WorldWideScience

Sample records for sodar intercomparison experiment

  1. Results from a three-month intercomparison of boundary-layer wind profiler and sodar wind measurements at Lindenberg, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Beyrich, F.; Goersdorf, U.; Neisser, J.; Steinhagen, H.; Weisensee, U. [Deutscher Wetterdienst, Lindenberg (Germany). Meteorologisches Observatorium

    1998-10-01

    Intercomparison experiments with a wind profiler and a Doppler sodar have been performed at the meteorological observatory Lindenberg of the German weather service in summer, 1994, and in autumn, 1995, over a total period of about three months. The paper presents selected results of the wind measurements performed with the two systems. Sodar and wind profiler are shown to complement each other quite well. Therefore, a combination of both is a promising tool for continuous, high-resolution measurements of the wind profile. A problem to be solved is the construction of composite wind profiles when the measurements with the two systems disagree in the height range of overlapping. Measurements of the vertical velocity are difficult to assess due to their small absolute values. Long-term averages of the vertical velocity show slightly negative values, especially for the wind profiler. However, similar signatures have been found in the vertical velocity time series during frontal passages or during well-developed convection. (orig.) 7 refs.

  2. Wind measurements with SODAR during strong temperature inversions near the ground

    International Nuclear Information System (INIS)

    Thomas, P.; Vogt, S.

    1989-08-01

    SODAR (Sound Detection and Ranging) equipment has been increasingly used to measure vertical wind profiles with little expenditure in terms of staff, continuously over time and with a good spatial resolution. These informations serve as input variables for atmospheric transport and dispersion models, environmental monitoring of industrial facilities and, generally, for investigating a broad spectrum of meteorological phenomena. The SODAR principle has proved its suitability since long provided that the data recorded with SODAR have served to establish wind statistics valid for extended periods of time. At industrial sites potentially releasing substances prejudicial to health, e.g., chemical plants, nuclear power plants, etc., a SODAR must, moreover, be capable of measuring reliable the wind conditions also during short periods of release. This would, e.g., be important during accidental releases. Especially interesting situations for pollutant dispersion are distinct temperature inversions. It will be examined in this paper whether a SODAR is capable of measuring reliably the wind conditions also during those inversions. The selection of the situations of inversion as well as the direct intercomparison of data supplied by SODAR and conventional wind measuring instruments (anemometer and wind vane) are possible at the 200 m meteorological tower erected at the Karlsruhe Nuclear Research Center. The comparison between SODAR and the meteorological tower has shown that a SODAR is able to measure reliably the wind data also in situations characterized by strong ground-based and elevated inversions, respectively. (orig./KW) [de

  3. Atmospheric studies with SODAR at Kalpakkam

    International Nuclear Information System (INIS)

    Somayaji, K.M.

    1991-01-01

    A doppler SODAR for measurement of wind characteristics at different heights has been installed at HASL, IGCAR, Kalpakkam and is in operation since January 1990. The technical specifications and the basic aspects of SODAR, siting considerations and installation details are given. The report also discusses some observations regarding the site selection, installation and operation of SODARs. The basic theory of SODARs, some aspects of turbulence and dispersion in atmosphere and the various stability classification schemes are outlined. Some details regarding land/sea-breeze circulations and inversions are also given. (author). 6 refs., 10 figs., 8 annextures

  4. Validation of Sodar Measurements for Wind Power

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose

    2006-01-01

    the project and a new remote power system has been designed. A direct comparison between SODAR and cup measurements revealed a limitation for the SODAR measurements during different weather conditions, especially since the SODAR was not able to measure wind speeds above 15 m/s due to an increasing back-ground......A ground-based SODAR has been tested for 1½ years together with a traditional measurement set-up consisting of cups and vanes for measuring wind data for wind power assessment at a remote location. Many problems associated to the operation of a remote located SODAR have been solved during...... noise. Instead, using the SODAR as a profiler to establish representative wind speed profiles was successful. These wind speed profiles are combined with low height reference measurements to establish reliable hub height wind speed distributions. Representative wind speed profiles can be establish...

  5. On the operating experience of the Doppler Sodar system at the Forschungszentrum Juelich

    International Nuclear Information System (INIS)

    Adiga, B.B.; Zeuner, G.

    1990-04-01

    In this report the description and the operating principles of the Doppler Sodar at the KFA are briefly described and outputs from the routine operation of the Sodar are compared with the concurrently measured data on the 120 m high KFA meteorological tower. Three sets of data, varying from periods of ten days to 18 days, are used for the comparison. (orig.)

  6. Inter comparison of two commercially available SODARS

    DEFF Research Database (Denmark)

    Ejsing Jørgensen, Hans; Antoniou, I.

    2002-01-01

    In the present work two SODARs of the phased array type are compared indirectly using the top anemometer readings from the Risoe 125m instrumented meteorology mast. The two SODARs are the AeroVironment 4000 and the Metek DSDPA.90-24.......In the present work two SODARs of the phased array type are compared indirectly using the top anemometer readings from the Risoe 125m instrumented meteorology mast. The two SODARs are the AeroVironment 4000 and the Metek DSDPA.90-24....

  7. Validation of Sodar Measurements for Wind Power

    OpenAIRE

    Hansen, Kurt Schaldemose

    2006-01-01

    A ground-based SODAR has been tested for 1½ years together with a traditional measurement set-up consisting of cups and vanes for measuring wind data for wind power assessment at a remote location. Many problems associated to the operation of a remote located SODAR have been solved during the project and a new remote power system has been designed. A direct comparison between SODAR and cup measurements revealed a limitation for the SODAR measurements during different weather conditions, espec...

  8. Description of SODAR data storage. WISE project WP2

    International Nuclear Information System (INIS)

    Barhorst, S.A.M.; Verhoef, J.P.; Van der Werff, P.A.; Eecen, P.J.

    2003-10-01

    The partners in the WISE project are investigating whether application of the SODAR (sonic detection and ranging) measurement technique in wind energy experimental work is feasible as a replacement for cup anemometers and wind direction sensors mounted on tall meteorological masts both from the view of accuracy and cost. In Work Package 2 (WP2) of the WISE project extensive controlled experiments with the SODAR have been performed. For example, SODAR measurements have been compared with measurements from nearby masts and different brands of SODARs have been compared. Part of the work package was the creation of a database to gather the measured SODAR data. The database was created by ECN in order to enable further analysis by the partners in the project. The database structure that has been defined by ECN is described in full detail. The database is based on SQL (structured query language), and care is taken that data that is unchanged during a measurement period is only stored once. The logic behind the structure is described and the relations between the various tables are described. Up to now the description of the database is limited to include SODAR data measured close to a meteorological mast. Power measurements from wind turbines are not yet included. However, the database can easily be extended to include these data. The data measured by means of the ECN SODAR have completely been re-processed. A new directory structure was defined which is accessible from both the Unix (Linux) and the Microsoft Windows platform. The processed and validated data have been stored in a database to make retrieval of specific data sets possible. The database is also accessible from the Windows platform. The defined format is available for the WISE project, so that the database containing data from all partners can be created

  9. Third IAEA nuclear accident intercomparison experiment

    Energy Technology Data Exchange (ETDEWEB)

    Miric, I; Ubovic, Z

    1974-05-15

    The purpose of this report is to present the results of the International Atomic Energy Agency intercomparison experiments held at the 'Boris Kidric' Institute, Vinca, in May 1973. The experiments are parts of a multilaboratory intercomparison programme sponsored by the IAEA for the evaluation of nuclear accident dosimetry systems and eventually recommendation of dosimetry systems that will provide adequate informations in the event of a criticality accident. The previous two studies were held at the Valduc Centre near Dijon (France) in June 1970 and at the ORNL in Oak Ridge (USA), in May 1971. Parts of the intercomparison studies were coordination meetings. The topics and conclusions of the Third coordination meeting are given in the Chairman's Report of F.F. Haywood. This paper will deal, therefore, only with data concerning the Third intercomparison experiments in which the RB reactor at Vinca was used as a source of mixed radiation. (author)

  10. Third IAEA nuclear accident intercomparison experiment

    International Nuclear Information System (INIS)

    Miric, I.; Ubovic, Z.

    1974-05-01

    The purpose of this report is to present the results of the International Atomic Energy Agency intercomparison experiments held at the 'Boris Kidric' Institute, Vinca, in May 1973. The experiments are parts of a multilaboratory intercomparison programme sponsored by the IAEA for the evaluation of nuclear accident dosimetry systems and eventually recommendation of dosimetry systems that will provide adequate informations in the event of a criticality accident. The previous two studies were held at the Valduc Centre near Dijon (France) in June 1970 and at the ORNL in Oak Ridge (USA), in May 1971. Parts of the intercomparison studies were coordination meetings. The topics and conclusions of the Third coordination meeting are given in the Chairman's Report of F.F. Haywood. This paper will deal, therefore, only with data concerning the Third intercomparison experiments in which the RB reactor at Vinca was used as a source of mixed radiation. (author)

  11. The surface layer observed by a high-resolution sodar at DOME C, Antarctica

    Directory of Open Access Journals (Sweden)

    Stefania Argentini

    2014-01-01

    Full Text Available One year field experiment has started on December 2011 at the French - Italian station of Concordia at Dome C, East Antarctic Plateau. The objective of the experiment is the study of the surface layer turbulent processes under stable/very stable stratifications, and the mechanisms leading to the formation of the warming events. A sodar was improved to achieve the vertical/time resolution needed to study these processes. The system, named Surface Layer sodar (SL-sodar, may operate both in high vertical resolution (low range and low vertical resolution (high range modes. In situ turbulence and radiation measurements were also provided in the framework of this experiment. A few preliminary results, concerning the standard summer diurnal cycle, a summer warming event, and unusually high frequency boundary layer atmospheric gravity waves are presented.

  12. Noise and Vibrations Measurements. External noise and vibrations measurements for offshore SODAR application

    International Nuclear Information System (INIS)

    Ormel, F.T.; Eecen, P.J.; Herman, S.A.

    2003-10-01

    The partners in the WISE project investigate whether application of the SODAR (sonic detection and ranging) measurement technique in wind energy experimental work is feasible as a replacement for cup anemometers, wind direction sensors and tall meteorological masts. In Work Package 2 of the WISE project extensive controlled experiments with the SODAR are performed. For example SODAR measurements are compared with measurements from nearby masts and different brands of SODARs are compared. Part of the work package is the measurement of vibration and noise on an offshore SODAR system. The results of these measurements are presented in this report. ECN performed measurements at an offshore location to investigate the influence of noise and vibrations on the performance of a MiniSODAR measurement system. The aim of the measurements is to quantify the effect of these external noise and vibrations disturbances on the MiniSODAR's performance. Measurements on an identical SODAR system onshore are carried out to compare the disturbances of offshore and onshore external conditions. The effect of background noise on SODAR operation has clearly been established in literature. Therefore, measurements have been performed only to establish the absolute sound pressure levels. This is done at the Measuring Platform Noordwijk (MPN) located in the North Sea, nine kilometres out of the coast at Noordwijk, The Netherlands, and at two locations onshore. At the MPN-platform, the SODAR has been moved from the middle deck to the upper deck to diminish the influence of the diesel generator needed for the electric powering of the island. Although the absolute sound pressure level became higher at the new location, this level became lower at the most important frequencies inside the SODAR, due to the use of absorbing foam. With regards to the sound pressure level the move improved the situation. The sound pressure levels measured offshore were 6 to 15 dB higher than for the two locations

  13. Experimenting with sodar in support of emergency preparedness at Three Mile Island-1

    International Nuclear Information System (INIS)

    Heck, W.J.

    1989-01-01

    In November 1988 at Three Mile Island Unit 1 (TMI-1), GPU Nuclear successfully completed the annual drill-for-grade that, from a modeling point of view, broke new ground for this plant. The meteorological and modeling aspects of the drill scenario were unprecedented for two reasons. First, the plume was buoyant and rose far above the height of the meteorological tower located at TMI. Second, the wind direction data from the meteorological tower were not representative of the wind direction at plume height. In the drill scenario, the buoyant plume resulted from a steam generator tube rupture where the steam ejects directly into the atmosphere via safety relief valves. Plume modeling indicated that the plume would rise to 400 ft, given the scenario meteorology. Wind data from the on-site meteorological tower, however, was only available up to 150 ft. Comparisons of sodar and tower winds were made for various weather conditions. Sodar results were studied in detail during light, moderate, and high winds; various wind directions; occurrences of rain and snow; and by time of day to determine effects of diurnal meteorological conditions on sodar performance

  14. Robust, 'blind', in-situ calibration of SODARs

    International Nuclear Information System (INIS)

    Bradley, S

    2008-01-01

    Doppler spectra for SODARs are an average weighted over a volume according to the generally unknown beam pattern. By tilting the SODAR at a number of known angles, the beam pattern 'kernel' can be obtained and hence an absolute (field) calibration. No assumptions are required and the method does not require any comparison against mast or other installations

  15. Robust, 'blind', in-situ calibration of SODARs

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, S [Physics Department, The University of Auckland, Private Bag 92019, Auckland (New Zealand); School of Computing, Science and Engineering, University of Salford, M5 4WT (United Kingdom)], E-mail: s.bradley@auckland.ac.nz

    2008-05-01

    Doppler spectra for SODARs are an average weighted over a volume according to the generally unknown beam pattern. By tilting the SODAR at a number of known angles, the beam pattern 'kernel' can be obtained and hence an absolute (field) calibration. No assumptions are required and the method does not require any comparison against mast or other installations.

  16. Wind speed errors for LIDARs and SODARs in complex terrain

    International Nuclear Information System (INIS)

    Bradley, S

    2008-01-01

    All commercial LIDARs and SODARs are monostatic and hence sample distributed volumes to construct wind vector components. We use an analytic potential flow model to estimate errors arising for a range of LIDAR and SODAR configurations on hills and escarpments. Wind speed errors peak at a height relevant to wind turbines and can be typically 20%

  17. Wind speed errors for LIDARs and SODARs in complex terrain

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, S [Physics Department, The University of Auckland, Private Bag 92019, Auckland (New Zealand) and School of Computing, Science and Engineering, University of Salford, M5 4WT (United Kingdom)], E-mail: s.bradley@auckland.ac.nz

    2008-05-01

    All commercial LIDARs and SODARs are monostatic and hence sample distributed volumes to construct wind vector components. We use an analytic potential flow model to estimate errors arising for a range of LIDAR and SODAR configurations on hills and escarpments. Wind speed errors peak at a height relevant to wind turbines and can be typically 20%.

  18. Optimization of the SODAR preprocessor MPS

    International Nuclear Information System (INIS)

    Thielen, H.; Martens, R.; Massmeyer, K.

    1999-01-01

    The data measured by meteorological monitoring stations at the site of nuclear installations form the basis for calculation and fast assessment of the atmospheric dispersion of radionuclides released in an accident, and the resulting population exposure. Application of modern atmospheric dispersion models, as eg. that of the French-German Commission (DFK model), requires a novel calculation method for determination of boundary layer parameters based on SODAR information and supplementary meteorological measurements. For the research project St. Sch. 4102, the meteorological preprocessor for SODAR data (MPS) has been developed and is explained in the reports /THI 96/ and THI 98/. The task of the research project St.Sch. 4166 reported here was to optimize the MPS and carry out relevant validations. (orig./CB) [de

  19. Nuclear accident dosimetry, Report on the Third IAEA intercomparison experiment at Vinca, Yugoslavia

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-15

    The objective of this report is to present the results of the third IAEA intercomparison experiment held at the Boris Kidric Institute, Vinca, in May 1973. These experiments were a part of multi laboratory intercomparison programme sponsored by the IAEA for evaluation of nuclear accident dosimetry systems that ought to provide adequate information in the event of criticality accidents. This report deals with the data concerning the Third intercomparison experiments in which the RB reactor at Vinca was used as a source of mixed radiation.

  20. A scanning bi-static SODAR

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, P; Bradley, S [Physics Department, Auckland University, 38 Princes Street, Auckland (New Zealand); Hunerbein, S von [Acoustics Department, Newton Building, University of Salford, Greater Manchester M5 4WT (United Kingdom)

    2008-05-01

    Field results are given from a bi-static SODAR which uses a single central vertical transmission and three distributed microphone array receivers. Fourier transform delay methods are applied to data sampled from each microphone to retrospectively scan in angle and follow the transmitted pulse. Advantages of sampling a narrow atmospheric column, rather than distributed volumes are discussed.

  1. A scanning bi-static SODAR

    International Nuclear Information System (INIS)

    Behrens, P; Bradley, S; Hunerbein, S von

    2008-01-01

    Field results are given from a bi-static SODAR which uses a single central vertical transmission and three distributed microphone array receivers. Fourier transform delay methods are applied to data sampled from each microphone to retrospectively scan in angle and follow the transmitted pulse. Advantages of sampling a narrow atmospheric column, rather than distributed volumes are discussed

  2. Boundary layer height estimation by sodar and sonic anemometer measurements

    International Nuclear Information System (INIS)

    Contini, D; Cava, D; Martano, P; Donateo, A; Grasso, F M

    2008-01-01

    In this paper an analysis of different methods for the calculation of the boundary layer height (BLH) using sodar and ultrasonic anemometer measurements is presented. All the methods used are based on single point surface measurements. In particular the automatic spectral routine developed for Remtech sodar is compared with the results obtained with the parameterization of the vertical velocity variance, with the calculation of a prognostic model and with a parameterization based on horizontal velocity spectra. Results indicate that in unstable conditions the different methods provide similar pattern, with BLH relatively low, even if the parameterization of the vertical velocity variance is affected by a large scatter that limits its efficiency in evaluating the BLH. In stable nocturnal conditions the performances of the Remtech routine are lower with respect to the ones in unstable conditions. The spectral method, applied to sodar or sonic anemometer data, seems to be the most promising in order to develop an efficient routine for BLH determination

  3. Study on application of Doppler SODAR as meteorological observation tool at nuclear power plant

    International Nuclear Information System (INIS)

    Katayose, Naoto; Akai, Yukio.

    1993-01-01

    Among the remote sensing devices usable for meteorological observation, which became possible with the advent of modern science and technology, Doppler SODAR was selected for further study aimed at its practical application for nuclear power plants. This device was installed for testing purpose at a Japanese nuclear power and data collection (wind speed and direction) was carried out throughout one year there. The data on the selected SODAR have shown a correlation with those collected by the conventional method which is good enough to justify the SODAR's practical use at nuclear power plants. (author)

  4. Use of a tethersonde measurement system to conduct a Doppler SODAR performance audit

    Energy Technology Data Exchange (ETDEWEB)

    Wilkerson, G.W. [North American Weather Consultants, Salt Lake City, UT (United States); Catizone, P.A. [TRC Environmental Corp., Windsor, CT (United States); Coble, T.D. [ASARCO Inc., East Helena, MT (United States)

    1994-12-31

    With the increased usage of dispersion models that require stack top wind information, such as the Complex Terrain Dispersion Model (CTDM), the need for a reliable method to collect elevated wind data has also increased. Doppler Sound Detection and Ranging (SODAR) instruments have gained recognition as a viable means of collecting such data. SODAR technology has improved greatly over the last decade and is now a cost effective alternative to tall meteorological towers. SODARs are remote sensing devices that sample the atmosphere and calculate wind speed and wind direction data at different altitudes. This is accomplished by measuring the doppler shift of an acoustic pulse emitted by a ground level antenna.

  5. On the theory of SODAR measurement techniques[SOund Detection And Ranging

    Energy Technology Data Exchange (ETDEWEB)

    Antoniou, I.; Joergensen, H.E. [Risoe National Lab. (Denmark); Ormel, F. [Energy Research Center of the Netherlands (Netherlands); Bradley, S.; Huenerbein, S. von [University of Salford (United Kingdom); Emeis, S. [Forschungszentrum Karlsruhe GmbH (Germany); Warmbier, G. [GWU-Umwelttechnik Gmbh (Germany)

    2003-04-01

    The need for alternative means to measure the wind speed for wind energy purposes has increased with the increase of the size of wind turbines. The cost and the technical difficulties for performing wind speed measurements has also increased with the size of the wind turbines, since it is demanded that the wind speed has to be measured at the rotor centre of the turbine and the size of both the rotor and the hub height have grown following the increase in the size of the wind turbines. The SODAR (SOund Detection And Ranging) is an alternative to the use of cup anemometers and offers the possibility of measuring both the wind speed distribution with height and the wind direction. At the same time the SODAR presents a number of serious drawbacks such as the low number of measurements per time period, the dependence of the ability to measure on the atmospheric conditions and the difficulty of measuring at higher wind speeds due to either background noise or the neutral condition of the atmosphere. Within the WISE project (EU project number NNE5-2001-297), a number of work packages have been defined in order to deal with the SODAR. The present report is the result of the work package 1. Within this package the objective has been to present and achieve the following: 1) An accurate theoretic model that describes all the relevant aspects of the interaction of the sound beam with the atmosphere in the level of detail needed for wind energy applications. 2) Understanding of dependence of SODAR performance on hard- and software configuration. 3) Quantification of principal difference between SODAR wind measurement and wind speed measurements with cup anemometers with regard to power performance measurements.

  6. A sodar for profiling in a spatially inhomogeneous urban environment

    Directory of Open Access Journals (Sweden)

    Stuart Bradley

    2015-11-01

    Full Text Available The urban boundary layer, above the canopy, is still poorly understood. One of the challenges is obtaining data by sampling more than a few meters above the rooftops, given the spatial and temporal inhomogeneities in both horizontal and vertical. Sodars are generally useful tools for ground-based remote sensing of winds and turbulence, but rely on horizontal homogeneity (as do lidars in building up 3-component wind vectors from sampling three or more spatially separated volumes. The time taken for sound to travel to a typical range of 200 m and back is also a limitation. A sodar of radically different design is investigated, aimed at addressing these problems. It has a single vertical transmitted sound pulse. Doppler shifted signals are received from a number of volumes around the periphery of the transmitted beam with microphones which each having tight angular sensitivity at zenith angles slightly off-vertical. The spatial spread of sampled volumes is therefore smaller. By having more receiver microphones than a conventional sodar, the effect of smaller zenith angle is offset. More rapid profiling is also possible with a single vertical transmitted beam, instead of the usual multiple beams.A prototype design is described, together with initial field measurements. It is found that the beam forming using a single dish antenna and the drift of the sound pulse downwind both give rise to reduced performance compared with expectations. It is concluded that, while the new sodar works in principle, the compromises arising in the design mean that the expected advantages have not been realized

  7. Some aspects of estimation of mixing height using vertical sodar records

    Energy Technology Data Exchange (ETDEWEB)

    Walczewski, J. [Inst. for Meteorology and Water Management, Cracow (Poland)

    1997-10-01

    The changes of the vertical range of sodar, depending on technical parameters, were illustrated by resulting changes of the height distribution of convective and elevated layers echoes. The extent of the difference`s in vertical range may be compartively large. In analyzed case, the maximal heights of convective plumes recorded at the same site with use of 3 types of sodar, were like 1:1.35:1.96. The relations of mean centers of gravity of frequency distributions were like 1:1.4:2.4. (au)

  8. Errors in second moments estimated from monostatic Doppler sodar winds. II. Application to field measurements

    DEFF Research Database (Denmark)

    Gaynor, J. E.; Kristensen, Leif

    1986-01-01

    Observatory tower. The approximate magnitude of the error due to spatial and temporal pulse volume separation is presented as a function of mean wind angle relative to the sodar configuration and for several antenna pulsing orders. Sodar-derived standard deviations of the lateral wind component, before...

  9. Estimates of the height of the boundary layer using SODAR and rawinsoundings in Amazonia

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, G [Instituto de Aeronautica e Espaco (IAE/CTA), Sao Jose dos Campos, 12228-904 (Brazil); Santos, L A R dos [Instituto Nacional de Meteorologia (INMET), BrasIlia, 70680-900 (Brazil)], E-mail: gfisch@iae.cta.br, E-mail: landre@inmet.gov.br

    2008-05-01

    During the LBA campaign in Amazonia 2002, simultaneous measurements were made of the boundary layer using different instruments (rawinsoundings and SODAR). The profiles of potential temperature and humidity were used to estimates the height of the boundary layer using 3 different techniques. The SODAR's measurements did not capture the shallow morning boundary layer observed at the profiles.

  10. Doppler SODAR observations of the temperature structure ...

    Indian Academy of Sciences (India)

    67. (a). (b). Figure 2. Six hourly averaged zonal wind plots for the months of (a) April, (b) May, (c) June, and (d) July for 2007. been in continuous operation since January 2007 onwards. Anandan et al (2008) have described the technical specifications of the NARL SODAR sys- tem, signal processing, data quality control and.

  11. Tropospheric ozone lidar intercomparison experiment, TROLIX '91, field phase report

    International Nuclear Information System (INIS)

    Boesenberg, J.; Ancellet, G.; Bergwerff, H.; Cossart, G. v.; Fiedler, J.; Jonge, C. de; Mellqvist, J.; Mitev, V.; Sonnemann, G.; Swart, D.; Wallinder, E.

    1993-01-01

    The Tropospheric Ozone Lidar Intercomparison Experiment TROLIX '91 has been initiated as part of the TESLAS subproject of the cooperative programme EUROTRAC. It has been performed in June 1991 at the Rijksinstitut voor Volksgezondheid en Milieuhygiene (RIVM) in Bilthoven, The Netherlands. The experiment was based on the simultaneous operation of different types of differential absorption lidars (DIAL), a special version of a Differential Optical Absorption Spectroscopy Instrument (DOAS), helicopter borne in situ instruments, and many other supporting measurements. After a short introduction to the general methodology the instruments are described, the experimental operations are explained, and a selection of data are presented. Some examples are given for the results of the intercomparison, as far as they have been available at the present stage of evaluation. The main purpose of this report, however, is to provide an overview over the material collected during the experiment, on order to facilitate further detailed studies in cooperation between the different groups which have participated. (orig.)

  12. Multi-site testing and evaluation of remote sensing instruments for wind energy applications

    DEFF Research Database (Denmark)

    Sanz Rodrigo, J.; Borbon Guillen, F.; Gomez Arranz, P.

    2013-01-01

    A procedure for testing and evaluation of remote sensing instruments that makes use of two test sites in flat and complex terrain is presented. To illustrate the method, a system intercomparison experiment is presented involving one sodar and two lidars (pulsed and continuous-wave). The wind...

  13. Sodar measurements of the mixed-layer depth over a large city

    Energy Technology Data Exchange (ETDEWEB)

    Shurygin, E.A. [Russia Academy of Sciences, Inst. of Atmospheric Physics, Moscow (Russian Federation)

    1997-10-01

    The results of synchronous sodar`s measurements on a territory of city and suburban area have shown: (a) The types of stratification over centre of the city and periphery considerably differ, and these distinctions are more often displayed in morning and evening transition period. The agreement between types of stratification in the centre and on the periphery was observed in 40% of cases; (b) At equal temperature stratification the mixed-layer depth in centre of the city is about 50-150 m higher at inversions in comparison with a periphery, at advanced convection - these depths are identical; (c) At different stratification between the city and periphery the distinction in the mixed-layer depth can reach 200. (au)

  14. Boundary layer structure observed by Shipborne Doppler Sodar in the Suez Canal zone

    International Nuclear Information System (INIS)

    Fiocco, G.; Mastrantonio, G.; Ricotta, A.

    1980-01-01

    Observations of the boundary layer with a monostatic Sodar and other instrumentation were carried out in the Suez canal zone in January and March 1979, from the Italian m.v. Salernum on its way to and from a GARP assignment. The Sodar was operated almost continuously throughout the passages. In addition to the intensity records, an off-line Doppler analysis involving the use of the fast Fourier transform of the digitized Sodar echoes has provided the vertical component w of the velocity. In general, because of efficient filtering and of the good quality of the data, a vertical profile of w has been determined for each transmitted pulse. During a prolonged stay in the Bitter lakes vertical profiles of temperature and humidity were also obtained by deploying a tethered balloon. Large temporal and spatial temperature contrasts exist in the canal zone due to the presence of the desert and of large and small bodies of water. The ensuring phenomenology during the time of observation was quite varied. (author)

  15. SODAR measurements of inversions above the Rhine valley (Cologne and environment)

    Energy Technology Data Exchange (ETDEWEB)

    Dohrn, R.; Raschke, E.; Bujnoch, A.; Warmbier, G.

    1981-01-01

    During the time period of June 1978 to June 1980 the inversion heights have been measured continously with two SODARs of which one is located near the centre of Cologne and the other about 12 km northwest of it (rural environment). Verification measurements have been made in some cases with a balloon borne tethered sonde, and a pattern recognition method has been developed for automatic analysis of digitized SODAR records. In this paper are also presented statistical analysis of the annual and diurnal variation of probability of inversion occurence and height. Significant differences occure for the low level inversion structures over both stations while upper level inversions show large similarities. The inversion height depends to some degree also on the surface geostrophic wind speed.

  16. Design and results of the ice sheet model initialisation experiments initMIP-Greenland: an ISMIP6 intercomparison

    Science.gov (United States)

    Goelzer, Heiko; Nowicki, Sophie; Edwards, Tamsin; Beckley, Matthew; Abe-Ouchi, Ayako; Aschwanden, Andy; Calov, Reinhard; Gagliardini, Olivier; Gillet-Chaulet, Fabien; Golledge, Nicholas R.; Gregory, Jonathan; Greve, Ralf; Humbert, Angelika; Huybrechts, Philippe; Kennedy, Joseph H.; Larour, Eric; Lipscomb, William H.; Le clec'h, Sébastien; Lee, Victoria; Morlighem, Mathieu; Pattyn, Frank; Payne, Antony J.; Rodehacke, Christian; Rückamp, Martin; Saito, Fuyuki; Schlegel, Nicole; Seroussi, Helene; Shepherd, Andrew; Sun, Sainan; van de Wal, Roderik; Ziemen, Florian A.

    2018-04-01

    Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives) have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. The goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6), which is the primary activity within the Coupled Model Intercomparison Project Phase 6 (CMIP6) focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1) the initial present-day state of the ice sheet and (2) the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing) and in response to a large perturbation (prescribed surface mass balance anomaly); they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.

  17. Evaluation of REMTECH PA-2 phased array SODAR performance in Complex Terrain using in-situ turbulence instruments

    Energy Technology Data Exchange (ETDEWEB)

    Murray, D.R.; Catizone, P.A.; Hoffnagle, G.F. [TRC Environmental Corp., Windsor, CT (United States)

    1994-12-31

    The introduction of the Complex Terrain Dispersion Model Plus Algorithms for Unstable Situations (CTDMPLUS model) by the Environmental Protection Agency (EPA) has created a need for detailed vertical profiles of wind speed, direction and turbulence for regulatory modeling. Most EPA models use only a single level of wind data, assume wind direction within the boundary layer is uniform and extrapolate wind speed based on logarithmic profiles. CTDMPLUS offers a more realistic paradigm for transport and dispersion in the boundary layer by utilizing measured wind profiles if available. Profile data used by CTDMPLUS must include the layer in which the plume is dispersing. For tall stack, heated effluent plume, the profile must extend to heights of several hundred meters above stack top. Doppler SOund Detection And Ranging (SODAR) systems provide a cost effective method for collecting the profile data. While EPA has approved the use of mean wind speed and direction data from SODARs for regulatory modeling purposes, the use of turbulence data has not been unconditionally accepted. In order to use turbulence data from a SODAR, the user must obtain concurrence from the agency that the turbulence data are acceptable and may be required to demonstrate that the data are reliable. This paper presents the results of a SODAR data evaluation project.

  18. A bistatic sodar for precision wind profiling in complex terrain

    DEFF Research Database (Denmark)

    Bradley, Stuart; Hünerbein, Sabine Von; Mikkelsen, Torben

    2012-01-01

    A new ground-based wind profiling technology-a scanned bistatic sodar-is described. The motivation for this design is to obtain a "mastlike"wind vector profile in a single atmospheric column extending from the ground to heights of more than 200 m. The need for this columnar profiling arises from ...

  19. On the theory of SODAR measurement techniques

    DEFF Research Database (Denmark)

    Antoniou, I.; Ejsing Jørgensen, Hans; Bradley, S.

    2003-01-01

    The need for alternative means to measure the wind speed for wind energy purposes has increased with the increase of the size of wind turbines. The cost and the technical difficulties for performing wind speed measurements has also increased with the sizeof the wind turbines, since it is demanded...... the objective has been to present and achieve thefollowing: An accurate theoretic model that describes all the relevant aspects of the interaction of the sound beam with the atmosphere in the level of detail needed for wind energy applications. Understanding of dependence of SODAR performance on hard...

  20. The bistatic sodar 'Heimdall', you blow, I listen

    Energy Technology Data Exchange (ETDEWEB)

    Mikkelsen, Torben; Joergensen, Hans E.; Kristensen, Leif

    2007-11-15

    With the increased exploitation of wind energy, remote sensing of wind profiles in the atmospheric boundary layer has come in focus as an attractive alternative to the operation of tall instrumented masts for wind energy siting and assessment studies. Project 'Heimdall' describes a recent feasibility study conducted at Risoe in the period 2001-2003 of the investigation of a new continuous wave (CW) bistatic sodar, initiated with the aim of investigating and improving the measuring accuracy of sodar remote sensing at heights ranging between 50 and 150 meters, during the often strong wind conditions in a neutrally stratified atmospheric conditions, characteristic for wind energy applications. Here we first describe the theoretical developments for sound wave scattering theory within a bistatic configuration. We calculate the Doppler shifts and returned power for the proposed new Heimdall bistatic configuration, implemented for measurements at 60 meters height above the ground. The bistatic 'Heimdall' sodar was subsequently built and set in operation adjacent to the 123 meter tall met tower at Risoe National Laboratory, which we had equipped with a sonic reference anemometer installed at the 60 meters height. 'Heimdall' measured CW Doppler shifts, subsequently processed into wind speed in real time, along with received power which have been compared with our predictions, and we found that: (1) Our suggested bi-static configuration enabled real-time tracing of the wind speeds with data rates of {approx}1 Hz from fast processing of the measured spectral measurements of the Doppler shift with an adequate signal-to- noise ratio, and (2) the amplitudes of the measured return powers compared to the predictions within about -10 dB. We conclude that the proposed bi-static configuration provides significantly improved signal-to-noise advantages over similar mono-static configurations, and thereby also better data availability rates for wind speed

  1. Wind climatology observed over Kalpakkam using Doppler sodar

    International Nuclear Information System (INIS)

    Narayana Rao, D.; Krishna Reddy, K.; Vijaya Kumar, T.R.; Kishore, P.

    1996-01-01

    Acoustic remote sensing of the prevailing winds in the boundary layer finds an important application in studying the problems related to air pollution meteorology. Analysis of the seasonal variation of vertical and horizontal wind speed with altitude is made using the Doppler sodar data collected at an atomic research centre, Kalpakkam. A pictorial representation of horizontal wind flow for each season is given in the form of wind roses at three lower levels of probing, namely 100, 300 and 500 m. Such analysis would prove to be a basic reference material for taking necessary meaningful emergency measures in similar climatic regions. (author). 18 refs., 10 figs

  2. Sodar study of the characteristics of presumable big toroid structures above an overheated surface

    International Nuclear Information System (INIS)

    Valery, K

    2008-01-01

    A set of sodars allowed to investigate the spatial variability of meso-scale organized structures under conditions of strong convection and weak wind. The distribution of velocity within the structures and the structure typical sizes have been determined as a result of processing of experimental data

  3. Atmospheric Correction Inter-Comparison Exercise

    Directory of Open Access Journals (Sweden)

    Georgia Doxani

    2018-02-01

    Full Text Available The Atmospheric Correction Inter-comparison eXercise (ACIX is an international initiative with the aim to analyse the Surface Reflectance (SR products of various state-of-the-art atmospheric correction (AC processors. The Aerosol Optical Thickness (AOT and Water Vapour (WV are also examined in ACIX as additional outputs of AC processing. In this paper, the general ACIX framework is discussed; special mention is made of the motivation to initiate the experiment, the inter-comparison protocol, and the principal results. ACIX is free and open and every developer was welcome to participate. Eventually, 12 participants applied their approaches to various Landsat-8 and Sentinel-2 image datasets acquired over sites around the world. The current results diverge depending on the sensors, products, and sites, indicating their strengths and weaknesses. Indeed, this first implementation of processor inter-comparison was proven to be a good lesson for the developers to learn the advantages and limitations of their approaches. Various algorithm improvements are expected, if not already implemented, and the enhanced performances are yet to be assessed in future ACIX experiments.

  4. Intercomparison of alpha particle spectrometry software packages

    International Nuclear Information System (INIS)

    1999-08-01

    Software has reached an important level as the 'logical controller' at different levels, from a single instrument to an entire computer-controlled experiment. This is also the case for software packages in nuclear instruments and experiments. In particular, because of the range of applications of alpha-particle spectrometry, software packages in this field are often used. It is the aim of this intercomparison to test and describe the abilities of four such software packages. The main objectives of the intercomparison were the ability of the programs to determine the peak areas and the peak area uncertainties, and the statistical control and stability of reported results. In this report, the task, methods and results of the intercomparison are presented in order to asist the potential users of such software and to stimulate the development of even better alpha-particle spectrum analysis software

  5. Variation of vertical atmospheric stability by means of radon measurements and of sodar monitoring

    International Nuclear Information System (INIS)

    Guedalia, D.; Druilhet, A.; Fontan, J.; N'tsila, A.

    1980-01-01

    Continuous measurements of radon at ground level are used to infer variations in equivalent mixing height and atmospheric vertical stability. Simultaneous determinations of the height of the inversion layer, when present, permit, with the use of sodar techniques, the estimation of radon flux from the ground and of the vertical diffusion coefficient. The two sets of data often indicate similar variations in mixing height

  6. Sonic Detection and Ranging (SODAR) Wind Profiler Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Coulter, Richard L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-04-01

    The SODAR (Sonic Detection and Ranging) wind profiler measures wind profiles and backscattered signal strength between (nominally) 15 meters (m) and 500 m. It operates by transmitting acoustic energy into the atmosphere and measuring the strength and frequency of backscattered energy. The strength of the backscattered signal is determined by the strength of temperature inhomogeneities with size on the order of 10 centimeters (cm). Assuming the scattering elements in the atmosphere are moving with the mean wind, the horizontal wind field can be derived. The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) has a system developed by Scintec, Inc. that transmits a sequence of frequencies to enhance signal determination.

  7. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    Science.gov (United States)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  8. Intercomparison Measurements Exercises of Mobile Radiological Laboratories (invited paper)

    International Nuclear Information System (INIS)

    Martincic, R.

    2000-01-01

    After the reactor accident in Chernobyl, the importance of mobile radiological laboratories became evident and in situ gamma spectrometry became a common method for the rapid detection of gamma emitters in the environment. Since then different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the measurement methods and the preparedness of emergency monitoring teams. The general objectives of these workshops are to promote the knowledge and to exchange the experiences of emergency monitoring teams that use mobile radiological laboratories, as well as to foster the international harmonisation of emergency monitoring procedures and cooperation among teams. Finally, the results of intercomparison measurements have shown that such exercises are mandatory for rapid, efficient and correct environmental monitoring in nuclear or radiological emergencies. An overview of these intercomparison measurements is given, results from the 1999 intercomparison workshop are presented and lessons learned are discussed. (author)

  9. The Myres Hill remote sensing intercomparison study: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Clive, P J M; Chindurza, I [SgurrEnergy Ltd, 79 Coplaw Street, Glasgow G42 7JG, Scotland (United Kingdom); Ravey, I; Bass, J [RES Group Ltd, James Blyth House, 7000 Academy Park, Glasgow, Scotland (United Kingdom); Boyle, R J; Jones, P [TUV NEL Ltd, East Kilbride, Glasgow G75 0QF, Scotland (United Kingdom); Lang, S J [Sustainable Energy Research Group, University College Cork (Ireland); Bradley, S [Mighty River Power, Level 14, 23-29 Albert Street, Auckland (New Zealand); Hay, L [Garrad Hassan and Partners Ltd, 2064 Maryhill Road, Glasgow G20 0AB, Scotland (United Kingdom); Oldroyd, A [Oldbaum Services Ltd, Schoolhouse, Brig o' Turk, Callander, Scotland (United Kingdom); Stickland, M [University of Strathclyde, 16 Richmond Street, Glasgow G1 1XQ, Scotland (United Kingdom)], E-mail: peter.clive@sgurrenergy.com

    2008-05-01

    Two remote sensing techniques (SODAR and LIDAR) have been developed for measuring wind speed and turbulence from ground level up to altitudes of 300 m or higher. Although originally developed in the defence sector, these techniques are now generating considerable interest in the renewable energy and meteorological sectors. Despite the benefits of these instruments they are not yet generally accepted for due diligence measurements by wind energy developers and financial institutions. There is a requirement for a series of independent assessments of these new metrology techniques, comparing their measurements with the approved cup-type anemometer readings. This is being addressed at TUV NEL's Myres Hill wind turbine test site in a measurement programme supported by the DIUS National Measurement Systems Measurement for Innovators scheme and a consortium of 21 industrial collaborators. Data from SODAR and LIDAR systems are being compared with results from cup-type anemometers mounted at different heights on an 80m meteorological mast. An ultrasonic sensor is also mounted on the mast. The objective of the test programme is to assess the effectiveness of SODAR and LIDAR wind speed measurement techniques under different operating regimes and atmospheric conditions. Results from the measurements will provide definitive data on the performance of the remote wind speed sensing techniques under test on complex terrain typical of many wind farm sites. Preliminary measurements based on data acquired during the initial measurement campaign are presented.

  10. Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment - special observation period (hymex-sop1)

    Science.gov (United States)

    Summa, Donato; Di Girolamo, Paolo; Flamant, Cyrille; De Rosa, Benedetto; Cacciani, Marco; Stelitano, Dario

    2018-04-01

    Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL), an airborne DIAL (LEANDRE2), a microwave radiometer, radiosondes and aircraft in-situ sensors.

  11. Optimal interpolation method for intercomparison of atmospheric measurements.

    Science.gov (United States)

    Ridolfi, Marco; Ceccherini, Simone; Carli, Bruno

    2006-04-01

    Intercomparison of atmospheric measurements is often a difficult task because of the different spatial response functions of the experiments considered. We propose a new method for comparison of two atmospheric profiles characterized by averaging kernels with different vertical resolutions. The method minimizes the smoothing error induced by the differences in the averaging kernels by exploiting an optimal interpolation rule to map one profile into the retrieval grid of the other. Compared with the techniques published so far, this method permits one to retain the vertical resolution of the less-resolved profile involved in the intercomparison.

  12. Experiences of ZAMG on mixing height determination

    Energy Technology Data Exchange (ETDEWEB)

    Piringer, M. [Zentralanstalt fuer Meteorologie und Geodynamik, ZAMG, Vienna (Austria)

    1997-10-01

    Temperature inversions in the boundary layer occur quite often, esp. in mountainous terrain by which Austria is covered to a large extent, and can lead to enhanced pollution at the surface because the air volume available for dilution is then vertically limited. The Department of Environmental Meteorology of ZAMG therefore set up several field programs in the past to study such conditions at a variety of sites in Austria, using tethersondes and Sodars. Early investigations aimed at comparing Sodar echo profiles to the tethersonde temperature profiles to derive mixing heights from the Sodar echo structure. More recently, evolving from KONGEX, the `convective boundary layer experiment`, mixing heights calculated for Vienna by the OML model were compared to those derived from radiosonde and tethersonde potential temperature profiles. Results of these investigations will be presented, focussing on the problems when using the different methods. New efforts to derive mixing heights from data were also undertaken and are discussed separately. (au)

  13. Water vapour inter-comparison effort in the framework of the hydrological cycle in the mediterranean experiment – special observation period (hymex-sop1

    Directory of Open Access Journals (Sweden)

    Summa Donato

    2018-01-01

    Full Text Available Accurate measurements of the vertical profiles of water vapour are of paramount importance for most key areas of atmospheric sciences. A comprehensive inter-comparison between different remote sensing and in-situ sensors has been carried out in the frame work of the first Special Observing Period of the Hydrological cycle in the Mediterranean Experiment for the purpose of obtaining accurate error estimates for these sensors. The inter-comparison involves a ground-based Raman lidar (BASIL, an airborne DIAL (LEANDRE2, a microwave radiometer, radiosondes and aircraft in-situ sensors.

  14. The program of international intercomparison of accident dosimetry

    International Nuclear Information System (INIS)

    2002-06-01

    The French institute of radioprotection and nuclear safety (IRSN) has carried out in June 2002 an international intercomparison program for the testing of the physical and biological accident dosimetry techniques. The intercomparison is jointly organized by the IRSN and the OECD-NEA with the sustain of the European commission and the collaboration of the CEA centre of Valduc (France). About 30 countries have participated to this program. Each country has supplied its own dosimeters and biological samples which have been irradiated using the Silene reactor of CEA-Valduc or a 60 Co source. These experiments allow to test the new dosimetric techniques that have been developed since the previous intercomparison program (1993) and to confirm or improve the performances of older techniques. Aside from the intercomparison exercise, this report makes a status of the known radiological accidents and of the effects of high doses of ionizing radiations on human health (symptoms, therapeutics). It explains the phenomenology of criticality accidents, the prevention means, and the history of such accidents up to the Tokai-Mura one in 1999. Finally, the dosimetry of criticality is presented with its physical and biological techniques. (J.S.)

  15. Measurements of the Temperature Structure-Function Parameters with a Small Unmanned Aerial System Compared with a Sodar

    Science.gov (United States)

    Bonin, Timothy A.; Goines, David C.; Scott, Aaron K.; Wainwright, Charlotte E.; Gibbs, Jeremy A.; Chilson, Phillip B.

    2015-06-01

    The structure function is often used to quantify the intensity of spatial inhomogeneities within turbulent flows. Here, the Small Multifunction Research and Teaching Sonde (SMARTSonde), an unmanned aerial system, is used to measure horizontal variations in temperature and to calculate the structure function of temperature at various heights for a range of separation distances. A method for correcting for the advection of turbulence in the calculation of the structure function is discussed. This advection correction improves the data quality, particularly when wind speeds are high. The temperature structure-function parameter can be calculated from the structure function of temperature. Two case studies from which the SMARTSonde was able to take measurements used to derive at several heights during multiple consecutive flights are discussed and compared with sodar measurements, from which is directly related to return power. Profiles of from both the sodar and SMARTSonde from an afternoon case exhibited generally good agreement. However, the profiles agreed poorly for a morning case. The discrepancies are partially attributed to different averaging times for the two instruments in a rapidly evolving environment, and the measurement errors associated with the SMARTSonde sampling within the stable boundary layer.

  16. Improved set of criticality accident detectors used in the intercomparison experiment in Valduc

    International Nuclear Information System (INIS)

    Jozefowicz, K.; Golnik, N.

    1996-01-01

    An improved set of critically accident detectors has been elaborated for the needs of the Inst. of Atomic Energy in Swierk. The sets, which consist of fission track detectors, wide-base silicon diodes and RPL glasses, were tested in the international intercomparison experiment in Valduc, France. Comparison of our results with the reference measurements showed a good agreement (within 25%) for both the neutron and gamma measurements. Additionally, the diode response to neutron kerma was investigated more extensively in the dose range between 2 and 10 Gy, where the dependence of the diode signal versus neutron kerma was not well known. A possibility of the multiple use of the diodes has been proved. (author)

  17. Analysis of laboratory intercomparison data: a matter of independence

    Directory of Open Access Journals (Sweden)

    Mauro F. Rebelo

    2003-05-01

    Full Text Available When laboratory intercomparison exercises are conducted, there is no a priori dependence of the concentration of a certain compound determined in one laboratory to that determined by another(s. The same applies when comparing different methodologies. A existing data set of total mercury readings in fish muscle samples involved in a Brazilian intercomparison exercise was used to show that correlation analysis is the most effective statistical tool in this kind of experiments. Problems associated with alternative analytical tools such as mean or paired 't'-test comparison and regression analysis are discussed.

  18. Mobile Radiological Laboratories Intercomparison Measurements - Chernobyl

    International Nuclear Information System (INIS)

    Martincic, R.; Glavic-Cindro, D.; Korun, M.; Pucelj, B.; Vodenik, B.

    2001-01-01

    Full text: In last decade different institutions in European countries have organised periodic intercomparison exercises of mobile radiological laboratories to improve the preparedness of emergency monitoring teams. The 12th Regular Workshop on Mobile Radiological Laboratories was held in Exclusion Zone of the Chernobyl NPP, Ukraine from September 13 to September 18, 1999 under the acronym MORAL-12. The European Centre of Technological Safety (TESEC), Kiev, Ukraine and J. Stefan Institute, Ljubljana, Slovenia organised Intercomparison Measurements 99 jointly under the auspices of the International Atomic Energy Agency (IAEA). Nineteen teams from 9 countries and IAEA participated in the Workshop. Six field and personal and equipment contamination control exercises were prepared and conducted at two measuring sites with very different ambient dose rate levels. The Workshop pointed out that such exercises are very valuable for rapid, efficient and harmonised emergency response in case of nuclear or radiological emergency. The teams had an opportunity to test their ability to perform field measurements in the contaminated environment, and to report results on the spot, as well as to test their emergency preparedness and persistence. They gained new experiences for fieldwork under stress conditions. An overview and results of these intercomparison measurements are presented and lessons learned are discussed. (author)

  19. Dose intercomparison studies for standardization of high-dose dosimetry in Viet Nam

    International Nuclear Information System (INIS)

    Mai Hoang Hoa; Duong Nguyen Dinh; Kojima, T.

    1999-01-01

    The Irradiation Center of the Vietnam Atomic Energy Commission (IC-VAEC) is planning to establish a traceability system for high-dose dosimetry and to provide high-dose standards as a secondary standard dosimetry laboratory (SSDL) level in Vietnam. For countries which do not have a standard dosimetry laboratory, the participation in the International Dose Assurance Service (IDAS) operated by the International Atomic Energy Agency (IAEA) is the most common means to verify own dosimetry performance with a certain uncertainty. This is, however, only one-direction dose intercomparison with evaluation by IAEA including unknown parameter at participant laboratories. The SSDL level laboratory should have traceability as well as compatibility, ability to evaluate uncertainties of its own dosimetry performance by itself In the present paper, we reviewed our dosimetry performance through two-way dose intercomparison studies and self-evaluation of uncertainty in our dosimetry procedure. The performance of silver dichromate dosimeter as reference transfer dosimeter in IC-VAEC was studied through two-way blind dose intercomparison experiments between the IC-VAEC and JAERI. As another channel of dose intercomparison with IAEA, alanine dosimeters issued by IDAS were simultaneously irradiated with the IC-VAEC dichromate dosimeters at IC-VAEC and analyzed by IAEA. Dose intercomparison between IC-VAEC and JAERI results into a good agreement (better than ±2.5%), and IDAS results also show similar agreement within ±3.0%. The uncertainty was self-estimated on the basis of the JAERI alanine dosimetry, and a preliminary value of about 1.86% at a 68% confidence level is established. The results from these intercomparisons and our estimation of the uncertainty are consistent. We hope that our experience is valuable to other countries which do not have dosimetry standard laboratories and/or are planning to establish them. (author)

  20. An international intercomparison of passive dosemeters, electronic dosemeters and dose rate meters used for environmental radiation measurements

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Thompson, I.M.G.

    1995-01-01

    during 1994. The intercomparison was organised by the Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany, and by the Riso National Laboratory, Roskilde, Denmark. This paper describes the intercomparison experiments performed at the newly established Riso Natural Environmental Radiation...

  1. Design and results of the ice sheet model initialisation initMIP-Greenland: an ISMIP6 intercomparison

    Directory of Open Access Journals (Sweden)

    H. Goelzer

    2018-04-01

    Full Text Available Earlier large-scale Greenland ice sheet sea-level projections (e.g. those run during the ice2sea and SeaRISE initiatives have shown that ice sheet initial conditions have a large effect on the projections and give rise to important uncertainties. The goal of this initMIP-Greenland intercomparison exercise is to compare, evaluate, and improve the initialisation techniques used in the ice sheet modelling community and to estimate the associated uncertainties in modelled mass changes. initMIP-Greenland is the first in a series of ice sheet model intercomparison activities within ISMIP6 (the Ice Sheet Model Intercomparison Project for CMIP6, which is the primary activity within the Coupled Model Intercomparison Project Phase 6 (CMIP6 focusing on the ice sheets. Two experiments for the large-scale Greenland ice sheet have been designed to allow intercomparison between participating models of (1 the initial present-day state of the ice sheet and (2 the response in two idealised forward experiments. The forward experiments serve to evaluate the initialisation in terms of model drift (forward run without additional forcing and in response to a large perturbation (prescribed surface mass balance anomaly; they should not be interpreted as sea-level projections. We present and discuss results that highlight the diversity of data sets, boundary conditions, and initialisation techniques used in the community to generate initial states of the Greenland ice sheet. We find good agreement across the ensemble for the dynamic response to surface mass balance changes in areas where the simulated ice sheets overlap but differences arising from the initial size of the ice sheet. The model drift in the control experiment is reduced for models that participated in earlier intercomparison exercises.

  2. Characteristics of nocturnal coastal boundary layer in Ahtopol based on averaged SODAR profiles

    Science.gov (United States)

    Barantiev, Damyan; Batchvarova, Ekaterina; Novitzky, Mikhail

    2014-05-01

    The ground-based remote sensing instruments allow studying the wind regime and the turbulent characteristics of the atmosphere with height, achieving new knowledge and solving practical problems, such as air quality assessments, mesoscale models evaluation with high resolution data, characterization of the exchange processes between the surface and the atmosphere, the climate comfort conditions and the risk for extreme events, etc. Very important parameter in such studies is the height of the atmospheric boundary layer. Acoustic remote sensing data of the coastal atmospheric boundary layer were explored based on over 4-years continuous measurements at the meteorological observatory of Ahtopol (Bulgarian Southern Black Sea Coast) under Bulgarian - Russian scientific agreement. Profiles of 12 parameters from a mid-range acoustic sounding instrument type SCINTEC MFAS are derived and averaged up to about 600 m according filtering based on wind direction (land or sea type of night fowls). From the whole investigated period of 1454 days with 10-minute resolution SODAR data 2296 profiles represented night marine air masses and 1975 profiles represented the night flow from land during the months May to September. Graphics of averaged profiles of 12 SODAR output parameters with different availability of data in height are analyzed for both cases. A marine boundary-layer height of about 300 m is identified in the profiles of standard deviation of vertical wind speed (σw), Turbulent Kinetic Energy (TKE) and eddy dissipation rate (EDR). A nocturnal boundary-layer height of about 420 m was identified from the profiles of the same parameters under flows from land condition. In addition, the Buoyancy Production (BP= σw3/z) profiles were calculated from the standard deviation of the vertical wind speed and the height z above ground.

  3. ESCOMPTE experiment: intercomparison of four aircraft dynamical, thermodynamical, radiation and chemical measurements

    Science.gov (United States)

    Saïd, F.; Corsmeier, U.; Kalthoff, N.; Kottmeier, C.; Lothon, M.; Wieser, A.; Hofherr, T.; Perros, P.

    2005-03-01

    Among seven airplanes involved in the Experience sur Site pour COntraindre les Modèles de Pollution atmosphérique et de Transport d'Emission (ESCOMPTE) experiment in 2001, four measured classical meteorological parameters, radiation fluxes, trace gases and turbulence (for three among four): the Dornier 128 from the Institut für Meteorologie und Klimaforschung, the Fokker 27 ARAT from the Institut National des Sciences de l'Univers, the Merlin 4 and Piper Aztec 23 from Météo France. This paper presents the results of intercomparison flights between three pairs of aircraft. The results are very similar for mean parameters except for the horizontal wind measurements provided by the Merlin that showed a problem that is probably linked to the measurement of the aircraft velocity. Further investigation is required to know whether corrections are possible or not for these wind measurements. Turbulence is studied along two legs over a flat and homogeneous area: in spite of the heterogeneity of the measured functions (one leg is close to the top of the boundary layer), the comparison is rather good. The relative accuracy of the data provided to the data base is given. It easily allows to use the huge amount of aircraft data collected during the experiment with very few restrictions. We underline some points where efforts should be borne for future experiments: wind coupling between Inertial Navigation System data and Global Positioning System (GPS) data, CO and NO x measurements.

  4. Intercomparison of Environmental Nuclear Radiation Measuring

    Institute of Scientific and Technical Information of China (English)

    GAO; Fei; NI; Ning; HOU; Jin-bing; SONG; Ming-zhe

    2015-01-01

    In 2015,Radiation Metrology Division of China Institute of Atomic Energy organized an environmental monitoring of nuclear radiation measuring intercomparison,and 9laboratories attended.The intercomparison included environmental level dosemeters and protection level

  5. Some parameterization formulae for mixing height compared with joint sodar and lidar observations

    Energy Technology Data Exchange (ETDEWEB)

    Bielak, A.; Burzynski, J.; Kaszowski, W.; Walczewski, J. [Inst. for Meteorology and Water Management, Cracow (Poland)

    1997-10-01

    The mixing height (MH) is most frequently defined in terms of the mixing mechanism: atmospheric turbulence and its variability versus height. From the practical point of view it is more important to know the height of mixing of real polluting substances, than the absolute ceiling of turbulent processes. This approach is followed by many authors, especially those using lidars for observations of aerosol or gas mixing. In this paper effort is made to bring some contribution to these studies. The paper presents the results of selected observations of aerosol mixing height, compared with sodar observations of BL structure and with the MH calculated with use of different formulae taken from literature. All measurements were made in Cracow, Poland. (LN) 20 refs.

  6. The Geoengineering Model Intercomparison Project (GeoMIP)

    KAUST Repository

    Kravitz, Ben

    2011-01-31

    To evaluate the effects of stratospheric geoengineering with sulphate aerosols, we propose standard forcing scenarios to be applied to multiple climate models to compare their results and determine the robustness of their responses. Thus far, different modeling groups have used different forcing scenarios for both global warming and geoengineering, complicating the comparison of results. We recommend four experiments to explore the extent to which geoengineering might offset climate change projected in some of the Climate Model Intercomparison Project 5 experiments. These experiments focus on stratospheric aerosols, but future experiments under this framework may focus on different means of geoengineering. © 2011 Royal Meteorological Society.

  7. Intercomparison exercises

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2007-01-01

    Intercomparison exercises are vital to many a national programmes. These are only tools available with the laboratories to prove their competence to an international audience and also for the accrediting agencies to assess a laboratory

  8. Research of the arid aerosol carrying out with a help of a set of sodars

    International Nuclear Information System (INIS)

    Valery, K; Igor, G

    2008-01-01

    Study of spatial and vertical distribution of vertical wind velocity was carried out in the 'Har-Gzyr 2007' field program in the 'Black Sands' region, Russia, with the help of four sodars. Continuous (about half an hour) and stable anabatic motions of the air were revealed for altitudes 10m to 800m over the area of some square kilometres. The measured vertical speed reached 2m/s. Permanent and quick transfer of sub-micron aerosol particles from the surface layer to the troposphere can be explained by this phenomenon. The scheme is proposed to design a mass balance equation to calculate aerosol concentration in the upper layers of the ABL

  9. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  10. Results of the IAEA/RCA personal dosemeter intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Momose, Takumaro; Hayashi, Naomi [Environment and Safety Division, Tokai Works, Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2000-06-01

    The intercomparison of personal dosemeters for photon was carried out between 1990 and 1996 as part of the IAEA/RCA 'strengthening of radiation protection infrastructure' project. Japan Nuclear Cycle Development Institute participated in the intercomparison as one of the in-house personal dosimetry service organizations in Japan and also served the host irradiating laboratory. This report summarizes the dose evaluation results obtained from the JNC-TLD badges in the past four intercomparison programs. In the latest intercomparison the evaluated doses agreed to the reference doses with an accuracy of 10%. (author)

  11. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ( 252 Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ( 252 Cf at 45 ) or for simulated workplace fields ( 252 Cf(D 2 O) or 252 Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection principle on which the

  12. Intercomparison exercises - a 'must' or a 'need'

    International Nuclear Information System (INIS)

    Paraschiva, Mircea-Valentin; Cherestes, Margareta; Cherestes, Codrut

    2011-01-01

    The national legislation and the IAEA's Basic Safety Standards Series require the implementation of a QA programme for approval of dosimetry services. The implementation of a quality system according to EN ISO/IEC17025:2005 standard is a way to demonstrate that the dosimetry service is technically competent and capable of generating technically valid results. There are around fifty different standards relevant to individual monitoring, which indicates the complexity and difficulty of understanding and using the appropriate standard in routine work. The new recommendations published by European Commission - RP-160 - bring together requirements and guidance given in 96/29/EURATOM Directive, ICRP Publications, ICRU Reports and IAEA technical documents. The aim of these recommendations is to address the growing need for improvement and harmonization of practices and procedures used in individual dosimetry, for a mutual recognition of dose assessments performed by Approved Dosimetry Services across Europe. An intercomparison exercise among dosimetry services is like a performance test. The results of intercomparisons are published but anonimized. In many Member States participation in international intercomparisons is strongly recommended as results can be used to support an application for approval or accreditation. In this paper we present the results of our participation in two intercomparison exercises: EURADOS Intercomparison 2008 and EURADOS Intercomparison 2010. The results are displayed using the 'trumpet curves' (ISO 14146). The corrective actions are presented and also the lessons learned. At first exercise, in 2008, we have participated with one dosimetric system - photographic dosemeter - and at the second one, we have participated with two dosimetric systems: photographic and thermoluminescent. (authors)

  13. Results of the European Community's beta intercomparison programme of individual dosemeters in 1986

    International Nuclear Information System (INIS)

    Bigard, T.; Sequin, H.; Chartier, J.L.; Christensen, P.; Francis, T.M.; Lembo, L.

    1988-01-01

    For over 20 years, the Commission of the European Communities, in collaboration with competent laboratories in the member states, has been conducting intercomparisons of individual dosemeters with the objective of improving technique for monitoring ionizing radiation and establishing a common basis for dose assessment within the Community. These programmes not only serve the participants with an opportunity to validate their calibration and measuring procedures but also help to create a forum in which to exchange information and discuss experience with other participants. The performance and results of such an intercomparison exercise conducted in 1986 are reported here

  14. First intercomparison exercise in the frame of the coordinated investigation program of the IAEA on regional intercomparison of personal dosimetry

    International Nuclear Information System (INIS)

    Massera, G.; Papadopulos, S.B.; Gregori, B.N.; DaSilva, T.; Griffith, R.; )

    1998-01-01

    During the days 7 and 11 of October of 1996 took place in Buenos Aires, Argentina, the first Meeting of the Coordinated Investigation program of the IAEA on Regional Intercomparison of Personal Dosimetry for Latin American. In this meeting participated nine representatives of reference laboratories and of personal dosimetry of the region. Fundamental aspect of personal dosimetry relates with the quantity personal dose equivalent Hp application and the implementation of intercomparison exercise in order to improve the quality of the dose estimation have been discussed. Also lectures carried out by the specialist on Hp and practical aspects of it implementation; answer and calibration according to the ISO 4037; intercomparison methods: procedures and organizations. It was carried out the first intercomparison exercise where the participants collaborated in the preparations and irradiations of personal dosemeters they have brought. (author)

  15. Design of the MISMIP+, ISOMIP+, and MISOMIP ice-sheet, ocean, and coupled ice sheet-ocean intercomparison projects

    Science.gov (United States)

    Asay-Davis, Xylar; Cornford, Stephen; Martin, Daniel; Gudmundsson, Hilmar; Holland, David; Holland, Denise

    2015-04-01

    The MISMIP and MISMIP3D marine ice sheet model intercomparison exercises have become popular benchmarks, and several modeling groups have used them to show how their models compare to both analytical results and other models. Similarly, the ISOMIP (Ice Shelf-Ocean Model Intercomparison Project) experiments have acted as a proving ground for ocean models with sub-ice-shelf cavities.As coupled ice sheet-ocean models become available, an updated set of benchmark experiments is needed. To this end, we propose sequel experiments, MISMIP+ and ISOMIP+, with an end goal of coupling the two in a third intercomparison exercise, MISOMIP (the Marine Ice Sheet-Ocean Model Intercomparison Project). Like MISMIP3D, the MISMIP+ experiments take place in an idealized, three-dimensional setting and compare full 3D (Stokes) and reduced, hydrostatic models. Unlike the earlier exercises, the primary focus will be the response of models to sub-shelf melting. The chosen configuration features an ice shelf that experiences substantial lateral shear and buttresses the upstream ice, and so is well suited to melting experiments. Differences between the steady states of each model are minor compared to the response to melt-rate perturbations, reflecting typical real-world applications where parameters are chosen so that the initial states of all models tend to match observations. The three ISOMIP+ experiments have been designed to to make use of the same bedrock topography as MISMIP+ and using ice-shelf geometries from MISMIP+ results produced by the BISICLES ice-sheet model. The first two experiments use static ice-shelf geometries to simulate the evolution of ocean dynamics and resulting melt rates to a quasi-steady state when far-field forcing changes in either from cold to warm or from warm to cold states. The third experiment prescribes 200 years of dynamic ice-shelf geometry (with both retreating and advancing ice) based on a BISICLES simulation along with similar flips between warm and

  16. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ({sup 252}Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ({sup 252}Cf at 45 ) or for simulated workplace fields ({sup 252}Cf(D{sub 2}O) or {sup 252}Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection

  17. RCA/IAEA third external dosimetry intercomparisons in East Asia region

    International Nuclear Information System (INIS)

    Yamamoto, H.; Yoshizawa, M.; Murakami, H.; Momose, T.; Tsujimura, N.; Kanai, K.; Cruz-Suarez, R.

