WorldWideScience

Sample records for solar test house

  1. Solar hot water systems application to the solar building test facility and the Tech House

    Science.gov (United States)

    Goble, R. L.; Jensen, R. N.; Basford, R. C.

    1976-01-01

    Projects which relate to the current national thrust toward demonstrating applied solar energy are discussed. The first project has as its primary objective the application of a system comprised of a flat plate collector field, an absorption air conditioning system, and a hot water heating system to satisfy most of the annual cooling and heating requirements of a large commercial office building. The other project addresses the application of solar collector technology to the heating and hot water requirements of a domestic residence. In this case, however, the solar system represents only one of several important technology items, the primary objective for the project being the application of space technology to the American home.

  2. Smart Solar Housing Renovation

    NARCIS (Netherlands)

    Ham, M.; Bruijn, de D.M.P.; Vos, S.J.H.; Weijers, K.A.M.; Straver, M.C.W.; Scartezzini, J.L.

    2009-01-01

    After World War II, the demand for houses in the Netherlands was enormous. Large housing construction programs were established in the fifties, sixties and seventies. Nowadays, these houses are facing some societal, economic and technological problems. On the other hand, many of the occupants are

  3. The solar house that rotates

    International Nuclear Information System (INIS)

    Miloni, R.P.

    2001-01-01

    This article describes an innovative solar building in Weiz, Austria, that uses passive solar technologies, photovoltaics and a ground-coupled heat pump to cover its minimal energy requirements. The house, which follows the sun by rotating around its central axis, is described in detail, including its climatic design and its 'plus-energy' concept. Details are also given on the materials used in the house's construction and the functioning of its thermal insulation. The various operating modes of the house from the systems point of view are described for differing seasons and climatic extremes. Marketing aspects for this standardised house, featuring personal-computer-based on-line definition of facade cladding, fittings, photovoltaic power, furnishings etc. and real-time rendering of the house are also discussed

  4. SOLAR ENERGY APPLICATION IN HOUSES HEATING SYSTEMS IN RUSSIA

    Directory of Open Access Journals (Sweden)

    Zhanna Mingaleva

    2017-06-01

    Full Text Available The solar energy is widely used around the world for electricity generation and heating systems in municipal services. But its use is complicated in the number of territories with uneven receipts of solar radiation on the earth’s surface and large number of cloudy days during a year. A hypothesis on the possibility of application of individual solar collectors for heating of houses in the number of cities of Russia has been tested. The existing designs of solar collectors and checking the possibility of their application in northern territories of Russia are investigated. The analysis was carried out taking into account features of relief and other climatic conditions of the Perm and Sverdlovsk regions. As the result of research, the basic recommended conditions for application of solar batteries in houses of the northern Russian cities have been resumed.

  5. Tomorrow's house: solar housing in 1940s America.

    Science.gov (United States)

    Barber, Daniel A

    2014-01-01

    In the years surrounding World War II, solar house heating was seen by many American architects, journal editors, and policymakers as a necessary component of the expansion into suburbia. As the technological and financial aspects of home ownership came to take on broad social implications, design strategies of architectural modernism--including the expansive use of glass, the open plan and façade, and the flexible roof line--were seen as a means to construct suburbs that were responsive to anticipated concerns over materials allocations, over energy-resource scarcity, and over the economic challenges to postwar growth. As this article demonstrates, experiments in passive solar house design were a prominent means for envisioning the suburbs as an opportunity for new kinds of building and new ways of living. The article documents these developments and places them in the context of related efforts to think about the future.

  6. Indoor Air Quality Test House

    Data.gov (United States)

    Federal Laboratory Consortium — Description:In order to enable studies of a range of indoor air quality and ventilation issues, EL maintains a highly instrumented three-bedroom test house. Previous...

  7. Solar Living House Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Bradley [Univ. of Florida, Gainesville, FL (United States)

    2017-03-09

    The Solar Living House is a high-performance solar-powered dwelling designed by a team of faculty and students from the University of Florida, in collaboration with Santa Fe College, the National University of Singapore, and Alachua Habitat for Humanity. The project was designed in accordance with the Solar Decathlon 2015, a research, design, education, and outreach program developed by the U.S. Department of Energy (DOE). The Solar Living House is fundamentally a house for living, centered on people and the activities of daily life while quietly introducing advanced design, construction, and engineering technologies. The 993 square-foot two-bedroom one-bath home was designed to embrace and frame an exterior courtyard space. This courtyard acts as an extension of the interior living spaces, maximizing the spatial potentials of a modest building footprint and introducing natural light into the primary living spaces of the house. Research Outcomes: The Solar Living House advances work on high-performance buildings through three principal technological innovations: wet/dry modular construction, a building automation system, and solar dehumidification systems. Wet / Dry Modular Construction: The house is designed as a series of five modules, including one that is designated as the “wet core.” The wet core consolidates the mechanical systems and bathroom into a single module to reduce plumbing runs, efficiency losses, and on-site construction time. The other four modules are designed to eliminate interior load bearing walls to allow for maximum flexibility in the reconfiguring of the space over time. The modules are designed to meet the structural challenges of both Florida’s hurricanes and California’s earthquakes. Building Automation System: The house is equipped with an integrated building automation system, allowing the houses environmental systems, lights, security systems, and smoke detectors to be programmed, monitored, and controlled through any mobile

  8. Energy retrofit via Social Housing: a proposal from Solar Decathlon

    Directory of Open Access Journals (Sweden)

    Chiara Tonelli

    2012-10-01

    Full Text Available Solar Decathlon is an annual university challenge where nearly zeroenergy housing prototypes enter in international competition, through a series of ten tests. The contest aims for superior energy performance, high standards of interior comfort, architectural aesthetics, positive electrical balances, industrialisation, and contained costs and feasibility as a marketable proposal. Seven editions of the Solar Decathlon have been held, with a total of 140 competing proposals both realized and placed on the market, representing a notable pool of experimental research to be studied and evaluated for applications in social housing. After a consideration of the competition features, the article describes the prototype presented by City College of New York at Solar Decathlon 2011, Washington DC, as a proposal of an energy retrofit suitable for many urban buildings with flat roofs.

  9. NexusHaus: Solar Decathlon House

    Energy Technology Data Exchange (ETDEWEB)

    Garrison, Michael Lynn [University of Texas at Austin

    2017-04-04

    The University of Texas at Austin and The Technical University of Munich 2015 Solar Decathlon house is called Nexushaus because it combines UT Austin and TUM students in an affordable modular residential green building in the context of Austin, Texas, based on shape forming principles found in nature that demonstrates transformative technologies in Zero Net Energy, Zero Net Water and Carbon Neutrality. To meet the needs of the competition, a portable modular design has been developed with an assembly that enables ease of installation and both quantitative and qualitative performance in the design. The prefabricated house sits lightly on the land and forms the superstructure for photovoltaic technologies, rainwater collection, aquaculture and permaculture gardening and indoor/outdoor living. The ultimate goal of Nexushaus is to serve as a potential prototype for a next-generation modular home that could be reproduced in mass in an assembly plant in Austin.

  10. Passive solar ranch house for the mass market

    Energy Technology Data Exchange (ETDEWEB)

    Albanes, M.N.

    1981-01-01

    To promote the building of passive solar housing in the Denver metropolitan area, a solar ranch style house was designed for a builder, Unique Homes, as part of a group of thirteen passive solar houses built for the mass market under SERI's Denver Metro Home Builders Program. The project, process of design, thermal performance analysis, cost and consumer/media response are reviewed. The final design was a direct gain, attached greenhouse system that used brick as interior mass.

  11. The SURE House (Solar Decathlon 2015)

    Energy Technology Data Exchange (ETDEWEB)

    Nastasi, John [Stevens Inst. of Technology, Hoboken, NJ (United States); May, Edwin [Stevens Inst. of Technology, Hoboken, NJ (United States)

    2017-02-21

    Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable

  12. Investigations of Intelligent Solar Heating Systems for Single Family House

    DEFF Research Database (Denmark)

    Andersen, Elsa; Chen, Ziqian; Fan, Jianhua

    2014-01-01

    Three differently designed intelligent solar heating systems are investigated experimentally in a test facility. The systems provide all the needed yearly heating demand in single family houses. The systems are based on highly stratified tanks with variable auxiliary heated volumes. The tank is a......, the control strategy of intelligent solar heating systems is investigated and the yearly auxiliary energy use of the systems and the electricity price for supplying the consumers with domestic hot water and space heating are calculated....... systems.The system will be equipped with an intelligent control system where the control of the electrical heating element(s)/heat pump is based on forecasts of the variable electricity price, the heating demand and the solar energy production.By means of numerical models of the systems made in Trnsys......Three differently designed intelligent solar heating systems are investigated experimentally in a test facility. The systems provide all the needed yearly heating demand in single family houses. The systems are based on highly stratified tanks with variable auxiliary heated volumes. The tank...

  13. Farmers' willingness to convert traditional houses to solar houses in rural areas: A survey of 465 households in Chongqing, China

    International Nuclear Information System (INIS)

    Li, Xuesong; Li, Hao; Wang, Xingwu

    2013-01-01

    In rural China, reducing low-quality fuel consumption and adopting solar technologies can mitigate pollution problems and improve farmers' living conditions. Before advising farmers to convert traditional houses to solar houses, it is necessary to understand their willingness to do so. Based on the theory of planned behaviour (TPB), this study examined nine factors related to farmers' willingness (FW). A survey was conducted in Chongqing with 465 participants. Nine hypotheses were proposed based on literature studies. A binary logistic regression model was constructed to test the data with the SPSS software package. Three of the nine factors had positive and significant impacts on FW, which were quality of life, government commitments and neighbours'/friends' assessments; two factors had negative and significant impacts, which were additional monthly out-of-pocket expenses and switching cost; and the remaining four factors had no significant impacts, which were durability, popularity, timing and local solar market maturity. Based on the findings, suggestions are made to properly introduce solar houses to Chinese farmers and to quickly stimulate market activities. - Highlights: • We study farmers' willingness to convert traditional houses to solar houses. • We have nine hypotheses and test nine associated factors. • Three factors positively and significantly impact farmers' willingness. • Other two factors negatively and significantly impact farmers' willingness. • Remaining four factors do not significantly impact farmers' willingness

  14. Long-term energy storage tanks for dwellings and solar house architecture. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-01

    The design and installation of hot water storage tanks as accumulators of solar energy is presented. Solar house architecture which maximizes roof, solar collector energy absorption potential is then considered. Proposals for residential areas which include solar houses are made.

  15. Solar heating systems for houses. A design handbook for solar combisystems

    International Nuclear Information System (INIS)

    Weiss, W.

    2003-11-01

    A handbook giving guidance on systems for providing combined solar space heating and solar water heating for houses has been produced by an international team. The guidance focuses on selection of the optimum combi-system for groups of single-family houses and multi-family houses. Standard classification and evaluation procedures are described. The book should be a valuable tool for building engineers, architects, solar manufacturers and installers of solar solar energy systems, and anyone interested in optimizing combined water and space heating solar systems

  16. Experimental study on comprehensive utilization of solar energy and energy balance in an integrated solar house

    International Nuclear Information System (INIS)

    Chang, Huawei; Liu, Yuting; Shen, Jinqiu; Xiang, Can; He, Sinian; Wan, Zhongmin; Jiang, Meng; Duan, Chen; Shu, Shuiming

    2015-01-01

    Highlights: • Active and passive solar house technology is integrated in the solar house. • Solar thermal system and solar photoelectric system are measured and analyzed. • Energy balance and energy consumption are analyzed with valuable experimental data. • “Zero energy consumption” is truly achieved with the solar supply rate of 1.19 in winter. - Abstract: An integrated solar house with numerous advanced envelops is designed and constructed to investigate the comprehensive utilization of solar energy, energy efficiency and energy balance, which combines active solar house technology with passive solar house technology including solar photovoltaic system, solar water heating system, direct-gain door and windows. Solar radiation intensity, performance of the photovoltaic system, water temperature, and indoor and outdoor temperature are measured, results of the experiments indicate that solar glass window on the south wall can maintain the average indoor temperature at 21.4 °C in the case of average outdoor temperature at 11.2 °C without any external heat supply. The output current of the solar photovoltaic system shows the same trend as solar radiation intensity. When the intensity is 619.7 W/m"2, the instantaneous generation power could reach a value of 781.9 W, cumulative capacity throughout the day achieves 4.56 kW h and photovoltaic conversion efficiency 9.8%. When the average intensity throughout a day is 358 W/m"2, the solar water heating system could help to raise the temperature of 450 L water by 30 °C with its heat collecting efficiency being 37.4%. Through the analysis of the overall energy system in the solar house, it can be derived that this solar house could achieve “zero energy consumption” in winter with the solar supply rate at 1.19.

  17. NCSU solar energy and conservation house. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1981-10-01

    A passive solar energy house has been built adjacent to the NCSU McKimmon Continuing Education Center. The house contains a two-story embedded sunspace, two Trombe walls, active solar hot water heating, thermal storage in a rock filled ceiling/floor, and numerous research treatments, and energy conservation features. (See attached photo brochure; Appendix 1). The house is completely decorated and furnished in an attractive manner and the exterior architecture is traditional and has broad consumer appeal. It is also thoroughly instrumented to monitor performance. The house is open to the public on weekends and numerous people come to visit on their own initiative and others take advantage of the close proximity to McKimmon while there attending conferences. The house will influence and motivate large numbers of people to consider solar and energy conservation facets in their homes and will provide data to substantiate performance to prospective home buyers and meaningful data on design and construction for builders.

  18. The solar house of CRESESB: seven years of success

    Energy Technology Data Exchange (ETDEWEB)

    Galdino, Marco Antonio; Souza, Hamilton Moss de, E-mail: marcoag@cepel.br

    2005-07-01

    The solar house is located in the facilities of CEPEL - Centro de Pesquisas de Energia Eletrica (Electric Power Research Centre) at Fundao Island, Rio de Janeiro, Brazil. It is powered by a stand-alone PV system and is operated by CRESESB - Centro de Referencia para Energia Solar e Eolica Sergio de Salvo Brito (Reference Centre for Solar and Wind Energy Sergio de Salvo Brito) as a demonstration centre. The solar house was built in 1997, and during seven years of operation it received about 9.000 visitors (up to middle 2004). The present paper shares some aspects of the experience gained with the solar house, including technical details of the systems installed, the experience in operation and maintenance, and the divulgation and training of personnel so far obtained. (author)

  19. Energy Analysis of a Student-Designed Solar House

    Directory of Open Access Journals (Sweden)

    Samantha Wermager

    2013-12-01

    Full Text Available This paper presents the findings from an undergraduate research project concerning the energy efficiency, consumption, and generation of a 1000 ft2 (92.9 m2 solar house. The results were compared to a home of similar size and layout, built using traditional construction methods. The solar house was modeled after the Chameleon House: Missouri University of Science and Technology’s 2013 entry in the U.S. Department of Energy Solar Decathlon. The efficiency of the design was analyzed using Energy-10 Version 1.8 software. For this comparison, a fictional American couple was created and a breakdown of their energy-use habits was recorded to accurately depict the magnitude of energy consumption. A 71% energy savings was forecasted using the Energy-10 software through the incorporation of various energy-conserving strategies in the home’s design. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The forecasted energy usage and production detailed in this report shall be used for analyzing the integrity of the design of the Chameleon House as well as future solar houses constructed by the Missouri S&T Solar House Team.

  20. Effect of solar radiation on drying house performance

    International Nuclear Information System (INIS)

    Rachmat, R.

    2000-01-01

    Solar drying is one of thermal utilization where radiation energy can be utilized efficiently. Solar drying of all sorts of agricultural products have been thoroughly studied and reported in literature, but brown rice drying system has not yet done as many as other products. The aim of the present study is to investigate the effect of solar radiation on drying house performance and brown rice drying characteristics. A construction of drying house is made from FRP sheets with 30 deg. of root slope faces southern part and inside the drying house is installed a flat bed dryer. The site of construction has 136 deg. 31.4'E in longitude and 34 deg. 43.8N in latitude with 3 m in elevation from sea level. The investigated parameters are global solar radiation, absorbed and net radiation and brown rice drying characteristics. The results showed that in unload condition, the air temperature inside drying house was higher (10 deg. C - 12 deg. C) than ambient air when there was not collector and temperature rise become higher (16 deg. C) when there was a black FRP collector inside drying house. The effect of solar radiation on temperature rise has the trend as a linear function. The heat collection efficiency of drying house with black FRP collector was two times higher (36.9 percent) than that without collector (16.3 percent). These phenomena exhibited significant result of collector utilization to the advantageous condition for a drying purpose [in

  1. Aircraft Test & Evaluation Facility (Hush House)

    Data.gov (United States)

    Federal Laboratory Consortium — The Aircraft Test and Evaluation Facility (ATEF), or Hush House, is a noise-abated ground test sub-facility. The facility's controlled environment provides 24-hour...

  2. Comparison of the solar collection efficiencies of various vinyl house

    Energy Technology Data Exchange (ETDEWEB)

    Park, K H; Shin, H N; Lee, D S; Shin, D H; Suh, K B

    1982-01-01

    Three plastic film solar dryers covered with different film layers were constructed by modifying a farm vinyl house and studying their performance. The collection efficiency and temperature raising of type C which was covered with double layers of transparent PE and black PVC film was most efficient, followed by B (which was covered with a double layer of transparent PE film) and type A (which was covered with single layer transparent PE film). The inside temperature of type C averaged 18/sup 0/C higher than ambient temperature and its collection efficiency was 31.5% with air flow rate of 3.8 m/sup 3//min. The solar energy collection efficiency of type C was increased in proportion to air flow rate up to 60.2% at 11.3 m/sup 3//min. In a demonstration drying test of red pepper in type C, drying capacity per unit area was 2.5 times higher than that of conventional solar drying on straw mat and drying time shortened to about half.

  3. Cheap type solar bioclimatic individual houses for residential areas

    Directory of Open Access Journals (Sweden)

    Mihailescu Teofil

    2016-01-01

    Full Text Available In the Romanian architectural practice for individual houses in residential areas, designing the architectural object in order to function together with the nature is neglected in the majority of the situations. This happens despite of a great variety of the solar bioclimatic solutions materialized in the traditional houses of all the Romanian geographical regions in a history of over 2000 years of traditional architecture. Unfortunately, in the local real estate realities, other choices are preferred in instead those of the solar bioclimatic architecture. The approach starts with a historical approach, analyzing several examples of traditional houses from all the regions of Romania, in order to identify the traditional bioclimatic solutions used to better adapt to the environment. This constitutes the source of inspiration for the modern cheap type solar bioclimatic houses presented. But a way of thinking should be changed for it, with the help of the Romanian state transformed in financial and legislative realities. These cheap type solar bioclimatic individual houses are destined for the middle class families and involve minimum costs for building and living, creating the best premises to efficiently use one or all of the complementary systems for producing, storage and/or transforming the energy from the environment (using solar, wind, water and/or earth energy.

  4. Simulation prototyping of an experimental solar house

    Energy Technology Data Exchange (ETDEWEB)

    Osborne, A.; Baur, S. [Department of Civil, Architectural and Environmental Engineering, Missouri University of Science and Technology, 1401 Pine Street, Rolla, MO 65409 (United States); Grantham, K. [Department of Engineering Management, Missouri University of Science and Technology, 600 W. 14th Street, Rolla, MO 65409 (United States)

    2010-06-15

    This paper presents a comparative analysis between an energy simulation model and an actual solar home. The case study used was the Team Missouri's 2009 Solar Decathlon entry. The home was evaluated using the predicted data developed with the use of Energy-10 Version 1.8. The software simulates the energy use performance of building strategies ranging from building envelope and system efficiency options. The performance data used was collected during the 2009 Solar Decathlon competition. Results comparing energy efficient strategies, consumption and generation are explored with future implications discussed. (authors)

  5. Mississauga solar house (Mississauga, Ontario, Canada)

    National Research Council Canada - National Science Library

    Sasaki, J. R

    1978-01-01

    .... Winter space heating is favoured over annual water heating. A description is given of system components, including flat plate collectors, a solar heat exchanger, a water-to-air heat pump and concrete water tanks for heat storage...

  6. Instrumentation at the Decade 80 solar house in Tucson, Arizona

    Science.gov (United States)

    1978-01-01

    Modifications, problems and solutions for the instrumentation system that occurred during the period from May through September, 1978, are described. The solar house was built to show the use of copper in home building and to demonstrate the use of solar energy to provide space heating and cooling and domestic hot water. The auxiliary energy sources are electrical resistance heating for the domestic hot water and a gas-fired boiler for space heating and operation of the adsorption air conditioning units.

  7. Performance of passive solar and energy conserving houses in California

    Science.gov (United States)

    Mahajan, S.; Newcomb, C.; Shea, M.; Mort, D.

    1983-11-01

    This report provides a technical description of the methodology and the results of a two year effort to collect field data on the performance of passive solar and energy conserving houses in California. Sixty-three passive solar houses were visited and several hours were spent with the homeowner obtaining building details, management procedures, architectural plans, photographs, and at least a year of billing data. With this information thermal performance parameters were calculated for each of the houses. Eleven of the above sixty-three Class C sites (nine passive solar and two energy conserving houses) were instrumented and monitored using the SERI Class B methodology as a guideline. Continuous data were collected for one year using up to 18 different sensors to measure temperatures, electric power, insolation, and the status of fans, gas burners, and moveable insulation. In addition careful one time measurements were made to determine the loss coefficient, infiltration rate, and furnace efficiency. Analysis of this data giving comfort conditions maintained and energy uses for a complete heating and cooling season for each of the houses is presented.

  8. Workshop - Solar cells and daylight. Solar cell house. House building with integrated solar cell systems; Workshop - Solceller og dagslys. Solcellehus. Boligbyggeri med integrerede solcelleanlaeg

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Mio; Hansen, Ellen Kathrine

    2005-04-15

    The workshop 'Solar cells and daylight' at Aarhus School of Architecture aimed at studying and developing architectural potentials of integrating solar cell systems in building components for future house building. The aim of the process was to stress that technical conditions such as energy technological component design might work as central points of support in the future shaping and organisation of qualitative and functional design of houses. (BA)

  9. National Solar Thermal Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The National Solar Thermal Test Facility (NSTTF) is the only test facility in the United States of its type. This unique facility provides experimental engineering...

  10. Simulation of solar system in a house; Simulacion de un sistema solar en una vivienda unifamiliar

    Energy Technology Data Exchange (ETDEWEB)

    Rey, F. J.; Velasco, E.; Herrero, R.; Varela, F.; Nunez, M. J.; Lopez, L. M.

    2004-07-01

    Building sustainable development make necessary the rational use of already existing Energy Resources and the use of the Renewable Energies as the Thermal Solar Energy. The technological advance of the last years has allowed the development and improvement of Solar Energy Systems. As today the Thermal Solar Energy is available technical and economically reducing the environmental impact. In the present work it has been developed a TRNSYS simulation of a thermal Solar System for Hot water consumption and Space Heating by radiant Flooring in a single house. The Thermal Solar installation Simulation allows the hour-by-hour system parameters treatment to determine the energy consumptions, yields, solar contribution etc. Also, it has been studied the Energy Qualification of the building by TRNSYS and the AEV methodology developed by the Termotecnia Department of Valladolid University ( UVA). (Author)

  11. Buying a house with solar cells. Survey among subscribers and buyers of newly built houses in Amsterdam, Netherlands

    International Nuclear Information System (INIS)

    Van Mierlo, B.; Sprengers, M.

    1995-12-01

    In a new housing estate in Amsterdam in 1995 the regional energy utility (EBA) has integrated a photovoltaic (PV) system (250 kWp) into 63 houses out of 245 houses. The parts of these owner-occupied houses with PV panels are not owned by the occupants. In order to determine which are the motives to buy solar houses and in order to analyze changes in their attitudes questionnaires were sent to potential occupants twice. First to the people who registered for the new housing project (subscribers), and second to the people who bought one of the 245 houses either with or without PV (buyers). The overall conclusion is that PV does not play an important role in the decision making process when buying a new house. It is recommended to study differences in PV preferences and opinions a few years after the buyers have moved to their new houses. 10 figs., 17 tabs., 9 refs., 3 appendices

  12. Solar retrofitting in social housing: a case study in Savona

    Directory of Open Access Journals (Sweden)

    Andrea Giachetta

    2012-10-01

    Full Text Available In relation to the social Housing’s theme, sustainable requalification interventions on the building heritage in the urban fringes dating back to the WWII postwar play an important role as those are characterized by buildings which offer poor energy performances. These interventions are potentially very effective, although at the same time they raise implementation and management issues, with which it is fundamental to confront, with a view to pursue serious housing and social policies. With this object in view, the introduction of a recently completed intervention in a social housing borough in Savona, also through the use of passive solar systems, offers suggestions and hints for reflection, due to the repeatibility of some adopted solutions and design principles.

  13. Application of solar radiation for heating and preparation of warm water in an individual house

    International Nuclear Information System (INIS)

    Kozak, Tadeeusz; Majchrzycka, Anna

    2009-01-01

    The paper is aimed at analysis of application of the solar collectors array for preparing of warm water and space heating in an individual house. Keywords: application of solar radiation, preparation of warm water, heating

  14. Standard house with integrated solar cell system. Technical final report; Typehus med integreret solcelleanlaeg. Faglig slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    The interest in solar cell technology among Danish house owners is increasing, but there are many considerations to be made before the house owner choose to install solar cells on the house. Major barriers are the solar cell systems' price and appearance. This interdisciplinary development project will show that both aesthetic and economic advantages can be derived from integrating solar cells already when the first sketches of the house are being made. In order to promote utilization of solar cells in Denmark the solutions must be attractive, both economically and aesthetically. Therefore the solar cell solutions in this project are developed in preparation for marketing both as an aesthetic expression and a high-technological, green and prestigious element. (BA)

  15. Teknologi Portable Inflated Solar Power Cold Storage House Sebagai Fasilitas Pendukung Peningkatan Produksi Dan Pemasaran Perikanan Nelayan

    Directory of Open Access Journals (Sweden)

    M. Ikhsan Setiawan

    2017-09-01

    Full Text Available Global fish production currently reaches 158 million tons with the largest number of 91.3 million tons coming from the capture fisheries sector. Export results continue to increase to 35.4 billion dollars in 2012. Portable Inflated Solar Power Cold Storage House technology as a production support facility and fishermen fisheries marketing, can be constructed and transferred to certain residential locations easily, safely, quickly and lightly (0.55 mm PVC Terpaulin. Research Methods using Experimental Method and Action Research, beginning with the development of design, manufacturing, testing and repairing of prototype. Portable Inflated Solar Power Cold Storage House included: (1 technical test the speed of manufacture, transportation, assembly, installation, disassembly of Portable Inflated Structure, (2 Solar Power Cold Storage technical test related to Solar Power and Cold Storage products according to the condition of fisherman, so the fisherman fish results obtained are hygienic, cheap and profitable. The first year to develop the design of prototype Portable Inflated Solar Power Cold Storage House, followed by making prototype and ended with a prototype trial test at Narotama University Laboratory. The results of this research were continued mass production to support the acceleration of national fish absorption that hygienic, cheap and profitable.

  16. Use of radiometer to reform and repair an old living house to passive solar one

    Science.gov (United States)

    Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi

    1994-03-01

    Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.

  17. Commissioning of the Fresno, California, Retrofit Unoccupied Test House

    Energy Technology Data Exchange (ETDEWEB)

    Stecher, D. [IBACOS, Inc., Pittsburgh, PA (United States); Imm, C. [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-06-01

    Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

  18. Community-scale solar photovoltaics: housing and public development examples

    Energy Technology Data Exchange (ETDEWEB)

    Komoto, K.

    2008-03-15

    This report for the International Energy Agency (IEA) made by Task 10 of the Photovoltaic Power Systems (PVPS) programme takes a look at community-scale photovoltaics. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. The aim of Task 10 is stated as being to enhance the opportunities for wide-scale, solution-oriented application of photovoltaics in the urban environment. This report provides examples of housing developments and incorporated townships that have integrated multiple stakeholder values into business solutions. The authors are of the opinion that builders, developers, architects and engineers need to consider orientation, aesthetics, load diversity, energy efficiency, grid infrastructure and end use. Residential and commercial building owners or occupants need to consider the design of electric services relative to loads, green image, and economic opportunities such as feed-in tariffs. Local government should give preference to granting permission to high-performance building projects. It is suggested that the finance and insurance sector consider the operational savings in overall debt allowances. System manufacturers and integrators should develop standardised systems. In the emerging PV community market, utilities are quickly gaining awareness of business opportunities. The need for professionals and skilled labour is quoted as having grown as drastically as the PV market itself.

  19. Performance of the second generation solar heating system in the solar house of the Eindhoven University of Technology

    NARCIS (Netherlands)

    Bisschops, R.W.G.; van Koppen, C.W.J.; Veltkamp, W.B.; Ouden, den C.

    1984-01-01

    Summer 1981 a new solar heating system has been installed in the Solar House at the E.U.T. The principal features of the system are Philips VTR 261 evacuated tube collectors, integration of the auxiliary heater with the (stratified water) storage and application of the new, balanced flow control

  20. Solar-Thermal Engine Testing

    Science.gov (United States)

    Tucker, Stephen; Salvail, Pat; Haynes, Davy (Technical Monitor)

    2001-01-01

    A solar-thermal engine serves as a high-temperature solar-radiation absorber, heat exchanger, and rocket nozzle. collecting concentrated solar radiation into an absorber cavity and transferring this energy to a propellant as heat. Propellant gas can be heated to temperatures approaching 4,500 F and expanded in a rocket nozzle, creating low thrust with a high specific impulse (I(sub sp)). The Shooting Star Experiment (SSE) solar-thermal engine is made of 100 percent chemical vapor deposited (CVD) rhenium. The engine 'module' consists of an engine assembly, propellant feedline, engine support structure, thermal insulation, and instrumentation. Engine thermal performance tests consist of a series of high-temperature thermal cycles intended to characterize the propulsive performance of the engines and the thermal effectiveness of the engine support structure and insulation system. A silicone-carbide electrical resistance heater, placed inside the inner shell, substitutes for solar radiation and heats the engine. Although the preferred propellant is hydrogen, the propellant used in these tests is gaseous nitrogen. Because rhenium oxidizes at elevated temperatures, the tests are performed in a vacuum chamber. Test data will include transient and steady state temperatures on selected engine surfaces, propellant pressures and flow rates, and engine thrust levels. The engine propellant-feed system is designed to Supply GN2 to the engine at a constant inlet pressure of 60 psia, producing a near-constant thrust of 1.0 lb. Gaseous hydrogen will be used in subsequent tests. The propellant flow rate decreases with increasing propellant temperature, while maintaining constant thrust, increasing engine I(sub sp). In conjunction with analytical models of the heat exchanger, the temperature data will provide insight into the effectiveness of the insulation system, the structural support system, and the overall engine performance. These tests also provide experience on operational

  1. Modelling and Control of Collecting Solar Energy for Heating Houses in Norway

    Directory of Open Access Journals (Sweden)

    Mehran Dehghan

    2017-09-01

    Full Text Available In this research, a new model was developed and modified with a combined solar heating system which works with solar radiation and electricity. In order to model the system, the outdoor temperature of the location and solar irradiance has been considered. The case study of this research has been done in Porsgrunn City in the south of Norway. The building which was modelled in this research is a passive solar building which is able to store heat by using phase change materials, which are mounted on the floor and release the heat when the temperature of the house decreases. The model of the house was designed based on some assumptions about ambient temperature, solar collector size, transmitting lines length and some specific properties like air density and specific heat. The results of this research show that a solar heating system which is working with electricity can provide a sufficient temperature for the house in winter time. With using the phase change materials in order to have a passive solar building design, an improvement in the temperature inside the house was seen. Based on the simulation results which were achieved, a solar heating system which works with electricity can be an efficient system to heat the house, especially in the winter times.

  2. Test of solar dryers in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S. [Teknologisk Institut. SolEnergiCentret, Taastrup (Denmark); Floejgaard Kristensen, E. [Danmarks JordbrugsForskning, Tjele (Denmark); Agyei, F. [FAGOD Ltd. (Ghana); Larsen, T. [Clipper Design Ltd. (Ghana); Nketiah, K.S. [FORIG (Ghana)

    2002-06-01

    The report describes the tests carried out in Ghana on three solar dryers as part of the project 'Test and Research Project into the Drying of Food and Wood Products with Solar Heat' financed by DANIDA. The main objective of the project was to develop and test solar dryers for crop, fish and wood in Ghana. Three dryers were erected: 1. Solar crop dryer: The solar crop dryer was erected at Silwood Farms at Pokuase about 30 km north of Accra. Silwood Farms grows primarily maize for seed and pineapples, 2. Solar fish dryer: The solar fish dryer was erected at Elite Enterprise Ltd. at Tema about 35 km east-north-east of Accra. Elite Enterprise Ltd. buys and dries fish, 3. Solar wood dryer: The solar wood dryers were erected at Clipper Design Ltd. at Mankoadze about 65 km west-south-west of Accra. Clipper Design Ltd. produces mainly doors. (BA)

  3. Solar House Obdach: experiences with a solar ground-coupled storage system

    Energy Technology Data Exchange (ETDEWEB)

    Bruck, M; Blum, P; Held, E; Aranovitch, E; Hardacre, A G; Ofverholm, E [eds.

    1982-09-14

    Within the framework of the Solar House Obdach-project, a system consisting of a ground heat exchanger, a low-temperature collector, a water-glycol/water heat pump and a low-temperature heating system was examined with regard to its suitability as only heat source of a house. With the design chosen (1 m/sup 2/ ground collector area and 0.3 m/sup 2/ low-temperature collector area per 80 W load), a seasonal performance factor of 2.83 could be obtained. About 40% of the low-temperature heat supplied to the heat pump were delivered directly or indirectly (by means of short-term storage in the ground) by the low-temperature collector, whereas about 60% came from the natural sources of energy of the ground (air heat, radiation, precipitation, ground water and slope water). The results obtained are used to verify and improve a computer model design program for ground collectors and ground-coupled storage systems which should help to optimize the design of solar plants, particularly under difficult conditions.

  4. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-01-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof

  5. Can passive house be the solution to our energy problems, and particularly with solar energy?

    OpenAIRE

    Merciadri, Luca

    2007-01-01

    A description about the main characteristics of the passive house concept. The aim of this document is to answer to the question ``Can passive house be the solution to our energy problems, and particularly with solar energy ?'' in an objective way.

  6. Application of solar energy in houses in Tilburg, Netherlands. Final report

    International Nuclear Information System (INIS)

    Janssen, J.M.

    1995-10-01

    The options to use solar energy for housing corporations, private renters, active associations of owners and owner-occupants in Tilburg, Netherlands, are outlined. Special attention is paid to the application of solar water heaters, because of their possibility to contribute to a sustainable energy supply

  7. BIM-Integration of solar thermal systems in early housing design

    OpenAIRE

    Bonilla Castro, Alejandro; García Alvarado, Rodrigo

    2017-01-01

    Abstract: This paper sets a methodology to integrate solar thermal systems in BIM-software for the early architectural design of single houses in Concepción, Chile, using parametric families, programming in Dynamo, energy calculation with LadyBug and piping design in MEP. The results obtained allowed to select products, insert and adapts automatically the parametric designs into the model, as well as to identify changes in the type and number of solar components when the solar orientation of ...

  8. Optimizing Re-planning Operation for Smart House Applying Solar Radiation Forecasting

    Directory of Open Access Journals (Sweden)

    Atsushi Yona

    2014-08-01

    Full Text Available This paper proposes the re-planning operation method using Tabu Search for direct current (DC smart house with photovoltaic (PV, solar collector (SC, battery and heat pump system. The proposed method is based on solar radiation forecasting using reported weather data, Fuzzy theory and Recurrent Neural Network. Additionally, the re-planning operation method is proposed with consideration of solar radiation forecast error, battery and inverter losses. In this paper, it is assumed that the installation location for DC smart house is Okinawa, which is located in Southwest Japan. The validity of proposed method is confirmed by comparing the simulation results.

  9. Absorption heat pump for a potable water supply in a solar house

    Energy Technology Data Exchange (ETDEWEB)

    Elshamarka, S [Military Technical Coll., Cairo (EG)

    1991-01-01

    Solar houses usually have good potential in arid areas. These areas often suffer from not only a shortage of conventional energy sources, but also of potable water supplies. In this study, a solar air-conditioning system including an absorption heat pump, already in production since the early 1980s, is described for potable water production while performing its air-conditioning duty in a solar house. Compiled weather-conditions of the Hurgada area, on the Red Sea coast of Egypt, were employed for the prediction of the system's productivity, if it were installed in such a locality. An evaluation of the system's feasibility has been conducted. (author).

  10. Energy Efficient Industrialized Housing Research Program, Center for Housing Innovation, University of Oregon and the Florida Solar Energy Center

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.Z.

    1990-01-01

    This research program addresses the need to increase the energy efficiency of industrialized housing. Two research centers have responsibility for the program: the Center for Housing Innovation at the University of Oregon and the Florida Solar Energy Center, a research institute of the University of Central Florida. The two organizations provide complementary architectural, systems engineering, and industrial engineering capabilities. In 1989 we worked on these tasks: (1) the formation of a steering committee, (2) the development of a multiyear research plan, (3) analysis of the US industrialized housing industry, (4) assessment of foreign technology, (5) assessment of industrial applications, (6) analysis of computerized design and evaluation tools, and (7) assessment of energy performance of baseline and advanced industrialized housing concepts. The current research program, under the guidance of a steering committee composed of industry and government representatives, focuses on three interdependent concerns -- (1) energy, (2) industrial process, and (3) housing design. Building homes in a factory offers the opportunity to increase energy efficiency through the use of new materials and processes, and to increase the value of these homes by improving the quality of their construction. Housing design strives to ensure that these technically advanced homes are marketable and will meet the needs of the people who will live in them.

  11. The Modern Solar House: Architecture, Energy, and the Emergence of Environmentalism, 1938--1959

    Science.gov (United States)

    Barber, Daniel A.

    This dissertation describes the active discourse regarding solar house heating in American architectural, engineering, political, economic, and corporate contexts from the eve of World War II until the late 1950s. Interweaving these multiple narratives, the aim of the project is threefold: to document this vital discourse, to place it in the context of the history of architecture, and to trace through it the emergence of a techno-cultural environmentalism. Experimentation in the solar house relied on the principles of modern architecture for both energy efficiency and claims to cultural relevance. A passive "solar house principle" was developed in the late 30s in the suburban houses of George Fred Keck that involved open plans and flexible roof lines, and emphasized volumetric design. Spurred by wartime concern over energy resource depletion, architectural interest in solar heating also engaged an engineering discourse; in particular, an experimental program at the Massachusetts Institute of Technology led to four solar houses and a codification of its technological parameters. Attention to the MIT projects at the UN and in the Truman and Eisenhower administrations placed the solar house as a central node in an emergent network exploring the problems and possibilities of a renewable resource economy. Further experimentation elaborated on connections between this architecturalengineering discourse and the technical assistance regimes of development assistance; here by MIT researcher Maria Telkes, who also collaborated, at different junctures, with the architects Eleanor Raymond and Aladar Olgyay. The solar house discourse was further developed as a cultural project in the 1958 competition to design a solar heated residence, "Living With the Sun," which coalesced the diverse formal tendencies of midcentury modernism to promote the solar house as an innovation in both lifestyle and policy. Though the examples described are not successful as either technological

  12. New solar components studied in an experimental solar house in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Trimboli, A [IBESA (ES); Cusido, J A; Puigdomenech, J [Escola Tecnica Superior d' Arquitectura del Valles, Barcelona (ES)

    1990-09-01

    A prototype experimental solar building has been built in the School of Architecture of Valles, Spain. Its final design takes advantage of beneficial climatic effects in order to maintain indoor thermal comfort and to lower auxiliary energy usage. The building has 100 sq m of usable surface, 55 sq m of which are habitable. The remaining area is a greenhouse which is intended for experimental hydroponic cultivation. One of the main features is a thermal regulation system named the ''thermal shield''. This device, placed on the South facade of the building, is composed of a series of plastic translucent layers. Fan-forced air passes through the outer layer and circulates through the special recticular structure of the building to provide daytime heating. A heat absorbing fluid circulating through the innermost layer transfers heat via an exchanger to a storage tank of eutectic salts. The diurnal stored energy can be retrieved to heat the house at night. The thermal shield, which is computer controlled, can also be used to reduce solar gains in summer. (author).

  13. Fiscal 1994 research report. Demonstration test for establishing technology for peakload shaving with dispersed small residential PV systems (Evaluation of weatherability of house-use solar light electric power generating system equipment); 1994 nendo jutakuyo taiyoko hatsuden fuka heijunka gijutsu nado kakuritsu jissho shiken ni kansuru kaiseki hyoka no uchi jutakuyo taiyoko hatsuden system kiki no taikosei hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-03-01

    Weatherability tests such as exposure to the atmosphere are conducted to collect and accumulate information on the degradation of house-use photovoltaic equipment expected to come into use in areas where weather conditions are hostile. Based on the thus collected data, analysis and evaluation are conducted about the mechanisms of corrosion and degradation for the establishment of designing and evaluating methods for maintaining weatherability. Since fiscal 1994 is the first year of the project, preparations are made for tests to be conducted. In carrying out research activities, a Weatherability Evaluation Committee for House-Use Solar Light Electric Power Generating System Equipment is organized, who discuss implementation of the project. Discussion is made on the shape and structural materials of the exposure rack. An aluminum alloy coated with a clear coating of alumite sulfate is selected, and a rack is built. Specifications of a sea salt particle collector are discussed, and preparations are made for arresting and quantifying sea salt particles under the Japanese Industrial Standard (JIS) dry gauze method and the International Organization for Standardization (ISO) wet candle method. Solar cell module initial characteristics are measured. (NEDO)

  14. Planning of solar heated plant for low-energy houses and passive houses. An introduction; Planlegging av solvarmeanlegg for lavenergiboliger og passivhus. En introduksjon

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, Inger

    2008-07-01

    This guide gives an introduction to the most important principles in planning and projecting of solar heated plant in low-energy houses and passive houses. It is written mainly for architects and consultants involved in housing projects with ambitions to achieve low-energy or passive house standard, but will also be of value for builders and others interested in the topic. (AG). 35 refs., 27 figs

  15. Prototype solar house. Study of the scientific evaluation and feasibility of a research and development project

    Science.gov (United States)

    Bundschuh, V.; Grueter, J. W.; Kleemann, M.; Melis, M.; Stein, H. J.; Wagner, H. J.; Dittrich, A.; Pohlmann, D.

    1982-08-01

    A preliminary study was undertaken before a large scale project for construction and survey of about a hundred solar houses was launched. The notion of solar house was defined and the use of solar energy (hot water preparation, heating of rooms, heating of swimming pool, or a combination of these possibilities) were examined. A coherent measuring program was set up. Advantages and inconveniences of the large scale project were reviewed. Production of hot water, evaluation of different concepts and different fabrications of solar systems, coverage of the different systems, conservation of energy, failure frequency and failures statistics, durability of the installation, investment maintenance and energy costs were retained as study parameters. Different solar hot water production systems and the heat counter used for measurements are described.

  16. Study on indoor pollution by microbes grown in a solar house in Tokyo; Tokyo no solar house ni okeru kabi no jittai chosa

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Aihara, M; Nakanishi, R; Ito, H [Ochanomizu University, Tokyo (Japan)

    1997-11-25

    Indoor pollution by microbes grown in a solar house is studied. It is a reinforced concrete building, having a total floor area of 260m{sup 2}, equipped with a flat type solar collector on the roof and a lighting window on the north, the former having an area of 16m{sup 2} and slanted at 60deg and the latter slanted at 60deg. It is also provided with a semi-underground room, to utilize heat capacity of soil for coolness in summer and warmness in winter. It provides a residential space throughout the year, with no artificial heating or air-conditioning system, naturally ventilated with air taken into the underground room and released out of a triangular shape on the roof. The building is also passively conditioned, being totally insulated with expanded polystyrene. Energy saving is the most important consideration for the solar house, slightly forcing the residents to exercise patience. For this reason, the solar house often smells musty, and pollution with microbes is quantitatively investigated. Microbes evolve more in the underground room than in the space above groun, because of higher humidity in the former. Accelerated ventilation or slight artificial air-conditioning will solve the trouble. 1 refs., 7 figs.

  17. Possible schemes for solar-powered air-conditioning in 2-storey terrace houses

    International Nuclear Information System (INIS)

    Chu, C.M.; Bono, A.; Prabhakar, A.

    2006-01-01

    Space cooling is required all year round in the tropics, and probably accounts for a considerable proportion of the cost of electricity. Solar radiation can be channeled into cooling by photovoltaic powered systems and through the relatively new adsorption cycle technology. Two-storey terrace housing appear to have the greatest potential of introducing solar-powered cooling to residential homes. There are two schemes to cool a two-storey terrace housing: 1) By spraying water down the roof a tank, circulated by a pump powered by PV panels on the roof or 2) By replacing the roof with solar hot water collectors and use adsorption cooling chillers to produce air-conditioning for the entire block of terrace houses. In scheme number 1, a preliminary, rough technical evaluation showed that it is possible to pump water to the roof to flow down as a thin film and cool the roof by evaporation to about 40 degree C from about 70 degree C if without water evaporation at the highest insolation rate of the day. Scheme number 2, which uses adsorption chilling technology, requires communal sharing of the air-conditioning facility. The effect of collecting solar heat using the roof is two fold: to absorb solar energy for producing hot water and reducing excess heat input to the house. Preliminary costing demonstrates that solar-powered air-conditioning is within reach of commercialisation, bearing in mind that bulk purchases will dramatically lower the price of a product

  18. Outgassing tests on iras solar panel samples

    Science.gov (United States)

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  19. Performance test for a solar water heater

    Science.gov (United States)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  20. An Appalachian House: The Design and Analysis of a Passive Solar House

    OpenAIRE

    Rogers, Robin Elaine

    1999-01-01

    This project is a proposal for the design of a house situated on a plot of land within the town limits of Blacksburg. It incorporates ideas drawn from many sources, particularly from this region of Appalachia -- its geology, architectural heritage, building materials, history, Blacksburg's Comprehensive Plan, housing, agriculture and energy resources. An introduction discusses some ideas on architecture followed by chapters which provide the basis upon which the design was developed, then a d...

  1. Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Olesen, Bjarne W.

    Present work addresses the heating, cooling and ventilation concerns of the Technical University of Denmark’s house, Fold, for Solar Decathlon Europe 2012. Various innovative approaches are investigated, namely, utilization of ground, photo-voltaic/thermal (PV/T) panels and phase change materials...... (PCM). The ground heat exchanger acts as the heat sink and heat source for cooling and heating seasons, respectively. Free cooling enables the same cooling effect to be delivered with 8% of the energy consumption of a representative chiller. The heating and cooling needs of the house are addressed...... by the embedded pipes which are coupled with the ground. Ventilation is mainly used to control the humidity and to remove sensory and chemical pollution. PV/T panels enable the house to be a “plus” energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively...

  2. Marketing energy-efficient solar houses: A method to locate and identify people who will buy energy-efficient solar houses, or related services

    International Nuclear Information System (INIS)

    D'Alessio, G.

    1999-01-01

    Houses built in New England within the last six years, equal to or exceeding energy-efficiency standards from Energy Crafted Homes (ECH) or from DOE's Energy Star Homes are termed energy-efficient for this study. An assumption is that people who purchase houses being newly constructed may request special features including more energy-efficient features. The average house being constructed today is not as energy-efficient as it could easily be; therefore, owners of recently constructed energy-efficient houses may be termed early-adopters of an innovation. It has been demonstrated that early adopters have different personal attitudes and perceptions of an innovation compared to later-adopters. Both types of adopters--owners of recently constructed energy-efficient or energy-inefficient houses, have been surveyed in New England to determine whether their differences are significant enough to be used in identifying future potential early-adopters. Solar houses also are usually energy-efficient, and should be termed an innovation

  3. Solar exposure of sunglasses: aging test display

    Science.gov (United States)

    Gomes, L. M.; Masili, M.; Momesso, G. A.; Silva, F. M.; Ventura, L.

    2018-02-01

    In previous studies conducted in our lab, we have been investigating the aging effects on sunglasses. Some preliminary results have been indicating changes on the UV protection on the lenses. Therefore, besides irradiating the samples with a proper sun simulator, we have also been concerned on exposing the sunglasses to natural sun for further investigation and comparisons. Thus, this project aims expose the lenses for 24 months using an automatic solar exposition station, which consists of a series of 5 panels, housing 60 lenses arranged in the vertical position to the ground, which will be irradiated by the sun from sunrise until sunset. A box structure moves along a rail, driven by a motor and then the lenses are exposed. Humidity, rain, temperature, dust and UV index sensors, as well as a video camera are part of the system. The exposure time and UV index will be recorded and automatic opening or closing the box system may also be controlled by a PC using a webserver. The system was tested in working conditions, i.e. exposed to the weather and being automatically controlled, for five months to certifying that the samples could be exposed without being damaged. The next step of the research is to start the exposition cycles and to measure the expected transmittance variations after each cycle.

  4. Accelerated Solar-UV Test Chamber

    Science.gov (United States)

    Gupta, A.; Laue, E. G.

    1984-01-01

    Medium-pressure mercury-vapor lamps provide high ratio of ultraviolet to total power. Chamber for evaluating solar-ultraviolet (UV) radiation damage permits accelerated testing without overheating test specimens.

  5. Solar electric and thermal conversion system in close proximity to the consumer. [solar panels on house roofs

    Science.gov (United States)

    Boeer, K. W.

    1975-01-01

    Solar cells may be used to convert sunlight directly into electrical energy and into lowgrade heat to be used for large-scale terrestrial solar-energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). Cadmium-sulfide/copper-sulfide (CdS/Cu2S) solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, and stability of performance, are discussed. Systems-design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental house of the University of Delaware, are given. Economic aspects are discussed. Different modes of operation are discussed in respect to the power utility and consumer incentives.

  6. Analysis of Solar Chimneys in Different Climate Zones - Case of Social Housing in Ecuador

    Science.gov (United States)

    Godoy-Vaca, Luis; Almaguer, Manuel; Martínez-Gómez, Javier; Lobato, Andrea; Palme, Massimo

    2017-10-01

    The aim of this research is to simulate the performance of a solar chimney located in different macro-zones in Ecuador. The proposed solar chimney model was simulated using a python script in order to predict the temperature distribution and the mass flow over time. The results obtained were firstly compared with experimental data for dry-warm climate. Then, the model was evaluated and tested in real weather conditions: dry-warm, moist-warm and rainy-cold. In addition, the assumed chimney dimensions were chosen according to the literature for the studied conditions. In spite of evaluating the best nightly ventilation, different chimney wall materials were tested: solid brick, common brick and reinforced concrete. The results showed that concrete in a dry-warm climate, a metallic layer on the gap with solid brick in a moist-warm climate and reinforced concrete in a rainy cold climate used for the absorbent wall improve the thermal inertia of the social housing.

  7. Performance optimization of evacuated tube collector for solar cooling of a house in hot climate

    Science.gov (United States)

    Ghoneim, Adel A.

    2018-02-01

    Evacuating the space connecting cover and absorber significantly improves evacuated tube collector (ETC) performance. So, ETCs are progressively utilised all over the world. The main goal of current study is to explore ETC thermal efficiency in hot and severe climate like Kuwait weather conditions. A collector test facility was installed to record ETC thermal performance for one-year period. An extensively developed model for ETCs is presented, employing complete optical and thermal assessment. This study analyses separately optics and heat transfer in the evacuated tubes, allowing the analysis to be extended to different configurations. The predictions obtained are in agreement with experimental. The optimum collector parameters (collector tube length and diameter, mass flow rate and collector tilt angle) are determined. The present results indicate that the optimum tube length is 1.5 m, as at this length a significant improvement is achieved in efficiency for different tube diameters studied. Finally, the heat generated from ETCs is used for solar cooling of a house. Results of the simulation of cooling system indicate that an ETC of area 54 m2, tilt angle of 25° and storage tank volume of 2.1 m3 provides 80% of air-conditioning demand in a house located in Kuwait.

  8. TaC Studios New Construction Test House

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Curtis, O. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Kim, E. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Roberts, S. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States); Stephenson, R. [NAHB Research Center Industry Partnership, Upper Marlboro, MD (United States)

    2013-03-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate zone. This home will serve as a model home for the builder partner and addresses Building America energy savings targets through the planning and implementation of a design package will serve as a basis of design for the builder partner’s future homes. As a BA test house, this home will be evaluated to detail whole house energy use, end use loads, and HVAC and hot water efficiency.

