflower seed oil, corn oil, blended olive oil, rice oil, soybean oil, and sesame oil. Only minor matrix effects ranging from 99% to 105% for four AFs were observed. Moreover, the LODs of AFs between 0.012 and 0.035 μg/kg completely meet the regulatory levels fixed by the EU, China or other countries. The methodology was further validated for assaying the naturally contaminated peanut oils, and consistent results between the HAS-SPE and the referenced IAC were obtained. In

  5. Magnetic graphene oxide modified with choline chloride-based deep eutectic solvent for the solid-phase extraction of protein.

    Science.gov (United States)

    Huang, Yanhua; Wang, Yuzhi; Pan, Qi; Wang, Ying; Ding, Xueqin; Xu, Kaijia; Li, Na; Wen, Qian

    2015-06-02

    Four kinds of green deep eutectic solvents (DESs) based on choline chloride (ChCl) have been synthesized and coated on the surface of magnetic graphene oxide (Fe3O4@GO) to form Fe3O4@GO-DES for the magnetic solid-phase extraction of protein. X-ray diffraction (XRD), vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FESEM) and thermal gravimetric analysis (TGA) were employed to characterize Fe3O4@GO-DES, and the results indicated the successful preparation of Fe3O4@GO-DES. The UV-vis spectrophotometer was used to measure the concentration of protein after extraction. Single factor experiments proved that the extraction amount was influenced by the types of DESs, solution temperature, solution ionic strength, extraction time, protein concentration and the amount of Fe3O4@GO-DES. Comparison of Fe3O4@GO and Fe3O4@GO-DES was carried out by extracting bovine serum albumin, ovalbumin, bovine hemoglobin and lysozyme. The experimental results showed that the proposed Fe3O4@GO-DES performs better than Fe3O4@GO in the extraction of acidic protein. Desorption of protein was carried out by eluting the solid extractant with 0.005 mol L(-1) Na2HPO4 contained 1 mol L(-1) NaCl. The obtained elution efficiency was about 90.9%. Attributed to the convenient magnetic separation, the solid extractant could be easily recycled. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Sol–gel-based silver nanoparticles-doped silica – Polydiphenylamine nanocomposite for micro-solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Habib, E-mail: bagheri@sharif.edu; Banihashemi, Solmaz

    2015-07-30

    A nanocomposite of silica-polydiphenylamine doped with silver nanoparticles (Ag–SiO{sub 2}-PDPA) was successfully synthesized by the sol–gel process. For its preparation, PDPA was mixed with butanethiol capped Ag nanoparticles (NPs) and added to the silica sol solution. The Ag NPs were stabilized as a result of their adsorption on the SiO{sub 2} spheres. The surface characteristic of nanocomposite was investigated using scanning electron microscopy (SEM). In this work the Ag–SiO{sub 2}-PDPA nanocomposite was employed as an efficient sorbent for micro-solid-phase extraction (μ-SPE) of some selected pesticides. An amount of 15 mg of the prepared sorbent was used to extract and determine the representatives from organophosphorous, organochlorine and aryloxyphenoxy propionic acids from aqueous samples. After the implementation of extraction process, the analytes were desorbed by methanol and determined using gas chromatography–mass spectrometry (GC–MS). Important parameters influencing the extraction and desorption processes such as pH of sample solution, salting out effect, type and volume of the desorption solvent, the sample loading and eluting flow rates along with the sample volume were experimentally optimized. Limits of detection (LODs) and the limits of quantification (LOQs) were in the range of 0.02–0.05 μg L{sup −1} and 0.1–0.2 μg L{sup −1}, respectively, using time scheduled selected ion monitoring (SIM) mode. The relative standard deviation percent (RSD %) with four replicates was in the range of 6–10%. The applicability of the developed method was examined by analyzing different environmental water samples and the relative recovery (RR %) values for the spiked water samples were found to be in the range of 86–103%. - Highlights: • A sol–gel-based silver nanoparticles doped silica-polydiphenylamine nanocomposite was synthesized. • The sorbent was applied to micro-solid-phase extraction of some selected pesticides in water

  7. Simultaneous determination of phenolic compounds in Equisetum palustre L. by ultra high performance liquid chromatography with tandem mass spectrometry combined with matrix solid-phase dispersion extraction.

    Science.gov (United States)

    Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie

    2014-11-01

    A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Polypyrrole-magnetite dispersive micro-solid-phase extraction combined with ultraviolet-visible spectrophotometry for the determination of rhodamine 6G and crystal violet in textile wastewater.

    Science.gov (United States)

    Kamaruddin, Amirah Farhan; Sanagi, Mohd Marsin; Wan Ibrahim, Wan Aini; Md Shukri, Dyia S; Abdul Keyon, Aemi S

    2017-11-01

    Polypyrrole-magnetite dispersive micro-solid-phase extraction method combined with ultraviolet-visible spectrophotometry was developed for the determination of selected cationic dyes in textile wastewater. Polypyrrole-magnetite was used as adsorbent due to its thermal stability, magnetic properties, and ability to adsorb Rhodamine 6G and crystal violet. Dispersive micro-solid-phase extraction parameters were optimized, including sample pH, adsorbent amount, extraction time, and desorption solvent. The optimum polypyrrole-magnetite dispersive micro-solid phase-extraction conditions were sample pH 8, 60 mg polypyrrole-magnetite adsorbent, 5 min of extraction time, and acetonitrile as the desorption solvent. Under the optimized conditions, the polypyrrole-magnetite dispersive micro-solid-phase extraction with ultraviolet-visible method showed good linearity in the range of 0.05-7 mg/L (R 2  > 0.9980). The method also showed a good limit of detection for the dyes (0.05 mg/L) and good analyte recoveries (97.4-111.3%) with relative standard deviations extraction and determination of dyes at trace concentration levels. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. N-nitrosodimethylamine in drinking water using a rapid, solid-phase extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S W.D. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Koester, C J [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Taguchi, V Y [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Wang, D T [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Palmentier, J P.F.P. [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch; Hong, K P [Ministery of Environment and Energy, Etobicoke, ON (Canada). Lab. Services Branch

    1995-12-01

    A simple, rapid method for the extraction of N-nitrosodimethylamine (NDMA) from drinking and surface waters was developed using Ambersorb 572. Development of an alternative method to classical liquid-liquid extraction techniques was necessary to handle the workload presented by implementation of a provincial guideline of 9 ppt for drinking water and a regulatory level of 200 ppt for effluents. A granular absorbent, Ambersorb 572, was used to extract the NDMA from the water in the sample bottle. The NDMA was extracted from the Ambersorb 572 with dichloromethane in the autosampler vial. Method characteristics include a precision of 4% for replicate analyses, and accuracy of 6% at 10 ppt and a detection limit of 1.0 ppt NDMA in water. Comparative data between the Ambersorb 572 method and liquid-liquid extraction showed excellent agreement (average difference of 12%). With the Ambersorb 572 method, dichloromethane use has been reduced by a factor of 1,000 and productivity has been increased by a factor of 3-4. Monitoring of a drinking water supply showed rapidly changing concentrations of NDMA from day to day. (orig.)

  10. Solid-phase extraction-spectrophotometric determination of uranium(VI) in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, Susan; Mohammadzadeh, Darush [Department of Chemistry, University of Birjand, Birjand (Iran); Yamini, Yadollah [Department of Chemistry, Tarbiat Moddars University, Tehran (Iran)

    2003-03-01

    A method for the extraction and determination of uranyl ion in natural waters using octadecyl bonded silica membrane disks modified with piroxicam and spectrophotometry with arsenazo(III) is proposed. The perconcentration step was studied with regard to experimental parameters such as amount of extractant, type and amount of eluent, pH, flow rates and tolerance limit of diverse ions on the recovery of uranyl ion. The limit of detection of the proposed method is 0.4 {mu}g L{sup -1} of uranyl. The method was applied to the recovery of uranyl from different water samples. (orig.)

  11. Solid-phase extraction-spectrophotometric determination of uranium(VI) in natural waters

    International Nuclear Information System (INIS)

    Sadeghi, Susan; Mohammadzadeh, Darush; Yamini, Yadollah

    2003-01-01

    A method for the extraction and determination of uranyl ion in natural waters using octadecyl bonded silica membrane disks modified with piroxicam and spectrophotometry with arsenazo(III) is proposed. The perconcentration step was studied with regard to experimental parameters such as amount of extractant, type and amount of eluent, pH, flow rates and tolerance limit of diverse ions on the recovery of uranyl ion. The limit of detection of the proposed method is 0.4 μg L -1 of uranyl. The method was applied to the recovery of uranyl from different water samples. (orig.)

  12. Matrix molecularly imprinted mesoporous sol–gel sorbent for efficient solid-phase extraction of chloramphenicol from milk

    International Nuclear Information System (INIS)

    Samanidou, Victoria; Kehagia, Maria; Kabir, Abuzar; Furton, Kenneth G.

    2016-01-01

    Highly selective and efficient chloramphenicol imprinted sol–gel silica based inorganic polymeric sorbent (sol–gel MIP) was synthesized via matrix imprinting approach for the extraction of chloramphenicol in milk. Chloramphenicol was used as the template molecule, 3-aminopropyltriethoxysilane (3-APTES) and triethoxyphenylsilane (TEPS) as the functional precursors, tetramethyl orthosilicate (TMOS) as the cross-linker, isopropanol as the solvent/porogen, and HCl as the sol–gel catalyst. Non-imprinted sol–gel polymer (sol–gel NIP) was synthesized under identical conditions in absence of template molecules for comparison purpose. Both synthesized materials were characterized by Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR) and nitrogen adsorption porosimetry, which unambiguously confirmed their significant structural and morphological differences. The synthesized MIP and NIP materials were evaluated as sorbents for molecularly imprinted solid phase extraction (MISPE) of chloramphenicol in milk. The effect of critical extraction parameters (flow rate, elution solvent, sample and eluent volume, selectivity coefficient, retention capacity) was studied in terms of retention and desorption of chloramphenicol. Competition and cross reactivity tests have proved that sol–gel MIP sorbent possesses significantly higher specific retention and enrichment capacity for chloramphenicol compared to its non-imprinted analogue. The maximum imprinting factor (IF) was found as 9.7, whereas the highest adsorption capacity of chloramphenicol by sol–gel MIP was 23 mg/g. The sol–gel MIP was found to be adequately selective towards chloramphenicol to provide the necessary minimum required performance limit (MRPL) of 0.3 μg/kg set forth by European Commission after analysis by LC-MS even without requiring time consuming solvent evaporation and sample reconstitution step, often considered as an integral part in solid phase extraction work

  13. Matrix molecularly imprinted mesoporous sol–gel sorbent for efficient solid-phase extraction of chloramphenicol from milk

    Energy Technology Data Exchange (ETDEWEB)

    Samanidou, Victoria, E-mail: samanidu@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki (Greece); Kehagia, Maria [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki (Greece); Kabir, Abuzar, E-mail: akabir@fiu.edu [International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States); Furton, Kenneth G. [International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States)

    2016-03-31

    Highly selective and efficient chloramphenicol imprinted sol–gel silica based inorganic polymeric sorbent (sol–gel MIP) was synthesized via matrix imprinting approach for the extraction of chloramphenicol in milk. Chloramphenicol was used as the template molecule, 3-aminopropyltriethoxysilane (3-APTES) and triethoxyphenylsilane (TEPS) as the functional precursors, tetramethyl orthosilicate (TMOS) as the cross-linker, isopropanol as the solvent/porogen, and HCl as the sol–gel catalyst. Non-imprinted sol–gel polymer (sol–gel NIP) was synthesized under identical conditions in absence of template molecules for comparison purpose. Both synthesized materials were characterized by Scanning Electron Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR) and nitrogen adsorption porosimetry, which unambiguously confirmed their significant structural and morphological differences. The synthesized MIP and NIP materials were evaluated as sorbents for molecularly imprinted solid phase extraction (MISPE) of chloramphenicol in milk. The effect of critical extraction parameters (flow rate, elution solvent, sample and eluent volume, selectivity coefficient, retention capacity) was studied in terms of retention and desorption of chloramphenicol. Competition and cross reactivity tests have proved that sol–gel MIP sorbent possesses significantly higher specific retention and enrichment capacity for chloramphenicol compared to its non-imprinted analogue. The maximum imprinting factor (IF) was found as 9.7, whereas the highest adsorption capacity of chloramphenicol by sol–gel MIP was 23 mg/g. The sol–gel MIP was found to be adequately selective towards chloramphenicol to provide the necessary minimum required performance limit (MRPL) of 0.3 μg/kg set forth by European Commission after analysis by LC-MS even without requiring time consuming solvent evaporation and sample reconstitution step, often considered as an integral part in solid phase extraction work

  14. Polyvinylidene Fluoride Micropore Membranes as Solid-Phase Extraction Disk for Preconcentration of Nanoparticulate Silver in Environmental Waters.

    Science.gov (United States)

    Zhou, Xiao-Xia; Lai, Yu-Jian; Liu, Rui; Li, Sha-Sha; Xu, Jing-Wen; Liu, Jing-Fu

    2017-12-05

    Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag + , aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 μg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.

  15. Determination of multi-class herbicides in soil by liquid-solid extraction coupled with headspace solid phase microextraction method

    Directory of Open Access Journals (Sweden)

    Đurović-Pejčev Rada

    2016-01-01

    Full Text Available A method is described for simultaneous determination of five herbicides (metribuzin, acetochlor, clomazone, oxyfluorfen and dimethenamid belonging to different pesticides groups in soil samples. Developed headspace solid phase microextraction method (HS-SPME in combination with liquid-solid sample preparation (LS was optimized and applied in the analysis of some agricultural samples. Optimization of microextraction conditions, such as temperature, extraction time and sodium chloride (NaCl content was perfor-med using 100 μm polydimethyl-siloxane (PDMS fiber. The extraction effi-ciencies of methanol, methanol:acetone=1:1 and methanol:acetone:hexane= =2:2:1 and the optimum number of extraction steps during the sample prepa-ration, were tested, as well. Gas chromatography-mass spectrometry (GC-MS was used for detection and quantification, obtaining relative standard deviation (RSD below 13%, and recovery values higher than 83% for multiple analyses of soil samples fortified at 30 μg kg-1 of each herbicide. Limits of detection (LOD were less than 1.2 μg kg-1 for all the studied herbicides. [Projekat Ministarstva nauke Republike Srbije, br. TR31043 i br. III43005

  16. Solid-phase extraction sorbent consisting of alkyltrimethylammonium surfactants immobilized onto strong cation-exchange polystyrene resin.

    Science.gov (United States)

    Reid, Kendra R; Kennedy, Lonnie J; Crick, Eric W; Conte, Eric D

    2002-10-25

    Presented is a solid-phase extraction sorbent material composed of cationic alkyltrimethylammonium surfactants attached to a strong cation-exchange resin via ion-exchange. The original hydrophilic cation-exchange resin is made hydrophobic by covering the surface with alkyl chains from the hydrophobic portion of the surfactant. The sorbent material now has a better ability to extract hydrophobic molecules from aqueous samples. The entire stationary phase (alkyltrimethylammonium surfactant) is removed along with the analyte during the elution step. The elution step requires a mild elution solvent consisting of 0.25 M Mg2+ in a 50% 2-propanol solution. The main advantage of using a removable stationary phase is that traditionally utilized toxic elution solvents such as methylene chloride, which are necessary to efficiently release strongly hydrophobic species from SPE stationary phases, may now be avoided. Also, the final extract is directly compatible with reversed-phase liquid chromatography. The performance of this procedure is presented using pyrene as a test molecule.

  17. Optimization and application of octadecyl-modified monolithic silica for solid-phase extraction of drugs in whole blood samples.

    Science.gov (United States)

    Namera, Akira; Saito, Takeshi; Ota, Shigenori; Miyazaki, Shota; Oikawa, Hiroshi; Murata, Kazuhiro; Nagao, Masataka

    2017-09-29

    Monolithic silica in MonoSpin for solid-phase extraction of drugs from whole blood samples was developed to facilitate high-throughput analysis. Monolithic silica of various pore sizes and octadecyl contents were synthesized, and their effects on recovery rates were evaluated. The silica monolith M18-200 (20μm through-pore size, 10.4nm mesopore size, and 17.3% carbon content) achieved the best recovery of the target analytes in whole blood samples. The extraction proceeded with centrifugal force at 1000rpm for 2min, and the eluate was directly injected into the liquid chromatography-mass spectrometry system without any tedious steps such as evaporation of extraction solvents. Under the optimized condition, low detection limits of 0.5-2.0ngmL -1 and calibration ranges up to 1000ngmL -1 were obtained. The recoveries of the target drugs in the whole blood were 76-108% with relative standard deviation of less than 14.3%. These results indicate that the developed method based on monolithic silica is convenient, highly efficient, and applicable for detecting drugs in whole blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Quantitation of promethazine and metabolites in urine samples using on-line solid-phase extraction and column-switching

    Science.gov (United States)

    Song, Q.; Putcha, L.; Harm, D. L. (Principal Investigator)

    2001-01-01

    A chromatographic method for the quantitation of promethazine (PMZ) and its three metabolites in urine employing on-line solid-phase extraction and column-switching has been developed. The column-switching system described here uses an extraction column for the purification of PMZ and its metabolites from a urine matrix. The extraneous matrix interference was removed by flushing the extraction column with a gradient elution. The analytes of interest were then eluted onto an analytical column for further chromatographic separation using a mobile phase of greater solvent strength. This method is specific and sensitive with a range of 3.75-1400 ng/ml for PMZ and 2.5-1400 ng/ml for the metabolites promethazine sulfoxide, monodesmethyl promethazine sulfoxide and monodesmethyl promethazine. The lower limits of quantitation (LLOQ) were 3.75 ng/ml with less than 6.2% C.V. for PMZ and 2.50 ng/ml with less than 11.5% C.V. for metabolites based on a signal-to-noise ratio of 10:1 or greater. The accuracy and precision were within +/- 11.8% in bias and not greater than 5.5% C.V. in intra- and inter-assay precision for PMZ and metabolites. Method robustness was investigated using a Plackett-Burman experimental design. The applicability of the analytical method for pharmacokinetic studies in humans is illustrated.

  19. A new solid-phase extraction disk based on a sheet of single-walled carbon nanotubes.

    Science.gov (United States)

    Niu, Hong Yun; Cai, Ya Qi; Shi, Ya Li; Wei, Fu Sheng; Liu, Jie Min; Jiang, Gui Bin

    2008-11-01

    A new kind of solid-phase extraction disk based on a sheet of single-walled carbon nanotubes (SWCNTs) is developed in this study. The properties of such disks are tested, and different disks showed satisfactory reproducibility. One liter of aqueous solution can pass through the disk within 10-100 min while still allowing good recoveries. Two disks (DD-disk) can be stacked to enrich phthalate esters, bisphenol A (BPA), 4-n-nonylphenol (4-NP), 4-tert-octylphenol (4-OP) and chlorophenols from various volumes of solution. The results show that SWCNT disks have high extraction ability for all analytes. The SWCNT disk can extract polar chlorophenols more efficiently than a C(18) disk from water solution. Unlike the activated carbon disk, analytes adsorbed by the new disks can be eluted completely with 8-15 mL of methanol or acetonitrile. Finally, the DD-disk system is used to pretreat 1000-mL real-world water samples spiked with BPA, 4-OP and 4-NP. Detection limits of 7, 25, and 38 ng L(-1) for BPA, 4-OP, and 4-NP, respectively, were achieved under optimized conditions. The advantages of this new disk include its strong adsorption ability, its high flow rate and its easy preparation.

  20. Matrix solid-phase dispersion extraction of organophosphorus pesticide using SiO2-poly(N-vinylimidazole)

    International Nuclear Information System (INIS)

    Gutiérrez-Solís, M C; Muñoz-Rodríguez, D; Carrera-Figueiras, C; Ávila-Ortega, A; Medina-Peralta, S

    2013-01-01

    A sorbent material based on silica particles modified with poly(N-vinylimidazole) (SiO 2 -PVI) has been evaluated for the treatment of samples by matrix solid-phase dispersion (MSPD). The extraction of four organophosphorus pesticides was done from a spiked tomato and the extracts were analyzed by gas chromatography coupled to mass spectrometry. Six elution solvents were evaluated and acetone was selected due to better recovery of the four pesticides and low background signal in the chromatograms. A factorial design 2 4 was used for selection of extraction conditions. The factors were contact time, acetone volume, treatment (with or without freeze-drying) and adsorbent (SiO 2 or SiO 2 -PVI). The best recoveries were obtained using 15 minutes of contact, 2 mL of solvent and sorbent without freeze-drying. The recoveries were between 60 and 83% for SiO 2 -PVI in spiked tomato with 0.2 and 0.8μg/g.