    2007-01-01

    Several intercomparison exercises were organised by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or inter-regional basis. In East Asia region, a third phase of the intercomparison finished in mid 2004. It was organised within the frame of the Regional Cooperation Agreement (RCA) as a follow-up to previous exercises carried out during 1990-1992 and 1995-1996. The results of this intercomparison for the determination of operational quantities were satisfactory for all Member States. The laboratories demonstrated a good performance in quantities tested. The purpose of this paper is to present the results of the RCA/IAEA intercomparison and the future of RCA activities in support of assessment of occupational exposure by organising intercomparison runs. (authors)

  18. Intercomparison of gamma ray analysis software packages

    International Nuclear Information System (INIS)

    1998-04-01

    The IAEA undertook an intercomparison exercise to review available software for gamma ray spectra analysis. This document describes the methods used in the intercomparison exercise, characterizes the software packages reviewed and presents the results obtained. Only direct results are given without any recommendation for a particular software or method for gamma ray spectra analysis

  19. On the methodology of the intercomparison of TND evaluations

    International Nuclear Information System (INIS)

    Yiftah, S.; Caner, M.; Gur, Y.

    1979-03-01

    The paper presents the problems which arise when two independent complete nuclear data evaluations of the same nuclide are available. A detailed intercomparison of the evaluations can be a multi-levelled exercise of considerable detail, the stages of which cannot always be performed. However, a detailed intercomparison can be a rich source for improving considerably the nuclear data used for the different applications. Preliminary examples of intercomparison are given for illustrative purpose. (B.G.)

  20. Electron spin resonance intercomparison studies on irradiated foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Raffi, J [CEA Centre d` Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (FR)

    1992-07-01

    The results of intercomparison studies organized by the Community Bureau of Reference on the use of electron spin resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. A quantitative intercomparison involving the use of poultry bones was also organized. There was no difficulty in identifying meat bones, dried grapes and papaya. In the case of fish bones there is a need for further kinetic studies using different fish species. The identification of pistachio nut shells is more complicated and further research is needed prior to the organization of a further intercomparison. Laboratories were able to distinguish between chicken bones irradiated in the range 1 to 3 KGy or 7 to 10 KGy although there was a partial overlap between the results from different laboratories.

  1. Electron spin resonance intercomparison studies on irradiated foodstuffs

    International Nuclear Information System (INIS)

    Raffi, J.

    1992-01-01

    The results of intercomparison studies organized by the Community Bureau of Reference on the use of electron spin resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. A quantitative intercomparison involving the use of poultry bones was also organized. There was no difficulty in identifying meat bones, dried grapes and papaya. In the case of fish bones there is a need for further kinetic studies using different fish species. The identification of pistachio nut shells is more complicated and further research is needed prior to the organization of a further intercomparison. Laboratories were able to distinguish between chicken bones irradiated in the range 1 to 3 KGy or 7 to 10 KGy although there was a partial overlap between the results from different laboratories

  2. The summertime ABL structure over an antarctic oasis with a vertical Doppler sodar

    Energy Technology Data Exchange (ETDEWEB)

    Kouznetsov, Rostislav D. [Obukhov Inst. of Atmospheric Physics, Moscow (Russian Federation)

    2009-04-15

    The one-component version of the multiple-frequency LATAN-3M sodar was operated during the summer 2006-2007 at the Russian Antarctic station Novolazarevskaya at Schirmacher oasis. We show the typical echograms for the prevailing conditions of forced turbulence, convective turbulence, strong katabatic flows and moist air advection with wave structures. The profiles of the vertical wind component and its variance reveal the vertical structure of local diurnal katabatic winds. We observed the core of a drainage flow at a height of 10-30 m. During the sea air mass advection, the wavy structures are clearly seen in the echograms at heights of 100-200 m a.g.l. The vertical wind component time series show that these waves are propagating rather than advected. The spectrum of the waves has a pronounced peak corresponding to the Brunt-Vaeisaelaefrequency in the layer 400-1000 m a.g.l. but not to that in the layer where the waves appear. (orig.)

  3. 1982 radon intercomparison exercises at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1983-03-01

    This report summarizes the results of two radon measurement intercomparison exercises held in 1982. Sixteen organizations, including five United States federal departments, two state governments, two national laboratories, three universities, three private sector laboratories and Swedish National Institute participated in these exercises. The results indicate good agreement among the participants at the 30 pCi 222 Rn/L level. With the continued interest and cooperation of groups involved in radon measurements, twp intercomparison exercises are planned during 1983

  4. The intercomparison of 137Cs irradiator output measurement and personal dose equivalent, Hp(10), using TLD and film

    International Nuclear Information System (INIS)

    Nazaroh; Susetyo Trijoko; Sri Inang Sunaryati

    2010-01-01

    Intercomparison of output measurement of 137 Cs irradiator and personal dose equivalent, Hp(10) using TLD and film have been carried out in the year of 2006 to 2008. According to IAEA recommendation, intercomparison is one of audit activities but it is performed in the spirit of collaboration and support rather than in the spirit of inspection. The aim of intercomparison of output measurement of 137 Cs irradiator is to verify the dose stated by the participant laboratories. Intercomparison is also to assess the competency of the participant, to keep traceability and consistency of measurement result, to assure that instrument work correctly and the result of evaluation was in agreement, and also for fulfilling one of the clauses of ISO-17025-2005. Besides that, this intercomparison aimed to facilitate link between the system and members of national measurement and transfer of experience in measurement technique and dose evaluation of radiation. The benefit of intercomparison is important among others as tests of proficiency in dose evaluation or measurement, upgrading quality of service and for obeying supervisor body legislation (BAPETEN). TLD was used as a means of output 137 Cs irradiator measurement, whereas film and TLD were used for dose intercomparison. This paper presented result of intercomparison of output measurement and evaluation of personal dose equivalent, Hp(10) in the year of 2006 to 2008 followed by 6 participants: Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Medan, Surabaya, Makasar, PTLR and Laboratory of Keselamatan dan Kesehatan Lingkungan (KKL)-PTKMR BATAN. In this intercomparison, the dose of TLD stated by participant were compared with the dose measured by Radiation Metrology Laboratory (LMR), and the results showed the differences were within 10 %, so it was satisfied. The results of intercomparison of personal dose equivalent, Hp(10) were evaluated based on ISO/IEC Guide 43-1, 1997 analysis and expressed as E n . The values of E n

  5. Comprehensive Australasian multicentre dosimetric intercomparison: issues, logistics and recommendations.

    Science.gov (United States)

    Ebert, M A; Harrison, K M; Cornes, D; Howlett, S J; Joseph, D J; Kron, T; Hamilton, C S; Denham, J W

    2009-02-01

    The present paper describes the logistics of the 2004-2008 Australasian Level III Dosimetry Intercomparison. Dosimetric intercomparisons (or 'audits') can be used in radiotherapy to evaluate the accuracy and quality of radiation delivery. An intercomparison was undertaken in New Zealand and Australia to evaluate the feasibility and logistics of ongoing dosimetric intercomparisons that evaluate all steps in the radiotherapy treatment process, known as a 'Level III' intercomparison. The study commenced in 2002 with the establishment of a study team, definition of the study protocol, acquisition of appropriate equipment and recruitment of participating radiotherapy centres. Measurements were undertaken between October 2004 and March 2008, and included collation of data on time, costs and logistics of the study. Forty independent Australian and New Zealand radiotherapy centres agreed to participate. Measurement visits were made to 37 of these centres. Data is presented on the costs of the study and the level of support required. The study involved the participation of 16 staff at the study centre who invested over 4000 hours in the study, and of over 200 professionals at participating centres. Recommendations are provided for future phantom-based intercomparisons. It is hoped that the present paper will be of benefit to any centres or groups contemplating similar activities by identifying the processes involved in establishing the study, the potential hazards and pitfalls, and expected resource requirements.

  6. Intercomparison of low-level tritium in water

    International Nuclear Information System (INIS)

    Sipka, V.; Zupancic, M.; Hadzisehovic, M.; Bacic, S.; Vukovic, Z.

    1989-01-01

    In 1985 the Section of Isotope Hydrology of the IAEA organized the fourth intercomparison for low-level tritium counting in waters. Four water samples with different 3 H concentration were sent to 85 laboratories willing to participate. The results from the different laboratories were presented in the unified questionnaires and coded. The participation in the intercomparisons for every laboratory doing low-level 3 H measurements in the waters is very important and useful. This is a best way to check the entire procedure and methods of the measurements and the reliability of the standards used. Since our laboratories are doing the natural 3 H concentration measurement in the waters for the environmental control and hydrology reasons it was necessary to take part in this intercomparison. Our standard procedure was applied. The 3 H activity in the samples was measured by liquid scintillation counting after an electrolytic enrichment. The results of our measurements of the four water samples, received from the organizers, are presented on the figures and tables presenting summary of the intercomparison. It is clear that our measurement (procedure and standards) have given satisfactory results (author)

  7. Environmental radioactivity intercomparison measurements

    International Nuclear Information System (INIS)

    2000-01-01

    In the context of the North Cotentin radioecological group set up in 1997 by the Ministry of the Environment and the Ministry of the Secretariat d'Etat a la Sante, the Swiss Federal Office of Public health, a national organization of independent status with respect to nuclear energy, conducted a series of measurements in the north Cotentin in 1998. Some sites proposed by local association 'Angry mothers' were examined in particular. This association has now taken the initiative to organize a large scale international intercomparison, ' North Cotentin 2000', in the vicinity of local nuclear installations. Besides the scientific aspect of the intercomparison, a specific aim of this intercomparison consists in providing to the local population with a real opportunity for direct exchange with participating international teams. The primary concern of the workshop is the determination, by in situ gamma spectrometry, of both natural and artificial concentrations and resulting ambient dose rates at selected marine ( beach) and terrestrial sites. A particular aim of the workshop also is to test the capacity of mobile teams to produce reliable results in the field of low level measurements on trace of special radionuclides (I 129 , Sr 90 , H 3 , C 14 , and alpha emitters) from environmental samples, using both direct ( in situ) and differed ( laboratory methods). an overview of the results obtained will be prepared for the benefit of the public. (N.C.)

  8. Eurados self-sustained programme of intercomparisons for individual monitoring services

    International Nuclear Information System (INIS)

    Grimbergen, T. W. M.; Figel, M.; Romero, A. M.; Stadtmann, H.; McWhan, A. F.

    2011-01-01

    Within EURADOS working group 2, a system for self-sustained intercomparisons for individual monitoring services for external radiation was developed. With the intercomparison results, the participants can show compliance within their quality management system, compare their results with those from other participants and develop plans for improvement of their system. The costs of the exercises are covered by the participants fees. In this programme, the first intercomparison exercise for whole-body dosemeters has been executed in 2008 with 62 participating dosimetry systems from participants across Europe. In general, film systems show the largest deviations, although the results of some participants indicate that it is possible to achieve results with a film system with similar quality as for thermoluminescence dosimetry (TLD) systems. A second intercomparison has been organised for extremity dosemeters in 2009. For 2010 it is planned to organise a second intercomparison for whole-body dosemeters. (authors)

  9. Intercomparison of PIXE spectrometry software packages

    International Nuclear Information System (INIS)

    2003-02-01

    During the year 2000, an exercise was organized to make a intercomparison of widely available software packages for analysis of particle induced X ray emission (PIXE) spectra. This TECDOC describes the method used in this intercomparison exercise and presents the results obtained. It also gives a general overview of the participating software packages. This includes basic information on their user interface, graphical presentation capabilities, physical phenomena taken in account, way of presenting results, etc. No recommendation for a particular software package or method for spectrum analysis is given. It is intended that the readers reach their own conclusions and make their own choices, according to their specific needs. This TECDOC will be useful to anyone involved in PIXE spectrum analysis. This TECDOC includes a companion CD with the complete set of test spectra used for intercomparison. The test spectra on this CD can be used to test any PIXE spectral analysis software package

  10. Intercomparison of radon gas detectors 1999 and 2000 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck, Gernot

    2000-10-01

    This report describes the results of two radon intercomparison exercises performed by the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut from Sep 9th to Oct 6th, 1999, and from March 21st to 28th, 2000. Radon gas detectors and instruments were exposed in the PSI Radon Chamber in reference atmospheres to 1060 kBqhm -3 radon gas exposure at an average radon gas concentration of 6400 Bqm -3 and to 2050 kBqhm -3 radon gas exposure at an average radon gas concentration of 12500 Bqm -3 , respectively. These intercomparison exercises determined the performance of electret ionisation chambers, track etch detectors and measuring instruments at high humidity (1999 Intercomparison Exercise) and at a high radon gas exposure (2000 Intercomparison Exercise). In the 1999 Intercomparison Exercise, electret ionisation chambers revealed an influence on high humidity. This effect may be due to impurities on a microscopic scale on the electrets of these detectors. With few exceptions, in both the 1999 and the 2000 Radon Intercomparison Exercise the deviations of the measurement results to the reference radon gas concentration values were less than 15% (traceability criterion) and the standard deviation of the results of five detectors less than 15% (reproducibility criterion). (author) [de

  11. Intercomparison of high energy neutron personnel dosimeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Akabani, G.; Loesch, R.M.

    1993-03-01

    An intercomparison of high-energy neutron personnel dosimeters was performed to evaluate the uniformity of the response characteristics of typical neutron dosimeters presently in use at US Department of Energy (DOE) accelerator facilities. It was necessary to perform an intercomparison because there are no national or international standards for high-energy neutron dosimetry. The testing that is presently under way for the Department of Energy Laboratory Accreditation Program (DOELAP) is limited to the use of neutron sources that range in energy from about 1 keV to 2 MeV. Therefore, the high-energy neutron dosimeters presently in use at DOE accelerator facilities are not being tested effectively. This intercomparison employed neutrons produced by the 9 Be(p,n) 9 B interaction at the University of Washington cyclotron, using 50-MeV protons. The resulting neutron energy spectrum extended to a maximum of approximately 50-MeV, with a mean energy of about 20-MeV. Intercomparison results for currently used dosimeters, including Nuclear Type A (NTA) film, thermoluminescent dosimeter (TLD)-albedo, and track-etch dosimeters (TEDs), indicated a wide variation in response to identical doses of high-energy neutrons. Results of this study will be discussed along with a description of plans for future work

  12. Biological dosimetry after criticality accidents. Intercomparison exercise in the Silene Reactor - France

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Vallerga, Maria B.; Taja, Maria R.

    2004-01-01

    The Institute of Radiation Protection and Nuclear Safety Institute (IRSN) organized an international biological dosimetry intercomparison, at the SILENE experimental reactor (Valduc, France), simulating different criticality scenarios: bare source 4 Gy, lead shield source 1 and 2 Gy and gamma pure 60 Co source 2 Gy. Fifteen laboratories were involved in this exercise, including the Argentine Biological Dosimetry Laboratory. The purposes of the intercomparison were: 1) To compare the unstable chromosome aberration (UCA) frequency observed by the different laboratories; and 2) To compare the dose estimation for gamma rays and neutrons. The objects of the present work were: I) To compare the mean frequency of UCA observed by the Argentine laboratory with the mean frequency observed by the participant laboratories as a whole. II) To compare the dose estimates performed by the Argentine lab with those estimated by the other laboratories involved in the second stage of the intercomparison. Overall, the mean frequencies of UCA and the correspondent 95% confidence limits obtained by the Argentine lab were consistent with the results obtained by the laboratories as a whole. For the gamma pure scenario, smaller variations were observed among laboratories in terms of dose (CV=18,2%) than in terms of frequency (CV=30,1%). For the mixed field scenarios, only four laboratories, including the Argentine lab, estimated gamma and neutron components of the total dose and just two (Argentine lab and lab 12) were in agreement with the given physical doses. The 1 Gy experiment presented lesser variations both in terms of frequency and dose than the other two scenarios. For the 4 and 2 Gy experiments, variations in neutron dose were more significant than variations in gamma dose, related to the magnitude of the dose. The results suggest that intercomparison exercises jointly with the accreditation of biological dosimetry by cytogenetic service laboratories, in compliance with ISO

  13. Identification of irradiated foodstuffs: results of a European test intercomparison

    International Nuclear Information System (INIS)

    Raffi, J.; Belliardo, J.-J.; Agnel, J.-P.; Vincent, P.

    1993-01-01

    The results of an intercomparison, organized by the Community Bureau of Reference (Commission of the European Communities), on the use of Electron Spin Resonance spectroscopy for the identification of irradiated food are presented. A qualitative intercomparison was carried out using beef and trout bones, sardine scales, pistachio nut shells, dried grapes and papaya. Protocols are proposed for meat bones, fish bones (with some restrictions) and fruits such as dried grapes and papaya. The protocol for pistachio nuts and fruits such as strawberries is more complicated and further research is needed prior the organization of future intercomparisons. A quantitative intercomparison on poultry bones was also organized. Laboratories were able to distinguish between chicken bones irradiated at 1 to 3 kGy or 7 to 10 kGy. (author)

  14. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  15. Neutron dosimetry intercomparison run for verification of the neutron fluence

    International Nuclear Information System (INIS)

    Penev, I.; Kinova, L.

    2001-01-01

    For the neutron fluence verification the intercomparison runs Balakovo and KORPUS have been carried out. The participation in the international intercomparison runs shows that in order to more precisely verify the calculated values of the neutron fluence more intercomparison exercises are necessary. Due to such exercises the results improved after calibration of Nb performed and are in a very good agreement with RIIAR results in spite of the different approaches in the determination of its activity

  16. Intercomparison of Rn-222 determination from groundwater

    DEFF Research Database (Denmark)

    Vesterbacka, P.; Pettersson, H.; Hanste, U.-M.

    2010-01-01

    An intercomparison exercise on Rn-222 determination in groundwater was organized between eight Nordic laboratories. The individual laboratory results were in most cases within 20% of the median value and within reported uncertainties. Considering the particular difficulties in preparing, transpor......An intercomparison exercise on Rn-222 determination in groundwater was organized between eight Nordic laboratories. The individual laboratory results were in most cases within 20% of the median value and within reported uncertainties. Considering the particular difficulties in preparing...

  17. Dosimetry intercomparisons in European medical device sterilization plants

    DEFF Research Database (Denmark)

    Miller, A.; Sharpe, P.H.G.

    2000-01-01

    Dosimetry intercomparisons have been carried out involving two-thirds of all European radiation sterilization facilities. Dosimeters for the intercomparisons were supplied by two accredited calibration laboratories. The results show good agreement, and indicate overall dosimetry accuracy of the o...... of the order of +/-5% (1 sigma) for both Co-60 and electron beam plants. (C) 2000 Elsevier Science Ltd. All rights reserved....

  18. Intercomparison program of personal dosemeters in the Argentine Republic

    International Nuclear Information System (INIS)

    Gregori, B.N.; Papadopulos, S.B.; Kunst, J.J.

    1998-01-01

    During 1997, under the auspices of the Nuclear Regulatory Authority (ARN), its was held the third exercise of intercomparison of laboratories of personal dosimetry. The dosemeters were irradiated in X-ray beams ISO quality W60, W110, W200 and gamma sources cesium 137 and cobalt 60. The irradiation were performed kerma free in air and in phantom in order to study the capacity to evaluate both conditions. An extent range of doses (low-high) have been given 0.3 mSv- 20mSv in order to determine the operative performance o each laboratory. Over 19 laboratories of Argentina, participated 13 (65%) and finished the intercomparison 12 (60%) of them. The systems of dosimetry detection were based on film and TLD. During this intercomparison as inquiry about several items related with the laboratories have been made. In this work are shown the individual laboratory results of the intercomparison related with the acceptance curve criteria ICRP 60 and 55. (author)

  19. Dosimetry intercomparisons between fast neutron radiotherapy facilities

    International Nuclear Information System (INIS)

    Almond, P.R.; Smith, A.R.; Smathers, J.B.; Otte, V.A.

    1975-01-01

    Neutron dosimetry intercomparisons have been made between M.D. Anderson Hospital and Tumor Institute, Naval Research Laboratory, University of Washington Hospital, and Hammersmith Hospital. The parameters that are measured during these visits are: tissue kerma in air, tissue dose at depth of dose maximum, depth dose, beam profiles, neutron/gamma ratios and photon calibrations of ionization chambers. A preliminary report of these intercomparisons will be given including a comparison of the calculation and statement of tumor doses for each institution

  20. IAEA intercomparisons in the frame of the occupational radiation protection programme

    International Nuclear Information System (INIS)

    Mrabit, K.; Cruz Suarez, R.

    2005-01-01

    The IAEA safety activities to support the assessment of occupational exposure through a comprehensive set of safety guides, safety reports and other related documents will soon be completed. Several intercomparison exercises were organized by the IAEA on the determination of radionuclides in human urine samples, whole body counting and external dosimetry. These previous intercomparison exercises revealed significant differences in the approaches, methods and assumptions, and consequently in the results. This underlined the importance of this kind of intercomparison programme as a key element of the international harmonization of quantities and units. The purpose of this paper is to present the current and future IAEA activities in support of assessment of occupational exposure by organizing intercomparison runs

  1. Thorium in the workplace measurement intercomparison

    International Nuclear Information System (INIS)

    Modna, D.K.; Jerome, S.M.; White, M.A.; Woods, M.J.

    2000-01-01

    The monitoring of radionuclides in the nuclear industry has been recognized as the most straightforward way of assessing health and safety issues associated with the exposure of the workforce to potentially harmful radiation doses. Much of this is achieved by measurements in the workplace itself and by the bioassay and monitoring of workers in the industry. However, there also exists a significant 'non-nuclear' industry where workers are exposed to radioactive materials, for example where this involves thorium, which is made wide use of in the aerospace and other high technology industries. As such work involves the processing of thorium bearing materials, the workforce is potentially exposed to 232 Th and its daughter nuclides. Thus, to monitor the workforce effectively, it is important to be able to measure both 232 Th and the decay products of 232 Th where they are in an unknown state of radioactive equilibrium and this is where monitoring laboratories may experience some difficulty. Accordingly, the Health and Safety Laboratory in the UK has organized a EC wide project on the monitoring of thorium in the 'non-nuclear' workplace; this project is currently ongoing. We report the results of the first intercomparison of this project involving two solutions of 232 Th, one in radioactive equilibrium and one not in equilibrium with its daughters. The results are presented with some comments on how this intercomparison has progressed and how these first results will inform the rest of the project

  2. Further AMBER and Ecolego Intercomparisons

    International Nuclear Information System (INIS)

    Maul, Philip; Robinson, Peter; Broed, Robert

    2004-01-01

    The AMBER compartmental modelling software is used by Quintessa in undertaking Performance Assessment (PA) calculations for SKI. SSI and NRPA are supporting the development of Ecolego which is based on the Matlab/Simulink general purpose modelling software for undertaking PA calculations. Intercomparison calculations using AMBER and Ecolego have been undertaken based on calculation cases considered in SKB's SR97 assessment. The reasons for undertaking such intercomparisons included: 1. to give confidence in the use of AMBER and Ecolego for whole system PA calculations for a deep repository; and 2. to provide SKI and SSI with an understanding of some of the technical issues raised by seeking to repeat the SR97 calculations with different models and software. Conclusions drawn from these intercomparisons included: 1. Both modelling packages successfully reproduced SKB's SR97 calculations for the near field, geosphere and biosphere. 2. AMBER and Ecolego calculations were typically in agreement to within one significant figure, but in several instances the SR97 documentation was not sufficiently clear to enable the implementation of the models in AMBER and Ecolego to be unambiguous. In order to gain more information on the comparisons between the two codes, additional intercomparisons have been undertaken using input data from the Vault Safety Case originally undertaken as part of an IAEA research project (ISAM). The comparisons between the AMBER and Ecolego calculations for the ISAM vault safety case have shown excellent agreement. Calculations at specified times generally agree to around three significant figures, and calculations of peak radionuclide fluxes and concentrations agree to two significant figures. This agreement is particularly good given the large number of model compartments and the inclusion of decay changes of up to six members. The most important situation where agreement may not be as good as that generally found is where radionuclides have been

  3. Intercomparisons for integrating the radon-thoron detector of NIRP, China with NIRS, Japan

    International Nuclear Information System (INIS)

    Wu, Yunyun; Cui, Hongxing; Zhang, Qingzhao; Shang, Bing

    2015-01-01

    Intercomparisons play an important role in maintaining a reasonable and accurate standard of measurement and quality. Integrating the radon-thoron detector of the National Institute for Radiological Protection (NIRP), China has continuously been a subject of four rounds of international intercomparisons organised by the National Institute of Radiological Sciences (NIRS), Japan during 2007-12. The intercomparisons were held at NIRS. The exercises included different exposures for both radon and thoron. The results of the intercomparison for the detectors of NIRP for both radon and thoron exposures were in the range of ±20 % from the reference value and were categorised as 'Category I' in the intercomparison carried out in 2011. The radon and thoron results of the LD-P detector in four rounds of intercomparison exercises were summarised, and uncertainties of all the radon and thoron results of NIRP were within the acceptable range of 30 % in environment. Radon and thoron measurement results between NIRP and NIRS were basically in agreement. (authors)

  4. Reproducibility in cyclostratigraphy: initiating an intercomparison project

    Science.gov (United States)

    Sinnesael, Matthias; De Vleeschouwer, David; Zeeden, Christian; Claeys, Philippe

    2017-04-01

    The study of astronomical climate forcing and the application of cyclostratigraphy have experienced a spectacular growth over the last decades. In the field of cyclostratigraphy a broad range in methodological approaches exist. However, comparative study between the different approaches is lacking. Different cases demand different approaches, but with the growing importance of the field, questions arise about reproducibility, uncertainties and standardization of results. The radioisotopic dating community, in particular, has done far-reaching efforts to improve reproducibility and intercomparison of radioisotopic dates and their errors. To satisfy this need in cyclostratigraphy, we initiate a comparable framework for the community. The aims are to investigate and quantify reproducibility of, and uncertainties related to cyclostratigraphic studies and to provide a platform to discuss the merits and pitfalls of different methodologies, and their applicabilities. With this poster, we ask the feedback from the community on how to design this comparative framework in a useful, meaningful and productive manner. In parallel, we would like to discuss how reproducibility should be tested and what uncertainties should stand for in cyclostratigraphy. On the other hand, we intend to trigger interest for a cyclostratigraphic intercomparison project. This intercomparison project would imply the analysis of artificial and genuine geological records by individual researchers. All participants would be free to determine their method of choice. However, a handful of criterions will be required for an outcome to be comparable. The different results would be compared (e.g. during a workshop or a special session), and the lessons learned from the comparison could potentially be reported in a review paper. The aim of an intercomparison project is not to rank the different methods according to their merits, but to get insight into which specific methods are most suitable for which

  5. Determination of total and methylmercury compounds in the IAEA human hair intercomparison samples - Experience of the IAEA-MEL

    International Nuclear Information System (INIS)

    Horvat, M.; Liang, L.; Mandic, V.

    1995-01-01

    The programme of this CRP is focused on the analyses of human hair samples. There are only two human hair samples certified for total mercury, and no RMs for methylmercury compounds is available. One of the main objectives of this CRP is to produce, through the IAEA AQCS Programme, a human hair intercomparison material for quality assurance requirements in population monitoring programmes for total and methylmercury exposure. Through the reporting period, MESL has introduced a new method for simultaneous determination of total and methylmercury in biological samples. As the laboratory has close collaboration with the CRP's Reference Laboratory in Ljubljana, Slovenia, it has also been actively involved in the quality assurance component of this CRP. This report represents a summary on the results for total and methylmercury in two intercomparison samples, IAEA-085 and IAEA-086 using newly developed method

  6. Lessons learnt from an international intercomparison of national network systems used to provide early warning of a nuclear accident

    DEFF Research Database (Denmark)

    Saez-Vergara, J.C.; Thompson, I.M.G.; Funck, E.

    2003-01-01

    and at the Underground Laboratory for Dosimetry and Spectrometry (UDO) of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The network systems are used continuously to monitor radiation levels throughout a country in order to give early warning of nuclear accidents having transboundary implications...... in order to be consistent with the preliminary report. In addition, in some cases the results are also given in terms of the quantity measured by each national network system. The experience gained from this intercomparison is used to help organise a follow-up intercomparison to be held at the PTB...

  7. Reference values and evaluation of the results of intercomparisons

    International Nuclear Information System (INIS)

    Aigner, H.; Deron, S.; Kuhn, E.

    1981-01-01

    The need of a reference value for the composition of materials distributed in intercomparisons is generally recognized. A single reference laboratory or a group of reference laboratories may be used to establish this reference value. The respective advantages and limitations of the two approaches are discussed. The reference measurements must be evaluated to provide the confidence limits of the reference value but also an estimate of the possible heterogeneity of the materials and its samples. The results of the intercomparison measurements should themselves be evaluated to test and discuss the significance of the biases of individual and selected groups of laboratories or techniques. The approach taken by the Analytical Quality Control Services of the International Atomic Energy Agency is illustrated by the SR-1 intercomparison on uranium assay in UO 2 powder

  8. Airborne hygrometer calibration inter-comparison against a metrological water vapour standard

    Science.gov (United States)

    Smorgon, Denis; Boese, Norbert; Ebert, Volker

    2014-05-01

    Water vapour is the most important atmospheric greenhouse gas, which causes a major feedback to warming and other changes in the climate system. Knowledge of the distribution of water vapour and its climate induced changes is especially important in the upper troposphere and lower stratosphere (UT/LS) where vapour plays a critical role in atmospheric radiative balance, cirrus cloud formation, and photochemistry. But, our understanding of water in the UT/LS is limited by significant uncertainties in current UT/LS water measurements. One of the most comprehensive inter-comparison campaigns for airborne hygrometers, termed AQUAVIT (AV1) [1], took place in 2007 at the AIDA chamber at the Karlsruhe Institute of Technology (KIT) in Germany. AV1 was a well-defined, referred, blind inter-comparison of 22 airborne field instruments from 17 international research groups. One major metrological deficit of AV1, however, was, that no traceable reference instrument participated in the inter-comparison experiments and that the calibration procedures of the participating instruments were not monitored or interrogated. Consequently a follow-up inter-comparison was organized in April 2013, which for the first time also provides a traceable link to the international humidity scale. This AQUAVIT2 (AV2) campaign (details see: http://www.imk-aaf.kit.edu/aquavit/index.php/Main_Page) was again located at KIT/AIDA and organised by an international organizing committee including KIT, PTB, FZJ and others. Generally AV2 is divided in two parallel comparisons: 1) AV2-A uses the AIDA chamber for a simultaneous comparison of all instruments (incl. sampling and in-situ instruments) over a broad range of conditions characteristic for the UT/LS; 2) AV2-B, about which this paper is reporting, is a sequential comparison of selected hygrometers and (when possible) their reference calibration infrastructures by means of a chilled mirror hygrometer traced back to the primary National humidity standard

  9. Results of the dosimetry intercomparison

    International Nuclear Information System (INIS)

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  10. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    International Nuclear Information System (INIS)

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs

  11. Intercomparison of active personal dosemeters in interventional radiology

    International Nuclear Information System (INIS)

    Clairand, I.; Struelens, L.; Bordy, J. M.; Daures, J.; Debroas, J.; Denozieres, M.; Donadille, L.; Gouriou, J.; Itie, C.; Vaz, P.; D'Errico, F.

    2008-01-01

    The use of active personal dosemeters (APD) in interventional radiology was evaluated by Working Group 9 (Radiation protection dosimetry of medical staff) of the CONRAD project, which is a Coordination Action supported by the European Commission within its sixth Framework Programme. Interventional radiology procedures can be very complex and they can lead to relatively high doses to personnel who stand close to the primary radiation field and are mostly exposed to radiation scattered by the patient. For the adequate dosimetry of the scattered photons, APDs must be able to respond to low-energy [10-100 keV] and pulsed radiation with relatively high instantaneous dose rates. An intercomparison of five APD models deemed suitable for application in interventional radiology was organised in March 2007. The intercomparison used pulsed and continuous radiation beams, at CEA-LIST (Saclay (France)) and IRSN (Fontenay-aux-Roses (France)), respectively. A specific configuration, close to the clinical practice, was considered. The reference dose, in terms of Hp(10), was derived from air kerma measurements and from the measured and calculated energy distributions of the scattered radiation field. Additional Monte Carlo calculations were performed to investigate the energy spectra for different experimental conditions of the intercomparison. The results of this intercomparison are presented in this work and indicate which APDs are able to provide a correct response when used in the specific low-energy spectra and dose rates of pulsed X-rays encountered in interventional radiology. (authors)

  12. EURADOS intercomparison 2006 to harmonise European early warning dosimetry systems

    International Nuclear Information System (INIS)

    Dombrowski, H.; Neumaier, S.; Thompson, I. M. G.; Wissmann, F.

    2009-01-01

    In 2006, the European Radiation Dosimetry (EURADOS) Working Group on Environmental Radiation Monitoring (WG3) organised a third European intercomparison of dosimetry systems operated in national early warning networks. Similar to the intercomparisons in 1999 and 2002, the main aim of this exercise was to support the process of harmonisation of area monitoring in Europe by providing the network operators with basic information on the calibration and performance of their dosimetry systems. In order to characterise these systems, their following basic parameters were investigated: the response to terrestrial and cosmic radiation, the detectors' inherent background, the response at low dose rates, the energy dependence of the response as well as the sensitivity of the detector systems to small changes of the dose rate in a natural environmental radiation field. In the 2006 EURADOS intercomparison, scientists from seven countries participated to study the characteristics of 11 detector systems. All results are presented in terms of the operational quantity ambient dose equivalent, H * (10). The advent of this quantity has caused the development of new detector systems for area monitoring. Some of these new systems participated in a EURADOS intercomparison for the first time. The results are consistently presented together with uncertainties so that statistical effects can be distinguished from real detector features, which improves the interpretation of the results. By using the results of this intercomparison, some detectors were re-calibrated. The achievable improvements concerning harmonisation in dose-rate measurements in the natural environment are discussed. (authors)

  13. Intercomparison of transuranics in sediments

    International Nuclear Information System (INIS)

    Nilsson, K.

    1981-01-01

    This paper summarizes the results of a recent intercomparison of transuranic analyses in Nordic sediments undertaken by five laboratories. Five different samplers were tested to determine their consistency and utility. Plutonium and americium were determined in all the samples and the analysis of variance is discussed. (author)

  14. An intercomparison experiment on isotope dilution thermal ionisation mass spectrometry using plutonium-239 spike for the determination of plutonium concentration in dissolver solution of irradiated fuel

    International Nuclear Information System (INIS)

    Aggarwal, S.K.; Shah, P.M.; Saxena, M.K.; Jain, H.C.; Gurba, P.B.; Babbar, R.K.; Udagatti, S.V.; Moorthy, A.D.; Singh, R.K.; Bajpai, D.D.

    1996-01-01

    Determination of plutonium concentration in the dissolver solution of irradiated fuel is one of the key measurements in the nuclear fuel cycle. This report presents the results of an intercomparison experiment performed between Fuel Chemistry Division (FCD) at BARC and PREFRE, Tarapur for determining plutonium concentration in dissolver solution of irradiated fuel using 239 Pu spike in isotope dilution thermal ionisation mass spectrometry (ID-TIMS). The 239 Pu spike method was previously established at FCD as viable alternative to the imported enriched 242 Pu or 244 Pu; the spike used internationally for plutonium concentration determination by IDMS in dissolver solution of irradiated fuel. Precision and accuracy achievable for determining plutonium concentration are compared under the laboratory and the plant conditions using 239 Pu spike in IDMS. For this purpose, two different dissolver solutions with 240 Pu/ 239 Pu atom ratios of about 0.3 and 0.07 corresponding, respectively, to high and low burn-up fuels, were used. The results of the intercomparison experiment demonstrate that there is no difference in the precision values obtained under the laboratory and the plant conditions; with mean precision values of better than 0.2%. Further, the plutonium concentration values determined by the two laboratories agreed within 0.3%. This exercise, therefore, demonstrates that ID-TIMS method using 239 Pu spike can be used for determining plutonium concentration in dissolver solution of irradiated fuel, under the plant conditions. 7 refs., 8 tabs

  15. Second Latin American intercomparison on internal dose assessment

    International Nuclear Information System (INIS)

    Rojo, A.; Puerta, N.; Gossio, S.; Gomez Parada, I.; Cruz Suarez, R.; Lopez, E.; Medina, C.; Lastra Boylan, J.; Pinheiro Ramos, M.; Mora Ramirez, E.; Alves dos Reis, A.; Yanez, H.; Rubio, J.; Vironneau Janicek, L.; Somarriba Vanegas, F.; Puerta Ortiz, J.; Salas Ramirez, M.; Lopez Bejerano, G.; Da Silva, T.; Miri Oliveira, C.; Teran, M.; Alfaro, M.; Garcia, T.; Angeles, A.; Dure Romero, E.; Farias de Lima, F.

    2016-01-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of 131 I, 137 Cs and Tritium were proposed. Nineteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. (authors)

  16. RCA/IAEA third external dosimetry intercomparison in East Asia

    International Nuclear Information System (INIS)

    Momose, T.; Yamamoto, H.; Cruz Suarez, R.

    2005-01-01

    Full text: Several intercomparison exercises were organized by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or interregional basis. These exercises revealed significant differences in the approach, methods and assumptions, and consequently in the measurement results obtained by participating laboratories. In the East Asia region, the third phase of the Hp(10) intercomparison, organized within the frame of the Regional Cooperation Agreement (RCA) as a follow-up to previous exercises during 1990-92 and 1995-96, was completed mid-2004. The first phase grouped 25 laboratories from 16 member states, and 4 Secondary Standards Dosimetry Laboratories irradiated dosimeters in 6 different qualities for photon and beta radiations. In the second phase, 23 laboratories from 16 member states participated, and 3 Secondary Standards Dosimetry Laboratories provided irradiation in 5 different radiation qualities simulating workplace fields. The results of the second phase for the determination of operational quantities Hp(d) were satisfactory for all participating Member States, with marked improvement from the first phase; the laboratories demonstrated good performance in both quantities tested. These results underline the importance of such an intercomparison programme as a key element towards the harmonization of quantities and units on an international level. This paper presents the results of this RCA/IAEA intercomparison, and also the forthcoming RCA activities supporting intercomparison runs for the assessment of occupational exposure. Member states strongly recommend that the IAEA continue acting as a focal point for, inter alia, training in all forms, particularly in measurements and dosimetry techniques. This exercise also stressed the importance for the IAEA to take an active role in establishing a network of monitoring laboratories for radiation protection purposes, as it would provide for better information

  17. GMMIP (v1.0) contribution to CMIP6: Global Monsoons Model Inter-comparison Project

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tianjun; Turner, Andrew G.; Kinter, James L.; Wang, Bin; Qian, Yun; Chen, Xiaolong; Wu, Bo; Wang, Bin; Liu, Bo; Zou, Liwei; He, Bian

    2016-10-10

    The Global Monsoons Model Inter-comparison Project (GMMIP) has been endorsed by the panel of Coupled Model Inter-comparison Project (CMIP) as one of the participating model inter-comparison projects (MIPs) in the sixth phase of CMIP (CMIP6). The focus of GMMIP is on monsoon climatology, variability, prediction and projection, which is relevant to four of the “Grand Challenges” proposed by the World Climate Research Programme. At present, 21 international modeling groups are committed to joining GMMIP. This overview paper introduces the motivation behind GMMIP and the scientific questions it intends to answer. Three tiers of experiments, of decreasing priority, are designed to examine (a) model skill in simulating the climatology and interannual-to-multidecadal variability of global monsoons forced by the sea surface temperature during historical climate period; (b) the roles of the Interdecadal Pacific Oscillation and Atlantic Multidecadal Oscillation in driving variations of the global and regional monsoons; and (c) the effects of large orographic terrain on the establishment of the monsoons. The outputs of the CMIP6 Diagnostic, Evaluation and Characterization of Klima experiments (DECK), “historical” simulation and endorsed MIPs will also be used in the diagnostic analysis of GMMIP to give a comprehensive understanding of the roles played by different external forcings, potential improvements in the simulation of monsoon rainfall at high resolution and reproducibility at decadal timescales. The implementation of GMMIP will improve our understanding of the fundamental physics of changes in the global and regional monsoons over the past 140 years and ultimately benefit monsoons prediction and projection in the current century.

  18. A Methodological Inter-Comparison of Gridded Meteorological Products

    Science.gov (United States)

    Newman, A. J.; Clark, M. P.; Longman, R. J.; Giambelluca, T. W.; Arnold, J.

    2017-12-01

    Here we present a gridded meteorology inter-comparison using the state of Hawaíi as a testbed. This inter-comparison is motivated by two general goals: 1) the broad user community of gridded observation based meteorological fields should be aware of inter-product differences and the reasons they exist, which allows users to make informed choices on product selection to best meet their specific application(s); 2) we want to demonstrate the utility of inter-comparisons to meet the first goal, yet highlight that they are limited to mostly generic statements regarding attribution of differences that limits our understanding of these complex algorithms and obscures future research directions. Hawaíi is a useful testbed because it is a meteorologically complex region with well-known spatial features that are tied to specific physical processes (e.g. the trade wind inversion). From a practical standpoint, there are now several monthly climatological and daily precipitation and temperature datasets available that are being used for impact modeling. General conclusions that have emerged are: 1) differences in input station data significantly influence product differences; 2) prediction of precipitation occurrence is crucial across multiple metrics; 3) derived temperature statistics (e.g. diurnal temperature range) may have large spatial differences across products; and 4) attribution of differences to methodological choices is difficult and may limit the outcomes of these inter-comparisons, particularly from a development viewpoint. Thus, we want to continue to move the community towards frameworks that allow for multiple options throughout the product generation chain and allow for more systematic testing.

  19. Report on the Intercomparison Exercises 1993

    DEFF Research Database (Denmark)

    Aminot, A.; Boer, J. de; Cofino, W.

    This report covers the intercomparison exercises - 1993 of the project Quasimeme - Quality Assurance of Information for Marine Environmental Monitoring in Europe. The report is prepared under contract for the measurement and testing programme (BCR) of the European Community....

  20. The role of intercomparisons and intercalibrations in the improvement of internal dose assessment

    International Nuclear Information System (INIS)

    Griffith, R.V.

    2000-01-01

    In vivo monitoring and dose assessment is a highly technical field. Moreover, it is carried out by a relatively small number of specialists. A number of technical steps can be taken to improve internal dosimetry programmes. However, one of the most valuable activities for overall improvement of measurement programmes is active participation in national and international intercomparisons and intercalibrations. These bring a number of benefits to the internal dosimetry programme, including validation of measurement practices, harmonisation of techniques, information exchange, and training. The number of intercalibration and intercomparison activities conducted on the national and international level has grown in recent years. These activities may involve actual measurement programmes or calculation exercises to compare approaches used for assessment of internal dose from measurement results. When conducted effectively such programmes are a highly cost effective use of limited resources. They also contribute to the credibility of the overall dosimetry process. Intercomparisons should be an important component of the in vivo measurement programme. Cooperation between the organisers of various intercomparison activities is essential to avoid unnecessary duplication and ensure the most effective use of the participants' time and energy. Future activities should address the use of simplified phantoms and source arrays to expedite shipping, reduce cost, and contribute to more timely conduct of intercomparisons. It is also important that managers and regulatory authorities be prepared to support intercomparison and intercalibration programmes. (author)

  1. Lessons learnt from an international intercomparison of national network systems used to provide early warning of a nuclear accident

    International Nuclear Information System (INIS)

    Saez-Vergara, J.C.; Thompson, I.M.G.; Funck, E.; Andersen, C.E.; Neumaier, S.; Botter-Jensen, L.

    2003-01-01

    As part of the European Research Council's Fourth Framework Programme, the EURADOS Action Group on Monitoring of External Exposures held an intercomparison of national network systems. This took place during May/June 1999 at the Riso Natural Environmental Radiation Measurement Station in Denmark and at the Underground Laboratory for Dosimetry and Spectrometry of the Physikalisch-Technische Bundesanstalt in Germany. The network systems are used continuously to monitor radiation levels throughout a country in order to give early warning of nuclear accidents having transboundary implications. The radiation levels measured are used to estimate the radiation risks to people arising from the accident. Seven European countries participated in the intercomparison with detector systems used in their national network systems as well as with detectors being developed for future use. Since different radiation quantities were measured by the systems (namely exposure, air kerma and ambient dose equivalent), the initial analysis of the intercomparison results was made in terms of the quantity air kerma rate. This report completes the analysis of the results and these are given in terms of air kerma rate in order to be consistent with the preliminary report. In addition, in some cases the results are also given in terms of the quantity measured by each national network system. The experience gained from this intercomparison is used to help organise a follow-up intercomparison to be held at the PTB Braunschweig in September 2002 and in which a further seven or eight countries from Europe will participate. (author)

  2. Model Intercomparison Study to Investigate a Dense Contaminant Plume in a Complex Hydrogeologic System

    International Nuclear Information System (INIS)

    Williams, Mark D.; Cole, Charles R.; Foley, Michael G.; Zinina, Galina A.; Zinin, Alexander I.; Vasil'Kova, Nelly A.; Samsonova, Lilia M.

    2001-01-01

    A joint Russian and U.S. model intercomparison study was undertaken for developing more realistic contaminant transport models of the Mayak Site, Southern Urals. The test problems were developed by the Russian Team based on their experience modeling contaminant migration near Lake Karachai. The intercomparison problems were designed to address lake and contaminant plume interactions, as well as river interactions and plume density effects. Different numerical codes were used. Overall there is good agreement between the results of both models. Features shown by both models include (1) the sinking of the plume below the lake, (2) the raising of the water table in the fresh water adjacent to the lake in response to the increased pressure from the dense plume, and (3) the formation of a second sinking plume in an area where evapotranspiration exceeded infiltration, thus increasing the solute concentrations above the source (i.e., lake) values

  3. Performance of dichromate dosimetry systems in calibration and dose intercomparison

    International Nuclear Information System (INIS)

    Bof, E.S.; Smolko, E.

    1999-01-01

    This report presents the results of the High Dose Dosimetry Laboratory of Argentina during ten years of international intercomparisons for high dose with the International Dose Assurance Service (IDAS) of the IAEA, using the standard high dose dichromate dosimetry system, and the results of a high dose intercomparison regional exercise in which our Laboratory acted as a reference laboratory, using the standard high dose and low dose dichromate dosimetry system. (author)

  4. Atmospheric Correction Inter-comparison Exercise (ACIX)

    Science.gov (United States)

    Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.

    2017-12-01

    The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison

  5. Report on the intercomparison run IAEA-384. Radionuclides in Fangataufa lagoon sediment

    International Nuclear Information System (INIS)

    Povinec, P.P.; Pham, M.K.

    2000-01-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, and to assist Member States in verifying the performance of their laboratories, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, in 1996 IAEA-MEL collected sediment in Fangataufa lagoon, French Polynesia. The sample aliquots were distributed during 1997-1998 for intercomparison of anthropogenic and natural radionuclides. 110 laboratories worldwide agreed to participate. Of these, only 94 sent results which could be used in the evaluation of this intercomparison exercise. This report describes the results obtained from 94 laboratories on anthropogenic and natural radionuclide determinations in Fangataufa lagoon sediment

  6. Report on the intercomparison run IAEA-384. Radionuclides in Fangataufa lagoon sediment

    Energy Technology Data Exchange (ETDEWEB)

    Povinec, P P; Pham, M K

    2000-07-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, and to assist Member States in verifying the performance of their laboratories, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, in 1996 IAEA-MEL collected sediment in Fangataufa lagoon, French Polynesia. The sample aliquots were distributed during 1997-1998 for intercomparison of anthropogenic and natural radionuclides. 110 laboratories worldwide agreed to participate. Of these, only 94 sent results which could be used in the evaluation of this intercomparison exercise. This report describes the results obtained from 94 laboratories on anthropogenic and natural radionuclide determinations in Fangataufa lagoon sediment.

  7. An intercomparison of a large ensemble of statistical downscaling methods for Europe: Overall results from the VALUE perfect predictor cross-validation experiment

    Science.gov (United States)

    Gutiérrez, Jose Manuel; Maraun, Douglas; Widmann, Martin; Huth, Radan; Hertig, Elke; Benestad, Rasmus; Roessler, Ole; Wibig, Joanna; Wilcke, Renate; Kotlarski, Sven

    2016-04-01

    VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. This framework is based on a user-focused validation tree, guiding the selection of relevant validation indices and performance measures for different aspects of the validation (marginal, temporal, spatial, multi-variable). Moreover, several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur (assessment of intrinsic performance, effect of errors inherited from the global models, effect of non-stationarity, etc.). The list of downscaling experiments includes 1) cross-validation with perfect predictors, 2) GCM predictors -aligned with EURO-CORDEX experiment- and 3) pseudo reality predictors (see Maraun et al. 2015, Earth's Future, 3, doi:10.1002/2014EF000259, for more details). The results of these experiments are gathered, validated and publicly distributed through the VALUE validation portal, allowing for a comprehensive community-open downscaling intercomparison study. In this contribution we describe the overall results from Experiment 1), consisting of a European wide 5-fold cross-validation (with consecutive 6-year periods from 1979 to 2008) using predictors from ERA-Interim to downscale precipitation and temperatures (minimum and maximum) over a set of 86 ECA&D stations representative of the main geographical and climatic regions in Europe. As a result of the open call for contribution to this experiment (closed in Dec. 2015), over 40 methods representative of the main approaches (MOS and Perfect Prognosis, PP) and techniques (linear scaling, quantile mapping, analogs, weather typing, linear and generalized regression, weather generators, etc.) were submitted, including information both data

  8. SECOND LATIN AMERICAN INTERCOMPARISON ON INTERNAL DOSE ASSESSMENT.

    Science.gov (United States)

    Rojo, A; Puerta, N; Gossio, S; Gómez Parada, I; Cruz Suarez, R; López, E; Medina, C; Lastra Boylan, J; Pinheiro Ramos, M; Mora Ramírez, E; Alves Dos Reis, A; Yánez, H; Rubio, J; Vironneau Janicek, L; Somarriba Vanegas, F; Puerta Ortiz, J; Salas Ramírez, M; López Bejerano, G; da Silva, T; Miri Oliveira, C; Terán, M; Alfaro, M; García, T; Angeles, A; Duré Romero, E; Farias de Lima, F

    2016-09-01

    Internal dosimetry intercomparisons are essential for the verification of applied models and the consistency of results'. To that aim, the First Regional Intercomparison was organised in 2005, and that results led to the Second Regional Intercomparison Exercise in 2013, which was organised in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear of Argentina. Four simulated cases covering intakes of (131)I, (137)Cs and Tritium were proposed. Ninteen centres from thirteen different countries participated in this exercise. This paper analyses the participants' results in this second exercise in order to test their skills and acquired knowledge, particularly in the application of the IDEAS Guidelines. It is important to highlight the increased number of countries that participated in this exercise compared with the first one and, furthermore, the improvement in the overall performance. The impact of the International Atomic Energy Agency (IAEA) Projects since 2003 has led to a significant enhancement of internal dosimetry capabilities that strengthen the radiation protection of workers. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Twenty-first nuclear accident dosimetry intercomparison study, August 6-10, 1984

    International Nuclear Information System (INIS)

    Swaja, R.E.; Ragan, G.E.; Sims, C.S.

    1985-05-01

    The twenty-first in a series of nuclear accident dosimetry (NAD) intercomparison (NAD) studies was conducted at the Oak Ridge National Laboratory's Dosimetry Applications Research Facility during August 6-10, 1984. The Health Physics Research Reactor operated in the pulse mode was used to simulate three criticality accidents with different radiation fields. Participants from five organizations measured neutron doses between 0.53 and 4.36 Gy and gamma doses between 0.19 and 1.01 Gy at area monitoring stations and on phantoms. About 75% of all neutron dose estimates based on foil activation, hair activation, simulated blood sodium activation, and thermoluminescent methods were within +-25% of reference values. Approximately 86% of all gamma results measured using thermoluminescent (TLD-700 or CaSO 4 ) systems were within +-20% of reference doses which represents a significant improvement over previous studies. Improvements observed in the ability of intercomparison participants to estimate neutron and gamma doses under criticality accident conditions can be partly attributed to experience in previous NAD studies which have provided practical tests of dosimetry systems, enabled participants to improve evaluation methods, and standardized dose reporting conventions. 16 refs., 15 tabs

  10. Environmental radioactive intercomparison program and radioactive standards program

    Energy Technology Data Exchange (ETDEWEB)

    Dilbeck, G. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    The Environmental Radioactivity Intercomparison Program described herein provides quality assurance support for laboratories involved in analyzing public drinking water under the Safe Drinking Water Act (SDWA) Regulations, and to the environmental radiation monitoring activities of various agencies. More than 300 federal and state nuclear facilities and private laboratories participate in some phase of the program. This presentation describes the Intercomparison Program studies and matrices involved, summarizes the precision and accuracy requirements of various radioactive analytes, and describes the traceability determinations involved with radioactive calibration standards distributed to the participants. A summary of program participants, sample and report distributions, and additional responsibilities of this program are discussed.

  11. Importance of Intercomparison Exercises in Assessment of Internal Exposure by Whole-Body Counter

    International Nuclear Information System (INIS)

    Andrasi, A.

    2001-01-01

    Full text: Basic requirement for any kind of measurement is to check and prove the reliability and correctness of the measured results. Quality assurance programmes require several activities among which the participation in intercomparison exercises plays an important role. Since the determination of radioactive materials in the human body by whole-body counting technique implies many sources of uncertainties the reliability of calibration data and consequently the measured results have to be checked by participation in intercomparison quality control programmes. In these programmes mostly different kinds of phantoms simulating the human body are circulated among the participating laboratories, however sometimes contaminated persons are also subjects of intercomparison measurements. There are guidelines in several countries laid down concerning the requirements of whole-body counter measurements where the performance criteria for the relative bias, precision and minimum detectable amounts are formulated. These quantities are mostly the subject of intercomparison programmes. The whole body counter laboratory of the KFKI Atomic Energy Research Institute participated in intercomparison exercises several times in the last few years. The lessons learned during these activities helped in checking the capabilities of applied methods and measuring geometry as well as contributed in improving the accuracy of the measured results. A short overview on the previous international intercomparison exercises their main characteristics the results obtained and conclusions drawn are discussed in the paper with special attention to those in which also our laboratory participated. (author)

  12. Intercomparison campaign of Contracted Partner Institutes 1997

    International Nuclear Information System (INIS)

    Reinen, H.A.J.M.; Tijsmans, M.H.; Van Tuinen, S.T.; Overwater, R.M.W.; Aldenkamp, F.J.

    1998-01-01

    The Dutch National Plan for Nuclear Emergency Planning and Response (EPR) is trained frequently. Intercomparison campaigns and exercises are part of this training for the Contracted Partner Institutes (CPI). The results of an intercomparison campaign in 1997 for the CPI are reported. Two carbon cartridges, one contaminated homogeneously and one inhomogeneously with 131 I, and a water sample contaminated with 134 Cs and 137 Cs were analysed by means of gamma spectroscopy. The results had to be faxed to RIVM within the time limits prescribed in the emergency protocols for CPI, i.e. 2 hours for the cartridges and 24 hours for the water sample. Most CPI reported in time. The results for the inhomogeneously contaminated cartridge are within 25% from the accepted reference value (ARV). For the homogeneously contaminated cartridge the results are within 40% from the ARV. In reality, the contamination of the cartridge will have an exponential profile, with most of the activity in the first few millimeters. In this situation results can be expected to be within 20% from the true value. The results for the water sample are within 5% from the ARV. Although most CPI have applied corrections for coincidence summing for 134 Cs there is still a systematic error of 4% for this nuclide. In regard of the requirements for measurements during emergency situations, the results of this intercomparison campaign are satisfactory

  13. Dosimetry audits and intercomparisons in radiotherapy: A Malaysian profile

    International Nuclear Information System (INIS)

    Noor, Noramaliza M.; Nisbet, A.; Hussein, M.; Chu S, Sarene; Kadni, T.; Abdullah, N.; Bradley, D.A.

    2017-01-01

    Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 µm core diameter Ge-doped silica fibres (Ge-9 µm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%. - Highlights: • We review significant factors that impact upon radiotherapy dosimetry, • We carried out the

  14. A soil sampling intercomparison exercise for the ALMERA network

    Energy Technology Data Exchange (ETDEWEB)

    Belli, Maria [Istituto Superiore per la Protezione e la Ricerca Ambientale (ISPRA), Via di Castel Romano 100, I-00128 Roma (Italy)], E-mail: maria.belli@apat.it; Zorzi, Paolo de [Istituto Superiore per la Protezione e la Ricerca Ambientale (ISPRA), Via di Castel Romano 100, I-00128 Roma (Italy)], E-mail: paolo.dezorzi@isprambiente.it; Sansone, Umberto [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: u.sansone@iaea.org; Shakhashiro, Abduhlghani [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.shakhashiro@iaea.org; Gondin da Fonseca, Adelaide [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.gondin-da-fonseca-azeredo@iaea.org; Trinkl, Alexander [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: a.trinkl@iaea.org; Benesch, Thomas [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-2444 Seibersdorf (Austria)], E-mail: t.benesch@iaea.org

    2009-11-15

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a 'reference site', aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  15. A soil sampling intercomparison exercise for the ALMERA network

    International Nuclear Information System (INIS)

    Belli, Maria; Zorzi, Paolo de; Sansone, Umberto; Shakhashiro, Abduhlghani; Gondin da Fonseca, Adelaide; Trinkl, Alexander; Benesch, Thomas

    2009-01-01

    Soil sampling and analysis for radionuclides after an accidental or routine release is a key factor for the dose calculation to members of the public, and for the establishment of possible countermeasures. The IAEA organized for selected laboratories of the ALMERA (Analytical Laboratories for the Measurement of Environmental Radioactivity) network a Soil Sampling Intercomparison Exercise (IAEA/SIE/01) with the objective of comparing soil sampling procedures used by different laboratories. The ALMERA network is a world-wide network of analytical laboratories located in IAEA member states capable of providing reliable and timely analysis of environmental samples in the event of an accidental or intentional release of radioactivity. Ten ALMERA laboratories were selected to participate in the sampling exercise. The soil sampling intercomparison exercise took place in November 2005 in an agricultural area qualified as a 'reference site', aimed at assessing the uncertainties associated with soil sampling in agricultural, semi-natural, urban and contaminated environments and suitable for performing sampling intercomparison. In this paper, the laboratories sampling performance were evaluated.

  16. PNNL Results from 2010 CALIBAN Criticality Accident Dosimeter Intercomparison Exercise

    International Nuclear Information System (INIS)

    Hill, Robin L.; Conrady, Matthew M.

    2011-01-01

    This document reports the results of the Hanford personnel nuclear accident dosimeter (PNAD) and fixed nuclear accident dosimeter (FNAD) during a criticality accident dosimeter intercomparison exercise at the CEA Valduc Center on September 20-23, 2010. Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimeter intercomparison exercise at the Commissariat a Energie Atomique (CEA) Valduc Center near Dijon, France on September 20-23, 2010. The intercomparison exercise was funded by the U.S. Department of Energy, Nuclear Criticality Safety Program, with Lawrence Livermore National Laboratory as the lead Laboratory. PNNL was one of six invited DOE Laboratory participants. The other participating Laboratories were: Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Savannah River Site (SRS), the Y-12 National Security Complex at Oak Ridge, and Sandia National Laboratory (SNL). The goals of PNNL's participation in the intercomparison exercise were to test and validate the procedures and algorithm currently used for the Hanford personnel nuclear accident dosimeters (PNADs) on the metallic reactor, CALIBAN, to test exposures to PNADs from the side and from behind a phantom, and to test PNADs that were taken from a historical batch of Hanford PNADs that had varying degrees of degradation of the bare indium foil. Similar testing of the PNADs was done on the Valduc SILENE test reactor in 2009 (Hill and Conrady, 2010). The CALIBAN results are reported here.

  17. Intercomparison of TCCON and MUSICA Water Vapour Products

    Science.gov (United States)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  18. Bico 2: second national intercomparison campaign of WBC centres working in Italy

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    During the period November 1994 - May 1995 the coordinating group of WBC centres working in Italy organised the 2. national intercalibration and intercomparison campaign. A BOMAB phantom was used filled with four radionuclides gel solution with gamma energy emissions ranging between 100 keV and 2 MeV. 17 out of 21 Italian WBC centres took part in the campaign. Through the intercalibration, organised according to internationally accepted methodologies, each WBC centre could check its own calibration procedures. many intermediate data, collected for the methodologies and measurement procedures intercomparison, permitted analyses and comparison of uncertainly causes in a WBC measurement of the internal contamination. A proposal of MDA definition and assessment procedure resulted from the intercomparison campaign [it

  19. Lessons learnt from participation in international inter-comparison exercise for environmental radioactivity measurement

    International Nuclear Information System (INIS)

    Jha, S.K.; Pulhani, Vandana; Sartandel, Sangeeta

    2016-06-01

    Environmental Radioactivity Measurement Section of Health Physics Division is regularly carrying out surveillance of the radioactivity concentration in the environment. The laboratory participates in the inter-comparison exercises conducted by various international agencies for quality assurance and quality control of analytical estimations. This report summarizes the results of the analysis of radioactivity in environmental matrices of the inter-comparison exercises. The participation in inter-comparison exercises has demonstrated competence in radionuclide identification and estimations, equivalence with the results of other participating laboratories, validated adopted analytical methods, introduced traceability to measurement etc. at national and international level. (author)

  20. The program of international intercomparison of accident dosimetry; Le programme d'intercomparaison internationale de dosimetrie d'accident 10-12 juin 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-06-01

    The French institute of radioprotection and nuclear safety (IRSN) has carried out in June 2002 an international intercomparison program for the testing of the physical and biological accident dosimetry techniques. The intercomparison is jointly organized by the IRSN and the OECD-NEA with the sustain of the European commission and the collaboration of the CEA centre of Valduc (France). About 30 countries have participated to this program. Each country has supplied its own dosimeters and biological samples which have been irradiated using the Silene reactor of CEA-Valduc or a {sup 60}Co source. These experiments allow to test the new dosimetric techniques that have been developed since the previous intercomparison program (1993) and to confirm or improve the performances of older techniques. Aside from the intercomparison exercise, this report makes a status of the known radiological accidents and of the effects of high doses of ionizing radiations on human health (symptoms, therapeutics). It explains the phenomenology of criticality accidents, the prevention means, and the history of such accidents up to the Tokai-Mura one in 1999. Finally, the dosimetry of criticality is presented with its physical and biological techniques. (J.S.)