  9. THE USE OF PASSIVE SOLAR HEATING SYSTEMS AS PART OF THE PASSIVE HOUSE

    Directory of Open Access Journals (Sweden)

    Bryzgalin Vladislav Viktorovich

    2018-05-01

    Full Text Available Subject: systems of passive solar heating, which can, without the use of engineering equipment, capture and accumulate the solar heat used for heating buildings. Research objectives: study of the possibility to reach the passive house standard (buildings with near zero energy consumption for heating in climatic conditions of Russia using the systems of passive solar heating in combination with other solutions for reduction of energy costs of building developed in the past. Materials and methods: search and analysis of literature, containing descriptions of various passive solar heating systems, examples of their use in different climatic conditions and the resulting effect obtained from their use; analysis of thermophysical processes occurring in these systems. Results: we revealed the potential of using the solar heating systems in the climatic conditions of parts of the territories of the Russian Federation, identified the possibility of cheaper construction by the passive house standard with the use of these systems. Conclusions: more detailed analysis of thermophysical and other processes that take place in passive solar heating systems is required for creation of their computational models, which will allow us to more accurately predict their effectiveness and seek the most cost-effective design solutions, and include them in the list of means for achieving the passive house standard.

  10. Developing a solar panel testing system

    Directory of Open Access Journals (Sweden)

    Árpád Rácz

    2009-10-01

    Full Text Available Solar energy is increasingly used togenerate electricity for individual households. There isa wide variety of solar panel technologies, whichshould be tested at an individual level during theirlifetime. In this paper, the development of a testingstation at the University of Debrecen is presented. Thetesting system can be used for research andeducational purposes and for in field applicationsequally well.

  11. evaluation of a modified passive solar housing system for poultry

    African Journals Online (AJOL)

    User

    The hourly efficiency of the solar brick passive system was estimated at about 78.42% in a day of May and ... to high cost and unavailability of kerosene in most developing .... sulted in intermittent rainfall, cloud cover and sunshine. From the ...

  12. Information campaign on solar heating for houses heated by electricity

    International Nuclear Information System (INIS)

    West, M.

    1995-09-01

    A number of NESA's (Danish electric power company) customers were offered the use of a solar water heating system for a short period of time. NESA was responsible for the marketing and consultancy service and worked in cooperation with local plumbers in connection with the delivery of the systems. The company contacted 450 households and its representatives visited 25 of these. 4 customers decided to purchase a solar heating system, fourteen decided to think about it, and four declared that they would not buy one. The company had reckoned with 25 purchases. It is concluded that the price of the solar heating systems was too high for prospective customers and the fact that they were not given a special offer had a negative effect. The economic aspect was absolutely the most important for them, especially the length of the payback period on the higher purchase system. Environmental protection aspects came second in their deliberations. NESA has a positive attitude to their customers' use of solar heating plants and recommends that households are offered very high quality consultancy services in connection with marketing. The project is described in detail. (AB)

  13. Test and analysis of four solar cookers; Analise e teste de quatro fogoes solares

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Paulo Cesar da Costa [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica], e-mail: PauloCPinheiro@ufmg.br, e-mail: pinheiro@demec.ufmg.br

    2006-07-01

    Solar cookers are an alternative to cooking, milk pasteurization and water purification. This paper describes the assemblage and operational data of 4 solar cookers, two greenhouse type and two concentrator type. It is also propose a methodology for solar cookers tests. (author)

  14. Solar panel acceptance testing using a pulsed solar simulator

    Science.gov (United States)

    Hershey, T. L.

    1977-01-01

    Utilizing specific parameters as area of an individual cell, number in series and parallel, and established coefficient of current and voltage temperature dependence, a solar array irradiated with one solar constant at AMO and at ambient temperature can be characterized by a current-voltage curve for different intensities, temperatures, and even different configurations. Calibration techniques include: uniformity in area, depth and time, absolute and transfer irradiance standards, dynamic and functional check out procedures. Typical data are given for individual cell (2x2 cm) to complete flat solar array (5x5 feet) with 2660 cells and on cylindrical test items with up to 10,000 cells. The time and energy saving of such testing techniques are emphasized.

  15. Solar house in Altnau; Solarhaus Haeni - Ruf Altnau

    Energy Technology Data Exchange (ETDEWEB)

    Brune, F.; Dransfeld, P.

    2005-07-01

    In this illustrated final report for the Swiss Federal Office of Energy (SFOE), a single-family home built to low-energy consumption standards is described. The building features a very low annual energy consumption that is met using renewable forms of energy. The heating demands are met using vacuum-solar collectors on the building's flat roof and by a wood-fired oven. The construction of the building is described and plans are provided. Building technical services and a measurement system installed to monitor temperatures and other factors in the building's systems are described. Twelve monthly charts of the various temperature and humidity factors measured are presented. The results of the measurements are discussed.

  16. The solarisation of welfare housing: Is passive solar design a boon to those who don`t choose it?

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T. [Australian National Univ., Canberra, ACT (Australia)

    1994-12-31

    The solarized housing built for what is now the ACT Housing Trust in Canberra in the early 1980`s is revisited to see what lessons can be learned. Several hundred solarized (solar efficient) houses were built by the Federal Government and were the first `passive solar` public housing in Australia. Some houses, due to a combination of slope and expansive soil foundations, were constructed with foil-insulated suspended timber floors instead of concrete slabs and thus had negligible effective thermal mass irrespective of the floor finish chosen by the tenant. It is apparent that many occupants of the early solarized dwellings revisited are not getting the full measure of energy savings and enhanced comfort that the designs allow. In several cases, occupant action in building out their own solar access indicates a low or possible even negative value is placed on their solar heating capabilities. Alternatively, it may indicate that the conceptual extension of living spaces onto a northerly patio, an integral part of many of the original designs, is so attractive as to tempt the owners into extending the roof in translucent material to protect the pleasurable times they have there. This post-occupancy evaluation suggests that acceptance of solar housing should be more closely examined to ensure that future low energy designs fully accommodate the preferred living patterns and needs of their target audience and that further attempts at occupant education are effective in reducing actual home energy consumption. (author). photos. 2 refs.

  17. Design, construction, and testing of a residential solar heating and cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Ward, D.S.; Loef, G.O.G.

    1976-06-01

    The NSF/CSU Solar House I solar heating and cooling system became operational on 1 July 1974. During the first months of operation the emphasis was placed on adjustment, ''tuning,'' and fault correction in the solar collection and the solar/fuel/cooling subsystems. Following this initial check out period, analysis and testing of the system utilizing a full year of data were accomplished. This report discusses the results of this analysis of the full year of operation. (WDM)

  18. TaC Studios New Construction Test House

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T.; Curtis, O.; Kim, E.; Roberts, S.; Stephenson, R.

    2013-03-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate zone. This home will serve as a model home for the builder partner and addresses Building America energy savings targets through the planning and implementation of a design package will serve as a basis of design for the builder partner's future homes. As a BA test house, this home will be evaluated to detail whole house energy use, end use loads, and HVAC and hot water efficiency.

  19. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-12-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof-mounted photovoltaic modules. The modules are fixed on special cradles which fold at night to expose the roof to the night sky, thereby enhancing night-time cooling, which is substantial in the desert environment. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. Application to a typical Middle-Eastern desert site reveals that indeed such a design is feasible with present-day technology; and should be even more attractive with future advances in technology. © 2011 Copyright Taylor and Francis Group, LLC.

  20. Survey of solar thermal test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Masterson, K.

    1979-08-01

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilities is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.

  1. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  2. Reduction of carbon dioxide emissions by solar water heating systems and passive technologies in social housing

    International Nuclear Information System (INIS)

    Bessa, Vanessa M.T.; Prado, Racine T.A.

    2015-01-01

    Growing global concern regarding climate change motivates technological studies to minimize environmental impacts. In this context, solar water heating (SWH) systems are notably prominent in Brazil, primarily because of the abundance of solar energy in the country. However, SWH designs have not always been perfectly developed. In most projects, the installation option of the solar system only considers the electric power economy aspects and not the particular characteristics of each climatic zone. Thus, the primary objective of this paper is to assess the potential of carbon dioxide reduction with the use of SWH in comparison with electric showers in social housing in several Brazilian climatic zones. The Brazilian government authorities have created public policies to encourage the use of these technologies primarily among the low-income population. The results of this paper indicate that hot climactic regions demonstrate a low reduction of CO 2 emissions with SWH installations. Thus, solar radiation is not useful for water heating in those regions, but it does lead to a large fraction of household cooling loads, implying a demand for electrical energy for air conditioning or requiring the adoption of passive techniques to maintain indoor temperatures below threshold values. -- Graphical abstract: Display Omitted -- Highlights: •Brazil has created public policies to increase the use of solar water heating in social housing. •We have evaluated the potential for reduction of CO 2 emissions installing solar water heating. •We have found that the coldest regions have the greatest potential for reducing emissions. •Passive technologies for thermal comfort in hot climate households are more useful than solar water heating systems

  3. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  4. Development, testing, and certification of Calmac Mfg. Corp. solar collector and solar operated pump

    Science.gov (United States)

    Parker, J. C.

    1979-01-01

    Development of a rubber tube solar collector and solar operated pump for use with solar heating and cooling systems is discussed. The development hardware, problems encountered during fabrication and testing, and certification statements of performance are included.

  5. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  6. FEMAN: Fuzzy-Based Energy Management System for Green Houses Using Hybrid Grid Solar Power

    Directory of Open Access Journals (Sweden)

    Abdellah Chehri

    2013-01-01

    Full Text Available The United Nations has designated the year 2012 as the international year of sustainable energy. Today, we are seeing a rise in global awareness of energy consumption and environmental problems. Many nations have launched different programs to reduce the energy consumption in residential and commercial buildings to seek lower-carbon energy solutions. We are talking about the future green and smart houses. The subject of smart/green houses is not one of “why,” but rather “how,” specifically: “how making the future house more energy efficient.” The use of the renewable energy, the technology and the services could help us to answer this question. Intelligent home energy management is an approach to build centralized systems that deliver application functionality as services to end-consumer applications. The objective of this work is to develop a smart and robust controller for house energy consumption with maximizing the use of solar energy and reducing the impact on the power grid while satisfying the energy demand of house appliances. We proposed a fuzzy-based energy management controller in order to reduce the consumed energy of the building while respecting a fixed comfort.

  7. Test of a solar crop dryer

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard Jensen, S. [Teknologisk Institut. SolEnergiCentret, Taastrup (Denmark); Floejgaard Kristensen, E. [Danmarks JordbrugsForskning, Tjele (Denmark); Forman, T. [Aidt Miljoe A/S, Thorsoe (Denmark)

    2001-01-01

    One of the major goals of the project 'Test and Research Project into the Drying of Food and Wood Products with Solar Heat' was to develop and test a solar crop dryer for use in Ghana. Based on a survey in Ghana (Jensen, Frank and Kristensen, 1999) it was decided to develop a dryer for drying of maize for seed as the increase in value of the crop due the drying here would be high - the dryer may, however, also be used to dry other crops or other items - one unit will e.g. be erected in Ghana to test drying of fish. The capacity of the dryer was defined to be 500 kg having a collector area of approx 25 m{sup 2}. It was decided to let the dryer consist of 5 separate units each with a transparent collector area of 4.77 m{sup 2} and a capacity of approx. 100 kg. The modulized concept has several benfits: If one drying bed is operated improperly this will not affect the total quantity of crops being dried at that time. It is possible to dry different crops (creating different pressure drop) side by side without risking that the crop with the highest pressure drop will be dried improperly. Small dc fans are often cheaper than larger dc fans. The system will be less complex, and an even air distribution over the drying bed is easier obtainable. Finally it is possible to start with only one unit and then gradually increase the capacity of the solar dryer - this will make it easier to invest in a solar dryer. It was further decided that the fans of the dryer should be powered directly by PV-panels in order to make the dryer independent of an often unreliable, missing or expensive grid. The dryer is going to be erected and tested at Silwood Farms situated close to Accra. Silwood Farms has total land acreage of 210 acres where 176 acres are used for cultivating maize - the rest is used for gowing pineapple. A majority of the maize is processed into seed. The main harvest season for maize at Silwood Farms is August/September with a smaller harvest period in January

  8. Qualification test and analysis report: solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    Test results show that the Owens-Illinois Sunpak/sup TM/ Model SEC 601 air-cooled collector meets the national standards and codes as defined in the Subsystem Performance Specification and Verification Plan of NASA/MSFC Contract NAS8-32259, dated October 28, 1976. The architectural and engineering firm of Smith, Hinchman and Grylls, Detroit, Michigan, acted in the capacity of the independent certification agency. The program calls for the development, fabrication, qualification and delivery of an air-liquid solar collector for solar heating, combined heating and cooling, and/or hot water systems.

  9. Testing relativity with solar system dynamics

    Science.gov (United States)

    Hellings, R. W.

    1984-01-01

    A major breakthrough is described in the accuracy of Solar System dynamical tests of relativistic gravity. The breakthrough was achieved by factoring in ranging data from Viking Landers 1 and 2 from the surface of Mars. Other key data sources included optical transit circle observations, lunar laser ranging, planetary radar, and spacecraft (Mariner 9 to Mars and Mariner 10 to Mercury). The Solar System model which is used to fit the data and the process by which such fits are performed are explained and results are discussed. The results are fully consistent with the predictions of General Relativity.

  10. Water heating solar system for popular houses; Sistema solar de aquecimento de agua para residencias populares

    Energy Technology Data Exchange (ETDEWEB)

    Mogawer, Tamer; Souza, Teofilo Miguel de [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil). Centro de Energias Renovaveis], e-mail: teofilo@feg.unesp.br

    2004-07-01

    In this paper we present a case study for the design of a low cost solar heating system for a popular residence in an isolated rural community in the state of Rio Grande do Norte. This scaling can be extended to several rural communities that are in the same situation in Brazil as well as the wider use of solar power between the low-income people who do not have the benefits of electricity in their homes or want to have a lower cost of electricity. In this context, there are very interesting alternatives, among which is the replacement of electric heating bath water by heating by solar energy. According to several sources the electric shower, as it is now simple and extremely cheap, is the villain of the national electrical system. It is used in peak hours of consumption, something like 10% of electric generating capacity installed in Brazil, forcing many industries to switch off the machines because of the high cost of electricity during this period. Using the heating by solar energy, we can reduce consumption of electric shower and also increase the use of clean energy in popular homes and in isolated rural communities. This paper will address the use of solar energy with the basic purpose of heating water for bathing in popular residences and in isolated rural areas, using low cost systems, built with easily materials that is found in any area of the country. (author)

  11. A new insight into opaque envelopes in a passive solar house: Properties and roles

    International Nuclear Information System (INIS)

    Long, Linshuang; Ye, Hong; Liu, Minghou

    2016-01-01

    Highlights: • A new insight into the opaque envelopes of a passive solar house was gained. • Five parts of envelopes, i.e., roof, south/east/west/north walls, were discussed. • Each part of envelopes were analyzed separately rather than treated as a whole. • Ideal properties of materials for each envelope are diverse from one another. • Differences are related to the envelopes’ leading roles as a heater or a cooler. - Abstract: Passive solar houses are effective solutions for minimizing the operating energy of buildings. The building envelopes of passive solar houses exert a significant influence on the degree of indoor thermal comfort. The focus of this study was the construction of high-performance opaque envelopes, i.e., the roof and walls, for a passive solar house, and a new conception of the envelopes from the perspective of the relation between the properties and roles was provided. The discussion was conducted based on a comprehensive range of envelope materials that were distinguished by the thermal conductivity and volumetric heat capacity. For the first time, each part of the envelopes was analyzed separately rather than considered as an entire envelope. By analyzing each envelope individually, the optimum properties of each envelope were found to be distinct from each other. The distinctions are determined by the dominant role of each envelope, which is associated with the location and absorbed solar irradiation. For summer or hot climate applications, when the dominant role is a cooler, the envelope, e.g., the south wall, should consist of materials with high thermal conductivity and large heat capacity; if a heater is the dominant role, the envelope, e.g., the roof, should consist of materials with low thermal conductivity. For winter or cold climate applications, the envelopes with a leading role of a heater or a cooler require materials with high or low thermal conductivity, respectively. Under the guidance of the results, a discussion

  12. Accelerated stress testing of terrestrial solar cells

    Science.gov (United States)

    Lathrop, J. W.; Hawkins, D. C.; Prince, J. L.; Walker, H. A.

    1982-01-01

    The development of an accelerated test schedule for terrestrial solar cells is described. This schedule, based on anticipated failure modes deduced from a consideration of IC failure mechanisms, involves bias-temperature testing, humidity testing (including both 85-85 and pressure cooker stress), and thermal-cycle thermal-shock testing. Results are described for 12 different unencapsulated cell types. Both gradual electrical degradation and sudden catastrophic mechanical change were observed. These effects can be used to discriminate between cell types and technologies relative to their reliability attributes. Consideration is given to identifying laboratory failure modes which might lead to severe degradation in the field through second quadrant operation. Test results indicate that the ability of most cell types to withstand accelerated stress testing depends more on the manufacturer's design, processing, and worksmanship than on the particular metallization system. Preliminary tests comparing accelerated test results on encapsulated and unencapsulated cells are described.

  13. Testing the "Work Ability House" Model in hospital workers.

    Science.gov (United States)

    Martinez, Maria Carmen; Latorre, Maria do Rosário Dias de Oliveira; Fischer, Frida Marina

    2016-01-01

    To test the Work Ability House model, verifying the hierarchy of proposed dimensions, among a group of hospital workers. A cohort study (2009-2011) was conducted with a sample of 599 workers from a hospital in the city of São Paulo. A questionnaire including sociodemographics, lifestyle and working conditions was used. The Brazilian versions of Job Stress Scale, Effort-Reward Imbalance, Work-Related Activities That May Contribute To Job-Related Pain and/or Injury, and the Work Ability Index (WAI) were also used. A hierarchical logistic regression analysis was performed: the independent variables were allocated into levels according to the dimensions of the theoretical model in order to evaluate the factors associated with work ability. Variables associated with impairment of work ability in each dimension were as follows: (a) sociodemographics: age work injuries (p = 0.029), (c) professional competence: low educational level (p = 0.008), (d) values : intensified in overcommitment (p work: intensification of effort-reward imbalance (p = 0.009) and high demands (p = 0.040). The results confirmed the dimensions proposed for the Work Ability House model, indicating that it is valid as a representation of a multidimensional construct of multifactorial determination and can be used in the management of work ability.

  14. Application of Breathing Architectural Members to the Natural Ventilation of a Passive Solar House

    Directory of Open Access Journals (Sweden)

    Kyung-Soon Park

    2016-03-01

    Full Text Available The efficient operation of a passive solar house requires an efficient ventilation system to prevent the loss of energy and provide the required ventilation rates. This paper proposes the use of “breathing architectural members” (BAMs as passive natural ventilation devices to achieve much improved ventilation and insulation performance compared to mechanical ventilation. Considering the importance of evaluating the ventilation and insulation performances of the members, we also propose numerical models for predicting the heat and air movements afforded by the members. The numerical model was validated by comparison with experimental results. The effectiveness of the BAMs was also verified by installation in houses located in an area with warm climate. For this purpose, chamber experiments were performed using samples of the BAMs, as well as numerical simulations to assess natural ventilation and heat load. The main findings of the study are as follows: (1 the one-dimensional chamber experiments confirmed the validity of the numerical models for predicting the heat and air movements afforded by the BAMs. Comparison of the experimental and calculated values for the temperature of air that flowed into the room from outside revealed a difference of less than 5%; (2 observations of the case studies in which BAMs were installed in the ceilings and exterior walls of Tokyo model houses revealed good annual ventilation and energy-saving effects. When BAMs with an opening area per unit area of A = 0.002 m2/m2 were applied to three surfaces, the required ventilation rate was 0.5 ACH (air changes per hour, and this was achieved consistently. Compared to a house with general insulation and conventional mechanical ventilation, heating load was reduced by 15.3%–40.2% depending on the BAM installation points and the differing areas of the house models.

  15. Solar air-conditioning in buildings of houses; Climatizacion solar en edificios de viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Rey, F. J.; Velasco, E.; Flores, F.; Gonzalez, A. B.

    2008-07-01

    In this work we analyze the behavior of the components of a thermal solar energy captation system that provides support to a climatization system with low energy consumption composed by radiating-refreshing ground in a single family dwelling. The combination of both system allows to increase the efficiency of the climatization and to reduce the energy domestic consumption. These aspects are included in regional an national strategies of saving and efficiency energy. tho this end, we shall use the software TRNSYS 16 for the energy systems simulation. (Author)

  16. Long term performance of a solar floor and hot water heating house; Taiyonetsu yukadanbo kyuto jutaku no choki seino

    Energy Technology Data Exchange (ETDEWEB)

    Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Outlined herein are measured energy consumption followed for 12 years for a totally electrified solar house with a floor-heating and hot-water heating system. In the solar system, hot water generated by the solar collector is sent, via a surge tank, to a living room, dining room and study to heat their concrete floors, and recycled back to the collector after heating the heat-storage tank for hot water supply. The collector is of plate type, consisting of 6 units, each with a white glass sheet as the heat-collecting membrane for selectively absorbing heat. Its total heat-collecting area is 11.4m{sup 2}. Long-term performance of the solar system installed for floor and hot-water heating in a totally electrified solar house, is analyzed by the measured results collected for 12 years. The house consumes secondary energy of 11.7MWh/year on the average, which is approximately 20% lower that that required for a house of the equivalent size. The solar system has been operated smoothly, to supply 46 and 35% of the required heat for hot-water and floor heating. It is however estimated that annual heat loss reaches 34% in the hot-water heating system, including that in the electric hot-water generator, and prevention of heat loss is one of the major themes for the future system designs. 4 refs., 5 figs.

  17. 'Eco-house 99' - Full-scale demonstration of solar walls with building integrated heat storages

    Energy Technology Data Exchange (ETDEWEB)

    Hummelshoej, R.M.; Rahbek, J.E. [COWI Consulting Engineers and Planners AS (Denmark)

    2000-07-01

    A critical issue for solar systems in northern latitudes is the economic profitability. It is often said that the techniques for solar utilisation are expensive and unprofitable. This is, however, not always the case. A new project with 59 low energy terrace houses was carried out in Kolding, Denmark. The houses are designed as ecological buildings with emphasis on total economy based on low operation and maintenance costs, energy conservation and passive/hybrid solar utilisation. Besides direct solar gain through windows, each house has a solar wall of 6-8.5 m{sup 2} on the south facade. The solar walls are used both for heating of ventilation air and for space heating. The solar walls deliver heat to the dwellings during the heating season. To optimise the energy utilisation from the solar walls, the energy is stored internally in building integrated heat storages. Two different new types of prefabricated heat storages are built into the houses. One is an internal concrete wall with embedded ventilation pipes, and the other is a hollow concrete element with integrated stone bed. The heat storages are mainly designed to store solar energy from the day to the evening and the night. Because the solar walls and the heat storages have been a part of the design process from the start, the additional expenses are as low as 30-140 Euro/m{sup 2} solar wall compared with the alternative facade. This is far less than what it costs to add a solar wall on an existing building. Measurements over one year show that the yield of the solar walls is in the range of 115-125 kWh/m{sup 2}/year as expected. With the actual financing, the annual payment of the additional expenses for the solar systems is between 1-6 Euro/m{sup 2} solar wall, while the annual savings are about 5 Euro/year/m{sup 2} (with an energy price of 0.042 Euro/kWh). Dependent on which alternative facade construction the solar wall system is compared with, the profit of the system is in the range of 1 to +4 Euro

  18. [Clinical investigation of basophil activation test as a complementary test for house dust mite allergen].

    Science.gov (United States)

    Ren, H L; Li, J D; Miao, Y H; Xu, T

    2018-03-01

    Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  19. A Pedestrian Approach to Indoor Temperature Distribution Prediction of a Passive Solar Energy Efficient House

    Directory of Open Access Journals (Sweden)

    Golden Makaka

    2015-01-01

    Full Text Available With the increase in energy consumption by buildings in keeping the indoor environment within the comfort levels and the ever increase of energy price there is need to design buildings that require minimal energy to keep the indoor environment within the comfort levels. There is need to predict the indoor temperature during the design stage. In this paper a statistical indoor temperature prediction model was developed. A passive solar house was constructed; thermal behaviour was simulated using ECOTECT and DOE computer software. The thermal behaviour of the house was monitored for a year. The indoor temperature was observed to be in the comfort level for 85% of the total time monitored. The simulation results were compared with the measured results and those from the prediction model. The statistical prediction model was found to agree (95% with the measured results. Simulation results were observed to agree (96% with the statistical prediction model. Modeled indoor temperature was most sensitive to the outdoor temperatures variations. The daily mean peak ones were found to be more pronounced in summer (5% than in winter (4%. The developed model can be used to predict the instantaneous indoor temperature for a specific house design.

  20. Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing

    DEFF Research Database (Denmark)

    Helle, Tina

    and adapted according to accessibility norms and guidelines for housing design in Sweden, Denmark, Iceland and Finland. This iterative process involved occupational therapists, architects, building engineers and professional translators, resulting in the Nordic Housing Enabler. For reliability testing...... serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from the original Swedish version......, the sample strategy and data collection procedures were the same in all countries. In total, twenty voluntary occupational therapists collected data from 106 cases by means of the Nordic Housing Enabler. Inter-rater reliability was calculated by means of percentage agreement and kappa statistics. Overall...

  1. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  2. Performance Analysis of a Savonius Wind Turbine in the Solar Integrated Rotor House

    Directory of Open Access Journals (Sweden)

    ABDUL LATIFMANGANHAR

    2017-07-01

    Full Text Available Rooftop, building integrated and building augmented micro wind systems have the potential for small scale power generation in the built environment. Nevertheless, the expansion of micro wind technology is very slow and its market is strongly affected by the low efficiency of conventional wind generators. WAG-RH (Wind Accelerating and Guiding Rotor House which is a new technique introduced to enhance the efficiency of vertical axis rotor. The present study utilizes other green energy element by integrating the WAG-RH with a solar heating system. In this effort roof of the WAG-RH has been utilized to heat air through micro solar chimney for creating buoyancy effect in the air flow channel at rotor zone in the WAG-RH. The integration is capable of improving the performance of rotor setup in the WAG-RH as well as providing hot air with sufficient air mass flow rate for space heating. The WAG-RH had brought about 138% increase in the performance coefficient(Cp of conventional three bladed Savonius rotor, whereas solar integrated WAG-RH has contributed 162% increase in the Cp of the same rotor.

  3. Performance analysis of a savonius wind turbine in the solar integrated rotor house

    International Nuclear Information System (INIS)

    Manganhar, A.L.

    2017-01-01

    Rooftop, building integrated and building augmented micro wind systems have the potential for small scale power generation in the built environment. Nevertheless, the expansion of micro wind technology is very slow and its market is strongly affected by the low efficiency of conventional wind generators. WAG-RH (Wind Accelerating and Guiding Rotor House) which is a new technique introduced to enhance the efficiency of vertical axis rotor. The present study utilizes other green energy element by integrating the WAG-RH with a solar heating system. In this effort roof of the WAG-RH has been utilized to heat air through micro solar chimney for creating buoyancy effect in the air flow channel at rotor zone in the WAG-RH. The integration is capable of improving the performance of rotor setup in the WAG-RH as well as providing hot air with sufficient air mass flow rate for space heating. The WAG-RH had brought about 138% increase in the performance coefficient(Cp) of conventional three bladed Savonius rotor, whereas solar integrated WAG-RH has contributed 162% increase in the Cp of the same rotor. (author)

  4. Experimental Evaluation of Simple Thermal Storage Control Strategies in Low-Energy Solar Houses to Reduce Electricity Consumption during Grid On-Peak Periods

    Directory of Open Access Journals (Sweden)

    Kyoung-Ho Lee

    2015-08-01

    Full Text Available There is growing interest in zero-energy and low-energy buildings, which have a net energy consumption (on an annual basis of almost zero. Because they can generate both electricity and thermal energy through the use of solar photovoltaic (PV and solar thermal collectors, and with the help of reduced building thermal demand, low-energy buildings can not only make a significant contribution to energy conservation on an annual basis, but also reduce energy consumption and peak demand. This study focused on electricity consumption during the on-peak period in a low-energy residential solar building and considers the use of a building’s thermal mass and thermal storage to reduce electricity consumption in summer and winter by modulation of temperature setpoints for heat pump and indoor thermostats in summer and additional use of a solar heating loop in winter. Experiments were performed at a low-energy solar demonstration house that has solar collectors, hot water storage, a ground-coupled heat pump, and a thermal storage tank. It was assumed that the on-peak periods were from 2 pm to 5 pm on hot summer days and from 5 pm to 8 pm on cold winter days. To evaluate the potential for utilizing the building’s thermal storage capacity in space cooling and heating, the use of simple control strategies on three test days in summer and two test days in the early spring were compared in terms of net electricity consumption and peak demand, which also considered the electricity generation from solar PV modules on the roof of the house.

  5. Energy house - dream house

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    An energy house a prefabricated house with an extensive minimization of heat losses, is air-conditioned by means of a combined heating system consisting of hot water cycle and recirculating heating. The energy system is trivalent: wind power, solar energy with heat pumps and normal oil heating.

  6. Solar-System Tests of Gravitational Theories

    Science.gov (United States)

    Shapiro, Irwin

    1997-01-01

    We are engaged in testing gravitational theory by means of observations of objects in the solar system. These tests include an examination of the Principle Of Equivalence (POE), the Shapiro delay, the advances of planetary perihelia, the possibility of a secular variation G in the "gravitational constant" G, and the rate of the de Sitter (geodetic) precession of the Earth-Moon system. These results are consistent with our preliminary results focusing on the contribution of Lunar Laser Ranging (LLR), which were presented at the seventh Marcel Grossmann meeting on general relativity. The largest improvement over previous results comes in the uncertainty for (eta): a factor of five better than our previous value. This improvement reflects the increasing strength of the LLR data. A similar analysis presented at the same meeting by a group at the Jet Propulsion Laboratory gave a similar result for (eta). Our value for (beta) represents our first such result determined simultaneously with the solar quadrupole moment from the dynamical data set. These results are being prepared for publication. We have shown how positions determined from different planetary ephemerides can be compared and how the combination of VLBI and pulse timing information can yield a direct tie between planetary and radio frames. We have continued to include new data in our analysis as they became available. Finally, we have made improvement in our analysis software (PEP) and ported it to a network of modern workstations from its former home on a "mainframe" computer.

  7. A solar house self-sufficient of energy. Experiences on the way to energy autarky

    International Nuclear Information System (INIS)

    Voss, K.; Dohlen, K. v.; Lehmberg, H.; Stahl, W.; Wittwer, C.; Goetzberger, A.

    1994-01-01

    The solar house Freiburg which is self-sufficient of energy was completed in October 1992. After a long and complex planning phase now measuring and monitoring tasks as well as the realization fo improvement measures are to the fore. This article presents exemplary results of the first year of operation and compare them with the expectations. Self-sufficient operation of the building could be attained between April and October 1993. Here among others hydrogen was successfully produced by photovoltaic supplied electrolysis and was to a large degree used for thermal applications (cooking, heating). The fact that the supply of energy was not self-sufficient all the year round was due to the failure of the fuel cell used to produce electric power again with hydrogen. (orig./BWI) [de

  8. Evaluation of solar PV-projects of housing corporations; Evaluatie zon PV-projecten bij woningcorporaties

    Energy Technology Data Exchange (ETDEWEB)

    Kurstjens, M.J.H. [W/E Adviseurs, Utrecht (Netherlands)

    2013-09-15

    A study has been carried out to determine the failure and success factors with regard to the use of solar panels in the housing sector. Lessons learned from this evaluation form the basis for targeted communication and development of a guide for corporations. In the spring of 2013, stakeholders in eight representative initiatives in the Netherlands were interviewed. The failure and success factors are translated into recommendations to further develop tools for corporations [Dutch] Er is gezocht naar de faal- en succesfactoren rondom de toepassing van zonnepanelen in de woningbouwsector. Leerpunten uit deze evaluatie vormen de basis voor gerichte communicatie en ontwikkeling van (een) handreiking(en) voor corporaties. In het voorjaar van 2013 zijn betrokkenen bij acht representatieve initiatieven in Nederland geinterviewd. De faal- en succesfactoren zijn omgezet in aanbevelingen voor nader uit te werken hulpmiddelen voor corporaties.

  9. Performance evaluation of the Solar Building Test Facility

    Science.gov (United States)

    Jensen, R. N.

    1981-01-01

    The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

  10. Ademe et Vous. International Newsletter No. 30, September-October 2014. Solar Decathlon: Tomorrow's sustainable house

    International Nuclear Information System (INIS)

    Martin, Valerie; Seguin-Jacques, Catherine; Tappero, Denis

    2014-09-01

    A unique international university competition to design and build an energy autonomous, solar house: that was the brief for the Solar Decathlon held in France last July. Diversified and reliable, all forms of solar energy have a key role to play in the energy transition. ADEME has therefore opted actively to support the development of these technical solutions going forward. In December 2011, ADEME, ADEREE (Moroccan agency for the development of renewable energies and energy efficiency) and BMWi (German Federal Ministry of Economics and Technology) started up a twinning programme funded by the EU to encourage the development of energy efficiency and renewable energies in Morocco

  11. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  12. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  13. Testing for bubbles in housing markets: a panel data approach

    Czech Academy of Sciences Publication Activity Database

    Mikhed, V.; Zemčík, Petr

    2009-01-01

    Roč. 38, č. 4 (2009), s. 366-386 ISSN 0895-5638 R&D Projects: GA MŠk LC542 Institutional research plan: CEZ:AV0Z70850503 Keywords : house prices * cointegration * panel data Subject RIV: AH - Economics Impact factor: 0.659, year: 2009

  14. Foster Wheeler Solar Development Corporation modular industrial solar retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandoski, A.A.

    1986-10-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  15. Foster Wheeler Solar Development Corporation Modular Industrial Solar Retrofit qualification test results

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.; Lewandowski, A.A.

    1987-04-01

    Under the Department of Energy's Modular Industrial Solar Retrofit project, industrial process steam systems incorporating line-focus solar thermal collectors were designed and hardware was installed and tested. This report describes the test results for the system designed by Foster Wheeler Solar Development Corporation. The test series included function and safety tests to determine that the system operated as specified, an unattended operations test to demonstrate automatic operation, performance tests to provide a database for predicting system performance, and life cycle tests to evaluate component and maintenance requirements. Component-level modifications to improve system performance and reliability were also evaluated.

  16. Study on reduction of consumption and peak demand of electric power used in residential houses with solar heating and PV systems; Solar house no fuka heijunka to energy sakugen koka ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Udagawa, M.; Endo, T. [Kogakuin University, Tokyo (Japan)

    1994-12-08

    A model house was simulated to reduce the consumption and peak demand for the photovoltaic power generation system, and solar heat air heating and hot water supply system in the solar house. As a type of construction, both wooden construction and reinforced concrete (RC) construction were selected with a total floor area of 125m{sup 2}. All the rooms were equipped with an air conditioner by heat pump from the air thermal source. A solar heat floor heater was simultaneously installed on the first floor. The hot water supply load was 4.8MWh per year. A commercial grid-connected on-site system was applied to the photovoltaic power generation with a 20m{sup 2} wide monocrystalline Si solar cell panel. As for the fluctuation in power load, the peak at the time of rising is more reduced in the RC house than in the wooden house, because the former is smaller in temperature fluctuation than the latter during the intermittence of air conditioning (as per the specified operational schedule). Therefore, the power is more leveled off in the former than in the latter. Between both, difference was hardly made in energy consumption per year. The ratio of dependency was 47% upon the photovoltaic power generation system, while it was 50% and 77%, under the air heating power load and hot water supply power load, respectively, upon the solar heat air heating and hot water supply system, so that both systems were considerably effective in saving the energy. 5 refs., 7 figs., 1 tab.

  17. Breaking the cycle: Producer and consumer perspectives on the non-adoption of passive solar housing in the US

    International Nuclear Information System (INIS)

    Garrett, Vicki; Koontz, Tomas M.

    2008-01-01

    Creating the technologies to solve our energy and pollution problems is only one part of the solution. Getting the technologies adopted may be a larger hurdle. This study examines the adoption of a low- or no-cost technology, passive solar housing design, in the United States. Interviews with professionals involved in passive solar supply identified lack of demand as the most important factor, followed by availability, awareness, and economic incentives. Corresponding survey results from homebuyers in one region suggest that lack of demand represents not disinterest, but rather lack of availability when purchasing a home. Conventional homeowners are not familiar with passive solar design, but are predisposed to favor it, especially if it can be incorporated into traditional housing styles. In addition, to the extent that they can learn information to counter the perceptions that passive solar homes are too complicated or there is too little sun in their region, homebuyers would be more willing to purchase a passive solar home. Policy interventions to promote passive solar homes should focus on supply-side incentives as well as information for homebuyers

  18. Breaking the cycle: Producer and consumer perspectives on the non-adoption of passive solar housing in the US

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, Vicki; Koontz, Tomas M. [School of Environment and Natural Resources, The Ohio State University, 210 Kottman Hall, 2021 Coffey Road, Columbus, OH 43210 (United States)

    2008-04-15

    Creating the technologies to solve our energy and pollution problems is only one part of the solution. Getting the technologies adopted may be a larger hurdle. This study examines the adoption of a low- or no-cost technology, passive solar housing design, in the United States. Interviews with professionals involved in passive solar supply identified lack of demand as the most important factor, followed by availability, awareness, and economic incentives. Corresponding survey results from homebuyers in one region suggest that lack of demand represents not disinterest, but rather lack of availability when purchasing a home. Conventional homeowners are not familiar with passive solar design, but are predisposed to favor it, especially if it can be incorporated into traditional housing styles. In addition, to the extent that they can learn information to counter the perceptions that passive solar homes are too complicated or there is too little sun in their region, homebuyers would be more willing to purchase a passive solar home. Policy interventions to promote passive solar homes should focus on supply-side incentives as well as information for homebuyers. (author)

  19. Photovoltaic Test and Demonstration Project. [for solar cell power systems

    Science.gov (United States)

    Forestieri, A. F.; Brandhorst, H. W., Jr.; Deyo, J. N.

    1976-01-01

    The Photovoltaic Test and Demonstration Project was initiated by NASA in June, 1975, to develop economically feasible photovoltaic power systems suitable for a variety of terrestrial applications. Objectives include the determination of operating characteristic and lifetimes of a variety of solar cell systems and components and development of methodology and techniques for accurate measurements of solar cell and array performance and diagnostic measurements for solar power systems. Initial work will be concerned with residential applications, with testing of the first prototype system scheduled for June, 1976. An outdoor 10 kW array for testing solar power systems is under construction.

  20. U.S. Department of Energy Solar Decathlon: Challenging Students to Build Energy Efficient, Cost-Effective, and Attractive Solar-Powered Houses

    Energy Technology Data Exchange (ETDEWEB)

    Simon, J.

    2012-01-01

    The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The winner of the competition is the team that best blends affordability, consumer appeal, and design excellence with optimal energy production and maximum efficiency. The paper discusses the solutions developed for the event. We believe that the solutions implemented for Solar Decathlon 2011 represent current trends and that by analyzing, critiquing, and exposing the solutions pursued, the industry can become better suited to address challenges of the future. Constructing a solar community using high-efficiency design and unique materials while remaining code compliant, safe, and effective results in solutions that are market relevant, important, and interesting to the industry as a whole.

  1. ANALYSIS AND THINKING OF ACTIVE SOLAR HEATING HOUSE%太阳能主动式采暖实测与分析

    Institute of Scientific and Technical Information of China (English)

    李元哲; 单明; 何端练

    2009-01-01

    通过对一栋位于北京昌平地区的主动式太阳房的全冬季测试数据进行分析,得到了太阳能保证率及其若干重要影响因素,并给出了其辅助热源的合理设计和运行方式.%It has provided widest application prospect for more and more attentions are paid to energy saving and discharge reduction all over the world. As an important aspect of solar energy utilization of low temperature, active solar energy heating is involved in many factors, which can influence the running effect and economy of the whole system dramatical-ly. Detailed testing data about an active solar house in Beijing Changping district has been analyzed in this paper. Solar fraction and its several influencing factors were discussed. Based on the results, the reasonable design method and opera-tion way has been established when an air-source heat pump was acted as auxiliary source of solar energy.

  2. Evaluation of load rejection to house load test at 50% power for UCN 3

    International Nuclear Information System (INIS)

    Lee, Chang Gyun; Sohn, Suk Whun; Sohn, Jong Joo; Seo, Jong Tae; Lee, Sang Keun; Kim, Yong Sung; Nam, Kyu Won; Jung, Yang Mook; Chae, Kyeong Sik; Koh, Bum Jae; Oh, Chul Sung; Park, Hee Chool

    1998-01-01

    The Load Rejection to House Load test at 50% power was successfully performed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3 and 4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as completeness of the plant design

  3. Design and testing of an innovative solar radiation measurement device

    International Nuclear Information System (INIS)

    Badran, Omar; Al-Salaymeh, Ahmed; El-Tous, Yousif; Abdala, Wasfi

    2010-01-01

    After review of studies conducted on the solar radiation measuring systems, a new innovative instrument that would help in measuring the accurate solar radiation on horizontal surfaces has been designed and tested. An advanced instrument with ease of use and high precision that would enable the user to take the readings in terms of solar intensity (W/m 2 ) has been tested. Also, the innovative instrument can record instantaneous readings of the solar intensities as well as the averages value of the solar radiation flux during certain periods of time. The instrument based in its design on being programmed by programmable interfacing controller (PIC). Furthermore, the power supply circuit is fed by the solar energy cells and does not need an external power source.

  4. Solar neutrinos: proposal for a new test

    International Nuclear Information System (INIS)

    Freedman, M.S.; Stevens, C.M.; Horivitz, E.P.; Fuchs, L.H.; Lerner, J.L.; Goodman, L.S.; Childs, W.J.; Hessler, J.

    1976-01-01

    The predicted flux on the earth of solar neutrinos has eluded detection, confounding current ideas of solar energy production by nuclear fusion. The dominant low-energy component of that flux can be detected by mass-spectrometric assay of the induced tiny concentration of 1.6 x 10 7 year lead-205 in old thallium minerals. Comments are solicited from those in all relevant disciplines

  5. On the Testing of Renovations Inside Historical Opera Houses

    Science.gov (United States)

    Fausti, P.; Prodi, N.

    2002-11-01

    Due to the large number of historical opera houses in Italy, many theatres have been renovated in the past, but still more will undergo major restoration in the near future. Unfortunately in this context, the quality and protection of acoustics is rarely considered as an issue of its own. As a consequence, the renovations are hardly ever accompanied by proper scientific and technical support. In this paper, the acoustical impact of works inside the Teatro Municipale "R.Valli" in Reggio Emilia, including the restoration of the main hall and the construction of a new acoustic shell, will be dealt with. Surveys were held in the theatre before renovation and were repeated with identical procedure and instruments after its completion. By means of a comparative analysis of the architectural project and of acoustical data, the impact of major changes in the theatre can be predicted. It is shown that this approach can help in drafting an operational scheme for safeguarding the acoustics of historical opera houses.

  6. Energy-active walls for solar houses made by using energy accumulating panels with ecologically safe panels

    International Nuclear Information System (INIS)

    Alexandrov, Y.

    2006-01-01

    The paper presents the opportunities for separate assemblage and dismounting of the structural layers of energy-accumulating panels, meant for construction of energy-active walls, which could find an application in the process of building of so called 'solar houses'. A situation has been considered, for a panel, whose structure layers after the expiration of their operational term could be dismounted separately and could be recycled for secondary use

  7. A pilot solar water disinfecting system: performance analysis and testing

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, T.S.; El-Ghetany, H.H. [Tohoku University, Sendai (Japan). Dept. of Aeronautics and Space Engineering

    2002-07-01

    In most countries, contaminated water is the major cause of most water-borne diseases. Disinfection of water may be accomplished by a number of different physical-chemical treatments including direct application of thermal energy, chemical and filtration techniques. Solar energy also can be used effectively in this field because inactivation of microorganisms is done either by heating water to a disinfecting temperature or by exposing it to ultraviolet solar radiation. A pilot solar system for disinfecting contaminated water is designed, constructed and tested. Investigations are carried out to evaluate the performance of a wooden hot box solar facility as a solar disinfectant. Experimental data show that solar energy is viable for the disinfection process. A solar radiation model is presented and compared with the experimental data. A mathematical model of the solar disinfectant is also presented. The governing equations are solved numerically via the fourth-order Runge-Kutta method. The effects of environmental conditions (ambient temperature, wind speed, solar radiation, etc.) on the performance of the solar disinfectant are examined. Results showed that the system is affected by ambient temperature, wind speed, ultraviolet solar radiation intensity, the turbidity of the water, the quantity of water exposed, the contact area between the transparent water container in the solar disinfectant and the absorber plate as well as the geometrical parameters of the system. It is pointed out that for partially cloudy conditions with a low ambient temperature and high wind speeds, the thermal efficiency of the solar disinfectant is at a minimum. The use of solar energy for the disinfection process will increase the productivity of the system while completely eliminating the coliform group bacteria at the same time. (author)

  8. Unlocking Solar for Low- and Moderate-Income Residents: A Matrix of Financing Options by Resident, Provider, and Housing Type

    Energy Technology Data Exchange (ETDEWEB)

    Cook, Jeffrey J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bird, Lori A. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2018-01-02

    Historically the low and moderate income (LMI) market has been underserved by solar photovoltaics (PV), in part due to the unique barriers LMI residents face to participation in the PV market. The intent of this report is to identify the most promising strategies state policymakers might consider to finance PV for LMI customers across three housing types: single family, multi-family, and manufactured housing. The result is a financing matrix that documents the first and second tier financing options states may consider for each housing type. The first tier options were selected based upon their potential impact on LMI PV deployment. Second tier financing approaches could also be used to achieve state policy goals, but may not have as much effect on the relevant LMI market segment. Nevertheless, each financing option comes with tradeoffs that state policymakers may wish to consider when they make decisions about which financing approaches are best suited to achieve their LMI PV deployment goals.

  9. New design algorithm and reliability testing of solar powered near ...

    African Journals Online (AJOL)

    New design algorithm and reliability testing of solar powered near-space flight vehicle for defense and security. ... To overcome this problem, we propose a pseudo-satellite system where telecommunication devices are carried on a perpetually flying solar aircraft cruising at stratospheric altitude. Our aircraft will combine ...

  10. Prospects for jointly using solar and wind energy for heat supply and hot water supply to private houses under the conditions of Baku

    International Nuclear Information System (INIS)

    Salamov, O. M.; Aliev, F. F.

    2013-01-01

    This paper analyzes the discovery of the potential for jointly using solar and wind energy for heat supply (HS) and hot water supply (HWS) to a one-family private house located in the Apsheron Peninsula. (authors)

  11. Optimization Schedule of Solar Energy House%太阳能小屋的最优设计

    Institute of Scientific and Technical Information of China (English)

    赵国喜; 代林帅

    2013-01-01

    研究了太阳能发电装置的电池组件选配问题,建立了双目标规划模型,并进行了求解。有效地设计出太阳能光伏电池板最优铺设方案,并给出了光伏电池逆转换器配置办法,提出了一种比较经济的太阳能小屋设计办法。%Double objective programming mode is established and solved based on battery component matching problem with solar energy generation device. The optimal laying scenario for solar photovoltaic panels is designed effectively, and configuration method of photovoltaic battery inverse converter is given. An economical solar house design is proposed.

  12. Environmental simulation testing of solar cell contamination by hydrazine

    Science.gov (United States)

    Moore, W. W., Jr.

    1972-01-01

    Test results for thermal vacuum and radiation environment simulation of hydrazine contamination are discussed. Solar cell performance degradation, measured by short circuit current, is presented in correlation with the variations used in environmental parameters.

  13. Evaluation of performance for solar house with Trombe wall. Part 5; Trombe hekishiki solar house no hyoka kenkyu (nichisekisan Trombe heki kyuhonetsuryo yosoku senzu no teian)

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, N [Nishimatsu Construction Co. Ltd., Kanagawa (Japan); Nakajima, Y [Kogakuin University, Tokyo (Japan); Watanabe, T [Tokyo Electric Power Service Co. Ltd., Tokyo (Japan); Abe, H [Ministry of Construction, Tokyo (Japan); Yamaga, K [Mitsubishi Estate Co. Ltd., Tokyo (Japan)

    1996-10-27

    A regression equation that can calculate the daily accumulated absorption heat of Trombe Wall was given, and the performance estimated chart of Trombe Wall in which the daily unit effect of Trombe Wall can be visually recognized was proposed. The absorption heat was multivariate-analyzed by two variables of solar radiation of that day and the previous day. The data obtained from simulation was used for analysis. The absorption heat was analyzed using the meteorological data at eight spots (Sapporo, Sendai, Niigata, Tokyo, Shizuoka, Kochi, Fukushima, and Kagoshima). In this case, the result of multivariate analysis almost coincided with the simulation result. A chart that predicts the absorption heat of Trombe Wall in eight cities from the daily accumulated global solar radiation of that day and the previous day was then created as the performance estimated chart of Trombe Wall. As a result, the solar radiation of that day little influences the absorption heat when the Trombe Wall increases in thickness. Conversely, the solar radiation of the previous day significantly influences the absorption heat. In future, an equivalent heat loss coefficient will be calculated from the performance estimated chart. 2 refs., 16 figs., 2 tabs.

  14. An evaluation of the installation of solar photovoltaic in residential houses in Malaysia: Past, present, and future

    International Nuclear Information System (INIS)

    Muhammad-Sukki, Firdaus; Ramirez-Iniguez, Roberto; Abu-Bakar, Siti Hawa; McMeekin, Scott G.; Stewart, Brian G.

    2011-01-01

    This paper examines solar energy development in Malaysia, particularly in relation to the installation of solar Photovoltaic (PV) in residential houses. It analyzes the past activities related to solar energy in Malaysia, in terms of research and developments (R and Ds), the implementations used as well as the national policies for the past 20 years which have pushed the installation of PV in the country. The Feed-In Tariff (FiT) scheme is discussed, showing comparative cost-benefit analysis between the PV installation in houses in the United Kingdom (UK) and Malaysia, and with other investment schemes available in Malaysia. To investigate the awareness of renewable energy policies and incentives, a preliminary survey of the public opinion in Malaysia has been carried out, and an evaluation of public willingness to invest in the FiT scheme by installing the PV on their houses is presented. The cost-benefit analysis shows that the proposed FiT programme is capable of generating good return on investment as compared to the one in the UK, but the return is lower than other investment tools. The survey suggests that most Malaysians are unaware of the government’s incentives and policies towards renewable energies, and are not willing to invest in the FiT scheme. - Highlights: ► Past activities related to solar energy is evaluated and FIT scheme is discussed. ► Financial analysis is presented; public perspective is evaluated. ► The FIT scheme generates higher return for PV installation in Malaysia than in the UK. ► The scheme, however, produces lower return than most investment schemes. ► Malaysians’ awareness levels are low and are not willing to invest in the FIT scheme.

  15. Verification of the Performance of a Vertical Ground Heat Exchanger Applied to a Test House in Melbourne, Australia

    Directory of Open Access Journals (Sweden)

    Koon Beng Ooi

    2017-10-01

    Full Text Available The ground heat exchanger is traditionally used as a heat source or sink for the heat pump that raises the temperature of water to about 50 °C to heat houses. However, in winter, the heating thermostat (temperature at which heating begins in the Australian Nationwide House Energy Rating Scheme (NatHERS is only 20 °C during daytime and 15 °C at night. In South-East Melbourne, the temperature at the bottom of a 50-meter-deep borehole has been recorded with an Emerson™ recorder at 17 °C. Melbourne has an annual average temperature of 15 °C, so the ground temperature increases by 2 °C per 50-m depth. A linear projection gives 23 °C at 200-m of depth, and as the average undisturbed temperature of the ground for a 400-m-deep vertical ground heat exchanger (VGHE. This study, by simulation and experimentation, aims to verify that the circulation of water in the VGHE’s U-tube to low-temperature radiators (LTRs could heat a house to thermal comfort. A literature review is included in the introduction. A simulation, using a model of a 60-m2 experimental house, shows that the daytime circulation of water in this VGHE/LTR-on-opposite-walls system during the 8-month cold half of the year, heats the indoors to NatHERS settings. Simulation for the cold half shows that this VGHE-LTR system could cool the indoors. Instead, a fan creating a cooling sensation of up to 4 °C is used so that the VGHE is available for the regeneration of heat extracted from the ground during the cold portion. Simulations for this hot portion show that a 3.4-m2 flat plate solar collector can collect more than twice the heat extracted from the ground in the cold portion. Thus, it can thus replenish the ground heat extracted for houses double the size of this 60-m2 experimental house. Therefore, ground heat is sustainable for family-size homes. Since no heat pump is used, the cost of VGHE-LTR systems could be comparable to systems using the ground source heat pump. Water

  16. Testing of modular industrial solar retrofit industrial process steam systems

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, C.P.; Dudley, V.E.