  1. Selective determination of caffeine in foods with 3D-graphene based ultrasound-assisted magnetic solid phase extraction.

    Science.gov (United States)

    Rahimi, Afshin; Zanjanchi, Mohammad Ali; Bakhtiari, Sadjad; Dehsaraei, Mohammad

    2018-10-01

    An efficient method was applied for extraction of caffeine in food samples. Three-dimensional graphene-Fe 3 O 4 (3D-G-Fe 3 O 4 ) nanoparticles was successfully synthesized and used as adsorbent in magnetic solid phase extraction (MSPE) step. The properties of synthesized adsorbent were characterized by fourier-transform infrared spectroscopy (FT-IR), scanning electron microscope (SEM), vibrating sample magnetometer (VSM), X-ray diffraction (XRD), Raman spectroscopy, Brunauer-Emmett-Teller (BET) and Barrett-Joyner-Halenda (BJH) methods. The influence of main parameters of extraction procedure such as ultrasound parameter, amount of nanoparticles, pH, salt concentration and desorption condition were investigated and optimized. Under the optimized experimental conditions, the figure of merit results showed excellent linear dynamic range (LDR) of 0.5-500 µg mL -1 , with determination coefficient (R 2 ) higher than 0.996 and limit of detection (LOD) of 0.1 µg mL -1 . Intra- and inter-day relative standard deviations (RSDs) were less than 5.9 and 7.1%, respectively. The method was successfully applied for determination of caffeine in different food samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Spherical agarose-coated magnetic nanoparticles functionalized with a new salen for magnetic solid-phase extraction of uranyl ion

    International Nuclear Information System (INIS)

    Serenjeh, Fariba Nazari; Hashemi, Payman; Ghiasvand, Ali Reza; Naeimi, Hossein; Zakerzadeh, Elham

    2016-01-01

    The authors describe a method for magnetic solid phase extraction of uranyl ions from water samples. It is based on the use of spherical agarose-coated magnetic nanoparticles along with magnetic field agitation. The salen type Schiff base N,N’-bis(4-hydroxysalicylidene)-1,2-phenylenediamine was synthesized from resorcinol in two steps and characterized by infrared and nucleic magnetic resonance spectroscopies. The particles were then activated by an epichlorohydrin method and functionalized with the Schiff base which acts as a selective ligand for the extraction of UO 2 (II). Following preconcentration and elution with HCl, the ions were quantified by spectrophotometry using Arsenazo III as the indicator. The effects of pH value, ionic strength and amount of the adsorbent on the extraction of UO 2 (II) were optimized by a multivariate central composite design method. Six replicate analyses under optimized conditions resulted in a recovery of 96.6 % with a relative standard deviation of 3.4 % for UO 2 (II). The detection limit of the method (at a signal-to-noise ratio of 3σ) is 10 μg L -1 . The method was successfully applied to the determination of UO 2 (II) in spiked water samples. (author)

  3. Determination of five pyrethroids in tea drinks by dispersive solid phase extraction with polyaniline-coated magnetic particles.

    Science.gov (United States)

    Wang, Yuanpeng; Sun, Ying; Gao, Yan; Xu, Bo; Wu, Qiong; Zhang, Hanqi; Song, Daqian

    2014-02-01

    The polyaniline-coated magnetic particles with bowl-shaped morphology (Fe3O4/C/PANI microbowls) were successfully prepared and characterized by scanning electron microscopy, transmission electron microscopy and vibrating sample magnetometry. The prepared microbowls were used as the magnetic adsorbent in dispersive solid phase extraction of five pyrethroids, including cyhalothrin, beta-cypermethrin, esfenvalerate, permethrin and bifenthrin in plain tea drinks. The effects of experiment factors, including amount of Fe3O4/C/PANI microbowls, pH value, ultrasound extraction time and desorption conditions, were investigated. The extraction recoveries obtained with 8 mg of magnetic microbowls were satisfactory, and the microbowls can be reused after easy washing. Thus, a simple, selective and effective method for the determination of the pyrethroids was established successfully. The results showed that the method had good linearity (r=0.9992-0.9998), and the limits of detections (LODs) were from 0.025 to 0.032 ng mL(-1). The intra-day and inter-day relative standard deviations (RSDs) were in the range of 2.4-6.1% and 3.5-8.8%, respectively. Recoveries obtained by analyzing the real tea drinks were in the range of 72.1-118.4%. © 2013 Published by Elsevier B.V.

  4. Alkaloid analysis by high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance

    DEFF Research Database (Denmark)

    Johansen, Kenneth; Ebild, S.J.; Christensen, S.B.

    2012-01-01

    %) as methanol-d containing 5% aqueous NHOH (30%) as eluents were successful, even though elution of alkaloids with pK of the corresponding acid above 10 proved difficult. Alkaloid extracts of Huperzia selago containing complex aliphatic alkaloids and Triclisia patens containing bisbenzylisoquinoline alkaloids...

  5. Separation of phenolic acids from sugarcane rind by online solid-phase extraction with high-speed counter-current chromatography.

    Science.gov (United States)

    Geng, Ping; Fang, Yingtong; Xie, Ronglong; Hu, Weilun; Xi, Xingjun; Chu, Qiao; Dong, Genlai; Shaheen, Nusrat; Wei, Yun

    2017-02-01

    Sugarcane rind contains some functional phenolic acids. The separation of these compounds from sugarcane rind is able to realize the integrated utilization of the crop and reduce environment pollution. In this paper, a novel protocol based on interfacing online solid-phase extraction with high-speed counter-current chromatography (HSCCC) was established, aiming at improving and simplifying the process of phenolic acids separation from sugarcane rind. The conditions of online solid-phase extraction with HSCCC involving solvent system, flow rate of mobile phase as well as saturated extent of absorption of solid-phase extraction were optimized to improve extraction efficiency and reduce separation time. The separation of phenolic acids was performed with a two-phase solvent system composed of butanol/acetic acid/water at a volume ratio of 4:1:5, and the developed online solid-phase extraction with HSCCC method was validated and successfully applied for sugarcane rind, and three phenolic acids including 6.73 mg of gallic acid, 10.85 mg of p-coumaric acid, and 2.78 mg of ferulic acid with purities of 60.2, 95.4, and 84%, respectively, were obtained from 150 mg sugarcane rind crude extracts. In addition, the three different elution methods of phenolic acids purification including HSCCC, elution-extrusion counter-current chromatography and back-extrusion counter-current chromatography were compared. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Quaternary ammonium-functionalized silica sorbents for the solid-phase extraction of aromatic amines under normal phase conditions.

    Science.gov (United States)

    Vidal, Lorena; Robin, Orlane; Parshintsev, Jevgeni; Mikkola, Jyri-Pekka; Riekkola, Marja-Liisa

    2013-04-12

    Quaternary ammonium-functionalized silica materials were synthesized and applied for solid-phase extraction (SPE) of aromatic amines, which are classified as priority pollutants by US Environmental Protection Agency. Hexamethylenetetramine used for silica surface modification for the first time was employed as SPE sorbent under normal phase conditions. Hexaminium-functionalized silica demonstrated excellent extraction efficiencies for o-toluidine, 4-ethylaniline and quinoline (recoveries 101-107%), while for N,N-dimethylaniline and N-isopropylaniline recoveries were from low to moderate (14-46%). In addition, the suitability of 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica as SPE sorbent was tested under normal phase conditions. The recoveries achieved for the five aromatic amines ranged from 89 to 99%. The stability of the sorbent was evaluated during and after 150 extractions. Coefficients of variation between 4.5 and 10.2% proved a high stability of the synthesized sorbent. Elution was carried out using acetonitrile in the case of hexaminium-functionalized silica and water for 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent. After the extraction the analytes were separated and detected by liquid chromatography ultraviolet detection (LC-UV). The retention mechanism of the materials was primarily based on polar hydrogen bonding and π-π interactions. Comparison made with activated silica proved the quaternary ammonium-functionalized materials to offer different selectivity and better extraction efficiencies for aromatic amines. Finally, 1-alkyl-3-(propyl-3-sulfonate) imidazolium-functionalized silica sorbent was successfully tested for the extraction of wastewater and soil samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Detection of urinary creatinine using gold nanoparticles after solid phase extraction

    Science.gov (United States)

    Sittiwong, Jarinya; Unob, Fuangfa

    2015-03-01

    Label-free gold nanoparticles (AuNPs) were utilized in the detection of creatinine in human urine after a sample preparation by extraction of creatinine on sulfonic acid functionalized silica gel. With the proposed sample preparation method, the interfering effects of the urine matrix on creatinine detection by AuNPs were eliminated. Parameters affecting creatinine extraction were investigated. The aggregation of AuNPs induced by creatinine resulted in a change in the surface plasmon resonance signal with a concomitant color change that could be observed by the naked eye and quantified spectrometrically. The effect of AuNP concentration and reaction time on AuNP aggregation was investigated. The method described herein provides a determination of creatinine in a range of 15-40 mg L-1 with a detection limit of 13.7 mg L-1 and it was successfully used in the detection of creatinine in human urine samples.

  9. Thin film-XRF determination of uranium following thin-film solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Jalal, E-mail: jalalhassan@ut.ac.ir [Department of Toxicology, Faculty of Veterinary Medicine, University of Tehran (Iran, Islamic Republic of); Hosseini, Seyed M.; Mozaffari, Shahla [Department of Chemistry, Payame Noor University, Tehran (Iran, Islamic Republic of); Jahanparast, Babak; Karbasi, Mohammad H. [Iranian Mineral Processing Research Center, Ministry of Industry and Mineral, Karaj (Iran, Islamic Republic of)

    2014-07-01

    A sensitive method based on the preconcentration of uranium on modified filter paper (thin film) has been developed to determinate this element in water and soil samples by wavelength dispersive X-ray fluorescence. Uranium (VI) extraction from nitric acid medium by trioctyl phosphine (TOPO) from 100 mL of sample was carried out. The effects of nitric acid concentration, TOPO concentration and sample breakthrough on uranium extraction were investigated in this study. The proposed method provided good linearity from 7 to 1000 μg and the limit of detection (LOD), based on a signal-to noise ratio (S/N) of 3, was 2.5 μg. (author)

  10. Preparation and evaluation of molecularly imprinted solid-phase micro-extraction fibers for selective extraction of phthalates in an aqueous sample

    International Nuclear Information System (INIS)

    He Juan; Lv Ruihe; Zhan Haijun; Wang Huizhi; Cheng Jie; Lu Kui; Wang Fengcheng

    2010-01-01

    A novel molecularly imprinted polymer (MIP) that was applied to a solid-phase micro-extraction (SPME) device, which could be coupled directly to gas chromatograph and mass spectrometer (GC/MS), was prepared using dibutyl phthalate (DBP) as the template molecule. The characteristics and application of this fiber were investigated. Electron microscope images indicated that the MIP-coated solid-phase micro-extraction (MI-SPME) fibers were homogeneous and porous. The extraction yield of DBP with the MI-SPME fibers was higher than that of the non-imprinted polymer (NIP)-coated SPME (NI-SPME) fibers. The MI-SPME fibers had a higher selectivity to other phthalates that had similar structures as DBP. A method was developed for the determination of phthalates using MI-SPME fibers coupled with GC/MS. The extraction conditions were optimized. Detection limits for the phthalate samples were within the range of 2.17-20.84 ng L -1 . The method was applied to five kinds of phthalates dissolved in spiked aqueous samples and resulted in recoveries of up to 94.54-105.34%, respectively. Thus, the MI-SPME fibers are suitable for the extraction of trace phthalates in complicated samples.

  11. Development of a comprehensive screening method for more than 300 organic chemicals in water samples using a combination of solid-phase extraction and liquid chromatography-time-of-flight-mass spectrometry.

    Science.gov (United States)

    Chau, Hong Thi Cam; Kadokami, Kiwao; Ifuku, Tomomi; Yoshida, Yusuke

    2017-12-01

    A comprehensive screening method for 311 organic compounds with a wide range of physicochemical properties (log Pow -2.2-8.53) in water samples was developed by combining solid-phase extraction with liquid chromatography-high-resolution time-of-flight mass spectrometry. Method optimization using 128 pesticides revealed that tandem extraction with styrene-divinylbenzene polymer and activated carbon solid-phase extraction cartridges at pH 7.0 was optimal. The developed screening method was able to extract 190 model compounds with average recovery of 80.8% and average relative standard deviations (RSD) of 13.5% from spiked reagent water at 0.20 μg L -1 , and 87.1% recovery and 10.8% RSD at 0.05 μg L -1 . Spike-recovery testing (0.20 μg L -1 ) using real sewage treatment plant effluents resulted in an average recovery and average RSD of 190 model compounds of 77.4 and 13.1%, respectively. The method was applied to the influent and effluent of five sewage treatment plants in Kitakyushu, Japan, with 29 out of 311 analytes being observed at least once. The results showed that this method can screen for a large number of chemicals with a wide range of physicochemical properties quickly and at low operational cost, something that is difficult to achieve using conventional analytical methods. This method will find utility in target screening of hazardous chemicals with a high risk in environmental waters, and for confirming the safety of water after environmental incidents.

  12. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets

    Energy Technology Data Exchange (ETDEWEB)

    Ghazaghi, Mehri [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Mousavi, Hassan Zavvar, E-mail: hzmousavi@semnan.ac.ir [Department of Chemistry, College of Science, Semnan University, P.O. Box: 35131-19111, Semnan (Iran, Islamic Republic of); Rashidi, Ali Morad [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Shirkhanloo, Hamid [Occupational and Environmental Health Research Center (OEHRC), Iranian Petroleum Industry Health Research Institute (IPIHRI), Tehran (Iran, Islamic Republic of); Rahighi, Reza [Nanotechnology Research Center, Research Institute of Petroleum Industry (RIPI), West Entrance Blvd., Olympic Village, P.O. Box: 14857-33111, Tehran (Iran, Islamic Republic of); Department of Research and Development, Sharif Ultrahigh Nanotechnologists (SUN) Company, P.O. Box: 13488-96394, Tehran (Iran, Islamic Republic of)

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL{sup −1}), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL{sup −1}). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L{sup −1} for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24–15.6, 0.015–0.95 and 0.039–2.33 µg L{sup −1} for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned

  13. Innovative separation and preconcentration technique of coagulating homogenous dispersive micro solid phase extraction exploiting graphene oxide nanosheets.

    Science.gov (United States)

    Ghazaghi, Mehri; Mousavi, Hassan Zavvar; Rashidi, Ali Morad; Shirkhanloo, Hamid; Rahighi, Reza

    2016-01-01

    A uniquely novel, fast, and facile technique is introduced for the first time in which a scant amount of graphene oxide (GO), without modification, has been utilized in dispersive mode of solid phase extraction (SPE) for an efficient yet simple separation. The proposed method of coagulating homogenous dispersive micro solid phase extraction (CHD-µSPE) is based on coagulation of homogeneous GO solution with the aid of polyetheneimine (PEI). CHD-µSPE use full adsorption capacity of GO because in this method was used GO solution obtained from synthesis process without drying step and stacking nanosheets. In optimized condition, 30 µL GO solution (7 mg mL(-1)), obtained in synthesis process, was injected into 1.5 mL the sample solution followed by immediate injection of 53 µL PEI solution (1 mg mL(-1)). After inserting PEI, GO sheets aggregate and can be readily separated by centrifugation. PEI not only cause aggregation of GO, but also form three-dimensional network of GO with easy handling in following separation steps. Lead, cadmium, and chromium were selected as model analytes and the effecting parameters including the amount of GO, concentration of PEI, sample pH, extraction time, and type of desorption solvent were investigated and optimized. The results indicate that the proposed CHD-µSPE method can be successfully applied GO in dispersive mode of SPE without effecting on good capability adsorption of GO. The novel method was applied in determination of lead, cadmium, and chromium in water, human saliva, and urine samples by electrothermal atomic absorption spectrometry. The detection limits are as low as 0.035, 0.005, and 0.012 µg L(-1) for Pb, Cd, and Cr respectively. The intra-day precisions (RSDs) were lower than 3.8%. CHD-µSPE method showed a good linear ranges of 0.24-15.6, 0.015-0.95 and 0.039-2.33 µg L(-1) for Pb, Cd and Cr respectively. Method performance was investigated by determination of mentioned metal ions in river water, human urine and

  14. Plutonium association with selected solid phases in soils of Rocky Flats, Colorado, using sequential extraction technique

    International Nuclear Information System (INIS)

    Litaor, M.I.; Ibrahim, S.A.

    1996-01-01

    Plutonium contamination in the soil environs of Rock Flats, CO, has been a potential health risk to the public since the late 1960s. Although the measurement of total activity of Pu-239 + 240 in the soil is important information in appraising this risk, total activity does not provide the information required to characterize the geochemical behavior that affects the transport of Pu from the soil and vadose zone to groundwater. A sequential extraction experiment was conducted to assess the geochemical association of Pu with selected mineralogical and chemical phases of the soil. In the surface horizons, Pu-239 + 240 was primarily associated with the organic C (45-65%), sesquioxides (20-40%), and the residual fraction (10-15%). A small portion of Pu-239+240 was associated with soluble (0.09-0.22%), exchangeable (0.04-0.08%), and carbonates (0.57-7.0%) phases. These results suggest that under the observed pH and oxic conditions, relatively little Pu-239 + 240 is available for geochemically induced transport processes. Uncommon hydrogeochemical conditions were observed during the spring of 1995, which may have facilitated a partial dissolution of sesquioxides followed by desorption of Pu resulting in increased Pu mobility. Systematic errors in the sequential extraction experiment due to postextraction readsorption were evaluated using Np-237 tracer as a surrogate to Pu-239. The results suggested that postextraction readsorption rates were insignificant during the first 30 min after extraction for most chemical and mineralogical phases under study. 50 refs., 2 figs., 5 tabs

  15. Head Space Solid Phase Micro-Extraction (HS - SPME of volatile organic compounds produced by Sporidiobolus salmonicolor (CBS 2636

    Directory of Open Access Journals (Sweden)

    Eunice Valduga

    2010-12-01

    Full Text Available The aim of the present study was the assessment of volatile organic compounds produced by Sporidiobolus salmonicolor (CBS 2636 using methyl and ethyl ricinoleate, ricinoleic acid and castor oil as precursors. The analysis of the volatile organic compounds was carried out using Head Space Solid Phase Micro-Extraction (HS - SPME. Factorial experimental design was used for investigating extraction conditions, verifying stirring rate (0-400 rpm, temperature (25-60 ºC, extraction time (10-30 minutes, and sample volume (2-3 mL. The identification of volatile organic compounds was carried out by Gas Chromatography with Mass Spectrum Detector (GC/MSD. The conditions that resulted in maximum extraction were: 60 ºC, 10 minutes extraction, no stirring, sample volume of 2.0 mL, and addition of saturated KCl (1:10 v/v. In the bio-production of volatile organic compounds the effect of stirring rate (120-200 rpm, temperature (23-33 ºC, pH (4.0-8.0, precursor concentration (0.02-0.1%, mannitol (0-6%, and asparagine concentration (0-0.2% was investigated. The bio-production at 28 ºC, 160 rpm, pH 6,0 and with the addition of 0.02% ricinoleic acid to the medium yielded the highest production of VOCs, identified as 1,4-butanediol, 1,2,2-trimethylciclopropilamine, beta-ionone; 2,3-butanodione, pentanal, tetradecane, 2-isononenal, 4-octen-3-one, propanoic acid, and octadecane.

  16. Simultaneous in situ derivatization and ultrasound-assisted dispersive magnetic solid phase extraction for thiamine determination by spectrofluorimetry.