  1. Aircraft to aircraft intercomparison during SEMAPHORE

    Science.gov (United States)

    Lambert, Dominique; Durand, Pierre

    1998-10-01

    During the Structure des Echanges Mer-Atmosphère, Propriétés des Hétérogénéités Océaniques: Recherche Expérimentale (SEMAPHORE) experiment, performed in the Azores region in 1993, two French research aircraft were simultaneously used for in situ measurements in the atmospheric boundary layer. We present the results obtained from one intercomparison flight between the two aircraft. The mean parameters generally agree well, although the temperature has to be slightly shifted in order to be in agreement for the two aircraft. A detailed comparison of the turbulence parameters revealed no bias. The agreement is good for variances and is satisfactory for fluxes and skewness. A thorough study of the errors involved in flux computation revealed that the greatest accuracy is obtained for latent heat flux. Errors in sensible heat flux are considerably greater, and the worst results are obtained for momentum flux. The latter parameter, however, is more accurate than expected from previous parameterizations.

  2. International NMR-based Environmental Metabolomics Intercomparison Exercise

    Science.gov (United States)

    Several fundamental requirements must be met so that NMR-based metabolomics and the related technique of metabonomics can be formally adopted into environmental monitoring and chemical risk assessment. Here we report an intercomparison exercise which has evaluated the effectivene...

  3. Forward Model Studies of Water Vapor Using Scanning Microwave Radiometers, Global Positioning System, and Radiosondes during the Cloudiness Intercomparison Experiment

    International Nuclear Information System (INIS)

    Mattioli, Vinia; Westwater, Ed R.; Gutman, S.; Morris, Victor R.

    2005-01-01

    Brightness temperatures computed from five absorption models and radiosonde observations were analyzed by comparing them with measurements from three microwave radiometers at 23.8 and 31.4 GHz. Data were obtained during the Cloudiness Inter-Comparison experiment at the U.S. Department of Energy's Atmospheric Radiation Measurement Program's (ARM) site in North-Central Oklahoma in 2003. The radiometers were calibrated using two procedures, the so-called instantaneous ?tipcal? method and an automatic self-calibration algorithm. Measurements from the radiometers were in agreement, with less than a 0.4-K difference during clear skies, when the instantaneous method was applied. Brightness temperatures from the radiometer and the radiosonde showed an agreement of less than 0.55 K when the most recent absorption models were considered. Precipitable water vapor (PWV) computed from the radiometers were also compared to the PWV derived from a Global Positioning System station that operates at the ARM site. The instruments agree to within 0.1 cm in PWV retrieval

  4. International intercomparison on the neutron flux density spectrum just before the REAL-80 project

    International Nuclear Information System (INIS)

    Ertek, C.

    1981-06-01

    This work briefly presents the results of the international intercomparison on the neutron flux density spectrum just before the REAL-80 intercomparison project. Some of the results of this intercomparison with a smaller number of laboratories will be also reflected in the REAL-80 project, therefore, it has some significant issues. This work is performed within the IAEA programme on standardization of reactor radiation measurements, one of the important objectives of which is the assistance of laboratories in Member States to implement or intercompare the multiple foil activation techniques for different neutron field measurements

  5. An overview of results obtained in intercomparison exercises for determination of actinides

    International Nuclear Information System (INIS)

    Benedik, L.

    2013-01-01

    In recent years the Jožef Stefan Institute participated in numerous intercomparison exercises for determination of natural and man-made radionuclides. The reported values were mostly in good agreement with the resulting reference values. This paper describes an analysis of the measurement results obtained in intercomparison exercises for determination of actinides in the period from 2009 to 2011, organised by the National Physical Laboratory and the Bundesamt für Strahlenschutz. The review covers neptunium, plutonium and americium radioisotopes over this period. - Highlights: • The goal of this study is an overview of results obtained in intercomparison exercises for determination of actinides. • The disagreement of results for Np-237 was evaluated. • Improvements in separation procedures were done

  6. Personnel-dosimetry intercomparison studies at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.

    1982-01-01

    Since 1974, seven annual personnel dosimetry intercomparison studies have been conducted at the Oak Ridge National Laboratory using the Health Physics Reactor. These studies have produced more than 2000 measurements by 72 participating organizations of neutron and gamma dose equivalents between 0.1 to 15.0 mSv in six mixed radiation fields. The relative performance of three basic types of personnel neutron dosimeters (nuclear emulsion film, thermoluminescent, and track-etch) and two basic types of gamma dosimeters (film and thermoluminescent) was assessed based on experimental results obtained during the seven intercomparisons

  7. Preparation and application of radioactive soil samples for intercomparison

    International Nuclear Information System (INIS)

    Gao Zequan; Li Zhou; Li Pengxiang; Wang Ruijun; Ren Xiaona

    2014-01-01

    This article summarized the preparation process and intercomparison results of the simulated environmental radioactive soil samples. The components of the matrix were: SiO 2 , Al 2 O 3 , Fe 2 O 3 , MgO, CaO, NaCl, KCl and TiO 2 . All of the components were milled, oven-dried, sieved and then blended together. The homogeneity test was according to GB 15000. 5-1994, and no significant differences were observed. The 3 H analysis soils were spiked natural soils with the moisture content of 15%. Eight laboratories attended this intercomparison. The results proves that the preparation of the simulated soils were suitable for the inter-laboratories comparison. (authors)

  8. The AquaVIT-1 intercomparison of atmospheric water vapor measurement techniques

    Science.gov (United States)

    Fahey, D. W.; Gao, R.-S.; Möhler, O.; Saathoff, H.; Schiller, C.; Ebert, V.; Krämer, M.; Peter, T.; Amarouche, N.; Avallone, L. M.; Bauer, R.; Bozóki, Z.; Christensen, L. E.; Davis, S. M.; Durry, G.; Dyroff, C.; Herman, R. L.; Hunsmann, S.; Khaykin, S. M.; Mackrodt, P.; Meyer, J.; Smith, J. B.; Spelten, N.; Troy, R. F.; Vömel, H.; Wagner, S.; Wienhold, F. G.

    2014-09-01

    The AquaVIT-1 intercomparison of atmospheric water vapor measurement techniques was conducted at the aerosol and cloud simulation chamber AIDA (Aerosol Interaction and Dynamics in the Atmosphere) at the Karlsruhe Institute of Technology, Germany, in October 2007. The overall objective was to intercompare state-of-the-art and prototype atmospheric hygrometers with each other and with independent humidity standards under controlled conditions. This activity was conducted as a blind intercomparison with coordination by selected referees. The effort was motivated by persistent discrepancies found in atmospheric measurements involving multiple instruments operating on research aircraft and balloon platforms, particularly in the upper troposphere and lower stratosphere, where water vapor reaches its lowest atmospheric values (less than 10 ppm). With the AIDA chamber volume of 84 m3, multiple instruments analyzed air with a common water vapor mixing ratio, by extracting air into instrument flow systems, by locating instruments inside the chamber, or by sampling the chamber volume optically. The intercomparison was successfully conducted over 10 days during which pressure, temperature, and mixing ratio were systematically varied (50 to 500 hPa, 185 to 243 K, and 0.3 to 152 ppm). In the absence of an accepted reference instrument, the absolute accuracy of the instruments was not established. To evaluate the intercomparison, the reference value was taken to be the ensemble mean of a core subset of the measurements. For these core instruments, the agreement between 10 and 150 ppm of water vapor is considered good with variation about the reference value of about ±10% (±1σ). In the region of most interest between 1 and 10 ppm, the core subset agreement is fair with variation about the reference value of ±20% (±1σ). The upper limit of precision was also derived for each instrument from the reported data. The implication for atmospheric measurements is that the

  9. Outline of the 1996-1998 IAEA co-ordinated research project on intercomparison for individual monitoring of external exposure from photon radiation

    International Nuclear Information System (INIS)

    Boehm, J.; Gustafsson, M.; Ouvrard, R.

    1999-01-01

    The outline of the IAEA Co-ordinated Research Project 1996-1998 on intercomparison for individual monitoring is described. The intercomparison focused on IAEA Member States in Eastern Europe and was based on the operational quantity personal dose equivalent, H p (10). The three phases of the intercomparison were: the preparatory phase including a workshop, the 'type-test' intercomparison, and the 'simulated workplace field' intercomparison. Details of the phases are given. (author)

  10. Initial Results of an Intercomparison of AMS-Based Atmospheric 14CO2 Measurements

    NARCIS (Netherlands)

    Miller, John; Lehman, Scott; Wolak, Chad; Turnbull, Jocelyn; Dunn, Gregory; Graven, Heather; Keeling, Ralph; Meijer, Harro A. J.; Aerts-Bijma, Anita Th; Palstra, Sanne W. L.; Smith, Andrew M.; Allison, Colin; Southon, John; Xu, Xiaomei; Nakazawa, Takakiyo; Aoki, Shuji; Nakamura, Toshio; Guilderson, Thomas; LaFranchi, Brian; Mukai, Hitoshi; Terao, Yukio; Uchida, Masao; Kondo, Miyuki

    2013-01-01

    This article presents results from the first 3 rounds of an international intercomparison of measurements of Delta(CO2)-C-14 in liter-scale samples of whole air by groups using accelerator mass spectrometry (AMS). The ultimate goal of the intercomparison is to allow the merging of Delta(CO2)-C-14

  11. Monte Carlo Simulation of Electron Beams for Radiotherapy - EGS4, MCNP4b and GEANT3 Intercomparison

    CERN Document Server

    Trindade, A; Alves, C M; Chaves, A; Lopes, C; Oliveira, C; Peralta, L

    2000-01-01

    In medical radiation physics, an increasing number of Monte Carlo codes are being used, which requires intercomparison between them to evaluated the accuracy of the simulated results against benchmark experiments. The Monte Carlo code EGS4, commonly used to simulate electron beams from medical linear accelerators, was compared with GEANT3 and MCNP4b. Intercomparison of electron energy spectra, angular and spatial distribution were carried out for the Siemens KD2 linear accelerator, at beam energies of 10 and 15 MeV for a field size of 10x10 cm2. Indirect validation was performed against electron depth doses curves and beam profiles measured in a MP3-PTW water phantom using a Markus planar chamber. Monte Carlo isodose lines were reconstructed and compared to those from commercial treatment planning systems (TPS's) and with experimental data.

  12. IAEA/SSDL intercomparison of calibration factors for therapy level ionization chambers

    International Nuclear Information System (INIS)

    Lu Jilong; Cheng Jinsheng; Guo Zhaohui; Li Kaibao

    2005-01-01

    Objective: By participating in IAEA-SSDL intercomparison, a dose to water calibration factor was introduced in order to check the measuring accuracy of 60 Co radiotherapy dose level standard and ensure the reliability and consistency of our calibration. Methods: The authors carried out both air kerma and absorbed dose to water calibrations against 60 Co γ-rays for one of our field class ionization chambers, and sent the results together with the chamber to IAEA dosimetry laboratory for calibration, then IAEA calibrated it and gave the deviation of the intercomparison. Results: The deviation of our air kerma calibration factors is -0.5%, and the deviation of our absorbed dose to water calibration factors is 0.4%. Conclusion: The deviation of calibration factors between IAEA and SSDL should be no more than ±1.5%. Therefore, the result of this intercomparison is considered satisfactory. (authors)

  13. UK laboratory intercomparison on internal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Speed, J.; Birchall, A.; Bull, R.; Cockerill, R.; Jarvis, N.S.; Marsh, J.W.; Peace, M.S.; Roberts, G.; Scarlett, C.; Spencer, D.; Stewart, P

    2003-07-01

    A laboratory intercomparison for internal dose assessment from a variety of intake scenarios is described. This is the first UK intercomparison using the revised ICRP Human Respiratory Tract and biokinetic models. Four United Kingdom laboratories participated and six cases were assessed. Overall, the agreement in internal dose assessments between laboratories was considered satisfactory with 79% of the assessed committed effective doses, e(50), for cases within a band of {+-}40% of the median value. The range (highest/lowest) in e(50) estimated by the laboratories was smallest (1.2) for a case involving inhalation of {sup 137}Cs. The range was greatest (6.0) for a case involving a wound with, and possible inhalation of, {sup 238}Pu, {sup 239}Pu and {sup 241}Am; the variation between laboratories in assessment of intakes could not be considered to be satisfactory in this case. Judgements on the most appropriate data to use in estimating intakes, choice of parameter values for use with the ICRP models and allowing for the effects of treatment with DTPA were important sources of variability between laboratories. (author)

  14. Primary standardization of cesium-137 for international intercomparison

    International Nuclear Information System (INIS)

    Srivastava, P.K.

    1977-01-01

    Primary standards of cesium-137 are of great importance for precise radiation measurements because, due to its simple decay-scheme and long half-life, it is widely used for the calibration of radiation detectors. Also 137 Cs is used for the measurement of fission-yield and uranium burn-up in reactor engineering studies. In view of these, an international intercomparison was organised on a limited scale to correlate the standards established at the Bhabha Atomic Research Centre (BARC), Bombay(India) and Physikalisch-Technische Bundesanstalt (PTB), West Germany. The ''efficiency tracing technique'' was developed at BARC for the primary standardization of 137 Cs for this intercomparison. Two tracers, namely 82 Br and 60 Co, were employed to trace the beta efficiency of the 4 πβ-γ coincidence counting system. It is shown that this technique offers high accuracy and inherent reliability. The ''tracing-technique'' for 137 Cs standardization is briefly described. The gravimetric method of dilution and preparation of mixed sources of 137 Cs - 82 Br and 137 Cs - 60 Co are given. The various counting parameters and settings are included. Data reduction and the estimation of systematic and statistical errors are discussed. The results of the intercomparison, which are also included, show that the agreement between the measurments of BARC and PTB is within 0.5%. (author)

  15. Intercomparison of characterization techniques of filter radiometers in the ultraviolet region

    International Nuclear Information System (INIS)

    Abu-Kassem, I.; Karha, P.; Harrison, N. J.; Nevas, S.; Hartree, W. S.

    2008-01-01

    Narrow-band filter radiometers at 248 nm, 313 nm, 330 nm and 368 nm wavelengths were used to compare calibration facilities of spectral (irradiance) responsivity at HUT, NPL and BNM-INM. The results are partly in agreement within the stated uncertainties. Use of demanding artefacts in the intercomparison revealed that the wavelength scales of the participating institutes deviate more than expected. Such effects cannot be seen in typical intercomparisons of spectral responsivity or spectral transmittance, where spectrally neutral samples are used.(author)

  16. Meteorological measurements and simulations by the LORAN model performed during the ETEX experiments

    International Nuclear Information System (INIS)

    Schneiter, D.; Berger, H.; Galmarini, S.

    1997-01-01

    A SODAR (SOnic Detection and Ranging) installed by the SMA at the tracer release site (Monterfil near Rennes, France) was operating continuously during the two ETEX experiments (from 22nd to 25th Oct. and from 13th to 17th Nov. 1994). Vertical profiles of the horizontal and vertical components of the wind were measured every 20 m, from 20 m above ground up to 600 m, depending on the strength of the returned echoes. Samplings were averaged over 30 minutes

  17. IAEA AQCS catalogue for reference materials and intercomparison exercises 1998/1999

    International Nuclear Information System (INIS)

    1999-01-01

    Fore more than thirty years the International Atomic Energy Agency (IAEA), through its Analytical Quality Control Services (AQCS) programme, has been assisting Member States' laboratories to maintain and improve the reliability of their analyses by organizing intercomparison exercises and by preparing and distributing biological, environmental and marine reference materials. The catalogue consists principally of two parts: The list of all available IAEA reference materials grouped into five categories: reference materials for radionuclides; reference materials for trace, minor and major elements, including oxides; reference materials for stable isotopes; reference materials for organic contaminants and methyl mercury containing materials. Lists of all available IAEA reference materials sorted by analytes. In addition information on recommended half-life data and suppliers of radioactive sources is provided. Planned intercomparisons are advertised and request forms for participation in intercomparisons are included. Forms for ordering reference materials, quality control spectra for gamma-spectrometry on diskettes and AQCS related publications are also provided

  18. International intercomparison of neutron spectra evaluating methods using activation detectors

    International Nuclear Information System (INIS)

    Fischer, A.

    1975-06-01

    The international intercomparison of neutron spectrum evaluation methods using activation detectors was organized by the IAEA in 1971 - 1972. All of the contributions and the results of a critical evaluation are presented here. The spectra of different contributors are compared to a reference spectrum by means of different integrals and weighting functions. Different cross section sets, foil numbers, energy point systems, guess spectra used by the contributors cause differences in the resulting spectra. The possible ways of separating these effects are also investigated. Suggestions are made for the organization of a new intercomparison on the basis of more uniform input data. (orig.) [de

  19. PIDIE, plutonium isotopic determination inter-comparison exercise

    International Nuclear Information System (INIS)

    Harry, R.J.S.

    1990-07-01

    PIDIE (Plutonium Isotopic Determination Inter-comparison Exercise) is one of the projects of the ESARDA Working Group on Techniques and Standards for Non-Destructive Analysis. PIDIE is placed against the historical background of the general development of international standards. Its results are also reviewed in the light of the original purpose of the project. Sets of seven sealed Pu samples of different isotopic composition, each containing 0,45 grammes, were sent to the 9 participating laboratories for three separate determinations of the unknown isotopic composition, to investigate error sources and , if possible to improve the knowledge of γ-emission probabilities. An additional question was to examine the possible improvement of such measurements using reference samples. No important bias has been observed in the results of this inter-comparison. The apparent improvement in the precision and accuracy of the result seems to arise from both better equipment and more elaborate spectrum evaluation methods. (author). 39 refs.; 1 fig.; 5 tabs

  20. Summary of 'IAEA intercomparison of IBA software'

    International Nuclear Information System (INIS)

    Barradas, N.P.; Arstila, K.; Battistig, G.; Bianconi, M.; Dytlewski, N.; Jeynes, C.; Kotai, E.; Lulli, G.; Mayer, M.; Rauhala, E.; Szilagyi, E.; Thompson, M.

    2008-01-01

    The International Atomic Energy Agency has sponsored a formal intercomparison exercise for the seven depth profiling ion beam analysis codes, which are: GISA, RUMP, RBX, DEPTH, DataFurnace, SIMNRA and MCERD. This intercomparison is published in Nucl. Instr. and Meth. B [N.P. Barradas, K. Arstila, G. Battistig, M. Bianconi, N. Dytlewski, C. Jeynes, E. Kotai, G. Lulli, M. Mayer, E. Rauhala, E. Szilagyi, M. Thompson, Nucl. Instr. and Meth. B 262 (2007) 281-303] and summarised here. The codes implement all known physical effects and they are all evaluated. We demonstrate that there is agreement between codes often better than 0.1%; and also detailed agreement with real spectra, showing in particular that the SRIM 2003 stopping powers for Si are correct to 0.6% for 1.5 MeV He. For the case of heavy ion elastic recoil detection (HI-ERD) the single scattering codes performed poorly for scattered particles, although recoiled particles were calculated correctly

  1. Report on intercomparison exercise SR-54. Determination of impurities in U3O8

    International Nuclear Information System (INIS)

    Doubek, N.; Bagliano, G.; Deron, S.

    1984-04-01

    The report presents results of a laboratory intercomparison of impurities in U 3 O 8 sample organized by the IAEA's Analytical Quality Control Service. Twelve laboratories in 11 countries sent their results. The framework of the intercomparison was therefore conceived mainly as a ''mean'' to laboratories dealing with analysis of impurities in uranium samples to check the reliability of their results. The evaluation was based on 97 laboratory means obtained with emission spectroscopy, atomic absorption techniques and neutron activation analysis. The concentration of three elements could be certified as a result of this intercomparison; informational values could be established for an additional six elements

  2. Intercomparison of methods for determining 90Sr and 137Cs in plant samples

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhao Min; Tian Guizhi

    1986-01-01

    The results of intercomparison of methods for determining 90 Sr and 137 Cs in plant samples are reported. Nine laboratories participated in the intercomparison. The samples used in intercomparison were reed and tea powders. The analytical results of 90 Sr in reed and 137 Cs in tea from different laboratories show good comparability and follow the normal-distribution. Some results reported of 137 Cs in reed are apparently lower than others. The results of 90 Sr in tea from different laboratories have poor comparability. The results obtained by HDEHP rapid extraction chromatograph appear to be too high, and it's cause is discussed. The 95% confidence intervals of content of 90 Sr and 137 Cs in reed and tea samples are given

  3. Intercomparison of radon gas detectors 1997 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck-Dempewolf, Gernot

    1998-05-01

    Between Nov 14 and Nov 20, 1997, the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut performed the 1997 Radon Intercomparison Exercise. Radon gas detectors and instruments were exposed in the PSI Radon Chamber during seven days in a reference atmosphere with an average radon gas concentration of 3860 Bqm -3 . The majority of the participants at this intercomparison were Swiss Radon Gas Measurement Laboratories acknowledged by the Swiss Federal Office for Health. Criteria for this acknowledgement are a deviation of the measurement results to the reference value below 15% (traceability criterion) and a standard deviation of the mean of five detector measurement results below 15% (reproducibility criterion). With the exception of three participants, the results of electret ionisation chambers, track etch detectors and measuring instruments fulfilled the demanded traceability and reproducibility criteria. (author)

  4. Radiocarbon intercomparison program for Chauvet Cave

    International Nuclear Information System (INIS)

    Cuzange, M.T.; Delque-Kolic, E.; Oberlin, C.; Goslar, T.; Grootes, P.M.; Nadeau, M.J.; Higham, T.; Ramsey, C.B.; Kaltnecker, E.; Paterne, M.; Valladas, H.; Van der Plicht, J.; Van der Plicht, J.; Clottes, J.; Geneste, J.M.

    2007-01-01

    We present the first results of an accelerator mass spectrometry (AMS) radiocarbon intercomparison program on 3 different charcoal samples collected in one of the hearths of the Megaceros gallery of Chauvet Cave (Ardeche, France). This cave, rich in parietal decoration, is important for the study of the appearance and evolution of prehistoric art because certain drawings have been 14 C dated to the Aurignacian period at the beginning of the Upper Paleolithic. The new dates indicate an age of about 32,000 BP, which is consistent with this attribution and in agreement with the results from the same sector of the cave measured previously at the Laboratoire des Sciences du Climat et de l'Environnement (LSCE). Six laboratories were involved in the intercomparison. Samples were measured in 4 AMS facilities: Center for Isotope Research, Groningen University, the Netherlands; the Oxford Radiocarbon Accelerator Unit, UK; the Centre de datation par le carbone 14, Univ. Claude Bernard Lyon 1, France (measured by AMS facilities of Poznan University, Poland); and the LSCE, UMR CEA-CNRS-UVSQ, France (measured by the Leibniz-Labor of Christian-Albrechts-Universitat Kiel, Germany). (authors)

  5. Intercomparison programs - a tool for the implementation of a quality assurance program in bioassay

    International Nuclear Information System (INIS)

    Mesquita, Sueli A. de; Sousa, Wanderson O.; Juliao, Ligia M.Q.C.; Santos, Maristela S.; Fernandes, Paulo C.P.

    2009-01-01

    In vitro bioassay laboratories need to have means to demonstrate that they are technically competent, operate an effective quality system, and are able to generate technically valid calibration and test results. The reliability of the results of measurements has a high influence on the reliability of the dose assessment. Inter-laboratory tests are one of the tools for assessing the analytical consistency of in vitro bioassay laboratories. The intercomparison exercises provide an opportunity to compare radiochemistry techniques for in vitro analysis of biological samples. The in vitro Laboratory of the Instituto de Radioprotecao e Dosimetria has therefore participated in the intercomparison exercises sponsored by PROCORAD, ARCAL and IAEA since 1998. The intercomparison exercises comprise measurements of gamma and beta emitters in urine samples and alpha emitters in urine and faecal samples. This paper presents the performance of the IRD in vitro bioassay laboratory in the past intercomparisons. The results demonstrate that in vitro laboratory is able to generate technically valid results, which also guarantee the support for a quality assurance program and accreditation by competent organism in Brazil. (author)

  6. 12MW Horns Rev experiment[Wind farm

    Energy Technology Data Exchange (ETDEWEB)

    Hasager, C.B.; Pena, A; Mikkelsen, T.; Courtney, M.; Antoniou, I.; Gryning, S.-E.; Hansen, P. [Risoe National Lab., DTU, Wind Energy Dept. (Denmark); Soerensen, P.B. [DONG Energy (Denmark)

    2007-10-15

    The 12MW project with the full title '12 MW wind turbines: the scientific basis for their operation at 70 to 270 m height offshore' has the goal to experimentally investigate the wind and turbulence characteristics between 70 and 270 m above sea level and thereby establish the scientific basis relevant for the next generation of huge 12 MW wind turbines operating offshore. The report describes the experimental campaign at the Horns Rev offshore wind farm at which observations from Doppler Laser LIDAR and SODAR were collected from 3 May to 24 October 2006. The challenges for mounting and operating the instruments on the transformer platform at Horns Rev were overcome by a close collaboration between DONG energy and Risoe National Laboratory DTU. The site is presented. In particular, three tall offshore meteorological masts, up to 70 m tall, provided a useful source of meteorological data for comparison to the remotely sensed wind and turbulence observations. The comparison showed high correlation. The LIDAR and SODAR wind and turbulence observations were collected far beyond the height of the masts (up to 160 m above sea level) and the extended profiles were compared to the logarithmic wind profile. Further studies on this part of the work are on-going. Technical detail on LIDAR and SODAR are provided as well as theoretical work on turbulence and atmospheric boundary layer flow. Selected results from the experimental campaign are reported. (au)

  7. Results of the third CEC intercomparison of active and passive detectors for the measurement of radon and radon decay products

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Sinnaeve, J.

    1988-01-01

    In 1982 and 1984 the radiation protection research programme of the European Communities organized intercomparisons of radon and radon daughter measurement techniques, and the results were published (Miles et al., 1983; Miles and Sinnaeve, 1986. The second of these intercomparisons was carried out as part of a wider exercise sponsored jointly by the CEC and the OECD/NEA (OECD, 1983). The third CEC intercomparison, held at the National Radiological Protection Board (NRPB) in the United Kingdom in 1987, again constituted the European regional part of this wider exercise. The intercomparison on the European region was carried out in two stages, the first for passive integrating detectors and the second for active instruments, usually by spot measurements. Twenty-one laboratories participated in the intercomparison, of passive dosimetry and 17 in that for active dosimetry. Passive detectors have been used in many European countries to carry out surveys of exposure in homes and to monitor occupational exposure. The exposures for the intercomparison of passive detectors were carried out in June, July and August 1987 at NRPB. The intercomparison of active detectors was carried out over three days in October 1987, when scientists from the participating laboratories brought their equipment to NRPB

  8. Community Intercomparison Suite (CIS) v1.4.0: A tool for intercomparing models and observations

    NARCIS (Netherlands)

    Watson-Parris, Duncan; Schutgens, Nick; Cook, Nicholas; Kipling, Zak; Kershaw, Philip; Gryspeerdt, Edward; Lawrence, Bryan; Stier, Philip

    2016-01-01

    The Community Intercomparison Suite (CIS) is an easy-to-use command-line tool which has been developed to allow the straightforward intercomparison of remote sensing, in-situ and model data. While there are a number of tools available for working with climate model data, the large diversity of

  9. Intercomparison of 131I activity measurements in nuclear medicine

    International Nuclear Information System (INIS)

    Kim, G. Y.; Yang, H. K.; Lim, C. I.; Lee, H. K.; Jeong, H. K.

    2004-01-01

    Activity measurements in nuclear medicine using a dose calibrator have been performed for several decades and their reliability has varied. To minimise the radiation dose to patients with radionuclides, it is necessary to ensure that the sample administered is accurately assayed. Recognizing the importance of intercomparison in nuclear medicine and the need to make access to activity standards traceable to the international measurement system, the KFDA, as a national secondary standard dosimetry laboratory (SSDL), started an intercomparison program in 2002. This program was initiated by survey to all nuclear medicine centres regarding general information about their dose calibrators, radioisotopes etc. 71 nuclear medicine centres (79 dose calibrators) participated in the intercomparison program with 131 I isotope. To assess the accuracy of clinical measurements of the activity of 131 I solutions and to determine the reason for the disagreement, an intercomparison was conducted using 4 ml aliquots in 10 ml P6 vial with a total activity in the region of 10 -20 MBq. The reference time of decay for all solutions was 0:00 on 25 September 2002. The half-life used was 8.04 days. For the evaluation of solution in KFDA, a sealed, high pressure and re-entrant ionisation chamber, NPL-CRC radionuclide calibrators were used. The verification of our calibration quality was by means of a comparison with the Korea Primary Standard Laboratory (KRISS). The activity ratio of KFDA to KRISS for the 131 I solutions is 1.011. The difference between the value quoted by the clinic, A hospital and the value obtained by the KFDA, A KFDA , is expressed as a percent deviation, i.e. DEV(%) 100x(A hospital -A KFDA )/A KFDA . From the data obtained it was found that 61% of the calibrators showed a deviation within +/-5%; 23% had a deviation in the range 5% 131 I solution activity measurements, using dose calibrators in Koreas, and also to provide the participants with a traceable standard to

  10. Australian participation in international intercomparisons of environmental dosemeters

    International Nuclear Information System (INIS)

    Boas, J.F.; David, R.C.; Jones, J.

    2002-01-01

    The Environmental Measurements Laboratory of the U.S. Department of Energy has conducted international intercomparisons of environmental dosemeters at regular intervals since 1974. This paper reports the results obtained in the 10th and 11th intercomparisons by JFB and JGY at the Australian Radiation Laboratory (in 1992 and 1996 respectively) and in the 12th intercomparison by JFB and DRCT at the Australian Radiation Protection and Nuclear Safety Agency and by JGY and JJ at Australian Radiation Serviceces during 2000 and 2001. The ARL/ARPANSA measurements used a simple dosemeter holder containing two CaSO 4 :Dy impregnated Teflon discs, one unshielded and the other shielded by approximately 2.4 mm of Cu. The ARS measurements used a commercially available TLD badge case containing a CaSO 4 :Dy impregnated Teflon card. The commercial badge case was not symmetrical in design. The filtration in the front and rear sections of the commercial badge case varied from an open area to an area shielded by copper, tin and cadmium. The results obtained were generally within ±15% of the reference values measured by EML using high-pressure ionisation chambers for dosemeters exposed hi the field to environmental radiation and for dosemeters given a single exposure to 137 Cs or 241 Am at EML or an associated laboratory. Similar agreement was obtained for dosemeters exposed in the field and also given a single exposure to 137 Cs radiation. In order to obtain this measure of agreement, the dosemeters were individually calibrated and the readouts corrected for fading. Copyright (2002) Australasian Radiation Protection Society Inc

  11. Preliminary report: STOIC CGCM intercomparison - equatorial sections

    International Nuclear Information System (INIS)

    Davey, M; Huddleston, M; Sperber, K R.

    1999-01-01

    An intercomparison and assessment of the tropical behaviour of coupled general circulation models (CGCMs) is being carried out, to identify common strengths and weaknesses and thus guide future CGCM development. The work is being carried out as part of the CLIVAR climate research programme, as a WG-SIP (Working Group on Seasonal to Interannual Prediction) project called STOIC (Study of Tropical Oceans In CGCMs), organised by Michael Davey. This project complements a companion sub-project called ENSIP (El Ni no Simulation Intercomparison Project) organised by Mojib Latif (Max- Planck-Institute for Meteorology) that focusses on equatorial Pacific CGCM behaviour (Latif et al. 1999). Previous coupled model assessments (Mechoso et al. 1995, Neelin et al. 1992, and ENSIP) have focussed on tropical Pacific behaviour. The aim of STOIC is to look at model performance in all tropical ocean regions. This status report contains a sample of the STOIC assessment work, highlighting mean and inter- annual equatorial sea surface temperatures and zonal windstresses. The intention is to submit STOIC and ENSIP papers in mid-1999 for publication together in a refereed journal

  12. Environmental radioactivity measurement intercomparison exercise 1990

    International Nuclear Information System (INIS)

    Jerome, S.M.

    1991-05-01

    In a recent national intercomparison exercise, 49 laboratories involved in making environmental radioactivity measurements took part in the analysis of samples supplied by the National Physical Laboratory (NPL) in the United Kingdom. There were two sets of samples; one containing pure β-emitters and one containing β/γ-emitters. Two thirds of the participants measured the β/γ-emitter sample only, the remainder measured both. The results are presented. (author)

  13. Intercomparison of Aerosol Optical Depth from Brewer Ozone spectrophotometers and CIMEL sunphotometers measurements

    Directory of Open Access Journals (Sweden)

    A. Cheymol

    2009-01-01

    Full Text Available The Langley plot method applied on the Brewer Ozone measurements can provide accurate Aerosol Optical Depth (AOD in the UV-B. We present seven intercomparisons between AOD retrieved from Brewer Ozone measurements at 320 nm and AOD measured by CIMEL sunphotometer at 340 nm or 440 nm (shifted to 320 nm in using the Angström's law, which are stored in the international AERONET database. Only the intercomparisons between co-located instruments can be used to validate the Langley Plot Method applied to the Brewer measurements: in this case, all the correlation coefficients are above 0.82. If the instruments are not at the same site, the correlation between the AOD retrieved by both instruments is much lower. In applying the Angström's law the intercomparison is improved compared to previous study.

  14. Asian/Australasian region intercalibration and intercomparison programme for radon, thoron and daughters. Asian/Australasian region radon intercomparison, September 1987 - September 1988

    Energy Technology Data Exchange (ETDEWEB)

    Peggie, J.R.; Gan, Tianghong; Solomon, S.B.

    1993-05-01

    The International Intercalibration and Intercomparison Programme for radon, thoron and daughters monitoring equipment, abbreviated IIIP, was a programme organized jointly by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development and the Radiation Protection Research Programme of the Commission of European Communities. The broad purpose of the IIIP was to determine if the diverse calibration procedures used in different countries were equivalent. The general approach was to select four regional reference laboratories and entrust then with the details of project definition and execution. The Australian Radiation Laboratory (ARL) was selected to co-ordinate IIIP activities between OECD member countries in the Pacific region. As the regional programme precluded the participation of non-OECD member countries in the Western Pacific Region, an intercomparison series for radon was initiated by ARL in 1987 between twenty eight laboratories from nine countries in the Asian/Australasian region. The methodology and protocols for grab sampler, solid state nuclear track detectors (SSNTD) and charcoal measurements are described in this report. Generally the results showed reasonable agreement between the majority of laboratories for grab sampler measurements consistent with previous intercomparison. However there were large systematic differences in the results of the passive monitors for some laboratories. For all samplers, it was found that the overall random uncertainty or replication error, which included random uncertainties associated with the counting and calibration, were the main sources of variability between individual measurements of participants and the ARL reference value, with calibration uncertainties predominating. 23 tabs.

  15. Asian/Australasian region intercalibration and intercomparison programme for radon, thoron and daughters. Asian/Australasian region radon intercomparison, September 1987 - September 1988

    International Nuclear Information System (INIS)

    Peggie, J.R.; Gan, Tianghong; Solomon, S.B.

    1993-05-01

    The International Intercalibration and Intercomparison Programme for radon, thoron and daughters monitoring equipment, abbreviated IIIP, was a programme organized jointly by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development and the Radiation Protection Research Programme of the Commission of European Communities. The broad purpose of the IIIP was to determine if the diverse calibration procedures used in different countries were equivalent. The general approach was to select four regional reference laboratories and entrust then with the details of project definition and execution. The Australian Radiation Laboratory (ARL) was selected to co-ordinate IIIP activities between OECD member countries in the Pacific region. As the regional programme precluded the participation of non-OECD member countries in the Western Pacific Region, an intercomparison series for radon was initiated by ARL in 1987 between twenty eight laboratories from nine countries in the Asian/Australasian region. The methodology and protocols for grab sampler, solid state nuclear track detectors (SSNTD) and charcoal measurements are described in this report. Generally the results showed reasonable agreement between the majority of laboratories for grab sampler measurements consistent with previous intercomparison. However there were large systematic differences in the results of the passive monitors for some laboratories. For all samplers, it was found that the overall random uncertainty or replication error, which included random uncertainties associated with the counting and calibration, were the main sources of variability between individual measurements of participants and the ARL reference value, with calibration uncertainties predominating. 23 tabs

  16. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, E.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

  17. Criticality accident dosimetry systems: an international intercomparison at the SILENE reactor in 2002.

    Science.gov (United States)

    Médioni, R; Asselineau, B; Verrey, B; Trompier, F; Itié, C; Texier, C; Muller, H; Pelcot, G; Clairand, I; Jacquet, X; Pochat, J L

    2004-01-01

    In criticality accident dosimetry and more generally for high dose measurements, special techniques are used to measure separately the gamma ray and neutron components of the dose. To improve these techniques and to check their dosimetry systems (physical and/or biological), a total of 60 laboratories from 29 countries (America, Europe, Asia) participated in an international intercomparaison, which took place in France from 9 to 21 June 2002, at the SILENE reactor in Valduc and at a pure gamma source in Fontenay-aux-Roses. This intercomparison was jointly organised by the IRSN and the CEA with the help of the NEA/OCDE and was partly supported by the European Communities. This paper describes the aim of this intercomparison, the techniques used by the participants and the two radiation sources and their characteristics. The experimental arrangements of the dosemeters for the irradiations in free air or on phantoms are given. Then the dosimetric quantities measured and reported by the participants are summarised, analysed and compared with the reference values. The present paper concerns only the physical dosimetry and essentially experiments performed on the SILENE facility. The results obtained with the biological dosimetry are published in two other papers of this issue.

  18. BIPM project: Intercomparison of water triple-point cells

    Science.gov (United States)

    Chattle, M. V.; Butler, J.

    1994-12-01

    The paper presents the results of an intercomparison between 3 triple point of water cells circulated by the Bureau International des Poids et Measures (BIPM), and a cell which is one of those used as a reference cell at the National Physical Laboratory (NPL). All 4 cells were prepared, stored and measured in the manner normally adopted at NPL. The results of the intercomparison show that over the course of about 6 weeks the temperatures of the 3 circulated cells generally agreed within 0.20 mK, with a maximum difference of 0.27(7) mK. Over the same period, the total variations of temperature measured in the 3 individual cells were 0.04 mK, 0.08 mK and 0.18 mK, respectively; the NPL cell varied by 0.10 mK. Gallium point measurements made over a similar period confirmed that these differences were partly due to small drifts in the thermometer resistance or in the measuring system.

  19. Intercomparison 2003 for Radon measurement services at PSI

    CERN Document Server

    Butterweck, G

    2003-01-01

    Twelve radon measurement services participated in the 2003 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut (PSI) during March 13th to 24th, 2003. Ten of these laboratories were approved by the Swiss Federal Office of Public Health and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas detectors (etched-track and electret ionisation chambers) and instruments (ionisation chambers and electrostatic precipitation) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 1950 Bqm sup - sup 3 leading to a radon gas exposure of 517 kBqhm sup - sup 3. Additional five electret-detectors of an approved measuring service were purchased by the Swiss Federal Office of Public Health for a spot check. Two of these were exposed as described above, two had an exposure of 247 kBqhm sup - sup 3 at an average radon concen...

  20. Intercomparison Measurements Zavazna Poruba '98

    International Nuclear Information System (INIS)

    Kostial, J.; Nemcovic, V.; Cabanekova, H.; Durcik, M.; Svatosova, O.; Fueloep, M.; Buban, P.; Galbavy, V.; Dzubara, M.; Svatos, J.

    1998-01-01

    The periodical intercomparison exercises of mobile radiological laboratories was organized in order to improve the measuring methods and to gain a good basis for quality assurance. 20 teams from 10 countries were registered for the workshop from which 20 arrived and participated only as observers. There altogether 73 participants. The list of participants is enclosed in and of this report. The aims of 1998 intercomparison measurements were: (1) to compare the results of the measurements by in-situ spectrometry assuming the different distribution; (2) to improve cooperation among different institutions in Europe; (3) to test the ability of the teams to produce results at the spot; (4) to test the teams capability to produce results for Cs-137 with real distribution without having soil density and alpha/ro prior measurement. The program of the workshop consisted from two parts: field exercises and presentations. Field exercises were: (1) In-situ gamma spectrometry of natural and artificial radionuclides and their contribution to ambient dose rate over an area with heterogeneous distribution of the contamination of cesium-137 at Zavazna Poruba. (2) Dose rate measurement from cobalt-60 source; (3) Identification and determination of activity and depth of a buried source by in-situ spectrometry; (4) Search for lost sources by mobile radiological laboratory; (6) In-situ measurements and dose rate measurement above the water-level of Liptovska Mara; (6) In-situ gamma spectrometry on the bank of the dam an area Liptovsky Trnovec

  1. Statistical intercomparison of global climate models: A common principal component approach with application to GCM data

    International Nuclear Information System (INIS)

    Sengupta, S.K.; Boyle, J.S.

    1993-05-01

    Variables describing atmospheric circulation and other climate parameters derived from various GCMs and obtained from observations can be represented on a spatio-temporal grid (lattice) structure. The primary objective of this paper is to explore existing as well as some new statistical methods to analyze such data structures for the purpose of model diagnostics and intercomparison from a statistical perspective. Among the several statistical methods considered here, a new method based on common principal components appears most promising for the purpose of intercomparison of spatio-temporal data structures arising in the task of model/model and model/data intercomparison. A complete strategy for such an intercomparison is outlined. The strategy includes two steps. First, the commonality of spatial structures in two (or more) fields is captured in the common principal vectors. Second, the corresponding principal components obtained as time series are then compared on the basis of similarities in their temporal evolution

  2. An intercomparison exercise on radionuclides in sediment samples

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, S.P.

    1996-07-01

    An intercomparison exercise on artificial and natural radionuclides in two sediment samples, one from the Baltic Sea and one from the Kattegat, has been carried out under the EKO-1 project or the Nordic Safety Research Programme (NKS) for the period 1996-97. The measurement techniques have included direct gamma-ray spectrometry with Ge and NaI detectors, and radiochemical procedures followed by beta counting and alpha spectrometry. The participants have 21 laboratories. Results were submitted for Cs-137, Cs-134, Co-60, Sb-125, Pu-239,240, Pu-238, Am-241, Sr-90, Ra-226, Th-232 and K-40, Pb-210, Po-210 and U-235. The analytical performance of the participants was evaluated for those radionuclides where six or more data sets were received. Statistical tests were made to see if individual results agreed with overall average radionuclide concentrations in the two sediment materials within target standard deviations. The results of these tests show that for Cs-137, Cs-134, Ra-226, Th-232 and K-40 the analytical performance criteria were not met for 20-40% of the data sets. For plutonium isotopes the tests show that the performance criteria were not met for 13% of the data sets. Tests of overall analytical performance show that 61% of the data sets do not meet the combined performance criteria. This shows that there is room for considerable improvement of analytical quality for most of the laboratories that have participated in this intercomparison. The intercomparison exercise has furthermore demonstrated several elementary problems in analytical work. (au) 57 tabs., 16 ills., 1 ref.

  3. An intercomparison exercise on radionuclides in sediment samples

    International Nuclear Information System (INIS)

    Nielsen, S.P.

    1996-07-01

    An intercomparison exercise on artificial and natural radionuclides in two sediment samples, one from the Baltic Sea and one from the Kattegat, has been carried out under the EKO-1 project or the Nordic Safety Research Programme (NKS) for the period 1996-97. The measurement techniques have included direct gamma-ray spectrometry with Ge and NaI detectors, and radiochemical procedures followed by beta counting and alpha spectrometry. The participants have 21 laboratories. Results were submitted for Cs-137, Cs-134, Co-60, Sb-125, Pu-239,240, Pu-238, Am-241, Sr-90, Ra-226, Th-232 and K-40, Pb-210, Po-210 and U-235. The analytical performance of the participants was evaluated for those radionuclides where six or more data sets were received. Statistical tests were made to see if individual results agreed with overall average radionuclide concentrations in the two sediment materials within target standard deviations. The results of these tests show that for Cs-137, Cs-134, Ra-226, Th-232 and K-40 the analytical performance criteria were not met for 20-40% of the data sets. For plutonium isotopes the tests show that the performance criteria were not met for 13% of the data sets. Tests of overall analytical performance show that 61% of the data sets do not meet the combined performance criteria. This shows that there is room for considerable improvement of analytical quality for most of the laboratories that have participated in this intercomparison. The intercomparison exercise has furthermore demonstrated several elementary problems in analytical work. (au) 57 tabs., 16 ills., 1 ref

  4. Analysis of the REAL-84 intercomparison exercise

    International Nuclear Information System (INIS)

    1987-10-01

    The document presents the conclusions and the recommendations of the specialists' meeting organized by the IAEA and held in Jackson Hole (USA) between 27-29 May 1987 as a result of the analysis of the REAL-84 intercomparison exercise for improving the accuracy in radiation damage predictions in the neutron environment using good quality input data and proper calculation methods. 6 refs

  5. An intercomparison of Canadian external dosimetry processors for radiation protection

    International Nuclear Information System (INIS)

    1989-10-01

    The five Canadian external dosimetry processors have participated in a two-stage intercomparison. The first stage involved dosimeters to known radiation fields under controlled laboratory conditions. The second stage involved exposing dosimeters to radiation fields in power reactor working environments. The results for each stage indicated the dose reported by each processor relative to an independently determined dose and relative to the others. The results of the intercomparisons confirm the original supposition: namely that the average differences in reported dose among five processors are much less than the uncertainty limits recommended by the ICRP. This report provides a description of the experimental methods as well as a discussion of the results for each stage. The report also includes a set of recommendations

  6. Intercomparisons in the radiation monitoring network of the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Tuckova, S; Malatova, I [National Radiation Protection Inst., Prague (Czech Republic); Drabova, D [State Office for Nuclear Safety, Prague (Czech Republic)

    1996-12-31

    In Czech Republic, altogether 11 laboratories, equipped by semiconductor gamma spectrometry supply regularly to the Centre of Radiation Monitoring Network the measured data about the radionuclide activity concentration in different environmental samples, participating thus in monitoring of radiation situation in the country. The Center of Radiation Monitoring Network of Czech Republic periodically organizes through its reference laboratories interlaboratory comparison tests ensuring thus quality of the measurements within the radiation monitoring network. A ring intercomparison test was organized in 1994. The piece of steel rather highly contaminated by {sup 60}Co was used. In the intercomparison test 1994-1995 of pulverized concrete breeze-block containing fly ash with natural radionuclides were used. Results of this measurement is given as an example (authors).

  7. The Carbon Dioxide Removal Model Intercomparison Project (CDRMIP): rationale and experimental protocol for CMIP6

    Science.gov (United States)

    Keller, David P.; Lenton, Andrew; Scott, Vivian; Vaughan, Naomi E.; Bauer, Nico; Ji, Duoying; Jones, Chris D.; Kravitz, Ben; Muri, Helene; Zickfeld, Kirsten

    2018-03-01

    The recent IPCC reports state that continued anthropogenic greenhouse gas emissions are changing the climate, threatening severe, pervasive and irreversible impacts. Slow progress in emissions reduction to mitigate climate change is resulting in increased attention to what is called geoengineering, climate engineering, or climate intervention - deliberate interventions to counter climate change that seek to either modify the Earth's radiation budget or remove greenhouse gases such as CO2 from the atmosphere. When focused on CO2, the latter of these categories is called carbon dioxide removal (CDR). Future emission scenarios that stay well below 2 °C, and all emission scenarios that do not exceed 1.5 °C warming by the year 2100, require some form of CDR. At present, there is little consensus on the climate impacts and atmospheric CO2 reduction efficacy of the different types of proposed CDR. To address this need, the Carbon Dioxide Removal Model Intercomparison Project (or CDRMIP) was initiated. This project brings together models of the Earth system in a common framework to explore the potential, impacts, and challenges of CDR. Here, we describe the first set of CDRMIP experiments, which are formally part of the 6th Coupled Model Intercomparison Project (CMIP6). These experiments are designed to address questions concerning CDR-induced climate reversibility, the response of the Earth system to direct atmospheric CO2 removal (direct air capture and storage), and the CDR potential and impacts of afforestation and reforestation, as well as ocean alkalinization.>

  8. The second EURADOS intercomparison of national network systems used to provide early warning of a nuclear accident

    International Nuclear Information System (INIS)

    Saez-Vergara, J. C.; Thompson, I. M. G.; Gurriaran, R.; Dombrowski, H.; Funck, E.; Neumaier, S.

    2007-01-01

    In 1999 and 2002, the EURADOS Working Group on Environmental Monitoring organised two European intercomparison exercises of national network systems used to provide early warning in case of a nuclear accident. In total, 12 European countries, represented by more than 40 scientists, participated in these two intercomparisons with more than 35 different dose rate detectors. In addition, an in situ gamma spectrometry intercomparison was performed by a group of European scientists during the 2002 exercise. Results of these spectrometry measurements will be reported elsewhere. This report summarises the results of the second intercomparison, performed in 2002, at the environmental dosimetry facilities of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The unique combination of the ultra-low background Underground Laboratory (UDO) and two free-field sites (a floating platform on a lake showing an almost pure cosmic radiation field and a free-field gamma ray irradiation facility) provide the particular opportunity to precisely quantify the inherent background of the detectors and to calibrate them almost free of any background and traceable to PTB's primary standards. In addition, the intercomparison comprised investigations on the energy and dose rate dependence of the detectors' response to gamma radiation as well as on the response to cosmic radiation. Finally, the sensitivity of the detector systems to small dose rate variations, similar to that caused by a passing overhead radioactive plume, was studied under realistic free-field conditions. Following the Council Directive 96/29/EURATOM, the participants of the 2002 intercomparison were asked to report their results in terms of the operational quantity ambient dose equivalent, H*(10). Although the verification of the individual calibrations showed smaller discrepancies than those in the 1999 intercomparison, in a few cases, these discrepancies would be still unacceptably high in the case of a real

  9. Intercomparison of ozone measurements between Lidar and ECC-sondes

    Energy Technology Data Exchange (ETDEWEB)

    Grabbe, G.C. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Boesenberg, J. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Dier, H. [Meteorologisches Obs., Lindenberg (Germany); Goersdorf, U. [Meteorologisches Obs., Lindenberg (Germany); Matthias, V. [Max-Planck-Institut fuer Meteorologie, Hamburg (Germany); Peters, G. [Meteorologisches Obs., Lindenberg (Germany); Schaberl, T. [Hamburg Univ. (Germany). Meteorologisches Inst.; Senff, C. [Hamburg Univ. (Germany). Meteorologisches Inst.

    1996-02-01

    An intercomparison experiment for measurements of ozone vertical profiles in the lower troposphere was performed using a ground-based ozone DIAL (DIfferential Absorption Lidar) and ECC-sondes (Electrochemical Concentration Cell) attached to tethered as well as free flying balloons, which took place in June of 1994. The tethered balloon was used for ozone soundings in the planetary boundary layer up to an altitude of 500 m, while in the free troposphere free flying balloons were used. For the time series of up to 90 min obtained with the tethersondes both averages and standard deviations are compared. The mean difference for all measurements amounted to 3.5 {mu}g/m{sup 3} only, corresponding to 3.5%. For the instantaneous profiles compared to the free flying sondes the differences were only marginally larger, with a mean value of 3.6 {mu}g/m{sup 3} corresponding to 4.1%. With two exceptions all averages for a single profile stayed below 7 {mu}g/m{sup 3}. Larger individual excursions were observed. In some cases, in particular in regions of steep aerosol gradients at layer boundaries, most probably the lidar values cause the deviation, while in other cases the ECC-sonde is suspected to yield erroneous results. For the measured standard deviation those retrieved from DIAL measurements are generally larger than measured by the ECC-sondes, especially in regions of inhomogeneous aerosol distribution. For the measurements reported here, this is attributed to residual errors in the aerosol correction of the DIAL measurements. The general agreement found in this intercomparison is regarded as excellent, DIAL is proven to be a very valuable tool for detailed studies of the ozone distribution in the lower troposphere. (orig.)

  10. Photon dosimetry intercomparisons at Tygerberg and Groote Schuur hospitals

    International Nuclear Information System (INIS)

    Jones, D.T.L.; Symons, J.E.; Schreuder, A.N.; Van der Merwe, E.J.; Rossouw, A.; Hough, J.K.; Lazarus, G.L.

    1994-08-01

    A national photon dosimetry intercomparison was undertaken at 8 hospitals at the beginning of 1989 prior to the commencement of randomised clinical trials involving neutron therapy at the National Accelerator Centre. The results obtained were in agreement at all but two hospitals. Following these studies it was agreed that a uniform photon dosimetry protocol, the AAPM TG2 protocol, be adopted countrywide. The clinical program at the National Accelerator Centre is now far advanced and it was deemed appropriate to undertake a new photon dosimetry intercomparison at two local hospitals, through which all patients are referred. The procedure involved was to compare the doses measured at each hospital under specified conditions by National Accelerator staff with the doses measured by the hospital physicists using their own equipment and protocols. The results obtained were in good agreement, confirming the validity of the dosimetry techniques used. 8 refs., 8 tabs

  11. Analysis of international intercomparisons results organized by Japan for integrating 222Rn-220Rn detectors

    International Nuclear Information System (INIS)

    Wu Yunyun; Cui Hongxing; Zhang Qingzhao; Shang Bing; Su Xu

    2012-01-01

    Objective: To guarantee the quality of measurements with the radon-thoron discriminative detectors of our laboratory. Methods: LD-P radon-thoron discriminative detector participated in the international intercomparison for integrating radon/thoron detectors organized by National Institute of Radiological Science (NIRS, Japan). Detectors were sent to NIRS for exposure. Radon intercomparison was conducted with radon chamber providing three levels of exposure: low, medium and high levels. Thoron intercomparison was carried out at thoron chamber, which also provided three levels of exposure: low, medium and high levels. Detectors were posted back to our laboratory for etching and analysis after exposure. Then the measured values were submitted to NIRS. Finally the reference values were informed of us. Results: The relative percent difference (RPD) between the measured value and the reference value for radon was -13.8%, -14.4% and -17.1% at low, medium and high levels respectively, and that of thoron were -14.4%, 8.9% and -3.2% at three levels respectively. Conclusions: Both radon and thoron measurement of our detectors rank as 'Category Ⅰ' in the 4th international intercomparisons for integrating radon/thoron detectors with the NIRS radon/thoron chambers. (authors)

  12. Review and intercomparison of operational methods for the determination of the mixing height

    DEFF Research Database (Denmark)

    Seibert, P.; Beyrich, F.; Gryning, Sven-Erik

    2000-01-01

    The height of the atmospheric boundary layer (ABL) or the mixing height (MH) is a fundamental parameter characterising the structure of the lower troposphere. Two basic possibilities for the practical determination of the MH are its derivation from profile data (measurements or numerical model...... output) and its parameterisation using simple equations or models (which only need a few measured input values). Different methods suggested in the literature are reviewed in this paper. The most important methods have been tested on data sets from three different sites in Europe (Cabauw - NL, Payerne...... - CH, Melpitz - D). Parcel and Richardson number methods applied to radiosonde profiles and the analysis of sodar and wind profiler data have been investigated. Modules for MH determination implemented in five currently used meteorological preprocessors for dispersion models have been tested, too...

  13. New-particle formation events in a continental boundary layer: first results from the SATURN experiment

    Directory of Open Access Journals (Sweden)

    F. Stratmann

    2003-01-01

    Full Text Available During the SATURN experiment, which took place from 27 May to 14 June 2002, new particle formation in the continental boundary layer was investigated. Simultaneous ground-based and tethered-balloon-borne measurements were performed, including meteorological parameters, particle number concentrations and size distributions, gaseous precursor concentrations and SODAR and LIDAR observations. Newly formed particles were observed inside the residual layer, before the break-up process of the nocturnal inversion, and inside the mixing layer throughout the break-up of the nocturnal inversion and during the evolution of the planetary boundary layer.

  14. The April 1994 and October 1994 radon intercomparisons at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Perry, P.M.; Keller, H.W.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities and foreign institutions participated in these exercises. The majority of the participant's results were within ±10% of the EML value at radon concentrations of 570 and 945 Bq m -3

  15. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  16. Intercomparison I

    International Nuclear Information System (INIS)

    Cortes P, A.; Garcia D, O.; Becerril V, A.

    1997-01-01

    Assuming the importance that have the use of measurement procedures which yield consistent results with other laboratories it is necessary to participate in international intercomparisons. In this time, the Radioactive patterns laboratory (LPR) at Metrology Department of National Institute of Nuclear Research participated in the Quality Appraisement Program (QAP) which was organized by the Energy Department of the United States in march 1997. In this program soil samples, vegetables and contaminated air filters were distributed with different radioisotopes. This laboratory took part in the measurement and analysis of one of the air filters. This filter was contaminated with 12 radioisotopes, 7 β emissors, 4 α and γ emissors and a β pure emissor. The β - γ emissors were measured with a gamma spectrometer system with a Ge high purity detector. From the 7 activity measurements corresponding to the β, γ emissors were qualified as acceptable. In this work, the used equipment is described and the procedure followed is reported for the problem filter measurement as well as the obtained results. (Author)

  17. ACTRIS non-methane hydrocarbon intercomparison experiment in Europe to support WMO GAW and EMEP observation networks

    Science.gov (United States)

    Hoerger, C. C.; Claude, A.; Plass-Duelmer, C.; Reimann, S.; Eckart, E.; Steinbrecher, R.; Aalto, J.; Arduini, J.; Bonnaire, N.; Cape, J. N.; Colomb, A.; Connolly, R.; Diskova, J.; Dumitrean, P.; Ehlers, C.; Gros, V.; Hakola, H.; Hill, M.; Hopkins, J. R.; Jäger, J.; Junek, R.; Kajos, M. K.; Klemp, D.; Leuchner, M.; Lewis, A. C.; Locoge, N.; Maione, M.; Martin, D.; Michl, K.; Nemitz, E.; O'Doherty, S.; Pérez Ballesta, P.; Ruuskanen, T. M.; Sauvage, S.; Schmidbauer, N.; Spain, T. G.; Straube, E.; Vana, M.; Vollmer, M. K.; Wegener, R.; Wenger, A.

    2015-07-01

    The performance of 18 European institutions involved in long-term non-methane hydrocarbon (NMHC) measurements in ambient air within the framework of the Global Atmosphere Watch (GAW) and the European Monitoring and Evaluation Programme (EMEP) was assessed with respect to data quality objectives (DQOs) of ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network) and GAW. Compared to previous intercomparison studies the DQOs define a novel approach to assess and ensure a high quality of the measurements. Having already been adopted by GAW, the ACTRIS DQOs are demanding with deviations to a reference value of less than 5 % and a repeatability of better than 2 % for NMHC mole fractions above 0.1 nmol mol-1. The participants of the intercomparison analysed two dry gas mixtures in pressurised cylinders, a 30-component NMHC mixture in nitrogen (NMHC_N2) at approximately 1 nmol mol-1 and a whole air sample (NMHC_air), following a standardised operation procedure including zero- and calibration gas measurements. Furthermore, participants had to report details on their instruments and assess their measurement uncertainties. The NMHCs were analysed either by gas chromatography-flame ionisation detection (GC-FID) or by gas chromatography-mass spectrometry (GC-MS). For the NMHC_N2 measurements, 62 % of the reported values were within the 5 % deviation class corresponding to the ACTRIS DQOs. For NMHC_air, generally more frequent and larger deviations to the assigned values were observed, with 50 % of the reported values within the 5 % deviation class. Important contributors to the poorer performance in NMHC_air compared to NMHC_N2 were a more complex matrix and a larger span of NMHC mole fractions (0.03-2.5 nmol mol-1). The performance of the participating laboratories were affected by the different measurement procedures such as the usage of a two-step vs. a one-step calibration, breakthroughs of C2-C3 hydrocarbons in the focussing trap, blank values in zero

  18. Beta dosimetry using partial body dosimeters II. Results of intercomparison measurements of 1998/1999 - PTB report

    International Nuclear Information System (INIS)

    Ambrosi, P.; Helmstaedter, K.

    2000-12-01

    In 1998 the PTB organised a second series of intercomparison measurements for selected beta dosimeters worn on the extremities. In April 1999 these intercomparison measurements and the results obtained were discussed in a one day meeting. The contributions given and the results obtained and the conclusions drawn after extensive discussions are presented in this PTB report. (orig.) [de

  19. Report on the intercomparison for the isotope standards limestone KH 2 and polyethylene foil PEF 1

    International Nuclear Information System (INIS)

    Gerstenberger, H.; Herrmann, M.

    1983-01-01

    The isotope abundance of 13 C and 18 O of a carbonate was measured by an intercomparison in order to create a new working standard for the mass spectrometric determination of isotopic variations in natural materials. For the same purpose a polyethylene was subjected an intercomparison and the abundance of 13 C and D has been determined. (author)

  20. Preliminary report on an intercomparison of methods for processing Ge(Li) gamma-ray spectra

    International Nuclear Information System (INIS)

    Parr, R.M.; Houtermans, H.; Schaerf, K.

    1978-01-01

    An intercomparison has been organized by the IAEA for the purpose of evaluating methods for processing Ge(Li) gamma-ray spectra. These spectra cover an energy range of about 1MeV and, with one exception, contain only well separated single peaks; another spectrum contains double peaks with various relative intensities and degrees of overlap. The spectra were prepared in such a way that the areas and positions of all peaks, relative to a standard spectrum which is also provided, are known exactly. The intercomparison enables the user to test the ability of his methods (1) to detect small peaks near the limit of detectability; (2) to determine the position and area of more easily detectable peaks, and (3) to determine the position and area of overlapping double peaks. The method of preparation of the spectra and the organization of the intercomparison are described in this report. (author)

  1. Total ozone measurement: Intercomparison of prototype New Zealand filter instrument and Dobson spectrophotometer

    Science.gov (United States)

    Basher, R. E.

    1978-01-01

    A five month intercomparison showed that the total ozone amounts of a prototype narrowband interference filter instrument were 7% less than those of a Dobson instrument for an ozone range of 0.300 to 0.500 atm cm and for airmasses less than two. The 7% bias was within the intercomparison calibration uncertainty. An airmass dependence in the Dobson instrument made the bias relationship airmass-dependent but the filter instrument's ozone values were generally constant to 2% up to an airmass of four. Long term drift in the bias was negligible.

  2. HPLC/DAD Intercomparison on Phytoplankton Pigments (HIP-1, HIP-2, HIP-3 and HIP-4)

    OpenAIRE

    CANUTI Elisabetta; RAS Josephine; GRUNG Merete; ROTTGERS Rudiger; COSTA GOELA Priscilla; ARTUSO Florinda; CATALDI Dario

    2016-01-01

    From 2009 to 2015, in the context of the MERIS (Medium Resolution Imaging Spectrometer) validation activities, the JRC Marine Optical Laboratory organised four HPLC Intercomparison exercises for Phytoplankton Pigment measurements (HIP-1, HIP-2, HIP-3 and HIP-4), involving seven European accredited and reference laboratories. The objectives of these intercomparison exercises were: creating a reference community at European level for phytoplankton pigment analysis capable of supporting satel...