    1984-06-13

    Under the Department of Energy's Modular Industrial Solar Retrofit project, five industrial process heat systems incorporating line-focus solar collectors were designed and hardware was installed and tested at Sandia National Laboratories and the Solar Energy Research Institute. System designers and collector manufacturers participating in the project included Acurex Solar Corporation, BDM, Inc., Custom Engineering, Inc., Foster Wheeler Solar Development Corporation, Solar Kinetics, Inc., and Suntec Systems, Inc. This paper describes the testing of the qualification test systems which has been under way since mid-1982. Each qualification test system includes an equipment skid sufficient to support a collector field of 2300 m/sup 2/ aperture and one delta-tempeature string of from 175 to 460 m/sup 2/ aperture. Each system is capable of producing saturated steam at 1.7 MPa and operates at maximum outlet temperatures of from 250 to 290/sup 0/C. The test series includes function and safety tests to determine that the systems operate as specified, an unattended operation test of at least two weeks duration, performance tests to allow prediction of annual system performance, and life cycle tests to evaluate component lifetime and maintenance requirements. Since the start of testing, some twenty five modifications have been made to the various systems for the purpose of improving system performance and/or reliability, and appropriate tests of these modifictions have been made or are underway. This paper presents a description of the approach to testing of the MISR systems and selected test results.

  17. A Practical Guide To Solar Array Simulation And PCDU Test

    Science.gov (United States)

    Schmitz, Noah; Carroll, Greg; Clegg, Russell

    2011-10-01

    Solar arrays consisting of multiple photovoltaic segments provide power to satellites and charge internal batteries for use during eclipse. Solar arrays have unique I-V characteristics and output power which vary with environmental and operational conditions such as temperature, irradiance, spin, and eclipse. Therefore, specialty power solutions are needed to properly test the satellite on the ground, especially the Power Control and Distribution Unit (PCDU) and the Array Power Regulator (APR.) This paper explores some practical and theoretical considerations that should be taken into account when choosing a commercial, off-the-shelf solar array simulator (SAS) for verification of the satellite PCDU. An SAS is a unique power supply with I-V output characteristics that emulate the solar arrays used to power a satellite. It is important to think about the strengths and the limitations of this emulation capability, how closely the SAS approximates a real solar panel, and how best to design a system using SAS as components.

  18. Testing for Dark Matter Trapped in the Solar System

    Science.gov (United States)

    Krisher, Timothy P.

    1996-01-01

    We consider the possibility of dark matter trapped in the solar system in bound solar orbits. If there exist mechanisms for dissipating excess kinetic energy by an amount sufficient for generating bound solar orbits, then trapping of galactic dark matter might have taken place during formation of the solar system, or could be an ongoing process. Possible locations for acumulation of trapped dark matter are orbital resonances with the planets or regions in the outer solar system. It is posible to test for the presence of unseen matter by detecting its gravitational effects. Current results for dynamical limits obtained from analyses of planetary ephemeris data and spacecraft tracking data are presented. Possible future improvements are discussed.

  19. PSA Solar furnace: A facility for testing PV cells under concentrated solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Reche, J.; Canadas, I.; Sanchez, M.; Ballestrin, J.; Yebra, L.; Monterreal, R.; Rodriguez, J.; Garcia, G. [Concentration Solar Technologies, Plataforma Solar de Almeria-CIEMAT P.O. Box 22, Tabernas, E-04200 (Almeria) (Spain); Alonso, M.; Chenlo, F. [Photovoltaic Components and Systems, Renewable Energies Department-CIEMAT Avda. Complutense, 22, Madrid, E-28040 (Spain)

    2006-09-22

    The Plataforma Solar de Almeria (PSA), the largest centre for research, development and testing of concentration solar thermal technologies in Europe, has started to apply its knowledge, facilities and resources to development of the Concentration PV technology in an EU-funded project HiConPV. A facility for testing PV cells under solar radiation concentrated up to 2000x has recently been completed. The advantages of this facility are that, since it is illuminated by solar radiation, it is possible to obtain the appropriate cell spectral response directly, and the flash tests can be combined with prolonged PV-cell irradiation on large surfaces (up to 150cm{sup 2}), so the thermal response of the PV cell can be evaluated simultaneously. (author)

  20. Evaluation of Load Rejection to house load test at 50% power for UCN 3

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Gyun; Sohn, Suk Whun; Sohn, Jong Joo; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Yong Sung; Nam, Kyu Won; Jung, Yang Mook; Chae, Kyeong Sik; Koh, Bum Jae; Oh, Chul Sung; Park, Hee Chool [Korea Electric Power Corporation, Taejon (Korea, Republic of)

    1999-12-31

    The Load Rejection to House Load test at 50% power was successfully performed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3 and 4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design. 3 refs., 8 figs., 1 tab. (Author)

  1. Evaluation of Load Rejection to house load test at 50% power for UCN 3

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Gyun; Sohn, Suk Whun; Sohn, Jong Joo; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Kim, Yong Sung; Nam, Kyu Won; Jung, Yang Mook; Chae, Kyeong Sik; Koh, Bum Jae; Oh, Chul Sung; Park, Hee Chool [Korea Electric Power Corporation, Taejon (Korea, Republic of)

    1998-12-31

    The Load Rejection to House Load test at 50% power was successfully performed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3 and 4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design. 3 refs., 8 figs., 1 tab. (Author)

  2. The seed of change in society. Diffusion of solar cell systems in housing by means of pilot projects

    International Nuclear Information System (INIS)

    Van Mierlo, B.C.

    2002-01-01

    The central question in this thesis is: in what way can pilot projects contribute to the diffusion of new sustainable technologies, in particular solar cell systems in housing units. The reason for this is, in the first place, that trials, demonstration projects, practical experiments and market introduction projects are often launched by firms and subsidised by the state. The objective of such projects, referred to here as pilot projects, is in general to prepare the market introduction of new technologies. However, these projects are often realised and financed without much information being available on how they operate: about how they could prepare the market launch and how this function could be optimised. The second reason is that since the end of the 1980s the expectations in the Netherlands in respect of solar cell systems (PV systems) connected to the electricity grid have been high. These systems could have great advantages for the environment and after 2010 could be the most important source of sustainable energy. The government sees housing as the most promising market segment for these systems. It is recognised that certain major bottlenecks have to be solved before a large-scale diffusion is possible. According to the niche approach, the basic starting point of this thesis, this means that the existing social-technological regime needs to change: the rules and infrastructure according to which the existing technologies are, as it were, considered self-evident, and which hinder the introduction of new technologies. Subsidised pilot projects form a protected market niche that can stimulate a change in the regime by learning and by the social embedding of the learning experiences. According to this approach, a protected market niche is a necessary component of state-supported innovation policy if market niches do not arise spontaneously. It is, however, a limited instrument since the ultimate impact on existing regimes depends mainly on external factors

  3. A self-calibrating led-based solar test platform

    DEFF Research Database (Denmark)

    Krebs, Frederik C; Sylvester-Hvid, Kristian O.; Jørgensen, Mikkel

    2011-01-01

    A compact platform for testing solar cells is presented. The light source comprises a multi-wavelength high-power LED (light emitting diode) array allowing the homogenous illumination of small laboratory solar cell devices (substrate size 50 × 25 mm) within the 390–940 nm wavelength range......, it is possible to perform all the commonly employed measurements on the solar cell at very high speed without moving the sample. In particular, the LED-based illumination system provides an alternative to light-biased incident photon-to-current efficiency measurement to be performed which we demonstrate. Both...

  4. Solar heating system with seasonal storage for the 'Heumatt' housing development in Zurich; Solare Waermeversorgung mit saisonalem Speicher fuer die Wohnsiedlung Heumatt, Zuerich Seebach

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, P.; Juzi, H.

    2003-07-01

    This final report for the Swiss Federal Office of Energy describes a project proposal for the seasonal storage of heat produced by solar collectors to provide a fifty-percent coverage of the space heating and hot water demands of a housing scheme with 140 dwellings in Zurich, Switzerland. The report describes the project, including the collection of solar energy and the storage of heat in an underground storage area. Figures are given on the estimates of energy requirements and energy production. The investments needed for the realisation of the project are quoted. The report also includes a detailed report on the concept and reviews of the project made by the University of Applied Technology in Winterthur and that of Southern Switzerland.

  5. A procedure for analysing energy savings in multiple small solar water heaters installed in low-income housing in Brazil

    International Nuclear Information System (INIS)

    Giglio, Thalita; Lamberts, Roberto; Barbosa, Miriam; Urbano, Mariana

    2014-01-01

    Due to government subsidies, Brazil has witnessed an increase in the installation and use of small solar water heating systems in low-income housing projects. Although the initiative has reduced the load curve during peak times due to the reduced use of electric showerheads, measurement and verification (M and V) are needed to validate the savings. M and V procedures should take into account the social and economic variability of low-income housing developments. To improve M and V in low-income housing projects, this paper presents a methodology for identifying homogeneous subgroups based on their energy-saving potential. This research strategy involved a cluster analysis designed to improve the understanding of what energy savers and other influencing factors exist. A case study in Londrina Brazil was undertaken with 200 low-income families. Five clusters, created based on savings potential, were defined. The results showed that only two clusters demonstrated good electricity savings, representing 47% of families. However, two clusters, or 37%, did not provide satisfactory savings, and the other 16% did not provide any consumption history due to previous use of illegal city electricity connection practices. Therefore, studies confirm the need for a detailed measurement of the representative subgroups to assess the influence of human behaviour on potential SWHS-induced savings. - Highlights: • M and V is necessary to improve solar collector-area-based subsidy programmes. • M and V in large-scale sample should contemplate the social and economic variability. • Samples with homogeneous subgroups contribute to a consistent energy-saving M and V. • Solar Water Heaters in some cases may not offer energy saving in a low-income context. • SWH performance decreases with low educational level and difficulty of operation

  6. Experimental characterization. Thermal and solar performance of houses built; Caracterizacion experimental. comportamiento termico y solar de viviendas construidas

    Energy Technology Data Exchange (ETDEWEB)

    Carrilo, A.; Jurado, L.; Molina, J. C.; Druet, L.

    2011-07-01

    In this communication we describe the calibration of a simulation model of a house. is the Energy Plus simulation program, and the experimental procedure is based on the method PSTAR (Subbarao, 1988) which are obtained adjustment factors that provide a quantitative interpretation of the discrepancies. (Author)

  7. Effects of Metabolic Cage Housing on Rat Behavior and Performance in the Social Interaction Test.

    Science.gov (United States)

    Whittaker, Alexandra L; Lymn, Kerry A; Howarth, Gordon S

    2016-01-01

    Although the metabolic cage is commonly used for housing nonhuman animals in the laboratory, it has been recognized as constituting a unique stressor. Such an environment would be expected to affect behavioral change in animals housed therein. However, few studies have specifically addressed the nature or magnitude of this change. The current study sought to characterize the behavioral time budget of rats in metabolic cage housing in comparison to that of individually housed animals in standard open-top cages. Rats in metabolic cages spent less time moving, manipulating enrichment, and carrying out rearing behaviors, and there was a corresponding shift toward inactivity. In an applied Social Interaction Test, behavioral scoring implied that metabolic cage housing had an anxiogenic effect. In conclusion, metabolic cage housing produces measurable effects on spontaneous and evoked behavior in rats in the laboratory. These behavioral changes may lead to a negative emotional state in these animals, which could have negative welfare consequences. Further research is needed to quantify the existence and magnitude of such an effect on rat well being.

  8. Autonomous houses. Autonomous house

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, S. (Tokai University, Tokyo (Japan). Faculty of Engineering)

    1991-09-30

    Self-sufficiency type houses are outlined. On condition that people gain a certain amount of income in relation with the society, they self-suffice under the given environment, allowing themselves to accept a minimum of industrial products with small environmental load. Ordinary supply from outside of fossil energy and materials which depend on it is minimized. Types are classified into three: energy, energy materials and perfect self-sufficiency. A study project for environment symbiotic houses is progressing which is planned by the Ministry of Construction and Institute of Building Energy Conservation and is invested by a private company. Its target is making a house for halving an environmental load by CO{sub 2}, for the purpose of creating the environment symbiotic house which is nice to and in harmony with the global environment and human beings. As a part of the studies on energy-saving and resource conservation on houses, introduced is a plan of an autonomous house at Izu-Atagawa. The passive method and high thermal-insulation are used for air conditioning, and hot spring water for hot water supply. Electric power is generated by hydroelectric power generation using mountain streams and by solar cells. Staple food is purchased, while subsidiary food is sufficed. 17 refs., 4 figs., 1 tab.

  9. Development and performance test of a solar tracker

    Energy Technology Data Exchange (ETDEWEB)

    Mahdi, T.H.; Hasib, Z.M. [Bangladesh Univ. of Engineering and Technology, Dhaka (Bangladesh). Dept. of Mechanical Engineering

    2010-07-01

    This paper discussed the development of a low-cost solar tracker device designed for use in developing countries. Expert control sensors and input-output interfaces were integrated with a tracking mechanism to increase the energy generation efficiency of the solar panel. Light sensing devices were used to automatically track the sun's rays. The controller sensors were integrated with the tracking mechanism. The control system was implemented on a microcontroller-based embedded system. A graphical user interface (GUI) was incorporated with a commercial software program in order to make the system more user-friendly. Performance tests demonstrated that the tracking system increases the amount of power that the solar panels could obtain. The efficiency of the panels increased by between 18 and 23 percent. Operators were able to control the movement of individual solar panels from a control room. The system also alerted operators of environmental damage to the panels. 12 refs., 2 tabs., 13 figs.

  10. Comparison of DOE-2 with measurements in the Pala Test houses

    Energy Technology Data Exchange (ETDEWEB)

    Meldem, R.; Winkelmann, F.

    1995-07-01

    The predictions of the DOE-2 program for building energy analysis have been compared with measurements in the Pala test houses near San Diego. This work is part of the California Institute for Energy Efficiency {open_quotes}Alternatives to Compressor Cooling in California Transition Zones{close_quotes} project in which DOE-2 is being used for parametric analysis of cooling strategies that reduce peak electrical power in hot, dry climates. To establish the validity of DOE-2 for this kind of analysis the program was compared with room air temperature measurements in a {open_quotes}low-mass{close_quotes} house with conventional insulated study wall construction and a {open_quotes}high-mass{close_quotes} house with insulated concrete walls. To test different aspects of the DOE-2 calculation, four different unconditioned thermal configurations of these houses were considered: unshaded windows, shaded windows, white exterior surfaces, and forced night ventilation. In all cases DOE-2 agreed well with the air temperature measurements, with a mean deviation between simulation and measurement ranging from 0.2 to 1.0 K depending on configuration and type of house. Using a development version of DOE-2 comparisons with inside surface temperature measurements were also made. These comparisons also showed good agreement.

  11. Testing space weather connections in the solar system

    Science.gov (United States)

    Grison, B.; Souček, J.; Krupař, V.; Píša, D.; Santolík, O.; Taubenschuss, U.; Němec, F.

    2017-09-01

    This study aims at testing and validating tools for prediction of the impact of solar events in the vicinity of inner and outer solar system planets using in-situ spacecraft data (primarily MESSENGER, STEREO and ACE, but also VEX and Cassini), remote Jovian observations (Hubble telescope, Nançay decametric array), existing catalogues (HELCATS and Tao et al. (2005)) and the tested propagating models (the ICME radial propagation tool of the CDPP and the 1-D MHD code propagation model presented in Tao et al. (2005)).

  12. Image dissector photocathode solar damage test program. [solar radiation shielding using a fast optical lens

    Science.gov (United States)

    Smith, R. A.

    1977-01-01

    Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

  13. Behavioral profiles of genetically selected aggressive and nonaggressive male wild house mice in two anxiety tests

    NARCIS (Netherlands)

    Hogg, S; Wurbel, H; Steimer, T; de Ruiter, A; Koolhaas, J; Sluyter, F; Driscoll, Peter

    2000-01-01

    Artificially selected aggressive (SAL) and non-aggressive (LAL) male house mice were tested in a hexagonal tunnel maze and light-dark preference (LD) box to determine if the bidirectional selection for aggressive behavior leads to a coselection for different levels of trait anxiety. The tunnel maze

  14. Design, Construction and Testing of Simple Solar Maize Dryer

    Directory of Open Access Journals (Sweden)

    Joshua FOLARANMI

    2008-12-01

    Full Text Available This project reports the design, construction and testing of a simple solar maize dryer. It is design in such a way that solar radiation is not incident directly on the maize, but preheated air warmed during its flow through a low pressure thermosphonic solar energy air heater or collector made up of an insulating material (polystyrene of size 100mmx50mmx25.4mm, absorber plate (aluminium sheet painted black of size 100mmx50mm and a cover glass (5mm thickness measuring 100mmx50mm all arranged in this order contributed to the heating. The test results gave temperature above 45OC in the drying chamber, and the moisture content of 50kg of maize reduced to about 12.5% in three days of 9hours each day of drying.

  15. Design and testing of solar dryers for processing food wastes

    Energy Technology Data Exchange (ETDEWEB)

    Nijmeh, M.N.; Ragab, A.S.; Emeish, M.S. [University of Jordan, Amman (Jordan). Mechanical Engineering Dept.; Jubran, B.A. [International Islamic University of Malaysia, Kaula Lumpur (Malaysia). Dept. of Mechanical Engineering

    1998-12-01

    This paper investigates the potential of using two solar dryers manufactured from locally available materials under Jordanian climatic conditions for drying food wastes for utilization as animal feed. The first dryer is a radiative-convective type, while the second is a solar boiler dryer. Tests were also conducted to investigate the nutritious values of the dried products and their suitability as animal feed. It was found from tests that the solar boiler dryer is more efficient than the radiative-convective dryer for producing animal feed in terms of both quality and quantity. The nutritious values of the end products from the dryers were found to be within the international recommended values used for feeding chickens. (author)

  16. Summary of the Solar Two Test and Evaluation Program

    Energy Technology Data Exchange (ETDEWEB)

    PACHECO,JAMES E.; REILLY,HUGH E.; KOLB,GREGORY J.; TYNER,CRAIG E.

    2000-02-08

    Solar Two was a collaborative, cost-shared project between eleven US industry and utility partners and the U. S. Department of Energy to validate molten-salt power tower technology. The Solar Two plant, located east of Barstow, CA, was comprised of 1926 heliostats, a receiver, a thermal storage system and a steam generation system. Molten nitrate salt was used as the heat transfer fluid and storage media. The steam generator powered a 10 MWe, conventional Rankine cycle turbine. Solar Two operated from June 1996 to April 1999. The major objective of the test and evaluation phase of the project was to validate the technical characteristics of a molten salt power tower. This paper describes the significant results from the test and evaluation activities.

  17. Standard Specification for Solar Simulation for Terrestrial Photovoltaic Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification provides means for classifying solar simulators intended for indoor testing of photovoltaic devices (solar cells or modules), according to their spectral match to a reference spectral irradiance, non-uniformity of spatial irradiance, and temporal instability of irradiance. 1.2 Testing of photovoltaic devices may require the use of solar simulators. Test Methods that require specific classification of simulators as defined in this specification include Test Methods E948, E1036, and E1362. 1.3 This standard is applicable to both pulsed and steady state simulators and includes recommended test requirements used for classifying such simulators. 1.4 A solar simulator usually consists of three major components: (1) light source(s) and associated power supply; (2) any optics and filters required to modify the output beam to meet the classification requirements in Section 4; and (3) the necessary controls to operate the simulator, adjust irradiance, etc. 1.5 A light source that does not mee...

  18. Near Earth Asteroid Solar Sail Engineering Development Unit Test Program

    Science.gov (United States)

    Lockett, Tiffany Russell; Few, Alexander; Wilson, Richard

    2017-01-01

    The Near Earth Asteroid (NEA) Scout project is a 30x20x10cm (6U) cubesat reconnaissance mission to investigate a near Earth asteroid utilizing an 86m2 solar sail as the primary propulsion system. This will be the largest solar sail NASA will launch to date. NEA Scout is a secondary payload currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis furthered understanding of thermal, stress, and dynamics of the stowed system and matured an integrated sail membrane model for deployed flight dynamics. This paper will address design, fabrication, and lessons learned from the NEA Scout solar sail subsystem engineering development unit. From optical properties of the sail material to folding and spooling the single 86m2 sail, the team has developed a robust deployment system for the solar sail. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

  19. Electricity savings with pellet stoves and solar heating in electrically heated houses; Elbesparing med pelletkaminer och solvaerme i direktelvaermda smaahus

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Tomas [Hoegskolan Dalarna, Borlaenge (Sweden)

    2004-07-01

    The aim of this study was to investigate how electrically heated houses can be converted to using wood pellet and solar heating. There are a large number of wood pellet stoves on the market. Many stoves have a water jacket, which gives an opportunity to distribute the heat to domestic hot water and a radiator heating system. Three typical Swedish houses with electric resistance heating have been studied. Fourteen different system concepts using wood pellet stoves and solar heating systems have been evaluated. The systems and the houses have been simulated in detail using TRNSYS. The houses have been divided in up to 10 different zones and heat transfer by air circulation through doorways and open doors have been simulated. The pellet stoves were simulated using a recently developed TRNSYS component, which models the start- and stop phases, emissions and the dynamic behaviour of the stoves. The model also calculates the CO-emissions. Simulations were made with one stove without a water jacket and two stoves with different fractions of the generated heat distributed in the water circuit. Simulations show that the electricity savings using a pellet stove are greatly affected by the house plan, the system choice, if the internal doors are open or closed and the desired level of comfort. Installing a stove with a water-jacket connected to a radiator system and a hot water storage has the advantage that heat can be transferred to domestic hot water and be distributed to other rooms. Such systems lead to greater electricity savings, especially in houses having a traditional layout. It was found that not all rooms needed radiators and that it was more effective in most cases to use a stove with a higher fraction of the heat distributed by the water circuit. The economic investigation shows that installing a wood pellet stove without a water jacket gives the lowest total energy- and capital costs in the house with an open plan (for today's energy prices and the

  20. The impact of cognitive testing on the welfare of group housed primates.

    Directory of Open Access Journals (Sweden)

    Jamie Whitehouse

    Full Text Available Providing cognitive challenges to zoo-housed animals may provide enriching effects and subsequently enhance their welfare. Primates may benefit most from such challenges as they often face complex problems in their natural environment and can be observed to seek problem solving opportunities in captivity. However, the extent to which welfare benefits can be achieved through programmes developed primarily for cognitive research is unknown. We tested the impact of voluntary participation cognitive testing on the welfare of a socially housed group of crested macaques (Macaca nigra at the Macaque Study Centre (Marwell Zoo. First, we compared the rate of self-directed and social behaviours on testing and non-testing days, and between conditions within testing days. Minimal differences in behaviour were found when comparing testing and non-testing days, suggesting that there was no negative impact on welfare as a result of cognitive testing. Lipsmacking behaviours were found to increase and aggressive interaction was found to decrease in the group as a result of testing. Second, social network analysis was used to assess the effect of testing on associations and interactions between individuals. The social networks showed that testing subjects increased their association with others during testing days. One interpretation of this finding could be that providing socially housed primates with an opportunity for individuals to separate from the group for short periods could help mimic natural patterns of sub-group formation and reunion in captivity. The findings suggest, therefore, that the welfare of captive primates can be improved through the use of cognitive testing in zoo environments.

  1. Social basis for solar cells on rented houses. Decision making in the PV-project in Heerhugowaard and the experiences of residents and neighbours

    International Nuclear Information System (INIS)

    Van Mierlo, B.; Van Roekel, A.; Westra, C.

    1994-11-01

    At the end of ten solar homes were officially opened in the newly built area Butterhuizen in Heerhugowaard, Netherlands. Those houses are provided with grid-connected solar cell systems on the roof to generate electricity that is supplied to the grid. The solar panels are owned by the regional energy utility (PEN) and allowed by the renter of the dwellings. In this report of the demonstration project three years of experiences and opinions of organizations and residents, involved in the project, are evaluated. The results give a first indication of the chances and constraints to apply solar cells in the housing construction in the Netherlands. 4 figs., 3 ills., 17 tabs., 13 refs., 3 appendices

  2. In Middle Europe, heating of an industrial building only with solar energy. First solar house industrial building with passive house standard in this size; In Mitteleuropa ein Industriegebaeude nur mit der Sonne heizen. Erstes Sonnenhaus Industriegebaeude mit Passivhaus-Standard in dieser Groesse

    Energy Technology Data Exchange (ETDEWEB)

    Huemer, Herbert [Xolar Renewable Energy Group HQ, Eberstalzell (Austria)

    2010-07-01

    Since 2008, Xolar Renewable Energy Group (Eberstalzell, Austria) combines the companies Sunmaster and Xolar in the most modern solar house in Europe with passive house standard. The contribution under consideration reports on the development of an industrial building which is heated entirely by solar energy and meets the standards of passive houses. All working places in the building should be sunny and free of draught. It does not use electrically powered heat pumps or refrigerators. All energy values calculated by simulation were achieved or partly exceeded. The savings in annual operating costs compared to conventional construction in factory buildings is approximately 192,000 Euro per year.

  3. Solar energy characteristics and some photovoltaic testing results in Jeddah

    Energy Technology Data Exchange (ETDEWEB)

    Mosalam Shaltout, M A

    1986-01-01

    The data for global radiation were analysed to investigate the correlation with climatological factors. Solar cell module testing under Jeddah climatic conditions was initiated in 1984-1985. The goal of this work was to study the performance and reliability of a commercially-available module in outdoor conditions in order to obtain information on solar cell system design, and to observe the influence of our specific climate conditions on module energy output. The use of results obtained for precise system sizing is discussed.

  4. Adapting and Pilot Testing a Parenting Intervention for Homeless Families in Transitional Housing.

    Science.gov (United States)

    Holtrop, Kendal; Holcomb, Jamila E

    2018-01-24

    Intervention adaptation is a promising approach for extending the reach of evidence-based interventions to underserved families. One highly relevant population in need of services are homeless families. In particular, homeless families with children constitute more than one third of the total homeless population in the United States and face several unique challenges to parenting. The purpose of this study was to adapt and pilot test a parenting intervention for homeless families in transitional housing. An established adaptation model was used to guide this process. The systematic adaptation efforts included: (a) examining the theory of change in the original intervention, (b) identifying population differences relevant to homeless families in transitional housing, (c) adapting the content of the intervention, and (d) adapting the evaluation strategy. Next, a pilot test of the adapted intervention was conducted to examine implementation feasibility and acceptability. Feasibility data indicate an intervention spanning several weeks may be difficult to implement in the context of transitional housing. Yet, acceptability of the adapted intervention among participants was consistently high. The findings of this pilot work suggest several implications for informing continued parenting intervention research and practice with homeless families in transitional housing. © 2018 Family Process Institute.

  5. Discrimination of tenants with a visual impairment on the housing market: Empirical evidence from correspondence tests.

    Science.gov (United States)

    Verhaeghe, Pieter-Paul; Van der Bracht, Koen; Van de Putte, Bart

    2016-04-01

    According to the social model of disability, physical 'impairments' become disabilities through exclusion in social relations. An obvious form of social exclusion might be discrimination, for instance on the rental housing market. Although discrimination has detrimental health effects, very few studies have examined discrimination of people with a visual impairment. We aim to study (1) the extent of discrimination of individuals with a visual impairment on the rental housing market and (2) differences in rates of discrimination between landowners and real estate agents. We conducted correspondence tests among 268 properties on the Belgian rental housing market. Using matched tests, we compared reactions by realtors and landowners to tenants with and tenants without a visual impairment. The results show that individuals with a visual impairment are substantially discriminated against in the rental housing market: at least one in three lessors discriminate against individuals with a visual impairment. We further discern differences in the propensity toward discrimination according to the type of lessor. Private landlords are at least twice as likely to discriminate against tenants with a visual impairment than real estate agents. At the same time, realtors still discriminate against one in five tenants with a visual impairment. This study shows the substantial discrimination against visually people with an impairment. Given the important consequences discrimination might have for physical and mental health, further research into this topic is needed. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Testing the principle of equivalence by solar neutrinos

    International Nuclear Information System (INIS)

    Minakata, Hisakazu; Washington Univ., Seattle, WA; Nunokawa, Hiroshi; Washington Univ., Seattle, WA

    1994-04-01

    We discuss the possibility of testing the principle of equivalence with solar neutrinos. If there exists a violation of the equivalence principle quarks and leptons with different flavors may not universally couple with gravity. The method we discuss employs a quantum mechanical phenomenon of neutrino oscillation to probe into the non-university of the gravitational couplings of neutrinos. We develop an appropriate formalism to deal with neutrino propagation under the weak gravitational fields of the sun in the presence of the flavor mixing. We point out that solar neutrino observation by the next generation water Cherenkov detectors can improve the existing bound on violation of the equivalence principle by 3-4 orders of magnitude if the nonadiabatic Mikheyev-Smirnov-Wolfenstein mechanism is the solution to the solar neutrino problem

  7. Testing the principle of equivalence by solar neutrinos

    International Nuclear Information System (INIS)

    Minakata, H.; Nunokawa, H.

    1995-01-01

    We discuss the possibility of testing the principle of equivalence with solar neutrinos. If there exists a violation of the equivalence principle, quarks and leptons with different flavors may not universally couple with gravity. The method we discuss employs the quantum mechanical phenomenon of neutrino oscillation to probe into the nonuniversality of the gravitational couplings of neutrinos. We develop an appropriate formalism to deal with neutrino propagation under the weak gravitational fields of the Sun in the presence of the flavor mixing. We point out that solar neutrino observation by the next generation water Cherenkov detectors can place stringent bounds on the violation of the equivalence principle to 1 part in 10 15 --10 16 if the nonadiabatic Mikheyev-Smirnov-Wolfenstein mechanism is the solution to the solar neutrino problem

  8. Empowering Distributed Solar PV Energy for Malaysian Rural Housing: Towards Energy Security and Equitability of Rural Communities

    Directory of Open Access Journals (Sweden)

    N.A. Ahmad

    2013-02-01

    Full Text Available This paper illustrates on how Malaysia’s development landscapes has been poweredby cheap oil and gas making it dependent and addicted on using large amounts of fossil fuels. As acountry that is primarily depended on fossil fuels for generating power supply, Malaysia needs tocogitate of long-term energy security due to fossil fuel depletion and peak oil issues. Loss of theseresources could leadto thereduction of power generation capacitywhich will threaten the stabilityof the electricity supply in Malaysia. This could potentially influence in an increase in electricitycosts which lead to a phase of power scarcity and load shedding for the country. With the risk ofinterrupted power supplies, rural households, especially those of low-income groups areparticularly vulnerable to the post-effects of a power outage and an inequitable distribution to thepeople. Distributed generation of electricity by solar PVs diminishes the vulnerability of thesehouseholds and can also offer an income to them by feeding the power supply to the national gridthrough Feed-in Tariff scheme. At the moment, the deployment of solar PV installations is still inthe introductory stage in Malaysia, where roof-mounted PV panels are only available to commercialand urban residential buildings. This is due to the lack of a suitable renewable energy policy forrural households and the high cost of the solar PV technology. This paper will put forward ananalysis for incorporating solar photovoltaic on roofs of rural houses by identifying the energyconsumption of these households and the extent to which PVs can alleviate electricity insecurity.The results present significant potential for distributed PV power generation in rural areas inMalaysia which shown a considerable amount of electricity needed to be harvested from roofmountedsolar PV for rural people in Malaysia.

  9. Solar Thermal Upper Stage Cryogen System Engineering Checkout Test

    Science.gov (United States)

    Olsen, A. D; Cady, E. C.; Jenkins, D. S.

    1999-01-01

    The Solar Thermal Upper Stage technology (STUSTD) program is a solar thermal propulsion technology program cooperatively sponsored by a Boeing led team and by NASA MSFC. A key element of its technology program is development of a liquid hydrogen (LH2) storage and supply system which employs multi-layer insulation, liquid acquisition devices, active and passive thermodynamic vent systems, and variable 40W tank heaters to reliably provide near constant pressure H2 to a solar thermal engine in the low-gravity of space operation. The LH2 storage and supply system is designed to operate as a passive, pressure fed supply system at a constant pressure of about 45 psia. During operation of the solar thermal engine over a small portion of the orbit the LH2 storage and supply system propulsively vents through the enjoy at a controlled flowrate. During the long coast portion of the orbit, the LH2 tank is locked up (unvented). Thus, all of the vented H2 flow is used in the engine for thrust and none is wastefully vented overboard. The key to managing the tank pressure and therefore the H2 flow to the engine is to manage and balance the energy flow into the LH2 tank with the MLI and tank heaters with the energy flow out of the LH2 tank through the vented H2 flow. A moderate scale (71 cu ft) LH2 storage and supply system was installed and insulated at the NASA MSFC Test Area 300. The operation of the system is described in this paper. The test program for the LH2 system consisted of two parts: 1) a series of engineering tests to characterize the performance of the various components in the system: and 2) a 30-day simulation of a complete LEO and GEO transfer mission. This paper describes the results of the engineering tests, and correlates these results with analytical models used to design future advanced Solar Orbit Transfer Vehicles.

  10. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  11. Environmental testing of flat plate solar cell modules

    Science.gov (United States)

    Griffith, J.; Dumas, L.; Hoffman, A.

    1978-01-01

    Commercially available flat-plate solar cell modules have been subjected to a variety of environmental tests designed to simulate service conditions. Among the tests are those simulating heat and rain, wind-driven rains, humidity and freezing, humidity and heat, humidity with a voltage bias, salt fog, hail impact, and fungus infestation. Tests for optical surface soiling and the combined effects of temperature, humidity and UV irradiation are under development. A correlation has been demonstrated between degradation caused by the qualification tests and such observed field effects as power loss.

  12. Experimental investigations on solar heating/heat pump systems for single family houses

    DEFF Research Database (Denmark)

    Andersen, Elsa; Perers, Bengt

    In the period 2013-2017 the project “Experimental investigations on solar heat pump systems for single family houses” is carried out at Department of Civil Engineering, Technical University of Denmark. The aim of this project is to increase the knowledge of the heat and mass transfer in the combi...

  13. Sandia Laboratories in-house activities in support of solar thermal large power applications

    Science.gov (United States)

    Mar, R. W.

    1980-01-01

    The development of thermal energy storage subsystems for solar thermal large power applications is described. The emphasis is on characterizing the behavior of molten nitrate salts with regard to thermal decomposition, environmental interactions, and corrosion. Electrochemical techniques to determine the ionic species in the melt and for use in real time studies of corrosion are also briefly discussed.

  14. A Unique test for Hubble's new Solar Arrays

    Science.gov (United States)

    2000-10-01

    In mid-October, a team from the European Space Agency (ESA) and NASA will perform a difficult, never-before-done test on one of the Hubble Space Telescope's new solar array panels. Two of these panels, or arrays, will be installed by astronauts in November 2001, when the Space Shuttle Columbia visits Hubble on a routine service mission. The test will ensure that the new arrays are solid and vibration free before they are installed on orbit. The test will be conducted at ESA's European Space Research and Technology Center (ESTEC) in Noordwijk, The Netherlands. Because of the array's size, the facility's special features, and ESA's longstanding experience with Hubble's solar arrays, ESTEC is the only place in the world the test can be performed. This test is the latest chapter in a longstanding partnership between ESA and NASA on the Hubble Space Telescope. The Large Space Simulator at ESTEC, ESA's world-class test facility, features a huge vacuum chamber containing a bank of extremely bright lights that simulate the Sun's intensity - including sunrise and sunset. By exposing the solar wing to the light and temperature extremes of Hubble's orbit, engineers can verify how the new set of arrays will act in space. Hubble orbits the Earth once every 90 minutes. During each orbit, the telescope experiences 45 minutes of searing sunlight and 45 minutes of frigid darkness. This test will detect any tiny vibrations, or jitters, caused by these dramatic, repeated changes. Even a small amount of jitter can affect Hubble's sensitive instruments and interfere with observations. Hubble's first set of solar arrays experienced mild jitter and was replaced in 1993 with a much more stable pair. Since that time, advances in solar cell technology have led to the development of even more efficient arrays. In 2001, NASA will take advantage of these improvements, by fitting Hubble with a third-generation set of arrays. Though smaller, this new set generates more power than the previous

  15. Evaluation of performance for solar house with Trombe wall. Part 6; Trombe kabeshiki solar house no hyoka kenkyu (toki tan`i ni okeru Trombe heki naihyomen kyuhonetsuryo no santei hoho no kento)

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, R.; Nakajima, Y. [Kogakuin University, Tokyo (Japan); Yoshida, N. [Nishimatsu Construction Co. Ltd., Tokyo (Japan); Watanabe, T. [Tokyo Electric Power Service Co. Ltd., Tokyo (Japan); Abe, H. [National Land Agency, Tokyo (Japan); Yamaga, K. [Mitsubishi Estate Co. Ltd., Tokyo (Japan)

    1997-11-25

    `Equivalent heat loss factor` used in the simplified load calculation method for the Trombe wall is a version modified to fit a solar house equipped with a Trombe wall. To compute the factor, it is necessary to input the quantities of Trombe wall inner surface absorbed/radiated heat for whose calculation the effect of the delay in solar heat storage by the Trombe wall has to be taken into consideration. The daily summation of the quantities of absorbed/radiated heat can be easily calculated using the day`s and the previous day`s insolation amounts. In this report, the hourly summation of the quantities of Trombe wall surface absorbed/radiated heat is performed by use of two variables which are the day`s and the previous day`s insolation amounts. In calculating the hourly summation of the quantities of absorbed/radiated heat, the daily summation of the quantities of absorbed/radiated heat is first calculated using the chart of predicted lines for the Trombe wall and, based on the data thus obtained, the quantities of absorbed/absorbed heat are divided and assigned to the respective hours and, as the result, approximations are obtained for the calculation of the hourly summation of the quantities of Trombe wall absorbed/radiated heat. A `time-dependent performance prediction curves for the Trombe wall` is proposed, which enables the visual comprehension of the effect of Trombe wall hourly units. 1 ref., 10 figs., 2 tabs.

  16. Progress and Strategies for Testing of Materials for Solar Panels

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah

    2017-04-25

    Accelerated testing is key to confident launch of a new product. However, for new products like solar panels, the best approach is not always clear. The challenge for materials manufacturers is that test times can be long. Also, small-coupon testing may not predict the behavior in the full-size module, but testing of the full-size module is too expensive. As a result, solar panel test standards like IEC 61215 are useful, but are not sufficient. Material manufacturers have needed to define their own test protocols. This presentation will review some historical data (e.g., data show that manufacturers are making great progress toward reducing encapsulant discoloration) and describe advances in material testing (for example, new techniques are being demonstrated on how to more quantitatively assess adhesion, detect tendency for delamination, and understand how encapsulant properties affect other properties like cracking of cells). The International PV Quality Assurance Task Force has been researching climate-specific weathering tests toward the goal of defining international standards that would simplify qualification and quality assurance testing for materials. The status of these tests and the strategies for how to organize these standards to best meet the needs of the industry will be discussed.

  17. A comparison of CHENATH, the Nationwide House Energy Rating Scheme Simulation Engine, with measured test cell data

    Energy Technology Data Exchange (ETDEWEB)

    Delsante, A.E. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Highett, VIC (Australia). Div. of Building Construction and Engineering

    1995-12-31

    The Nationwide House Energy Rating Scheme (NatHERS) uses a simulation program as its reference tool to evaluate the energy demand of buildings. The Commonwealth Scientific Industrial Research Organisation (CSIRO) developed software called CHENATH, is a significantly enhanced version of the CHEETAH simulation program. As part of the NatHERS development process, it was considered important to subject CHENATH to further testing. Two separate evaluation projects were undertaken. This paper describes one of these projects. CHENATH was compared with measured data from three test cells with single glazing, double glazing and no glazing. The solar radiation comparisons led to an improved model that accounts for anisotropic diffuse radiation. CHENATH significantly under-predicted the heating energy, but conclusions are difficult to draw because the actual heater used was very different from that assumed by the program. Temperature comparisons in the free running single-glazed cell showed that CHENATH`s new glazing model preformed significantly better than the old model. This exercise has reinforced the need for extreme care in designing, monitoring and describing test cells and for modellers to interpret the data supplied correctly. (author). 4 tabs., 3 figs., 4 refs.

  18. Solar cooling in the hardware-in-the-loop test; Solare Kuehlung im Hardware-in-the-Loop-Test

    Energy Technology Data Exchange (ETDEWEB)

    Lohmann, Sandra; Radosavljevic, Rada; Goebel, Johannes; Gottschald, Jonas; Adam, Mario [Fachhochschule Duesseldorf (Germany). Erneuerbare Energien und Energieeffizienz E2

    2012-07-01

    The first part of the BMBF-funded research project 'Solar cooling in the hardware-in-the-loop test' (SoCool HIL) deals with the simulation of a solar refrigeration system using the simulation environment Matlab / Simulink with the toolboxes Stateflow and Carnot. Dynamic annual simulations and DoE supported parameter variations were used to select meaningful system configurations, control strategies and dimensioning of components. The second part of this project deals with hardware-in-the-loop tests using the 17.5 kW absorption chiller of the company Yazaki Europe Limited (Hertfordshire, United Kingdom). For this, the chiller is operated on a test bench in order to emulate the behavior of other system components (solar circuit with heat storage, recooling, buildings and cooling distribution / transfer). The chiller is controlled by a simulation of the system using MATLAB / Simulink / Carnot. Based on the knowledge on the real dynamic performance of the chiller the simulation model of the chiller can then be validated. Further tests are used to optimize the control of the chiller to the current cooling load. In addition, some changes in system configurations (for example cold backup) are tested with the real machine. The results of these tests and the findings on the dynamic performance of the chiller are presented.

  19. Performance tests and efficiency analysis of Solar Invictus 53S - A parabolic dish solar collector for direct steam generation

    Science.gov (United States)

    Jamil, Umer; Ali, Wajahat

    2016-05-01

    This paper presents the results of performance tests conducted on Solar Invictus 53S `system'; an economically effective solar steam generation solution designed and developed by ZED Solar Ltd. The system consists of a dual axis tracking parabolic solar dish and bespoke cavity type receiver, which works as a Once Through Solar Steam Generator `OTSSG' mounted at the focal point of the dish. The overall performance and efficiency of the system depends primarily on the optical efficiency of the solar dish and thermal efficiency of the OTSSG. Optical testing performed include `on sun' tests using CCD camera images and `burn plate' testing to evaluate the sunspot for size and quality. The intercept factor was calculated using a colour look-back method to determine the percentage of solar rays focused into the receiver. Solar dish tracking stability tests were carried out at different times of day to account for varying dish elevation angles and positions, movement of the sunspot centroid was recorded and logged using a CCD camera. Finally the overall performance and net solar to steam efficiency of the system was calculated by experimentally measuring the output steam parameters at varying Direct Normal Insolation (DNI) levels at ZED Solar's test facility in Lahore, Pakistan. Thermal losses from OTSSG were calculated using the known optical efficiency and measured changes in output steam enthalpy.

  20. Liquid sodium testing of in-house phased array EMAT transducer for L-wave applications

    Energy Technology Data Exchange (ETDEWEB)

    Le Bourdais, F.; Le Polles, T. [Non Destructive Testing Department at the French Atomic Energy Commission (CEA), Saclay, 91191 Gif sur Yvette CEDEX, (France); Baque, F. [Department of Sodium Technology at the French Atomic Energy Commission (CEA), Cadarache, 13108 St Paul lez Durance CEDEX, (France)

    2015-07-01

    This paper describes the development of an in-house phased array EMAT transducer for longitudinal wave inspection in liquid sodium. The work presented herein is part of an undergoing project aimed at improving in-service inspection techniques for the ASTRID reactor project. The design process of the phased array EMAT probe is briefly explained and followed by a review of experimental test results. We first present test results obtained in the laboratory while the last part of the paper describes the liquid sodium testing and the produced ultrasound images. (authors)

  1. Liquid sodium testing of in-house phased array EMAT transducer for L-wave applications

    International Nuclear Information System (INIS)

    Le Bourdais, F.; Le Polles, T.; Baque, F.

    2015-01-01

    This paper describes the development of an in-house phased array EMAT transducer for longitudinal wave inspection in liquid sodium. The work presented herein is part of an undergoing project aimed at improving in-service inspection techniques for the ASTRID reactor project. The design process of the phased array EMAT probe is briefly explained and followed by a review of experimental test results. We first present test results obtained in the laboratory while the last part of the paper describes the liquid sodium testing and the produced ultrasound images. (authors)

  2. Radiation Testing of PICA at the Solar Power Tower

    Science.gov (United States)

    White, Susan

    2010-01-01

    Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

  3. Passive and hybrid solar manufactured housing and buildings. [Includes architectural drawings

    Energy Technology Data Exchange (ETDEWEB)

    Scholz, D; Bowling, C; Winter, S; Levy, E; Marks, R; Zgolinski, A

    1980-01-01

    The final design work on a passive solar two story modular home to be built by Unibilt Industries is summarized. After reviewing alternative insulation, glazing, and water wall schemes, five options were identified for detailed energy use and life cycle cost analysis. Using the PASCALC/SLR analysis procedure, the performance of the base case home and each of the energy conservation options was calculated. (MHR)

  4. Initial operation of a solar heating and cooling system in a full-scale solar building test facility

    Science.gov (United States)

    Knoll, R. H.; Miao, D.; Hamlet, I. L.; Jensen, R. N.

    1976-01-01

    The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.

  5. Housing and sustainable development: perspectives offered by thermal solar energy. Particle emissions: prospective investigation of primary particle emissions in France by 2030

    International Nuclear Information System (INIS)

    Brignon, J.M.; Cauret, L.; Sambat, S.

    2004-09-01

    This publication proposes two investigation reports. A first study proposes a prospective analysis of the housing 'stock' in France and the evolution of global energy consumptions and CO 2 emissions by the housing sector, a prospective study of space heating and hot water needs by defining reference scenarios as well as a target scenario for heating consumption (based on the factor 4 of reduction of emissions by 2050), and an assessment of the contribution of the thermal solar energy applied to winter comfort under the form of direct solar floors and passive solar contributions, and applied to hot water by 2050. The contribution of the thermal solar energy is studied within its regulatory context. An analysis of urban forms is also performed to assess the potential of integration of renewable energy solutions in the existing housing stock, and thus to assess the morphological limits of an attempt of generalized solarization of roofs. The second study proposes a detailed identification and assessment of the various sources of primary particles (combustion, industrial processes, mineral extraction and processing, road transport, waste processing and elimination, agriculture, natural sources, forest fires), providing more precise results and methodological complements for some sources. It also proposes a prospective assessment of emissions and identifies the main factors of particle concentrations in urban environment

  6. An improved dynamic test method for solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector...... parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content...... for the second-order differential term with 6–9min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87W/m2 and 5.22W/m2...

  7. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  8. Development and testing of technical measures for the abatement of PM10 emissions from poultry housings

    Energy Technology Data Exchange (ETDEWEB)

    Ogink, N.W.M.; Aarnink, A.J.A.; Mosquera, J.; Winkel, A. [Wageningen UR Livestock Research, Wageningen (Netherlands)

    2010-07-01

    In order to comply with the European Union's ambient air quality standards, the Netherlands must reduce emissions of PM10. As a contributor to PM10, the poultry industry must implement mitigation measures before 2012. An extensive research and development program was launched in 2008 to provide abatement technology for broiler and layer houses. This paper presented results from studies carried out in 2008 and 2009 by Wageningen UR Livestock Research. The supply industry and poultry farmers participated in the study in which different methods and approaches were examined, including bedding material, light schedules, oil spraying systems, ionization systems, water scrubbers, combined scrubbers, electrostatic filters, and dry filters. Most methods were first tested and optimized in small units at an experimental poultry facility Lelystad. Several methods were validated in a next step on poultry farms, where PM10 emissions were measured to establish official emission factors. The oil spraying system and ionization system were tested in broiler houses and are nearing implementation. Reductions in PM10 emissions by different methods ranged from no effect to levels of 60 per cent. An outlook on adequate dust abatement measures for poultry housings was also provided.

  9. Retrofitting Domestic Hot Water Heaters for Solar Water Heating Systems in Single-Family Houses in a Cold Climate: A Theoretical Analysis

    Directory of Open Access Journals (Sweden)

    Björn Karlsson

    2012-10-01

    Full Text Available One of the biggest obstacles to economic profitability of solar water heating systems is the investment cost. Retrofitting existing domestic hot water heaters when a new solar hot water system is installed can reduce both the installation and material costs. In this study, retrofitting existing water heaters for solar water heating systems in Swedish single-family houses was theoretically investigated using the TRNSYS software. Four simulation models using forced circulation flow with different system configurations and control strategies were simulated and analysed in the study. A comparison with a standard solar thermal system was also presented based on the annual solar fraction. The simulation results indicate that the retrofitting configuration achieving the highest annual performance consists of a system where the existing tank is used as storage for the solar heat and a smaller tank with a heater is added in series to make sure that the required outlet temperature can be met. An external heat exchanger is used between the collector circuit and the existing tank. For this retrofitted system an annual solar fraction of 50.5% was achieved. A conventional solar thermal system using a standard solar tank achieves a comparable performance for the same total storage volume, collector area and reference conditions.

  10. Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

    Energy Technology Data Exchange (ETDEWEB)

    Woods, J.; Winkler, J.; Christensen, D.; Hancock, E.

    2014-08-01

    Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

  11. 4. meeting on passive solar energy houses. Proceedings; 4. Passivhaus Tagung. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Feist, W [ed.; Sariri, V; Nagel, M [comps.; Passivhaus Institut, Darmstadt (Germany)

    2000-03-01

    This is the report on the 4th Passive Building Conference, which took place at Kassel on March 10/11, 2000. There were eight sections: (a) Planners' workshop; (b) Architecture; (c) Ventilation; (d) Construction practice; (e) Subjective users' comfort and measured results; (f) Practical implementation; (g) economic and ecological assessment; (h) Solar architecture; (i) Heat supply. It was considered particularly favourable that passive solar buildings do not only offer a solution to ecological problems but also a growing market. [German] Der Tagungsband der '4. Passivhaus Tagung', die von 10. bis 11. Maerz 2000 in Kassel stattgefunden hat, beinhalten Beitraege, die in acht Arbeitsgruppen vorgetragen worden: (a) Planer-Werkstatt; (b) Architektur; (c) Lueftungsplanung; (d) Baupraxis; (e) Wohnerfahrung, Messergebnisse; (f) Umsetzung; (g) oekonomische und oekologische Bewertung; (h) Solararchitektur; (i) Waermeversorgung. Es wird vom Herausgeber als besonders erfreulich herausgestellt, dass durch eine erfolgreiche Passivhaus-Entwicklung neben der Loesung der Klimaprobleme zugleich ein neuer Wachstumsmarkt geschaffen werde, der mit einer Mehrung von Wertschoepfung und Wohlstand verbunden ist. (AKF)

  12. 4. meeting on passive solar energy houses. Proceedings; 4. Passivhaus Tagung. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    Feist, W. [ed.; Sariri, V.; Nagel, M. [comps.] [Passivhaus Institut, Darmstadt (Germany)

    2000-03-01

    This is the report on the 4th Passive Building Conference, which took place at Kassel on March 10/11, 2000. There were eight sections: (a) Planners' workshop; (b) Architecture; (c) Ventilation; (d) Construction practice; (e) Subjective users' comfort and measured results; (f) Practical implementation; (g) economic and ecological assessment; (h) Solar architecture; (i) Heat supply. It was considered particularly favourable that passive solar buildings do not only offer a solution to ecological problems but also a growing market. [German] Der Tagungsband der '4. Passivhaus Tagung', die von 10. bis 11. Maerz 2000 in Kassel stattgefunden hat, beinhalten Beitraege, die in acht Arbeitsgruppen vorgetragen worden: (a) Planer-Werkstatt; (b) Architektur; (c) Lueftungsplanung; (d) Baupraxis; (e) Wohnerfahrung, Messergebnisse; (f) Umsetzung; (g) oekonomische und oekologische Bewertung; (h) Solararchitektur; (i) Waermeversorgung. Es wird vom Herausgeber als besonders erfreulich herausgestellt, dass durch eine erfolgreiche Passivhaus-Entwicklung neben der Loesung der Klimaprobleme zugleich ein neuer Wachstumsmarkt geschaffen werde, der mit einer Mehrung von Wertschoepfung und Wohlstand verbunden ist. (AKF)

  13. 10-MWe pilot-plant-receiver panel test requirements document solar thermal test facility

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-25

    Testing plans for a full-scale test receiver panel and supporting hardware which essentially duplicate both physically and functionally, the design planned for the Barstow Solar Pilot Plant are presented. Testing is to include operation during normal start and shutdown, intermittent cloud conditions, and emergencies to determine the panel's transient and steady state operating characteristics and performance under conditions equal to or exceeding those expected in the pilot plant. The effects of variations of input and output conditions on receiver operation are also to be investigated. Test hardware are described, including the pilot plant receiver, the test receiver assembly, receiver panel, flow control, electrical control and instrumentation, and structural assembly. Requirements for the Solar Thermal Test Facility for the tests are given. The safety of the system is briefly discussed, and procedures are described for assembly, installation, checkout, normal and abnormal operations, maintenance, removal and disposition. Also briefly discussed are quality assurance, contract responsibilities, and test documentation. (LEW)

  14. Testing and further development of a solar absorption cooling plant

    Science.gov (United States)

    Amannsberger, K.; Heckel, H.; Kreutmair, J.; Weber, K. H.