    Science.gov (United States)

    Tarigh, Ghazale Daneshvar; Shemirani, Farzaneh

    2014-06-01

    A simple and rapid method for the simultaneous in situ derivatizaion, preconcentration and extraction of thiamine (vitamin B1) as a model analyte was developed by a novel quantitative method, namely ultrasound-assisted dispersive magnetic solid phase extraction spectrofluorimetry (USA-DMSPE-FL) from different real samples. This method consists of sample preparation, in situ derivatization, exhaustive extraction and clean up by a single process. High extraction efficiency and in situ derivatization in a short period of time is the main advantages of this procedure. For this purpose, the reusable magnetic multi-wall carbon nanotube (MMWCNT) nanocomposite was used as an adsorbent for preconcentration and determination of thiamine. Thiamine was, simultaneously, in situ derivatized as thiochrome by potassium hexacyanoferrate (III) and adsorbed on MMWCNT in an ultrasonic water bath. The MMWCNTs were then collected using an external magnetic field. Subsequently, the extracted thiochrome was washed from the surface of the adsorbent and determined by spectrofluorimetry. The developed method, which has been analytically characterized under its optimal operating conditions, allows the detection of the analyte in the samples with method detection limits of 0.37 µg L(-1). The repeatability of the method, expressed as the relative standard deviation (RSD, n=6), varies between 2.0% and 4.8% in different real samples, while the enhancement factor is 197. The proposed procedure has been applied for the determination of thiamine in biological (serum and urine), pharmaceutical (multivitamin tablet and B complex syrup) and foodstuff samples (cereal, wheat flour, banana and honey) with the good recoveries in the range from 90% to 105%. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Solid-phase extraction of the alcohol abuse biomarker phosphatidylethanol using newly synthesized polymeric sorbent materials containing quaternary heterocyclic groups.

    Science.gov (United States)

    Duarte, Mariana; Jagadeesan, Kishore Kumar; Billing, Johan; Yilmaz, Ecevit; Laurell, Thomas; Ekström, Simon

    2017-10-13

    Phosphatidylethanol (PEth) is an interesting biomarker finding increased use for detecting long term alcohol abuse with high specificity and sensitivity. Prior to detection, sample preparation is an unavoidable step in the work-flow of PEth analysis and new protocols may facilitate it. Solid-phase extraction (SPE) is a versatile sample preparation method widely spread in biomedical laboratories due to its simplicity of use and the possibility of automation. In this work, SPE was used for the first time to directly extract PEth from spiked human plasma and spiked human blood. A library of polymeric SPE materials with different surface functionalities was screened for PEth extraction in order to identify the surface characteristics that control PEth retention and recovery. The plasma samples were diluted 1:10 (v/v) in water and spiked at different concentrations ranging from 0.3 to 5μM. The library of SPE materials was then evaluated using the proposed SPE method and detection was done by LC-MS/MS. One SPE material efficiently retained and recovered PEth from spiked human plasma. With this insight, four new SPE materials were formulated and synthesized based on the surface characteristics of the best SPE material found in the first screening. These new materials were tested with spiked human blood, to better mimic a real clinical sample. All the newly synthetized materials outperformed the pre-existing commercially available materials. Recovery values for the new SPE materials were found between 29.5% and 48.6% for the extraction of PEth in spiked blood. A material based on quaternized 1-vinylimidazole with a poly(trimethylolpropane trimethacrylate) backbone was found suitable for PEth extraction in spiked blood showing the highest analyte recovery in this experiment, 48.6%±6.4%. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Unusual seeding mechanism for enhanced performance in solid-phase magnetic extraction of Rare Earth Elements

    Science.gov (United States)

    Polido Legaria, Elizabeth; Rocha, Joao; Tai, Cheuk-Wai; Kessler, Vadim G.; Seisenbaeva, Gulaim A.

    2017-03-01

    Due to the increasing demand of Rare Earth Elements (REE or RE), new and more efficient techniques for their extraction are necessary, suitable for both mining and recycling processes. Current techniques such as solvent extraction or solid adsorbents entail drawbacks such as using big volumes of harmful solvents or limited capacity. Hybrid nanoadsorbents based on SiO2 and highly stable γ-Fe2O3-SiO2 nanoparticles, proved recently to be very attractive for adsorption of REE, yet not being the absolute key to solve the problem. In the present work, we introduce a highly appealing new approach in which the nanoparticles, rather than behaving as adsorbent materials, perform as inducers of crystallization for the REE in the form of hydroxides, allowing their facile and practically total removal from solution. This induced crystallization is achieved by tuning the pH, offering an uptake efficiency more than 20 times higher than previously reported (up to 900 mg RE3+/g vs. 40 mg RE3+/g). The obtained phases were characterized by SEM-EDS, TEM, STEM and EFTEM and 13C and 29Si solid state NMR. Magnetic studies showed that the materials possessed enough magnetic properties to be easily removed by a magnet, opening ways for an efficient and industrially applicable separation technique.

  19. Solid phase extraction for determination of 90Sr in water sample

    International Nuclear Information System (INIS)

    Ometakova, J.

    2009-01-01

    We studied the use of an extraction chromatography for determination of 90 Sr in samples of contaminated water. The aim of the thesis was to compare selected products from the point of view of the strontium yields and time needed. Three commercial products: 3M Empore Strontium Rad Disk, AnaLig, Sr-Resin and two classical methods: liquid-liquid extraction with tributylphosphate and carbonate co-precipitation (to eliminate interferers) were used for separation of 90 Sr. The water sample was used in radiochemical analysis for determination volume activity of 90 Sr. A radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were counted over a two week period to monitor the ingrowth of 90 Y on TRI CARB LSC counter. Samples were measured using an HPGe detector to find out 85 Sr recoveries at 514 keV line and they were counted directly by Cherenkov counting after the growth of 90 Y using TriCarb LSC counter after a two- week period (author)

  20. Development and validation of a magnetic solid-phase extraction with high-performance liquid chromatography method for the simultaneous determination of amphetamine and methadone in urine.

    Science.gov (United States)

    Taghvimi, Arezou; Hamishehkar, Hamed; Ebrahimi, Mahmoud

    2016-06-01

    The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid-phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100-1500 ng/mL for amphetamine and 100-1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid-phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

    Science.gov (United States)

    Andersen, David W; Linnet, Kristian

    2014-01-01

    A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants.

    Science.gov (United States)

    Heub, Sarah; Tscharner, Noe; Kehl, Florian; Dittrich, Petra S; Follonier, Stéphane; Barbe, Laurent

    2016-01-01

    A new method for solid phase extraction (SPE) of environmental water samples is proposed. The developed prototype is cost-efficient and user friendly, and enables to perform rapid, automated and simple SPE. The pre-concentrated solution is compatible with analysis by immunoassay, with a low organic solvent content. A method is described for the extraction and pre-concentration of natural hormone 17β-estradiol in 100 ml water samples. Reverse phase SPE is performed with octadecyl-silica sorbent and elution is done with 200 µl of methanol 50% v/v. Eluent is diluted by adding di-water to lower the amount of methanol. After preparing manually the SPE column, the overall procedure is performed automatically within 1 hr. At the end of the process, estradiol concentration is measured by using a commercial enzyme-linked immune-sorbent assay (ELISA). 100-fold pre-concentration is achieved and the methanol content in only 10% v/v. Full recoveries of the molecule are achieved with 1 ng/L spiked de-ionized and synthetic sea water samples.

  3. Determination of catechins and catechin gallates in tissues by liquid chromatography with coulometric array detection and selective solid phase extraction.

    Science.gov (United States)

    Chu, Kai On; Wang, Chi Chiu; Chu, Ching Yan; Rogers, Michael Scott; Choy, Kwong Wai; Pang, Chi Pui

    2004-10-25

    Catechins levels in organ tissues, particularly liver, determined by published methods are unexpectedly low, probably due to the release of oxidative enzymes, metal ions and reactive metabolites from tissue cells during homogenization and to the pro-oxidant effects of ascorbic acid during sample processing in the presence of metal ions. We describe a new method for simultaneous analysis of eight catechins in tissue: (+)-catechin (C), (-)-epicatechin (EC), (-)-gallocatechin (GC), (-)-epigallocatechin (EGC), (-)-catechin gallate (CG), (-)-epicatechin gallate (ECG), (-)-gallocatechin gallate (GCG) and (-)-epigallocatechin gallate (EGCG) (Fig. 1). The new extraction procedure utilized a methanol/ethylacetate/dithionite (2:1:3) mixture during homogenization for simultaneous enzyme precipitation and antioxidant protection. Selective solid phase extraction was used to remove most interfering bio-matrices. Reversed phase HPLC with CoulArray detection was used to determine the eight catechins simultaneously within 25 min. Good linearity (>0.9922) was obtained in the range 20-4000 ng/g. The coefficients of variance (CV) were less than 5%. Absolute recovery ranged from 62 to 96%, accuracy 92.5 +/- 4.5 to 104.9 +/- 6%. The detection limit was 5 ng/g. This method is capable for determining catechins in rat tissues of liver, brain, spleen, and kidney. The method is robust, reproducible, with high recovery, and has been validated for both in vitro and in vivo sample analysis.

  4. Determination of Benzo(a)pyrene in Malaysian commercialized coffee powder using solid phase extraction and gas chromatography

    International Nuclear Information System (INIS)

    Noraini Kasim; Rozita Osman; Norashikin Saim; Licaberth Ismail

    2012-01-01

    Roasting is a critical process in coffee production as it enables the development of flavor and aroma. Benzo[a]pyrene (BaP) is a non desirable product of incomplete combustion at temperatures between 300 and 600 degree Celsius and may be produced during roasting step. In this study, selected samples of roasted coffee powder were analysed for BaP. Extraction of BaP was achieved using C 18 solid phase extraction (SPE) prior to analysis by gas chromatography. Calibration curve prepared with concentrations ranged between 3 - 50 ppm showed good linearity with r = 0.999. The limit of detection (LOD) was 0.25 ppm and the limit of quantification (LOQ) was 0.85 ppm. Recovery of BaP obtained from spiked sample (3 ppm) was 88.7 % with RSD (n=3) of 5.4 %. Benzo[a]pyrene was detected in all samples, at level ranging from 0.14 to 0.62 ppb. (author)

  5. Determination of phthalates released from paper packaging materials by solid-phase extraction-high-performance liquid chromatography.

    Science.gov (United States)

    Gao, Xin; Yang, Bofeng; Tang, Zhixu; Luo, Xin; Wang, Fengmei; Xu, Hui; Cai, Xue

    2014-01-01

    A solid phase extraction (SPE) high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of 10 phthalic acid esters (dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzylbutyl phthalate, diisobutyl phthalate, dicyclohexyl phthalate, diamyl phthalate, di-n-hexyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate) released from food paper packaging materials. The use of distilled water, 3% acetic acid (w/v), 10% ethanol (v/v) and 95% ethanol (v/v) instead of the different types of food simulated the migration of 10 phthalic acid esters from food paper packaging materials; the phthalic acid esters in four food simulants were enriched and purified by a C18 SPE column and nitrogen blowing, and quantified by HPLC with a diode array detector. The chromatographic conditions and extraction conditions were optimized and all 10 of the phthalate acid esters had a maximum absorbance at 224 nm. The method showed limitations of detection in the range of 6.0-23.8 ng/mL the correlation coefficients were greater than 0.9999 in all cases, recovery values ranged between 71.27 and 106.97% at spiking levels of 30, 60 and 90 ng/mL and relative standard deviation values ranged from 0.86 to 8.00%. The method was considered to be simple, fast and reliable for a study on the migration of these 10 phthalic acid esters from food paper packaging materials into food.

  6. Selective solid-phase extraction of Ni(II) by an ion-imprinted polymer from water samples

    International Nuclear Information System (INIS)

    Saraji, Mohammad; Yousefi, Hamideh

    2009-01-01

    A new ion-imprinted polymer (IIP) material was synthesized by copolymerization of 4-vinylpyridine as monomer, ethyleneglycoldimethacrylate as crosslinking agent and 2,2'-azobis-sobutyronitrile as initiator in the presence of Ni-dithizone complex. The IIP was used as sorbent in a solid-phase extraction column. The effects of sampling volume, elution conditions, sample pH and sample flow rate on the extraction of Ni ions form water samples were studied. The maximum adsorption capacity and the relative selectivity coefficients of imprinted polymer for Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were calculated. Compared with non-imprinted polymer particles, the IIP had higher selectivity for Ni(II). The relative selectivity factor (α r ) values of Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were 21.6, 54.3, and 22.7, respectively, which are greater than 1. The relative standard deviation of the five replicate determinations of Ni(II) was 3.4%. The detection limit for 150 mL of sample was 1.6 μg L -1 using flame atomic absorption spectrometry. The developed method was successfully applied to the determination of trace nickel in water samples with satisfactory results.

  7. Screening of a Combinatorial Library of Organic Polymers for the Solid-Phase Extraction of Patulin from Apple Juice

    Science.gov (United States)

    Giovannoli, Cristina; Spano, Giulia; Di Nardo, Fabio; Anfossi, Laura; Baggiani, Claudio

    2017-01-01

    Patulin is a water-soluble mycotoxin produced by several species of fungi. Governmental bodies have placed it under scrutiny for its potential negative health effects, and maximum residue limits are fixed in specific food matrices to protect consumers’ health. Confirmatory analysis of patulin in complex food matrices can be a difficult task, and sample clean-up treatments are frequently necessary before instrumental analyses. With the aim of simplifying the clean-up step, we prepared a 256-member combinatorial polymeric library based on 16 functional monomers, four cross-linkers and four different porogenic solvents. The library was screened for the binding towards patulin in different media (acetonitrile and citrate buffer at pH 3.2), with the goal of identifying polymer formulations with good binding properties towards the target compound. As a proof of concept, a methacrylic acid-co-pentaerithrytole tetraacrylate polymer prepared in chloroform was successfully used as a solid-phase extraction material for the clean-up and extraction of patulin from apple juice. Clean chromatographic patterns and acceptable recoveries were obtained for juice spiked with patulin at concentration levels of 25 (64 ± 12%), 50 (83 ± 5.6%) and 100 μg L−1 (76 ± 4.5%). The within-day and between-day reproducibility evaluated at a concentration level of 25 μg L−1 were 5.6 and 7.6%, respectively. PMID:28531103

  8. Selective solid-phase extraction using oxidized activated carbon modified with triethylenetetramine for preconcentration of metal ions

    Science.gov (United States)

    Zhang, Li; Chang, Xijun; Li, Zhenhua; He, Qun

    2010-02-01

    A new selective solid-phase extractant using activated carbon as matrix which was purified, oxidized and modified by triethylenetetramine (AC-TETA) was prepared and characterized by FT-IR spectroscopy. At pH 4, quantitative extraction of trace Cr(III), Fe(III) and Pb(II) was obtained and determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Complete elution of the adsorbed metal ions from the sorbent surface was carried out using 0.5 mol L -1 HCl. The maximum static adsorption capacity of sorbent for Cr(III), Fe(III) and Pb(II) was 34.6, 36.5 and 51.9 mg g -1, respectively. The time of quantitative adsorption was less than 2 min. The detection limits of the method was found to be 0.71, 0.35 and 0.45 ng mL -1 for Cr(III), Fe(III) and Pb(II), and the relative standard deviation (RSD) was 3.7%, 2.2% and 2.5%, respectively. Moreover, the method was free from interference with common coexiting ions. The method was also successfully applied to the preconcentration of trace Cr(III), Fe(III) and Pb(II) in synthetic samples and a real sample with satisfactory results.

  9. Combining Pickering Emulsion Polymerization with Molecular Imprinting to Prepare Polymer Microspheres for Selective Solid-Phase Extraction of Malachite Green

    Directory of Open Access Journals (Sweden)

    Weixin Liang

    2017-08-01

    Full Text Available Malachite green (MG is currently posing a carcinogenic threat to the safety of human lives; therefore, it is highly desirable to develop an effective method for fast trace detection of MG. Herein, for the first time, this paper presents a systematic study on polymer microspheres, being prepared by combined Pickering emulsion polymerization and molecular imprinting, to detect and purify MG. The microspheres, molecularly imprinted with MG, show enhanced adsorption selectivity to MG, despite a somewhat lowered adsorption capacity, as compared to the counterpart without molecular imprinting. Structural features and adsorption performance of these microspheres are elucidated by different characterizations and kinetic and thermodynamic analyses. The surface of the molecularly imprinted polymer microspheres (M-PMs exhibits regular pores of uniform pore size distribution, endowing M-PMs with impressive adsorption selectivity to MG. In contrast, the microspheres without molecular imprinting show a larger average particle diameter and an uneven porous surface (with roughness and a large pore size, causing a lower adsorption selectivity to MG despite a higher adsorption capacity. Various adsorption conditions are investigated, such as pH and initial concentration of the solution with MG, for optimizing the adsorption performance of M-PMs in selectively tackling MG. The adsorption kinetics and thermodynamics are deeply discussed and analyzed, so as to provide a full picture of the adsorption behaviors of the polymer microspheres with and without the molecular imprinting. Significantly, M-PMs show promising solid-phase extraction column applications for recovering MG in a continuous extraction manner.

  10. Graphene oxide bound silica for solid-phase extraction of 14 polycyclic aromatic hydrocarbons in mainstream cigarette smoke.

    Science.gov (United States)

    Shi, Rui; Yan, Lihong; Xu, Tongguang; Liu, Dongye; Zhu, Yongfa; Zhou, Jun

    2015-01-02

    Polycyclic aromatic hydrocarbons (PAHs) were considered as a source of carcinogenicity in mainstream cigarette smoke (MSS). Accurate quantification of these components was necessary for assessing public health risk. In our study, a solid-phase extraction (SPE) method using graphene oxide (GO) bound silica as adsorbent for purification of 14 PAHs in MSS was developed. During SPE process, large matrices interferences of MSS were adsorbed on SPE column. The result of FTIR spectra demonstrated that these matrices interferences were adsorbed on GO mainly through OH and CO groups. The concentrations of PAHs in MSS extract were determined by gas chromatography-mass spectrometry (GC-MS). The limit of detection (LOD) and limit of quantification (LOQ) of the developed method for 14 PAHs ranged from 0.05 to 0.36 ng/cig and 0.17 to 1.19 ng/cig, respectively. The accuracy of the measurement of 14 PAHs was from 73 to 116%. The relative standard deviations of intra- and inter-day analysis were less than 7.8% and 13.9%, respectively. Moreover, the developed method was successfully applied for analysis of real cigarette containing 1R5F reference cigarette and 12 top-selling commercial cigarettes in China. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Simultaneous Determination of TetracyclinesResidues in Bovine Milk Samples by Solid Phase Extraction and HPLC-FL Method

    Directory of Open Access Journals (Sweden)

    Mehra Mesgari Abbasi

    2011-06-01

    Full Text Available Introduction:Tetracyclines (TCs are widely used in animal husbandry and their residues in milk may resultinharmful effects on human. The aim of this study was to investigate the presence of TCs residues in various bovine milk samples from local markets of Ardabil, Iran. Methods:One hundred and fourteen pasteurized, sterilized and raw milk samples were collected from markets of Ardabil. Tetracycline, Oxytetracycline and Chlortetracycline (TCs residues extraction carried out by Solid Phase Extraction method. Determination of TCs residues were performed by high performance liquid chromatography (HPLC method using Fluorescence detector.Results: The mean of total TCs residues in all samples (114 samples was 97.6 ±16.9ng/g and that of pasteurized, sterilized and raw milk samples were 87.1 ± 17.7, 112.0 ± 57.3 and 154.0 ± 66.3ng/g respectively. Twenty five point four percent of the all samples, and24.4%, 30% and 28.6% of the pasteurized, sterilized and raw milk samples, respectively had higher TCs residues than the recommended maximum levels (100ng/g. Conclusion:This study indicates the presence of tetracycline residues more than allowed amount. Regulatory authorities should ensure proper withdrawal period before milking the animals and definite supervisions are necessary on application of these drugs.