  3. Preliminary results of the alpha particle registration intercomparison ALRIT

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1976-01-01

    In view of the widespread interest in alpha particle registration with solid state nuclear track detectors, an international intercomparison of such measurements has been arranged. Sixteen sets of fourteen detectors each were sent to GSF-Neuherberg, there irradiated carefully with different alpha particle fields, and then returned for evaluation. Fourteen irradiation runs were made for each set simulating seven different irradiation situations commonly encountered in practical applications. The preliminary results of this intercomparison reported in this paper are based on the results of eight sets. They show good agreement with respect to the determination of track densities in the case of vertical incident alpha particles. Also the results obtained for determination of particle energies and angle of incidence in most cases were rather accurate. However, apparently it is still rather difficult to determine accurately and precisely the specific activity of alpha emitters on a thick filter positioned at some distance, i.e. for the case of 2π-incidence and a broad energy spectrum. (orig.) [de

  4. Summary of 'IAEA intercomparison of IBA software'

    Energy Technology Data Exchange (ETDEWEB)

    Barradas, N.P. [Instituto Tecnologico e Nuclear, 2686-953 Sacavem (Portugal); Centro de Fisica Nuclear da Universidade de Lisboa, Av. 1649-003 Lisboa (Portugal); Arstila, K. [K.U.Leuven, Instituut voor Kern- en Stralingsfysica, B-3001 (Belgium); Battistig, G. [MFA Research Institute for Technical Physics and Material Science, H-1525 Budapest (Hungary); Bianconi, M. [CNR-IMM-Sezione di Bologna, Via P.Gobetti, 101, I-40129 Bologna (Italy); Dytlewski, N. [International Atomic Energy Agency, Wagramer Strasse 5, A-1400 Vienna (Austria); Jeynes, C. [University of Surrey Ion Beam Centre, Guildford GU2 7XH, England (United Kingdom)], E-mail: c.jeynes@surrey.ac.uk; Kotai, E. [KFKI Research Institute for Particle and Nuclear Physics, H-1525 Budapest (Hungary); Lulli, G. [CNR-IMM-Sezione di Bologna, Via P.Gobetti, 101, I-40129 Bologna (Italy); Mayer, M. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Rauhala, E. [Accelerator Laboratory, Department of Physics, University of Helsinki, FIN-00014 (Finland); Szilagyi, E. [KFKI Research Institute for Particle and Nuclear Physics, H-1525 Budapest (Hungary); Thompson, M. [Department of MS and E/Bard Hall 328, Cornell University, Ithaca, NY 14853 (United States)

    2008-04-15

    The International Atomic Energy Agency has sponsored a formal intercomparison exercise for the seven depth profiling ion beam analysis codes, which are: GISA, RUMP, RBX, DEPTH, DataFurnace, SIMNRA and MCERD. This intercomparison is published in Nucl. Instr. and Meth. B [N.P. Barradas, K. Arstila, G. Battistig, M. Bianconi, N. Dytlewski, C. Jeynes, E. Kotai, G. Lulli, M. Mayer, E. Rauhala, E. Szilagyi, M. Thompson, Nucl. Instr. and Meth. B 262 (2007) 281-303] and summarised here. The codes implement all known physical effects and they are all evaluated. We demonstrate that there is agreement between codes often better than 0.1%; and also detailed agreement with real spectra, showing in particular that the SRIM 2003 stopping powers for Si are correct to 0.6% for 1.5 MeV He. For the case of heavy ion elastic recoil detection (HI-ERD) the single scattering codes performed poorly for scattered particles, although recoiled particles were calculated correctly.

  5. Results of the 1982 intercomparison (collaborative test) on J 131 in milk

    International Nuclear Information System (INIS)

    Wiechen, A.; Bundesanstalt fuer Milchforschung, Kiel

    1982-01-01

    The quality control of J 131 measurements in milk in the Federal Republik of Germany by an intercomparison performed in March 1982 showed a reasonable result. About two thirds of the laboratories engaged in this intercomparison had no trouble with their analytical tools. To improve the standard of J 131 determinations, laboratories with deviations from the true value were pointed to possible systematic errors. In the Federal Republik of Germany those methods for the determination of J 131 in milk have been successfully used which concentrate the iodine of the milk on an anion exchanger column and measure the J 131 directly by gammaspectrometry. (orig.) [de

  6. Reactor neutron activation analysis on reference materials from intercomparison runs

    International Nuclear Information System (INIS)

    Pantelica, A.; Salagean, M.

    2003-01-01

    A review of using the Instrumental Neutron Activation Analysis (INAA) technique in our laboratory to determine major, minor and trace elements in mineral and biological samples from international intercomparison runs organised by IAEA Vienna, IAEA-MEL Monaco, 'pb-anal' Kosice, INCT Warszawa and IPNT Krakow is presented. Neutron irradiation was carried out at WWR-S reactor in Bucharest (short and long irradiation) during 1982-1997 and at TRIGA reactor in Pitesti (long irradiation) during the later period. The following type of materials were analysed: soils, marine sediments, uranium phosphate ore, water sludge, copper flue dust, whey powder, yeast, cereal flour (rye and wheat), marine animal tissue (mussel, garfish and tuna fish), as well as vegetal tissue (seaweed, cabbage, spinach, alfalfa, algae, tea leaves and herbs). The following elements could be, in general, determined: Ag, As, Au, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, K, La, Lu, Mo, Na, Nd, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, W, Yb and Zn of long-lived radionuclides, as well as Al, Ca, Cl, Cu, Mg, Mn, and Ti of short-lived radionuclides. Data obtained in our laboratory for various matrix samples presented and compared with the intercomparison certified values. The intercomparison exercises offer to the participating laboratories the opportunity to test the accuracy of their analytical methods as well as to acquire valuable Reference Materials/ standards for future analytical applications. (authors)

  7. Intercomparison and analyses of the climatology of the West African monsoon in the West African monsoon modeling and evaluation project (WAMME) first model intercomparison experiment

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Yongkang; Sales, Fernando De [University of California, Los Angeles, CA (United States); Lau, W.K.M.; Schubert, Siegfried D.; Wu, Man-Li C. [NASA, Goddard Space Flight Center, Greenbelt, MD (United States); Boone, Aaron [Centre National de Recherches Meteorologiques, Meteo-France Toulouse, Toulouse (France); Feng, Jinming [University of California, Los Angeles, CA (United States); Chinese Academy of Sciences, Institute of Atmospheric Physics, Beijing (China); Dirmeyer, Paul; Guo, Zhichang [Center for Ocean-Land-Atmosphere Interactions, Calverton, MD (United States); Kim, Kyu-Myong [University of Maryland Baltimore County, Baltimore, MD (United States); Kitoh, Akio [Meteorological Research Institute, Tsukuba (Japan); Kumar, Vadlamani [National Center for Environmental Prediction, Camp Springs, MD (United States); Wyle Information Systems, Gaithersburg, MD (United States); Poccard-Leclercq, Isabelle [Universite de Bourgogne, Centre de Recherches de Climatologie UMR5210 CNRS, Dijon (France); Mahowald, Natalie [Cornell University, Ithaca, NY (United States); Moufouma-Okia, Wilfran; Rowell, David P. [Met Office Hadley Centre, Exeter (United Kingdom); Pegion, Phillip [NASA, Goddard Space Flight Center, Greenbelt, MD (United States); National Center for Environmental Prediction, Camp Springs, MD (United States); Schemm, Jae; Thiaw, Wassila M. [National Center for Environmental Prediction, Camp Springs, MD (United States); Sealy, Andrea [The Caribbean Institute for Meteorology and Hydrology, St. James (Barbados); Vintzileos, Augustin [National Center for Environmental Prediction, Camp Springs, MD (United States); Science Applications International Corporation, Camp Springs, MD (United States); Williams, Steven F. [National Center for Atmospheric Research, Boulder, CO (United States)

    2010-07-15

    This paper briefly presents the West African monsoon (WAM) modeling and evaluation project (WAMME) and evaluates WAMME general circulation models' (GCM) performances in simulating variability of WAM precipitation, surface temperature, and major circulation features at seasonal and intraseasonal scales in the first WAMME experiment. The analyses indicate that models with specified sea surface temperature generally have reasonable simulations of the pattern of spatial distribution of WAM seasonal mean precipitation and surface temperature as well as the averaged zonal wind in latitude-height cross-section and low level circulation. But there are large differences among models in simulating spatial correlation, intensity, and variance of precipitation compared with observations. Furthermore, the majority of models fail to produce proper intensities of the African Easterly Jet (AEJ) and the tropical easterly jet. AMMA Land Surface Model Intercomparison Project (ALMIP) data are used to analyze the association between simulated surface processes and the WAM and to investigate the WAM mechanism. It has been identified that the spatial distributions of surface sensible heat flux, surface temperature, and moisture convergence are closely associated with the simulated spatial distribution of precipitation; while surface latent heat flux is closely associated with the AEJ and contributes to divergence in AEJ simulation. Common empirical orthogonal functions (CEOF) analysis is applied to characterize the WAM precipitation evolution and has identified a major WAM precipitation mode and two temperature modes (Sahara mode and Sahel mode). Results indicate that the WAMME models produce reasonable temporal evolutions of major CEOF modes but have deficiencies/uncertainties in producing variances explained by major modes. Furthermore, the CEOF analysis shows that WAM precipitation evolution is closely related to the enhanced Sahara mode and the weakened Sahel mode, supporting

  8. The impact of geoengineering on vegetation in experiment G1 of the Geoengineering Model Intercomparison Project

    Science.gov (United States)

    Irvine, Peter; Glienke, Susanne; Lawrence, Mark

    2015-04-01

    Solar Radiation Management (SRM) has been proposed as a means to partly counteract global warming. The Geoengineering Model Intercomparison Project (GeoMIP) simulated the climate consequences of a number of SRM techniques, but the effects on vegetation have not yet been thoroughly studied. Here, the vegetation response to the idealized GeoMIP G1 experiment is analyzed, in which a reduction of the solar constant counterbalances the radiative effects of quadrupled atmospheric CO2 concentrations; the results from eight fully coupled earth system models (ESMs) are included. For most models and regions, changes in net primary productivity (NPP) are dominated by the increase in CO2, via the CO2 fertilization effect. As SRM will lower temperatures, in high latitudes this will reverse gains in NPP from the lifting of temperature limitations. In low latitudes this cooling relative to the 4xCO2 simulation decreases plant respiration whilst having little effect on gross primary productivity, increasing NPP. Despite reductions in precipitation in most regions in response to SRM, runoff and NPP increase in many regions including those previously highlighted as potentially being at risk of drought under SRM. This is due to simultaneous reductions in evaporation and increases in water use efficiency by plants due to higher CO2 concentrations. The relative differences between models in the vegetation response are substantially larger than the differences in their climate responses. The largest differences between models are for those with and without a nitrogen-cycle, with a much smaller CO2 fertilization effect for the former. These results suggest that until key vegetation processes are integrated into ESM predictions, the vegetation response to SRM will remain highly uncertain.

  9. Firn Model Intercomparison Experiment (FirnMICE)

    DEFF Research Database (Denmark)

    Lundin, Jessica M.D.; Stevens, C. Max; Arthern, Robert

    2017-01-01

    Evolution of cold dry snow and firn plays important roles in glaciology; however, the physical formulation of a densification law is still an active research topic. We forced eight firn-densification models and one seasonal-snow model in six different experiments by imposing step changes in tempe...

  10. The Carbon Dioxide Removal Model Intercomparison Project (CDRMIP: rationale and experimental protocol for CMIP6

    Directory of Open Access Journals (Sweden)

    D. P. Keller

    2018-03-01

    Full Text Available The recent IPCC reports state that continued anthropogenic greenhouse gas emissions are changing the climate, threatening severe, pervasive and irreversible impacts. Slow progress in emissions reduction to mitigate climate change is resulting in increased attention to what is called geoengineering, climate engineering, or climate intervention – deliberate interventions to counter climate change that seek to either modify the Earth's radiation budget or remove greenhouse gases such as CO2 from the atmosphere. When focused on CO2, the latter of these categories is called carbon dioxide removal (CDR. Future emission scenarios that stay well below 2 °C, and all emission scenarios that do not exceed 1.5 °C warming by the year 2100, require some form of CDR. At present, there is little consensus on the climate impacts and atmospheric CO2 reduction efficacy of the different types of proposed CDR. To address this need, the Carbon Dioxide Removal Model Intercomparison Project (or CDRMIP was initiated. This project brings together models of the Earth system in a common framework to explore the potential, impacts, and challenges of CDR. Here, we describe the first set of CDRMIP experiments, which are formally part of the 6th Coupled Model Intercomparison Project (CMIP6. These experiments are designed to address questions concerning CDR-induced climate reversibility, the response of the Earth system to direct atmospheric CO2 removal (direct air capture and storage, and the CDR potential and impacts of afforestation and reforestation, as well as ocean alkalinization.>

  11. Review and intercomparison of operational methods for the determination of the mixing height

    DEFF Research Database (Denmark)

    Seibert, P.; Beyrich, F.; Gryning, Sven-Erik

    2002-01-01

    The height of the atmospheric boundary layer (ABL) or the mixing height (MH) is a fundamental parameter characterising the structure of the lower troposphere. Two basic possibilities for the practical determination of the MH are its derivation from profile data (measurements or numerical model...... output) and its parameterisation using simple equations or models (which only need a few measured input values). Different methods suggested in the literature are reviewed in this paper. The most important methods have been tested on data sets from three different sites in Europe (Cabauw—NL, Payerne......—CH, Melpitz—D). Parcel and Richardson number methods applied to radiosonde profiles and the analysis of sodar and wind profiler data have been investigated. Modules for MH determination implemented in five currently used meteorological preprocessors for dispersion models have been tested, too. Parcel methods...

  12. Report on the intercomparison run IAEA-155 trace elements in whey powder

    International Nuclear Information System (INIS)

    Zeiller, E.; Strachnov, V.; Dekner, R.

    1990-11-01

    Analytical results need to be reliable, and analysts are well serviced to test their complete analytical systems, methods, instruments, personnel, data reduction, etc., on a frequent basis. Besides the use of standard reference materials, the intercomparison runs provide an excellent opportunity for the determination of accuracy. By comparing their results with results obtained by different methods of preparation and measurement, the participating laboratories have the opportunity to check their analytical performances. At the same time the IAEA's AQCS can establish the concentration of some elements for certification purposes. The participants were requested to determine as many elements as possible with emphasis on ''essential'' and ''toxic'' elements related to human health and environmental pollution in the intercomparison whey powder sample (IAEA-155) as well as in the control sample IAEA. It was expected that the results for IAEA would improve the evaluation of the intercomparison results of IAEA-155 as the concentrations of some inorganic constituents were well established in the IAEA sample. In total 69 laboratories from 24 different countries participated in this exercise. As a basis for the evaluation, 580 laboratory means were reported comprising 2699 individual results for 45 elements. For 3 additional elements information was supplied that the value was below the detection limits of the methods. Even though information and data on 48 elements were reported for IAEA-155 only 4 elements are assigned Class A and 13 elements Class B recommended values. The elements Mg, Mn, Na and P were assigned ''Class A''. But contrary to some former intercomparison exercises, this time sufficient results could be obtained to set ''Class B'' recommended values for some ''difficult to determine'' elements like Cd, Co, Cr, Hg, Ni, Pb, Se. Figs, 45 tabs

  13. The ASSET intercomparison of stratosphere and lower mesosphere humidity analyses

    Directory of Open Access Journals (Sweden)

    H. E. Thornton

    2009-02-01

    Full Text Available This paper presents results from the first detailed intercomparison of stratosphere-lower mesosphere water vapour analyses; it builds on earlier results from the EU funded framework V "Assimilation of ENVISAT Data" (ASSET project. Stratospheric water vapour plays an important role in many key atmospheric processes and therefore an improved understanding of its daily variability is desirable. With the availability of high resolution, good quality Michelson Interferometer for Passive Atmospheric Sounding (MIPAS water vapour profiles, the ability of four different atmospheric models to assimilate these data is tested. MIPAS data have been assimilated over September 2003 into the models of the European Centre for Medium Range Weather Forecasts (ECMWF, the Belgian Institute for Space and Aeronomy (BIRA-IASB, the French Service d'Aéronomie (SA-IPSL and the UK Met Office. The resultant middle atmosphere humidity analyses are compared against independent satellite data from the Halogen Occultation Experiment (HALOE, the Polar Ozone and Aerosol Measurement (POAM III and the Stratospheric Aerosol and Gas Experiment (SAGE II. The MIPAS water vapour profiles are generally well assimilated in the ECMWF, BIRA-IASB and SA systems, producing stratosphere-mesosphere water vapour fields where the main features compare favourably with the independent observations. However, the models are less capable of assimilating the MIPAS data where water vapour values are locally extreme or in regions of strong humidity gradients, such as the southern hemisphere lower stratosphere polar vortex. Differences in the analyses can be attributed to the choice of humidity control variable, how the background error covariance matrix is generated, the model resolution and its complexity, the degree of quality control of the observations and the use of observations near the model boundaries. Due to the poor performance of the Met Office analyses the results are not included in

  14. The ASSET intercomparison of stratosphere and lower mesosphere humidity analyses

    Science.gov (United States)

    Thornton, H. E.; Jackson, D. R.; Bekki, S.; Bormann, N.; Errera, Q.; Geer, A. J.; Lahoz, W. A.; Rharmili, S.

    2009-02-01

    This paper presents results from the first detailed intercomparison of stratosphere-lower mesosphere water vapour analyses; it builds on earlier results from the EU funded framework V "Assimilation of ENVISAT Data" (ASSET) project. Stratospheric water vapour plays an important role in many key atmospheric processes and therefore an improved understanding of its daily variability is desirable. With the availability of high resolution, good quality Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) water vapour profiles, the ability of four different atmospheric models to assimilate these data is tested. MIPAS data have been assimilated over September 2003 into the models of the European Centre for Medium Range Weather Forecasts (ECMWF), the Belgian Institute for Space and Aeronomy (BIRA-IASB), the French Service d'Aéronomie (SA-IPSL) and the UK Met Office. The resultant middle atmosphere humidity analyses are compared against independent satellite data from the Halogen Occultation Experiment (HALOE), the Polar Ozone and Aerosol Measurement (POAM III) and the Stratospheric Aerosol and Gas Experiment (SAGE II). The MIPAS water vapour profiles are generally well assimilated in the ECMWF, BIRA-IASB and SA systems, producing stratosphere-mesosphere water vapour fields where the main features compare favourably with the independent observations. However, the models are less capable of assimilating the MIPAS data where water vapour values are locally extreme or in regions of strong humidity gradients, such as the southern hemisphere lower stratosphere polar vortex. Differences in the analyses can be attributed to the choice of humidity control variable, how the background error covariance matrix is generated, the model resolution and its complexity, the degree of quality control of the observations and the use of observations near the model boundaries. Due to the poor performance of the Met Office analyses the results are not included in the intercomparison

  15. Intercomparison of Operational Ocean Forecasting Systems in the framework of GODAE

    Science.gov (United States)

    Hernandez, F.

    2009-04-01

    One of the main benefits of the GODAE 10-year activity is the implementation of ocean forecasting systems in several countries. In 2008, several systems are operated routinely, at global or basin scale. Among them, the BLUElink (Australia), HYCOM (USA), MOVE/MRI.COM (Japan), Mercator (France), FOAM (United Kingdom), TOPAZ (Norway) and C-NOOFS (Canada) systems offered to demonstrate their operational feasibility by performing an intercomparison exercise during a three months period (February to April 2008). The objectives were: a) to show that operational ocean forecasting systems are operated routinely in different countries, and that they can interact; b) to perform in a similar way a scientific validation aimed to assess the quality of the ocean estimates, the performance, and forecasting capabilities of each system; and c) to learn from this intercomparison exercise to increase inter-operability and collaboration in real time. The intercomparison relies on the assessment strategy developed for the EU MERSEA project, where diagnostics over the global ocean have been revisited by the GODAE contributors. This approach, based on metrics, allow for each system: a) to verify if ocean estimates are consistent with the current general knowledge of the dynamics; and b) to evaluate the accuracy of delivered products, compared to space and in-situ observations. Using the same diagnostics also allows one to intercompare the results from each system consistently. Water masses and general circulation description by the different systems are consistent with WOA05 Levitus climatology. The large scale dynamics (tropical, subtropical and subpolar gyres ) are also correctly reproduced. At short scales, benefit of high resolution systems can be evidenced on the turbulent eddy field, in particular when compared to eddy kinetic energy deduced from satellite altimetry of drifter observations. Comparisons to high resolution SST products show some discrepancies on ocean surface

  16. Intercomparison and calibration of dose calibrators used in nuclear medicine facilities

    CERN Document Server

    Costa, A M D

    2003-01-01

    The aim of this work was to establish a working standard for intercomparison and calibration of dose calibrators used in most of nuclear medicine facilities for the determination of the activity of radionuclides administered to patients in specific examinations or therapeutic procedures. A commercial dose calibrator, a set of standard radioactive sources, and syringes, vials and ampoules with radionuclide solutions used in nuclear medicine were utilized in this work. The commercial dose calibrator was calibrated for radionuclide solutions used in nuclear medicine. Simple instrument tests, such as linearity response and variation response with the source volume at a constant source activity concentration were performed. This instrument may be used as a reference system for intercomparison and calibration of other activity meters, as a method of quality control of dose calibrators utilized in nuclear medicine facilities.

  17. Results from 2010 Caliban Criticality Dosimetry Intercomparison

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G.

    2011-10-12

    The external dosimetry program participated in a criticality dosimetry intercomparison conducted at the Caliban facility in Valduc, France in 2010. Representatives from the dosimetry and instrumentation groups were present during testing which included irradiations of whole-body beta/gamma (HBGT) and neutron thermoluminescent dosimeters (TLDs), a fixed nuclear accident dosimeter (FNAD), electronic alarming dosimeters, and a humanoid phantom filled with reference man concentrations of sodium. This report reviews the testing procedures, preparations, irradiations, and presents results of the tests.

  18. Dosimetry audits and intercomparisons in radiotherapy: A Malaysian profile

    Science.gov (United States)

    M. Noor, Noramaliza; Nisbet, A.; Hussein, M.; Chu S, Sarene; Kadni, T.; Abdullah, N.; Bradley, D. A.

    2017-11-01

    Quality audits and intercomparisons are important in ensuring control of processes in any system of endeavour. Present interest is in control of dosimetry in teletherapy, there being a need to assess the extent to which there is consistent radiation dose delivery to the patient. In this study we review significant factors that impact upon radiotherapy dosimetry, focusing upon the example situation of radiotherapy delivery in Malaysia, examining existing literature in support of such efforts. A number of recommendations are made to provide for increased quality assurance and control. In addition to this study, the first level of intercomparison audit i.e. measuring beam output under reference conditions at eight selected Malaysian radiotherapy centres is checked; use being made of 9 μm core diameter Ge-doped silica fibres (Ge-9 μm). The results of Malaysian Secondary Standard Dosimetry Laboratory (SSDL) participation in the IAEA/WHO TLD postal dose audit services during the period between 2011 and 2015 will also been discussed. In conclusion, following review of the development of dosimetry audits and the conduct of one such exercise in Malaysia, it is apparent that regular periodic radiotherapy audits and intercomparison programmes should be strongly supported and implemented worldwide. The programmes to-date demonstrate these to be a good indicator of errors and of consistency between centres. A total of ei+ght beams have been checked in eight Malaysian radiotherapy centres. One out of the eight beams checked produced an unacceptable deviation; this was found to be due to unfamiliarity with the irradiation procedures. Prior to a repeat measurement, the mean ratio of measured to quoted dose was found to be 0.99 with standard deviation of 3%. Subsequent to the repeat measurement, the mean distribution was 1.00, and the standard deviation was 1.3%.

  19. Extremity ring dosimetry intercomparison in reference and workplace fields

    International Nuclear Information System (INIS)

    Ginjaume, M.; Carinou, E.; Donadille, L.; Jankowski, J.; Rimpler, A.; Sans Merce, M.; Vanhavere, F.; Denoziere, M.; Daures, J.; Bordy, J. M.; Itie, C.; Covens, P.

    2008-01-01

    An intercomparison of ring dosemeters has been organised with the aim of assessing the technical capabilities of available extremity dosemeters and focusing on their performance at clinical workplaces with potentially high extremity doses. Twenty-four services from 16 countries participated in the intercomparison. The dosemeters were exposed to reference photon ( 137 Cs) and beta ( 147 Pm, 85 Kr and 90 Sr/ 90 Y) fields together with fields representing realistic exposure situations in interventional radiology (direct and scattered radiation) and nuclear medicine ( 99m Tc and 18 F). It has been found that most dosemeters provided satisfactory measurements of H p (0.07) for photon radiation, both in reference and realistic fields. However, only four dosemeters fulfilled the established requirements for all radiation qualities. The main difficulties were found for the measurement of low-energy beta radiation. Finally, the results also showed a general under-response of detectors to 18 F, which was attributed to the difficulties of the dosimetric systems to measure the positron contribution to the dose. (authors)

  20. Field intercomparison of prevailing sonic anemometers

    Science.gov (United States)

    Mauder, Matthias; Zeeman, Matthias J.

    2018-01-01

    Three-dimensional sonic anemometers are the core component of eddy covariance systems, which are widely used for micrometeorological and ecological research. In order to characterize the measurement uncertainty of these instruments we present and analyse the results from a field intercomparison experiment of six commonly used sonic anemometer models from four major manufacturers. These models include Campbell CSAT3, Gill HS-50 and R3, METEK uSonic-3 Omni, R. M. Young 81000 and 81000RE. The experiment was conducted over a meadow at the TERENO/ICOS site DE-Fen in southern Germany over a period of 16 days in June of 2016 as part of the ScaleX campaign. The measurement height was 3 m for all sensors, which were separated by 9 m from each other, each on its own tripod, in order to limit contamination of the turbulence measurements by adjacent structures as much as possible. Moreover, the high-frequency data from all instruments were treated with the same post-processing algorithm. In this study, we compare the results for various turbulence statistics, which include mean horizontal wind speed, standard deviations of vertical wind velocity and sonic temperature, friction velocity, and the buoyancy flux. Quantitative measures of uncertainty, such as bias and comparability, are derived from these results. We find that biases are generally very small for all sensors and all computed variables, except for the sonic temperature measurements of the two Gill sonic anemometers (HS and R3), confirming a known transducer-temperature dependence of the sonic temperature measurement. The best overall agreement between the different instruments was found for the mean wind speed and the buoyancy flux.

  1. Intercomparison of the air kerma and absorbed dose to water therapy calibrations provided by NRPA and CPRH SSDLs

    International Nuclear Information System (INIS)

    Morales, J.A.; Campa, R.; Bjerke, H.; Jensen, H.

    2001-01-01

    in February 2000. The comparison comprised the calibration of a field class ionization chamber in terms of air kerma at low and medium-energy kilo voltage X-ray qualities and 60 Co as well as the calibration in terms of absorbed dose to water (at 60 Co radiation quality). The intercomparison represents for the CPHR the validation of the newly implemented calibration service at X-ray qualities. The NRPA SSDL has in recent years participated in EUROMET and IAEA dosimetry intercomparisons with satisfactory results. Experiences derived from the present comparison are discussed and summarized in this report. Recommendations to the SSDL members of the IAEA/WHO Network in order to encourage regional cooperation by organizing similar intercomparison exercises as well as the possibility for the IAEA to extend the present audit services, to cover certain X-ray beam qualities, are also commented

  2. International whole body counter intercomparison based on BOMAB phantom simulating 4 years old child

    International Nuclear Information System (INIS)

    Battisti, P.; Tarroni, G.

    1995-11-01

    In April 1993 a whole body counter intercomparison campaign, The 1993 Intercomparison/Intercalibration, started. The campaign has been organized by The Canadian National Reference Centre for In-Vivo Monitoring of Radiation Protection Bureau, Health Canada and The United States Department of Energy and it was based on measurements on a BOMAB type phantom simulating a 4 years old child. The phantom was filled with radioactive tissue substitute resin and an unknown quantity of radioactivity. Each facility was asked to determine the identity and amount of the radionuclide(s), knowing that the specific activity in the 10 BOMAB's sections was the same. Each facility was also asked to calculate the minimum detectable activity of all the radionuclides detected in the phantom. 35 Facilities from 20 different Countries took part in the initiative. The Institute for Radiation Protection of the Environment Department of ENEA (ENEA AMB IRP) represented Italy. Intercomparison results supplied by ENEA AMB IRP as radionuclides identification, activity data and associated precision, minimum detectable activity levels, can be considered satisfactory and comparable with results supplied by similar-facilities

  3. Regional inter-comparison of measurements of personal dose equivalent Hp(10) using photon beams

    International Nuclear Information System (INIS)

    Bero, M.; Zahili, M.; Kharita, M.H.

    2012-11-01

    The overall objective is to verify performance and to improve the Individual Monitoring services (IMS). This can be achieved with the following specific objectives of the intercomparison:1. To assess the capabilities of the dosimetry services to measure the quantity H p (10) in photon (gamma and x-ray) fields. 2. To help the participating Member States in achieving sufficiently accurate dosimetry service and, if necessary, 3. To provide guidelines for improvements and not simply a test of the performance of the existing dosimetric service. Actually a significant improvement has been achieved by the participants in the accuracy of evaluating personal dose equivalent from 15% in the first phase to 5% in the second phase. Some participants used the results of the inter-comparison to verify the calibration and to improve their dosimetric procedures, but from the results it was clear that some participants need to a technical support especially in calibration and using their measuring system in the field of personal monitoring. The conclusion contains advises, solutions, propositions and evaluation for all situations which noticed during the intercomparison. (authors)

  4. The effects of intervening interference on working memory for sound location as a function of inter-comparison interval.

    Science.gov (United States)

    Ries, Dennis T; Hamilton, Traci R; Grossmann, Aurora J

    2010-09-01

    This study examined the effects of inter-comparison interval duration and intervening interference on auditory working memory (AWM) for auditory location. Interaural phase differences were used to produce localization cues for tonal stimuli and the difference limen for interaural phase difference (DL-IPD) specified as the equivalent angle of incidence between two sound sources was measured in five different conditions. These conditions consisted of three different inter-comparison intervals [300 ms (short), 5000 ms (medium), and 15,000 ms (long)], the medium and long of which were presented both in the presence and absence of intervening tones. The presence of intervening stimuli within the medium and long inter-comparison intervals produced a significant increase in the DL-IPD compared to the medium and long inter-comparison intervals condition without intervening tones. The result obtained in the condition with a short inter-comparison interval was roughly equivalent to that obtained for the medium inter-comparison interval without intervening tones. These results suggest that the ability to retain information about the location of a sound within AWM decays slowly; however, the presence of intervening sounds readily disrupts the retention process. Overall, the results suggest that the temporal decay of information within AWM regarding the location of a sound from a listener's environment is so gradual that it can be maintained in trace memory for tens of seconds in the absence of intervening acoustic signals. Conversely, the presence of intervening sounds within the retention interval may facilitate the use of context memory, even for shorter retention intervals, resulting in a less detailed, but relevant representation of the location that is resistant to further degradation. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  5. EURADOS intercomparisons in external radiation dosimetry: similarities and differences among exercises for whole-body photon, whole-body neutron, extremity, eye-lens and passive area dosemeters

    International Nuclear Information System (INIS)

    Romero, Ana M.; Grimbergen, Tom; McWhan, Andrew; Stadtmann, Hannes; Fantuzzi, Elena; Clairand, Isabelle; Neumaier, Stefan; Dombrowski, Harald; Figel, Markus

    2016-01-01

    The European Radiation Dosimetry Group (EURADOS) has been organising dosimetry intercomparisons for many years in response to an identified requirement from individual monitoring services (IMS) for independent performance tests for dosimetry systems. The participation in intercomparisons gives IMS the opportunity to show compliance with their own quality management system, compare results with other participants and develop plans for improving their dosimetry systems. In response to growing demand, EURADOS has increased the number of intercomparisons for external radiation dosimetry. Most of these fit into the programme of self-financing intercomparisons for dosemeters routinely used by IMS. This programme is being coordinated by EURADOS working group 2 (WG2). Up to now, this programme has included four intercomparisons for whole-body dosemeters in photon fields, one for extremity dosemeters in photon and beta fields, and one for whole-body dosemeters in neutron fields. Other EURADOS working groups have organised additional intercomparisons including events in 2014 for eye-lens dosemeters and passive area dosemeters for environmental monitoring. In this paper, the organisation and achievements of these intercomparisons are compared in detail focusing on the similarities and differences in their execution. (authors)

  6. Intercomparison run for uranium and tritium determination in urine samples, organised by Nuclear Regulatory Authority, Argentina

    International Nuclear Information System (INIS)

    Serdeiro, Nelida H.; Equillor, Hugo E.; Bonino, Nestor O.

    2003-01-01

    The Nuclear Regulatory Authority (ARN), Argentina, has carried out an intercomparison run for tritium and uranium determination in urine, in November 2002. The aim of this exercise was to assess the performance of the laboratories that usually inform these radionuclides and to provide technical support in order to have an appropriate occupational monitoring in vitro. In the present work, the results of the intercomparison and the assessment of each laboratory are published. (author)

  7. Intercomparison run for uranium and tritium determination in urine samples, organised by Nuclear Regulatory Authority, Argentina

    CERN Document Server

    Serdeiro, N H; Equillor, H E

    2003-01-01

    The Nuclear Regulatory Authority (ARN), Argentina, has carried out an intercomparison run for tritium and uranium determination in urine, in November 2002. The aim of this exercise was to assess the performance of the laboratories that usually inform these radionuclides and to provide technical support in order to have an appropriate occupational monitoring in vitro. In the present work, the results of the intercomparison and the assessment of each laboratory are published.

  8. Results of the 2001 NRPB intercomparison of passive radon detectors

    CERN Document Server

    Howarth, C B

    2002-01-01

    As in previous years, an intercomparison of passive radon detectors was held at NRPB in 2001. Forty-seven laboratories submitted 62 sets of passive detectors to this intercomparison. The exercise included three exposures to radon and its decay products at different equilibrium factors. An additional exposure at the CERN - EU high Energy Reference Facility (CERF) to a simulated cosmic ray spectrum was also offered to participants. After exposure, the detectors were returned to their originating laboratories for assessment. Participants reported the estimated exposure for each detector before they were notified of the exposures given to the detectors. The results obtained by participating laboratories were classified according to the spread of results from detectors exposed together and by the difference between the mean result of each group and the actual exposure given. Thirty-five percent of the laboratories achieved the highest classification for accuracy, while 9% were in the lowest category. The proportio...

  9. Report on the intercomparison run IAEA-306 radionuclides in Baltic Sea sediment

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1989-10-01

    The results of an intercomparison exercise on a Baltic Sea sediment sample, coded as IAEA-306, designed for the determination of artificial and natural radionuclide levels, are reported. This sample was collected in the fall 1986. It was anticipated that the concentrations of the artificial radionuclides in this sediment would be higher than the environmental levels usually found and, therefore, would constitute an excellent intercomparison sample. The data from 84 laboratories representing 34 countries have been evaluated. The most frequently measured radionuclides are: 90 Sr, 125 Sb, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K, 210 Pb- 210 Po, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U and 238 U. 6 refs, 13 tabs

  10. International intercomparison of dose measurements using EPR spectrometry of tooth enamel

    International Nuclear Information System (INIS)

    Wieser, A.; Chumak, V.; Pasalskaya, L.; Pavlenko, J.; Sholom, S.; Bailiff, I.; Baran, N.; Bougai, A.; Kolesnik, S.; Maksimenko, V.; Brik, A.; Matyash, M.; Scherbina, O.; Dubovsky, S.; Kirillov, V.; Minenko, V.; Finin, V.; Haskell, E.; Hayes, R.; Kenner, G.; Ivannikov, A.; Skvortsov, V.; Stepanenko, V.; Liidja, G.; Lippmaa, E.; Past, J.; Puskar, J.; Meijer, A.; Radchuk, V.; Vaher, Ue.

    1996-01-01

    Electron paramagnetic resonance (EPR) dosimetry with teeth is the only solid state dosimetry method that allows for direct measurement of the individual dose. It is considered to be a very promising tool for retrospective individual dosimetry after accidental radioactive releases. It will help to make a reliable assessment of the radiation risk. A number of laboratories are engaged in retrospective EPR dosimetry with teeth. There is consequently a need to develop a programme of intercalibration and intercomparison to check whether the results produced by different laboratories are either consistent or accurate. The Commission of the European Communities has initiated the project ECP10 entitled, Retrospective Dosimetry and Dose reconstruction. Within the joint Eu/CIS project the 1st International Intercomparison of EPR Dosimetry with Teeth' was started in 1994. Nine research laboratories were involved from Germany, Russia, Belarus, Ukraine, Estonia and USA

  11. EURADOS intercomparison on measurements and Monte Carlo modelling for the assessment of Americium in a USTUR leg phantom

    International Nuclear Information System (INIS)

    Lopez, M. A.; Broggio, D.; Capello, K.; Cardenas-Mendez, E.; El-Faramawy, N.; Franck, D.; James, A. C.; Kramer, G. H.; Lacerenza, G.; Lynch, T. P.; Navarro, J. F.; Navarro, T.; Perez, B.; Ruehm, W.; Tolmachev, S. Y.; Weitzenegger, E.

    2011-01-01

    A collaboration of the EURADOS working group on 'Internal Dosimetry' and the United States Transuranium and Uranium Registries (USTUR) has taken place to carry out an intercomparison on measurements and Monte Carlo modelling determining americium deposited in the bone of a USTUR leg phantom. Preliminary results and conclusions of this intercomparison exercise are presented here. (authors)

  12. Report on intercomparison exercise SR-74 determination of impurities in U3O8

    International Nuclear Information System (INIS)

    Doubek, N.; Deron, S.

    1987-06-01

    The report presents results of a laboratory intercomparison of the determination of impurities in U 3 O 8 sample organized by the IAEA. Seven laboratories of six countries, sent their results regarding 31 elements. The evaluation was based on 121 laboratory means. The majority of the results were obtained by emission spectroscopy and by flame atomic absorption techniques. As a result of this intercomparison, recommended certification values can be assigned for the concentration of Cr, Cu and Mg. Information values can be provided for an additional twelve elements (Al, B, Co, Fe, Mn, Mo, Ni, P, Pb, Sn, V, and Zn)

  13. Results of the IAEA/RCA personal dosemeter intercomparison in the Asian and Pacific region

    International Nuclear Information System (INIS)

    Murakami, H.; Minami, K.; Griffith, R.V.

    1994-01-01

    In 1988, the International Atomic Energy Agency started the Regional Co-operative Agreement project for strengthening the radiation protection infrastructure in the Asian and Pacific region. One component of the initial programme was a regional personal dosimetry intercomparison, which was subsequently conducted in three phases over three years during the period 1990 to 1992. Seventeen organisations of all 14 member states participated in the programmes. Irradiations and data compilation were conducted by the Japan Atomic Energy Research Institute. This paper describes the results of the intercomparison programmes and discusses some features and personal dosimetry problems in the RCA member states. (author)

  14. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  15. Biological dosimetry after criticality accidents. Intercomparison exercise in the Silene Reactor - France; Dosimetria biologica en accidentes de criticidad. Ejercicio de intercomparacion en el Reactor Silene - Francia

    Energy Technology Data Exchange (ETDEWEB)

    Di Giorgio, Marina; Vallerga, Maria B; Taja, Maria R [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); arn gov ar, E-mail: mdigiorg@cae

    2004-07-01

    The Institute of Radiation Protection and Nuclear Safety Institute (IRSN) organized an international biological dosimetry intercomparison, at the SILENE experimental reactor (Valduc, France), simulating different criticality scenarios: bare source 4 Gy, lead shield source 1 and 2 Gy and gamma pure {sup 60}Co source 2 Gy. Fifteen laboratories were involved in this exercise, including the Argentine Biological Dosimetry Laboratory. The purposes of the intercomparison were: 1) To compare the unstable chromosome aberration (UCA) frequency observed by the different laboratories; and 2) To compare the dose estimation for gamma rays and neutrons. The objects of the present work were: I) To compare the mean frequency of UCA observed by the Argentine laboratory with the mean frequency observed by the participant laboratories as a whole. II) To compare the dose estimates performed by the Argentine lab with those estimated by the other laboratories involved in the second stage of the intercomparison. Overall, the mean frequencies of UCA and the correspondent 95% confidence limits obtained by the Argentine lab were consistent with the results obtained by the laboratories as a whole. For the gamma pure scenario, smaller variations were observed among laboratories in terms of dose (CV=18,2%) than in terms of frequency (CV=30,1%). For the mixed field scenarios, only four laboratories, including the Argentine lab, estimated gamma and neutron components of the total dose and just two (Argentine lab and lab 12) were in agreement with the given physical doses. The 1 Gy experiment presented lesser variations both in terms of frequency and dose than the other two scenarios. For the 4 and 2 Gy experiments, variations in neutron dose were more significant than variations in gamma dose, related to the magnitude of the dose. The results suggest that intercomparison exercises jointly with the accreditation of biological dosimetry by cytogenetic service laboratories, in compliance with ISO

  16. Intercomparison of Terrestrial Laser Scanning Instruments for Assessing Forested Ecosystems: A Brisbane Field Experiment

    Science.gov (United States)

    Armston, J.; Newnham, G.; Strahler, A. H.; Schaaf, C.; Danson, M.; Gaulton, R.; Zhang, Z.; Disney, M.; Sparrow, B.; Phinn, S. R.; Schaefer, M.; Burt, A.; Counter, S.; Erb, A.; Goodwin, N.; Hancock, S.; Howe, G.; Johansen, K.; Li, Z.; Lollback, G.; Martel, J.; Muir, J.; Paynter, I.; Saenz, E.; Scarth, P.; Tindall, D.; Walker, L.; Witte, C.; Woodgate, W.; Wu, S.

    2013-12-01

    During 28th July - 3rd August, 2013, an international group of researchers brought five terrestrial laser scanners (TLS) to long-term monitoring plots in three eucalyptus-dominated woodland sites near Brisbane, Queensland, Australia, to acquire scans at common locations for calibration and intercomparison.They included: DWEL - a dual-wavelength full-waveform laser scanner (Boston U., U. Massachusetts Lowell, U. Massachusetts Boston, USA) SALCA - a dual-wavelength full-waveform laser scanner (U. Salford, UK) CBL - a canopy biomass lidar, a small ultraportable low-cost multiple discrete return scanner (U. Massachusetts Boston, USA) Riegl VZ400 - a survey-grade commercial waveform scanner (Queensland Government and TERN, U. Queensland, Australia) FARO Focus 3D - a lightweight commercial phase-shift ranging laser scanner (U. Southern Queensland) Two plots were scanned at Karawatha Forest Park, a Terrestrial Ecosystem Research Network (TERN) Supersite, and one plot at D'Aguilar National Park. At each 50 x 100 m plot, a center scan point was surrounded by four scan points located 25 m away in a cross pattern allowing for 3-D reconstructions of scan sites in the form of point clouds. At several center points, multiple instrument configurations (i.e. different beam divergence, angular resolution, pulse rate) were acquired to test the impact of instrument specifications on separation of woody and non-woody materials and estimation of vegetation structure parameters. Three-dimensional Photopoint photographic panoramas were also acquired, providing reconstructions of stems in the form of point clouds using photogrammetric correlation methods. Calibrated reflectance targets were also scanned to compare instrument geometric and radiometric performance. Ancillary data included hemispherical photos, TRAC LAI/clumping measurements, spectra of leaves, bark, litter, and other target components. Wet and dry leaf weights determined water content. Planned intercomparison topics and

  17. Results of the argentinian intercomparison on internal dosimetry 2014. Measurement of thyroid burden

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the capability to perform direct measurements of “1”3”1I thyroid burden and the expertise in the interpretation of these data for dose assessment. To that aim, in 2014 the National Intercomparison Exercise was organized and coordinated by the Internal Dosimetry Laboratory of the Autoridad Regulatoria Nuclear (ARN) of Argentina. The exercise counted with the participation of six internal dosimetry services: nuclear power plants (NA-SA CNA and NA-SA CNE), CNEA Atomic Centres: Bariloche (CAB) and Ezeiza (CAE), Roffo Institute (UBA – CNEA) and ARN. This report shows a complete analysis of the participant’s results in this exercise. (authors) [es

  18. Laboratory Experiments and Instrument Intercomparison Studies of Carbonaceous Aerosol Particles

    Energy Technology Data Exchange (ETDEWEB)

    Davidovits, Paul [Boston College, Chestnut Hill, MA (United States)

    2015-10-20

    Aerosols containing black carbon (and some specific types of organic particulate matter) directly absorb incoming light, heating the atmosphere. In addition, all aerosol particles backscatter solar light, leading to a net-cooling effect. Indirect effects involve hydrophilic aerosols, which serve as cloud condensation nuclei (CCN) that affect cloud cover and cloud stability, impacting both atmospheric radiation balance and precipitation patterns. At night, all clouds produce local warming, but overall clouds exert a net-cooling effect on the Earth. The effect of aerosol radiative forcing on climate may be as large as that of the greenhouse gases, but predominantly opposite in sign and much more uncertain. The uncertainties in the representation of aerosol interactions in climate models makes it problematic to use model projections to guide energy policy. The objective of our program is to reduce the uncertainties in the aerosol radiative forcing in the two areas highlighted in the ASR Science and Program Plan. That is, (1) addressing the direct effect by correlating particle chemistry and morphology with particle optical properties (i.e. absorption, scattering, extinction), and (2) addressing the indirect effect by correlating particle hygroscopicity and CCN activity with particle size, chemistry, and morphology. In this connection we are systematically studying particle formation, oxidation, and the effects of particle coating. The work is specifically focused on carbonaceous particles where the uncertainties in the climate relevant properties are the highest. The ongoing work consists of laboratory experiments and related instrument inter-comparison studies both coordinated with field and modeling studies, with the aim of providing reliable data to represent aerosol processes in climate models. The work is performed in the aerosol laboratory at Boston College. At the center of our laboratory setup are two main sources for the production of aerosol particles: (a

  19. The Agricultural Model Intercomparison and Improvement Project (AgMIP): Overview and Progress

    Science.gov (United States)

    Rosenzweig, C.; Hatfield, J.; Jones, J. W.; Ruane, A. C.

    2012-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is an international effort to assess the state of global agricultural modeling and to understand climate impacts on the agricultural sector. AgMIP connects the climate science, crop modeling, and agricultural economic modeling communities to generate probabilistic projections of current and future climate impacts. The goals of AgMIP are to improve substantially the characterization of risk of hunger and world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. This presentation will describe the general approach of AgMIP and highlight its findings and activities. AgMIP crop model intercomparisons have been established for wheat (27 models participating), maize (25 models), and rice (15+ models), and are being established for sugarcane, soybean, sorghum/millet, and peanut. In coordination with these pilots, methodologies to utilize weather generators and downscaled climate simulations for agricultural applications are under development. An AgMIP global agricultural economics model intercomparison with participation of 11 international groups is ongoing, and a number of global biophysical models are currently being evaluated for future climate impacts on agricultural lands both as part of the Inter-Sectoral Impact Model Intercomparison Project (ISI-MIP) and for contribution to the IPCC Fifth Assessment Report (AR5). AgMIP is also organizing regional research efforts, and has already held workshops in South America, Sub-Saharan Africa, South Asia, Europe, and North America. Outcomes from these meetings have informed AgMIP activities, and 10 research teams from Sub-Saharan Africa and South Asia have been selected for project funding. Additional activities are planned for Australia and East Asia. As the AgMIP research community continues to work towards its goals, three key cross-cutting scientific challenges have emerged and are being

  20. Intercomparison of SO2 camera systems for imaging volcanic gas plumes

    Science.gov (United States)

    Kern, Christoph; Lübcke, Peter; Bobrowski, Nicole; Campion, Robin; Mori, Toshiya; Smekens, Jean-François; Stebel, Kerstin; Tamburello, Giancarlo; Burton, Mike; Platt, Ulrich; Prata, Fred

    2015-07-01

    SO2 camera systems are increasingly being used to image volcanic gas plumes. The ability to derive SO2 emission rates directly from the acquired imagery at high time resolution allows volcanic process studies that incorporate other high time-resolution datasets. Though the general principles behind the SO2 camera have remained the same for a number of years, recent advances in CCD technology and an improved understanding of the physics behind the measurements have driven a continuous evolution of the camera systems. Here we present an intercomparison of seven different SO2 cameras. In the first part of the experiment, the various technical designs are compared and the advantages and drawbacks of individual design options are considered. Though the ideal design was found to be dependent on the specific application, a number of general recommendations are made. Next, a time series of images recorded by all instruments at Stromboli Volcano (Italy) is compared. All instruments were easily able to capture SO2 clouds emitted from the summit vents. Quantitative comparison of the SO2 load in an individual cloud yielded an intra-instrument precision of about 12%. From the imagery, emission rates were then derived according to each group's standard retrieval process. A daily average SO2 emission rate of 61 ± 10 t/d was calculated. Due to differences in spatial integration methods and plume velocity determination, the time-dependent progression of SO2 emissions varied significantly among the individual systems. However, integration over distinct degassing events yielded comparable SO2 masses. Based on the intercomparison data, we find an approximate 1-sigma precision of 20% for the emission rates derived from the various SO2 cameras. Though it may still be improved in the future, this is currently within the typical accuracy of the measurement and is considered sufficient for most applications.

  1. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoring stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed

  2. Evaluation of Brazilian intercomparison program data from 1991 to 1995 of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Vianna, Maria Elizabeth Couto M.; Tauhata, Luiz; Oliveira, Antonio Eduardo de; Oliveira, Josue Peter de; Clain, Almir Faria; Ferreira, Ana Cristina M.

    1998-01-01

    Historical radioanalytical data from the Institute of Radiation Protection and Dosimetry (IRD) national intercomparison program from 1991 to 1995 were analyzed to evaluate the performance of sixteen Brazilian laboratories in radionuclide analyses in environmental samples. Data are comprised of measurements of radionuclides in 435 spiked environmental samples distributed in fifteen intercomparison runs comprised of 955 analyses. The general and specific radionuclide performances of the participating laboratories were evaluated relative to the reference value. Data analysis encourages improvements in beta emitter measurements

  3. Intercomparison of IAEA airborne particulate matter reference material. Appendix 19

    International Nuclear Information System (INIS)

    Landsberger, Sheldon; Wu, De; Vermette, Stephen; Cizek, William

    1995-01-01

    Fifty air filters with fine and coarse fractions were prepared from NIST 2710 contaminated soil. Eighteen pairs were made and sent to seventeen laboratories of the CRP program on Applied Research on Air Pollution Using Nuclear-Related Analytical Techniques for elemental determination. The results of this intercomparison are discussed in this paper. (author)

  4. Ice nucleating particles measured during the laboratory and field intercomparisons FIN-2 and FIN-3 by the diffusion chamber FRIDGE

    Science.gov (United States)

    Weber, Daniel; Schrod, Jann; Curtius, Joachim; Haunold, Werner; Thomson, Erik; Bingemer, Heinz

    2016-04-01

    The measurement of atmospheric ice nucleating particles (INP) is still challenging. In the absence of easily applicable INP standards the intercomparison of different methods during collaborative laboratory and field workshops is a valuable tool that can shine light on the performance of individual methods for the measurement of INP [1]. FIN-2 was conducted in March 2015 at the AIDA facility in Karlsruhe as an intercomparison of mobile instruments for measuring INP [2]. FIN-3 was a field campaign at the Desert Research Institutes Storm Peak Laboratory in Colorado in September 2015 [3]. The FRankfurt Ice nucleation Deposition freezinG Experiment (FRIDGE) participated in both experiments. FRIDGE measures ice nucleating particles by electrostatic precipitation of aerosol particles onto Si-wafers in a collection unit, followed by activation, growth, and optical detection of ice crystals on the substrate in an isostatic diffusion chamber [4,5]. We will present and discuss results of our measurements of deposition/condensation INP and of immersion INP with FRIDGE during FIN-2 and FIN-3. Acknowledgements: The valuable contributions of the FIN organizers and their institutions, and of the FIN Workshop Science team are gratefully acknowledged. Our work was supported by Deutsche Forschungsgemeinschaft (DFG) under the Research Unit FOR 1525 (INUIT) and the EU FP7-ENV- 2013 BACCHUS project under Grant Agreement 603445.

  5. Stable atmospheric boundary-layer experiment in Spain (SABLES 98): A report

    DEFF Research Database (Denmark)

    Cuxart, J.; Yague, C.; Morales, G.

    2000-01-01

    boundary layer (SBL). Instrumentation deployed on two meteorological masts (of heights 10 m and 100 m) included five sonic anemometers, 15 thermocouples, five cup anemometers and three propeller anemometers, humidity sensors and radiometers. A Sensitron mini-sodar and a tethered balloon were also operated...

  6. Intercomparison and validation of computer codes for thermalhydraulic safety analysis of heavy water reactors

    International Nuclear Information System (INIS)

    2004-08-01

    Activities within the frame of the IAEA's Technical Working Group on Advanced Technologies for HWRs (TWG-HWR) are conducted in a project within the IAEA's subprogramme on nuclear power reactor technology development. The objective of the activities on HWRs is to foster, within the frame of the TWG-HWR, information exchange and co-operative research on technology development for current and future HWRs, with an emphasis on safety, economics and fuel resource sustainability. One of the activities recommended by the TWG-HWR was an international standard problem exercise entitled: Intercomparison and validation of computer codes for thermalhydraulics safety analyses. Intercomparison and validation of computer codes used in different countries for thermalhydraulics safety analyses will enhance the confidence in the predictions made by these codes. However, the intercomparison and validation exercise needs a set of reliable experimental data. The RD-14M Large-Loss Of Coolant Accident (LOCA) test B9401 simulating HWR LOCA behaviour that was conducted by Atomic Energy of Canada Ltd (AECL) was selected for this validation project. This report provides a comparison of the results obtained from six participating countries, utilizing four different computer codes. General conclusions are reached and recommendations made

  7. Intercomparison of radiation dosimeters for individual monitoring

    International Nuclear Information System (INIS)

    1993-05-01

    The Co-ordinated Research Programme on Intercomparison for Individual Monitoring was established to provide participants with an opportunity to assess (1) their ability to measure external photon radiation fields and (2) the potential impact of introduction of the new operational quantities on their dosimetry programmes. Twenty-four laboratories from 18 IAEA Member States and three international organizations, including the IAEA, participated. The results of phase II of the CRP are presented in this document, which includes a compilation of the presentations and conclusions from the meeting. Refs, figs and tabs

  8. Quality audit of dosimetry in radiotherapy centers using postal dose TLD intercomparison in India

    International Nuclear Information System (INIS)

    Ramanathan, G.; Kadam, V.D.; Vinatha, S.P.; Soman, A.T.; Vijayam, M.; Shaha, V.V.; Abani, M.C.

    2001-01-01

    The national quality audit of dosimetry in radiation therapy centers using mailed TLDs is being carried out by RSS/ASSD of BARC since 1976, in collaboration with IAEA/WHO for India and neighbouring countries such as Mayanmar, Sri Lanka and Nepal. The importance of the programme comes from the fact that consistent, high accuracy ( 60 Co machines ∼35 linear accelerators are being covered by the programme. This paper brings out the materials and methods used in the intercomparison. The results of intercomparison are analyzed to find the steps to improve the performance in quality audit of those centers whose results are outside the limit of acceptable deviation

  9. Nuclear accident dosimetry measurements at the fourth IAEA intercomparison, Harwell, United Kingdom, April 1975

    International Nuclear Information System (INIS)

    Majborn, B.

    1975-11-01

    During the fourth IAEA intercomparison at Harwell, teams from several countries compared their systems for assessing doses in criticality accidents. The dosimeters were exposed to mixed pulses of neutron and gamma radiation produced by the VIPER reactor at AWRE, Aldermaston. Risoe participated in this intercomparison with the routine personnel dosimeters employed in 'criticality areas' at Risoe. These include the UKAEA criticality dosimeter for the measurement of neutron doses and the Risoe TLD badge for the measurement of gamma doses. The final results of the Risoe measurements are presented in this report in a form designed for ease of comparison with results of other pparticipants. (author)

  10. SimilarityExplorer: A visual inter-comparison tool for multifaceted climate data

    Science.gov (United States)

    J. Poco; A. Dasgupta; Y. Wei; W. Hargrove; C. Schwalm; R. Cook; E. Bertini; C. Silva

    2014-01-01

    Inter-comparison and similarity analysis to gauge consensus among multiple simulation models is a critical visualization problem for understanding climate change patterns. Climate models, specifically, Terrestrial Biosphere Models (TBM) represent time and space variable ecosystem processes, for example, simulations of photosynthesis and respiration, using algorithms...

  11. Acid aerosol measurement method intercomparisons: An outdoor smog chamber study

    International Nuclear Information System (INIS)

    Ellestad, T.G.; Barnes, H.M.; Kamens, R.M.; McDow, S.R.; Sickles, J.E. II; Hodson, L.L.; Waldman, J.M.; Randtke, S.J.; Lane, D.D.; Springston, S.R.; Koutrakis, P.; Thurston, G.D.

    1991-01-01

    A workshop on the measurement of acid aerosols indicated that the sampling methods in use had not been intercompared. Following two laboratory pilot studies, EPA sponsored tests in an outdoor smog chamber with a variety of test aerosols, including sulfuric acid only, photochemical smog with added sulfuric acid, photo-chemical smog with added sulfuric acid and dust, and dust followed by photochemical smog with added sulfuric acid. Two experiments of each type were conducted. Six groups, several of which were active in ambient acid aerosol measurements, participated by operating duplicate samplers for each experiment. Five groups employed a similar method, in which ammonia is removed from the sample stream by diffusion, particles are removed by Teflon filter, and hydrogen ion on the Teflon filter is determined by pH electrode. However, differences existed in the method's implementation among groups in physical design, flow rate, procedures, and analysis. The sixth group's method did not use a diffusion denuder for ammonia and had several other important differences. Besides hydrogen ion, seven other species were reported by most of the groups, including particle phase sulfate, ammonium, and nitrate, and gas phase sulfur dioxide, ammonia, nitric acid, and nitrous acid. Results of the inter-comparison will be presented

  12. BRDF Characterization and Calibration Inter-Comparison between Terra MODIS, Aqua MODIS, and S-NPP VIIRS

    Science.gov (United States)

    Chang, Tiejun; Xiong, Xiaoxiong (Jack); Angal, Amit; Wu, Aisheng

    2016-01-01

    The inter-comparison of reflective solar bands (RSB) between Terra MODIS, Aqua MODIS, and SNPP VIIRS is very important for assessment of each instrument's calibration and to identify calibration improvements. One of the limitations of using their ground observations for the assessment is a lack of the simultaneous nadir overpasses (SNOs) over selected pseudo-invariant targets. In addition, their measurements over a selected Earth view target have significant difference in solar and view angles, and these differences magnify the effects of Bidirectional Reflectance Distribution Function (BRDF). In this work, an inter-comparison technique using a semi-empirical BRDF model is developed for reflectance correction. BRDF characterization requires a broad coverage of solar and view angles in the measurements over selected pseudo-invariant targets. Reflectance measurements over Libya 1, 2, and 4 desert sites from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for the calibration difference between the two instruments. The BRDF coefficients for three desert sites for MODIS bands 1 to 9 are derived and the wavelength dependencies are presented. The analysis and inter-comparison are for MODIS bands 1 to 9 and VIIRS moderate resolution radiometric bands (M bands) M1, M2, M4, M5, M7, M8, M10 and imaging bands (I bands) I1-I3. Results show that the ratios from different sites are in good agreement. The ratios between Terra and Aqua MODIS from year 2003 to 2014 are presented. The inter-comparison between MODIS and VIIRS are analyzed for year 2014.

  13. Quality control for radionuclide determinations in the Saxon state laboratories for environmental radioactivity by intercomparison and comparative measurements

    International Nuclear Information System (INIS)

    Knobus, B.

    2001-01-01

    Quality control for radionuclide analysis is necessary and essential for the quality assurance of the measuring results executing the measuring programmes of surveillance of the radioactivity in the environment and from installations. Acts, ordinances and guidelines require the participation in intercomparisons for authorized institutions detecting the demanded quality of measurements (e.g. trueness, reproducibility) for Federal Authorities. These are mainly those intercomparisons which are prepared, practised and evaluated by the federal laboratories. Comparative measurements are generally organized and executed by the state laboratory itself with a few participants for special measuring tasks. In this paper are described and discussed extend and special results of those intercomparisons and comparative measurements of the Saxon state laboratories for environmental radioactivity from 1992 until 2000. If necessary, there are following improvements for quality assurance. (orig.) [de

  14. Nineteenth nuclear accident dosimetry intercomparison study, August 9-13, 1982

    International Nuclear Information System (INIS)

    Greene, R.T.; Sims, C.C.; Swaja, R.E.

    1983-11-01

    The Nineteenth Nuclear Accident Dosimetry Intercomparison Study was held August 9 to 13, 1982, at the Oak Ridge National Laboratory using the Health Physics Research Reactor operated in the pulse mode to simulate nuclear criticality accidents. Participants from eight organizations measured neutron and gamma doses at air stations and on phantoms for three different shielding conditions. Measured results were compared to nuclear industry guidelines for criticality accident dosimeters which suggest accuracies of +-25% for neutron dose and +-20% for gamma dose. Seventy-two percent of the neutron dose measurements using foil activation, sodium activation, hair sulfur activation, and thermoluminescent methods met the guidelines while less than 40% of the gamma dose measurements were within +-20% of reference values. The softest neutron energy spectrum (also lowest neutron/gamma dose ratio) provided the most difficulty in measuring neutron and gamma doses. Results of this study indicate the need for continued intercomparison and testing of nuclear accident dosimetry systems and for training of evaluating personnel. 14 references, 7 figures, 16 tables

  15. International codes and model intercomparison for intermediate energy activation yields

    International Nuclear Information System (INIS)

    Rolf, M.; Nagel, P.

    1997-01-01

    The motivation for this intercomparison came from data needs of accelerator-based waste transmutation, energy amplification and medical therapy. The aim of this exercise is to determine the degree of reliability of current nuclear reaction models and codes when calculating activation yields in the intermediate energy range up to 5000 MeV. Emphasis has been placed for a wide range of target elements ( O, Al, Fe, Co, Zr and Au). This work is mainly based on calculation of (P,xPyN) integral cross section for incident proton. A qualitative description of some of the nuclear models and code options employed is made. The systematics of graphical presentation of the results allows a quick quantitative measure of agreement or deviation. This code intercomparison highlights the fact that modeling calculations of energy activation yields may at best have uncertainties of a factor of two. The causes of such discrepancies are multi-factorial. Problems are encountered which are connected with the calculation of nuclear masses, binding energies, Q-values, shell effects, medium energy fission and Fermi break-up. (A.C.)

  16. Intercomparison of natural radionuclide measurements in marine sediment sample SD-N-1/2

    International Nuclear Information System (INIS)

    1985-06-01

    This intercomparison exercise was organized with the aim of providing to the participating laboratories a possibility of testing the performance of their analytical methods and to acquire basic data for establishing reference values for a number of natural radionuclides in the sediment material SD-N-1/2 from the North Sea floor. In tables are presented results expressed in mBq.g -1 on potassium, uranium isotopes, thorium-232 with the respective decay products, thorium-230, radium-226 and lead-210. Altogether 98 laboratories from 42 Member States joined this intercomparison. The results show generally good agreement, but more analytical work is needed to improve the present status of the lead-210 certification. Gamma and alpha spectroscopy were the most frequently used as the analytical techniques

  17. Ice Sheet Model Intercomparison Project (ISMIP6) contribution to CMIP6

    NARCIS (Netherlands)

    Nowicki, Sophie M J; Payne, Anthony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko|info:eu-repo/dai/nl/412549123; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2016-01-01

    Reducing the uncertainty in the past, present, and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model

  18. Report on intercomparison air-3/1 of the determination of trace elements in simulated air filters

    International Nuclear Information System (INIS)

    Pszonicki, L.; Veglia, A.; Suschny, O.

    1982-06-01

    The report is a sum up of an intercomparison experiment organized by the Analytical Quality Control Service of the IAEA, for simulated air filters (Air-3/1) spiked with 17 trace elements. The purpose was twofold: to assist participating laboratories in controlling their own performance, and to characterize exactly the prepared batch of air filters in order to be able to use them as reference filters for elemental trace analysis. The results submitted by 29 laboratories from 20 countries are presented and statistically processed. The analytical methods used are also specified. Conclusions concerning the use of filters Air-3/1 as certified reference filters are presented

  19. In-situ gammaspectrometry intercomparison exercise in Salzburg/Austria

    International Nuclear Information System (INIS)

    Steger, F.; Lovranich, E.; Lettner, H.; Andrasi, A.