    1984-12-01

    Ammonia water absorption cooling units using the process heat of line-focusing solar collectors were developed and tested. Reduction of the evaporation temperature to minus 10 C; development of an air-cooled rectifying device for the refrigerant vapor; dry cooling of absorber and condenser by natural draft; refrigerating capacities of 14 to 10 kW which correspond to air temperatures of 25 to 40 C and 24 kW power consumption to heat the machine; auxiliary power requirement 450 W; full compatibility with changing heat input and air temperature, adaptation by automatic stabilization effects; and power optimization under changing boundary conditions by a simple regulating procedure independent of auxiliary power are achieved. The dynamic behavior of the directly linked collector-refrigeration machine system was determined. Operating conditions, market, and economic viability of solar cooling in third-world countries are described. Ice production procedures using absorption cooling units are demonstrated.

  15. Sizing and preliminary hardware testing of solar powered UAV

    Directory of Open Access Journals (Sweden)

    S. Jashnani

    2013-12-01

    Full Text Available Integrating solar energy into modern aircraft technology has been a topic of interest and has received a lot of attention from researchers over the last two decades. A few among the many potential applications of this technology are the possibility of continuous self sustained flight for purposes such as information relay, surveillance and monitoring. This paper discusses the altitude and payload mass, as independent parameters, and their influence on the size and design of the aircraft. To estimate available solar power, two different models have been presented; one for low altitudes and the other for high altitudes. An engineering ground model was built to simulate the power and propulsion system over 24 h of continuous operation. The paper presents data from tests performed till date and lessons learnt while dealing with the construction of the engineering ground model as well as changes that can be made to improve the design.

  16. Testing, development and demonstration of large scale solar district heating systems

    DEFF Research Database (Denmark)

    Furbo, Simon; Fan, Jianhua; Perers, Bengt

    2015-01-01

    In 2013-2014 the project “Testing, development and demonstration of large scale solar district heating systems” was carried out within the Sino-Danish Renewable Energy Development Programme, the so called RED programme jointly developed by the Chinese and Danish governments. In the project Danish...... know how on solar heating plants and solar heating test technology have been transferred from Denmark to China, large solar heating systems have been promoted in China, test capabilities on solar collectors and large scale solar heating systems have been improved in China and Danish-Chinese cooperation...

  17. Housing a Raspberry Pi Connected AS-1 Seismometer in a Solar-Paneled Shed

    Science.gov (United States)

    Marton, F.; Tokman, T. L.; Echreshzadeh, M.; Palaric, K. D.; Filippone, N. V.; Sivo, J.

    2016-12-01

    Last year, students working on the SeismoSTEM project at Bergen Community College successfully manufactured and assembled an AS-1 seismometer1. However, issues students encountered were not knowing where to place the TC-1 and AS-1 seismometers, nor how to configure the instruments with a computer for monitoring and measuring earthquakes. Our solution was to purchase a Raspberry Pi 3 model B, which has four USB ports and a Wi-Fi adapter. We then installed the Raspbian operating system that can run jAmaSeis, which allows for the collection and analysis of seismic data. In terms of the shed that was constructed last summer2, we installed roof shingles, as well as a ventilation system to prevent overheating. The seismometers will then be placed on a concrete slab. In the future, we plan on applying a wood varnish around the exterior of the shed, as well as gravel around the shed for water drainage as well as to make it more visually appealing. Moreover, we plan on mounting a 170-W solar panel on the roof to charge a 12-V deep cycle marine battery, which will provide electricity to the system. References: 1Tokman, T.L. et al., What's shaking? Manufacturing & assembling an AS-1 educational seismometer for undergraduate stem research, Geological Society of America Abstracts with Programs. Vol. 47, No. 7, p.524, 2015. 2Palaric, K.D., et al., Constructing a solar-powered seismic station for educational seismometers, Geological Society of America Abstracts with Programs. Vol. 47, No. 7, p.524, 2015.

  18. Solar Energy Education. Home economics: student activities. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-01

    A view of solar energy from the standpoint of home economics is taken in this book of activities. Students are provided information on solar energy resources while performing these classroom activities. Instructions for the construction of a solar food dryer and a solar cooker are provided. Topics for study include window treatments, clothing, the history of solar energy, vitamins from the sun, and how to choose the correct solar home. (BCS)

  19. Testing parasite 'intimacy': the whipworm Trichuris muris in the European house mouse hybrid zone.

    Science.gov (United States)

    Wasimuddin; Bryja, Josef; Ribas, Alexis; Baird, Stuart J E; Piálek, Jaroslav; Goüy de Bellocq, Joëlle

    2016-05-01

    Host-parasite interaction studies across hybrid zones often focus on host genetic variation, treating parasites as homogeneous. 'Intimately' associated hosts and parasites might be expected to show similar patterns of genetic structure. In the literature, factors such as no intermediate host and no free-living stage have been proposed as 'intimacy' factors likely constraining parasites to closely follow the evolutionary history of their hosts. To test whether the whipworm, Trichuris muris, is intimately associated with its house mouse host, we studied its population genetics across the European house mouse hybrid zone (HMHZ) which has a strong central barrier to gene flow between mouse taxa. T. muris has a direct life cycle and nonmobile free stage: if these traits constrain the parasite to an intimate association with its host we expect a geographic break in the parasite genetic structure across the HMHZ. We genotyped 205 worms from 56 localities across the HMHZ and additionally T. muris collected from sympatric woodmice (Apodemus spp.) and allopatric murine species, using mt-COX1, ITS1-5.8S-ITS2 rDNA and 10 microsatellites. We show four haplogroups of mt-COX1 and three clear ITS1-5.8S-ITS2 clades in the HMHZ suggesting a complex demographic/phylogeographic history. Microsatellites show strong structure between groups of localities. However, no marker type shows a break across the HMHZ. Whipworms from Apodemus in the HMHZ cluster, and share mitochondrial haplotypes, with those from house mice. We conclude Trichuris should not be regarded as an 'intimate' parasite of the house mouse: while its life history might suggest intimacy, passage through alternate hosts is sufficiently common to erase signal of genetic structure associated with any particular host taxon.

  20. Preventing nuclear explosive testing. Submitted to the House of Representatives, Ninety-Ninth Congress, First Session

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    H.J. Resolution 3 banning the testing of nuclear weapons over 150 kilotons seeks to slow the arms race by urging Congress to ratify the 1974 Threshold Test Ban Treaty and the 1976 Peaceful Nuclear Explosions Treaty and urging the President to resume negotiations with the Soviet Union. The House Foreign Affairs Committee report supports the concept after a series of hearings with verification experts and the weapons and intelligence establishments. Verification and weapons reliability were the key issues of concern, but the committee concluded that politics rather than technology prevented a comprehensive test ban. The report also includes the reminder in the minority view that talks were suspended after the Soviet invasion of Afghanistan and that scientists need further testing to make weapons safer and less vulnerable to terrorist action

  1. Testing of Solar Heated Domestic Hot Water System for Solahart Scandinavia ApS

    DEFF Research Database (Denmark)

    Andersen, Elsa

    1997-01-01

    The solar heating system marketed by Solahart Scandinavia ApS was tested in the Institutes test facility for SDHWsystems. The test results are described in the report.......The solar heating system marketed by Solahart Scandinavia ApS was tested in the Institutes test facility for SDHWsystems. The test results are described in the report....

  2. 太阳能技术在“绿色凹宅”中的应用%Application of Solar Energy Technology in Green Concave House

    Institute of Scientific and Technical Information of China (English)

    莫理莉

    2014-01-01

    This paper introduced the application of solar energy technology in green concave house.The grid-connection photovoltaic power generation was used,which sent the redundant power back to the power network.The photovoltaic solar-thermal integrated solar panels provided the output of electricity and daily at the same time.The smart home system provided the comfortable environment for green concave house.The green concave house is a successful and low energy consumption example,which could provide references for the area of abundant solar energy and dispersal residence.%介绍了太阳能技术在“绿色凹宅”中的应用。采用的并网型太阳能光伏发电系统,当有余电时可回馈电网。铺设的光伏光热一体化太阳能板,在电力输出的同时提供生活热水。智能家居系统给“绿色凹宅”提供舒适的环境。“绿色凹宅”是一个比较成功的环保、低能耗的住宅实例,对太阳能资源丰富而又居住分散的地区有很好的借鉴意义。

  3. Development and Testing of the Solar System Concept Inventory

    Science.gov (United States)

    Hornstein, Seth D.; Prather, E. E.; English, T. R.; Desch, S. M.; Keller, J. M.; Collaboration of Astronomy Teaching Scholars CATS

    2011-01-01

    Trying to assess if our students really understand the ideas we present in class can be difficult. Concept inventories are research-validated assessment tools that can provide us with data to better understand whether we are successful in the classroom. The idea for the Solar System Concept Inventory (SSCI) was born after realizing that no concept inventory currently available covered details regarding the formation and evolution of our solar system. Topics were selected by having faculty identify the key concepts they address when teaching about the solar system and interviewing students in order to identify common naive ideas and reasoning difficulties relating to these key topics. Beginning in fall of 2008, a national multi-institutional field test began which would eventually involve nearly 2500 students and 17 instructors from 10 different institutions. After each round of testing, a group of instructors from multiple institutions around the country worked together to analyze the data and revise or eliminate underperforming questions. Each question was examined using a combination of point biserial, percent correct on the pre-test, and item difficulty to determine if the question was properly differentiating student understanding while also ensuring the question was not too easy or too hard. In this talk, I will present an overall outline of the development of the SSCI as well as the final testing results. The final version of the SSCI can be found at http://casa.colorado.edu/ hornstei/ssci/. This material is based upon work supported by the National Science Foundation under Grant No. 0715517, a CCLI Phase III Grant for the Collaboration of Astronomy Teaching Scholars (CATS). Any findings expressed in this material are those of the authors and do not necessarily reflect the views of the NSF.

  4. Final report : testing and evaluation for solar hot water reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, Thomas P. (University of New Mexico, Albuquerque, NM); He, Hongbo (University of New Mexico, Albuquerque, NM); Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Burch, Jay (National Renewable Energy Laboratory, Golden CO)

    2011-07-01

    Solar hot water (SHW) systems are being installed by the thousands. Tax credits and utility rebate programs are spurring this burgeoning market. However, the reliability of these systems is virtually unknown. Recent work by Sandia National Laboratories (SNL) has shown that few data exist to quantify the mean time to failure of these systems. However, there is keen interest in developing new techniques to measure SHW reliability, particularly among utilities that use ratepayer money to pay the rebates. This document reports on an effort to develop and test new, simplified techniques to directly measure the state of health of fielded SHW systems. One approach was developed by the National Renewable Energy Laboratory (NREL) and is based on the idea that the performance of the solar storage tank can reliably indicate the operational status of the SHW systems. Another approach, developed by the University of New Mexico (UNM), uses adaptive resonance theory, a type of neural network, to detect and predict failures. This method uses the same sensors that are normally used to control the SHW system. The NREL method uses two additional temperature sensors on the solar tank. The theories, development, application, and testing of both methods are described in the report. Testing was performed on the SHW Reliability Testbed at UNM, a highly instrumented SHW system developed jointly by SNL and UNM. The two methods were tested against a number of simulated failures. The results show that both methods show promise for inclusion in conventional SHW controllers, giving them advanced capability in detecting and predicting component failures.

  5. Accelerated stress testing of amorphous silicon solar cells

    Science.gov (United States)

    Stoddard, W. G.; Davis, C. W.; Lathrop, J. W.

    1985-01-01

    A technique for performing accelerated stress tests of large-area thin a-Si solar cells is presented. A computer-controlled short-interval test system employing low-cost ac-powered ELH illumination and a simulated a-Si reference cell (seven individually bandpass-filtered zero-biased crystalline PIN photodiodes) calibrated to the response of an a-Si control cell is described and illustrated with flow diagrams, drawings, and graphs. Preliminary results indicate that while most tests of a program developed for c-Si cells are applicable to a-Si cells, spurious degradation may appear in a-Si cells tested at temperatures above 130 C.

  6. Tank testing of a 2500-cm2 solar panel

    Science.gov (United States)

    Bever, R. S.; Staskus, J.

    1981-01-01

    A 50 cm by 50 cm solar array panel test patch was investigated for spacecraft charging and arcing effects. Bombardment with monochromatic electron was carried out. Some objectives of the test were: (1) to estimate at what voltage of electron bombardment arcing would be probable; (2) to find whether the arc's energy would be tolerable or damagingly large; (3) to try and separate thermal and photoeffects; and, (4) to see whether materials used were such as to minimize arcing. Some conclusions were: In sunlight the tracking data relay satellite's solar panel which has ceria glass on the front and conductive paint on the backside is probably a good design for reducing charge-up. In a geomagnetic substorm simulated in testing there will be arcing at the interconnects during eclipse and transitions into and out of eclipse in testing especially in view of the very cold temperatures that will be reached by this lightweight array. Ceria-doped glass is preferred to fused silica glass for reducing charge build up. The Kapton bare patch should still be conductively painted. The differential voltages on the panel determine when arcing first begins, and the electron beam voltages vary depending upon whether the metallic structure is directly grounded or semifloating.

  7. Investigation of water accumulation in an offgas test facility HEPA housing

    International Nuclear Information System (INIS)

    Speed, D.L.; Burns, D.B.; Van Pelt, W.B.; Burns, H.H.

    1997-01-01

    The Consolidated Incineration Facility, at the Department of Energy's Savannah River Site, is designed to treat solid and liquid RCRA hazardous and mixed wastes generated by site operations and clean-up activities. During CIF's pretrial burn campaigns in 1995, an appreciable amount of water was recovered from the HEPA housings. Questions were immediately raised as to the source of the water, and the degree of wetness of the filters during operation. There are two primary issues involved: Water could reduce the life expectancy and performance of the HEPA filters, housing, and associated ducting, and wet HEPAs also present radiological concerns for personnel during filter change-out. A similar phenomenon was noted at the Offgas Components Test Facility (OCTF), a 1/10 scale pilot of CIF's air pollution control system. Tests at OCTF indicated the water's most likely origin to be vapor condensing out from the flue gas stream due to excessive air in-leakage at housing door seals, ducting flanges, and actual holes in the ducting. The rate of accumulation bears no statistical correlation to such process parameters as steam flow, reheater outlet temperature and offgas velocity in the duct. Test results also indicated that the HEPA filter media is moistened by the initial process flow while the facility is being brought on line. However, even when the HEPA filters were manually drenched prior to startup, they became completely dry within four hours of the time steam was introduced to the reheater. Finally, no demonstrable relationship was found between the degree of filter media wetness and filter dP

  8. Using the building energy simulation test (BESTEST) to evaluate CHENATH, the Nationwide House Energy Rating Scheme Simulation Engine

    Energy Technology Data Exchange (ETDEWEB)

    Delsante, A.E. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Highett, VIC (Australia). Div. of Building Construction and Engineering

    1995-12-31

    The Nationwide House Energy Rating Scheme (NatHERS) uses a simulation program as its reference tool to evaluate the energy demand of buildings. The Commonwealth Scientific Industrial Research Organisation (CSIRO) developed software called CHENATH, is a significantly enhanced version of the CHEETAH simulation program. As part of the NatHERS development process, it was considered important to subject CHENATH to further testing. Two separate evaluation projects were undertaken. This paper describes one of these projects. CHENATH was compared with a reference set of eight internationally recognized simulation programs using the BESTEST methodology. Annual heating and cooling energy requirements were compared for a specified set of variations on a simple double-glazed building. Annual incident and transmitted solar radiation was also compared, for which CHENATH agreed very well with the reference set. It also agreed well for heating energy, but tended to over-predict cooling energy. This is largely because it controls an environmental temperature rather than the required air temperature. For the same reason CHENATH over-predicted heating and cooling demands. No major discrepancies were found that would suggest bugs in the program. (author). 4 tabs., 10 figs., 4 refs.

  9. A long-term analysis of Pt counter electrodes for Dye-sensitized Solar Cells exploiting a microfluidic housing system

    Energy Technology Data Exchange (ETDEWEB)

    Sacco, Adriano, E-mail: adriano.sacco@iit.it [Center for Space Human Robotics @Polito, Istituto Italiano di Tecnologia, Corso Trento 21, 10129 Torino (Italy); Pugliese, Diego; Lamberti, Andrea [Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Castellino, Micaela; Chiodoni, Angelica [Center for Space Human Robotics @Polito, Istituto Italiano di Tecnologia, Corso Trento 21, 10129 Torino (Italy); Virga, Alessandro [Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy); Bianco, Stefano [Center for Space Human Robotics @Polito, Istituto Italiano di Tecnologia, Corso Trento 21, 10129 Torino (Italy); Applied Science and Technology Department, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino (Italy)

    2015-07-01

    The study of the degradation process occurring in Dye-sensitized Solar Cells (DSCs) is still a hot topic, in view of the final industrialization and application of this class of devices. Currently the long-term analysis of DSCs is carried out on the entire devices, while the monitoring of cell components cannot be performed in situ directly on the materials, but only through indirect methods. In this paper we report on the analysis of two different kinds of Pt counter electrodes through direct measurements performed under real operating conditions, thanks to the use of a home-made microfluidic housing system, which allows the opening and the investigation of the cell components. The counter electrode samples were studied through X-Ray Photoelectron Spectroscopy, Field Emission Scanning Electron Microscopy, Energy Dispersive X-ray Spectroscopy, UV–visible Spectroscopy and Electrochemical Impedance Spectroscopy for a period longer than 1 year. The results showed that the performances of both classes of Pt counter electrodes remained stable for all the investigation period, despite some slight variation of the morphology. DSCs fabricated employing aged counter electrodes exhibited the same photovoltaic performance behavior of reference cells using fresh-produced counter electrodes, thus demonstrating that both class of materials do not undergo degradation during normal operating conditions. - Highlights: • The analysis of Pt counter electrodes for Dye-sensitized Solar Cells was carried out. • Two families of counter electrodes were studied for a period longer than 1 year. • The analyzed samples were investigated in real operating condition. • A small detachment of the Pt clusters in the thermal samples was observed. • The charge transfer properties remained unchanged for all the investigation period.

  10. The impact of the year-on-year variation in the intensity of solar radiation on the energy intensity of low-energy and passive houses

    Directory of Open Access Journals (Sweden)

    Šubrt Roman

    2017-01-01

    Full Text Available Solar radiation is a significant segment of heat gains in the operation of buildings. The importance of this segment is highlighted by lowering the energy performance of buildings. The current condition of assessment considers the standard values of solar radiation but these are often very different from the fair values. In the contribution it draws attention to not only to on-year variation in solar fluctuations in the intensity of solar radiation and its significant long-term deviation from the standard values but also to the impact to energy building in reliance to its energy intensity. The attention will be focused also to different values in standards valid in the Czech Republic. This specification of energy assessment of buildings is not only necessary to approximate calculations of real state, but mainly because we can expect more disputes about if a building has declared calculating the parameters of a building with nearly zero-energy or passive house.

  11. Assessment of the energy performance of the solar space system attached to the CE – INCERC Bucharest experimental house – experimental validation

    Directory of Open Access Journals (Sweden)

    Dan CONSTANTINESCU

    2010-01-01

    Full Text Available The INCERC Bucharest experimental house is equipped on the Southern façade with a ventilated solar space. The solar space ensures the ventilation of the entire building at a constant rate of 0.60 exchanges / h during the cold season, by inletting the pre-heated space in the greenhouse space. In the hot season the system ensures the building reversible ventilation by providing the fresh air rate by air suction in the building Northern zone, a consequence of the natural draught effect ensured by the solar space. This report presents the experiments performed in the season 2008-2009 and the experimental validation of the mathematical model used in assessing the solar space energy performance in the heating season.

  12. Simulation study on reduction of peak power demand and energy consumption in residential houses with solar thermal and PV systems; Taiyo energy riyo jutaku no fuka heijunka oyobi energy sakugen koka no simulation ni yoru kento

    Energy Technology Data Exchange (ETDEWEB)

    Endo, T. [Yokohama City Office, Yokohama (Japan); Udagawa, M. [Kogakuin Univ., Tokyo (Japan). Faculty of Engineering

    1995-11-20

    In this study, taking the all factors involved in the energy consumption in residential houses as subjects, the effectiveness of the solar PV system and solar thermal utilizing system in residential houses has been studied by simulating a model residential house considering the improvement of the residual environment in the future. Therefore, a model residual house is assumed, 18 kinds of combinations of construction style, cooling and heating type and solar energy utilizing form are assumed and year round simulation is carried out. The conclusions obtained by the simulation are as follows. The energy consumption in residential houses may decrease greatly by using a solar hot water supplying system. If combined with a solar PV system, the energy consumption in one year is about 8.7 to 9.7 MWh. The combined use of a solar thermal utilizing system and a PV system is more effective to reduce the second-time energy in comparison with the PV system only. 36% of the space heating energy consumption may be decreased by using the solar space heating system, but the decrease effect of the energy consumption of the solar space heating system is smaller than the solar hot water supplying system. 12 refs., 26 figs., 3 tabs.

  13. Energy Performance and Thermal Comfort of a High Efficiency House: RhOME for denCity, Winner of Solar Decathlon Europe 2014

    Directory of Open Access Journals (Sweden)

    Gabriele Battista

    2015-07-01

    Full Text Available The increase of people living in large cities and the expansion of new urban areas are keys to defining new sustainable models. It is estimated that about 70% of the EU population lives in urban areas, and it is expected to reach 80% by 2030. Consequently, it is important to find a new concept of buildings that can reduce the total energy consumption. The Solar Decathlon is an international university competition, born in 2002, created by the U.S. State Energy Department (DOE. Students are challenged to design and operate a full-scale, innovative and sustainable house able to exploit solar radiation as its sole energy source. The objective of the competition is to promote research and education in sustainable architecture and solar energy fields. This paper presents an overview on the contribution of LIFT (Interdisciplinary Laboratory of Technical Physics of Roma Tre University to the winning project of the Solar Decathlon Europe 2014 competition: The RhOME for denCity. This project consists of a building properly designed to produce a solar-powered house that is cost-effective, energy-efficient, and attractive.

  14. New Whole-House Solutions Case Study: Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes - Pacific Northwest

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-05-01

    This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH). In this project, the Northwest Energy Efficient Manufactured Housing Program worked with Building America Partnership for Improved Residential Construction and Bonneville Power Administration to help four factory homebuilders build prototype zero energy ready manufactured homes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual % savings varies depending on choice of heating equipment and climate zone). Previous phases of this project created a HPMH specification and prototyped individual measures from the package to obtain engineering approvals and develop preliminary factory construction processes. This case study describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability. Monitoring is expected to continue into 2016.

  15. PID Testing Method Suitable for Process Control of Solar Cells Mass Production

    Directory of Open Access Journals (Sweden)

    Xianfang Gou

    2015-01-01

    Full Text Available Voltage bias of several hundred volts which are applied between solar cells and module frames may lead to significant power losses, so-called potential-induced degradation (PID, in normal photovoltaic (PV installations system. Modules and minimodules are used to conduct PID test of solar cells. The test procedure is time consuming and of high cost, which cannot be used as process monitoring method during solar cells fabrication. In this paper, three kinds of test including minimodule, Rsh, and V-Q test are conducted on solar cells or wafers with SiNx of different refractive index. All comparisons between test results of Rsh, V-Q, and minimodule tests have shown equal results. It is shown that Rsh test can be used as quality inspection of solar cells and V-Q test of coated wafer can be used as process control of solar cells.

  16. Simulated hail impact testing of photovoltaic solar panels

    Science.gov (United States)

    Moore, D.; Wilson, A.; Ross, R.

    1978-01-01

    Techniques used to simulate and study the effect of hail on photovoltaic solar panels are described. Simulated hail stones (frozen ice spheres projected at terminal velocity) or steel balls were applied by air guns, gravity drop, or static loading. Tests with simulated hail and steel balls yielded different results. The impact strength of 10 commercially available flat-plate photovoltaic modules was tested. It was found that none of the six panel designs incorporating clear potting silicone material as the outermost layer remained undamaged by 1-in. simulated hailstones, while a photovoltaic module equipped with a 0.188-in.-thick acrylic cover sheet would be able to withstand the impact of a 2-in.-diameter hailstone.

  17. Simulation and optimization study on a solar space heating system combined with a low temperature ASHP for single family rural residential houses in Beijing

    DEFF Research Database (Denmark)

    Deng, Jie; Tian, Zhiyong; Fan, Jianhua

    2016-01-01

    A pilot project of the solar water heating system combined with a low temperature air source heat pump (ASHP) unit was established in 2014 in a detached residential house in the rural region of Beijing, in order to investigate the system application prospect for single family houses via system...... optimization design and economic analysis. The established system was comprised of the glass heat-pipe based evacuated tube solar collectors with a gross area of 18.8 m2 and an ASHP with a stated heating power of 8 kW for the space heating of a single family rural house of 81.4 m2. The dynamic thermal...... with good building insulation were undertaken to figure out the system economical efficiency in the rural regions of Beijing. The results show that the payback periods of the solar space heating system combined with the ASHP with the collector areas 15.04-22.56 m2 are 17.3-22.4 years for the established...

  18. Measured Whole-House Performance of TaC Studios Test Home

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.; Curtis, O. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.; Stephenson, R. [Partnership for Home Innovation (PHI), Upper Marlboro, MD (United States). Southface Energy Inst.

    2013-12-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach topotential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaCStudios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this homewas evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored todetermine their impact on overall energy consumption.

  19. Measured Whole-House Performance of TaC Studios Test Home

    Energy Technology Data Exchange (ETDEWEB)

    Butler, T. [Southface Energy Institute, Upper Marlboro, MD (United States); Curtis, O. [Southface Energy Institute, Upper Marlboro, MD (United States); Stephenson, R. [Southface Energy Institute, Upper Marlboro, MD (United States)

    2013-12-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

  20. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for apartment houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Shugo jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    This report describes the fiscal 1976 research result on solar cooling/heating and hot water supply system for apartment houses. In the system research, comparative study was made on facility costs and operation costs per heat load between previous and solar cooling/heating and hot water supply systems for apartment houses. In the working design for apartment houses, various calculation necessary for start of work, and preparation of detail drawings and specifications were made. In development of solar collector, the test loop and collector were prepared using full-scale collector elements for medium-scale performance tests. In development of heat accumulator, inorganic hydrate was selected as heat storage material using latent heat for the confirmation test of basic physical properties. In development of solar cooling/heating equipment, the confirmation test of Rankine engine's performance, controllability and durability was made under real load. In addition, the refrigerator of nearly 20 tons of refrigeration driven by Rankine engine was fabricated, (NEDO)

  1. Solar Energy and You.

    Science.gov (United States)

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    This booklet provides an introduction to solar energy by discussing: (1) how a home is heated; (2) how solar energy can help in the heating process; (3) the characteristics of passive solar houses; (4) the characteristics of active solar houses; (5) how solar heat is stored; and (6) other uses of solar energy. Also provided are 10 questions to…

  2. Simulation study on single family house with solar floor and domestic hot water heating system by EESLISM; EESLISM ni yoru taiyonetsu danbo kyuto jutaku no simulation

    Energy Technology Data Exchange (ETDEWEB)

    Roh, H; Udagawa, M [Kogakuin University, Tokyo (Japan)

    1997-11-25

    Indoor thermal conditions and energy performance were simulated, by the aid of EESLISM as a common simulation program for indoor thermal conditions and energy systems, for an actual two-storied single family house equipped with solar-heated floors and a domestic hot water (DHW) heating system, in order to investigate applicability of the simulation program. The house, built in Shibuya Ward in Tokyo, has a total floor area of 164m{sup 2}, with a living room, dining room and study heated by the solar system for a total floor area of 35m{sup 2}. A heat-storage tank is provided, dedicated to the DHW system. The solar collector is of flat type, with selectively light-absorbing planes, having a total collector area of 11.46m{sup 2}. The operating conditions of the floor-heating and DHW systems are almost reproduced. It is necessary to take surrounding conditions into consideration; solar radiation in daytime will be overestimated if adjacent buildings are neglected to give higher temperature in the space and on the wall on the south than the observed level. 6 refs., 5 figs., 1 tab.

  3. TESTING AT NREL OF THE MINIPILOT SOLAR SYSTEM FOR HAZARDOUS WASTE THERMAL DESTRUCTION

    Science.gov (United States)

    A minipilot solar system (MSS) was built at MRI, transported to the National Renewable Energy Laboratory (NREL), and tested at NREL's high flux solar furnace. The MSS involved combustion of a liquid feed in a combustion reactor equipped with a quartz window at one end for solar i...

  4. Sustainable Plus-energy Houses

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    This study is an outcome of Elforsk, project number 344-060, Bæredygtige Energi-Plus huse (Sustainable plus-energy houses). The focus of this report is to document the approach and the results of different analyses concerning a plus-energy, single family house. The house was designed...... for an international student competition, Solar Decathlon Europe 2012 and after the competition it was used as a full-scale experimental facility for one year. During this period, different heating and cooling strategies were tested and the performance of the house regarding the thermal indoor environment and energy...... was monitored. This report is structured as follows. Chapter 1 presents the project and briefly explains the different phases of the project. The details of the house’s construction and its HVAC system are explained in Chapter 2, along with the energy efficiency measures and innovations. Chapter 3 introduces...

  5. Testing of indoor radon-reduction techniques in basement houses having adjoining wings. Final report, August 1988-September 1989

    International Nuclear Information System (INIS)

    Messing, M.

    1990-11-01

    The report gives results of tests of indoor radon reduction techniques in 12 existing Maryland houses, with the objective of determining when basement houses with adjoining wings require active soil depressurization (ASD) treatment of both wings, and when treatment of the basement alone is sufficient. In five basement houses with adjoining slabs on grade, ASD treatment of both wings provided an incremental additional radon reduction of 0 to 5.2 pCi/L, compared to ASD treatment of either one of the slabs alone. However, basement-only treatment reduced radon to <4 pCi/L in all five houses. In six basement houses having adjoining crawl spaces, ASD treatment of both wings (including sub-liner depressurization of the crawl space) provided little additional reduction compared to basement-only treatment, when sub-slab communication was good. When communication was not good, treatment of both wings was required to achieve <4 pCi/L. Tests of one fully slab-on-grade house showed that, when there is good aggregate under the slab, a one-pipe sub-slab depressurization system can achieve <1-2 pCi/L, even when there are forced-air supply ducts under the slab

  6. Evaluation of In-House and Commercial Serological Tests for Diagnosis of Human Tularemia

    Science.gov (United States)

    Yanes, Hadjila; Hennebique, Aurélie; Pelloux, Isabelle; Boisset, Sandrine; Bicout, Dominique J.; Caspar, Yvan

    2017-01-01

    ABSTRACT Tularemia is a zoonosis caused by the bacterium Francisella tularensis. Its specific diagnosis remains based on serological methods, while F. tularensis is rarely detected in clinical samples by culture or PCR. The aim of the present study was to evaluate the performance of the Serion enzyme-linked immunosorbent assay (ELISA) classic Francisella tularensis IgG and IgM tests (Virion/Serion GmbH Institute, Würzburg, Germany) and the VIRapid tularemia immunochromatographic test (ICT) (Vircell, Granada, Spain) compared to that of the in-house microagglutination test (MAT) and indirect immunofluorescence assay (IFA) currently used at the French National Reference Center for Francisella. We evaluated 256 consecutive sera from 208 patients, including 51 confirmed and 23 probable tularemia cases, and 134 control patients not infected with F. tularensis. The IFA tests displayed 72.5% sensitivity for IgM (cutoff titer ≥80) and 74.5% for IgG (cutoff titer ≥160), and 99.3% specificity for both IgM and IgG. Using cutoffs advocated by the manufacturer, the Serion ELISAs displayed 88.2% sensitivity for IgM and 86.3% for IgG antibodies; specificity was 94.8% for IgM and 95.5% for IgG. Compared to MAT and IFA tests, the Serion ELISAs allowed earlier detection of specific antibodies (1 to 2 weeks versus 2 to 3 weeks after the onset of symptoms). The ICT sensitivity and specificity were 90% and 83.6%, respectively, when considering the cutoff advocated by the manufacturer. In conclusion, the Serion ELISAs are useful as screening tests for tularemia diagnosis, but additional confirmatory tests (such as MAT and IFA) are needed, especially in areas of low endemicity. PMID:29118164

  7. The development of an Infrared Environmental System for TOPEX Solar Panel Testing

    Science.gov (United States)

    Noller, E.

    1994-01-01

    Environmental testing and flight qualification of the TOPEX/POSEIDON spacecraft solar panels were performed with infrared (IR) lamps and a control system that were newly designed and integrated. The basic goal was more rigorous testing of the costly panels' new composite-structure design without jeopardizing their safety. The technique greatly reduces the costs and high risks of testing flight solar panels.

  8. Design and test of a parallel kinematic solar tracker

    Directory of Open Access Journals (Sweden)

    Stefano Mauro

    2015-12-01

    Full Text Available This article proposes a parallel kinematic solar tracker designed for driving high-concentration photovoltaic modules. This kind of module produces energy only if they are oriented with misalignment errors lower than 0.4°. Generally, a parallel kinematic structure provides high stiffness and precision in positioning, so these features make this mechanism fit for the purpose. This article describes the work carried out to design a suitable parallel machine: an already existing architecture was chosen, and the geometrical parameters of the system were defined in order to obtain a workspace consistent with the requirements for sun tracking. Besides, an analysis of the singularities of the system was carried out. The method used for the singularity analysis revealed the existence of singularities which had not been previously identified for this kind of mechanism. From the analysis of the mechanism developed, very low nominal energy consumption and elevated stiffness were found. A small-scale prototype of the system was constructed for the first time. A control algorithm was also developed, implemented, and tested. Finally, experimental tests were carried out in order to verify the capability of the system of ensuring precise pointing. The tests have been considered passed as the system showed an orientation error lower than 0.4° during sun tracking.

  9. Active house concept versus passive House

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    The passive house concept is the present trend in energy efficient sustainable dwellings. Within the passive house concept every effort is made to minimize the energy use. Substantial savings can be achieved by passive energy systems, especially natural ventilation, summer shading and winter solar

  10. Building regulations, planning of building constructions and housing development areas taking into account the utilization of solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Bierhals, R; Schaefer, G; Weigert, D

    1977-01-01

    Complete systems for utilizing solar energy both for hot water preparation and for space heating are available in the FRG today. However, solar technology is unlikely to prevail without governmental support since the plants are still too expensive although there is a principal positive attitude towards solar energy. More knowledge of the process of solar energy utilization is necessary both in the field of building laws, and for building enterprises, architects and planners, if this new form of energy is to succeed.

  11. Experimental characterization of the thermal and solar behavior of constructed houses; Caracterizacion experimental del comportamiento termico y solar de viviendas construidas

    Energy Technology Data Exchange (ETDEWEB)

    Carrillo, A.; Jurado, L.; Molina, J. C.; Druet, L.

    2008-07-01

    Nowadays, detailed simulation models are widely used to assess thermal performance of buildings, specially during the design stage. However it is usual to report significant differences in predicted thermal performance when confronted with measured data. Therefore the model should be calibrated. In this paper, the PSTAR framework (Subbarao, 1988) is used to calibrate a Energy Plus model of a single-family dwelling. PSTAR method yields a set of renormalization coefficients that offer quantitative interpretation of the predicted vs measured differences. Other experimental tests are used to gain additional insight on how the model should be twicked judiciously. Once calibrated, the model matches three important thermal parameters of the real buildings: heat loss coefficient, thermal mass and solar gains. (Author)

  12. CMHC [Canada Mortgage and Housing Corporation] research project: Testing of air barrier construction details 2

    Energy Technology Data Exchange (ETDEWEB)

    1993-03-31

    Air leakage control through the building envelope of wood framed houses is more important than ever. This is because owners expect better temperature control, higher indoor humidity in winter, low energy consumption and building durability. The leakage of air is controlled by the air barrier system. There are several new technologies to construct an air barrier system for the building envelope. These are the Poly Approach, the Air Drywall Approach (ADA) and the EASE system. The development of these systems was undertaken primarily by the building community without significant research and development. While it is believed that these methods improve airtightness it is not known if the improvement is marginal or significant. A study was conducted to determine actual performace of several different types of construction details for each of the different approaches. Each of these details was designed and constructed using one of the air barrier methods and tested in the laboratory. The test details included sill plate, the partition wall, the stair stringer, the electrical outlets, the bathtub detail, the plumbing stack detail, the metal chimney detail, the bathroom fan detail and the EASE wall system. The test results revealed that the Poly, ADA and EASE approaches reduce air leakage by a factor of six, if applied with a modest degree of workmanship. Further, certain Poly details are to be reconsidered because they lack adequate support against design wind load pressures. 37 figs., 12 tabs.

  13. Social anthropological and interdisciplinary research on the conversion of electrically heated single family houses to heating by combined pellet-solar systems

    International Nuclear Information System (INIS)

    Henning, Annette

    2004-01-01

    The social anthropological research presented here is part of the interdisciplinary research project PESTO, which focuses on the (partial or complete) conversion of single family houses from electric heating to heating by combined pellet-solar heating systems. Basic to this research is the assumption that it is more likely that energy conversions are carried through, and that they are successful on a long-term basis, if the new products are designed to fit as well as possible into the everyday lives of people. The anthropological interest in the project can be divided into two parts; motives for or against a conversion among men and women in Swedish households, and product design and placement in (previously) electrically heated single-family houses. Literature studies and semi-structured qualitative interviews are the main methods used in the anthropological part of the project. During the next 3-year project period, these investigations will be used to support information and marketing, and to formulate recommendations for conversion practice of electrically heated single-family houses to combined pellet-solar heating. (Author)

  14. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, A.; Stecher, D.

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, Pennsylvania. Four air-based heating, ventilation, and air conditioning distribution systems--a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms--were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  15. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Stecher, Dave [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  16. Installation and testing of indoor radon reduction techniques in 40 eastern Pennsylvania houses. Final report, October 1984-June 1987

    International Nuclear Information System (INIS)

    Scott, A.G.; Robertson, A.; Findlay, W.O.

    1988-01-01

    This report discusses the installation and testing of indoor radon-reduction techniques in 40 houses in eastern Pennsylvania. Early in 1985, the Pennsylvania Department of Environmental Resources (PDER) started a large radon survey in communities in the Reading Prong (a granite formation) in eastern Pennsylvania, following the discovery of a house with extremely high radon concentrations, greater than 1.2 MBq/cu m. Candidate houses for the program, with radon concentrations in excess of 750 Bq/cu m, were selected from this survey. A total of 40 houses with representative substructure types were chosen from this group, and mitigation methods were selected and installed from June 1985 to June 1987. Initial soil-ventilation installations achieved large reductions in radon concentrations at low cost, but these reductions were not always sustained in colder weather, and several systems were modified during the project to improve their performance. Major reductions in radon concentration were realized in all the houses worked on, with most houses with active soil ventilation systems achieving less than 150 Bq/cu m (4 pCi/L) on an annual average basis in the living areas

  17. Testing of gallium arsenide solar cells on the CRRES vehicle

    International Nuclear Information System (INIS)

    Trumble, T.M.

    1985-01-01

    A flight experiment was designed to determine the optimum design for gallium arsenide (GaAs) solar cell panels in a radiation environment. Elements of the experiment design include, different coverglass material and thicknesses, welded and soldered interconnects, different solar cell efficiencies, different solar cell types, and measurement of annealing properties. This experiment is scheduled to fly on the Combined Release and Radiation Effects Satellite (CRRES). This satellite will simultaneously measure the radiation environment and provide engineering data on solar cell degradation that can be directly related to radiation damage

  18. Report on the symposium and workshop on the 5 MWt solar thermal test facility

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    Design concepts and applications for the 5 MWt Solar Thermal Test Facility at Albuquerque are discussed in 43 papers. Session topics include central receivers, solar collectors, solar energy storage, high temperature materials and chemistry. A program overview and individual contractor reports for the test facility project are included, along with reports on conference workshop sessions and users group recommendations. A list of conference attendees is appended. Separate abstracts are prepared for 39 papers.

  19. Solar-energy heats a transportation test center--Pueblo, Colorado

    Science.gov (United States)

    1981-01-01

    Petroleum-base, thermal energy transport fluid circulating through 583 square feet of flat-plate solar collectors accumulates majority of energy for space heating and domestic hot-water of large Test Center. Report describes operation, maintenance, and performance of system which is suitable for warehouses and similar buildings. For test period from February 1979 to January 1980, solar-heating fraction was 31 percent, solar hot-water fraction 79 percent.

  20. CMHC [Canadian Mortgage and Housing Corporation] research project: Testing of air barriers construction details

    Energy Technology Data Exchange (ETDEWEB)

    1991-08-26

    The airtightness of building envelopes is important in controlling comfort and energy usage in houses. Leakage generally occurs through construction details, where there are joints or connections between materials, or where there are penetrations for services or other components. A study was conducted to quantify the air leakage characteristics of three such details in wood-frame walls: the header joist, the electric outlets, and the window opening detail. Three construction methods employed to achieve airtightness were evaluated: the sealed internal membrane approach (POLY); the external air barrier approach using a continuous vapour permeable membrane sandwiched between two layers of wall sheathing(EASE); and the airtight drywall approach (ADA). Test panels containing the details were subjected to air leakage testing at pressure differentials from 50 to 1,000 pascals. Measurements of air flow were made and evidence of failure of the barrier due to pressure loading was noted. Leakage rates for the header detail with the POLY, EASE and ADA panels were 24%, 18% and 10% respectively of that for the reference panel. For the electrical outlet joint, leakage rates for POLY and EASE panels were 24% and 36%, while the ADA panel had higher leakage rates than the traditional panel. For the window detail, leakage rates were lowest for the ADA panel and similar for the POLY and EASE panels; all were less than 15% that of traditional panels. 48 figs., 2 tabs.

  1. Family Housing Metering Test. A Test Program to Determine the Feasibility of Installing Utility Meters in Military Family Housing, Developing Energy Ceilings, and Operating a Penalty Billing System for Occupants Who Overconsume Energy. Volume II. Appendices.

    Science.gov (United States)

    1980-03-01

    implementation. 5.2 NORM PAMPHLET The norm pamphlet is a short, picture-oriented brochure to introduce military housing occupants to the use of the energy...tne final version of the pamplet , feedbaci roejrdiag the. draf t version sill be solicited from the fiefl test par- ticipants. rhe followlag is a rouga

  2. Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing

    International Nuclear Information System (INIS)

    Cuce, Erdem; Cuce, Pinar Mert; Young, Chin-Huai

    2016-01-01

    HISG (heat insulation solar glass) is a recently developed multi-functional glazing technology to mitigate energy consumption of buildings. HISG can generate electricity similar to conventional PV (photovoltaic) glazing products when exposed to sunlight, however it differs from them by having some extraordinary characteristic features such as thermal insulation, which is competitive with Argon filled triple glazed windows, acoustic comfort, remarkable energy saving potential and self-cleaning ability owing to TiO_2 nano coating. Within the scope of this research, latest results from laboratory and in-situ testing of HISG are presented in terms of its key role in mitigating heating and cooling demand of buildings as well as clean energy generation. Lighting and thermal comfort related parameters such as shading coefficient, UV, IR and visible light intensity are also investigated through the tests conducted in real operating conditions. It is achieved from the results that instant electricity generation of HISG is 16% higher than that of standard PV glazing owing to its nano layer reflective film. Shading coefficient of HISG is only 0.136, which provides almost 80% reduction in solar heat gain compared to ordinary glazing. Indoor air temperature measured from HISG test house in summer time is very close to the ambient temperature, whereas it is found to be 14.7 °C higher in ordinary glass test house due to greenhouse effect. Annual heating and cooling demand tests indicate that HISG provides 38 and 48% energy saving in heating and cooling season, respectively. - Highlights: • Nano layer reflective film of HISG enables 16% more power generation. • 80% of undesired outdoor thermal radiation is prevented by HISG. • HISG has a 100% UV blocking rate. • The shading coefficient of HISG is 0.136. • HISG provides 38 and 48% energy saving in heating and cooling season.

  3. Inventory of existing heat pump projects and the use of solar energy for heat pumps in the Dutch house construction sector

    International Nuclear Information System (INIS)

    1997-01-01

    The aim of the title inventory is to learn from the experiences with heat pump projects in the Netherlands. Descriptions are given of practical experiences with heat pump applications in the last 15 years in the housing sector. Possible and feasible heat pump system concepts are analyzed and energy balances and energy consumption are calculated. Special attention is paid to the use of solar energy in combination with electric (compression) heat pumps. One of the most important bottlenecks is the method and availability of heat extraction: the choice for the different options is determined by investment costs, permission, regulations, and local conditions. 14 refs., 4 appendices

  4. TESTING THE EFFECTS OF EXPANSION ON SOLAR WIND TURBULENCE

    International Nuclear Information System (INIS)

    Vech, Daniel; Chen, Christopher H K

    2016-01-01

    We present a multi-spacecraft approach to test the predictions of recent studies on the effect of solar wind expansion on the radial spectral, variance, and local 3D anisotropies of the turbulence. We found that on small scales (5000–10,000 km) the power levels of the B-trace structure functions do not depend on the sampling direction with respect to the radial suggesting that on this scale the effect of expansion is small possibly due to fast turbulent timescales. On larger scales (110–135 R E ), the fluctuations of the radial magnetic field component are reduced by ∼20% compared to the transverse (perpendicular to radial) ones, which could be due to expansion confining the fluctuations into the plane perpendicular to radial. For the local 3D spectral anisotropy, the B-trace structure functions showed dependence on the sampling direction with respect to radial. The anisotropy in the perpendicular plane is reduced when the increments are taken perpendicular with respect to radial, which could be an effect of expansion.

  5. TESTING THE EFFECTS OF EXPANSION ON SOLAR WIND TURBULENCE

    Energy Technology Data Exchange (ETDEWEB)

    Vech, Daniel; Chen, Christopher H K, E-mail: dvech@umich.edu [Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom)

    2016-11-20

    We present a multi-spacecraft approach to test the predictions of recent studies on the effect of solar wind expansion on the radial spectral, variance, and local 3D anisotropies of the turbulence. We found that on small scales (5000–10,000 km) the power levels of the B-trace structure functions do not depend on the sampling direction with respect to the radial suggesting that on this scale the effect of expansion is small possibly due to fast turbulent timescales. On larger scales (110–135 R{sub E}), the fluctuations of the radial magnetic field component are reduced by ∼20% compared to the transverse (perpendicular to radial) ones, which could be due to expansion confining the fluctuations into the plane perpendicular to radial. For the local 3D spectral anisotropy, the B-trace structure functions showed dependence on the sampling direction with respect to radial. The anisotropy in the perpendicular plane is reduced when the increments are taken perpendicular with respect to radial, which could be an effect of expansion.

  6. Convergence of metropolitan house prices in South Africa: a re-examination using efficient unit root tests

    CSIR Research Space (South Africa)

    Das, Sonali

    2010-01-01

    Full Text Available This paper analyzes whether the Law of One Price (LOOP) holds in the housing market of five metropolitan areas of South Africa, namely Cape Town, Durban, Greater Johannesburg, Port Elizabeth/Uitenhage and Pretoria. The authors test the existence...

  7. Y chromosomal and sex effects on the behavioral stress response in the defensive burying test in wild house mice

    NARCIS (Netherlands)

    Sluyter, F; Korte, SM; Van Baal, GCM; De Ruiter, AJH; Van Oortmerssen, GA

    1999-01-01

    Genetically selected short attack latency (SAL) and long attack latency (LAL) male wild house mice behave differently in the defensive burying test. When challenged, SAL males respond actively with more time spent on defensive burying, whereas LAL males are more passive with more time remaining

  8. Assessment Of The Viability Of Kaduna City Climate For Year Round Use Of Direct Solar Thermal Cooking Fuel In Housing

    Directory of Open Access Journals (Sweden)

    Boumann Ephraim Sule

    2017-10-01

    Full Text Available Solar energy obtained from the sun is the world most abundant and cheapest source of energy as a cooking fuel. It comes in two forms Concentrated Solar Thermal direct conversion of solar energy to heat that cooks and Solar Photovoltaic PV a conversion of solar energy to electrical then to heat energy the former technology is simple and far cheaper. Despite all these architectural and engineering researches is yet to capture it for indoor cooking because of inability to cook year round due the claimed hindrances by weather condition such as clouds rainfall wind dusty atmosphere and many others. This paper attempted to look into the possibility of cooking year round in Kaduna city. It collected and analyzed ten years climatic data from three different meteorological stations strategically located round the city this showed a low solar radiation in the month of August. It further compared the result with a literature review of solar cooking carried in the same month the findings showed at the peak of each weather hindrance a another element overrides it to give enough minimum energy for cooking a meals. This paper has therefore pointed the potentials of Kaduna city climate for year round use of concentrated solar thermal as a cooking fuel in residential building and further recommends the architectural collaboration with engineers for the direct capturing of solar rays into residential dwelling as a sustainable cooking fuel.

  9. Test bench HEATREC for heat loss measurement on solar receiver tubes

    Science.gov (United States)

    Márquez, José M.; López-Martín, Rafael; Valenzuela, Loreto; Zarza, Eduardo

    2016-05-01

    In Solar Thermal Electricity (STE) plants the thermal energy of solar radiation is absorbed by solar receiver tubes (HCEs) and it is transferred to a heat transfer fluid. Therefore, heat losses of receiver tubes have a direct influence on STE plants efficiency. A new test bench called HEATREC has been developed by Plataforma Solar de Almería (PSA) in order to determinate the heat losses of receiver tubes under laboratory conditions. The innovation of this test bench consists in the possibility to determine heat losses under controlled vacuum.

  10. Hood River Passive House

    Energy Technology Data Exchange (ETDEWEB)

    Hales, David [BA-PIRC, Spokane, WA (United States)

    2014-01-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

  11. The ACTH4–9 analog ORG 2766 ‘normalizes’ the changes in motor activities of rats elicited by housing and test conditions

    NARCIS (Netherlands)

    Wolterink, G.; Ree, J.M. van

    1987-01-01

    Motor activities of rats were decreased by short-term (7 days) social isolation as well as by intense light test conditions. The ACTH4-9 analog ORG 2766, s.c. administered 50 min before testing, dose-dependently decreased the high motor activities of group-housed housed rats tested under low light

  12. AXAF-I Low Intensity-Low Temperature (LILT) Testing of the Development Verification Test (DVT) Solar Panel

    Science.gov (United States)

    Alexander, Doug; Edge, Ted; Willowby, Doug

    1998-01-01

    The planned orbit of the AXAF-I spacecraft will subject the spacecraft to both short, less than 30 minutes for solar and less than 2 hours for lunar, and long earth eclipses and lunar eclipses with combined conjunctive duration of up to 3 to 4 hours. Lack of proper Electrical Power System (EPS) conditioning prior to eclipse may cause loss of mission. To avoid this problem, for short eclipses, it is necessary to off-point the solar array prior to or at the beginning of the eclipse to reduce the battery state of charge (SOC). This yields less overcharge during the high charge currents at sun entry. For long lunar eclipses, solar array pointing and load scheduling must be tailored for the profile of the eclipse. The battery SOC, loads, and solar array current-voltage (I-V) must be known or predictable to maintain the bus voltage within acceptable range. To address engineering concerns about the electrical performance of the AXAF-I solar array under Low Intensity and Low Temperature (LILT) conditions, Marshall Space Flight Center (MSFC) engineers undertook special testing of the AXAF-I Development Verification Test (DVT) solar panel in September-November 1997. In the test the DVT test panel was installed in a thermal vacuum chamber with a large view window with a mechanical "flapper door". The DVT test panel was "flash" tested with a Large Area Pulse Solar Simulator (LAPSS) at various fractional sun intensities and panel (solar cell) temperatures. The testing was unique with regards to the large size of the test article and type of testing performed. The test setup, results, and lessons learned from the testing will be presented.