  12. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    Science.gov (United States)

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Rapid method for determination of glyphosate in groundwater using high performance liquid chromatography and solid-phase extraction after derivatization

    Directory of Open Access Journals (Sweden)

    Valdir Eduardo Olivo

    2015-04-01

    Full Text Available The intensive use of pesticides in agriculture has prompted researchers to develop new methods for identifying these pollutants in water. This study sought to validate a high performance liquid chromatography (HPLC method to determine the concentration of the pesticide glyphosate in groundwater samples by using solid-phase extraction (SPE filters after derivatization with chloroformate 9-fluorenylmethoxycarbonyl (FMOC-Cl. For the HPLC method, we evaluated the following main validation parameters: linearity, specificity, precision, accuracy, robustness, and limits of detection and quantification. After validation of the method, we determined the concentration of glyphosate in samples from thirteen deep, tubular wells distributed in urban and rural areas in Chapecó, SC, Brazil. The solvent used in the extraction of excess FMOC-Cl was dichloromethane and subsequently filtration was performed on C18 SPE, and injected into the chromatograph column in amino polymer with fluorescence detection. The analytical curve made in ultrapure water was linear, with a correlation coefficient of 0.99. The limits of detection and quantification were 0.24 and 0.07 µg L-1, respectively. Recovery tests in natural waters ranged from 90.37 to 101.70%. Glyphosate was detected in 5 of the thirteen wells evaluated. The highest concentration of glyphosate (6.80 µg L-1 was detected in a countryside well, near the municipal water supply. Despite the low levels of glyphosate detected in our study, any amount present in groundwater samples is worrisome, as these molecules have low ground mobility.

  14. Determination of amphetamine-type stimulants (ATSs) and synthetic cathinones in urine using solid phase micro-extraction fibre tips and gas chromatography-mass spectrometry

    OpenAIRE

    Alsenedi, Khalid A.; Morrison, Calum

    2018-01-01

    In recent years, an increasing number of stimulant drugs and new psychoactive substances (NPSs) have caused concern in scientific communities and therefore innovative methods to extract compounds from complex biological samples are required. This work is aimed at developing and validating a clean, convenient and straightforward extraction procedure with microliter amounts of organic solvent using Solid Phase Micro-Extraction tips (SPME tips) and analysis using Gas Chromatography-Mass Spectrom...

  15. Determination of the Antibiotic Oxytetracycline in Commercial Milk by Solid-Phase Extraction: A High-Performance Liquid Chromatography (HPLC) Experiment for Quantitative Instrumental Analysis

    Science.gov (United States)

    Mei-Ratliff, Yuan

    2012-01-01

    Trace levels of oxytetracylcine spiked into commercial milk samples are extracted, cleaned up, and preconcentrated using a C[subscript 18] solid-phase extraction column. The extract is then analyzed by a high-performance liquid chromatography (HPLC) instrument equipped with a UV detector and a C[subscript 18] column (150 mm x 4.6 mm x 3.5 [mu]m).…

  16. A rapid and validated HPLC method to quantify sphingosine 1-phosphate in human plasma using solid-phase extraction followed by derivatization with fluorescence detection

    NARCIS (Netherlands)

    Butter, Jan J.; Koopmans, Richard P.; Michel, Martin C.

    2005-01-01

    We describe the development and validation of analytical methodology for the determination of sphingosine 1-phosphate (S1P) in plasma. It uses solid-phase extraction (SPE) followed by an automated reversed-phase gradient HPLC column-switching system with a pre-column derivatization with

  17. Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction-gas chromatography-mass selective detection.

    NARCIS (Netherlands)

    Louter, A.J.H.; van Beekvelt, C.A.; Cid Montanes, P.; Slobodník, J.; Vreuls, J.J.; Brinkman, U.A.T.

    1996-01-01

    The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small

  18. Determination of inorganic arsenic in algae using bromine halogenation and on-line nonpolar solid phase extraction followed by hydride generation atomic flourescence spectrometry

    Science.gov (United States)

    Accurate, stable and fast analysis of toxic inorganic arsenic (iAs) in complicated and arsenosugar-rich algae matrix is always a challenge. Herein, a novel analytical method for iAs in algae was reported, using bromine halogenation and on-line nonpolar solid phase extraction (SPE) followed by hydrid...

  19. QUANTITATIVE DETERMINATION OF CHIRAL DICHLORPROP AND MECOPROP ENANTIOMERS IN DRINKING AND SURFACE WATERS BY SOLID-PHASE EXTRACTION AND CAPILLARY ELECTROPHORESIS

    Czech Academy of Sciences Publication Activity Database

    Tříska, Jan; Vrchotová, Naděžda

    2002-01-01

    Roč. 11, č. 7 (2002), s. 332-336 ISSN 1018-4619 Institutional research plan: CEZ:AV0Z6087904 Keywords : capillary electrophoresis * solid-phase extraction * chiral herbicides Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 0.309, year: 2002

  20. Trace-level determination of polar flavour compounds in butter by solid-phase extraction and gas chromatography-mass spectrometry.

    NARCIS (Netherlands)

    Adahchour, M.; Vreuls, J.J.; van der Heijden, A.; Brinkman, U.A.T.

    1999-01-01

    Volatile compounds are responsible for the aromas of butter. A simple technique for the determination of these components is described which is based on solid-phase extraction (SPE) after melting of the butter and separation of the aqueous phase from the fat. Volatile flavours present in the water

  1. Determination of phenolic derivatives of antipyrine in plasma with solid-phase extraction and high-performance liquid chromatography-atmospheric-pressure chemical ionization mass spectrometry

    NARCIS (Netherlands)

    Coolen, S.A.J.; Ligor, T.; Lieshout, van H.P.M.; Huf, F.A.

    1999-01-01

    This manuscript describes a method to determine antipyrine and its phenolic derivatives in plasma by reversed-phase high-performance liquid chromatography–mass spectrometry (RP-HPLC–MS). The sample pretreatment consisted of a C18 solid-phase extraction (SPE), to remove the salts and proteins. The

  2. Data correlation in on-line solid-phase extraction-gas chromatography-atomic emission/mass spectrometric detection of unknown microcontaminants

    NARCIS (Netherlands)

    Hankemeier, Th.; Rozenbrand, J.; Abhadur, M.; Vreuls, J.J.; Brinkman, U.A.Th.

    1998-01-01

    A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC

  3. Utilizing thin-film solid-phase extraction to assess the effect of organic carbon amendments on the bioavailability of DDT and dieldrin to earthworms

    Science.gov (United States)

    Improved approaches are needed to rapidly and accurately assess the bioavailability of persistent, hydrophobic organic compounds in soils at contaminated sites. The performance of a thin-film solid-phase extraction (TF-SPE) assay using vials coated with ethylene vinyl acetate polymer was compared to...

  4. Solid phase extraction for multiresidue analysis of anabolic steroids and related substances from calf urine using C18 and alumina columns

    NARCIS (Netherlands)

    Koole, A; Franke, JP; de Zeeuw, RA

    1999-01-01

    A solid phase extraction method for anabolic steroids and related substances in calf urine is reported, that is suitable as a screening method for illegal growth promoters. Two types of sorbent were used: a reversed phase C18 material and a polar alumina material. After overnight enzymatic

  5. Isocratic Solid Phase Extraction-Liquid Chromatography (SPE-LC) Interfaced to High-Performance Tandem Mass Spectrometry for Rapid Protein Identification

    DEFF Research Database (Denmark)

    Hørning, Ole B; Kjeldsen, Frank; Theodorsen, Søren

    2008-01-01

    the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation ( approximately 8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer...

  6. The use of solid sorbents for direct accumulation of organic compounds from water matrices : a review of solid-phase extraction techniques

    NARCIS (Netherlands)

    Liska, I.; Krupcik, J.; Leclercq, P.A.

    1989-01-01

    The main principles of solid-phase extraction techniques are reviewed in this paper. Various solid sorbents can be used as a suitable trap for direct accumulation of organic compounds from aqueous solutions. The trapped analytes can be desorbed by elution with suitably chosen liquid phases. These

  7. An LC-MS Assay with Isocratic Separation and On-Line Solid Phase Extraction to Improve the Routine Therapeutic Drug Monitoring of Busulfan in Plasma

    Directory of Open Access Journals (Sweden)

    Ialongo Cristiano

    2017-04-01

    Full Text Available Background: Busulfan (Bu requires therapeutic drug monitoring (TDM in subjects undergoing a conditioning regimen for hematopoietic stem cell transplantation (HSCT. To speed up the procedure and increase reproducibility, we improved our routine LC-MS/MS assay using the on-line solid-phase extraction (SPE of samples.

  8. LC-UV-solid-phase extraction-NMR-MS combined with a cryogenic flow probe and its application to the identification of compounds present in Greek oregano

    NARCIS (Netherlands)

    Exarchou, V.; Godejohann, M.; Beek, van T.A.; Gerothanassis, I.P.; Vervoort, J.J.M.

    2003-01-01

    Structure elucidation of natural products usually relies on a combination of NMR spectroscopy with mass spectrometry whereby NMR trails MS in terms of the minimum sample amount required. In the present study, the usefulness of on-line solid-phase extraction (SPE) in LC-NMR for peak storage after the

  9. Separation and determination of citrinin in corn using HPLC fluorescence detection assisted by molecularly imprinted solid phase extraction clean-up

    Science.gov (United States)

    A liquid chromatography based method to detect citrinin in corn was developed using molecularly imprinted solid phase extraction (MISPE) sample clean-up. Molecularly imprinted polymers were synthesized using 1,4-dihydroxy-2-naphthoic acid as the template and an amine functional monomer. Density func...

  10. DEVELOPMENT OF METHOD 535 FOR THE DETERMINATION OF CHLOROACETANILIDE AND OTHER ACETAMIDE HERBICIDE DEGRADATES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY

    Science.gov (United States)

    EPA Method 535 has been developed in order to provide a method for the analysis of "Alachlor ESA and other acetanilide degradation products" which are listed on U.S. EPA's 1998 Drinking Water Contaminant Candidate List. Method 535 uses solid phase extraction with a nonporous gr...

  11. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    Science.gov (United States)

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  12. SEMIAUTOMATED SOLID-PHASE EXTRACTION PROCEDURE FOR DRUG SCREENING IN BIOLOGICAL-FLUIDS USING THE ASPEC SYSTEM IN COMBINATION WITH CLEAN SCREEN DAU COLUMNS

    NARCIS (Netherlands)

    CHEN, XH; FRANKE, JP; ENSING, K; WIJSBEEK, J; DEZEEUW, RA

    1993-01-01

    The use of a semi-automated solid-phase extraction system (ASPEC) for the screening of drugs in plasma and urine on a single mixed-mode column (Clean Screen DAU) is described. The processes of column preconditioning, sample application, column wash, pH adjustment and elution of the drugs were

  13. Magnetic graphene oxide modified with choline chloride-based deep eutectic solvent for the solid-phase extraction of protein

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yanhua; Wang, Yuzhi, E-mail: wyzss@hnu.edu.cn; Pan, Qi; Wang, Ying; Ding, Xueqin; Xu, Kaijia; Li, Na; Wen, Qian

    2015-06-02

    Highlights: • A strategy for extraction of protein based on DES-coated magnetic graphene oxide. • The deep eutectic solvents were based on choline chloride. • Bovine serum albumin was used as the analyte. • The material prepared works for the acidic but not the basic or the neutral proteins. - Abstract: Four kinds of green deep eutectic solvents (DESs) based on choline chloride (ChCl) have been synthesized and coated on the surface of magnetic graphene oxide (Fe{sub 3}O{sub 4}@GO) to form Fe{sub 3}O{sub 4}@GO-DES for the magnetic solid-phase extraction of protein. X-ray diffraction (XRD), vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FESEM) and thermal gravimetric analysis (TGA) were employed to characterize Fe{sub 3}O{sub 4}@GO-DES, and the results indicated the successful preparation of Fe{sub 3}O{sub 4}@GO-DES. The UV–vis spectrophotometer was used to measure the concentration of protein after extraction. Single factor experiments proved that the extraction amount was influenced by the types of DESs, solution temperature, solution ionic strength, extraction time, protein concentration and the amount of Fe{sub 3}O{sub 4}@GO-DES. Comparison of Fe{sub 3}O{sub 4}@GO and Fe{sub 3}O{sub 4}@GO-DES was carried out by extracting bovine serum albumin, ovalbumin, bovine hemoglobin and lysozyme. The experimental results showed that the proposed Fe{sub 3}O{sub 4}@GO-DES performs better than Fe{sub 3}O{sub 4}@GO in the extraction of acidic protein. Desorption of protein was carried out by eluting the solid extractant with 0.005 mol L{sup −1} Na{sub 2}HPO{sub 4} contained 1 mol L{sup −1} NaCl. The obtained elution efficiency was about 90.9%. Attributed to the convenient magnetic separation, the solid extractant could be easily recycled.

  14. State-of-the-art in solid-phase extraction of biofluids (M10)

    International Nuclear Information System (INIS)

    Boos, K.-S.; Fleischer, C.T.

    2002-01-01

    Full text: A major drawback of many SPE protocols in bioanalytical LC is a rather unselective and/or time consuming clean-up procedure. In order to optimize SPE based sample processing with regard to selectivity and speed we investigated tailor-made SPE adorbents, distinct SPE column hardware as well as a novel software (ChromSword ADS, Merck KGaA) for LC(MS)-integrated SPE using column-switching. Restricted Access Materials (RAM) are one family of such special SPE column packing. RAMs are characterized in that they have a defined size-selective exclusion barrier and a non-adsorptive outer particle surface towards macromolecular matrix components (e.g. proteins, nucleic acids, polysaccharides). Low-molecular compounds (e.g. drugs) have free access to the binding centers and thus can be extracted and enriched prior to their analytical separation and MS detection. A RAM-SPE column (e.g. LiChrospher ADS, Merck KGaA, Germany) allows the direct, multiple injection and fractionation of crude, complex samples such as hemolyzed blood, plasma, serum, milk, saliva, urine, fermentation broth and cell-culture or tissue homogenate supernatant. In order to improve the selectivity, we extended this on-line sample clean-up protocol by coupling a reversed-phase modified RAM-SPE column with a second short column packed with a Molecularly Imprinted Polymeric (MIP) adsorbent. MIP-SPE adsorbents can be compared with immunoaffinity adsorbents. Besides selective/specific molecular recognition properties, these artificial antibodies exhibit a high stability with respect to pressure, pH, temperature as well as organic solvents. These innovative adsorbents are also attractive because of the ease, low-cost and high reproducibility of preparation. Using MIPS in combination with RAMs we developed a generic SPE platform and protocol, respectively, for highly selective clean-up of complex (bio)fluids. Finally, we succeeded in speeding up the RAM fractionation step (e.g. extraction of 50 pl of

  15. Characteristic of New Solid-Phase Extraction Sorbent: Activated Carbon Prepared from Rice Husks under Base Treated Condition

    Directory of Open Access Journals (Sweden)

    Afrida Kurnia Putri

    2012-10-01

    Full Text Available A characterization of activated carbon (ACs prepared from rice husks (RHs under base treated condition as a new sorbent for solid-phase extraction (SPE to extract 4-nonylphenol isomers (4-NPs in water samples has been done. The ACs prepared from RHs usually exhibits low specific surface area due to its high ash content, but in case of its application for SPE, there are other factors need to be considered, such as the existence of functional groups inside the sorbent, that can enhance interaction of non-polar sorbent with analyte in the water matrices. In this case, silanol groups from ash content may affect the extraction efficiency for 4-NPs. The ACs made from RHs were chemically impregnated with ZnCl2 and carbonized at 800oC. To investigate the role of silica, three types of ACs were prepared, i.e., untreated ACs (AC–Si, contain silica, base treated ACs (AC–B–Si, remain some silica inside, and ACs made by base treated RHs (AC–B, no silica, the surface area obtained from these treatments were 1352 m2/g, 1666 m2/g, and 1712m2/g respectively.  ACs made by base treatment has the highest surface area (related to BET, which indicat that silica removal process promotes the formation of open pore system on ACs and enhances the surface area of ACs. However, extraction efficiency measured by GC-MS in SPE process showed the reversal trends (i.e., AC–Si= 32.08%, AC–B–Si= 82.63%, AC–B=51.78%, among them the AC–B–Si sorbent reveal the best performance in SPE process. It is indicated that although silica usually exhibits low specific surface area, but control presence of silica as a polar functional group has a positive influence in the interaction between non-polar sorbent and 4-NPs.

  16. Development of a solid-phase extraction method with simple MEKC-UV analysis for simultaneous detection of indole metabolites in human urine after administration of indole dietary supplement.

    Science.gov (United States)

    Phonchai, Apichai; Wilairat, Prapin; Chantiwas, Rattikan

    2017-11-01

    This work presents the development of a solid phase extraction method with simple MEKC-UV analysis for the simultaneous determination of indole-3-carbinol (I3C) and its metabolites (3, 3'-diindolylmethane (DIM), indole-3-carboxaldehyde (I3CAL), indole-3-acetonitrile (I3A)) in human urine after oral administration of an indole dietary supplement. Solid phase extraction (SPE) method was applied for the first time for simultaneous analysis of these indole metabolites. The MEKC separation method was developed in a previous work. Three commercial SPE cartridges, each with different sorbent materials, were investigated: Sep-Pak ® C18, Oasis ® HLB and Oasis ® WCX. The Sep-Pak ® C18 material provided the highest extraction recovery of 88-113% (n = 9), for the four target indole metabolites (I3C, DIM, I3CAL and I3A). The optimal washing and elution solutions were 40% methanol/water (v/v) and 100% methanol, respectively, and optimal elution volume was 2.0mL. The specificity of the proposed SPE method was evaluated with negative control urine samples (n = 10) from healthy volunteers who had not taken the dietary supplement or vegetables known to contain indole compounds. Linear calibration curves were in the range of 0.2-25μgmL -1 (r 2 > 0.998) using diphenylamine (DPA) as the internal standard. Intra-day and inter-day precisions were 3.5-12.3%RSD and 2.7-14.1%RSD, respectively. Limits of detection and quantification were 0.05-0.10μgmL -1 and 0.10-0.50μgmL -1 , respectively. The four target indole compounds were separated within only 5min by MEKC-UV analysis. Urine from 5 subjects who had taken a dietary supplement containing I3C and DIM were found to contain only the DIM metabolite at concentrations ranging from 0.10 to 0.35µgmL -1 . Accuracy of the proposed method based on the percentage recovery of spiked urine samples were 70-108%, 82-116%, 82-132% and 80-100% for I3C, I3CAL, I3A and DIM, respectively. The Sep-Pak ® C18 cartridge was highly effective in

  17. Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Burkhardt, M.R.; Gates, Paul M.; Werner, S.L.; Battaglin, W.A.

    2000-01-01

    Sulfonylurea (SU), imidazolinone (IMI), and sulfonamide (SA) herbicides are new classes of low-application-rate herbicides increasingly used by farmers. Some of these herbicides affect both weed and crop species at low dosages and must be carefully used. Less is known about the effect of these compounds on non-crop plant species, but a concentration of 100 ng/l in water has been proposed as the threshold for possible plant toxicity for most of these herbicides. Hence, analytical methods must be capable of detecting SUs, IMIs, and SAs at concentrations less than 100 ng/l in ambient water samples. The authors developed a two-cartridge, solid-phase extraction method for isolating 12 SU, 3 IMI, and 1 SA herbicides by using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS) to identify and quantify these herbicides to 10 ng/l. This method was used to analyze 196 surface- and ground-water samples collected from May to August 1998 throughout the Midwestern United States, and more than 100 quality-assurance and quality-control samples. During the 16 weeks of the study, the HPLC/ESI-MS maintained excellent calibration linearity across the calibration range from 5 to 500 ng/l, with correlation coefficients of 0.9975 or greater. Continuing calibration verification standards at 100-ng/l concentration were analyzed throughout the study, and the average measured concentrations for individual herbicides ranged from 93 to 100 ng/l. Recovery of herbicides from 27 reagent-water samples spiked at 50 and 100 ng/l ranged from 39 to 92%, and averaged 73%. The standard deviation of recoveries ranged from 14 to 26%, and averaged 20%. This variability reflects multiple instruments, operators, and the use of automated and manual sample preparation. Spiked environmental water samples had similar recoveries, although for some herbicides, the sample matrix enhanced recoveries by as much as 200% greater than the spiked concentration. This matrix

  18. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    International Nuclear Information System (INIS)

    Ameli, Akram; Alizadeh, Naader

    2011-01-01

    Highlights: ► Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. ► This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. ► Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 × 10 −8 to 5 × 10 −4 and 1.2 × 10 −6 to 5 × 10 −4 mol mL −1 and the detection limit was 4 × 10 −8 mol L −1 . The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  19. A novel magnetic poly(aniline-naphthylamine)-based nanocomposite for micro solid phase extraction of rhodamine B

    International Nuclear Information System (INIS)

    Bagheri, Habib; Daliri, Rasoul; Roostaie, Ali

    2013-01-01

    Graphical abstract: -- Highlights: •A Fe 3 O 4 –aniline-naphthylamine nanocomposite was prepared via a simple route. •The magnetic nanocomposite was applied for isolation of RhB from water. •The nanocomposite applicability was compared with other pristine polymers. •The method was applied for the determination of RhB in different samples. -- Abstract: A novel Fe 3 O 4 –poly(aniline-naphthylamine)-based nanocomposite was synthesized by chemical oxidative polymerization process as a magnetic sorbent for micro solid phase extraction. The scanning electron microscopy images of the synthesized nanocomposite revealed that the copolymer posses a porous structure with diameters less than 50 nm. The extraction efficiency of this sorbent was examined by isolation of rhodamine B, a mutagenic and carcinogenic dye, from aquatic media in dispersion mode. Among different synthesized polymers, Fe 3 O 4 /poly(aniline-naphthylamine) nanocomposite showed a prominent efficiency. Parameters including the desorption solvent, amount of sorbent, desorption time, sample pH, ionic strength, extraction time and stirring rate were optimized. Under the optimum condition, a linear spiked calibration curve in the range of 0.35–5.00 μg L −1 with R 2 = 0.9991 was obtained. The limits of detection (3S b ) and limits of quantification (10S b ) of the method were 0.10 μg L −1 and 0.35 μg L −1 (n = 3), respectively. The relative standard deviation for water sample with 0.5 μg L −1 of RhB was 4.2% (n = 5) and the absolute recovery was 92%. The method was applied for the determination of rhodamine B in dishwashing foam, dishwashing liquid, shampoo, pencil, matches tips and eye shadows samples and the relative recovery percentage were in the range of 94–99%

  20. Vortex-homogenized matrix solid-phase dispersion for the extraction of short chain chlorinated paraffins from indoor dust samples.