    1996-01-01

    In-situ gamma-spectrometry has become a useful method of assessing the nuclide concentrations of man-made and natural gamma-emitters in the soil. For the quality assurance of the measurements, periodically conducted intercomparison exercises are essential. Therefore exercises were organized in different European countries since 1990, the last one was conducted in Salzburg /Austria in September 1994. The participation of 24 measurement-teams from all over Europe emphasizes the importance of the intercomparison. Salzburg was selected because the Province of Salzburg /Austria was among the most heavily contaminated regions outside the former USSR by the Chernobyl fallout. Two different typical sites were selected for the measurements: Site 1 was inside the urban area of Salzburg on intensively used grassland which had not been tilled since the deposition of the fallout. This site is representative for intensively used agricultural regions in the Province of Salzburg. Site 2 was in the mountainous regions of the Hohe Tauern at an elevated altitude of 1600 m, representing the agricultural soil- and contamination conditions of the Alpine regions in the Tauern. The two sites differ significantly in terms of soil characteristics, a crucial parameter for the evaluation of in-situ gamma-spectra. The participants used different approaches for the evaluation of the gamma-spectra in terms of considering the depth distribution. In the paper the results from the 24 European teams are presented. (author)

  20. Intercomparison exercise on internal dose assessment. Final report of a joint IAEA-IDEAS project

    International Nuclear Information System (INIS)

    2007-09-01

    There have been several intercomparison exercises organized already at national and international levels for the assessment of occupational exposure due to intakes of radionuclides. These intercomparison exercises revealed significant differences in approaches, methods and assumptions, and consequently in the results. Because of the relevance of the issue for internal dosimetrists, the IAEA organized a new intercomparison exercise in cooperation with the IDEAS project General Guidelines for the Evaluation of Incorporation Monitoring Data, launched under the 5th EU Framework Programme (EU Contract No. FIKR-CT2001-00160). This new intercomparison exercise focused especially on the effect of the guidelines for harmonization of internal dosimetry. It also considered the following aspects: - to provide possibilities for the participating laboratories to check the quality of their internal dose assessment methods in applying the recent ICRP recommendations (e.g. for the new respiratory tract model); - to compare different approaches in interpretation of internal contamination monitoring data; - to quantify the differences in internal dose assessments based on the new guidelines or on other procedures, respectively; - to provide some figures for the influence of the input parameters on the monitoring results; and - to provide a broad forum for information exchange. Several cases have been selected for this exercise with the aim of covering a wide range of practices in the nuclear fuel cycle and in medical applications. The cases were: 1. Acute intake of HTO; 2. Acute inhalation of fission products 137 Cs and 90 Sr; 3. Intake of 60 Co; 4. Repeated intakes of 131 I; 5. Intake of enriched uranium; 6. Single intake of plutonium radionuclides and 241 Am. An Internet based approach had been used for the presentation of the cases, collection of responses and potential discussion of the results. Solutions to these cases were reported by 80 participants worldwide. This report

  1. In-situ-gamma-spectrometry intercomparison exercise in Salzburg, Austria, September 26-30, 1994

    International Nuclear Information System (INIS)

    Steger, F.; Lettner, H.; Andrasi, A.

    1996-06-01

    In-situ gamma spectrometry has become a useful method to assess the nuclide concentration of artificial and natural gamma-emitters in the soil. With such measurements it is possible to calculate the activity concentration in soil and also the nuclide specific exposure rates 1 m above ground. For the quality assurance of the measurements periodically intercomparison exercises are essential. To meet this requirement exercises were organised in different European countries since 1989. The last exercise in September 1994 was organised in Salzburg / Austria. The participation of 24 measurement teams from all over Europe emphasises the importance of the intercomparison. Salzburg was selected because the Province of Salzburg / Austria was among the heaviest contaminated region outside the former USSR by the Chernobyl fallout. Two different typical sites were selected for the measurements: Site 1 was inside the urban area of Salzburg on intensively used agricultural land which had not been disturbed since the fallout. This site is representative for intensively used agricultural regions in the Province of Salzburg. Site 2 was in the mountainous region of the Tauern on elevated altitude of approx. 1700 m. This site represents the soil and contamination conditions of the Alpine region. Both sites differ significantly in terms of different soil distribution and contents of natural and artificial radionuclides. Results of the intercomparison exercise are presented. (author)

  2. DRDC Ottawa Participation in the SILENE Accident Dosimetry Intercomparison Exercise. June 10-21, 2002

    National Research Council Canada - National Science Library

    Prud'homme-Lalonde, L

    2002-01-01

    .... The SILENE International Accident Dosimetry Intercomparison Exercise at Valduc, France in June 2002 coincided with DRDC Ottawa work designed to refine its proposed criticality dosimetry system...

  3. Low-Level Waste Drum Assay Intercomparison Study

    International Nuclear Information System (INIS)

    Greutzmacher, K.; Kuzminski, J.; Myers, S. C.

    2003-01-01

    Nuclear waste assay is an integral element of programs such as safeguards, waste management, and waste disposal. The majority of nuclear waste is packaged in drums and analyzed by various nondestructive assay (NDA) techniques to identify and quantify the radioactive content. Due to various regulations and the public interest in nuclear issues, the analytical results are required to be of high quality and supported by a rigorous Quality Assurance (QA) program. A valuable QA tool is an intercomparison program in which a known sample is analyzed by a number of different facilities. While transuranic waste (TRU) certified NDA teams are evaluated through the Performance Demonstration Program (PDP), low-level waste (LLW) assay specialists have not been afforded a similar opportunity. NDA specialists from throughout the DOE complex were invited to participate in this voluntary drum assay intercomparison study that was organized and facilitated by the Solid Waste Operations and the Safeguards Science and Technology groups at the Los Alamos National Laboratory and by Eberline Services. Each participating NDA team performed six replicate blind measurements of two 55-gallon drums with relatively low-density matrices (a 19.1 kg shredded paper matrix and a 54.4 kg mixed metal, rubber, paper and plastic matrix). This paper presents the results from this study, with an emphasis on discussing the lessons learned as well as desirable follow up programs for the future. The results will discuss the accuracy and precision of the replicate measurements for each NDA team as well as any issues that arose during the effort

  4. Thematic network on the analysis of thorium and its isotopes in workplace materials. Report on the 2nd intercomparison exercise

    International Nuclear Information System (INIS)

    Howe, A.; White, M.

    2000-12-01

    Work Package 2 (WP 2) of the EC Thematic Network on ''The analysis of thorium and its isotopes in workplace materials'' is concerned with ''Examination and comparison of analytical techniques for the determination of thorium and its progeny in bulk materials and the development of standards, both for the calibration of associated metrological facilities, and for routine quality control purposes''. The primary objective of WP 2 is ''To evaluate appropriate techniques and determine best practice for analysis of 232 Th at workplace levels and environments'', and is to be achieved through a series of intercomparison exercises. Following the results of the 1st intercomparison exercise, a 2nd intercomparison exercise was designed to evaluate the capability of the analytical methods currently being used by European laboratories to determine thorium at very low levels in the presence of a complex inorganic matrix. The intercomparison exercise involved the analysis of three samples of thorium in solution, prepared by the United Kingdom National Physical Laboratory. One sample was the equilibrium solution, analysed in the 1st intercomparison exercise. The other two samples were prepared by dilution of a non-equilibrium thorium solution, one of which was spiked with impurity elements. (i) The results showed a further improvement in the accuracy of measurements in the equilibrium solution, when compared with the results from the 1st intercomparison study. There was an overall drop in u-test values and the number of u-test values above the upper limit of significance fell from 6 to 3. (ii) Overall, participating laboratories also performed well in the analysis of the low level non-equilibrium solutions. However, several laboratories using y-spectrometry had insufficient sensitivity for measurement of low level non-equilibrium sample solutions and did not report results. (iii) There was little evidence that the presence of impurities had a detrimental effect on measurements made

  5. Instrument intercomparison in the pulsed neutron fieldsat the CERN HiRadMat facility

    CERN Document Server

    Aza, E; Cassell, C; Charitonidis, N; Harrouch, E; Manessi, G P; Pangallo, M; Perrin, D; Samara, E; Silari, M

    2014-01-01

    An intercomparison of the performances of active neutron detectors was carried out in pulsed neutron fi elds in the new HiRadMat facility at CERN. Five detectors were employed: four of them (two ionization chambers and two rem counters) are routinely employed in the CERN radiation monitoring system, while the fi fth is a novel instrument, called LUPIN, speci fi cally conceived for applications in pulsed neutron fi elds. The measurements were performed in the stray fi eld generated by a proton beam of very short duration with momentum of 440 GeV/c impinging on a dump. The beam intensity was steadily increased during the experiment by more than three orders of magnitude, with an H*(10) due to neutrons at the detector reference positions varying between a few nSv per burst and a few m Sv per burst, whereas the gamma contribution to the total H*(10) was negligible. The aim of the experiment was to evaluate the linearity of the detector response in extreme pulsed conditions as a function of the neutron burst in- t...

  6. Inter-comparison of GRACE data over India

    Science.gov (United States)

    Banerjee, Chandan; Kumar, D. Nagesh

    2016-05-01

    The advent of satellite remote sensing and its use in hydrology has facilitated a huge leap in the understanding of the various water resources, its interaction with ecological systems and anthropogenic creations. Recently, NASA and German Aerospace Research Agency-DLR launched the Gravity Recovery and Climate Experiment (GRACE) satellite mission consisting of two satellites. They measure the time varying gravity which gives changes in the distribution of mass on the surface of the earth which after removing atmospheric and oceanic effects is majorly caused by changes in Terrestrial Water Storage (TWS) changes. GRACE data is generally available as spherical harmonic coefficients, which is difficult for hydrologists to understand and interpret. JPL's TELLUS website is now providing gridded global data set in the form of mass anomaly derived from the Level-2 data sets of spherical harmonic coefficients of 3 sources, viz. CSR, GFZ and JPL. Before using these data sets for solving hydrological problems, it is important to understand the differences and similarities between these data sets as direct calibration of GRACE data is not possible. In this study we do an inter-comparison of the Level-3 Release 05 data sets over India. We compare the data sets using Pearson, Spearman and Kendall correlation. CSR and GFZ data sets appear to be closest to each other whereas JPL and GFZ data sets are most different from each other.

  7. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  8. GODAE Inter-Comparisons in the Tasman and Coral Seas

    Science.gov (United States)

    2012-08-01

    and salinity. All have their strengths and weaknesses, and each system out-performs all others in one aspect or another. With few exceptions, all... Auckland and Fiji (Fig 1), was occupied during the inter- comparison period. The observed T section from this line is shown in Fig 6a. Comparisons of T...has certain strengths and weaknesses. Inter-comparisons are regarded as valuable exer- cises that provide important insights into the ocean forecast

  9. Assessing Agricultural Risks of Climate Change in the 21st Century in a Global Gridded Crop Model Intercomparison

    Science.gov (United States)

    Rosenzweig, Cynthia E.; Elliott, Joshua; Deryng, Delphine; Ruane, Alex C.; Mueller, Christoph; Arneth, Almut; Boote, Kenneth J.; Folberth, Christian; Glotter, Michael; Khabarov, Nikolay

    2014-01-01

    Here we present the results from an intercomparison of multiple global gridded crop models (GGCMs) within the framework of the Agricultural Model Intercomparison and Improvement Project and the Inter-Sectoral Impacts Model Intercomparison Project. Results indicate strong negative effects of climate change, especially at higher levels of warming and at low latitudes; models that include explicit nitrogen stress project more severe impacts. Across seven GGCMs, five global climate models, and four representative concentration pathways, model agreement on direction of yield changes is found in many major agricultural regions at both low and high latitudes; however, reducing uncertainty in sign of response in mid-latitude regions remains a challenge. Uncertainties related to the representation of carbon dioxide, nitrogen, and high temperature effects demonstrated here show that further research is urgently needed to better understand effects of climate change on agricultural production and to devise targeted adaptation strategies.

  10. Intercomparison Of Activity Measurements Of Co-58, Y-88, Ho-166m, Tc-99m, dan I-131 Between P3KRBiN and Laboratory Within BATAN And Hospitals

    International Nuclear Information System (INIS)

    Nazaroh; Ermi-Juita; Hermawan-Candra

    2003-01-01

    One way to maintain traceability and to keep consistency of the measurement result of radioactivity was intercomparison program. According with Surat Keputusan Kepala BATAN No.73/KA/IV/99, one of tasks and functions of standardization laboratory is to coordinate an intercomparison program of radioactivity measurement. In the year of 2000, intercomparison program of activity measurements between P3KRBiN and 10 laboratories within BATAN and 12 hospitals were carried out. For intercomparison of Co-58, Y-88, and Ho-166m, there were 3 laboratories within BATAN which have more than 50% difference compared with P3KRBiN measurements and for intercomparison of Tc-99m, dan I-131, there were 2 Dose-Calibrators belongs to hospitals which have more than 30% difference compared with P3KRBiN measurements. From that result it can be concluded that intercomparison of activity measurements are very important and needs continuously to maintain traceability and to keep consistency of measurement result. (author)

  11. The ARM-GCSS Intercomparison Study of Single-Column Models and Cloud System Models

    International Nuclear Information System (INIS)

    Cederwall, R.T.; Rodriques, D.J.; Krueger, S.K.; Randall, D.A.

    1999-01-01

    The Single-Column Model (SCM) Working Group (WC) and the Cloud Working Group (CWG) in the Atmospheric Radiation Measurement (ARM) Program have begun a collaboration with the GEWEX Cloud System Study (GCSS) WGs. The forcing data sets derived from the special ARM radiosonde measurements made during the SCM Intensive Observation Periods (IOPs), the wealth of cloud and related data sets collected by the ARM Program, and the ARM infrastructure support of the SCM WG are of great value to GCSS. In return, GCSS brings the efforts of an international group of cloud system modelers to bear on ARM data sets and ARM-related scientific questions. The first major activity of the ARM-GCSS collaboration is a model intercomparison study involving SCMs and cloud system models (CSMs), also known as cloud-resolving or cloud-ensemble models. The SCM methodologies developed in the ARM Program have matured to the point where an intercomparison will help identify the strengths and weaknesses of various approaches. CSM simulations will bring much additional information about clouds to evaluate cloud parameterizations used in the SCMs. CSMs and SCMs have been compared successfully in previous GCSS intercomparison studies for tropical conditions. The ARM Southern Great Plains (SGP) site offers an opportunity for GCSS to test their models in continental, mid-latitude conditions. The Summer 1997 SCM IOP has been chosen since it provides a wide range of summertime weather events that will be a challenging test of these models

  12. Third Radiation Transfer Model Intercomparison (RAMI) exercise : Documenting progress in canopy reflectance models

    NARCIS (Netherlands)

    Widlowski, J.-L.; Taberner, M.; Pinty, B.; Bruniquel-Pinel, V.; Disney, M.; Fernandes, R.; Gastellu-Etchegorry, J.P.; Gobron, N.; Kuusk, A.; Lavergne, T.; Leblanc, S.; Lewis, P.E.; Martin, E.; Mottus, M.; North, P.R.J.; Qin, W.; Robustelli, M.; Rochdi, N.; Ruiloba, R.; Soler, C.; Thompson, R.; Verhoef, W.; Xie, D.; Thompson, R.

    2007-01-01

    The Radiation Transfer Model Intercomparison (RAMI) initiative benchmarks canopy reflectance models under well‐controlled experimental conditions. Launched for the first time in 1999, this triennial community exercise encourages the systematic evaluation of canopy reflectance models on a voluntary

  13. Ice Sheet Model Intercomparison Project (ISMIP6) Contribution to CMIP6

    Science.gov (United States)

    Nowicki, Sophie M. J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2016-01-01

    Reducing the uncertainty in the past, present, and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project phase 6 (CMIP6) focusing on the Greenland and Antarctic ice sheets. In this paper, we describe the framework for ISMIP6 and its relationship with other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice-sheetclimate models as well as standalone ice-sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice-sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change.

  14. Ice Sheet Model Intercomparison Project (ISMIP6) contribution to CMIP6

    Science.gov (United States)

    Nowicki, Sophie M.J.; Payne, Tony; Larour, Eric; Seroussi, Helene; Goelzer, Heiko; Lipscomb, William; Gregory, Jonathan; Abe-Ouchi, Ayako; Shepherd, Andrew

    2018-01-01

    Reducing the uncertainty in the past, present and future contribution of ice sheets to sea-level change requires a coordinated effort between the climate and glaciology communities. The Ice Sheet Model Intercomparison Project for CMIP6 (ISMIP6) is the primary activity within the Coupled Model Intercomparison Project – phase 6 (CMIP6) focusing on the Greenland and Antarctic Ice Sheets. In this paper, we describe the framework for ISMIP6 and its relationship to other activities within CMIP6. The ISMIP6 experimental design relies on CMIP6 climate models and includes, for the first time within CMIP, coupled ice sheet – climate models as well as standalone ice sheet models. To facilitate analysis of the multi-model ensemble and to generate a set of standard climate inputs for standalone ice sheet models, ISMIP6 defines a protocol for all variables related to ice sheets. ISMIP6 will provide a basis for investigating the feedbacks, impacts, and sea-level changes associated with dynamic ice sheets and for quantifying the uncertainty in ice-sheet-sourced global sea-level change. PMID:29697697

  15. Dose intercomparison study involving Fricke, ethanol chlorobenzene, PMMA and alanine dosimeters

    International Nuclear Information System (INIS)

    Lanuza, L.G.; Cabalfin, E.G.; Kojima, T.; Tachibana, H.

    1999-01-01

    A dose intercomparison study was carried out between the Philippine Nuclear Research Institute (PNRI) and Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research Institute (JAERI) to determine reliability of the dosimetry systems being used by PNRI employing ethanol chlorobenzene (ECB), Fricke and alanine dosimeters. The Fricke and ECB dosimeters were prepared at PNRI while the alanine-polystyrene dosimeter was provided by JAERI. Fricke or ECB dosimeters were irradiated together with alanine at PNRI gamma irradiation facilities. Analyses of the Fricke and ECB dosimeters were performed at PNRI while alanine dosimeters were analyzed at JAERI. A comparison study between alanine and polymethylmethacrylate (PMMA, Radix RN15) dosimeters was also undertaken at JAERI. The dosimeters were irradiated together under different irradiation conditions using the gamma irradiation facilities of JAERI and Radia Industry Co. Ltd. (Japan). Evaluations of PMMA and alanine dosimeters were both performed at JAERI. Result of the dose intercomparison of PNRI with the International Atomic Energy Agency through the International Dose Assurance Service (IDAS) is also presented. (author)

  16. Dose intercomparison study involving Fricke, ethanol chlorobenzene, PMMA and alanine dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Lanuza, L G; Cabalfin, E G [Philippine Nuclear Research Institute, Quezon City (Philippines); Kojima, T; Tachibana, H [Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research institute, Takasaki (Japan)

    1999-03-01

    A dose intercomparison study was carried out between the Philippine Nuclear Research Institute (PNRI) and Takasaki Radiation Chemistry Research Establishment, Japan Atomic Energy Research Institute (JAERI) to determine reliability of the dosimetry systems being used by PNRI employing ethanol chlorobenzene (ECB), Fricke and alanine dosimeters. The Fricke and ECB dosimeters were prepared at PNRI while the alanine-polystyrene dosimeter was provided by JAERI. Fricke or ECB dosimeters were irradiated together with alanine at PNRI gamma irradiation facilities. Analyses of the Fricke and ECB dosimeters were performed at PNRI while alanine dosimeters were analyzed at JAERI. A comparison study between alanine and polymethylmethacrylate (PMMA, Radix RN15) dosimeters was also undertaken at JAERI. The dosimeters were irradiated together under different irradiation conditions using the gamma irradiation facilities of JAERI and Radia Industry Co. Ltd. (Japan). Evaluations of PMMA and alanine dosimeters were both performed at JAERI. Result of the dose intercomparison of PNRI with the International Atomic Energy Agency through the International Dose Assurance Service (IDAS) is also presented. (author) 8 refs, 3 figs, 4 tabs

  17. IAEA/IDEAS intercomparison exercise on internal dose assessment

    International Nuclear Information System (INIS)

    Doerfel, H.; Andrasi, A.; Cruz-Suarez, R.; Castellani, C. M.; Hurtgen, C.; Marsh, J.; Zeger, J.

    2007-01-01

    An Internet based intercomparison exercise on assessment of occupational exposure due to intakes of radionuclides has been performed to check the applicability of the 'General Guidelines for the Assessment of Internal Dose from Monitoring Data' developed by the IDEAS group. There were six intake cases presented on the Internet and 81 participants worldwide reported solutions to these cases. Results of the exercise indicate that the guidelines have a positive influence on the methodologies applied for dose assessments and, if correctly applied, improve the harmonisation of assessed doses. (authors)

  18. Intercomparison measurements with albedo neutron dosimeters

    International Nuclear Information System (INIS)

    Alberts, W.G.; Kluge, H.

    1994-01-01

    Since the introduction of the albedo dosimeter as the official personal neutron dosimeter the dosimetry services concerned have participated in intercomparison measurements at the PTB. Their albedo dosimeters were irradiated in reference fields produced by unmoderated and D 2 O-moderated 252 Cf neutron sources in the standard irradiation facility of the PTB. Six fields with fluences different in energy and angle distribution could be realised in order to determine the response of the albedo dosimeter. The dose equivalent values evaluated by the services were compared with the reference values of the PTB for the directional dose equivalent H'(10). The results turned out to be essentially dependent on the evaluation method and the choice of the calibration factors. (orig.) [de

  19. Intercomparison of SO2 camera systems for imaging volcanic gas plumes

    Science.gov (United States)

    Kern, Christoph; Lübcke, Peter; Bobrowski, Nicole; Campion, Robin; Mori, Toshiya; Smekens, Jean-Francois; Stebel, Kerstin; Tamburello, Giancarlo; Burton, Mike; Platt, Ulrich; Prata, Fred

    2015-01-01

    SO2 camera systems are increasingly being used to image volcanic gas plumes. The ability to derive SO2 emission rates directly from the acquired imagery at high time resolution allows volcanic process studies that incorporate other high time-resolution datasets. Though the general principles behind the SO2 camera have remained the same for a number of years, recent advances in CCD technology and an improved understanding of the physics behind the measurements have driven a continuous evolution of the camera systems. Here we present an intercomparison of seven different SO2 cameras. In the first part of the experiment, the various technical designs are compared and the advantages and drawbacks of individual design options are considered. Though the ideal design was found to be dependent on the specific application, a number of general recommendations are made. Next, a time series of images recorded by all instruments at Stromboli Volcano (Italy) is compared. All instruments were easily able to capture SO2 clouds emitted from the summit vents. Quantitative comparison of the SO2 load in an individual cloud yielded an intra-instrument precision of about 12%. From the imagery, emission rates were then derived according to each group's standard retrieval process. A daily average SO2 emission rate of 61 ± 10 t/d was calculated. Due to differences in spatial integration methods and plume velocity determination, the time-dependent progression of SO2 emissions varied significantly among the individual systems. However, integration over distinct degassing events yielded comparable SO2 masses. Based on the intercomparison data, we find an approximate 1-sigma precision of 20% for the emission rates derived from the various SO2 cameras. Though it may still be improved in the future, this is currently within the typical accuracy of the measurement and is considered sufficient for most applications.

  20. Reflecting on the challenges of building a rich interconnected metadata database to describe the experiments of phase six of the coupled climate model intercomparison project (CMIP6) for the Earth System Documentation Project (ES-DOC) and anticipating the opportunities that tooling and services based on rich metadata can provide.

    Science.gov (United States)

    Pascoe, C. L.

    2017-12-01

    The Coupled Model Intercomparison Project (CMIP) has coordinated climate model experiments involving multiple international modelling teams since 1995. This has led to a better understanding of past, present, and future climate. The 2017 sixth phase of the CMIP process (CMIP6) consists of a suite of common experiments, and 21 separate CMIP-Endorsed Model Intercomparison Projects (MIPs) making a total of 244 separate experiments. Precise descriptions of the suite of CMIP6 experiments have been captured in a Common Information Model (CIM) database by the Earth System Documentation Project (ES-DOC). The database contains descriptions of forcings, model configuration requirements, ensemble information and citation links, as well as text descriptions and information about the rationale for each experiment. The database was built from statements about the experiments found in the academic literature, the MIP submissions to the World Climate Research Programme (WCRP), WCRP summary tables and correspondence with the principle investigators for each MIP. The database was collated using spreadsheets which are archived in the ES-DOC Github repository and then rendered on the ES-DOC website. A diagramatic view of the workflow of building the database of experiment metadata for CMIP6 is shown in the attached figure.The CIM provides the formalism to collect detailed information from diverse sources in a standard way across all the CMIP6 MIPs. The ES-DOC documentation acts as a unified reference for CMIP6 information to be used both by data producers and consumers. This is especially important given the federated nature of the CMIP6 project. Because the CIM allows forcing constraints and other experiment attributes to be referred to by more than one experiment, we can streamline the process of collecting information from modelling groups about how they set up their models for each experiment. End users of the climate model archive will be able to ask questions enabled by the

  1. The Community Intercomparison Suite (CIS)

    Science.gov (United States)

    Watson-Parris, Duncan; Schutgens, Nick; Cook, Nick; Kipling, Zak; Kershaw, Phil; Gryspeerdt, Ed; Lawrence, Bryan; Stier, Philip

    2017-04-01

    Earth observations (both remote and in-situ) create vast amounts of data providing invaluable constraints for the climate science community. Efficient exploitation of these complex and highly heterogeneous datasets has been limited however by the lack of suitable software tools, particularly for comparison of gridded and ungridded data, thus reducing scientific productivity. CIS (http://cistools.net) is an open-source, command line tool and Python library which allows the straight-forward quantitative analysis, intercomparison and visualisation of remote sensing, in-situ and model data. The CIS can read gridded and ungridded remote sensing, in-situ and model data - and many other data sources 'out-of-the-box', such as ESA Aerosol and Cloud CCI product, MODIS, Cloud CCI, Cloudsat, AERONET. Perhaps most importantly however CIS also employs a modular plugin architecture to allow for the reading of limitless different data types. Users are able to write their own plugins for reading the data sources which they are familiar with, and share them within the community, allowing all to benefit from their expertise. To enable the intercomparison of this data the CIS provides a number of operations including: the aggregation of ungridded and gridded datasets to coarser representations using a number of different built in averaging kernels; the subsetting of data to reduce its extent or dimensionality; the co-location of two distinct datasets onto a single set of co-ordinates; the visualisation of the input or output data through a number of different plots and graphs; the evaluation of arbitrary mathematical expressions against any number of datasets; and a number of other supporting functions such as a statistical comparison of two co-located datasets. These operations can be performed efficiently on local machines or large computing clusters - and is already available on the JASMIN computing facility. A case-study using the GASSP collection of in-situ aerosol observations

  2. An international marine-atmospheric 222Rn measurement intercomparison in Bermuda. Part 2: Results for the participating laboratories

    International Nuclear Information System (INIS)

    Colle, R.; Unterweger, M.P.; Hutchinson, J.M.R.

    1996-01-01

    As part of an international measurement intercomparison of instruments used to measure atmospheric 222 Rn, four participating laboratories made nearly simultaneous measurements of 222 Rn activity concentration in commonly sampled, ambient air over approximately a 2 week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (blind) 222 Rn activity concentration. The exercise was conducted in Bermuda in October 1991. The 222 Rn activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths of a Bq · m -3 to about 2 Bq · m -3 , while the standardized sample additions covered a range from approximately 2.5 Bq · m -3 to 35 Bq · m -3 . The overall uncertainty in the latter concentrations was in the general range of 10%, approximating a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions, and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq · m -3 . The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65% to 70%, with respect to the standard addition which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two laboratories

  3. Intercomparison of different operational oceanographic forecast products in the CMEMS IBI area

    Science.gov (United States)

    Lorente, Pablo; Sotillo, Marcos G.; Dabrowski, Tomasz; Amo-Baladrón, Arancha; Aznar, Roland; De Pascual, Alvaro; Levier, Bruno; Bowyer, Peter; Cossarini, Gianpiero; Salon, Stefano; Tonani, Marina; Alvarez-Fanjul, Enrique

    2017-04-01

    The development of skill assessment software packages and dedicated web applications is a relatively novel theme in operational oceanography. Within the CMEMS IBI-MFC, the quality of IBI (Iberia-Biscay-Ireland) forecast products is assessed by means of NARVAL (North Atlantic Regional VALidation) web-based tool. The validation of IBI against independent in situ and remote-sensing measurements is routinely conducted to evaluate model's veracity and prognostic capabilities. Noticeable efforts are in progress to define meaningful skill scores and statistical metrics to quantitatively assess the quality and reliability of the IBI model solution. Likewise, the IBI-MFC compares the IBI forecast products with other model solutions by setting up specific intercomparison exercises on overlapping areas at diverse timescales. In this context, NARVAL web tool already includes a specific module to evaluate strengths and weaknesses of IBI versus other CMEMS operational ocean forecasting systems (OOFSs). In particular, the IBI physical ocean solution is compared against the CMEMS MED and NWS OOFSs. These CMEMS regional services delivered for the Mediterranean and the North West Shelves include data assimilation schemes in their respective operational chains and generate analogous ocean forecast products to the IBI ones. A number of physical parameters (i.e. sea surface temperature, salinity and current velocities) are evaluated through NARVAL on a daily basis in the overlapping areas existing between these three regional systems. NARVAL is currently being updated in order to extend this intercomparison of ocean model parameters to the biogeochemical solutions provided by the aforementioned OOFSs. More specifically, the simulated chlorophyll concentration is evaluated over several subregions of particular concern by using as benchmark the CMEMS satellite-derived observational products. In addition to this IBI comparison against other regional CMEMS products on overlapping areas, a

  4. A community-wide intercomparison exercise for the determination of dissolved iron in seawater

    NARCIS (Netherlands)

    Bowie, A.R.; Achterberg, E.P.; Croot, P.l.; de Baar, H.J.W.; Laan, P.; Moffett, J.W; Ussher, S.; Worsfold, P.J.

    2006-01-01

    The first large-scale international intercomparison of analytical methods for the determination of dissolved iron in seawater was carried out between October 2000 and December 2002. The exercise was conducted as a rigorously "blind" comparison of 7 analytical techniques by 24 international

  5. Meteorological conditions at the release site during the two tracer experiments

    DEFF Research Database (Denmark)

    Gryning, Sven-Erik; Batchvarova, E.; Schneiter, D.

    1998-01-01

    The state of the boundary layer at the release site during the two tracer experiments is described, based on measurements of atmospheric turbulence carried our by a sonic anemometer, profiles of horizontal and vertical wind by a SODAR as well as frequent radiosonde releases. The boundary layer...... height is derived from radiosoundings, modelled and discussed. The study is meant as background for discussions of the tracer behaviour near the release site, and possible influence of the local meteorology at the release site on the long-range dispersion. The difference in the initial mese...... model development. It is concluded that the micrometeorological measurements are very important as background information for the understanding of plume behaviour on small as well as long scales. (C) 1998 Elsevier Science Ltd. All rights reserved....

  6. Results obtained in the intercomparison of dosimetry systems Total body organized by In 2012, the European Group for radiation dosimetry (EURADOS) has organized an intercomparison of systems; Resultados obtenidos en la intercomparacion de sistemas dosimetricos de cuerpo entero organizada pro Eurados (IC2012)

    Energy Technology Data Exchange (ETDEWEB)

    Casal Zamorano, E.; Soriano Cruz, A.; Alabau Albors, J.; Palma Copete, J. D.

    2013-07-01

    dosimetric full-length for photons, within the action on {sup h}armonization of the monitoring Individual of the radiation External{sup e}stablished by the group. 88 dosimetric systems, 75 30 institutions have participated in the intercomparison countries. Each participant has sent a group of 26 dosimeters which have been irradiated with various doses and radiation qualities. The overall results of the intercomparison were presented recently (1). This communication presents the results obtained by our Center. EURADOS (IC2012). (Author)

  7. Development of a transfer instrument for neutron dosimetry intercomparison

    International Nuclear Information System (INIS)

    Greene, D.; Miles, J.

    1974-01-01

    Comparisons are reported for fast neutron dosemeters which were designed to be transportable so as to enable intercomparisons between institutions using neutrons for radiotherapy or radiobiology. The systems considered are : 1) the ferrous sulphate dosemeter, 2) the lithium fluoride thermoluminescent dosemeter, 3) ionization chambers with various walls and gases. Work on photographic film dosimetry indicated that the system was not suitable and was not pursued. The sources used were 60 Co, the cyclotron at Hammersmith Hospital in London and 252 Cf

  8. Experimental design for three interrelated marine ice sheet and ocean model intercomparison projects: MISMIP v. 3 (MISMIP +), ISOMIP v. 2 (ISOMIP +) and MISOMIP v. 1 (MISOMIP1)

    Energy Technology Data Exchange (ETDEWEB)

    Asay-Davis, Xylar S. [Potsdam Inst. for Climate Impact Research (Germany). Earth System Analysis; Cornford, Stephen L. [Univ. of Bristol (United Kingdom). Centre for Polar Observation and Modelling; Durand, Gaël [Centre National de la Recherche Scientifique (CNRS), Grenoble (France); Univ. of Grenoble (France); Galton-Fenzi, Benjamin K. [Australian Antarctic Division and Antarctic Climate and Ecosystems Cooperative Research Centre, Tasmania (Australia); Gladstone, Rupert M. [Antarctic Climate and Ecosystems Cooperative Research Centre, Tasmania (Australia); ETH Zurich (Switzerland). Research Center for Hydraulic Engineering; Gudmundsson, G. Hilmar [British Antarctic Survey, Cambridge (United Kingdom); Hattermann, Tore [Akvaplan-niva, Tromso (Norway); Helmholtz Centre for Polar and Marine Research, Bremerhaven (Germany). Alfred Wegener Inst.; Holland, David M. [New York Univ. (NYU), NY (United States)' . Courant Inst. of Mathematical Sciences; Holland, Denise [New York Univ. (NYU), Abu Dahabi (United Arab Emirates); Holland, Paul R. [British Antarctic Survey, Cambridge (United Kingdom); Martin, Daniel F. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathiot, Pierre [British Antarctic Survey, Cambridge (United Kingdom); Met Office, Exeter (United Kingdom); Pattyn, Frank [Univ. of Libre, Brussels (Belgium). Lab. of Glaciology; Seroussi, Hélène [California Inst. of Technology (CalTech), Pasadena, CA (United States). Jet Propulsion Lab.

    2016-01-01

    Coupled ice sheet-ocean models capable of simulating moving grounding lines are just becoming available. Such models have a broad range of potential applications in studying the dynamics of marine ice sheets and tidewater glaciers, from process studies to future projections of ice mass loss and sea level rise. The Marine Ice Sheet-Ocean Model Intercomparison Project (MISOMIP) is a community effort aimed at designing and coordinating a series of model intercomparison projects (MIPs) for model evaluation in idealized setups, model verification based on observations, and future projections for key regions of the West Antarctic Ice Sheet (WAIS).

    Here we describe computational experiments constituting three interrelated MIPs for marine ice sheet models and regional ocean circulation models incorporating ice shelf cavities. These consist of ice sheet experiments under the Marine Ice Sheet MIP third phase (MISMIP+), ocean experiments under the Ice Shelf-Ocean MIP second phase (ISOMIP+) and coupled ice sheet-ocean experiments under the MISOMIP first phase (MISOMIP1). All three MIPs use a shared domain with idealized bedrock topography and forcing, allowing the coupled simulations (MISOMIP1) to be compared directly to the individual component simulations (MISMIP+ and ISOMIP+). The experiments, which have qualitative similarities to Pine Island Glacier Ice Shelf and the adjacent region of the Amundsen Sea, are designed to explore the effects of changes in ocean conditions, specifically the temperature at depth, on basal melting and ice dynamics. In future work, differences between model results will form the basis for the evaluation of the participating models.

  9. Report on the intercomparison of determinations of {sup 89}Sr, {sup 90}Sr and {sup 137}Cs in liquid milk, A-9 (1975-76)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1976-05-01

    The ever growing concern of modern societies about environmental pollution imposes serious responsibility on the analytical chemist who is entrusted with the task of monitoring the levels of both radioactive and conventional pollutants in various environmental samples. The main requirement for this service to be effective is that it must furnish reliable i.e. accurate and sufficiently precise results. Hence, the necessity of periodic checking of the analytical performance of any laboratory is now more and more widely recognized. Such a check-up is of importance both to laboratories newly entering the field which are but acquiring the necessary experience, as well as to renowned laboratories in which interchange of the staff, modifications of the procedure or simply excessive routine may also sometimes lead to erroneous results. The analytical quality control service of the IAEA has organized already in the past intercomparisons on the determination of certain radionuclides in simulated liquid milk. The success of these exercises has induced the Agency to organize the new intercomparison of this series in 1975-76, the results of which are presented in this report.

  10. Inter-comparison of ice sheet mass balance products from GRACE: ESA CCI Round Robin results

    DEFF Research Database (Denmark)

    Groth, A.; Horwath, M.; Horvath, A.

    -term satellite-based data products are generated for selected ECVs. Since ice sheet mass balance is an ECV parameter of highest interest, both the AIS_cci and the GIS_cci project will provide mass balance products based on satellite gravimetry data: (a) time series of monthly mass changes for individual drainage...... basins, and (b) gridded mass changes covering the entire ice sheet.Gravimetry Mass Balance (GMB) products are derived from data acquired by the GRACE (Gravity Recovery and Climate Experiment) mission. Although GRACE data have the advantage of being directly sensitive to mass changes, their limited...... drainage basins the GMB time series are compared to independent mass balance products based on satellite altimetry and firn densification information from a regional climate model. This inter-comparison has aided the algorithm definition for the operational ECV production....

  11. Radiation quality assurance intercomparison studies 1974--1975

    International Nuclear Information System (INIS)

    1975-10-01

    The Quality Assurance Branch of the Monitoring Systems Research and Development Division at the U.S. Environmental Protection Agency's Environmental Monitoring and Support Laboratory-Las Vegas prepares and distributes calibrated low-level radioactive solutions to Federal, State, and private laboratories involved in environmental radiation monitoring and surveillance. These solutions are used for both the calibration of counting instruments and chemical yield determinations. Since the laboratories using these samples must have confidence in their accuracy, the Quality Assurance Branch has instituted intercomparison studies with the National Bureau of Standards and with the Energy Research and Development Administration Health and Service Laboratory. The results of the studies conducted during 1974 and 1975 are described

  12. The third RAdiation transfer Model Intercomparison (RAMI) exercise: Documenting progress in canopy reflectance models

    NARCIS (Netherlands)

    Widlowski, J.L.; Taberner, M.; Pinty, B.; Bruniquel-Pinel, V.; Disney, M.I.; Fernandes, R.; Gastellu-Etchegorry, J.P.; Gobron, N.; Kuusk, A.; Lavergne, T.; LeBlanc, S.; Lewis, P.E.; Martin, E.; Mõttus, M.; North, P.R.J.; Qin, W.; Robustelli, M.; Rochdi, N.; Ruiloba, R.; Thompson, R.; Verhoef, W.; Verstraete, M.M.; Xie, D.

    2007-01-01

    [1] The Radiation Transfer Model Intercomparison ( RAMI) initiative benchmarks canopy reflectance models under well-controlled experimental conditions. Launched for the first time in 1999, this triennial community exercise encourages the systematic evaluation of canopy reflectance models on a

  13. Standards, intercomparisons and performance evaluations for low-level and environmental radionuclide mass spectrometry and atom counting

    International Nuclear Information System (INIS)

    Inn, K.G.W.; McCurdy, D.; Bell III, T.; Loesch, R.; Barss, N.M.; Morton, J.S.; Povinec, P.; Burns, K.; Henry, R.

    2001-01-01

    Because of the demand for higher sensitivity radionuclide measurements, atom counting technology will become an increasingly used modality in geo-and bio-studies, and process control operations. It is anticipated that requests, intercomparisons and performance evaluations services will surge in near future. In anticipation of such requests, the state-of-the-art needed to be assessed for proactive planning purposes. The results of a workshop focused on these issues indicated that there are several ongoing standards, intercomparisons and performance evaluations thrusts which are expected to expand in the future. Furthermore, new projects were planned and the Council on Ionizing Radiation Measurements and Standards (Public and Environmental Radiation Protection subcommittee) ws proposed as an information coordinator. (author)

  14. Intercomparison of the medium energy primary standards for X-ray exposure of NPL and ENEA, Italy

    International Nuclear Information System (INIS)

    Moretti, C.J.; Heaton, J.A.; Laitano, R.F.; Toni, M.P.

    1991-04-01

    An intercomparison between the primary standards of exposure for medium energy X-rays held by the National Physical Laboratory (NPL) and ENEA in Italy is described. The intercomparison, using four different transfer chambers, took place at NPL in December 1989 and at ENEA during March 1990. Measurements were made at four therapy-level qualities, with half value layers of 0.15, 0.5, 1.0 and 2.5 mm Cu (nominal generating voltages of 100, 135, 180 and 250 kV respectively). At the 2.5 mm Cu HVL quality the primary standards were found to agree to within about 0.8%; for the other three qualities the chambers differed by no more than 0.3%. (author)

  15. Evaluation of NAA laboratory results in inter-comparison on determination of trace elements in food and environmental samples

    International Nuclear Information System (INIS)

    Diah Dwiana Lestiani; Syukria Kurniawati; Natalia Adventini

    2012-01-01

    Inter-comparison program is a good tool for improving quality and to enhance the accuracy and precision of the analytical techniques. By participating in this program, laboratories could demonstrate their capability and ensuring the quality of analysis results generated by analytical laboratories. The Neutron Activation Analysis (NAA) laboratory at National Nuclear Energy Agency of Indonesia (BATAN), Nuclear Technology Center for Materials and Radiometry-PTNBR laboratory participated in inter-comparison tests organized by NAA working group. Inter-comparison BATAN 2009 was the third inter-laboratory analysis test within that project. The participating laboratories were asked to analyze for trace elements using neutron activation analysis as the primary technique. Three materials were distributed to the participants representing foodstuff, and environmental material samples. Samples were irradiated in rabbit facility of G.A. Siwabessy reactor with neutron flux ~ 10 13 n.cm -2 .s -1 , and counted with HPGe detector of gamma spectrometry. Several trace elements in these samples were detected. The accuracy and precision evaluation based on International Atomic Energy Agency (IAEA) criteria was applied. In this paper the PTNBR NAA laboratory results is evaluated. (author)

  16. A River Model Intercomparison Project in Preparation for SWOT

    Science.gov (United States)

    David, C. H.; Andreadis, K.; Famiglietti, J. S.; Beighley, E.; Boone, A. A.; Yamazaki, D.; Paiva, R. C. D.; Fleischmann, A. S.; Collischonn, W.; Fisher, C. K.; Kim, H.; Biancamaria, S.

    2017-12-01

    The Surface Water and Ocean Topography (SWOT) mission is currently scheduled to launch at the beginning of next decade. SWOT is expected to retrieve unprecedented measurements of water extent, elevation, and slope in the largest terrestrial water bodies. Such potential transformative information motivates the investigation of our ability to ingest the associated data into continental-scale models of terrestrial hydrology. In preparation for the expected SWOT observations, an inter-comparison of continental-scale river models is being performed. This comparison experiment focuses on four of the world's largest river basins: the Amazon, the Mississippi, the Niger, and the Saint-Lawrence. This ongoing project focuses on two main research questions: 1) How can we best prepare for the expected SWOT continental to global measurements before SWOT even flies?, and 2) What is the added value of including SWOT terrestrial measurements into global hydro models for enhancing our understanding of the terrestrial water cycle and the climate system? We present here the results of the second year of this project which now includes simulations from six numerical models of rivers over the Mississippi and sheds light on the implications of various modeling choices on simulation quality as well as on the potential impact of SWOT observations.

  17. EURADOS intercomparison exercise on Monte Carlo modelling of a medical linear accelerator.

    Science.gov (United States)

    Caccia, Barbara; Le Roy, Maïwenn; Blideanu, Valentin; Andenna, Claudio; Arun, Chairmadurai; Czarnecki, Damian; El Bardouni, Tarek; Gschwind, Régine; Huot, Nicolas; Martin, Eric; Zink, Klemens; Zoubair, Mariam; Price, Robert; de Carlan, Loïc

    2017-01-01

    In radiotherapy, Monte Carlo (MC) methods are considered a gold standard to calculate accurate dose distributions, particularly in heterogeneous tissues. EURADOS organized an international comparison with six participants applying different MC models to a real medical linear accelerator and to one homogeneous and four heterogeneous dosimetric phantoms. The aim of this exercise was to identify, by comparison of different MC models with a complete experimental dataset, critical aspects useful for MC users to build and calibrate a simulation and perform a dosimetric analysis. Results show on average a good agreement between simulated and experimental data. However, some significant differences have been observed especially in presence of heterogeneities. Moreover, the results are critically dependent on the different choices of the initial electron source parameters. This intercomparison allowed the participants to identify some critical issues in MC modelling of a medical linear accelerator. Therefore, the complete experimental dataset assembled for this intercomparison will be available to all the MC users, thus providing them an opportunity to build and calibrate a model for a real medical linear accelerator.

  18. International intercomparison of fluence of fast neutrons using 115In(n,γ) activation

    International Nuclear Information System (INIS)

    Lesiecki, H.; Cosack, M.

    1985-07-01

    The Physikalisch-Technische Bundesanstalt (PTB) has participated in an international intercomparison of fluence measurements of fast neutrons. This was organized under the auspices of the ''Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants (CCEMRI)'', Sect. 3 (Mesures Neutronique). The National Physical Laboratory (NPL), Teddington, UK volunteered to assume responsibility for the experimental realization and final evaluation. This report deals with the measurements performed at the PTB for the neutron fluence intercomparison at neutron energies of Esub(n) = 144 keV and 570 keV which was based on the 115 In(n,γ) 116 Insup(m) reaction. The count rate of a 4πβ-counter which had to be used to determine the activation of the In sample was to be compared with the neutron fluence by which the sample was irradiated. A description of the neutron production, the fluence determination, the 4πβ-counting, and the evaluation of the results will be given. (orig.) [de

  19. The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis

    International Nuclear Information System (INIS)

    Wieser, A.; Debuyst, R.; Fattibene, P.

    2005-01-01

    The objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 11 molars, which were cut into two halves. One half of each tooth was irradiated in a 60 Co beam to doses in the ranges of 30-100 mGy (5 samples), 100-300 mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose

  20. The IAEA worldwide intercomparison exercises (1990-1997). Determination of trace elements in marine sediments and biological samples

    International Nuclear Information System (INIS)

    Coquery, M.; Carvalho, F.P.; Azemard, S.; Horvat, M.

    1999-01-01

    Four major worldwide intercomparison exercises for the determination of trace elements in various environmental matrices were completed by the IAEA Marine Environment Laboratory since 1990: SD-M-2/TM, deep sea marine sediment; IAEA-350, tuna fish homogenate; IAEA-356, contaminated coastal sediment and IAEA-140, sea plant (Fucus sp.). These intercomparison exercises aim at enabling individual laboratories to monitor their performance. The results of these exercises allowed us to make an overall evaluation of the quality of data provided for environmental assessment and to identify the trends of analytical performance in the determination of trace elements over the years. The number of participants in each exercise varied between 68 and 130, and permits statistical evaluation of the performance for a number of elements. For each intercomparison exercise, the performance of the participant laboratories was assessed by comparing reported results with established reference values calculating 'Z-scores'. The results show that for each sample matrix, the values reported by some laboratories were far from satisfactory in the earlier exercises, in particular for Cd, Cr and Pb. Nevertheless, over time, a general improvement of performance can clearly be seen for all elements. Moreover, there was a noticeable increase in the number of laboratories with good performance in the two most recent exercises, observed both for biological and for sediment matrices. However, the determination of trace elements such as Cd, Cr, Pb and Hg in low level environmental samples still remains a major challenge to the analysts. For this reason and in order to assess the current performance of laboratories for low environmental levels of contaminants, the future intercomparison exercises will concentrate on low level sediment and fish samples

  1. Results of the regional intercomparison exercise for the determination of operational quantity Hp(10) in Latin America

    International Nuclear Information System (INIS)

    Saravi, M.; Zaretzky, A.; Lindner, C.; Diaz, J.; Walwyn, G.; Amorim, R.; De Souza, D.; Gregori, B.; Papadopulos, S.; Meghzifene, A.; Ferruz, P.; Suarez, R. C.

    2007-01-01

    Several intercomparison exercises were organised by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or inter-regional basis. In the Latin American region an intercomparison for the determination of the operational quantity H p (10) was completed mid-2004, as a follow-up to previous exercises carried out during the 1990's. Eighteen individual external monitoring services from nineteen Member States participated in the first phase. The second phase grouped 15 services that had participated in the first phase. Dosemeter irradiations in photon beams were done by four Secondary Standard Dosimetry Laboratories (SSDLs) of the region. The preparation of this exercises involved an audit by the IAEA SSDL, where reference irradiations were provided to all participants for verification of their systems. During the first phase (2002-2003) only 9 out of 18 services met the performance requirements for such monitoring services. Necessary corrective actions and procedure verification were implemented. During the second phase (2004) 11 out of 15 services fulfilled the performance criteria. This intercomparison shows that there has been improvement in the second phase and most participants demonstrated a satisfactory performance of the quantity tested. (authors)

  2. TLD Intercomparison in accelerators for radiotherapy in three Latin american countries

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez, M.A.; Picon, C.; Castellanos, E.; Plazas, M.C.; Murcia, G.; Archundia, L.

    1998-01-01

    In Radiotherapy one of the objectives is to establish and to give follow up to quality assurance programs which make sure that the doses administered to the patients with cancer are a high probability of a success in external radiation. Likewise, one of the present preoccupations of the United Nations Agencies as well as the International Atomic Energy Agency and the Pan-American Health Organization is the optimal employment of the radiations in the treatment of cancer patients since the administered dose in Radiotherapy suffers considerable variations by the lack of quality assurance programs. The use of Electron linear accelerators requires a program of quality assurance that includes expert personnel, equipment and adequate facilities. The more used methodology for the dosimetry calibration and characterization of X-ray beams and high energy electrons for radiotherapy use is using a ionization chamber dosemeter calibrated in a regional secondary standardization laboratory. However, to establish and give follow up to the quality assurance programs it is necessary the dosimetric intercomparison through TLD. In this study it was designed plastic phantoms with TLD crystals and it was made its characterization to realize an absorbed dose analysis in the crystals exposed at X-ray beams 6 MV and high energy electrons 10 and 12 MeV to standardize the dosimetric procedures and proceeding to realize an International Pilot intercomparison of absorbed doses in TLD crystals in three Latin American countries: Mexico, Peru and Colombia with the participation of accelerators of five different institutions. The found results show that the majority of the measured doses with TLD in the different accelerators were in the 0.95-1.05 range though it had two cases outside of this range. The use of the phantoms with TLD crystals shows that they are of excellent aid to make analysis of the doses administered to the patients and an intercomparison of results to standardize procedures at

  3. ABACC's laboratory intercomparison program

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Esteban, Adolfo; Almeida, Silvio G. de; Araujo, Radier M. de; Rocha, Zildete

    1996-01-01

    A Laboratory Intercomparison Program involving Brazilian and Argentine laboratories, with the special participation of New Brunswick Laboratory - DOE and IAEA Seibersdorf Safeguards Laboratory, was implanted by ABACC having as main purpose to qualify a network to provide analytical services to this Agency on its role as administrator of the Common System of Accountability and Control of Nuclear Materials. For the first round robin of this Program, 15 laboratories were invited to perform elemental analysis on UO 2 samples, by using any desired method. Thirteen confirmed the participation and 10 reported the results. After an evaluation of the results by using a Two-Way Variance Analysis applied to a nested error model, it was found that 5 of them deviate less than 0.1% from the reference value established for the UO 2 uranium contents, being thus situated within the limits adopted for the target values, while the remaining ones reach a maximal deviation of 0.44%. The outcome of this evaluation, was sent to the laboratories, providing them with a feedback to improve their performance by applying corrective actions to the detected sources of errors or bias related to the methods techniques and procedures. (author)

  4. Intercomparison of enriched stable isotope reference materials for medical and biological studies

    International Nuclear Information System (INIS)

    Parr, R.M.; Clements, S.A.

    1991-01-01

    This report summarizes the results of an intercomparison exercise organized by the IAEA during the latter part of 1988 and 1989. Data are presented for 13 different kinds of enriched stable isotope reference material containing 2 H, 13 C, 15 N and 18 O. Results were submitted by forty participants in twenty countries. 2 refs, 13 figs, 18 tabs

  5. Model Evaluation and Uncertainty in Agricultural Impacts Assessments: Results and Strategies from the Agricultural Model Intercomparison and Improvement Project (AgMIP)

    Science.gov (United States)

    Rosenzweig, C.; Hatfield, J.; Jones, J. W.; Ruane, A. C.

    2012-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is an international effort to assess the state of global agricultural modeling and to understand climate impacts on the agricultural sector. AgMIP connects the climate science, crop modeling, and agricultural economic modeling communities to generate probabilistic projections of current and future climate impacts. The goals of AgMIP are to improve substantially the characterization of risk of hunger and world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. This presentation will describe the general approach of AgMIP, highlight AgMIP efforts to evaluate climate, crop, and economic models, and discuss AgMIP uncertainty assessments. Model evaluation efforts will be outlined using examples from various facets of AgMIP, including climate scenario generation, the wheat crop model intercomparison, and the global agricultural economics model intercomparison being led in collaboration with the Inter-Sectoral Impact Model Intercomparison Project (ISI-MIP). Strategies developed to quantify uncertainty in each component of AgMIP, as well as the propagation of uncertainty through the climate-crop-economic modeling framework, will be detailed and preliminary uncertainty assessments that highlight crucial areas requiring improved models and data collection will be introduced.

  6. Report on the intercomparison for the determination of trace elements in Lake Sediment (SL-1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-02-01

    The determination of trace element concentrations including those of the rare-earths in geological samples has gained much importance during the past decade. Knowledge of the concentrations of specific elements and of their ratios have proved essential for the understanding of the development of geological strata. With increasing use of instruments in analysis, reference samples have become essential for their calibration and various international organizations have issued reference materials to monitor precision and accuracy in chemical determinations. The IAEA has in the past organized several intercomparisons and prepared reference samples of geochemical materials. The present report deals with a recent intercomparison on the determination of trace elements in Lake Sediment (Sl-1) carried out in 1977-1978 and involving the participation of 43 institutes who returned a total of 2535 individual results on 43 elements.

  7. ENDFIC - A program for indexing and intercomparison of ENDFs

    International Nuclear Information System (INIS)

    Gopalakrishnan, V.; Devan, K.

    1995-01-01

    The program ENDFIC, a nuclear data utility program in FORTRAN, was written under contract on 'Indexing and Intercomparison Programme of Evaluated Nuclear Data Files' (No. 7866/RB/TC), between Indira Gandhi Centre for Atomic Research, Kalpakkam, and the International Atomic Energy Agency, Vienna. The program can be used for the following two activities: i. INFO activity: to find from a given ENDF/B formatted evaluated nuclear data library, information regarding the contents of the library; ii. COMP activity: to do comparison of cross sections from several given ENDF libraries. 1 ref

  8. Quality control in low-level radionuclide analysis. Results of recent intercomparisons and programme for 1979/80 of the International Atomic Energy Agency

    Energy Technology Data Exchange (ETDEWEB)

    Suschny, O; Dybczynski, R; Tugsavul, A

    1979-05-01

    Several summary reports on the IAEA's analytical quality control programme have been issued in the past. A report mapping out areas of common interest with the ICRM has been presented to the Paris meeting of ICRM's low-level measurement techniques group in 1976 and subsequently published in environment international. General descriptions of the programme as it has developed in the past 15 years can be found in these publications, in addition detailed results of intercomparisons have been published in IAEA reports and in the open literature (about 30 publications), they are too numerous for citation here. This paper presents discussion of the results of recent intercomparisons of low level radionuclide determinations followed by a presentation of our schedule of distribution of intercomparison and reference materials for 1979 and 80.

  9. New Results from the Geoengineering Model Intercomparison Project (GeoMIP)

    Science.gov (United States)

    Robock, A.; Kravitz, B.

    2013-12-01

    The Geoengineering Model Intercomparison Project (GeoMIP) was designed to determine robust climate system model responses to Solar Radiation Management (SRM). While mitigation (reducing greenhouse gases emissions) is the most effective way of reducing future climate change, SRM (the deliberate modification of incoming solar radiation) has been proposed as a means of temporarily alleviating some of the effects of global warming. For society to make informed decisions as to whether SRM should ever be implemented, information is needed on the benefits, risks, and side effects, and GeoMIP seeks to aid in that endeavor. GeoMIP has organized four standardized climate model simulations involving reduction of insolation or increased amounts of stratospheric sulfate aerosols to counteract increasing greenhouse gases. Thirteen comprehensive atmosphere-ocean general circulation models have participated in the project so far. GeoMIP is a 'CMIP Coordinated Experiment' as part of the Climate Model Intercomparison Project 5 (CMIP5) and has been endorsed by SPARC (Stratosphere-troposphere Processes And their Role in Climate). GeoMIP has held three international workshops and has produced a number of recent journal articles. GeoMIP has found that if increasing greenhouse gases could be counteracted with insolation reduction, the global average temperature could be kept constant, but global average precipitation would reduce, particularly in summer monsoon regions around the world. Temperature changes would also not be uniform. The tropics would cool, but high latitudes would warm, with continuing, but reduced sea ice and ice sheet melting. Temperature extremes would still increase, but not as much as without SRM. If SRM were halted all at once, there would be rapid temperature and precipitation increases at 5-10 times the rates from gradual global warming. SRM combined with CO2 fertilization would have small impacts on rice production in China, but would increase maize production

  10. DOE radiological calibrations intercomparison program: Results of fiscal year 1986

    International Nuclear Information System (INIS)

    Cummings, F.M.; Roberson, P.L.; McDonald, J.C.

    1987-05-01

    The Department of Energy Radiological Calibration Intercomparison Program was initiated in January 1986, under the research portion of the DOE Laboratory Accreditation Program. The program operates via the exchange of transfer standards, consisting of instrument sets and standard secondary beta sources. There are two instrument sets and the scheduled use has been staggered such that one set is available for use during each month. One set of secondary standard beta sources is available for use bimonthly. During the 1986 fiscal year, five laboratories used the instrument sets and three laboratories used the beta source set. Results were reported for all the measurements. The average and one standard deviation of the ratios of participant results to Pacific Northwest Laboratory calibration values were 1.12 +- 0.17 for gamma measurements. Those ratios for the gamma measurements varied from 0.98 to 3.06. The larger differences of results from measurements performed at two facilities were directly attributable to unfamiliarity with the intercomparison instruments. The average and one standard deviation of the ratios of participant results to PNL calibration values obtained using the secondary 90 Sr beta source was 1.02 +- 0.05, which is well within measurement uncertainties. The one participant who performed measurements using 147 Pm and 204 Tl sources obtained ratios of 0.68 and 1.11, respectively. No measurements were performed using neutron or x-ray sources

  11. Second radiocarbon intercomparison program for the Chauvet-Pont d'Arc cave, Ardeche, France

    International Nuclear Information System (INIS)

    Quiles, A.; Valladas, H.; Kaltnecker, E.; Geneste, J.M.; Clottes, J.; Berthier, B.; Delque-Kolic, E.; Dumoulin, J.P.

    2014-01-01

    The Chauvet-Pont d'Arc Cave is one of the most important sites for the study of the earliest manifestations and development of prehistoric art at the beginning of the Upper Paleolithic. Different dating techniques have been performed thus far (AMS 14 C, U/Th TIMS, 36 Cl dating) to model the chronological framework of this decorated cave. The cave yielded several large charcoal fragments, which enabled the opportunity for obtaining multiple dates; thus, a First Radiocarbon Intercomparison Program (FIP) was initiated in 2004 using three charcoal pieces. The FIP demonstrated that those cross-dated samples belonged to a time period associated with the first human occupation. One of the statistical interests of an intercomparison program is to reduce the uncertainty on the sample age; thus, to further assess the accuracy of the chronological framework, the Second Intercomparison Program (SIP) involving 10 international 14 C laboratories was carried out on two pieces of charcoal found inside two hearth structures of the Galerie des Megaceros. Each laboratory used its own pretreatment and AMS facilities. In total, 21 and 22 measurements were performed, respectively, which yielded consistent results averaging ∼32 ka BP. Two strategies have currently been developed to identify statistical outliers and to deal with them; both lead to quasi-identical calibrated combined densities. Finally, the new results were compared with those of the FIP, leading to the important conclusion that five different samples from at least three different hearth structures give really tightened temporal densities, associated with one short human occupation in the Galerie des Megaceros. (authors)

  12. Measurement of environment and food products radioactivity: the intercomparisons organised by OPRI

    International Nuclear Information System (INIS)

    Anon.

    2001-01-01

    For the laboratories that measure the radioactivity of environment and foods, the analysis quality is essential. The test of intercomparison is unrivaled to check it. Since 1970, the sub-direction of sanitary impact organizes this kind of test at the French, European and International levels. Its objective is to contribute to the persistent improvement of participating laboratories analysis. (N.C.)

  13. Exercise of Intercomparison on characterization of graphite irradiated: CW-RRT

    International Nuclear Information System (INIS)

    Pina, G.; Rodriguez, M.; Lara, E.; Magro, E.

    2014-01-01

    Knowledge of inventory of irradiated graphite (i-graphite) of nuclear reactors is a critical parameter for the proper management of waste. For this reason it is of paramount importance have access to reliable analytical methodologies to provide accurate results through radiochemical procedures specifics. La reliability of the result depends on both its precision and the accuracy obtained. this requires specific tasks compared to other methods, such as the extent of an array reference or conducting intercomparison exercises between laboratories. (Author)

  14. The measurement of activity-weighted size distributions of radon progeny: methods and laboratory intercomparison studies

    International Nuclear Information System (INIS)

    Hopke, P.K.; Strydom, R.; Ramamurthi, M.; Knutson, E.O.; Tu, K.W.; Scofield, P.; Holub, R.F.; Cheng, Y.S.; Su, Y.F.; Winklmayr, W.

    1992-01-01

    Over the past 5 y, there have been significant improvements in measurement of activity-weighted size distributions of airborne radon decay products. The modification of screen diffusion batteries to incorporate multiple screens of differing mesh number, called graded screen arrays, have permitted improved size resolution below 10 nm such that the size distributions can now be determined down to molecular sized activities (0.5 nm). In order to ascertain the utility and reliability of such systems, several intercomparison tests have been performed in a 2.4 m3 radon chamber in which particles of varying size have been produced by introducing SO2 and H2O along with the radon to the chamber. In April 1988, intercomparison studies were performed between direct measurements of the activity-weighted size distributions as measured by graded screen arrays and an indirect measurement of the distribution obtained by measuring the number size distribution with a differential mobility analyzer and multiplying by the theoretical attachment rate. Good agreement was obtained in these measurements. A second set of intercomparison studies among a number of groups with graded screen array systems was made in April 1989 with the objective of resolving spectral structure below 10 nm. Again, generally good agreement among the various groups was obtained although some differences were noted. It is thus concluded that such systems can be constructed and can be useful in making routine measurements of activity-weighted size distributions with reasonable confidence in the results obtained

  15. Intercomparison of analysis methods for seismically isolated nuclear structures. Papers and working materials presented at the 3. research coordination meeting

    International Nuclear Information System (INIS)

    1998-01-01

    The Coordinated research program on Intercomparison of analysis methods for seismically isolated nuclear structures involved participants from Italy, Japan, Republic of Korea, Russia, United Kingdom, USA, EC. The purpose of the meeting was to review the progress on the finite element prediction of the force-deformation behaviour of seismic isolators and to discuss the first set of analytical results for the prediction of the response of base-oscillated structures to earthquake inputs. The intercomparison of predictions of bearing behaviour has identified important unexpected issues requiring deeper investigation

  16. Results of the PEP`93 intercomparison of reference cell calibrations and newer technology performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R.; Emery, K. [National Renewable Energy Lab., Golden, CO (United States); Anevsky, S. [All-Union Research Inst. for Optophysical Measurements, Moscow (Russian Federation)] [and others

    1996-05-01

    This paper presents the results of an international intercomparison of photovoltaic (PV) performance measurements and calibrations. The intercomparison, which was organized and operated by a group of experts representing national laboratories from across the globe (i.e., the authors of this paper), was accomplished by circulating two sample sets. One set consisted of twenty silicon reference cells that would, hopefully, form the basis of an international PV reference scale. A qualification procedure applied to the calibration results gave average calibration numbers with an overall standard deviation of less than 2% for the entire set. The second set was assembled from a wide range of newer technologies that present unique problems for PV measurements. As might be expected, these results showed much larger differences among laboratories. Methods were then identified that should be used to measure such devices, along with problems to avoid.