  13. Task assignment No. 3. Solar audience test summary report. [Reactions of viewers to public service advertisements about solar energy

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-03

    Audience response to a public service advertisement concerning solar energy was tested. The test was designed to answer four categories of questions: (1) what information on solar energy in general is conveyed by the advertisement. What additional information is desired; (2) what is the reaction of the respondent to specific components or characteristics of the advertisment; (3) how appropriate is the use of the American Indian in conveying the message; and (4) how likely is the respondent to take further action as a result of viewing the advertisment. The rationale and methods for answering each question are discussed. (LEW)

  14. Initial Test Bed for Very High Efficiency Solar Cells

    Science.gov (United States)

    2008-05-01

    efficiency, both at the solar cell and module levels. The optical system consists of a tiled nonimaging concentrating system, coupled with a spectral...To achieve the benefits of the new photovoltaic system architecture, a new optical element is designed that combines a nonimaging optical...of the power from each solar cell. Optics Design The most advanced optical design is based on non- symmetric, nonimaging optics, tiled into an

  15. Tech House

    Science.gov (United States)

    1978-01-01

    The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, loatedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

  16. House dust bioactivities predict skin prick test reactivity for children with high risk of allergy.

    Science.gov (United States)

    Kim, Haejin; Tse, Kevin; Levin, Linda; Bernstein, David; Reponen, Tiina; LeMasters, Grace; Lummus, Zana; Horner, Anthony A

    2012-06-01

    Although evidence suggests that ambient exposures to endotoxin and other immunostimulants during early life influence allergic risk, efforts to understand this host-environment relationship have been hampered by a paucity of relevant assays. These investigations determined whether parameters of house dust extract (HDE) bioactivity were predictive of allergen skin prick test (SPT) reactivity for infants at high risk of allergy participating in the Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS). We conducted a nested case-control study, selecting 99 CCAAPS children who had positive SPT results to at least 1 aeroallergen at age 3 years and 101 subjects with negative SPT results. HDEs were prepared from dust samples collected from the subjects' homes at age 1 year. Murine splenocytes and bone marrow-derived dendritic cells were incubated with HDEs, and supernatant cytokine concentrations were determined by means of ELISA. Alternatively, bone marrow-derived dendritic cells were preincubated with HDEs, and then LPS-induced IL-6 responses were assessed. HDE endotoxin levels were determined by using the limulus amebocyte lysate assay. HDEs derived from the homes of children with positive (cases) and negative (control subjects) SPT results had similar bioactivities. However, when cases were considered in isolation, HDEs with higher levels of bioactivity were significantly associated with children who had lower numbers of positive SPT results. Analogous statistical analyses did not identify any association between HDE endotoxin levels and the aeroallergen sensitization profiles of children included in this study. HDE immunostimulatory activities predicted the aeroallergen sensitization status of CCAAPS subjects better than HDE endotoxin levels. These results provide the first published evidence that HDE bioassays have clinical relevance in predicting atopic risk. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All

  17. MINIPILOT SOLAR SYSTEM: DESIGN/OPERATION OF SYSTEM AND RESULTS OF NON-SOLAR TESTING AT MRI

    Science.gov (United States)

    Prior to this project, MRI had carried out work for the Environmental Protection Agency (EPA) on the conceptual design of a solar system for solid waste disposal and a follow-on project to study the feasibility of bench-scale testing of desorption of organics from soil with destr...

  18. Investigation of the comparative test method of solar DHW system; Solar kyuto system no toitsuteki seino shiken hoho no chosa

    Energy Technology Data Exchange (ETDEWEB)

    Oishi, M; Noguchi, T [Japan Quality Assurance Organization, Tokyo (Japan)

    1996-10-27

    For the development of a unified performance test method for solar DHW (domestic hot water) systems, the Japan Quality Assurance Organization test was applied to three types. In an individual test, each specimen is exposed to irradiation from a solar simulator for 8 hours in a specified pattern. Upon completion of the 8-hour irradiation, hot water is taken from the specimen, the amount being 1.1 times as large as the heat accumulation tank capacity, for the measurement of the collected heat. The control of the heat medium circulation pump, flow rate, and density, all supposed to affect the heat collecting performance, are examined. Stable data, not subject to meteorological factors and high in reproducibility, is obtained, allowing a single test to represent the heat collecting performance. A system test continues for 24 hours, from 8 o`clock on this morning through 8 o`clock on the following morning, with water collected in a specified pattern. This test is suitable for examining the in-service performance of a solar hot water system including the auxiliary heat source. If temperature is not set properly in the auxiliary heat source before testing, the system performance coefficient and sun-dependency coefficient will not be expressed in a uniform manner. For a correct evaluation, measurements should be made only after a several days` uninterrupted operation for the removal of the adverse effect of the heat residual in the heat accumulation tank. 4 refs., 5 figs., 9 tabs.

  19. Electrostatic Discharge Test of Multi-Junction Solar Array Coupons After Combined Space Environmental Exposures

    Science.gov (United States)

    Wright, Kenneth H.; Schneider, Todd; Vaughn, Jason; Hoang, Bao; Funderburk, Victor V.; Wong, Frankie; Gardiner, George

    2010-01-01

    A set of multi-junction GaAs/Ge solar array test coupons were subjected to a sequence of 5-year increments of combined environmental exposure tests. The test coupons capture an integrated design intended for use in a geosynchronous (GEO) space environment. A key component of this test campaign is conducting electrostatic discharge (ESD) tests in the inverted gradient mode. The protocol of the ESD tests is based on the ISO/CD 11221, the ISO standard for ESD testing on solar array panels. This standard is currently in its final review with expected approval in 2010. The test schematic in the ISO reference has been modified with Space System/Loral designed circuitry to better simulate the on-orbit operational conditions of its solar array design. Part of the modified circuitry is to simulate a solar array panel coverglass flashover discharge. All solar array coupons used in the test campaign consist of 4 cells. The ESD tests are performed at the beginning of life (BOL) and at each 5-year environment exposure point. The environmental exposure sequence consists of UV radiation, electron/proton particle radiation, thermal cycling, and ion thruster plume. This paper discusses the coverglass flashover simulation, ESD test setup, and the importance of the electrical test design in simulating the on-orbit operational conditions. Results from 5th-year testing are compared to the baseline ESD characteristics determined at the BOL condition.

  20. Solar Alpha Rotary Joint (SARJ) Lubrication Interval Test and Evaluation (LITE). Post-Test Grease Analysis

    Science.gov (United States)

    Golden, Johnny L.; Martinez, James E.; Devivar, Rodrigo V.

    2015-01-01

    The Solar Alpha Rotary Joint (SARJ) is a mechanism of the International Space Station (ISS) that orients the solar power generating arrays toward the sun as the ISS orbits our planet. The orientation with the sun must be maintained to fully charge the ISS batteries and maintain all the other ISS electrical systems operating properly. In 2007, just a few months after full deployment, the starboard SARJ developed anomalies that warranted a full investigation including ISS Extravehicular Activity (EVA). The EVA uncovered unexpected debris that was due to degradation of a nitride layer on the SARJ bearing race. ISS personnel identified the failure root-cause and applied an aerospace grease to lubricate the area associated with the anomaly. The corrective action allowed the starboard SARJ to continue operating within the specified engineering parameters. The SARJ LITE (Lubrication Interval Test and Evaluation) program was initiated by NASA, Lockheed Martin, and Boeing to simulate the operation of the ISS SARJ for an extended time. The hardware was designed to test and evaluate the exact material components used aboard the ISS SARJ, but in a controlled area where engineers could continuously monitor the performance. After running the SARJ LITE test for an equivalent of 36+ years of continuous use, the test was opened to evaluate the metallography and lubrication. We have sampled the SARJ LITE rollers and plate to fully assess the grease used for lubrication. Chemical and thermal analysis of these samples has generated information that has allowed us to assess the location, migration, and current condition of the grease. The collective information will be key toward understanding and circumventing any performance deviations involving the ISS SARJ in the years to come.

  1. Cooling with solar energy - Tests in practice passed

    International Nuclear Information System (INIS)

    Lainsecq de, M.

    2004-01-01

    This article discusses the use of solar energy to provide summer cooling. Starting with centuries-old methods of adiabatic cooling used in the southern valleys of the Grisons in Switzerland, various methods of using solar energy to generate cold are examined. The article mentions the increasing load being placed on electricity supplies by conventional cooling systems and describes two real-life installations that use solar energy to generate cold. The first installation described uses evacuated tube collectors to provide around 45,000 kilowatt-hours of energy for an office complex, of which one third is used in summer to generate cold. The second installation features flat-plate collectors and two absorption refrigeration machines. Financial and environmental balances are presented and discussed

  2. 25 solar houses single-family of promotion publishes in Cantimpalos (Segovia); 25 viviendas unifamilares solares de promocion publica en Cantimpalos (Segovia)

    Energy Technology Data Exchange (ETDEWEB)

    Yanez, G.

    2008-07-01

    We present in this article a set of social houses built in Sevogia for the Autonomous Administration of Castilla y Leon in which have been applied some bio climatic and passive techniques. In this communication are described the main architectural features and are exposed the energy saving calculated and some of the results obtained through monitoring. (Author)

  3. Development and testing of an implementation strategy for a complex housing intervention: protocol for a mixed methods study.

    Science.gov (United States)

    Watson, Dennis P; Young, Jeani; Ahonen, Emily; Xu, Huiping; Henderson, Macey; Shuman, Valery; Tolliver, Randi

    2014-10-17

    There is currently a lack of scientifically designed and tested implementation strategies. Such strategies are particularly important for highly complex interventions that require coordination between multiple parts to be successful. This paper presents a protocol for the development and testing of an implementation strategy for a complex intervention known as the Housing First model (HFM). Housing First is an evidence-based practice for chronically homeless individuals demonstrated to significantly improve a number of outcomes. Drawing on practices demonstrated to be useful in implementation and e-learning theory, our team is currently adapting a face-to-face implementation strategy so that it can be delivered over a distance. Research activities will be divided between Chicago and Central Indiana, two areas with significantly different barriers to HFM implementation. Ten housing providers (five from Chicago and five from Indiana) will be recruited to conduct an alpha test of each of four e-learning modules as they are developed. Providers will be requested to keep a detailed log of their experience completing the modules and participate in one of two focus groups. After refining the modules based on alpha test results, we will test the strategy among a sample of four housing organizations (two from Chicago and two from Indiana). We will collect and analyze both qualitative and quantitative data from administration and staff. Measures of interest include causal factors affecting implementation, training outcomes, and implementation outcomes. This project is an important first step in the development of an evidence-based implementation strategy to increase scalability and impact of the HFM. The project also has strong potential to increase limited scientific knowledge regarding implementation strategies in general.

  4. Invited article: Electric solar wind sail: toward test missions.

    Science.gov (United States)

    Janhunen, P; Toivanen, P K; Polkko, J; Merikallio, S; Salminen, P; Haeggström, E; Seppänen, H; Kurppa, R; Ukkonen, J; Kiprich, S; Thornell, G; Kratz, H; Richter, L; Krömer, O; Rosta, R; Noorma, M; Envall, J; Lätt, S; Mengali, G; Quarta, A A; Koivisto, H; Tarvainen, O; Kalvas, T; Kauppinen, J; Nuottajärvi, A; Obraztsov, A

    2010-11-01

    The electric solar wind sail (E-sail) is a space propulsion concept that uses the natural solar wind dynamic pressure for producing spacecraft thrust. In its baseline form, the E-sail consists of a number of long, thin, conducting, and centrifugally stretched tethers, which are kept in a high positive potential by an onboard electron gun. The concept gains its efficiency from the fact that the effective sail area, i.e., the potential structure of the tethers, can be millions of times larger than the physical area of the thin tethers wires, which offsets the fact that the dynamic pressure of the solar wind is very weak. Indeed, according to the most recent published estimates, an E-sail of 1 N thrust and 100 kg mass could be built in the rather near future, providing a revolutionary level of propulsive performance (specific acceleration) for travel in the solar system. Here we give a review of the ongoing technical development work of the E-sail, covering tether construction, overall mechanical design alternatives, guidance and navigation strategies, and dynamical and orbital simulations.

  5. Central Control of Heat Pump for Smart Grid Purposes Tested on Single Family Houses

    DEFF Research Database (Denmark)

    Pedersen, Tom S.; Andersen, Palle; Nielsen, Kirsten M.

    2013-01-01

    A challenge in Denmark in the near future is to balance the electrical grid due to a large increase in the renewable energy production mainly from wind turbines. In this work a central control system using heat pumps in single family houses to help balancing the grid is investigated. The central...

  6. Modeling of a Parabolic Trough Solar Field for Acceptance Testing: A Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M. J.; Mehos, M. S.; Kearney, D. W.; McMahan, A. C.

    2011-01-01

    As deployment of parabolic trough concentrating solar power (CSP) systems ramps up, the need for reliable and robust performance acceptance test guidelines for the solar field is also amplified. Project owners and/or EPC contractors often require extensive solar field performance testing as part of the plant commissioning process in order to ensure that actual solar field performance satisfies both technical specifications and performance guaranties between the involved parties. Performance test code work is currently underway at the National Renewable Energy Laboratory (NREL) in collaboration with the SolarPACES Task-I activity, and within the ASME PTC-52 committee. One important aspect of acceptance testing is the selection of a robust technology performance model. NREL1 has developed a detailed parabolic trough performance model within the SAM software tool. This model is capable of predicting solar field, sub-system, and component performance. It has further been modified for this work to support calculation at subhourly time steps. This paper presents the methodology and results of a case study comparing actual performance data for a parabolic trough solar field to the predicted results using the modified SAM trough model. Due to data limitations, the methodology is applied to a single collector loop, though it applies to larger subfields and entire solar fields. Special consideration is provided for the model formulation, improvements to the model formulation based on comparison with the collected data, and uncertainty associated with the measured data. Additionally, this paper identifies modeling considerations that are of particular importance in the solar field acceptance testing process and uses the model to provide preliminary recommendations regarding acceptable steady-state testing conditions at the single-loop level.

  7. Wind Tunnel Tests of Parabolic Trough Solar Collectors: March 2001--August 2003

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, N.; Peterka, J. A.; Gee, R. C.; Kearney, D.

    2008-05-01

    Conducted extensive wind-tunnel tests on parabolic trough solar collectors to determine practical wind loads applicable to structural design for stress and deformation, and local component design for concentrator reflectors.

  8. Standardized performance tests of collectors of solar thermal energy: Prototype moderately concentrating grooved collectors

    Science.gov (United States)

    1976-01-01

    Prototypes of moderately concentrating grooved collectors were tested with a solar simulator for varying inlet temperature, flux level, and incident angle. Collector performance is correlated in terms of inlet temperature and flux level.

  9. Solar Schematic

    Science.gov (United States)

    1979-01-01

    The home shown at right is specially designed to accommodate solar heating units; it has roof planes in four directions, allowing placement of solar collectors for best exposure to the sun. Plans (bottom) and complete working blueprints for the solar-heated house are being marketed by Home Building Plan Service, Portland, Oregon. The company also offers an inexpensive schematic (center) showing how a homeowner only moderately skilled in the use of tools can build his own solar energy system, applicable to new or existing structures. The schematic is based upon the design of a low-cost solar home heating system built and tested by NASA's Langley Research Center; used to supplement a warm-air heating system, it can save the homeowner about 40 percent of his annual heating bill for a modest investment in materials and components. Home Building Plan Service saved considerable research time by obtaining a NASA technical report which details the Langley work. The resulting schematic includes construction plans and simplified explanations of solar heat collection, collectors and other components, passive heat factors, domestic hot water supply and how to work with local heating engineers.

  10. Solar cooker effect test and temperature field simulation of radio telescope subreflector

    International Nuclear Information System (INIS)

    Chen, Deshen; Wang, Huajie; Qian, Hongliang; Zhang, Gang; Shen, Shizhao

    2016-01-01

    Highlights: • Solar cooker effect test of a telescope subreflector is conducted for the first time. • The cause and temperature distribution regularities are analyzed contrastively. • Simulation methods are proposed using light beam segmentation and tracking methods. • The validity of simulation methods is evaluated using the test results. - Abstract: The solar cooker effect can cause a local high temperature of the subreflector and can directly affect the working performance of the radio telescope. To study the daily temperature field and solar cooker effect of a subreflector, experimental studies are carried out with a 3-m-diameter radio telescope model for the first time. Initially, the solar temperature distribution rules, especially the solar cooker effect, are summarized according to the field test results under the most unfavorable conditions. Then, a numerical simulation for the solar temperature field of the subreflector is studied by light beam segmentation and tracking methods. Finally, the validity of the simulation methods is evaluated using the test results. The experimental studies prove that the solar cooker effect really exists and should not be overlooked. In addition, simulation methods for the subreflector temperature field proposed in this paper are effective. The research methods and conclusions can provide valuable references for thermal design, monitoring and control of similar high-precision radio telescopes.

  11. Space Environmental Effects Testing and Characterization of the Candidate Solar Sail Material Aluminized Mylar

    Science.gov (United States)

    Edwards, D. L.; Hubbs, W. S.; Wertz, G. E.; Alstatt, R.; Munafo, Paul (Technical Monitor)

    2001-01-01

    The usage of solar sails as a propellantless propulsion system has been proposed for many years. The technical challenges associated with solar sails are fabrication of ultralightweight films, deploying the sails and controlling the spacecraft. Integral to all these challenges is the mechanical property integrity of the sail while exposed to the harsh environment of space. This paper describes testing and characterization of a candidate solar sail material, Aluminized Mylar. This material was exposed to a simulated Geosynchronous Transfer Orbit (GTO) and evaluated by measuring thermooptical and mechanical property changes. Testing procedures and results are presented.

  12. Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain

    Science.gov (United States)

    2015-12-01

    determined that shielding the screen from solar gains was the best way to avoid monitor failure. In order to accomplish this Hot Mirror glass from...side of the monitor in order to shield the monitor from the solar loading. 2.7 Test 7 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass , 1 Inch...method to shield the screen from solar loading. The Hot Mirror glass uses a glass substrate with a coating on 1 side that passes visible light, but

  13. Degradation of Solar Array Components in a Combined UV/VUV High Temperature Test Environment

    Directory of Open Access Journals (Sweden)

    Nömayr Christel

    2017-01-01

    A design verification test under UV/VUV conditions of sun exposed materials and technologies on component level is presented which forms part of the overall verification and qualification of the solar array design of the MTM and MPO. The test concentrates on the self-contamination aspects and the resulting performance losses of the solar array under high intensity and elevated temperature environment representative for the photovoltaic assembly (PVA.

  14. A Solar Axion Search Using a Decommissioned LHC Test Magnet

    CERN Multimedia

    Lozza, V; Christensen, F E; Jakobsen, A C; Neff, S H; Carmona martinez, J M; Giomataris, I; Krcmar, M; Vafeiadis, T; Luzon marco, G M; Gracia garza, J; Lakic, B; Cantatore, G; Solanki, S K; Ozbey, A; Davenport, M; Funk, W; Desch, K K; Villar, J A; Jakovcic, K; Eleftheriadis, C; Diago ortega, A; Zioutas, K; Gardikiotis, A; Cetin, S A; Hasinoff, M D; Hoffmann, D; Laurent, J; Castel pablo, J F; Gninenko, S; Ferrer ribas, E; Liolios, A; Anastasopoulos, V; Kaminski, J; Dafni, T; Garcia irastorza, I; Ruiz choliz, E; Pivovaroff, M J; Krieger, C; Lutz, G; Fanourakis, G; Ruz armendariz, J; Vogel, J K

    2002-01-01

    Previous solar axion searches have been carried out in Brookhaven (1990) and in Tokyo (2000- ), tracking the Sun with a dipole magnet. QCD inspired axions should be produced after the Big Bang, being thus candidates for the dark matter. The Sun is a very useful source of weakly interacting particles for fundamental research. Axions can be produced also in the Sun's core through the scattering of thermal photons in the Coulomb field of electric charges (Primakoff effect). In a transverse magnetic field the Primakoff effect can work in reverse, coherently converting the solar axions or other axion-like particles (ALPS) back into X-ray photons in the keV range. The conversion efficiency increases with $(B⋅L)^2$. In the CAST experiment an LHC prototype dipole magnet (B = 9 T and L = 10 m) with straight beam pipes provides a conversion efficiency exceeding that of the two earlier solar axion telescopes by almost a factor of 100. This magnet is mounted on a moving platform and coupled to both gas filled and soli...

  15. Differential testosterone secretory capacity of the testes of aggressive and nonaggressive house mice during ontogeny

    OpenAIRE

    de Ruiter, Anne J H; Koolhaas, Jaap M; van Oortmerssen, Geert A; Bohus, Bela

    1992-01-01

    In this study, testosterone secretory capacity of testicular Leydig cells during ontogeny was determined in males of an aggressive and a nonaggressive genetic selection line of wild house mice. Neonates, 23-day-old prepubertals, and adult male mice were studied. A morphometric method was used to quantify 3-beta-hydroxy steroid dehydrogenase (3-beta-HSD)-stained Leydig cells in testicular sections to determine testosterone secretory capacity. We consider this parameter to reflect circulating t...

  16. Conditional Tests of Factor Augmented Asset Pricing Models with Human Capital and Housing: Some New Results

    OpenAIRE

    Olga Klinkowska

    2009-01-01

    In this paper I develop the asset pricing model in which the wealth portfolio is enriched with human capital and housing capital. These two types of capital account for a significant portion of the total wealth. Additionally I introduce dynamics into the model and represent conditioning information by common factors estimated with dynamic factor methodology. In this way I can use more accurate representative of the unobservable information set of the investors. Obtained results prove that ind...

  17. Development and testing of mini heat pump for low-energy houses. Final report; Udvikling og test af minivarmepumpe til lavenergihuse. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Per Henrik; Madsen, Claus; Frederiksen, Klaus; Andreasen, Marcin Blazniak (Teknologisk Institut, Koele- og Varmepumpeteknik, Taastrup (Denmark))

    2010-11-15

    New residential houses are better insulated, and this reduces the need for heat during the winter period. In addition to this many new houses have floor heating systems. This combination is favourable for small heat pumps which can produce heat to central water systems with low water temperatures in the area 25 to 35 C. 4 prototypes of mini heat pumps of the brine/water type was build and tested in the refrigeration laboratory at the Danish Technological Institute (DTI). The prototypes are using a variable speed compressor (Danfoss SLV12) which originally is developed for plug-in supermarket cabinets. The heating capacity of the prototypes can vary between 1.0 and 2.1 kW. The refrigerant charge is 150 grams of R290 (propane). Two prototypes are charged with 375 grams of R134a. Tests were conducted following EN14511 at 0/+35 C and COP was measured to between 3.2 and 3.6 depending of the compressor speed and the type of plate heat exchangers used. This is quite good for such small machines. One of the prototypes was installed in the Energy Flex House which is a new highly insulated test house build at the DTI. The house was equipped with two heat pumps: 1. An exhaust air heat pump taking energy from exhaust air and producing hot tap water and heating the intake air; 2. A mini heat pump for floor heating taking energy from ground source outside the house. A family with four persons lives in the house. During the cold winter 2009/2010 the mini heat pump showed good performance and the COP varies between 2.0 and 4.0. The lower value was caused by a fault in the floor heating hoses, which made it necessary to increase the temperature of the central heating water, which decreased the efficiency of the heat pump during the coldest winter period. The floor heating system has been repaired, and a new prototype heat pump with a slightly bigger compressor has been installed for the heating season 2010/2011. A heat pump manufacturer is now producing this combination of exhaust

  18. Laboratory Testing of Solar Combi System with Compact Long Term PCM Heat Storage

    DEFF Research Database (Denmark)

    Johansen, Jakob Berg; Englmair, Gerald; Dannemand, Mark

    2016-01-01

    To enable the transition from fossil fuels as a primary heat source for domestic hot water preparation and space heating solar thermal energy has great potential. The heat from the sun has the disadvantage that it is not always available when there is a demand. To solve this mismatch a thermal...... seasonal storage can be used to store excess heat from the summer to the winter when the demand is higher than the supply. Installing a long term thermal storage in a one family house it needs to be compact and sensible heat storages are not suitable. A latent heat storage with a phase change material (PCM...

  19. Testing of indoor radon-reduction techniques in central Ohio houses: Phase 1 (Winter 1987-1988). Report for October 1987-August 1988 (Final)

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1989-07-01

    The U.S. Environmental Protection Agency (EPA) has a program to demonstrate practical, cost-effective methods to reduce indoor radon concentrations in housing to 150 Bq/cu m (4 pCi/L) or less. The complete program will evaluate the full range of radon-reduction methods, i.e., house ventilation, sealing of entry routes, soil ventilation, radon removal from water, and air cleaning in the full range of housing substructure types and building styles, and geological conditions across the continental United States. The program described in the report demonstrated certain radon-reduction methods in housing and geology typical of southern Ohio in particular, and the central Great Plains States in general. The testing of radon-mitigation systems in Ohio houses is envisioned as taking place in two phases. The report describes Phase 1, which was carried out in 16 existing houses in the Dayton area during the 1987-1988 heating season

  20. Mercury Conditions for the MESSENGER Mission Simulated in High- Solar-Radiation Vacuum Tests

    Science.gov (United States)

    Wong, Wayne A.

    2003-01-01

    The MESSENGER (Mercury Surface, Space Environment, Geochemistry, and Ranging) spacecraft, planned for launch in March 2004, will perform two flybys of Mercury before entering a year-long orbit of the planet in September 2009. The mission will provide opportunities for detailed characterization of the surface, interior, atmosphere, and magnetosphere of the closest planet to the Sun. The NASA Glenn Research Center and the MESSENGER spacecraft integrator, the Johns Hopkins University Applied Physics Laboratory, have partnered under a Space Act Agreement to characterize a variety of critical components and materials under simulated conditions expected near Mercury. Glenn's Vacuum Facility 6, which is equipped with a solar simulator, can simulate the vacuum and high solar radiation anticipated in Mercury orbit. The MESSENGER test hardware includes a variety of materials and components that are being characterized during the Tank 6 vacuum tests, where the hardware will be exposed to up to 11 suns insolation, simulating conditions expected in Mercury orbit. In 2002, ten solar vacuum tests were conducted, including beginning of life, end of life, backside exposure, and solar panel thermal shock cycling tests. Components tested include candidate solar array panels, sensors, thermal shielding materials, and communication devices. As an example, for the solar panel thermal shock cycling test, two candidate solar array panels were suspended on a lift mechanism that lowered the panels into a liquid-nitrogen-cooled box. After reaching -140 C, the panels were then lifted out of the box and exposed to the equivalent of 6 suns (8.1 kilowatts per square meters). After five cold soak/heating cycles were completed successfully, there was no apparent degradation in panel performance. An anticipated 100-hr thermal shield life test is planned for autumn, followed by solar panel flight qualification tests in winter. Glenn's ongoing support to the MESSENGER program has been instrumental in

  1. Good planning for maximum efficiency. Part 1. Housing development of passive buildings with solar district heat supply; Sauber geplant is halb gewonnen. Teil 1. Passivhaussiedlung mit solarer Nahwaermeversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Meissner, R. [Ritter Energie- und Umwelttechnik, Karlsbad (Germany)

    2003-06-01

    A new development of 12 single-family dwellings was constructed with complex technical facilities and many innovative elements by Gewerbepark Ritter and Messrs. Paradigma, a provider of thermal solar systems. [German] Der Gewerbepark Ritter und die auf thermische Solarindustrie spezialisierte Firma Paradigma haben bei der Errichtung einer Siedlung mit 12 Einfamilienhaeusern mit einem komplexen Haustechnikkonzept ein wegweisendes Projekt mit vielen innovativen Neuerungen erfolgreich in die Tat umgesetzt. (orig.)

  2. The Xenon Test Chamber Q-SUN® for testing realistic tolerances of fungi exposed to simulated full spectrum solar radiation.

    Science.gov (United States)

    Dias, Luciana P; Araújo, Claudinéia A S; Pupin, Breno; Ferreira, Paulo C; Braga, Gilberto Ú L; Rangel, Drauzio E N

    2018-06-01

    The low survival of insect-pathogenic fungi when used for insect control in agriculture is mainly due to the deleterious effects of ultraviolet radiation and heat from solar irradiation. In this study, conidia of 15 species of entomopathogenic fungi were exposed to simulated full-spectrum solar radiation emitted by a Xenon Test Chamber Q-SUN XE-3-HC 340S (Q-LAB ® Corporation, Westlake, OH, USA), which very closely simulates full-spectrum solar radiation. A dendrogram obtained from cluster analyses, based on lethal time 50 % and 90 % calculated by Probit analyses, separated the fungi into three clusters: cluster 3 contains species with highest tolerance to simulated full-spectrum solar radiation, included Metarhizium acridum, Cladosporium herbarum, and Trichothecium roseum with LT 50  > 200 min irradiation. Cluster 2 contains eight species with moderate UV tolerance: Aschersonia aleyrodis, Isaria fumosorosea, Mariannaea pruinosa, Metarhizium anisopliae, Metarhizium brunneum, Metarhizium robertsii, Simplicillium lanosoniveum, and Torrubiella homopterorum with LT 50 between 120 and 150 min irradiation. The four species in cluster 1 had the lowest UV tolerance: Lecanicillium aphanocladii, Beauveria bassiana, Tolypocladium cylindrosporum, and Tolypocladium inflatum with LT 50  solar radiation before. We conclude that the equipment provided an excellent tool for testing realistic tolerances of fungi to full-spectrum solar radiation of microbial agents for insect biological control in agriculture. Copyright © 2018 British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  3. Mars Array Technology Experiment Developed to Test Solar Arrays on Mars

    Science.gov (United States)

    Landis, Geoffrey A.

    2001-01-01

    and two different solar cell strings, to qualify advanced solar cell types for future Mars missions. The MATE instrument, designed for the Mars-2001 Surveyor Lander mission, contains a capable suite of sensors that will provide both scientific information as well as important engineering data on the operation of solar power systems on Mars. MATE will characterize the intensity and spectrum of the solar radiation on Mars and measure the performance of solar arrays in the Mars environment. MATE flight hardware was built and tested at the NASA Glenn Research Center and is ready for flight.

  4. Solar energy storage via liquid filled cans - Test data and analysis

    Science.gov (United States)

    Saha, H.

    1978-01-01

    This paper describes the design of a solar thermal storage test facility with water-filled metal cans as heat storage medium and also presents some preliminary tests results and analysis. This combination of solid and liquid mediums shows unique heat transfer and heat contents characteristics and will be well suited for use with solar air systems for space and hot water heating. The trends of the test results acquired thus far are representative of the test bed characteristics while operating in the various modes.

  5. High-Fidelity Solar Power Income Modeling for Solar-Electric UAVs: Development and Flight Test Based Verification

    OpenAIRE

    Oettershagen, Philipp

    2017-01-01

    Solar power models are a crucial element of solar-powered UAV design and performance analysis. During the conceptual design phase, their accuracy directly relates to the accuracy of the predicted performance metrics and thus the final design characteristics of the solar-powered UAV. Likewise, during the operations phase of a solar-powered UAV accurate solar power income models are required to predict and assess the solar power system performance. However, the existing literature on solar-powe...

  6. Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1996-01-01

    1.1 This test method covers the measurement of solar photometric transmittance of materials in sheet form. Solar photometric transmittance is measured using a photometer (illuminance meter) in an enclosure with the sun and sky as the source of radiation. The enclosure and method of test is specified in Test Method E 1175 (or Test Method E 1084). 1.2 The purpose of this test method is to specify a photometric sensor to be used with the procedure for measuring the solar photometric transmittance of sheet materials containing inhomogeneities in their optical properties. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Real-time and accelerated outdoor endurance testing of solar cells

    Science.gov (United States)

    Forestieri, A. F.; Anagnostou, E.

    1977-01-01

    Real-time and accelerated outdoor endurance testing was performed on a variety of samples of interest to the National Photovoltaic Conversion Program. The real-time tests were performed at seven different sites and the accelerated tests were performed at one of those sites in the southwestern United States. The purpose of the tests were to help evaluate the lifetime of photovoltaic systems. Three types of samples were tested; transmission samples of possible cover materials, sub-modules constructed using these materials attached to solar cells, and solar cell modules produced by the manufacturers for the ERDA program. Results indicate that suitable cover materials are glass, FEP-A and PFA. Dirt accumulation and cleanability are important factors in the selection of solar cell module covers and encapsulants.

  8. Evaluation of initial collector field performance at the Langley Solar Building Test Facility

    Science.gov (United States)

    Boyle, R. J.; Knoll, R. H.; Jensen, R. N.

    1977-01-01

    The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

  9. Electrical design for origami solar panels and a small spacecraft test mission

    Science.gov (United States)

    Drewelow, James; Straub, Jeremy

    2017-05-01

    Efficient power generation is crucial to the design of spacecraft. Mass, volume, and other limitations prevent the use of traditional spacecraft support structures from being suitable for the size of solar array required for some missions. Folding solar panel / panel array systems, however, present a number of design challenges. This paper considers the electrical design of an origami system. Specifically, it considers how to provide low impedance, durable channels for the generated power and the electrical aspects of the deployment system and procedure. The ability to dynamically reconfigure the electrical configuration of the solar cells is also discussed. Finally, a small satellite test mission to demonstrate the technology is proposed, before concluding.

  10. Towards standardized testing methodologies for optical properties of components in concentrating solar thermal power plants

    Science.gov (United States)

    Sallaberry, Fabienne; Fernández-García, Aránzazu; Lüpfert, Eckhard; Morales, Angel; Vicente, Gema San; Sutter, Florian

    2017-06-01

    Precise knowledge of the optical properties of the components used in the solar field of concentrating solar thermal power plants is primordial to ensure their optimum power production. Those properties are measured and evaluated by different techniques and equipment, in laboratory conditions and/or in the field. Standards for such measurements and international consensus for the appropriate techniques are in preparation. The reference materials used as a standard for the calibration of the equipment are under discussion. This paper summarizes current testing methodologies and guidelines for the characterization of optical properties of solar mirrors and absorbers.

  11. Comprehensive behavioural analysis of Long Evans and Sprague-Dawley rats reveals differential effects of housing conditions on tests relevant to neuropsychiatric disorders.

    Directory of Open Access Journals (Sweden)

    Karly M Turner

    Full Text Available Genetic (G and environmental (E manipulations are known to alter behavioural outcomes in rodents, however many animal models of neuropsychiatric disorders only use a restricted selection of strain and housing conditions. The aim of this study was to examine GxE interactions comparing two outbred rat strains, which were housed in either standard or enriched cages. The strains selected were the albino Sprague-Dawley rat, commonly used for animal models, and the other was the pigmented Long Evans rat, which is frequently used in cognitive studies. Rats were assessed using a comprehensive behavioural test battery and included well-established tests frequently employed to examine animal models of neuropsychiatric diseases, measuring aspects of anxiety, exploration, sensorimotor gating and cognition. Selective strain and housing effects were observed on a number of tests. These included increased locomotion and reduced pre-pulse inhibition in Long Evans rats compared to Sprague Dawley rats; and rats housed in enriched cages had reduced anxiety-like behaviour compared to standard housed rats. Long Evans rats required fewer sessions than Sprague Dawley rats to learn operant tasks, including a signal detection task and reversal learning. Furthermore, Long Evans rats housed in enriched cages acquired simple operant tasks faster than standard housed Long Evans rats. Cognitive phenotypes in animal models of neuropsychiatric disorders would benefit from using strain and housing conditions where there is greater potential for both enhancement and deficits in performance.

  12. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Fenaughty, Karen [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States); Lubliner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States)

    2018-01-15

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  13. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Fenaughty, Karen [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States); Lubiner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States)

    2018-01-29

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  14. Analysis of solar thermophotovoltaic test data from experiments performed at McDonnell Douglas

    Energy Technology Data Exchange (ETDEWEB)

    Stone, K.W.; Kusek, S.M.; Drubka, R.E. [McDonnell Douglas, 5301 Bolsa Avenue, Huntington Beach, California 92647 (United States); Fay, T.D. [21911 Bacalar, Mission Viejo, California 92692 (United States)

    1995-01-05

    Solar thermophotovoltaic power systems offer potentially high system efficiency for solar energy to electrical energy conversion and attractive system advantages. McDonnell Douglas Corporation (MDC) has been investigating this technology for both space and terrestrial applications for several years. A testbed prototype was designed, built, and tested on a 90 kW{sub t} dish concentrator at the MDA solar test facility. Twelve experiments were conducted with absorber temperatures in excess of 1300 {degree}C being achieved using only a fraction of the reflected power from the 90 kW{sub t} dish concentrator. This paper discusses the solar thermophotovoltaic testbed prototype unit, test data, and presents an analysis of the unit`s performance. A combination of analytical analysis and test data is used to obtain an understanding of the system and subsystem performance. The preliminary results of these tests and analysis indicate a solar thermophotovoltaic power system can achieve high system performance. Furthermore, system demonstrations are possible utilizing a combination of current off-the-shelf hardware components and components currently being tested in laboratories. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  15. HIV drug resistance testing among patients failing second line antiretroviral therapy. Comparison of in-house and commercial sequencing.

    Science.gov (United States)

    Chimukangara, Benjamin; Varyani, Bhavini; Shamu, Tinei; Mutsvangwa, Junior; Manasa, Justen; White, Elizabeth; Chimbetete, Cleophas; Luethy, Ruedi; Katzenstein, David

    2017-05-01

    HIV genotyping is often unavailable in low and middle-income countries due to infrastructure requirements and cost. We compared genotype resistance testing in patients with virologic failure, by amplification of HIV pol gene, followed by "in-house" sequencing and commercial sequencing. Remnant plasma samples from adults and children failing second-line ART were amplified and sequenced using in-house and commercial di-deoxysequencing, and analyzed in Harare, Zimbabwe and at Stanford, U.S.A, respectively. HIV drug resistance mutations were determined using the Stanford HIV drug resistance database. Twenty-six of 28 samples were amplified and 25 were successfully genotyped. Comparison of average percent nucleotide and amino acid identities between 23 pairs sequenced in both laboratories were 99.51 (±0.56) and 99.11 (±0.95), respectively. All pairs clustered together in phylogenetic analysis. Sequencing analysis identified 6/23 pairs with mutation discordances resulting in differences in phenotype, but these did not impact future regimens. The results demonstrate our ability to produce good quality drug resistance data in-house. Despite discordant mutations in some sequence pairs, the phenotypic predictions were not clinically significant. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Microclimate measuring and fluid‑dynamic simulation in an industrial broiler house: testing of an experimental ventilation system.

    Science.gov (United States)

    Bianchi, Biagio; Giametta, Ferruccio; La Fianza, Giovanna; Gentile, Andrea; Catalano, Pasquale

    2015-01-01

    The environment in the broiler house is a combination of physical and biological factors generating a complex dynamic system of interactions between birds, husbandry system, light, temperature, and the aerial environment. Ventilation plays a key role in this scenario. It is pivotal to remove carbon dioxide and water vapor from the air of the hen house. Adequate ventilation rates provide the most effective method of controlling temperature within the hen house. They allow for controlling the relative humidity and can play a key role in alleviating the negative effects of high stocking density and of wet litter. In the present study the results of experimental tests performed in a breeding broiler farm are shown. In particular the efficiency of a semi transversal ventilation system was studied against the use of a pure transversal one. In order to verify the efficiency of the systems, fluid dynamic simulations were carried out using the software Comsol multiphysics. The results of this study show that a correct architectural and structural design of the building must be supported by a design of the ventilation system able to maintain the environmental parameters within the limits of the thermo‑neutral and welfare conditions and to achieve the highest levels of productivity.

  17. PROGRAM ASTEC (ADVANCED SOLAR TURBO ELECTRIC CONCEPT). PART 1. CANDIDATE MATERIALS LABORATORY TESTS

    Science.gov (United States)

    A space power system of the type envisioned by the ASTEC program requires the development of a lightweight solar collector of high reflectance...capable of withstanding the space environment for an extended period. A survey of the environment of interest for ASTEC purposes revealed 4 potential...developed by the solar-collector industry for use in the ASTEC program, and to test the effects of space environment on these materials. Of 6 material

  18. Extension of the ACE solar panels is tested in SAEF-II

    Science.gov (United States)

    1997-01-01

    Extension of the solar panels is tested on the Advanced Composition Explorer (ACE) spacecraft in KSC's Spacecraft Assembly and Encapsulation Facility-II (SAEF-II). Scheduled for launch on a Delta II rocket from Cape Canaveral Air Station on Aug. 25, ACE will study low-energy particles of solar origin and high-energy galactic particles. The collecting power of instruments aboard ACE is 10 to 1,000 times greater than anything previously flown to collect similar data by NASA.

  19. A pilot test of a motivational interviewing social network intervention to reduce substance use among housing first residents.

    Science.gov (United States)

    Kennedy, David P; Osilla, Karen Chan; Hunter, Sarah B; Golinelli, Daniela; Maksabedian Hernandez, Ervant; Tucker, Joan S

    2018-03-01

    This article presents findings of a pilot test of a Motivational Interviewing social network intervention (MI-SNI) to enhance motivation to reduce high risk alcohol and other drug (AOD) use among formerly homeless individuals transitioning to housing. Delivered in-person by a facilitator trained in MI, this four-session computer-assisted intervention provides personalized social network visualization feedback to help participants understand the people in their network who trigger their alcohol and other drug (AOD) use and those who support abstinence. If ready, participants are encouraged to make changes to their social network to help reduce their own high-risk behavior. Participants were 41 individuals (33 male, 7 female, 1 other; 23 African-American, 5 non-Latino White, 6 Latino, 7 other, mean age 48) who were transitioning from homelessness to permanent supportive housing. They were randomly assigned to either the MI-SNI condition or usual care. Readiness to change AOD use, AOD abstinence self-efficacy, and AOD use were assessed at baseline and shortly after the final intervention session for the MI-SNI arm and around 3-months after baseline for the control arm. Acceptability of the intervention was also evaluated. MI-SNI participants reported increased readiness to change AOD use compared to control participants. We also conducted a subsample analysis for participants at one housing program and found a significant intervention effect on readiness to change AOD use, AOD abstinence self-efficacy, and alcohol use compared to control participants. Participants rated the intervention as highly acceptable. We conclude that a brief computer-assisted Motivational Interviewing social network intervention has potential to efficaciously impact readiness to change AOD use, AOD abstinence self-efficacy, and AOD use among formerly homeless individuals transitioning to permanent supportive housing, and warrants future study in larger clinical trials. Copyright © 2017

  20. Project, fabrication, assembly and tests of different prototypes for CPS compound parabolic solar collectors; Projeto, fabricacao, montagem e testes de diferentes prototipos de coletores solares parabolicos compostos CPCs

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefemg.br

    2000-07-01

    This work presents the results of the experiment involving the design, fabrication, assembly and tests of composite parabolic solar collectors prototypes with acceptance half-angles of 3 deg C, 6.5 deg C, 11 deg C, 14 deg C and 19.5 deg C of the tube type absorber and 14 deg C rectangular absorber. Field test were performed on all the prototypes for determination of thermal efficiency, time constants and optical efficiencies represented by the modified incidence angles. Tests were performed for the determination of the heat transfer global coefficients on each prototype. (author)

  1. Simulation of the charging process of the LISA test masses due to solar flares

    International Nuclear Information System (INIS)

    Vocca, H; Grimani, C; Amico, P; Bosi, L; Marchesoni, F; Punturo, M; Travasso, F; Barone, M; Stanga, R; Vetrano, F; Vicere, A

    2004-01-01

    Cosmic-ray and solar high energy particles penetrate the LISA experiment test masses. Consequently, an electric charge accumulates in the bodies of the masses, generating spurious Coulomb forces between the masses and the surrounding electrodes. This process increases the noise level of the experiment. We have estimated the amount of charge deposited per second on the LISA test masses by solar flares and primary cosmic-ray protons at solar minimum. The simulation has been carried out with the Fluka Monte Carlo program. A simplified geometry for the experiment has been considered. We have found a net charging rate of 37 ± 1 e + /s for primary protons at solar minimum between 0.1 and 1000 GeV/n. The amount of charge released by a medium-strong solar flare, like that of 16 February 1984, is 10 732 ± 30 e + /s in the energy range 0.1-10 GeV/n. This value increases or decreases by approximately one order of magnitude for strong (weak) solar flares

  2. Solar wind stream evolution at large heliocentric distances - Experimental demonstration and the test of a model

    Science.gov (United States)

    Gosling, J. T.; Hundhausen, A. J.; Bame, S. J.

    1976-01-01

    A stream propagation model which neglects all dissipation effects except those occurring at shock interfaces, was used to compare Pioneer-10 solar wind speed observations, during the time when Pioneer 10, the earth, and the sun were coaligned, with near-earth Imp-7 observations of the solar wind structure, and with the theoretical predictions of the solar wind structure at Pioneer 10 derived from the Imp-7 measurements, using the model. The comparison provides a graphic illustration of the phenomenon of stream steepening in the solar wind with the attendant formation of forward-reverse shock pairs and the gradual decay of stream amplitudes with increasing heliocentric distance. The comparison also provides a qualitative test of the stream propagation model.

  3. DEVELOPMENT AND PRELIMINARY TESTING OF A PARABOLIC TROUGH SOLAR WATER HEATER

    Directory of Open Access Journals (Sweden)

    O. A. Lasode

    2011-06-01

    Full Text Available Solar energy is a high-temperature, high-energy radiant energy source, with tremendous advantages over other alternative energy sources. It is a reliable, robust renewable resource which is largely undeveloped. The design and fabrication of parabolic trough solar water heater for water heating was executed. The procedure employed includes the design, construction and testing stages. The equipment which is made up of the reflector surface (curved mirror, reflector support, absorber pipe and a stand was fabricated using locally sourced materials. The results obtained. compared favourably with other research works in the literature. It depicts that employing a suitable design, selection of time of heating and proper focusing of the reflected rays to the focal spot region, solar radiation can efficiently be utilized for water heating in a tropical environment. This work presents a parabolic trough solar water heater as a suitable renewable energy technology for reducing water-heating costs.

  4. Models of f(R) cosmic acceleration that evade solar system tests

    International Nuclear Information System (INIS)

    Hu, Wayne; Sawicki, Ignacy

    2007-01-01

    We study a class of metric-variation f(R) models that accelerates the expansion without a cosmological constant and satisfies both cosmological and solar-system tests in the small-field limit of the parameter space. Solar-system tests alone place only weak bounds on these models, since the additional scalar degree of freedom is locked to the high-curvature general-relativistic prediction across more than 25 orders of magnitude in density, out through the solar corona. This agreement requires that the galactic halo be of sufficient extent to maintain the galaxy at high curvature in the presence of the low-curvature cosmological background. If the galactic halo and local environment in f(R) models do not have substantially deeper potentials than expected in ΛCDM, then cosmological field amplitudes |f R | > or approx.10 -6 will cause the galactic interior to evolve to low curvature during the acceleration epoch. Viability of large-deviation models therefore rests on the structure and evolution of the galactic halo, requiring cosmological simulations of f(R) models, and not directly on solar-system tests. Even small deviations that conservatively satisfy both galactic and solar-system constraints can still be tested by future, percent-level measurements of the linear power spectrum, while they remain undetectable to cosmological-distance measures. Although we illustrate these effects in a specific class of models, the requirements on f(R) are phrased in a nearly model-independent manner

  5. Solar Sail Models and Test Measurements Correspondence for Validation Requirements Definition

    Science.gov (United States)

    Ewing, Anthony; Adams, Charles

    2004-01-01

    Solar sails are being developed as a mission-enabling technology in support of future NASA science missions. Current efforts have advanced solar sail technology sufficient to justify a flight validation program. A primary objective of this activity is to test and validate solar sail models that are currently under development so that they may be used with confidence in future science mission development (e.g., scalable to larger sails). Both system and model validation requirements must be defined early in the program to guide design cycles and to ensure that relevant and sufficient test data will be obtained to conduct model validation to the level required. A process of model identification, model input/output documentation, model sensitivity analyses, and test measurement correspondence is required so that decisions can be made to satisfy validation requirements within program constraints.

  6. Compendium of information on identification and testing of materials for plastic solar thermal collectors

    Energy Technology Data Exchange (ETDEWEB)

    McGinniss, V.D.; Sliemers, F.A.; Landstrom, D.K.; Talbert, S.G.

    1980-07-31

    This report is intended to organize and summarize prior and current literature concerning the weathering, aging, durability, degradation, and testing methodologies as applied to materials for plastic solar thermal collectors. Topics covered include (1) rate of aging of polymeric materials; (2) environmental factors affecting performance; (3) evaluation and prediction of service life; (4) measurement of physical and chemical properties; (5) discussion of evaluation techniques and specific instrumentation; (6) degradation reactions and mechanisms; (7) weathering of specific polymeric materials; and (8) exposure testing methodology. Major emphasis has been placed on defining the current state of the art in plastics degradation and on identifying information that can be utilized in applying appropriate and effective aging tests for use in projecting service life of plastic solar thermal collectors. This information will also be of value where polymeric components are utilized in the construction of conventional solar collectors or any application where plastic degradation and weathering are prime factors in material selection.

  7. Research and demonstration facilities for energy conservation and solar heating in the home

    Science.gov (United States)

    Newman, J. O.; Godbey, L. C.; Davis, M. A.; Ezell, D. O.; Allen, W. H.

    1981-10-01

    The design, testing and evaluation of two prototype solar holes are discussed. The first prototype is a greenhouse-residence designed with 6-in. wall cavities (to increase insulation thickness), a 381 sq. ft. solar collector used primarily for space heating, and a greenhouse that was utilized as a solar collector for growing vegetables. The house does feature a domestic hot water preheating system and an electrical resistance back-up heating system. The second prototype is an earth-insulated house designed primarily to study the physical features of the house in relation to the soil around it and the thermal interaction between the soil and the house environment. This house features a high temperature air collector that is used for domestic water heating. A special effort was made to have adequate daylight in the solar-earth house. A special study was conducted on the geometric configuration of the rock storage and the methods of admitting air to the rock storage.

  8. Housing Characteristics, 1990

    International Nuclear Information System (INIS)

    1992-01-01

    This report on energy consumption in the residential sector covers the following topics: housing trends 1980--1990, new housing trends, availability and usage of natural gas by households, changes in appliance usage (refrigerators, entertainment appliances, cooking appliances, convenience appliances), age of major household appliances and equipment, household energy conservation activities, demand-side management programs, and a portrait of households using solar or wood as a source of energy

  9. A new Laplace transformation method for dynamic testing of solar collectors

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Perers, Bengt; Fan, Jianhua

    2015-01-01

    A new dynamic method for solar collector testing is developed. It is characterized by using the Laplace transformation technique to solve the differential governing equation. The new method was inspired by the so called New Dynamic Method (NDM) (Amer E. et al (1999) [1]) but totally different....... By integration of the Laplace transformation technique with the Quasi Dynamic Test (QDT) model (Fischer S. et al (2004) [2]), the Laplace – QDT (L-QDT) model is derived. Two experimental methods are then introduced. One is the shielding method which needs to shield and un-shield solar collector continuously...

  10. Exposure testing and evaluation of solar utilization materials. Semiannual report, May 1, 1975--October 31, 1975

    Energy Technology Data Exchange (ETDEWEB)

    Gilligan, J.E.; Brzuskiewicz, J.

    1975-01-01

    The initial efforts of a program of research and experimental testing is described in which the optical performance of materials for use in solar energy utilization devices will be determined before and after exposure to outdoor weathering tests. Materials which are currently in use and others which are being considered or developed for these applications will be characterized and exposed to natural solar radiation. Outdoor testing will be accomplished in Phoenix (Ariz.), Miami (Fla.), and Chicago (Ill.). The results of these tests, primarily the effects of outdoor exposure on optical and physical properties, will be compiled in a handbook, along with cost, availability and other pertinent information. These data are vital to the intelligent selection of solar utilization materials, since a knowledge of the cost performance and lifetime characteristics of candidate materials will greatly assist the design of efficient and reliable solar energy utilization devices. Primary accomplishments include the definition of sample requirements, specification of test samples and test configurations, formulation of acceptance/rejection criteria and contacts with numerous potential materials suppliers.