    Science.gov (United States)

    Chen, Yu-Hsuan; Chang, Chia-Yu; Ding, Wang-Hsien

    2016-11-11

    A simple and effective method for determining short chain chlorinated paraffins (SCCPs) in indoor dust is presented. The method employed a modified vortex-homogenized matrix solid-phase dispersion (VH-MSPD) prior to its detection by gas chromatography - electron-capture negative-ion mass spectrometry (GC-ECNI-MS) operating in the selected-ion-monitoring (SIM) mode. Under the best extraction conditions, 0.1-g of dust sample was dispersed with 0.1-g of silica gel by using vortex (2min) instead of using a mortar and pestle (3min). After that step, the blend was transferred to a glass column containing 3-g acidic silica gel, 2-g basic silica gel, and 2-g of deactivated silica gel, used as clean-up co-sorbents. Then, target analytes were eluted with 5mL of n-hexane/dichloromethane (2:1, v/v) mixture. The extract was evaporated to dryness under a gentle stream of nitrogen. The residue was then re-dissolved in n-hexane (10μL), and subjected to GC-ECNI-MS analysis. The limits of quantitation (LOQs) ranged from 0.06 to 0.25μg/g for each SCCP congener. Precision was less than 7% for both intra- and inter-day analysis. Trueness was above 89%, which was calculated by mean extraction recovery. The VH-MSPD combined with GC-ECNI-MS was successfully applied to quantitatively detect SCCPs from various indoor dust samples, and the concentrations ranged from 1.2 to 31.2μg/g. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. A simple method for the small scale synthesis and solid-phase extraction purification of steroid sulfates.

    Science.gov (United States)

    Waller, Christopher C; McLeod, Malcolm D

    2014-12-01

    Steroid sulfates are a major class of steroid metabolite that are of growing importance in fields such as anti-doping analysis, the detection of residues in agricultural produce or medicine. Despite this, many steroid sulfate reference materials may have limited or no availability hampering the development of analytical methods. We report simple protocols for the rapid synthesis and purification of steroid sulfates that are suitable for adoption by analytical laboratories. Central to this approach is the use of solid-phase extraction (SPE) for purification, a technique routinely used for sample preparation in analytical laboratories around the world. The sulfate conjugates of sixteen steroid compounds encompassing a wide range of steroid substitution patterns and configurations are prepared, including the previously unreported sulfate conjugates of the designer steroids furazadrol (17β-hydroxyandrostan[2,3-d]isoxazole), isofurazadrol (17β-hydroxyandrostan[3,2-c]isoxazole) and trenazone (17β-hydroxyestra-4,9-dien-3-one). Structural characterization data, together with NMR and mass spectra are reported for all steroid sulfates, often for the first time. The scope of this approach for small scale synthesis is highlighted by the sulfation of 1μg of testosterone (17β-hydroxyandrost-4-en-3-one) as monitored by liquid chromatography-mass spectrometry (LCMS). Copyright © 2014 Elsevier Inc. All rights reserved.

  2. [A novel ship-borne positive pressure solid phase extraction device to enrich organo chlorinated and pyrethroid pesticides in seawater].

    Science.gov (United States)

    Ye, Jianglei

    2017-09-08

    A novel solid phase extraction (SPE) device driven by positive pressure was developed instead of negative pressure from a vacuum pump, in order to enrich organo chlorinated and pyrethroid pesticides in seawater. The water sampling bottles and the pipelines which touch water samples were made of plastic material without chlorine. In order to ensure the sealing and firmness, the whole device were tightened with nut and bolt. The inner pressure (0.1-0.3 MPa) in the water sampling bottle was provided by the small air pump (powered by 12 V cell) controlled by a microprogrammed control unit (MCU) and pressure sensor to keep the water flow rate (4.0-6.0 mL/min). The pre-conditioned SPE column can be used for the enrichment of pesticides within four weeks, and the loaded SPE column can be eluted for detection within six weeks with recoveries greater than 80%. The linearity of the method was good with the correlation coefficient more than 0.9. The limits of quantification (LOQs) were 0.8-6 ng/L. The recoveries of the pesticides at three spiked levels (3 parallel samples) were 86.1%-95.5% with the relative standard deviations less than 10%. The benzene hexachlorides (BHCs) and dichloro-diphenyl-trichloroethanes (DDTs) were detected in seawater samples. The device has good application in enriching organo chlorinated and pyrethroid pesticides in seawater.

  3. Solid-Phase Extraction Coupled to a Paper-Based Technique for Trace Copper Detection in Drinking Water.

    Science.gov (United States)

    Quinn, Casey W; Cate, David M; Miller-Lionberg, Daniel D; Reilly, Thomas; Volckens, John; Henry, Charles S

    2018-03-20

    Metal contamination of natural and drinking water systems poses hazards to public and environmental health. Quantifying metal concentrations in water typically requires sample collection in the field followed by expensive laboratory analysis that can take days to weeks to obtain results. The objective of this work was to develop a low-cost, field-deployable method to quantify trace levels of copper in drinking water by coupling solid-phase extraction/preconcentration with a microfluidic paper-based analytical device. This method has the advantages of being hand-powered (instrument-free) and using a simple "read by eye" quantification motif (based on color distance). Tap water samples collected across Fort Collins, CO, were tested with this method and validated against ICP-MS. We demonstrate the ability to quantify the copper content of tap water within 30% of a reference technique at levels ranging from 20 to 500 000 ppb. The application of this technology, which should be sufficient as a rapid screening tool, can lead to faster, more cost-effective detection of soluble metals in water systems.

  4. Multifunctional silver nanoparticle-doped silica for solid-phase extraction and surface-enhanced Raman scattering detection

    Science.gov (United States)

    Markina, Natalia E.; Markin, Alexey V.; Zakharevich, Andrey M.; Gorin, Dmitry A.; Rusanova, Tatiana Yu.; Goryacheva, Irina Yu.

    2016-12-01

    Multifunctional silica gel with embedded silver nanoparticles (SiO2-AgNP) is proposed for application as sorbent for solid-phase extraction (SPE) and simultaneously as substrate for surface-enhanced Raman spectroscopy (SERS) due to their high sorption properties and ability to enhance Raman signal (SERS-active sorbents). SiO2-AgNP was synthesized via alkaline hydrolysis of tetraethyl orthosilicate with simultaneous reduction of silver ions to silver nanoparticles (AgNP) within the SiO2 bulk. Synthesis of AgNP directly to the SiO2 matrix enables to exclude any additional stabilizers for the nanoparticles that educes signal-to-noise ratio during SERS measurement. Apart from Raman spectroscopy, obtained sorbents were also characterized by scanning electron microscopy and UV-visible diffuse reflectance spectroscopy. The influence of AgNO3 concentration used during the SiO2-AgNP synthesis on its gelling time, color, diffuse reflectance spectra, and enhancement of Raman signal was investigated. A Raman enhancement factor of SiO2-AgNP with optimal composition was around 105. Finally, the sorbents were applied for SPE and subsequent SERS detection of model compounds (rhodamine 6G and folic acid). It was found that SPE enables to decrease detectable concentrations by two orders. Therefore, SPE combined with SERS has high potential for further analytical investigations.

  5. Quantitative determination of 1,4-dioxane and tetrahydrofuran in groundwater by solid phase extraction GC/MS/MS.

    Science.gov (United States)

    Isaacson, Carl; Mohr, Thomas K G; Field, Jennifer A

    2006-12-01

    Groundwater contamination by cyclic ethers, 1,4-dioxane (dioxane), a probable human carcinogen, and tetrahydrofuran (THF), a co-contaminant at many chlorinated solvent release sites, are a growing concern. Cyclic ethers are readily transported in groundwater, yet little is known about their fate in environmental systems. High water solubility coupled with low Henry's law constants and octanol-water partition coefficients make their removal from groundwater problematic for both remedial and analytical purposes. A solid-phase extraction (SPE) method based on activated carbon disks was developed for the quantitative determination of dioxane and THF. The method requires 80 mL samples and a total of 1.2 mL of solvent (acetone). The number of steps is minimized due to the "in-vial" elution of the disks. Average recoveries for dioxane and THF were 98% and 95%, respectively, with precision, as indicated by the relative standard deviation of <2% to 6%. The method quantitation limits are 0.31 microg/L for dioxane and 3.1 microg/L for THF. The method was demonstrated by analyzing groundwater samples for dioxane and THF collected during a single sampling campaign at a TCA-impacted site. Dioxane concentrations and areal extent of dioxane in groundwater were greater than those of either TCA or THF.

  6. Zincon-modified activated carbon for solid-phase extraction and preconcentration of trace lead and chromium from environmental samples.

    Science.gov (United States)

    Li, Zhenhua; Chang, Xijun; Hu, Zheng; Huang, Xinping; Zou, Xiaojun; Wu, Qiong; Nie, Rong

    2009-07-15

    A new method that utilizes zincon-modified activated carbon (AC-ZCN) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III) and Pb(II) prior to the measurement by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 4, the maximum adsorption capacity of Cr(III) and Pb(II) onto the AC-ZCN were 17.9 and 26.7 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 1 mL of 0.1 mol L(-1) HCl. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3 sigma) of this method for Cr(III) and Pb(II) were 0.91 and 0.65 ng mL(-1), respectively. The relative standard deviation under optimum condition is less than 3.5% (n=8). The method has been applied for the determination of Cr(III) and Pb(II) in biological materials and water samples with satisfactory results.

  7. Magnetic Solid Phase Extraction and Removal of Five Cationic Dyes from Aqueous Solution Using Magnetite Nanoparticle Loaded Platanusorientalis Waste Leaves

    Directory of Open Access Journals (Sweden)

    Elaheh Madrakian

    2016-12-01

    Full Text Available This paper reports on synthesis of a magnetic adsorbent for wastewater treatment purposes. In this regard, platanus orientalis waste leaves were chosen as a cheap material for preparing the magnetic adsorbent by loading magnetite nanoparticles on it. The synthesized adsorbent was characterized using scanning electron microscope and X-ray diffractometer. Then, it was used for magnetic solid phase extraction and removal of five cationic dyes including methyl violet (MV, methylene blue (MB, malachite green (MG, crystal violet (CV, and neutral red (NR from aqueous solution as a model application. Different important factors affecting the adsorption process were optimized, and the results showed that under the optimized conditions (pH 10 for CV, MV, MB, and MG; pH 6 for NR; adsorbent dosage, 20 mg; agitation time, 25 min efficient removal of the investigated dyes (adsorption capacities between of 89-133 mg g-1 is achievable using the synthesized adsorbent. Furthermore, the reusability experiments showed that the adsorbent could be reused at least ten cycles without any significant loss in its sorption behavior.

  8. Miniaturized solid-phase extraction of macrolide antibiotics in honey and bovine milk using mesoporous MCM-41 silica as sorbent.

    Science.gov (United States)

    Du, Li-Jing; Yi, Ling; Ye, Li-Hong; Chen, Yu-Bo; Cao, Jun; Peng, Li-Qing; Shi, Yu-Ting; Wang, Qiu-Yan; Hu, Yu-Han

    2018-02-16

    A simple and effective method of miniaturized solid-phase extraction (mini-SPE) was developed for the simultaneous purification and enrichment of macrolide antibiotics (MACs) (i.e. azithromycin, clarithromycin, erythromycin, lincomycin and roxithromycin) from honey and skim milk. Mesoporous MCM-41 silica was synthesized and used as sorbent in mini-SPE. Several key parameters affecting the performance of mini-SPE procedure were thoroughly investigated, including sorbent materials, amount of sorbent and elution solvents. Under the optimized condition, satisfactory linearity (r 2  > 0.99), acceptable precision (RSDs, 0.3-7.1%), high sensitivity (limit of detection in the range of 0.01-0.76 μg/kg), and good recoveries (83.21-105.34%) were obtained. With distinct advantages of simplicity, reliability and minimal sample requirement, the proposed mini-SPE procedure coupled with ultrahigh performance liquid chromatography and quadrupole time-of-flight tandem mass spectrometry could become an alternative tool to analyze the residues of MACs in complex food matrixes. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Multifunctional silver nanoparticle-doped silica for solid-phase extraction and surface-enhanced Raman scattering detection

    Energy Technology Data Exchange (ETDEWEB)

    Markina, Natalia E.; Markin, Alexey V., E-mail: av-markin@mail.ru; Zakharevich, Andrey M.; Gorin, Dmitry A.; Rusanova, Tatiana Yu.; Goryacheva, Irina Yu. [Saratov State University (Russian Federation)

    2016-12-15

    Multifunctional silica gel with embedded silver nanoparticles (SiO{sub 2}–AgNP) is proposed for application as sorbent for solid-phase extraction (SPE) and simultaneously as substrate for surface-enhanced Raman spectroscopy (SERS) due to their high sorption properties and ability to enhance Raman signal (SERS-active sorbents). SiO{sub 2}–AgNP was synthesized via alkaline hydrolysis of tetraethyl orthosilicate with simultaneous reduction of silver ions to silver nanoparticles (AgNP) within the SiO{sub 2} bulk. Synthesis of AgNP directly to the SiO{sub 2} matrix enables to exclude any additional stabilizers for the nanoparticles that educes signal-to-noise ratio during SERS measurement. Apart from Raman spectroscopy, obtained sorbents were also characterized by scanning electron microscopy and UV-visible diffuse reflectance spectroscopy. The influence of AgNO{sub 3} concentration used during the SiO{sub 2}–AgNP synthesis on its gelling time, color, diffuse reflectance spectra, and enhancement of Raman signal was investigated. A Raman enhancement factor of SiO{sub 2}–AgNP with optimal composition was around 10{sup 5}. Finally, the sorbents were applied for SPE and subsequent SERS detection of model compounds (rhodamine 6G and folic acid). It was found that SPE enables to decrease detectable concentrations by two orders. Therefore, SPE combined with SERS has high potential for further analytical investigations.

  10. Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Tetracycline Residues in Milk

    Directory of Open Access Journals (Sweden)

    Gabriela Islas

    2018-01-01

    Full Text Available Solid-phase extraction in combination with large-volume sample stacking-capillary electrophoresis (SPE-LVSS-CE was applied to measure chlortetracycline, doxycycline, oxytetracycline, and tetracycline in milk samples. Under optimal conditions, the proposed method had a linear range of 29 to 200 µg·L−1, with limits of detection ranging from 18.6 to 23.8 µg·L−1 with inter- and intraday repeatabilities < 10% (as a relative standard deviation in all cases. The enrichment factors obtained were from 50.33 to 70.85 for all the TCs compared with a conventional capillary zone electrophoresis (CZE. This method is adequate to analyze tetracyclines below the most restrictive established maximum residue limits. The proposed method was employed in the analysis of 15 milk samples from different brands. Two of the tested samples were positive for the presence of oxytetracycline with concentrations of 95 and 126 µg·L−1. SPE-LVSS-CE is a robust, easy, and efficient strategy for online preconcentration of tetracycline residues in complex matrices.

  11. Assessment of solid phase microfiber extraction fibers for the monitoring of volatile organoarsinicals emitted from a plant-soil system.

    Science.gov (United States)

    Ruppert, L; Lin, Z-Q; Dixon, R P; Johnson, K A

    2013-11-15

    Phytoremediation, the use of plants and microbes to clean up inorganic and organic pollutants, has shown great promise as an inexpensive and feasible form of remediation. More recently, studies have shown that some plants have an amazing capacity to volatilize contaminants and can be an effective remediation strategy if the chemicals released are non-toxic. Arsenic contamination and remediation has drawn great attention in the scientific community. However, its toxicity also varies depending on its form. We evaluated, optimized, and then utilized a solid phase microfiber extraction (SPME) head space sampling technique to characterize the organoarsinical emissions from rabbitfoot grass (Polypogon monspeliensis) in arsenic treated soils to determine if the potentially more toxic organic forms of arsenic (AsH3, AsH2CH3, AsH(CH3)2, and As(CH3)3) were being emitted from the plant-soil system. The SPME fiber that proved best fitted for this application was the DVB/CAR/PDMS fiber with a 45 min sampling period. We did detect and confirm the emissions of dimethylchloroarsine (AsCl(CH3)2) and pentamethylarsine (As(CH3)5). However, it was determined that the more toxic organic forms of arsenic were not released during phytovolatilization. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Determination of Bile Acids in Piglet Bile by Solid Phase Extraction and Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    Science.gov (United States)

    Mi, Si; Lim, David W; Turner, Justine M; Wales, Paul W; Curtis, Jonathan M

    2016-03-01

    An LC/MS/MS-based method was developed for the determination of individual bile acids (BA) and their conjugates in porcine bile samples. The C18-based solid-phase extraction (SPE) procedure was optimized so that all 19 target BA and their glycine and taurine conjugates were collected with high recoveries for standards (89.1-100.2%). Following this, all 19 compounds were separated and quantified in a single 12 min chromatographic run. The method was validated in terms of linearity, sensitivity, accuracy, precision, and recovery. An LOD in the low ppb range with measured precisions in the range of 0.5-9.3% was achieved. The recoveries for all of the 19 analytes in bile samples were all >80%. The validated method was successfully applied to the profiling of BA and their conjugates in the bile from piglets treated with exogenous glucagon-like peptide-2 (GLP-2) in a preclinical model of neonatal parenteral nutrition-associated liver disease (PNALD). The method developed is rapid and could be easily implemented for routine analysis of BA and their conjugates in other biofluids or tissues.

  13. Determination of diethylstilbestrol in seawater by molecularly imprinted solid-phase extraction coupled with high-performance liquid chromatography.

    Science.gov (United States)

    He, Xiuping; Mei, Xiaoqi; Wang, Jiangtao; Lian, Ziru; Tan, Liju; Wu, Wei

    2016-01-15

    An effective and highly selective molecularly imprinted material was prepared by suspension polymerization for the isolation and pre-concentration of synthetic estrogen diethylstilbestrol (DES) in seawater. The obtained MIPMs were proved to have more uniform size and porous structure, with maximum adsorption capacity of 8.43 mg g(-1) almost two times more than NIPMs (4.43 mg g(-1)). The MIPMs showed no significant deterioration of the adsorption capacity after five rounds of regeneration. An off-line molecularly imprinted solid phase extraction (MISPE) method followed by HPLC-DAD was proposed for the detection of DES in seawater, and recoveries were satisfactorily higher than 77%. Four seawater samples in aquaculture area were analyzed and 0.61 ng mL(-1) DES was detected in one sample. The result demonstrated that this method can be used for the rapid separation and clean up of trace residual of DES in seawater. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of pesticides in water by graphitized carbon-based solid-phase extraction and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Anderson, Bruce D.; Werner, Stephen L.; Soliven, Paul P.; Coffey, Laura J.; Burkhardt, Mark R.