  17. Intercomparisons to establish official methods for the detection of irradiated foods

    International Nuclear Information System (INIS)

    Spiegelberg, A.; Schulzki, G.; Bogl, K.W.; Schreiber, G.A.

    1994-01-01

    Irradiation of food for the purpose of extension of shelf life, control of microbial load, reduction of pathogenic microorganisms and disinfection is considered by many consumers with suspicion. Our studies concentrate on the establishment of official methods suitable for routine control measurements. Special emphasis is given to following methods: thermoluminescence (TL) analysis of minerals isolated from various foods, like spices, herbs, dried vegetables, teas, fruits or vegetables; electron spin resonance (ESR) spectroscopy of food components or whole foods that have a low water content, such as bones, first bones, shells, peels seeds, pips or dried fruits and detection of volatile hydrocarbons in the lipid fraction of fat containing food by gas-chromatographic analysis (GC). All three methods have been tested on a variety of foods within large scale intercomparisons between German food controlling laboratories. In Germany official methods could be established for detection of irradiated spices, spice mixtures and fruits by TL, of meat with bones, nuts and fish by ESR, and of chicken, pork and beef meat by GC. The latest intercomparisons have tested these methods for the detection of potatoes and shrimps by TL, of red paper and shrimps by ESR and of mangoes, papayas, avocados and cheese - by GC. Results were presented. (author)

  18. Participation of the regional reference center for dosimetry of Argentina in the personnel dosimetry intercomparison for Latin America

    International Nuclear Information System (INIS)

    Alvarez, P.; Lindner, C.; Montano, R.G.; Saravi, M.

    1998-01-01

    Full text: A Regional Personnel Dosimetry Intercomparison was organized in the Regional Reference Center for Dosimetry (CRRD), in agreement with the International Atomic Energy Agency (IAEA) and the Nuclear Regulatory Authority (ARN), with the participation of 9 countries of Latin America. For dosimeter irradiations, X-ray, 60 Co γ-ray and 137 Cs γ-ray beams were used during the intercomparison. The air kerma rate was measured with the Secondary Standard NE 2560 and NE 2561 ionisation chamber. In compliance with ISO 4037 guideline, the wide spectrum series W60, W110 and W200 for the X-ray irradiations were chosen, determining their quality by the HVL method. Prior to the intercomparison, these beams were checked by the Physikalish Technische Bundesanstalt (PTB) using thermoluminescence dosimeters 'pill box', which were irradiated in air and in ICRU phantom. As result of this check, only one 'X ray beam got a deviation of 7%, while the rest of them were less than 3%. Periodic checks of the beams by a Primary Standard Dosimetry Laboratory such as PTB give reliability to the irradiations performed by this CRRD. (author) [es

  19. Report on the intercomparison run and certified reference material IAEA-381. Radionuclides in Irish sea water

    International Nuclear Information System (INIS)

    Povinec, P.P.; Pham, M.K.; Ballestra, S.

    1999-01-01

    The accurate and precise determinations of radionuclide concentrations in marine samples are important aspects of marine radioactivity assessments and the use of radionuclides in studies of oceanographic processes. To address the problem of data quality, the IAEA Marine Environment Laboratory (MEL) in Monaco has conducted intercomparison exercises on radionuclides in marine samples for many years as part of its contribution to the IAEA's programme of Analytical Quality Control Services (AQCS). For this intercomparison exercise, the Federal Maritime and Hydrographic Agency, Hamburg, Germany (BSH) collected sea water from the Irish Sea in 1993. IAEA-MEL distributed sample aliquots during 1995-1996 for intercomparison of anthropogenic and natural radionuclides. About 80 laboratories world-wide were approached with a questionnaire for participation. Of these, only 43 accepted the invitation because of financial constraints (the participating laboratories were asked to pay transportation expenses). As the sample was collected in the Irish Sea, elevated levels of anthropogenic radionuclides were expected due to discharges from the Sellafield reprocessing plant. Participants were informed that the expected activities for anthropogenic radionuclides would be in the ranges: 90 Sr: 50-500 Bq/kg, 137 Cs: 100-1000 Bq/kg, 239+240 Pu: 1-50Bq/kg, 241 Am: 1-50Bq/kg. This report describes the results obtained from 28 laboratories on anthropogenic and natural radionuclide determinations in sea water

  20. GLM Proxy Data Generation: Methods for Stroke/Pulse Level Inter-Comparison of Ground-Based Lightning Reference Networks

    Science.gov (United States)

    Cummins, Kenneth L.; Carey, Lawrence D.; Schultz, Christopher J.; Bateman, Monte G.; Cecil, Daniel J.; Rudlosky, Scott D.; Petersen, Walter Arthur; Blakeslee, Richard J.; Goodman, Steven J.

    2011-01-01

    In order to produce useful proxy data for the GOES-R Geostationary Lightning Mapper (GLM) in regions not covered by VLF lightning mapping systems, we intend to employ data produced by ground-based (regional or global) VLF/LF lightning detection networks. Before using these data in GLM Risk Reduction tasks, it is necessary to have a quantitative understanding of the performance of these networks, in terms of CG flash/stroke DE, cloud flash/pulse DE, location accuracy, and CLD/CG classification error. This information is being obtained through inter-comparison with LMAs and well-quantified VLF/LF lightning networks. One of our approaches is to compare "bulk" counting statistics on the spatial scale of convective cells, in order to both quantify relative performance and observe variations in cell-based temporal trends provided by each network. In addition, we are using microsecond-level stroke/pulse time correlation to facilitate detailed inter-comparisons at a more-fundamental level. The current development status of our ground-based inter-comparison and evaluation tools will be presented, and performance metrics will be discussed through a comparison of Vaisala s Global Lightning Dataset (GLD360) with the NLDN at locations within and outside the U.S.

  1. Inter-comparison of lidar and ceilometer retrievals for aerosol and Planetary Boundary Layer profiling over Athens, Greece

    Directory of Open Access Journals (Sweden)

    G. Tsaknakis

    2011-06-01

    Full Text Available This study presents an inter-comparison of two active remote sensors (lidar and ceilometer to determine the mixing layer height and structure of the Planetary Boundary Layer (PBL and to retrieve tropospheric aerosol vertical profiles over Athens, Greece. This inter-comparison was performed under various strongly different aerosol loads/types (urban air pollution, biomass burning and Saharan dust event, implementing two different lidar systems (one portable Raymetrics S.A. lidar system running at 355 nm and one multi-wavelength Raman lidar system running at 355 nm, 532 nm and 1064 nm and one CL31 Vaisala S.A. ceilometer (running at 910 nm. Spectral conversions of the ceilometer's data were performed using the Ångström exponent estimated by ultraviolet multi-filter radiometer (UV-MFR measurements. The inter-comparison was based on two parameters: the mixing layer height determined by the presence of the suspended aerosols and the attenuated backscatter coefficient. Additionally, radiosonde data were used to derive the PBL height. In general, a good agreement was found between the ceilometer and the lidar techniques in both inter-compared parameters in the height range from 500 m to 5000 m, while the limitations of each instrument are also examined.

  2. IDEAS/IAEA intercomparison exercise on internal dose assessment. Intercomparison exercise on Internal Dose Assessment performed jointly by the International Atomic Energy Agency and the IDEAS project (''General Guidelines for the Evaluation of Incorporation Monitoring Data'', carried out within the 5th EU Framework Programme)

    International Nuclear Information System (INIS)

    Hurtgen, C.; Andrasi, A.; Bailey, M.R.

    2005-10-01

    There were several intercomparison exercises organized already at national and international levels for the assessment of occupational exposure due to intakes of radionuclides. These intercomparison exercises revealed significant differences in the approaches, methods and assumptions, and consequently in the results. In the frame of the IDEAS project .General Guidelines for the Evaluation of Incorporation Monitoring Data., launched in the 5th EU Framework Programme, a new intercomparison exercise was performed. Originally it was planned to organise this intercomparison exercise on a European scale. Because of the relevance of the issue for the whole community of internal dosimetrists, however, it was decided to organise the exercise on a broader scale together with the IAEA. This new intercomparison exercise especially focuses on the effect of the guidelines for harmonisation of internal dosimetry. In addition it also consider the following aspects: - to provide possibilities for the participating laboratories to check the quality of their internal dose assessment methods in applying the recent ICRP recommendations (new respiratory tract model etc.); - to compare different approaches in interpretation of internal contamination monitoring data; - to quantify the differences in internal dose assessment based on the new guidelines or on other procedures, respectively; - to provide some figures of the influence of the input parameters on the monitoring results and - to provide a broad forum for information exchange. Several cases have been selected for the exercise with the aim to cover a wide range of practices in the nuclear fuel cycle and medical applications. The case were: 1. Acute intake of HTO; 2. Acute inhalation of fission products 137 Cs and 90 Sr; 3. Intake of 60 Co; 4. Repeated intakes of 131 I; 5. Intake of enriched uranium; 6. Single intake of Pu radionuclides and 241 Am. A web-based approach was being used for the presentation of the cases, collection of

  3. IAEA/ WHO TLD postal dose intercomparison results in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Bhuiyan, N.U.; Rahman, S.

    2001-01-01

    Full text: For the accurate delivery of prescribed dose to the patients, high precision and accuracy in radiation dosimetry is required. The hospital/medical physicist is responsible for the accurate delivery of whole planned radiation doses to the patients prescribed by the radio therapist. The proper delivery of radiation doses depends upon the accurate output measurements of doses from the therapy machines. In Bangladesh, only six 60 Co units and five deep therapy machines are in use. Some more are expected to be installed soon. Still in 2001, none of the Government radiotherapy centers in Bangladesh was properly equipped with medical physicists as well as radiotherapy dosimetry equipment. Bangladesh Atomic Energy Commission (BAEC) is responsible for radiation safety in Bangladesh and BAEC has assigned Secondary Standard Dosimetry Laboratory (SSDL) of Bangladesh for providing dosimetry calibration to all radiotherapy centers in Bangladesh. The output measurements of therapy machines are performed once in a year by SSDL and the results are compared by participating in the annual TLD postal dose intercomparison program organized by IAEA/WHO SSDL Network. The absorbed dose to water is determined using IAEA dosimetry protocol (TRS 277 and 381) and water phantom of size 30 x 30 x 30 cm 3 , The measurements of SSDL are traceable to NPL of UK. The accuracy achieved in SSDL, Bangladesh has been found better than ± 3.5%, which is within the prescribed limit of dosimetry standard of IAEA. The methodology of output dose measurements in different radiotherapy centers in Bangladesh is described along with the IAEA/WHO intercomparison results

  4. IPRT polarized radiative transfer model intercomparison project - Three-dimensional test cases (phase B)

    Science.gov (United States)

    Emde, Claudia; Barlakas, Vasileios; Cornet, Céline; Evans, Frank; Wang, Zhen; Labonotte, Laurent C.; Macke, Andreas; Mayer, Bernhard; Wendisch, Manfred

    2018-04-01

    Initially unpolarized solar radiation becomes polarized by scattering in the Earth's atmosphere. In particular molecular scattering (Rayleigh scattering) polarizes electromagnetic radiation, but also scattering of radiation at aerosols, cloud droplets (Mie scattering) and ice crystals polarizes. Each atmospheric constituent produces a characteristic polarization signal, thus spectro-polarimetric measurements are frequently employed for remote sensing of aerosol and cloud properties. Retrieval algorithms require efficient radiative transfer models. Usually, these apply the plane-parallel approximation (PPA), assuming that the atmosphere consists of horizontally homogeneous layers. This allows to solve the vector radiative transfer equation (VRTE) efficiently. For remote sensing applications, the radiance is considered constant over the instantaneous field-of-view of the instrument and each sensor element is treated independently in plane-parallel approximation, neglecting horizontal radiation transport between adjacent pixels (Independent Pixel Approximation, IPA). In order to estimate the errors due to the IPA approximation, three-dimensional (3D) vector radiative transfer models are required. So far, only a few such models exist. Therefore, the International Polarized Radiative Transfer (IPRT) working group of the International Radiation Commission (IRC) has initiated a model intercomparison project in order to provide benchmark results for polarized radiative transfer. The group has already performed an intercomparison for one-dimensional (1D) multi-layer test cases [phase A, 1]. This paper presents the continuation of the intercomparison project (phase B) for 2D and 3D test cases: a step cloud, a cubic cloud, and a more realistic scenario including a 3D cloud field generated by a Large Eddy Simulation (LES) model and typical background aerosols. The commonly established benchmark results for 3D polarized radiative transfer are available at the IPRT website (http

  5. Report on intercomparison V-8 of the determination of trace elements in rye flour

    International Nuclear Information System (INIS)

    Pszonicki, L.; Veglia, A.; Dybczynski, R.; Suschny, O.

    1982-01-01

    The participants were requested to determine as many elements as they could from among the following 29: As, Be, Ca, Cd, Cl, Co, Cr, Cu, F, Fe, Ga, Hg, I, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Si, Sn, Tl, U, V and Zn. While six of these elements (Be, Ga, Sn, Tl, U, V) were not determined by any laboratory, some participants on the other hand determined several elements which had not been ordered for such as As, Al, Au, Ba, Br, Cs, Eu, La, N, Rb, S, Sc, Sr, Ti and Y. In total, 34 laboratories submitted results of 1,207 individual determinations (301 laboratory means) on 38 elements. The methods most often employed in this intercomparison were neutron activation analysis (47% of all results) and atomic absorption (20%). The results of the intercomparison demonstrated again the difficulties in the determination of trace elements in organic materials. The agreement between participating laboratories was in general poor

  6. The Brazilian National Intercomparison Program (PNI/IRD/CNEN): evaluation of 15 years of data

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Vianna, Maria Elizabeth Couto M.; Oliveira, Antonio Eduardo de; Ferreira, Ana Cristina; Braganca, Maura Julia C.; Clain, Almir Faria; Quelvia de Faria, Rute

    2006-01-01

    The Instituto de Radioprotecao e Dosimetria has been coordinating the National Intercomparison Program (PNI) for 15 years, from 1991 to 2005. The objective is to evaluate the analytical performance of the laboratories in low-level activity concentration radionuclide assays in environmental samples. This work presents an evaluation of PNI data from 42 intercomparison runs, which distributed to 22 Brazilian laboratories 2511 samples evaluating 5768 radionuclide assays involving 32 radionuclides in the period from 1991 to 2004. The laboratory performance was evaluated using the Normalized Standard Deviation used by the U.S. EPA. For comparison aims, the Normalized Deviation, used by BIPM was also applied. Laboratory performance were grouped and evaluated in three periods of 5 years each. The first period shows, an average value of good performance of 71.2%, the second shows an average of 78.6% and the last an average of 82.3%. Performance for each kind of radionuclide is also presented

  7. First national intercomparison of personal dosimetry for dosimetry service providers in paec

    International Nuclear Information System (INIS)

    Akhter, J.; Ahmed, S.S.

    2006-12-01

    Health Physics Division, PINSTECH, has conducted an intercomparison exercise for PAEC organizations which are responsible for providing personal dosimetry services for the assessment of occupational doses of radiation workers. The exercise was on voluntary basis and it was designed to harmonize the procedure of individual dose monitoring techniques in terms of new ICRP operational quantities of personal dose equivalent Hp (10) for photons. Cobalt-60 and Cesium-137 protection level sources were used for irradiation. The dosimeters were exposed to radiation in the range of 0.46 to 24.20 mSv. Irradiations were performed in Secondary Standard Dosimetry Laboratory (SSDL) at HPD, PINSTECH according to IAEA/WHO standards. The performance of the participating laboratories was judged by trumpet curve that provides the acceptable limits on overall accuracy for occupational dose monitoring at 95% confidence level according to international standards. The response of measured dose/standard true dose (Hm/Ht lies in the range of 0.66 to 1.11 for 60CO and 0.84 to 1.17 for 137CS. This report describes the procedure and results of the intercomparison exercise. (author)

  8. GEO-LEO reflectance band inter-comparison with BRDF and atmospheric scattering corrections

    Science.gov (United States)

    Chang, Tiejun; Xiong, Xiaoxiong Jack; Keller, Graziela; Wu, Xiangqian

    2017-09-01

    The inter-comparison of the reflective solar bands between the instruments onboard a geostationary orbit satellite and onboard a low Earth orbit satellite is very helpful to assess their calibration consistency. GOES-R was launched on November 19, 2016 and Himawari 8 was launched October 7, 2014. Unlike the previous GOES instruments, the Advanced Baseline Imager on GOES-16 (GOES-R became GOES-16 after November 29 when it reached orbit) and the Advanced Himawari Imager (AHI) on Himawari 8 have onboard calibrators for the reflective solar bands. The assessment of calibration is important for their product quality enhancement. MODIS and VIIRS, with their stringent calibration requirements and excellent on-orbit calibration performance, provide good references. The simultaneous nadir overpass (SNO) and ray-matching are widely used inter-comparison methods for reflective solar bands. In this work, the inter-comparisons are performed over a pseudo-invariant target. The use of stable and uniform calibration sites provides comparison with appropriate reflectance level, accurate adjustment for band spectral coverage difference, reduction of impact from pixel mismatching, and consistency of BRDF and atmospheric correction. The site in this work is a desert site in Australia (latitude -29.0 South; longitude 139.8 East). Due to the difference in solar and view angles, two corrections are applied to have comparable measurements. The first is the atmospheric scattering correction. The satellite sensor measurements are top of atmosphere reflectance. The scattering, especially Rayleigh scattering, should be removed allowing the ground reflectance to be derived. Secondly, the angle differences magnify the BRDF effect. The ground reflectance should be corrected to have comparable measurements. The atmospheric correction is performed using a vector version of the Second Simulation of a Satellite Signal in the Solar Spectrum modeling and BRDF correction is performed using a semi

  9. Intercomparison of model simulations of mixed-phase clouds observed during the ARM Mixed-Phase Arctic Cloud Experiment. Part I: Single layer cloud

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Stephen A.; McCoy, Renata B.; Morrison, Hugh; Ackerman, Andrew S.; Avramov, Alexander; de Boer, Gijs; Chen, Mingxuan; Cole, Jason N.S.; Del Genio, Anthony D.; Falk, Michael; Foster, Michael J.; Fridlind, Ann; Golaz, Jean-Christophe; Hashino, Tempei; Harrington, Jerry Y.; Hoose, Corinna; Khairoutdinov, Marat F.; Larson, Vincent E.; Liu, Xiaohong; Luo, Yali; McFarquhar, Greg M.; Menon, Surabi; Neggers, Roel A. J.; Park, Sungsu; Poellot, Michael R.; Schmidt, Jerome M.; Sednev, Igor; Shipway, Ben J.; Shupe, Matthew D.; Spangenberg, Douglas A.; Sud, Yogesh C.; Turner, David D.; Veron, Dana E.; von Salzen, Knut; Walker, Gregory K.; Wang, Zhien; Wolf, Audrey B.; Xie, Shaocheng; Xu, Kuan-Man; Yang, Fanglin; Zhang, Gong

    2009-02-02

    Results are presented from an intercomparison of single-column and cloud-resolving model simulations of a cold-air outbreak mixed-phase stratocumulus cloud observed during the Atmospheric Radiation Measurement (ARM) program's Mixed-Phase Arctic Cloud Experiment. The observed cloud occurred in a well-mixed boundary layer with a cloud top temperature of -15 C. The observed average liquid water path of around 160 g m{sup -2} was about two-thirds of the adiabatic value and much greater than the average mass of ice crystal precipitation which when integrated from the surface to cloud top was around 15 g m{sup -2}. The simulations were performed by seventeen single-column models (SCMs) and nine cloud-resolving models (CRMs). While the simulated ice water path is generally consistent with the observed values, the median SCM and CRM liquid water path is a factor of three smaller than observed. Results from a sensitivity study in which models removed ice microphysics suggest that in many models the interaction between liquid and ice-phase microphysics is responsible for the large model underestimate of liquid water path. Despite this general underestimate, the simulated liquid and ice water paths of several models are consistent with the observed values. Furthermore, there is evidence that models with more sophisticated microphysics simulate liquid and ice water paths that are in better agreement with the observed values, although considerable scatter is also present. Although no single factor guarantees a good simulation, these results emphasize the need for improvement in the model representation of mixed-phase microphysics.

  10. Present and future activities of the IAEA on internal dosimetry: Lessons learned from international intercomparisons

    International Nuclear Information System (INIS)

    Cruz Suarez, R.; Gustafsson, M.; Mrabit, K.

    2003-01-01

    The International Atomic Energy Agency (IAEA) conducts safety activities to support the assessment of occupational exposure due to intakes of radionuclides; a comprehensive set of safety documents will soon be completed. In recent years, extensive improvements in measurement techniques, phantoms and computational tools have been made. Thus, it is important for laboratories involved in internal dosimetry to undergo performance testing procedures to demonstrate the correctness of the methods applied and also to determine the consistency of their results with those obtained by other laboratories. Several intercomparisons were organised, and they revealed significant differences among laboratories in their approaches, methods and assumptions, and consequently in their results. This paper presents the current and future IAEA activities in support of assessment of occupational exposure due to intakes of radionuclides in the IAEA Member States, as well as the lessons learned from several intercomparison exercises in the last 5 years. (author)

  11. Results of the Marine Ice Sheet Model Intercomparison Project, MISMIP

    Directory of Open Access Journals (Sweden)

    F. Pattyn

    2012-05-01

    Full Text Available Predictions of marine ice-sheet behaviour require models that are able to robustly simulate grounding line migration. We present results of an intercomparison exercise for marine ice-sheet models. Verification is effected by comparison with approximate analytical solutions for flux across the grounding line using simplified geometrical configurations (no lateral variations, no effects of lateral buttressing. Unique steady state grounding line positions exist for ice sheets on a downward sloping bed, while hysteresis occurs across an overdeepened bed, and stable steady state grounding line positions only occur on the downward-sloping sections. Models based on the shallow ice approximation, which does not resolve extensional stresses, do not reproduce the approximate analytical results unless appropriate parameterizations for ice flux are imposed at the grounding line. For extensional-stress resolving "shelfy stream" models, differences between model results were mainly due to the choice of spatial discretization. Moving grid methods were found to be the most accurate at capturing grounding line evolution, since they track the grounding line explicitly. Adaptive mesh refinement can further improve accuracy, including fixed grid models that generally perform poorly at coarse resolution. Fixed grid models, with nested grid representations of the grounding line, are able to generate accurate steady state positions, but can be inaccurate over transients. Only one full-Stokes model was included in the intercomparison, and consequently the accuracy of shelfy stream models as approximations of full-Stokes models remains to be determined in detail, especially during transients.

  12. Revisiting the PLUMBER Experiments from a Process-Diagnostics Perspective

    Science.gov (United States)

    Nearing, G. S.; Ruddell, B. L.; Clark, M. P.; Nijssen, B.; Peters-Lidard, C. D.

    2017-12-01

    The PLUMBER benchmarking experiments [1] showed that some of the most sophisticated land models (CABLE, CH-TESSEL, COLA-SSiB, ISBA-SURFEX, JULES, Mosaic, Noah, ORCHIDEE) were outperformed - in simulations of half-hourly surface energy fluxes - by instantaneous, out-of-sample, and globally-stationary regressions with no state memory. One criticism of PLUMBER is that the benchmarking methodology was not derived formally, so that applying a similar methodology with different performance metrics can result in qualitatively different results. Another common criticism of model intercomparison projects in general is that they offer little insight into process-level deficiencies in the models, and therefore are of marginal value for helping to improve the models. We address both of these issues by proposing a formal benchmarking methodology that also yields a formal and quantitative method for process-level diagnostics. We apply this to the PLUMBER experiments to show that (1) the PLUMBER conclusions were generally correct - the models use only a fraction of the information available to them from met forcing data (sample of structural or epistemic uncertainty. We conclude by suggesting two ways to improve the experimental design of model intercomparison and/or model benchmarking studies like PLUMBER. First, PLUMBER did not report model parameter values, and it is necessary to know these values to separate parameter uncertainty from structural uncertainty. This is a first order requirement if we want to use intercomparison studies to provide feedback to model development. Second, technical documentation of land models is inadequate. Future model intercomparison projects should begin with a collaborative effort by model developers to document specific differences between model structures. This could be done in a reproducible way using a unified, process-flexible system like SUMMA [2]. [1] Best, M.J. et al. (2015) 'The plumbing of land surface models: benchmarking model

  13. Intercomparison and biokinetic model validation of radionuclide intake assessment. Report of a co-ordinated research project. 1996-1998

    International Nuclear Information System (INIS)

    1999-03-01

    This TECDOC presents the results of a Co-ordinated Research Project (CRP) on Intercomparison and Biokinetic Model Validation of Radionuclide Intake Assessment, including the conclusions of a Research Co-ordination Meeting held from 6 to 8 July 1998. The present CRP on Intercomparison and Biokinetic Model Validation of Radionuclide Intake Assessment is part of the activities of the IAEA's Occupational Protection programme. The objective of this programme is to promote an internationally harmonized approach for optimizing occupational radiation protection through: the development of guides, within the IAEA's activities for establishing standards for radiation protection, for restricting radiation exposures in the workplace and for applying current occupational radiation protection techniques; and the promotion of application of these guidelines

  14. Methods and advantages of intercomparisons of TLDs for environmental monitoring

    International Nuclear Information System (INIS)

    Ranogajec-Komor, M.; Klemic, G.

    1997-01-01

    One of the most difficult tasks facing the international community is the monitoring of environmental radiation for potential increases due to facility accidents or weapons activity. Monitoring networks have been established to provide a record of natural background radiation as well as measure any radiation releases from a facility. Thermoluminescent dosimeters (TLDs) are an important element of such networks and are the most widely used passive detector for environmental monitoring. In order to reach a high international standard in the application of TLDs in routine environmental monitoring, there is a need for a intercomparisons. (authors)

  15. Intercomparison of radionuclide measurements in marine sediment sample IAEA-368

    International Nuclear Information System (INIS)

    Ballestra, S.; Lopez, J.J.; Gastaud, J.; Parsi, P.; Vas, D.; Noshkin, V.

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-368, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 89 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for 60 Co, 155 Eu, 210 7Pb, 226 Ra, 238 U, 238 Pu and 239+240 Pu (Reference date: 1 January 1990). Information values for 40 K, 90 Sr, 137 Cs, 228 Th, 230 Th, 232 Th, 234 U, 235 U and 241 Am are also reported. (author)

  16. The inspirations with a radioactive intercomparison on a wine sample

    International Nuclear Information System (INIS)

    Su Qiong

    1993-12-01

    The methods used and results in a radioactive intercomparison on a wine sample are reported, which was organized by WHO-IRC in May, 1992. In order to analyse and compare the results obtained by all laboratories from WHO-IRC report (IRC NOTE No.41, 1993) are given. A re-measured new result about nuclide 40 K in the sample is also reported which coincides quite well with the result reported to IRC in a deviation of less than +-1%. And the problems concerning 'reference values' and standard sources etc. are also discussed

  17. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  18. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    Energy Technology Data Exchange (ETDEWEB)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.; Bezhenar, R.; Brown, J.; Cheng, J. -J.; Ćujić, M.; Dragović, S.; Duffa, C.; Fiévet, B.; Hosseini, A.; Jung, K. T.; Kamboj, S.; Keum, D. -K.; Kryshev, A.; LePoire, D.; Maderich, V.; Min, B. -I.; Periáñez, R.; Sazykina, T.; Suh, K. -S.; Yu, C.; Wang, C.; Heling, R.

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.

  19. Thermoluminescence analysis to detect irradiated fruit and vegetables - an intercomparison study. A report in English and German

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Wagner, U.; Helle, N.; Ammon, J.; Buchholtz, H.V.; Delincee, H.; Estendorfer, S.; Grabowski, H.U. von; Kruspe, W.; Mainczyk, K.; Muenz, H.; Schleich, C.; Vreden, N.; Wiezorek, C.; Boegl, K.W.

    1993-01-01

    This report describes in detail an intercomparison study to detect the irradiation of fruit and vegetables with a dose upwards of approx. 1 kGy. The 12 participating laboratories determined the thermoluminescence (TL) of mineral contaminations isolated from coded samples. Papayas, mangos, strawberries and mushrooms, which were either non-irradiated or irradiated with doses of between 1.4 and 1.6 kGy were chosen for examination as well as potatoes, which were either nonirradiated or treated with 200 Gy (for prevention of germination). The results of this intercomparison study were largely identical with those of the thermoluminescence intercomparison study on spice products. Therefore, it was applied to publish the method in the official collection of methods under article 35 of the German Foods Act (LMBG). In this method the integration of glow curves in a certain temperature range is recommended. The threshold value for the TL signal to distinguish irradiated and non-irradiated samples is fixed at 0.6. Under these conditions, all the non-irradiated samples in this intercomparison study and approx. 66% of the samples irradiated with doses of 1.4 to 1.6 kGy would have been correctly identified. As expected, the potato samples treated with a 200 Gy dose were not recognized as irradiated after normalization of the TL intensity using a re-irradiation dose of 1 kGy. Nevertheless, much higher TL intensities were recorded for the irradiated samples than for the non-irradiated samples in the first TL reading. By using different re-irradiation doses for the same mineral sample or by determining the re-irradiation dose that is required to obtain a TL signal value of approx. 1, however, it is possible to detect samples given a dose of below 1 kGy. The doses used to irradiate these samples can probably also be determined. The report deals briefly with this modified normalization procedure. (orig./VHE)

  20. The 1996 Radon Intercomparison Exercise at PSI

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.

    1997-05-01

    The 1996 Radon Intercomparison Exercise at PSI was organized by the PSI Reference Laboratory for Radon Gas Activity Concentration Measurements. A total of 14 laboratories, companies and institutions participated with radon gas detectors and measuring instruments. The detectors and instruments were exposed in the PSI radon chamber during seven days in a reference atmosphere with an average radon gas concentration of about 6000 Bqm -3 . Comparison of the results of electret ionization chambers, track etch detectors and measuring instruments with the PSI target value showed the criteria for traceability and reproducibility demanded by the Federal Office for Health for the acknowledgement of Swiss Radon Gas Measurement Laboratories to be fulfilled for all participants. Exposure of track etch detectors stored for more than one year demonstrated that this detector type can suffer sensitivity loss by a too long storage period. (author) figs., tabs., refs

  1. Czech results at criticality dosimetry intercomparison 2002.

    Science.gov (United States)

    Frantisek, Spurný; Jaroslav, Trousil

    2004-01-01

    Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV.

  2. An Intercomparison of ERS-Scat, AMSR-E Soil Moisture Observations with Model Simulations over France

    NARCIS (Netherlands)

    Rudiger, C.; Calvet, J.C.; Gruhier, C.; Holmes, T.R.H.; de Jeu, R.A.M.; Wagner, W.W.

    2009-01-01

    This paper presents a study undertaken in preparation of the work leading up to the assimilation of Soil Moisture and Ocean Salinity (SMOS) observations into the land surface model (LSM) Interaction Soil Biosphere Atmosphere (ISBA) at Météo-France. This study consists of an intercomparison

  3. Results of the regional intercomparison on internal dosimetry – 2013: Interpretation of monitoring data for effective dose assessment due to internal exposure

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the models applied and the results consistency. To that aim, the 1. Regional Intercomparison Exercise was organized in 2005 in the frame of the RLA 9/049. The results of this exercise led to the 2. Regional Intercomparison Exercise in 2013, which was organized in the frame of the RLA 9/066 and coordinated by Autoridad Regulatoria Nuclear (ARN) of Argentina. Four simulated cases covering intakes of “1”3”1I, “1”3”7Cs and Tritium were proposed. The exercise counted with the participation of 19 centres from 13 countries. This report shows a complete analysis of the participant’s results in this 2nd. exercise, useful to test their skills and acquired knowledge, particularly in applying the IDEAS guidelines. It is important to highlight the improvement in the general performance of the participants. (authors) [es

  4. Intercomparison of radiation protection instruments based on microdosimetric principles

    International Nuclear Information System (INIS)

    Dietze, G.; Guldbakke, S.; Kluge, H.; Schmitz, T.

    1986-11-01

    Dosemeters based on low-pressure tissue-equivalent proportional counters were developed for the application in radiation protection area monitoring by several groups in Europe. Five different prototypes have been intercompared in a 60 Co photon field, in monoenergetic neutron fields with various energies between 73 keV and 5 MeV and in three neutron fields at a 252 Cf source moderated by a D 2 O sphere. This report describes the radiation fields, the measuring devices and first results of the intercomparison. Additional measurements with a system used in microdosimetry and with a conventional dose equivalent rate meter for neutrons (Rem Counter) were also described. (orig.) [de

  5. International nuclear accident dosimetry intercomparison: results of Czech participation

    International Nuclear Information System (INIS)

    Spurny, F.; Votockova, I.

    1996-01-01

    An international intercomparison scheme for criticality accident dosimetry systems took place at the SILENE reactor, Valduc, France in June 1993. The dosemeters were exposed both on phantoms and in free air to radiation from the reactor, both shielded by lead and bare. The results obtained during this event by Czech participants are presented and compared with the average values obtained by the complete group of participants and with the reference values. The systems used consisted mostly of Si-diodes and thermoluminescent detectors, some supporting measurements were performed with solid state nuclear track detectors and using the albedo principle. The agreement between the data sets is very good. 7 tabs., 13 refs

  6. Austrian WBC intercomparison by means of a BOMAB phantom

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente; Edelmeier, R. [Bundesamt fuer Eich- und Vermessungswesen, Wien (Austria)

    1998-07-01

    The paper discusses the results obtained in the intercomparison between the Austrian Institute for Legal Metrology and the ENEA (National Agency for New Technology, Energy and the Environment) Institute for Radiation Protection, which gave a BOMAB phantom. Values related to potassium content and MBA (minimum detectable activity) for each identified nuclide are also discussed. [Italian] L'Istituto Austriaco di Metrologia Legale ha organizzato l'interconfronto usando un fantoccio gelificato di tipo BOMAB fornito dall'Istituto di Radioprotezione dell'ENEA nel periodo marzo-giugno 1996. Vengono riportati i risultati ottenuti relativi al contenuto di potassio e all'attivita' minima rilevabile (MDA) per ogni nuclide identificato.

  7. Report on the intercomparison run IAEA-308 radionuclides in seaweed mixture

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1989-12-01

    The results of an intercomparison exercise on a sample of mixed seaweeds from the Mediterranean Sea, IAEA-308, designed for the determination of artificial and natural radionuclide levels, are reported. The data from 67 laboratories representing 33 countries have been evaluated. The recommended median values, with confidence intervals, for the most frequently measured radionuclides 106 Ru, 110m Ag, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K, 210 Pb and 228 Th are given. Refs and tabs

  8. Results of the 1999. Intercomparison of Individual Monitoring Systems under the IAEA Model Project RLA/9/030

    International Nuclear Information System (INIS)

    Da Silva, Teogenes

    2000-01-01

    In this report the results of the second phase of the intercomparison program within the framework of the IAEA model project RLA/9/030 are presented. In this second phase the objective was to evaluate the performance in terms of the quantity personal dose equivalent, Hp (10) for x and gamma radiation in the energy range form 20 KeV to 1.25 MeV. The main purpose of phase II should be the verification of the quality and reliability of the personnel monitoring system of each participating country. The Centro de Desenvolvimento da Tecnologia Nuclear was the reference laboratory that verified the performance of the participant laboratories. The following countries were invited to participate in the 1999 intercomparison: Bolivia, Colombia, Costa Rica, Dominican Republic, el Salvador, Guatemala, Jamaica, Nicaragua, Panama and Paraguay

  9. A protocol for the intercomparison of marine fishery and ecosystem models: Fish-MIP v1.0

    Science.gov (United States)

    Tittensor, Derek P.; Eddy, Tyler D.; Lotze, Heike K.; Galbraith, Eric D.; Cheung, William; Barange, Manuel; Blanchard, Julia L.; Bopp, Laurent; Bryndum-Buchholz, Andrea; Büchner, Matthias; Bulman, Catherine; Carozza, David A.; Christensen, Villy; Coll, Marta; Dunne, John P.; Fernandes, Jose A.; Fulton, Elizabeth A.; Hobday, Alistair J.; Huber, Veronika; Jennings, Simon; Jones, Miranda; Lehodey, Patrick; Link, Jason S.; Mackinson, Steve; Maury, Olivier; Niiranen, Susa; Oliveros-Ramos, Ricardo; Roy, Tilla; Schewe, Jacob; Shin, Yunne-Jai; Silva, Tiago; Stock, Charles A.; Steenbeek, Jeroen; Underwood, Philip J.; Volkholz, Jan; Watson, James R.; Walker, Nicola D.

    2018-04-01

    Model intercomparison studies in the climate and Earth sciences communities have been crucial to building credibility and coherence for future projections. They have quantified variability among models, spurred model development, contrasted within- and among-model uncertainty, assessed model fits to historical data, and provided ensemble projections of future change under specified scenarios. Given the speed and magnitude of anthropogenic change in the marine environment and the consequent effects on food security, biodiversity, marine industries, and society, the time is ripe for similar comparisons among models of fisheries and marine ecosystems. Here, we describe the Fisheries and Marine Ecosystem Model Intercomparison Project protocol version 1.0 (Fish-MIP v1.0), part of the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP), which is a cross-sectoral network of climate impact modellers. Given the complexity of the marine ecosystem, this class of models has substantial heterogeneity of purpose, scope, theoretical underpinning, processes considered, parameterizations, resolution (grain size), and spatial extent. This heterogeneity reflects the lack of a unified understanding of the marine ecosystem and implies that the assemblage of all models is more likely to include a greater number of relevant processes than any single model. The current Fish-MIP protocol is designed to allow these heterogeneous models to be forced with common Earth System Model (ESM) Coupled Model Intercomparison Project Phase 5 (CMIP5) outputs under prescribed scenarios for historic (from the 1950s) and future (to 2100) time periods; it will be adapted to CMIP phase 6 (CMIP6) in future iterations. It also describes a standardized set of outputs for each participating Fish-MIP model to produce. This enables the broad characterization of differences between and uncertainties within models and projections when assessing climate and fisheries impacts on marine ecosystems and the

  10. A protocol for the intercomparison of marine fishery and ecosystem models: Fish-MIP v1.0

    Directory of Open Access Journals (Sweden)

    D. P. Tittensor

    2018-04-01

    Full Text Available Model intercomparison studies in the climate and Earth sciences communities have been crucial to building credibility and coherence for future projections. They have quantified variability among models, spurred model development, contrasted within- and among-model uncertainty, assessed model fits to historical data, and provided ensemble projections of future change under specified scenarios. Given the speed and magnitude of anthropogenic change in the marine environment and the consequent effects on food security, biodiversity, marine industries, and society, the time is ripe for similar comparisons among models of fisheries and marine ecosystems. Here, we describe the Fisheries and Marine Ecosystem Model Intercomparison Project protocol version 1.0 (Fish-MIP v1.0, part of the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP, which is a cross-sectoral network of climate impact modellers. Given the complexity of the marine ecosystem, this class of models has substantial heterogeneity of purpose, scope, theoretical underpinning, processes considered, parameterizations, resolution (grain size, and spatial extent. This heterogeneity reflects the lack of a unified understanding of the marine ecosystem and implies that the assemblage of all models is more likely to include a greater number of relevant processes than any single model. The current Fish-MIP protocol is designed to allow these heterogeneous models to be forced with common Earth System Model (ESM Coupled Model Intercomparison Project Phase 5 (CMIP5 outputs under prescribed scenarios for historic (from the 1950s and future (to 2100 time periods; it will be adapted to CMIP phase 6 (CMIP6 in future iterations. It also describes a standardized set of outputs for each participating Fish-MIP model to produce. This enables the broad characterization of differences between and uncertainties within models and projections when assessing climate and fisheries impacts on marine ecosystems

  11. AMBER and Ecolego Intercomparisons using Calculations from SR 97

    International Nuclear Information System (INIS)

    Maul, Philip; Robinson, Peter; Avila, Rodolfo; Broed, Robert; Pereira, Antonio

    2003-08-01

    The AMBER compartmental modelling software has been used by Quintessa in undertaking Performance Assessment (PA) calculations for SKI for the last four years. In particular, it was used in helping to identify key issues in the safety case for SFR 1. SSI and the Norwegian Radiation Protection Authority (NRPA) are supporting the development of Ecolego which is based on the Matlab/Simulink general purpose modelling software and provides a user-friendly Graphical User Interface which is particularly suitable for undertaking PA calculations. At SKI/SSI expert group meetings in September 2002, Quintessa presented some radionuclide transport calculations for a deep repository for spent fuel using AMBER. Comparisons were presented with calculations undertaken by SKB in their SR 97 study. It was agreed that it would be useful to undertake some intercomparison calculations using AMBER and Ecolego based on calculation cases considered in SR 97. The reasons for undertaking such intercomparisons include: 1. to give confidence in the use of AMBER and Ecolego for whole system PA calculations for a deep repository; and 2. to provide SKI and SSI with an understanding of some of the technical issues raised by seeking to repeat the SR 97 calculations with different models and software. This report documents the intercomparison calculations that have been undertaken. The main conclusions that have been drawn are: 1. Both modelling packages could successfully reproduce SKB's SR 97 calculations for the near field, geosphere and biosphere. 2. The results of the deterministic calculations for the near field and both deterministic and probabilistic calculations for the biosphere, where AMBER and Ecolego used compartment models, were typically in agreement to within one significant figure. The identical results for the calculated equilibrium inventories in Bay sediments illustrate that the calculations by AMBER and Ecolego are essentially the same when the compartment models are identical

  12. Intercomparison of γ-spectrometry analysis of radionuclides between China and Japan in 2012–2013

    International Nuclear Information System (INIS)

    Zhou, Qiang; Wang, Xiaoqiang; Tuo, Fei; Han, Yanqing; Ikeuchi, Yoshihiro; Yang, Jia; Xu, Cuihua; Zhang, Jing; Li, Wenhong; Zhang, Qing; Su, Xu

    2015-01-01

    An intercomparison of γ-spectrometry measurement and analysis was organized by the Japan Chemical Analysis Center (JCAC), the National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention (NIRP, China CDC), and the Radiation Monitoring Technical Center of Ministry of Environmental Protection, Chinese (RMTC). The main objective of this study was to assess the γ-spectrometry measurement and analysis technology. The JCAC completed the collection and preparation of soil and powdered rice samples. Three laboratories compared the measurement of seven radionuclides that included two samples of 214 Pb, 214 Bi, 208 Tl, 228 Ac, 40 K, 137 Cs, and 134 Cs with γ-spectrometry. During the studies conducted at the laboratory, the calculated value E n was found to be the total uncertainty data of the reported activity. Except 134 Cs in powdered rice sample, the calculated E n between each of the two laboratories was <1. The measurement results are acceptable except 134 Cs; therefore, measurement results in the three laboratories were consistent within a certain range except in the case of 134 Cs. Although there is a need to improve the accuracy of measurements and analysis of 134 Cs, an intercomparison was conducted of the tested levels on radionuclide analyzed in the three laboratories. - Highlights: • An intercomparison of γ-spectrometry measurement and analysis was organized. • Three laboratories compared the measurement of seven radionuclides. • Results for 40 K, 208 Tl, 214 Bi, 214 Pb, 228 Ac, and 137 Cs were well matched between two participants. • The results in the powder of the rice sample belonging to 134 Cs were the only ones assigned “not acceptable”.

  13. Intercomparison of model simulations of mixed-phase clouds observed during the ARM Mixed-Phase Arctic Cloud Experiment. Part II: Multi-layered cloud

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, H; McCoy, R B; Klein, S A; Xie, S; Luo, Y; Avramov, A; Chen, M; Cole, J; Falk, M; Foster, M; Genio, A D; Harrington, J; Hoose, C; Khairoutdinov, M; Larson, V; Liu, X; McFarquhar, G; Poellot, M; Shipway, B; Shupe, M; Sud, Y; Turner, D; Veron, D; Walker, G; Wang, Z; Wolf, A; Xu, K; Yang, F; Zhang, G

    2008-02-27

    Results are presented from an intercomparison of single-column and cloud-resolving model simulations of a deep, multi-layered, mixed-phase cloud system observed during the ARM Mixed-Phase Arctic Cloud Experiment. This cloud system was associated with strong surface turbulent sensible and latent heat fluxes as cold air flowed over the open Arctic Ocean, combined with a low pressure system that supplied moisture at mid-level. The simulations, performed by 13 single-column and 4 cloud-resolving models, generally overestimate the liquid water path and strongly underestimate the ice water path, although there is a large spread among the models. This finding is in contrast with results for the single-layer, low-level mixed-phase stratocumulus case in Part I of this study, as well as previous studies of shallow mixed-phase Arctic clouds, that showed an underprediction of liquid water path. The overestimate of liquid water path and underestimate of ice water path occur primarily when deeper mixed-phase clouds extending into the mid-troposphere were observed. These results suggest important differences in the ability of models to simulate Arctic mixed-phase clouds that are deep and multi-layered versus shallow and single-layered. In general, models with a more sophisticated, two-moment treatment of the cloud microphysics produce a somewhat smaller liquid water path that is closer to observations. The cloud-resolving models tend to produce a larger cloud fraction than the single-column models. The liquid water path and especially the cloud fraction have a large impact on the cloud radiative forcing at the surface, which is dominated by the longwave flux for this case.

  14. Report on the intercomparison run IAEA-307 radionuclides in sea plant

    International Nuclear Information System (INIS)

    Veglia, A.; Ballestra, S.; Vas, D.

    1989-10-01

    The results of an intercomparison exercise on a Mediterranean Sea plant sample, coded as IAEA-307, designed for the determination of artificial and natural radionuclide levels, are reported. This sample was collected along the shore from the vicinity of the Principality of Monaco in October 1986. The data from 66 laboratories representing 31 countries have been evaluated. The most frequently measured radionuclides: 106 Ru, 110m Ag, 134 Cs, 137 Cs, 238 Pu, 239+240 Pu, 241 Am, 40 K and 226 Ra. 10 refs, 38 tabs

  15. Intercomparison of techniques for the non-invasive measurement of bone mass

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques

  16. Intercomparison of radionuclide measurements in marine sediment sample IAEA-367

    International Nuclear Information System (INIS)

    Ballestra, S.; Lopez, J.J.; Gastaud, J.; Vas, D.; Noshkin, V.

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-367, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 81 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for 60 Co, 90 Sr, 137 Cs, 239+240 Pu (Reference date: 1 January 1990). Information values for 155 Eu, 238 Pu, 241 Am, and 241 Pu are reported. Information values for the following natural radionuclides 40 K, 226 Ra, 228 Th, 230 Th, 234 U, 235 U and 238 U are also reported. (author)

  17. Impact of Spatial Scales on the Intercomparison of Climate Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wei; Steptoe, Michael; Chang, Zheng; Link, Robert; Clarke, Leon; Maciejewski, Ross

    2017-01-01

    Scenario analysis has been widely applied in climate science to understand the impact of climate change on the future human environment, but intercomparison and similarity analysis of different climate scenarios based on multiple simulation runs remain challenging. Although spatial heterogeneity plays a key role in modeling climate and human systems, little research has been performed to understand the impact of spatial variations and scales on similarity analysis of climate scenarios. To address this issue, the authors developed a geovisual analytics framework that lets users perform similarity analysis of climate scenarios from the Global Change Assessment Model (GCAM) using a hierarchical clustering approach.

  18. BUBBLE - an urban boundary layer meteorology project

    DEFF Research Database (Denmark)

    Rotach, M.W.; Vogt, R.; Bernhofer, C.

    2005-01-01

    ground truth, as well as on urban turbulence and profiling (sodar, RASS, tethered balloon) were performed. Also tracer experiments with near-roof-level release and sampling were performed. In parallel to the experimental activities within BUBBLE, a meso-scale numerical atmospheric model, which contains...

  19. Intercomparison of preliminary MFR, SBUV, TOMS, and TOVS total ozone data

    International Nuclear Information System (INIS)

    Luther, F.M.

    1992-01-01

    The High Altitude Pollution Program of the Federal Aviation Administration is sponsoring a comparative study of total ozone data derived from various satellite instruments. The instruments included in the study are the Defense Meteorological Satellite Program's Multichannel Filter Radiometer (MFR), the NASA Solar Backscatter Ultraviolet Ozone Experiment (SBUV), the NASA Total Ozone Mapping Spectrometer (TOMS), and the NOAA Tiros Operational Vertical Sounder (TOVS). The two periods chosen for data intercomparison are January 1 - February 15, 1979 and June 1-30, 1979. These two data periods cover summer and winter regimes in both hemispheres. The January 1 - February 15, 1979 period includes a significant stratospheric warming event that began about January 15. Each of the satellite instruments has its own strengths and weaknesses. No instrument is universally better than or worse than any other in terms of accuracy, although they appear to have definite biases in certain geographical areas. The differences between the satellite systems is greatest at high latitudes where cloudiness and ozone variabilities are greatest. The Dobson data show a bias and differing degrees of ozone variability between nearby Dobson stations, which indicates there may be problems with using the Dobson data as a standard for comparison. The data used in this comparative study are preliminary in nature

  20. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose

    International Nuclear Information System (INIS)

    Andisco, D.; Blanco, S.; Bourel, V.; Schmidt, L.; Di Risio, C.

    2014-08-01

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  1. Last interglacial temperature evolution – a model inter-comparison

    Directory of Open Access Journals (Sweden)

    P. Bakker

    2013-03-01

    Full Text Available There is a growing number of proxy-based reconstructions detailing the climatic changes that occurred during the last interglacial period (LIG. This period is of special interest, because large parts of the globe were characterized by a warmer-than-present-day climate, making this period an interesting test bed for climate models in light of projected global warming. However, mainly because synchronizing the different palaeoclimatic records is difficult, there is no consensus on a global picture of LIG temperature changes. Here we present the first model inter-comparison of transient simulations covering the LIG period. By comparing the different simulations, we aim at investigating the common signal in the LIG temperature evolution, investigating the main driving forces behind it and at listing the climate feedbacks which cause the most apparent inter-model differences. The model inter-comparison shows a robust Northern Hemisphere July temperature evolution characterized by a maximum between 130–125 ka BP with temperatures 0.3 to 5.3 K above present day. A Southern Hemisphere July temperature maximum, −1.3 to 2.5 K at around 128 ka BP, is only found when changes in the greenhouse gas concentrations are included. The robustness of simulated January temperatures is large in the Southern Hemisphere and the mid-latitudes of the Northern Hemisphere. For these regions maximum January temperature anomalies of respectively −1 to 1.2 K and −0.8 to 2.1 K are simulated for the period after 121 ka BP. In both hemispheres these temperature maxima are in line with the maximum in local summer insolation. In a number of specific regions, a common temperature evolution is not found amongst the models. We show that this is related to feedbacks within the climate system which largely determine the simulated LIG temperature evolution in these regions. Firstly, in the Arctic region, changes in the summer sea-ice cover control the evolution of LIG winter

  2. Intercomparison for individual monitoring. Vol. 1

    International Nuclear Information System (INIS)

    1991-10-01

    Twenty-one laboratories from 19 countries participated in the Intercomparison. The exposures were conducted in May and June of 1988, and the dosimeters were returned to the participating laboratories for processing. The results were returned to the IAEA in late 1988. They were reviewed and compiled at the end of the year. The technical background for the CRP is described in the papers appearing in Parts 1 and 2 of this report. The results are summarized in Parts 3 and 4. An important aspect of the programme was comparison of the techniques used to evaluate the participants' dosimeters (Part 5). There are a number of technical and philosophical issues related to implementation of the ICRU operational quantities, particularly as they relate to needs of Agency Member States (Part 6). Various aspects of the dosimetry system affect the accuracy and precision of the overall results (Part 7). The report concludes with a Summary and Conclusions in Part 8, and a complete list of the participants is shown in Part 9. (orig./DG)

  3. Intercomparison of aerosol instruments: number concentration

    International Nuclear Information System (INIS)

    Knutson, E.O.; Sinclair, D.; Tu, K.W.; Hinchliffe, L.; Franklin, H.

    1982-05-01

    An intercomparison of aerosol instruments conducted February 23-27, 1981, at the Environmental Measurements Laboratory (EML) focused on five instruments: the Pollak and TSI condensation nucleus counters; the Active Scattering Aerosol Spectrometer (ASAS-X); and two aerosol electrometers. Test aerosols of sodium chloride and ammonium fluorescein generated by nebulization/electrostatic classification were used to obtain 195 lines of comparison data. Concentrations measured by the ASAS-X and the TSI aerosol electrometer averaged respectively 1.388 and 1.581 times that measured by the Pollak. These ratios were very stable during the week and there was little effect of particle size or material. Most other comparisons were equally stable. However, a review of past work at EML and elsewhere led to the disturbing conclusion that these ratios may change from year to year, or from season to season. A filter sample was taken from microscopy, concurrent with readings from the ASAS-X and the TSI condensation nucleus counters. In this sample, the two instruments differed by 20%. Within its 20% uncertainty, the filter result matched both the TSI and ASAS-X readings

  4. Intercomparison of NO3 radical detection instruments in the atmosphere simulation chamber SAPHIR

    Directory of Open Access Journals (Sweden)

    H.-P. Dorn

    2013-05-01

    Full Text Available The detection of atmospheric NO3 radicals is still challenging owing to its low mixing ratios (≈ 1 to 300 pptv in the troposphere. While long-path differential optical absorption spectroscopy (DOAS has been a well-established NO3 detection approach for over 25 yr, newly sensitive techniques have been developed in the past decade. This publication outlines the results of the first comprehensive intercomparison of seven instruments developed for the spectroscopic detection of tropospheric NO3. Four instruments were based on cavity ring-down spectroscopy (CRDS, two utilised open-path cavity-enhanced absorption spectroscopy (CEAS, and one applied "classical" long-path DOAS. The intercomparison campaign "NO3Comp" was held at the atmosphere simulation chamber SAPHIR in Jülich (Germany in June 2007. Twelve experiments were performed in the well-mixed chamber for variable concentrations of NO3, N2O5, NO2, hydrocarbons, and water vapour, in the absence and in the presence of inorganic or organic aerosol. The overall precision of the cavity instruments varied between 0.5 and 5 pptv for integration times of 1 s to 5 min; that of the DOAS instrument was 9 pptv for an acquisition time of 1 min. The NO3 data of all instruments correlated excellently with the NOAA-CRDS instrument, which was selected as the common reference because of its superb sensitivity, high time resolution, and most comprehensive data coverage. The median of the coefficient of determination (r2 over all experiments of the campaign (60 correlations is r2 = 0.981 (quartile 1 (Q1: 0.949; quartile 3 (Q3: 0.994; min/max: 0.540/0.999. The linear regression analysis of the campaign data set yielded very small intercepts (median: 1.1 pptv; Q1/Q3: −1.1/2.6 pptv; min/max: −14.1/28.0 pptv, and the slopes of the regression lines were close to unity (median: 1.01; Q1/Q3: 0.92/1.10; min/max: 0.72/1.36. The deviation of individual regression slopes from unity was always within the combined

  5. Assessment of the results of the 1998 Intercomparison of Individual Monitoring Systems under IAEA Model Project RLA/9/030

    International Nuclear Information System (INIS)

    Da Silva, Teogenes

    1999-01-01

    In this report the results of an intercomparison program within the framework of the IAEA model project RLA/9/030 are presented. This is the first phase of the study the main purpose was to establish a mechanism to identify and improve the current situation of each country as far as the performance of each individual monitoring system is concerned. This phase as was coordinated by Brazil through the Centro de Desenvolvimento da Tecnologia Nuclear that verified the performance of the participant laboratories. The following countries were invited to participate in the 1998 intercomparison: Bolivia, Costa Rica, Guatemala, Nicaragua, Panama, Jamaica and Paraguay. The performance of the laboratories was evaluated for dose assessment in terms of photon dose equivalent Hx

  6. Participation of the Laboratorio de Radiotoxicologia of IPEN, SP, Brazil, in laboratory inter-comparison programs

    International Nuclear Information System (INIS)

    Mesquita, Sueli Alexandra de; Carneiro, Janete Cristina G.

    2005-01-01

    The Radiotoxicology Laboratory (LRT) of IPEN/CNEN-SP has as mission to assess internal internal contamination from individuals through qualitative and quantitative analysis of radionuclides present in biological samples. The LRT is able to meet the demand for in vitro monitoring and radiological and nuclear emergencies, both in the case of occupational exposures, as individuals. With the purpose of increasing the reliability of the test results, and keeping it up to date on new analytical techniques, the LRT participates annually in two laboratory inter-comparison programs: a national, the PNI (Programa Nacional de Intercomparacao), promoted by IRD/CNEN and an international from PROCORAD (Association for the Promotion of Quality Controls in Radiotoxicological Bioassay). The present work shows the performance of the LRT by means of the results obtained in the exercises for the quantification of natural uranium and uranium isotopes, promoted by both the inter-comparison programs in the year of 2004. The analysis of the obtained results demonstrates the good performance achieved by LRT, and confirms the sustainability of its quality system, required in calibration and testing laboratories

  7. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Science.gov (United States)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  8. Status report on the Zagreb Radiocarbon Laboratory - AMS and LSC results of VIRI intercomparison samples

    Energy Technology Data Exchange (ETDEWEB)

    Sironic, Andreja [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Krajcar Bronic, Ines, E-mail: krajcar@irb.hr [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia); Horvatincic, Nada; Baresic, Jadranka; Obelic, Bogomil; Felja, Igor [Department of Experimental Physics, Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb (Croatia)

    2013-01-15

    A new line for preparation of the graphite samples for {sup 14}C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. {sup 14}C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 {+-} 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  9. Large-Scale Features of Pliocene Climate: Results from the Pliocene Model Intercomparison Project

    Science.gov (United States)

    Haywood, A. M.; Hill, D.J.; Dolan, A. M.; Otto-Bliesner, B. L.; Bragg, F.; Chan, W.-L.; Chandler, M. A.; Contoux, C.; Dowsett, H. J.; Jost, A.; hide

    2013-01-01

    Climate and environments of the mid-Pliocene warm period (3.264 to 3.025 Ma) have been extensively studied.Whilst numerical models have shed light on the nature of climate at the time, uncertainties in their predictions have not been systematically examined. The Pliocene Model Intercomparison Project quantifies uncertainties in model outputs through a coordinated multi-model and multi-mode data intercomparison. Whilst commonalities in model outputs for the Pliocene are clearly evident, we show substantial variation in the sensitivity of models to the implementation of Pliocene boundary conditions. Models appear able to reproduce many regional changes in temperature reconstructed from geological proxies. However, data model comparison highlights that models potentially underestimate polar amplification. To assert this conclusion with greater confidence, limitations in the time-averaged proxy data currently available must be addressed. Furthermore, sensitivity tests exploring the known unknowns in modelling Pliocene climate specifically relevant to the high latitudes are essential (e.g. palaeogeography, gateways, orbital forcing and trace gasses). Estimates of longer-term sensitivity to CO2 (also known as Earth System Sensitivity; ESS), support previous work suggesting that ESS is greater than Climate Sensitivity (CS), and suggest that the ratio of ESS to CS is between 1 and 2, with a "best" estimate of 1.5.

  10. Eleventh ORNL personnel dosimetry intercomparison study, May 22-23, 1985

    International Nuclear Information System (INIS)

    Swaja, R.E.; Oyan, R.; Sims, C.S.

    1986-07-01

    The Eleventh Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory (ORNL) during May 22-23, 1985. Dosimeter badges from 44 participating organizations were mounted on Lucite block phantoms and exposed to four mixed-radiation fields with neutron dose equivalents around 5 mSv and gamma dose equivalents between 0.1 and 0.7 mSv. Results of this study indicated that no participants had difficulty obtaining measurable indication of neutron exposure at the provided dose equivalent levels, and very few had difficulty obtaining indication of gamma exposure at dose equivalents as low as 0.10 mSv. Average neutron results for all dosimeter types were within 20% of reference values with no obvious spectrum dependence. Different dosimeter types (albedo, direct interaction TLD, film, recoil track, and combination albedo-track) with 10 or more reported measurements provided average results within 35% of reference values for all spectra. With regard to precision, about 80% of the reported neutron results had single standard deviations within 10% at the means which indicates that precision is not a problem relative to accuracy for most participants. Average gamma results were greater than reference values by factors of 1.07 to 1.52 for the four exposures with TLD systems being more accurate than film. About 80% of all neutron results and 67% of all gamma results met regulatory standards for measurement accuracy and approximately 70% of all neutron data satisfied national dosimetry accreditation criteria for accuracy plus precision. In general, neutron dosimeter performance observed in this intercomparison was much improved compared to that observed in the prior studies while gamma dosimeter performance was about the same

  11. Intercomparison measurements of activity of 99mTc and 131I in nuclear medicine services at Recife city, Pernambuco state, Brazil

    International Nuclear Information System (INIS)

    Barreto, F.C.P.; Santos, M.A.P dos; Oliveira, M.L.; Lima, F.F. de

    2007-01-01

    The aim of this work is to present the results of the first round of intercomparison measurements of activity of 99m Tc and 131 I. This round was carried out in Recife/PE. Six nuclear medicine services (NMS), public and private, participated in this intercomparison. Additionally to the activity measurement, some information about equipment (calibration and quality control program) and human resources was obtained. All NMS participants complied with the limit established by CNEN for the accuracy of measurement (+- 10%) for 99m Tc and 131 I. Measurements will be repeated for 99m Tc and 131 I, and additional rounds will be performed including different radionuclides. (author)

  12. Intercomparison of radionuclide measurements in marine sediment sample IAEA-368

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Lopez, J J; Gastaud, J; Parsi, P; Vas, D; Noshkin, V

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-368, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 89 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 60}Co, {sup 155}Eu, {sup 210}7Pb, {sup 226}Ra, {sup 238}U, {sup 238}Pu and{sup 239+240}Pu (Reference date: 1 January 1990). Information values for {sup 40}K, {sup 90}Sr, {sup 137}Cs, {sup 228}Th, {sup 230}Th, {sup 232}Th, {sup 234}U, {sup 235}U and {sup 241}Am are also reported. (author)

  13. Mixing heights over hilly terrain - a case study in northern austria

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, K. [Central Inst. for Meteorology and Geodynamics, ZAMG, Vienna (Austria)

    1997-10-01

    Simultaneous Sodar measurements (Remtech PA2) were conducted from 10 October 1996 to 24 January 1997 at two sites in northern Austria, near the village Allensteig on top of a hill (590 m.s.l.) and in the village Lenzing (460 m.s.l.) near the lake Attersee. The two sites are 145 km apart from each other and differ much according to the complexity of the surrounding terrain, land use and altitude. Mixing height and inversions height estimations from the Sodar measurements are compared with mixing heights derived from radiosonde potential temperature profiles at the next stations Linz and Vienna using the parcel method of Stull (1991) explained by M. Piringer (this volume). The information about the static stability at different Sodar heights, which is provided by the new Sodar software in terms of vertical temperature gradients, is discussed. (au)

  14. The 2008 intercomparison exercise for radon gas measurement instruments at PSI; Die Vergleichsmessung 2008 fuer Radongasmessgeraete am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2010-09-15

    Sixteen radon measurement services participated in the 2008 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) during August 28{sup th} to September 7{sup th}, 2008 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (etched-track, electronic and electret ionisation chambers) and instruments (ionization chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 627 Bq m{sup -3} leading to a radon gas exposure of 155 kBq h m{sup -3}. One measuring instrument participating for testing purposes stored values for part of the exposure interval (30.8. - 7.9.2008). The exposure during this partial interval was 117 kBq h m{sup -3} at an average radon gas concentration of 624 Bq m{sup -3}. The exposure of 155 kBq h m{sup -3} was the lowest used at the PSI intercomparisons down to the present day. Especially the LLT electret ionisation chambers used by some of the laboratories reached the lower end of their measurement range with this exposure. Unexpected deviations of instruments of the same model seem to show a dependence on the serial number and thus production date. (authors)

  15. Intercomparison of model simulations of mixed-phase clouds observed during the ARM Mixed-Phase Arctic Cloud Experiment. Part I: Single layer cloud

    Energy Technology Data Exchange (ETDEWEB)

    Klein, S A; McCoy, R B; Morrison, H; Ackerman, A; Avramov, A; deBoer, G; Chen, M; Cole, J; DelGenio, A; Golaz, J; Hashino, T; Harrington, J; Hoose, C; Khairoutdinov, M; Larson, V; Liu, X; Luo, Y; McFarquhar, G; Menon, S; Neggers, R; Park, S; Poellot, M; von Salzen, K; Schmidt, J; Sednev, I; Shipway, B; Shupe, M; Spangenberg, D; Sud, Y; Turner, D; Veron, D; Falk, M; Foster, M; Fridlind, A; Walker, G; Wang, Z; Wolf, A; Xie, S; Xu, K; Yang, F; Zhang, G

    2008-02-27

    Results are presented from an intercomparison of single-column and cloud-resolving model simulations of a cold-air outbreak mixed-phase stratocumulus cloud observed during the Atmospheric Radiation Measurement (ARM) program's Mixed-Phase Arctic Cloud Experiment. The observed cloud occurred in a well-mixed boundary layer with a cloud top temperature of -15 C. The observed liquid water path of around 160 g m{sup -2} was about two-thirds of the adiabatic value and much greater than the mass of ice crystal precipitation which when integrated from the surface to cloud top was around 15 g m{sup -2}. The simulations were performed by seventeen single-column models (SCMs) and nine cloud-resolving models (CRMs). While the simulated ice water path is generally consistent with the observed values, the median SCM and CRM liquid water path is a factor of three smaller than observed. Results from a sensitivity study in which models removed ice microphysics indicate that in many models the interaction between liquid and ice-phase microphysics is responsible for the large model underestimate of liquid water path. Despite this general underestimate, the simulated liquid and ice water paths of several models are consistent with the observed values. Furthermore, there is some evidence that models with more sophisticated microphysics simulate liquid and ice water paths that are in better agreement with the observed values, although considerable scatter is also present. Although no single factor guarantees a good simulation, these results emphasize the need for improvement in the model representation of mixed-phase microphysics. This case study, which has been well observed from both aircraft and ground-based remote sensors, could be a benchmark for model simulations of mixed-phase clouds.