  11. Compatibility tests between Solar Salt and thermal storage ceramics from inorganic industrial wastes

    International Nuclear Information System (INIS)

    Motte, Fabrice; Falcoz, Quentin; Veron, Emmanuel; Py, Xavier

    2015-01-01

    Highlights: • ESEM and XRD characterizations have been performed. • Compatibility of these ceramics with the conventional binary Solar Salt is tested at 500 °C. • Tested ceramics have relevant properties to store thermal energy up to 1000 °C. • Feasibility of using ceramics as filler materials in thermocline is demonstrated. - Abstract: This paper demonstrates the feasibility of using several post-industrial ceramics as filler materials in a direct thermocline storage configuration. The tested ceramics, coming from several industrial processes (asbestos containing waste treatment, coal fired power plants or metallurgic furnaces) demonstrate relevant properties to store thermal energy by sensible heat up to 1000 °C. Thus, they represent at low-cost a promising, efficient and sustainable approach for thermal energy storage. In the present study, the thermo-chemical compatibility of these ceramics with the conventional binary Solar Salt is tested at medium temperature (500 °C) under steady state. In order to determine the feasibility of using such ceramics as filler material, Environmental Scanning Electron Microscopy (ESEM) and X-Ray Diffraction (XRD) characterizations have been performed to check for their chemical and structural evolution during corrosion tests. The final objective is to develop a molten salt thermocline direct storage system using low-cost shaped ceramic as structured filler material. Most of the tested ceramics present an excellent corrosion resistance in molten Solar Salt and should significantly decrease the current cost of concentrated solar thermal energy storage system

  12. Solar Systems

    Science.gov (United States)

    1979-01-01

    The solar collectors shown are elements of domestic solar hot water systems produced by Solar One Ltd., Virginia Beach, Virginia. Design of these systems benefited from technical expertise provided Solar One by NASA's Langley Research Center. The company obtained a NASA technical support package describing the d e sign and operation of solar heating equipment in NASA's Tech House, a demonstration project in which aerospace and commercial building technology are combined in an energy- efficient home. Solar One received further assistance through personal contact with Langley solar experts. The company reports that the technical information provided by NASA influenced Solar One's panel design, its selection of a long-life panel coating which increases solar collection efficiency, and the method adopted for protecting solar collectors from freezing conditions.

  13. Performance Test of Parabolic Trough Solar Cooker for Indoor ...

    African Journals Online (AJOL)

    Bheema

    mm diameter copper pipe is the optimum size for the absorber. Maximum temperatures of ... This paper deals with improving and testing performance of a concentrating cooker for indoor cooking with ... bean oil Soya bean oil. Coating material.

  14. Solar collector array

    Science.gov (United States)

    Hall, John Champlin; Martins, Guy Lawrence

    2015-09-06

    A method and apparatus for efficient manufacture, assembly and production of solar energy. In one aspect, the apparatus may include a number of modular solar receiver assemblies that may be separately manufactured, assembled and individually inserted into a solar collector array housing shaped to receive a plurality of solar receivers. The housing may include optical elements for focusing light onto the individual receivers, and a circuit for electrically connecting the solar receivers.

  15. The ground testing of a 2 kWe solar dynamic space power system

    International Nuclear Information System (INIS)

    Calogeras, J.E.

    1992-01-01

    Over the past 25 years Space Solar Dynamic component development has advanced to the point where it is considered a leading candidate power source technology for the evolutionary phases of the Space Station Freedom (SSF) program. Selection of SD power was based on studies and analyses which indicated significant savings in life cycle costs, launch mass and EVA requirements were possible when the system is compared to more conventional photovoltaic/battery power systems. Issues associated with micro-gravity operation such as the behavior of the thermal energy storage materials are being addressed in other programs. This paper reports that a ground test of a 2 kWe solar dynamic system is being planned by the NASA Office of Aeronautics and Space Technology to address the integration issues. The test will be scalable up to 25 kWe, will be flight configured and will incorporate relevant features of the SSF Solar Dynamic Power Module design

  16. Low frequency noise as a control test for spacial solar panels

    Science.gov (United States)

    Orsal, B.; Alabedra, R.; Ruas, R.

    1986-07-01

    The present study of low frequency noise in a forward-biased dark solar cell, in order to develop an NDE test method for solar panels, notes that a single cell with a given defect is thus detectable under dark conditions. The test subject was a space solar panel consisting of five cells in parallel and five in series; these cells are of the n(+)-p monocrystalline Si junction type. It is demonstrated that the noise associated with the defective cell is 10-15 times higher than that of a good cell. Replacement of a good cell by a defective one leads to a 30-percent increase in the noise level of the panel as a whole.

  17. GUC100 multisensor fingerprint database for in-house (semipublic) performance test

    OpenAIRE

    Gafurov D.; Bours P.; Yang B.; Busch C.

    2010-01-01

    For evaluation of biometric performance of biometric components and system, the availability of independent databases and desirably independent evaluators is important. Both databases of significant size and independent testing institutions provide the precondition for fair and unbiased benchmarking. In order to show generalization capabilities of the system under test, it is essential that algorithm developers do not have access to the testing database, and thus the risk of tuned algorithms...

  18. Near Earth Asteroid Scout Solar Sail Engineering Development Unit Test Suite

    Science.gov (United States)

    Lockett, Tiffany Russell; Few, Alexander; Wilson, Richard

    2017-01-01

    The Near Earth Asteroid (NEA) Scout project is a 6U reconnaissance mission to investigate a near Earth asteroid utilizing an 86m(sub 2) solar sail as the primary propulsion system. This will be the largest solar sail NASA has launched to date. NEA Scout is currently manifested on the maiden voyage of the Space Launch System in 2018. In development of the solar sail subsystem, design challenges were identified and investigated for packaging within a 6U form factor and deployment in cis-lunar space. Analysis was able to capture understanding of thermal, stress, and dynamics of the stowed system as well as mature an integrated sail membrane model for deployed flight dynamics. Full scale system testing on the ground is the optimal way to demonstrate system robustness, repeatability, and overall performance on a compressed flight schedule. To physically test the system, the team developed a flight sized engineering development unit with design features as close to flight as possible. The test suite included ascent vent, random vibration, functional deployments, thermal vacuum, and full sail deployments. All of these tests contributed towards development of the final flight unit. This paper will address several of the design challenges and lessons learned from the NEA Scout solar sail subsystem engineering development unit. Testing on the component level all the way to the integrated subsystem level. From optical properties of the sail material to fold and spooling the single sail, the team has developed a robust deployment system for the solar sail. The team completed several deployments of the sail system in preparation for flight at half scale (4m) and full scale (6.8m): boom only, half scale sail deployment, and full scale sail deployment. This paper will also address expected and received test results from ascent vent, random vibration, and deployment tests.

  19. Performance testing of a Fresnel/Stirling micro solar energy conversion system

    International Nuclear Information System (INIS)

    Aksoy, Fatih; Karabulut, Halit

    2013-01-01

    Highlights: • Solar energy has a big importance among the renewable energy sources. • A micro solar energy system consisted of a Stirling engine and Fresnel lens was tested. • Solar radiation was directly focused into a cavity. • Cavities made of copper, aluminium and stainless steel were used. • The maximum performance was obtained with aluminium cavity. - Abstract: In this study, a beta-type Stirling engine was tested with concentrated solar radiation. The displacer cylinder of the engine was modified by integrating a concentrated solar radiation receiver. Basically, the receiver is a cavity drilled in a separate part mounted on top of the displacer cylinder by screws. Tests were conducted with three cavities made of aluminium, copper and stainless steel. The solar radiation was concentrated by a Fresnel lens with 1.4 m 2 capture area. Among the cavities, the highest performance was provided by aluminium cavity and followed by the stainless steel and copper cavities respectively. The maximum shaft power was observed as 64.4 W at systematic tests conducted with the aluminium cavity. The maximum shaft power corresponded to 218 rpm engine speed and 2.82 Nm torque. For this shaft power, the overall conversion efficiency of the system was estimated to be 5.64%. The maximum torque measured with aluminium cavity was 2.93 Nm corresponding to 177 rpm below which the engine stopped. The Fresnel-lens/Stirling-engine micro power plant established in this investigation was more efficient than the micro power plants presented in the literature

  20. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine; Ton, Wei-Zhe; Wu, Chen-Chun; Ko, Hua-Wei; Chang, Hsien-Shun; Hsu, Hang-Yuen; Liu, Jen-Hao; Wu, Jia-Hung; Yen, Rue-Her

    2014-01-01

    are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well

  1. Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard

    Science.gov (United States)

    Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly

    2017-08-01

    The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period

  2. Insulated Concrete Form Walls Integrated With Mechanical Systems in a Cold Climate Test House

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, D.; Wiehagen, J.

    2014-09-01

    Transitioning from standard light frame to a thermal mass wall system in a high performance home will require a higher level of design integration with the mechanical systems. The much higher mass in the ICF wall influences heat transfer through the wall and affects how the heating and cooling system responds to changing outdoor conditions. This is even more important for efficient, low-load homes with efficient heat pump systems in colder climates where the heating and cooling peak loads are significantly different from standard construction. This report analyzes a range of design features and component performance estimates in an effort to select practical, cost-effective solutions for high performance homes in a cold climate. Of primary interest is the influence of the ICF walls on developing an effective air sealing strategy and selecting an appropriate heating and cooling equipment type and capacity. The domestic water heating system is analyzed for costs and savings to investigate options for higher efficiency electric water heating. A method to ensure mechanical ventilation air flows is examined. The final solution package includes high-R mass walls, very low infiltration rates, multi-stage heat pump heating, solar thermal domestic hot water system, and energy recovery ventilation. This solution package can be used for homes to exceed 2012 International Energy Conservation Code requirements throughout all climate zones and achieves the DOE Challenge Home certification.

  3. Closed Cycle Engine Program Used in Solar Dynamic Power Testing Effort

    Science.gov (United States)

    Ensworth, Clint B., III; McKissock, David B.

    1998-01-01

    NASA Lewis Research Center is testing the world's first integrated solar dynamic power system in a simulated space environment. This system converts solar thermal energy into electrical energy by using a closed-cycle gas turbine and alternator. A NASA-developed analysis code called the Closed Cycle Engine Program (CCEP) has been used for both pretest predictions and post-test analysis of system performance. The solar dynamic power system has a reflective concentrator that focuses solar thermal energy into a cavity receiver. The receiver is a heat exchanger that transfers the thermal power to a working fluid, an inert gas mixture of helium and xenon. The receiver also uses a phase-change material to store the thermal energy so that the system can continue producing power when there is no solar input power, such as when an Earth-orbiting satellite is in eclipse. The system uses a recuperated closed Brayton cycle to convert thermal power to mechanical power. Heated gas from the receiver expands through a turbine that turns an alternator and a compressor. The system also includes a gas cooler and a radiator, which reject waste cycle heat, and a recuperator, a gas-to-gas heat exchanger that improves cycle efficiency by recovering thermal energy.

  4. Optimal control and performance test of solar-assisted cooling system

    KAUST Repository

    Huang, B.J.

    2010-10-01

    The solar-assisted cooling system (SACH) was developed in the present study. The ejector cooling system (ECS) is driven by solar heat and connected in parallel with an inverter-type air conditioner (A/C). The cooling load can be supplied by the ECS when solar energy is available and the input power of the A/C can be reduced. In variable weather, the ECS will probably operate at off-design condition of ejector and the cooling capability of the ECS can be lost completely. In order to make the ejector operate at critical or non-critical double-choking condition to obtain a better performance, an electronic expansion valve was installed in the suction line of the ejector to regulate the opening of the expansion valve to control the evaporator temperature. This will make the SACH always produce cooling effect even at lower solar radiation periods while the ejector performs at off-design conditions. The energy saving of A/C is experimentally shown 50-70% due to the cooling performance of ECS. The long-term performance test results show that the daily energy saving is around 30-70% as compared to the energy consumption of A/C alone (without solar-driven ECS). The total energy saving of A/C is 52% over the entire test period. © 2010 Elsevier Ltd. All rights reserved.

  5. Design, development, manufacture, testing, and delivery of devices for connection of solar cell panel circuitry to flat conductor cable solar cell array harness

    Science.gov (United States)

    Dillard, P. A.; Waddington, D.

    1971-01-01

    The technology status and problem areas which exist for the application of flat conductor cabling to solar cell arrays are summarized. Details covering the design, connector manufacture, and prototype test results are also summarized.

  6. Outdoor test method to determine the thermal behavior of solar domestic water heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Valladares, O.; Pilatowsky, I. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Privada Xochicalco, s/n, Colonia Centro, 62580 Temixco, Morelos (Mexico); Ruiz, V. [Escuela Tecnica Superior de Ingenieros, Universidad de Sevilla, Camino de los Descubrimientos, s/n, Isla de la Cartuja, 41092 Sevilla, Espana (Spain)

    2008-07-15

    The dynamics of the market, the generation of new promotion programs, fiscal incentives and many other factors are to be considered for the massive application of solar domestic water heating systems (SDWHS) mainly of the compact thermosiphon type, makes it necessary to choose simple and inexpensive procedure tests that permit to know their characteristic thermal behaviors without an official standard being necessary. Moreover, it allows the comparison among systems and offers enough and reliable information to consumers and manufacturers. In most developing countries, an official national standard for SDWHS is not available, therefore it is necessary to adopt an international test procedure in which the cost and time of implementation is very important. In this work, a simple and inexpensive test method to determine the thermal behavior of SDWHS is proposed. Even though these procedure tests do not have an official standard structure they permit, by comparing different solar systems under identical solar, ambient, and initial conditions, the experimental determination of: (a) the maximum available volume of water for solar heating; (b) water temperature increment and available thermal energy at the end of the day; (c) temperature profiles (stratification) and the average temperature in the storage tank after it is homogenized; (d) the average global thermal efficiency; (e) water temperature decrement and energy lost overnight; and (f) the relationship between hot water volume and solar collector area as function of the average heating temperature. An additional proposed test permits to know the heat losses caused by the reverse flow in the collector loop. These tests will be carried out independently of the configuration between the solar collector and the storage tank, the way the fluid circulates and the type of thermal exchange. The results of this procedure test can be very useful, firstly, for the local solar manufacturers' equipment in order to design

  7. Outdoor test method to determine the thermal behavior of solar domestic water heating systems

    International Nuclear Information System (INIS)

    Garcia-Valladares, O.; Pilatowsky, I.; Ruiz, V.

    2008-01-01

    The dynamics of the market, the generation of new promotion programs, fiscal incentives and many other factors are to be considered for the massive application of solar domestic water heating systems (SDWHS) mainly of the compact thermosiphon type, makes it necessary to choose simple and inexpensive procedure tests that permit to know their characteristic thermal behaviors without an official standard being necessary. Moreover, it allows the comparison among systems and offers enough and reliable information to consumers and manufacturers. In most developing countries, an official national standard for SDWHS is not available, therefore it is necessary to adopt an international test procedure in which the cost and time of implementation is very important. In this work, a simple and inexpensive test method to determine the thermal behavior of SDWHS is proposed. Even though these procedure tests do not have an official standard structure they permit, by comparing different solar systems under identical solar, ambient, and initial conditions, the experimental determination of: (a) the maximum available volume of water for solar heating; (b) water temperature increment and available thermal energy at the end of the day; (c) temperature profiles (stratification) and the average temperature in the storage tank after it is homogenized; (d) the average global thermal efficiency; (e) water temperature decrement and energy lost overnight; and (f) the relationship between hot water volume and solar collector area as function of the average heating temperature. An additional proposed test permits to know the heat losses caused by the reverse flow in the collector loop. These tests will be carried out independently of the configuration between the solar collector and the storage tank, the way the fluid circulates and the type of thermal exchange. The results of this procedure test can be very useful, firstly, for the local solar manufacturers' equipment in order to design and

  8. NPS Solar Cell Array Tester Cubesat Flight Testing and Integration

    Science.gov (United States)

    2014-09-01

    with current (I). P V I      (2.1) This is significant because the battery discharge test will not lineup perfectly with Figure 12...accordance with the charging procedures [13]. 3. NPS-SCAT Power Budget A power budget analysis was performed to determine if the NPS-SCAT is self...using procedures developed by Marissa Brummitt, and with the assistance of Adam Hill, NPS-SCAT Program Manager. 1. ELaNa IV Random Vibration Levels

  9. Verification test report on a solar heating and hot water system

    Science.gov (United States)

    1978-01-01

    Information is provided on the development, qualification and acceptance verification of commercial solar heating and hot water systems and components. The verification includes the performances, the efficiences and the various methods used, such as similarity, analysis, inspection, test, etc., that are applicable to satisfying the verification requirements.

  10. Design, construction and testing of a low-cost flat plate solar energy ...

    African Journals Online (AJOL)

    A low-cost flat plate solar energy collector has been designed and constructed with locally available materials such as mild steel and black paint of absorptance 0.94. On testing, an average daily efficiency of 55.6% was obtained. The methods are simple and illustrate the fact that construction of efficient collectors are ...

  11. Experimental test of a novel multi-surface trough solar concentrator for air heating

    International Nuclear Information System (INIS)

    Zheng Hongfei; Tao Tao; Ma Ming; Kang Huifang; Su Yuehong

    2012-01-01

    Highlights: ► We made a prototype novel multi-surface trough solar concentrator for air heating. ► Circular and rectangular types of receiver were chosen for air heating in the test. ► The changes of instantaneous system efficiency with different air flow were obtained. ► The system has the advantage of high collection temperature, which can be over 140 °C. ► The average efficiency can exceed 45% at the outlet temperature of above 60 °C. - Abstract: This study presents the experimental test of a novel multi-surface trough solar concentrator for air heating. Three receivers of different air flow channels are individually combined with the solar concentrator. The air outlet temperature and solar irradiance were recorded for different air flow rates under the real weather condition and used to determine the collection efficiency and time constant of the air heater system. The characteristics of the solar air heater with different airflow channels are compared, and the variation of the daily efficiency with the normalized temperature change is also presented. The testing results indicates that the highest temperature of the air heater with a circular glass receiver can be over 140 °C. When the collection temperature is around 60 °C, the collection efficiency can be over 45%. For the rectangular receivers, the system also has a considerable daily efficiency at a larger air flow rate. The air heater based on the novel trough solar concentrator would be suitable for space heating and drying applications.

  12. General Electric Company proposed test and evaluation plan, commercial buildings. National Solar Demonstration Program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1976-04-01

    The general requirements and methods for instrumenting, testing, and evaluating solar HVAC systems forming a part of ERDA's ''Commercial Demonstration Program'' commensurate with ERDA 23A and the Proposed Management Plan 75SDS4270 are defined. Design requirements are specified for the performance of components and subsystems comprising the instrumentation and data gathering system, as well as the support functions required to perform the diagnostic measurements, collection and processing of data, and documentation of reports on solar HVAC system performance, including economic and societal evaluations.

  13. Towards corrosion testing of unglazed solar absorber surfaces in simulated acid rain

    International Nuclear Information System (INIS)

    Salo, T.; Pehkonen, A.; Konttinen, P.; Lund, P.

    2005-01-01

    Electrochemical impedance spectroscopy and potentiodynamic polarization tests were utilized for determining corrosion probabilities of unglazed C/Al 2 O 3 /Al solar absorber surfaces in simulated acid rain. Previously, the main degradation mechanism found was exponentially temperature-related hydration of aluminium oxide. In acid rain tests the main corrosion determinant was the pH value of the rain. Results indicate that these methods measure corrosion characteristics of Al substrate instead of the C/Al 2 O 3 /Al surface, probably mainly due to the rough and non-uniform microstructure of the latter. Further analyses of the test methods are required in order to estimate their applicability on Al-based uniform sputtered absorber surfaces. (author) (C/Al 2 O 3 /Al solar absorber; Acid rain; Corrosion; Electrochemical tests)

  14. Real test-bed studies at the ETH House of Natural Resources – wood surface protection for outdoor applications

    Directory of Open Access Journals (Sweden)

    H. Guo

    2018-02-01

    Full Text Available The increasing demand for sustainable construction materials used in urban areas calls for novel wood protective coatings, which retain the natural appearance of wood while minimizing maintenance intervals. This work reports on three different wood surface modification processes and evaluates their protective effect against weathering after installation at a testing façade of the ETH House of Natural Resources (HoNR, a recently opened living lab located in Zürich, Switzerland. We monitored the discoloration upon outdoor exposure of subsequently improved generations of thin metal oxide coatings developed in our lab. We target almost transparent and durable coatings with water repellent properties to diminish discoloration due to UV light and biological attack. This should lead to wooden facades with increased reliability and thereby boost an enhanced utilization of the renewable and CO2 storing resource wood.

  15. Alpha test results for a Housing First eLearning strategy: the value of multiple qualitative methods for intervention design.

    Science.gov (United States)

    Ahonen, Emily Q; Watson, Dennis P; Adams, Erin L; McGuire, Alan

    2017-01-01

    Detailed descriptions of implementation strategies are lacking, and there is a corresponding dearth of information regarding methods employed in implementation strategy development. This paper describes methods and findings related to the alpha testing of eLearning modules developed as part of the Housing First Technical Assistance and Training (HFTAT) program's development. Alpha testing is an approach for improving the quality of a product prior to beta (i.e., real world) testing with potential applications for intervention development. Ten participants in two cities tested the modules. We collected data through (1) a structured log where participants were asked to record their experiences as they worked through the modules; (2) a brief online questionnaire delivered at the end of each module; and (3) focus groups. The alpha test provided useful data related to the acceptability and feasibility of eLearning as an implementation strategy, as well as identifying a number of technical issues and bugs. Each of the qualitative methods used provided unique and valuable information. In particular, logs were the most useful for identifying technical issues, and focus groups provided high quality data regarding how the intervention could best be used as an implementation strategy. Alpha testing was a valuable step in intervention development, providing us an understanding of issues that would have been more difficult to address at a later stage of the study. As a result, we were able to improve the modules prior to pilot testing of the entire HFTAT. Researchers wishing to alpha test interventions prior to piloting should balance the unique benefits of different data collection approaches with the need to minimize burdens for themselves and participants.

  16. Astrometric tests of General Relativity in the Solar system

    International Nuclear Information System (INIS)

    Gai, M; Vecchiato, A; Riva, A; Lattanzi, M G; Sozzetti, A; Crosta, M T; Busonero, D

    2014-01-01

    Micro-arcsec astronomy is able to verify the predictions of theoretical models of gravitation at a level adequate to constraint relevant parameters and select among different formulations. In particular, this concerns the weak field limit applicable to the Sun neighborhood, where competing models can be expressed in a common framework as the Parametrised Post-Newtonian and Parametrised Post-Post-Newtonian formulations. The mission Gaia is going to provide an unprecedented determination of the γ PPN parameter at the 10 −6 level. Other recently proposed concepts, as GAME, may improve the precision on γ by one or two orders of magnitude and provide constraints on other crucial phenomenological aspects. We review the key concepts of astrometric tests of General Relativity and discuss a possible development scenario

  17. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  18. Standardized performance tests of collectors of solar thermal energy: A selectively coated, steel collector with one transparent cover

    Science.gov (United States)

    1976-01-01

    Basic test results are presented of a flat-plate solar collector whose performance was determined in solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency was correlated in terms of inlet temperature and flux level.

  19. Standardized performance tests of collectors of solar thermal energy: An evacuated flatplate copper collector with a serpentine flow distribution

    Science.gov (United States)

    Johnson, S. M.

    1976-01-01

    Basic test results are given for a flat plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  20. TRL Assessment of Solar Sail Technology Development Following the 20-Meter System Ground Demonstrator Hardware Testing

    Science.gov (United States)

    Young, Roy M.; Adams, Charles L.

    2010-01-01

    The NASA In-Space Propulsion Technology (ISPT) Projects Office sponsored two separate, independent solar sail system design and development demonstration activities during 2002-2005. ATK Space Systems of Goleta, CA was the prime contractor for one development team and L' Garde, Inc. of Tustin, CA was the prime contractor for the other development team. The goal of these activities was to advance the technology readiness level (TRL) of solar sail propulsion from 3 towards 6 by the year 2006. Component and subsystem fabrication and testing were completed successfully, including the ground deployment of 10-meter and 20-meter demonstration hardware systems under vacuum conditions. The deployment and structural testing of the 20-meter solar sail systems was conducted in the 30 meter diameter Space Power Facility thermal-vacuum chamber at NASA Glenn Plum Brook in April though August, 2005. This paper will present the results of the TRL assessment following the solar sail technology development activities associated with the design, development, analysis and testing of the 20-meter system ground demonstrators.

  1. Solar concentrator panel and gore testing in the JPL 25-foot space simulator

    Science.gov (United States)

    Dennison, E. W.; Argoud, M. J.

    1981-01-01

    The optical imaging characteristics of parabolic solar concentrator panels (or gores) have been measured using the optical beam of the JPL 25-foot space simulator. The simulator optical beam has been characterized, and the virtual source position and size have been determined. These data were used to define the optical test geometry. The point source image size and focal length have been determined for several panels. A flux distribution of a typical solar concentrator has been estimated from these data. Aperture photographs of the panels were used to determine the magnitude and characteristics of the reflecting surface errors. This measurement technique has proven to be highly successful at determining the optical characteristics of solar concentrator panels.

  2. Indoor tests to investigate the effect of brine depth on the performance of solar still

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Marwah A.W.; Jabbar N. Khalifa, Abdul [Nahrain University, College of Engineering, Jadiriya, P.O. Box 64040, Baghdad (Iraq)

    2013-07-01

    Many experimental and numerical studies have been done on different configurations of solar stills to optimize the design by examining the effect of climatic, operational and design parameters on its performance. One of the most important of the operational parameters that has received a considerable attention in the literature is the brine depth. This paper reports indoor experimental investigations on the effect of brine depth on the productivity and efficiency of the solar stills at four different brine depths of 1.5, 2, 4 and 5.5 cm. Indoor tests were used by simulating the solar input by proper electric heaters located at the bottom of the still for heating the water contained in the basin of the still. The present study validated the decreasing trend in productivity with the increase of brine depth and showed that the still productivity could be influenced by the brine depth by up to 24%.

  3. Test reference year generation from meteorological and simulated solar radiation data

    Energy Technology Data Exchange (ETDEWEB)

    Miguel, A. de; Bilbao, J. [University of Valladolid (Spain). Dept. of Applied Physics

    2005-06-01

    In this paper, a new method for generating test reference year (TRY) from the measured meteorological variables is proposed. Hourly recorded data of air temperature, relative humidity and wind velocity for two stations, Valladolid and Madrid (Spain) were selected to develop the method and a TRY was obtained. Monthly average solar radiation values were calculated taking into account the temperature and solar radiation correlations. Four different methodologies were used to evaluate hourly global solar radiation from hourly weather data of temperature and, as a consequence, four different TRYs with common data sets of temperature, relative humidity and wind velocity were generated for Valladolid and Madrid (Spain) stations. In order to evaluate the four different methodologies, TRYs data were compared with long-term measured data series using statistical estimators such as average, standard deviation, root mean square error (rmse) and mean bias error (mbe). Festa and Ratto and the TAG model, from Aguiar and Collares-Pereira, respectively, turned out to be the best methods for generating hourly solar irradiation data. The best performance was shown by the TRY0 year which was based on the solar radiation models mentioned above. The results show that the best reference year for each site varies with the season and the characteristics of the station. (author)

  4. High Voltage Solar Array Arc Testing for a Direct Drive Hall Effect Thruster System

    Science.gov (United States)

    Schneider, Todd; Carruth, M. R., Jr.; Vaughn, J. A.; Jongeward, G. A.; Mikellides, I. G.; Ferguson, D.; Kerslake, T. W.; Peterson, T.; Snyder, D.; Hoskins, A.

    2004-01-01

    The deleterious effects of spacecraft charging are well known, particularly when the charging leads to arc events. The damage that results from arcing can severely reduce system lifetime and even cause critical system failures. On a primary spacecraft system such as a solar array, there is very little tolerance for arcing. Motivated by these concerns, an experimental investigation was undertaken to determine arc thresholds for a high voltage (200-500 V) solar array in a plasma environment. The investigation was in support of a NASA program to develop a Direct Drive Hall-Effect Thruster (D2HET) system. By directly coupling the solar array to a Hall-effect thruster, the D2HET program seeks to reduce mass, cost and complexity commonly associated with the power processing in conventional power systems. In the investigation, multiple solar array technologies and configurations were tested. The cell samples were biased to a negative voltage, with an applied potential difference between them, to imitate possible scenarios in solar array strings that could lead to damaging arcs. The samples were tested in an environment that emulated a low-energy, HET-induced plasma. Short duration trigger arcs as well as long duration sustained arcs were generated. Typical current and voltage waveforms associated with the arc events are presented. Arc thresholds are also defined in terms of voltage, current and power. The data will be used to propose a new, high-voltage (greater than 300 V) solar array design for which the likelihood of damage from arcing is minimal.

  5. Housing culture

    DEFF Research Database (Denmark)

    Roesdahl, Else; Scholkmann, Barbara

    2007-01-01

    On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies.......On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies....

  6. Innova House - Ottawa`s advanced house

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-31

    A pilot program was developed to provide the housing industry with a means to field test innovative technologies, products and building systems, and to evaluate their overall performance. Under Canada`s Advanced House Program, ten demonstration houses were designed, built and monitored. Ottawa`s Innova House, was one of the ten houses built for this program. The innovative energy saving features of the house included (1) air distribution with small diameter ducts and an electronically commutated motor, a 2.6 kW grid-connected photovoltaic system, (3) an energy recovery ventilator (ERV) with free-cooling mode, (4) a 94 per cent efficient integrated gas heating and hot water system, (5) airtight drywall construction, (6) CFC-free exterior insulation, (7) a natural-gas-engine heat pump for air conditioning, (8) a prototype sealed combustion gas range and clothes dryer, and (9) a manifold plumbing system to conserve water. It was designed to consume one half of the energy consumed in an R-2000 home and one third of the energy of a conventional house. Several of the mechanical elements did not perform at expected levels, (lower than expected efficiencies from the heating and cooling systems and a malfunctioning ERV), nevertheless, overall performance of the house was still very close to the targets. The construction and operation of the house was described. tabs., figs.

  7. Follow-up durability measurements and mitigation-performance improvement tests in 38 Eastern Pennsylvania houses having indoor radon-reduction systems. Final report, Oct 89-Feb 90

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1991-03-01

    The report gives results of follow-up tests in 38 difficult-to-mitigate Pennsylvania houses where indoor radon reduction systems had been installed 2 to 4 years earlier. Objectives were to assess system durability, methods for improving performance, and methods for reducing installation and operating costs. The durability tests indicated that the 38 systems have not experienced any significant degradation in indoor radon levels or in system flows/suctions, except in 6 houses where system fans failed, and in houses where homeowners turned off the systems. Tests to improve performance indicated that nearly all of the elevated residual radon levels are due to re-entrainment back into the house of very-high-radon exhaust gas from the soil depressurization systems, and to radon release from well water. Tests to reduce system costs showed that premitigation sub-slab suction field measurements can help prevent installation of too many suction pipes when communication is good, but suggest a need for too many pipes when communication is poor. Soil depressurization fans could not be turned down to the extent expected in some systems that were over-designed. Between 6 and 42% of the exhausted air was withdrawn from the house

  8. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, Michael W [Pratt & Whitney Rocketdyne; Miner, Kris [Pratt & Whitney Rocketdyne

    2013-03-30

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to

  9. Solar cell contact pull strength as a function of pull-test temperature

    Science.gov (United States)

    Yasui, R. K.; Berman, P. A.

    1972-01-01

    Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

  10. Standard Test Method for Solar Transmittance (Terrestrial) of Sheet Materials Using Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1986-01-01

    1.1 This test method covers the measurement of solar transmittance (terrestrial) of materials in sheet form by using a pyranometer, an enclosure, and the sun as the energy source. 1.2 This test method also allows measurement of solar transmittance at angles other than normal incidence. 1.3 This test method is applicable to sheet materials that are transparent, translucent, textured, or patterned. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Accelerated Lifetime Testing of Organic-Inorganic Perovskite Solar Cells Encapsulated by Polyisobutylene.

    Science.gov (United States)

    Shi, Lei; Young, Trevor L; Kim, Jincheol; Sheng, Yun; Wang, Lei; Chen, Yifeng; Feng, Zhiqiang; Keevers, Mark J; Hao, Xiaojing; Verlinden, Pierre J; Green, Martin A; Ho-Baillie, Anita W Y

    2017-08-02

    Metal halide perovskite solar cells (PSCs) have undergone rapid progress. However, unstable performance caused by sensitivity to environmental moisture and high temperature is a major impediment to commercialization of PSCs. In the present work, a low-temperature, glass-glass encapsulation technique using high performance polyisobutylene (PIB) as the moisture barrier is investigated on planar glass/FTO/TiO 2 /FAPbI 3 /PTAA/gold perovskite solar cells. PIB was applied as either an edge seal or blanket layer. Electrical connections to the encapsulated PSCs were provided by either the FTO or Au layers. Results of a "calcium test" demonstrated that a PIB edge-seal effectively prevents moisture ingress. A shelf life test was performed and the PIB-sealed PSC was stable for at least 200 days. Damp heat and thermal cycling tests, in compliance with IEC61215:2016, were used to evaluate different encapsulation methods. Current-voltage measurements were performed regularly under simulated AM1.5G sunlight to monitor changes in PCE. The best results we have achieved to date maintained the initial efficiency after 540 h of damp heat testing and 200 thermal cycles. To the best of the authors' knowledge, these are among the best damp heat and thermal cycle test results for perovskite solar cells published to date. Given the modest performance of the cells (8% averaged from forward and reverse scans) especially with the more challenging FAPbI 3 perovskite material tested in this work, it is envisaged that better stability results can be further achieved when higher performance perovskite solar cells are encapsulated using the PIB packaging techniques developed in this work. We propose that heat rather than moisture was the main cause of our PSC degradation. Furthermore, we propose that preventing the escape of volatile decomposition products from the perovskite solar cell materials is the key for stability. PIB encapsulation is a very promising packaging solution for perovskite

  12. Performance test of solar energy distillation system; Taiyonetsu riyo kaisui tansuika system no zosui seino shiken

    Energy Technology Data Exchange (ETDEWEB)

    Kawahara, T; Toyoshima, Y [Keio University, Tokyo (Japan); Narasaki, Y; Kamiya, I [Ebara Corp., Tokyo (Japan); Sato, H [Keio University, Tokyo (Japan). Faculty of Science and Technology

    1997-11-25

    In order to develop a seawater desalination equipment utilizing solar heat, a performance test was performed on a three-stage solar heat vacuum distiller. The equipment can evaporate and condense water at low temperatures by reducing the pressure in a distilling section. Solar heat is collected by a heat collecting plate, by which water as the working fluid is evaporated and moved to a heat conducting section in an evaporation pipe in a state of steam. The steam is condensed in a low-temperature heat conducting pipe, the heat is released outside the heat conducting pipe, and seawater is evaporated under low pressure condition. The working fluid is circulated for repetitive use. Solar cells are used as a motive power source for a vacuum pump, hence the system is self-sustainable even if installed in a desert area and the like places. The construction is simple, highly durable, and easy in maintenance. The system has high water producing performance, uses no harmful substances whatsoever such as fluorocarbons, and is a friendly system to the global environment. Because of evaporation at low temperatures, heat loss to the surroundings and sensible heat due to temperature rise are small, and the system response is quick. The solar heat can be utilized more effectively as multiple effects. When a heat collecting plate of 7.76 m {sup 2} was used, maximum yield of 105.45 kg/day was obtained. The system`s distillation efficiency is higher than other types of solar heat utilizing distillers. 7 refs., 5 figs.

  13. Displacement Damage Effects in Solar Cells: Mining Damage From the Microelectronics and Photonics Test Bed Space Experiment

    Science.gov (United States)

    Hardage, Donna (Technical Monitor); Walters, R. J.; Morton, T. L.; Messenger, S. R.

    2004-01-01

    The objective is to develop an improved space solar cell radiation response analysis capability and to produce a computer modeling tool which implements the analysis. This was accomplished through analysis of solar cell flight data taken on the Microelectronics and Photonics Test Bed experiment. This effort specifically addresses issues related to rapid technological change in the area of solar cells for space applications in order to enhance system performance, decrease risk, and reduce cost for future missions.

  14. Preliminary temperature Accelerated Life Test (ALT) on III-V commercial concentrator triple-junction solar cells

    OpenAIRE

    Espinet González, Pilar; Algora del Valle, Carlos; Orlando Carrillo, Vincenzo; Nuñez Mendoza, Neftali; Vázquez López, Manuel; Bautista Villares, Jesus; Xiugang, He; Barrutia Poncela, Laura; Rey-Stolle Prado, Ignacio; Araki, Kenji

    2012-01-01

    A quantitative temperature accelerated life test on sixty GaInP/GaInAs/Ge triple-junction commercial concentrator solar cells is being carried out. The final objective of this experiment is to evaluate the reliability, warranty period, and failure mechanism of high concentration solar cells in a moderate period of time. The acceleration of the degradation is realized by subjecting the solar cells at temperatures markedly higher than the nominal working temperature under a concentrator Three e...

  15. Testing the Solar Probe Cup, an Instrument Designed to Touch the Sun

    Science.gov (United States)

    Whittlesey, Phyllis L.; Case, Anthony W.; Kasper, Justin Christophe; Wright, Kenneth H., Jr.; Alterman, Ben; Cirtain, Jonathan W.; Bookbinder, Jay; Korreck, Kelly E.; Stevens, Michael Louis

    2014-01-01

    Solar Probe Plus will be the first, fastest, and closest mission to the sun, providing the first direct sampling of the sub-Alfvenic corona. The Solar Probe Cup (SPC) is a unique re-imagining of the traditional Faraday Cup design and materials for immersion in this high temperature environment. Sending an instrument of this type into a never-seen particle environment requires extensive characterization prior to launch to establish sufficient measurement accuracy and instrument response. To reach this end, a slew of tests for allowing SPC to see ranges of appropriate ions and electrons, as well as a facility that reproduces solar photon spectra and fluxes for this mission. Having already tested the SPC at flight like temperatures with no significant modification of the noise floor, we recently completed a round of particle testing to see if the deviations in Faraday Cup design fundamentally change the operation of the instrument. Results and implications from these tests will be presented, as well as performance comparisons to cousin instruments such as those on the WIND spacecraft.

  16. Solar energy

    International Nuclear Information System (INIS)

    Kruisheer, N.

    1992-01-01

    In five brief articles product information is given on solar energy applications with special attention to the Netherlands. After an introduction on solar energy availability in the Netherlands the developments in solar boiler techniques are dealt with. Solar water heaters have advantages for the environment, and government subsidies stimulate different uses of such water heaters. Also the developments of solar cells show good prospects, not only for developing countries, but also for the industrialized countries. In brief the developments in solar energy storage and the connection of solar equipment to the grid are discussed. Finally attention is paid to the applications of passive solar energy in the housing construction, the use of transparent thermal insulation and the developments of translucent materials. 18 figs., 18 ills

  17. Ground test program for a full-size solar dynamic heat receiver

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.

    1991-01-01

    Test hardware, facilities, and procedures were developed to conduct ground testing of a full-size, solar dynamic heat receiver in a partially simulated, low earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment was designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed-Brayton cycle engine simulator to circulate and condition the helium-xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.

  18. Local tests of gravitation with Gaia observations of Solar System Objects

    Science.gov (United States)

    Hees, Aurélien; Le Poncin-Lafitte, Christophe; Hestroffer, Daniel; David, Pedro

    2018-04-01

    In this proceeding, we show how observations of Solar System Objects with Gaia can be used to test General Relativity and to constrain modified gravitational theories. The high number of Solar System objects observed and the variety of their orbital parameters associated with the impressive astrometric accuracy will allow us to perform local tests of General Relativity. In this communication, we present a preliminary sensitivity study of the Gaia observations on dynamical parameters such as the Sun quadrupolar moment and on various extensions to general relativity such as the parametrized post-Newtonian parameters, the fifth force formalism and a violation of Lorentz symmetry parametrized by the Standard-Model extension framework. We take into account the time sequences and the geometry of the observations that are particular to Gaia for its nominal mission (5 years) and for an extended mission (10 years).

  19. Development and testing of shingle-type solar cell modules. Quarterly report No. 2

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, N.F.

    1978-01-05

    The details of a shingle module design which produces in excess of 97 watts/m/sup 2/ of module area at 1 kW/m/sup 2/ insolation and at 60/sup 0/C are reported. This selected design employs a tempered glass coverplate to provide the primary solar cell structural support. The use of the B.F. Goodrich FLEXSEAL roofing system as the outer skin of the shingle substrate provides a high confidence of achieving the 15 year service life goal. The fabrication and testing of a preproduction module of this design has demonstrated that this selected approach will meet the environmental testing requirements imposed by the contract. Attempts to fabricate a preproduction module of an alternative design, which embeds the solar cell assembly within a methyl methacrylate casting, proved unsuccessful.

  20. Comparative parameters of solar cells for power generation: test stand implementation using DSP

    International Nuclear Information System (INIS)

    Álvarez López, Ramón Antonio; García Angarita, Maritza Andrea

    2014-01-01

    The technologies used in solar modules are distinguished mainly by th eenergy conversion efficiency. Consequently, the module selection is critic to the long term performance of photovoltaic generating facility. Therefore, the selection must be supported by experimental results obtained under a specific operation condition. The article implements an experimentally test for obtain the characteristic parameters of a solar module, we analyze the energy conversion efficiency and other correlated parameters that directly affect the performance of a photovoltaic generator. The results show that the use of a rapid prototyping system using open hardware, such as TMS320F28335 development kit makes it easy to build a test photovoltaic generation systems. Latter justified by the low cost of such devices and ease of programming. (author)

  1. Smart solar domestic hot water systems. Development and test; Intelligente solvarmeanlaeg. Udvikling og afproevning

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, E.; Knudsen, S.; Furbo, S.; Vejen, N.K.

    2001-07-01

    The purpose of the project described in this report is to develop and test smart solar domestic hot water systems (SDHW systems) where the energy supply from the auxiliary energy supply system is controlled in a flexible way fitted to the hot water consumption in such a way, that the SDHW systems are suitable for large as well as small hot water demands. In a smart SDHW system the auxiliary energy supply system is controlled in a smart way. The auxiliary energy supply system heats up the water in the hot water tank from the top and only the hot water volume needed by the consumers is heated. Further the water is heated immediately before tapping. The control system includes a number of temperature sensors which cover the temperatures in the auxiliary heated volume. Based on these temperatures the energy content in the hot water tank is calculated. Only water heated to a temperature above 50 deg. C contributes to the total energy content in the hot water tank. Furhter the control system includes a timer that only allows the auxiliary energy supply system to be active in certain time periods and only if the energy content in the hot water tank is lower than wanted. In this way the water in the tank is heated immediately before the expected time of tapping and only the hot water volume needed is heated. The report is divided into five main sections. The sections deals with: Developing and testing storage tanks, laboratory test of SDHW systems based on some of the developed storage tanks, validation of simulation programs for smart solar heating systems, optimisation of system design and control strategy and measurements on two smart SDHW systems installed in single family houses. In all the developed hot water tanks, attempt is made to heat the water in the tank from the top of the tank and not as in traditional tanks where the water is heated from the lowest level of the auxiliary energy supply system, normally a helix or a electrical heating element placed in the

  2. Standarized performance tests of collectors of solar thermal energy: A steel flat-plate collector with two transparent covers and a proprietary coating

    Science.gov (United States)

    1976-01-01

    Basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator are given. The collector was tested over ranges of inlet temperature and flux level.

  3. Testing, Performance and Reliability Evaluation of Charge Controllers for Solar Photovoltaic Home Lighting System in India

    OpenAIRE

    Adarsh Kumar; ChandraShekhar Sharma; Dr. Rajesh Kumar; Avinashkumar haldkar

    2016-01-01

    :Charge controller is the most important part of a Solar Photovoltaic Home LightingSystem (SPVHLS) which controls the charging ofbattery from photovoltaic (PV) module and discharging of battery through load. This paper analyzes testresults of fourteen charge controllers (CC) available in Indiaaccording to the Ministry of New and RenewableEnergy (MNRE) specification. The different parameters of charge controllers to be tested arebattery high voltage disconnect (HVD), lo...

  4. Energy performance of the low-energy house in Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    by ventilation heat recovery (90% efficiency) specially designed for arctic conditions, by using thicker insulation in walls (300 mm) and roof/floor (350 mm), and by using solar hot water heating (3250 kWh/year). The building is intended to enhance sustainability in the building sector in Greenland....... energy gain, efficient ventilation system with heat recovery and solar heating. In this paper the results of a calculation of the energy consumption of low-energy house is presented. The calculation was done using the program BSim2002 [1] and a new weather test reference year based on climatic data......The object of the low-energy house in Sisimiut in Greenland was to build a house with an energy consumption less than 80 kWh/m² corresponding to half the energy frame of the coming building code. Therefore the focus in this project has been on large insulation thicknesses, windows with high net...

  5. Solar Training Network and Solar Ready Vets

    Energy Technology Data Exchange (ETDEWEB)

    Dalstrom, Tenley Ann

    2016-09-14

    In 2016, the White House announced the Solar Ready Vets program, funded under DOE's SunShot initiative would be administered by The Solar Foundation to connect transitioning military personnel to solar training and employment as they separate from service. This presentation is geared to informing and recruiting employer partners for the Solar Ready Vets program, and the Solar Training Network. It describes the programs, and the benefits to employers that choose to connect to the programs.

  6. Electrostatic Discharge Testing of Carbon Composite Solar Array Panels for Use in the Jovian Environment

    Science.gov (United States)

    Green, Nelson W.; Dawson, Stephen F.

    2015-01-01

    NASA is currently considering a mission to investigate the moons of Jupiter. When designing a spacecraft for this type of mission, there are a number of engineering challenges, especially if the mission chooses to utilize solar arrays to provide the spacecraft power. In order for solar arrays to be feasible for the mission, their total mass needed to fit within the total budget for the mission, which strongly suggested the use of carbon composite facesheets on an aluminum core for the panel structure. While these composite structures are a good functional substitution for the metallic materials they replace, they present unique challenges when interacting with the harsh Jovian space environment. As a composite material, they are composed of more than one material and can show different base properties depending in differing conditions. Looking at the electrical properties, in an Earth-based environment the carbon component of the composite dominates the response of the material to external stimulus. Under these conditions, the structures strongly resembles a conductor. In the Jovian environment, with temperatures reaching 50K and under the bombardment from energetic electrons, the non-conducting pre-preg binding materials may come to the forefront and change the perceived response. Before selecting solar arrays as the baseline power source for a mission to Jupiter, the response of the carbon composites to energetic electrons while held at cryogenic temperatures needed to be determined. A series of tests were devised to exam the response of a sample solar array panel composed of an M55J carbon weave layup with an RS-3 pre-preg binder. Test coupons were fabricated and exposed to electrons ranging from 10 keV to 100 keV, at 1 nA/cm2, while being held at cryogenic temperatures. While under electron bombardment, electrical discharges were observed and recorded with the majority of discharges occurring with electron energies of 25 keV. A decrease in temperature to liquid

  7. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    International Nuclear Information System (INIS)

    Roibás-Millán, E; Alonso-Moragón, A; Jiménez-Mateos, A G; Pindado, S

    2017-01-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I–V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data. (paper)

  8. Testing solar panels for small-size satellites: the UPMSAT-2 mission

    Science.gov (United States)

    Roibás-Millán, E.; Alonso-Moragón, A.; Jiménez-Mateos, A. G.; Pindado, S.

    2017-11-01

    At present, the development of small-size satellites by universities, companies and research institutions has become usual practice, and is spreading rapidly. In this kind of project cost plays a significant role. One of the main areas are the assembly, integration and test (AIT) plans, which carry an associated cost for simulating environmental conditions. For instance, in the power subsystems test and, in particular, in the testing of solar panels, the irradiance and temperature conditions might be optimum so the performance of the system can be shown next to real operational conditions. To reproduce the environmental conditions in terms of irradiance, solar simulators are usually used, which carries an associated increase in cost for testing the equipment. The aim of this paper is to present an alternative and inexpensive way to perform AIT plans on spacecraft power subsystems, from a testing campaign performed using outdoor clean-sky conditions and an isolation system to protect the panels. A post-process of the measured data is therefore needed, taking into account the conditions in which the test has been accomplished. The I-V characteristics obtained are compared with a theoretical 1-diode/2-resistor equivalent electric circuit, achieving enough precision based solely on the manufacturer’s data.

  9. THE DISTRIBUTION OF CHLORPYRIFOS FOLLOWING A CRACK AND CREVICE TYPE APPLICATION IN THE U.S. EPA INDOOR AIR QUALITY TEST HOUSE

    Science.gov (United States)

    A study was conducted in the U.S. EPA Indoor Air Quality Test House to determine the spatial and temporal distribution of chlorpyrifos following a professional crack and crevice application in the kitchen. Following the application, measurements were made in the kitchen, den a...

  10. Solar combi system based on a mantle tank

    DEFF Research Database (Denmark)

    Yazdanshenas, Eshagh; Furbo, Simon

    2007-01-01

    A solar combisystem based on a mantle tank is investigated numerically and experimentally. Three different houses with four different radiator systems are considered for the simulations. The needed temperature for the auxiliary heater is determined for different houses and radiator systems....... The thermal performance of the solar combisystem is compared to the thermal performance of a solar domestic hot water system based on a mantle tank. In the experimental study, tank temperatures and the heat transfer coefficient for the top mantle for a discharge test is determined. The investigations showed...

  11. Test results on parabolic dish concentrators for solar thermal power systems

    Science.gov (United States)

    Jaffe, Leonard D.

    1989-01-01

    This paper presents results of development testing of various solar thermal parabolic dish concentrators. The concentrators were mostly designed for the production of electric power using dish-mounted Rankine, Brayton or Stirling cycle engines, intended to be produced at low cost. Measured performance for various dishes included optical efficiencies ranging from 0.32 to 0.86 at a geometric concentration ratio of 500, and from about 0.09 to 0.85 at a geometric concentration ratio of 3000. Some malfunctions were observed. The tests should provide operating information of value in developing concentrators with improved performance and reduced maintenance.

  12. The Index House

    International Nuclear Information System (INIS)

    Reilly, M.A.

    1990-01-01

    This paper reports on the Pennsylvania Radon Research and Demonstration Project. The project involved the monitoring of the Index House for indoor radon, and was one of the earliest programs involving indoor radon contamination. The history of the house, the investigation, and testing and remediation procedures are discussed

  13. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for new detached houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    R and D was made on solar systems for new detached houses, and design and construction of the experimental house were carried out. In system analysis, assessment of solar cooling/heating systems, improvement of a simulation model based on measured data, and improvement of cooling/heating systems by simulation were conducted. In development of equipment and materials for the experimental house, R and D was made on component materials, connection method and installation method on houses for vacuum glass tube type solar collectors, and a solar collector was fabricated. R and D was also made on combination of absorbent and coolant, drop type coolant generator and performance experiment for absorption refrigerators, and a refrigerator was fabricated. The experimental house is 2-stored RC wall construction of 79.94m{sup 2} in building area, and 133.26m{sup 2} in total floor area. From the viewpoint of energy saving, outside insulation, double window, and insulating rain shutter door were adopted. The newly developed vacuum glass tube type solar collector is applicable to existing houses because of its higher flexibility. (NEDO)

  14. Pre-Flight Dark Forward Electrical Testing of the Mir Cooperative Solar Array

    Science.gov (United States)

    Kerslake, Thomas W.; Scheiman, David A.; Hoffman, David J.

    1997-01-01

    The Mir Cooperative Solar Array (MCSA) was developed jointly by the United States (US) and Russia to provide approximately 6 kW of photovoltaic power to the Russian space station Mir. After final assembly in Russia, the MCSA was shipped to the NASA Kennedy Space Center (KSC) in the summer of 1995 and launched to Mir in November 1995. Program managers were concerned of the potential for MCSA damage during the transatlantic shipment and the associated handling operations. To address this concern, NASA Lewis Research Center (LERC) developed an innovative dark-forward electrical test program to assess the gross electrical condition of each generator following shipment from Russia. The use of dark test techniques, which allow the array to remain in the stowed configuration, greatly simplifies the checkout of large area solar arrays. MCSA dark electrical testing was successfully performed at KSC in July 1995 following transatlantic shipment. Data from this testing enabled engineers to quantify the effects of potential MCSA physical damage that would degrade on-orbit electrical performance. In this paper, an overview of the principles and heritage of photovoltaic array dark testing is given. The specific MCSA dark test program is also described including the hardware, software, testing procedures and test results. The current-voltage (4) response of both solar cell circuitry and by-pass diode circuitry was obtained. To guide the development of dark test hardware, software and procedures, a dedicated FORTRAN computer code was developed to predict the dark 4 responses of generators with a variety of feasible damage modes. By comparing the actual test data with the predictions, the physical condition of the generator could be inferred. Based on this data analysis, no electrical short-circuits or open-circuits were detected. This suggested the MCSA did not sustain physical damage that affected electrical performance during handling and shipment from Russia to the US. Good

  15. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for existing detached houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Kison kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-05-27

    This report describes the fiscal 1976 research result on solar cooling/heating and hot water supply systems for existing detached houses. In system analysis, various evaluation items of the primary experimental house to be constructed and the titled thermal system were determined, and its measurement/control online program was developed. In the R and D on equipment and materials, the performance of the vacuum collector prepared in last fiscal year was tested, and based on its result and study on optimum structure, the new prototype vacuum collector was fabricated. In the study on heat transfer and heat storage system equipment, the medium-scale latent heat type heat storage tank (1 x 10{sup 4}kcal in thermal capacity, 8 x 10{sup 3}kcal/h in thermal output) using ammonium alum was prepared. For a preventive mechanism against supercooling, reconsideration of structure of a crystal nucleus formation plate was necessary. In the study on refrigerator driven by Rankine cycle engine, the prototype compressor more than 3,000kcal/h in refrigeration capacity was fabricated. Construction of the experimental house and trial operation of the cooling/heating system were promoted. (NEDO)

  16. Accelerated/abbreviated test methods of the low-cost silicon solar array project. Study 4, task 3: Encapsulation

    Science.gov (United States)

    Kolyer, J. M.; Mann, N. R.