    2001-01-01

    In 1996, the U.S. Geological Survey National Water Quality Laboratory (NWQL) developed and implemented a graphitized carbon-based solid-phase extraction and high-performance liquid chromatographic analytical method to determine polar pesticide concentrations in surface- and ground-water samples. Subsequently, the NWQL developed a complementary analysis that uses high-performance liquid chromatography/mass spectrometry to detect, identify, and quantify polar pesticides and pesticide metabolites in filtered water at concentrations as low as 10 nanograms per liter. This new method was designed to improve sensitivity and selectivity over the prior method, and to reduce known interferences from natural organic matter.In this new method, pesticides are extracted from filtered water samples by useing a 0.5-gram graphitized carbon-based solid-phase extraction cartridge, eluted from the cartridge, and concentrations determined by using high-performance liquid chromatography with electrospray ionization-mass spectrometry. The upper concentration limit is 1.000 microgram per liter (μg/L) for most compounds. Single-operator method detection limits in organic-free water samples fortified with pesticides at a concentration of 0.025 μg/L ranged from 0.0019 to 0.022 μg/L for all compounds in the method. The grand mean (mean of mean recoveries for individual compounds) recoveries in organic-free water samples ranged from 72 to 89 percent, fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Grand mean recoveries in ground- and surface-water samples ranged from 46 to 119 percent, also fortified with pesticides at three concentrations between 0.025 and 0.5 μg/L. Long-term recoveries from reagent water spikes were used to demonstrate that 38 of 65 compounds can be reported without qualification of the quantitative result across the analytical range of the method. The remaining 27 are reported with qualified estimates of concentration because of greater

  15. An absorbing microwave micro-solid-phase extraction device used in non-polar solvent microwave-assisted extraction for the determination of organophosphorus pesticides.

    Science.gov (United States)

    Wang, Ziming; Zhao, Xin; Xu, Xu; Wu, Lijie; Su, Rui; Zhao, Yajing; Jiang, Chengfei; Zhang, Hanqi; Ma, Qiang; Lu, Chunmei; Dong, Deming

    2013-01-14

    A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60°C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC-MS without any clean-up process. The recoveries were in the range of 93.5-104.6%, and the relative standard deviations were lower than 8.7%. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Disposable cartridge extraction of retinol and alpha-tocopherol from fatty samples.

    Science.gov (United States)

    Bourgeois, C F; Ciba, N

    1988-01-01

    A new approach is proposed for liquid/solid extraction of retinol and alpha-tocopherol from samples, using a disposable kieselguhr cartridge. The substitution of the mixture methanol-ethanol-n-butanol (4 + 3 + 1) for methanol in the alkaline hydrolysis solution makes it now possible to process fatty samples. Methanol is necessary to solubilize the antioxidant ascorbic acid, and a linear chain alcohol such as n-butanol is necessary to reduce the size of soap micelles so that they can penetrate into the kieselguhr pores. In comparisons of the proposed method with conventional methods on mineral premixes and fatty feedstuffs, recovery and accuracy are at least as good by the proposed method. Advantages are increased rate of determinations and the ability to hydrolyze and extract retinol and alpha-tocopherol together from the same sample.

  17. Application of an Activated Carbon-Based Support for Magnetic Solid Phase Extraction Followed by Spectrophotometric Determination of Tartrazine in Commercial Beverages

    OpenAIRE

    Rodr?guez, Jos? A.; Escamilla-Lara, Karen A.; Guevara-Lara, Alfredo; Miranda, Jose M.; P?ez-Hern?ndez, Ma. Elena

    2015-01-01

    A method is presented for magnetic solid phase extraction of tartrazine from nonalcoholic beverages. The method involves the extraction and clean-up by activated carbon covered with magnetite dispersed in the sample, followed by the magnetic isolation and desorption of the analyte by basified methanol. The tartrazine eluted from the magnetic support was determined by spectrophotometry. Under optimal conditions, the linear range of the calibration curve ranges from 3 to 30?mg?L?1, with a limit...

  18. Utilization of modified corn silk as a biosorbent for solid-phase extraction of Cr(III) and chromium speciation.

    Science.gov (United States)

    Yu, Hongmei; Pang, Jing; Wu, Mei; Wu, Qiaoli; Huo, Cuixiu

    2014-01-01

    The ues of corn silk modified with diluted nitric acid (HNO3-MCS) as a novel biosorbent has been established for solid-phase extraction of Cr(III) and chromium speciation in water samples. The functional groups of the HNO3-MCS surface are favorable for the adsorption of Cr(III). Effective extraction conditions were optimized in both batch and column methods. At pH 3.0 - 6.0, a discrimination of Cr(III) and Cr(VI) is achieved on the HNO3-MCS surface. Cr(III) ions are retained onto the HNO3-MCS surface, however, the adsorption of Cr(VI) is negligible under the same conditions. The adsorption isotherm of HNO3-MCS for Cr(III) has been demonstrated in accordance with a linear form of the Langmuir equation, and the maximum adsorption capacity is 35.21 mg g(-1). The well fitted linear regression of the pseudo-second order model showed the indication of a chemisorption mechanism for the entire concentration range. Thermodynamic studies have shown that the adsorption process is spontaneous and endothermic. The adsorbed Cr(III) was quantitatively eluted by a nitric acid solution with detection by flame atomic absorption spectrometry (FAAS). With a sample volume of 30 mL, a detection limit (3σ) of 0.85 μg L(-1) and a precision of 2.0% RSD at the 40 μg L(-1) level were achieved. The concentration of Cr(III) could be accurately quantified within a linear range of 3 - 200 μg L(-1). After Cr(VI) has been reduced to Cr(III) with hydroxylamine hydrochloride, the total amount of chromium was obtained, and the content of Cr(VI) was given by subtraction. The procedure was validated by analyzing chromium in a certified reference material (GBW (E) 080039). It was also successfully applied for the speciation of chromium in wastewater samples.

  19. Valuation of solid phase extraction disks in the determination of pesticide residues in surface and groundwater in Panama

    International Nuclear Information System (INIS)

    Jimenez, V.; Ramos de Jimenez, J.; Rojas, B.

    1999-01-01

    In Panama large quantities of pesticides are used in agriculture and livestock farming and there is increasing concern about their impact on public health and the environment. Chiriqui is the Province that registers the largest number of producers whose activities have impact on the environment, especially on surface and groundwater. Systematic monitoring programmes are non-existent due, in part, to the high cost of laboratory determination of environmental residues of pesticides. Within the framework of the FAO/IAEA/SIDA Coordinated Research Programme, efforts were focused on evaluating and optimising the use of solid phase extraction C 18 membrane disks in the analysis of surface and groundwater samples to determine pesticide residues. Factors studied were the effect of pre-washing and conditioning of the disks, flow rates, concentration level and matrix effects of field samples. Four pesticides, carbofuran, chlorothalonil, ametryn and chlorpyrifos were selected for these tests because preliminary analysis showed their presence in surface and groundwater. The technique significantly reduces the amount of organic solvents used as compared with the liquid-liquid extraction method. Quantifiable detection limits (Q L ) for the method were found to be 0.003 μg/L carbofuran, 0.016 μg/L chlorothalonil, 0.007 μg/L ametryn and 0.003 μg/L chlorpyrifos, when using standard spiked solutions. Recovery (%) was high when standard mixtures were used for the test runs but low when real surface water samples were tested, especially for chlorothalonil which was not recovered at all. (author)

  20. Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

    Science.gov (United States)

    Arena, Matteo P.; Porter, Marc D.; Fritz, James S.

    2002-01-01

    A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene-divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of approximately 60 s with a RSD of approximately 6%.

  1. Solid-phase extraction with slurry injection of the resin into ETAAS for trace determination of thallium in natural water

    International Nuclear Information System (INIS)

    Isoshi, Nukatsuka; Hiroyuki, Seitoh; Kunio, Ohzeki

    2004-01-01

    Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A TI-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25 mm ) by filtration under suction using a glass funnel with an effective filtration area of 0.64 cm 2 . As a result, a circular thin layer of the resin phase with a diameter of 9 mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mm hole to put it into a sample cup containing 100 μL of 10 mM HNO 3 containing 0.5 mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15 min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0-4 ng of TI in 100 mL of a sample solution. The detection limit obtained by 3 σ method was 0.19 ng. The proposed method was applied to the determination of TI in natural water samples. The results showed the concentration of TI in seawater was 12.1 ± 1.8 pg mL -1 for the calibration graph method and 12.6 ± 1.4 pg mL -1 for the standard addition method. A snowmelt sample contained 20.7 ± 1.0 pg mL -1 of TI. (author)

  2. Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Orzechowska, G. E.; Kidd, R. D.; Foing, B. H.; Kanik, I.; Stoker, C.; Ehrenfreund, P.

    2011-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

  3. Magnetic nanoparticles grafted with β-cyclodextrin for solid-phase extraction of 5-hydroxy-3-indole acetic acid

    International Nuclear Information System (INIS)

    Ahmed, Gaber Hashem Gaber; Laíño, Rosana Badía; Calzón, Josefa Angela García; García, Marta Elena Díaz

    2014-01-01

    We describe the synthesis of β-cyclodextrin modified magnetic nanoparticles (CD-mNPs) as a material for solid-phase extraction of the cancer biomarker 5-hydroxy-indole-3-acetic acid (5-HIAA) from urine. The CD-mNPs were characterized by TEM, FTIR, and XRD, and the kinetics and adsorption isotherms were studied. The strong interaction between the CD-mNPs and 5-HIAA is the main driving force for recognition and extraction, while the magnetic core of the NPs allows their separation from the sample matrix. Recovery of 5-HIAA from the adsorbent using an adequate solvent regenerated the adsorbent for further use. 5-HIAA was then quantified by fluorometry of its complex with β-CD. The method works in the 1 × 10 −7 to 1 × 10 −5 mol L −1 (R 2 0.9982–0.9996) concentration range, and the limits of detection (3σ) and quantification (10 σ) of the method are 1.2 × 10 −8 mol L −1 and 4.01 × 10 −8 mol L −1 5-HIAA, respectively. The recovery of 5-HIAA from urine samples spiked with 5-HIAA in three concentrations (1.4 × 10 −6 , 4.50 × 10 −6 and 1.0 × 10 −5 mol L −1 ) are within 63 ± 3 %. (author)

  4. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    Science.gov (United States)

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future

  5. Methods of Analysis by the U.S. Geological Survey National Water Quality Laboratory - Determination of Wastewater Compounds by Polystyrene-Divinylbenzene Solid-Phase Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.; Barber, Larry B.; Burkhardt, Mark R.

    2002-01-01

    A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides. Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent ? 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

  6. Determination of haloacetic acids in water using layered double hydroxides as a sorbent in dispersive solid-phase extraction followed by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Alsharaa, Abdulnaser; Sajid, Muhammad; Basheer, Chanbasha; Alhooshani, Khalid; Lee, Hian Kee

    2016-09-01

    In the present study, highly efficient and simple dispersive solid-phase extraction procedure for the determination of haloacetic acids in water samples has been established. Three different types of layered double hydroxides were synthesized and used as a sorbent in dispersive solid-phase extraction. Due to the interesting behavior of layered double hydroxides in an acidic medium (pH˂4), the analyte elution step was not needed; the layered double hydroxides are simply dissolved in acid immediately after extraction to release the analytes which are then directly introduced into a liquid chromatography with tandem mass spectrometry system for analysis. Several dispersive solid-phase extraction parameters were optimized to increase the extraction efficiency of haloacetic acids such as temperature, extraction time and pH. Under optimum conditions, good linearity was achieved over the concentration range of 0.05-100 μg/L with detection limits in the range of 0.006-0.05 μg/L. The relative standard deviations were 0.33-3.64% (n = 6). The proposed method was applied to different water samples collected from a drinking water plant to determine the concentrations of haloacetic acids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Multiple solid-phase microextraction

    NARCIS (Netherlands)

    Koster, EHM; de Jong, GJ

    2000-01-01

    Theoretical aspects of multiple solid-phase microextraction are described and the principle is illustrated with the extraction of lidocaine from aqueous solutions. With multiple extraction under non-equilibrium conditions considerably less time is required in order to obtain an extraction yield that

  8. Multiwalled carbon nanotubes as solid-phase extraction materials for the gas chromatographic determination of organophosphorus pesticides in waters.

    Science.gov (United States)

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Angel Rodríguez-Delgado, Miguel

    2008-10-01

    In the present work, a GC method with nitrogen-phosphorus detection (NPD) was developed for the simultaneous determination of eight organophosphorus pesticide (OPP) residues (i.e., ethoprofos, diazinon, chlorpyrifos-methyl, fenitrothion, malathion, chlorpyrifos, fenamiphos, and buprofezin) in water samples. Preconcentration of the water samples was carried out using an SPE procedure with multiwalled carbon nanotubes (MWCNTs) of 10-15 nm od, 2-6 nm id, and 0.1-10 microm length as stationary phase. Extraction parameters, such as the amount of MWCNTs, sample volume, pH, and type and amount of the eluent were optimized. The most favorable conditions were as follows: 40 mg MWCNTs, 800 mL water, pH 6.0, and 20 mL dichloromethane, respectively. The MWCNTs-SPE-GC-NPD method was applied to the determination of these pesticides in real water samples: mineral and ground water as well as run-off water from an agricultural area collected shortly before opening out onto the sea. A recovery study was developed with five consecutive extractions of the three types of water spiked at three concentration levels (n = 15). Mean recovery values were in the range of 75-116% for mineral water (RSD water (RSD waters (RSDs waters, RSDs waters). The proposed method was also applied to the analysis of six water samples (two of each type: mineral, ground, and run-off waters) in which no residues of the selected pesticides were found. Results show that the MWCNTs used in this work have a high adsorbability of the pesticides under study. The main advantage of the use of these MWCNTs is their low cost when compared with those MWCNTs previously used in the literature and with conventional SPE cartridges.

  9. Novel Functionalized Polythiophene-Coated Fe3O4 Nanoparticles for Magnetic Solid-Phase Extraction of Phthalates

    Directory of Open Access Journals (Sweden)

    Siti Nor Atika Baharin

    2016-04-01

    Full Text Available Poly(phenyl-(4-(6-thiophen-3-yl-hexyloxy-benzylidene-amine (P3TArH was successfully synthesized and coated on the surface of Fe3O4 magnetic nanoparticles (MNPs. The nanocomposites were characterized by Fourier transform infra-red (FTIR, X-ray diffractometry (XRD, Brunauer-Emmett-Teller (BET surface area analysis, analyzer transmission electron microscopy (TEM and vibrating sample magnetometry (VSM. P3TArH-coated MNPs (MNP@P3TArH showed higher capabilities for the extraction of commonly-used phthalates and were optimized for the magnetic-solid phase extraction (MSPE of environmental samples. Separation and determination of the extracted phthalates, namely dimethyl phthalate (DMP, diethyl phthalate (DEP, dipropyl phthalate (DPP, dibutyl phthalate (DBP, butyl benzyl phthalate (BBP, dicyclohexyl phthalate (DCP, di-ethylhexyl phthalate (DEHP and di-n-octyl phthalate (DNOP, were conducted by a gas chromatography-flame ionization detector (GC-FID. The best working conditions were as follows; sample at pH 7, 30 min extraction time, ethyl acetate as the elution solvent, 500-µL elution solvent volumes, 10 min desorption time, 10-mg adsorbent dosage, 20-mL sample loading volume and 15 g·L−1 concentration of NaCl. Under the optimized conditions, the analytical performances were determined with a linear range of 0.1–50 µg·L−1 and a limit of detection at 0.08–0.468 µg·L−1 for all of the analytes studied. The intra-day (n = 7 and inter-day (n = 3 relative standard deviations (RSD% of three replicates were each demonstrated in the range of 3.7–4.9 and 3.0–5.0, respectively. The steadiness and reusability studies suggested that the MNP@P3TArH could be used up to five cycles. The proposed method was executed for the analysis of real water samples, namely commercial bottled mineral water and bottled fresh milk, whereby recoveries in the range of 68%–101% and RSD% lower than 7.7 were attained.

  10. Magnetic solid-phase extraction of five pyrethroids from environmental water samples followed by ultrafast liquid chromatography analysis.

    Science.gov (United States)

    Yu, Xi; Sun, Ying; Jiang, Chunzhu; Sun, Xiumin; Gao, Yan; Wang, Yuanpeng; Zhang, Hanqi; Song, Daqian

    2012-08-30

    In this study, the polystyrene-coated magnetic nanoparticles (MNPs/PSt) were successfully prepared and characterized by Fourier transform infrared spectroscopy, transmission electron microscopy and vibrating sample magnetometry. The as-prepared MNPs/PSt were used as the adsorbent in magnetic solid phase extraction of five pyrethroids, including lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin, in environmental water samples. The five pyrethroids were determined by ultra fast liquid chromatography-ultraviolet spectrometry. The influencing factors, including amount of MNPs/Pst, extraction time, pH value, type and volume of desorption solvent and desorption time, were examined and optimized. The extraction recoveries obtained with merely 50mg of MNPs/Pst were very satisfactory. The whole extraction process could be completed within 0.5h. The MNPs/PSt can be reused after an easy washing process. Thus, a simple, green, economical, time saving and effective method for pyrethroids analysis in environmental water samples was established. A high enrichment factor of 500 was achieved and the limits of detection for lambda-cyhalothrin, deltamethrin, esfenvalerate, permethrin, bifenthrin were 0.015±0.001 ng mL(-1), 0.012±0.001 ng mL(-1), 0.026±0.001 ng mL(-1), 0.020±0.001 ng mL(-1), 0.013±0.001 ng mL(-1), respectively. Recoveries obtained by analyzing spiked water samples at three concentration levels (0.100±0.001 ng mL(-1), 1.000±0.001 ng mL(-1), 10.000±0.001 ng mL(-1)) were between 78.97±8.38% and 96.05±8.38%. The standard curves for the five pyrethroids showed good linearity with the correlation coefficients in the range of 0.9994-0.9999. The intra-day and inter-day precision were satisfactory with the RSDs in the range of 2.05-5.52% and 2.73-8.38%, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Study of molecularly imprinted solid-phase extraction of gonyautoxins 2,3 in the cultured dinoflagellate Alexandrium tamarense by high-performance liquid chromatography with fluorescence detection

    International Nuclear Information System (INIS)

    Lian, Zi-Ru; Wang, Jiang-Tao

    2013-01-01

    A highly selective sample cleanup procedure combined with molecularly imprinted solid-phase extraction (MISPE) was developed for the isolation of gonyautoxins 2,3 (GTX2,3) from Alexandrium tamarense sample. The molecularly imprinted polymer microspheres (MIPMs) were prepared by suspension polymerization using caffeine as the dummy template molecule, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker and polyvinyl alcohol as the dispersive reagent. The polymer microspheres were used as a selective sorbent for the solid-phase extraction of gonyautoxins 2,3. An off-line MISPE method followed by high-performance liquid chromatography (HPLC) with fluorescence detection for the analysis of gonyautoxins 2,3 was established. Finally, the extract samples from Alexandrium tamarense were analyzed. The results showed the imprinted polymer microspheres exhibited high affinity and selectivity for gonyautoxins 2,3. The interference matrix in the extract were obviously cleaned by MISPE and the extraction efficiency of gonyautoxins 2,3 in the sample ranged from 81.74% to 85.86%. -- Graphical abstract: This is the SEM photograph of molecularly imprinted polymer microspheres (MIPMs). MIPMs were prepared by suspension polymerization and used as selective sorbents for the solid-phase extraction of gonyautoxins 2,3. An off-line MISPE method followed by high-performance liquid chromatography with fluorescence detection for the analysis of gonyautoxins 2,3 was established. The extract samples from Alexandrium tamarense were analyzed by molecularly imprinted solid-phase extraction. Highlights: •The molecularly imprinted polymer microspheres (MIPMs) for GTX2,3 were prepared. •The characteristics and regeneration property of MIPMs were studied. •An off-line method using MIPMs as solid-phase extraction (SPE) sorbents was developed. •GTX2,3 from Alexandrium tamarense extract was successfully isolated by MIPMs-SPE. -- MIPMs for GTX2,3 were

  12. Application of mercapto-silica polymerized high internal phase emulsions for the solid-phase extraction and preconcentration of trace lead(II).