  16. Precision intercomparison of beam current monitors at CEBAF

    International Nuclear Information System (INIS)

    Kazimi, R.; Dunham, B.; Krafft, G.A.; Legg, R.; Liang, C.; Sinclair, C.; Mamosser, J.

    1995-01-01

    The CEBAF accelerator delivers a CW electron beam at fundamental 1497 MHz, with average beam current up to 200 μA. Accurate, stable nonintercepting beam current monitors are required for: setup/control, monitoring of beam current and beam losses for machine protection and personnel safety, and providing beam current information to experimental users. Fundamental frequency stainless steel RF cavities have been chosen for these beam current monitors. This paper reports on precision intercomparison between two such RF cavities, an Unser monitor, and two Faraday cups, all located in the injector area. At the low beam energy in the injector, it is straightforward to verify the high efficiency of the Faraday cups, and the Unser monitor included a wire through it to permit an absolute calibration. The cavity intensity monitors have proven capable of stable, high precision monitoring of the beam current

  17. Intercomparison of Environmental Dosemeters Using Various TL Materials and Dosimetry Systems

    International Nuclear Information System (INIS)

    Crnic, B.; Gobec, S.; Zorko, B.; Knezevic, Z.; Majer, M.; Ranogajec-Komor, M.

    2013-01-01

    The aim of the present work was to compare the ambient dose equivalent (H*(10)) values determined at 20 sites around NPP Krško, using different thermoluminescence (TL) materials and various dosimetry systems. The H*(10) was measured by the CaF 2 :Mn (TLD-400) provided by the Jozef Stefan Institute (JSI) Ljubljana, Slovenia. These dosemeters were deployed in the environment in plastic bags and suspended inside the plastic bottles. On the other hand the Ruder Boskovic Institute (RBI), Zagreb, Croatia applied LiF:Mg,Cu,P (TLD-100H), CaF 2 :Mn, Al 2 O 3 :C TL detectors and radiophotoluminescence (RPL) glass dosemeters type SG1. They were placed at the same locations in as much as possible same conditions as JSI detectors. According to the protocol established for this intercomparison, the control and transport detectors (not deployed in the environment) were held in dark storage containers and used to determine the background radiation. The TL responses were corrected for individual sensitivity of the TL detectors which is an important factor after the calibration irradiations. The calibration irradiations were performed by 137Cs sources provided in Secondary Standard Dosimetry Laboratory facilities at the JSI and RBI. The results obtained by different TL materials and different dosimetry systems show interesting features especially concerning local environmental peculiarities. The H*(10) obtained by the dosemeters of various types deployed in the countryside fluctuate less than 10 %. The outcome should emphasize also in the manner that the results obtained and reported in the intercomparison are traceable to the primary standards.(author)

  18. National Centers for Environmental Prediction-Department of Energy (NCEP-DOE) Atmospheric Model Intercomparison Project (AMIP)-II Reanalysis (Reanalysis-2)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NCEP-DOE Atmospheric Model Intercomparison Project (AMIP-II) reanalysis is a follow-on project to the "50-year" (1948-present) NCEP-NCAR Reanalysis Project....

  19. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP

    Directory of Open Access Journals (Sweden)

    J. C. Orr

    2017-06-01

    Full Text Available The Ocean Model Intercomparison Project (OMIP focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6. OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations vs. when integrated within fully coupled Earth system models (CMIP6. Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948–2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6 and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen. Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1 will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation

  20. Biogeochemical Protocols and Diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    Science.gov (United States)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; hide

    2017-01-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF [subscript] 6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation

  1. Biogeochemical protocols and diagnostics for the CMIP6 Ocean Model Intercomparison Project (OMIP)

    Science.gov (United States)

    Orr, James C.; Najjar, Raymond G.; Aumont, Olivier; Bopp, Laurent; Bullister, John L.; Danabasoglu, Gokhan; Doney, Scott C.; Dunne, John P.; Dutay, Jean-Claude; Graven, Heather; Griffies, Stephen M.; John, Jasmin G.; Joos, Fortunat; Levin, Ingeborg; Lindsay, Keith; Matear, Richard J.; McKinley, Galen A.; Mouchet, Anne; Oschlies, Andreas; Romanou, Anastasia; Schlitzer, Reiner; Tagliabue, Alessandro; Tanhua, Toste; Yool, Andrew

    2017-06-01

    The Ocean Model Intercomparison Project (OMIP) focuses on the physics and biogeochemistry of the ocean component of Earth system models participating in the sixth phase of the Coupled Model Intercomparison Project (CMIP6). OMIP aims to provide standard protocols and diagnostics for ocean models, while offering a forum to promote their common assessment and improvement. It also offers to compare solutions of the same ocean models when forced with reanalysis data (OMIP simulations) vs. when integrated within fully coupled Earth system models (CMIP6). Here we detail simulation protocols and diagnostics for OMIP's biogeochemical and inert chemical tracers. These passive-tracer simulations will be coupled to ocean circulation models, initialized with observational data or output from a model spin-up, and forced by repeating the 1948-2009 surface fluxes of heat, fresh water, and momentum. These so-called OMIP-BGC simulations include three inert chemical tracers (CFC-11, CFC-12, SF6) and biogeochemical tracers (e.g., dissolved inorganic carbon, carbon isotopes, alkalinity, nutrients, and oxygen). Modelers will use their preferred prognostic BGC model but should follow common guidelines for gas exchange and carbonate chemistry. Simulations include both natural and total carbon tracers. The required forced simulation (omip1) will be initialized with gridded observational climatologies. An optional forced simulation (omip1-spunup) will be initialized instead with BGC fields from a long model spin-up, preferably for 2000 years or more, and forced by repeating the same 62-year meteorological forcing. That optional run will also include abiotic tracers of total dissolved inorganic carbon and radiocarbon, CTabio and 14CTabio, to assess deep-ocean ventilation and distinguish the role of physics vs. biology. These simulations will be forced by observed atmospheric histories of the three inert gases and CO2 as well as carbon isotope ratios of CO2. OMIP-BGC simulation protocols are

  2. The Agricultural Model Intercomparison and Improvement Project (AgMIP): Protocols and Pilot Studies

    Science.gov (United States)

    Rosenzweig, C.; Jones, J. W.; Hatfield, J. L.; Ruane, A. C.; Boote, K. J.; Thorburn, P.; Antle, J. M.; Nelson, G. C.; Porter, C.; Janssen, S.; hide

    2012-01-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a major international effort linking the climate, crop, and economic modeling communities with cutting-edge information technology to produce improved crop and economic models and the next generation of climate impact projections for the agricultural sector. The goals of AgMIP are to improve substantially the characterization of world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. Analyses of the agricultural impacts of climate variability and change require a transdisciplinary effort to consistently link state-of-the-art climate scenarios to crop and economic models. Crop model outputs are aggregated as inputs to regional and global economic models to determine regional vulnerabilities, changes in comparative advantage, price effects, and potential adaptation strategies in the agricultural sector. Climate, Crop Modeling, Economics, and Information Technology Team Protocols are presented to guide coordinated climate, crop modeling, economics, and information technology research activities around the world, along with AgMIP Cross-Cutting Themes that address uncertainty, aggregation and scaling, and the development of Representative Agricultural Pathways (RAPs) to enable testing of climate change adaptations in the context of other regional and global trends. The organization of research activities by geographic region and specific crops is described, along with project milestones. Pilot results demonstrate AgMIP's role in assessing climate impacts with explicit representation of uncertainties in climate scenarios and simulations using crop and economic models. An intercomparison of wheat model simulations near Obregón, Mexico reveals inter-model differences in yield sensitivity to [CO2] with model uncertainty holding approximately steady as concentrations rise, while uncertainty related to choice of crop model increases with

  3. Absolute measurement and international intercomparison of 0.1-0.8 MeV monoenergetic neutron fluence rate

    International Nuclear Information System (INIS)

    Ma Hongchang; Lu Hanlin; Rong Chaofan

    1988-01-01

    The methods for absolute measurement of 0.1-18MeV monoenergetic neutron fluence rate are described. Which include proton recoil telescope, semicoducetor telescope, hydrogen filled proportional counter and associated particale method. A long counter used as secondary recent international intercomparison of neutron fluence rate organized by BIPM, and the results were given

  4. International Intercomparison of Calorimeters. A Report of Measurements Made in the Reactor Melusine at C.E.N. Grenoble March 1970 by Eight Reactor Calorimetry Groups from Six Member States of the IAEA

    International Nuclear Information System (INIS)

    Boyd, A.W.

    1970-01-01

    The Working Group on Reactor Radiation Measurements has recommended an international intercomparison of calorimeters through its Subgroup 5 on calorimetric methods. Through the cooperation of the IAEA and the Centre d'Etudes Nucléaires de Grenoble of the Commissariat à l'Energie Atomique of France, the intercomparison was arranged. Representatives of eight dosimetry groups from six countries took part in this intercomparison which was carried out during the period 9-17 March 1970. This document will help workers in the field of absorbed dose measurements in reactors in choosing consistent and accurate procedures of experimentation and reporting data

  5. Is Comparability of 14C Dates an Issue?: A Status Report on the Fourth International Radiocarbon Intercomparison

    NARCIS (Netherlands)

    Bryant, C.; Carmi, I.; Cook, G.T.; Gulliksen, S.; Harkness, D.D.; Heinemeier, J.; McGee, E.; Naysmith, P.; Possnert, G.; Scott, E.M.; Plicht, J. van der; Strydonck, M. van

    2001-01-01

    For more than 15 years, the radiocarbon community has participated in a series of laboratory intercomparisons in response to the issue of comparability of measurements as perceived within the wider user communities (Scott et al. 1990; Rozanski et al. 1992; Guiliksen and Scott 1995; Scott et al.

  6. Intercomparison and intercalibration of passive/active radon and active radon progeny instruments and methods in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng W.

    1993-06-01

    An intercomparison and intercalibration exercise for radon and radon progeny measurements made with active and passive instruments was held at EML from October 22--30,1992. Twenty-five participants submitted 96 passive integrating devices, eight active devices for radon, and seven integrating devices for potential alpha energy concentration (PAEC). In addition, 40 grab samples for radon progeny analysis were taken by five groups that participated in person during the intercomparison. The results reported to EML indicate that the majority of the participants (70%) obtained mean results within 10% of the EML reference value. Although the instruments used in this exercise are based on different principles of collection and detection, they all appear reliable. However, in some instances there seemed to be some minor problems with quality control and calibration bias. Also, the large counting errors for the PAEC experienced by some of the participants can be minimized by using higher sampling air flow rates without sacrificing instrument portability

  7. The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor.

    Science.gov (United States)

    Gualdrini, G; Bedogni, R; Fantuzzi, E; Mariotti, F

    2004-01-01

    The present paper summarises the activity carried out at the ENEA Radiation Protection Institute for updating the methodologies employed for the evaluation of the neutron and photon dose to the exposed workers in case of a criticality accident, in the framework of the 'International Intercomparison of Criticality Accident Dosimetry Systems' (Silène reactor, IRSN-CEA-Valduc June 2002). The evaluation of the neutron spectra and the neutron dosimetric quantities relies on activation detectors and on unfolding algorithms. Thermoluminescent detectors are employed for the gamma dose measurement. The work is aimed at accurately characterising the measurement system and, at the same time, testing the algorithms. Useful spectral information were included, based on Monte Carlo simulations, to take into account the potential accident scenarios of practical interest. All along this exercise intercomparison a particular attention was devoted to the 'traceability' of all the experimental and computational parameters and therefore, aimed at an easy treatment by the user.

  8. Intercomparisons of nine sky brightness detectors.

    Science.gov (United States)

    den Outer, Peter; Lolkema, Dorien; Haaima, Marty; van der Hoff, Rene; Spoelstra, Henk; Schmidt, Wim

    2011-01-01

    Nine Sky Quality Meters (SQMs) have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across The Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between ±14%. Individual night time sums range from -16% to +20%. Intercalibration reduces this to 0.5%, and -7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 ± 0.003 mcd/m(2) on 12 April, and the largest value was 5.94 ± 0.03 mcd/m(2) on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.

  9. Radiative-convective equilibrium model intercomparison project

    Science.gov (United States)

    Wing, Allison A.; Reed, Kevin A.; Satoh, Masaki; Stevens, Bjorn; Bony, Sandrine; Ohno, Tomoki

    2018-03-01

    RCEMIP, an intercomparison of multiple types of models configured in radiative-convective equilibrium (RCE), is proposed. RCE is an idealization of the climate system in which there is a balance between radiative cooling of the atmosphere and heating by convection. The scientific objectives of RCEMIP are three-fold. First, clouds and climate sensitivity will be investigated in the RCE setting. This includes determining how cloud fraction changes with warming and the role of self-aggregation of convection in climate sensitivity. Second, RCEMIP will quantify the dependence of the degree of convective aggregation and tropical circulation regimes on temperature. Finally, by providing a common baseline, RCEMIP will allow the robustness of the RCE state across the spectrum of models to be assessed, which is essential for interpreting the results found regarding clouds, climate sensitivity, and aggregation, and more generally, determining which features of tropical climate a RCE framework is useful for. A novel aspect and major advantage of RCEMIP is the accessibility of the RCE framework to a variety of models, including cloud-resolving models, general circulation models, global cloud-resolving models, single-column models, and large-eddy simulation models.

  10. Intercomparisons of Nine Sky Brightness Detectors

    Directory of Open Access Journals (Sweden)

    Henk Spoelstra

    2011-10-01

    Full Text Available Nine Sky Quality Meters (SQMs have been intercompared during a night time measurement campaign held in the Netherlands in April 2011. Since then the nine SQMs have been distributed across the Netherlands and form the Dutch network for monitoring night sky brightness. The goal of the intercomparison was to infer mutual calibration factors and obtain insight into the variability of the SQMs under different meteorological situations. An ensemble average is built from the individual measurements and used as a reference to infer the mutual calibration factors. Data required additional synchronization prior to the calibration determination, because the effect of moving clouds combined with small misalignments emerges as time jitter in the measurements. Initial scatter of the individual instruments lies between ±14%. Individual night time sums range from −16% to +20%. Intercalibration reduces this to 0.5%, and −7% to +9%, respectively. During the campaign the smallest luminance measured was 0.657 ± 0.003 mcd/m2 on 12 April, and the largest value was 5.94 ± 0.03 mcd/m2 on 2 April. During both occurrences interfering circumstances like snow cover or moonlight were absent.

  11. Experimental and theoretical study of the atmospheric boundary layer over the paris area; Etude experimentale et theorique de la couche limite atmospherique en agglomeration parisienne

    Energy Technology Data Exchange (ETDEWEB)

    Menut, L

    1997-12-15

    This thesis studied the urban boundary layer dynamic behaviour over the Paris area by comparing urban (Paris) and suburban (Palaiseau) dynamic data such as lidars, sodars, sonic anemometers. All the data were obtained during the ECLAP experiment, specifically performed to characterize the differences between a city and its near environment. (author)

  12. Status report on the Zagreb Radiocarbon Laboratory – AMS and LSC results of VIRI intercomparison samples

    International Nuclear Information System (INIS)

    Sironić, Andreja; Krajcar Bronić, Ines; Horvatinčić, Nada; Barešić, Jadranka; Obelić, Bogomil; Felja, Igor

    2013-01-01

    A new line for preparation of the graphite samples for 14 C dating by Accelerator Mass Spectrometry (AMS) in the Zagreb Radiocarbon Laboratory has been validated by preparing graphite from various materials distributed within the Fifth International Radiocarbon Intercomparison (VIRI) study. 14 C activity of prepared graphite was measured at the SUERC AMS facility. The results are statistically evaluated by means of the z-score and u-score values. The mean z-score value of 28 prepared VIRI samples is (0.06 ± 0.23) showing excellent agreement with the consensus VIRI values. Only one sample resulted in the u-score value above the limit of acceptability (defined for the confidence interval of 99%) and this was probably caused by a random contamination of the graphitization rig. After the rig had been moved to the new adapted and isolated room, all u-score values laid within the acceptable limits. Our LSC results of VIRI intercomparison samples are also presented and they are all accepted according to the u-score values.

  13. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  14. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  15. Intercomparison of radionuclide measurements in marine sediment sample IAEA-135

    International Nuclear Information System (INIS)

    Ballestra, S.; Gastaud, J.; Lopez, J.J.; Parsi, P.; Vas, D.

    1993-08-01

    The results of an intercomparison exercise on a marine sediment from Irish Sea, IAEA-135, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 151 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, for 40 K, 60 Co, 134 Cs, 137 Cs, 154 Eu, 155 Eu, 226 Ra, 228 Ra, 232 Th, 238 Pu, 239+240 Pu (Reference date: 1 January 1992). Information values for 57 Co, 90 Sr, 106 Ru, 125 Sb, 210 Pb, 210 Po, 228 Th, 230 Th, 234 U, 235 U, 238 U and 241 Am are also reported. All values are expressed in Bq kg -1 dry weight. (author)

  16. Intercomparison of radionuclide measurements on marine sediment sample IAEA-300

    International Nuclear Information System (INIS)

    Ballestra, S.; Gastaud, J.; Lopez, J.J.; Parsi, P.; Vas, D.

    1994-09-01

    The results of an intercomparison exercise on a sediment from Baltic Sea, IAEA-300, designed for the determination of artificial and natural radionuclides' levels, are reported. The data from 159 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, 40 K, 60 Co, 125 Sb, 134 Cs, 137 Cs, 155 Eu, 210 Pb, 210 Po, 228 Ra, 234 U, 238 U, 239+240 Pu and 241 Am. Information values for 54 Mn, 90 Sr, 226 Ra, 228 Th, 230 Th, 232 Th, 235 U and 238 Pu are also reported. All values are given on the reference date of 1 January 1993 and expressed in Bq kg -1 dry weight. (author)

  17. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  18. Intercomparison of radionuclide measurements in marine sediment sample IAEA-367

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Lopez, J J; Gastaud, J; Vas, D; Noshkin, V

    1991-08-01

    The results of an intercomparison exercise on a Pacific Ocean sediment sample, IAEA-367, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 81 laboratories representing 37 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 60}Co, {sup 90}Sr, {sup 137}Cs, {sup 239+240}Pu (Reference date: 1 January 1990). Information values for {sup 155}Eu, {sup 238}Pu, {sup 241}Am, and {sup 241}Pu are reported. Information values for the following natural radionuclides {sup 40}K, {sup 226}Ra, {sup 228}Th, {sup 230}Th, {sup 234}U, {sup 235}U and {sup 238}U are also reported. (author)

  19. Intercomparison test on hearing protectors (EU, VG4)

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1997-01-01

    Real Ear Attenuation at Threshold (REAT) was measured on 16 human test subjects in accordance with EN 24869-1. Insertion loss for the individual cups was determined in accordance with EN 352-1, paragraph 7.11-7.11.3.3. Both the REAT and the insertion loss measurements were performed in an approxi......Real Ear Attenuation at Threshold (REAT) was measured on 16 human test subjects in accordance with EN 24869-1. Insertion loss for the individual cups was determined in accordance with EN 352-1, paragraph 7.11-7.11.3.3. Both the REAT and the insertion loss measurements were performed...... in an approximated diffuse field. The field was established in a semi reverberant room with uncorrelated one-third octave bands of noise from two loudspeakers. The measurements are part of a European intercomparison project 'Sound attenuation in accordance with EN-24869-1'....

  20. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  1. Adaptation of a free radical dosimeter to the intercomparison of fast neutron beams. Part of a coordinated programme on the development of a transfer instrument for neutron dosimetry intercomparison

    International Nuclear Information System (INIS)

    Bermann, F.

    1978-07-01

    A compressed mixture of alanine and paraffin is a compact and uniform dosemeter with good reproducibility and practical use of it can be made in the range from 10 2 to 10 7 rad. These dosemeters are virtually tissue-equivalent as regards to the absorption of ionizing radiation, especially in the case of fast neutrons. The detection efficiency decreases in the case of particles with high LET. As far as intercomparisons are concerned, this dosemeter shows good relative accuracy of the data and affords an opportunity of successive readings after intervals of time

  2. Reference dosimetry and small-field dosimetry in external beam radiotherapy: Results from a Danish intercomparison study

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Behrens, Claus F.; Sibolt, Patrik

    methods was performed by DTU Nutech at six Danish clinics. The first part of the intercompa-rison regarded the consistency of reference dosimetry. Absorbed dose to water under reference conditions was measured using a Farmer ionization chamber, and was found to agree within 1 % with the daily dose checks......-specific correction factors for non-reference fields....

  3. Results of the regional intercomparison exercise for the determination of operational quantity Hp(d) in Latin America

    International Nuclear Information System (INIS)

    Saravi, M.; Zaretzky, A.; Lindner, C.; Diaz, J.; Walwyn, G.; Souza, D.; Amorin, R.; Gregory, B.; Papadopulos, S.; Meghzifene, A.; Ferruz Cruz, P.; Cruz Suarez, R.

    2005-01-01

    Full text: Several intercomparison exercises were organized by the International Atomic Energy Agency (IAEA) on the determination of operational quantities at the regional or interregional basis. These exercises revealed significant differences in the approach, methods and assumptions, and consequently in the measurement results obtained by participating laboratories. In the Latin America region, an intercomparison for determination of operational quantity Hp(10), organized within the frame of a technical cooperation regional project, was completed mid-2004, as a follow-up to previous exercises carried out during the 1990s. Eighteen laboratories from 19 member states participated in the first phase; the second phase grouped 15 laboratories from 16 member states. Dosimeter irradiations (5 different radiation qualities for photon simulating workplace fields) were done by 4 Secondary Standards Dosimetry Laboratories (SSDL). The preparations for the exercise involved an audit by the IAEA SSDL, where reference irradiations were provided to all participants for verification of their system. During the first phase (2002/03), only 9 out of 18 laboratories met the performance requirements for such monitoring services. Necessary corrective actions and procedure verification were implemented, and staff involved in these evaluations were subsequently trained. During the second phase (2004), 11 out of 15 laboratories fulfilled the performance criteria. The 4 laboratories still having difficulties in assessing occupational exposure participated in a results meeting, during which problem areas were identified. An ongoing technical cooperation mission is expected to assist these laboratories accordingly. There has been a definite improvement in the second phase and most laboratories demonstrated a good performance in the quantity tested. The technical results clearly show that the laboratories' capability in assessing occupational exposure from external sources of radiation is

  4. Intercomparison of calibration procedures of high dose rate 192 Ir sources in Brazil and a proposal of a new methodology

    International Nuclear Information System (INIS)

    Marechal, M.H.; Almeida, C.E. de

    1998-01-01

    The objective of this paper is to report the results of an intercomparison of the calibration procedures for 192 Ir sources presently in use in Brazil and to proposal a calibration procedure to derive the N k for a Farmer type ionization chamber for 192 Ir energy by interpolating from a 60 Co gamma-rays and 250 kV x-rays calibration factors. the intercomparison results were all within ± 3.0 % except one case where 4.6 % was observed and latter identified as a problem with N-k value for X-rays. The method proposed by the present work make possible the improvement of the metrological coherence among the calibration laboratories and their users once the N k values could then provided by any of the members of SSDL network. (Author)

  5. Argentine Republic intercomparison programme for personal dosimeters

    International Nuclear Information System (INIS)

    Gregori, Beatriz N.; Papadopulos, Susana B.; Kunst, Juan J.; Cruzate, Juan A.; Saravi, Margarita C.

    2004-01-01

    In 1997 an Intercomparison Program for individual monitoring started in order to test (on a voluntary basis) the performance in absorbed dose and personal dose equivalent determinations. The aim of the program was also to gain some insight into the general aspects related to the type of the personnel dosimeter used, the calibration procedures, the phantom spectral dependence and the management of radiological quantities. The Regional Reference Center for Dosimetry (CCR), of the Argentine National Atomic Energy Commission and the Physical Dosimetry Laboratory of the Argentine National Regulatory Authority, performed the irradiations. Those were done free air and on ICRU phantom, using X-ray, quality ISO: W60, W80, W110 and W200; and 137 Cs and 60 Co gamma rays, normal and angular (0, 30, 60 degrees) incidence. In the framework of the Program, an upgraded workshop took place and the national standard, IRAM 17146, was elaborated as well. In this work, the laboratories performance and its temporal evolution is shown from 1997 up to 2002. The suggestions to improve their performance are also included. (author)

  6. Report on the intercomparison run IAEA-152 radionuclides in milk powder

    International Nuclear Information System (INIS)

    Cooper, E.L.; LaBrecque, J.J.; Dekner, R.; Reichel, F.; Schelenz, R.

    1988-09-01

    The results of the intercomparison on milk powder (IAEA-152) for the determination of elevated levels of radioactivity are reported. The data from thirty-nine laboratories from eighteen different countries have been considered and include the determination of the following radionuclides: 134 Cs, 137 Cs, 40 K, 90 Sr. According to a statistical evaluation sufficient data for recommended mean values and confidence intervals have been received for: 134 Cs: 764 Bq/kg (722-802); 137 Cs: 2129 Bq/kg (2053-2209); 40 K: 539 Bq/kg (510-574); 90 Sr: 7.7 Bq/kg (7.0-8.3). Reference date: 31 August 1987. 3 refs, figs and tabs

  7. Report on the intercomparison run IAEA-154 radionuclides in whey powder

    International Nuclear Information System (INIS)

    Cooper, E.L.; LaBrecque, J.J.; Dekner, R.; Reichel, F.; Schelenz, R.

    1988-09-01

    The results of the intercomparison on whey powder (IAEA-154) for the determination of elevated levels of radioactivity are reported. The data for thirty-one laboratories from sixteen different countries have been considered and include the determination of the following radionuclides: 134 Cs, 137 Cs, 40 K, 90 Sr. According to a statistical evaluation sufficient data for recommended mean values and confidence intervals have been received for: 134 Cs: 1355 Bq/kg (1295-1417); 137 Cs: 3749 Bq/kg (3613-3887); 40 K: 1575 Bq/kg (1511-1644); 90 Sr: 6.9 Bq/kg (6.0-8.0). Reference date: 31 August 1987. 3 refs, figs and tabs

  8. Participation of the Nuclear Regulatory Authority in the uranium urinalysis intercomparisons

    International Nuclear Information System (INIS)

    Bonino, Nestor O.; Palacios, Miguel A.; Serdeiro, Nelida H.

    1999-01-01

    In the present work the results of the participation of Nuclear Regulatory Authority (NRA) Argentina, in the Uranium Urinalysis Intercomparison Program administered by the National Calibration Reference Centre for Bioassay, Radiation Protection Bureau, Health Canada, are detailed. This work is referred to the three participations of NRA in 1995, 1996, and 1997. The number of laboratories that have participated was 14, 12 and 12. A statistical analysis is presented. The performance criteria used for assessing the acceptability of results are those given in the American National Standard Institute (ANSI) 1989, N13.30. In addition, the applied radiochemical technique and the methodology are described. (author)

  9. Results of the Argentinian intercomparison on internal dosimetry – 2014. Interpretation of monitoring data for effective dose assessment due to internal exposure

    International Nuclear Information System (INIS)

    Rojo, A.M.; Puerta, N.; Gossio, S.; Gómez Parada, I.

    2015-01-01

    Internal dosimetry intercomparisons are essential for the verification of the models applied and the results consistency. To that aim, in 2014 the National Intercomparison Exercise was organized and coordinated by the Internal Dosimetry Laboratory of the Nuclear Regulatory Authority (ARN) of Argentina. Four simulated cases covering intakes of “1”3”1I, “1”3”7Cs and tritium were proposed. The exercise counted with the participation of four internal dosimetry services from the nuclear power plants (NA-SA CNA and NA-SA CNE) and the CNEA Atomic Centres: Bariloche (CAB) and Ezeiza (CAE). This report shows a complete analysis of the participant’s results in this exercise. (authors) [es

  10. Solutions to HYDROCOIN [Hydrologic Code Intercomparison] Level 1 problems using STOKES and PARTICLE (Cases 1,2,4,7)

    International Nuclear Information System (INIS)

    Gureghian, A.B.; Andrews, A.; Steidl, S.B.; Brandstetter, A.

    1987-10-01

    HYDROCOIN (Hydrologic Code Intercomparison) Level 1 benchmark problems are solved using the finite element ground-water flow code STOKES and the pathline generating code PARTICLE developed for the Office of Crystalline Repository Development (OCRD). The objective of the Level 1 benchmark problems is to verify the numerical accuracy of ground-water flow codes by intercomparison of their results with analytical solutions and other numerical computer codes. Seven test cases were proposed for Level 1 to the Swedish Nuclear Power Inspectorate, the managing participant of HYDROCOIN. Cases 1, 2, 4, and 7 were selected by OCRD because of their appropriateness to the nature of crystalline repository hydrologic performance. The background relevance, conceptual model, and assumptions of each case are presented. The governing equations, boundary conditions, input parameters, and the solution schemes applied to each case are discussed. The results are shown in graphic and tabular form with concluding remarks. The results demonstrate the two-dimensional verification of STOKES and PARTICLE. 5 refs., 61 figs., 30 tabs

  11. An intercomparison of methods for the determination of ochratoxin A in pig kidney

    DEFF Research Database (Denmark)

    Entwisle, A. C.; Jørgensen, Kevin; Williams, A. C.

    1997-01-01

    , Measurements and Testing Programme, which is the successor of the Community Bureau of Reference (BCR). The materials were prepared from blank and naturally-contaminated pig kidneys and were freeze-dried. Details are given on the freeze-drying and packaging procedure, and the checks to ensure homogeneity...... and stability of the freeze-dried materials. The intercomparison study involved 20 European laboratories, which analysed the naturally-contaminated (freeze-dried) sample (ochratoxin A content approximately 10 mu g/kg based on fresh weight) and the 'blank' sample (ochratoxin A content...

  12. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated [it

  13. Analytical quality control service programme, intercomparison runs, certified reference materials, reference materials 1987-88

    International Nuclear Information System (INIS)

    1986-12-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the IAEA, is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. The tables give details of the intercomparison samples and reference materials distributed by the IAEA in the period 1987 to 1988. 2 tabs

  14. Report on the intercomparison run IAEA-352 radionuclides in tuna fish flesh

    International Nuclear Information System (INIS)

    Ballestra, S.; Vas, D.; Lopez, J.J.; Noshkin, V.

    1990-08-01

    The results of an intercomparison exercise on a sample of tuna fish flesh from the Mediterranean Sea, IAEA-352, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 63 laboratories from 31 countries have been evaluated. The following are the recommended values, with confidence intervals, for the most frequently measured radionuclides (Reference data: 1 January 1989): 137 Cs 2.7 Bq kg -1 , 90 Sr 0.2 Bq Kg -1 , 40 K 391 Bq Kg -1 , 210 Pb 0.6 Bq Kg -1 , 210 Po 2.2 Bq Kg -1 . Tabs

  15. Intercomparison of radionuclide measurements in marine fish flesh sample MA-B-3

    International Nuclear Information System (INIS)

    1987-08-01

    This final report presents results of the laboratory intercomparison of the activity concentration determination of 40 K, 90 Sr, 137 Cs, 210 Pb, 210 Po, 226 Ra, 228 Th, 230 Th, 232 Th, 238 U, 239 Pu, 240 Pu and 241 Am in the sample of garpike fish organized by the IAEA's Analytical Quality Control Service. The forty-three laboratories from twenty-three countries have reported results established by different analytical techniques. This sample is intended as a reference material for the measurement of 40 K and 137 Cs in marine biological samples and other similar matrices. 4 refs, 9 tabs

  16. The IAEA intercomparison for individual monitoring

    International Nuclear Information System (INIS)

    Griffith, R.V.; Boehm, J.; Herrman, D.; Strachotinsky, C.; Thompson, I.M.G.

    1990-01-01

    In 1985 the International Commission on Radiation Units and Measurements introduced a new set of operational quantities for radiation protection purposes through Report 39. The International Atomic Energy Agency has been concerned with the impact of possible adoption of these quantities by its 113 Member States. Thus the Agency implemented a Coordinated Research Programme on Intercomparison for Individual Monitoring in 1987. The first phase completed with a Research Coordination meeting of the participants in April, 1989. Photon exposures were provided at 11 energies over a range from 18 keV to 1.25 MeV at three standards laboratories in Austria, the GDR and the UK. Technical coordination was provided by the PTB, Braunschweig. Twenty one laboratories from 19 countries participated with film, TLD of various types, and combination dosemeters. Irradiations were performed on the IAEA 30 cm cubic, water-filled phantom that is in use throughout its network of 61 Secondary Standard Dosimetry Laboratories. Conversion coefficients for the IAEA phantom were calculated by the PTB and confirmed through measurements at ASMW in the GDR. Preliminary results indicated that the type of dosemeter (film or TLD) had little effect on the quality of results. The most important factor appears to be the specific techniques used for data interpretation. (author)

  17. Intercomparison Contracted Partner Institutes for Nuclear Emergency 2007; Ringonderzoek waakvlaminstituten kernongevallenbestrijding 2007

    Energy Technology Data Exchange (ETDEWEB)

    Overwater-van Buuren, R.M.W.; Glastra, P.; Tukker, K.

    2009-07-01

    The quality of the so-called Contracted Partner Institutes (CPI's) is amply complying with the objectives. Nonetheless, some desirable improvements remain, especially issues concerning the calibration of the measuring equipment. These issues emerged during an investigation performed by RIVM, in which the quality of the analysis of water and air samples was tested. In the Netherlands there are eight CPI's, evenly spread across the country, who can inform the government about radioactivity in air and water. The CPIs are part of the Dutch National Plan for Nuclear Emergency Planning and Response, which has been drawn up after the nuclear disaster in Chernobyl. RIVM is coordinating the activities of the CPI's. The Contracted Partner Institutes are tested on a two-yearly base by way of intercomparisons. In these intercomparisons, testing is done on both the timely reporting of the results and on the agreement with the reference value within pre-defined boundaries. Most CPI's were able to deliver the air results within two hours, and the water results within 24 hours. The results of the air samples for one institute were outside the pre-defined boundaries. Four samples were prepared for the intercomparison: an aerosol filter, a charcoal filter, a charcoal cartridge and a water sample. All four contained radionuclides characteristic for nuclear accidents. [Dutch] De kwaliteit van de zogeheten Waakvlaminstituten (WVI's) voldoet in 2007 ruimschoots aan de doelstellingen. Wel zijn enkele verbeteringen wenselijk, vooral op het gebied van kalibratie van de meetopstellingen. Dit blijkt uit onderzoek van het RIVM waarin de kwaliteit is getest van de analyse van water- en luchtmonsters. In Nederland bestaan er verspreid over het land acht WVI's die bij een kernongeval de overheid informeren over radioactiviteit in lucht en water. De WVI's zijn een onderdeel van het Nationaal Plan Kernongevallenbestrijding (NPK), dat is opgesteld enkele jaren na

  18. Quality control in environmental radioactivity measurements: experience of the Central Service for Protection against Ionizing Radiation, acting as International Reference Center Of the World Health Organization

    Energy Technology Data Exchange (ETDEWEB)

    Remy, M L; Gahinet, M E; Moroni, J P; De Zertucha, J; Pellerin, P [Service Central de Protection contre les Rayonnements Ionisants, 78 - Le Vesinet (France)

    1978-01-01

    The purpose of this paper is to make known the experiences in the Central Service for Protection against Ionizing Radiation (SCPRI) in two fields: (i)in relation to the survey of, and research on, environmental radiation in France for 15 years, and (ii) as the International Reference Center (IRC), a responsibility which has been assigned to it by the World Health Organisation (WHO) for more than 7 years. The SCPRI has no permanent activity in pure metrology but the control which it exerts on a national scale (more than 30,000 environmental samples analyzed each year) and the periodic intercomparisons which it organizes with a large number of foreign Public Health Laboratories have led to the development of a strict quality control program for the techniques of preparation and verification of standard sources and reference samples which are essential in the use of counters, the application and development of spectrometric and radiochemical analytical methods and in the distribution of samples for intercomparison purposes. A description is given of practical experience of quality control in the preparation of standards and in international inter-comparisons organized under the sponsorship of the World Health Organization.

  19. An international intercomparison of national network systems used to provide early warning of a nuclear accident having transboundary implications

    DEFF Research Database (Denmark)

    Thompson, I.M.G.; Andersen, C.E.; Bøtter-Jensen, L.

    2000-01-01

    be harmonised so that it can be accurately interpreted by other countries and by international organisations. To assist with such harmonisation an intercomparison was held during May/June 1999 at the Riso Natural Environmental Radiation Measurement Station in Denmark and at the PTB underground laboratory...

  20. Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

    Czech Academy of Sciences Publication Activity Database

    Farah, J.; Mares, V.; Romero-Exposito, M.; Trinkl, S.; Domingo, C.; Dufek, V.; Klodowska, M.; Kubančák, Ján; Knezevic, Z.; Ploc, Ondřej

    2015-01-01

    Roč. 42, č. 5 (2015), s. 2572-2584 ISSN 0094-2405 Institutional support: RVO:61389005 Keywords : scanning proton therapy * measurement of stray neutrons * spectrometry * ambient dose eyuivalent * intercomparison Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 2.496, year: 2015

  1. Intercomparison of analysis methods for the assay of traces of platinum and palladium

    International Nuclear Information System (INIS)

    Pauwels, J.

    1978-01-01

    This report describes experimental procedures and results of an intercomparison organized by the Commission of the European Communities, in which more than 20 laboratories participated using up to 12 different methods of analysis. The analysed samples were synthetic alloys containing 1 to 100 μg/g Pt or Pd, which were quantitatively prepared using high-frequency levitation melting. The accuracy of the preparation method, as well as its reproducibility were demonstrated. Neutron, photon, and proton activation analysis as well as flameless atomic absorption spectroscopy come out as the most suitable analytical methods

  2. Intercomparison of personal radiation monitoring services in the Asia/Pacific region- our participation

    International Nuclear Information System (INIS)

    Dhond, R.V.; Worlikar, R.M.; Saralamma Nair, D.; Pathak, A.S.; Sankaran, M.P.; Shenoy, K.S.; Patel, P.H.

    1994-01-01

    Radiation Protection Services Division participated in the intercomparison of personal monitoring services in Asia/Pacific region during 1991-92 organised by Australian Radiation Laboratory (ARL). The exposed films returned by ARL were processed in our laboratory. The nature and energies of the incident radiations were identified and doses evaluated in terms of new operational quantities. The doses evaluated were within ± 20% except in two cases where energy determination did not match with the ARL values. The results are presented in the paper. (author). 1 ref., 3 tabs

  3. Interpretation of complexometric titration data: An intercomparison of methods for estimating models of trace metal complexation by natural organic ligands

    NARCIS (Netherlands)

    Pižeta, I.; Sander, S.G.; Hudson, R.J.M.; Omanovic, D.; Baars, O.; Barbeau, K.A.; Buck, K.N.; Bundy, R.M.; Carrasco, G.; Croot, P.L.; Garnier, C.; Gerringa, L.J.A.; Gledhill, M.; Hirose, K.; Kondo, Y.; Laglera, L.M.; Nuester, J.; Rijkenberg, M.J.A.; Takeda, S.; Twining, B.S.; Wells, M.

    2015-01-01

    With the common goal of more accurately and consistently quantifying ambient concentrations of free metal ions and natural organic ligands in aquatic ecosystems, researchers from 15 laboratories that routinely analyze trace metal speciation participated in an intercomparison of statistical methods

  4. Report on intercomparison V-9 of the determination of trace elements in cotton cellulose

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1983-03-01

    Trace elements in plants are being investigated in many laboratories using nuclear techniques, mainly neutron activation analysis. To enable these laboratories to check the accuracy of their work and to provide data needed in the certification of a batch of reference material, the IAEA has organized several intercomparisons of analytical results of plants. This report deals with the comparative evaluations of the results on cotton cellulose powder. A total of 27 laboratories from 19 countries submitted 377 laboratory means on 57 elements

  5. Report on the intercomparison run IAEA-312 Ra-226, Th and U in soil

    International Nuclear Information System (INIS)

    Strachnov, V.; Valkovic, V.; Zeisler, R.; Dekner, R.

    1991-01-01

    This report contains the results of the intercomparison IAEA-312 on the determination of uranium, thorium and Ra-226 in an Indonesian soil sample. The participants included 39 laboratories located in 17 countries, and statistical evaluation of their data yield recommended values for these elements. The elements, their recommended values and confidence intervals are: Ra-226, 269 Bq/kg (250-287); Th, 91.4 microg/g (81.3-101.5); U, 16.5 microg/g (15.7-17.4). Tabs

  6. Report on the intercomparison run IAEA-321 radionuclides in milk powder

    International Nuclear Information System (INIS)

    Strachnov, V.; Burns, K.; Dekner, R.

    1990-01-01

    This report contains the results of the intercomparison IAEA-321 on the determination of radionuclides in milk powder. Initially participants were requested to determine the levels of 134 Cs, 137 Cs, 40 K, 90 Sr and invited to provide data for other radionuclides. The participants included 61 laboratories located in 29 countries, and statistical evaluation of their data yield recommended values for these four radionuclides. Additional radionuclides reported were 226 Ra and 232 Th, however insufficient data exists to statistically determine recommended values for these radionuclides. The recommended values for radionuclide determination are: 134 Cs: 15.5 Bq/kg; 137 Cs: 72.6 Bq/Kg; 40 K: 552 Bq/kg; 90 Sr: 3.3 Bq/kg. Tabs

  7. Intercomparison of personal radiation monitoring services in the Asia/Pacific region

    International Nuclear Information System (INIS)

    Young, J.G.; Hargrave, N.J.

    1994-01-01

    The Australian Radiation Laboratory conducted an international intercomparison of personal radiation monitoring services in the Asia/Pacific region during 1991. Twenty nine organizations from sixteen countries took part in the study, with the People's Republic of China having eleven participants. Dosemeters incorporating thermoluminescent phosphors and conventional film were submitted for evaluation. Both types were irradiated at normal incidence on a phantom with 137 Cs gamma rays, X rays and beta radiation from a 90 Sr/ 90 Y source. Participants were requested to assess their dosemeters in terms of the new operational quantities of the ICRU for personal radiation monitoring, in particular the personal dose equivalents H p (0.07) and H p (10). (author)

  8. The Agriculture Model Intercomparison and Improvement Project (AgMIP) (Invited)

    Science.gov (United States)

    Rosenzweig, C.

    2010-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation exercise for historical model intercomparison and future climate change conditions with participation of multiple crop and world agricultural trade modeling groups around the world. The goals of AgMIP are to improve substantially the characterization of risk of hunger and world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. Historical period results will spur model improvement and interaction among major modeling groups, while future period results will lead directly to tests of adaptation and mitigation strategies across a range of scales. AgMIP will consist of a multi-scale impact assessment utilizing the latest methods for climate and agricultural scenario generation. Scenarios and modeling protocols will be distributed on the web, and multi-model results will be collated and analyzed to ensure the widest possible coverage of agricultural crops and regions. AgMIP will place regional changes in agricultural production in a global context that reflects new trading opportunities, imbalances, and shortages in world markets resulting from climate change and other driving forces for food supply. Such projections are essential inputs from the Vulnerability, Impacts, and Adaptation (VIA) research community to the Intergovernmental Panel on Climate Change Fifth Assessment (AR5), now underway, and the UN Framework Convention on Climate Change. They will set the context for local-scale vulnerability and adaptation studies, supply test scenarios for national-scale development of trade policy instruments, provide critical information on changing supply and demand for water resources, and elucidate interactive effects of climate change and land use change. AgMIP will not only provide crucially-needed new global estimates of how climate change will affect food supply and hunger in the

  9. Blind intercomparison of nuclear models for predicting charged particle emission

    International Nuclear Information System (INIS)

    Shibata, K.; Cierjacks, S.

    1994-01-01

    Neutron activation data are important for dosimetry, radiation-damage and production of long-lived activities. For fusion energy applications, it is required to develop 'low-activation materials' from the viewpoints of safety, maintenance and waste disposal. Existing evaluated activation cross-section libraries are to a large extent based on nuclear-model calculations. The former Nuclear Energy Agency Nuclear Data Committee, NEANDC, (presently replaced by the NEA Nuclear Science Committee) organized the working group on activation cross sections. The first meeting of the group was held in 1989, and it was then agreed that a blind intercomparison of nuclear-model calculations should be undertaken in order to test the predictive power of the theoretical calculations. As a first stage the working group selected the reactions 60g Co(n,p) 60 Fe and 60m Co(n,p) 60 Fe, for which no experimental data were available, in the energy range from 1 to 20 MeV. The preliminary results compiled at the NEA Data Bank were sent to each participant and a meeting was held during the International Conference on Nuclear Data for Science and Technology in Julich 1991 to discuss the results. Following the outcome of the discussion in Julich, it was decided to extend this intercomparison. In the second-stage calculation, the same optical-model parameters were employed for neutrons, protons and α-particles, i.e., V = 50 MeV, W = 10 MeV, r = 1.25 fm and a = 0.6 fm with the Woods-Saxon volume-type form factors. No spin-orbit interaction was considered. Concerning the level density, the Fermi gas model with a = A/8 MeV -1 was assumed without pairing corrections. Moreover, gamma-ray competition was neglected to simplify the calculation. This report describes the final results of the blind comparison. Section 2 deals with a survey of the received contributions. The final results are graphically presented in section 3. 67 figs., 1 tab., 12 refs

  10. ACTRIS ACSM intercomparison - Part 2: Intercomparison of ME-2 organic source apportionment results from 15 individual, co-located aerosol mass spectrometers

    Science.gov (United States)

    Fröhlich, R.; Crenn, V.; Setyan, A.; Belis, C. A.; Canonaco, F.; Favez, O.; Riffault, V.; Slowik, J. G.; Aas, W.; Aijälä, M.; Alastuey, A.; Artiñano, B.; Bonnaire, N.; Bozzetti, C.; Bressi, M.; Carbone, C.; Coz, E.; Croteau, P. L.; Cubison, M. J.; Esser-Gietl, J. K.; Green, D. C.; Gros, V.; Heikkinen, L.; Herrmann, H.; Jayne, J. T.; Lunder, C. R.; Minguillón, M. C.; Močnik, G.; O'Dowd, C. D.; Ovadnevaite, J.; Petralia, E.; Poulain, L.; Priestman, M.; Ripoll, A.; Sarda-Estève, R.; Wiedensohler, A.; Baltensperger, U.; Sciare, J.; Prévôt, A. S. H.

    2015-06-01

    Chemically resolved atmospheric aerosol data sets from the largest intercomparison of the Aerodyne aerosol chemical speciation monitors (ACSMs) performed to date were collected at the French atmospheric supersite SIRTA. In total 13 quadrupole ACSMs (Q-ACSM) from the European ACTRIS ACSM network, one time-of-flight ACSM (ToF-ACSM), and one high-resolution ToF aerosol mass spectrometer (AMS) were operated in parallel for about 3 weeks in November and December~2013. Part 1 of this study reports on the accuracy and precision of the instruments for all the measured species. In this work we report on the intercomparison of organic components and the results from factor analysis source apportionment by positive matrix factorisation (PMF) utilising the multilinear engine 2 (ME-2). Except for the organic contribution of mass-to-charge ratio m/z 44 to the total organics (f44), which varied by factors between 0.6 and 1.3 compared to the mean, the peaks in the organic mass spectra were similar among instruments. The m/z 44 differences in the spectra resulted in a variable f44 in the source profiles extracted by ME-2, but had only a minor influence on the extracted mass contributions of the sources. The presented source apportionment yielded four factors for all 15 instruments: hydrocarbon-like organic aerosol (HOA), cooking-related organic aerosol (COA), biomass burning-related organic aerosol (BBOA) and secondary oxygenated organic aerosol (OOA). ME-2 boundary conditions (profile constraints) were optimised individually by means of correlation to external data in order to achieve equivalent / comparable solutions for all ACSM instruments and the results are discussed together with the investigation of the influence of alternative anchors (reference profiles). A comparison of the ME-2 source apportionment output of all 15 instruments resulted in relative standard deviations (SD) from the mean between 13.7 and 22.7 % of the source's average mass contribution depending on the

  11. SOIL moisture data intercomparison

    Science.gov (United States)

    Kerr, Yann; Rodriguez-Frenandez, Nemesio; Al-Yaari, Amen; Parens, Marie; Molero, Beatriz; Mahmoodi, Ali; Mialon, Arnaud; Richaume, Philippe; Bindlish, Rajat; Mecklenburg, Susanne; Wigneron, Jean-Pierre

    2016-04-01

    The Soil Moisture and Ocean Salinity satellite (SMOS) was launched in November 2009 and started delivering data in January 2010. Subsequently, the satellite has been in operation for over 6 years while the retrieval algorithms from Level 1 to Level 2 underwent significant evolutions as knowledge improved. Other approaches for retrieval at Level 2 over land were also investigated while Level 3 and 4 were initiated. In this présentation these improvements are assessed by inter-comparisons of the current Level 2 (V620) against the previous version (V551) and new products either using neural networks or Level 3. In addition a global evaluation of different SMOS soil moisture (SM) products is performed comparing products with those of model simulations and other satellites (AMSR E/ AMSR2 and ASCAT). Finally, all products were evaluated against in situ measurements of soil moisture (SM). The study demonstrated that the V620 shows a significant improvement (including those at level1 improving level2)) with respect to the earlier version V551. Results also show that neural network based approaches can yield excellent results over areas where other products are poor. Finally, global comparison indicates that SMOS behaves very well when compared to other sensors/approaches and gives consistent results over all surfaces from very dry (African Sahel, Arizona), to wet (tropical rain forests). RFI (Radio Frequency Interference) is still an issue even though detection has been greatly improved while RFI sources in several areas of the world are significantly reduced. When compared to other satellite products, the analysis shows that SMOS achieves its expected goals and is globally consistent over different eco climate regions from low to high latitudes and throughout the seasons.

  12. Historical and idealized climate model experiments: an EMIC intercomparison

    DEFF Research Database (Denmark)

    Eby, M.; Weaver, A. J.; Alexander, K.

    2012-01-01

    Both historical and idealized climate model experiments are performed with a variety of Earth System Models of Intermediate Complexity (EMICs) as part of a community contribution to the Intergovernmental Panel on Climate Change Fifth Assessment Report. Historical simulations start at 850 CE...... and continue through to 2005. The standard simulations include changes in forcing from solar luminosity, Earth's orbital configuration, CO2, additional greenhouse gases, land-use, and sulphate and volcanic aerosols. In spite of very different modelled pre-industrial global surface air temperatures...... the Medieval Climate Anomaly and the Little Ice Age estimated from paleoclimate reconstructions. This in turn could be a result of errors in the reconstructions of volcanic and/or solar radiative forcing used to drive the models or the incomplete representation of certain processes or variability within...

  13. Historical and idealized climate model experiments: an EMIC intercomparison

    DEFF Research Database (Denmark)

    Eby, M.; Weaver, A. J.; Alexander, K.

    2012-01-01

    Both historical and idealized climate model experiments are performed with a variety of Earth System Models of Intermediate Complexity (EMICs) as part of a community contribution to the Intergovernmental Panel on Climate Change Fifth Assessment Report. Historical simulations start at 850 CE......, are used to assess the contributions of different climate forcings to the overall climate and carbon cycle response. The response of surface air temperature is the linear sum of the individual forcings, while the carbon cycle response shows considerable synergy between land-use change and CO2... and continue through to 2005. The standard simulations include changes in forcing from solar luminosity, Earth's orbital configuration, CO2, additional greenhouse gases, land-use, and sulphate and volcanic aerosols. In spite of very different modelled pre-industrial global surface air temperatures...

  14. Intercomparison study of atmospheric methane and carbon dioxide concentrations measured at the Ebre River Delta Station

    Science.gov (United States)

    Occhipinti, Paola; Morguí, Josep Anton; Àgueda, Alba; Batet, Oscar; Borràs, Sílvia; Cañas, Lídia; Curcoll, Roger; Grossi, Claudia; Nofuentes, Manel; Vazquez, Eusebi; Rodó, Xavier

    2015-04-01

    In the framework of the ClimaDat project, IC3 has established a network of eight monitoring stations across the Iberian Peninsula and the Canarian Archipelago with the aim of studying climate processes. The monitoring station at the Ebre River Delta (DEC3) is located in the Ebre River Delta Natural Park (40° 44' N; 0° 47' E) and it is characterized by the typical North-Western Mediterranean climate. Since 2013, atmospheric greenhouse gases (GHG) and 222Rn tracer gas together with the meteorological parameters are continuously measured from a 10 m a.g.l. height tower. Atmospheric GHG (CO2, CH4, CO and N2O) concentrations are determined using a Picarro analyzer G2301 (CO2 and CH4) and a modified gas chromatograph (GC) Agilent 6890N (CO2, CH4, CO and N2O). Open data access is available from the www.climadat.es website. Data collected at the DEC3 station are also submitted to the InGOS platform since this station is part of the InGOS European infrastructure project. Researchers from the Laboratory of the Atmosphere and the Oceans (LAO) at IC3 have performed an intercomparison study at the DEC3 site between three different Picarro analyzers (two Picarro G2301 and one Picarro G2301M), a Los Gatos Research (LGR) analyzer and the GC system already installed at the station. The aim of this study is to compare and assess the measuring agreement between the four optical gas analyzers and the GC. In the first part of the experiment, all instruments have been calibrated using NOAA gases as primary standards analyzing five Praxair provided targets to evaluate the precision of the measuring instruments. Max Plank Institute (MPI) gases have been used as secondary standards for the GC whereas Praxair provided tanks are used as secondary standards for the Picarro and the LGR analyzers. In the second part of the experiment, atmospheric GHG were measured from natural atmospheric air taken from a 10 m a.g.l. inlet. Daily cycles of GHG measurements were carried out using different

  15. World-wide and regional intercomparison for the determination of organochlorine compounds and petroleum hydrocarbons in mussel sample IAEA-142. Report no. 59

    International Nuclear Information System (INIS)

    Villeneuve, J.P.; Horvat, M.; Cattini, C.

    1996-03-01

    The accurate and precise determination of organochlorine compounds and petroleum hydrocarbons in marine environmental samples is an important aspect of marine pollution assessments in coastal and ocean environments. Intercomparison exercises represent an essential element of method testing and are used as a basic tool for evaluating data quality on a global and regional level. The Marine Environmental Studies Laboratory (MESL) of IAEA-MEL has conducted intercomparison exercises on trace organic compounds for over nineteen years as part of its contribution to IAEA's analytical quality control service and UNEP's regional seas programme, and occasionally in association with the intergovernmental oceanographic commission (of UNESCO) GIPME programme. These exercises are organized on a continuous basis, at least once per year. Result of previous exercises have revealed serious problems for many regional laboratories to obtain comparable data. As a consequence of this situation, it was decided to seek increased support for quality assurance programmes. Staff of MESL, with funding from UNEP, the World Bank and regional trust funds, embarked on a campaign to train analysts in modern measurement techniques, supply appropriate and reliable reference methods and materials and, where possible, to improve analytical instruments in Member State laboratories. This report describes results of the IAEA/UNEP intercomparison run 142 for the chemical analysis of organochlorine compounds and petroleum hydrocarbons in a homogenised mussel sample

  16. International intercomparison of environmental dosimeters under field and laboratory conditions

    International Nuclear Information System (INIS)

    Gesell, T.F.; de Planque Burke, G.; Becker, K.

    1975-04-01

    Based on the results of a pilot study at ORNL in 1973, a more comprehensive international intercomparison of integrating dosimeters for the assessment of external penetrating environmental radiation fields was carried out. Forty-one laboratories from eleven countries participated in this study. A total of 56 sets of six detectors each were mailed to and from Houston, Texas, where they were exposed for three months (July to September 1974) as follows: two in an unprotected space out-of-doors 1 m above ground; two in an air-conditioned shielded area with a known, low exposure rate; and two with the second group, but with an additional exposure to 30 mR. Evaluation of the dosimeters provides information on the calibration precision, the accuracy of field measurement, and transit exposure. Results are discussed. (U.S.)

  17. Intercomparison between BATS and LSPM surface schemes, using point micrometeorological data set

    Energy Technology Data Exchange (ETDEWEB)

    Ruti, P.M.; Cacciamani, C.; Paccagnella, T. [Servizio Meteorologico Regionale, Bologna (Italy); Cassardo, C. [Turin Univ., Alessandria (Italy). Dipt. di Scienze e Technologie Avanzate; Longhetto, A. [Turin Univ. (Italy). Ist. di Fisica Generale; Bargagli, A. [ENEA, Roma (Italy). Gruppo di Dinamica dell`Atmosfera e dell`Oceano

    1997-08-01

    This work has been developed with the aim to create an archive of climatological values of sensible, latent and ground-atmosphere heat fluxes in the Po valley (CLIPS experiment); due to the unavailability of climatological archives of turbulent fluxes at synoptic scale, we have used the outputs of ``stand-alone`` runnings of biospheric models; this archive could be used to check the parametrizations of large- and mesoscale models in the surface layer. We started to check the reliability of our proposal by testing the model outputs by a comparison with observed data. We selected a flat, rural area in the middle-east Po valley (San Pietro Capofiume, Italy) and used the data gathered in the experimental campaign SPCFLUX93 carried out there. The models adopted for the intercomparison have been the biosphere-atmosphere transfer scheme (BATS) of Dickinson et al. (1986 version) and the land surface process model (LSPM) of Cassardo et al. (1996 version). An improved version of BATS has been implemented by us changing in a substantial way the soil thermal and hydrological subroutines. The upper boundary conditions used for all models were taken by interpolating the synoptic observations carried out at San Pietro Capofiume (Italy) station; the algorithm used for the interpolations was tested with the data achieved in a fortnight campaign (SPCFLUX93) carried out at the same location during June 1993, showing a good agreement between interpolated and observed variables. Two experiments have been carried out; in the first one, the vegetation parameter set used by BATS has been used to force all models, while in the second one a vegetation cover value closest to the observations in the site has been used. 30 refs.

  18. EURADOS intercomparisons on whole body and extremity dosemeters (2008–2009) – Results and comparison of different dosemeter designs

    International Nuclear Information System (INIS)

    Stadtmann, H.; Grimbergen, T.W.M.; Figel, M.; Romero, A.M.; Mcwhan, A.F.

    2011-01-01

    The EURADOS (European Radiation Dosimetry Group) working group (WG2) on Harmonisation of Individual Monitoring in Europe has shown that intercomparisons are fundamental for harmonisation of individual monitoring. As a result of these considerations, EURADOS started to prepare a series of continuous intercomparisons for individual monitoring services (IMS) in Europe. EURADOS has now successfully executed two intercomparison exercises, one for whole body dosemeters (2008) and one for extremity dosemeters (2009). Both exercises were performed without external funding, all costs being covered by the participants’ fees. More than 120 (!) different – mainly passive – dosimetry systems were tested from all over Europe until now and the results were analysed and compared. Although scientific studies were not the primary objective of these exercises specific additional information about the tested systems supplied by the participants for statistical analysis allows a detailed analysis of these results with respect to different parameters like dosemeter type, detector material, filter thickness or others design parameters. The influence of such parameters on the response values of the dosemeters is analysed and discussed in this paper. Both energy response as well as directional response for beta and photon radiation are considered. The influence of different design parameters e.g. detector material, is analysed by comparing the frequency distribution of the response values for different dosemeter groups. Pronounced differences for different detector materials (LiF:Mg,Ti, LiF:Mg,Cu,P and Li 2 B 4 O 7 /CaSO 4 ) were found. The paper gives a comprehensive overview on the performance of various European dosimetry services and the influence of the dosemeter design on the resulting response values.

  19. Intercomparison for individual monitoring of external exposure from photon radiation. Results of a co-ordinated research project 1996-1998

    International Nuclear Information System (INIS)

    1999-12-01

    This TECDOC presents the results of a Co-ordinated Research Project on Intercomparison for Individual Monitoring of External Exposure from photon radiation. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) have endorsed the use of the operational quantities for monitoring purposes. Specifically, personal dose equivalent, H p (d), is to be used for individual dosimetry to demonstrate compliance with the exposure limit recommendations, while for workplace area monitoring the ambient dose equivalent and the directional dose equivalent are recommended. In view of the technical difficulties associated with the introduction of these operational quantities the IAEA decided to assist Member States in their provision of appropriate dosimetry for occupational protection. In this respect, intercomparisons have proven to be a cost effective method of providing such support. A Co-ordinated Research Project (CRP) was started in 1997 on Intercomparison for Individual Monitoring of External Exposure from photon radiation, involving more than twenty laboratories from eastern Europe and the countries of the former Soviet Union, and focusing on personnel dosimetry services for nuclear power plants. This CRP was part of the activities of the IAEA Occupational Protection Programme, the objective4s of which are to promote and internationally harmonized approach for optimizing occupational radiation protection through: the development of guides, within the IAEA activities for establishing standards for radiation protection, for restricting radiation exposures in the workplace and for applying current occupational radiation protection techniques, and the promotion of the application of these guidelines. The preparatory phase included, in May 1997, a workshop aimed at familiarizing the participants with the new operational quantities

  20. Report on intercomparison exercise SR-64. Determination of impurities in U3O8

    International Nuclear Information System (INIS)

    Doubek, N.; Bagliano, G.; Deron, S.

    1985-04-01

    The report presents results of a laboratory intercomparison of the determination of impurities in U 3 O 8 samples. 38 different elements were analyzed by the laboratories which participated in the SR-64 exercise. At the issue of the exercise it was possible to provide recommended values for 8 elements. The content of 11 other elements could be assigned as information values. Seven different techniques of analyses were used but 29% of the results were obtained by flame atomic absorption and 69% by emission spectrography

  1. Coordinated research efforts for establishing an international radiotherapy dose intercomparison service based on the alanine/ESR system

    International Nuclear Information System (INIS)

    Nette, H.P.; Onori, S.; Fattibene, P.; Regulla, D.; Wieser, A.