    1977-01-01

    Methods of accelerated and abbreviated testing were developed and applied to solar cell encapsulants. These encapsulants must provide protection for as long as 20 years outdoors at different locations within the United States. Consequently, encapsulants were exposed for increasing periods of time to the inherent climatic variables of temperature, humidity, and solar flux. Property changes in the encapsulants were observed. The goal was to predict long term behavior of encapsulants based upon experimental data obtained over relatively short test periods.

  17. Accelerated stress testing of thin film solar cells: Development of test methods and preliminary results

    Science.gov (United States)

    Lathrop, J. W.

    1985-01-01

    If thin film cells are to be considered a viable option for terrestrial power generation their reliability attributes will need to be explored and confidence in their stability obtained through accelerated testing. Development of a thin film accelerated test program will be more difficult than was the case for crystalline cells because of the monolithic construction nature of the cells. Specially constructed test samples will need to be fabricated, requiring committment to the concept of accelerated testing by the manufacturers. A new test schedule appropriate to thin film cells will need to be developed which will be different from that used in connection with crystalline cells. Preliminary work has been started to seek thin film schedule variations to two of the simplest tests: unbiased temperature and unbiased temperature humidity. Still to be examined are tests which involve the passage of current during temperature and/or humidity stress, either by biasing in the forward (or reverse) directions or by the application of light during stress. Investigation of these current (voltage) accelerated tests will involve development of methods of reliably contacting the thin conductive films during stress.

  18. The Solar Constant, Climate, and Some Tests of the Storage Hypothesis

    Science.gov (United States)

    Eddy, J. A.

    1984-01-01

    Activity related modulation of the solar constant can have practical consequences for climate only if storage is involved, as opposed to a detailed balance between sunspot blocking and facular reemission. Four empirical tests are considered that might distinguish between these opposing interpretations: monochromatic measurements of positive and negative flux; comparison of modelled and measured irradiance variations; the interpretation of secular trends in irradiance data; and the direct test of an anticipated signal in climate records of surface air temperature. The yet unanswered question of the role of faculae as possible reemitters of blocked radiation precludes a definitive answer, although other tests suggest their role to be minor, and that storage and an 11 year modulation is implicated. A crucial test is the behavior of the secular trend in irradiance in the declining years of the present activity cycle.

  19. An Alternative Corrosion Resistance Test Method for Solar Cells and Interconnection Materials Limiting the Number of Long-lasting and Expensive Damp-Heat Climate Chamber Tests

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.B.; Gouwen, R.J.; Veldman, D.; Bende, E.E.; Eerenstein, W. [ECN Solar Energy, Petten (Netherlands)

    2013-06-15

    Damp-heat testing of PV modules is a time-consuming process, taking months. We present an alternative test method: electrochemical noise (EcN) measurements. Data acquisition times vary between minutes for direct exposure to several tens of hours for encapsulated samples. EcN measurements are presented for several solar cell concepts and different environments. We have found that the degradation in damp-heat testing is proportional to the electrochemical noise signal. In conclusion, the electrochemical noise measurements are a fast, versatile tool to test the corrosion resistance of solar cells, which can be tested for different environments including encapsulation.

  20. Full-size solar dynamic heat receiver thermal-vacuum tests

    Science.gov (United States)

    Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.

    1991-01-01

    The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.

  1. The Trojan-Hilda-KBO connection: An observational test of solar system evolution models

    Science.gov (United States)

    Wong, I.; Brown, M. E.

    2017-12-01

    Over the past few decades, many theories have been devised to explain the observed solar system architecture. The current paradigm posits that a significant reorganization of the outer Solar System occurred after the end of planet formation. Specifically, it is hypothesized that Jupiter and Saturn crossed a mutual mean motion resonance, leading to a chaotic expansion of the ice giants' orbits that disrupted the large population of planetesimals situated further out. While the majority of these bodies were ejected from the Solar System, a fraction of them were retained as the present-day Kuiper Belt, while others were scattered inward and captured into resonances with Jupiter to become the Trojans and Hildas. Dynamical instability models invariably predict that Trojans, Hildas, and Kuiper Belt objects (KBOs) were sourced from the same primordial body of outer solar system planetesimals. Therefore, comparison of these minor body populations serves as one of the few available observational tests of our present understanding of solar system evolution. We present the results of a series of studies aimed at synthesizing a detailed picture of Trojans and related asteroid populations. By combining analyses of archival data with new photometric surveys, we have derived the first debiased color distributions of Trojans and KBOs and extended/refined our knowledge of their respective size distributions. In addition, we have explored the peculiar color bimodality attested in the Trojans, Hildas, and KBOs, which indicates the presence of two sub-populations. As part of our continuing efforts to characterize the surface composition of these bodies, we have also obtained new near-infrared spectra of Hildas for comparison with previously published spectra of Trojans covering the same wavelength region. We have utilized the full body of observations to formulate hypotheses regarding the formation, composition, and dynamical/chemical evolution of the primordial outer solar system

  2. Design and Testing of a Natural Convection Solar Tunnel Dryer for Mango

    Directory of Open Access Journals (Sweden)

    Isaac Nyambe Simate

    2017-01-01

    Full Text Available A natural convection solar tunnel dryer comprising three major units, a solar collector unit, a drying unit, and a vertical bare flat-plate chimney, was constructed. No-load tests with a horizontal configuration of air entry into the collector resulted in a bidirectional air flow in the dryer. To correct this undesirable situation, an air guide at the collector was incorporated to ensure that air entered in a vertical direction. To investigate its performance, drying experiments with mango were carried out at the University of Zambia, Department of Agricultural Engineering. Uncertainties in the parameters measured in the experiment were analysed and quantified. The results showed that, under solar radiation between 568.4 and 999.5 W/m2, air temperature of up to 65.8°C was attained at the collector unit. The average relative humidity values were 30.8%, 6.4%, and 8.4% for the ambient, collector, and drying unit, respectively. Under these conditions, mango with an initial moisture content of 85.5% (wet basis was dried to 13.0% (wet basis in 9.5 hours. The collector, drying, and pick-up efficiencies were found to be 24.7%, 12.8%, and 35.0%, respectively. The average temperature difference between the chimney air and ambient air was 12.1°C, and this was sufficient in driving the flow of air through the dryer.

  3. Correlation of skin test results and specific immunoglobulin E blood levels with nasal provocation testing for house-dust mite allergies.

    Science.gov (United States)

    Haxel, Boris R; Huppertz, Tilman; Boessert, Patrick; Bast, Florian; Fruth, Kai

    2016-01-01

    Allergen-specific immunotherapy for house-dust mite (HDM) allergies is associated with lower success rates when compared with similar treatments for other inhalant allergens, such as grass or birch. One reason might be the greater difficulty in diagnosing patients with assumed HDM allergies because symptoms occur perennially and may differ from those of a conventional allergic rhinitis. The aim of the study was to compare the different methods of diagnosis in patients with assumed HDM allergy. We performed a retrospective analysis of nasal provocation tests (NPT) from patients (n = 161) evaluated for Dermatophagoides pteronyssinus (n = 127) and Dermatophagoides farinae (n = 104) allergies, and compared the results with other allergen testing methods (skin-prick test [SPT], intracutaneous test, and allergen specific immunoglobulin E levels [sIgE] to detect sensitization). Receiver operating characteristic curves were used for the analyses and the areas under the curve were calculated. For D. pteronyssinus and D. farinae, 86 and 70 complete data files, respectively, were available. For both tested HDMs, the results of the receiver operating characteristic curves showed a significant correlation for SPT and sIgE, with the results of the NPT (area under the curve, 0.742 to 0.763) but not for the intracutaneous test. In patients with a positive SPT (≥3 mm), an allergy was confirmed by the NPT in 69% of cases for D. pteronyssinus and 71% for D. farinae. A positive sIgE result (ImmunoCAP class of ≥2) was verified by the NPT in 69% of cases (D. pteronyssinus) and 70% (D. farinae). The predictability value for a positive NPT result is best for SPT and sIgE. Nevertheless, even if the results of both test systems are combined, the positive predictive value that was achieved was only 0.77 for D. pteronyssinus and 0.69 for D. farinae. Therefore, in patients eligible for immunotherapy for HDM, an NPT should be performed before the start of the therapy to verify a clinically

  4. Apartment building built to passive-house standard with solar balanced ventilation system; Mehrfamilien-Passivhaus mit solarem Luftsystem. Lueftung/Luftheizung/WRG/Solarfassade an der Rychenbergstrasse, Winterthur - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Guetermann, A.

    2002-04-15

    This final report for the Swiss Federal Office of Energy (SFOE) deals with an apartment building in Winterthur, Switzerland, built to passive-house standards and equipped with a solar balanced ventilation system. The building and its convective solar facade are described, as are the fan-assisted, balanced ventilation systems used. The operation of the systems in winter, during transitional periods and in summer is discussed. Domestic hot water preparation is looked at. The energy balance of the building is examined, as is the economic viability of the energy systems. The building, its energy installations and the measurement concept used are considered in detail. Finally, the findings of the study are summarised and commented on.

  5. Performance analysis on natural energy autonomous house, HARBEMAN house; Shizen energy jiritsu house (HARBEMAN house) no simulation ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujino, T; Saito, T [Tohoku University, Sendai (Japan)

    1997-11-25

    Outlined herein are a procedure developed to simulate performance of an energy-autonomous (independent) solar house referred to as HARBEMAN HOUSE (HH) built in 1996 in City of Sendai, comparison between the simulated and observed results, and characteristics of the solar house. The house is equipped with a solar collector and sky radiator, both installed on the roof, the former facing south to collect solar energy and generate hot water whereas the latter facing north to radiate heat and generate cool water. Both are connected to an underground heat-insulated tank having a capacity of 31m{sup 3}, which stores hot or cool water to keep their conditions for extended periods. The solar system operates in heat- or cool-storage mode. In the heat-storage mode, quantity of heat stored increases, although at a slow rate, as tank capacity increases. In the cool-storage mode, on the other hand, quantity of cool stored increases in proportion to tank capacity. This is because solar energy is collected throughout the year whereas cooling by radiation is concentrated in early spring. Loss rate of heat stored increases as tank capacity increases, and the opposite trend is observed with cool stored. 12 refs., 7 figs., 2 tabs.

  6. Testing of PCM Heat Storage Modules with Solar Collectors as Heat Source

    DEFF Research Database (Denmark)

    Englmair, Gerald; Dannemand, Mark; Johansen, Jakob Berg

    2016-01-01

    A latent heat storage based on the phase change material Sodium Acetate Trihydrate (SAT) has been tested as part of a demonstration system. The full heat storage consisted of 4 individual modules each containing about 200 kg of sodium acetate trihydrate with different additives. The aim...... was to actively utilize the ability of the material to supercool to obtain long storage periods. The modules were charged with solar heat supplied by 22.4 m2 evacuated tubular collectors. The investigation showed that it was possible to fully charge one module within a period of 270 minutes with clear skies...

  7. The solar panels of the spacecraft Stardust are deployed before undergoing lighting test in the PHSF

    Science.gov (United States)

    1999-01-01

    In the Payload Hazardous Servicing Facility, workers look over the solar panels on the Stardust spacecraft that are deployed for lighting tests. Stardust is scheduled to be launched aboard a Boeing Delta II rocket from Launch Pad 17A, Cape Canaveral Air Station, on Feb. 6, 1999, for a rendezvous with the comet Wild 2 in January 2004. Stardust will use a substance called aerogel to capture comet particles flying off the nucleus of the comet, plus collect interstellar dust for later analysis. The collected samples will return to Earth in a sample return capsule to be jettisoned as it swings by Earth in January 2006.

  8. The monolithic multicell: a tool for testing material components in dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, H.; Gruszecki, T. [IVF Industrial Research and Development Corporation, Moelndal (Sweden); Bernhard, R. [IVF Industrial Research and Development Corporation, Moelndal (Sweden); The Royal Institute of Technology, Stockholm (Sweden). Center of Molcular Devices, Department of Chemistry; Haeggman, L.; Gorlov, M.; Boschloo, G.; Edvinsson, T.; Kloo, L.; Hagfeldt, A. [The Royal Institute of Technology, Stockholm (Sweden). Center of Molcular Devices, Department of Chemistry

    2006-07-01

    A multicell is presented as a tool for testing material components in encapsulated dye-sensitized solar cells. The multicell is based on a four-layer monolithic cell structure and an industrial process technology. Each multicell plate includes 24 individual well-encapsulated cells. A sulfur lamp corrected to the solar spectrum has been used to characterize the cells. Efficiencies up to 6.8% at a light-intensity of 1000 W/m{sup su2} (up to 7.5% at 250 W/m{sup 2}) have been obtained with an electrolyte solution based on {upsilon}-butyrolactone. Additionally, a promising long-term stability at cell efficiencies close to 5% at 1000 W/m{sup 2} has been obtained with an electrolyte based on glutaronitrile. The reproducibility of the cell performance before and after exposure to accelerated testing has been high. This means that the multicell can be used as an efficient tool for comparative performance and stability tests. (author)

  9. Numerical model for the thermal yield estimation of unglazed photovoltaic-thermal collectors using indoor solar simulator testing

    NARCIS (Netherlands)

    Katiyar, M.; van Balkom, M.W.; Rindt, C.C.M.; de Keizer, C.; Zondag, H.A.

    2017-01-01

    It is a common practice to test solar thermal and photovoltaic-thermal (PVT) collectors outdoors. This requires testing over several weeks to account for different weather conditions encountered throughout the year, which is costly and time consuming. The outcome of these tests is an estimation of

  10. Testing and evaluation of large-area heliostats for solar thermal applications

    Energy Technology Data Exchange (ETDEWEB)

    Strachan, J.W.; Houser, R.M.

    1993-02-01

    Two heliostats representing the state-of-the-art in glass-metal designs for central receiver (and photovoltaic tracking) applications were tested and evaluated at the National Solar Thermal Test Facility in Albuquerque, New Mexico from 1986 to 1992. These heliostats have collection areas of 148 and 200 m{sup 2} and represent low-cost designs for heliostats that employ glass-metal mirrors. The evaluation encompassed the performance and operational characteristics of the heliostats, and examined heliostat beam quality, the effect of elevated winds on beam quality, heliostat drives and controls, mirror module reflectance and durability, and the overall operational and maintenance characteristics of the two heliostats. A comprehensive presentation of the results of these and other tests is presented. The results are prefaced by a review of the development (in the United States) of heliostat technology.

  11. The Comparison of Drawing Family and the House-Tree-Person Test in Children with Addicted and Non-Addicted Parents

    Directory of Open Access Journals (Sweden)

    Marjan Shafiei

    2013-04-01

    Full Text Available Objective: This study is aimed at comparing results of the draw-a-family test and the house-tree-person test in the children with addicted and non-addicted parents. Method: This is a scientific-comparative study in which 50 children with addicted parents attending Tehran rehab centers and 50 children with non-addicted parents who were selected using the random cluster sampling method were measured by means of the draw-a-family test and the house-tree-person test. Findings: Results suggest that drawing indices in the are more in the house-tree-Person paintings and family drawings of the children with addicted parents in comparison to the non-addicted group, scoring higher in terms of the number of drawing indices such as depression and anxiety symptoms, weak self-esteem, and valuelessness. Conclusion: It can be said that the parents' drug abuse intensifies and expedites children's physical, affective and behavioral problems.

  12. Sodium reflux pool-boiler solar receiver on-sun test results

    Energy Technology Data Exchange (ETDEWEB)

    Andraka, C E; Moreno, J B; Diver, R B; Moss, T A [Oak Ridge National Lab., TN (United States)

    1992-06-01

    The efficient operation of a Stirling engine requires the application of a high heat flux to the relatively small area occupied by the heater head tubes. Previous attempts to couple solar energy to Stirling engines generally involved directly illuminating the heater head tubes with concentrated sunlight. In this study, operation of a 75-kW{sub t} sodium reflux pool-boiler solar receiver has been demonstrated and its performance characterized on Sandia's nominal 75-kW{sub t} parabolic-dish concentrator, using a cold-water gas-gap calorimeter to simulate Stirling engine operation. The pool boiler (and more generally liquid-metal reflux receivers) supplies heat to the engine in the form of latent heat released from condensation of the metal vapor on the heater head tubes. The advantages of the pool boiler include uniform tube temperature, leading to longer life and higher temperature available to the engine, and decoupling of the design of the solar absorber from the engine heater head. The two-phase system allows high input thermal flux, reducing the receiver size and losses, therefore improving system efficiency. The receiver thermal efficiency was about 90% when operated at full power and 800{degree}C. Stable sodium boiling was promoted by the addition of 35 equally spaced artificial cavities in the wetted absorber surface. High incipient boiling superheats following cloud transients were suppressed passively by the addition of small amounts of xenon gas to the receiver volume. Stable boiling without excessive incipient boiling superheats was observed under all operating conditions. The receiver developed a leak during performance evaluation, terminating the testing after accumulating about 50 hours on sun. The receiver design is reported here along with test results including transient operations, steady-state performance evaluation, operation at various temperatures, infrared thermography, x-ray studies of the boiling behavior, and a postmortem analysis.

  13. Simulating Large Area, High Intensity AM0 Illumination – Test Results from Bepicolombo and Solar Orbiter Qualification

    Directory of Open Access Journals (Sweden)

    Oberhüttinger C.

    2017-01-01

    Specifically, the following topics will be treated. Different methods like electrical performance, thermo-optical and external quantum efficiency measurements have been used to characterize the behaviour of the solar cells after illumination under these conditions. A special focus has been put on the electrical performance. A comparison to other solar cell qualification tests under solely UV radiation has been undertaken. The results have also been compared to a theoretical model. However, the paper will not cover only characterization results but will also give some insight in challenges experienced during the test execution itself. Deviating from other solar cell qualification tests, a representatively equipped photovoltaic assembly on carbon fibre reinforced cyanate has also been included. On these coupon segments, solar cell assemblies connected to shunt diodes and placed next to optical surface reflectors have been exposed to AM0 illumination to qualify the solar cells including their surroundings which therefore covers also contamination effects. Last but not least, first results from the Solar Orbiter qualification are presented. This test with additional 1000 hours and increased intensity has been completed recently.

  14. Design and testing of a separate-type lighting system using solar energy and cold-cathode fluorescent lamps

    International Nuclear Information System (INIS)

    Yang, J.-P.; Hsiao, H.-C.

    2007-01-01

    This paper presents a solar-powered lighting system, using cold-cathode fluorescent-lamps (CCFLs), with its battery-charging circuit and lamp-ignition circuit being separated so that its solar panels can be installed at any distance deemed necessary away from the lighting site in order to receive the maximum solar energy available. This system adopts the maximum-power point tracking (MPPT) method to control the power output of the solar panels and uses the zero-voltage switching (ZVS) DC-DC converter, as the charging circuit, to increase the panels' power generation efficiency and the charging circuit's conversion efficiency. The electronic ballast circuit for the CCFL is constructed with a half-bridge inverter, a resonant inductor, and a Rosen-type piezoelectric transformer, which forms a piezoelectric resonant-type inverter: to simplify the circuitry and to improve the power conversion efficiency, the ballast circuit is designed to directly step up the battery voltage in igniting the lamp. We also establish the transmission-parameter model for the piezoelectric resonant-type inverter to provide the base for the electric-power circuit design. Our experimental results indicate that the proposed system possesses some advantages, such as greater energy efficiency, circuitry simplicity, and so on, and is suitable for night lighting in house yards, parks and advertising panels

  15. Design and testing of a separate-type lighting system using solar energy and cold-cathode fluorescent lamps

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J.-P. [Department of Electrical Engineering, China Institute of Technology, Taipei, Taiwan 115, Taiwan (China)]. E-mail: april4120@tp.edu.tw; Hsiao, H.-C. [Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan 106, Taiwan (China)]. E-mail: hsiao@mouse.ee.ntust.edu.tw

    2007-01-15

    This paper presents a solar-powered lighting system, using cold-cathode fluorescent-lamps (CCFLs), with its battery-charging circuit and lamp-ignition circuit being separated so that its solar panels can be installed at any distance deemed necessary away from the lighting site in order to receive the maximum solar energy available. This system adopts the maximum-power point tracking (MPPT) method to control the power output of the solar panels and uses the zero-voltage switching (ZVS) DC-DC converter, as the charging circuit, to increase the panels' power generation efficiency and the charging circuit's conversion efficiency. The electronic ballast circuit for the CCFL is constructed with a half-bridge inverter, a resonant inductor, and a Rosen-type piezoelectric transformer, which forms a piezoelectric resonant-type inverter: to simplify the circuitry and to improve the power conversion efficiency, the ballast circuit is designed to directly step up the battery voltage in igniting the lamp. We also establish the transmission-parameter model for the piezoelectric resonant-type inverter to provide the base for the electric-power circuit design. Our experimental results indicate that the proposed system possesses some advantages, such as greater energy efficiency, circuitry simplicity, and so on, and is suitable for night lighting in house yards, parks and advertising panels.

  16. Evaluation of autologous serum skin test and skin prick test reactivity to house dust mite in patients with chronic spontaneous urticaria.

    Directory of Open Access Journals (Sweden)

    Zhiqiang Song

    Full Text Available BACKGROUND: Chronic spontaneous urticaria (CSU is a common skin disorder with etiology that is not well understood. METHODS: In this study, we evaluated the prevalence of autologous serum skin test (ASST and skin prick testing (SPT to house dust mite (HDM in 862 CSU cases in China. Clinical features, courses and treatment responses were also recorded. RESULTS: The prevalence of positive ASST was 46.3%, and patients aged 30-39 years had the highest positive rate (52.1%. Positive SPT to HDM was seen in 153 patients (17.7% with the highest positive rate (34.2% in patients aged 20 or less. Patients with positive ASST had higher urticaria activity scores (UAS (4.18±0.65 vs. 3.67±0.53 but lower positive rates of HDM (24.6% vs. 37.6%, as compared with those with negative ASST (odds ratio (OR 1.84, 95% CI 1.38-2.47. Patients could be categorized into four groups based on the results of ASST and SPT to HDM and patients with positive ASST and positive SPT to HDM had the highest disease activity scores, experienced higher frequencies of angioedema, diseases duration, and required higher dosage of loratadine every month, compared with other subgroups (P<0.0001. CONCLUSIONS: Patients with CSU showed varied responses of positive ASST and varied sensitivity to HDM, Patients with positive ASST and/or positive SPT had more disease activity compared with patients with negative ASST and/or negative SPT. Further classification can be made based on the result of SPT and ASST.

  17. COR1 Engineering Test Unit Measurements at the Mauna Loa Solar Observatory, September 2003

    Science.gov (United States)

    Thompson, William; Reginald, Nelson; Streander, Kim

    2003-01-01

    The COR1 Engineering Test Unit (ETU), which had been previously tested at the NCAR/HAO and NRL test facilities, was modified into an instrument capable of observing the Sun. It was then taken to the Mauna Loa Solar Observatory to observe the corona. The changes made to observe the Sun were as follows: 1. The plate scale was changed to accommodate the smaller Apogee camera. This change had already been made for the NRL tests. 2. The previous Oriel polarizer was replaced with a commercial Polarcor polarizer from Newport to be more flight-like. However, because of cost and availability considerations, this polarizer was smaller than those which will be used for flight. 3. A structure was placed around the back section of the instrument, to protect it from stray light. 4. A pointing spar borrowed from HAO was used to track the Sun. A few days into the test, it became evident that some artifacts were appearing in the data, and these artifacts were changing as the polarizer was rotated. It was decided to test two other polarizers, the Oriel polarizer which had been used in the previous tests at HAO and NRL, and a Nikon polarizer which was borrowed from a camera belonging to one of the observatory staff members. These three polarizers had much different qualities are shown.

  18. Standard Practice for Solar Simulation for Thermal Balance Testing of Spacecraft

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1973-01-01

    1.1 Purpose: 1.1.1 The primary purpose of this practice is to provide guidance for making adequate thermal balance tests of spacecraft and components where solar simulation has been determined to be the applicable method. Careful adherence to this practice should ensure the adequate simulation of the radiation environment of space for thermal tests of space vehicles. 1.1.2 A corollary purpose is to provide the proper test environment for systems-integration tests of space vehicles. An accurate space-simulation test for thermal balance generally will provide a good environment for operating all electrical and mechanical systems in their various mission modes to determine interferences within the complete system. Although adherence to this practice will provide the correct thermal environment for this type of test, there is no discussion of the extensive electronic equipment and procedures required to support systems-integration testing. 1.2 Nonapplicability—This practice does not apply to or provide inco...

  19. The Nordic Housing Enabler

    DEFF Research Database (Denmark)

    Helle, Tina; Slaug, Bjørn; Brandt, Åse

    2010-01-01

    This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of its inter-rater reliability when used in occupational therapy rating situations, involving occupational therapists, clients and their home environments. The instrument was translated...... from the original Swedish version of the Housing Enabler, and adapted according to accessibility norms and guidelines for housing design in Sweden, Denmark, Finland and Iceland. This iterative process involved occupational therapists, architects, building engineers and professional translators......, resulting in the Nordic Housing Enabler. For reliability testing, the sampling strategy and data collection procedures used were the same in all countries. Twenty voluntary occupational therapists, pair-wise but independently from each other, collected data from 106 cases by means of the Nordic Housing...

  20. Nordic Housing Enabler

    DEFF Research Database (Denmark)

    Helle, Tina; Brandt, Åse

    Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing. Tina Helle & Åse Brandt University of Lund, Health Sciences, Faculty of Medicine (SE) and University College Northern Jutland, Occupational Therapy department (DK......). Danish Centre for Assistive Technology. Abstract. For decades, accessibility to the physical housing environment for people with functional limitations has been of interest politically, professionally and for the users. Guidelines and norms on accessible housing design have gradually been developed......, however, the built environment shows serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from...

  1. Clay Houses

    Science.gov (United States)

    Pedro, Cathy

    2011-01-01

    In this article, the author describes a project designed for fourth-graders that involves making clay relief sculptures of houses. Knowing the clay houses will become a family heirloom makes this lesson even more worth the time. It takes three classes to plan and form the clay, and another two to underglaze and glaze the final products.

  2. Standard Test Methods for Solar Energy Transmittance and Reflectance (Terrestrial) of Sheet Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 These test methods cover the measurement of solar energy transmittance and reflectance (terrestrial) of materials in sheet form. Method A, using a spectrophotometer, is applicable for both transmittance and reflectance and is the referee method. Method B is applicable only for measurement of transmittance using a pyranometer in an enclosure and the sun as the energy source. Specimens for Method A are limited in size by the geometry of the spectrophotometer while Method B requires a specimen 0.61 m2 (2 ft2). For the materials studied by the drafting task group, both test methods give essentially equivalent results. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. Field test of thermoelectric generator using parabolic trough solar concentrator for power generation

    Science.gov (United States)

    Viña, Rommel R.; Alagao, Feliciano B.

    2018-03-01

    A 2.4587 square meter effective area cylindrical parabolic solar concentrator was fabricated. The trough concentrator is a 4-ft by 8-ft metal sheet with solar mirror film adhered on it and it is laid on a frame with steel tubes bent in a shape of a parabola. On the focal region of the parabolic trough is the 1.22-m by 0.10-m absorber plate made of copper and coated flat black. This plate served as high temperature reservoir of the eight equally spaced TEC1-12710T125 thermoelectric modules. On the cold side of the modules is a 2.5-in. by 1-in. rectangular aluminum tube with coolant flowing inside. The coolant loop included a direct contact cooling tower which maintained the module cold side assembly inlet temperature of about 28°C. Collector temperature was also kept below the 125°C module maximum operating temperature by controlling the effective area. This was accomplished by adjusting the reflector covering. Using a dummy load and with 8 modules in series, tests results indicated current readings up to 179.4 mA with a voltage of 10.6 VDC and 27% of reflector area or voltage reading up to 12.7 VDC with a current of 165 mA. A steady voltage of 12 VDC was achieved with the use of a voltage regulator. A voltage above 12 VDC will be required to charge a storage battery. Overall results showed the potential of thermoelectric generator (TEG) in combination with solar energy in power generation.

  4. Passive House Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Strom, I.; Joosten, L.; Boonstra, C. [DHV Sustainability Consultants, Eindhoiven (Netherlands)

    2006-05-15

    PEP stands for 'Promotion of European Passive Houses' and is a consortium of European partners, supported by the European Commission, Directorate General for Energy and Transport. In this working paper an overview is given of Passive House solutions. An inventory has been made of Passive House solutions for new build residences applied in each country. Based on this, the most common basic solutions have been identified and described in further detail, including the extent to which solutions are applied in common and best practice and expected barriers for the implementation in each country. An inventory per country is included in the appendix. The analysis of Passive House solutions in partner countries shows high priority with regard to the performance of the thermal envelope, such as high insulation of walls, roofs, floors and windows/ doors, thermal bridge-free construction and air tightness. Due to the required air tightness, special attention must be paid to indoor air quality through proper ventilation. Finally, efficient ((semi-)solar) heating systems for combined space and DHW heating still require a significant amount of attention in most partner countries. Other basic Passive House solutions show a smaller discrepancy with common practice and fewer barriers have been encountered in partner countries. In the next section, the general barriers in partner countries have been inventoried. For each type of barrier a suggested approach has been given. Most frequently encountered barriers in partner countries are: limited know-how; limited contractor skills; and acceptation of Passive Houses in the market. Based on the suggested approaches to overcoming barriers, this means that a great deal of attention must be paid to providing practical information and solutions to building professionals, providing practical training to installers and contractors and communication about the Passive House concept to the market.

  5. Study on photovoltaic cell laying scheme of solar house in architecture design%建筑设计中太阳能小屋光伏电池铺设方案研究

    Institute of Scientific and Technical Information of China (English)

    吴孟桃; 郑现菊

    2017-01-01

    In order to solve the photovoltaic cells laying problem existing in the photovoltaic building,a calculation model of the solar radiation amount of the tilted surface was constructed in consideration of the direct,reflected and scattered solar ra-diation. The laying material is selected reasonably to analyze and simulate the laying form of the specific house,so as to choose the optimal installation method of the photovoltaic cell. The type of the photovoltaic cell and connection way of the inverter are analyzed to calculate the investment cost and benefit. On the basis of the optimal laying scheme,a model of the solar photovoltaic house was designed to save the energy.%为解决光伏建筑中光伏电池铺设问题,考虑到太阳光的直射、反射和散射等三种辐射,建立了倾斜面上太阳辐射总量的计算模型.合理地选择铺设材料,对给定小屋的铺设形式作了分析与模拟,选取光伏电池的最优安装方式.分析光伏电池的类型和逆变器的连接方式,计算得到投资成本与收益.以最优铺设方案为基础设计太阳能光电小屋模型,达到节能目的.

  6. Long-term field test of solar PV power generation using one-axis 3-position sun tracker

    KAUST Repository

    Huang, B.J.; Ding, W.L.; Huang, Y.C.

    2011-01-01

    The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand

  7. Bi-Axial Solar Array Drive Mechanism: Design, Build and Environmental Testing

    Science.gov (United States)

    Scheidegger, Noemy; Ferris, Mark; Phillips, Nigel

    2014-01-01

    The development of the Bi-Axial Solar Array Drive Mechanism (BSADM) presented in this paper is a demonstration of SSTL's unique space manufacturing approach that enables performing rapid development cycles for cost-effective products that meet ever-challenging mission requirements: The BSADM is designed to orient a solar array wing towards the sun, using its first rotation axis to track the sun, and its second rotation axis to compensate for the satellite orbit and attitude changes needed for a successful payload operation. The tight development schedule, with manufacture of 7 Flight Models within 1.5 year after kick-off, is offset by the risk-reduction of using qualified key component-families from other proven SSTL mechanisms. This allowed focusing the BSADM design activities on the mechanism features that are unique to the BSADM, and having an Engineering Qualification Model (EQM) built 8 months after kick-off. The EQM is currently undergoing a full environmental qualification test campaign. This paper presents the BSADM design approach that enabled meeting such a challenging schedule, its design particularities, and the ongoing verification activities.

  8. Analysis and Testing of a Natural Convection Solar Dryer for the Tropics

    Directory of Open Access Journals (Sweden)

    A. O. Adelaja

    2013-01-01

    Full Text Available Solar dryers are imperative for the tropical and sub-Saharan African countries, which are faced with the duo challenges of inadequate electrical energy supply, which has severely limited the application of conventional refrigeration as a means of preservation of agricultural produce, and the need to make produce competitive in the international market. In this study, a cost-effective natural convection solar dryer was developed; the thermal and drying analyses were done and tested to obtain some performance evaluation parameters for the system in order to examine its efficiency and effectiveness by drying some plantain fillets. The collector and system efficiencies are found to be 46.4% and 78.73%, respectively, while a percentage moisture removal of 77.5% was achieved at the 20th hour in order to give final moisture contents of 15.75% in the product, which still maintained its integrity. With a cost of about $195.00, it has been affordable for the small- and medium-scale enterprises as well as for private use in domestic applications.

  9. Solar Energy Education. Home economics: teacher's guide. Field test edition. [Includes glossary

    Energy Technology Data Exchange (ETDEWEB)

    1981-06-01

    An instructional aid is provided for home economics teachers who wish to integrate the subject of solar energy into their classroom activities. This teacher's guide was produced along with the student activities book for home economics by the US Department of Energy Solar Energy Education. A glossary of solar energy terms is included. (BCS)

  10. Solar Energy Education. Social studies: activities and teacher's guide. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Solar energy information is made available to students through classroom instruction by way of the Solar Energy Education teaching manuals. In this manual solar energy, as well as other energy sources like wind power, is introduced by performing school activities in the area of social studies. A glossary of energy related terms is included. (BCS)

  11. CDBG Housing Activity

    Data.gov (United States)

    Department of Housing and Urban Development — CDBG activity related to housing, including multifamily rehab, housing services, code enforcement, operation and repair of foreclosed property and public housing...

  12. Developments, characterization and proton irradiation damage tests of AlN detectors for VUV solar observations

    Energy Technology Data Exchange (ETDEWEB)

    BenMoussa, A., E-mail: ali.benmoussa@stce.be [Solar Terrestrial Center of Excellence (STCE), Royal Observatory of Belgium, Circular Avenue 3, B-1180 Brussels (Belgium); Soltani, A.; Gerbedoen, J.-C [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), F-59652 Villeneuve d’Ascq (France); Saito, T. [Department of Environment and Energy, Tohoku Institute of Technology, 35-1, Yagiyama-Kasumi-cho, Taihaku-ku, Sendai, Miyagi 982-8577 (Japan); Averin, S. [Fryazino Branch of the Kotel’nikov Institute of Radioengineering and Electronics of Russian Academy of Sciences, 141190 Square Vvedenski 1, Fryazino, Moscow Region (Russian Federation); Gissot, S.; Giordanengo, B. [Solar Terrestrial Center of Excellence (STCE), Royal Observatory of Belgium, Circular Avenue 3, B-1180 Brussels (Belgium); Berger, G. [Catholic University of Louvain-la-Neuve, Chemin du Cyclotron 2, B-1348 Louvain la Neuve (Belgium); Kroth, U. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, D-10587 Berlin (Germany); De Jaeger, J.-C. [Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), F-59652 Villeneuve d’Ascq (France); Gottwald, A. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, D-10587 Berlin (Germany)

    2013-10-01

    For next generation spaceborne solar ultraviolet radiometers, innovative metal–semiconductor–metal detectors based on wurtzite aluminum nitride are being developed and characterized. A set of measurement campaigns and proton irradiation damage tests was carried out to obtain their ultraviolet-to-visible characterization and degradation mechanisms. First results on large area prototypes up to 4.3 mm diameter are presented here. In the wavelength range of interest, this detector is reasonably sensitive and stable under brief irradiation with a negligible low dark current (3–6 pA/cm{sup 2}). No significant degradation of the detector performance was observed after exposure to protons of 14.4 MeV energy, showing a good radiation tolerance up to fluences of 1 × 10{sup 11} protons/cm{sup 2}.

  13. White House

    Science.gov (United States)

    ... content Jump to navigation the WHITE HOUSE President Donald J. Trump Get in Touch Home Briefing Room From the ... For All Americans The Administration The Administration President Donald J. Trump Vice President Mike Pence First Lady Melania Trump ...

  14. Development of the solar array deployment and drive system for the XTE spacecraft

    Science.gov (United States)

    Farley, Rodger; Ngo, Son

    1995-01-01

    The X-ray Timing Explorer (XTE) spacecraft is a NASA science low-earth orbit explorer-class satellite to be launched in 1995, and is an in-house Goddard Space Flight Center (GSFC) project. It has two deployable aluminum honeycomb solar array wings with each wing being articulated by a single axis solar array drive assembly. This paper will address the design, the qualification testing, and the development problems as they surfaced of the Solar Array Deployment and Drive System.

  15. Conformal house

    DEFF Research Database (Denmark)

    Ryttov, Thomas Aaby; Sannino, Francesco

    2010-01-01

    fixed point. As a consistency check we recover the previously investigated bounds of the conformal windows when restricting to a single matter representation. The earlier conformal windows can be imagined to be part now of the new conformal house. We predict the nonperturbative anomalous dimensions...... at the infrared fixed points. We further investigate the effects of adding mass terms to the condensates on the conformal house chiral dynamics and construct the simplest instanton induced effective Lagrangian terms...

  16. Solar energy in Amersfoort, Netherlands

    International Nuclear Information System (INIS)

    Eijpe, H.A.

    1997-01-01

    For the first time in the world a newly to be built housing area (Nieuwland in Amersfoort, Netherlands) will be constructed, exclusively on the basis of sustainability. First, the use of three forms of solar energy conversion techniques (thermal solar energy, passive solar energy and photovoltaic energy) is going to be integrated in 50 rental houses. At the end of this century 10,000 m 2 of solar cells will be installed with a capacity of 1 MWp. 2 figs

  17. Design and testing of a uniformly solar energy TIR-R concentration lenses for HCPV systems.

    Science.gov (United States)

    Shen, S C; Chang, S J; Yeh, C Y; Teng, P C

    2013-11-04

    In this paper, total internal reflection-refraction (TIR-R) concentration (U-TIR-R-C) lens module were designed for uniformity using the energy configuration method to eliminate hot spots on the surface of solar cell and increase conversion efficiency. The design of most current solar concentrators emphasizes the high-power concentration of solar energy, however neglects the conversion inefficiency resulting from hot spots generated by uneven distributions of solar energy concentrated on solar cells. The energy configuration method proposed in this study employs the concept of ray tracing to uniformly distribute solar energy to solar cells through a U-TIR-R-C lens module. The U-TIR-R-C lens module adopted in this study possessed a 76-mm diameter, a 41-mm thickness, concentration ratio of 1134 Suns, 82.6% optical efficiency, and 94.7% uniformity. The experiments demonstrated that the U-TIR-R-C lens module reduced the core temperature of the solar cell from 108 °C to 69 °C and the overall temperature difference from 45 °C to 10 °C, and effectively relative increased the conversion efficiency by approximately 3.8%. Therefore, the U-TIR-R-C lens module designed can effectively concentrate a large area of sunlight onto a small solar cell, and the concentrated solar energy can be evenly distributed in the solar cell to achieve uniform irradiance and effectively eliminate hot spots.

  18. MPPT algorithm test on a photovoltaic emulating system constructed by a DC power supply and an indoor solar panel

    International Nuclear Information System (INIS)

    Zhou, Z.; Holland, P.M.; Igic, P.

    2014-01-01

    Highlights: • A novel PV emulator is constructed by using conventional solar panels with a DC power supply. • The proposed PV emulator is cost-effectiveness, relatively easy implementation. • The proposed PV emulator avoids the bandwidth problem associated with electronics PV emulators. • Indoor testing of MPPT algorithms and power converters avoids the dependency on solar irradiation. • The PV emulating system has been used for testing a P and O MPPT algorithm and a boost dc converter. - Abstract: In this paper a novel photovoltaic (PV) emulating scheme for testing maximum power point tracking (MPPT) algorithms and PV inverters has been proposed. It is constructed by the parallel connection of conventional solar panels with a DC power supply operating in current source mode. The advantages of the proposed scheme are cost-effectiveness, relatively easy implementation and indoor testing of MPPT algorithms and power converters avoiding weather and time of day dependency on solar irradiation levels. Furthermore, the proposed PV emulator avoids the bandwidth problem associated with the dc converter based PV emulating systems. Detailed circuit connection, parameters, electrical characteristics and mathematical model of the PV emulator are presented and discussed. Proposed PV emulating system has been used to test a boost DC/DC converter controlled by Perturb and Observe (P and O) MPPT algorithm. Test results confirmed the effectiveness of the proposed PV emulation system and all achieved results correspond well to the original designed values

  19. Building a sustainable future: Bioclimatic house

    Science.gov (United States)

    Gomez Mallen, Esther; Rivera Fusalba, Oriol

    2010-05-01

    The application of bioclimatic principles is a critical factor in reducing energy consumption and CO2 emissions. This poster develops a sequence of experiments and building working models in order to form students of secondary school and make progress towards real applications of new energy technologies. The activity has been carried out by 14 and 15-year-old students using a Power House building kit. Scientific method and Information and Communication Technologies (ICT) were used as an effective system of acquiring new knowledge. Students were asked to form cooperative groups. Firstly, each group had to choose the best location and orientation in the imaginary Dragon Island for the construction of the house. The house consisted of eight Styrofoam parts and one transparent plastic part. The Styrofoam parts formed the house structure (floor, walls and roof) with two interior chambers and the attached greenhouse. Once the house was assembled in a few steps, it was ready for the students to start adding more components. Students then conducted several experiments related to the heat and light energy of the Sun and the energy of the wind. Some of the experiments and building projects realized were: how to capture the Sun to heat the house by passive solar heating, how to collect the Sun's rays to heat water using a Sun Collector and how to extract electricity current from Sun Power station and from wind power plant. For most of the assays it was necessary to record the temperature and students used for that purpose a temperature sensor that comes with Multilog Pro, a portable, graphic data collection and analysis system. Groups of students were really engaged in the project and each of them ran a different test with the house. Finally they proved if their initial hypothesis was correct and they had to expose the results to the rest of the class members. Students demonstrated how we can transform and use renewable forms of energy. With the experiments students

  20. Surface disinfection tests with Salmonella and a putative indicator bacterium, mimicking worst-case scenarios in poultry houses

    DEFF Research Database (Denmark)

    Gradel, K.O.; Sayers, A.R.; Davies, R.H.

    2004-01-01

    Surface disinfection studies mimicking worst-case scenarios in badly cleaned poultry houses were made with 3 bacterial isolates (Salmonella enteritidis, Salmonella senftenberg, and Enterococcus faecalis), and 3 1% disinfectant solutions, formaldehyde (F; 24.5% vol/vol), glutaraldehyde...... hard water, except when feed chain links with fats were disinfected using 30degreesC before and after disinfection, for which the peroxygen compound seemed more effective. Enterococcus faecalis was equally or less susceptible than S. enteritidis and S. senftenberg, indicating its suitability...... as an indicator bacterium. For the peroxygen compound, S. senftenberg was more susceptible than S. enteritidis in spite of higher minimum inhibitory concentrations to this disinfectant for the former....

  1. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for existing detached houses); 1974 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Kison kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-28

    This report describes the fiscal 1974 research result on solar cooling/heating and hot water supply systems for existing detached houses. The program for calculating heat collection rates was prepared by integrating peripheral conditions and every calculation step of heat collection rate, mean value, accumulated value and changes caused by disturbance. The cooling/heating load calculation program was also prepared for unsteady dynamic thermal analysis of houses. Another program was prepared for hot water supply load because of a large difference in life pattern. The profitability and energy conservation of 644 systems different in heat source, heat discharge, heat collection, heat storage, auxiliary heat source and equipment were evaluated by heat balance calculation program. Survey and study were also made on various heat engines such as heat pump, absorption refrigerator and Rankine cycle engine. Based on the survey result on existing technology for plane collectors, the optimum design method of collectors were established through various characteristic tests. Some kinds of suitable fusion latent heat type heat media were selected, and their operation stabilities were studied. (NEDO)

  2. Environmentally Friendly Sustainable Housing Construction ...

    African Journals Online (AJOL)

    The major steps include 5 star standards in the state of Victoria, with rebates for sustainable products including solar hot water system, photovoltaic panels, rainwater tanks, grey water tanks and insulation. In addition phasing out of incandescent light bulbs is also encouraged. A number of house energy rating tools have ...

  3. Long-term ageing tests on glazing materials for solar collectors; Langzeit-Alterungsuntersuchung an Abdeckungsmaterialien fuer thermische Sonnenkollektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ruesch, F.; Brunold, S.; Haeuselmann, T.; Frank, E.; Frei, U.

    2008-02-15

    This report made by the Swiss Institute for Solar Technology at the University of Applied Sciences in Rapperswil, Switzerland, for Swiss Federal Office of Energy (SFOE) takes a look at the results of a project that investigated the long-term behaviour of glazing materials for solar collectors. The locations tested and their associated meteorological data are presented and the tests made concerning the optical characteristics of several different types of glazing are discussed. Soiling and degradation are also looked at. An overview of the solar transmission of the various materials is presented. Details on the various materials such as glass, polymethyl metacrylate (PMMA), polycarbonate (PC), fluorised plastics, unsaturated polyester (UP), polyvinyl chloride (PVC) and polyethylene terephthalate (PET) are presented.

  4. Solar system tests for realistic f(T) models with non-minimal torsion-matter coupling

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Rui-Hui; Zhai, Xiang-Hua; Li, Xin-Zhou [Shanghai Normal University, Shanghai United Center for Astrophysics (SUCA), Shanghai (China)

    2017-08-15

    In the previous paper, we have constructed two f(T) models with non-minimal torsion-matter coupling extension, which are successful in describing the evolution history of the Universe including the radiation-dominated era, the matter-dominated era, and the present accelerating expansion. Meantime, the significant advantage of these models is that they could avoid the cosmological constant problem of ΛCDM. However, the non-minimal coupling between matter and torsion will affect the tests of the Solar system. In this paper, we study the effects of the Solar system in these models, including the gravitation redshift, geodetic effect and perihelion precession. We find that Model I can pass all three of the Solar system tests. For Model II, the parameter is constrained by the uncertainties of the planets' estimated perihelion precessions. (orig.)

  5. An accelerated stress testing program for determining the reliability sensitivity of silicon solar cells to encapsulation and metallization systems

    Science.gov (United States)

    Lathrop, J. W.; Davis, C. W.; Royal, E.

    1982-01-01

    The use of accelerated testing methods in a program to determine the reliability attributes of terrestrial silicon solar cells is discussed. Different failure modes are to be expected when cells with and without encapsulation are subjected to accelerated testing and separate test schedules for each are described. Unencapsulated test cells having slight variations in metallization are used to illustrate how accelerated testing can highlight different diffusion related failure mechanisms. The usefulness of accelerated testing when applied to encapsulated cells is illustrated by results showing that moisture related degradation may be many times worse with some forms of encapsulation than with no encapsulation at all.

  6. French energy conservation policies in housing since 1973: an innovation put to the test of local practice

    Energy Technology Data Exchange (ETDEWEB)

    Bonaiti, J.P. (Inst. d' Economie et de Politique de l' Energie, Univ. des Science Sociales de Grenoble, France)

    1989-04-01

    In France, while government agencies were analyzing the process of formation of the conservation market in building construction, along with the various obstacles to decision making: passivity of private owners of apartment buildings, lack of information, fragmentation of supply, more innovative public sector housing authorities were discovering the need for an integrated campaign, assembling a package of all the components of energy conservation (investment, maintenance, education...) to attain maximum efficiency. Thus, the hypothesis was formulated that energy conservation is a complex product of technical and social innovation, or more precisely, a 'function', whose dissemination remains conditioned by the local situations, especially the structures and the methods of management of the housing stock. Then, fifteen programmes were observed and two types of strategies or processes identified: top-down (sector based) and local (area based). The first type was found to be very expensive, too generalized, pressuring, and arousing exagerated expectations. The second was considered more coherent and integrated to local policy (especially building retroffiting), more progressive and educative since it entailed an auditing approach differentiated to individual needs, and the presence of independant advisers. This last strategy seemed more efficient in the long term and on the whole more suited to a period of low energy prices.

  7. Solar water-heating performance evaluation-San Diego, California

    Science.gov (United States)

    1981-01-01

    Report describes energy saved by replacing domestic, conventional natural gas heater with solar-energy subsystem in single-family residence near San Diego, California. Energy savings for 6 month test period averaged 1.089 million Btu. Collector array covered 65 square feet and supplied hot water to both 66-gallon solar storage tank and 40-gallon tank for domestic use. Natural gas supplied house's auxiliary energy.

  8. Investigation of test methods, material properties, and processes for solar cell encapsulants. Annual report

    Energy Technology Data Exchange (ETDEWEB)

    Willis, P. B.; Baum, B.

    1979-06-01

    The goal of this program is to identify, evaluate, and recommend encapsulant materials and processes for the production of cost-effective, long-life solar cell modules. During the past year, the technical activities emphasized the reformulation of a commercial grade of ethylene/vinyl acetate copolymer for use as a pottant in solar cell module manufacture. After experimenting with a variety of techniques, a vacuum-bag process was developed and found to be an excellent encapsulation method. Adhesive strengths and primers for the bonding of ethylene/vinyl acetate to superstrate and substrate materials was assessed with encouraging results. The weathering effects on ten other polymers exposed to twelve months of weathering in Arizona, Florida, and under EMMAQUA were evaluated by determination of tensile strengths, elongations, optical transmission, etc. As may be expected, the best overall retention of mechanical properties is found for the fluorocarbon polymers, especially FEP. Hard coatings containing ultraviolet absorbers were investigated for the purpose of providing a soil resistant surface and additional weathering stability to the soft EVA pottant. Corrosion studies using a standard salt spray test were used to determine the degree of protection offered to a variety of metals by encapsulation in EVA pottant. A survey of scrim materials was also conducted. These open hole weaves are intended for use as spacers between the cell and substrate to provide a mechanical barrier, improve insulation resistance and prevent migration of the pigmented pottant over the cell surface. A mechanical engineering analysis of composite structural materials for use as substrates was performed. Results are presented in detail. (WHK)

  9. Test and evaluation of Fern Engineering Company, Incorporated, solar heating and hot water system. [structural design criteria and system effectiveness

    Science.gov (United States)

    1979-01-01

    Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.

  10. A new method to detect solar-like oscillations at very low S/N using statistical significance testing

    DEFF Research Database (Denmark)

    Lund, Mikkel N.; Chaplin, William J.; Kjeldsen, Hans

    2012-01-01

    hence a candidate detection). We apply the method to solar photometry data, whose quality was systematically degraded to test the performance of the MWPS at low signal-to-noise ratios. We also compare the performance of the MWPS against the frequently applied power-spectrum-of-power-spectrum (PSx...

  11. Three computer codes to read, plot, and tabulate operational test-site recorded solar data. [TAPFIL, CHPLOT, and WRTCNL codes

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, S.D.; Sampson, R.J. Jr.; Stonemetz, R.E.; Rouse, S.L.

    1980-07-01

    A computer program, TAPFIL, has been developed by MSFC to read data from an IBM 360 tape for use on the PDP 11/70. The information (insolation, flowrates, temperatures, etc.) from 48 operational solar heating and cooling test sites is stored on the tapes. Two other programs, CHPLOT and WRTCNL, have been developed to plot and tabulate the data. These data will be used in the evaluation of collector efficiency and solar system performance. This report describes the methodology of the programs, their inputs, and their outputs.

  12. Large-scale solar purchasing

    International Nuclear Information System (INIS)

    1999-01-01

    The principal objective of the project was to participate in the definition of a new IEA task concerning solar procurement (''the Task'') and to assess whether involvement in the task would be in the interest of the UK active solar heating industry. The project also aimed to assess the importance of large scale solar purchasing to UK active solar heating market development and to evaluate the level of interest in large scale solar purchasing amongst potential large scale purchasers (in particular housing associations and housing developers). A further aim of the project was to consider means of stimulating large scale active solar heating purchasing activity within the UK. (author)

  13. The Nordic Housing Enabler

    DEFF Research Database (Denmark)

    Helle, T.; Nygren, C.; Slaug, B.