    Science.gov (United States)

    Su, Rihui; Ruan, Guihua; Chen, Zhengyi; Du, Fuyou; Li, Jianping

    2015-12-01

    A new class of solid-phase extraction column prepared with grafted mercapto-silica polymerized high internal phase emulsion particles was used for the preconcentration of trace lead. First, mercapto-silica polymerized high internal phase emulsion particles were synthesized by using high internal phase emulsion polymerization and carefully assembled in a polyethylene syringe column. The influences of various parameters including adsorption pH value, adsorption and desorption solvents, flow rate of the adsorption and desorption procedure were optimized, respectively, and the suitable uploading sample volumes, adsorption capacity, and reusability of solid phase extraction column were also investigated. Under the optimum conditions, Pb(2+) could be preconcentrated quantitatively over a wide pH range (2.0-5.0). In the presence of foreign ions, such as Na(+) , K(+) , Ca(2+) , Zn(2+) , Mg(2+) , Cu(2+) , Fe(2+) , Cd(2+) , Cl(-) and NO3 (-) , Pb(2+) could be recovered successfully. The prepared solid-phase extraction column performed with high stability and desirable durability, which allowed more than 100 replicate extractions without measurable changes of performance. The feasibility of the developed method was further validated by the extraction of Pb(2+) in rice samples. At three spiked levels of 40.0, 200 and 800 μg/kg, the average recoveries for Pb(2+) in rice samples ranged from 87.3 to 105.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. A Modified Method for Determination of Lumefantrine in Human Plasma by HPLC-UV and Combination of Protein Precipitation and Solid-Phase Extraction: Application to a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Liusheng Huang

    2010-03-01

    Full Text Available An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid followed by solid-phase extraction with Hypersep C8 cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 × 150 mm, 3.5 μm with water/methanol (0.1% TFA as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at λ = 335 nm. The method showed to be linear over a range of 50–10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether—lumefantrine and antiretroviral therapy.

  14. Development and validation of a solid-phase extraction method coupled to liquid chromatography with fluorescence detection for the determination of fluoroquinolone residues in powdered infant formulae. Application to the analysis of samples from the Spanish and Latin American market.

    Science.gov (United States)

    Rodriguez, E; Moreno-Bondi, M C; Marazuela, M D

    2008-10-31

    This paper describes a new method for the effective extraction, clean-up and chromatographic analysis of residues of four fluoroquinolones (ciprofloxacin, enrofloxacin, danofloxacin and sarafloxacin) in powdered infant formulae and follow-on preparations. Samples were reconstituted following the manufacturer's recommendations and treated with trichloroacetic acid in methanol 10% (w/v) for deproteinization. Two solid-phase extraction cartridges have been evaluated for sample clean-up and preconcentration, Strata Screen A and Strata X and the later provided the best recoveries for all the analytes tested. Chromatographic analysis has been carried out using a polar endcapped column (AQUA C(18)) and fluorescence detection, with lomefloxacin (LOME) as internal standard. Method validation has been performed according to European Commission Decision 2002/657/EC criteria, in terms of linearity, recovery, precision, specificity, decision limit (CC(alpha)) and detection capability (CC(beta)). Typical recoveries ranged between 70 and 110% at levels below and above the maximum residue limits of the target analytes in bovine milk, with an excellent intralab reproducibility (RSDsmarket, using LC-MS/MS as confirmatory technique.

  15. Submicrometric Magnetic Nanoporous Carbons Derived from Metal-Organic Frameworks Enabling Automated Electromagnet-Assisted Online Solid-Phase Extraction.

    Science.gov (United States)

    Frizzarin, Rejane M; Palomino Cabello, Carlos; Bauzà, Maria Del Mar; Portugal, Lindomar A; Maya, Fernando; Cerdà, Víctor; Estela, José M; Turnes Palomino, Gemma

    2016-07-19

    We present the first application of submicrometric magnetic nanoporous carbons (μMNPCs) as sorbents for automated solid-phase extraction (SPE). Small zeolitic imidazolate framework-67 crystals are obtained at room temperature and directly carbonized under an inert atmosphere to obtain submicrometric nanoporous carbons containing magnetic cobalt nanoparticles. The μMNPCs have a high contact area, high stability, and their preparation is simple and cost-effective. The prepared μMNPCs are exploited as sorbents in a microcolumn format in a sequential injection analysis (SIA) system with online spectrophotometric detection, which includes a specially designed three-dimensional (3D)-printed holder containing an automatically actuated electromagnet. The combined action of permanent magnets and an automatically actuated electromagnet enabled the movement of the solid bed of particles inside the microcolumn, preventing their aggregation, increasing the versatility of the system, and increasing the preconcentration efficiency. The method was optimized using a full factorial design and Doehlert Matrix. The developed system was applied to the determination of anionic surfactants, exploiting the retention of the ion-pairs formed with Methylene Blue on the μMNPC. Using sodium dodecyl sulfate as a model analyte, quantification was linear from 50 to 1000 μg L(-1), and the detection limit was equal to 17.5 μg L(-1), the coefficient of variation (n = 8; 100 μg L(-1)) was 2.7%, and the analysis throughput was 13 h(-1). The developed approach was applied to the determination of anionic surfactants in water samples (natural water, groundwater, and wastewater), yielding recoveries of 93% to 110% (95% confidence level).

  16. Core-Shell Diamond as a Support for Solid-Phase Extraction and High-Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Saini, Gaurav; Jensen, David S.; Wiest, Landon A.; Vail, Michael A.; Dadson, Andrew; Lee, Milton L.; Shutthanandan, V.; Linford, Matthew R.

    2010-06-01

    We report the formation of core-shell diamond particles for solid phase extraction (SPE) and high performance liquid chromatography (HPLC) made by layer-by-layer (LbL) deposition. Their synthesis begins with the amine functionalization of microdiamond by its immersion in an aqueous solution of a primary amine-containing polymer (polyallylamine (PAAm)). The amine-terminated microdiamond is then immersed in an aqueous suspension of nanodiamond, which leads to adsorption of the nanodiamond. Alternating (self-limiting) immersions in the solutions of the amine-containing polymer and the suspension of nanodiamond are continued until the desired number of nanodiamond layers is formed around the microdiamond. Finally, the core-shell particles are cross-linked with 1,2,5,6-diepoxycyclooctane or reacted with 1,2-epoxyoctadecane. Layer-by-layer deposition of PAAm and nanodiamond is also studied on planar Si/SiO2 surfaces, which were characterized by SEM, Rutherford backscattering spectrometry (RBS) and nuclear reaction analysis (NRA). Core-shell particles are characterized by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT), environmental scanning electron microscopy (ESEM), and Brunauer Emmett Teller (BET) surface area and pore size measurements. Larger (ca. 50 μm) core-shell diamond particles have much higher surface areas, and analyte loading capacities in SPE than nonporous solid diamond particles. Smaller (ca. 3 μm), normal and reversed phase, core-shell diamond particles have been used for HPLC, with 36,300 plates per meter for mesitylene in a separation of benzene and alkyl benzenes on a C18 adsorbent, and 54,800 plates per meter for diazinon in a similar separation of two pesticides.

  17. Core-shell diamond as a support for solid-phase extraction and high-performance liquid chromatography.

    Science.gov (United States)

    Saini, Gaurav; Jensen, David S; Wiest, Landon A; Vail, Michael A; Dadson, Andrew; Lee, Milton L; Shutthanandan, V; Linford, Matthew R

    2010-06-01

    We report the formation of core-shell diamond particles for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) made by layer-by-layer (LbL) deposition. Their synthesis begins with the amine functionalization of microdiamond by its immersion in an aqueous solution of a primary amine-containing polymer (polyallylamine (PAAm)). The amine-terminated microdiamond is then immersed in an aqueous suspension of nanodiamond, which leads to adsorption of the nanodiamond. Alternating (self-limiting) immersions in the solutions of the amine-containing polymer and the suspension of nanodiamond are continued until the desired number of nanodiamond layers is formed around the microdiamond. Finally, the core-shell particles are cross-linked with 1,2,5,6-diepoxycyclooctane or reacted with 1,2-epoxyoctadecane. Layer-by-layer deposition of PAAm and nanodiamond is also studied on planar Si/SiO(2) surfaces, which were characterized by scanning electron microscopy (SEM), Rutherford backscattering spectrometry (RBS), and nuclear reaction analysis (NRA). Core-shell particles are characterized by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT), environmental scanning electron microscopy (ESEM), and Brunauer-Emmett-Teller (BET) surface area and pore size measurements. Larger (ca. 50 microm) core-shell diamond particles have much higher surface areas and analyte loading capacities in SPE than nonporous solid diamond particles. Smaller (ca. 3 microm), normal and reversed-phase, core-shell diamond particles have been used for HPLC, with 36,300 plates/m for mesitylene in a separation of benzene and alkyl benzenes and 54,800 plates/m for diazinon in a similar separation of two pesticides on a C(18) adsorbent.

  18. Synthesis and application of surface-imprinted activated carbon sorbent for solid-phase extraction and determination of copper (II)

    Science.gov (United States)

    Li, Zhenhua; Li, Jingwen; Wang, Yanbin; Wei, Yajun

    2014-01-01

    A new Cu(II)-imprinted amino-functionalized activated carbon sorbent was prepared by a surface imprinting technique for selective solid-phase extraction (SPE) of Cu(II) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of Cu(II) were optimized with respect to different experimental parameters using static and dynamic procedures in detail. Compared with non-imprinted sorbent, the ion-imprinted sorbent had higher selectivity and adsorption capacity for Cu(II). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cu(II) was 26.71 and 6.86 mg g-1, respectively. The relatively selectivity factor values (αr) of Cu(II)/Zn(II), Cu(II)/Ni(II), Cu(II)/Co(II) and Cu(II)/Pb(II) were 166.16, 50.77, 72.26 and 175.77, respectively, which were greater than 1. Complete elution of the adsorbed Cu(II) from Cu(II)-imprinted sorbent was carried out using 2 mL of 0.1 mol L-1 EDTA solution. The relative standard deviation of the method was 2.4% for eleven replicate determinations. The method was validated for the analysis by two certified reference materials (GBW 08301, GBW 08303), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace copper in natural water samples with satisfactory results.

  19. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions

    Energy Technology Data Exchange (ETDEWEB)

    Tu Zhifeng; He Qun [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Chang, Xijun, E-mail: tuzhf07@lzu.cn [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China); Hu Zheng; Gao Ru; Zhang Lina; Li Zhenhua [Department of Chemistry, Lanzhou University, Lanzhou 730000 (China)

    2009-09-07

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L{sup -1} HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g{sup -1} for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL{sup -1} for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  20. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions.

    Science.gov (United States)

    Tu, Zhifeng; He, Qun; Chang, Xijun; Hu, Zheng; Gao, Ru; Zhang, Lina; Li, Zhenhua

    2009-09-07

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL(-1) for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n=8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  1. 1-(2-Formamidoethyl)-3-phenylurea functionalized activated carbon for selective solid-phase extraction and preconcentration of metal ions

    International Nuclear Information System (INIS)

    Tu Zhifeng; He Qun; Chang, Xijun; Hu Zheng; Gao Ru; Zhang Lina; Li Zhenhua

    2009-01-01

    A novel method that utilizes 1-(2-formamidoethyl)-3-phenylurea-modified activated carbon (AC-1-(2-formamidoethyl)-3-phenylurea) as a solid-phase extractant has been developed for simultaneous preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) prior to the measurement by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of Cr(III), Cu(II), Fe(III) and Pb(II) were optimized using batch and column procedures in detail. The optimum pH value for the separation of metal ions simultaneously on the new sorbent was 4. And the adsorbed metal ions could be completely eluted by using 2.0 mL 2.0 mol L -1 HCl solution. Common coexisting ions did not interfere with the separation and determination of target metal ions. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 39.8, 39.9, 77.8 and 17.3 mg g -1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The detection limits of the method were found to be 0.15, 0.41, 0.27 and 0.36 ng mL -1 for Cr(III), Cu(II), Fe(III) and Pb(II), respectively. The relative standard deviation (RSD) of the method was lower than 4.0% (n = 8). The method was successfully applied for the preconcentration of trace Cr(III), Cu(II), Fe(III) and Pb(II) in natural and certified samples with satisfactory results.

  2. Core-Shell Diamond as a Support for Solid-Phase Extraction and High-Performance Liquid Chromatography

    International Nuclear Information System (INIS)

    Saini, Gaurav; Jensen, David S.; Wiest, Landon A.; Vail, Michael A.; Dadson, Andrew; Lee, Milton L.; Shutthanandan, V.; Linford, Matthew R.

    2010-01-01

    We report the formation of core-shell diamond particles for solid phase extraction (SPE) and high performance liquid chromatography (HPLC) made by layer-by-layer (LbL) deposition. Their synthesis begins with the amine functionalization of microdiamond by its immersion in an aqueous solution of a primary amine-containing polymer (polyallylamine (PAAm)). The amine-terminated microdiamond is then immersed in an aqueous suspension of nanodiamond, which leads to adsorption of the nanodiamond. Alternating (self-limiting) immersions in the solutions of the amine-containing polymer and the suspension of nanodiamond are continued until the desired number of nanodiamond layers is formed around the microdiamond. Finally, the core-shell particles are cross-linked with 1,2,5,6-diepoxycyclooctane or reacted with 1,2-epoxyoctadecane. Layer-by-layer deposition of PAAm and nanodiamond is also studied on planar Si/SiO2 surfaces, which were characterized by SEM, Rutherford backscattering spectrometry (RBS) and nuclear reaction analysis (NRA). Core-shell particles are characterized by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT), environmental scanning electron microscopy (ESEM), and Brunauer Emmett Teller (BET) surface area and pore size measurements. Larger (ca. 50 ?m) core-shell diamond particles have much higher surface areas, and analyte loading capacities in SPE than nonporous solid diamond particles. Smaller (ca. 3 ?m), normal and reversed phase, core-shell diamond particles have been used for HPLC, with 36,300 plates per meter for mesitylene in a separation of benzene and alkyl benzenes on a C18 adsorbent, and 54,800 plates per meter for diazinon in a similar separation of two pesticides.

  3. Comprehensive solid-phase extraction of multitudinous bioactive peptides from equine plasma and urine for doping detection.

    Science.gov (United States)

    Guan, Fuyu; Robinson, Mary A

    2017-09-08

    The ability to analyze biological samples for multitudinous exogenous peptides with a single analytical method is desired for doping control in horse racing. The key to achieving this goal is the capability of extracting all target peptides from the sample matrix. In the present study, theory of mixed-mode solid-phase extraction (SPE) of peptides from plasma is described, and a generic mixed-mode SPE procedure has been developed for recovering multitudinous exogenous peptides with remarkable sequence diversity, from equine plasma and urine in a single procedure. Both the theory and the developed SPE procedure have led to the development of a novel analytical method for comprehensive detection of multitudinous bioactive peptides in equine plasma and urine using liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Thirty nine bioactive peptides were extracted with strong anion-exchange mixed-mode SPE sorbent, separated on a reversed-phase C 18 column and detected by HRMS and data-dependent tandem mass spectrometry. The limit of detection (LOD) was 10-50 pg mL -1 in plasma for most of the peptides and 100 pg mL -1 for the remaining. For urine, LOD was 20-400 pg mL -1 for most of the peptides and 1-4 ng mL -1 for the others. In vitro degradation of the peptides in equine plasma and urine was examined at ambient temperature; the peptides except those with a D-amino acid at position 2 were unstable not only in plasma but also in urine. The developed method was successful in analysis of plasma and urine samples from horses administered dermorphin. Additionally, dermorphin metabolites were identified in the absence of reference standards. The developed SPE procedure and LC-HRMS method can theoretically detect virtually all peptides present at a sufficient concentration in a sample. New peptides can be readily included in the method to be detected without method re-development. The developed method also generates such data that can be

  4. A novel magnetic poly(aniline-naphthylamine)-based nanocomposite for micro solid phase extraction of rhodamine B

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Habib, E-mail: bagheri@sharif.edu; Daliri, Rasoul; Roostaie, Ali

    2013-09-10

    Graphical abstract: -- Highlights: •A Fe{sub 3}O{sub 4}–aniline-naphthylamine nanocomposite was prepared via a simple route. •The magnetic nanocomposite was applied for isolation of RhB from water. •The nanocomposite applicability was compared with other pristine polymers. •The method was applied for the determination of RhB in different samples. -- Abstract: A novel Fe{sub 3}O{sub 4}–poly(aniline-naphthylamine)-based nanocomposite was synthesized by chemical oxidative polymerization process as a magnetic sorbent for micro solid phase extraction. The scanning electron microscopy images of the synthesized nanocomposite revealed that the copolymer posses a porous structure with diameters less than 50 nm. The extraction efficiency of this sorbent was examined by isolation of rhodamine B, a mutagenic and carcinogenic dye, from aquatic media in dispersion mode. Among different synthesized polymers, Fe{sub 3}O{sub 4}/poly(aniline-naphthylamine) nanocomposite showed a prominent efficiency. Parameters including the desorption solvent, amount of sorbent, desorption time, sample pH, ionic strength, extraction time and stirring rate were optimized. Under the optimum condition, a linear spiked calibration curve in the range of 0.35–5.00 μg L{sup −1} with R{sup 2} = 0.9991 was obtained. The limits of detection (3S{sub b}) and limits of quantification (10S{sub b}) of the method were 0.10 μg L{sup −1} and 0.35 μg L{sup −1} (n = 3), respectively. The relative standard deviation for water sample with 0.5 μg L{sup −1} of RhB was 4.2% (n = 5) and the absolute recovery was 92%. The method was applied for the determination of rhodamine B in dishwashing foam, dishwashing liquid, shampoo, pencil, matches tips and eye shadows samples and the relative recovery percentage were in the range of 94–99%.

  5. Recovery evaluation of organophosphorus pesticides from bee pollen by matrix solid-phase dispersion extraction using sorbents based on silica and titania

    International Nuclear Information System (INIS)

    Torres-Perea, C; Muñoz-Rodríguez, D; Carrera-Figueiras, C; Medina-Peralta, S; Moguel-Ordóñez, Y B

    2013-01-01

    This work focused on the evaluation of the recovery of organophosphorus pesticides from bee pollen after matrix solid phase-dispersion extraction (MSPD). Materials based on silica, titania and titania modified with polivylnylimidazole or polyestirene were used as adsorbents for the extraction of pesticides. Small amounts of fortified pollen (0.1 g, at 1 micro-g/g of pesticides), adsorbent (0.4 g) and solvent elution (1 mL de acetonitrile – ACN) were used in the extractions. For recovery evaluation, pollen extracts were analyzed by gas chromatography coupled with mass spectrometry.

  6. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    International Nuclear Information System (INIS)

    Claude, Berengere; Nehme, Reine; Morin, Philippe

    2011-01-01

    of the FASI/CE-UV method.Therefore, a solid phase extraction (SPE) on a dedicated imprinted polymer (MIP) was developed to extract specific neurotransmitters, catecholamines, metanephrines and indolamines, from urine. Matrix salts were thus discarded after sample extraction on AFFINIMIP TM Catecholamine and Metanephrine (100 mg) cartridge. Therefore, lower limits of quantification were determined in artificial urine (46 nmol L -1 for DA, 11 nmol L -1 for 3-MT and 6 nmol L -1 for 5-HT).The application of this protocol MIP-SPE/FASI-CE-UV analysis of neurotransmitters in human urine gave rise to electropherograms with a very good base line and signal to noise ratios above 15.

  7. Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Claude, Berengere, E-mail: berengere.claude@univ-orleans.fr [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France); Nehme, Reine; Morin, Philippe [Institut de Chimie Organique et Analytique, CNRS FR 2708 UMR 6005, Universite d' Orleans, 45067 Orleans (France)

    2011-08-12

    neurotransmitters in urine, the presence of salts in the matrix greatly reduces the sensitivity of the FASI/CE-UV method.Therefore, a solid phase extraction (SPE) on a dedicated imprinted polymer (MIP) was developed to extract specific neurotransmitters, catecholamines, metanephrines and indolamines, from urine. Matrix salts were thus discarded after sample extraction on AFFINIMIP{sup TM} Catecholamine and Metanephrine (100 mg) cartridge. Therefore, lower limits of quantification were determined in artificial urine (46 nmol L{sup -1} for DA, 11 nmol L{sup -1} for 3-MT and 6 nmol L{sup -1} for 5-HT).The application of this protocol MIP-SPE/FASI-CE-UV analysis of neurotransmitters in human urine gave rise to electropherograms with a very good base line and signal to noise ratios above 15.