    1993-01-01

    The IAEA has long been active in the field of high-dose standardization. An International Dose Assurance Service (IDAS) was established based on alanine/ESR dosimetry. This service operates over the range of 100 Gy to 100 kGy and is directed towards industrial radiation processing in IAEA member states. It complements the IAEA/WHO TLD postal dose intercomparison service for dose assurance in hospital radiotherapy departments. Experience with the alanine high dose service suggests that the alanine dosimeter might provide superior performance to TLD in the therapy dose range. Preliminary test measurements with the participation of GSF/Germany, Istituto Superiore di Sanita/Italy (both providing alanine dosimeters and their evaluation) and IAEA (providing reference irradiations) seems to justify research efforts through an IAEA Coordinated Research Programme (CRP). This CRP, entitled ''Therapy Level Dosimetry with the Alanine/ESR System'' is presently under set-up. It will include general work common to all assigned/potential contract holders as well as some specific research topics in accordance to individual proposals of each participant. (author)

  2. The Agricultural Model Intercomparison and Improvement Project (AgMIP): Progress and Preliminary Results

    Science.gov (United States)

    Rosenzweig, C.

    2011-12-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) is a distributed climate-scenario simulation exercise for historical model intercomparison and future climate change conditions with participation of multiple crop and agricultural trade modeling groups around the world. The goals of AgMIP are to improve substantially the characterization of risk of hunger and world food security due to climate change and to enhance adaptation capacity in both developing and developed countries. Recent progress and the current status of AgMIP will be presented, highlighting three areas of activity: preliminary results from crop pilot studies, outcomes from regional workshops, and emerging scientific challenges. AgMIP crop modeling efforts are being led by pilot studies, which have been established for wheat, maize, rice, and sugarcane. These crop-specific initiatives have proven instrumental in testing and contributing to AgMIP protocols, as well as creating preliminary results for aggregation and input to agricultural trade models. Regional workshops are being held to encourage collaborations and set research activities in motion for key agricultural areas. The first of these workshops was hosted by Embrapa and UNICAMP and held in Campinas, Brazil. Outcomes from this meeting have informed crop modeling research activities within South America, AgMIP protocols, and future regional workshops. Several scientific challenges have emerged and are currently being addressed by AgMIP researchers. Areas of particular interest include geospatial weather generation, ensemble methods for climate scenarios and crop models, spatial aggregation of field-scale yields to regional and global production, and characterization of future changes in climate variability.

  3. Intercomparison of slant column measurements of NO₂ and O₄ by MAX-DOAS and zenith-sky UV and visible spectrometers

    NARCIS (Netherlands)

    Roscoe, H.K.; Roozendael, Van M.; Fayt, C.; Piesanie, du A.; Abuhassan, N.; Adams, C.; Akrami, M.; Cede, A.; Chong, J.; Clémer, K.; Friess, U.; Gil Ojeda, M.; Goutail, F.; Graves, R.; Griesfeller, A.; Grossmann, K.; Hemerijckx, G.; Hendrick, F.; Herman, J.; Hermans, C.; Irie, H.; Johnston, P.V.; Kanaya, Y.; Kreher, K.; Leigh, R.; Merlaud, A.; Mount, G.H.; Navarro, M.; Oetjen, H.; Pazmino, A.; Perez-Camacho, M.; Peters, E.; Pinardi, G.; Puentedura, O.; Richter, A.; Schönhardt, A.; Shaiganfar, R.; Spinei, E.; Strong, K.; Takashima, H.; Vlemmix, T.; Vrekoussis, M.; Wagner, T.; Wittrock, F.; Yela, M.; Yilmaz, S.S.; Boersma, K.F.; Hains, J.C.; Kroon, M.; Piters, A.J.M.; Kim, Y.J.

    2010-01-01

    In June 2009, 22 spectrometers from 14 institutes measured tropospheric and stratospheric NO2 from the ground for more than 11 days during the Cabauw Intercomparison campaign of Nitrogen Dioxide measuring Instruments (CINDI), at Cabauw, NL (51.97° N, 4.93° E). All visible instruments used a common

  4. Assessment of Intercomparison of Radionuclide Activity Measurement between P3KRBiN-BATAN and NMIJ/AIST-JAPAN

    International Nuclear Information System (INIS)

    Nazaroh; Pujadi; Hermawan Candra; Ermi Juita; Holnisar

    2003-01-01

    On every radionuclide activity measurements or any measurements always contain uncertainties. The uncertainties come from standard source, equipment to be used, condition of measurements (background) and sample (measurement). Those elements should be taken into account in the measurement result evaluation. To know the result of activity measurement was in a good agreement or not, it can be done by intercomparison. A good result of a measurement if it was nearly with the result of international/primary laboratories measurements such as System Internationale de Reference (SIR)-Franch, National Metrology Institute of Japan- Advanced Industrial Science and Technology (NMIJ/AIST or Physikalisch Technische Bundes-anstalt (PTB) and the absolute value of E n should be less than 1. The result of intercomparison between Center for Research and Development of Radiation Safety and Nuclear Biomedicine (P3KRBiN) -BATAN and NMIJ/AIST were in a good agreement for activity measurement of 125 I (E n =0.193), 58 Co(E n =0.503), 88 Y(E n =0.035) and 59 Fe(E n =0.632), by using gamma spectrometry counting system (HPGe detector) and 166m Ho(E n =0.492), by using Merlin Gerin Ionization chamber. (author)

  5. Intercomparison of measurements of personal dose equivalent Hp(10) in photon fields in the West Asia Region

    International Nuclear Information System (INIS)

    2007-01-01

    In accordance with its statutory function, the International Atomic Energy Agency (IAEA) has been assisting its Member States in establishing and upgrading their radiation protection infrastructures, including activities in occupation radiation protection. Individual external dosimetry services for photon radiation have been under establishment or upgrading with support through the Technical Cooperation Model Projects RAW/9/006, Upgrading Radiation Protection Infrastructure (concluded in 2000), and RAW/9/008, Development of Technical Capabilities for Sustainable Radiation and Waste Safety Infrastructure (2001-2004), in all the participating countries in the West Asia Region. Two regional training courses were organized by the IAEA, in Germany in 1998, on Design, Implementation and Management of Individual Monitoring Services (IMS), and in the Syrian Arabic Republic in 2001, on Assessment of Occupational Exposure due to External Sources, under the above stated projects. However, no performance testing has yet been carried out and no regional intercomparisons have been established before in this region. Only two Member States from the region (the Syrian Arab Republic and Lebanon) participated in the interregional Intercomparison for Individual Monitoring of Radiological Measurements for Purposes of Monitoring Personal Dose Equivalent Hp(10) in 1999

  6. A multi-model intercomparison of halogenated very short-lived substances (TransCom-VSLS): linking oceanic emissions and tropospheric transport for a reconciled estimate of the stratospheric source gas injection of bromine

    OpenAIRE

    Hossaini, R.; Patra, P. K.; Leeson, A. A.; Krysztofiak, G.; Abraham, N. L.; Andrews, S. J.; Archibald, A. T.; Aschmann, J.; Atlas, E. L.; Belikov, D. A.; Bonisch, H.; Carpenter, L. J.; Dhomse, S.; Dorf, M.; Engel, A.

    2016-01-01

    The first concerted multi-model intercomparison of halogenated very short-lived substances (VSLS) has been performed, within the framework of the ongoing Atmospheric Tracer Transport Model Intercomparison Project (TransCom). Eleven global models or model variants participated (nine chemical transport models and two chemistry–climate models) by simulating the major natural bromine VSLS, bromoform (CHBr3) and dibromomethane (CH2Br2), over a 20-year period (1993–2012). Except f...

  7. WCRP COordinated Regional Downscaling EXperiment (CORDEX: a diagnostic MIP for CMIP6

    Directory of Open Access Journals (Sweden)

    W. J. Gutowski Jr.

    2016-11-01

    Full Text Available The COordinated Regional Downscaling EXperiment (CORDEX is a diagnostic model intercomparison project (MIP in CMIP6. CORDEX builds on a foundation of previous downscaling intercomparison projects to provide a common framework for downscaling activities around the world. The CORDEX Regional Challenges provide a focus for downscaling research and a basis for making use of CMIP6 global climate model (GCM output to produce downscaled projected changes in regional climates and assess sources of uncertainties in the projections, all of which can potentially be distilled into climate change information for vulnerability, impacts and adaptation studies. CORDEX Flagship Pilot Studies advance regional downscaling by targeting one or more of the CORDEX Regional Challenges. A CORDEX-CORE framework is planned that will produce a baseline set of homogeneous high-resolution, downscaled projections for regions worldwide. In CMIP6, CORDEX coordinates with ScenarioMIP and is structured to allow cross comparisons with HighResMIP and interaction with the CMIP6 VIACS Advisory Board.

  8. The Cloud Feedback Model Intercomparison Project Observational Simulator Package: Version 2

    Science.gov (United States)

    Swales, Dustin J.; Pincus, Robert; Bodas-Salcedo, Alejandro

    2018-01-01

    The Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP) gathers together a collection of observation proxies or satellite simulators that translate model-simulated cloud properties to synthetic observations as would be obtained by a range of satellite observing systems. This paper introduces COSP2, an evolution focusing on more explicit and consistent separation between host model, coupling infrastructure, and individual observing proxies. Revisions also enhance flexibility by allowing for model-specific representation of sub-grid-scale cloudiness, provide greater clarity by clearly separating tasks, support greater use of shared code and data including shared inputs across simulators, and follow more uniform software standards to simplify implementation across a wide range of platforms. The complete package including a testing suite is freely available.

  9. Intercomparison of radionuclide measurements in Baltic Sea water sample IAEA-299

    International Nuclear Information System (INIS)

    Ballestra, S.; Lopez, J.J.

    1993-03-01

    This report contains the results of the intercomparison exercise on IAEA-299 for the determination of 90 Sr, 134 Cs and 137 Cs concentration in Baltic Sea Water. The participants belong to 8 laboratories located in 6 countries, members of the Helsinki commission. Statistical evaluation of the data reported yields to recommended values for these elements. The elements, their recommended values and confidence intervals are listed here: 90 Sr: 13.6 Bq kg -1 (12.8-14.4); 134 Cs: 6.7 Bq kg -1 (5-8.3); 137 Cs: 70.9 Bq kg -1 (68-72.3). Reference date: 27 June 1991 (sampling date). The data reported by the laboratories of the Baltic Sea States are generally in very good agreement. (author)

  10. Intercomparison of radionuclides measurements in marine cockle flesh sample IAEA-134

    International Nuclear Information System (INIS)

    Ballestra, S.; Gastaud, J.; Lopez, J.J.; Parsi, P.; Vas, D.

    1993-08-01

    The results of an intercomparison exercise on a cockle flesh sample from Irish Sea, IAEA-134, designed for the determination of artificial and natural radionuclide levels, are reported. The data from 134 laboratories representing 49 countries have been evaluated. The following are the recommended values, with confidence intervals, for 40 K, 60 Co, 137 Cs, and 2 39+240 Pu (Reference date: 1 January 1992). Information values for 90 Sr, 106 Ru, 125 Sb, 134 Cs, 154 Eu, 155 Eu, 210 Pb, 210 Po, 226 Ra, 228 Ra, 228 Th, 230 Th, 232 Th, 234 U, 235 U, 238 U, 238 Pu and 241 Am are also reported. All the following values are expressed in Bq kg -1 (dry weight). (author)

  11. Intercomparison of passive radon-detectors under field conditions in epidemiological studies.

    Science.gov (United States)

    Kreienbrock, L; Poffijn, A; Tirmarche, M; Feider, M; Kies, A; Darby, S C

    1999-05-01

    The Ardennes and Eifel region is a geologically distinct area covering parts of Germany, Belgium, France, and Luxembourg where enhanced concentrations of radon occur in some houses and other buildings. An international case-control study is being conducted to examine the role of radon in the etiology of lung cancer in this area. The radon detectors used are issued by different laboratories involving a variety of detector types and processes. A series of intercomparisons in houses was therefore conducted under similar conditions of exposure in the field. In most situations the different detectors gave similar results. Nevertheless, in some situations open and closed detectors yielded different results. Therefore, estimates of radon exposure have to be adjusted if results are to be pooled.

  12. Next Generation Climate Change Experiments Needed to Advance Knowledge and for Assessment of CMIP6

    Energy Technology Data Exchange (ETDEWEB)

    Katzenberger, John [Aspen Global Change Inst., Basalt, CO (United States); Arnott, James [Aspen Global Change Inst., Basalt, CO (United States); Wright, Alyson [Aspen Global Change Inst., Basalt, CO (United States)

    2014-10-30

    The Aspen Global Change Institute hosted a technical science workshop entitled, “Next generation climate change experiments needed to advance knowledge and for assessment of CMIP6,” on August 4-9, 2013 in Aspen, CO. Jerry Meehl (NCAR), Richard Moss (PNNL), and Karl Taylor (LLNL) served as co-chairs for the workshop which included the participation of 32 scientists representing most of the major climate modeling centers for a total of 160 participant days. In August 2013, AGCI gathered a high level meeting of representatives from major climate modeling centers around the world to assess achievements and lessons learned from the most recent generation of coordinated modeling experiments known as the Coupled Model Intercomparison Project – 5 (CMIP5) as well as to scope out the science questions and coordination structure desired for the next anticipated phase of modeling experiments called CMIP6. The workshop allowed for reflection on the coordination of the CMIP5 process as well as intercomparison of model results, such as were assessed in the most recent IPCC 5th Assessment Report, Working Group 1. For example, this slide from Masahiro Watanabe examines performance on a range of models capturing Atlantic Meridional Overturning Circulation (AMOC).

  13. Third EU MAT intercomparison on methods for the determination of vitamins B-1, B-2 and B-6 in food

    NARCIS (Netherlands)

    Berg, H. van den; Schaik, F. van; Finglas, P.M.; Froidmont-Görtz, I. de

    1996-01-01

    An intercomparison study on the determination of vitamin B-1, B-2 and B-6 was performed as part of the EU MAT project involving 16 laboratories. Each laboratory was requested to analyse three different food samples (lyophilized pig's liver, mixed vegetables and wholemeal flour, respectively) using

  14. ACTRIS ACSM intercomparison – Part 2: Intercomparison of ME-2 organic source apportionment results from 15 individual, co-located aerosol mass spectrometers

    Directory of Open Access Journals (Sweden)

    R. Fröhlich

    2015-06-01

    Full Text Available Chemically resolved atmospheric aerosol data sets from the largest intercomparison of the Aerodyne aerosol chemical speciation monitors (ACSMs performed to date were collected at the French atmospheric supersite SIRTA. In total 13 quadrupole ACSMs (Q-ACSM from the European ACTRIS ACSM network, one time-of-flight ACSM (ToF-ACSM, and one high-resolution ToF aerosol mass spectrometer (AMS were operated in parallel for about 3 weeks in November and December~2013. Part 1 of this study reports on the accuracy and precision of the instruments for all the measured species. In this work we report on the intercomparison of organic components and the results from factor analysis source apportionment by positive matrix factorisation (PMF utilising the multilinear engine 2 (ME-2. Except for the organic contribution of mass-to-charge ratio m/z 44 to the total organics (f44, which varied by factors between 0.6 and 1.3 compared to the mean, the peaks in the organic mass spectra were similar among instruments. The m/z 44 differences in the spectra resulted in a variable f44 in the source profiles extracted by ME-2, but had only a minor influence on the extracted mass contributions of the sources. The presented source apportionment yielded four factors for all 15 instruments: hydrocarbon-like organic aerosol (HOA, cooking-related organic aerosol (COA, biomass burning-related organic aerosol (BBOA and secondary oxygenated organic aerosol (OOA. ME-2 boundary conditions (profile constraints were optimised individually by means of correlation to external data in order to achieve equivalent / comparable solutions for all ACSM instruments and the results are discussed together with the investigation of the influence of alternative anchors (reference profiles. A comparison of the ME-2 source apportionment output of all 15 instruments resulted in relative standard deviations (SD from the mean between 13.7 and 22.7 % of the source's average mass contribution depending on

  15. INTERCOMPARISON OF RESULTS FOR A PWR ROD EJECTION ACCIDENT

    Energy Technology Data Exchange (ETDEWEB)

    DIAMOND,D.J.; ARONSON,A.; JO,J.; AVVAKUMOV,A.; MALOFEEV,V.; SIDOROV,V.; FERRARESI,P.; GOUIN,C.; ANIEL,S.; ROYER,M.E.

    1999-10-01

    This study is part of an overall program to understand the uncertainty in best-estimate calculations of the local fuel enthalpy during the rod ejection accident. Local fuel enthalpy is used as the acceptance criterion for this design-basis event and can also be used to estimate fuel damage for the purpose of determining radiological consequences. The study used results from neutron kinetics models in PARCS, BARS, and CRONOS2, codes developed in the US, the Russian Federation, and France, respectively. Since BARS uses a heterogeneous representation of the fuel assembly as opposed to the homogeneous representations in PARCS and CRONOS, the effect of the intercomparison was primarily to compare different intra-assembly models. Quantitative comparisons for core power, reactivity, assembly fuel enthalpy and pin power were carried out. In general the agreement between methods was very good providing additional confidence in the codes and providing a starting point for a quantitative assessment of the uncertainty in calculated fuel enthalpy using best-estimate methods.

  16. Measurements and validation of parametric schemes. Recent results, Cracow experiment / in the framework of cost - action 715

    Energy Technology Data Exchange (ETDEWEB)

    Godlowska, J.; Tomaszewska, A.M.; Rozwoda, W.; Walczewski, J.; Burzynski, J. [Div. for the Remote Sensing, Cracow (Poland). Inst. of Meteorology and Water Management

    2004-07-01

    In the framework of COST 715 two extensive measurement periods were conducted simultaneously in cities of Katowice and Cracow, Poland (20-25 08.2002 and 10-18 06.2003). The cities influence on the ABL, especially on its MH, was investigated. The measurement sites are located in the city areas. One Urban Meteorological Station is Cracow Czyzyny. This station is located in the middle of the city between two main centres of urbanisation (Old centre of Cracow and new industrial part Nowa Huta), in the green district of the city, on the terrain of the older airport of Cracow. The area is flat, surrounded by numerous trees and bushes. The nearest flat buildings are located more than 300 meters away. The set of devices consisted of two monostatic sodars with Doppler analyses of vertical wind component (30 - 1000 m, second located in Katowice), one Doppler sodar for the determination of the vertical wind profile, a dust lidar, a tethered balloon (profile of wind speed, temperature, humidity), one sonic anemometer mounted 2m above the grass covered surface, a system of three pyrranometers and a semiconductor sensor to determine the heat flux. The special dedicated meteorological automatic station was responsible for the stability class determination (6 traditional classes from A to F, based on implemented, new (2003) categorization scheme dependent on calculated values of Monin- Obukchov Length L). This station measures temperature and the wind speed on the two levels 2 and 10 m each 6 sec, for the L calculations. The measurement equipment was supplemented by standard meteorological measurements in both locations and with a network of meteorological stations in the surrounding areas (also rural representative measurement). The described extended measurements were made mainly in Cracow. The standard measurements and second monostatic sodar were deployed in Katowice. The calculations of the sensible heat flux H schemes for given location were made with use of formulas based

  17. Intercomparison of radionuclide measurements in marine sediment sample IAEA-135

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Gastaud, J; Lopez, J J; Parsi, P; Vas, D

    1993-08-01

    The results of an intercomparison exercise on a marine sediment from Irish Sea, IAEA-135, designed for the determination of artificial and natural radionuclides levels, are reported. The data from 151 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, for {sup 40}K, {sup 60}Co, {sup 134}Cs, {sup 137}Cs, {sup 154}Eu, {sup 155}Eu, {sup 226}Ra, {sup 228}Ra, {sup 232}Th,{sup 238}Pu, {sup 239+240}Pu (Reference date: 1 January 1992). Information values for {sup 57}Co, {sup 90}Sr, {sup 106}Ru, {sup 125}Sb, {sup 210}Pb, {sup 210}Po, {sup 228}Th, {sup 230}Th, {sup 234}U, {sup 235}U, {sup 238}U and {sup 241}Am are also reported. All values are expressed in Bq kg{sup -1} dry weight. (author)

  18. Fifteenth nuclear accident dosimetry intercomparison study: August 14--22, 1978

    International Nuclear Information System (INIS)

    Sims, C.S.

    1979-05-01

    The fifteenth in the continuing series of Nuclear Accident Dosimetry Intercomparison Studies was held August 14--22, 1978 at the Oak Ridge National Laboratory. The Health Physics Research Reactor, operated in the pulse mode, served as the radiation source. Using different shielding configurations, nuclear accidents with three different neutron and gamma spectra were simulated. Participants from 19 organizations, the most in the history of the studies, exposed dosimeters set up as area monitors as well as dosimeters mounted on phantoms for personnel monitoring. Although many participants performed accurate measurements, the composite dose results, in the majority of cases, failed to meet established nuclear criticality accident dosimetry guidelines which suggest accuracies of +- 25% for neutron dose and +- 20% for gamma dose. This indicates that many participants need to improve their dosimetry systems, their analytical techniques, or both

  19. Intercomparison of radionuclide measurements on marine sediment sample IAEA-300

    Energy Technology Data Exchange (ETDEWEB)

    Ballestra, S; Gastaud, J; Lopez, J J; Parsi, P; Vas, D

    1994-09-01

    The results of an intercomparison exercise on a sediment from Baltic Sea, IAEA-300, designed for the determination of artificial and natural radionuclides' levels, are reported. The data from 159 laboratories representing 51 countries have been evaluated. The following are the recommended values, with confidence intervals, {sup 40}K, {sup 60}Co, {sup 125}Sb, {sup 134}Cs, {sup 137}Cs, {sup 155}Eu, {sup 210}Pb, {sup 210}Po, {sup 228}Ra, {sup 234}U, {sup 238}U, {sup 239+240}Pu and {sup 241}Am. Information values for {sup 54}Mn, {sup 90}Sr, {sup 226}Ra, {sup 228}Th, {sup 230}Th, {sup 232}Th, {sup 235}U and {sup 238}Pu are also reported. All values are given on the reference date of 1 January 1993 and expressed in Bq kg{sup -1} dry weight. (author)

  20. Report on the intercomparison run IAEA-313 Ra-226, Th and U in stream sediment

    International Nuclear Information System (INIS)

    Strachnov, V.; Valkovic, V.; Zeisler, R.; Dekner, R.

    1991-01-01

    This report contains the results of the intercomparison IAEA-313 on the determination of uranium, thorium and Ra-226 in two stream sediments from Indonesia. The participants included 36 laboratories located in 18 countries, and statistical evaluation of their data yield recommended values for these elements. The elements, their recommended values and confidence intervals are: Ra-226, 343 Bq/kg (307-379); Th, 77.1 microg/g (74.8-79.4); U, 18.2 microg/g (17.0-19.3). Tabs

  1. MAX-DOAS formaldehyde slant column measurements during CINDI: intercomparison and analysis improvement

    Directory of Open Access Journals (Sweden)

    G. Pinardi

    2013-01-01

    Full Text Available We present intercomparison results for formaldehyde (HCHO slant column measurements performed during the Cabauw Intercomparison campaign of Nitrogen Dioxide measuring Instruments (CINDI that took place in Cabauw, the Netherlands, in summer 2009. During two months, nine atmospheric research groups simultaneously operated MAX-DOAS (MultiAXis Differential Optical Absorption Spectroscopy instruments of various designs to record UV-visible spectra of scattered sunlight at different elevation angles that were analysed using common retrieval settings. The resulting HCHO data set was found to be highly consistent, the mean difference between instruments generally not exceeding 15% or 7.5 × 1015 molec cm−2, for all viewing elevation angles. Furthermore, a sensitivity analysis was performed to investigate the uncertainties in the HCHO slant column retrieval when varying key input parameters such as the molecular absorption cross sections, correction terms for the Ring effect or the width and position of the fitting interval. This study led to the identification of potentially important sources of errors associated with cross-correlation effects involving the Ring effect, O4, HCHO and BrO cross sections and the DOAS closure polynomial. As a result, a set of updated recommendations was formulated for HCHO slant column retrieval in the 336.5–359 nm wavelength range. To conclude, an error budget is proposed which distinguishes between systematic and random uncertainties. The total systematic error is estimated to be of the order of 20% and is dominated by uncertainties in absorption cross sections and related spectral cross-correlation effects. For a typical integration time of one minute, random uncertainties range between 5 and 30%, depending on the noise level of individual instruments.

  2. Intercomparison of radiation protection devices in a high-energy stray neutron field. Part III: Instrument response

    International Nuclear Information System (INIS)

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernandez, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; Garcia, M.J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, Th.

    2009-01-01

    The European Commission has funded within its 6th Framework Programme a three-year project (2005-2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organizational framework for this project was provided by the European radiation Dosimetry Group EURADOS. Work Package 6 of CONRAD dealt with 'complex mixed radiation fields at workplaces' and in this context it organised a benchmark exercise, which included both measurements and calculations, in a stray radiation field at a high-energy particle accelerator at GSI, Germany. The aim was to intercompare the response of several types of active detectors and passive dosemeters in a well-characterised workplace field. The Monte Carlo simulations of the radiation field and the experimental determination of the neutron spectra with various Bonner Sphere Spectrometers are discussed in Rollet et al. (2008) and in Wiegel et al. (2008). This paper focuses on the intercomparison of the response of the dosemeters in terms of ambient dose equivalent. The paper describes in detail the detectors employed in the experiment, followed by a discussion of the results. A comparison is also made with the H*(10) values predicted by the Monte Carlo simulations and those measured by the BSS systems.

  3. Intercomparison on the measurements of radionuclides in the ceramic brick of China

    International Nuclear Information System (INIS)

    Zhang Jing; Xu Cuihua; Zhang Qing

    2007-01-01

    Objective: To inspect the veracity and reiteration of γ-spectrometry in radioactive measurements. Methods: To be performed by multilateral intercomparison on measurements of radionuclides in two kinds of Chinese ceramic brick samples with γ-spectrometry between laboratories of Japan and of China. Results: The maximum difference of which the values measured by our laboratory related to the total average is 4.21%, and with an equipotent probability of positive and negative difference occurred. These showed that the veracity and reiteration of our measurement system are fine without obviously system errors. Conclusion: It has proved that the quality guarantee system and quality control technology of our γ-spectrum system is perfected and effective up to now. (authors)

  4. Nuclear accident dosimetry measurements at third IAEA intercomparison Vinca, Yugoslavia, May 1973

    International Nuclear Information System (INIS)

    Palfalvi, J.; Makra, S.

    1974-09-01

    Nuclear accident dosimeters from several countries were compared in Vinca, Yugoslavia at an IAEA meeting. The Hungarian Central Research Institute for Physics team performed measurements for the dosimetry of a heavy water assembly which has an escape spectrum significantly differing from the escape spectra of the fast reactors used in previous intercomparisons or from the light water systems used in the Institute. Another problem investigated was the influence of minor spectral differences on the dose determined by activation measurement and spectrum fitting. The importance of sophisticated spectrum calculations was proved. The Vinca irradiations were used for the calibration of the albedo dosimeters of the institute, which are currently applied for personal dosimetry. (K.A.)

  5. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  6. U.S. bioassay Intercomparison Studies Program at Oak Ridge National Lab

    International Nuclear Information System (INIS)

    Payne, G.F.; Bores, N.; Melton, K.K.; Rankin, J.M.

    1998-06-01

    The Intercomparison Studies Program (ISP) for in-vitro bioassay at Oak Ridge National Laboratory (ORNL) has been in place since May 1991. The ISP was originally created to fill a need in the Radiobioassay area at ORNL, specifically in the areas of Quality Control, Quality Assurance, and Performance Testing. In the beginning, this consisted of two or three laboratories working in a pilot intercomparison program. Once it was determined that this could work effectively, the program began to seek additional members to broaden the scope of the effort. The program became formalized with a quarterly report in January 1992. The ISP currently provides cross-check blind/double-blind samples spiked with known amounts of radioactivity to various Department of Energy (DOE) facilities, universities, and private industry organizations throughout the US. These samples can be packaged according to ORNL procedures (ORNL sample bottles, ORNL chain-of-custody forms, tamper seals etc.), for a single blind sample or according to the needs of a particular facility if the double-blind sample mode is to be maintained. In 1998, the customer base was broadened to include European facilities. In January 1993, the whole-body count program was added. This involves each participating facility receiving a block phantom from the ISP and determining a geometry factor using a known standard. At quarterly intervals, each participant receives an unknown sample for analysis. The sample is counted and the data is collected for publication in an annual report. In October 1994, the fecal program was added. This involves spiking an artificial matrix with known amounts of radioactivity. Laboratories receive unknown samples on a quarterly basis. The sample is counted and the data is collected and published in a quarterly report. The ISP maintains archive samples which can be analyzed in the QC laboratory at the request of any participants if a conflict or discrepancy in a sample analysis/result occurs

  7. Intercomparison of delayed neutron summation calculations among JEF2.2, ENDF/B-VI and JNDC-V2

    Energy Technology Data Exchange (ETDEWEB)

    Sagisaka, Mitsuyuki [Nagoya Univ. (Japan); Oyamatsu, K.; Kukita, Y.

    1998-03-01

    We perform intercomparison of delayed neutron activities calculated with JEF2.2, ENDF/B-VI and JNDC-V2 with a simple new method. Significant differences are found at t < 20 (s) for major fissioning systems. The differences are found to stem from fission yields or decay data of several nuclides. The list of these nuclides are also given for the future experimental determination of these nuclear data. (author)

  8. The Scenario Model Intercomparison Project (ScenarioMIP) for CMIP6

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, Brian C.; Tebaldi, Claudia; van Vuuren, Detlef P.; Eyring, Veronika; Friedlingstein, Pierre; Hurtt, George; Knutti, Reto; Kriegler, Elmar; Lamarque, Jean-Francois; Lowe, Jason; Meehl, Gerald A.; Moss, Richard; Riahi, Keywan; Sanderson, Benjamin M.

    2016-01-01

    Projections of future climate change play a fundamental role in improving understanding of the climate system as well as characterizing societal risks and response options. The Scenario Model Intercomparison Project (ScenarioMIP) is the primary activity within Phase 6 of the Coupled Model Intercomparison Project (CMIP6) that will provide multi-model climate projections based on alternative scenarios of future emissions and land use changes produced with integrated assessment models. In this paper, we describe ScenarioMIP's objectives, experimental design, and its relation to other activities within CMIP6. The ScenarioMIP design is one component of a larger scenario process that aims to facilitate a wide range of integrated studies across the climate science, integrated assessment modeling, and impacts, adaptation, and vulnerability communities, and will form an important part of the evidence base in the forthcoming Intergovernmental Panel on Climate Change (IPCC) assessments. At the same time, it will provide the basis for investigating a number of targeted science and policy questions that are especially relevant to scenario-based analysis, including the role of specific forcings such as land use and aerosols, the effect of a peak and decline in forcing, the consequences of scenarios that limit warming to below 2 °C, the relative contributions to uncertainty from scenarios, climate models, and internal variability, and long-term climate system outcomes beyond the 21st century. To serve this wide range of scientific communities and address these questions, a design has been identified consisting of eight alternative 21st century scenarios plus one large initial condition ensemble and a set of long-term extensions, divided into two tiers defined by relative priority. Some of these scenarios will also provide a basis for variants planned to be run in other CMIP6-Endorsed MIPs to investigate questions related to specific forcings. Harmonized, spatially

  9. The Agricultural Model Intercomparison and Improvement Project: Phase I Activities by a Global Community of Science. Chapter 1

    Science.gov (United States)

    Rosenzweig, Cynthia E.; Jones, James W.; Hatfield, Jerry L.; Antle, John M.; Ruane, Alexander C.; Mutter, Carolyn Z.

    2015-01-01

    The Agricultural Model Intercomparison and Improvement Project (AgMIP) was founded in 2010. Its mission is to improve substantially the characterization of world food security as affected by climate variability and change, and to enhance adaptation capacity in both developing and developed countries. The objectives of AgMIP are to: Incorporate state-of-the-art climate, crop/livestock, and agricultural economic model improvements into coordinated multi-model regional and global assessments of future climate impacts and adaptation and other key aspects of the food system. Utilize multiple models, scenarios, locations, crops/livestock, and participants to explore uncertainty and the impact of data and methodological choices. Collaborate with regional experts in agronomy, animal sciences, economics, and climate to build a strong basis for model applications, addressing key climate related questions and sustainable intensification farming systems. Improve scientific and adaptive capacity in modeling for major agricultural regions in the developing and developed world, with a focus on vulnerable regions. Improve agricultural data and enhance data-sharing based on their intercomparison and evaluation using best scientific practices. Develop modeling frameworks to identify and evaluate promising adaptation technologies and policies and to prioritize strategies.

  10. The Cloud Feedback Model Intercomparison Project Observational Simulator Package: Version 2

    Directory of Open Access Journals (Sweden)

    D. J. Swales

    2018-01-01

    Full Text Available The Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP gathers together a collection of observation proxies or satellite simulators that translate model-simulated cloud properties to synthetic observations as would be obtained by a range of satellite observing systems. This paper introduces COSP2, an evolution focusing on more explicit and consistent separation between host model, coupling infrastructure, and individual observing proxies. Revisions also enhance flexibility by allowing for model-specific representation of sub-grid-scale cloudiness, provide greater clarity by clearly separating tasks, support greater use of shared code and data including shared inputs across simulators, and follow more uniform software standards to simplify implementation across a wide range of platforms. The complete package including a testing suite is freely available.

  11. Intercomparison of XH2O Data from the GOSAT TANSO-FTS (TIR and SWIR and Ground-Based FTS Measurements: Impact of the Spatial Variability of XH2O on the Intercomparison

    Directory of Open Access Journals (Sweden)

    Hirofumi Ohyama

    2017-01-01

    Full Text Available Spatial and temporal variability of atmospheric water vapor (H2O is extremely high, and therefore it is difficult to accurately evaluate the measurement precision of H2O data by a simple comparison between the data derived from two different instruments. We determined the measurement precisions of column-averaged dry-air mole fractions of H2O (XH2O retrieved independently from spectral radiances in the thermal infrared (TIR and the short-wavelength infrared (SWIR regions measured using a Thermal And Near-infrared Sensor for carbon Observation-Fourier Transform Spectrometer (TANSO-FTS onboard the Greenhouse gases Observing SATellite (GOSAT, by an intercomparison between the two TANSO-FTS XH2O data products and the ground-based FTS XH2O data. Furthermore, the spatial variability of XH2O was also estimated in the intercomparison process. Mutually coincident XH2O data above land for the period ranging from April 2009 to May 2014 were intercompared with different spatial coincidence criteria. We found that the precisions of the TANSO-FTS TIR and TANSO-FTS SWIR XH2O were 7.3%–7.7% and 3.5%–4.5%, respectively, and that the spatial variability of XH2O was 6.7% within a radius of 50 km and 18.5% within a radius of 200 km. These results demonstrate that, in order to accurately evaluate the measurement precision of XH2O, it is necessary to set more rigorous spatial coincidence criteria or to take into account the spatial variability of XH2O as derived in the present study.

  12. Analysis of SCRM experience in the area of quality assurance for retrospective EPR dosimetry technique with teeth

    International Nuclear Information System (INIS)

    Sholom, S. V.; Chumak, V.V.

    2003-01-01

    EPR dosimetry with tooth enamel is commonly accepted as one of most precise and accurate methods for retrospective dosimetry. At the same time, regularly conducted international Intercomparisons and Inter-calibrations of EPR dosimetry techniques demonstrate the significant scatter of results among laboratories operation in this area. This is mainly caused by the lack of commonly adopted unified technique which would be based on clear and efficient scheme of quality assurance. In the present work we will summarize more than ten-year experience of Scientific Center for Radiation Medicine in the area of EPR dosimetry from the point of view of quality assurance. EPR dosimetry technique with teeth, which was developed and being used in SCRM for routine dosimetry of liquidators is characterized by two-level system of quality assurance. In-house level covers all steps of the technique and allows control and minimizing of uncertainties that arise on separate steps. Extramural level provides the control of reliability and accuracy of technique in whole by means of regular participation in bi- and multi-lateral intercomparisons. Cumulative uncertainty of EPR dosimetry technique determined based on the results of 6 different intercomparisons is 21 mGy for dose below 300 and 11% for dose higher that 300 mGy. (authors)

  13. A dosimetric intercomparison of brachytherapy facilities in Ireland, Scotland and the North of England

    International Nuclear Information System (INIS)

    Heeney, Conor; McClean, Brendan; Kelly, Colin

    2005-01-01

    Background and purpose: A dosimetric intercomparison of brachytherapy remote afterloading units in Ireland, Scotland and the North of England has been carried out involving 9 radiotherapy centres, and sampling 5 HDR and 6 LDR units. Materials and methods: Absolute calibrations have been performed in air on both HDR and LDR sources. The results are expressed in terms of a ratio of local to calibrated value. Frequency distributions were obtained for the multi-source LDR units by individually measuring each source. Using these distributions the effect of non-uniform source strength on the dose rate at Manchester point A was assessed for a typical clinical brachytherapy insertion for carcinoma of the cervix. Both frequency and dose rate distribution curves were modeled using normal statistics and characterised in terms of the mean (μ) and standard deviation (σ). Results: Evaluation of the HDR units indicated a mean ratio of 1.008 (±0.01) while for LDR the mean ratio was 0.997 (±0.02). The LDR frequency distributions demonstrated a variation of σ values extending from 1.4 to 3.0% of μ. It was shown that this non-uniformity in source strength introduced an uncertainty in the treatment planning process of between 0.8 and 1.8% when compared to the assumption of uniform source strength. Conclusions: The results of this intercomparison indicate dosimetric consistency between centres for both LDR and HDR units. The distribution of LDR source strengths were within expected limits and the resultant dose rate distributions were considered clinically acceptable

  14. Report on the intercomparison run IAEA-156 radionuclides in clover

    International Nuclear Information System (INIS)

    Strachnov, V.; Valkovic, V.; Dekner, R.

    1991-01-01

    This report contains the results of the intercomparison IAEA-156 on the determination of radionuclides in clover. Initially participants were requested to determine the levels of 134 Cs, 137 Cs, 40 K, 90 Sr and invited to provide data for other radionuclides. The participants included 46 laboratories located in 25 countries, and statistical evaluation of their data yield recommended values for these four radionuclides. Additional radionuclides reported were 210 Pb, 239 Pu and 125 Sb; however, insufficient data exists to statistically determine recommended values for these radionuclides. The following are the recommended values, with confidence intervals, for the most frequently measured radionuclides (reference date: 1 August 1986): 134 Cs 132.1 Bq/kg (126.4-137.7); 137 Cs 264 Bq/kg (254-274); 40 K 657 Bq/kg (637-676); 90 Sr 14.8 Bq/kg (13.4-16.3). Figs and tabs

  15. Performance of the participant laboratories in the National Intercomparison Program (PNI) in the period from 1991 to 2013

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Vianna, Maria Elizabeth Couto Machado; Oliveira, Antonio Eduardo de; Braganca, Maura Julia Camara da Silva; Ferreira, Ana Cristina de Melo

    2015-01-01

    The statistical evaluation of the data of 23 years of the Brazilian Intercomparison Program shows the performance of the 24 Participant Laboratories of the country in the determination of 29 radionuclides in 10600 spiked samples of low level activity values. The results were shown a good performance and an evolution of the quality control for analyses of this kind of samples in this time period. (author)

  16. Intercomparison of 131I and 99mTc activity measurements in Brazilian nuclear medicine services

    International Nuclear Information System (INIS)

    Iwahara, Akira; De Oliveira, Antonio E.; Tauhata, Luiz; Silva, Carlos J. da; Lopes, Ricardo T.

    2001-01-01

    This work outlines the quality assurance program for the activity measurements of the most used radionuclides at Brazilian Nuclear Medicine Services (NMS). The program aims to guarantee that the patient is given the correct prescribed amount of activity in diagnostic or therapeutic applications. This accurate administration depends upon proper use and calibration of the activity meters by the NMS. Underestimation of administered activity in diagnostic practices could delay correct diagnosis disturbing the value of the investigation. On the other hand, the overestimation would be worse, mainly in therapeutic applications, because an unnecessarily high absorbed dose would be delivered to the patient. The preliminary results of intercomparison for 131 I and 99m Tc showed that many activity meters used at NMS's present problems giving results up to 41% greater than the reference values determined at the National Metrology Laboratory for Ionizing Radiation (LNMRI) which is recognized as the Brazilian authorized metrology laboratory for ionizing radiation. These results have demonstrated that the NMS should improve the accuracy of the activity measurements of the radionuclides administered to the patients and establish the traceability to the national standards of measurements. These standards are based on a pressurized well-type ionization chamber installed at LNMRI and calibrated with reference sources standardized by absolute methods. The protocol of the intercomparison and recommendations made in order to minimize errors in measuring procedures are described and results are discussed

  17. The Cloud Feedback Model Intercomparison Project (CFMIP) contribution to CMIP6.

    Science.gov (United States)

    Webb, Mark J.; Andrews, Timothy; Bodas-Salcedo, Alejandro; Bony, Sandrine; Bretherton, Christopher S.; Chadwick, Robin; Chepfer, Helene; Douville, Herve; Good, Peter; Kay, Jennifer E.; hide

    2017-01-01

    The primary objective of CFMIP is to inform future assessments of cloud feedbacks through improved understanding of cloud-climate feedback mechanisms and better evaluation of cloud processes and cloud feedbacks in climate models. However, the CFMIP approach is also increasingly being used to understand other aspects of climate change, and so a second objective has now been introduced, to improve understanding of circulation, regional-scale precipitation, and non-linear changes. CFMIP is supporting ongoing model inter-comparison activities by coordinating a hierarchy of targeted experiments for CMIP6, along with a set of cloud-related output diagnostics. CFMIP contributes primarily to addressing the CMIP6 questions 'How does the Earth system respond to forcing?' and 'What are the origins and consequences of systematic model biases?' and supports the activities of the WCRP Grand Challenge on Clouds, Circulation and Climate Sensitivity. A compact set of Tier 1 experiments is proposed for CMIP6 to address this question: (1) what are the physical mechanisms underlying the range of cloud feedbacks and cloud adjustments predicted by climate models, and which models have the most credible cloud feedbacks? Additional Tier 2 experiments are proposed to address the following questions. (2) Are cloud feedbacks consistent for climate cooling and warming, and if not, why? (3) How do cloud-radiative effects impact the structure, the strength and the variability of the general atmospheric circulation in present and future climates? (4) How do responses in the climate system due to changes in solar forcing differ from changes due to CO2, and is the response sensitive to the sign of the forcing? (5) To what extent is regional climate change per CO2 doubling state-dependent (non-linear), and why? (6) Are climate feedbacks during the 20th century different to those acting on long-term climate change and climate sensitivity? (7) How do regional climate responses (e.g. in precipitation

  18. Report on the IAEA coordinated research programme on the intercomparison of evaluations of actinide neutron nuclear data

    International Nuclear Information System (INIS)

    Yiftah, S.

    1979-03-01

    Following discussions and Consultants Meeting in 1976, the IAEA, in response to recommendations made formed two coordinated research projects (CRP): one on the Intercomparison of Evaluations of Actinide Neutron Nuclear Data, the other on the Measurement and Evaluation of Transactinium Isotope Nuclear Decay Data. This report covers work done, and to be done, in the framework of the first CRP, as well as some of the practical problems for future work. (B.G.)

  19. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  20. Quantitative determination of bone mineral content (QCT) - intercomparison of computer tomographs of the same construction

    International Nuclear Information System (INIS)

    Andresen, R.; Banzer, D.; Felsenberg, D.; Wolf, K.J.

    1994-01-01

    An intercomparison of 4 CT scanners of the same manufacturer was performed. The bone mineral content of 11 lumbar vertebral columns removed directly post mortem was determined in a specially constructed lucite-water phantom. Even devices of the same construction were shown to yield a variation in the quantitative evaluation markedly exceeding the annual physiological mineral loss. As long as scanner adjustment by physical calibration phantoms has not yet been established, a course assessment and therapy control of bone mineral content should always be carried out on the same QCT scanner. (orig.) [de

  1. Grimsel colloid exercise, an international intercomparison exercise on the sampling and characterization of groundwater colloids

    International Nuclear Information System (INIS)

    Degueldre, C.

    1990-01-01

    The Grimsel colloid exercise was an intercomparison exercise which consisted of an in situ sampling phase followed by a colloid characterization step. The goal of this benchmark exercise, which involved 12 laboratories, was to evaluate both sampling and characterization techniques with emphasis on the colloid specific size distribution. The sampling phase took place at the Grimsel test site between 1 and 13 February 1988 and the participating groups produced colloid samples using various methods. This work was carried out within the Community COCO Club, as a component of the Mirage project (second phase)

  2. Intercomparison of personal dose equivalent measurements by active personal dosimeters. Final report of a joint IAEA-EURADOS project

    International Nuclear Information System (INIS)

    2007-11-01

    Active personal dosimeters (APD) are widely used in many countries, i.e. in the medical field and as operational dosimeters in nuclear power plants. Their use as legal dosimeters is already established in a few countries, and will increase in the near future. In the majority of countries, APDs have not undergone accreditation programmes or intercomparisons. In 2001, an EURADOS (European Radiation Dosimetry Group) Working Group on harmonization of individual monitoring was formed, funded by the European Commission, in the fifth framework programme, and by the participating institutes. The work addressed four issues; inter alia also an inventory of new developments in individual monitoring with an emphasis on the possibilities and performance of active (electronic) dosimeters for both photon/beta and neutron dosimetry. Within the work on this issue, a catalogue of the most extensively used active personal dosimeters (APDs) suitable for individual monitoring was made. On the basis of the knowledge gained in this activity, the organization of an international intercomparison, which would address APDs, was considered of great value to the dosimetric community. The IAEA in cooperation with EURADOS organized such an intercomparison in which most of the testing criteria as described in two internationally accepted standards (IEC61526 and IEC61283) were used. Additionally, simulated workplace fields were used for testing the APD reactions to pulsed X ray fields and mixed gamma/X ray fields. This is the first time that results of comparisons of such types are published, which is of great importance for APD end users in medical diagnostic and surgery X ray applications. Nine suppliers from six countries in Europe and the USA participated in the intercomparison with 13 different models. One of the models was a special design for extremity dose measurements. Irradiations and readout was done by two accredited calibration laboratories in Belgium and France and the French

  3. Report on intercomparison A-13 of the determination of trace elements in freeze dried animal blood

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1983-03-01

    This document deals with the comparative evaluation of the analytical data on the trace elements in beef blood obtained by 38 laboratories in 23 countries. The evaluations were based on 799 laboratory mean values of concentration of 41 elements. It was one of the series of IAEA intercomparisons on the determination of trace elements in animal materials. It was organized for the purpose of assisting the participating laboratories to check the accuracy of their work and to prepare a new reference material

  4. Report on the intercomparison run for the determination of radionuclides in soils. IAEA-326 and IAEA-327

    International Nuclear Information System (INIS)

    Bojanowski, R.; Radecki, Z.; Campbell, M.J.; Burns, K.I.; Trinkl, A.

    2001-04-01

    Intercomparison programmes have the potential to improve the level of agreement between the results of measurements obtained on natural matrices by different methods and by various laboratories world-wide. They could also be able to help the participants trace the causes of departure of their data from the true values, if sufficient information is provided to the organiser. As the true values are unknown, they are usually replaced by consensus values derived from the data that have met a number of defined quality criteria. The previous evaluation process of intercomparison exercises did not allow the full benefits of exercise to be obtained. The reference values were set on the basis of 'the law of the majority' ('consensus' values) and were not traceable to internationally agreed primary units (SI units). Traceability of measurements can be achieved by providing a link between the data generated in participants' laboratories and a stipulated reference point through an unbroken chain of comparisons, enabling assessment of the quality of their measurements by quantifying the combined uncertainty of all the links in the chain. In radioactivity measurements, the shortest chain is achieved in γ-spectrometry. It can be obtained by proper calibration of instruments, using standard sources certified by primary measurement laboratories and propagating the uncertainties throughout the whole measurement process. Matrix effects and coincidence losses must be given due attention as well. Traceability of results obtained by isotope dilution alpha- spectrometry requires, in addition, a quantitative budget of uncertainties associated with sample treatment up to the stage when isotope exchange is assured. The most difficult cases are methods based on beta counting because each stage of the numerous analytical operations can break the traceability chain and because beta-radiation has a continuous spectrum which is difficult to quantify. In this Intercomparison, an attempt was made

  5. The NASA Reanalysis Ensemble Service - Advanced Capabilities for Integrated Reanalysis Access and Intercomparison

    Science.gov (United States)

    Tamkin, G.; Schnase, J. L.; Duffy, D.; Li, J.; Strong, S.; Thompson, J. H.

    2017-12-01

    NASA's efforts to advance climate analytics-as-a-service are making new capabilities available to the research community: (1) A full-featured Reanalysis Ensemble Service (RES) comprising monthly means data from multiple reanalysis data sets, accessible through an enhanced set of extraction, analytic, arithmetic, and intercomparison operations. The operations are made accessible through NASA's climate data analytics Web services and our client-side Climate Data Services Python library, CDSlib; (2) A cloud-based, high-performance Virtual Real-Time Analytics Testbed supporting a select set of climate variables. This near real-time capability enables advanced technologies like Spark and Hadoop-based MapReduce analytics over native NetCDF files; and (3) A WPS-compliant Web service interface to our climate data analytics service that will enable greater interoperability with next-generation systems such as ESGF. The Reanalysis Ensemble Service includes the following: - New API that supports full temporal, spatial, and grid-based resolution services with sample queries - A Docker-ready RES application to deploy across platforms - Extended capabilities that enable single- and multiple reanalysis area average, vertical average, re-gridding, standard deviation, and ensemble averages - Convenient, one-stop shopping for commonly used data products from multiple reanalyses including basic sub-setting and arithmetic operations (e.g., avg, sum, max, min, var, count, anomaly) - Full support for the MERRA-2 reanalysis dataset in addition to, ECMWF ERA-Interim, NCEP CFSR, JMA JRA-55 and NOAA/ESRL 20CR… - A Jupyter notebook-based distribution mechanism designed for client use cases that combines CDSlib documentation with interactive scenarios and personalized project management - Supporting analytic services for NASA GMAO Forward Processing datasets - Basic uncertainty quantification services that combine heterogeneous ensemble products with comparative observational products (e

  6. Report of the Intercomparison program by thermoluminescent dosimetry for Secondary Standard Dosimetry Laboratories

    International Nuclear Information System (INIS)

    Papadopulos, Susana

    2000-01-01

    In this report the results of an intercomparison program within a research coordinated program are presented. This is a third phase of the study that consisted in to evaluate the implementation of the new ICRU quantities for individual monitoring by the SSDLs, their capabilities to perform irradiations in different angles and the interpretation of the standard ISO 4370-3. This phase as well the first one was coordinated by Argentina through the Autoridad Regulatoria Nuclear that verified the performance of the participant laboratories. The SSDL of Argentina calibrated the dosimetric system to be used, and sent a set of tld dosimeters for irradiation at the SSDL or dosimetry laboratories of nine countries of latin america

  7. Tenth ORNL Personnel Dosimetry Intercomparison Study

    International Nuclear Information System (INIS)

    Swaja, R.E.; Chou, T.L.; Sims, C.S.; Greene, R.T.

    1985-03-01

    The Tenth Personnel Dosimetry Intercomparison Study was conducted at the Oak Ridge National Laboratory during April 9-11, 1984. Dosemeter badges from 31 participating organizations were mounted on 40cm Lucite phantoms and exposed to a range of dose equivalents which could be encountered during routine personnel monitoring in mixed radiation fields. The Health Physics Research Reactor served as the only source of radiation for eight of the ten irradiations which included a low (approx. 0.50 mSv) and high (approx. 10.00 mSv) neutron dose equivalent run for each of four shield conditions. Two irradiations were also conducted for which concrete- and Lucite-shield reactor irradiations were gamma-enhanced using a 137 Cs source. Results indicated that some participants had difficulty obtaining measurable indication of neutron and gamma exposures at dose equivalents less than about 0.50 mSv and 0.20 mSv, respectively. Albedo dosemeters provided the best overall accuracy and precision for the neutron measurements. Direct interaction TLD systems showed significant variation in accuracy with incident spectrum, and threshold neutron dosemeters (film and recoil track) underestimated reference values by more than 50%. Gamma dose equivalents estimated in the mixed fields were higher than reference values with TL gamma dosemeters generally yielding more accurate results than film. Under the conditions of this study in which participants had information concerning exposure conditions and radiation field characteristics prior to dosemeter evaluation, only slightly more than half of all reported results met regulatory standards for neutron and gamma accuracy. 19 refs., 2 figs., 29 tabs

  8. AQCS 1990. Intercomparison runs, reference materials

    International Nuclear Information System (INIS)

    1990-01-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the International Atomic Energy Agency (Agency) is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. Such a control is necessary since results of analytical activities may be the basis upon which economic, administrative, medical or legal decisions are taken; they must, therefore, be documented to be sufficiently reliable. The Agency has instituted the AQCS-programme which for 1990 will involve distributing samples for Intercomparison Runs and Reference Materials in a way similar to that of previous years. The Agency's Analytical Quality Control Services (AQCS) programme provides mainly three types of materials: materials which can be used in analytical laboratories working in the fields of nuclear technology and isotope hydrology. These include uranium ore Reference Materials and other substances of interest for nuclear fuel technology as well as stable isotope Reference Materials for mass spectrometric determination of isotope ratios in natural waters; materials with known content of uranium, thorium and/or transuranium elements or fission products for the determination of environmental radioactivity or control of nuclear safety; materials for use in the determination of stable trace elements in environmental, biomedical and marine research. Radiochemical methods such as neutron activation or isotope dilution analysis are often used in the determination of such trace elements and constitute an important contribution of nuclear techniques to applied science. Tabs

  9. Visible light nitrogen dioxide spectrophotometer intercomparison: Mount Kobau, British Columbia, July 28 to August 10, 1991

    Science.gov (United States)

    Mcelroy, C. T.; Elokhov, A. S.; Elansky, N.; Frank, H.; Johnston, P.; Kerr, J. B.

    1994-01-01

    Under the auspices of the World Meteorological Organization, Environment Canada hosted an international comparison of visible light spectrophotometers at Mt. Kobau, British Columbia in August of 1991. Instruments from four countries were involved. The intercomparison results have indicated that some significant differences exist in the responses of the various instruments, and have provided a basis for the comparison of the historical data sets which currently exist as a result of the independent researches carried out in the past in the former Soviet Union, New Zealand, and Canada.

  10. Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Science.gov (United States)

    Hansen, R. F.; Blocquet, M.; Schoemaecker, C.; Léonardis, T.; Locoge, N.; Fittschen, C.; Hanoune, B.; Stevens, P. S.; Sinha, V.; Dusanter, S.

    2015-10-01

    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios

  11. World-wide intercomparison exercise for the determination of trace elements in Fucus sample IAEA-140. Report no. 64

    International Nuclear Information System (INIS)

    Coquery, M.; Carvalho, F.P.; Horvat, M.; Azemard, S.

    1997-09-01

    The accurate and precise determination of trace elements in marine samples is fundamental to pollution assessment in coastal and marine environments. Analyses of sea plants are important to investigate the uptake of toxic elements along the trophic chain and sea plants may be used as indicators for water pollution and to compare the levels of contamination of different aquatic environments. IAEA. together with UNEP and the Intergovernmental Oceanographic Commission (IOC) work closely with other producers of Reference Materials in order to assure a continuous supply of these vital compounds for quality assurance procedures. A full catalogue of materials is published regularly. The Marine Environmental Studies Laboratory (MESL) of IAEA-MEL has conducted intercomparison exercises on trace elements for over twenty years as part of its contribution to IAEA's Analytical Quality Control Service, UNEP's Regional Seas Programme. and, occasionally, in association with the IOC GIPME (Global Investigation of the Pollution in the Marine Environment) programme. This report describes the performance of laboratories in one intercomparison run conducted during 1996 that was organized for the determination of trace elements in a marine macro algae (Fucus sp.) sample. This study was intended to give laboratories responsible for trace element analyses of marine materials an opportunity for checking their analytical performance

  12. Intercomparison of JAERI Torso Phantom lung sets

    International Nuclear Information System (INIS)

    Kramer, Gary H.; Hauck, Barry M.

    2000-01-01

    During the course of an IAEA sponsored In Vivo intercomparison using the JAERI phantom the Human Monitoring Laboratory was able to intercompare thirteen lung sets made by three suppliers. One set consisted of sliced lungs with planar inserts containing different radionuclides. The others consisted of whole lung sets with the activity homogeneously distributed throughout the tissue substitute material. Radionuclides in the study were: natural uranium, 3% enriched uranium, 241 Am, 238 Pu, 239 Pu, 152 Eu, and 232 Th Except for the 241 Am (59.5 keV) and occasionally one of the 232 Th (209 keV) photopeaks, the lung sets that had radioactivity homogeneously distributed throughout the tissue equivalent lung tissue material showed good agreement. The 241 Am lung set gave a counting efficiency that appeared 25% too high for all overlay plate configurations. This was observed by other participants. It exemplifies that the manufacture of tissue substitute lung sets is still something of a black art. Despite all precautions, this lung set is either inhomogeneous or has had the wrong activity added. Heterogeneity can lead to an error in the activity estimate of a factor of three if the activity was severely localised due to improper mixing. A factor of 1.25, which appears to be the discrepancy, could easily be explained in this way. It will not be known for some time, however, what the true reason is as the participants are still waiting for the destructive analysis of this lung set to determine the 'true' activity. The sliced lungs ( 241 Am, 152 Eu, and U-nat) manufactured by the Human Monitoring Laboratory are in excellent agreement with the other lung sets. The advantages of sliced lung sets and planar sources are manifold. Activity can be distributed in a known and reproducible manner to mimic either a homogeneous or heterogeneous distribution in the lung. Short lived radionuclides can be used. Cost is much less than purchasing or manufacturing lung sets that have the

  13. The PSACOIN level 1B exercise: A probabilistic code intercomparison involving a four compartment biosphere model

    International Nuclear Information System (INIS)

    Klos, R.A.; Sinclair, J.E.; Torres, C.; Mobbs, S.F.; Galson, D.A.

    1991-01-01

    The probabilistic Systems Assessment Code (PSAC) User Group of the OECD Nuclear Energy Agency has organised a series of code intercomparison studies of relevance to the performance assessment of underground repositories for radioactive wastes - known collectively by the name PSACOIN. The latest of these to be undertaken is designated PSACOIN Level 1b, and the case specification provides a complete assessment model of the behaviour of radionuclides following release into the biosphere. PSACOIN Level 1b differs from other biosphere oriented intercomparison exercises in that individual dose is the end point of the calculations as opposed to any other intermediate quantity. The PSACOIN Level 1b case specification describes a simple source term which is used to simulate the release of activity to the biosphere from certain types of near surface waste repository, the transport of radionuclides through the biosphere and their eventual uptake by humankind. The biosphere sub model comprises 4 compartments representing top and deep soil layers, river water and river sediment. The transport of radionuclides between the physical compartments is described by ten transfer coefficients and doses to humankind arise from the simultaneous consumption of water, fish, meat, milk, and grain as well as from dust inhalation and external γ-irradiation. The parameters of the exposure pathway sub model are chosen to be representative of an individual living in a small agrarian community. (13 refs., 3 figs., 2 tabs.)

  14. Intercomparisons to evaluate the suitability of gaschromatographic, electron-spin-resonance spectrometric and thermoluminescence methods to detect irradiated foods in routine control

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Spiegelberg, A.; Linke, B.; Wagner, U.; Boegl, K.W.

    1993-01-01

    The results of four different intercomparisons to detect irradiated fish and chicken meat containing bones, chicken-, pork-, and beef-meat without bones, spices, herbs as well as spice- and herb mixtures, various fruit and vegetables as well as pistachio nuts using gas chromatographic methods, electron-spin resonance spectroscopy or thermoluminescence analyses are reported. (author)

  15. Psacoin level 1A intercomparison probabilistic system assessment code (PSAC) user group

    International Nuclear Information System (INIS)

    Nies, A.; Laurens, J.M.; Galson, D.A.; Webster, S.

    1990-01-01

    This report describes an international code intercomparison exercise conducted by the NEA Probabilistic System Assessment Code (PSAC) User Group. The PSACOIN Level 1A exercise is the third of a series designed to contribute to the verification of probabilistic codes that may be used in assessing the safety of radioactive waste disposal systems or concepts. Level 1A is based on a more realistic system model than that used in the two previous exercises, and involves deep geological disposal concepts with a relatively complex structure of the repository vault. The report compares results and draws conclusions with regard to the use of different modelling approaches and the possible importance to safety of various processes within and around a deep geological repository. In particular, the relative significance of model uncertainty and data variability is discussed

  16. Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms

    International Nuclear Information System (INIS)

    Dimbylow, Peter J; Hirata, Akimasa; Nagaoka, Tomoaki

    2008-01-01

    This paper provides an intercomparison of the HPA male and female models, NORMAN and NAOMI with the National Institute of Information and Communications Technology (NICT) male and female models, TARO and HANAKO. The calculations of the whole-body SAR in these four phantoms were performed at the HPA, at NICT and at the Nagoya Institute of Technology (NIT). These were for a plane wave with a vertically aligned electric field incident upon the front of the body from 30 MHz to 3 GHz for isolated conditions. As well as investigating the general differences through this frequency range, particular emphasis was placed on the assumptions of how dielectric properties are assigned to tissues (particularly skin and fat) and the consequence of using different algorithms for calculating SAR at the higher frequencies.

  17. Results and recommendations from an intercomparison of six Hygroscopicity-TDMA systems

    Directory of Open Access Journals (Sweden)

    A. Massling

    2011-03-01

    Full Text Available The performance of six custom-built Hygrocopicity-Tandem Differential Mobility Analyser (H-TDMA systems was investigated in the frame of an international calibration and intercomparison workshop held in Leipzig, February 2006. The goal of the workshop was to harmonise H-TDMA measurements and develop recommendations for atmospheric measurements and their data evaluation. The H-TDMA systems were compared in terms of the sizing of dry particles, relative humidity (RH uncertainty, and consistency in determination of number fractions of different hygroscopic particle groups. The experiments were performed in an air-conditioned laboratory using ammonium sulphate particles or an external mixture of ammonium sulphate and soot particles.

    The sizing of dry particles of the six H-TDMA systems was within 0.2 to 4.2% of the selected particle diameter depending on investigated size and individual system. Measurements of ammonium sulphate aerosol found deviations equivalent to 4.5% RH from the set point of 90% RH compared to results from previous experiments in the literature. Evaluation of the number fraction of particles within the clearly separated growth factor modes of a laboratory generated externally mixed aerosol was done. The data from the H-TDMAs was analysed with a single fitting routine to investigate differences caused by the different data evaluation procedures used for each H-TDMA. The differences between the H-TDMAs were reduced from +12/−13% to +8/−6% when the same analysis routine was applied. We conclude that a common data evaluation procedure to determine number fractions of externally mixed aerosols will improve the comparability of H-TDMA measurements.

    It is recommended to ensure proper calibration of all flow, temperature and RH sensors in the systems. It is most important to thermally insulate the aerosol humidification unit and the second DMA and to monitor these temperatures to an accuracy of 0.2 °C. For the

  18. A practical intercomparison of non-radiometric methods for the determination of low levels of radionuclides

    International Nuclear Information System (INIS)

    McMahon, A.W.

    1991-01-01

    Non-Radiometric, methods of elemental analysis have been assessed as alternatives to radiometric methods for the determination of low levels of radionuclides. The methods have been assessed in a practical intercomparison, using a set of samples containing known, low levels of analytes in a variety of matrices. It was found that all of the methods considered have a role to play and are to some extent complementary in terms of cost, rate of sample throughput, elemental coverage, imaging capability sensitivity and quantitative capabilities. Techniques based on mass spectrometry have most to offer in this application, allowing sensitive isotope specific determinations. (author)

  19. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  20. An intercomparison on radionuclides in environmental samples, Baltic-Danish co-operation project on radiation protection 2001-2003

    DEFF Research Database (Denmark)

    Nielsen, S.P.

    2004-01-01

    Sixteen laboratories participated in an intercomparison exercise carried out in 2003 on laboratory analyses of radionuclides in environmental samples. The sample types included seawater, lake water, soil, dry milk and seaweed and the exercise involved theradionuclides 137Cs, 90Sr, 60Co, 239, 240Pu...... laboratories passed the evaluation tests. The results indicate that for several of the laboratories there isroom to improve the analytical quality on radionuclides in environmental samples to match an uncertainty corresponding to a relative standard deviation of 10%....