    2014-01-01

    This study addresses development of a content-valid cross-Nordic version of the Housing Enabler and investigation of its inter-rater reliability when used in occupational therapy rating situations, involving occupational therapists, clients, and their home environments. The instrument was transla......This study addresses development of a content-valid cross-Nordic version of the Housing Enabler and investigation of its inter-rater reliability when used in occupational therapy rating situations, involving occupational therapists, clients, and their home environments. The instrument...... was translated from the original Swedish version of the Housing Enabler, and adapted according to accessibility norms and guidelines for housing design in Sweden, Denmark, Finland, and Iceland. This iterative process involved occupational therapists, architects, building engineers, and professional translators......, resulting in the Nordic Housing Enabler. For reliability testing, the sampling strategy and data collection procedures used were the same in all countries. Twenty voluntary occupational therapists, pair-wise but independently of each other, collected data from 106 cases by means of the Nordic Housing...

  14. URBox : High tech energy and informal housing

    NARCIS (Netherlands)

    Cuperus, Y.J.; Smets, D.

    2011-01-01

    This paper reports on the URBox concept encompassing the high tech end of solar energy and informal low cost and affordable housing. It aims to contribute to solving the global energy crisis by building solar energy settlements in deserts where land is affordable and sunshine in abundance. First the

  15. Solar Energy Education. Humanities: activities and teacher's guide. Field test edition

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    Activities are outlined to introduce students to information on solar energy while performing ordinary classroom work. In this teaching manual solar energy is integrated with the humanities. The activities include such things as stories, newspapers, writing assignments, and art and musical presentations all filled with energy related terms. An energy glossary is provided. (BCS)

  16. Financial analysis on the proposed renewable heat incentive for residential houses in the United Kingdom: A case study on the solar thermal system

    International Nuclear Information System (INIS)

    Abu-Bakar, Siti Hawa; Muhammad-Sukki, Firdaus; Ramirez-Iniguez, Roberto; Munir, Abu Bakar; Mohd Yasin, Siti Hajar; Mallick, Tapas Kumar; McLennan, Campbell; Abdul Rahim, Ruzairi

    2014-01-01

    This short communication paper focuses on the renewable heat incentive (RHI) scheme in the United Kingdom (UK); and in particular, on its implication on domestic installations of solar thermal systems (STSs). First, a short review on the STS in the UK is provided. Then, a detailed description of the RHI is discussed. A financial analysis is presented afterwards, analysing the impact of the RHI scheme on the applicants, in terms of the net present value and the internal rate of return. From the financial analysis it has been found that the RHI scheme for domestic installations is only attractive if a longer period of RHI payment, i.e. 17 years, or a higher RHI rate i.e. £0.32 per kW h is implemented. The current proposal from the UK government is not financially viable, and as a result, it may hinder the penetration of domestic solar thermal systems in the residential sector in the UK. - Highlights: • A short review on solar thermal system (STS) is presented. • The renewable heat incentive (RHI) scheme is discussed. • A financial analysis is evaluated under the RHI scheme in the UK. • The analysis indicates the current proposal is not desirable to consumers

  17. Standardized performance tests of collectors of solar thermal energy-a flat-plate collector with a single-tube serpentine flow distribution

    Science.gov (United States)

    Johnson, S.

    1976-01-01

    This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficienty is correlated in terms of inlet temperature and flux level.

  18. Investigation of Thermal Performance of Flat Plate and Evacuated Tubular Solar Collectors According to a New Dynamic Test Method

    DEFF Research Database (Denmark)

    Kong, Weiqiang; Wang, Zhifeng; Fan, Jianhua

    2012-01-01

    obtain fluid thermal capacitance in data processing. Then theoretical analysis and experimental verification are carried out to investigate influencing factors of obtaining accurate and stable second order term. A flat plate and ETC solar collector are compared using both the new dynamic method......A new dynamic test method is introduced. This so called improved transfer function method features on two new collector parameters. One is time term which can indicate solar collector's inner heat transfer ability and the other is a second order term of collector mean fluid temperature which can...... and a standard method. The results show that the improved function method can accurately and robustly estimate these two kinds of solar collectors....

  19. Active house

    DEFF Research Database (Denmark)

    Eriksen, Kurt Emil; Olesen, Gitte Gylling Hammershøj

    Formålet med dette abstrakt er at illustrere, at huse kan være konstrueret til at basere sig udelukkende på vedvarende energikilder og samtidig være CO2-neutrale og producere mere energi end de forbruger. Active House Visionen undersøger disse muligheder i otte demonstration huse i fem forskellige...

  20. Design, development and performance testing of a new natural convection solar dryer

    Energy Technology Data Exchange (ETDEWEB)

    Pangavhane, D.R. [K.K. Wagh College of Engineering, Nashik (India). Department of Mechanical Engineering; Sawhney, R.L.; Sarsavadia, P.N. [Devi Ahilya Vishwa Vidhyalaya, Indore (India). School of Energy and Environmental Studies

    2002-06-01

    Mechanical drying of agricultural products is an energy consuming operation in the post-harvesting technology. Greater emphasis is given to using solar energy sources in this process due to the high prices and shortages of fossil fuels. For these purposes, a new natural convection solar dryer consisting of a solar air heater and a drying chamber was developed. This system can be used for drying various agricultural products like fruits and vegetables. In this study, grapes were successfully dried in the developed solar dryer. The qualitative analysis showed that the traditional drying, i.e. shade drying and open sun drying, dried the grapes in 15 and 7 days respectively, while the solar dryer took only 4 days and produced better quality raisins. (author)

  1. Analysis of trends between solar wind velocity and energetic electron fluxes at geostationary orbit using the reverse arrangement test

    Science.gov (United States)

    Aryan, Homayon; Boynton, Richard J.; Walker, Simon N.

    2013-02-01

    A correlation between solar wind velocity (VSW) and energetic electron fluxes (EEF) at the geosynchronous orbit was first identified more than 30 years ago. However, recent studies have shown that the relation between VSW and EEF is considerably more complex than was previously suggested. The application of process identification technique to the evolution of electron fluxes in the range 1.8 - 3.5 MeV has also revealed peculiarities in the relation between VSW and EEF at the geosynchronous orbit. It has been revealed that for a constant solar wind density, EEF increase with VSW until a saturation velocity is reached. Beyond the saturation velocity, an increase in VSW is statistically not accompanied with EEF enhancement. The present study is devoted to the investigation of saturation velocity and its dependency upon solar wind density using the reverse arrangement test. In general, the results indicate that saturation velocity increases as solar wind density decreases. This implies that solar wind density plays an important role in defining the relationship between VSW and EEF at the geosynchronous orbit.

  2. Reconstructing solar magnetic fields from historical observations: Testing the surface flux transport model

    Science.gov (United States)

    Virtanen, Iiro; Virtanen, Ilpo; Pevtsov, Alexei; Yeates, Anthony; Mursula, Kalevi

    2017-04-01

    We aim to use the surface flux transport model to simulate the long-term evolution of the photospheric magnetic field from historical observations. In this work we study the accuracy of the model and its sensitivity to uncertainties in its main parameters and the input data. We test the model by running simulations with different values of meridional circulation and supergranular diffusion parameters, and study how the flux distribution inside active regions and the initial magnetic field affect the simulation. We compare the results to assess how sensitive the simulation is to uncertainties in meridional circulation speed, supergranular diffusion and input data. We also compare the simulated magnetic field with observations. We find that there is generally good agreement between simulations and observations. While the model is not capable of replicating fine details of the magnetic field, the long-term evolution of the polar field is very similar in simulations and observations. Simulations typically yield a smoother evolution of polar fields than observations, that often include artificial variations due to observational limitations. We also find that the simulated field is fairly insensitive to uncertainties in model parameters or the input data. Due to the decay term included in the model the effects of the uncertainties are rather minor or temporary, lasting typically one solar cycle.

  3. Design and testing of a solar photovoltaic operated multi-seeds oil press

    Energy Technology Data Exchange (ETDEWEB)

    Mpagalile, J.J. [Department of Food Science and Technology, Sokoine University of Agriculture, P.O. Box 3006, Morogoro (Tanzania); Hanna, M.A.; Weber, R. [Industrial Agricultural Products Center, University of Nebraska, 209 L.W. Chase Hall, Lincoln, NE 68583-0730 (United States)

    2006-10-15

    Oil expression tests were conducted to evaluate the performance of a novel oil expeller designed and fabricated to operate on a 200W solar photovoltaic (PV) power system as a sole power source. The oil press was designed to press oilseeds meal with intermediate moisture content of 12+/-1% (w.b.) and 0.5-2mm particle sizes. Freshly grated coconuts and ground peanuts were used to determine the oil expression efficiency of the press. The oilseed samples were pressed for 12min with a maximum pressure of 3.0MPa being reached at 6min of pressing for peanuts and 8min of pressing for coconuts. The pressure was then held for the rest of the pressing time. The press attained an average oil expression efficiency of 73% for coconuts and 70% for peanuts. The force-vs.-deformation studies indicated that peanut press meal was compacted at a higher rate as compared to coconuts. The observation on the energy consumption indicated that there was a significant increase (P<0.05) in the specific energy requirement for both coconuts and peanuts after 6min of pressing, which resulted from the solidification of the press cake. An average specific energy of 36.55 and 20.35Wh/kg was recorded for peanuts and coconuts, respectively, after 12min of pressing. (author)

  4. Software used with the flux mapper at the solar parabolic dish test site

    Science.gov (United States)

    Miyazono, C.

    1984-01-01

    Software for data archiving and data display was developed for use on a Digital Equipment Corporation (DEC) PDP-11/34A minicomputer for use with the JPL-designed flux mapper. The flux mapper is a two-dimensional, high radiant energy scanning device designed to measure radiant flux energies expected at the focal point of solar parabolic dish concentrators. Interfacing to the DEC equipment was accomplished by standard RS-232C serial lines. The design of the software was dicated by design constraints of the flux-mapper controller. Early attemps at data acquisition from the flux-mapper controller were not without difficulty. Time and personnel limitations result in an alternative method of data recording at the test site with subsequent analysis accomplished at a data evaluation location at some later time. Software for plotting was also written to better visualize the flux patterns. Recommendations for future alternative development are discussed. A listing of the programs used in the anaysis is included in an appendix.

  5. Reconstructing solar magnetic fields from historical observations. II. Testing the surface flux transport model

    Science.gov (United States)

    Virtanen, I. O. I.; Virtanen, I. I.; Pevtsov, A. A.; Yeates, A.; Mursula, K.

    2017-07-01

    Aims: We aim to use the surface flux transport model to simulate the long-term evolution of the photospheric magnetic field from historical observations. In this work we study the accuracy of the model and its sensitivity to uncertainties in its main parameters and the input data. Methods: We tested the model by running simulations with different values of meridional circulation and supergranular diffusion parameters, and studied how the flux distribution inside active regions and the initial magnetic field affected the simulation. We compared the results to assess how sensitive the simulation is to uncertainties in meridional circulation speed, supergranular diffusion, and input data. We also compared the simulated magnetic field with observations. Results: We find that there is generally good agreement between simulations and observations. Although the model is not capable of replicating fine details of the magnetic field, the long-term evolution of the polar field is very similar in simulations and observations. Simulations typically yield a smoother evolution of polar fields than observations, which often include artificial variations due to observational limitations. We also find that the simulated field is fairly insensitive to uncertainties in model parameters or the input data. Due to the decay term included in the model the effects of the uncertainties are somewhat minor or temporary, lasting typically one solar cycle.

  6. Design development and testing of a solar PV pump based drip system for orchards

    Energy Technology Data Exchange (ETDEWEB)

    Pande, P.C.; Singh, A.K.; Ansari, S.; Vyas, S.K.; Dave, B.K. [Central Arid Zone Research Inst., Jodhpur (India)

    2003-03-01

    A Solar Photovoltaic (PV) pump operated drip irrigation system has been designed and developed for growing orchards in arid region considering different design parameters like pumps size, water requirements, the diurnal variation in the pressure of the pump due to change in irradiance and pressure compensation in the drippers. The system comprising a PV pump with 900 W{sub p} PV array and 800 W dc motor-pump mono-block, microfilter, main and sub-mains and three open-able low-pressure compensating drippers on each plant was field tested. The emission uniformity was observed to be 92-94% with discharge of 3.8 l/h in the pressure range of 70-100 kPa provided by the pump and thus the system could irrigate some 1 ha area within 2 h. Based on the performance of the PV pump and the drip system, it was inferred that about 5 ha area of orchard could be covered. The projected benefit-cost ratio for growing pomegranate orchards with such a system was evaluated to be above 2 even with the costly PV pump and therefore the system was considered to be an appropriate technology for the development of arid region. (Author)

  7. Galactic Archaeology with TESS: Prospects for Testing the Star Formation History in the Solar Neighbourhood

    Directory of Open Access Journals (Sweden)

    Thomas Alexandra

    2017-01-01

    proposed to explain the observed age-[α/Fe] distribution of stars in the solar neighbourhood. However, robust constraints on stellar ages are currently available for only a limited number of stars. The all-sky survey TESS (Transiting Exoplanet Survey Satellite will observe the brightest stars in the sky and thus can be used to investigate the age distributions of stars in these components of the Galaxy via asteroseismology, where previously this has been diffcult using other techniques. The aim of this preliminary study was to determine whether TESS will be able to provide evidence for quenching periods during the star formation history of the Milky Way. Using a population synthesis code, we produced populations based on various stellar formation history models and limited the analysis to red-giant-branch stars. We investigated the mass-Galactic-disk-height distributions, where stellar mass was used as an age proxy, to test for whether periods of quenching can be observed by TESS. We found that even with the addition of 15% noise to the inferred masses, it will be possible for TESS to find evidence for/against quenching periods suggested in the literature (e.g. between 7 and 9 Gyr ago, therefore providing stringent constraints on the formation and evolution of the Milky Way.

  8. Galactic Archaeology with TESS: Prospects for Testing the Star Formation History in the Solar Neighbourhood

    Science.gov (United States)

    Thomas, Alexandra; Stevenson, Emma; Gittins, Fabian W. R.; Miglio, Andrea; Davies, Guy; Girardi, Léo; Campante, Tiago L.; Schofield, Mathew

    2017-10-01

    A period of quenching between the formation of the thick and thin disks of the Milky Way has been recently proposed to explain the observed age-[α/Fe] distribution of stars in the solar neighbourhood. However, robust constraints on stellar ages are currently available for only a limited number of stars. The all-sky survey TESS (Transiting Exoplanet Survey Satellite) will observe the brightest stars in the sky and thus can be used to investigate the age distributions of stars in these components of the Galaxy via asteroseismology, where previously this has been diffcult using other techniques. The aim of this preliminary study was to determine whether TESS will be able to provide evidence for quenching periods during the star formation history of the Milky Way. Using a population synthesis code, we produced populations based on various stellar formation history models and limited the analysis to red-giant-branch stars. We investigated the mass-Galactic-disk-height distributions, where stellar mass was used as an age proxy, to test for whether periods of quenching can be observed by TESS. We found that even with the addition of 15% noise to the inferred masses, it will be possible for TESS to find evidence for/against quenching periods suggested in the literature (e.g. between 7 and 9 Gyr ago), therefore providing stringent constraints on the formation and evolution of the Milky Way.

  9. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Magnusson Turner, Lena; Søholt, Susanne

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  10. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Turner, Lena Magnusson; Søholt, Susanne

    2013-01-01

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  11. Inorganic arsenic –spe hg–aas method for rice tested in-house and collaboratively

    DEFF Research Database (Denmark)

    Rasmussen, Rie Romme; Qian, Yiting; Sloth, Jens Jørgen

    2013-01-01

    and is one of the major contributors to the iAs exposure in many countries. The work presented here describes the development, validation and application of a simple and inexpensive method for inorganic arsenic (iAs) determination in rice samples. The separation of iAs from organoarsenic compounds (MA...... sample extracts (pH 6±1) followed by selective elution of arsenate from a strong anion exchange SPE cartridge enabled the selective iAs quantification by HG-AAS, measuring total arsenic (As) in the SPE eluate. The in-house validation gave mean recoveries of 101–106 % for spiked rice samples and in two...... and DMA) was done by off-line solidphase extraction (SPE) followed by hydride generation atomic absorption spectrometry (HG-AAS) detection. Water bath heating (90 °C, 60 min) of samples with dilute nitric acid and hydrogen peroxide solubilised and oxidized all iAs to arsenate (AsV). Loading of buffered...

  12. A road map to solar neutrino fluxe, neutrino oscillation parameters, and tests for new physics

    CERN Document Server

    Bahcall, J N; Bahcall, John N.; Peña-Garay, Carlos

    2003-01-01

    We analyze all available solar and related reactor neutrino experiments, as well as simulated future ^7Be, p-p, pep, and ^8B solar neutrino experiments. We treat all solar neutrino fluxes as free parameters subject to the condition that the total luminosity represented by the neutrinos equals the observed solar luminosity (the `luminosity constraint'). Existing experiments show that the p-p solar neutrino flux is 1.01 + - 0.02 (1 sigma) times the flux predicted by the BP00 standard solar model; the ^7Be neutrino flux is 0.97^{+0.28}_{-0.54} the predicted flux; and the ^8B flux is 1.01 + - 0.06 the predicted flux. The oscillation parameters are: Delta m^2 = 7.3^{+0.4}_{-0.6} 10^{-5} eV^2 and tan^2 theta_{12} = 0.42^{+0.08}_{-0.06}. We evaluate how accurate future experiments must be to determine more precisely neutrino oscillation parameters and solar neutrino fluxes, and to elucidate the transition from vacuum-dominated to matter-dominated oscillations. A future ^7Be nu-e scattering experiment accurate to + -...

  13. Development of software for estimating clear sky solar radiation in Indonesia

    Science.gov (United States)

    Ambarita, H.

    2017-01-01

    Research on solar energy applications in Indonesia has come under scrutiny in recent years. Solar radiation is harvested by solar collector or solar cell and convert the energy into useful energy such as heat and or electricity. In order to provide a better configuration of a solar collector or a solar cell, clear sky radiation should be estimated properly. In this study, an in-house software for estimating clear sky radiation is developed. The governing equations are solved simultaneously. The software is tested in Medan city by performing a solar radiation measurements. For clear sky radiation, the results of the software and measurements ones show a good agreement. However, for the cloudy sky condition it cannot predict the solar radiation. This software can be used to estimate the clear sky radiation in Indonesia.

  14. Neutrino oscillations in the Earth suggest a terrestrial test of solution to solar neutrino problem

    International Nuclear Information System (INIS)

    Dar, A.; Mann, A.; Technicon-Israel Inst. of Tech., Haifa. Space Research Inst.)

    1987-01-01

    The verification of the Mikheyev-Smirnov-Wolfenstein (MSW) solution of the solar neutrino problem is discussed. One verification experiment concerns the detection of sizeable oscillations of atmospheric neutrinos in the earth, which can be detected with the massive underground proton decay detectors. Diurnal and seasonal modulations of the solar neutrino flux can perhaps be detected by the radiochemical Cl and Ga detectors. Moreover, neutrino oscillations in the Earth may modify the values of the oscillation parameters which can solve the solar neutrino problem and help determine their values. (UK)

  15. Smart Houses

    Science.gov (United States)

    1987-01-01

    GWS takes plans for a new home and subjects them to intensive computerized analysis that does 10,000 calculations relative to expected heat loss and heat gain, then provides specifications designed specifically for each structure as to heating, cooling, ventilation and insulation. As construction progresses, GWS inspects the work of the electrical, plumbing and insulation contractors and installs its own Smart House Radiant Barrier. On completion of the home, GWS technicians use a machine that creates a vacuum in the house and enables computer calculation of the air exchanged, a measure of energy efficiency. Key factor is the radiant barrier, borrowed from the Apollo program. This is an adaptation of a highly effective aluminized heat shield as a radiation barrier holding in or keeping out heat, cold air and water vapor.

  16. Solar powered adsorption refrigerator with CPC collection system: Collector design and experimental test

    International Nuclear Information System (INIS)

    Gonzalez, Manuel I.; Rodriguez, Luis R.

    2007-01-01

    Solar adsorption cooling systems are usually based on the flat plate collector, whereas little attention has been paid to concentrating collectors. Compound parabolic concentrators (CPC) are a versatile class of solar collectors that can be adapted to a large variety of applications and geometries. This work presents a CPC collector whose tubular receiver contains the sorption bed and where only a portion of the receiver is exposed to sunlight. Geometric characteristics of the proposed CPC, such as the profile, the length and the height of the reflective sheet are given. A prototype of a solar adsorption chiller using this type of collector and the activated carbon-methanol working pair is described, and typical experimental results are reported. In particular, the measured solar COP ranges from 0.078 to 0.096

  17. PERFORMANCE EVALUATION OF SOLAR COLLECTORS USING A SOLAR SIMULATOR

    OpenAIRE

    M. Norhafana; Ahmad Faris Ismail; Z. A. A. Majid

    2015-01-01

    Solar water heating systems is one of the applications of solar energy. One of the components of a solar water heating system is a solar collector that consists of an absorber. The performance of the solar water heating system depends on the absorber in the solar collector. In countries with unsuitable weather conditions, the indoor testing of solar collectors with the use of a solar simulator is preferred. Thus, this study is conducted to use a multilayered absorber in the solar collector of...

  18. Photosynthesis in a test tube- dye sensitized solar cells as a teaching tool

    Energy Technology Data Exchange (ETDEWEB)

    Raturi, Atul; Fepuleai, Yoheni [Division of Physics, School of Engineering and Physics, The University of the South Pacific, Suva (Fiji)

    2010-05-15

    Dye sensitized solar cells employing natural plant dyes as phosensitizers can be effectively used to train students in the science and technology of solar cells. This is especially relevant to developing countries where facilities for silicon cell fabrication are non-existent. The cross-disciplinary nature of this device makes it very attractive for student projects. The present work describes such a project where anthocyanin dye from hibiscus flowers has been used as the electron harvester. (author)

  19. ON USING THE COLOR-MAGNITUDE DIAGRAM MORPHOLOGY OF M67 TO TEST SOLAR ABUNDANCES

    International Nuclear Information System (INIS)

    Magic, Z.; Serenelli, A.; Weiss, A.; Chaboyer, B.

    2010-01-01

    The open cluster M67 has solar metallicity and an age of about 4 Gyr. The turnoff (TO) mass is close to the minimum mass for which solar metallicity stars develop a convective core during main sequence evolution as a result of the development of hydrogen burning through the CNO cycle. The morphology of the color-magnitude diagram (CMD) of M67 around the TO shows a clear hook-like feature, a direct sign that stars close to the TO have convective cores. VandenBerg et al. investigated the possibility of using the morphology of the M67 TO to put constraints on the solar metallicity, particularly CNO elements, for which solar abundances have been revised downward by more than 30% over the last few years. Here, we extend their work, filling the gaps in their analysis. To this aim, we compute isochrones appropriate for M67 using new (low metallicity) and old (high metallicity) solar abundances and study whether the characteristic TO in the CMD of M67 can be reproduced or not. We also study the importance of other constitutive physics on determining the presence of such a hook, particularly element diffusion, overshooting and nuclear reaction rates. We find that using the new solar abundance determinations, with low CNO abundances, makes it more difficult to reproduce the characteristic CMD of M67. This result is in agreement with results by VandenBerg et al. However, changes in the constitutive physics of the models, particularly overshooting, can influence and alter this result to the extent that isochrones constructed with models using low CNO solar abundances can also reproduce the TO morphology in M67. We conclude that only if all factors affecting the TO morphology are completely under control (and this is not the case), M67 could be used to put constraints on solar abundances.

  20. Long-term field test of solar PV power generation using one-axis 3-position sun tracker

    KAUST Repository

    Huang, B.J.

    2011-09-01

    The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand-alone solar-powered LED lighting systems. The field test in the particular days shows that the 1A-3P tracking PV can generate 35.8% more electricity than the fixed PV in a partly-cloudy weather with daily-total solar irradiation HT=11.7MJ/m2day, or 35.6% in clear weather with HT=18.5MJ/m2day. This indicates that the present 1A-3P tracking PV can perform very close to a dual-axis continuous tracking PV (Kacira et al., 2004). The long-term outdoor test results have shown that the increase of daily power generation of 1A-3P tracking PV increases with increasing daily-total solar irradiation. The increase of monthly-total power generation for 1A-3P sun tracking PV is between 18.5-28.0%. The total power generation increase in the test period from March 1, 2010 to March 31, 2011, is 23.6% in Taipei (an area of low solar energy resource). The long-term performance of the present 1X-3P tracking PV is shown very close to the 1-axis continuous tracking PV in Taiwan (Chang, 2009). If the 1A-3P tracking PV is used in the area of high solar energy resource with yearly-average HT>17MJ/m2day, the increase of total long-term power generation with respect to fixed PV will be higher than 37.5%. This is very close to that of dual-axis continuous tracking PV. The 1A-3P tracker can be easily mounted on the wall of a building. The cost of the whole tracker is about the same as the regular mounting cost of a conventional rooftop PV system. This means that there is no extra cost for 1A-3P PV mounted on buildings. The 1A-3P PV is quite suitable for building-integrated applications. © 2011 Elsevier Ltd.

  1. A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

    Science.gov (United States)

    Jaffe, Leonard D.

    1988-01-01

    This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

  2. A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

    Science.gov (United States)

    Jaffe, Leonard D.

    1988-11-01

    This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

  3. Solar Simulator

    Science.gov (United States)

    1981-01-01

    Oriel Corporation's simulators have a high pressure xenon lamp whose reflected light is processed by an optical system to produce a uniform solar beam. Because of many different types of applications, the simulators must be adjustable to replicate many different areas of the solar radiation spectrum. Simulators are laboratory tools for such purposes as testing and calibrating solar cells, or other solar energy systems, testing dyes, paints and pigments, pharmaceuticals and cosmetic preparations, plant and animal studies, food and agriculture studies and oceanographic research.

  4. Problematic of the integration of the solar panels in the cover of the buildings of houses; Problematica de la integracion de los paneles solares en la cubierta de los edificios de viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, F.

    2008-07-01

    This report describes schematically the different possibilities to place the thermal solar panels in a block of flats (building) between party walls and the precautions for their maintenance, pointing out the need to solve the formal aspects related to the resolution of the technical-functional aspects of the whole installation. This requires an interdisciplinary work in which the different sectors implied (architects, engineers, industry and communication) will have to intervene, in a word to take part. (Author)

  5. Solar energy guide

    International Nuclear Information System (INIS)

    Lentz, A.; Winter, R.

    1993-07-01

    Many aspects with regard to the practical use of solar energy are discussed. This guide is aimed at informing local and regional administrators, committee members of housing corporations and public utilities and public relations officers on the possibilities to use solar energy. In chapter one an overview is given of the use of solar energy in the housing sector, the recreational sector, agricultural sector, industry, trade and other sectors. In the chapters two, three and four attention is paid to passive solar energy, active thermal solar energy and photovoltaic energy respectively. In the chapters five and six aspects concerning the implementation of solar energy systems in practice are discussed. First an outline of the parties involved in implementing solar energy is given: the municipality, the energy utility, the province, local authorities, advisors, housing constructors and the occupants of the buildings. Then attention is paid to the consequences of implementing solar energy for the building inspection and regulations, the finances, energy savings and the environment. In chapter seven an overview is given of the subsidy regulations of the European Community, the Dutch national and local governments. Chapter contains addresses of solar thermal systems, photovoltaic systems and other institutes operating in the field of solar energy, as well as the titles of a number of brochures and courses. 51 figs., 7 tabs., 86 refs

  6. Is there a doctor in the house? : The presence of physicians in the direct-to-consumer genetic testing context.

    Science.gov (United States)

    Howard, Heidi Carmen; Borry, Pascal

    2012-04-01

    Over the last couple of years, many commercial companies, the majority of which are based in the USA, have been advertising and offering direct-to-consumer (DTC) genetic testing services outside of the established health care system, and often without any involvement from a health care professional. In the last year, however, a number of DTC genetic testing companies have changed their provision model such that consumers must now contact a health care professional before being able to order the genetic testing service. In discussing the advent of this new model of service provision, this article also reviews the ethical and social issues surrounding DTC genetic testing and addresses the potential motivations for change, some barriers to achieving truly appropriate medical supervision and the present reality of DTC genetic testing for some psychiatric and neurological disorders. Since the advent of these commercial activities, critics have pointed a finger at the lack of medical supervision surrounding these services. The discussion herein, however, reveals how difficult it may be, despite the addition of a physician, to actually achieve adequate medical supervision within the present context of DTC genetic testing.

  7. The dish on the Solar Decathlon

    Energy Technology Data Exchange (ETDEWEB)

    Meehan, Chris

    2011-07-01

    Within only one week, 19 collegiate teams had to build their technically-advanced, solar-powered, energy-efficient houses to wow judges and the public at this year's US Department of Energy's (DOE's) Solar Decathlon. The unassembled homes began arriving at the West Potomac Park of the National Mall in Washington, DC, at 11 p.m. on September 13. From then on it was a marathon to finish construction and compete in gauntlet of 10 events to test the designs. (orig.)

  8. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  9. Theoretical comparison between solar combisystems based on bikini tanks and tank-in-tank solar combisystems

    DEFF Research Database (Denmark)

    Yazdanshenas, Eshagh; Furbo, Simon; Bales, Chris

    2008-01-01

    Theoretical investigations have shown that solar combisystems based on bikini tanks for low energy houses perform better than solar domestic hot water systems based on mantle tanks. Tank-in-tank solar combisystems are also attractive from a thermal performance point of view. In this paper......, theoretical comparisons between solar combisystems based on bikini tanks and tank-in-tank solar combisystems are presented....

  10. Solar energy in practice

    International Nuclear Information System (INIS)

    Eijpe, H.A.

    1996-01-01

    One of the Dutch energy distribution companies (REMU) applies integrated passive, thermal and photovoltaic solar energy systems in fifty newly built dwellings in Amersfoort, Netherlands. The houses are equipped with a combi-boiler (solar energy and natural gas) and 22.5m 2 photovoltaic panels to produce electricity. Six houses are equipped with an electric heat pump, while the other 44 houses have a high-efficiency low-NO x combi-boiler. The experiences with the project so-far are outlined. 6 figs., 1 tab., 10 refs

  11. Reports on 1979 result of Sunshine Project. R and D on solar cooling/heating and hot-water supply system (R and D on system for newly built private housing); 1979 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-03-01

    This report is for the results of fiscal 1979 on a solar cooling/heating and hot-water supply system for newly-built private housing. The research reports for fiscal 1974 to 1978 are as reported so far; for example, the research on energy-saving construction including thermal insulation method was used in an experimental housing completed in fiscal 1976. The solar heat collecting device was built in the experimental housing by increasing the scale of and utilizing the heat collecting device of a vacuum glass tube type on which research was done before fiscal 1975. The absorption refrigerating machine incorporated in the housing was of a forced circulation type which was high in temperature stability using the result of the research carried out until then. In fiscal 1979, as in fiscal 1978, one year residential experiment was conducted in which a family of a couple and two children lived in a house under an improved system as a result of a system variation and the like, and made an evaluation on the performance. Simultaneously, a control management system was developed in which a micro-computer was introduced for the purpose of improving the system performance, with the operation carried out under the micro-computer control. In addition, a fundamental experiment was also completed concerning a long-term heat accumulation by underground heat reserve. (NEDO)

  12. Endothermic technology for domestic houses

    International Nuclear Information System (INIS)

    Virk, G.S.

    2005-01-01

    The paper introduces the endothermic energy systems being developed for buildings. These use the concept of solar assisted heat pumps where thermal energy is harvested using large integrated solar collectors connected to energy stores. The low grade energy is upgraded using heat pumps to provide thermal energy effectively to a wide variety of applications for space heating and cooling and hot water. The domestic housing sector is focused upon here and a current EC funded project aimed at assessing the potential of the endothermic technology for providing the thermal energy for space heating and cooling and hot water is presented. (author)

  13. The solar energy in Israel

    International Nuclear Information System (INIS)

    Bocquet, L.

    2004-05-01

    The solar energy is an important characteristic of Israel, listed in its history and its development. This document presents the solar energy applications in the country in many domains: the solar energy for residential houses, the applications in the agricultural and industrial sectors and the research and development programs. (A.L.B.)

  14. Sydney Opera House Rise

    DEFF Research Database (Denmark)

    2013-01-01

    Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House".......Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House"....

  15. Collecting Solar Energy. Solar Energy Education Project.

    Science.gov (United States)

    O'Brien, Alexander

    This solar energy learning module for use with junior high school students offers a list of activities, a pre-post test, job titles, basic solar energy vocabulary, and diagrams of solar energy collectors and installations. The purpose is to familiarize students with applications of solar energy and titles of jobs where this knowledge could be…

  16. Appropriate technology for solar energy system aiming water heating for human bath in houses of rural areas; Tecnologia apropriada para sistema de energia solar visando aquecimento de agua para o banho humano em moradias do meio rural

    Energy Technology Data Exchange (ETDEWEB)

    Rispoli, Italo Alberto Gatica [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo], e-mail: gatica@dglnet.com.br; Mariotoni, Carlos Alberto [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Civil, Arquitetura e Urbanismo. Nucleo Interdisciplinar de Planejamento Energetico], e-mail: cam@fec.unicamp.br

    2004-07-01

    The Brazilian land receives a great amount of solar radiation all over the year, therefore, because both the culture and practical aspects, Brazilians use in a non-moderate way the electricity to boil the water for human bath in the rural homes, in the lower income residences even at part of the medium class homes. That happens due to the very low price of an electrical shower, about US$ 6,5. In fact, that way of heating water is largely used because, besides the very low electrical shower price, it is not necessary to install a complete hot water both hydraulic and electrical building systems, but just both single hydraulic pipes and electrical devices. On the other hands, at rural regions where the electricity does not achieve the rural people uses firewood in order to get hot water for human bath. At the rural places the use of electrical showers has meaning an increase in the electrical transformers powers, heavier electrical transmission rural lines, with greater prices and, at the urban zones, the use of electrical showers in the lower social classes has contributed to a more expressive electrical load at the nacional electrical system load peck, between 5:30 to 8:30 a.m. The public administration, mostly, does not take into account both social, economic and environmental costs in order to think about the electricity offer. The solar heating systems, generally used in Brazil, conserves the same reservoirs used in France at 1880. Therefore, this paper presents some technical subsidies applied to rural homes, even to lower income people's homes aiming to stimulate the Brazilian public authorities to make a public police to facilitate both the industrialization and dissemination of solar heating systems, appropriate to the rural area, with lower costs, compounded by good technology equipment, with guarantee of lasting and quality. (author)

  17. Thermally Induced Vibrations of the Hubble Space Telescope's Solar Array 3 in a Test Simulated Space Environment

    Science.gov (United States)

    Early, Derrick A.; Haile, William B.; Turczyn, Mark T.; Griffin, Thomas J. (Technical Monitor)

    2001-01-01

    NASA Goddard Space Flight Center and the European Space Agency (ESA) conducted a disturbance verification test on a flight Solar Array 3 (SA3) for the Hubble Space Telescope using the ESA Large Space Simulator (LSS) in Noordwijk, the Netherlands. The LSS cyclically illuminated the SA3 to simulate orbital temperature changes in a vacuum environment. Data acquisition systems measured signals from force transducers and accelerometers resulting from thermally induced vibrations of the SAI The LSS with its seismic mass boundary provided an excellent background environment for this test. This paper discusses the analysis performed on the measured transient SA3 responses and provides a summary of the results.

  18. Testing of indoor radon reduction techniques in central Ohio houses: Phase 2 (Winter 1988-1989). Final report, September 1988-May 1989

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1990-05-01

    The report gives results of tests of developmental indoor radon reduction techniques in nine slab-on-grade and four crawl-space houses near Dayton, Ohio. The slab-on-grade tests indicated that, when there is a good layer of aggregate under the slab, the sub-slab ventilation (SSV) mitigation technique, with only one or two suction pipes, can generally reduce indoor concentrations below 2 pCi/L (86 to 99% reduction). These reductions can be achieved even when: there are forced-air supply ducts under the slab; the slab is large (up to 2600 sq ft); and the foundation walls are hollow block. Operating the SSV system in suction always gave greater reductions than did operating in pressure. The crawl-space tests demonstrated that depressurizing under a plastic liner over the crawl-space floor was able to reduce living-area radon concentrations below 2 pCi/L (81 to 96% reduction). The performance of such sub-liner depressurization gave better reductions than did crawl-space ventilation (blowing air into, or out of, the crawl space). Completely covering the crawl-space floor with plastic sheeting was not always necessary to get adequate performance

  19. Testing a solar coronal magnetic field extrapolation code with the Titov–Démoulin magnetic flux rope model

    International Nuclear Information System (INIS)

    Jiang, Chao-Wei; Feng, Xue-Shang

    2016-01-01

    In the solar corona, the magnetic flux rope is believed to be a fundamental structure that accounts for magnetic free energy storage and solar eruptions. Up to the present, the extrapolation of the magnetic field from boundary data has been the primary way to obtain fully three-dimensional magnetic information about the corona. As a result, the ability to reliably recover the coronal magnetic flux rope is important for coronal field extrapolation. In this paper, our coronal field extrapolation code is examined with an analytical magnetic flux rope model proposed by Titov and Démoulin, which consists of a bipolar magnetic configuration holding a semi-circular line-tied flux rope in force-free equilibrium. By only using the vector field at the bottom boundary as input, we test our code with the model in a representative range of parameter space and find that the model field can be reconstructed with high accuracy. In particular, the magnetic topological interfaces formed between the flux rope and the surrounding arcade, i.e., the “hyperbolic flux tube” and “bald patch separatrix surface,” are also reliably reproduced. By this test, we demonstrate that our CESE–MHD–NLFFF code can be applied to recovering the magnetic flux rope in the solar corona as long as the vector magnetogram satisfies the force-free constraints. (paper)

  20. Solar renovation demonstration projects

    Energy Technology Data Exchange (ETDEWEB)

    Bruun Joergensen, O [ed.

    1998-10-01

    In the framework of the IEA SHC Programme, a Task on building renovation was initiated, `Task 20, Solar Energy in Building Renovation`. In a part of the task, Subtask C `Design of Solar Renovation Projects`, different solar renovation demonstration projects were developed. The objective of Subtask C was to demonstrate the application of advanced solar renovation concepts on real buildings. This report documents 16 different solar renovation demonstration projects including the design processes of the projects. The projects include the renovation of houses, schools, laboratories, and factories. Several solar techniques were used: building integrated solar collectors, glazed balconies, ventilated solar walls, transparent insulation, second skin facades, daylight elements and photovoltaic systems. These techniques are used in several simple as well as more complex system designs. (au)

  1. Optimal control and performance test of solar-assisted cooling system

    KAUST Repository

    Huang, B.J.; Yen, C.W.; Wu, J.H.; Liu, J.H.; Hsu, H.Y.; Petrenko, V.O.; Chang, J.M.; Lu, C.W.

    2010-01-01

    temperature. This will make the SACH always produce cooling effect even at lower solar radiation periods while the ejector performs at off-design conditions. The energy saving of A/C is experimentally shown 50-70% due to the cooling performance of ECS

  2. Solar system tests of scalar field models with an exponential potential

    International Nuclear Information System (INIS)

    Paramos, J.; Bertolami, O.

    2008-01-01

    We consider a scenario where the dynamics of a scalar field is ruled by an exponential potential, such as those arising from some quintessence-type models, and aim at obtaining phenomenological manifestations of this entity within our Solar System. To do so, we assume a perturbative regime, derive the perturbed Schwarzschild metric, and extract the relevant post-Newtonian parameters.

  3. Energy dependence of solar-neutrino--electron scattering as a test of neutral currents

    International Nuclear Information System (INIS)

    Kwong, W.; Rosen, S.P.

    1992-01-01

    The energy dependence of ν-e scattering of solar neutrinos is investigated in the framework of neutrino oscillations and the nonadiabatic Mikheyev-Smirnov-Wolfenstein effect. It is shown that, with sufficient data, it will be possible to establish unambiguously whether neutrino oscillations are actually occurring and whether the electron neutrino oscillates into active or inactive (sterile) neutrino flavors

  4. A Solar Powered Wireless Computer Mouse: Design, Assembly and Preliminary Testing of 15 Prototypes

    NARCIS (Netherlands)

    van Sark, W.G.J.H.M.; Reich, N.H.; Alsema, E.A.; Netten, M.P.; Veefkind, M.; Silvester, S.; Elzen, B.; Verwaal, M.

    2007-01-01

    The concept and design of a solar powered wireless computer mouse has been completed, and 15 prototypes have been successfully assembled. After necessary cutting, the crystalline silicon cells show satisfactory efficiency: up to 14% when implemented into the mouse device. The implemented voltage

  5. Housing markets and housing policies in India

    OpenAIRE

    Tiwari, Piyush; Rao, Jyoti

    2016-01-01

    Issues of housing in India are synonymous with ignorance of housing in active government involvement at the policy and program formulation levels. They are also due to the problems that unplanned urbanization, income disparity, poverty, illiteracy, and unemployment brought. These issues extenuated the housing problem, causing a housing shortage of 51 million in 2011. Though India has a long history of establishing policies, programs, and institutions to cater to housing, without allocating ad...

  6. Development of a Measure of Housing and Housing Services.

    Science.gov (United States)

    Clark, Colleen; Young, M Scott; Teague, Gregory; Rynearson-Moody, Sarah

    2016-01-01

    The Housing Program Measure (HPM) was designed to document critical elements of a range of housing program types and associated services. Qualitative methods, including literature review and open-ended interviews, were used to determine pertinent HPM domains and to develop the pool of items. The measure was pre-tested, and reliability and validity analyses were applied to revise and strengthen the measure. The resulting measure furthers homelessness research by providing a tool that can be used to define housing and housing services interventions across diverse projects and disciplines, to facilitate program management by matching housing resources to the needs of homeless individuals, and to support model development by measuring progress to goals.

  7. Solar Sprint

    Science.gov (United States)

    Tabor, Richard; Anderson, Stephen

    2007-01-01

    In the "Solar Sprint" activity, students design, test, and race a solar-powered car built with Legos. The use of ratios is incorporated to simulate the actual work of scientists and engineers. This method encourages fourth-grade students to think about multiple variables and stimulates their curiosity when an activity doesn't come out as…

  8. Solar constraints

    International Nuclear Information System (INIS)

    Provost, J.

    1984-01-01

    Accurate tests of the theory of stellar structure and evolution are available from the Sun's observations. The solar constraints are reviewed, with a special attention to the recent progress in observing global solar oscillations. Each constraint is sensitive to a given region of the Sun. The present solar models (standard, low Z, mixed) are discussed with respect to neutrino flux, low and high degree five-minute oscillations and low degree internal gravity modes. It appears that actually there do not exist solar models able to fully account for all the observed quantities. (Auth.)

  9. House dust extracts contain potent immunological adjuvants

    NARCIS (Netherlands)

    Beukelman, C.J.; Dijk, H. van; Aerts, P.C.; Rademaker, P.M.; Berrens, L.; Willers, J.M.N.

    1987-01-01

    A crude aqueous extract of house dust and two house dust subfractions were tested for adjuvant activity in a sensitivity assay performed in mice. Evidence is presented that house dust contains at least two potent immunological adjuvants. One of these, present in both subfractions, was probably

  10. Recommendations and tools to design houses with passive solar cooling and mating in Mediterranean Sea; Recomendaciones y herramientas para el diseno de viviendas con calefaccion solar y climatizacion pasiva en una zona de clima mediterraneo

    Energy Technology Data Exchange (ETDEWEB)

    Muller, E.

    2004-07-01

    Recommendations for passive design and design tools based on European building codes were developed with extensive thermal simulations and a reference year especially prepared with hourly climate data from the central region of Chile. The results of the research were presented as a manual in Spanish enclosing simple design tools in an electronic spreadsheet. The design analysis is presented with a novel approach, that permits a better understanding and optimisation of the complex design balance between the demands for summer and winter in a mediterranean climate. The methodologies and approach that were developed are extended to other climatic regions. This way the investigation supports the improvement of thermal comfort conditions and the application of solar energy in dwellings as essential elements of a process of sustainable development. (Author)

  11. Recent advances in solar photovoltaic technology

    International Nuclear Information System (INIS)

    Yoshihiro Hamakawa

    2000-01-01

    The current state of the art in recent progress of Japanese photovoltaic activities are overviewed. Firstly, a new strategy for the renewable energy promotion so called Fundamental Principle to promote New Energy Developments and Utilization, and its action planning for PV technology up to year of 2010 are introduced. The program structure and some tangible actions such as tax reduction for investment in the renewable energy plants, government financial support of 2/3 subsidy of PV system developments for public facilities namely as PV Field Test Experiments, and a 1/2 subsidy for the private solar house as PV House Monitor Plan are presented. Secondly, some new topics in the field of solar cell production technology in Japan and also statistics of the solar cell module productions for three kinds of silicon basis solar cells are summarized. Progress of the conversion efficiency in various types of solar cells are also surveyed. In the final part of paper possible new roles to contribute to the global environmental issues by the PV system developments are proposed. (Author)

  12. Testing the very-short-baseline neutrino anomalies at the solar sector

    Science.gov (United States)

    Palazzo, Antonio

    2011-06-01

    Motivated by the accumulating hints of new sterile neutrino species at the eV scale, we explore the consequences of such an hypothesis on the solar sector phenomenology. After introducing the theoretical formalism needed to describe the Mikheyev-Smirnov-Wolfenstein conversion of solar neutrinos in the presence of one (or more) sterile neutrino state(s) located “far” from the (ν1, ν2) “doublet”, we perform a quantitative analysis of the available experimental results, focusing on the electron neutrino mixing. We find that the present data posses a sensitivity to the amplitude of the lepton mixing matrix element Ue4—encoding the admixture of the electron neutrino with a new mass eigenstate—which is comparable to that achieved on the standard matrix element Ue3. In addition, and more importantly, our analysis evidences that, in a 4-flavor framework, the current preference for |Ue3|≠0 is indistinguishable from that for |Ue4|≠0, having both a similar statistical significance (which is ˜1.3σ adopting the old reactor fluxes determinations, and ˜1.8σ using their new estimates.) We also point out that, differently from the standard 3-flavor case, in a 3+1 scheme the Dirac CP-violating phases cannot be eliminated from the description of solar neutrino conversions.

  13. SOLAR WAVE-FIELD SIMULATION FOR TESTING PROSPECTS OF HELIOSEISMIC MEASUREMENTS OF DEEP MERIDIONAL FLOWS

    International Nuclear Information System (INIS)

    Hartlep, T.; Zhao, J.; Kosovichev, A. G.; Mansour, N. N.

    2013-01-01

    The meridional flow in the Sun is an axisymmetric flow that is generally directed poleward at the surface, and is presumed to be of fundamental importance in the generation and transport of magnetic fields. Its true shape and strength, however, are debated. We present a numerical simulation of helioseismic wave propagation in the whole solar interior in the presence of a prescribed, stationary, single-cell, deep meridional circulation serving as synthetic data for helioseismic measurement techniques. A deep-focusing time-distance helioseismology technique is applied to the synthetic data, showing that it can in fact be used to measure the effects of the meridional flow very deep in the solar convection zone. It is shown that the ray approximation that is commonly used for interpretation of helioseismology measurements remains a reasonable approximation even for very long distances between 12° and 42° corresponding to depths between 52 and 195 Mm. From the measurement noise, we extrapolate that time-resolved observations on the order of a full solar cycle may be needed to probe the flow all the way to the base of the convection zone.

  14. Solar/electric heating systems for the future energy system

    Energy Technology Data Exchange (ETDEWEB)

    Furbo, S.; Dannemand, M.; Perers, B. [and others

    2013-05-15

    The aim of the project is to elucidate how individual heating units for single family houses are best designed in order to fit into the future energy system. The units are based on solar energy, electrical heating elements/heat pump, advanced heat storage tanks and advanced control systems. Heat is produced by solar collectors in sunny periods and by electrical heating elements/heat pump. The electrical heating elements/heat pump will be in operation in periods where the heat demand cannot be covered by solar energy. The aim is to use the auxiliary heating units when the electricity price is low, e.g. due to large electricity production by wind turbines. The unit is equipped with an advanced control system where the control of the auxiliary heating is based on forecasts of the electricity price, the heat demand and the solar energy production. Consequently, the control is based on weather forecasts. Three differently designed heating units are tested in a laboratory test facility. The systems are compared on the basis of: 1) energy consumption for the auxiliary heating; 2) energy cost for the auxiliary heating; 3) net utilized solar energy. Starting from a normal house a solar combi system (for hot water and house heating) can save 20-30% energy cost, alone, depending on sizing of collector area and storage volume. By replacing the heat storage with a smart tank based on electric heating elements and a smart control based on weather/load forecast and electricity price information 24 hours ahead, another 30-40% can be saved. That is: A solar heating system with a solar collector area of about 10 m{sup 2}, a smart tank based on electric heating element and a smart control system, can reduce the energy costs of the house by at least 50%. No increase of heat storage volume is needed to utilize the smart control. The savings in % are similar for different levels of building insulation. As expected a heat pump in the system can further reduce the auxiliary electricity

  15. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  16. Building America Industrialized Housing Partnership (BAIHP)

    Energy Technology Data Exchange (ETDEWEB)

    McIlvaine, Janet; Chandra, Subrato; Barkaszi, Stephen; Beal, David; Chasar, David; Colon, Carlos; Fonorow, Ken; Gordon, Andrew; Hoak, David; Hutchinson, Stephanie; Lubliner, Mike; Martin, Eric; McCluney, Ross; McGinley, Mark; McSorley, Mike; Moyer, Neil; Mullens, Mike; Parker, Danny; Sherwin, John; Vieira, Rob; Wichers, Susan

    2006-06-30

    This final report summarizes the work conducted by the Building America Industrialized Housing Partnership (www.baihp.org) for the period 9/1/99-6/30/06. BAIHP is led by the Florida Solar Energy Center of the University of Central Florida and focuses on factory built housing. In partnership with over 50 factory and site builders, work was performed in two main areas--research and technical assistance. In the research area--through site visits in over 75 problem homes, we discovered the prime causes of moisture problems in some manufactured homes and our industry partners adopted our solutions to nearly eliminate this vexing problem. Through testing conducted in over two dozen housing factories of six factory builders we documented the value of leak free duct design and construction which was embraced by our industry partners and implemented in all the thousands of homes they built. Through laboratory test facilities and measurements in real homes we documented the merits of 'cool roof' technologies and developed an innovative night sky radiative cooling concept currently being tested. We patented an energy efficient condenser fan design, documented energy efficient home retrofit strategies after hurricane damage, developed improved specifications for federal procurement for future temporary housing, compared the Building America benchmark to HERS Index and IECC 2006, developed a toolkit for improving the accuracy and speed of benchmark calculations, monitored the field performance of over a dozen prototype homes and initiated research on the effectiveness of occupancy feedback in reducing household energy use. In the technical assistance area we provided systems engineering analysis, conducted training, testing and commissioning that have resulted in over 128,000 factory built and over 5,000 site built homes which are saving their owners over $17,000,000 annually in energy bills. These include homes built by Palm Harbor Homes, Fleetwood, Southern Energy

  17. Solar power from the supermarket. Water heating, space heating and air conditioning with solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    1976-08-01

    The different ways of utilizing solar energy are discussed. So far, top water heating is still the most practicable and most economical solution. Model houses with solar collectors, built by BBC and Philips, are dealt with in particular.

  18. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for new detached houses); 1994 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu. Shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-30

    This report describes the fiscal 1974 result on the solar cooling/heating and hot water supply system. The report includes the system analysis result (collection of existing technical data, analysis of weather conditions, profitability assessment, concept design of the primary experimental house), and the research result on equipment and materials (view and evaluation of existing technologies, selective transparent and absorption materials, the primary prototype solar heat collector model, refrigerator). As the study result, the spheroidal experimental house was adopted. The solar heat utilization system is a central air-conditioning equipment composed of heating by hot water obtained from the solar heat collector, and cooling by absorption refrigerator. Heat collection efficiencies were measured for (1) stainless steel substrate collector, (2) copper substrate collector, and (3) glass pipe collector prepared as prototype collectors. (2) was higher in heat collection efficiency than (1). The efficiency of (3) hardly increased by rise in heat collection temperature due to vacuum structure and selective absorption membrane. Further measurement of such characteristics is necessary at higher temperatures. (NEDO)

  19. Low-energy house in Sisimiut - Measurement equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hvidthoeft Delff Andersen, P.; Rode, C.; Madsen, Henrik

    2013-08-15

    This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. (Author)

  20. United States housing, 2012

    Science.gov (United States)

    Delton Alderman

    2013-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.