  8. Long-chain ionic liquid based mixed hemimicelles and magnetic dispersed solid-phase extraction for the extraction of fluorescent whitening agents in paper materials.

    Science.gov (United States)

    Wang, Qing; Qiu, Bin; Chen, Xianbo; Wang, Bin; Zhang, Hui; Zhang, Xiaoyuan

    2017-06-01

    A novel mixed hemimicelles and magnetic dispersive solid-phase extraction method based on long-chain ionic liquids for the extraction of five fluorescent whitening agents was established. The factors influenced on extraction efficiency were investigated. Under the optimal conditions, namely, the pH of sample solution at 8.0, the concentration of long chain ionic liquid at 0.5 mmol/L, the amount of Fe 3 O 4 nanoparticle at 12 mg, extraction time at 10 min, pH 6.0 of methanol as eluent, and the desorption time at 1 min, satisfactory results were obtained. Wide linear ranges (0.02-10 ng/mL) and good linearity were attained (0.9997-0.9999). The intraday and interday RSDs were 2.1-8.3%. Limits of detection were 0.004-0.01 ng/mL, which were decreased by almost an order of magnitude compared to direct detection without extraction. The present method was applied to extract the fluorescent whitening agents in two kinds of paper samples, obtaining satisfactory results. All showed results illustrated that the detection sensitivity was improved and the proposed method was a good choice for the enriching and monitoring of trace fluorescent whitening agents. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Antifouling booster biocide extraction from marine sediments: a fast and simple method based on vortex-assisted matrix solid-phase extraction.

    Science.gov (United States)

    Caldas, Sergiane Souza; Soares, Bruno Meira; Abreu, Fiamma; Castro, Ítalo Braga; Fillmann, Gilberto; Primel, Ednei Gilberto

    2018-03-01

    This paper reports the development of an analytical method employing vortex-assisted matrix solid-phase dispersion (MSPD) for the extraction of diuron, Irgarol 1051, TCMTB (2-thiocyanomethylthiobenzothiazole), DCOIT (4,5-dichloro-2-n-octyl-3-(2H)-isothiazolin-3-one), and dichlofluanid from sediment samples. Separation and determination were performed by liquid chromatography tandem-mass spectrometry. Important MSPD parameters, such as sample mass, mass of C18, and type and volume of extraction solvent, were investigated by response surface methodology. Quantitative recoveries were obtained with 2.0 g of sediment sample, 0.25 g of C18 as the solid support, and 10 mL of methanol as the extraction solvent. The MSPD method was suitable for the extraction and determination of antifouling biocides in sediment samples, with recoveries between 61 and 103% and a relative standard deviation lower than 19%. Limits of quantification between 0.5 and 5 ng g -1 were obtained. Vortex-assisted MPSD was shown to be fast and easy to use, with the advantages of low cost and reduced solvent consumption compared to the commonly employed techniques for the extraction of booster biocides from sediment samples. Finally, the developed method was applied to real samples. Results revealed that the developed extraction method is effective and simple, thus allowing the determination of biocides in sediment samples.

  10. Carbon coated magnetic nanoparticles as a novel magnetic solid phase extraction adsorbent for simultaneous extraction of methamphetamine and ephedrine from urine samples.

    Science.gov (United States)

    Taghvimi, Arezou; Hamishehkar, Hamed

    2017-01-15

    This paper develops a highly selective, specific and efficient method for simultaneous determination of ephedrine and methamphetamine by a new carbon coated magnetic nanoparticles (C/MNPs) as a magnetic solid phase extraction (MSPE) adsorbent in biological urine medium. The characterization of synthesized magnetic nano adsorbent was completely carried out by various characterization techniques like Fourier transform infrared (FT-IR) spectroscopy, powder x-ray diffraction (XRD), scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM). Nine important parameters influencing extraction efficiency including amount of adsorbent, amounts of sample volume, pH, type and amount of extraction organic solvent, time of extraction and desorption, agitation rate and ionic strength of extraction medium, were studied and optimized. Under optimized extraction conditions, a good linearity was observed in the concentration range of 100-2000ng/mL for ephedrine and 100-2500ng/mL for methamphetamine. Analysis of positive urine samples was carried out by proposed method with the recovery of 98.71 and 97.87% for ephedrine and methamphetamine, respectively. The results indicated that carbon coated magnetic nanoparticles could be applied in clinical and forensic laboratories for simultaneous determination of abused drugs in urine media. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Akram [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Alizadeh, Naader, E-mail: alizaden@modares.ac.ir [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. Black-Right-Pointing-Pointer This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. Black-Right-Pointing-Pointer Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 Multiplication-Sign 10{sup -8} to 5 Multiplication-Sign 10{sup -4} and 1.2 Multiplication-Sign 10{sup -6} to 5 Multiplication-Sign 10{sup -4} mol mL{sup -1} and the detection limit was 4 Multiplication-Sign 10{sup -8} mol L{sup -1}. The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  12. An absorbing microwave micro-solid-phase extraction device used in non-polar solvent microwave-assisted extraction for the determination of organophosphorus pesticides

    International Nuclear Information System (INIS)

    Wang Ziming; Zhao Xin; Xu Xu; Wu Lijie; Su Rui; Zhao Yajing; Jiang Chengfei; Zhang Hanqi; Ma Qiang; Lu Chunmei; Dong Deming

    2013-01-01

    Highlights: ► An absorbing microwave μ-SPE device packed with activated carbon was used. ► Absorbing microwave μ-SPE device was made and used to enrich the analytes. ► Absorbing microwave μ-SPE device was made and used to heat samples directly. ► MAE-μ-SPE was applied to the extraction of OPPs with non-polar solvent only. - Abstract: A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction (μ-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave μ-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in μ-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave μ-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 °C for 10 min. The extracts obtained by MAE-μ-SPE were directly analyzed by GC–MS without any clean-up process. The recoveries were in the range of 93.5–104.6%, and the relative standard deviations were lower than 8.7%.

  13. An absorbing microwave micro-solid-phase extraction device used in non-polar solvent microwave-assisted extraction for the determination of organophosphorus pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Wang Ziming, E-mail: wangziming@jlu.edu.cn [College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012 (China); College of Environment and Resources, Jilin University, 2699 Qianjin Street, Changchun 130012 (China); Zhao Xin; Xu Xu; Wu Lijie; Su Rui; Zhao Yajing; Jiang Chengfei; Zhang Hanqi [College of Chemistry, Jilin University, 2699 Qianjin Street, Changchun 130012 (China); Ma Qiang [Chinese Academy of Inspection and Quarantine, Beijing 100123 (China); Lu Chunmei [College of Technology Center, Jilin Entry-Exit Inspection and Quarantine Bureau, Changchun 130062 (China); Dong Deming [College of Environment and Resources, Jilin University, 2699 Qianjin Street, Changchun 130012 (China)

    2013-01-14

    Highlights: Black-Right-Pointing-Pointer An absorbing microwave {mu}-SPE device packed with activated carbon was used. Black-Right-Pointing-Pointer Absorbing microwave {mu}-SPE device was made and used to enrich the analytes. Black-Right-Pointing-Pointer Absorbing microwave {mu}-SPE device was made and used to heat samples directly. Black-Right-Pointing-Pointer MAE-{mu}-SPE was applied to the extraction of OPPs with non-polar solvent only. - Abstract: A single-step extraction-cleanup method, including microwave-assisted extraction (MAE) and micro-solid-phase extraction ({mu}-SPE), was developed for the extraction of ten organophosphorus pesticides in vegetable and fruit samples. Without adding any polar solvent, only one kind of non-polar solvent (hexane) was used as extraction solvent in the whole extraction step. Absorbing microwave {mu}-SPE device, was prepared by packing activated carbon with microporous polypropylene membrane envelope, and used as not only the sorbent in {mu}-SPE, but also the microwave absorption medium. Some experimental parameters effecting on extraction efficiency was investigated and optimized. 1.0 g of sample, 8 mL of hexane and three absorbing microwave {mu}-SPE devices were added in the microwave extraction vessel, the extraction was carried out under 400 W irradiation power at 60 Degree-Sign C for 10 min. The extracts obtained by MAE-{mu}-SPE were directly analyzed by GC-MS without any clean-up process. The recoveries were in the range of 93.5-104.6%, and the relative standard deviations were lower than 8.7%.

  14. Solid phase microextraction.

    Science.gov (United States)

    Pawliszyn, J

    2001-01-01

    Solid Phase Microextraction (SPME) uses a small volume of sorbent dispersed typically on the surface of small fibres, to isolate and concentrate analytes from sample matrix. After contact with sample, analytes are absorbed or adsorbed by the fibre phase (depending on the nature of the coating) until an equilibrium is reached in the system. The amount of an analyte extracted by the coating at equilibrium is determined by the magnitude of the partition coefficient of the analyte between the sample matrix and the coating material. After the extraction step, the fibres are transferred, with the help of a syringe-like handling device, to analytical instrument, for separation and quantitation of target analytes. This technique integrates sampling, extraction and sample introduction and is a simple way of facilitating on-site monitoring. Applications of this technique include environmental monitoring, industrial hygiene, process monitoring, clinical, forensic, food, flavour, fragrance and drug analyses, in laboratory and on-site analysis.

  15. Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packed-bed columns

    International Nuclear Information System (INIS)

    Ersoez, Arzu; Say, Ridvan; Denizli, Adil

    2004-01-01

    Solid-phase extraction (SPE) columns packed with materials based on molecularly imprinted polymers (MIPs) were used to develop selective separation and preconcentration for Ni(II) ion from aqueous solutions. SPE is more rapid, simple and economical method than the traditional liquid-liquid extraction. MIPs were used as column sorbent to increase the grade of selectivity in SPE columns. In this study, we have developed a polymer obtained by imprinting with Ni(II) ion as a ion-imprinted SPE sorbent. For this purpose, NI(II)-methacryloylhistidinedihydrate (MAH/Ni(II)) complex monomer was synthesized and polymerized with cross-linking ethyleneglycoldimethacrylate to obtain [poly(EGDMA-MAH/Ni(II))]. Then, Ni(II) ions were removed from the polymer getting Ni(II) ion-imprinted sorbent. The MIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.3 to 25 ng/ml and the detection limit was 0.3 ng/ml (3 s) for flame atomic absorption spectrometry (FAAS). Ni(II) ion-imprinted microbeads can be used several times without considerable loss of adsorption capacity. When the adsorption capacity of nickel imprinted microbeads were compared with non-imprinted microbeads, nickel imprinted microbeads have higher adsorption capacity. The K d (distribution coefficient) values for the Ni(II)-imprinted microbeads show increase in K d for Ni(II) with respect to both K d values of Zn(II), Cu(II) and Co(II) ions and non-imprinted polymer. During that time K d decreases for Zn(II), Cu(II) and Co(II) ions and the k' (relative selectivity coefficient) values which are greater than 1 for imprinted microbeads of Ni(II)/Cu(II), Ni(II)/Zn(II) and Ni(II)/Co(II) are 57.3, 53.9, and 17.3, respectively. Determination of Ni(II) ion in sea water showed that the interfering matrix had been almost removed during preconcentration. The column was good enough for Ni determination in matrixes containing similar ionic radii ions such as Cu(II), Zn(II) and Co(II)

  16. Sulfonated poly(styrene-divinylbenzene) modified with amines and the application for pipette-tip solid-phase extraction of carbendazim in apples.

    Science.gov (United States)

    Ma, Yuxin; Liu, Lingling; Tang, Weiyang; Zhu, Tao

    2017-10-01

    Sulfonated poly(styrene-divinylbenzene) modified with five kinds of amine functional groups was applied to the determination of carbendazim in apple samples with a pipette-tip solid-phase extraction method. The structures of the polymers were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis. Five different modifications of the solid-phase extraction sorbent based on sulfonated poly(styrene-divinylbenzene) were tested under static and pipette-tip solid-phase extraction conditions. The polymer modified with p-methoxyaniline showed the best recognition capacity and adsorption amount for carbendazim. Under the optimum conditions, 3.00 mg of the adsorbent, 1.00 mL of ethyl acetate as washing solvent, and 1.00 mL of ammonia/acetonitrile (5:95, v/v) as elution solvent were used in the pretreatment procedure of apple samples. The calibration graphs of carbendazim in methanol were linear over 5.00-200.00 μg/mL, and the limits of detection and quantification were 0.01 and 0.03 μg/mL, respectively. The method recoveries of carbendazim were in the range of 91.31-98.13% with associated intraday relative standard deviations of 0.76-2.13% and interday relative standard deviations of 1.10-1.85%. Sulfonated poly(styrene-divinylbenzene) modified with p-methoxyaniline showed satisfactory results (recovery: 97.96%) and potential for the rapid purification of carbendazim in apple samples combined with the pipette-tip solid-phase extraction. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Determination of Manganese, Copper, Cadmium and Lead by FAAS after Solid-Phase Extraction of Their Phenylpiperazine Dithiocarbamate Complexes on Activated Carbon

    OpenAIRE

    CESUR, Hasan

    2014-01-01

    A solid-phase extraction method was developed for the pre-concentration of manganese, copper, cadmium and lead in water samples prior to their determination by flame atomic absorption spectrometry using phenylpiperazine dithiocarbamate as a new reagent. The optimum pre-concentration conditions have been investigated such as pH, volume of sample solution and the effects of some matrix elements. The obtained recovery was nearly 90 to 100, while the enrichment factor was 400 for metal s...

  18. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS

    OpenAIRE

    Alves, Vanessa N.; Borges, Simone S. O.; Coelho, Nivia M. M.

    2011-01-01

    This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extr...

  19. Application of Solid Phase Extraction on Multiwalled Carbon Nanotubes of Some Heavy Metal Ions to Analysis of Skin Whitening Cosmetics Using ICP-AES

    OpenAIRE

    ALqadami, Ayoub; Abdalla, Mohammad; ALOthman, Zeid; Omer, Kamal

    2013-01-01

    A novel and highly sensitive method for the determination of some heavy metals in skin whitening cosmetics creams using multiwalled carbon nanotubes MWCNTs as solid phase extraction sorbent for the preconcentration of these heavy metals prior to their determination by inductively coupled plasma atomic emission spectrometry is described. Different practical parameters have been thoroughly investigated and the optimum experimental conditions were employed. The developed method was then applied ...

  20. Preparation and characterization of sodium dodecyl sulfate doped polypyrrole solid phase micro extraction fiber and its application to endocrine disruptor pesticide analysis

    OpenAIRE

    Korba, Korcan; Pelit, Levent; Okçu Pelit, Füsun; Özdokur, K. Volkan; Ertaş, Hasan; Eroğlu, Ahmet E.; Ertaş, Fatma Nil

    2013-01-01

    A robust in house solid-phase micro extraction (SPME) surface has been developed for the headspace (HS)-SPME determination of endocrine disruptor pesticides, namely, Chlorpyrifos, Penconazole, Procymidone, Bromopropylate and Lambda-Cyhalothrin in wine sample by using sodium dodecylsulfate doped polypyrrole SPME fiber. Pyrrole monomer was electrochemically polymerized on a stainless steel wire in laboratory conditions in virtue of diminishing the cost and enhancing the analyte retention on its...

  1. Pressurized liquid extraction using water/isopropanol coupled with solid-phase extraction cleanup for industrial and anthropogenic waste-indicator compounds in sediment

    Science.gov (United States)

    Burkhardt, M.R.; ReVello, R.C.; Smith, S.G.; Zaugg, S.D.

    2005-01-01

    A broad range of organic compounds is recognized as environmentally relevant for their potential adverse effects on human and ecosystem health. This method was developed to better determine the distribution of 61 compounds that are typically associated with industrial and household waste as well as some that are toxic and known (or suspected) for endocrine-disrupting potential extracted from environmental sediment samples. Pressurized liquid extraction (PLE) coupled with solid-phase extraction (SPE) was used to reduce sample preparation time, reduce solvent consumption to one-fifth of that required using dichloromethane-based Soxhlet extraction, and to minimize background interferences for full scan GC/MS analysis. Recoveries from spiked Ottawa sand, commercially available topsoil, and environmental stream sediment, fortified at 4-720 ??g per compound, averaged 76 ?? 13%. Initial method detection limits for single-component compounds ranged from 12.5 to 520 ??g/kg, based on 25 g samples. Results from 103 environmental sediment samples show that 36 out of 61 compounds (59%) were detected in at least one sample with concentrations ranging from 20 to 100,000 ??g/kg. The most frequently detected compound, beta-sitosterol, a plant sterol, was detected in 87 of the 103 (84.5%) environmental samples with a concentration range 360-100,000 ??g/kg. Results for a standard reference material using dichloromethane Soxhlet-based extraction are also compared. ?? 2004 Published by Elsevier B.V.

  2. Polyaniline-coated cigarette filters as a solid-phase extraction sorbent for the extraction and enrichment of polycyclic aromatic hydrocarbon in water samples.

    Science.gov (United States)

    Bunkoed, Opas; Rueankaew, Thanaschaphorn; Nurerk, Piyaluk; Kanatharana, Proespichaya

    2016-06-01

    Polyaniline coated cigarette filters were successfully synthesized and used as a solid-phase extraction sorbent for the extraction and preconcentration of polycyclic aromatic hydrocarbons in water samples. The polyaniline helped to enhance the adsorption ability of polycyclic aromatic hydrocarbons on the sorbent through π-π interactions. The high porosity and large surface area of the cigarette filters helped to reduce backpressure and can be operated with high sample flow rate without loss of extraction efficiency. The developed sorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The parameters that affected the extraction efficiencies, i.e. polymerization time, type of desorption solvent and its volume, sample flow rate, sample volume, sample pH, ionic strength, and organic modifier were investigated. Under the optimal conditions, the method was linear over the range of 0.5-10 μg/L and a detection limit of 0.5 ng/L. This simple, rapid, and cost-effective method was successfully applied to the preconcentration of polycyclic aromatic hydrocarbons from water samples. The developed method provided a high enrichment factor with good extraction efficiency (85-98%) and a relative standard deviation <10%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Determination of Human-Health Pharmaceuticals in Filtered Water by Chemically Modified Styrene-Divinylbenzene Resin-Based Solid-Phase Extraction and High-Performance Liquid Chromatography/Mass Spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Werner, Stephen L.; Anderson, Bruce D.; Cahill, Jeffery D.

    2008-01-01

    In 1999, the Methods Research and Development Program of the U.S. Geological Survey National Water Quality Laboratory began the process of developing a method designed to identify and quantify human-health pharmaceuticals in four filtered water-sample types: reagent water, ground water, surface water minimally affected by human contributions, and surface water that contains a substantial fraction of treated wastewater. Compounds derived from human pharmaceutical and personal-care product use, which enter the environment through wastewater discharge, are a newly emerging area of concern; this method was intended to fulfill the need for a highly sensitive and highly selective means to identify and quantify 14 commonly used human pharmaceuticals in filtered-water samples. The concentrations of 12 pharmaceuticals are reported without qualification; the concentrations of two pharmaceuticals are reported as estimates because long-term reagent-spike sample recoveries fall below acceptance criteria for reporting concentrations without qualification. The method uses a chemically modified styrene-divinylbenzene resin-based solid-phase extraction (SPE) cartridge for analyte isolation and concentration. For analyte detection and quantitation, an instrumental method was developed that used a high-performance liquid chromatography/mass spectrometry (HPLC/MS) system to separate the pharmaceuticals of interest from each other and coextracted material. Immediately following separation, the pharmaceuticals are ionized by electrospray ionization operated in the positive mode, and the positive ions produced are detected, identified, and quantified using a quadrupole mass spectrometer. In this method, 1-liter water samples are first filtered, either in the field or in the laboratory, using a 0.7-micrometer (um) nominal pore size glass-fiber filter to remove suspended solids. The filtered samples then are passed through cleaned and conditioned SPE cartridges at a rate of about 15

  5. In-line micro-matrix solid-phase dispersion extraction for